Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
40305-Z
�SSFFOZ1'CO Town of Southold 3/28/2016 G cf" P.O.Box 1179 53095 Main Rd ,V3) p`F Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 38179 Date: 3/28/2016 THIS CERTIFIES that the building OTHER Location of Property: 695 Theresa Dr, Mattituck SCTM#: 473889 Sec/Block/Lot: 115.-15-6 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 11/24/2015 pursuant to which Building Permit No. 40305 dated 11/30/2015 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: GAS STOVE PER MANUFACTURER'S SPECS, AS APPLIED FOR The certificate is issued to Rutkowski,Richard of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. PLUMBERS CERTIFICATION DATED Authr lard Signatu e ,, g1ffIli �o TOWN OF SOUTHOLD ,,moo r. BUILDING DEPARTMENT TOWN CLERK'S OFFICE 10 me ;oy S�r` oSOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 40305 Date: 11/30/2015 Permission is hereby granted to: Rutkowski, Richard 695 Theresa Dr Mattituck, NY 11952 To: Install gas stove as per manufacturer's specifications. • At premises located at: 695 Theresa Dr, Mattituck SCTM # 473889- Sec/Block/Lot# 115.-15-6 Pursuant to application dated 11/24/2015 and approved by the Building Inspector. To expire on 5/31/2017. Fees: CO -ALTERATION TO DWELLING $50.00 SINGLE FAMILY DWELLING -ADDITION OR ALTERATION $200.00 Total: $250.00 Bui •' g Inspector Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings, property lines, streets, and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal(S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead. 5. Commercial building, industrial building,multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings (prior to April 9, 1957) non-conforming uses, or buildings and "pre-existing" land uses: 1. Accurate survey of property showing all property lines,streets, building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy -New dwelling$50.00,Additions to dwelling$50.00,Alterations to dwelling$50.00, Swimming pool $50.00, Accessory building$50.00,Additions to accessory building$50.00,Businesses $50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy- $.25 4. Updated Certificate of Occupancy - $50.00 5. Temporary Certificate of Occupancy-Residential $15.00, Commercial$15.00 Date. —/S New Construction: Old or Pre-existing Building: ✓ (check one) Location of Property: G 9S D2 i V L rvii 1 1 7- 'C House No. Street/4 Hamlet Owner or Owners of Property: I c i i 6a-> '- 19A.6109(2z t (4 / l<c`N S I•L I Suffolk County Tax Map No 1000, Section IIS- Block IC. Lot 6 Subdivision Filed Map. Lot: Permit No. Lf0 � Date of Permit. Applicant: Health Dept. Approval: Underwriters Approval: Planning Board Approval: Request for: Temporary Certificate Final Certificate: X. (check one) Fee Submitted: $ �V Applicant Signature 4 #� #t111 TOWN OF SOUTHOLD BUILDING-DEPT. 765-1802 INSPECTION [ ] FOUNDATION-1ST [ ] ROUGH 'PLUMBING [ ] FOUNDATION 2ND [ ] ISULATION [ ] FRAMING /STRAPPING [ FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] CAULKING REMARKS: lael ee 0• DATE O3 INSPECTOR �G !� • t ti. t y 1, ��x FIELD 3 SPECQN mold. DATE 4 COM, ,NTS �: ._ ..:_ ..c'. ./. -e_Wilk, . • ..,. 0 FOUNDATION(1ST) . i'"_'"a-' . . , . , J . ( n , .+.... - ' . • • . •.' •.. �. , ;' . . . � FOUNDATION(2ND) .. ' 1. . 1 • . . .,. -1--%. . v`.. . , • • • ROUGH FRAMING& - . . , PLUMBING - pi • INSULATION PER N,Y. '.�„"""" STATE ENEIZG'Y COB _ . . • , • t,_ J ..♦ - ' . . . • • . _...._ . / .•i. . . • . . . . , .-� . Tilts~0.4 1 �.i,. T� ��,.-.•.� .. - K ,_ .-�=— 1 . 2.- 5 , .1 g' . .'V ,. . '.4 Y1 I N/A. 6.. CP*' �� , . 5 ,' g,. 2 I, • / . . . 1 th 2 . . . • . , ti. ♦ 1 . . - . " .._. . . ,, ., , .... I , .........--.......-..-...... ' V r 1 . .. - _ n )j • . TOWN OF SOUTHOLD ' BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENTDo you have or need the following;before applying? TOWN HALL ! '' Board oHealth ' SOUTHOLD, NY 11971 - - - - - - - - 4 sets•ofBuilding Plans ^Sro it,5 TEL: (631) 765-1802Planning Board approval FAX: (631) 765-9502 - - Su'rva'y'' " I SoutholdTown.NorthFork.net PERMIT NO. '76305 ..7.7--_ —_, Check , I :'-Septic-Form '' :, , , N.Y.S.D.E.C'. • I t Trustees Examined II C.O.Application I Flood Permit D 20,I Single&,Separate -,,, f Storm-Water AssessmenTl Form Contact: I Approved /) 'b. ,20 Jac. -, -• : ' - ,1 '. ,r - Mailto: ' , . - I Disapproved a/c • , 'r, , -. Phon Expiration C 3 1 ,2}0 /7 ii 70' r*H— 3 ``";r L.: • ---- Tr , ? ,ii ` ` ' '''Buildin ctor. _ - , , — 1'' lip r APPLICATION FOR BUILDING'PERMIT' " . `\-,r1 -,_____---------\\\ \\ ;i i`�` 2 3 2015 , Date / / 3 , 20 lS !' �� Nw ,!1:, j YNSTRUC-IONS--- ,; I _ __+ 1 - a.-This,application MUST\e completely filled in by`fjjpewritef'or'in`inkt• rid.Submitted to the Building Inspector with 4 sets of plans,`ur-ate=plo an to scale. Fee according to schedule. ----b:Plot plan showing location of lot and of buildings-on premises;•relationship to.adjoiningpremises or public streets or areas, and waterways. I, c. The work covered by this applicationsnay not,be commenced efore•issuo ance f.Building Permit. d. Upon approval of this application,the Building Inspector will issue a Building'Permit to the applicant Such a permit shall be kept on the premises,availables-for;inspection throughout the work., . ' - ,. t, - ,a e.No building shall be occupied or used in*Hole or io pait'Tor any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. 1 f. Every building permit shall expire if the worlS authonzecl has_r>ot commenced within 12 months after the date of issuance or has not been completed within 18'months from such:dsate:'If no zoning amendments or other regulatitons affecting the property have been enacted in the-irit'erim,-the Building Inspecto°r'zth authorize, in writing,the extension of the permit for an addition six months. Thereafter, a new permit shall be required. 1 APPLICATION IS HEREBY•MADE,•to:thel3,ui<1diri.gIlepai;tment"for the issuance of a Building Permit pursuant to the . ,. , a... 1.-,- s' � � + Building Zone Ordinance of the'Town,of-S,Otitho i,),$uff k Cotirity1 Nevis XO k?,'and•othei•'�applicable Laws,�Ordtnances,or Regulations, for the construction of buildings, additions, or alterationsor for zemoval or�'demolition as herein described.The applicant agrees to comply with all applicable laws, ordinances building',cocl'e;ihousing'cod'e;and regulations,and to admit, authorized inspectors on premises and in building for necessary inspections. ',(Sig ature of applicant or name,if a corporation) G 95 Trf€gE sr9 'ba IvE , MO iin4CK ,• • '(Mailirig:address'ofapplicant)• NY I I 95 State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician,.plumber or builder QWNE-g.„ I 1 Name of owner of premises. .,.R1,,.CF1:(9-te,b. ,.. ; , . l=".l RG49-R-C-' i gc„. 7-14-O'NSK% ' '' •(As'on the tax roll,or latest deed) Ii If applicant is a corporation, signature of duly authorized officer (Name and title of corporate officer) i, ' 1 Builders License No. I Plumbers License No. Electricians License No. ' '• • ;!' .' ,• ' 1 Other Trade's License No. ' 1. Location of land on which proposed work will be done: • House Number Street F.' • -•" '-- . " ' Hamlet Count Tax Map No. 1000 Section I )S '' Block n Lot GI 1 Subdivision Filed Map No. Lot 2. State existing use and`occupancy of premises and intended use and occupancy of proposed construction: a. Existing use an,'d,occupaticy s f N C L€ F ✓v f.w b. Intended use'arid'ocdupancy N C—� i�9 M 1 L'/' w E c—i ?iv, �'„ 3. Nature of work (check whieh;applicable):New Building -- Addition Alteration Repair Removal, • Demolition Other Work ,Tv S i 4 2 k 6-- I I iv P''`'""t,y 0 t.7 m (Description)>A, 4. Estimated Cost '- �•-j Fee (To be paid on filing this application) 5. If dwelling, number of dwelling units Number of dwelling units on each floor If garage, number of cars' - : 6. If business, commercial or mixed,occupancy, specify nature and extent of each type of use. 7. Dimensions of existing structures, if any: Front Rear Depth Height ' -Number of Stories Dimensions of same structure with alterations or additions: Front Rear Depth Height "sr;, ,,;r,.',` .,/ ,-;:, <•Nurriber of Stories 8. Dimensions of entire new construction;.Etontv,,t�t s at; Depth Height Number bfStories ' ' "' . 9. Size of lot: Front -Rear 1•,4.., 4; . ' 1 Depth 10. Date of Purchase ' . r ' 11. Zone or,use district in,which"premises,dre,situated ..1`. . .. r. 12. Does proposed coristr'uction'iviiolate anyazoning�Iaw;ordinance'orJregulation?,YES,) . NO • 13. Will lot be re-graded? YES NO Will excess fill'beFre_inoved fr'ori—P ? YES 'NO • � spremis"es let GH-1912-35 & NIiti-ar`hee,!r - ' 14. Names of Owner of premises .l?-f.4.771�0,t;t!,s1�•f,;, 14 RphorieNo., a 1 Name of Architect :_. _. .. ( ,: Address` r ii,; "' ,Phone No Name of Contractor Address i. . r.s;' ,''''.-Phone No.' .. .r111 .l... 15 a.- Is this property.within 100.feet of;a<tidal wetland;or:a s,hwater'twdtland?i`*,YES', . . •'NO' * IF YES, SOUTHOLD TOWN TRUSTEES';&1D:EC,,;TMvIITS'4AtBETREQUIRED. b. Is this property'Within 300:feet;ofa`tidal'wetldridi?.'�=YES.',. * IF YES; D:E.C. PERMITS MAY'BEREQUIRED: r`r ' :,. • • • ' ' . . .. tip' 1 r , ,---.. •' ;':; 16. Provide survey, to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point oii`property'`i's-at 10 feet or below, must provide topographical data on survey. 18. Are there any covenants•,and.restrictions with-respect to this property? * YES NO * IF YES, PROVIDEtA COPY. '., ISE -G f-f STV ve- d F itee- 9c L 3$I-,a © Q .V 2�f�9b Rte , STATE OF NEW YORK) " WESr'►+ otiprerAi 'Gtri c-Hc.�Y,lC t`7,S- , SS: °1 ci o 7 9-C)vi,gry iiZEie G-145 COUNTY OF gi,(P, Q -I - -f G f 5-5- , - q�, e oX 14 917, Sn rtrHo�)l / X765- 3 a Y'v7 6A6-61e-e-7- o r / /cove/SJ -I. , .bein,duly,swp5ri, deposes and says that(s)he is the'applicarit (Name of individual signing contract) above.named; (S)He is the U vvrv�'2 (Contractor,Agent, Corporate Officer, etc.) • . of said owner or owners, and is duly authorized to perform or have performed the said Work and to make and,file this application; that all statements contained in this application are true to the best-Of-his knowledge and'belief; and that the,work will be performed in the manner set forth-in the application filed therewith. Sy/. n to before me th's day of 1kffl' - 20 -N BETSY A. PERKINS i 1 ,L o 0r ublic . -..lic, State of n:✓ �� e • Eppy No.01 PE6130636 'Signature of Applicant Qualified in Suffolk-Cbunfx i; Commission Expires July 18 i 01-Oce__ APPROED AS NOTED DATE: FEE: ' O,ObBY: NOTIFY BUILDING DEPAR T IU, AT 765-1802 8 AM TO 4 PM FOR THE FOLLOWING INSPECTIONS: 1. FOUNDATION - TWO REQUIRED FOR POURED CONCRETE RETAIN STORM WATER RUNOFF 2. ROUGH - FRAMING & PLUMBING 3. INSULATION PURSUANT TO CHAPTER 236 4. FINAL - CONSTRUCTION MUST OF THE TOWN CODE. BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS. COMPLY WITH ALL CODES OF NEW YORK STATE & TOWN CODES AS REQUIRED AND CONDITIONS OF D SEARGL-D4011N-TRUSTES i'`:S.DEC OCCUPANCY OR USE IS UNLAWFUL WITHOUT CERTIFICATE OF OCCUPANCY r Ii All Avalon firestyles are proudly made in the S. Cypress rM GreenSmart AYALOIV Firestyles for Life 1Lit----1' Cypress TM Gas Stove Installation Guide Always refer to the Owner's Manual for installation requirements! I ii- _ _ 19-7/8"Mln _ _ .. (505mm) 2� 30-1/8"Min ` 16-5/8"Min (765mm) —w•-• — 1 f(422mm) �:� 24-3/4 Min '7 - (629mm) � fl' • I V4? • 43/4"Min .:.• , collar's 31-3/4" LJJJ III 10 22 1 4"Min (`^�• � �- .. (606mm)above \ 1 `=' V C. . r the floor lo•\,,,,, „... n :,., b3O5 (784mm) - •.44/A Weight 280 Lbs. 1 6' 4 •. i . (127 KG) t• .+fc l Stove Clearances to Combustibles - maw - , 1 dimStraight Wall Installation Corner Installation Rear Vent Installation ' ' - � ` © A=Side Wall To Unit 10"(254mm) di '" i ,, .E:11: ;.�0 B=Side Wall To Flue Center 25-1/8"(638mm) � < ' iii • C=Back Wall To Flue Center 6-7/8"(175mm) `' ii /', Qi " F \ D=Back Wall To Unit 5"(127mm) I i E=Corner To Flue Center 16-1/2"(420mm) F=CornerToUnit5"(127mm) .. - � G=Side Wall To Unit10"(27 m)H=Back Wall To Unit 8-1/4"(210mm) r1q01 .5. 4. 4 1111111). Listings and IAS(ICBG)Approval This appliance was listed by Intertek Test Labs to ANSI Z21.88 CSA 2.33-Report#100162727PRT-001. 1:�;at jell. This appliance was listed by IAS. Approved to Massachusetts Board of State Examiners of Plumbers and Gas Fitters. -s ibb: Mobile Home Requirements When the stove is installed in a mobile home,it must be bolted to the floor and the appliance grounded(use the optional blower with a grounded circuit or other suitable grounding method-current ANSI/NFPA 70 or CSA C22.1). Venting: \1 '.1" TOP VENT: REAR VENT:Use 8"(204mm)Simpson Dura-Vent Direct Vent Pro(or GS)with one of the following: _ _ i Use 6-5/8"(168mm)Simpson Dura-Vent Direct WITH NO VENT RISE Use T.I.Minimum Vent Kit D#96200317. ' i Vent Pro(or GS).Always use the high-wind cap ' ,.• #46DVA-VCH or 46DVA-CH. WITH VENT RISE: Use T.I.Rear Vent Conversion(Part#94400998. •' t �� Always use the high wind cap#58DVA-VCH or 58DVA-CH. • " Floor Protection Requirements .'I - • When the stove is installed directly on carpeting,vinyl or other combustible material other than wood flooring or a high pressure laminate wood floor,the stove must be �'-. w4 1 � • , installed on a metal or wood protection panel extending the full width and depth of the heater (Su:.k:ested Minimum Pad Size:32"wide by 20"deep). r ar'.'j'i ' " 1 Your Authorized Avalon Dealer Is Located At: CanadaIt *t44‘k i4• " ate` :� EACH FIREPLACE '� k�:� ' ' { , STOVE FIS ENER( UIDE ►i r�r. 381 8 Old Riverhead Road Westhampton Beach, NY 11978 11111110.0141., Look for theEnerGuide AVALO 631-998-0780 Gas Fireplace Energy Efficiency Rating in this brochure Firestyles for Life Based on CSA P.4.1.02 www.avalonfirestyle.com Photos and illustrations are for descriptive purposes only. We reserve the right to improve or change our products without prior notification. ,l r Dzrect Vent Gas Stove Dancing-Fyre"'and all other trademarks belong to Travis Industries,Inc. Consult the Owner's Manual for complete installation requirements. ©Copyright T.I.2010/12 Printed in the U.S.A. 98800518 !_ Giip ress GreenSmart Gas Stove • A4LoN,,GREEN SMART, Fires tyles for Life ir • 41, 4 r ; A Fireview from Anywhere in the Room Decorative Interior O tions Revolutionary GreenSmartTM System �Nor ' Options Featuring the amazing GreenSmart gas burner system and realistic Dancing-Fyre burner.The latest in energy- , , ,'. The Cypress gas stove by Avalon features sleek,very clean lines and the 4 . choice of three interiors or your unique and timeless presentation of efficient gas technology, the GreenSmart system heats the home while saving on energy usage and lowering if' 4heating bills. The real power of the GreenSmart system is the entire collection of components, controls and . 40 fire.The gentle radius-edges of the Cypress accentuate these clean lines technology features which include: iir . •• ^ and compliment a wide range of architectural styles. The open three- - 'iti M" �� sided glass design allows you to view the fire from any angle. Your +� 41" • Dancing-Fyre Burner features the most realistic • Choice of pilot ignition modes-Choose GreenSmart ;..[► if IIS , life-like fire withyour choice of three different 4 er 1 choice of the detailed 6piece logset or the driftwood fire withglass `. Pilot setting to save money or Continuous Pilot for f p < =� + +�_ interior log and stone looks. colder climates where a heated chimney is needed to ' i floor media or the river rock and glass media lets you complete the i ,,�.�' _ # ,, • Easy Heat/Flame Adjustment with a huge high- maintain the draft to ensure proper operation. ` design of this stunning stove your way. The adjustable overhead accent • <,, to-low flame turndown ratio-up to 70%.You „ ; • The standard accent light adds a glowing light r r light beautifully highlights the interior of the Cypress giving the fire choose exactly the amount of heat and flame. 11 1 ` above the logs and against the beautiful optional A .414 . - , 4” a radiance never before offered in an Avalon freestanding stove. Even Detailed Six Piece Log Set. • Comfort Control' that allows you to turn off the black enamel back whether your fire is on or off. �� i t r, when no fire is burning the accent light brings the interior to life. rear burner and just keep the front burner on. This This adjustable light is perfect as a night light or as �+• IlL allows for less heat and lets you use your gas stove a soft indirect accent light for the room. r year-round. t The Cypress is designed to be a"whole"home heater,where open floor •Three-sided fireview. Glass Area 749 sq. in. ; • Battery powered LED lit control panel automatically Front glass: 16-3/16"H x 26-1/4"W 't i plans allow. Using up to 40,000 btu's and providing heat up to 2,000 lights up when you lower the access panel so you can Side glass: 15 3/16" H x 10-9/16"W y ` „� ;; i' ; sq. Ft. The GreenSmart" intermittitant pilot and gas control system easily see the controls in a darkened room. ` . 1+1 " withthe two-stage Dancing-Fyre burner delivers an exceptionally • Optional 165 CFM Convection Blower is designed ''r,� ,r r _ if.'„,e' • Built-in battery backup allows you to operate ' • i to enhance the transfer of the natural radiant and or - energy efficient turn down rate of up to 70% on NG and 82% on LP. f. - = ' ..... ... . _- L your gas stove during power outages.The back-up - .l 44 .,,�.g _' �` .- move the convective heat from the stove more ! :rt. 1,( The GreenSmart system provides precise control over the amount of system will automatically switch back to AC when the power comes back on. efficiently into your home. _r .� heat you use. For the coldest nights or the just chilly enough to light4S "„ ., your fire kind of nights your fire can be custom adjusted to be just right. Dri Driftwood Fire Art withglass floor media. `"`GreenSmart Remote Option Glass media comes with your choice of reflective The Cypress gas stove can be installed and operated with a wall thermostat or basic remote control which offers ® a Platinum, Bronze or Cobalt Blue colors. P +?=�_ " OFF and thermostat controls.But for the ultimate in hands-free operation consider adding the optional GreenSmart !j � Radiant and Convective Heating f,,. air,,,' Remote. This convenient remote gives you the ability to control all the functions of the stove from one easy-to-use iiii ..1:-.....''` i*• The Cypressprovides heat in two ways.Radiant heat comes off the stove in hand-held remote with the exception ofyourpilot settingand accent light.The GreenSmart Remote givesyou the YP Y P �''Air "MF f .41P... 4-, '''.7.,..,44."-.... de„,, straight lines.Think of warming your backside around a campfire. RadiantRito„. choice to run the stove in manual mode,set to the traditional thermostat mode or in the"Smart Thermostat Mode". - a x heat gives the room gentle warmth and comfort to the room. Convection In"Smart Mode"the flame will modulate up/down as opposed to shutting OFF/ON like normal thermostats,thus conserving fuel and maximizing heating ability while extending the viewing pleasure of the fire. The end result—an • - heat works like a forced-air furnace. The built in heat exchanger harnesses "�lr` r elegant,smarter and greener way to heat the home. •mot,0 - `` 4 the radiant energy from the fire and transfers it to the air as it naturally 111 4 '� 4401141. 1 11 -lip ' circulates around the firebox.The super-heated air is then delivered not just ” Flexible Installation Choices liO 11' into the the room but throughout the house through natural convection. — i��ii�i The Cypress gas stove features direct vent technology ' ., The addition of the 165 CFM blower makes an excellent option for the stove �R '""` P and can be vented vertically or horizontally adding i I: . -;,, River Stones with glass floor media. 1 II - by increasing the flow of air around the firebox.This makes it easier to move location flexibility,and in many cases lowering installation = i p .*, Glass media comes with your choice of reflective 'i; the heat out of the room and into the rest of the house. Platinum, Bronze or Cobalt Blue colors. cost.You can even install the Cypress on a hearth in front �' :j`• •.J of an existing fireplace and vent it up the chimney. • K 44 �: 144b, i y Maximum Minimum The Cypress does not require any type of hearth padril 11 ii. ' •�i�� Ivo BTU In ut/Hr. Heating Capacity* AFUE Efficiency Canadian P.4.1 Efficiency BTU Input/Hr. in many installations, including wood flooring. The } 40,000(NG&LP) 11,900(NG) 7,400(LP) Up to 2,000 sq.ft.with fan Up to 72.6%NG&74.2 LP Up to 70.4%NG-72.7%LP Cypress is approved for close clearances to the back .� 4 � , ,. , 1. +t r '(;,u appliance performance can be affected by negative pressure in the home and by prevailing atmospheric conditions.Contact local building or flue officials about resmctions and installation requirements in s our dica. wall without expensive heat shields.This saves valuable # Overall efficiency measured with maximum flue configuration.Heating capacity shown with blower. floor space and eliminates the requirement for expensive Top Vent Rear Vent __Hearth # non-combustible wall protection. Installation Installation Installation 4 w e