Loading...
HomeMy WebLinkAbout40572-Z ,,f-�OS��F�1'' G Town of Southold 4/28/2016 4 t` f� P.O.Box 1179 co 53095 Main Rd ,.y4ol ._. Southold, New York 11971 rr CERTIFICATE OF OCCUPANCY No: 38272 Date: 4/28/2016 THIS CERTIFIES that the building ELECTRICAL Location of Property: 19725 Soundview Ave, Southold SCTM#: 473889 Sec/Block/Lot: 51.-4-1 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 3/29/2016 pursuant to which Building Permit No. 40572 dated 3/29/2016 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: REMOVED ANY DEFECTS OF ORIGINAL INSTALLATION OF GENERATOR, ALSO INSTALLED NEW AUTOMATIC TRANSFER SWITCH OF STAND-BY GENERATOR The certificate is issued to Stanisic,Maria of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 40572 04-13-16 PLUMBERS CERTIFICATION DATED � / Authorized Signature TOWN OF SOUTHOLD (0, 404` BUILDING DEPARTMENT TOWN CLERK'S OFFICE cn oy� �o� r� SOUTHOLD, NY . oc,� y,,,, BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 40572 Date: 3/29/2016 Permission is hereby granted to: Stanisic, Maria PO BOX 1453 Southold, NY 11971 To: re-install 200 ats & removal of generator electrical violations At premises located at: 19725 Soundview Ave, Southold SCTM # 473889 Sec/Block/Lot# 51.-4-1 Pursuant to application dated 3/29/2016 and approved by the Building Inspector. To expire on 9/28/2017. Fees: ELECTRIC $85.00 Total: $85.00 Bu •ing In ctor /,,�# iii..„� Town Hall Annex �� (® : Telephone(631)765-1802 54375 Main Road i 411 illg Fax(631)765-9502 P.O.Box 1179 11 Q 0 roger.richertRtown.southold.ny.us Southold,NY 11971-0959 . 'i t !a... 'iii BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION Issued To: Stanisic Address: 19725 Soundview Avenue City: Southold St: New York Zip: 11971 Building Permit#: 40572 Section 51 Block: 4 Lot: 1 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: Ocean Electric Corp. License No: 4015-E SITE DETAILS Office Use Only Residential X Indoor X Basement X Service Only Commerical Outdoor X 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures HID Fixtures Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel NC Condenser Single Recpt - Recessed Fixtures CO Detectors Sub Panel NC Blower Range Recpt Fluorescent Fixture Pumps Transformer Appliances Dryer Recpt Emergency Fixtures Time Clocks Disconnect Switches Twist Lock Exit Fixtures TVSS Other Equipment: Install New Automatic Transfer Switch for Existing Standby Generator. Removed Defects in Original Generator Installation List of Repairs on File in Building Department. Notes: Inspector Signature: Date: 13-Apr-16 Electrical 81 Compliance Form.xls �,41 OW S01/7 _ '` �f . 4 Town Hall Annex : * . ` + ; Telephone(631)765-1802 54375 Main Road g Q2 P.O.Box 1179 ; `n Q t tOwnn s $ rooer_richerou hold.nv.us Southold,NY 11971-0959 %t`404 y0��► i BUILDING DEPARTMENT TOWN OF SOUTHOLD APPLICATION FOR ELECTRICAL INSPECTION REQUESTED BY: l , nv G�\Z_ Date: -00-1 Co Company Name: c.,_ - ,(-\Name: License No.: �-l�I�� Address: S� \ _ 3Ct A- Phone No.: , n.31- -� - . __ ; .. � � r. _ '�' , /� I 16(�r �8� (0o(eQ JOBSITE INFORMATION: (*Indicates required information) *Name: '(`( C CA (,(1 Ls *Address: 1 2 2 a___ ��A A�(-e ,..S„--)0,N,-\N,1 A. r *Cross Street: _y-,,--v. ? r )I -1r\ &. Gyn,,b\,-s 2- -- \ *Phone No.: Permit No.: Tax-Map District: 1000 . Section: 51 Block: Li Lot: I *BRIEF*BDESCRIPTION OF WORK(Please Print Clearly) • i Ie____:„(NS)-c,1,1 0 ,AXD_ 'Pr-N- siC Oct\ 0Z§r C) sc -r .6-1 _C---,\,f"c4 I \r;k))ya. ‘.s (Please Circle All That Apply) *Is job ready for inspection: ca/, NO Rough In Final *Do you need a Temp Certificate: - YES/(W) -- • -- Temp Information (If.needed) *Service Size: 1 Phase 3Phase 100 150 200 300 350 400 Other *New Service: Re-connectUndergroun Number of Meters Change of Service Overhead Additional Information: PAYMENT DUE WITH APPLICATION - � � cp-----scp0,� 82-Request for Inspection Form _ ��1 04-12-'16 14:52 FROM- Ocean Electric 6312870731 T-206 P0001/0003 F-709 LEAN ELECTRIC CORP. Memo: April 12, 2016 Attention: Mr. Roger Richert Southold Town Electrical Inspector Please give the following 3-page fax to Mr. Roger Richert Mr. Richert, the following is a description of the emergency generator electrical repair work that was accomplished at Ms. Maria Stanisic's Southold home; as per her request the original letter has been sent to Ms. S#anisic. If you may have any questions or need us on-site for the inspection please feel free to call me at 631-237-6060 Sincerely, 1� It1) 4411!"/Z, _7),d Steven C. Schaefer AP Operations Manager 158 County Road 39, Suite 6, Southampton, NY 11968 • (631) 287-6060 • Fax (631) 287-0731 www.@OceanElectric.net I U 04-12-'16 14:52 FROM- Ocean Electric 6312870731 T-206 P0002/0003 F-709 CEAN ELECTRIC CORP. ,,_, March, 21, 2016 Ms. Maria Stanisic P.O. Box 1453, Southold, New York 11971 Job Site: Stanisic residence 19725 Soundview Avenue, Southold, New York 11971 Ref: Violation Repairs/ replacement of ATS Dear Ms. Stanisic, The following letter is to list the following violations that were repaired at your home and the replacement of the Automatic Transfer Switch (ATS) to match the wiring utilized by others. Ocean Electric Corp. was called to the Stanisic residence on 2-25-16 at the above address for an electrical outage and the generator not running. A kohier factory trained Technician was dispatched to the location to troubleshoot the downed generator. Upon arrival he found the following: • Normal Utility Power was still out in the neighborhood. • Generator was in the ready mode but didn't start or transfer power to emergency. Our Technician checked out the generator and found it to be in working order.' He also checked the ATS and found the following: • The wiring used for the start stop landed on the RBUS connector was UF (direct burial copper wire) which would've been acceptable if the previous installer had used an RDT type Kohler ATS but not correct for an RXT switch. • Our Technician tried to attempt to Temp-out the transfer switch using the proper control wire above ground from the transfer switch to the generator (roughly 400 feet) but couldn't because the wrong wire had burned out the control board within the current switch making it impossible without him having a replacement board to temp the switch out. During our troubleshooting efforts the Utility Power had returned to the residence. • Proper control wire for the RXT switch is Beldon shielded twisted pair stranded copper wire. To offer a repair to Ms. Stanisic we needed to do further investigation into the previously installed generator and ATS. • From a cost savings perspective it will be less expensive to change the existing RXT switch and re-install an RDT switch and use the current control wire. Beldon wire isn't direct burial so trenching and a conduit from generator to house penetration would've been required if we were to save the existing RXT switch making the RDT a more cost effective solution. 158 County Road 39, Suite 6, Southampton, NY 11968 • (631) 287-6060 • Fax (631) 287-0731 p ..7,,- 2 ( www.@OceanElectric.net Qo� ‘ – 04-12-'16 14:52 FROM- Ocean Electric 6312870731 T-206 PO003/0003 F-709 Investigation also found the following "Electrical Violations" that were directly tied to the current generator system installation: • 2/3 direct burial Tray Cable was used as a feed for the generator to ATS. By electrical code the Tray cable must not enter the residence more than 5 feet; anything over 5-feet must transition to an approved wire, splices and splice box. We removed twenty-five (25) extra feet of Tray cable and consequently replaced with the proper wire, splices and splice box. • We also removed 25 1- feet of UF direct burial wire which was used for control circuitry and battery charger and replaced with the approved wire. • At this point we pulled the disconnect and main panel cover and found more violations: o Neutrals and grounds are to be separated in the main panel when you use a whole house disconnect/generator system they weren't and we rectified the situation by accomplishing the separation of same. o Previous installer used the main panel, disconnect and ATS as raceways for Line and Load wiring also a code violation. Fused and unfused wires can-not run in same conduits and or raceways; they must be separated. o Line voltage from the street came into the main service panel and was spliced with underground Polaris splices and extended through the panel, into and through the disconnect switch and ATS; a code violation. To keep the cost down to a minimum Ocean Electric accomplished the following: • Removed the RXT switch and added an RDT. • Removed the line voltage wire from the top of the main service panel and added an outdoor splice box just west of the front door and extended the feed to meet the existing 200 amp fused disconnect that we moved adjacent to,the main service panel. • Installed a new RDT-CFNA-0200A ATS adjacent to the Fused disconnect and wired with new line and load side feeders to the fused disconnect and panel. • Added a splice box on the east side of the basement to intercept the 2/3 Tray cable and the 12UF underground copper Wire. Toned-out UF wires, marked and spliced the 2/3 Romex to the Tray and two of the three 12-3 UF's to the 12 Romex wires (the third was capped off and left in the box as a spare). Routed the required line and low voltage wires to the ATS and connected same. • Added ground bars and separated neutrals and grounds per electrical code. • Run tested and accomplish a home transfer and shut-down to test the system. See also repair contract written prior to accomplishment of the repair. Sincerely, 4 r / f O,� Steven C. Schaefer r. Operations Manager - 158 County Road 39, Suite 6, Southampton, New York 11968 • (631) 287-6060 • Fax (631) 287-0731 www.OceanElectric.net6-6