Loading...
HomeMy WebLinkAbout38255-Z ,,�4g�FP t,�'4 , Town of Southold 5/5/2016 4 - fi �` il P.O.Box 1179 53095 Main Rd r24, �4.7 Southold,New York 11971 '+'add # �a �, CERTIFICATE OF OCCUPANCY No: 38295 Date: 5/5/2016 THIS CERTIFIES that the building GENERATOR Location of Property: 230 Eastwood Dr, Cutchogue SCTM#: 473889 Sec/Block/Lot: 110.-3-15 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 8/2/2013 pursuant to which Building Permit No. 38255 dated 8/15/2013 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: ACCESSORY GENERATOR AS APPLIED FOR The certificate is issued to Geehreng,Robert&Geehreng, Josephine of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 38255 10-31-2013 PLUMBERS CERTIFICATION DATED Authorized Signature vi ur TOWN OF SOUTHOLD 0. ' BUILDING DEPARTMENT TOWN CLERK'S OFFICE l%04„ cf. ; SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 38255 Date: 8/15/2013 Permission is hereby granted to: Geehreng, Robert & Geehreng, Josephine PO BOX 466 Cutchogue, NY 11935 To: install an accessory generator as applied for At premises located at: 230 Eastwood Dr, Cutchogue SCTM # 473889 Sec/Block/Lot# 110.-3-15 Pursuant to application dated 8/2/2013 and approved by the Building Inspector. To expire on 2/14/2015. Fees: ACCESSORY $100.00 CO -ACCESSORY BUILDING $50.00 Total: $150.00 /4/A- :__ i'`i-,e(---. Building Inspector Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings, property lines,streets,and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal (S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1%lead. 5. Commercial building,industrial building, multiple residences and similar buildings and installations,a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings (prior to April 9, 1957) non-conforming uses,or buildings and"pre-existing" land uses: 1. Accurate survey of property showing all property lines,streets, building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant.If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00,Alterations to dwelling$50.00, Swimming pool$50.00,Accessory building$50.00,Additions to accessory building$50.00,Businesses$50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of.Certificate of Occupancy-$_25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy-Residential $15.00, Commercial$15.00 Date. New Construction: Old or Pre-existing Building: (check one) Location of Property: - � �� �� � rh'� -- House No. ,,(� Street Harr1 t Owner or Owners of Property: 1 --e.e {CAI Suffolk County Tax Map No 1000, Section 10 Block .3 Lot I Subdivision Filed Map. Lot: Permit No. Date of Permit. Applicant: Health Dept. Approval: Underwriters Approval: Planning Board Approval: Request for: Temporary Certificate Final Certificate: (check one) Fee Submitted:$ Applicant Signature �o, % SO!/rir® Town Hall Annex ,�� ~® �® : Telephone(631)765-1802 54375 Main Road i ; Fax(631)765-9502 P.O.sox 1179 ; c 1��` roger.richert(a�town.southold.ny.us Southold,NY 11971-0959 . 4 a i i • =l`�COUNT`i3O,1 -—.... F BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION Issued To: Robert Geehreng Address: 230 Eastwood Dr City: Cutchogue St: NY Zip: 11935 Building Permit#: 38255 Section: 1 10 Block: 3 Lot: 15 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: Glens Electric License No: 4770-me SITE DETAILS Office Use Only Residential X Indoor X Basement Service Only Commerical Outdoor X 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures HID Fixtures Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Fluorescent Fixture Pumps Transformer Appliances Dryer Recpt Emergency Fixtures Time Clocks Disconnect Switches Twist Lock Exit Fixtures TVSS Other Equipment: 14KW stand by generator to include 100a transfer switch Notes: Inspector Signature: '. 1.4/1 «�%. Date: Oct 31 2013 I' 81-Cert Electrical Compliance Form.xls ,./A-Y of,„ 4% r Q)/ At iig V ,1 6 8 TOWN OF SOUTHOLD BUILDING DEPT. 0" 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) x ELECTRICAL (FINAL) REMARKS: 6-T,W-L.g-e-C,- .6 / DATE 7 3t (terINSP ECT OR A dry FIELD INSPECTION REPORT 1 DATE COMMENTS .. (A1 00 00 ' FOUNDAON(ZST) • \ 44 • FOUNDATION((ND) g • C) i • ROUGH FRAMING& PLUNISING • • - .. . • . . ; ]I SULATION PER N.Y. • • H STATE ENERGY CODE • ' • • • • . 7 J _ .. -- G • n Z • G FINAL Z, • 40y-* 8.3 S'-5�a ADDITIONAL COMMENTS eoci-i;re J.-ri-- Zit(,./P ie p., ,. ela `;1-- f-.1.,,..--12..,e-4,r ( I-(4,1/!-e. £-c — &'c . i ' (( ' . cts' 0 . . 23 • . 1.4 • , ' " • 9-': . H. : : Ul 3 . , . Z__?,, • • . • r • • TOWN-OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL _ , , . Board of Health SOUTHOLD, NY 11971 • - • • 4 sets of Building Plans TEL: (631) 765-1802 Planning Board approval FAX: (631) 765-9502 .-...., Survey SoutholdTown.NorthFork.net PERMIT NO. (--- 4?- --8----6 Check !, Septic Form N.Y.S.D.E,C. Trustees C.O.Application i 3 Flood Permit Examined_________g ,20 l Single&Separate Storm-Water Assessment Form Contact: Approved /'S ,20) Mail to: Disapproved a/c , Phone:&3/- ?�.- bsi/ Expiration /�,,20 (6 ,6,,,ex>V E 0 D _ ' Building Inspector AUG - 2 2013 PPLICATION FOR BUILDING PERMIT BLDG.DEPT. Date - , 20 TOWN OF SOUTHOLD INSTRUCTIONS a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans, accurate plot plan to scale. Fee according to schedule. b. Plot plan showing location of lot and of buildings on premises, relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. " f. Every building permit shall expire if the work authorized has not commenced within 12;months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize, in writing,the extension of the permit for an addition six months. Thereafter, a new permit shall be required. -, APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York,and other applicable Laws, Ordinances or Regulations, for the construction of buildings,additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances,building code,housing code,and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. , OCCUPANCY - US (Sign/e of applicant or name, if a corporation) �p IS UNLAWFUL, s ol.�oX/moo.. / c`.c` Tr- i� ( ail n_ cant) i" \,,,, ,,,A , a .. t i ,,V DATE' / / 3 3--°-'3-3-' whether applicant is owner, lessee, agent, architect, engineer, general contr ctor, e e h pian p` °•`. builder FEE NOTIFY BUILDING; DEPARTMENT AT 7654802 8 AM TQ 4 PM FOR THE Name of owner of premises FOLLOWING INSPECTIONS: eaw' '' .a-E'f�/eEicd.' 1, FOUNDATION-T,ViIO REQUIRED (As on the tax roll or 1A aED CONCRETE 4 If applicant is a corporation, signature of duly authorized officer a, ROUGH•FRAMING,'PLUMBING, STRAPPING, ELECTRICAL CAULKING (Name and title of corporate officer) 3. INSULATION Builders License No. FINAL•CONSTRUCTION &ELECTRICAL BUST FP COMPLETE FOR C G Plumbers License No. At I r rb r4,UC j ION 1Hf3Ll ArE THE R Electricians License No. f., '' �nE-Ivr OF THE CG ESO NEW J � �' '"CMt IT;,i e W Other Trade's License No. L• T L L,t�,IGN OR CON$TRUCTiON ERRORS, Other 1. Location of land on which proposed wore i e i"iED ., bop , 7g - 4/c�!`.0C G ' ' House Number Street PTamlet County Tax Map No. 1000 Section • /•%, Block -3 Lot- /S Subdivision Filed Map No. Lot 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy b. Intended use and occupancy 3. Nature of work (check which applicable): New Building Addition Alteration Repair Removal Demolition Other Work (Description) 4. Estimated Cost Fee (To be paid on filing this application) 5. If dwelling, number of dwelling units Number of dwelling units on each floor If garage, number of cars 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of existing structures,if any: Front Rear Depth Height Number of Stories Dimensions of same structure with alterations or additions: Front Rear Depth Height Number of Stories 8. Dimensions of entire new construction: Front Rear #De pth Height Number of Stories 9. Size of lot: Front Rear Depth 10. Date of Purchase Name of Former Owner - 11. Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law, ordinance or regulation? YES NO 13. Will lot be re-graded? YES NO Will excess fill be removed from premises? YES NO 14. Names of Owner of premises Address Phone No. Name of Architect Address Phone No Name of Contractor Address Phone No. 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO * IF YES, SOUTHOLD TOWN TRUSTEES & D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey,to scale,with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. 18. Are there any covenants and restrictions with respect to this property? * YES NO * IF YES,PROVIDE A COPY. STATE OF NEW YORK) SS: COUNTY OF ) being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract) above named, NNIE D. BUNCH Nota;Csipii0foui blic,State of New York (S)He is the No.011316165050 G ed iarSuffolK County(Contractor, Agent, Corporate Officer, etc.) t �ra�rnxp6res peri! 14,2G1(o of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be performed in the manner set forth in the application filed therewith. Sworn to efore me thi_ JJ 'day of 1 20 P - 'QJW� I Notary Public re of Applicant a 3-15-13 ,,,,,o$ so�ryol -� p607,:t Town Hall Annex � � • f Telephone(631)765-1802 54375 Main Road � ��,,��++��vvcc gg Qp22 P.O.Box 1176 Q ttt1, roger.rlchG'rt(CULown soutllold.nv.us Southold,NY 11971-0959 ire A •� BUILDING DEPARTMENT TOWN OF SOUTHOLD APPLICATION FOR ELECTRICAL INSPECTION REQUESTED BY: Date: W73 Company Name: 4-,vs ��A`6 • Name: /6f/c/ cJ04-Coe3-5 License No.: ie /4f Address: 7. - Phone No.: JOBS1TE INFORMATION: (*Indicates required information) *Name: oa.&-X cgo ,*2021 *Address: 3a — --� y e - *Cross Street: *Phone No.: 03/— Permit No.: gaS Tax.Map District: 1000 Section: //0 Block: 3 Lot: J`S *BRIEF DESCRIPTION OF WORK(Please Print Clearly) ^' � ay--; ._. //v s%rel/ /a /�/S uJ (Please Circle All That Apply) *Is job ready for inspection: YE et Rough In Final *Do you need a Temp Certificate: YES Temp Information(If.needed) *Service Size: 1 Phase 3Phase 100 150 200 300 350 400 Other *New Service: Re-connect Underground Number of Meters Change of Service Overhead Additional Information: PAYMENT DUE WITH APPLICATION 82-Request for Inspection Form 1 - _ .. _ _. _ ________ ____________________ _ • _. _____ .....,. ......_____.____ __________ ._ .._._______ t , i * . i , . . • 0 . • +St 11V Li*. 7 ; in a ; ..s; -., ; - › - 0 a 0 I i -7 CI 0 < — _ zirl . --,- .... 7 - / 14,1 1 c‘f i W (NI — L-I 1 s "4*fu•C:i" / 7 1 6 ri Tr --I I 1 /I VI T. Li -t 0 0 , ..., ,,- - ‹..,' c) , 0"4 '— -..!. 4 il ... c.LI1, -to ...-- ••,,, ‘• it) i`c - H , „,.. , - p-r... (!J'I ' • JI *4.M , - c 1 1 _ ______ — - 1 .)..._ Ci/fCcd,k CGICeoiii-y inrX frig-P Plinkir” is 4 1 r ... . S.5,*42.7.00"W. -` " la,0'..0 ., - - i ,. , i . ,_.. 4 Lp 5 t 9 pr i I 0,—3—/5-' . „ , . . i -. .icer' F.21 LOT NI t...terorce,s. S--4 ow ik4 ReF fiz fR '''T-0 °- tviAjz, , .. I Or E,er,. -r,94,-Ocpc.-; Es-re---,-re.5" FILED it.4 Ti-TE. , VAP 0 F.:' PP.OP-eMi.j Ne--'' -T : ; 4 - -., Stir"r 0 1.-it Ce.7f...n,..rr r^ CLE-..,rebe`-.5 Orrice_ As. 1 -,-- ,,.1.: . r„,.4„„ i -_cro A 14,-, .. , MAP .,kl oviela Elk-3et8 5ó -n RJR,, t .' rl ILI . ' • -.-. . ,! -- •, _ -`SvAttot:-Nrro„ac:,-ro -re-4 E. /-4,C) .4 TITLE. Diy(SiQNS.-(k--Atc -. `.0;;:-, ? Li u 17C H 0 ql-f.i: - "- ' 2 - T I T L. 1 ts.1 SOir?„60.4-Ct: cc., Aini£.5 ME„. 50ti,"r"*4c,v4.,,,ent SA v 5.$.4-Cu 5 - , '17c4 o0-15 ou-s-Hot-ri:14.Y. . . SAN K , • 'AiT$:;' 161.tRseEyCLi CCT. I , ;.`.. ,;‘,.4t, i . . . , • 1\-40P4UMEit.JT r.r.SEE, LANC., tit.ip.r,E.-y,Or , 1 Gsze.cr.„,..;-..-volac-r. New,'Ycitzw... KOHLER CO,Kohler,Wisconsin 53044 USA Kohler Power Systems R ESA Phone 920-457-4441,Fax 920-459-1646 Asia Pacific Headquarters Models: For the nearest sales and service outlet in the 7 Jurong Pier Road US and Canada,phone 1 800 544-2444 Singapore 619159 MultKOHLER®POWER LPG/Natural-Fuel) Gas KohlerPower corn Phone(65)6264-6422,Fax(65)6264-6455 l Additional RDC2 Controller Features Available Options, Continued • Diagnostic messages Electrical System ®9®0 1 rsrgeern9s.gice ulaet Standard Features o Displays diagnostic messages for the engine,generator, ❑ Battery Model RXT transfer switch, programmable interface _ �� � t "V-..,:•2=4%./ • RDC2 Controller module(PIM), and load control module (LCM) ❑ Battery heater q o Over 70 diagnostic messages can be displayed NATIONALLY REGISTERED FRODLTD'f5W10 o One digital controller manages both the generator set Fuel System and transfer switch functions (with optional Model RXT • Maintenance reminders ❑ Braided stainless steel flexible fuel line r.,_ - r - transfer switch). • System settings 4 . :' ,'~ -`--- o Designed for today's most sophisticated electronics o System voltage;frequency, and phase Literature ° ., -• s,, r - _ o Electronic speed control responds quicklyto varying ��,Fz;� .�,a�_�_�--,-;�,r11.:� '��:a,�^.tip P P rY 9 o Voltage adjustment ❑ General maintenance literature kit _ - . ; ; household demand. o Measurement system, English or metric " ❑ Overhaul literature kit 4.,� o Digital voltage regulation protects your sensitive • ATS status (Model RXT ATS required) " ,, ==, <_` electronics from harmonic distortion and unstable power ❑ Production literature kit T- °`wz o Source availability s 3 '^ , ` ' « ,-;44 quality. o ATS position (normal/utilityor emergency/generator) Starting Aids i E o Two-line, backlit LCD display with adjustable contrast is = ., s=� ° o Source voltage and frequency ❑ Carburetor heater, 120 VAC (recommended for r-;,R; °" ,�c-;�:'',::">--t:,-----,-;---- `Po easy to read, even in direct sunlight or low light. • ATS control (Model RXT ATS required) reliable starting at temperatures below 0°C[32°F]) ° " - • Kohler Command PRO Engine Features o Source voltage and frequency settings ❑ Fuel regulator heater pad (20RESA; recommended for o Kohler Command PRO®OHV engine with hydraulic o Engine start time delay reliable starting at temperatures below-18°C[0°F]) The Kohler® Advantage valve lifters for reliable performance without routine o Transfer time delays valve adjustment or lengthy break-in requirements o Voltage calibration Kohler®Automatic Transfer Switch • High Quality Power o, Powerful, reliable air-cooled performance Kohler home generators provide advanced voltage and o Simple field conversion between natural gas and LPG o Fixed pickupand dropout settings ❑ Model RXT,see specification sheet G11-121 P P 9 frequency regulation along with ultra-low levels of fuels while maintaining emission certification • Programmable Interface Module(PIM)status displays ❑ Model RDT,see specification sheet G11-98 harmonic distortion for excellent generator power quality to o Input status (activefinactive) ❑ Model RSB,see specification sheet G11-101 - protect your valuable electronics. • Designed for Easy Installation o Output status (active/inactive) o • Extraordinary Reliability o Polymer base eliminates the need for a concrete P CI Other Kohler ATS • Load control module (LCM) menus Kohler is known for extraordinary reliability and mounting pad, reducing installation time and cost o Load status Miscellaneous Accessories performance and backs that up with an industry-leading o Hinged, locking roof o Test function Li ' 5-year or 2000 hour warranty. o Fuel and electrical connections through the enclosure • Powerful Performance wall eliminate the need for stub-ups through the bottom Generator Set Standard Features Li Exclusive Powerboost° technology provides excellent o Load connection terminal block allows easy field wiring • Battery cables starting power. The Kohler 14 kW generator can easily o Designed for outdoor installation only • CARB (14RESA only) and EPA certified fuel system start and run a 5 ton air conditioner.* • Certifications • Corrosion-proof polymer sound enclosure • Corrosion-Proof Enclosure o Meets emission regulations for CA 2011 and later LSI • Critical silencer Generator Set Dimensions and Weights The bold new Kohler design is completely corrosion proof, engines (14RESA only)and U.S. Environmental Overall Size,L x W x H: 1216 x 665 x 733 mm even in harsh seaside environments, and is Protection Agency(EPA) phase 2 small off-road engines • Field connection terminal block (48 x 26 2 x 29 in.) impact-resistant even at-34° C(-30° F). with both LPG and natural gas • Fuel solenoid valve and secondary regulator Shipping Weight: 14RESA 191 kg(420 lb.) • Fast Response o UL 2200 listed (60 Hz model) • Line circuit breaker: 20RESA 243 kg (535 lb.) F. ` ' Kohler's unique Fast-Response° excitation system o CSA certification available (60 Hz model) 14RESA: 70 amps - delivers excellent voltage response and short-circuit o Approved for stationary standby applications in locations 20RESA: 100 amps L capability. served by a reliable utility source • Multi-fuel system, LPG/natural gas,field convertible �_�_-- ��- • Quiet Operation o Model 14RESA is also approved for non-standby • Oil drain extension with shutoff valve -----....'- - Kohler home generators provide quiet, neighborhood- (off-grid) applications (18 month or 1000 hour warranty • Premium 5-year limited warranty H friendly performance. applies for non-standby applications) • 18-month limited warranty for non-standby(off-grid) applications (14RESA only) ' • RDC2 generator set/ATS controller IS'S�I— ,�,�� -I Generator Ratings W • Rodent-resistant construction Standby Ratings NOTE Dimensions are provided for reference only and should not be used for planning • Sound-deadening,flame-retardant foam per UL 94, installation Contact your local distnbutor for more detailed information. Natural Gas LPG class HF-1 Model Voltage Phase Hz Alternator kW/kVA Amps kW/kVA Amps DISTRIBUTED BY: Available Options 14RESA 120/240 1 60 2F5 12/12 50.0 14/14 58.3 p 115/230 ' 1 50 2F5 10/10 43.5 11/11 47.8 Communication Accessories 120/240 1 60 2F7 18/18 75 0 20/20 83 3 ❑ OnCue®Generator Management System 20RESA 115/230 1 50 2F7 14/14 60.8 15/15 65.2 Controller Accessories ( RATINGS Standby ratings apply to installations served byareliable utility sour Plsingle-phase units arerated at1.0power factor The standby rating is applicable to variable loads with an average load factor of 80%for the duration of the power outage No overload capacity is specified at this rating Ratings s are in accordance M4 150-3046/1,BS5514,AS2789,and DIN 6271 GENERAL ❑ Programmable Interface Module (PIM) GUIDELINES FOR DERATING ALTITUDE:Derate 4%per 305 m(1000 ft)elevation above 153 m(500 ft) TEMPERATURE Derate 2%per 5.5°C(10°F)temperature increase above 16°C(60°F) Availability is sublect to change without notice The generator set manufacturer reserves the nght to change the design or specifications without notice and without any obligation or liability whatsoever (provides 2 digital inputs and 6 relay outputs) Contact your local Kohler Co.generator distributor for availability ❑ Load Control Module (LCM) * Check the appliance manufacturer's specifications for actual power requirements Consult a Kohler®Power Systems professional to calculate your exact residential power system requirements. (provides 4 power relays and 2 HVAC relays) ©2011,2012 by Kohler Co All rights reserved 04-209 (14/20RESA) 8/12bG4-209 (14/20RESA) 8/12b Alternator Specifications Fuel Requirements Alternator Specifications Alternator Features RDC2 Controller Fuel System 14RESA 20RESA PowerBoost'" Generator Fuel types Specifications 1-Phase • Compliance with NEMA, IEEE, and ANSI standards for Natural Gas or LPG 116"ElLasiEms ltemperature riseFuel supply inlet 1/2 NPTJI/Manufacturer Kohler (VoRage zaov O 120/240 • Self ventilated and dripproof construction f Fuel supply pressure,kPa(in H2O) IF�� 600Hzl Output reconnectable 1 �1 ®� Natural gas 1.2-2.7(5-11) co 1 Type 2-Pole, Rotating Field • Vacuum impregnated windings with fungus resistant O°0 LP 1 7-2.7(7 11) - ®)((®)���� Leads,quantity 4 epoxy varnish for dependability and long life _ Fuel Composition Limits* Nat.Gas LPG O Voltage regulator Digital • Superior voltage waveform and minimum harmonic % �f__"_?� -0 0 0 o_a Insulation Methane, by volume(minimum) 90 min. NEMA MG1-1 66 distortion from skewed alternator construction Ethane,%by volume(maximum) 4.0 max. ±1.0% no-load to full-load Propane,%byvolume The RDC2 controller provides integrated control for the Material Class H • Digital voltage regulator with Temperature rise RMS re P 1.0 max. 85 min. Class H regulation Propene,%by volume(maximum) 01 max. 5.0 max generator set, Kohler®Model RXT transfer switch, Bearing.quantity,type 1,Sealed Ball • Rotating-field alternator with static exciter for excellent C4and higher,%byvolume programmable interface module (PIM), and load control module 9 0 3 max 2.5 max programmable Coupling Direct load response Sulfur,ppm mass(maximum) 25 max. (LCM). Amortisseur windings Full Lower heatinvalue, The RDC2 controller's 2-line LCD screen displays status Voltage regulation,no-load to full-load MJ/m3(Btu/ft3),min. 33.2(890) 84.2(2260) messages and system settings that are clear and easy to read, * Contact your local distributor for suitability and rating derates based even in direct sunlight or low light. RMS ±1.0% One-step load acceptance 100%of Rating on fuel compositions outside these limits. Peak motor starting kVA @ 240 V RDC2 Controller Features 14RESA ®peratlOn Requirements35 • Membrane keypad 20RESA 40.5 C Fuel Consumption o OFF,AUTO,and RUN pushbuttons Fuel Fuel Consumption,m3/hr.(cfh) o Select and arrow buttons for access to system Model Type %Load 60 Hz 50 Hz configuration and adjustment menus Application Data 100 5.4 (193) 4.9 (175) • LED indicators for OFF,AUTO, and RUN modes Engine Engine Electrical 75 4 7 (163) 4.2 (148) • LED indicators for utility power and generator set source Engine Specifications Natural availability and ATS position (Model RXT transfer switch 14RESA 20RESA Engine Electrical System 14RESA 20RESA Gas 50 3 5 (124) 3 1 (108) required) Manufacturer Kohler Ignition system 25 2 6 (93) 2 4 Electronic, (84) • LCD display Engine model,type CH740 CH1000 Capacitive Discharge Exercise 1.7 (60) 1.7 Cy 14RESA (60) o Two lines x 16 characters per line 4-Cycle 4-Cycle Starter motor rated voltage(DC) 12 / 100 2.3 (81) 2.1 (74) o Backlit display with adjustable contrast for excellent Cylinder arrangement V-2 Battery(purchased separately): ( 75 21 (75) 1 9 (68) visibility in all lighting conditions Displacement,cm3(cu.in.) 725(44) 999(61) Ground Negative - LPG 50 1.8 Bore and stroke,mm(in.) 83 x 67 90 x 78.5 Volts(DC) (60) 1.5 (53) • Scrolling system status display 12 25 1 2 (45) - 1.1 (40) o Generator set status (3.27 x 2.64) (3.54 x 3.1) Battery quantity ` 1 o Voltage and frequency Compression ratio 9:1 8 8:1 Exercise 0 8 (30) 0 8 (30) Main Compression bearings-quantity,type Recommended cold cranking amps' 100 8.0 (281) 6.4 (225) o Engine temperature 2,Parent Material (CCA) rating for-18°C(0°F) 500 o Oil pressure Rated RPM 60 Hz 3600 Group size 51 Natural 75 6.9 (243) 5.4 (189) o Battery voltage 50 Hz Gas 50 4.6 (161) 3.9 (139) o Engine runtime hours 3000 Lubrication 25 3.6 (127) 29 (103 g • Date and time displays Max.engine power at rated rpm,kW(HP) Lubricating System 14RESA 20RESA Exercise 2.0 (71) 2 0 (71) LPG,60 Hz 20RESA Smart engine cooldown senses engine temperature 17.6(23 6) 23.0(30.9) Type Full Pressure - 100 3 9 (136) 2.9 (102) • Digital isochronous governor to maintain steady-state speed LPG,50 Hz 15.8(21 2) 20.0(26.8) Oil capacity(with filter),L(qt) 1.9(2.0) 2.8(3.0) 75 3.1 (109) 2.4 Naturalgas,60 Hz (85) at all loads 15.3(20.5) 20.2(27.1) Oil filter:quantity,type 1,Cartridge LPG 50 2 3 (82) 1.8 (63) • Digital voltage regulation: ±1.0% RMS no-load to full-load Natural gas,50 Hz 13 8 (18.5) 16.8(22.5) Oil cooler Cylinder head material Integral 25 1.7 (59) 1.3 (47) • Automatic start with programmed cranking cycle Aluminum Fuel Pipe Size Exercise 1.0 (35) 1.0 35 Valve material Stelumin Mite® ( ) • Programmable exerciser can be set to start automatically on Nominal fuel rating: Natural gas: 37 MJ/m3(1000 Btu/ft.3) any future day and time, and run every week or every two Piston type and material Aluminum Alloy Minimum Gas Pipe Size Recommendation,in.NPT LPG. 93 MJ/m3(2500 Btu/ft.3) weeks Crankshaft material Heat Treated,Ductile Iron 14RESA 20RESA LPG conversion factors: 8 58 ft.3=1 lb Governor:type • Exercise modes Electronic Natural Natural 0.535 m3=1 kg Frequency regulation,no load to full load Isochronous Pipe Gas LPG Gas LPG 36 39 ft.3 =1 gal. a Unloaded weekly exercise with complete system Frequency regulation,steady state ,0 on Length, 193,000 203,000 281,000 340,000 diagnostics m(ft.) Btu/hr. Btu/hr. Btu/hr. Btu/hr. o Unloaded full speed exercise Air cleaner type pry Sound Data 8 (25) 3/4 1 3/4 o Loaded full speed exercise (Model RXT ATS required) Exhaust 15 (50) 1 3/4/q 1 1 Model 14RESA sourid level is 63 dBA during weekly engine • Front-access mini UB connector for SiteTech"" connection exercise and 67 dBA during full-speed generator diagnostics • Front access mini-breaker protects the alternator Exhaust System 14RESA 20RESA 30 (100) 1 1 1 1/4' 1 and normal operation. Exhaust temperature exiting the 46 (150) 1 1/4 1 1 1/4 1 1/4 • Integral Ethernet connector for Kohler OnCue " 4 Model 20RESA sound level is 64 dBA during weekly engine • Built-in 2.5 amp battery charger enclosure at rated kW,dry, °C(°F) 260(500) 61 (200) 1 1/4 1 1 1/4 1 1 / ( exercise and 69 dBA during full speed generator diagnostics • Remote two-wire start/stop capability for optional connection and normal operation. of Model RDT or RSB transfer switches All sound levels are measured at 7 meters with no load. See additional controller features on the next page. G4-209 (14/20RESA) 8/12b G4-209 (14/20RESA) 8/12b