Loading...
HomeMy WebLinkAbout40440-Z Og4F04-coG-; Town of Southold 4/12/2016 e P.O.Box 1179 i» m;` 53095 Main Rd �,�:91,41:1,.„�2e�"g� Southold,New York 11971 114 f , CERTIFICATE OF OCCUPANCY No: 38222 Date: 4/12/2016 THIS CERTIFIES that the building GENERATOR Location of Property: 395 Oak Dr.,Southold SCTM#: 473889 Sec/Block/Lot: 80.-1-33 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 1/26/2016 pursuant to which Building Permit No. 40440 dated 2/1/2016 was issued,-and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: ACCESSORY GENERATOR AS APPLIED FOR The certificate is issued to Miller,Merritt of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 40440 03-31-2016 PLUMBERS CERTIFICATION DATED Authorized Signature ,r'" �: TOWN OF SOUTHOLD o`AsU���'�� : BUILDING DEPARTMENT .� y t o ? TOWN CLERK'S OFFICE oy a' SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 40440 Date: 2/1/2016 Permission is hereby granted to: Miller, Merritt 395 Oak Dr Southold, NY 11971 To: Install an accessory generator as applied for. At premises located at: 395 Oak Dr.,Southold SCTM # 473889 . Sec/Block/Lot# 80.-1-33 Pursuant to application dated 1/26/2016 and approved by the Building Inspector. To expire on 8/2/2017. Fees: ACCESSORY $100.00 ELECTRIC $85.00 CO -ACCESSORY BUILDING $50.00 A1: $235.00 I Pc 7r 1• �- • Or pita S®(/4 - Town Hall Annex �I �® (e) Telephone(631)765-1802 i 54375 Main Road % Fax(631)765-9502 P.O.Box 1179 ; .4 t 0 roger.richertatown.southold.ny.us Southold,NY 11971-0959 .,e.� •®�I • BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION Issued To: Miller Address: 395 Oak Drive City: Southold St: New York Zip: 11971 Building Permit#: 40440 Section: 80 Block: 1 Lot. 33 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: License No: SITE DETAILS Office Use Only Residential X Indoor Basement Service Only Commerical Outdoor X 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures HID Fixtures Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel _ NC Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel NC Blower Range Recpt Fluorescent Fixture Pumps Transformer Appliances Dryer Recpt Emergency Fixtures Time Clocks Disconnect Switches Twist Lock Exit Fixtures TVSS Other Equipment. 20 KW Stand By Generator with Automatic Transfer Switch Notes. Inspector Signature: e Date: March 31, 2016 Electrical 81 Compliance Form xls Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings,property lines, streets,and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal (S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains-less than 2/10 of 1% lead. 5. Commercial building, industrial building,multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings(prior to April 9, 1957)non-conforming uses,or buildings and"pre-existing" land uses: 1. Accurate survey of property showing all property lines,streets, building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant.If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00,Alterations to dwelling$50.00, Swimming pool$50.00,Accessory building$50.00,Additions to accessory building$50.00,Businesses$50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy-$.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy-Residential$15.00,Commercial$15.00 Date. UG,n, a( a o 16 New Construction: Old or Pre-existing Building: (check one) Location of Property: 9 (D (� Soo j i�Cj Ld House No. Street Hamlet Owner or Owners of Property: e r lER 6G 1 ( LE/ j &R( 2 6- }' r(\ I LLE,--� Suffolk County Tax Map No 1000, Section 0 Block Lot 41 '!; ,;;: 'f°"33 Subdivision F.E DO'13 &4MCS Filed Map. Lot: Permit No. 40''"( i o Date of Permit. Applicant: Health Dept.Approval: Underwriters Approval: Planning Board Approval: Request for: Temporary Certificate Final Certificate: (check one) FVV Fee Submitted: $ Applicant Signature wi , • n FflDLD II�'SPE QN 1ZEV'0 '� DATZ _, COUNTS ' " FOUND, ±ON(1ST) , --,----7.-- , . ' - ^� 1 FOUNDATION TIOr (MID) ---^-�-�- t4 ROUGES FI CA& ...-"`rte' PLU3ING ...� , .• M . .__. _ I ... • • 0 1111111 • • INSULATION PEA N,Y. '. H STATE ENERGY C0�3E , . y , . ' , . . s.. , . FINAL . . ,I . ?I ti. .4 - . • - • l �". , , .,. , • • • • • • • • o . z 6..�...., *am •. , • . ., 1 1. T,. ---- . , . . • v �—�—. IQ 35 . c).0 TOWN OF SOUTHOLD B' ii)60 • 06 BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT e ih-1 L- - 6° Do you have or need the following,before applying? TOWN HALLf� 11Jc0 . ad Board of Health i SOUTHOLD,NY 11971 C/" 4C ets of Building Plans TEL: (631) 765-1802 Planning Board approval FAX: (631) 765-9502 /� S�rvey SoutholdTown.NorthFork.net PERMIT'NO. V U Check Septic Form - N.Y.S.D.E.C. rustees n ' f' , C. .Application I f I' ii \:''If 1, lood Permit Examined 1 ,20412 f1 i I Single&Separate l ��N 2 I Storm-Water Assessment Form 6 2016 ��.il Contact: y�� �"" ApprovedPl 20 I ---' )4Ee1e/ 7 /s'/ /L�.LIZ 3LUG r)FPI / ? 7 Disapproved a/c - - T',�'���f,Or ;nl;,l1 n'r 43/ -76 g -. ,5 3 Phone: Expiration 2 / «I iviA , Buil'ing Inspecto APPLICATION FOR BUILDING PERMIT Date_ , 20 INSTRUCTIONS a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans, accurate plot plan to scale.Fee according to schedule. b. Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. - f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize,in writing,the extension of the permit for an addition six months. Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York, and other applicable Laws,Ordinances or Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances,building code,housing code,and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. (Signature of applicant or name,if a corporation) (Mailing address of applicant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder OW0E_k_ Name of owner of premises I Y l 617,a t l 1 LLE-f2_ (As on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer (Name and title of corporate officer) Builders License No. ' Plumbers License No. Electricians License No. q 3`1 - 4‘ Other Trade's License No. - 1. Location of land on whio1h-proposed:work will;be dpne.:s-;i ' 9 0 n K. ,r.,; .s�,: ... . ..0 LI I l 1D LSI, , " House Number Street:,.,;,;' -'-' , ,`-', " , Hamlet - w. County Tax Map No. 1000 Section C(O Block 0, a Lotikir 33 (--" Subdivision E- Q(s,I3 Q/'l,64 Filed Map No. Lot 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy b. Intended use and occupancy _ 3. Nature of work(check which applicable):New Building Addition Alteration Repair Removal Demolition Other 'ork , I v "NW ! ' (Description) 4. Estimated Cost Fee (To be paid on filing this application) 5. If dwelling, number of dwelling units Number of dwelling units on each floor If garage, number of cars 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of existing structures, if any: Front Rear Depth Height Number of Stories Dimensions of same structure with alterations or additions: Front Rear Depth Height Number of Stories 8. Dimensions of entire new construction: Front Rear Depth • Height Number of Stories 9. Size-of lot: Front Rear Depth 10. Date of Purchase Name of Former Owner 11. Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law, ordinance or regulation? YES NO 13. Will lot be re-graded? YES NO Will excess fill be removed from premises? YES NO 14.Names of Owner of premises Address Phone No. Name of Architect ,\ Address ' Phone No Name of Contractor Ps\1 Ul)vcct'►A`_ SketiritG Address t 7,%' eiovalea Phone No( 31 ) 3 5'Z —Z9 L 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO * IF YES, SOUTHOLD TOWN TRUSTEES & D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey, to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. 18. Are there any covenants and restrictions with respect to this property? * YES NO * IF YES, PROVIDE A COPY. STATE OF NEW YORK) SS: COUNTY-OF ) being duly sworn, deposes and says that(s)he is the applicant �ame-o in ividual signin contract)above named, (S)He is the 6 (,..1-7-1-Q-(--- (Contractor,Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be performed in the manner set forth in the application filed therewith. CAROL HY)ELL Sworn to before me this NOTARY PUBLIC-STATE OF NEW YORK day of ., ,k i..a+ NO.01 HY6189695 FP vs! , � , QUALIFIED IN SUFFOLK COUNTY v/ COMMISSION EXPIRES 061301201 Nota P .h, , Signature of Applicant • • • RR ' AoV SOU- -- • - town X-fall Annex! ; 45 y.• f . if Telephone(631)79,G5--1842 �' S437.5 Main lioad; % crr .-' " '' ; rocler-richertown SORSLi50inV_Us P_).Box 1179 : • + Southold,NT 11971-6,959 O �O�l� , BUMMING DEPARTMENT • TOWN Ok'SOU ROLD AI~'PLtCATION FOR ELECTRICAL INSPECTION - REQUESTED 13Y_ Dat-e-:— IT( G !Company Name: -f_ __1_,`'1_ De slc� �.0`<�• • - _ •Name: _ - �- • -t- License No,: _i_4' .1 INC: _ . Address: v.n. - ( - �Q > Phone-No.:" E,3 I S -- R E[ _ . J.OBSITE INFORMATION: Cliidicates required information) • *Name:. - . Ce, ar NA - _ . •- . �" `,, , q *AcIdm ss. V ter}i� - ) e + . --m marl' a i"V . *Goss Street •,• A . *Phone No.: r .. _ Permit No.: NET _ Tax•Map District • 1000 action: 5j0 • BIock: 1 Lt+o • _ 3 3 ' *BRIEF DESCRIPTION OF WORK(Please Print Clearly) - Please Circle All That C \ Is job ready for inspection: • - YES I NO. Rough In Final *Do-you creed a Temp Certlfrcate: _ YES - - Temp Information(If neededi - - *Service Size: 7 Riese 3Phase 100 150 200 300 350 400 Other *New Service: Re-connect Underground Number of Meters Change of Service Overhead . Additional Information: PAYMENT DUE WITH APPLICATION • _ ,82=R•equest for inspection Form ' f �y , ; ; ::_-__,i,_?..i, a; 0..a.4q,- . ,,,,..71,:- \ -r."--":„,(\\----- '7" L.. . .1.----1442 _ ._---. 0- --s-- _ .. gs--,. ,: ;;.,---,:_- : -,-- TOWN OF SOUTHOLD PROPERTY- _RECORD CARD `�O l ' ;1�:7-1'Z- /0-0.'0 - g--6- / - it3 , '.1-R- td., -OWNER Miert �Lo.c148YL' 4. I STREET 3 v- -1 VILLAGE I DIST. I COUNTY TAX MAP NO. 11 1e..r � i.7 W E'-M r 11-e..r 1 Go_k „by-1iJ Q .. I Sat1 o i _ _ --- I sr I /041-0,e6 -1-,s3 _ . :I-4-..srmi l . A-4 1�`I ier rc. -, -/Q _ -- .c ?6D Re_ /47e/". olop,/ VTab'� \:Yp�° eS .4 `(L-2/7.-... LAND IMP. - TOTAL DATE REMARKS: rl /..(A-:' - '-,-- -- -- /e).c5-c>- --- . 61( Q--d / --.‘o C) -! - /542/9'7 -- -iia/q- L//759/ /vine,;=• r.'v h2►'l/2r=AAL ...__ .._ a 6,0-- --- -- - - �� 0 0, -- -- -e o (1-cc) ✓ Aler-el - 31a)163--:8P*-a 9.6,-bJ cidcil Tram -'60 fora: ia1 .... .i -l=-0- - - - K 2- f 2,-() , , .1 api/ as71pc/59- „ifiLiler fp r t(.1I&i ; r/c, . ._ / 6- ---- -_ - _- ' `=fid o---1.D. .. - _ �q S7-177i,Itr i - -51()(3 -- /-6-�- �' Baa . q � -,�Rg. - - - go ,yam �L ��. . „be,�! 0-s6-o90 -7000 . - 70(� G0,F__ p4 j ,////s—_ _ ,s . /iii. 4-70-0 - - ... , J ,5 ...„. 7 '1G „. . ...... a M Qa T.,_ - ---—1 ; -...--- COLOR • , .., ..;, ..- .--•,-.4,..i...,., _,,,,,,,,,,..\,......,. i... ••4.1q4 ..,•...L.,7 . , •....1„. r -•-• . -, ••• • •...i-,-. ...,,,-, ,,,,? •• - ,:,,,,, ,vyf. .....,„".4,2:,,,,:a•i- •-•' (7e J:,t,.\,,,F...-,'•--,.: :=,:,:--,.& 4:- %tt., .i s ___________,,t3 Nil,i.;•i .,,,t,;:,:r0V,,,...-- ;.',.'-4;:'--;:,,,,-;',. ..'".1!'-1'14.-i=WittiT digo...7_11,f,ii. . :,1.•....._ 1 t A.',21/ •..• •1. 1•P'.4-4'Z''','!AL•• ••_A'I'‘n)S'A• c• •Iv 1,--tAALW-A.- - 16 - g- 14.,' - ro• ,,,. ktit,ya•A.,' i, i....4rif Cti,-; it; tin 104/A.V.h.411.?...7* --- . ti -;-'41%70:4401,,Nit• fAli,tiV,PP:440'4144/04•1` ZNiVi r4giRtfielt.3.3- i'A' S'•,'''.1•11.,•,;;;,.,'`,'•'1111,4'I 'tiiit,, , '-'••7t 1.• '6,,,12/•,4,0;,,,,' .,,,,t: ,,ka1,3b. ki.k.:‘,IieR..,..:".,;•,...; 2t { v c- f.. ,i' "• /), ''''i,' • :,, ,.,4-.4.1. i •:•,-,4, :.' al ..k. ,,. .. • . . .._- 1...,-.-,:.: . VZ . '1. -1. "c- At V"j..$ 1/4 III.' 1 ' r • ,.. • _ril..q• . . ,, ., 1 . . .„..;,,., '.1-' :, , „. •' 2.:4;•%•';iit :•:' '• • ,..... _ 7.0 — -."1.,2 4,..• I ' iti'lll 14-4P' NIVI' ,0 1 ,., ,.,.„..., ,,,4,,p -.Am.! •,..1,•1 ,"—.7771., r:• ----1-•,---a-,-,-, .1 -,.a,lv...-1,,,; ( 'K I ti, • Ho „ '•44'i-,,,,,,httil.,•Ikli4i*/;Z----r ''17 A 11-±1.4 1 ''.-1-r•-' ..z.,‘„,:s, *.,`n•.:-• z- 2--,-ri TRIM ila:f.,,,if:'..,1•1111.41v..;•,..4-...pt.ALA!!:.f.4.:, .. 1.A.4 a7.1 ::".. I.g.4.d.,Lzi rt...— t-a ':Y ... .".$0 .1,t1t,`•••,. '-'4401:"4.1 Oi's 1". . , . . .t • „ , • . 'It''.., r.1.4' ey...Z"e'li`i:'''•'',;":"....".-: , ,i ........: .:..- "`fr. , 1 I4-.4.4---,...ri"....",35.4,.Fini.••••,,...,.:,,,•:.--....7 -4.--"."4-4—•"4"---- --"*.'-` • '7.s--, * • . , .-,i,, Air •.-,, ,.... -----1"-'- 4 • • ‘A.C.• e.•v.:. .,„••• --,...A........ .• ,,,,t..,,,, 1,,,'' 1 • , J. . r , I;1•• , - 4 -'1:-.-z '.,ili,:di L-4: I, . -.(i i : '2' • h}lil .1"F!"'"'-t‘7Till'All'l'''04,111111n3 ' HMV 1 I il AM 111111110E. - t : t ,,,'';,--,L,7,?:•-:•••••`÷-.74- -'rt' - •'•' ' 11. • I 7-r) -....,9r• •••-•••••••=• 7„, ,,, - , „....-____L,--- ,,..-- . ,......, ) taw ingo, ... .. ;,•• .. '="•-5:,--7•:----4 4•47.,:.,-,, -- -:=•---a., .• .,-..* ,..... „_,- — ,...,-1 •':• - ---- ,.,-aft` . tNI-... .4,A-7,•;',-:.:- . ..t,:4•17,`;-••-7--r...,Z-T:',.•."-- • _ m iiri,tr. . - • . : - - "."-i":"1 ' "'-,"...; .: -*7'" '• ''' '-"-::' " -'-' ' , . . . 7' '•• T..-. : ''-' ;" %lac 1.'..,.;--T; t,..',„..• -•• . - . „t...--•••."`.7-4.7. '''''” —' ' " . . . . , . . 80.-1-33 3/05 .. - 1--- 1st 2nd I -I I-1-1 P C Fin. B. Bath A \ Dinette , \ N....-- • _ (3 ,is 2;32,04- 7c36 z 75 2: . _L.F.....-'Tdg. Foundation . : 31 5- ULL COMBO icr7 :- Basement PARTIAL Floors Ock.A.3 oick --- Kit. ./ r-- t SLAB. i - L.R. ---Fta-te4/84-1944-, I ste ..... _ - Interior Finish'56(Lf- - g-(lel 1+500 Ext. Walls sExte„ri1sion cDeb er" - Heat IckW&4 I 4 --.>\ 17 y, I 'ti, 2--• 3 Fire Place '`(-eita, Extension D.R. 7 . BR. V 3 e.q TO 2..0'2— . l Patio , Woodstove Co Y..2c1 = 17 Li- afn Baths Dormer 6, y 2-0 = Ca-t) _ Porch . Fam. Rm. IL ---- Dock %7-5- 'R t Deck \8 Ifi , s =, 2-4- A.C. Garage z 2 x 2 8, 6 t(9 ( 77 , O.B. ci 3ery , r . , . Pool . -- , 11; '' —1.-r" .7*. — --1115111-€ 0 al 4 7—. in//)11,5 70to wer.Aar ...;•—""Th IR sZe .=!=leIsim ,.....6......' . • SCDHS Ref. # RIO-03-0077. - 4 1 SC1 6 or ctf i 4% \o 0�3� / 4 or P,24 ss • fl � •7w C. '-576o `F aor c 0196. • i Q' tih i /0:6: O rad ase. / V O A<„,... -c• `2 Q �•, 620 ! O0 23 LOT . , zT Ci9. �f� 45:5'• • g i \. 1 -t ,0)4 " , r\V CLQ �'��� / ` \?`'��1 `;N O `0 I 4 xi' '"', ', a"•e m \0�c .0'LOT w J c 17S 5 wexter Oto CI �1 pto ,.,. Np ,noa el V, �� LOT� 42 ��z�'; 1 , �: p.� 71' i'\ •.�� - - - ,,tia.60' - _._ --___ __-, - - O.P el i 9 77°32'00, W' (Pub mDa �� S. LOT (9 k, / s / ,' • SURVEY OF �' LOTS 39thru 42 inclusive ` BLOCK Ck- "REYDON SHORES" Q FILED JUL Y 2,1931, FILE NO. 631 ` AT SOUTHOLD Q , TO WN.OF SOUTHOLD Q SUFFoOL a COUNTY,, NY. 0 or 33 - . Scale: 7"- 40' Dec. 27, 2002 The locations o/ wells and cesspools MAY I, 2003 ( prop. addition 1 shown hereon are from field observations JUNE 6, 2005 (FINAL) iand or from data obtained from others. I am fbmlllar w1/h the STANDARDS FOR APPROVAL AND CONSTRUCTION OF SUBSURFACE SEWAGE DISPOSAL SYSTEMS FOR SINGLE FAMILY RESIDENCES and will abide by the conditions set forth therein and on the permit to construct. I ���, � ��NGS �.. EL EVA TIONS ARE REFERENCED TO THE FIVE EASTERN •,. TOWNS TOPOGRAPHIC MAPS �, �a411:671., 4 4NY ALTERATION OR ADDITION TO THIS SURVEY IS A VIOLATION ` OF SECTION 7209 OF THE NEW YORK STATE EDUCATION LAW ! EXCEPT AS PER SECTION 7209 - SUBDIVISION 2. ALL CERTIFICATIONS -= , HEREON ARE VALID FOR. THIS MAP AND COPIES THEREOF ONLY IF * ,l' SAID MAP OR COPIES BEAR THE IMPRESSED SEAL OF THE SURVEYOR l NO : ''8 19- WHOSE SIGNATURE APPEARS HEREON. ��,r y 1a P CONIC S �. YORS, re ADDITIONALLY TO COMPLY WITH SAID LAW TERM ALTERED BY ' (63/1 765 - 5020 FAX (•'" 1797 MUST BE USED BY ANY AND ALL SURVEYORS UTILIZING A COPY P. 0, BOX 909 O•F ANOTHER SURVEYOR'S MAP. TERMS SUCH ' INSPECTED " AND 1230 TRA VELER STREET BROUGHT - TO - DA TE ' ARE NOT IN COMPLIANCE WITH THEL,A W. SOUTHOLD, N. Y. 1197/ 02-348. „ 0-Re_ APPR VED AS NOTED DATE:2 #.._.. ..r. •, l, RETAIN STORM WATER RUNOFF FEE: 2BY: PURSUANT TO CHAPTER 236 _ __4���_,./,/. NOTIFY BUILDING DEPAR T AT OF THE TOWN CODE. 765-1802 8 AM TO 4 PM FOR THE FOLLOWING INSPECTIONS: 1. FOUNDATION - TWO REQUIRED FOR POURED CONCRETE 2. ROUGH - FRAMING & PLUMBING 3. INSULATION 4. FINAL - CONSTRUCT ON MUST BE COMPLETE FOR C.O. ALL CONSTRUCTION; SHA!L MEET THE ELECTRICAL REQUIREMENTS OF THE CODES OF NEW INSPECTION REQUIRED YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS. COMPLY WITH ALL CODES-OF NEW YORK STATE & TOWN CODES AS REQUIRED AND CONDITIONS OF S Ot&i81{ US-TEES OCCUPANCY OR USE IS UNLAWFUL WITHOUT CERTIFICATE OF OCCUPANCY GENERAc® Th/2%/22 kGUARDIAN® SERIES Residential Standby Generators Air-Cooled Gas Engine 1 of 5 INCLUDES: Standby Power Rating • True Power' Electrical Technology Models 006459-0, 006461-0, 006462-0 (Steel-Bisque) -16 kW 60 Hz • Two Line LCD Multilingual Digital Model 006721-0 (Aluminum- Gray)-16 kW 60 Hz Evolution'' Controller (English/Spanish/ Models 006729-0, 006730-0 (Stool-Bisque) -20 kW 60 H7 French/Portuguese) Models 006551-0. 006552-0 (Aluminum-Gray) -22 kW 60 Hz • Two Transfer Switch Options Available' 100 Amp Pre-Wired Switch or re 200 Amp Smart Switch. See Page 4 for Details.. • Electronic Governor � ij f • External Main Circuit Breaker, System Status & - - ,•... Maintenance Interval LED Indicators Y a . u, " • • GFCI Duplex Outlet GENERAC`• Sound Attenuated Enclosure• 4utrAaa Seiids'�3 • Flexible Fuel Line Connector ; : , • Composite Mounting Pad• Natural Gas or LP Gas Operation �� Bs • 5 Year Limited Warranty cLISTED QUIET TEST • Capability to be installed within 18" (457 mm) Note CUL certification only applies to unbundled units and units packaged with pre-wired switches of a building* Units packaged with the Smart Switch are UL certified in the USA only *Only if located away from doors,windows and fresh air intakes,and unless otherwise directed by local codes. FEATURES O INNOVATIVE DESIGN&PROTOTYPE TESTING are key components O SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION. of GENERAC'S success in "IMPROVING POWER BY DESIGN"But it This state-of-the-art power maximizing regulation system is standard on doesn't stop there Total commitment to component testing,reliability all Generac models It provides optimized FAST RESPONSE to changing testing,environmental testing,destruction and life testing,plus testing load conditions and MAXIMUM MOTOR STARTING CAPABILITY by to applicable CSA,NEMA,EGSA,and other standards,allows you to electronically torque-matching the surge loads to the engine Digital choose GENERAC POWER SYSTEMS with the confidence that these voltage regulation at±1% systems will provide superior performance. O TRUE POWER"' ELECTRICAL TECHNOLOGY: Superior harmonics 0 SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer and sine wave form produce less than 5% Total Harmonic Distortion for network provides parts and service know-how for the entire unit,from the utility quality power.This allows confident operation of sensitive electronic engine to the smallest electronic component. equipment and micro-chip based appliances,such as variable speed HVAC systems. 0 GENERAC TRANSFER SWITCHES. Long life and reliability are O TEST CRITERIA: synonymous with GENERAC POWER SYSTEMS. One reason for this ./ PROTOTYPE TESTED s NEMA MG1-22 EVALUATION confidence is that the GENERAC product line includes its own transfer • SYSTEM TORSIONAL TESTED MOTOR STARTING ABILITY systems and controls for total system compatibility GENERAC® SO ... 1V90011: "v.. ..w>... 2008 GENERAC® N `V 16/20/22 kW features and benefits 0 coEngine •Generac(OHVI)design Maximizes engine"breathing"for increased fuel efficiency Plateau honed cylinder walls and plasma moly rings helps the engine run cooler,reducing oil consumption resulting in longer engine life • Quiet Test'" Greatly reduces sound output and fuel consumption during bi-weekly exercise,compared to other brands. •"Spiny-lok"cast iron cylinder walls Rigid construction and added durability provide long engine life 2 of 5 •Electronic ignition/spark advance These features combine to assure smooth,quick starting every time. •Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance,less maintenance and longer engine life Now featuring up to a 2 year/200 hour oil change interval. •Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil •High temperature shutdown Prevents damage due to overheating Generator •Revolving field Allows for a smaller,light weight unit that operates 25%more efficiently than a revolving armature generator •Skewed stator Produces a smcoth output waveform for compatibility with electronic equipment •Displaced phase excitation Maximizes motor starting capability •Automatic voltage regulation Regulates the output voltage to±1%prevents damaging voltage spikes •UL 2200 listed For your safety Transfer Switch •Fully automatic Transfers your vital electrical loads to the energized source of power •Pre-wired,color-coded conduits Ensures the easiest,trouble-free installation (Pre-wired switches only) •DPM Technology Digital Power Management Technology allows for the smart control of two air conditioners without any additional (Smart Switch only) items •Remote mounting Mounts near your existing distribution panel for simple,low-cost installation. Evolution— Contrcis •Auto/Manual/Off illuminated buttons Selects the operating mode and provides easy,at-a-glance status indication in any condition •Two-line LCD multilingual display Provides homeowners easily visible logs of history,maintenance and events up to 50 occurrences •Sealed,raised buttons Smooth,weather-resistant user interface for programming and operations •Utility voltage sensing Constantly monitors utility voltage,setpoints 60%dropout,80%pick-up,of standard voltage. •Generator voltage sensing Constantly monitors generator voltage to ensure the cleanest power delivered to the home. •Utility interrupt delay Prevents nuisance start-ups of the engine,adjustable 2-1500 seconds from the factory default setting of 5 seconds by a qualified dealer •Engine warm-up Ensures engine is ready to assume the load,setpoint approximately 5 seconds •Engine cool-down Allows engine to cool prior to shutdown,setpoint approximately 1 minute •Programmable exerciser Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every other week Also offers a selectable setting for weekly or monthly operation providing flexibility and potentially lower fuel costs to the owner. •Smart battery charger Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. •Electronic governor Maintains constant 60 Hz frequency a�..w.w.. _�o...�......�.w�.v....�m��,.�� ..,.��ti._.�.. .n_r.�.m.m._... ��n.�.�.�.._�_.�.�...��..�.. ti�� �.�rom• m.�,�.�. Unit •SAE weather protective enclosure Sound attenuated enclosure ensures quiet operation and protection against mother nature,withstanding winds up to 150 mph.Hinged key locking roof panel for security. Lift-out front for easy access to all routine maintenance items Electrostatically applied textured epoxy paint for added durability •Enclosed critical grade muffler Quiet,critical grade muffler is mounted inside the unit to prevent injuries •Small,compact,attractive Makes for an easy,eye appealing installation,as close as 18"away from a building.* Installation System •1 ft(305 mm)flexible fuel line connector Absorbs any generator vibration when connected to rigid pipe •Composite mounting pad Eliminates the need to pour a concrete pad unless required by local municipalities GENERAC® „ ,n CV 16/20/22 kW specifications o Generator • N 006459-0,006461-0,006462- 006729-0,006730-0, 006551-0,006552-0 Model 0,006721-0(16 kW) (20 kW) (22 kW) 'Rated Maximum Continuous PoowerCapacity[Ll] ._.-. .... :.-...._.,-.,. 16 000 Watts' 20,000 Wails* , ._. `- 22,006 Wad' .,-._.. w ' Rated Maximum Continuous Power Capacity(NG) 16,000 Watts* 18,000 Watts* 19,500 Watts* 'iRated Voltage° ,. , ' , °ro. ,.,. .,, :° ,. . , xp. 240. 240 240 Rated Maximum Continuous Load Current-240 Volts(LP/NG) 66 6/66 6 83.3/75 91.6/81 3 Total tlartnislic Distarhun WmLess than 5% ",, Less than 5% �, Less lIen 5%„ _ 3 of 5 Main Line Circuit Breaker 65 Amp 90 Amp 100 Amp Phase _ .4. 1 ;:1 1 Number of Rotor Poles , 2 2 mm µ ,..", 2 .BO Hz --``64.12 ,a 60 Hz ;Rated AC Frequency.m_..- ....�...� - ..,. ...._...... _�..�.�n._�°-...w_._._,_ ��..,W _.�,._.�,�..:<�,.. .�.. . __,.�..._w.....-._.._..a _�:,. Power Factor 1 0 1 0 1 0 Battery;Re uirement pit included) ° = _ ° t Group 288,12 Volts and 525 CCA Minimum .�.. ._._. Unit Weight(lb/kg) 513/232 7(Steel), 516/234.1 526/238.6 448/203 2(Aluminum) Dimensions(L x.W x H)in/nlm .._<, 4"^` M __._ 6 x 25 x 2911218 x Fi36 x 732 Sound output in dB(A)at 23 ft(7m)with generator operating at normal load** 66 66 67 r Sound output indt3(A}at 231' with gepekatorin QuistTest's.low-spsei rte,^` 60` -- 0,— *''` Y W W . ,.exercise made'* .'frir); .,, Exercise duration 5 min 5 min 5 min Engine fipi of Engine___-;_,_ ";,.__ __.,.. _ ,r, ,,__..: J@, IACOHVIV-NVIN_,__ _. ,, GENERALOHVIV$WI)l__ GENERALOHV1V-TWIN Number of Cylinders _ 2 2 2 l3isptacement ` _._992'cc . 999'cc' ;999r Cylinder Block Aluminum w/Cast Iron Sleeve Valve Arrangemrigt7,,:;f--„;,,,, g;; Overhead Valve ? :Overhead Valve Overhead Valve° _• , Ignition System Solid-state w/Magneto . Solid-state w/Magneto Solid-state w/Magneto Govemoi System �..._ Etectronic y _ Elect€onic Electronic <L '° 1 Compression Ratio 9 51 9.51 9 51 Starter _ 12 Vdc Y= 11)Alt°- Ps 12 Vdc° i Oil Capacity Including Filter Approx 1 9 01/1.8 L Approx 1 9 qV1 8 L Approx.1 9 qt/1 8 L 9.11q6116 core _._-. _.._ry _< .. ._. 3,6QtI...,.- 'm -.3,600 •_ '3,60© . ' . Fuel Consumption _ _ Natural Gas ft,/hr(m3/hr) - " ,1/2 Load 193(5 47) 205(5 8) 184(5 21) Full Load 312(8.83) 308(8 72) 281 (7.96) Liquid Propane f13/hr(gal/hr)[I/hr] 1/2 Load 72.4(1.99)[7.53] 75.6(2 08)[7 87] 83(216)[8.16] Full Load 130(3 57)[13.53] 140(3 85)[14 57] 127(3 68)[13 99] Note:Fuel pipe matt be sized tor,fult load. Required fuel prssstire to generator fuel Inlet at all load ranges-3,5-7",water column(7-13 mini mercury)for natural gas,1642"water column i9-22 mm mercury)tot l.P gas For Btu centent,T mult)plyr it3 tr x.,$5,00(LP)or uta/hr x 1 Opo(NG).,Eor Megaloule content,multiply m?Anr x 93.15(I?)et m?/hr x 87,26{NG),,_•„ .._ _. .' Controls 2-Line Plain Text tvfuitgin., LCD Oisp)ay<,,, ,, <.---r-,,„ R' _ Y_ ', , .. q . Simple user interface ase of()Walk/n'm.`` _ ,, Mode Buttons Auto Automatic Start on Utility failure 7 day exerciser. Manual Siam withrstarter conical,unit sta s dolt iltsli !s'transfer 10 Ioa takes dee; Off Stops unit Power is removed Control and charger still operate m. Ready toRunVMa(ntenance Messages �k: ' ' S c Engine Run Hours Indication Standard Rra rarrtniable sta dal between 2-1500 seconds °-' °' _ °""--- " -, ''',-'''''''-''Start lard ro mable ti dealerorrl - m ° Utility Voltage Loss/Retum to Utility Adjustable(Brownout Setting) From 140-171 V/190-216 V Future Set Ca able Exerelser/Exercise Set Error Warnin '• '- k Standard'a '- 7--°7�y--7- - Run/Alarm/Maintenance Logs 50 Events Each I•Engine Start,Sequence w` °_. „ (41,0spciO4m16 sec or 7,rarest(90 see maxi murit'duration), Starter Lock-outStarter cannot re-engage until 5 sec after engine has stopped Smart Battery Charge_ ... ._... . .._..... W ._ standard Charger Fault/Missing AC Warning Standard Low Bait any/Satiety Pooh emjotechori d Battery.Condit(oo-indicatian L.1.,,,,,..,„ -;,, , __ ._`_ -,.,,„ o Standard .°, ;. "' 1 Automatic Voltage Regulation with Over and Under Voltage Protection Standard tinder-Frequency/OverIeadlStepper•fl ercurrent Pretection . ,, Standard . Safety Fused/Fuse Problem Protection Standard �.. are(, ed ,,.____",7 .,'7:777-- . .-,.. `, . .._ . .__ .,_.., Standard. w _._,. _,,,,.., Qutornalic Low:O11 PtossurelHi b Oil Tem uaturoSfrutdowii .. Overcrank/Overspeed(@ 72 Hz)/rpm Sense Loss Shutdown Standard �i .6ngineTemperatureShutdown , .,.,,,- _ ...,�,'7 °...9..°[..v ,, •'- ,_ r _Standid .. 1 +'.' ..,,.,._ ,.- <,,. .<,._.............. h Internal Fault/Incorrect Wring Protection Standard Common External Fault Ca abili tl _ _ _ °'Standard:- e _,"°"..� '' • Field Upgradable Firmware Standard **Sound levels are taken from the front of the generator Sound levels taken from other sides of the generator may be higher depending on instailabon parameters Rating definitions-Standby Applicable for supplying emergency power for the duration o1 the utility power outage.No overload capability is evadable for this rating (All ratings in accordance with 655514,1303046 and 01N6271) *Mawmum wattage and current are subject to and limited by such factors as fuel Btu/megajoule content, ambient temperature,altitude,engine power and condition,etc Maximum power decreases about 3 5 percent for each 1,000 feet(304 8 meters)above sea level,and also will decrease about 1 percent for each 6°C(10°F)above 16°C(60°F) . GENERAC® - ` 16/20/22 kW switch options 0 CV Pre-wired Features Model (.0006461-0(16 kW) available on Steel 16 kW models only11.1.40;0014.1...,w_. _. __ _...,m,_. m ....... • Electrically operated,mechanically-held contacts for fast,positive Current Rating(Amps)_ 100 connections. ,Voltage R ttng_U080 .-,. . - .- -°_..µ' .;_ .y2o/2 ,t0 , Utility Voltage Monitor(Fixed)* 4 of 5 • Rated for all classes of load,100%equipment rated,both inductive and -Pick-up 80% resistive. -Dropout 60% ;Return to tltiltt ,n _ , approx.15.. ec, • 2 pole,250 VAC contactors. Exercise weekly for 12 minutes* Standard • 30 millisecond transfer time. :UL Listed,. , .-r . ,, =P ... Standard::; , Total of Pre-wired Circuits 16 • Dual coil design. No.15 A 120 V 5 • Main contacts are silver plated or silver alloyto resist welding and sticking, No 20 A 2140 V 5 9 No 20 A 240 V 1 • NEMA 1 (indoor rated)enclosure is standard on the pre-wired switch. No 30 A 240 V No,40 A 240 V 1 • Pre-wired 30 foot(9.1 meter)whip to connect to the provided 5 foot pre- No.50 A 240 V 1 ' 'QiriuiiBreakerProtected ' '° wired whip and external connection box. , -, ,,,. t € ,,Avaliable RMS Symrnetricafa. , ,°r . • Pre-wired 2 foot(0,61 meter)whip,color coded to connect into the x .Fault Current @250 Volts . e , n _.--10000 :,W ;_ej existing electrical panel *Function of Evolution Controller I Dimensions Mechanical Dimensions ' Height Width .,[7j-1 Depth H1 H2 W1 W2 in 235 264 8.3 126 63 Hz ' H, mm 597 671.7 211 320.7 159 6 Wire Ranges ' Conductor Lug Neutral Lug Ground Lug Ali ' 2/0-#14 2/0-#14 - 2/0-#14 wi--I W2 Smart Switch Features Model 006462-0(16 kW)/006729-0(20 kW)/006552-0,(22 kW) • Includes Digital Power Management Technology standard(DPM). No.,cfPoles„;µ f'.„,',';''' ' ' ° ` `, ,,g1 ”" Current Rating(Amps) 200 • Intelligently manages two air conditioner loads with no additional ?'vo)tageRating(VAC) ;77,37,-,R7:7 .,i 2t312g07l0 °�; hardware. I Utility Voltage Monitor(Fixed)" ._._ • Up to four more large(120/240 VAC)loads can be managed when -Pick-up 80% used in conjunction with Power Management Modules(PMM**). -Dropout so°k [Return toUtiltity.. ',''.;.° °"' _?Pproxrl3sec..:; "`' .• ,, :1 • Electrically operated,mechanically-held contacts for fast,clean Exercise weekly for 12 minutes* Y Standard ilLLtsted�, Standard ___ , .w-- 1 connections. _ � ........,�_.. .�3�:�.. ... ��.:::..�... Enclosure Type NEMA/UL 3R • Rated for all classes of load,100%equipment rated,both inductive Lwithstand Rating.l s}'T:.. —1, -kbDa„ and resistive. Lug Range 250 MCM-#6 • 2 pole,250 VAC contactors. *Function of Evolution Controller • Service equipment rated,dual coil design. • Rated for both aluminum and copper conductors. • NEMA/UL 3R aluminum outdoor enclosure. --W' • Main contacts are silver plated or silver alloy to resist welding and sticking p.,y **Note:PMM starter kit is required prior to using the modules. t HI Dimensions 200 Amps 120/240,10 , Open Transition Service Rated Height Width Depth - H1 H2 W1 W2 in 27 24 30 0 11.4- -13.5 , 7.09 • mm 692.0 762.4 289.0 343.0 180.0 DEPTH I Wz-a r • . GENERAC® 16/20/22 kW available accessories "' 0 N Model#` ' Product ° °• , Description ;Generac's Mobile Link allows you to check the status of your generator from anywhere that youu have r 006463-1 Mobile Linktm access to an Internet connection from a PC or with any smart device.You will even be notified when a change in the generator's status occurs via e-mail or text message. 005819 0 26R Wet Cell Battery i Every standby generator requires a battery to start the system.Generac offers the recommended 26R wet cell battery for use with all air-cooled standby product(excluding PowerPact®). j 5 of 5 If the temperature regularly falls below 32°F(0°C),a cold weather kit is required to maintain optimal I 006212-0 1 Cold Weather Kit `battery and oil temperatures.Kit consists of a battery warmer and oil filter heater with built-in i thermostats. Auxiliary Transfer Switch Contact 1 The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical 005621-0 I Kit j load you may not need.Not compatible with 50 amp pre-wired switches. 005839-0-Bisque Fascia Base Wrap Kit* 'The fascia base wrap snaps together around the bottom of the new air cooled generators.This offers •a sleek,contoured appearance as well as offering protection from rodents and insects by covering the . 005666-0-Gray 1 (Standard on 22 kW) =lifting holes located in the base. 005703-0-Bisque I If tile generator enclosure is scratched or damaged,it is important to touch-up the paint to protect 005704-0-Gray Paint Kit* from future corrosion.The paint kit includes the necessary paint to properly maintain or touch-up a generator enclosure. j 006484-0-16 kW 1 Generac's scheduled maintenance kits provide all the hardware necessary to perform complete Scheduled Maintenance Kit 006485-0-20&22 kW i i routine maintenance on a Generac automatic standby generator ( Completely wireless and battery powered,Generac's wireless remote monitor provides you with 006664-0 "Wireless Remote Monitor ff instant status information without ever leaving the house.Not compatible with CorePower or EcoGen .I systems. s I The PMM Starter Kit consists of a 24 VAC,field installed transformer that enables the use of the 24 j 006199-0 1 PMM Starter Kit VAC Power Management Modules(PMM5)and one PMM.The standard controller(without starter kit) j `can control two HVAC loads with no additional hardware.Not compatible with pre-wired switches. Power Management Module(50 [Power Management Modules are used in conjunction with the Smart Switch to increase its er pow 7-1 006186-0 Amps) t management capabilities.It gives the Smart Switch additional power management flexibility not found ._,. ^in any other transfer switch.Not compatible with pm-wired switches.Note PMM Starter Kit required. *Note:Bisque kits are used in conjunction with steel enclosures Gray kits are used in conjunction with aluminum enclosures. dimensions & UPCs Dimensions shown are approximate Refer to installation manual for exact dimensions DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES 637 6 mm [25 1 In] [2189m] r /r.�. — -�_ _ ,�„ - � n .�,*•'�a,,- .�;:.,.<� Model I UPC ' P 006459-0 696471064599 i 0064610 696471064612 rw,..-tea.-s....-.»- d - M. , IV- V:Q ` 006721-0 696471067217 7319mm _ -8 '- " . [28 a m] { , j ... 006729-0 696471067293 f 006730-0 696471067309 tea -_""=` wt 006551-0 696471065510 tr Vi //�/�e/���/�� 006552-0 696471065527 A7 // Ar4 '%//%%//�//%///��/%///// /�/� 006462-0 696471064629 642 mm [25 3 in] 1226 mm [48 3 in] LEFT SIDE VIEW FRONT VIEW GENERAC Generac Power Systems,Inc. • S45 W29290 HWY.59, Waukesha,WI 53189 • generac.com "'u" " ©2014 Generac Power Systems,Inc. All rights reserved.All specifications are subject to change without notice. Bulletin 0K8458-C Pnnted in U S A 06/18/14