Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
40203-Z
,,.S� o� TOWN OF SOUTHOLD �o� e�� ,; BUILDING DEPARTMENT TOWN CLERK'S OFFICE f •oy 0:47 SOUTHOLD, NY dol * -0„4 BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 40203 Date: 10/22/2015 Permission is hereby granted to: • Beebe, Constance 24925 Route 25 PO BOX 979 Cutchogue, NY 11935 • To: Install roof-mounted solar panels on existing accessory building as applied for. \1DLi NDI— gUtk:r At premises located at: 24925 Route 25, Cutchogue SCTM #473889 • Sec/Block/Lot# 109.-120.3 Pursuant to application dated 10/14/2015 and approved by the Building Inspector. To expire on 4/22/2017. Fees: SOLAR PANELS $50.00 CO -ALTERATION TO DWELLING $50.00 ELECTRIC $100.00 Total: $200.00 AI . Building Inspector I _ Farm No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: I. Final survey of property with accurate location of all buildings,property lines,streets,and unusual natural or topographic features. 2. Final Approval from Health Dept.of water supply and sewerage-disposal (S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1%lead. 5. Commercial building, industrial building,multiple residences and similar buildings and installations,a certificate - of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings(prior to April 9, 1957)non-conforming uses,or buildings and"pre-existing"land uses: I. Accurate survey of property showing all property lines,streets,building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. !fa Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00,Alterations to dwelling$50.00. Swimming pool$50.00.Accessory building$50.00.Additions to accessory building$50.00. Businesses$50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy-$.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy- Residential $15.00,Commercial$15.00 Date. .•- _•-_2Q //p� New Construction: __ _ _,Old or Pre-existing Building: �� (check one) Location of Property: a-y-L gr /Nitv , as- _ k/c4.!5(.....R___ A/ ._ /a 7 3'J House No. S ret et Hamlet Owner or Owners of Property: __. S+Ctrl Q � (i - - Suffolk County Tax Map No 1000.Section__ 1 pc. _ _ Block_____ 1_ __ Lot a� Subdivision �___ __ _ Filed Map. _ _l Lot: Permit No. _-1-(a3 ___ Date of Permit. Applicant:___S 6 1al- Cl _ f lealth Dept. Approval: Underwriters Approval: Planning Board Approval: _ _ ---------- Request _____^—Request for: Temporary Certificate ___ final Certificate:__ __ _ (check one) Fee Submitted: $ BSO. c-O Applicant Signature 9 (/L k LH LD 'SP.E QN IZE1''OIer . DATE ,.�... COWRY:TS � � i----- --•• ••b ' FOUNDATION(1ST) o cj wino..p• 1. A , • FOUNDATION(2ND) . , _. . . • . C4 ...............= . ROUGH�G& ii PLUMBING N .—•,,r- .. • ck t:4 INSULATION'FERN,Y. —"••""*' ', . STATE ENERGY CODE - - • ' . • . ., , • -N o-r- . FINAL • ai ADIS1not L: (.-ommc. ' — (-° 0../L iii;' mow", -( ,_ _ s� S3 G .:m.6) , -,. pro • • PZI 13 r\ �: . . ..C2 . . . . , . ._,. , . . , . . . N . . . . , . ' z � . • 1, v , l .• SolarCit = � ©LGVY n L D MAR 282016 March 24, 2016 Tom° D��T• mallow Town of Southold Attn: Building Department Town Hall Annex 54375 Route 25 Southold, NY 11791 NOTICE OF CANCELLATION This letter is to certify our permit to install Solar (PV) at the property listed below has moved into a cancellation status. Constance Beebe 24925 Rt. 25 Cutchogue, NY 11935 Permit #: 40203 SolarCity Corporation and Constance Beebe will not be moving forward with the installation of solar panels at the above location. If you have any questions/concerns, please contact myself directly. Sincerely, pav'(. LOS ctu.adro Pam Losquadro, Inspection Coordinator plosquadro@a.solarcitv.com (631) 636-4367 923C Motor Pkwy.,Hauppauge,NY 11788 T (888)SOL-CITY solarclty.com AL 05500.AR M-8937.AZ ROC 24377VR0C 245450,CA CSLB 888104,CO EC8041.C1 HIC 0632778/ELC 0125305,DC 410514000080/ECC902585,DE 2011120386/T1-6032.FL ECI3006226,HI CT-29770.IL 15-0052.MA HIC 168572/ EL-1136MR.MD HIC 12894B/11805.NC 30801-0.NH 0347C/12523M.NJ NJH1C#13V1-i06160600/34E801732700.NM EE98-379590.NV NV20121135172/C2-0078648/B2-0079719.OH EL 47707.OR arta 0498/C562,PA H1CPA077343,RI AC004714/Reg 38313 TXTECL27006,UT 8726950-5501.VA ELE2705153218.VT EM-05829.WA SOLARC•9190VSOLARC•905P7,Albany 439.Greene A-486.Nassau H2409710030.Putnam PC6041.Rockland H-11864-40-00-00.Suffolk 52057-H,Westchester WC-26088-H13.N Y C#2001384-DCA.SCENYC NYC Licensed Electrician.#12610#004405,155 Water St 6th Fl.Unit W.Brooklyn.NY 11201#2013966-DCA All loans provided by SolarCity Finance Company.LLC CA Finance Lenders License 6054796 SolarCity Finance Company.LLC is licensed by the Delaware State Bank Commissioner to engage in business in Delaware under license number 019422.1,4D Consumer Loan License 224t NV Installment Loan License 11.8023/111024.Rhode Island Licensed Lender#20153103LL,TX Red stered Creditor 1400050963-202404,VT Lender License#6766 „uiL„11l.., ,,,,r 1,n i ivi�>�>< Do you have or need the following,befoib-,applying? TOWN HALL Board of Health �` � 'SOUTHOLD;NY 11971 4 sets of Building Plans ,, TEL: (631) 765-1802 k Planning Board approval �., FAX: (631) 765-9502 Survey SoutholdTown.NorthFork.net PERMIT NO. ' o3 2 Check Septic Form N.Y.S.D.E.C. Trustees C.O. Application Flood Permit Examined 0-, ,20 /5 Single&Separate Storm-Water Assessment Form Contact: lb Approved Ps;20 Mail to: 54u�4- C Disapproved a/c G'l 3 M1-cr Pic vll,S,,ei{• c 14=1P1'” 2- 1"'s, • /I19-11-r Expiration - _ �'�"L� -� (03/ - 3s- ,P-7- jiil L� iii L !' \ H IL.--) I _ ij Building Inspector I OCT 142015 , PPLICATION FOR BUILDING PERMIT Date /OA , 20 /-J.-. INSTRUCTIONS a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans, accurate plot plan to scale. Fee according to schedule. b. Plot plan showing location of lot and of buildings on premises, relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit ;hall be kept on the premises available for inspection throughout the work. e. No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector ssues a Certificate of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of ssuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the rroperty have been enacted in the interim, the Building Inspector may authorize, in writing,the extension of the permit for an ddition six months.Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE-to'-the Bi ilding-Department for the issuance of a Building Permit pursuant to the Wilding Zone Ordinance of the Town of Southold, Suffolk County,New York;and other applicable Laws, Ordinances or egulations,for the construction of buildings,additions,or alterations or for removal or demolition as herein described. The pplicant agrees to comply with all applicable laws,ordinances, building code, housing code, and regulations,and to admit uthorized inspectors on premises and in building for necessary inspections. - .„,_ .-4 . g attire of applicant or name, i' corporation) ro3 /b% Pkevy C /4t- (Mailing addiess of applicant) tib' //90- .ate whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder 0.0Aa min-4).ed- ame of owner of premises ( #?J -a,i C.C. eel...ht., (As on the tax roll or latest deed) applicant is a corporation, signature of duly authorized officer (Name and title of corporate officer) !ilders License No. 5.20 SI- /4 .rmbers License No. cctricinns License No; $' /3 3 / MP her Trade's License No. Location of land on which pro osed work will e done: a V 1 a r A-t t4 Rd.__ .-0r,.will - /�/ . P 93,,Sr House Number Street , �'>` Hamlet . .,, , County Tax Map No. 1000 Section :• ,1 Ca-. .r.,,:Block / Lot Subdivision Filed Map No. Lot 2. State existing use and occupancy of premises anintended use and occupancy of proposed construction: a. Existing use and occupancy /-CS/ atvidieJ b. Intended use and occupancy 3. Nature of work (check which applicable): New Building Addition Alteration Repair . Removal Demolition Other Work )rwf flc. of 4. Estimated Cost 6 If 163 Fee (Description) (To be paid on filing this application) 5. If dwelling,-number of dwelling units Number of dwelling units on each floor If garage, number of cars 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of existing structures, if any: Front Rear 'Depth Height Number of Stories Dimensions of same'structure with alterations or additions: Front Rear Depth Height Number of Stories 8. Dimensions of entire new construction: Front Rear Depth Height Number of Stories 9. Size of lot: Front Rear Depth 10. Date of Purchase Name of Former Owner 11. Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law, ordinance or regulation? YES NO 13. Will lot be re-graded? YES NO Will excess fill be removed from premises? YES NO .? V 9.D 6-/gain 14. Names of Owner ofpremises Cv^J/ane� ��AddresA'M vt/4' `I' Phone No.63/" �t -1 Name of Architect AGI G I N� A .j-f-vas r Address 3(Tr 6(eccrpe, G.•' hone No 6 Sd- 3r-/0 a f Name of Contractor co/(p r £ Address 9a3 /109-P tol Phone No. 4 3/- Y®( 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO * IF YES, SOUTHOLD TOWN TRUSTEES & D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO lit"'"- *, S* IF YES, D.E.C. PERMITS MAY BE REQUIRED. • 16. Provide survey, to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. 18. Are there any covenants and restrictions with respect to this property? * YES NO * IF YES, PROVIDE A COPY. STATE OF NEW YORK) SS: COUNTY OF ) �-cam 1�� - being duly sworn, deposes and says that(s)he is the applicant ..�/ (Name of individual signing cont act)above n med, (S)He is the a,' Cankci.e_A-c-r- (Contr ctor, Agent, Corporate Ofcer,etc.) of said owner or owners,and is duly authorized to perform or hav-., - • •• •-! .. - '• . .•. .nd to make and file this application; that all statements contained in this application are true to he best otilifAl 1P +,_e d beli-f;and that the work will be performed in the manner set forth in the application filed t.i 15eg BLon'No.O1PE632E4an70 Qualified in Suffolk Cour, �� Sworn to before me this Commission Expires August3,10 _ l h day of cor1ilicr ( 20 15 y. j.e.Th -7.cf,„(,, _ • .. cianntnre of Anolicant • Scoff A. Russell te yi - ��r SUP VISOR g MANAGEMENT N AGEM SOUTOL D TOWN HALL..r o-Box y I3 yyy]y =3- c '-`t�-y�7'� D r 07�t �20� YORK F9n ~ 53095 Main Rost!-SI�Z13gO�.A.N� + '•,• •.,� Qu. ., sew r+---�.,„.,.je}fit' CHAPTER 236 - sTORMVVATER.MNAGEENT.W9RX SHEET (TO BE COMPLETED BY THE APPLICANT) • i-.�..._n...- .__..—•DOES p.aiS PKOJ C rivo �l .�1N3L • OF • H �COILOYr1N9 - ._........—_; (cliEO Ata.'MAT APPLY) Yes No 0 ;A A. Clearing, grubbing, grading or.stripping of land which affects more than 5,000 square feet of ground surface_ 0 EPB. Excavation or filling involving more than 200 cubic yards.of material within any parcel or any contiguous area. 0 . Site preparation on slopes which exceed 10 feet vertical rise to . 100 feet of horizontal distance. - . In. Site preparation within 100 feet of wetlands, beach, bluff or coastal erosion hazard area. faE. Site preparation within the one-hundred--)'ear floodplain as depicted • on p'xR1VI Map of any watercourse. 0E44'. installation of new or resurfaced impervious surfaces of 1,000 square . feet or more, unless prior approval of a Stormwater Management Control Plan was received by the Town and the proposal includes • in-kind replacement of impervious surfaces. * If you answered NO to all of the questions above,STOri Complete the Applicant section below with your Name, Signature,Contact Information,Date &County To Map Number'!. Chapter 236 does not apply to your project. If you answered 1 S to one or more of the above,please submit The copies of a Stormwater Management Control P lan and a completed Check List Form to the Building'Department wit am Building Permit Application. APPWANT:to eny owner:&son Ptatkssianat,Agent,Contractor.Other) 1 S'CT. s MOO trnta CiA, gam �ir 1 -S�I4I Ctkl : ) ©°l T �r� � .• .. Section Block La ... �PC' / "'� d9,93-- 91-00 ' ' FOR BUILD 10 DEPART iEN`I'USE ONLY' Contact Infexmnsom r 3/ • Reviewed By. i'VLP ,N 1 Date I011t 1!c Property Address/L.ocation of Consti action Work: 2 7 g c2 3 /v AI �C�4- Approved for processing Building Permit. � Stormwatcr Management Control Plan Not Required_ -e -C ii) 3 �` I— ri Storm water Management Control Pian is Required. (Forward to Engineering Department for Review.) FORM " SMCP-TOS MAY 2014 ' ii • Q LOtiE7. ; QI : 1 I ft7i-Qn-in a0 Town Hall Annex JI • 46 Telephone(631)765-1802 • (631)765- 5q2 54375 o.Box 1 sd Q +� roger.richett(aown.soutF7olld.nv.us Southold,NY 11971-0959 Q '� •�� BUILDING DEPARTMENT TOWN OF SOUTHOLD • APPLICATION FOR ELECTRICAL INSPECTION REQUESTED BY: aJ I'9 CA- Date: 10-1 - (5 Company Name: • Name: • License No.: Address: • Phone No.: JOBSITE INFORMATION: (*Indicates required information) *Name: *Address: 021 I a,�`" /V a-w /14, J l 93S *Cross Street: / O *Phone No..: (p 3 - Lt.-3-1" -t r 3-q PermitNo.: a � Tax-Map District: 1000 Section: \r Block: - Lot: . *BRIEF DESCRIPTIO OF WORK(Please Print Clearly) • . • r,►2 i SA r Pctrv...lS • • O . CIS � � (Please Circle Ali That Apply) !� *ls job ready for inspection: YES/Q.) Rough In Final *D0•you need a Temp Certificate: NO Temp information(If needed) *Service Size: 9 Phase 3Phase 100 150 200 300 350 400 Other *New Service: Re-connect Underground Number of Meters Change of Service Overhead Additional information: PAYMENT DUE WITH APPLICATION 82-Request for Inspection Form '' r Ca./a- 0,1 N f Mt1' Y p��°�5 ib• -� spQ. SURVEY OF PROPERTY E.�a°ti ter. SITUATED AT 4 ° CUTCHOGUE 0 [06 y6'y TOWN OF SOUTHOLD SUFFOLK COUNTY, NEW YORK �— d•T� S.C. TAX No 1000-109-01-20.3 ,qf`,n• _�, ' �aA' \ SCALE 1'•=20• ` OCTOBER 28, 2003 y MARCH 25, 2005 PROPOSED DRIVEWAY RELOCATION MAY 26, 2006 SET PROPERTY CORNERS A1' / WY 23, 2007 ADDED SPOT ELEVATIONS& PROPOSED ADDITION (. . T3o.• AREA = 35,530.41 sq. ft. *- `_',>,'H 0% 0 816 ac. 50. , N. 056 .:0nf NOTES. .2x �"�p''Yo 1 ELEVATIONS ARE REFERENCED TO AN ASSUMED DATUM 4.--ei, EXISTING ELEVATIONS ARE SHOWN THUS•a39 0 4.,t,, '4G G. ese en EXISTING TOTAL LOT COVERAGE DATA _9.r4, <"' DESCRIPTION AREA X LOT,COVERAGE ?' e HOUSE W/PORCHES 2 559 sq It 7 3% ,pq aOQ o ,0. CONE RAMP 176 sq It DOS 0 '$ f S 393 - FRAME SHOP 1,318 sq II 37% /� °` R'' ' ASPHALT DRIVEWAY 1,940 eq II 55% P+ .eB� AO CONS PAVEMENT 1.362 TO II 38% S� N� 'V �r- TOTAL EXISTING I 7 387 so I1 20 8% J (/ C-,_II O7 cf % NO. ` ��, T PROPOSED TOTAL LOT COVERAGE DATA s .e. DESCRIPTION ARCA I%LOT COV[RARC o- e¢ HOUSE W/PORCHES 2,569 eq It 73% CONE RAMP 176 eq It O5% FRAME SHOP 1 1 318 a9 It 37% CO o. ' CONE PAVEMENT 1,362 sq N 38% A 7 y PROP ADDITION 1,500 xq 11 A2% TIC, / OGSf O� PROP DRIVEWAY 2,729 a9 11 77% <0 } u TOTAL PROPOSED 9,676 sq II 27 2% �m� \ /tF Y C91�C�f ,13'61 1.51 Z /a .`) a+ y. �� Jus P / d /(CORPANCC WIT MS WAN. A� 1 • ' 4. Ai •'-'4'. Nl ,\\- o'` SrC Of 114OPoR PPE S E AOUS N 8' [V FOR SUCH.OAPOMD•la NEW rover sreT�E I• I ,E /J \ \\\ \ \ bO1�) • {1`f t ,§ I (4 `41 1\ -� \ oo 5`°,i �'`'' 'R'','I t kN .. D�Vfµ'AY,oNE-w \ 5600 a)A•, ,, CgTO � 5 n ��� ``�1',7 .��f NYS Lc NO 99668 ® \ I N p6 • '' K. ''"O UNWR6gPPID K'OumH OR AOOIrox pR1 61• • 1' Joseph A. Ingegno m s R E ,n RaN o o .@ •,� �'', _ _ de �0 O Ta w of,, xlw Yalx -. 0.11011 LAW Land Surveyor co-.E SURVEYOR'S OHM xa °\ '4') 4 \ l RSM 25'( TTOO'BE A VA1n PPECOPYCOP T B[CONSOrnCD q{�� P .•l 1 • .0..•'./Cy$OM • CRTECATOHS HEREON BwLL Q. \ B00 `1` (`�1' I DNe Surveys-SVbdnalans- Sao Pana- COmlraal/m L i0 M[KR�wl.BHOM TTO SURVEY '(�.1 l r Layout ONLY ARO 19 ws LOLIBAVY T.AGENCYµo s, C)y . • 7 PHONE(631)727-2090 Fax(631)727-1727 O I" m „tr606mO 0000 ®' $6 O ',eV? C�� WON CLmRrAT'O,s mAxLEwaL OFPICES LOCATED AT WONG ADDRESS �`� / ^ `,,P`� 322 ROAIDKE AVOW PO Bo.1931 TIE EKISTCNCE I#MONIS OF WAY RIVERHEAD,Nem Yah 11901 RNerNBRA,Nam Yoh 11901-0985 AND/OR EA6CYE%T$IX gCFARO IF ANY,NOT SHOWN ARE NOT CDARANTCCO (( • 23-4261) SUFFOLK Comm(DEPT OF LABOR, ' IMENSING&CONSUMER AFFASRS t, HOME IMPROVEMENT CONTRACTOR LICENSE , „ ,•--,,, .,;.'J SHAUN E CHAPMAN This cedifies that the cume°44m bearer is duly SOLAR CITY CORPORATION &tensed by the • Dilstlaad Ceunty of Suffolk 52057-H 08101/2013 ..- C111.10,01.V alm2"""twa 08101/2017 ' glik'. SUPFOUt COUNTICEPT tILABOR, CENSiNGCONSUMERoF APPARS oyELECTRICIAN , •,°z.r, 'e:!..". ', ' . JASON KANE iagmeommommiii ' Tim ostlfen Mt the mmwmclu bearer is duty SOAR CRY CORR Ebefteed bythe County at Suffolk " ig...,... 51331-ME I olostmon Masame.a. min.c...0.0., 1 =vs'''. 03101/2017 1 • • . • Version#43.1 • o SoIarCity April 7,2015 Project/Job# 119508 RE: CERTIFICATION LETTER Project: Beebe Residence 24925 New York 25 Cutchogue,NY 11935 To Whom It May Concern, A jobsite survey of the existing framing system was performed by a site survey team from SolarCity. Structural review was based on site observations and the design criteria listed below: Design Criteria: -Applicable Codes= 2010 Residential Code of NY State,ASCE 7-05,and 2005 NDS -Risk Category=II -Wind Speed = 120 mph,Exposure Category C -Ground Snow Load = 20 psf -MP1: Roof DL= 10 psf,Roof LL/SL= 18 psf(Non-PV Areas), Roof LL/SL= 16.8 psf(PV Areas) Note: Per IBC 1613.1; Seismic check is not required because Ss =0.20021 < 0.4g and Seismic Design Category(SDC) = B < D On the above referenced project,the components of the structural roof framing impacted by the installation of the PV assembly have been reviewed. After this review it has been determined that the existing structure is adequate to withstand the applicable roof dead load,PV assembly load and live/snow loads indicated in the design criteria above. I certify that the structural roof framing and the new attachments that directly support the gravity loading and wind uplift loading from PV modules have been reviewed and determined to meet or exceed structural strength requirements of the 2010 Residential Code of NY State. " OFNE14i_N Please contact me with any questions or concerns regarding this project. (Aito P►' H!/, O * Sincerely, ,, A•. rt Elaine A. Huang,P.E. ft 4±+11 WJ Professional Engineer Z41$Q dZ/ Direct: 978.406.8921 t� email: elaine@eahstructural.com AR 064S 01'N#-/3055 Clearvil w Way San Mateo,CA 94402 T(650)638-1028 (888)SOL-CI eQFESSI�//�(q/ A7_ROC 24;e7!7,CA C SLE 888104 CO 60 80.71,CT HIC 0632778,DC 410 71901788 1)0 HIS 1101488 HI GT 28770,1 e IF CR CC3 160496 PA 0i 7343 TX-MLR 27006,1NA CCL SO ARC'91007 12 2013 Solar 04.07.2015 ,eek. Version#43.1 7;:rA k 5 olie 4.x3Crty, PV System St[ruc tore PROJECT INFORMATION &TABLE OF CONTENTS __ ,"__Project Name:._ __..,..._ ._Beebe Residence_ , , ,.�____,,,� AHJ: _ . „_•__ ,Southold Town .v _m_`_ ___ Job Number: _ 119508 _ Building Code: 2010 Residential Code of NY State . 7_ _ — Customer Name:_ f Beebe, onstence R_ _______ Based On_____:_IRC 2006/fat 2006 ____w__ _ Address: _ _ 24925_ New York 25 ASCE Code: _ ASCE 7-05 _ _- _�_ _� City/State: _d�._ Cutchogue,_�.�.�. ._NY -------- RiskCategoy:_ :w__. . _ • II...a. _� .,. ...._.._ _ - _ Zip Code 11935 Upgrades Req'd? No __-_�, Latitudey/Longitude:,__.__4i.-04766____ 72.494400-•_y,�.._ Stamp,Reg'd?, Yes yw _ SC Office: Long Island PV Designer: Sangita Sharma Calculations: - Ryan Atwell EOR: Elaine A. Huang,P.E. Certification Letter 1 Project Information, Table Of Contents, &Vicinity Map 2 Structure Analysis (Loading Summary and Member Check) 3 Hardware Design (PV System Assembly) 4 Note: Per IBC 1613.1; Seismic check is not required because Ss=0.20021 < 0.4g and Seismic Design Category(SDC) = B < D 1 2-MILE VICINITY MAP .,` ;\ ,,.. d'e 1:4-.- , .4, . . 4 k.fr..'"7,;. 1 •• 1. _, . y' 1 N 14.4 `4 tr a/ ' — ,, 't St , c i # IIS y .' ' i 1 `+i... 0. "A. 4,,i ,fit ca . g '8S; u a.a c2�.. . oo•Ie sl,rr1e@e. 02015 , Di .ewlo k-GI , US /.. af.1.1Servi"ceA•e.n..0 24925 New York 25, Cutchogue, NY 11935 Latitude:41.004766,Longitude: -72.4944,Exposure Category:C tSTRUCTURE ANALYSIS_-_LOADING SUMMARY AND MEMBER CHECK- 0i - = . - -.11 Member Properties Summary , _ MPI; Horizontal Member Spans , Rafter Properties „ Overhang 1.16 ft Actual W 1.50" Roof System Properties Span 1 12.75 ft , ' Actual'D 5.50" . Number of Spans(w/o Overhang) 1 Span 2 - Nominal Yes Roofing Material ` , - ` Comp Roof' Span 3'" ., - A" ' • ` 8.25 in.^2 . Re-Roof No Span 4 SX 7.56 in.^3 Plywood Sheathing - - ' `Yes Span 5 " Li . ' , ,20.80^in.^4` Board Sheathing _ None Total Span 13.91 ft TL Defl'n Limit 120 Vaulted Ceiling, . - -W , No ,: . PV 1 Start - .4.42 ft , , Wood Species SPF - Ceiling Finish 1/2"Gypsum Board PV 1 End 14.42 ft Wood Grade #2 Rafter Slope -, - 26° - PV 2 Start - _" Fb , - , 875 psi Rafter Spacing 16"O.C. PV 2 End F„ 135 psi - Top Lat Bracing ` - Full PV 3 Start ' ' E -1400000.Psi Bot Lat Bracing At Supports PV 3 End Emin 510000 psi ' ` ` - Member Loading Summary ` Roof Pitch' `6/12 ` Initial ' Pitch Adjust Non-PV Areas ' ` PV Areas Roof Dead Load DL 10.0 psf x 1.11 11.1 psf 11.1 psf PV Dead Load =. t • ` ,, PV-DL , 3.0 psf, . , . x 1.11 3.3 psf , - Roof Live Load RLL 20.0 psf x 0.90 18.0 psf Live/Snow Load „ ' . , LL/SL172 , 20.0_psf _x:0.84 I x.0.84 :- 16.8 psf, 16:8 psi,•T,. Total Load(Governing LC) - TL - 27.9 psf 31.3 psf Notes: 1. ps=Cs*pf;Cs-roof,Cs-pv per ASCE 7[Figure 7-2] 2. pf=0.7(Ce)(CO(Is)Pg; =IS 1.0 . _ Member Design Summa .(per'NDS) Governing Load Comb` CD CL(+) , -CL(-) CF Cr D+S 1.15 1.00' 0.52 1.3 1.15 - ` Member Analysis Results Summary ° ` 'Maximum Max Demand @'Location'- Capacity ` DCR ' Shear Stress 47 psi 1.2 ft. 155 psi 0.30 _ Bending(+)Stress - ' 1300-psi - • ,7.6 ft. , '. 1504 psi . -' 0;86 _ .-(Governs)-'•' Bending(-)Stress -49 psi _ 1.2 ft. -777 psi 0.06 Total'Load Deflection- 1.01 in.-I L/168 . 7.6 ft.. .. 1.42 in..[ 11120 0.71 w.,, Bending(+)Stress 1300 psi 7.6 ft 1504 psi 0.86 Pass , +.a LOADS ____ ____.____ .__ _.w,_____,_. _._t. �_i Mounting Plane Information , .' Roofing Material _ _ _ _ _ __ _ Comp Roof -�__._ __ ____ PV_System_,.Type ,,I__-________:_'____ ._ _. .. t. ._ ,_�__d__..:Solarcity SMo leekuntT" ®. _ _ � Spanning Vents _ No _ Standoff(Attachment Hardware), ::' 4,�.�r __. x rt Coma Mount Type C. ' . - , , _ Roof Slope �_ .— ._.,._.a". _ _n_ 26° _. .._______4, r__, Rafter_Spacing .w. ._ .."_,.,_. .__._"._..w,-_�..,.__._. _,..___. �.. ._W_,_.e�__... _. .16"OAC,__ ..;w_w _,,,_e .._ _.,.._� .,_...__._._.. Framing Type/Direction Y-Y Rafters Purlin Spacing_ __X-X Purlins Only__ NA __ ____ ______* ,,. Tile Reveal Tile Roofs Only_ NA_ Tile Attachment System _.. .y. ., _Tile Roofs Only ____,,__a.._,..-__,__,._w......,t. 'NA ...._., ,..� .. .; .,... ,.. _...,_ _d.w._ _ Standing Seam/Trap Spacing SM Seam Only NA Wind Design Criteria ° , �. . Wind_Design Code __ ASCE 7-05 K _ __ __ Wind Design Methdo7"---- __ __ - �_ _ -_ ' .,- Partially/Fully Enclosed Method' •_� '' Basic Wind SpeedV 120 mph __Fig. 6-1 Exposure Category ,.x...__ - ._. .y'..,v .''w. .. - W _,. ms.,..,µ.,.-77 ~ •C _.„_W,�....... ...", __7-77_,,....Section 6563 Roof Style _ Gable Roof Fig.6-11B/C/D-14A/B Mean Roof Height - -- -7--- _ — - — 'hµ .77-7_777-7--- 7—_ �_--� - :15-1E---- _ Section 6.2 Wind Pressure°Calculation CoefficientS - - _ Wind Pressure Exposure _ _� KZ_ 0.85 __ _ _ __Table 6 __.„,_: ___ __:)..,op Wind Directionality Factor Kd 0.85Table 6-4 Importance Factors . __ ; t__. , -. -I_ , . ,;_.-.�---„-777 _ _—77-7 1- .0_ . _ ..._,.. . `Table 6-1,_, ,. Velocity Pressure Chi qh = 0.00256(Kz)(Kzt)(Kd)(V^2)(I) Equation 6-15 26.6 psf Wind Pressure Ext. Pressure Coefficient(Up) GC,(Unl -0.88 Fig.6-11B/C/D-14A/B Ext.Pressure.Coefficient(Down) z. GCodmwn) ' ,, 0'.45 , Fig.6-11B/C/D44A/B Design Wind Pressure p p =qh(GC„) Equation 6-22 Wind Pressure Up Nilo) _ -23.3 psf Wind Pressure Down p(downl 12.0 psf [ALLOWABLE STANDOFF SPACINGS"__._____________._ _,_�____�_ ____________ X-Direction ' '- Y-Direction Max Allowable Standoff Spacing Landscape __ 64”64" 39" Max Allowable Cantilever__,___. ._____.,_ .. Landscape_L.,_.-_,_ ._a_-_.._.._,__, . _ 24° z ' ,-_ NA `,_..._ Standoff Configuration Landscape Staggered Max Standoff Tributary Area' `_�__'_ _ Trib -_:' `: —. ' v ' " 17 sf PV Assembly Dead Load -W-PV3.0 psf Net Windplift at Staw _. .� ryUndoff. . _,_„_,.T-,.actu ;e_al _.7,72,..777.77.7.1._-376 lbs,-W ...� W_.. ... _ _ __ .. _.._.__,_.'u. . .._— Uplift Capacity of Standoff T-allow 500 lbs Standoff Demand/Capacit'V . ' DR -C - 75.2% .- - ' • u, _" --_- X-Direction Ar-Direction Max Allowable Standoff Spacing Portrait 48" 65" Max Allowable Cantilever _ - Portrait _ -___T----. --- 18"_ _. _ _NA y_ Standoff Configuration Portrait Staggered Max Standoff Tributary_Area:..L_..___.-._ :I:O: _,._,_i 7'_ --- .:"m__-. ____,22`4 �_y 4�.�..___2 .v,�.�_� ."_ ,',.w�._ ._v._.__.._,. PV Assembly Dead Load _ W-PV — _ µ� 3.0 psf _a „_4 Net Wind Uplift at Standoff ,_ __ . _____al_ __ __. __Y -469 lbs _ ______ ___ ,�_ Uplift Capacity of Standoff T-allow 500 lbs Standoff Demand/Capacity'. DCR• y ,.. 7777 93:800"" 77'f" ","7,."7 ABBREVIATIONS . ELECTRICAL NOTES JURISDICTION NOTES • A AMPERE - 1. THIS SYSTEM IS GRID-INTERTIED VIA A ,S AC ALTERNATING CURRENT . UL-LISTED POWER-CONDITIONING INVERTER. ��SPE©TION RE© IRED ' ���D ITIr�ALL CODE ®�11 BLDG BUILDING - 2. THIS-SYSTEM HAS NO BATTERIES, NO UPS. ��W ������� ®��: ®®�� CONC CONCRETE - -3. - A NATIONALLY-RECOGNIZED TESTING AS R[sQUdRE® A CONDITIONS O OF DC DIRECT CURRENT - LABORATORY SHALL UST ALL EQUIPMENT IN EGC EQUIPMENT GROUNDING CONDUCTOR COMPLIANCE WITH ART. 110.3. APPRO ED AS NO' ED .s e e-few-z-ak-- (E) EXISTING 4. WHERE ALL TERMINALS OF THE DISCONNECTING EMT ELECTRICAL METALLIC TUBING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, 3 FSB FIRE SET-BACK A SIGN WILL BE PROVIDED WARNING OF THE DATE: $.P.#_- • , �; 7 GALV GALVANIZED HAZARDS PER ART. 690.17. n i ..,,,. , ==. W�, GEC GROUNDING ELECTRODE CONDUCTOR 5. EACH UNGROUNDED CONDUCTOR OF THE FEE 5 t [J( JBY: __ +1�_ GND GROUND MULTTWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY NOTIFY BUILDING DEPARTME ,T AT , HDG HOT DIPPED GALVANIZED . PHASE AND SYSTEM PER ART. 210.5. 765-1802 8 AM TO 4 PM FOR THE I CURRENT 6. CIRCUITS OVER 250V TO GROUND SHALL FOLLOWING INSPECTIONS: Imp CURRENT AT MAX POWER COMPLY WITH ART. 250.97, 250.92(B). 1. FOUNDATION - TWO REQUIREDIsc SHORT CIRCUIT 7. DC (� E kVA KILOVOLT AM E EURRENT BUILDING OR NARE ROURN INT THER META LIDO NOTC R RACEWAYS OR 2. ROUGH -ENTER FOR FR MINGEDC&PLUMBING OCCUPANCY OR kW KILOWATT ENCLOSURES TO THE FIRST ACCESSIBLE DC 3. INSULATION USE A� A fl9. UL LBW LOAD BEARING WALL DISCONNECTING MEANS PER ART. 690.31(E). 4. FINAL - CONSTRUCTION MUST �J l�JA 41VIf MIN MINIMUM 8. ALL WIRES SHALL BE PROVIDED WITH STRAIN BE COMPLETE FOR C.O. WI--10LT CERTOFOCATE (N) NEW RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY ALL CONSTRUCTION SHALL MEET THE �a Y p U NEUT NEUTRAL UL LISTING. REQUIREMENTS OF THE CODES OF NEW OF OCCJP ICY NTS NOT TO SCALE 9. MODULE FRAMES SHALL BE GROUNDED AT THE OC ON CENTER UL-LISTED LOCATION PROVIDED BY THE YORK STATE. NOT RESPONSIBLE FOR RETAIN STORM WATER RUNOFF PL PROPERTY LINE MANUFACTURER USING UL LISTED GROUNDING DESIGN OR CONSTRUCTION ERRORS. PURSUANT TO CHAPTER UN P01 POINT OF INTERCONNECTION HARDWARE. 236 PV PHOTOVOLTAIC 10. MODULE FRAMES, RAIL, AND POSTS SHALL BE OF THE TOWN CODE. SCH SCHEDULE BONDED WITH EQUIPMENT GROUND CONDUCTORS. S STAINLESS STEEL STC STANDARD TESTING CONDITIONS TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT Vmp VOLTAGE AT MAX POWER VICINITY MAP INDEX Voc VOLTAGE AT OPEN CIRCUIT W WATT ---- r PV1 COVER SHEET 3R NEMA 3R, RAINTIGHT ! �v _ r ,it';; • 1„ Ns l I '�'# , PV2 SITE PLAN x: 4 , g• N.,.,,,. -- C� � �- PV3 STRUCTURAL VIEWS PV4 UPLIFT CALCULATIONS LICENSE GENERAL NOTES ? , � ' � ` ``,`� ` PV5 THREE LINE DIAGRAM is 1,, p Cutsheets Attached 1. ALL WORK SHALL COMPLY WITH THE 2010 ' a , ` N. %, ; . -e, 4- ,'` v 2. ALL ELECTRICAL WORK SHALL COMPLY WITH . , - "r ;,;'�' , ' I THE 2008 NATIONAL ELECTRIC CODE. . . . .. _` ' R ' - j ,` MODULE GROUNDING METHOD: ZEP SOLAR " ...,icro-r .1, .01' Zi, Z,- ' -- HI - AHJ: Southold Town " F*.... , - . '''N- A:. I•REV BY DATE COMMENTS s` 4 mum DATE COMMENTS , _.. 4'4 wry" r ., ©©© UTILITY: PSE&G-Long Island (Public Service Electric b p 0 dee °' ms ""•-�� ©© . & Gas Co.) In e I = aIGobe, New York.,, I ' , U :1).A Fara ;Ser�vlce Ageji ;A©©© . J B-119508 0 0 PREMISE ONNER: DESCRIPTION: DESIGN: CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: N CONTAINED SHALL NOT BE USED FOR NE BEEBE, CONSTANCE R BEEBE RESIDENCE Sangita Sharma ;5®�arCity BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: NOR SHALL IT BE DISCLOSED IN %HOLE OR IN Comp Mount Type C 24925 NEW YORK 25 7.02 KW PV ARRAY PART TO OTHERS OUTSIDE NE RECIPIENTS MaDU1ES CUTCHOGUE NY 11935 TMK OWNER:* ORGANIZATION, EXCEPT IN CONNECTION WITH 3055 ClearAew Way THE SALE AND USE OF THE RESPECTIVE (27) TRINA SOLAR # TSM-260PD05.18 NM: * PAGE NAME SHEET REV: DATE: San Mateo,CA 94402 SOLARCITY EQUIPMENT, WITHOUT NE WRITTEN QIVLRTR: T:(650)638-1028 F:(650)638-1029 PERMISSION OF SOLARCITY INC. POWER-ONE ; AURORA PVI-5000-OUTD-US 6314781874 COVER SHEET PV 1 4/7/2015 (688)—SCI.—CITY(765-2489)www.soIarcity.cam PITCH: 26 ARRAY PITCH:26 MP1 AZIMUTH:140 ARRAY AZIMUTH:140 MATERIAL:Comp Shingle STORY: 1 Story ' L'1 M WORK-SHOP , (4,4jcz.fs:,6,F;N.E01//:,61'N. . • LEGEND p 7j1 , W)I • _ • + °MPI o • • • _ r t{`S 2/ \a+ p// Q (E) UTILITY METER & WARNING LABEL FE4,9 R 0e0605 P�0, INVERTER W/ INTEGRATED DC DISCO ��FESSION/ ® & WARNING LABELS its DC DC DISCONNECT & WARNING LABELS AC ® AC DISCONNECT & WARNING LABELS D Q DC JUNCTION/COMBINER BOX & LABELS Q DISTRIBUTION PANEL & LABELS - • 0 LG LOAD CENTER & WARNING LABELS (I) ❑� O DEDICATED PV SYSTEM METER Y ITl 0 STANDOFF LOCATIONS ® CONDUIT RUN ON EXTERIOR ®®o CONDUIT RUN ON INTERIOR — GATE/FENCE Q HEAT PRODUCING VENTS ARE RED t� INTERIOR EQUIPMENT IS DASHED (E)DRIVEWAY 1._-_,.'_i 24925 kw Yak 25 SITE PLAN *, 4, Scale: 3/32" = 1' e • 01' 10' 21' r F CONFIDENTIAL— NE INFORMATION HEREIN JOB NUMBER: PREMISE OWNER DESCRIPIIQN: DESIGN: ZSoIarCity JB-119508 00 BEEBE, CONSTANCE R BEEBE RESIDENCE g CONTAINED SHALL NOT BE USED FOR THE San ita Sharma � ; BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: "$ NOR SHALL IT BE DISCLOSED IN %HOLE OR IN Comp Mount Type c 24925 NEW YORK' 25 - 7.02 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENT'S MODULES: CUTCHOGUE, NY 11935 ORGANIZATION, EXCEPT IN CONNECTION WITH 3055 Clearview Way THE SALE AND USE OF NE RESPECTIVE (27) TRINA SOLAR # TSM-260PD05.18 g1 REY DATE San Mateo,CA 94402 SOLARCITY EQUIPMENT, WITHOUT THE WRITTENNvEREit PAGE NAME: 1:(650)638-1028 F:(650)638-1029 PERMISSION OF SOLARCITY INC. POWER–ONE # AURORA PVI-5000–OUTD–US 6314781874 SITE PLAN PV 2 4/7/2015 (888)—SOL—CITY(765-2489)wwa.eolarcIty.awn , J`• II ' 0 12'-9" 1'—Al (E) LBW SIDE VIEW OF MP1 NTS A MP1 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES LANDSCAPE 64" 24" STAGGERED PORTRAIT 48" 18" - ROOF AZI 140 PITCH 26 RAFTER 2x6 @ 16" OC STORIES: 1 ARRAY AZI 140 PITCH 26 C.J. 2x8 @32" OC Comp Shingle ,`(�or. ,Of NE�I�� _ � �h_ W PV MODULE o 5141 W 5/16" BOLT WITH LOCK INSTALLATION ORDER �d O l & FENDER WASHERS LOCATE RAFTER, MARK HOLE fit:: 090805 P�'*,',//, ZEP LEVELING FOOT (1) LOCATION, AND DRILL PILOT \7FESSION ZEP ARRAY SKIRT (6) HOLE. (1416°11 - (4) (2) SEAL PILOT HOLE WITH POLYURETHANE SEALANT. ZEP COMP MOUNT C Ada INI W TANWEI iTIN `� 1� ZEP FLASHING C �`t�Witt � � (3) INSERT FLASHING. (E) COMP. SHINGLE e�I E.). PLACE MOUNT. (E) ROOF DECKING VALIWI— MEM INSTALL LAG BOLT WITH 5/16" DIA STAINLESS (5) (5) SEALING WASHER. STEEL LAG BOLT LOWEST MODULE SUBSEQUENT MODULESINSTALL LEVEIJNG FOOT WITH WITH SEALING WASHER 6?._ BOLT & WASHERS. (2-1/2" EMBED, MIN) - (E) RAFTER STANDOFF Scale: 1 1/2" = 1' CONFIDENTIAL— THE INFORMATIOJ B-119508 00 PREMISE OWNER: DESCRIPTION: DESIGN: INFORMATION HEREIN JOB NUNBER: ����;So�arCi■ CONTAINED SHALL NOT BE USEDBEEBE,FOR THE CONSTANCE R BEEBE RESIDENCE Sangita Sharma �:�,`tty BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 24925 NEW YORK 25 7.02 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS NODULES: CUTCHOGUE, NY 11935 ORGANIZATION, EXCEPT IN CONNECTION WITH3055 ClearNew Way THE SALE AND USE OF THE RESPECTIVE (27) TRINA SOLAR # TSM-260PD05.18PAGE NAME SHEET: REV: DATE San Mateo,CA 94402 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN IN TER: T:(650)638-1028 F:(650)638-1029 PERMISSION OF SOLARCITY INC. POWER—ONE # AURORA PVI-5000—OUTD—US 6314781874 STRUCTURAL VIEWS PV 3 ww. 4/7/2015 (888)—SOL—CITY(765-2489)wsalarcity.com • ' GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND (N) #8 GEC TO (E) GROUND ROD Panel Number:SquareD QOC4OUF Inv 1: DC Ungrounded INV 1—(1)POWER—ONE ## URORA PVI-500 —OU —US LABEL: A —(27)TRINA SOLAR ## TSM-260PD05.18 AT PANEL WITH IRREVERSIBLE CRIMP Meter Number:23348135 Inverter (-21)111); 5000W, 277V/240V/208V, 96.5%/96.5%/96% PV Module; 260W, 236.9W PTC, 40MM, Black Frame, MC4, ZEP, 1000V Overhead Service Entrance INV 2 Voc: 38.2 Vpmax: 30.6 INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER E 200A MAIN SERVICE PANEL E 200A/2P MAIN CIRCUIT BREAKER ADJUST MIN. ACTIVATION VOLTAGES! SolarCity (E) WIRING CUTLER—HAMMER Inverter 1 INDn A 1 200A/2P Disconnect CO POWER—ONE �' Dc. Vstart= 120V AURORA PVI-5000—OUTD—US DC- _ MP 1: 1x9 _ * __ J 4 •R (E) LOADS B _ _ ■ ____ _ EGC t. • /� - - A LI KM 1— i v T L WC+ Vstart= 120V MI m • • I N Z..� DC- I I 4 C" '�, 30A/2P A may_---- GND�_ EGC! - ._ DDG rI • ) c. MP 1: 2x9 ii m m �� V DEC `._ 1 �C- B r GND I----EGC--- +--.__.. _---- ---- r�GC 1 - Vv , I I (1)Conduit Kit; 3/4'EMT - N __l__ I , _ 1 J EGC/GEC J Z—lc' _---GEC -_� TO 120/240V I ' SINGLE PHASE I U11UTY SERVICE II • I _ _l— - EGC ON ROOF TO BE ROUTED WHERE NOT SUBJECT TO PHYSICAL DAMAGE. WHEN ROUTED SUBJECT TO PHYSICAL DAMAGE THE SIZE MUST BE INCREASED TO #6 SOUD BARE - COPPER. - Voc* = MAX VOC AT MIN TEMP - p Yq POI�(1) Breaks D_1 Q0230 PV BACKFEED BREAKER B 1--(1)(11.111R-HAMMER#4OVac,DG221URB A C A 1-(-)S2x2 SiR1NGS,SUNIFUSEDDNGROUNDEDX DC Breaker A 2P, 2 Spaces Plug-On Disconnect; 30A,#240Vac, Non-Fusible,NEMA 3R -(1) Ground/NeutraltralKit; 30A, General Duty(DG) Ilf (1)AWG#10, THAN-2,Black —(1)AWG#10, 1HWN-2, Black Voc* =387.81 VDC Isc =18 ADC —(2)AWG#10, PV WIRE, Black Voc* =387.81 VDC Isc=9 ADC ©I—(1)AWG#10, 1HWN-2,Red ® 4-(1)AWG#10, THWM-2, Red Vmp =275.4 VDC Imp=17 ADC ...Th ----1— rg-(1)AWG#6, Solid Bare Copper EGC Vmp =275.4 VDC Imp=8.5 ADC LLLL�=_=CELL(1)AWG#10, THWN-2,White NEUTRAL Vmp =240 VAC Imp=23 MC --(1)AWG 110, IHWN-2, Green EGG .. -.(1)AWG#8, 1HWN-2,Green.. EGC/GEC, (1)Conduit.Kit; 3/4"EMT.... cn (1)AWG#10, IHWN-2,Black Voc* =387.81 VDC Isc=9 ADC (4)AWG#10,PV WIRE, Black Voc* =387.81 VDC Isc=9 ADC O 4-(1)AWG#10, THWN-2,Red -Vmp =275.4 VDC, Imp=8.5 ADC O ! (1)AWG#6,Solid Bare Copper EGC Vmp =275.4 VDC Imp=8.5 ADC (i)AWG 110, THWN-2,Green. EGC • .. _ —(4)AW6#10, PV WIRE, Black Voc* 387.81.. 3 VDC Isc=9 ADC -(1)AWG#6, Solid Bare Copper EGC Vmp =275.4 VDC Imp=8.5 ADC CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER JB-119508 0 0 PREMISE OWNER: DESCRIPTION: DESIGN: `BEEBE, CONSTANCE R BEEBE RESIDENCE 9 SolarCity CONTAINED,SHALL NOT BE USED FOR NE San ita Sharma : BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: �'�" NOR SHALL IT BE DISCLOSED IN WHOLE OR IN CompMount Type C 24925 NEW YORK 25 7.02 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENT'S MODULES: CUTCHOGUE, NY 11935 ORGANIZATION, EXCEPT IN CONNECTION WI1H 3055 aearview Way THE SALE AND USE OF THE RESPECTIVE (27) TRINA SOLAR # TSM-260PD05.18 �: REV ppR San Mateo,CAe 94402y SOLARCITY EQUIPMENT, VATHOUT THE WRITTEN U1Vm7ER PAGE NAME T:(650)638-1028 F:(650)638-1029 PERMISSION OF SOLARCITY INC. POWER-ONE # AURORA PVI-5000-OUTD-US , 6314781874 THREE • LINE DIAGRAM PV 5 4/7/2015 (888)-SOL-CITY(765-2489)www.solarcIty.com WARNING:PHOTOVOLTAIC POWER SOURCE Label Location: Label Location: Label Location: (C)(CB) WARNING (AC)(POI) WARNING (DC)(INV) Per Code: Per Code: Per Code: ELECTRIC SHOCK HAZARD ELECTRIC SHOCK HAZARD NEC 690.31.G.3 DO NOT TOUCH TERMINALS NEC 690.17.E THE DC CONDUCTORS OF THIS NEC 690.35(F) Label Location: TERMINALS ON BOTH LINE AND PHOTOVOLTAIC SYSTEM ARE TO BE USED WHEN PHOTOVOLTAIC DC (DC) (INV) LOAD SIDES MAY BE ENERGIZED UNGROUNDED AND INVERTER IS IN THE OPEN POSITION MAY BE ENERGIZED DISCONNECT Per Code: UNGROUNDED NEC 690.14.C.2 Label Location: Label Location: PHOTOVOLTAIC POINT OF (PO1) INTERCONNECTION Per Code: MAXIMUM POWER _A (DC) (INV) WARNING: ELECTRIC SHOCK. POINT CURRENT(Imp) Per Code: HAZARD, DO NOT TOUCH NEC 690.17.4; NEC 690.54 MAXIMUMVOLTAGE POWER- POINT (Vm Ep) POINTT VOL_V NEC 690.53 TERMINALS.TERMINALS ON MAXIMUM SYSTEM BOTH THE LINE AND LOAD SIDE VOLTAGE(Voc)_V MAY BE ENERGIZED IN THE OPEN SHORT-CIRCUIT POSITION. FOR SERVICE CURRENT(Isc)_A DE-ENERGIZE BOTH SOURCE AND MAIN BREAKER. - PV POWER SOURCE - MAXIMUM AC A OPERATING CURRENT MAXIMUM AC V Label Location: OPERATING VOLTAGE WARNING (DC)(INV) Per Code: ELECTRIC SHOCK HAZARD IF A GROUND FAULT IS INDICATED NEC 690.5(C) NORMALLY GROUNDED Label Location: MAY BE UNGROUNDEDORS AND ENERGIZED CAUTION (P01) DUAL POWER SOURCE Per Code: SECOND SOURCE IS NEC 690.64.B.4 PHOTOVOLTAIC SYSTEM Label Location: WARNING (DC)(CB) • ELECTRICAL SHOCK HAZARD Per Code: Label Location: DO NOT TOUCH TERMINALS NEC 690.17(4) CAUTION (D)(P01) TERMINALS ON BOTH LINE AND - Per Code: LOAD SIDES MAY BE ENERGIZED PHOTOVOLTAIC SYSTEM IN THE OPEN POSITION CIRCUIT IS BACKFED NEC 690.64.6.4 DC VOLTAGE IS ALWAYS PRESENT WHEN SOLAR fv1ODULES ARE EXPOSED TO SUNLIGHT Label Location: WARNING (P01) Per Code: INVERTER OUTPUT Label Location: NEC 690.64.B.7 CONNECTION PHOTOVOLTAIC AC (AC)(P01) DO NOT RELOCATE (AC):AC Disconnect Per Code: THIS OVERCURRENT (C): Conduit DISCONNECT DEVICE NEC 690.14.C.2 (CB): Combiner Box (D): Distribution Panel (DC): DC Disconnect (IC): Interior Run Conduit Label Location: (INV): Inverter With Integrated DC Disconnect MAXIMUM AC _ A (AC)(P01) (LC): Load Center OPERATING'CURRENT Per Code: (M): Utility Meter MAXIMUM AC v NEC 690.54 (P01): Point of Interconnection OPERATING VOLTAGE CONFIDENTIAL– THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR -064 3055 Gearview Way T.(650)636-1028 F.(650)6384029 THE BENEFIT OF ANYONE EXCEPT SOLARa IY INC.,NOR SHALL IT BE DISCLOSED .4.-,,„.s... San IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, Label Set /�` San Mateo,CA 94402 01��'� (888)-SOLCI Y(765-SOL EXCEPT IN CONNECTION WIN THE SALE AND USE OF THE RESPECTIVE o SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. / • u. SOIarCity Z pSolar Next-Level PV Mounting Technology '5OIarCity I Z pSolar Next-Level PV Mounting Technology Zep Systemili Components for composition shingle roofs =- '''' ;'''''.:Aip-roof ,..-.2---, IL Q . -i.--14 .--.A. - Ground Zep - _ TnteMck psysdestcen) - - - `_ ---_ - Leveling rbet _ \ . , • c� „S — \ mss. • p Compal ble PV Module - " ! ` ----' Zep Groove _ �� `' — Roof Attachment ''"' _ _ lr`! Array Skirt S - ` - : . r,- ▪ ®e(• m Description � "' � 7, • PV mounting solution for composition shingle roofs \�� �t �A-omoss • Works with all Zep Compatible Modules ��) �= �t Ir= • Zep System UL 1703 Class A Fire Rating for Type 1 and Type 2 modules • Auto bonding UL-listed hardware creates structual and electrical bond LISTED Comp Mount Interlock Leveling Foot Part No.850-1345 Part No.850-1388 Part No.850-1397 Listed to UL 2582, Listed to UL 2703 Listed to UL 2703 Specifications Mounting Block to UL 2703 • Designed for pitched roofs i- 7 • Installs In portrait and landscape onentatlons • Zep System supports module wind uplift and snow load pressures to 50 psf per UL 1703 \II • Wind tunnel report to ASCE 7-05 and 7-10 standards ``i� 4 • Zep System grounding products are UL listed to UL 2703 and ETL listed to UL 467 Nall. • Zep System bonding products are UL listed to UL 2703 `� t • Engineered for spans up to 72"and cantilevers up to 24" • Zep wire management products listed to UL 1565 for wire positioning devices Ground Zep Array Skirt,Grip,End Caps DC Wire Clip • Attachment method UL listed to UL 2582 for Wind Dnven Rain - Part No.850-1172 Part Nos.500-0113, Part No.850-1448 - Listed to UL 2703 and 850-1421,850-1460, Listed UL 1565 ETL listed to UL 467 850-1467 zepsolar.com zepsolar.com Listed to UL 2703 This document does not create any express warranty by Zep Solar or about Its products or services.Zep Solar's sole warranty is contained in the written product warranty for This document does not create any express warranty by Zep Solar or about its products or services.Zep Solar's sole warranty is contained in the written product warranty for each product.The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty The customer is solely each product The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty The customer is solely responsible for venfying the suitability of Zep Solar's products for each use.Specifications are subject to change without notice Patents and Apps zspats corn responsible for verifying the suitability of Zep Solar's products for each use.Specifications are subject to change without notice Patents and Apps zspats com 12 22 14 ZS for Comp Shingle Cutsheet Rev 02 pdf Page: 1 of 2 12 22 14 ZS for Comp Shingle Cutsheet Rev 02 pdf Page: 2 of 2 . . '''N. P011/0f-Onee AURORA . _. 1 II ‘.1 Renewable Energy Solutions TECHINreAL,DATA ' ;, WM119g .! PVI-5.000-OUTEMOS PA-t1-6000-CIUTD-US Nominal Output PowerW 5000 6000 Maximum Output Power.... ........ : .......W : 5000 i 6000 Rated Grid ACVoltage V . 208 I 240 277 208 ' 240 277 , . --, _ Number of Inilependent MA'AT Channels 2 - . 2 ,:. .„ , . Maximum Usable Power for Each Channel w , 4000 Absolute Maximum Voltage(Vmax) V 4000 600 . 600 ,..,„ 200 (adj 120-350) Start-Up yoltege(Vstart) V 200 (ad)120-350) Plilji=6;000—71. . , . . :; , , Full Power MPPT Voltage Range _Operating MPPTVoltage Range V V : . • 200-530 0 7xVstart-580 1 200-530 0 7xVstart-580 , ' Maximum Current(Idcmax)for both MPPT in Parallel A * 36 36 -•i;': Maximum Usable Currentper Channel A 18 T 18 •• A 22 : 22 GENERAL SPECIFICi8kTIONS _ 'i- -_:-:_ • Maximum Short Circuit Current Limit per Channel Number°Mire Landing Terminals Per Channel 2 Pairs , . • 2 Pairs OUTDOOR MODELS ., ,c'd'.:' - --' -,... Array Wiring Termination ltputSlele(AC)' 7-- = _1 2 Terminal block,Pressure Clamp AWG8-AWG4 TJ ' Grid Connection Type i 10/2W • Split-0/3W ' 10/2W " 10/2W , Split-0/3W I 10/2W AdjustableVoltage Range(Vmin-Vmax) J V . 183-228 . 211-264 I 244-304 1 183-228 : 211-264 , 244-304 - : Grid Frequency Hz 60 60 .. Adjustable Grid Frequency Range Hz : ' 57-60 5 57-605 Maximum Current(lacmax) 1 kw . 27 , 23 : 20 • 30 ' 28 • 24 4 Power Factor : , >0995 , >0 995 . ) Total Harmonic Distortion At Rated Power % <2 ' <2 : Contributory Fault Current** • A k/Ams 36 25/25 63 " 36 5/25 81 ; 31 75/22 45 ' 36 25/25 63 36 5/25 81 31 75/22 45 - -., [=%• , 1'-:-1,•",, Designed fbi-,res'identigard small'cdmniercial p*installaiions,i!,11,is,,-," , '-:$ ' , ... „ , '.4-. ' -' , A ° , ; Grid Wiring Termination Type Terminal block,Pressure Clamp AWG8-AWG4 „ — .- ", , - inverter fills a specific niche in the Aurora product line to'cater for' 7-4. -I; , ; [Protection Devices . • ,. , : -,, - ____,-__—. _ „_._1 1 Ilnput 1 : -•":1:,:,• those installationSpruducin,g between,SkW and zpkvy.--r ' , ' :I; -.' ', . ,,,, ,,.„,,,. ,' ,,,‘ ' * -.,' , ,.4^, ', -, ,-, , ', ./- ere' ''' ' ' 1 Reverse Polarity Protection Yes I Yes ,......:.u....... IR Over-Voltage Protection Type . Vanstor,2 for each channel Vanstor,2 for each channel " 1 ' Pre start-up RI50 and dynamic GFDI : Pre start-up Riso and dynarinc GFDI This inverter has all-the usual Aurora benefits,ifieluding dual input PV Array Ground Fault Detection :,1 - (Requires_Floating Apays) (Requires Floating Arrays) section to process two strings with independent MPPT,high speed,i ,-,, ' ' i,i ' l.'._3.1.-_,.„,„-.:.1..., , "1 .Otitput - .' - 7 I - Anti-blending Protection .: Meets UL 1741/1EE1547 requirements ' Meets UL 1741/IEE1547 requirements and precise MPPT algorithm for real-time.porker tracking and ' -% .= ., 11'. A , l): . „ , - Over-Voltage Protection Type ' T Vanstor,2(I,-I,/I,-G) 25 40 Vanstor,2(I.,-L2/I,-G) energy harvesting .as well as transformerle,ss",operation for,high .=,,--= .'') I ' , ' ,1 i , Maximum AC OCPD Rating 1 : 35 : 30 ' ' = perfOrmance'efficiencies dup to§7.1%. - -UNO ' - . ' a Maximum Efficiency : % , 97.1 971 ,.- :: ""rh1 Ailde input voltage"range makes dinVerter suitable tO4ow , - . power installations with reduced string size This outdoor inverter - _ Ti s,. 1 ' ' ' '-1 ..„ -ri : ESPerellii Pe ikriii ali ce -1_,,„ , , Stand-by Consumption , <8 <8 <0 6 has'been designed as a completely,sealed,unii"=t0 Withstand the „,.., ,. .,,,,I.h , '. ., , 1 . „ - 1 Nightumeconsurilption ____ ___ ,'., wp,,,, , <9.6 ijeeinintinicatia '' ' 17'1 -1' [-- -- -4- harshest environmental conditions.-- - , :1, _, , T. ' '‘,-.1-4..:,..s.-22,.-'- ' `-1 ;- ''''i ,__ _is 4 ' - 1 User Interface Remote Monitoring SURS485 incl) I 1, 16 characters x 2 lines LCD display AURORA-UNIVERSAL(opt) . a ' , _ , .,,,-- ,,,' , • , "9" -0-4 1, '' '1 "'"-, ""' :"': " -' "" - " '';.: ' :11I; ,, : L ,. ,J Wired Local Monitoring(1xRS485 incl.) I ; PVI-USB-RS485_232(opt),PVI DESKTOP(opt) ' " ' = . .. . : L - , , -:- 2 Wireless Local Monitoring PVI-DESKTOP(opt)with PVI-RADIOMODULE(opt) - _ ( - :):P ' - sTkkx 501.4E2.. Lfipvironmental , 1=;" :'"" """" ' '• -',. , ':',".i...._,"-711" ""-1' , ' '' ""1,1- • '''',1,"=',..' ,' ''.',. ' '--;.il" ,. _. Ambient Air Operating Temperature Range ! °F(T) : -13 to+140(-25 to+60) with derating above 122(50) ,-, Ambient Air Storage Temperature Range ' F(C) -40 to 176(-40 to+80) -40 to 176(-40 to+80) -------- n 1 %RH _ _ _ _. Relative Humidity 0-100 condensing 0-106 condensing FeStlIEMZ . . ,: Acoustic Noise Emission Level Maximum Operating Altitude without Derating = ' db(A)@1 m 1, : ft(m) : <50 6560(2000) • <50 6560(2000) .i ,, Mechanise)Specifications , . - :, - :: In(mm) .: : , ,.., ,,,_ Enclosure rating -NEMA 4X- , NEMA 4X I Cooling Natural Convection Natural Convection •,Each inverter is Set on specific grid codes which can be selected in the field ' _ - -- - , - - = t Dimensions(H xWx D) 414x 128 x 8.6(1052x 325 x218) - "j` 21 IN'Single pi-r'ae output ' t. ''' , , , ,,. , ., Weight <59.5(27 0) <59.5(27 0) '•-'' :4, - : -1: , -4: • ' ''' , '-• • Dual input sections with independent MPPT allows optimal energy harvesting from two sub Oriented. -- I Shipping Weight lb(kg) <78(35 4) <78(35 4) - ,--- - . Mounting System Wall bracket Wall bracket in different direCttons!,,,,, -' ,, -„, - - ...„. , '"-,- ,„ . , ,, .i . :CTrade Size Kos*(2ea x 1/21 : , Trade Size Kos:(2ea x 1/2") onduit Connections •Wide Input range, ''-,. - , ',, '. : ,'', ' -,...! -"' -- :- "- , '',g and(2ea x 1-1/41 3 places side,front rear) ; and(2ea x 1-1/4';3 places side,front rear) : w . : , t , •High speed and precise:MPPTajgorithrri for real time powertracking and improved energy harvesting DC Styitch Rating-(Per Contact) AP/ 25/600 25/600 1-Spfe ----r- . - _„ 4,Flat efficiency curves ensyre,high,efficiency at all outpUt levels ensuring consistent and stable performance ,, ; I Isolation Level • Transformerless(Floating Array) Transformerless(Floating Array) Safety and EMC Standard UL 1741 ; ,CSA-C2/2 N,107 1-01 : UL 1741,CSA-C222 N 107 1-01-- = across the entire input voltage and outptit power range '-_ ' -- , , - , ' 1 --,_ - , Safety Approval . •;'Outdoor enclosure for unrestricted use under any environmental,conditionS---, -2:. ,, ,, ' ,,,,;"4 , ', , .-- 1 t "---- .I'RS-485 communication interface(for connection to laptop or;;Iatalog'ger) . Staniard Warranty years ,' 10 10 : •p3mpatible with PVI-RADIQMODULE for'wireless comMunication with Aurora PVI-DESKTOP Extended Warranty_- lityallable Models -, ..—,- _:, - - years . 15&20 , - 15&20, _ -1 „ - - - , -• := :---= -- — Standard With DCSwitch-Floating Array : PVI-5000-OUTD-US ' PV1-6000-OUTD-LIS 'All data Is subject to change without notice , / - - - ••Inver can apply that much current-Breaker will open ,--„' ,,. .ADRORAglri E - - —- i rte4111111=111111111111101MMVANIVINNIME _ , J if'o CSA o w Group Certificate of Compliance - Certificate: 1841082 Master Contract: 173688 Project: 2550432 Date Issued: August 20,2012 Issued to: Power-One,Inc 740 Calle Plano Camarillo,CA 93012 USA Attention:Robert White The products listed below are eligible to bear the CSA Mark shown with adjacent indicators 'C'and 'US'for Canada and US or with adjacent indicator 'US'for US only or without either indicator for Canada only. Brij Aggurwc+,L Issued by: Brij Aggarwal,P.Eng. C US PRODUCTS CLASS 5311 09 -POWER SUPPLIES-Distributed Generation Power Systems Equipment CLASS 5311 89 -POWER SUPPLIES-Distributed Generation-Power Systems Equipment -Certified to U.S.Standards Utility Interactive Inverter,Models PVI-6000-OUTD-US,PVI-6000-OUTD-US-W and PVI-5000-OUTD-US, permanently connected. Notes: 1. All above models in this series may include expansion board with wireless antennae option and will be identified with model designation including"—Z"suffix at the end. - 2. For details related to rating,size,configuration,etc.reference should be made to the CSA Certification Record,Annex A of the Certificate of Compliance,or the Descriptive Report. DQD 507 Rev 2012-05-22 Page 1 . • I, ( ►,'; THE •Trinamount MODULE TSM-PD05.18' Mono M� Solutions I ?1 1:'1'1 ' l T II 1., � t I4!.`#j.:k r'`• I YI' DIMENSIONS OF PV MODULE ELECTRICAL DATA @ STC t I r rl'' . unit:mm Peak Power Watts-PMA%(Wp) 245 250 255 260 1 ��: • fI {I`.,. 941 Power Output Tolerance-PMA%(%) ; - 0-+3 t1-,- 1,-ri{•t, f i THE Tr.na m® V t ®t i r F 1 ,, • o Maximum Power Voltage-VMv(V) 299 303 305 306 } iiL {f F t •! PDX Maxim-um Power Current-IMry(A) 8 20 8 27 8 37 8 50 ('' •f i Y,; ; NAMEPLATE o 'Open Circuit Voltage-Voc(Vj 37 8 38 0 38 1 38 2 ii �• ' t i `..m°.a i Short Circuit Current-Isc(A) - 8 75 8.79 - 8 88 9 00 t } INSTALLING HOLE T } 1 i it u 'I ,Module Efficiency qm(%) ° 15 0 15 3 15 6 15 9 , MODULE tx ' ‘;c:--1-.i t STC Irradiance 1000 W/m',Cell Temperature 25 C,Air Moss AM1 5 according to EN 60904-3 j Typical efficiency reduction of 4 59 at 200 W/m'according to EN 609041 :t1 t( 1 1 1 II I N e 11 4 e c ,11• yy I I, (`tit - 'f-'t' ELECTRICAL DATA @ NOCT ti 60 CELL I-- a.ti (, ,Mawmum Power-PMA%(Wp) 182 186 190 193 • tilt Iktk is -'T'' I,MaximumPowerVoltage-VA,r(V) y 276 280 28.1 283 ,k kkk I •!t j Maximum Power Current-Ia (A) 6 59 6.65 6 74 6 84 - MULTICRYSTALLINE MODULE ,i 1 11' `°"°"°""°"°"°� A q ) , = WITH TRINAMOUNT FRAME '1'----:.1-.1...1I •• I I , - /u-MANHOLE (Open'Circuit Voltage(V)-V°c(V) 35 1 35 2 35 3 35 4 Ii w ` /7/J Short Circuit Current(A)-Isc(A) ! 707 710 717 727 - t _ - NOCT Irradiance al 800 W/m',Ambient Temperature 20"C,Wind Speed I m/s �, I 812 1180 245-260W PD05,18 - Back View POWER OUTPUT RANGE , MECHANICAL DATA - { �----. — 11 Solar cells ;Multicrystalline 156 x 156 mm(6 inches) �' l Fast and simple to install through dropin mountingsolution i p g ,Cell onenta4on T 60 cells(6 x 10) 11 5.9% Module } dimensions -1 1650 x 992 x 40 mm(64 95 x 39 05 x 1 57 inches) ® •�.� I Weight 213 kg(470lbs) - - _-- MAXIMUM EFFICIENCY Glass 3 2 mm(0 13 inches),High Transmission,ARCoafed Tempered Glass f---- — A-A ;Backsheet - -- - White - i If( ' Good aesthetics for residential applications Frame ;BIackAnodized AluminiumAlloywith TnnamountGroove O w% 4L { }J-Box "IP of65 or It 6i rated - Jl ,! I-V CURVES OF PV MODULE(245W) ) `�"��- Cables 'Photovoltaic Technology cable 4 0 mm'(0 006 inches'),-` 1000 1200 mm(47 2 inches) POWER OUTPUT`GUARANTEE9°° W{m' I Fre Rating Type 2 - t - Bm -� 800W/m' S—_ _ m--, - Highly reliable due to stringent quality control a 6°_6ww/� 1 • Over 30 in-house tests(UV,TC,HF,and many more) m 5" As a leading global manufacturer ` r E ) • In-house testing goes well beyond certification requirements _ u 400-400W/m' TEMPERATURE RATINGS MAXIMUM RATINGS of next generation photovoltaic 300 - - products,we believe close 3e_200W/m' Nominal Operating Cell ;44°C(±2°C) , Operational Temperature;-40-+85°C Temperature(NOCT) "' - i cooperation with our partners 1. Maximum System 1000V DC(IEC) l o°° A i Temperature Coefficient of PMA% •-0 41%/°C 1 Voltage , 1000V DC(UL) 1 is critical to success. With local + 040 1000 tow 301-0 4040 , { - presence around the globe,Trina isvoltage(v) Temperature Coefficient of Voc -0 32%/°C ,Max Series Fuse Rating , - 15A i able to provide exceptional service Tempera -v''» Certified to withstand challenging environmental ture Coefficient of Isc 0 OS%/°c-- , to each customer in each market 7----.2 --- and supplement our innovative, conditions t reliable products with the backing ,j, • 2400 Pa wind load WARRANTY of Trina as a strong,bankable • 5400 Pa snow load partner. Weare committed 10 year Product Workmanship Warranty to building strategic,mutually - , - - - ` - - -- - beneficial collaboration with 125 year Linear Power Warranty 1 ' installers,developers,distributors (Please refer to product warranty for details) a; and other partners as the _ backbone of our shared success in - - - - - - - - - - CERTIFICATION ' driving Smart Energy Together - LINEAR PERFORMANCE WARRANTY - PACKAGING CONFIGURATION g c III us °S�� Modules per box 26 pieces w 10 Year Product Warranty•25 Year Linear Power Warranty usrm _--_ - 2- j Trina Solar Limited www tnnasolar cam �' .. r ,:Modules per 40'container 728 pieces ._.-... - ;,loop g. Ip • 11,_ Ih1onovoIuefrofloSo,ars,, 90% o - rrOfily CAUTION READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT 01047.4 TF'1@�aSOlar O 8020 Trin'aSOlar 02014ewitSolar notice Allrights INSTAreserved Specifications - ._ ,"Y, j, f'u cP"' .+„,,..”, '+, change without notice Smart Energyjogether Smart Energy Together '�o° Years 5 10 15 20 25 II Tnnastandard I Incust•ystancard -