Loading...
HomeMy WebLinkAbout39228-Z 1',�o�sUIPOt�c'e Town of Southold 4/11/2016 / P.O.Box 1179 53095 Main Rd ,"140 se Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 38218 Date: 4/11/2016 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 2230 Soundview Ave,Mattituck SCTM#: 473889 Sec/Block/Lot: 100.-2-3.2 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 9/11/2014 pursuant to which Building Permit No. 39228 dated 9/30/2014 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: ROOF MOUNTED SOLAR PANELS TO AN EXISTING ONE FAMILY DWELLING AS APPLIED FOR The certificate is issued to Krupski,Eugene&Krupski,Maryann of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 39228 03-22-2016 PLUMBERS CERTIFICATION DATED Authorized Signature ' � TOWN OF SOUTHOLD ,,,f' UFFo1K4 BUILDING DEPARTMENT i o - TOWN CLERK'S OFFICE o SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 39228 Date: 9/30/2014 Permission is hereby granted to: Krupski, Eugene & Krupski, Maryann 2230 Soundview Ave Mattituck, NY 11952 To: install a roof mounted electric Solar Panel system as applied for At premises located at: 2230 Soundview Ave, Mattituck SCTM # 473889 Sec/Block/Lot# 100.-2-3.2 Pursuant to application dated 9/11/2014 and approved by the Building Inspector. To expire on 3/31/2016. Fees: SOLAR PANELS $50.00 CO -ALTERATION TO DWELLING $50.00 ELECTRIC $100.00 Total: $200.00 Building Inspector Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings,property lines, streets,and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal (S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead. 5. Commercial building, industrial building,multiple residences and similar buildings and installations,a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings(prior to April 9, 1957) non-conforming uses,or buildings and "pre-existing" land uses: 1. Accurate survey of property showing all property lines, streets,building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00,Alterations to dwelling$50.00, Swimming pool $50.00,Accessory building$50.00,Additions to accessory building$50.00, Businesses$50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy -$.25 4. Updated Certificate of Occupancy - $50 00 5. Temporary Certificate of Occupancy- Residential $15.00, Commercial $15.00 Date. l 3,1 L( New Construction: Old or Pre-existing Building: (check one) Location of Property: � 2 1D 5 e OL.C.. V iA1-3(X �U House No. Street Hamlet Owner or Owners of Property: gene -Krug Suffolk County Tax Map No 1000, Section Block Lot Subdivision Filed Map. Lot: Permit No. 30,aS Date of Permit. Applicant: Health Dept. Approval: Underwriters Approval: Planning Board Approval: Request for: Temporary Certificate Final Certificate: (check one) Fee Submitted: $ 50 'tit) Applicant Signature II,,,�o`c SO(j j Town Hall Annex �i Telephone(631)765-1802 54375 Main Road 111111 * Z Fax(631)765-9502 P.O.Box 1179 G A�� Southold,NY 11971-0959 :`�Ol� �O',I, roger.richert(c�town.southold.ny.us = coup(,�,,.i' BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION Issued To: Krupski Address: 2230 Soundview Avenue City: Mattituck St: New York Zip: 11952 Building Permit#: 39228 Section 100 Block. 2 Lot: 3.2 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: Solar City License No: 51331-ME SITE DETAILS Office Use Only Residential X Indoor X Basement X Service Only Commerical Outdoor X 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures HID Fixtures Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel NC Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel NC Blower Range Recpt Fluorescent Fixture Pumps Transformer Appliances Dryer Recpt Emergency Fixtures Time Clocks Disconnect Switches Twist Lock Exit Fixtures TVSS Other Equipment: 18.5 KW Roof Mounted Photovoltaic System to Include 74 - YINGLI 250W Panels, 2-PV1 4.2 Inverters Notes: " r..Inspector Signature: Date: March 22, 2016 Electrical 81 Compliance Form.xls - - cf, \ :* *1 (14k11 TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLUMBING [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ...LELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] CAULKING REMARKS: - 71/ fj5iWif DATE -3/1'0 6 INSPECTOR f t Version#55.3 • SolarCity D EICEOVE Project/Job# 119179 — 1 APR - 8 2016 RE: Installation Approval Letter Project: Krupski Residence BUILDING DEPT. 2230 Soundview Ave TOWN OF SOUTHOLD Mattituck, NY 11952 Date of Review 3/31/2016 Permit# 39228 Date of Install 3/12/2016 AHJ Southold Town SC Office Long Island To Whom It May Concern, On the above referenced project,the roof structural framing has been reviewed for additional loading due to the installation of the solar PV addition to the roof.The structural review,including the plans and calculations only apply to the section of roof that is directly supporting the solar PV system and its supporting elements. The capacity of the structural roof framing directly supporting the additional gravity loading due to the solar panel supports and modules had been reviewed and determined to be in accordance with the requirements of the 2010 Residential Code of NY State. I certify that the work has been completed in accordance of the provisions of the approved permits of the applicable code. Should you have any further questions or requirements pertaining to this project, please do not hesitate to contact me. of NEIN 1-- �/ � �gRIO/y c y°9,4 Digital 'signed/bySushd �� ECLI PSE * �� y *,_ Location:421 W-Riversld"e, ENGINEERING Inc.,P.C, ,Mre� STE 421,Spokane,IvvA r,5 Contact Info:5 9-921=7731 � �,1� _� Date.2016 04 001-- Eclipse Engineering,as a third party, 2J, 12:19 39-07'00' has provided a structural-only review of e, 095379 <," the enclosed project. A9°FESSI001/4\. 3055 Clearview Way San Mateo,CA 94402 r(650)638-1028 (888)SOL-CITY r(650)638-1029 solarcity.com ALL'„14'4? .+"F_r`'I 1 ..1'' •Ll,Ill 4.,., .1151 =';'O tip 1-i"; r. 11t .,.i rl ' C: ':nr, !Ir ` '7f1 I11-r - 4111 IL..i LL 11'4 u MDIII t.l. 'la Ih 1! - "I' 'III' • I 'h C_ r3'I'• .14 I r ,rt_ '1' r - I Cr '+1lc''FI' - i A 7.3.�r TI FCS ' ,- 'r1 +ill 1� i ':t.r :.t-r lr P.••I1•Cp, ,N: "f_f'_Jlr ,`[ v.. .V.,t'v.L ”111 r '1 r.fi Cr r.,i n t ' y! i.' �I'IM rn,n-.l nn I,11-r • _ -I. -' - 'I _ __ 15r M , 15' R_n' 1ri l r t n rrr"!n,'r,.e .n,f•.'I , ',r,,.., „ I, r n_t r'- n'._.r. r...at tea.,_ � rr v�..,,.,r•a.r-v.• ,.,..,_r'o. lI,I oT ,.i,tr ter. nc.< FIELD B SPECirIQN REPORT DATE COIVIlV ENTS ' gi v FOUNDATION(1ST) . - 1 5 FOUNDATION(2ND) . . 63 . - , r ..• ., . � O • . . . 4 • ROUGH FRAMING& d y PLUMBING . • c t4 INSULATION PER N.Y. H STATE ENERGY CODE • ' • . . .-r FINAL . . - . • . ADDITIONAL'Ct�1VIlYIENTS'w"'�*' x'' , • • 10-'. ' - , OLCA (.11,\. ttit:1) _ ,4---47-ii 0,0 6:to • ' . . ili2011A- - 1 i ri.4 _ •0 //, : (IL._ 1 ..132.0 iticte vi___72.- . 1. . . . cx)2 . . . . . . . . . . . . . . . .. .. • c.,,k) . . . , . .„ . ...I ' . ......."N • . ... . . , .. . . . g M .. . . F ,. - .. . . .. . . . . • . . . .. . . . . .. , `.. , .,N OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST JILDING DEPARTMENT Do you have or need the following,before af,plying? 1'+OWN HALL Board of Health SOUTHOLD,NY 11971 4 sets of Building Plans TEL: (631) 765-1802 Planning Board approval FAX: (631) 765-9502 Survey SoutholdTown.NorthFork.net PERMIT NO. a'>g Check Septic Form N.Y.S.D.E.C. Trustees C.O.Application / Flood Permit Examined ?'M ,20 ✓ Single&Separate 6666 Storm-Water Assessment Form Contact: Approved ,20 / G/ Mail to: Disapproved a/c Phone: Expiration 3 ,20 /12 Bui ding Inspector APPLICATION FOR BUILDING PERMIT Date , 20 111 INSTRUCTIONS • a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans, accurate plot plan to scale. Fee according to schedule. b. Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize, in writing,the extension of the permit for an addition six months. Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York, and other applicable Laws, Ordinances or Regulations,for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances, building code, housing code, and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. OCCUPANCY OR _� r ti s • a. ( ignatu of applicant or name, if a corporation) JSE a UNLAWFUL W 2 THnI T CFRTIFICATE o --N4-0 S u* C (Mailing address of applicant) or: Di5 Nr iNtecup,-) State whether applicant is owner, lessee, agent, architect, engineer, general contrAfhr";�d3e,o sic an,Itilumber or builder ELECTRICAL C'on-Mx[_517n ./mac n—f r.er-Tprw REQUIREDATE P, c o $,j1‘,)--4 tro FEE ADL ,� Name of owner of premises _I - V� Sal NOTIFY BUILDING DCP, R;,��� �l (As on the tax roll or la tidogd)8 AM TO 4 PM FOR Tt�,= If applicant is a corporation, signature of duly authorized officer ' ' ry•INC 'r' 1 r OUNU,\I iON - i ,^; c 1n FOR POURED CONCR 1 E (Name and title of co orate officer) 2 ROUGH-FRAMING,PLUM3ING, Builders License No. SDS7[y STRAPPING, ELECTRICAL&CAULKING Plumbers License No. �l 3 INSULATION `'``"' 4. FINAL CONSTRUCTION&ELECTRICAL Electricians License No. 57 1—/I-LE 1;,> ,- r•r. Other Trade's License No. MUST BE COMPLETE FOR C 0 s'- ;'1"'ALj CONSTRUCTION SHALL MEET THE g�0 , .Y•'A�; k•,�QUIREMENTS OF THE CODES OF NEW 1. Location of land on which proposed work will be done:' ;< ` r;+<<`t,,�,:YORK STATE NOT , / �(� n , :Y� ` Aittr.s aLE FOR V �?lYJ (� �� 9CSiGNT 10N S House Number Street Hamlet . wr y ... .S.N A•'ln,.;41 1 f 2 ✓� County Tax Map No. 1000 Section 1 �� Block �•�`'?,, Lot J, o ` Subdivision Filed Map No. Lot i 0 4,,, . State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy b. Intended use and occupancy 3. Nature of work(check which applicable): New Building Addition Alterati n Repair Removal Demolition Other Work .5O\ovr ,Pc tip etzre1.i 1 (Description) 4. Estimated Cost 311 , ti b o Fee (To be paid on filing this application) 5. If dwelling, number of dwelling units Number of dwelling units on each floor tAo, If garage, number of cars t_4(6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. Dimensions of existing structures, if any: Front Rear Depth Ij - Height Number of Stories Dimensions of same structure with alterations or additions: Front Rear Depth Height Number of Stories 8. Dimensions of entire new construction: Front Rear Depth Height Number of Stories 4c9. Size of lot: Front Rear Depth W0. Date of Purchase Name of Former Owner *] 1. Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law, ordinance or regulation? YES NO}� 13. Will lot be re-graded? YES NO_ Will excess fill be removed from premises? YES NO x- 14. Names of Owner of premises ye � i ne Sty . Address ( �?,b �'Dt�l(Newa�,A,,��pne No./� ;. Name of Architect avhil- U,ni AddressC vnLw6j !Prlone Nona' 9b3 1 i') Name of Contractor 5D\ar C446—V.et-Lek,terAddress Cla', im t,10l� hone No. (' 02 . . 'IVPP 1 ne-r 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO * IF YES, SOUTHOLD TOWN TRUSTEES & D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey,to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. 18. Are there any covenants and restrictions with respect to this property? * YES NO * IF YES, PROVIDE A COPY. STATE OF NEW YORK) SS: COUNTY 6 1 ) __ Er- Z--------- being duly sworn, deposes and says that(s)he is the applicant (Name o individual signing contract) above named, (S)He is the k4CLAIALeet-) 6 4-6 av I c to i'9ik (Contractor, Agent, Corporate'Officer, etc.) tIIlu„ of said owner or owners, and is duly authorized tgp�roryq 'Pie performed the said'work and to make and file this application; that all statements contained in this applicationdasrpwvj't .rask his knowledge and belief; and that the work will be performed in the manner set forth in the appli.C'atooy�f ,Eb r�.V:jt}. O ire i o�°to.: y Sworn to efore me thi 1,,,,' I _�. eeoe yi7�N�� _ 3 day'of t�'�( 20 ,` '.rb D'�-'o oH: '.r- . \tA. 41/1 WA! Notary Pub is Signature of Applicant • Scott A. Russell ttI• SSC' O RMWA\T)ER SUPERVISOR \NAAG]EM ENT SOUTHOLD TOWN HALL-P.O.Box 1179 pSOUTHOLD, • • Ni\ 53095 Main Road- NEW YORK 11971 �' . Town of So u th o l d CHAPTER 236 - STORMWATER MANAGEMENT WORK SHEET ( TO BE COMPLETED BY THE APPLICANT ) DOES THIS PROJECT INVOLVE ANY OF THE FOLLOWING: Yes (CHECK ALL THAT APPLY) No ❑ A Clearing, grubbing, grading or stripping of land which affects more than 5,000 square feet of ground surface. ❑ B Excavation or filling involving more than 200 cubic yards of material ❑1E1/ within any parcel or any contiguous area. C. Site preparation on slopes which exceed 10 feet vertical rise to 100 feet of horizontal distance. ❑6D. Site preparation within 100 feet of wetlands, beach, bluff or coastal erosion hazard area. ❑ E. Site preparation within the one-hundred-year floodplain as depicted . on FIRM Map of any watercourse. ❑ F. Installation of new or resurfaced impervious surfaces of 1,000 square - feet or more, unless prior approval of a Stormwater Management Control Plan was received by the Town and the proposal includes in-kind replacement of impervious surfaces. If you answered NO to all of the questions above, STOP! Complete the Applicant section below with your Name, Signature, Contact Information, Date & County Tax Map Number! Chapter 236 does not apply to your project. If you answered YES to one or more of the above, please submit Two copies of a Stormwater Management Control Plan and a completed Check List Form to the Building Department with your Building Permit Application. APPLICANT: (Property Owner,Design Profess' nal,Agent,Contractor,Other) S.C.T.M. #: 1000 Date District i at 1`, `/�/� NAME: hal_,A& wrmrw "�- Section Block Lot 1"--- . . tS'gl'°'"rd :�x :f FOR BUILDING DEPARTMENT USE ONLY fig'" r Contact Information: 10 DAP[idcphane Number) ��yyAi/ Reviewed By: Date: 9 - 0 - 14( Property Address/Location of Construction Work: Approved for processing Building Permit- J It�tl> " Stormwater Management Control Plan Not Required. tailiaa Ei Stormwater Management Control Plan is Required. 411111. (Forward to Engineering Department for Review.) FORM " SMCP-TOS MAY 2014 Town Hall Annex ; * Telephone(631)765-1802 54375 Main Road p�aaxx(631)765 5�2 P.O.Box 1179 G Q 1� roger.ricitert ,lOWr1.SOUt�O .nV.US Southold,NY 11971-0959 �'Q y0',1 , COU(VIOXYJI'11 BUILDING DEPARTMENT TOWN OF SOUTHOLD APPLICATION FOR ELECTRICAL INSPECTION - : REQUESTED BY: J 1-e Ca �- Date: //2 J11f Company Name: -.-3"D\ r- ccL\ Name: "' GC SD,�, � irL License No.: Address: - lDtbr Tare i-e_DkJ l`� �( • Phone No.: 2D J V JOBSITE INFORMATION: (*Indicates required information) *Name: £v \ � rupSk *Address: � urvi u(-Pua Q ue *Cross Street: �� *Phone No.: C31) a'- L g Permit No.: 36t 1,a- Tax•Map District: 1000 Section: Block: Lot: *BRIEF DESCRIPTION OF WORK(Please Print Clearly) • �� -1 (Please Circle All That Apply) *Is job ready for inspection: YES/ Rough In Final *Do-you need a Temp Certificate: Gi)/ NO Temp Information (If needed) *Service Size: 1 Phase 3Phase 100 150 200 300 350 400 Other *New Service: Re-connect Underground Number of Meters Change of Service Overhead Additional Information: PAYMENT DUE WITH APPLICATION 82-Request for Inspection Form _ F XJ'J if� �J gfik o ;SolarCit R„ JAN 15 2016 I 1/13/2016 _.- Town of Southold Attn: Building Department 54375 Route 25 P.O. Box 1179 Southold, NY 11971 Property Address: 2230 Soundview Ave, Mattituck Dear Department of Buildings, Enclosed are the amended plans for the above property location. Permit# 39228 Issued 9/30/14. Please contact me for anything else needed or if you have any questions. Thank you! Regards, Natalie Pera Permits Coordinator (631) 636-2990 npera@solarcity.corn 923 Motor Parkway,Ste C Hauppauge,NY 11788 r(631)625-9800 (888)SOL-CITY F(631)234-0146 solarcity.com AZ ROC 243771/ROC 245450'RCC277498 CA UC0888104,CO EC8041,CT HIC 0632778/ELC 012E305 DC 97110148EJECC902565 HI CT-29770 MA HIC 168572,MD MHIC 128948 NJ 1JJHIC+113VH061806G0/34EB01732700,OR CB1804981C562'PB1102 PA HICPA077343,TX TECL27006 WA SCLARC191901/SOLPRC'905P7 0 2013 SolarClty All ngnls reserved ,of iii��•-• ge Town Hall Annex41 la, of ® • Telephone(631)765-1802 54375 Main Road 111 * Fax(631)765-9502 P.O.Box 1179 G t , Southold,NY 11971-0959 ` f =t. C®UNr(,* 011 March 31, 2016 BUILDING DEPARTMENT TOWN OF SOUTHOLD Solar City 923 Motor Parkway, Suite C Hauppauge, NY 11788 RE: Krupski, 2230 Soundview Ave, Mattituck TO WHOM IT MAY CONCERN: The Following Items(if Checked)Are Needed To Complete Your Certificate of Occupancy: Note: Certification required by an architect or engineer stating the panels were installed per NYS Building Code. Application for Certificate of Occupancy. (Enclosed) Electrical Underwriters Certificate. A fee of$50.00. Final Health Department Approval. Plumbers Solder Certificate. (All permits involving plumbing after 4/1/84) Trustees Certificate of Compliance. (Town Trustees#765-1892) Final Planning Board Approval. (Planning#765-1938) Final Fire Inspection from Fire Marshall. Final Landmark Preservation approval. Final inspection by Building Dept. Final Storm Water Runoff Approval from Town Engineer BUILDING PERMIT - 39228 - Solar Panels °D kSolarCit ® APR 8 2016 BUILDING DEPT. TOWN OF SOUTHOLD April 4, 2016 Town of Southold Building Dept. Town Hall Annex 54375 Route 25 PO Box 1179 Southold NY 11791 Dear Inspector, I am submitting the post installation letter for: 2230 Soundview Ave Permit #39228 If there is anything else you may require of me, please do not hesitate to contact me at the phone number below or via email. Regards, c9ina 6 aaene Gina Capone 631-835-7394 gcapone@solarcity.corn 923 Motor Parkway,Ste C Hauppauge,NY 11788 T(631)625-9800 (888)SOL-CITY F(631)234-0146 solarcity.com AZ HOC 243/r1/ROC 2-15 150/F1OC277155,CA L104888104 CO EC8041 CT HIC 06'32/78/LLC 5125305 DC#i 1101486/ECC90258S,I II CT 29r 70,MA HID 108572,MD MHIC 128018 NJ NJHICT 13VH00160000,34F801732700 OR CF3160493/CGG,/P81102 PA HICPAO7 7343 TX TPCL27006 LVA SOLAR-D 01901,SOLARC-005P7 C)2013 SoL,rC,ly All nahts rem ved STATE OF NEW YORK WORKERS'COMPENSATION BOARD CERTIFICATE OF NYS WORKERS' COMPENSATION INSURANCE COVERAGE la.Legal Name&Address of Insured(Use street address only) lb.Business Telephone Number of Insured (650)963-5100 SolarCity Corporation 3055 Clearview Way j ic.NYS Unemployment Insurance Employer San Mateo,CA 94402 Registration Number of Insured 49-892777 Work Location of Insured(Only required if coverage is specifically limited to certain locations in New York State, i.e., a Wrap-Up ld.Federal Employer Identification Number of Insured Policy) or Social Security Number 02-0781046 3a. Name of Insurance Carrier 2.Name and Address of the Entity Requesting Proof of Liberty Insurance Corporation Coverage(Entity Being Listed as the Certificate Holder) ' 3b.Policy Number of entity listed in box"la" WA7-66D-066265-024 Town of Southold 980 Hawkins Ave. 3c. Policy effective period PO Box 708 Lake Grove,NY 11755 9/1/2014 to 9/1/2015 3d. The Proprietor,Partners or Executive Officers are ❑ included. (Only check box if all partners/officers included) X all excluded or certain partners/officers excluded. This certifies that the insurance carrier indicated above in box "3" insures the business referenced above in box "l a" for workers' compensation under the New York State Workers'Compensation Law.(To use this form,New York(NY)must be listed under Item 3A on the INFORMATION PAGE of the workers'compensation insurance policy). The Insurance Carrier or its licensed agent will send this Certificate of Insurance to the entity listed above as the certificate holder in box"2". The Insurance Carrier will also notifi)the above certificate holder within 10 days IF a policy is canceled due to nonpayment ofpremiums or within 30 days IF there are reasons other than nonpayment of premiums that cancel the policy or eliminate the insured from the coverage indicated on this Certificate. (These notices may be sent by regular mail.) Otherwise,this Certificate is valid for one year after this form is approved by the insurance carrier or its licensed agent,or until the policy expiration date listed in box"3c",whichever is earlier. Please Note: Upon the cancellation of the workers' compensation policy indicated on this form,if the business continues to be named on a permit,license or contract issued by a certificate holder,the business must provide that certificate holder with a new Certificate of Workers' Compensation Coverage or other authorized proof that the business is complying with the mandatory coverage requirements of the New York State Workers'Compensation Law. Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has the coverage as depicted on this form. Approved by: Theresa Fagan CA Licen 0C12887 (P.nt name of authorized representative or licensed agent of insurance carrier) Approved by: !'�,, I 9/1/14 (Signature) (Date) Title: Client Service Coordinator Telephone Number of authorized representative or licensed agent of insurance carrier: 213-443-0775 Please Note: Only insurance carriers and their licensed agents are authorized to issue Form C-105.2. Insurance brokers are NOT authorized to issue it. C-105.2(9-07) www.wcb.state.ny.us it Acc•R O® CERTIFICATE OF LIABILITY INSURANCE DATE(MMIDD/YYYY) 08/2912014 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies) must be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT MARSH RISK&INSURANCE SERVICES PHO 345 CALIFORNIA STREET,SUITE 1300 PHONNEE FAX (AIC.No.Ext): (A/C,No): CALIFORNIA LICENSE NO 0437153 EMAIL SAN FRANCISCO,CA 94104 ADDRESS INSURER(S)AFFORDING COVERAGE NAIC# 998301-STND-GAWUE-14-15 INSURER A:Liberty Mutual Fire Insurance Company 16586 INSUREDINSURER B•Liberty Insurance Corporation 42404 Ph(650)963-5100 SolarCity Corporation INSURER C.N/A N/A 3055 Clearview Way INSURER D San Mateo,CA 94402 INSURER E: INSURER F: COVERAGES CERTIFICATE NUMBER: SEA-002440269-02 REVISION NUMBER:4 THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS INSR TYPE OF INSURANCE ADDL SUBR POLICY EFF POLICY EXP WLIMITS LTR INSR VD POLICY NUMBER (MMIDD/YYYY) (MM/DDIYYYY) A GENERAL LIABILITY TB2-661-066265-014 09/01/2014 09/01/2015 EACH OCCURRENCE _ $ 1,000,000 DAMAGE TO RENTED 100,000 X COMMERCIAL GENERAL LIABILITY PREMISES(Ea occurrence) $ CLAIMS-MADE X OCCUR MED EXP(Any one person) $ 10,000 PERSONAL&ADV INJURY $ 1,000,000 GENERAL AGGREGATE _ $ 2,000,000 GEN'L AGGREGATE LIMITAPPLIES PER PRODUCTS-COMP/OP AGG $ 2,000,000 POLICY X JE o n LOG Deductible $ 25,000 A AUTOMOBILE LIABILITY AS2-661-066265-044 09/01/2014 09/01/2015 COMBINED SINGLE LIMIT 1,000,000 (Ea accident) X ANY AUTO BODILY INJURY(Per person) $ ALL OWNED SCHEDULED BODILY INJURY(Per accident) $ AUTOS AUTOS XX NON-OWNED PROPERTY DAMAGE HIRED AUTOS AUTOS (Per accident) X Phys Damage COMP/COLL DED. $ $1,000/$1,000 UMBRELLA LIAB _ OCCUR EACH OCCURRENCE $ EXCESS LIAB CLAIMS-MADE AGGREGATE $ DED RETENTION$ $ B WORKERS COMPENSATION WA7-66D-066265-024 09/01/2014 09/01/2015 X WCSTATU- OTH- AND EMPLOYERS'LIABILITY TORY LIMITS ER B ANY PROPRIETOR/PARTNER/EXECUTIVE Y/N WC7-661-066265-034(WI) 09/01/2014 09/01/2015 E L EACH ACCIDENT $ 1,000,000 B OFFICER/MEMBER EXCLUDED? N N/A WC DEDUCTIBLE.$350,000' 1,000,000 (Mandatory in NH) E L DISEASE-EA EMPLOYEE $ If yes,descnbe under 1,000,000 DESCRIPTION OF OPERATIONS below E L DISEASE-POLICY LIMIT $ DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES (Attach ACORD 101,Additional Remarks Schedule,if more space is required) Evidence of Insurance. CERTIFICATE HOLDER CANCELLATION SolarClty Corporation SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE 3055 Clearview Way THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN San Mateo,CA 94402 ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE of Marsh Risk&Insurance Services Charles Marmolejo ©1988-2010 ACORD CORPORATION. All rights reserved. ACORD 25(2010/05) The ACORD name and logo are registered marks of ACORD A ® CERTIFICATE OF LIABILITY INSURANCE DATE /YYYY) 09/03/2014/2014 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(les) must be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT MARSH RISK&INSURANCE SERVICES NAME: NE FAX 345 CALIFORNIA STREET,SUITE 1300 INC.No.Ext): (NC,No): CALIFORNIA LICENSE NO.0437153 E-MAIL SAN FRANCISCO,CA 94104 ADDRESS: INSURER(S)AFFORDING COVERAGE NAIC# 998301-STND-GAWUE-14-15 INSURER A:Liberty Mutual Fire Insurance Company 16586 INSURED INSURER B:Liberty Insurance Corporation 42404 Ph(650)963-5100 SolarCity Corporation INSURER C:N/A N/A 3055 Clearview Way INSURER D: San Mateo,CA 94402 INSURER E: INSURER F: COVERAGES CERTIFICATE NUMBER: SEA-002493840-01 REVISION NUMBER:1 THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS INSR TYPE OF INSURANCE ADDL SUBR POLICY EFF POLICY EXP LTR INSR WVD POLICY NUMBER (MMIDD/YYYY) (MM/DD/YYYY) LIMITS A GENERAL LIABILITY TB2-661-066265-014 09/01/2014 09/01/2015 EACH OCCURRENCE $ 1,000,000 X COMMERCIAL GENERAL LIABILITY DAMAGE TO RENTED 100,000 PREMISES(Ea occurrence) $ CLAIMS-MADE X OCCUR MED EXP(Any one person) $ 10,000 PERSONAL&ADV INJURY $ 1,000,000 GENERAL AGGREGATE $ 2,000,000 GEN'L AGGREGATE LIMIT APPLIES PER PRODUCTS-COMP/OP AGG $ 2,000,000 71 POLICY X jEei n LOC Deductible $ 25,000 A AUTOMOBILE LIABILITY AS2-661-066265-044 09/01/2014 09/01/2015 COMBINED SINGLE LIMIT 1,000,000 (Ea accident) _ $ X ANY AUTO BODILY INJURY(Per person) $ X ALL OWNED X SCHEDULED BODILY INJURY $ AUTOS _ AUTOS (Per accident) X HIRED AUTOS x AUTOSSED PROPERTY accDAMAGE(Pe ) $ X Phys.Damage COMP/COLL DED. $ $1,0001$1,000 B X UMBRELLA LIAB X OCCUR TH7-661-066265-014 09/01/2014 09/01/2015 EACH OCCURRENCE — $ 10,000,000 EXCESS LIAB CLAIMS-MADE AGGREGATE $ 10,000,000 DED X RETENTION$10,000 $ B WORKERS COMPENSATION WA7-66D-066265-024 09/01/2014 09/01/2015 X WC STATU- OTH- B y/N WC7 WI- - - AND EMPLOYERS'LIABILITY 661066265034 TORY LIMITS ER ANY PROPRIETOR/PARTNER/EXECUTIVE ( ) 09/01/2014 09/01/2015 E L EACH ACCIDENT $ 1,000,000 BOFFICER/MEMBER EXCLUDED? N N/A (Mandatory In NH) 'WC DEDUCTIBLE:$350,000' E L DISEASE-EA EMPLOYEE $ 1,000,000 If yes,descnbe under 1,000,000 DESCRIPTION OF OPERATIONS below E L DISEASE-POLICY LIMIT $ DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES (Attach ACORD 101,Additional Remarks Schedule,If more space is required) Evidence of insurance CERTIFICATE HOLDER CANCELLATION Town of Southold SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE 980 Hawkins Ave. THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN PO Box 708 ACCORDANCE WITH THE POLICY PROVISIONS. Lake Grove,NY 11755 AUTHORIZED REPRESENTATIVE of Marsh Risk&Insurance Services I Charles Marmolejo Com'/,L--'---0"-C-- CD 1988-2010 --0"-C--©1988-2010 ACORD CORPORATION. All rights reserved. ACORD 25(2010/05) The ACORD name and logo are registered marks of ACORD 4 AJ CERTIFICATE OF LIABILITY INSURANCE DATE(MoDmW) THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies) must be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT MARSH RISK& INSURANCE SERVICES PHON: 345 CALIFORNIA STREET,SUITE 1300 (A/CC.N No.Ext):E FAX No): CALIFORNIA LICENSE NO.0437153 E-MAIL SAN FRANCISCO,CA 94104 ADDRESS: Attn:Shannon Scott 415.743-8334 INSURER(S)AFFORDING COVERAGE NAIC# 998301-STND-GAWUE-15-16 INSURER A:Zurich Amencan Insurance Company 16535 INSURED INSURER B:American Zurich Insurance Company 40142 SolarCity Corporation 3055 Clearview Way INSURER C:N/A N/A San Mateo,CA 94402 INSURER D INSURER E: INSURER F: COVERAGES CERTIFICATE NUMBER: SEA-002681782-03 REVISION NUMBER:4 THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. . INSR TYPE OF INSURANCE ADDL SUBR POLICY EFF POLICY EXP LIMITS LTR INSD WVD POLICY NUMBER (MMIDD/YYYY) (MMIDD/YYYY) A X COMMERCIAL GENERAL LIABILITY GL0018201600 09/01/2015 09/01/2016 EACH OCCURRENCE $ 3,000,000 AMAGE TO CLAIMS-MADE X OCCUR P REMISES(Ea occurrence) $ 3,000,000 MED EXP(Any one person) $ 5,000 PERSONAL&ADV INJURY $ 3,000,000 GE 'L AGGREGATE LIMIT APPLIES PER GENERAL AGGREGATE $ 6,000,000 POLICY PRO XLOC PRODUCTS $ 6,000,000 JECT _ OTHER SIR $ 250,000 A AUTOMOBILE LIABILITY BAP018201700 09/01/2015 09/01/2016 COMBINED SINGLE LIMIT $ 5,000,000 (Ea accident) _ X ANY AUTO BODILY INJURY(Per person) $ X ALL OWNED X SCHEDULED BODILY INJURY(Per accident) $ AUTOS AUTOS X HIRED AUTOS x AUT SEED PPeracciidentDAMAGE $ Deductible $ 100,000 UMBRELLA LIAB OCCUR EACH OCCURRENCE $ EXCESS UAB CLAIMS-MADE AGGREGATE $ DED RETENTION$ $ 9 WORKERS COMPENSATION WC018201400 09/01/2015 09/01/2016 X PER OTH- A AND EMPLOYERS'LIABILITY YIN WC018201500 MA 09/01/2015 09/01/2016 STATUTE ER ANY PROPRIETOR/PARTNER/EXECUTIVE N N/A ( ) E L EACH ACCIDENT $ 1,000,000 OFFICER/MEMBER EXCLUDED? (Mandatory In NH) E.L.DISEASE-EA EMPLOYEE $ 1,000,000 If yes,descnbe under DESCRIPTION OF OPERATIONS below E.L DISEASE-POLICY LIMIT $ 1,000,000 DESCRIPTION OF OPERATIONS!LOCATIONS I VEHICLES(ACORD 101,Additional Remarks Schedule,may be attached If mom space Is required) Evidence of insurance. CERTIFICATE HOLDER CANCELLATION Town of Southold SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE 54375 Main Road THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Southold,NY 11971-0959 ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE of Marsh Risk&Insurance Services Charles Marmole/o C. .,j��/(—_:- . I ©1988-2014 ACORD CORPORATION. All rights reserved. ACORD 25(2014/01) The ACORD name and logo are registered marks of ACORD 1 ' --._ - . . SUFFOLK COUNTY DEFr OF LABOR. ',4 LICENSING&CONSUMER AFFAIRS HOME IMPROVEMENT •• 1,... . '-",li CONTRACTOR UCENSE --! —I. SHAUN E CHAPMAN -,:-,* 0 This certifies that the em2"="mE bearer is duly SOLAR COY CORPORATION Guessed by the • LicometarrZar Dr isave County of Suffolk 52057-H 08(01/2013 X....s(.,46) - 08101/2017 SUFFOLK COUNTY DEPT OP LABOR tv•i:,,,,,,, „ 110ENSING a CONSUMER AFFAIRS . . MASTER 1 iO. • ..e -- ELECTRICIAN , .,e-, NigliL* -' JASON KANE 6ffiNsimisavaina Tits eelle3 ttcI the 1mt bearer is duly SOLAR WY CORP. • iiceiteed by ow County 07Suffelk 51331-ME 03/18/2013 I ZA.10"...!...dr mikee....m.,,,, 1 amunixecom ceimarra 1 • • • . • • SUFFOLK COUt!•IY 1 n-AT OP LABOR. i ,/ I •MAR I'Lii 111 14.:TRICIAN ---=-",.2., g `- °i .IASet KANE f Un ,.. •:-,,:,. _2h a rcrtitlG:.that lha •j" - ac AIz CITY 8o11P 116aPAP to duly lloonaad by gIi Nnn, bounty of Suffolk - 11.•o.,,w. CS.r..,,Fi `f•, 'I X31=f1- n�'16IJ.Ili.I .0,lura., I 01114..:UNTO 03/O1/m'1116 i,. $UF4 OLc<COUNTY DV P OP i A®®N 1 I` MOMLIfu k-ovirtiAtNI` CONTRACTOR • SHAUN a CHAPMAN 89LNIt CITY C®flPalnram homer to duly a licznood by Ihoi /0(.1a7-H.---------..161.14;m14 - . I Cnuuly of Rattail/ - 1 4" Oninii20i5 I f ri Version#37.4 %tSolarCity 3055 Clearview Way,San Mateo, CA 94402 etif �+ (888)-SOL-CITY (765-2489) I www-solarcity-com MAe actr046. June 25,2014 * ".f 4 f' Project/Job# 119179gIC RE: CERTIFICATION LETTER . W Project: Krupski Residence 2230 Soundview Ave 9•18Z5 Mattituck,NY 11952 eset 0' To Whom It May Concern, Amir Massoum 2014.06.26 10:45:39-07'00' A jobsite survey of the existing framing system was performed by a site survey team from SolarCity. Structural review was based on site observations and the design criteria listed below: Design Criteria: -Applicable Codes= 2010 Residential Code of NY State,ASCE 7-05,and 2005 NDS -Risk Category=II -Wind Speed = 120 mph,Exposure Category C -Ground Snow Load =20 psf -MP1: Roof DL= 13.5 psf,Roof LL/SL= 13 psf(Non-PV Areas),Roof LL/SL=6 psf(PV Areas) -MP2: Roof DL= 8.5 psf,Roof LL/SL= 15.5 psf(Non-PV Areas),Roof LL/SL= 7.6 psf(PV Areas) -MP3: Roof DL= 8.5 psf, Roof LL/SL= 13 psf(Non-PV Areas), Roof LL/SL= 6 psf(PV Areas) -MP4: Roof DL= 13.5 psf,Roof LL/SL= 13 psf(Non-PV Areas),Roof LL/SL=6 psf(PV Areas) Note: Per IBC 1613.1; Seismic check is not required because Ss =0.20083 < 0.4g and Seismic Design Category(SDC) = B < D On the above referenced project,the structural roof framing has been reviewed for loading from the PV assembly on the roof.The structural review only applies to the section(s)of the roof that directly supports the PV system and its supporting elements.After this review it was determined that the existing structure is adequate to carry the PV system loading. I certify that the structural roof framing and the new attachments that directly support the gravity loading from PV modules have been reviewed and determined to meet or exceed requirements of the 2010 Residential Code of NY State. Please contact me with any questions or concerns regarding this project. Sincerely, Amir Massoumi,P.E. Civil Engineer Direct: 650.963.5611 email: amassoumi@solarcity.com 3055 Clearview Way San Mateo,CA 94402 r(650)638-1028 (888)SOL-CITY F(650)638-1029 solarcity.com A2 ROC 2'377, CS COLO 305104,Co E.60.1 C IC 0632776 Dt.,H•C 71101466 DC HIS 71101488 HI CT 20770 MA i1IC 171572 MD MHIC 12o040 NJ 1JVH06160600 OR CCI31t)111)13 PA 077.;11 TI MLR 2,005.SA CCL SO1.AM-101907 :013 SWII,Cly All;19tit;t resmlerL , �►/� 06.25.2014 !bSoIarCity SleekMountTm PV System Version#37.4 Structural Design Software r + __ �� PROJECT INFORMATION &TABLE OF CONTENTS 1 Project Name: _Krupski Residence ___ AHJ:_ Southold Town _ Job Number: 119179 Building Code:_ 2010 Residential Code of NY State -- �__ Customer Name: Krupski,Eugene Based On: _ IRC 2006/IBC 2006 ___ Address: 2230 Soundview Ave__ ASCE Code: ASCE 7-05 _ City/State:__ _Mattituck, _ NY_ _ Risk Category __ II _ _� Zip Code.__ _11952 _ Upgrades Req'd?_A______ No —_ Latitude/Longitude:___ 41.018i50___,_._.-72.537380 ___ _ Stamp Req'd?�__ ___ Yes _ ___- SC Office: _ Long Island , PV Designer.-F Jeff Bunca Calculations: Tadei Shayo EOR: _ Amir Massoumi, P.E. Certification Letter 1 Project Information,Table Of Contents, &Vicinity Map 2 Structure Analysis (Loading Summary and Member Check) 3 Hardware Design (PV System Assembly) 4 Note: Per IBC 1613.1; Seismic check is not required because Ss=0.20083 < 0.4g and Seismic Design Category(SDC) = B < D F----------7—— __-_:--- ^-.__-._. -------1-1-MILE __,_.__-._ 12-MILE VICINIr MAP .., ,Y---` .(4 I. ./ * *at ', 'i t‘...,1 d ,,,,,,,,,1. •, `F :. , L X i � i Tye. 's, � P� $44 - '''-‘A; 4. ' N., A „,,, z.... ,,,...„ ,„,„ • , . .„.. ,.., . - ‘, ,„ 4,_ •,,, , , d , . .. .c ,, ; ,, , , , A ,,,, 40 "1 - ' , 'a a 2-41 Goole Irna 'e : + 2x014 Di•italGlobe\New York,GIS, USDA Farm Service:A•enc 2230 Soundview Ave, Mattituck, NY 11952 Latitude:41.01875,Longitude:-72.53738,Exposure Category:C 'STRUCTURE ANALYSIS - LOADING SUMMARY AND MEMBER CHECK- MP1 Member Properties Summary MP1 Horizontal Member Spans Rafter Properties Overhang 1.16 ft Actual W 1.50" Roof System Properties Span 1 12.50 ft Actual D 9.25" Number of Spans(w/o Overhang), 1 Span 2 Nominal Yes Roofing Material Comp Roof Span 3 A 13.88 in.^2 Number of Layers(Comp Only) ( 1 Layers) Span 4 SX 21.39 in.^3 Re-Roof to 1 Layer of Comp? No Span 5 Ix 98.93 in.^4 Plywood Sheathing Yes Total Span 13.66 ft TL Defl'n Limit 180 Board Sheathing None PV 1 Start 2.58 ft Wood Species SPF Vaulted Ceiling Yes PV 1 End 12.33 ft Wood Grade #2 Rafter Slope 43° PV 2 Start Fb 875 psi Rafter Spacing 16"O.C. PV 2 End F„ 135 psi Top Lat Bracing Full PV 3 Start E 1400000 psi Bot Lat Bracing Full PV 3 End Emin 510000 psi, Member Loading Summary Roof Pitch 11/12 Initial Pitch Adjust , Non-PV Areas PV Areas Roof Dead Load DL 13.5 psf x 1.37 18.5 psf 18.5 psf PV Dead Load PV-DL 3.0 psf x 1.37 4.1 psf Roof Live Load RLL 20.0 psf x 0.65 13.0 psf Live/Snow Load LL/SL1'2 20.0 psf x 0.48 I x 0.3 9.6 psf 6.0 psf Total Load TL 31.5 psf 28.6 psf Notes: 1. ps=Cs*pf;Cs-roof,Cs-pv per ASCE 7[Figure 7-2] 2. pf=0.7(CO(Ct)(Is)pg; Ce=Ct=IS 1.0; Member Design Summa (per NDS) Governing Load Comb CD CL(+) CL(-) CF Cr D+S 1.15 1.00 1.00 1.1 1.15 Member Analysis Results Summary Maximum Max Demand @ Location Capacity DCR Shear Stress 28 psi 1.2 ft. 155 psi 0.18 Bending(+)Stress 411 psi 7.5 ft. 1273 psi 0.32 (Governs) Bending(-)Stress -16 psi 1.2 ft. -1273 psi 0.01 Total Load Deflection 0.15 in. 7.4 ft. L/1010 0.18 ;CALCULATION OF DESIGN WIND LOADS_=MPl j Mounting Plane Information Roofing Material __ Comp Comp Roof _ PV System Type_ __ _ SolarCity SleekMountT"' _, — T__ – Spanning Vents _ _ No _ Standoff(Attachment Hardware) - M _ _Comp Mount Type C- Roof Slope _ __ __ O.C. � 43° �! _ _ Rafter Spacing— __0__ ____ _i _ 16" _ __ Framing Type/Direction Y-Y Rafters _,_ Purlin-Spacing_______ ___ X-X Purlins Only_ NA _ �_ �__—_ Tile Reveal _ Tile Roofs Only NA _ Tile Attachment System - __ Tile Roofs Only_ +-- NA s~� Standing Seam Spacing SM Seam Only NA Wind Design Criteria Wind Design Code __ ASCE 7-05 Wind Design Method _ � _ _ Partially/Fully Enclosed Method Basic Wind Speed _ V _ 120 mph —_ Fig_6-1 Exposure Category _ __ _�- C - _Section 6.5.6.3 _ Roof Style _� _ ^_y �� Gable/Hip Roof �� Fig.6-11B/C/D-14A/B Mean Roof Height h . 25 ft Section 6.2 Wind Pressure Calculation Coefficients Wind Pressure Exposure _ _ KZ _ 0.95 _ Table 6-3 Topographic Factor �~__ __Krt _ ^,� 1.00 - Section 6.5.7 Wind_Directionality Factor Kd 0.85 Table_6-4 Importance __ _ _ Factor I - _ _ _ ___ 1.0 _ .________ __ Table 6-1 Velocity Pressure qh qh =0.00256(Kz)(Kzt) N (Kd) ^2)(I) Equation 6-15 29.6 psf ' Wind Pressure ' Ext. Pressure Coefficient(Up) GCo(Uo) -0.95 Fig.6-11B/C/D-14A/B Ext. Pressure Coefficient(Down) GCo(Down) 0.88 - Fig.6-11B/C/D-14A/B Design Wind Pressure p p=qh(GC0) Equation 6-22 Wind Pressure Up p(pp) - -28.2 psf - Wind Pressure Down P down) 25.9 psf ' ALLOWABLE STANDOFF SPACINGS !_ i -X-Direction . Y-Direction Max Allowable Standoff Spacing __ _Landscape 64" 39" Max Allowable Cantilever -_ __ Landscape ___ _ - 23" _ __ _ _ _ NA Standoff Configuration Landscape Staggered Max Standoff Tributary Area Trib i________-__ 17 sf_ __- _ _ PV Assembly Dead Load_ _ W-PV _ 3 psf _ __ Net Wind Uplift at Standoff_ _ - T-actual_Y __ - _-465 lbs _m' __ ^' _ Uplift Capacity of Standoff _ __ T-allow _��___ 500 lbs Standoff Demand/Capacity - DCR 93.0% X-Direction Y-Direction Max Allowable Standoff Spacing Portrait _ 32" _ 65" Max Allowable Cantilever ___�^ Portrait_ ___14" _ _ NA Standoff Configuration Portrait –� Staggered — Max Standoff Tributary Area_-_ a _ Trib _ _ 14 sf _ _ PV Assembly Dead Load _ _ W-PV _ 3 psf _ Net Wind uplift at Standoff - T-actual ___ __ �� 388 lbs ___ Uplift Capacity of Standoff T-allow 500 lbs Standoff Demand/Capacity - DCR ---77.5% __ __._ (STRUCTURE ANALYSIS - LOADING SUMMARY AND MEMBER CHECK - MP2 I Member Properties Summary MP2 _ Horizontal Member Spans Rafter Properties Overhang 1.16 ft Actual W 1.50" Roof System Properties Span 1 17.83 ft Actual D 9.25" Number of Spans(w/o Overhang) 1 Span 2 Nominal Yes Roofing Material Comp Roof Span 3 A 13.88 in.^2 Number of Layers(Comp Only) ( 1 Layers) Span 4 Sx 21.39 in.^3 Re-Roof to 1 Layer of Comp? No Span 5 Ix 98.93 in.^4 Plywood Sheathing Yes - Total Span 18.99 ft TL Defl'n Limit 120 Board Sheathing - None _ PV 1 Start 3.83 ft Wood Species SPF Vaulted Ceiling No PV 1 End 17.67 ft Wood Grade #2 Rafter Slope 350 PV 2 Start Fb 875 psi Rafter Spacing 16"O.C. PV 2 End F„ 135 psi Top Lat Bracing - Full PV 3 Start E 1400000 psi Bot Lat Bracing At Supports PV 3 End Emin 510000 psi Member Loading Summary Roof Pitch 9/12 Initial Pitch Adjust Non-PV Areas PV Areas Roof Dead Load DL 8.5 psf x 1.22 10.4 psf 10.4 psf PV Dead Load PV-DL 3.0 psf x 1.22 3.7 psf Roof Live Load RLL 20.0 psf x 0.78 15.5 psf Live/Snow Load LL/SL1'2 20.0 psf x 0.62 I x 0.38 12.4 psf 7.6 psf Total Load. TL - 25.9 psf 21.6 psf Notes: 1. ps=Cs*pf;Cs-roof,Cs-pv per ASCE 7[Figure 7-2] 2. pf=0.7(Ce)(Ce)(Is)p9; Ce=Ct=Is=1.0; Member Design Summa (per NDS) Governing Load Comb CD CL(+) CL(-) CF Cr D+5. 1.15 1.00 0.30 1.1 1.15 Member Analysis Results Summary Maximum Max Demand @ Location Capacity DCR Shear Stress 31 psi 1.2 ft. 155 psi 0.20 Bending(+)Stress 644 psi 10.1 ft. 1273 psi 0.51 (Governs) Bending(-)Stress -13 psi 1.2 ft. -377 psi 0.03 Total Load Deflection 0.47 in. 10.1 ft. L/451 0.27 'CALCULATION OF DESIGN_WIND LOADS - MP2- _ _______1 Mounting Plane Information - Roofing Material _ _ _ Comp Roof _ - ^- __ PV System Type - _ _-_ .____— _Y_ _ - SolarCity SleekMountTM' _._ - Spanning Vents— _ __ No —_ _ Standoff(Attachment Hardware) '-Comp Mount Type C - - Roof Slope - _— __ - --_-,-- 35° _ _______,_________-- Rafter Spacing_-- •_-__-- ___-�__ __-- - J- _16"O.C. -- - - Framing Type/Direction Y-Y Rafters Purlin Spacing ,_--_ X-X Purlins Only_ -_i__ NA =_- _ ` Tile Reveal -_ Tile Roofs Only — NA _— Tile Attachment System ___ Tile Roofs Only-__. - NA _________ Standing Seam Spacing SM Seam Only NA Wind Design Criteria . Wind Design Code _ _ ASCE 7-05 — ~-�A_ Wind Design Method_-!_ _ y%Ful _ __ -__ Partiallly Enclosed Method _ _ ` Basic Wind Speed V _ _ 120 mph Fig. 6-1 Exposure Category,_. . ' ._- ' —__e C iSection 6.5.6.3 Roof Style_ __ Gable/Hip Roof Fig.6-11B/C/D-14A/B Mean Roof Height - -__ h-,__.__._ �__ a 25 ft _-__- Section 6.2 Wind Pressure Calculation Coefficients Wind Pressure Exposure_ _ ___ KZ _ _ _ 0.95 _ Table 6-3_ Topographic Factor _ s --_____-_Krt __-____`- 1.00 Section 6.5.7 _ Wind Directionality Factor Kd — 0.85 Table 6-4 Importance Factor -$- I___ __ _-_ -- 1.0 . , —____ Table 6-1 Velocity Pressure qh qh=0.00256(Kz)(Kzt) N (Kd) ^2)(I) Equation 6-15 29.6 psf Wind-Pressure Ext. Pressure Coefficient(Up) GC cum -0.95 Fig.6-11B/C/D-14A/B Ext. Pressure Coefficient(Down) GC,(Down) 0.88 Fig.6-11B/C/D-14A/B Design Wind Pressure p p=qh(GC0) Equation 6-22 Wind Pressure Up Nun) -28.2 psf Wind Pressure Down P downs - _ 25.9 psf OWABLETANDOFF SPACINGS �' - ALL1 X-Direction Y-Direction Max Allowable Standoff Spacing __ Landscape _ 64" 39" Max Allowable Cantilever , - Landscape ' __ -"23" - _ _ NA - Standoff Configuration Landscape Staggered Max Standoff Tributary Area_-____ Trib - _ 17 sf _ _- PV Assembly Dead Load -^ W-PV _- __ 3 psf Net-Wild-Uplift-it StandofftT-actual ___._ ____`__ �_ -462113i-_— _ _ _ Uplift Capacity of Standoff --^ T-allow _ 500 lbs — _ — Standoff Demand/Capacity DCR - '- 92.5%'-- - ' 2.5% - �- �� - X-Direction Y-Direction Max Allowable Standoff Spacing Portrait 32" _ _65" _ Max Allowable Cantilever _-_ Portrait ___ - ��_^ 14" -' - _ NA__— Standoff Configuration Portrait Staggered Max Standoff Tributary Area -„ ___ Trib __ _ ______ __ 14 sf _ ______ --_'_._ - __ PV Assembly Dead Load _ __ W-PV — 3 psf _ Net Wind Uplift at Standoff _ T-actual _ - -385 lbs_`_ - -"- Uplift Capacity of Standoff _ T-allow __ _ _ _ 500 lbs _ Standoff Demand/Capacity - DCR m �� --' 77.1% - ----------- ;STRUCTURE ANALYSIS - LOADING SUMMARY AND MEMBER CHECK- MP3 Member Properties Summary MP3 Horizontal Member Spans Rafter Properties Overhang 1.16 ft Actual W 1.50" Roof System Properties ' Span 1 10.75 ft Actual D 9.25" Number of Spans(w/o Overhang) 1 Span 2 Nominal Yes Roofing Material Comp Roof Span 3 - A 13.88 in.^2 Number of Layers(Comp Only) ( 1 Layers) Span 4 - SX 21.39 in.^3 Re-Roof to 1 Layer of Comp? No Span 5 Ix 98.93 in.^4 Plywood Sheathing Yes Total Span , 11.91 ft TL Defl'n Limit 120 Board Sheathing None PV 1 Start 5.75 ft Wood Species _SPF _ Vaulted Ceiling No PV 1 End 10.83 ft Wood Grade #2 Rafter Slope 43° PV 2 Start Fb 875 psi Rafter Spacing 16"O.C. PV 2 End F„ 135 psi Top Lat Bracing Full PV 3 Start E 1400000 psi Bot Lat Bracing At Supports PV 3 End Emin 510000 psi Member Loading Summary Roof Pitch 11/12 - Initial Pitch Adjust Non-PV Areas PV Areas , Roof Dead Load DL 8.5 psf x 1.37 11.6 psf 11.6 psf PV Dead Load PV-DL 3.0 psf x 1.37 4.1 psf Roof Live Load RLL 20.0 psf x 0.65 13.0 psf Live/Snow Load LL/SL1'2 20.0 psf x 0.48 I x 0.3 9.6 psf 6.0 psf Total Load TL 24.6 psf 21.7 psf Notes: 1. ps=Cs*pf;Cs-roof,Cs-pv per ASCE 7[Figure 7-2] 2. pf=0.7(Ce)(CO(Is)p9; Ce=Ct=Is=1.0; Member Design Summa (per NDS) Governing Load Comb CD CL(+) CL(-) CF Cr D+ S 1.15 1.00 0.48 1.1 1.15 Member Analysis Results Summary Maximum Max Demand @ Location Capacity DCR Shear Stress 19 psi 1.2 ft. 155 psi _ 0.13 Bending(+)Stress 241 psi 6.5 ft. 1273 psi 0.19 (Governs) Bending(-)Stress -12 psi 1.2 ft. -614 psi _ 0.02 Total Load Deflection 0.06 in. 6.5 ft. L/2006 0.06 jCALCULATION OFTDESIGN WIND LOADS - 14133__. _ � Mounting Plane Information Roofing Material ___ _ _ _�_ - Comp Roof _ PV System Type __ _ Solay_ l1ountTM _ Spanning Vents _ '----77-------'-r— _ No Standoff(Attachment Hardware) - _ Comp Mount Type C Roof Slope __ _ __ T_ 43° ^___ T_ Rafter Spacing__ -___ __ _ _____ __ 16"O.C. __ Framing Type/Direction Y-Y Rafters Purlin_Spacing____ X-X Purlins Only ___� _ NA _d_ __ Tile Reveal _ _ Tile Roofs Only ^ NA __ Tile Attachment System w __ Tile Roofs Only, _ ' _ NA `__w_ — Standing Seam Spacing SM Seam Only NA Wind Design Criteria , Wind Design Code _ __ ASCE 7-05 _ Wind Design Method____=___ �_� ___ __ Partially/Fully Enclosed Method' _,_____.__ T Basic Wind Speed _�� _V _ 120_mph _ Fig. 6-1 __ Exposure Category ___�___�_ ___ ___�__ __ - Section C6.5.6.3 Roof Style _ ___h--- MeGable/Hip Roof Fig.6-11B/C/D-14A/B Wein-Roof _�_ __Roof Height h 25 ft Section 6.i Wind Pressure Calculation Coefficients Wind Pressure Exposure _ KZ _ 0.95 _ _ Table 6-3 _ Topographic Factor — Ka ��_� 1.00 T` _ _�_ Section 6.5.7--- __ 6.5.7 - Wind Directionality Factor Kd 0.85 Table 6-4_^_ Importance Factor a—_ I_._.m ___ ________�____—. 1.0 _ Table 6-1 Velocity Pressure qh qh = 0.00256(Kz)(Kzt) N (Kd) ^2)(I) Equation 6-15 29.6 psf Wind Pressure Ext. Pressure Coefficient(Up) GCp amp') -0.95 Fig.6-11B/C/D-14A/B Ext.Pressure Coefficient(Down) GCp(D0,,,,,,) 0.88 Fig.6-11B/C/D-14A/B Design Wind Pressure _ p p=qh(GCp) Equation 6-22 Wind Pressure Up Pam - -28.2 psf Wind Pressure Down P dowel - 25.9 psf - (ALLOWABLE STANDOFF SPACINGS �;_' � •� __J X-Direction Y-Direction Max Allowable Standoff Spacing_ __ ^Landscape 64" 39" Max Allowable Cantilever _,i_____ Landscape s _— 23" `___ _____NA_____ Standoff Configuration Landscape Staggered Max Standoff Tributary Area _ Trib __ ' _ __a _ 17 sf - - _ __ PV Assembly Dead Load �_` __ W-PV 3 psf _ Net Wind Uplift at Standoff T_actual_-____ �__X465 lbs �_ ___ - _ _____ Uplift Capacity of Standoff -- T-allow _ _ _ _ 500_lbs ___Tv__. R Standoff Demand/Capacity ' DCR— 93.0% X-Direction Y-Direction Max Allowable Standoff Spacing _`__ Portrait __ ` 32"_ _ _ 65" _ Max Allowable Cantilever __________i Portrait __p,__` 14" NA _ Standoff Configuration Portrait Staggered Max Standoff Tributary_Area __ __ Trib __�__ 14 sf __ PV_Assem_bly Dead Load W-PV _ 3 psf Net Wind U _`plift at Standoff__ T-actual _- ___ ____ -388 lbs 7. -_-~� _ Uplift Capacity of Standoff _ T-allow_ _ 500 lbs _ _ Standoff Demand/Capacity DCR - - �- 77.5% - ---_ _____� {STRUCTURE ANALYSIS - (LOADING SUMMARY AND MEMBER CHECK -MP4 ms _ °, Member Properties Summary MP4 Horizontal Member Spans . • Rafter Properties Overhang 1.16 ft Actual W 1.50" Roof System Properties Span 1 12.83 ft Actual!) 9.25" Number of Spans(w/o Overhang) 1 Span 2 Nominal Yes Roofing Material Comp Roof Span 3 - A 13.88 in.^2 Number of Layers(Comp Only) ( 1 Layers) Span 4 Sx 21.39 in.^3 Re-Roof to 1 Layer of Comp? No Span 5 I,t 98.93 in.^4 Plywood Sheathing Yes Total Span 13.99 ft TL Defl'n Limit 180 Board Sheathing None PV 1 Start 1.83 ft Wood Species - SPF Vaulted Ceiling Yes PV 1 End 11.58 ft Wood Grade #2 Rafter Slope 43° PV 2 Start Fb 875 psi Rafter Spacing 16"O.C. PV 2 End FV 135 psi Top Lat Bracing Full PV 3 Start E 1400000 psi Bot Lat Bracing Full PV 3 End Emin 510000 psi Member Loading Summary. ° Roof Pitch . 11/12 •Initial Pitch Adjust 'Non-PV Areas PV Areas Roof Dead Load DL 13.5 psf x 1.37 18.5 psf 18.5 psf PV Dead Load _ PV-DL 3.0 psf x 1.37 4.1 psf Roof Live Load RLL 20.0 psf x 0.65 13.0 psf Live/Snow Load LL/SL1'2 20.0 psf x 0.48 I x 0.3 - 9.6 psf 6.0 psf Total Load TL ` 31.5 psf ° 28.6 psf Notes: 1. ps=Cs*pf;Cs-roof,Cs-pv per ASCE 7[Figure 7-2] 2. pf=0.7(Ce)(Cr)(Is)p9; Ce=Ct=Is=1.0; Member Design Summary(per NDS) . , - Governing Load Comb CD, CL(+) - CL(-)` CF ' - Cr D+S • • 1.15 1.00 1.00 ° 1.1 . 1.15 Member Analysis Results Summary - • Maximum Max Demand @ Location Capacity - DCR Shear Stress 28 psi 1.2 ft. 155 psi 0.18 Bending(-i-)Stress 435 psi 7:7 ft. 1273 psi 0.34 (Governs) Bending(-)Stress -16 psi 1.2 ft. -1273 psi 0.01 Total Load Deflection 0.17 in. 7.6 ft. L/931 0.19 CALCULATION OF_DESIGN_WIND-LOADS----11P4–---__-_- -___--1—___—____—_—_____—____—________-_- ----- _---1 Mounting Plane Information Roofing_Material Comp Roof - --- -- - --- ----- -- ---- - ----- ----------- -------- --- ------- PVSystem Type __ _ - _--__ _ SolarCity SleekMountTM SpanningVentsNo ___ Standoff(Attachment Hardware) Comp Mount Type C------------ Roof Slope -- 43°- -------- Rafter Spacing_ -- - - - 16"O.C. _ _ _ Framing Type/Direction Y-Y Rafters PurlinSpacing X-XPurlins Only_ _ NA ' --- - -- -- --- --- - - - Tile Reveal Tile Roofs Only NA Tile Attachment System Tile Roofs Only_ _ NA _____ Standing Seam Spacing SM Seam Only NA Wind Design Criteria Wind Design Code ASCE 7-05 Wind Design Method Partially/Fully Enclosed Method Basic Wind Speed V 120 mph Fig. 6-1 Exposure Category C Section 6.5.6.3 _ Roof Style Gable/Hip Roof Fig.6-11B/C/D-14A/B Mean Roof Height h 25 ft Section 6.2 Wind Pressure Calculation Coefficients Wind Pressure Exposure KZ 0.95 Table 6-3 ------------- ---- - --- --- ----- ---- -- ----- - ---- -- --- ------- - ------------- - ----------- Topographic Factor KA 1.00 _ Section 6.5.7_ Wind Directionality Factor Kd 0.85 Table 6-4 Importance Factor I 1.0 Table 6-1 Velocity Pressure qh qh =0.00256(Kz)(Kzt)(Kd)(V^2)(I) Equation 6-15 29.6 psf Wind Pressure Ext. Pressure Coefficient(Up) GC,„(uo) -0.95 Fig.6-11B/C/D-14A/B Ext. Pressure Coefficient(Down) GCo(Down) 0.88 Fig.6-11B/C/D-14A/B Design Wind Pressure p p=qh(GC,) Equation 6-22 Wind Pressure Up p(„p) -28.2 psf Wind Pressure Down P(down) 25.9 psf ,ALLOWABLE STANDOFF SPACINGS X-Direction Y-Direction Max Allowable Standoff Spacing -_ Landscape 64" 39" _ Max-Allowable Cantilever _ _ - --- -- -_._____--_ -Landscape - - 23�� - -- - - - NA - Standoff Configuration Landscape Staggered Max Standoff Tributary Area ______-__ _-__ Trib _ 17 sf ---- -- - - - ----- -------- - ---- -- -- - - -- --- ---- - - PV Assembly Dead Load W-PV 3 psf —-- - - ---- -- ------ ---- - ----- - --- - - --- ---- - - ---------- -- -- - Net Wind Uplift at Standoff T-actual -465 lbs ________________ _ __ - __ Uplift Capacity of Standoff T-allow _500 lbs _ -------- ----------------------- - _____-_ - - ------- - - - Standoff Demand/Capacity DCR - 93.0% X-Direction Y-Direction Max Allowable Standoff Spacing Portrait 32" 65" _ Max Allowable Cantilever__ Portrait _ .14" --- Standoff Configuration Portrait Staggered - - Max StandoffTributary_Area - _ _ Trib _-_ PV Assembly Dead Load -- W-PV 3 psf - - ------ - ------ -- - --- - — --- - -------------- --- - Net Wind Uplift atStandoff __ ___ _ Tactual _ _ -388113s - - --- --- ------- ------- ----- Uplift Capacity of Standoff _T-allow_ 500 lbs Standoff Demand/Capacity DCR 77.5% .-- <, ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES - A AMPERE 1. WHERE ALL TERMINALS OF THE DISCONNECTING AC ALTERNATING CURRENT MEANS MAY BE ENERGIZED IN THE OPEN POSITION, BLDG BUILDING A SIGN WILL BE PROVIDED WARNING OF THE 0 _� CONC CONCRETE HAZARDS PER ART. 690.17. DC DIRECT CURRENT 2. EACH UNGROUNDED CONDUCTOR OF THE EGC EQUIPMENT GROUNDING CONDUCTOR MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY , (E) EXISTING PHASE AND SYSTEM PER ART. 210.5. N) EMT ELECTRICAL METALLIC TUBING 3. A NATIONALLY—RECOGNIZED TESTING - GALV GALVANIZED LABORATORY SHALL LIST ALL EQUIPMENT IN C� GEC GROUNDING ELECTRODE CONDUCTOR COMPLIANCE WITH ART. 110.3. GND GROUND 4. CIRCUITS OVER 250V TO GROUND SHALL HDG HOT DIPPED GALVANIZED COMPLY WITH ART. 250.97, 250.92(B) -16, — I CURRENT 5. DC CONDUCTORS EITHER DO NOT ENTER Imp CURRENT AT MAX POWER BUILDING OR ARE RUN IN METALLIC RACEWAYS OR Isc SHORT CIRCUIT CURRENT ENCLOSURES TO THE FIRST ACCESSIBLE DC kVA KILOVOLT AMPERE DISCONNECTING MEANS PER ART. 690.31(E). kW KILOWATT 6. ALL WIRES SHALL BE PROVIDED WITH STRAIN LBW LOAD BEARING WALL RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY MIN MINIMUM UL LISTING. (N) NEW 7. MODULE FRAMES SHALL BE GROUNDED AT THE NEUT NEUTRAL UL—LISTED LOCATION PROVIDED BY THE NTS NOT TO SCALE MANUFACTURER USING UL LISTED GROUNDING OC ON CENTER HARDWARE. PL PROPERTY LINE 8. MODULE FRAMES, RAIL, AND POSTS SHALL BE POI POINT OF INTERCONNECTION BONDED WITH EQUIPMENT GROUND CONDUCTORS AND PV PHOTOVOLTAIC GROUNDED AT THE MAIN ELECTRIC PANEL. SCH SCHEDULE 9. THE DC GROUNDING ELECTRODE CONDUCTOR SS STAINLESS STEEL SHALL BE SIZED ACCORDING TO ART. 250.166(B) & • STC STANDARD TESTING CONDITIONS 690.47. TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY ' V VOLT Vmp VOLTAGE AT MAX POWER Voc VOLTAGE AT OPEN CIRCUIT VICINITY MAP INDEX W WATT 3R NEMA 3R, RAINTIGHT Cr u �_ i._ •- /E ° '."*s .• • PV1 COVER SHEET PV2 SITE PLAN I PV3 STRUCTURAL VIEWS - ; M1 " , ' '° , PV4 UPLIFT CALCULATIONS f \ '' PV5 THREE LINE DIAGRAM LICENSE GENERAL NOTES Q • Cutsheets Attached I f' � yc yr 4M1�h � � � �k� �� 1. THIS SYSTEM IS GRID—INTERTIED VIA A Iy y(i" , k ' UL—LISTED POWER—CONDITIONING INVERTER. • • • }. r N. 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. v If °{ 3. SOLAR MOUNTING FRAMES ARE TO BE • ' _ GROUNDED. 4. ALL WORK SHALL COMPLY WITH THE 2010 - - ° '"' a , , _ - , MODULE GROUNDING METHOD: ZEP SOLAR R.C.N.Y.S. ,,� , 5. ALL ELECTRICAL WORK SHALL COMPLY WITH '- }= ' 'F.IREV BY DATE COMMENTS AHJ: Southold Town %.,", r THE 2008 NATIONAL ELECTRIC CODE. ,;" 2 -14 RE‘, ‘ DATE COMMENTS l i,3 * UTILITY: Long Island Power Authority (LIPA) f'Y'` _ . ©©• © 4 a Llv AI aal lobe, New Ydek GIS,, USDA Farm ervic=e A'g n ,©©© ** _ JB-1 1917 9 0 0 PREMISE OWNER: DESCRIPTION: DESIGN: CONFIDENTIAL—THE INFORMATION HEREIN JOB NUMBER40'6 CONTAINED SHALL NOT BE USED FOR THE KRUPSKI, EUGENE KRUPSKI RESIDENCE Jeff Bunca �_ , BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM:110R s NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 2230 SOUNDVIEW AVE 14 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES: MATTITUCK NY 11952 3055 Clearview Way THE SALE AND USE OF THE RESPECTIVE (56) YINGLI # YL250P-29b SOLARCITY EQUIPMENT,WITHOUT THE WRITTEN PAGE NAME SHE T: REV: DATE San Mateo,CA 94402 PERMISSION OF SOLARg1Y INC. ���' T:(650)638-1028 F:(650)638-1029 SOLAREDGE ;SE6000A—US—ZB—U 6312987688 COVER SHEET PV 1 6/25/2014 (888)—SOL—CITY(765-2489)www.solarcity.com • • PITCH:43 ARRAY PITCH:43 O MP1 AZIMUTH:220 ARRAY AZIMUTH:220 I MATERIAL:Comp Shingle STORY: 2 Stories PITCH: 35 ARRAY PITCH:35 W MP2 AZIMUTH:130 ARRAY AZIMUTH:130 �' MATERIAL:Comp Shingle STORY: 2 Stories (E)DRIVEWAY PITCH:43 ARRAY PITCH:43 :E i MP3 AZIMUTH:220 ARRAY AZIMUTH:220 1 1 _ MATERIAL:Comp Shingle STORY: 2 Stories I9 1 PITCH:43 ARRAY PITCH:43 0E5-1 ® ® CP _ _, t ' e MP4 AZIMUTH:220 ARRAY AZIMUTH:220 "" fit + ' MATERIAL:Comp Shingle STORY: 2 Stories , , A, 1$ rj_r"(� PITCH:43 ARRAY PITCH:43 62 ` 1 MP5 AZIMUTH:130 ARRAY AZIMUTH:130 w ' " MATERIAL:Comp Shingle STORY: 2 Stories r" k't PITCH:43 ARRAY PITCH:43 / \ / \ rr � ' MP6 AZIMUTH:220 ARRAY AZIMUTH:220 '���' ,' ° ° ° ° ° ° ° ,tea.+ 1 I% D,q D1 I �.`, air{ MATERIAL:Comp Shingle STORY: 2 Stories 0 0 0 e a ° �— IttQ y -.- 9:V r e e °- e• 0 0 0 #4 `9®*12/6 `4 i f �e o o o o o47��'se/ �r ,t MPS ° . ° . LEGEND ° ° 0 Amir Massoumi 0 o ° MY 2014.06.26 10:44:24 -07'00' 0 (E) UTILITY METER & WARNING LABEL 0 0 0 ® INVERTER W/ INTEGRATED DC DISCO 5 & WARNING LABELS 4. N Do DC DISCONNECT & WARNING LABELS O " 0 ® AC DISCONNECT & WARNING LABELS no 0 c o .:I e ® ° fl3 Mh 8 8 Q DC JUNCTION/COMBINER BOX & LABELS 0 i — = Q DISTRIBUTION PANEL & LABELS LG LOAD CENTER & WARNING LABELS ,3 MP6 IO DEDICATED PV SYSTEM METER Q STANDOFF LOCATIONS ' 0 0 0 ' ° CONDUIT RUN ON EXTERIOR MP4 --=, CONDUIT RUN ON INTERIOR - GATE/FENCE 0 0 ° 0 HEAT PRODUCING VENTS ARE RED .346 4 0 ° ' i INTERIOR EQUIPMENT IS DASHED IO! L=J E SITE PLAN Scale:1/16" = 1' 01' 16' 32' . , ` 5 ■.—; CONFIDENTIAL—THE INFORMATION HEREIN JOB NUMBER: JB-119179 0 0 PREMISE OWNER: DESCRIPTOR: EUGENE KRUPSKI RESIDENCEDESCRIPTOR:noN: DESIGN: ViSolarCity,CONTAINED SHALL NOT BE USED FOR THEJeff Bunco BENEFIT OF ANYONE EXCEPT SOLARGTY INC., MOUNTING SYSTEM: NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 2230 SOUNDVIEW AVE 14 KW PV ARRAY 1` PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES: MATTITUCK, NY 11952 ORGANIZATION, EXCEPT IN CONNECTION YA1H 3055 CleaMew Way THE SALE AND USE OF THE RESPECTIVE (56) YINGLI # YL25OP-29b g1�7 �y ppTE San Mateo,CA 94402 SOLARGIY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME T:(650)638-1028 F:(650)638-1029 PERMISSION OF SOLARCITY INC. /ER' SOLAREDGE #SE6000A-US-ZB-U 6312987688 SITE PLAN PV 2 6/25/2014 (Sea)-SOL-aTY(765-2489)www.soIarcity.aam Ak , / lit (E) 2x6 / 1 0 / . II 1 , k , ° ,,,,-. 0 es" 0 ..431. 0 moutez_ko . 4," 4 # � i r `'r �, r, I, .-2" 7'-4" 0 �II i! r _ d J , h � (E) LBW % ' ` +. Z 17'-10" at v—,1 (E) LBW (E) LBW O SIDE VIEW OF MP1 NTS �� 0ar6 � x,66 ' SIDE VIEW OF MP2 NTS O MP1 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES 0 $SIOSP4 LANDSCAPE 64" 23" STAGGERED MP2 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES PORTRAIT 32" 14" LANDSCAPE 64" 23" STAGGERED ROOF AZI 220 PITCH 43 PORTRAIT 32" 14" RAFTER 2x10 @ 16"OC ARRAY AZI 220 PITCH 43 STORIES:2 ROOF AZI 130 PITCH 35 CJ. 2x10 @16"OC Comp Shingle RAFTER 2x10 @ 16"OC ARRAY AZI 130 PITCH 35 STORIES.2 CJ. 2x10 @16"OC l Comp Shingle PV MODULE • * 5/16" BOLT WITH LOCK INSTALLATION' ORDER & FENDER WASHERS LOCATE RAFTER, MARK HOLE ZEP LEVELING FOOT (1) LOCATION, AND DRILL PILOT / 7 ZEP ARRAY SKIRT (6) HOLE. SEAL PILOT HOLE WITH �� (4) (2) POLYURETHANE SEALANT. " ZEP COMP MOUNT C4111V�� Oc ZEP FLASHING C `4_d� _a„.._ (3) INSERT FLASHING. (E) COMP. SHINGLE �z s><. —r_:>L. MEE MEM (4) PLACE MOUNT. (E) ROOF DECKING `� 10,-9" (5) INSTALL LAG BOLT WITH 5/16" DIA LAG BOLT (5) SEALING WASHER. (E) LBW WITH SEALING WASHER LOWEST MODULE SUBSEQUENT MODULES i INSTALL LEVELING FOOT WITH 43p SIDE VIEW OF MP3 NTS 6) (2-1/2" EMBED, MIN) ( BOLT & WASHERS. (E) RAFTER MP3 X-SPACING X-C N ILEVER Y-SPACING Y-CANTILEVER NOTES 1 STAN DOFF LANDSCAPE 64" 23" STAGGERED S 1RAFTER 2x10 @ 16"OC PORTRAIT 32" 141' 43 STORIES. 2 Scale: 1 1/2" = 1' ROOFRAa 220 PITCH 43 CJ. None @16"OC Comp Shingle J B-11917 9 00 PREMISE ONNER: DESCRIPTION: DESIGN: CONFIDENTIAL- THE INFORMATION USED RHTHE JOB NUMBER: SolarCity CONTAINED SHALL NOT BE USED FOR THE KRUPSKI, EUGENE KRUPSKI RESIDENCE Jeff Bunco ���`a BENEFIT OF ANYONE EXCEPT SOLARCITY INC.. MOUNTING SYSTEM: �i NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 2230 SOUNDVIEW AVE 14 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENT'S MooulEs MATTITUCK, NY 11952 ORGANIZATION, EXCEPT IN CONNECTION WITH3055 Clearvlew Way THE SALE AND USE OF THE RESPECTIVE (56) YINGLI # YL250P-29bPAGE NAME: SHEET: REV DATE: San Mateo,CA 94402 SOLARCITY EQUIPMENT. WITHOUT THE WRITIEN INVERTER: T:(650)638-1028 F(650)638-1029 PERMISSION OF SOLARCITY INC. SOLAREDGE #SE6000A—US—ZB—U 6312987688 STRUCTURAL VIEWS PV 3 6/25/2014 (888)-SOL-CITY(765-2489)www.solarcIty.com r, 1 i. li 'kI s o . -Nor l ...,+06, ,„ off,;r. * `ti r `P. e r ,.�`• . .*'.4 0 1.4114 X 1 fli �r ice. t % . os 081626 .• , l eibPessrootaN:t4:`'' PV MODULE (E) 2x6 5/16" BOLT WITH LOCK INSTALLATION ORDERidid & FENDER WASHERS `� LOCATE RAFTER, MARK HOLE ZEP LEVELING FOOT (1) LOCATION, AND DRILL PILOT ZEP ARRAY SKIRT (6) HOLE. (4) (2) SEAL PILOT HOLE WITH ZEP COMP MOUNT Carimi POLYURETHANE SEALANT. ZEP FLASHING C `,��r�� ��5: (3) INSERT FLASHING. /\ (E) COMP. SHINGLE !�;� ;� E.)- PLACE MOUNT. ��� (E) ROOF DECKING VIM IIIIIIAijl11.' O INSTALL LAG BOLT WITH 5/16" DIA LAG BOLT (5) SEALING WASHER. _ '2 12'-10" WITH SEALING WASHER LOWEST MODULE SUBSEQUENT MODULES INSTALL LEVELING FOOT WITH (E) LBW (2-1/2" EMBED, MIN) (6) BOLT & WASHERS. SIDE VIEW OF MP4 rrrs (E) RAFTER O STANDOFFMP4 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES LANDSCAPE Scale: 1 1/2'= 1' PORTRAITSTAGGERED 32" 14" RAFTER 2x10 @ 16"OC ROOF AZI 220 PITCH 43 STORIES:2 ARRAY AZI 220 PITCH 43 C.]. 2x10 @16"OC Comp Shingle CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: J B-119179 00 PREMISE OWNER: DESCRIPTION: 1 DESIGN: r,` CONTAINED SHALL NOT BE USED FOR THE KRUPSKI, EUGENE KRUPSKI RESIDENCE Jeff Bunco _ BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM2230 SOUNDVIEW AVE 14 KW PV ARRAY SYSTEM: 2230 NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES MATTITUCK, NY 11952 ORGANIZATION, EXCEPT IN CONNECTION WITH3055 CleaMew Way THE SALE AND USE OF THE RESPECTIVE (56) YINGLI # YL25OP-29bSan Mateo,CA 94402 SOLARCITY EQUIPMENT, WITHOUT THE WRITTENINVERTER: PAGE NAME' DAIS T:(650)638-1028 F:(650)638-1029 PERMISSION OF SOLARCITY INC. SOLAREDGE #SE60O0A—US—ZB—U 6312987688 STRUCTURAL VIEWS PV 3 6/25/2014 (888)-SOL-an(765-2489)www.solaralty.com UPLIFT CALCULATIONS SEE SEPARATE PACKET FOR STRUCTURAL CALCULATIONS. CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: J B-119179 00 PREMISE OMS DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE KRUPSKI, EUGENE KRUPSKI RESIDENCE Jeff Bunco e,SoIarCity BENEFIT OF ANYONE EXCEPT SOLARCITY INC.. MOUNTING SYSTEM: NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 2230 SOUNDVIEW AVE 14 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES: M ATTI TU CK N Y 119 52 ORGANIZATION, EXCEPT IN CONNEC110N WITH3055 Clearview Way THE SALE AND USE OF THE RESPECTIVE (56) YINGLI # YL25OP-29b SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN iNVER7ER: PAGE NAME SHEET: REk DATE Son 638-1028 F:(650)94402 PERMISSION OF MENT.SOLARCITY INC. T:(650) 638-1029 SOLAREDGE #SE6000A—US—ZB—U 6312987688 UPLIFT CALCULATIONS PV 4 6/25/2014 (888)—SOL—CITY(765-2489)www.salarcity.com • GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND (N) #8 GEC TO (N) GROUND ROD Panel Number:Siemens Inv 1: DC Ungrounded INV 1 -(1)SOLAREDGE 'a 6000A-US-ZB-U EL; q -(56)YINGLI # YL25OP-29b AT PANEL WITH IRREVERSIBLE CRIMP Meter Number.099054493 Inv 2: DC Ungrounded Inverter, 61.6w,240V/208V, 97.5%/97%; w/Unifed Disco and ZB, AFI PV Module; 250W, 226.2W PTC, H4, 40mm, YGE-Z 60, Black Frame, ZEP Enabled Underground Service Entrance Tie-In: Supply Side Connection INV 2-(1)SOLAREDGE 41 6000A-11s-Z0-0 IABEL B Inverter, 61 1'W, 240V/208V, 97.5$ 97%; w/Unifed Disco and ZB, AFC' Voc: 37.6 Vpmax: 29.8 INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER E 150A MAIN SERVICE PANEL SolarCity E 150A/2P MAIN CIRCUIT BREAKER Inverter 1 (E) WIRING CUTLER-HAMMER BRYANT Disconnect (N) 125A Load Center i2 11 Q SOLAREDGE II 6 A • TDC+ (+ B 70A D SE6000A-US-ZB-U • E C 1 String(s)Of 14 On MP SE , 35A/2P ® t- _ _ J r A A tin A - •�• '1 " �. , T v 150A/2P B ---.......F -, • • L2 �_ •� DC+ CO �L�} N =L•� Dc I5 TDC+(E) LOADSND _ - EGG .�DC+ - tt-, o r-- GEC N �_ DC- . DC- -,-. G 1 Stnng(s)Of 140n MP 1 03 = I GND I----EGC--- 1 _ EGC fPwj-li • • r----J I +._w��J rz--- v V (1)Conduit Kit; 3/4" PVC, Sch. 40 N I I Inverter 2 1 - 10 SOLAREDGE 8 A 3 Dc+ _ T� Z-Z I 1Stnng(s)Of14OnMP : ,I, oV I SE6000A-US-ZB-U DC- I CD • I i 35A/2P ® r _ __ EGC J - T GECl/ �.�._. v TO 120/HAS i --r,--'' - N _~ L DC- i (4� SINGLE PHASE __ ]� UTILITY SERVICE L_s,s� EGG __ •�DC+ CI • oc+ GEC T N _#_ DG -- I DG 1 Stnng(s)Of 14 On MP 3& I. GND I____EGC- 1--�'---1 EGC J V (1)Conduit Kit; 3/4" PVC,Sch. 40 EGC ON ROOF TO BE ROUTED WHERE NOT SUBJECT TO PHYSICAL DAMAGE. WHEN ROUTED SUBJECT TO PHYSICAL . DAMAGE THE SIZE MUST BE INCREASED TO #6 SOLID BARE COPPER. • Voc* = MAX VOC AT MIN TEMP POI-(1)Ground Rod; 5/0-2/0 8' x 8', Copper B (1)CUTLER-HAMMER#DG223NRB /� A -(2)SolorCitY#4 STRING JUNCTION BOX DC - 2)ILSCO/IPC 4/ Disconnect; 100A, 240Vac, Fusible, NEMA 3R /"� 2x2 STRINGS, UNFUSED, GROUNDED Insulation Piercing Connector, Main 4/0-2, Tap 2/0-6 -(1)CUTLER- AMMER DGIOONB -(2)ZEP#850-1196-002 (1)BRYANT BR816L125RP Ground/Neutral Kit; 60-100A, General Duty(DG) Universal Box Bracket [PKG B] D # -(1)CUTLER-HAMMER#DS16F1( \, Load Center, 125A, 120/240V, NEMA 3R Oass R Fuse Kit PV 1- )SPowerEBDox Optimizer,300W,H4,DC to DC, ZEP -(2)CUTLER-HAMMER (2)u n.ER r,HANAERP#2 S aces -(2)FERRAZ SHAWMUTT 4 TR7OR PV BACKFEED OCPB P Fuse; 70A, 250V, Class RK5 SSC-SUPPLY SIDE CONNECTION. DISCONNECTING MEANS SHALL BE SUITABLE AS SERVICE EQUIPMENT AND SHALL BE RATED PER NEC. -- © (I(I)AWG#4, THWN-2, Black (1)AWG#8, THWN-2, Black (1)AWG 110, 11 -2,Black Voc* =500 VDC Isc =15 ADC (2)AWG#10, PV WIRE,Black Voc* =500 VDC Isc =15 ADC §-(1)AWG#4,THWN-2, Red O RE(1)AWG#8, THWN-2, Red O §-(1)AWG#10, THWN-2,Red Vmp =350 VDC Imp=9.87 ADC O (1)AWG#6, Solid Bare Copper EGC Vmp =350 VDC Imp=9.87 ADC (1)AWG#4,THWN-2, White NEUTRAL Vmp =240 VAC Imp=50 MC 666666 (1)AWG#10,THWN-2, White NEUTRAL Vmp =240 VAC Imp=25 AAC (1 AWG 110, THWN-2,Green EGC _ . -.(1)AWG#4, THWN-2, Green EGC/GEC-(1)Conduit Kit; 3/4' EMT -(1)AWG#8, THWN-2,Green EGC/GEC-(1)Conduit Kit; 3/4"EMT II (1 AWG#10, THWN2 Black Voc* =500 VDC Isc =15 • ADC (2)AWG#10,PV WIRE, Black Voc* =500 VDC Isc =15 ADC ®6 (1)AWG#4, THWN-2, Black (1)AWG#8, THWN-2,Black ©li �(1)AWG#10,THWN-2 Red Vmp =350 VDC Imp=9.87 ADC O (1)AWG#6, Solid Bare Copper EGC Vmp =350 VDC Imp=9.87 ADC �(1)AWG#4, THWN-2, Red ®�(1)AWG#8, 1HWN-2,Red 666666 (1)AWG#10, THWN-2, Green EGC . 6 (1)AWG 14, THWN-2, White NEUTRAL Vmp =240 VAC Imp=50 AAC II/��ELLL(1)AWG#10, THWN-2, White NEUTRAL Vmp =240 VAC Imp=25 AAC (1)AWG 110, THWN-2, Black Voc* =500 VDC Isc =15 ADC -(2)AWG#10, PV WIRE,Black Voc* =500 VDC Isc =15 ADC -,(1)AWG#4,,Solid Bare,Copper GEC. -(1)Conduit Kit; 3/4'EMT, _ . . (1)AWG#8. THWN-2, Green EGC/GEC-(1)Conduit Kit; 3/4"EMT , _ .. O -(1)AWG#10, THWN-2,Red Vmp =350 VDC Imp=9.87 ADC O cc"-(1)AWG#6, Solid Bare Copper EGC Vmp =350 VDC Imp=9.87 ADC (1)AWG#10, THWN-2,Green EGC _ . .. (1)AWG#10, THWN-2,Black Voc* 500 VDC Isc =15 ADC -(2)AWG#10, PV WIRE,Black Voc* =500 VDC Isc =15 ADC ® (1)AWG 110, THWN-2,Red Vmp =350 VDC Imp=9.87 ADC ® -(1)AWG#6, Solid Bare Copper EGC Vmp =350 VDC Imp=9.87 ADC (1)AWG#10. THWN-2. Green FGC J B-11917 9 00 PREMISE OWNER: DESCRIPTION: . DESIGN: CONFIDENTIALIED - THE INFORMATION USHEREIN JOB NUMBER �,�SolarCity CONTAINED SHALL NOT BE USED FOR THE KRUPSKI, EUGENE KRUPSKI RESIDENCE Jeff Bunco �. BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: �..� NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type.0 2230 SOUNDVIEW AVE 14 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENYS ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES: M ATTI TU C K, NY 11952 THE SALE AND USE THE RESPECTIVE (56) YINGLI # YL250P-29b 3055 Clearview Way PAGE NAME SHEET: REV. DATE San Mateo,CA 94402 SOLARCITY EQUIPMENTT,. WITHOUT THE WRITTEN INVERTER: T:(650)638-1028 F.(650)638-1029 PERMISSION OF sOLARaTY INC. SOLAREDGE SE6000A-US-z8-U 6312987688 THREE LINE DIAGRAM PV 5 6/25/2014 (888)-SOL-an (765-2489)www.soaralty.com • SolarCity SleekMountT"" - Comp ? SolarCity SleekMountT_M - Comp The SolarCity SleekMount hardware solution •Utilizes Zep Solar hardware and UL 1703 listed --- `` Installation Instructions is optimized to achieve superior strength and Zep CompatibleTM modules aesthetics while minimizing roof disruption and o Interlock and grounding devices in system UL c� s, s . C) Drill Pilot Hole of Proper Diameter for labor.The elimination of visible rail ends and listed to UL 2703 N o Fastener Size Per NDS Section 1.1.3.2 mounting clamps,combined with the addition „ o Seal pilot hole with roofing sealant of array trim and a lower profile all contribute •Interlock and Ground Zep ETL listed to UL 1703 p, V. to a more visually appealing system.SleekMount as"Grounding and Bonding System” '0\ A:"• � 0 Insert Comp Mount flashing under upper utilizes Zep CompatibleTM modules with •Ground Zep UL and ETL listed to UL 467 as v--- layer__� layer of shingle strengthened frames that attach directly to grounding device ® Place Comp Mount centered Zep Solar standoffs,effectively eliminating the - -- --- -----_._. ®Paintedgalvanized waterproof flashingupon flashing need for rail and reducing the number of p j E{ standoffs required. In addition, composition •Anodized components for corrosion resistance f �5 Install lag pursuant to NDS Section 11.1.3 shingles are not required to be cut for this I I with sealing washer. system,allowing for minimal roof disturbance. •Applicable for vent spanning functions 0 Secure Leveling Foot to the Comp Mount i--" i # using machine Screw �° '— i ® Place module il `` Components _..___,�--- . -___--- � ._ 5/16"Machine Screw ` L,4 0 Leveling Foot C` Lag Screw - , ®yp 9 {p Comp Mount R,'-----, r�'~"'�_ Comp Mount Flashing ' o a® n- ® off ,sm.", Qconvar4B 4v®B,- • ®®®,�olal°City® N N "/. g co LISTED P" SolarCity© January Janua 2013 m 2013 4 cc solar - • • ! SolarEdge Power Optimizer IN.I Module Add-On for North America — P300 / P350 / P400 SolarEdge Power Optimizer P300 P350 P400 t • Module Add-On For North America (� (forodulesPV (for72-cell PV (for 96-cell PV 1 modules) modules) modules) P300 / P350 / P400 CL INPUT -- O Rated Input DC Poweri'i 300 350 400 W Absolute Maximum Input Voltage(Voc at lowest temperature) 48 60 80 Vdc } MPPT Operating Range 8-48 8-60 8-80 Vdc ° - M Maximum Short Circuit Current(Inc) 10 - Adc - 1••`' Maximum DC Input Current 12 5 s Adc - - w Maximum Efficiency 99 5 % - _Weighted Efficiency 98 B - - -1 % Overvoltage Category I II _ OUTPUT DURING OPERATION(POWER OPTIMIZER CONNECTED TO OPERATING INVERTER) O Maximum Output Current 15 Adc , Maximum Output Voltage 60 Vdc__ - CL OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF) x - X.- - Safety Output Voltage per Power Optimizer —1 1 --FTdc .NO' ivcar` t `STANDARD COMPLIANCE--__ _ — __ _ -- ^-------_^— _` 4 1 EMC _ FCC Part15 Class B,IEC61000-6-2,IEC61000-6-3 _ + ' ' - r 1.. a�y' '°" 11�$ SafetyIEC62309-1(class II safety),UL1741 RoHS _Yes _, _ - '`� 'INSTALLATION SPECIFICATIONS ___ _ - vMaximum Allowed System Voltage 1000Vdc Dimensions(W x L x H) 1410212 x405/555x 8340159 j mm/in Welght(including cables) _ 950/21 s gr/Ib kr Input Connector MC4/Amphenol/Tyco _Output Wire Type/Connector Double Insulated,Amphenol - Output Wire Length 095/30 1 - 12/39 m/ft Operating Temperature Range -40-+85/-40-+185 - `e Protection Rating I IP65/NEMA4 - Relative Humidity I 0-100 % of Rated STC power or the rmdule Module of up to•594 power tolerance allowed. I PV SYSTEM DESIGN USING A SOLAREDGE THREE PHASE THREE PHASE' t1 + SINGLE PHASE • 1 ,INVERTER — — 208V 480V PV power optimization at the module-level. - Minimum String Length(Power Optimizers) 81 10 18 ` — Up to 25%more energy - Maximum Stnng Length(Power Optimizers) 25 25 50 + Maximum Power per String 5250 6000 12750 W Superior efficiency(99 5%) Parallel Strings of Different Lengths or Onentations Yes • i .. Mitigates all types of module mismatch losses,from manufacturing tolerance to partial shading - I - - - -- — Flexible system design for maximum space utilization — Fastmstallationwithasinglebolt 1 -�_-_� ___.- -__ __ _ _-_�.___-_..____- _�-- .._._._- __-___.___ .__ _ �-___ __ _ _ __ — Next generation maintenance with module-level monitoring _ ,. I — Module-level voltage shutdown for installer and firefighter safety i -- _ .i CE r USA - GERMANY - ITALY - FRANCE - JAPAN - CHINA - ISRAEL - AUSTRALIA www solaredge us i ..,..1,...,re -zMw„ - „ • SD-. i,•.a>ru7 se,sr.vr-41 - .iS, +'i 51— 1+ Wrka 4 Lr t+ �'.•'d -7:7-H. YGZ 60 YL255P-29b YGZ 60 CELL SERIES Powered by YINGLI YL250P-296 YINGL-I ;r.�O�.AI� CELL SERIESNIK YL245P-29b ELECTRICAL PERFORMANCE YL240P-29b U.S.Soccer Powered by Yingli Solar Electrical parameters at Standard Test Conditions(STC) GENERAL CHARACTERISTICS Module type YL260P-29b C YL255P-29b„YL250P-29b t YL245P-29b I YL240P-29b Dimensions(L/W/H) 6496n(1650mm)/3898in(990mm)/ Power output P . W 260 255 250 245 240 1.5Tin(40r"s") Power output tolerances „AP,... % _ -0/+3 Weight 4341bs(197kg) YINGLI SOLAR Z SERIES Ideal for residential Module efficiency y qm % 159 156 153 iso 147 ` - _.__ — V 29 8 and commercial applications where cost savings, Vnhage at lime V „ 303 300 839 4 296 29.3 Current atP t I,, A 8 5 Bag 839 8.28 8.18 PACKAGING SPECIFICATIONS installation time, and aesthetics matter most. _ Open.s,rcu,t voltage ii.V.. V 37.7 37.7 376 1 375 37.5 Number of modules per pallet „• 26 Short-circuit current „ Ir A 9 09 9 01 8.92 8.83 8 75 Number of pallets per 40'container' 28 STC 1000W/m'irradiance,25°C cell temperature,AM1 5g spectrum according to EN 60904-3 - Best Co)C^e fOr INIALLrE RS - ) Average relative efficiency reduction of 33%at 200W/m'according to EN 60904.1 Packaging box dimensions 67.3%1(1710nn,)/45.67m 1116Ornm)/ s;;, .— (L/W/H) 46.38in(1178m) (.Lower balance-of-system costs with Zep - Electrical parameters at Nominal Operating Cell Temperature(NOCT) Box weight 12021bs(545kg) Compatible'frame - - f c Z Power output P.,.,„ W 189.7 186 0 ! 182 4 tie 7 os t:. c Reduce on-roof labor costs by more than Voltage at P ;Vivicvi v z76 27 a 27 z v o 26 B Units:inch(mm) o - v Current at P,... lmvv A 6 87 6 79 6 71 6 62 6 54 38 98 990 ZrJ�o. _ - ��'- _ Open-arcust voltage ,V« „ V 348 34g 347 346 346 = _ If 1 57(40) Leverage the built-in grounding system- ..--- Short-circuit current ' Iw A „ 7 35 7.28 + 7 21 ` $ immini 7.14 7 07_ _ if it's mounted,it's grounded / , NOCTopen-circuit module operation temperature at800W/m'irradiance,20°Cambient temperature.irn/swind speed P 11.. Is Decrease your parts count-eliminate screws, - • -� M rails,mounting clips,and grounding hardware. THERMAL CHARACTERISTICS $ Nominal operating cell temperature;NOCf °C T__._.___ 46+/-2 -- -- Best Ch (j JOO' oice for M'EOO WINERS \\\ Temperature y c -0az Temperature coefficient of V. P., %P 9W°C -0 32 I v 0.Minimize roof penetrations while maintaining - �-' ,Vie,,, Temperature coefficient of L, m %/°C 005 Grounding holes e® pera o 6-00 236(6) ^° the system's structural Integrity - ^ppMP4Tj� t, Temperature coefficient ofV,.,v ^9.,, %/°C -0.42 Invest in an attractive solar array that includes kr �n'.« — — --- a black frame,low mounting profile,and - • _ - t _- %” 'h OPERATING CONDITIONS aesthetic arrayskirt. --` e ; /'. '1 �� '6A w i""� Max system voltage 1000Voc Mounting holes ,. 9 CO�Pp�\ q —_-- - 4-0 2564 315(6 5e8) 0 Increase energy output with flexible module _ -"• Max saner fuse sting „ --� 15A .-', �r sem, - - „ _ layouts(portrait or landscape). Lest reverse current isn�— •� ,. _ ..-./ 9 Drainage holes P Trust in the reliability and theft-resistance of 8_012x5315(3.8) the Zep COmpatlble'"system. operating temperature range t -00 to 185°F(-40 to 85°C) ^si IM1 , ZEP COMPATIBLE FRAME Max static load 2400Pa / 3 94(100) ( ±T:ria."Lz...L.w,.it Max.hailstone impact(diameter/velocity) 25mm/23m/s '—__ Leadinglimitedpowerwarranty*ensures /�D47(1) \�\ AC SOLUTION OPTION / r1 \ 91 2%of rated power for 10 years,and 80 7% / �,�r� \ The YGE-Z Series is now available as of rated power for 25 years CONSTRUCTION MATERIALS / \ an Enphase Energized'"AC Solution. — — - Front cover(material/thickness) low-iron tempered glass/3 2mm I � This solution delivers optimum I SECTION C-C � - Cell(quantity/material/dimensions/ -i— 60/multivystalline silicon/ ----- I 10-year limited product Warranty number of besbars) 156mmx 156mm/2 ora \ / performance and integrated intelligence _ __ _ _ •enph The Enphase M215-Z Zep Compatible --_—__—_____ —aset �� Encapsulant(material) —v-- ethylene vinyl acetate(EVA) \ / ENERGIZED I \ 1 / z+seawser� t Micromverter Is designed to connect '1n compliance with our warranty terms and conditions { - s - Frame(material/color/edge sealing) anodized aluminum alloy/black/silicone or tape \n\_—_ i directly into the Z Series module groove,eliminating y Junction box(ingress protection rating) e1P65 Warning Read the Installation and User Manual,n its entirety the need for tools or fasteners-all with one easy step Cable(length/cross-sectional area) 1200mm/4mm' before handling,installing,and operating Yingli modules ; Cat Li ,At 13,!, , k..,',' - i L,M'-"'Ela iia R'I�,`Cs o LP .ANT "I +!=1 Connector(type/ingress protection rating) Amphenol H4/a1P67 -_.__. _ Our Partners —�� UL 1703 and ULC 1703,CEC,FSEC,ISO 9001 2008,ISO tia11t 14001 2004,BS OHSAS 18001 2007,SA8000 )l.A� _ Intelligent real-time --___—____ -_---__ — s . ��^ monitoring at the system - and module level with Ir If you buy from Yingli Amencas,Yingli Amends The specifications in this datasheet are not guaranteed and are subject to change without poor nonce .,_____ •«. COOS gS acts as the Importer and complies with all This datasheet complies with EN 50380 2003 requirements Enlighten applicable tariffs Customers can buy from Yingli LISTED ), Amenias with no worry that they will be liable for i ODD MODULE, any import tones ma i •- 4ti i Yingli Green Energy Americas,Inc. YIN G L I S O L A R.COM/U S I Yingli Solar 1 ti info@yingliamericas.com -/. /did Tel:+1 (888)686-8820 YINGLISOLAR.0OM/US 1 NYSE:YGE ®Y nglGreen Energy Holding Co Ltd I YGQ60CeI)Senes_US_201403_VOi �SYINGO LAR U.S Soccer Powered by Yola a • C/) , so I a r - • • -.- Single Phase Inverters for North America solar • • : 1,C --i: SE3000A-US/SE3800A-US/SE5000A-US/SE6000A-US/ SE7600A-US/SE10000A-US/SE11400A-US W I SE3000A-USI SE3800A-US I SE5000A-US I SE6000A-USI SE7600A-US SE10000A-US SE11400A-US OUTPUT SolarEdge Single Phase Inverters9980@208V Nominal AC Power Output 3000 3800 5000 6000 7600 11400 VA . ... .. - ... ... .. . - .. 10000 @240V ..... 5400 @ 208V 10800 @ 208V For North America w Max AC Power Output 3300 4150 6000 8350 12000 VA ... .- . . . .. .... . .... .. . . .. 5450.@240V. . . ... 8350 .. .. .... AC Output Voltage Mm-Nam:Max• - - V - _ V _ 183-208:229 Vac ... .... ... .. .- - .. - . . .. .. .. .-.. .... SE3000A-US/SE3800A-US/SE5000A-US/SE6000A-US/ • AC Output Voltage Mm-Nom-Max' V V V V V SE7600A-US/SE10000A-US/SE11400A-US Z ` 211-240-264 Vac _ "• "` MaxAC rConhnuou�s Output Current. . ....12 5... I 16 I 46@•240V(I�th•HI Zsuntry ttmg.32:60 1G0 42 @ 240V• f 47 5 AHz , Il 593 se _ _ 2 -. iO - - , -" [i�.,, Utility Monitoring, standigngL'' , ,- - -. ..GFDI ... .. . ......... ... .. . .... -.. _ ;,'- ,` _ Protection,Country Configurable Yes - ! I -'-" s�wertef•'''.., I. Thresholds r„ {'f 4.6 it" ,INPUT ' - - i x:'', , , - `"-" =,1:12 m Recommended Max.DC PoweP' m �s a'o Watronty; ;" .. . . .. .. .. ° .-.. . ... . ... soo .... 12 .. ... ... -- --- -'•' •��" - ed . , `,, - -- ','"*-!%,:fsli0h��,o;j„'''u ; Transformer less[Unground . .. . . ..... ... . . . . .7 Yes ..... . . . - .. . .. . 375 4750 6250 9500 400 . h.,,,,,„,,n f., ..Max Input Voltage.... .... ... .... 5 0 .. .. -.... . . Vdc - -- -- - - ..Nom DClnputVoltage,.-, . _ .• .• •• •_•, 325@208V/350@240V ••• •. •• _-... .Vdc.. ., .-. t . ,� r'r .4; Max.Input Current*** . . • 9 5•.. . . .13 .(.15 5 @ 240V ... 18. -. • .. . 23•• 305 @?240V �.. _34. Adc l Max Input ShortCircuitCurrent 30 45 Adc . .fir'; ts ,. Reverse-Polarity Protection... ..-. .... .- :. .. Yes .. .... . .. ..... .. . . Ground-Fault Isolation Detection _ _ 6001m Sensitivity Maximum Inverter Efficiency 97 7 98 2 98 3 98 3• 98 98 98 97 5 @ 208V 97 @ 208V _ - •_ - �� 'e,�., ," CEC Weighted Efficiency 97 5 98 97 5 97 5 97 5 % i - - ------.—;"`•t •_ Nighttime D m Consumption <2.598 .. .. 5@�40V. ... ... .. .. . .. @ 240V 97 I . i l me Power Cons L ; . ADDITIONAL FEATURES' 1 , . -_.._ - Supported Communication Interfaces _ _ _ RS485,RS232,Ethernet,ZlgBee(optional) ? - I- -, o __,', q ' Revenue Grade Data,ANSI C12.1 Optional ' A,,; STANDARD COMPLIANCE - �:- s ' t 1 7 99B UL19 ■31 _____. . _ Safety.... .• UL141,UL16 98,CSA 22 2 •• - .- -. -• I -,, Grid Connection Standards• • • •• • ••• ••- •-. IEEE1547 ^- - i , ^ t' Emissions FCC part15 class B 'INSTALLATION SPECIFICATIONS : I y 1 +.,, i AC out putcondwtsrze/AWG range 3/4"minimum AWG .., •• 3/4°m,mmum/8-3AWG . . ... . . - . . .. .- t 'I -- DC Input conduit size/6 of strings/ 3/4"minimum/1-2 strings/24-6 AWG 3/4"minimum/1-2 strings/14-6 AWG 7 AWG range .. _ .... .. - - - ; Dimensions with AC/DC Safety 30.5x12.5x7/ 305x125 x75/ 305x125x105/775x315x260 in/ A„ f' , i Switch(HxWxD( 775x315x172 .•, 775x315x• • •••• mm '--. -- ---- -- --_- i Weight with AC/DC Safety Switch 512/23 2 54 7/24 7 88 4/40.1 lb/kg ! Cooling Natural Convection Fans(user replaceable) LL Nose .... ... . ... <25 <50 dBA The best choice for SolarEdge enabled systems - Mm-Max operating Temperature -13 to+140/-25 to+60(CAN versionilii-40 to+60) 'F/'C - Integrated arc fault protection(Type 1)for NEC 2011 690.11 compliance . Range • Superior efficiency(98%) ' Protection Rating .. . . . . NEMA 3R . . .. . .. . . . . .. • • • • ,- • •, ° •For other regional settings please contact SolarEdge support. — Small,lightweight and easy to install on provided bracket i ••Limited to 125%for locations where the yearly average high temperature is above 77'F/25•C and to 135%for locations where it is below 77 F/25•C. For detailed information,refer to htto.//www.solaredce us/files/odhMverter dc oversbine aulde.odf — Built-in module-level monitoring .. •••A higher current source may be used,the inverter will limit Its input current to the values stated ••CAN P/Ns are eligible for the Ontario FIT and mlcroFIT(microFfr eon SE11400A-U5-CAN) . — Internet connection through Ethernet or Wireless - — Outdoor and Indoor installation ' - • Fixed voltage inverter,DC/AC conversion only 1 ▪ Pre-assembled AC/DC Safety Switch for faster installation — Optional—revenue grade data,ANSI C12.1 0s" IEC RoHS Ei� � USA-GERMANY-ITALY-FRANCE-JAPAN-CHINA-AUSTRALIA-THE NETHERLANDS-ISRAEL www.solaredoe-us • b ,+•.Ilir dy r:'hi,I,bv- In..All uri.s n.s.,rV,1.'.01 tnUtiaf n n.11rftfp,ILpo.OL•111,117E La'•SOL ARE DOE ' aw r,id•otar,'s i i i'.gry .a'r,IJS.,-,Ir,.s 1.,lar l.1.T dry keys.hi..bl'stir.,:nod/wail,m•dnnn01 h.reh. rale 111,1 1r,e1( „'til-rrr ,., tit..'.Ir.r5.n Il'I'(j't,J 104.V.'2.nun!t IV h nlpl,va'S sit.ita... i , ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES - - A AMPERE 1. WHERE ALL TERMINALS OF THE DISCONNECTING AC ALTERNATING CURRENT MEANS MAY BE ENERGIZED IN THE OPEN POSITION, BLDG BUILDING A SIGN WILL BE PROVIDED WARNING OF THE CONC CONCRETE HAZARDS PER ART. 690.17. DC DIRECT CURRENT 2. EACH UNGROUNDED CONDUCTOR OF THE �`' EGC EQUIPMENT GROUNDING CONDUCTOR MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY i� (E) - EXISTING PHASE AND SYSTEM PER ART. 210.5. I ' I EMT ELECTRICAL METALLIC TUBING 3. A NATIONALLY—RECOGNIZED TESTING JAW ' 5 2016 Ii ' GALV GALVANIZED LABORATORY SHALL LIST ALL EQUIPMENT IN .1'�, GEC GROUNDING ELECTRODE CONDUCTOR COMPLIANCE WITH ART. 110.3. GND GROUND 4. CIRCUITS OVER 250V TO GROUND SHALL j HDG HOT DIPPED GALVANIZED COMPLY WITH ART. 250.97, 250.92(B) I CURRENT 5. DC CONDUCTORS EITHER DO NOT ENTER - Imp CURRENT AT MAX POWER BUILDING OR ARE RUN IN METALLIC RACEWAYS OR , - Isc SHORT CIRCUIT CURRENT ENCLOSURES TO THE FIRST ACCESSIBLE DC . kVA KILOVOLT AMPERE DISCONNECTING MEANS PER ART. 690.31(E). kW KILOWATT 6. ALL WIRES SHALL BE PROVIDED WITH STRAIN LBW LOAD BEARING WALL RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY MIN MINIMUM UL LISTING. (N) NEW 7. MODULE FRAMES SHALL BE GROUNDED AT THE ��� Structural Only NEUT NEUTRAL UL—LISTED LOCATION PROVIDED BY THE NTS NOT TO SCALE MANUFACTURER USING UL LISTED GROUNDING Of NEW OC ON CENTER HARDWARE. Digitally-signed by$us it Q�`� Y6 PL PROPERTY LINE 8. MODULE FRAMES RAIL AND POSTS SHALL BE ! ,N �� :,-,". . � gRIO/y Pa POINT OF INTERCONNECTION BONDED WITH EQUIPMENT GROUND CONDUCTORS AND Shenoy� `� • �� EC UPS E . StiSLocation: 421 Riverside, ``' ° PV PHOTOVOLTAIC GROUNDED AT THE MAIN ELECTRIC PANEL. E N G I N E E R I N G Inc.,P.C. _ " 1*- o cc SCH SCHEDULE 9. THE DC GROUNDING ELECTRODE CONDUCTOR STEI421-,Spokane,W_WA f,dt. ' �, SS STAINLESS STEEL SHALL BE SIZED ACCORDING TO ART. 250.166(B) & Contact Info.'509=921- 731 Eclipse Engineering,as a third party, 2 � ..rt- -*---' _ STC STANDARD TESTING CONDITIONS 690.47. has provided a structural-only review of Fp 095379 TYP TYPICAL Date: 2015.1'2 03 the enclosed project. X090 ,p,\. UPS UNINTERRUPTIBLE POWER SUPPLY 12:07:28-08'00' FESs10 V VOLT Vmp VOLTAGE AT MAX POWER Voc VOLTAGE AT OPEN CIRCUIT VICINITY MAP INDEX W WATT 3R NEMA 3R, RAINIIGHT 0y f PV1 COVER SHEET .. - PV2 SITE PLAN r • '• `, r PV3 STRUCTURAL VIEWS : " PV4 STRUCTURAL VIEWS , t ' ' 'it.,:, ' PV5 THREE LINE DIAGRAM LICENSE GENERAL NOTES .; Cutsheets Attached 1. THIS SYSTEM IS GRID—INTERTIED VIA A ;`', , ki UL—LISTED POWER—CONDITIONING INVERTER. ... N 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. . pr 3. SOLAR MOUNTING FRAMES ARE TO BE GROUNDED. - y�`,Lj I 4. ALL WORK SHALL COMPLY WITH THE 2010 -131 , MODULE GROUNDING METHOD: ZEP SOLAR R.C.N.Y.S. _' A, 5. ALL ELECTRICAL WORK SHALL COMPLY WITH ' ` I REV BY DATE COMMENTS AHJ: Southold Town THE 2008 NATIONAL-ELECTRIC CODE. - , .;,#• .• 4L ' . , ;'���DATE COMMENTS ss _ UTILITY: Long Island Power Authority (LIPA) - 9.08-1.c. - ©©©S- 1 . talGl,obe,, New York GIS;,. USDA Farm �Service'Alen am= * CONFIDENTIAL— THE INFORMATION HEREIN ,OB NUMBER: JB-119179 O O PREMISE OWNER. ;;:SKI DESIGN:EUGENE RESIDENCE Jeff Bunca ''''SolarCity BENEFIT OF ANYONE EXCEPT SOLARCITY INC„ MOUNTING SYSTEM: A 4,0 NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 2230 SOUNDVIEV�' AVE 18.5 KW PV ARRAYPIN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION HATH MODULES: M ATTI TU CK, N Y 11952 THE SALE AND USE OF THE RESPECTIVE (74) YINGLI # YL250P-29b3055 Clearvtew Way SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME SHEET: REV: DATE: San Mateo,CA 94-402 INVERTER: 6312987688 PV 1 b 12/2/9n19 (888)—SOL—CITY 'Z°ss 2489)0 a) 'raoeyaan PERMISSION OF SOLARCITY INC Multi.le Inverters COVER SHEET PITCH:43 ARRAY PITCH:43 0 MP1 AZIMUTH:220 ARRAY AZIMUTH:220 ' MATERIAL:Comp Shingle STORY: 2 Stories PITCH: 35 ARRAY PITCH:35 N W MP2 AZIMUTH:130 ARRAY AZIMUTH:130 ' MATERIAL:Comp Shingle STORY: 2 Stories , a (E)DRIVEWAY PITCH:43 ARRAY PITCH:43 _ IMP3 AZIMUTH:220 ARRAY AZIMUTH:220 t - MATERIAL:Comp Shingle STORY: 2 Stories_ PITCH:43 ARRAY PITCH:43 MP4 AZIMUTH:220 ARRAY AZIMUTH:220 - MATERIAL:Comp Shingle STORY: 2 Stories PITCH:43 ARRAY PITCH:43 MP5 AZIMUTH:130 ARRAY AZIMUTH:130 'CPMATERIAL:Comp Shingle STORY: 2 Stories PITCH:43 ARRAY PITCH:43 / / MP6 AZIMUTH:-220 ARRAY AZIMUTH:220 I�����i am `i' o 0 0 a a . MATERIAL:Comp Shingle - STORY: 2 Stories - 0 s a i rL�='CI° 0 0 a ,4 0 0 0 I‘InV� IF„ i CI o C C D e O. '� o e `r,MP/ o . a a 11�,; CI ' e G Ili) LEGEND I,Inv% . o 0 L_i a O 0 Q (E) UTILITY METER & WARNING LABEL a 0 ® INVERTER W/ INTEGRATED DC DISCO , ,s�y a - a & WARNING LABELS 8dW F'$ c • a a ' ® DC DISCONNECT & WARNING LABELS cf. MI 101.11101.111111.11 Il AC DISCONNECT & WARNING LABELS - e ale a a a a O DC JUNCTION/COMBINER BOX & LABELS 0 0 ki,�MP3 a = Q -DISTRIBUTION PANEL & LABELS .,./ • LC LOAD CENTER & WARNING LABELS _ a q O DEDICATED PV SYSTEM METER Stnictural Only Q STANDOFF LOCATIONS pF NE CONDUIT RUN ON EXTERIOR � W y - ®®® CONDUIT RUN ON INTERIOR c�P $ IpN S �q1 — — GATE/FENCE �ti)1 � y� 0 HEAT PRODUCING VENTS ARE RED * fakt{� * �e_1 INTERIOR EQUIPMENT IS DASHED i_-,'...1 ;fir y� .•.�y, SITE PLAN cO 095319 7 AR°FfSS10NA~� Scale:1/16" = 1' LI 01' 16' 32' y� C) ..� �., CONFIDENTIAL-THE INFORMATION HEREIN JOB NUMBER JB-119179 0 0 PREMISE OWNER: DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE KRUPSKI, EUGENE KRUPSKI RESIDENCE Jeff Bunca ts:-SolarCityBENEFIT OF ANYONE EXCEPT SOIARCITY INC.. MOUNTING SYSTEM NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 2230- SOUNDVIEW AVE 18.5 KW PV ARRAY PI; PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES MATTITUCK, NY 11952 ORGANIZATION, EXCEPT IN CONNECTION WIN 3055 Cleor ew Way THE SALE AND USE OF THE RESPECTIVE (74) YINGLI # YL250P-29b PAGE NAME SHEET: REV DATE San Mateo,CA 94402 PERMISSION OFISO�. WITHOUT THE WRITTEN �'�'� 6312987688 PV 2 b 12/2/2015 (Benj SOL-an(7655-2489)ow)ww638-1029 olar'aoIty.c Multiple Inverters SITE PLAN ___ Structural Only „ 007,* `c QF NEwl---- / (E) 2x6 5'P vFtIO/�.S 9i- y sem. / ``O 095379 �� / 114V.1 -1:" . . , 0 _ 7 1 6 0 0, 4"0/1/11/ ;j '-2" 7'-4" - j, ■_i 1'-' (E) LBW !I (E) LBW O SIDE VIEW OF MP1 NTS o SIDE VIEW OF MP2 NTS MP1 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES ' LANDSCAPE 64" 23" STAGGERED MP2 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES PORTRAIT 32" 14" LANDSCAPE 64" 23" STAGGERED ROOF AZI 220 PITCH 43 PORTRAIT 32" 14" RAFTER 2x10 @ 16"OC ARRAY AZI 220 PITCH 43 STORIES:2 RAFTER 2x10 @ 16"OC ROOF AZI 130 PITCH 35 STORIES:2 Ci. 2x10 @16"OC Comp Shingle ARRAY AZI 130 PITCH 35 C.J. 2x10 @16"OC Comp Shingle z, PV MODULE i�l� 5/16" BOLT WITH LOCK INSTALLATION ORDER & FENDER WASHERS LOCATE RAFTER, MARK HOLE ZEP LEVELING FOOT (1) LOCATION, AND DRILL PILOT ZEP ARRAY SKIRT (6) HOLE. (4) �2) SEAL PILOT HOLE WITH / ZEP COMP MOUNT C �. IMMONFAMONIM - POLYURETHANE SEALANT. �\� ZEP FLASHING C �t��T� ��?_-- (3�_ INSERT FLASHING. (E) COMP. SHINGLE (4) PLACE MOUNT. (E) ROOF DECKING `� 10-g L. INSTALL LAG BOLT WITH 5/16" DIA LAG BOLT (5) SEALING WASHER. (E) LBW WITH SEALING WASHER LOWEST MODULE SUBSEQUENT MODULES INSTALL LEVELING FOOT WITH O SIDE VIEW OF MP3 NTS (2-1/2" EMBED, MIN) (6)_ BOLT & WASHERS. (E) RAFTER MP3 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES STANDOFF LANDSCAPE 64" 23" STAGGERED $1) PORTRAIT 32" 14 Scale: 1 1/2" = 1' RAFTER 2x10 @ 16"OC ROOFAZI 220 PITCH 43 STORIES.2 ARRBRAYY AZI 220 PITCH 43 C.J. None @16"OC Comp Shingle J B-11917 9 00 'PREMISE OWNER: DESCRIPTION: DESIGN: CONFIDENTIAL- 1HE INFORMATION HEREIN JOB NUMBER: 1-‘k's13SolarCity CONTAINED SHALL NOT BE USD FOR THE ' KRUPSKI, EUGENE KRUPSKI RESIDENCE Jeff Bunco BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 2230 SOUNDVIEW AVE 18.5 KW PV ARRAY - ►�� PART TO OTHERS OUTSIDE THE RECIPIENT'SMooULEs M ATTI TU CK, NY 11952 ORGANIZATION, EXCEPT IN CONNECTION WITH 3055 CleanAew Way THE SALE AND USE OF 1HE RESPECTIVE (74) YINGLI # YL250P-29b PAGE NAME SHEET: RETC DATE San Mateo,CA 94402W 638-1029 PERMISSION OFSOLARCITY ISOLARCITY INC. THE WRITTEN M4fRTER T6312987688 PV 3 b 12/2/2015 (888)SOL CITY((765-24850)638-1028 9)�www.salarc com ___ Multiple Inverters STRUCTURAL VIEWS _ kk . . i® Structural Only ` pF NEyi k. co S I- r.: 1404' O cc O °95319 <C, (E) LBW pROFESSIO' © SIDE VIEW OF MP8 NB MP8 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES LANDSCAPE 64" 23" STAGGERED PORTRAIT 32" 14" ROOF AZI 40 PITCH 43 . - RAFTER 2x10 dal 16"OCARRAY AZI 40 PITCH 43 STORIES:2 Comp Shingle PV MODULE 5/16" BOLT WITH LOCK INSTALLATION ORDER & FENDER WASHERS LOCATE RAFTER, MARK HOLE ZEP LEVELING FOOT (1) LOCATION, AND DRILL PILOT ZEP ARRAY SKIRT - (6) HOLE. C./.._ SEAL PILOT HOLE WITH ZEP COMP MOUNT C (4) POLYURETHANE SEALANT. �A �►� f N ISI I: * ZEP FLASHING C -1L� T� Illirti -- (3)_ INSERT FLASHING. (E) COMP. SHINGLE (4) PLACE MOUNT. (E) ROOF DECKING M INSTALL LAG BOLT WITH 5/16" DIA LAG BOLT (5) (5) SEALING WASHER. WITH SEALING WASHER LOWEST MODULE SUBSEQUENT MODULESINSTALL LEVELING FOOT WITH (2-1/2" EMBED, MIN) (6) BOLT & WASHERS. (E) RAFTER STANDOFF Si Scale: 1 1/2" = 1' CJ B-11917 9 00 PREMISE OWNER. DESORPTION: DESIGN: CONFIDENTIAL- THE INFORMATION HEREIN JOBINFORMATIONR *1SolarCity CONTAINED SHALL NOT BE USED FOR THE KRUPSKI, EUGENE KRUPSKI RESIDENCE Jeff Bunco �_ BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM:NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 2230 SOUNDVIEW AVE 18.5 KW PV ARRAY r PART TO OTHERS OUTSIDE THE RECIPIENTS MODu�s MATTITUCK, NY 11952 ORGANIZATION,EXCEPT IN CONNECTION WITH 3055 CleaMew Way THE SALE AND USE OF THE RESPECTIVE (74) YINGLI # YL250P-29b PAGE NAME SHEET REV DATE San Mateo,CA 94402 PESORMISSION OFCITY ISOLARCITY INC. THE WRITTEN IN�R1t� 6312987688 PV 4 b 12/2/2015 (888)SOL-C1Y) (765-2489)www.solarctty.com Multiple Inverters STRUCTURAL VIEWS GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND (N) #8 GEC TO (N) GROUND ROD Panel Number:NoMatch Inv 1: DC Ungrounded INV 1-(1)ABB#PN-5000-OUTD-US-Z-A A -(74)YINGLI # YL250P-29b AT PANEL WITH IRREVERSIBLE CRIMP Meter Number.099054493 Inv 2: DC Ungrounded FCl Inverter; Zigbee 5000W,240V,9b.ox PV Module; 250W, 226.2W PTC, H4, 40mm, YGE-Z 60, Black Frame, ZEP Enabled Underground Service Entrance Inv 3: DC Ungrounded INV 2-(1)ABB I PVI-5000-0UTD-US-Z-A B - Tie-In: Supply Side Connection Fa Inverter, Zigbee 5000W,240V, Voc: 37.6 Vpmax: 29.8 INV 3-(1)ABB Inlvertteer4Z2iabeee42 0W 24Z0V 95X C Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER E 150A MAIN SERVICE PANEL (E 150A/2P MAIN CIRCUIT BREAKER ADJUST MIN. ACTIVATION VOLTAGES! SolarCity (E) WIRING CUTLER-HAMMER BRYANT Inverter 1 IND s I Vstart= 183V I Disconnect �(N) 125A Load Center 13 ABB Dc. © B 90A PVI-5000-0UTD-US-Z-A - P DG MP 1: 1x6 C 30A/2P 1- • 1 — --17 EGG /!!!`-��---"----'3�� • A �.© •�•-- I� I t 2 Vstart=200V 150A/2P B ,j____ = • .� DC. I DC+ N DG I (7� c" it I , (E)LOADS *JLQP,__N _ EGCI .� DC. _ x j J �c. MP 1: 2x10 I' _ _i t o i__- GEC 1N DC- III G 1 OG . I�, I rlifrEt J z I II GND __ EGC--- _ -_17 - GC '1 , IR r---- I _ 1 i r.r..0.J ' I ADJUST MIN. ACTIVATION VOLTAGES! (1)Condult Kit 3/4'EMT SolarCity I - I - - - - •N I I - Inverter 2 IND to A 3 I I 14 ABB n DC+ Vstart= 183V =-= 1 I •PVI-5000-OUTD-US-Z-A I DG MP 2: 1x6 I - I 30A/2P 1 _ __i EGC caj 1 I r- GEct i ��� 1 �I ✓ Dc. i I c+ Vstart=200V TO 120/240V I I �r N -�� DG I !__. �'D SINGLE PHASE EGC/ .� DC+ • DC �, UTILITY SERVICE i TJ - DEC 1� -+_ DG _ .• 7G MP 2: 2x10 l, II I 1 I tllh��IIIGND I____EGC__ - =GC 1 -tE ADJUST MIN. ACTIVATION VOLTAGES! (1)Conduit Kit; 3/4'EMT SolarCity --L I Inverter 3 IND _ I1 Dc+ Vstart=200V 15 ABB A 5 PVI-4.2-OUTD-S-US-Z-A Dc- MP 8: 1x11 EGC ON ROOF TO BE ROUTED WHERE NOT SUBJECT TO �.A/� - I� — EGC cTI-i PHYSICAL DAMAGE. WHEN ROUTED SUBJECT TO PHYSICAL 1 1 LI EI _ DC+ DAMAGE THE SIZE MUST BE INCREASED TO #6 SOLID BARE I - �' •" I N =1_4.----— DC- I t- !C+/-1 COPPER. I -'_ Vstart=200V- _ _ I EGCI _I � DC+ - c_Fli cEC 4L4J. DG - G MP 3: 1X11 II GND I_ EGC _ __� GC J Voc* = MAX VOC AT MIN TEMP (UCondu@ Kit 3 4'EMT pp I—(1)G5/8 ROI g —(1)=8-HAMMER g DG223NR6 � A —(3)SdarCiti/4 SIRING AINCTION BOX DC 5 8 x 8,Copper Disconnect; t00A 240VaG Fusible,NEMA 3R /q 1 2x2 STRINGS,UNFUSED,GROUNDED —(2)ILsco j IPC 4/0-2/0 —(1)CunER— MERKI DGIDONB Insulation Piercing Connector, Main 4/0-2 Tap 2/0-6 Ground Neutral it; 60-100A,General Duty(DG) SSC-SUPPLY SIDE CONNECTION.DISCONNECTING MEANS SHALL BE SUITABLE —(1)CUTLER—HAMMER aass R se tl MAC AS SERVICE EQUIPMENT AND SHALL BE RATED PER NEC. —(2)FERRAZ SHAWMUT 11R90R PV BACKFEED OCP Fuse; 90A,250V,Class RK5 C F_(1)BRYANT I BR816L1251213 Load Center; 125A,120/240V,NEMA 3R —(1)CUTLER—HAMMERI BR225 —(2)CURER—HAMMER#BR230 Breaker; 25A2P,2 Spaces Breaker; 30A/22P,2 Spaces �"(1)AWG 14,THWN-2,Black (1)AWG 110,THWN-2,Black (1)AWG#10,THAN-2,Black Voc* =424.13 VDC Isc=17.84 ADC —(2)AWG 110,PV Wire,600V,Black Voc* =254.48VDC Isc=8.92 ADC ®II-(1)AWG 1HWN-,RED ©�(1)AWG TIO,THWN-2,Red O (1)AWG 110,THWN-2,Red Vmp =298 VDC Imp=16.78 ADC O'-(1)AWG 16,Solid Bare Copper EGC Vmp =178.8 VDC Imp=8.39 ADC (1)AD piemI9#1-11,White NEUTRAL Vmp =240 VAC Imp=66 MC (1)AWG#10,MN-2,White NEUTRAL Vmp =240 VAC Imp=23 MC 1)AWG j10,1HHN/THWN-2,Green EGC.. —441)AWG 18,1HWN-2,Green EGC/GEC,-(1)CQ4DUIT KIT —(1)AWG�,1HWN-2,Green..EGC/GEC,—(1)Conduit Kit; 3/4;EMT (1)AWG I10,1HIWI-2,Black Voc* =254.481%DC Isc=8.92 ADC [�(4)AWG TIO,PV YBre 601W,Black Voc* =424.13 VDC Isc=t3.!)2 •ADC (1)AWG/3,7HWN-2 Black 1 x 10 EMT Conduit ' • ''' (1)AWG#10,1HWN-2 Black ®�(1)AWG 110,1HWN-2 Red Vmp =178.8 VDC Imp=8.39 ADC O Iu,E(1)AWG E6,Solid Bare Copper EGC Vmp =298 VDC Imp=8.39 ADC ©�(1)AWG R,THWN-2 Red ®RE(1)AWG 110,THWN-2,Red - .- (1-)AWG 1n0,1HHN/1HWN-2 Green,EGC • (1)AWG 13 1HWN-2 White NEUTRAL Vmp =240 VAC Imp=66 AAC (1)AWG 110,THAN-2,White NEUTRAL Vmp =240 VAC Imp=23 AAC (1)AWG 110,TH11N-2,Black Voc* =424.13VDC Isc=1 .84 ADC . (2)AWG 110,PV Wire,600V,Black. Voc*.=254.48VDC Isc=8.92 ADC (1)AWG/6,Solid Bare Copper.GEC. - -(1)CQ)iDUIT KIT —{1)AWG1'8,THWN-2,Green EGC/GEC—(1)Condult Kit.3/4'EMT , , O'A—(1)AWG#10,THWN-2,Red Vmp =298 VDC Imp=16.78 ADC O-4—(-1)AWG 16,Solid Bare Copper EGC Vmp =178.8 VDC Imp=8.39 ADC •1 x 10'EMT Conduit . ''' (1)AWG 110,THWN-2,Black , 1)AWG 110,JHHN/THWN-2,Green EGC ®k(1)AAG 110,THAN-2,Red I-(1)AWG 110,THWIN-2,Black Voc* =254.48 VDC Isc=8.92 ADC •�r (4)AWG 110,PV WWre 600V,Black •• Voc* =424.13 VDC Isc=8.92 ADC ���LLL(1)AWG 110,7HWN-2 White NEUTRAL Vmp =240 VAC Imp=20 MC IQF(1)AWG 110,1HWN-2 Red Vmp =178.8 VDC Imp=8.39 ADC ®1k7�F(1)AWG 16,Solid Bare Copper EGO Vmp =298 VDC Imp=8.39 ADC -(1)AWG 48.THWM-2,Green EGC/GEC-(1)Conduit Kit: 3/4'EMT ISL 1 AWG 110.THHN/THWN-2.Green EGC f� 1 AWG#10,THWN-2,Black - Voc* =466.54VDC Isc=8.92 ADC (2)AWG#10,PV Wire,600V,Black Voc* =466.54VDC Isc=8.92 ADC ©Ic+1..(1)AWG 110,THWN-2,Red Vmp =327.8 VDC Imp=8.39 ADC O (1)AWG/6,Sdid Bare Copper EGC Vmp =327.8 VDC Imp=8.39 ADC III���(1)AWG/10,IHHN/IHWN-2,_Green EGC IBJ (1)AWG#10,1HWN-2,Black Voc* =•466.54VDC Isc=8.92 ADC 0 r(2)AWG 110,PV Wire,6•00V,Black•• ••Voc* =46DC 6.54VIsc=6.62 ADC - - ©§-(1)AWG#10,THWN-2,Red Vmp =327.8 VDC Imp=8.39 ADC ©ITS-(1)AWG 6,Solid Bare Copper EGO Vmp =327.8 VDC Imp=8.39 ADC .. (1)AWG 110,1HHN/IHWN-2,Green EGC . 1 CONFIDENTIAL—THE INFORMA710N HEREIN J08 NUMBEJ B R -119179 00 PREMISE OWNER: DESCRIPTION:. - DESIGN: CONTAINED SHALL NOT BE USED FOR THE KRUPSKI, EUGENE KRUPSKI RESIDENCE Jeff Bunca .'"11'SOIarCity BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: - �'�" NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 2230 SOUNDVIEW AVE - 18.5 KW PV ARRAY ►I% PART TO OTHERS OUTSIDE THE RECIPIENTS MODDIES MATTITUCK, NY 11952 ORGANIZATION, EXCEPT IN CONNECTION WITH 3055 CleMarvieey Wa THE SALE AND USE OF THE RESPECTIVE - (74) YINGLI # YL25OP-29b SHEET: REV: DATE: San 5ale 94402 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME INVERTER: T:(650)638-1028 F:(650)638-1029 PERMISSION OF SOLARGITY INC. Multiple Inverters 6312987688 THREE LINE DIAGRAM PV 5 b 12/2/2015 (888)—SOL OITY(765-2489)e,»t,.solarclty.com WARNING:PHOTOVOLTAIC POWER SOURCE Label Location: Label Location: Label Location: (C)(CB) WARNING (AC)(POI) WARNING (DC)(INV) Per Code: Per Code: Per Code: ELECTRIC SHOCK HAZARD ELECTRIC SHOCK HAZARD NEC 690.31.G.3 NEC 690.17.E NEC 690.35 F DO NOT TOUCH TERMINALSTHE DC CONDUCTORS OF THIS ( ) Label Location: TERMINALS ON BOTH LINE AND PHOTOVOLTAIC SYSTEM ARE TO BE USED WHEN PHOTOVOLTAIC DC (DC)(INV) LOAD SIDES MAY BE ENERGIZED UNGROUNDED AND INVERTER IS DISCONNECT Per Code: IN THE OPEN POSITION MAY BE ENERGIZED UNGROUNDED NEC 690.14.C.2 Label Location: Label Location: PHOTOVOLTAIC POINT OF (P01) MAXIMUM POWER- A (DC)(INV) INTERCONNECTION Per Code: ARNINPOINT CURRENT(Imp)_ Per Code: �VHHAZARAZAR : ELECTRIC SHOCK NEC 690.17.4; NEC 690.54 D.DO NOT TOUCH MAXIMUM POWER- POINT VOLTAGE(Vmp) V NEC 690.53 TERMINALS.TERMINALS ON _ BOTH THE LINE AND LOAD SIDE MAXIMUM SYSTEM VOLTAGE(Voc)_V MAY BE ENERGIZED IN THE OPEN SHORT-CIRCUIT POSITION.FOR SERVICE CURRENT(Isc)_A, DE-ENERGIZE BOTH SOURCE AND MAIN BREAKER. _ PV POWER SOURCE • MAXIMUM AC A OPERATING CURRENT MAXIMUM ACV Label Location: OPERATING VOLTAGE _ WARNING (DC)(INV) Per Code: ELECTRIC SHOCK HAZARD IF A GROUND FAULT IS INDICATED NEC 690.5(C) NORMALLY GROUNDED Label Location: MAY BE UNGROUNNDEDORS AND ENERGIZED CAUTION (P01) DUAL POWER SOURCE Per Code: SECOND SOURCE IS NEC 690.64.6.4 PHOTOVOLTAIC SYSTEM Label Location: WARNING (DC)(CB) ELECTRICAL SHOCK HAZARD Per Code: Label Location: DO NOT TOUCH TERMINALS NEC 690.17(4) CAUTION (D)(P01) TERMINALS ON BOTH LINE AND Per Code: LOAD SIDES MAY BE ENERGIZED PHOTOVOLTAIC SYSTEM IN THE OPEN POSITION CIRCUIT IS BACKFED NEC 690.64.6.4 DC VOLTAGE IS ALWAYS PRESENT WHEN SOLAR MODULES ARE EXPOSED TO SUNLIGHT Label Location: WARNING (P01) Per Code: Label Location: INVERTER OUTPUTNEC 690.64.B.7 CONNECTIONN PHOTOVOLTAIC AC (AC)(P01) DO NOT RELOCATE (AC):AC Disconnect Per Code: THIS OVERCURRENT (C): Conduit DISCONNECT NEC 690.14.C.2 DEVICE (CB):CB Combiner Box (D): Distribution Panel (DC): DC Disconnect (IC): Interior Run Conduit Label Location: (INV): Inverter With Integrated DC Disconnect MAXIMUM AC _ A (AC) (P01) (LC): Load Center OPERATING CURRENT Per Code: MAXIMUM AC _ V NEC 690.54 (P01): M): Utility Meter OPERATING VOLTAGE POI : Point of Interconnection CONFIDENTIAL- THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR -�i 44 3055 Clearnew Way THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED �- • San Mateo,CA 94402 IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, Label Set ��►' T.(650)638-1028 F.(650)638-1029 EXCEPT IN CONNECTION PATH THE SALE AND USE OF THE RESPECTIVE /� �O'� '�� (888) -2489)wwwsolaraty.com -___ -- SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. 0 r SOIarCity I ®pSolar Next-Level PV Mounting Technology sSOlarCity I ®pSolar Next-Level PV Mounting Technology Z@System Components �_.�� p � -� for composition shingle roofsill af� , 1,10 . . a Up roof r t Leveling Foot f , Ground Zep — Xm`rluck dw°j eni Part No.850-1172 ::i _...._.' Leveling Foot O ETL listed to UL 467 i t t 5 Zep Compatible PV Modals - t el Zep Groove -�^°' r' , . , . t — 1/4 - Array Skirt 111 "'"-'"�-�"` - Comp Mount _�_ - '.x- rr S' ," i - Part No 850.1382 Listed to UL 2582 E Mounting Block Listed to UL 2703 a �peMPAr/e "- -- -- _. h (,� Des•cription �A®0v PV mounting solution foPcomposition shingle roofs r T_, j�'`lli V r- Works with all ZepCompatible Modules ...ii--..,,...,._...i.i i....../4 A 1 00MP0 • Auto bonding UL-listed hardware creates structural and electrical bond • Zep System has a UL 1703 Class"A"Fire Rating when installed using modules from any manufacturer certified as"Type 1"or"Type 2° Interlock Ground Zep V2 DC Wire Clip 43 LISTED Specifications Part No 850-1388 Part No.850-1511 Part No.850-1448 Listed to UL 2703 Listed to UL 467 and UL 2703 Listed to UL 1565 • Designed for pitched roofs • Installs in portrait and landscape orientations • Zep System supports module wind uplift and snow load pressures to 50 psf per UL 1703 f • Wind tunnel report to ASCE 7-05 and 7-10 standards 51 • Zep System grounding products are UL listed to UL 2703 and UL 467 1111111116 • Zep System bonding products are UL listed to UL 2703 � r • Engineered for spans up to 72"and cantilevers up to 24" - Irk, • Zep wire management products listed to UL 1565 for wire positioning devices ' 4fr� • Attachment method UL listed to UL 2582 for Wind Driven Rain - " Array Skirt,Grip,End Caps Part Nos 850-0113,850-1421, 850-1460,850-1467 zepsolar.com zepsolar corn Listed to UL 1565 This document does not create any express warranty by Zep Solar or about its products or services.Zep Solar's sole warranty is contained in the written product warranty for This document does not create any express warranty by Zep Solar or about its products or services Zep Solar's sole warranty is contained in the wntten product warranty for each product.The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty The customer is solely each product.The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty The customer is solely responsible for venfying the suitability of ZepSolar's products for each use Specifications are subject to change without notice Patents and Apps zspats com responsible for venfying the suitability of ZepSolar's products for each use Specifications are subject to change without notice Patents and Apps zspats coin Document#800-1890-001 RevA Date last exported November 13,2015 2 23 PM Document#800-1890-001 RevA Date last exported November 13,2015 2 23 PM „ 'Y' .-” i / ,,' „y /N / / '/. . „ , - / , , , , � YG .Z :60l ,./ TELL • Y/` s ¢��, YG 60 CELL sEROEs / , /YL250P-�9. Powered by YINGU 'S E R FSS YL245P-29b / , YINGL� 1 SOLAR 'YL24/OP•2 16 r ' ELECTRICAL PERFORMANCE S f Electrical parameters at Standard Test Conditions(STC) _ _ _ _ sJ / / ! / ` r Module typo YL260P-296 VL255P-296 YL250P-296 YL245P-29b YL240P•29b / / // / i i i s Power output P... W 260 255 250 245 240 / / /s /s / / i' Power output tolerances AP.... % -0/+3 - \/\\/ // / Module efficiency rico % e 160 157 15A 15.7 148 \'! s / '�� Voltage at P,m tr.vn V d 30.3 30.0 29 8 1 29 6 1 29 3 t. Current at P... I.� A 859 8.49 839 828 818 / /" /•/ THE IDEAL SOLUTION '' /� / /' / Open-circuit voltage V.. V I 37.7 37.7 37.6 37.5 375 / / /" 1 FOR HOMEOWNERS Short-circuit current I. A 909 901 892 __ 883 875 s !� ��' STC.1000W/m'irradiance,25°C cell temperature,AM I 50 spettrum according to EN 60904-3 -- /' / /' a Maximum power output P at multiple rating conditions of temperature and irradiance /' / / d Temperature Irradiance YL260P-29b YL255P"29b YL250P-29b YL245P-29b YL24OP-29b / / f j The Zep Compatible TM YGE-Z 60 Cell Series delivers superior performance °c "L/n'' "' `" "L W W" ;// / i / and an elegant aesthetic in residential applications.When mounted with High Temperature Condition HrC 75 1000 203.7 199 8 195.9 192.0 1881 I Nominal Operating Cell Temperature NOCi 46 800 190 6 186 9 183.2 179 5 ` 175.9 �% /� /�f 1 Zep racking systems,it allows for lower balance of system costs and reduced / �� / i Low Temperature Condition , LTC 15 ! 500 135.7 133.1 130.5 1279 125.3 X / / - ( installation times. ` ( ' //\��fr / Low Irradiance Condition LIC 25 200 50.3 49 4 48.4 47A 46.5 Trusted Partner OPERATING CONDITIONS THERMAL CHARACTERISTICS Units:Inch(mm) //` ��`Yingli is one of the world's largest solar module manufacturers with over 10 GW Max system voltage uL 1oo0Voc Temperature coeffaent of P.. :9eK i -0A3 -- _^_ ___. �i ��, deployed worldwide,and Yingli modules are trusted by leading energy providers and Max series fuse rating iSA Temperature coefficient of V. 9N C -0"32 3898(990) financial institutions in more than 85,000 projects In the Americas Limiting reverse arrant 15A Temperature coefficient of 1.. 16PC 004 g 3625(936) 157(401 16.oO/0 I1 Operating temperature range -40 to 185'F(d0 to 85°Q Temperature coefficient of V...,,.. %/C; -0.42 ;LI I Max.hailstone Impact(diameter/nelodty) 25mm/23mJs MAXIMUM EFFICIENCY 1 More Energy per Watt Yingli modules deliver superior power output in a variety of temperature and irradiance CONSTRUCTION MATERIALS "./8 06 conditions,and self-cleaning anti-reflective coated glass reduces soiling to help n 25 YEAR Front cover(material/thickness) low-iron tempered glass/3 2mm { maximize power output Performance is backed by our 25-year linear warranty i j - Call(quant,ty/material/dimensions) 60/mulsoystalsne s5/ i R g g 156mm x 156mm a 3 _ LINEAR POWER WARRANTY _ _ Grou ding holese _ ___ _ _ — __} Designed tO Outlast Emapsulant(material) ethylene vinyl acetate(EVA) b-o0236i6) T4 3 :SrA Tested to the industry's most rigorous durability standards,Yingli modules are PID- Backsheet(material/color) fluoropolymer-based with EVA pnmer/white or blade 0-3O/O resistant in conformance with IEC 62804(draft).To ensure reliable performance,Yingli Frame(material/color) anodized aluminum/black uses quality components such as DuPont."'Tedlar®PVF film-based backsheets Junction box(ingress protection raging) z1P65 Mourning holes POWER TOLERANCE ! 4-025600515(65x8) °_ Cable(length/cross-sectional area) 1200mm/4mm' Connector(type/ingress protection rating) _) Am henol H4/IP68 jBest-In-Class Technical Support a g p a 8-012oe hales 1 Yingli's locally-based engineering team is trained in system design and operations to N 17.8-01200515(3x5) `w 1_i provide field-support and value-added after sales services,including commissioning GENERAL CHARACTERISTICS z 394(100) and field-testing support Our PV Testing Lab in California provides a resource for Module dimensions R/w/H) 6457n(i640Txn)/38.98in(990rtvry/1s7in(aamr) 1 evaluating technical inquines Module weight 434165(197kg) //047(1 `\\\ 1 1 Number of modules per pallet 26 / \ INumber of pa)(ets per 40'container 28 % V. """ \\ Warranty Information - Ten-year limited product warranty Industry leading 25-year performance warranty adds value Packaging box dimensions(L/W/H) 67.32n(1710mn)/45.67n(1160meN/4638n0178nm) I Ef, 1 by guaranteeing power output on an annual basis,in compliance with our warranty terms and SEC ION C-C Packaging box weight t2021bs(545kg) 1 R conditions \ / Fire dassdicabon type Type 1 \ L-2 / Performance Modeling \ / For those interested in obtaining module performance modeling files for system energy yield \'�,/ /7\Warning Read the Installation and User Manual in its entirety before handling,installing,and operating Yngh modules ------/ simulation,please contact Yingli at simulation@yingliamericas corn. 1 Qualifications&Certificates { UL 1703 and UL 1703,CEC,FSEC,ISO 9001 2008,ISO 14001 2004,BS OHSAS 18001 2007,SA8000 i Yingli Green Energy Americas,Inc. gY ® - \ en.., ^_� QeaMPAr, info�yingliamerieas.eom l Tel:+1 (888)686-8820 ./ C us .,- ! 0100 00, . `e YINGLaI SOL.AIR + l ° '°°°"° O. YINGLISOLAR.COM I NYSE:YGE YINGLISOLAR.COM iOLTAI=D --cR6ainlaI _ __1 rF (PHOTOVOLTAIC MODULE) S-CEnnnEm i_o_nos° i 'O C0 P) G o n )Green EnergyHoldingCo.Ltd YGEZ6OCellSenes2014_EN 201501_V01 4400 ___ _ M 9 Df:*". MTedl°Iwai.., v°demerNe/EIdu Poco deN =sd.C°mprryatiVrn hew.&me 1,J8 dalmnealma rc,s.>weeduMamwWee�od�mr9.••Jwrtmwrmra Solar inverters Additional highlights. — RS-485 communication interface !ABB string (fforconnectiontolaptop ordata , ABB L3 inverterslogger). PVI-5000/6000-TL-OUTD - Integrated Arc Fault Detection and 5kW to 6 kW Interruption(-A Version). • .1._ i Technical data and types AID I Type code PVI-5000-OUTD-US PVI-6000-OUTD-US I Input side I vt .7. «r' Nominal output power 5000W 6000W (— r;, Maximum output power 5000W 6000W — Rated grid AC voltage 208V 240V 277V 208V 240V 277V I Input side(DC)' Number of Independent MPPT channels _ - 2 l Maximum usable power for each channel 4000W .1 Absolute maximum voltage(Vmax) 600V :!-------- Start-up voltage(Vstart) 200V(adj.120-350) I Full power MPPT voltage range 200-530V LOperating MPPT voltage range 0.7 x Vstart-580V Maximum current(Idcmax)for both MPPT in parallel _ 36A Maximum usable current per channel 22A )' ^'" i Number of wire landing terminals per channel 2 Pairs , ___-1 Array wiring termination Terminal block,pressure clamp,AWG16-AWG6 I Output side(AC) I Gnd connection type 10/2W Split-0/3W 10/2W 10/2W Split-0/3W 10/2W Adjustable voltage range(Vmin-Vmax) 183V-228V 221V-264V 244V-304V 183V-228V 211 V-264V 244V-304V Grid frequency _ 60Hz Adjustable grid frequency range _ 57-60.5Hz Maximum current(1.,,,,,,,-)A 27A, 23A 20A„ 30A.5 28A, 24A Designed for residential and small The wide input voltage range Highlights: Power factor >0.995 _ 9 Total harmonic distortion at rated power <2% commercial PV installations,this makes the inverter suitable to low - Single phase and split phase output 36.25 A 1 36.5 A / 31 75 A 1 36.25 A 1 36 5 A0,/ 31 75 Ab/ Contributory fault current 25.63 °� 25 81 ° 22.45 °k 25.63 °k 25 81AR 22.45A` inverter fills a specific niche in the power installations with reduced grid connection. Gnd wino termination "S pressure clamp,AVG14-AWG4 FM5 FMS stringsize. 9type Terminal block, ABB product line to cater for those — Wide input range for increased 1lnput installations producing between The transformerless operation offers stringing flexibility Reverse polarity protection _ Yes _ 5kW and 20kW. high performance efficiencies of up to — The high speed and precise MPPT Over-voltage protection type Varistor,2 for each channel c PV array ground fault detection Pre start-up Riso and Dynamic GFDI(requires floating arrays) 97.1/o. algorithm offers real time power iOutput • - This inverter includes dual input Free remote monitonng capability tracking and improved energy Anti-islanding protection _ Meets UL 1741/IEEE1547 requirements Meets UL 1741/IEEE1547 requirements section to process two strings with available with every installation.This harvesting. Over-voltage protection type Va_ris_t_or,2(L,_L2/L,-GI Varistor,2¢,-L2/L,-G) enables homeowners to view their Maximum AC OCPD Rating 35A 30A 25A 40A 35A 30A independent MPPT. — Outdoor NEMA 4X rated enclosure Maximum The high speed and precise MPPT energy production and offers installers for unrestricted use under any Maximum efficiency 97.1% algorithm offers real-time power a proactive and economic way of environmental conditions. CEC efficiency 96% 96.5% 96 5% 96% 96.5% 96 5% maintainingand troubleshootingthe User interface Graphic display Graphic display tracking and energy harvesting. — Integrated DC disconnect switch (Operating performance , Flat efficiency curves ensure high system. in compliance with international stand-by consumption <8W,,,,,S <BWp,,,s efficiency at all output levels ensuring Standards(-S Version). Night time consumption <0.6W°„° <0 6W°„, !Communication consistent and stable performance User-interface 16 characters x 2 lines LCD display _ _ across the entire input voltage and Remote monitonng(1xRS485 incl) VSN700 Data Logger(opt) output power range. iWired local monitoring(1xRS485 incl PVI-USB-RS485_232(opt) ,Environmental This outdoor Inverter has been -13°F to+140°F(-25°C to+60°C)with designed as a completely sealed unit to Ambient air operating temperature range -13°F to+140°F(-25°C to+60°C) derating above 122°F(50°C) withstand the harshest environmental Ambient air storage temperature range -4o°F to+176°F(-40°C'to+80°C) -40°F to+176°F(-40°C to+80°C) Relative humidity _ 0-100%RH condensing 0-100%RH condensing conditions. Acoustic noise emission level <50 db(A)@lm <50 db(A)®1m ILIt Power and productivity Maximum operating altitutde without derating 6560 ft(2000 m) 6560 ft(2000 m) imm2 Inverter can apply that much current-Breaker will open for a better world'”" �� 2 ABB Solar Inverters I Product flyer for PVI-5000/6000-TL-OUTD Solar inverters Additional highlights: p — RS-485 communication interface /Ann SSUN-1g ,r1 v E_r;C r 4 (for connection to laptop or data logger). i PVI-3.0/3.6/3.8/4.2-TL-OUTD - Integrated Arc Fault Detection and Ai, Interruption(-A Version). 'r--- -•-^-- ,,.( 3.0kW to 4.2kW [7L ,�._j . t I. a • { "."... ....:.°uta Sili Technical data and types Type code PVI-3.0-OUTD-US PVI-3.6-OUTD-US PVI-3.8-OUTD-US PVI-4.2-OUTD-US ' An I Mechanical specifications - ' Nominal output power 3000W 3600W 33 WD 3800W 4200W MM Maximum output power wattage 3000 3300' 3300' 3600 4000' 4000' 3300 4200' 4200' 4200 W 0 4600' 4 W W W W W W W W W W W W o Rated gnd AC voltage 208V 240V 277V 208V 240V 277V 208V 240V 277V 208V 240V 277V _ `--` - ., I Input side(DC) Number of independent MPPT channels 2 2 2 2 is.* Maximum usable power for each channel 2000W 3000W 3000W 3000W r Absolute maximum voltage(Vmax) 600V Start-up voltage(Vstart) 200V(adj 120-350V) Full power MPPT voltage range 160-530V 120-530V 140-530V 140-530V m -.-..-°� Operating MPPT voltage range 0.7 x Vstart-580V(>=90V) _ "I Maximum current(Idcmax)for both MPPT in 20A 32A 32A 32A J I parallel Maximum usable current per channel 10A 16A 16A 16A 1Maximum short circuit current limit per 12 5A 20.OA 20.OA 20.OA channel Number of wire landing terminals per channel 2 pairs ..m.M,M I Array wiring termination Terminal block,pressure clamp,AWG10-AWG4 I I Output side(AC) I i•I Ii, ' Gnd connection type 10/ Split- 10/ 10/ Split- 10/ 10/ Split- 10/ 10/ Split- 10/ 2W 0/3W 2W 2W 0/3W 2W 2W 0/3W 2W 2W 0/3W 2W rii, ''P"'' ,—:-----'7,-' Adjustable voltage range(Vmin-Vmax)(V) 183- 211- 244- 183- 211- 244- 183- 211- 244- 183- 211- 244- - 228V 264V 304V 228V 264V 304V 228V 264V 304V 228V 264V 304V i �� Pi Gnd frequency 60Hz Adjustable grid frequency range 57-60.5Hz Maximum current(Itt 14.5 14.5 12.0 17 2 16.0 16 0 16.0 16.0 18 0 20.0 20.0 20.0 - Power factor ARMS ARMs ARMS /haus ARMS ARMS0.996 ARMS ARMS ARMS ARMS ARMS Total harmonic distortion at rated power <2% This family of single-phase string The high-speed MPPT offers real- Highlights: Gnd winng termination type Terminal block,Pressure clamp,AWG10-AWG4 inverters complements the typical time power tracking and improved — Single phase and split phase output I Input protection devices - I Reverse polanty protection Yes number of rooftop solar panels energy harvesting. grid connection. -over-voltage protection type Vanstor,2 for each channel enabling home-owners to get the most The flat efficiency curve ensures high — Wide input range for increased PV array ground fault detection Pre start-up Riso and Dynamic GFDI(requires floating arrays) efficient energy harvesting for the size efficiency at all output levels allowing stringing flexibility. I Output protection devices i of theproperty. a consistent and stableperformance — The high speed and precise MPPT Anti-islanding a protection _ Meets UL 1741/IEEE1547 requirements 9 P Over-voltage protection type Vanstor,2(Lt-La/Lt-G) across the entire input voltage and algorithm offers real time power Maximum AC OCPD Rating 2OA°A,° 20A,,, 15Aq;,, 25A°„, 20A°„„ 2oA°„G 20A°„°,20Aa„° 20A„„s 25Ae„° 25A,,. 25A.,. This inverter offers a dual input output power range. tracking and improved energy 1 Efficiency i section that processes two strings The transformerless operation gives the harvesting. Mefcciency 96.9% 97% 97% 97% CEximum efficiency 96% with independent Multiple Power Point highest efficiency of up to 97.0%. — Outdoor NEMA 4X rated enclosure I Operating performance I- Tracking(MPPT). The wide input voltage range makes for unrestricted use under any Night time consumption <0.6W°„° This is especially useful for rooftop the inverter suitable to low power environmental conditions. Stand-by consumption <BW°„ I Communication installations with two different installations with reduced string size. — Integrated DC disconnect switch User-interface 16 characters x 2 lines LCD display orientations from two sub-arrays This rugged outdoor inverter has been in compliance with International Remote monitoring(1xRS485 incl.) VSN700 Data Logger(opt) oriented in different directions.(For designed to be a completely sealed Standards(-S Version). I Abient air ient air Ammboperating temperature range -13°F to+140°F with derating above 122°F(50°C) example.East and West) unit able to withstand the harshest Ambient air storage temperature range -40°F to+176°F(-40°C to+60°C) The dual input sections with environmental conditions Relative humidity 0-100%RH condensing independent MPPT enable a more Acoustic noise emission level <50 db(A)WI m 11Ill ,1 Maximum operating altitutde without derating 6560 ft(2000 m) optimal energy harvesting condition. Power and productivity 1 Capability enabled at nominal AC voltage and with sufficient DC power available for a better world'”" Pitt EP,. 2 ABB Solar Inverters I Product flyer for PVI-3 0/3 6/3 8/4 2 TL-OUTD