Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
40272-Z
,,,s0CF'ti est Town of Southold 3/9/2016 ,� , P.O.Box 1179 {o x 53095 Main Rd %,��� $�'�l r Southold,New York 11971 r CERTIFICATE OF OCCUPANCY No: 38138 Date: 3/9/2016 THIS CERTIFIES that the building WIRELESS COMMUNICATION SYSTEMS Location of Property: 21855 CR 48, Cutchogue SCTM#: 473889 Sec/Block/Lot: 96.-1-19.1 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 6/30/2015 pursuant to which Building Permit No. 40272 dated 11/16/2015 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: modification to an existing wireless communications facility for AT& T as applied for. The certificate is issued to Junge,Arthur of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. PLUMBERS CERTIFICATION DATED ...-- , , ‘ Auth d Signatu sv ntrTOWN OF SOUTHOLD ,01 cam BUILDING DEPARTMENT TOWN CLERK'S OFFICE le" .z' SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 40272 Date: 11/16/2015 Permission is hereby granted to: Junge, Arthur 418 Moulton Hill Rd Lyman, NH 03585 To: construct a wireless modification to an existing wireless communications facility. At premises located at: 21855 CR 48, Cutchogue SCTM # 473889 Sec/Block/Lot# 96.-1-19.1 Pursuant to application dated. '6/30/2015 and approved by the Building Inspector. To expire on 5/17/2017. . Fees: WIRELESS COMMUNICATIONS -MODIFICATIONS $500.00 CO -COMMERCIAL $50.00 al: $550.00 Building Ins Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings,property lines,streets,and unusual natural or topographic features. 2. Final Approval from Health Dept.of water supply and sewerage-disposal(S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1%lead. 5. Commercial building,industrial building,multiple residences and similar buildings and installations,a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings(prior to April 9,1957)non-conforming uses,or buildings and"pre-existing"land uses: 1. Accurate survey of property showing all property lines,streets,building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant.If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00,Alterations to.dwelling$50.00, Swimming pool$50.00,Accessory building$50.00,Additions to accessory building$50.00,Businesses$50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy-$.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy-Residential$15.00,Commercial$15.00 Date. New Construction: Old or Pre-existing Building: x (check one) Location of Property: 21855 County Rd 48 Cutchague House No. Street Hamlet Owner or Owners of Property: Arthur V,lunge Suffolk County Tax Map No 1000,Section 96 Block 1 Lot- 19.1 Subdivision hh �! Filed Map. Lot: Permit No. L ) d Date of Permit. Applicant: Health Dept.Approval: Underwriters Approval: - Planning Board Approval: Request for: Temporary Certificate Final Certificate: x (check one) Fee Submitted: $ 50 / Applicant Signature ,,,,,,,,, D/ „ cf.:�pF SO(/T�ol * * -, , ,OUNi`„;;�' TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLUMBING [ ] FOUNDATION 2ND [ ] 1N LATION [ ] FRAMING /STRAPPING [ FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLA ON [ ] CAULKING REMARKS: 6 G-ter&' DATE 19-2--/A-3/6, INSPECTOR- 9-4 .-• 300 Broadacres Drive; Of t, Bloomfield,NJ 07003 B Tel (201)571-0768 Fax: (201)5710650 February 03,2016 Town of Southold `-`1 j Building Department ' Town HaII '��� I J Southold,NY 11971 , 1.1. FEB 2 3 2016 1 L 1 Subject: Professional Engineer's Certification LetterL - --- r , -__ __ t AT&T Site ID#: NYCENY1027 - AT&T USI D#: 47250 AT&T Site Name: CUTCHOGUE Town of Southold Permit Number: 40272 County Tax Map 473889,Section: 96,Block: 0001,Lot: 019.1 21855 County Road 48,Cutchogue,NY 11935 Latitude: N 41°01'46.42";Longitude: W 72'29'50.06" To Whom It May Concern: This letter is to certify that Bechtel Associates Professional Corporation visited the AT&T telecommunications facility located at 21855 County Road 48,Cutchogue,NY 11935 on December 21,2015;on behalf of AT&T, for the purpose of close out documentation for LTE Building Permit#40272 and to certify that the proposed installation conforms to the Building Permit and Town-approved Construction Drawings(Sheets T01 through E04,Rev 1 dated June 12,2015) The installation conforms to the Town-approved Construction Drawings,all applicable Town and New York State Building Codes. dtoF...-: Nei) Respectfullysubmatteip,.' 43 0 ,OG),®'S„ill ' Iliyassou Moutairou, II eAiWegiji lc g I NY License#091807-1 ,; '.f;- .° `' - Bechtel Associates Prof-i"".....7i,Ettgot i 7182040189 14:06:46 03-08-2016 1'/1 1 �. s •s I Odyssia Global Communications, Corp. 25-72 Borough Place Tel.: (718)932-4819 N„t Woodside N.Y.11377 Fax.: (718)204-0189 SSM - Subject: No Electrical Work I would like to notify to the Town of Southold Building Department that no any electrical work has been performed for AT&T cell site located at 21855 County Road 48 under Permit no: 40272. Thanks, Samar Koirala Ph. (530)-665-3697 —13) 7CEDVE MBAR - 8 2016 did BUILDING DEPT. TOWN OF SOUTHOLD OlUseistsamafflesktopletter Head.doc FIELD IN'SPECTXQN I E?OI - D COIv[ •ENTS FUND,A. OI�i(1ST} SO • v 4k • • ._. . • , d • . . FOUNDATION(2M). a ' '� ' .,. , ,. . , . , , . . . = O ,.._...... .d . \ .. cp � ( v ' �n ROUGH FRAMING& ._....,,� . H PLUMBING ----�--- , ....— . . . _, .. ,. . . �y. . l:0y '. ,. .'��-. '• • ' •y, , • • • 1. INSULATION'PERN.Y. ---'' . ' . . .. , H STATE ENERGY CODE • , • • • . d . , - ._. �..r._ . . . . / . eflreft•-• •1440°-swe-k ',I, ilk y ' --, . 40 2'''A3' /0 0 04 A.C• 0.." ' ' '141,17-r• ..r FINAL i /' L• 1 . •'b i ' 0 • iiVV4 TS , . .6. Nib tili ; • i! n , , , J q, ryo , , 0 e>fy-, 0,o.04 In tiv\ uA .. ,. _ ,, . , .. , „, . . ._. .e. r, t i .2 . , . 4-h." P ..v, . ______ , . ?. . . .. • ... _, : .,. • ....... , . , . 0 ., . . . . . , . ".. _. .... . . .., . . .. , . . _ ......... . ......, z . . . . . . . . ..r.. ..... ., . TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD,NY 11971 4 sets of Building Plans TEL:(631)765-1802 Planning Board approval FAX:(631)765-9502 I Survey SoutholdTown.NorthFork.net PERMIT NO. O a 7-�-� Check Septic Form N.Y.S D.E.C. Trustees C O.Application Flood Permit Examined 20 Single&Separate Contact:Storm-Water Assessment Form Approved 20 Mail to• f; 1 u Disapproved a/c - f I' - P e: � I i Expiration ,20 j I 1 LI JUN 3 0 2015 L4 Building Inspecto APPLICATION FOR BUILDING PE's•': "" : , '='1 IG Date , INSTRUCTIONS a This application MUST be completely filled in by typewriter or m ink and submitted to the Building Inspector with 4 sets of plans,accurate plot plan to scale.Fee according to schedule. b.,Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas,and waterways c.The work covered by this application may not be commenced before issuance of Buildmg Permit. d.Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant.Such a permit shall be kept on the premises available for inspection throughout the work. e No building shall be occupied or used in whole or m part for any purpose what so ever until the Buildmg Inspector issues a Certificate of Occupancy. f.Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date.If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize,in wnting,the extension of the permit for an addition six months.Thereafter,a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk County,New York,and other applicable Laws,Ordinances or Regulations,for the construction of buildings,additions,or alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code,housing code,and regulations,and to admit authorized inspectors on premises and in building for necessary inspections. New Cingular Wireless PCS,LLC (Signature of applicant or name,if a corporation) 3B Prospect PI,Madison NJ 07940 (Mailing address of applicant) State whether applicant is owner,lessee,agent,architect,engineer,general contractor,electrician,plumber or builder Applicant is Lessee Name of owner of premises Arthur V Junge (As on the tax roll or latest deed) If applicant is a corporation,signature of duly authorized officer New Cmqqular Wireless CS,LLC Ryan BaTey as agent for Applicant (Name and title tiVOOVOt8VONXik) Builders License No. Plumbers License No. Electricians License No. Other Trade's License No. 1. Location of land on which proposed work will be done: 21855 County Road 48 Cutchague House Number Street Hamlet County Tax Map No.1000 Section 98 Block 1 Lot 19 1 Subdivision Filed Map No. Lot 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy Commercial building and public utility wireless telecommuncations facility b. Intended use and occupancy public utility wireless telecommunications facility 3. Nature of work(check which applicable):New Building Addition Alteration Repair Removal Demolition Other Work modification of existing telecommunications site (Description) 4. Esti>,nated Cost $25,000 Fee (To be paid on filing this application) 5. If dwelling,number of dwelling units N/A Number of dwelling units on each floor If garage, number of cars 6. If business,commercial or mixed occupancy,specify nature and extent of each type of use. 7. Dimensions of existing structures,if any:Front Rear Depth Height Number of Stories Existing 108 5'monopole and existing 18'4'x 10'equipment area Dimensions of same structure with alterations or additions: Front Rear Depth Height Number of Stories no change 8. Dimensions of entire new construction:Front Rear Depth Height Number of Stories no change 9. Size of lot:Front Rear Depth 10.Date of Purchase 4/6/1987 Name of Former Owner Timothy Scott Gray 11.Zone or use district in whichpremises are situated Light Industrial District 12.Does proposed construction violate any zoning law,ordinance or regulation?YES NO x 13.Will lot be re-graded?YES NO x Will excess fill be removed from premises?YES NO 14.Names of Owner of premises Arthur V Junge Address 418 Moulton Hill Rd,Lyman NFPhone No. 603-838-8982 Name of Architect Address Phone No Name of Contractor Bechtel Infrastructure and Power Corp Address 300 Broadacres Dr,#250 Phone No. 201-571-0629 Bloomfield NJ 0/003 15 a.Is this property within 100 feet of a tidal wetland or a freshwater wetland?*YES NO x *IF YES,SOUTHOLD TOWN TRUSTEES&D.E.C.PERMITS MAY BE REQUIRED. b.Is this property within 300 feet of a tidal wetland?*YES NO *IF YES,D.E.C.PERMITS MAY BE REQUIRED. 16.Provide survey,to scale,with accurate foundation plan and distances to property lines. 17.If elevation at any point on property is at 10 feet or below,must provide topographical data on survey. 18.Are there any covenants and restrictions with respect to this property?*YES NO x *IF YES,PROVIDE A COPY. J a/Joy STATE OF NEW YIIRK) SS: COUNTY OF ) � Ica 72, being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)He is the 7/ €' (ontractor,Agent,Corporate Officer,etc) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application; that l \\,``�GK��f �'flerfolrmed in the manner set forth in this application the application fled therewith.hhhe to the best of his knowledge and belief;and that the work will be ,t On....... �QTAR1:••. Sif%orn to before me this ... :Z 5- day of "'4 20 G l9 t My Comm.Expirrs Dec.1,201 bb6/.- -AMP' No 2353073 y IOW N 11/ otary abbeture of Applicant "7 •••°°UBL\G•• q' ',, Op NE",�lE.\' - .;E LOCATION: „ ' ”' MAILING ADDRESS: 1 own Hall Annex oioi1A®F SO (/7 P.O. Box 1179 54375 State Route 25 �'I ®• ®l® Southold,NY 11971 \cor.Main Rd. &Youngs Ave.) � • Southold, NY Zig Afg Telephone: 631 765-1938 www.southoldtownny.gov ,. ZirCOUNTi rig. PLANNING BOARD OFFICE TOWN OF SOUTHOLD MEMORANDUM To: Michael J. Verity, Chief Building Inspector From: Heather M. Lanza, AICP, Planning Director Date: November 13, 2015 Re: Planning Department Report New Cingular Wireless at Junge SCTM#1000-96.-1-19.1 21855 County Road 48, Cutchogue As an addendum to the attached SPUD, the Planning Department has conducted a review of the proposed modifications pursuant to §280-74 B.(2), and has received a report from our Wireless Technical Consultant, Cityscape, Inc. (see attached report). We have the following recommendations for this application: 1. The proposed modifications and up-grades are in compliance with the General Requirements of§280-70, therefore, we recommend a Building Permit be issued for this application in accordance with the Structural Analysis Report, dated March 9, 2015; 2. The Building Permit must state the following: a. All of Applicant's existing and new feed lines/cables shall be installed inside the monopole structure; b. All feed line access ports shall be sealed to prevent access by any birds or other wildlife; c. The facility shall remain secured and protected from unauthorized personnel. Thank you for your cooperation. !C'ackhaul Acquisition Services LLC June 25, 2015 Building Inspector Town of Southold 54375 Main St Southold NY 11971 RE: Building Permit Application Applicant: New Lingular Wireless PCS, LLC ("AT Property Owner: Arthur V Junge j Lr Property YAddress: 21855 CountyRd 48, Cutchague NY I , Assessors' Info: 96-1-19.1 I JUN 3 0 2015 Tower Owner: AT&T Dear Building Inspector: 0',' 'f;;i Enclosed please find an antenna permit application for AT&T at 21855 County Road 48, Catchague NY. This package includes the following items 1. Signed and notarized permit application 2. Signed Certificate of Occupancy application 3. 4 sets of plans (Survey included in plans) 4. $550 check for the permit application fee 5. Certificates of insurance from the General Contractor 6. 6409 Letter Should you have any questions please do not hesitate to contact me at(856)625-1596 or via email at ryan@backhaulacquistion.com Sincerely, Ryan G. Bailey Backhaul Acquisition Services 3B Prospect PI Madison, NJ 07940 856-62.5-1596 973-215-2940 Fax Ryan@backhaulacquisition.com 641 Shunpike Rd Suite 117 Chatham,NJ 07928 856.625.1596 Office 973.215.2940 Facsimile June 25, 2015 Building Inspector Town of Southold Town Hall Southold NY 11971 RE: Building Permit Application Applicant: New Cingular Wireless PCS,LLC ("AT&T") Property Owner: Arthur V Junge Property Address: 21855 County Rd 48, Cutchague NY Assessors' Info: 96-1-19.1 Tower Owner: AT&T Dear Building Inspector: New Cingular Wireless PCS, LLC ("AT&T") seeks a building permit for the installation of transmission equipment on the existing tower and within the existing equipment compound at the above-referenced property. Your building application form along with the applicable application fee of$550 is submitted with this letter. Introduction to Section 6409 AT&T applies for the building permit under Section 6409 of the federal Middle Class Tax Relief and Job Creation Act of 2012, signed into law by the President on February 22, 2012.1 While your town retains discretionary zoning review over the construction of new towers, simple collocations and/or equipment upgrades such as reflected in this application must now be approved with the issuance of a building permit. The new law provides that: "a State or local government may not deny, and shall approve, any eligible facilities request for a modification of an existing wireless tower or base station that does not substantially change the physical dimensions of such tower or base station." (Emphasis added.) The federal law defines an"eligible facilities request"as"(A) collocation of new transmission equipment; (B) removal of transmission equipment; or(C) replacement of transmission equipment."The new law authorizes the immediate installation of these eligible facilities to help improve the economy, create jobs, and speed the deployment of the services they provide. A complete copy of Section 6409 of this new federal law is enclosed. 1 See February 2012 link located at http://www.whitehouse.gov/briefing-room/signed-legislation. Page 2 Section 6409 Benefits Your Community and has been Embraced Across the Country Acknowledging that there is no valid basis in zoning to deny an application such as the one proposed here,municipalities across the nation have approved installations under Section 6409 with the issuance of a building permit. With the new federal law providing guidance, municipalities have been quick to embrace the benefits of a streamlined administrative review for simple collocations and equipment modifications. Unlike the construction of a new tower, simple collocations and/or equipment modifications such as this one have been quickly approved to expedite the deployment of wireless broadband. Municipalities want their residents, businesses and emergency responders to benefit from improved wireless coverage and the latest technology(4G LTE for the iPhone 5 and other handsets) as quickly as possible. AT&T's Application Must Be Approved AT&T's application must be approved under this new federal law because the proposed installation involves"a modification of an existing wireless tower or base station that does not substantially change the physical dimensions of such tower or base station." AT&T's current facility consists of three antennas at a centerline height of 70' on an existing 108.6' tower. AT&T also has an equipment shelter located at the bottom of the pole As shown on the enclosed plans prepared by Bechtel Engineering dated 6/12/15,AT&T's proposed installation consists principally of the following elements: 1) On the tower,three panel antennas to be swapped out. Total of nine antennas mounted at an antenna centerline height of 70', with associated remote radio heads,tower-mounted amplifiers (TMAs), a surge arrestor, cables and fiber; and 2) In the Existing Compound: Existing cabinets to remain AT&T's installation will not increase the height of the tower nor the dimensions of the equipment compound. The installation is similar to others on the existing tower. As a result,the installation"does not substantially change the physical dimensions of such tower or base station." The installation will enhance wireless communication services to the community and will enable users to access a state-of-the-art, fully digital system for voice communications, messaging, and data transmission and reception. AT&T respectfully requests that the building permit be issued as soon as possible so that AT&T can proceed with this installation immediately. If we can provide any further information regarding this application,please let us know. 'c Page 3 Respectfully, Ryan G Bailey c: [Network Manager] (by email) ' Jay Perez (by email only–jay.perez@att.com) enclosures: Building Permit Application Form Construction Drawings Structural Analysis Tax Relief Act- Section 6409 Insurance Certificate FCC Public Notice dated January 25, 2013 47 USC 1455 Middle Class Tax Relief and Job Creation Act of 2012 SEC. 6409. WIRELESS FACILITIES DEPLOYMENT (a)FACILITY MODIFICATION.— (1)IN GENERAL.—Notwithstanding section 704 of the Telecommunications Act of 1996 (Public Law 104-104) or any other provision of law, a State or local government may not deny, and shall approve, any eligible facilities request for a modification of an existing wireless tower or base station that does not substantially change the physical dimensions of such tower or base station. _` \. Page 4 (2) ELIGIBLE FACILITIES REQUEST.—For purposes this subsection,the term "eligible facilities request" means any request for modification of an existing wireless tower or base station that involves— (A) collocation of new transmission equipment; (B)removal of transmission equipment; or (C) replacement of transmission equipment. (3) APPLICABILITY OF ENVIRONMENTAL LAWS.Nothing in paragraph(1) shall be construed to relieve the Commission from the requirements of the National Historic Preservation Act or the National Environmental Policy Act of 1969. Bunch, Connie From: Cummings, Brian A. Sent: Monday, March 07, 2016 10:39 AM To: Bunch, Connie Subject: New Cingular Wireless @ Junge (21855 CR 48 Cutchogue) Hi Connie, I have completed a site inspection for the above referenced wireless communication upgrades/modifications and can confirm that the installation was completed as approved in the SPUD memo dated November 13, 2015.Samar Koirala contacted me about obtaining a CO for the site, I'm not sure if he has already contacted you regarding the same. Please let me know if there is anything else you need from us. Thank you Brian Brian A. Cummings, Planner Southold Town Planning Department 53095 Route 25 P.O. Box 1179 Southold, NY 11971 Phone: (631)765-1938 E-mail: brian.cummings@town.southold.ny.us 1 DATE(MM/DD/YY) CERTIFICATE OF INSURANCE 06/10/15 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER IMPORTANT:If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must be endorsed If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require en endorsement A statement on this certificate does not confer nghts to the certificate holder in lieu of such endorsement(s) PRODUCER PHONE(A/C No.Ext)• 415-486-7436 FAX(A/C,No.) 415-486-7062 AON RISK INSURANCE SERVICES WEST,INC. E-MAIL 199 Fremont Street,Suite 1500 ADDRESS PRODUCER San Francisco,CA 94105 CUSTOMER ID# INSURER(S)AFFORDING COVERAGE NAIC# INSURED INSURER A: INSURANCE COMPANY OF THE STATE OF PA BECHTEL INFRASTRUCTURE AND POWER CORPORATION INSURER B: INSURER C INSURER D. INSURER E INSURER F: COVERAGES THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS,EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS INSR ADDL SUER POLICY EFF POLICY EXP LTR TYPE OF INSURANCE INSR WVD POLICY NUMBER (MM/DD/YY) (MM/DD/YY) LIMITS GENERAL LIABILITY EACH OCCURRENCE $1,000,000 A ® COMMERCIAL GENERAL LIABILITY X GL 5610594 04/01/15 04/01/16 DAMAGE TO RENTED PREMISES ❑CLAIMS MADE ®OCCUR (Each occurrence) $100,000 ❑ MED EXP(Any one person) $5,000 GEN'LAGGREGATE LIMIT APPLIES PER: PERSONAL&ADV INJURY $1,000,000 ❑POLICY El PRO- ❑ LOC JECT GENERAL AGGREGATE $1,000,000 PRODUCTS-COMP/OP AG $1,000,000 AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT $ ❑ANY AUTO (Each accident) ❑ALL OWNED AUTOS BODILY INJURY(Per person) $ ❑SCHEDULED AUTOS ❑ HIRED AUTOS BODILY INJURY(Per accident) $ ❑ NON-OWNED AUTOS PROPERTY DAMAGE $ (Per acddent) 0 UMBRELLA LIAB 0 OCCUR EACH OCCURRENCE $ El EXCESS LIAB 0 CLAIMS-MADE AGGREGATE $ — ❑ DEDUCTIBLE $ ❑ RETENTION $ WORKERS COMPENSATION WC STATU- DTH- $ AND EMPLOYERS'LIABILITY N/A TORY LIMITS ER ANY PROPRIETOR/PARTNER/EXECUTIVE E L EACH ACCIDENT $ OFFICER/MEMBER EXCLUDED? (Mandatory in NH) YES NO E L DISEASE-EA EMPLOYEE $ If Yes,describe under ❑ 0 DESCRIPTION OF OPERATIONS below EL DISEASE-POLICY LIMIT $ DESCRIPTION OF OPERATIONS/LOCATIONSNEHICLES License/Permit CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE TOWN OF SOUTHOLD THE EXPIRATION DATE THEREOF,NOTICE WILL BE DELIVERED IN 53095 Route 25 ACCORDANCE WITH THE POLICY PROVISIONS. P.O.Box 1179 AUTHORIZED REPRESENTATIVE Southold,NY 11971 001 • southold doc (BJ 25736) (EOC 04,'01/16) (PN) STATE OF NEW YORK WORKERS'COMPENSATION BOARD CERTIFICATE OF NYS WORKERS' COMPENSATION INSURANCE COVERAGE la.Legal Name&Address of Insured(Use street address only) lb.Business Telephone Number of Insured 301-228-6129 Bechtel Infrastructure and Power Corporation 5275 Westview Drive ic.NYS Unemployment Insurance Employer Frederick,MD 21703 Registration Number of Insured 48-05771-4 id.Federal Employer Identification Number of Insure d Work Location of insured(Only required Ifcoverage Is specifically or Social Security Number limited to certain locations in New York State, i.e., a Wrap-Up 20-5784228 Policy) 2.Name and Address of the Entity Requesting Proof of 3n. Name of Insurance Carrier Coverage(Entity Being Listed as the Certificate Holder) Insurance Company of the State of Pennsylvania 3b.Policy Number of entity listed in box"la" Town of Southold WC 493-42-532 53095 Route 25 P.O.Box 1179 3c. Policy effective period Southold,NY 11971 04/01/2015 to 04/01/2016, 3d. The Proprietor,Partners or Executive Officers arc included. (Only check box ifall partncrstofrcers Included) 0 all excluded or certain partners/officers excluded. This certifies that the insurance carrier indicated above in box"3" insures the business referenced above in box"la" forworLers' compensation under the New York State Workers'Compensation Law.(To use this form,New York(NY)must be listed under Rena 3A on the INFORMATION PAGE of the workers'compensation insurance policy). The Insurance Carrier or its licensed agent will send this Certificate of Insurance to the entity listed above as the certificate holder in box"2". The Insurance Carrier will also notes the above certificate irolderwithin 10 days IF a policy is canceled due to nonpayment ofprent hans or within 30 days IF there are reasons other than nonpayment of premhans that cancel the policy or eliminate the insured from the coverage indicated on this Certificate. (These notices may be sent by regular mail) Otherwise,this Certificate is valid for one year q i'er this form is approved by the insurance carrier or its licensed agent,or until the policy expiration date listed in box"3c",whichever is earlier. Please Note:Upon the cancellation of the workers' compensation policy indicated on this form,if the business continues to be named on a permit,license or contract issued by a certificate holder,the business must provide that certificate holder with a new Certificate of Workers'Compensation Coverage or other authorized proof that the business is complying with the mandsxtory coverage requirements of the New York State Workers'Compensation Law. Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier refere aced above and that the named insured has the coverage as depicted on this form. Approved by: Thomas Morrissev /Print name of authorized representative or licensed agent of insurance carrier) Approved roved � G s 6� (Signature) (Date) Title: Vice President Senior Underwriter Telephone Number of authorized representative or licensed agent of insurance carrier- 212-770-7000 Please Note: Only insurance carriers and their licensed agents are authorized to issue Form C-105.2.Insurance brokers are.NOW authorized to issue it. C-I05.2(9-07) www.wcb.state.ny.us STATE OF NEW YORK WORKERS'COMPENSATION BOARD CERTIFICATE OF INSURANCE COVERAGE UNDER THE NYS DISABILITY BENEFITS LAW PART 1.To be completed by Disability Benefits Carrier or Licensed Insurance Agent of that Carrier la.Legal Name and Address of Insured(Use street address lb.Business Telephone Number of Insured only) 301-228-6129 lc.NYS Unemployment Insurance Employer Registration Bechtel Infrastructure and Power Corporation Number of Insured 5275 Westview Drive Frederick,Maryland 21703 ld.Federal Employer Identification Number of Insured or Social Security Number 20-5784228 2.Name and Address of the Entity Requesting Proof of 3a.Name of Insurance Carrier Coverage(Entity Being Listed as the Certificate Holder) CIGNA LIFE INSURANCE COMPANY OF NEW YORK Town of Southold 3b.Policy Number of entity listed in box"la": 53095 Route 25 NYD074559 P.O.Box 1179 Southold,New York 11971 3c.Policy effective period: 01/01/2015 to 01/01/2016 4.Policy covers: ®a.All of the employer's employees eligible under the New York Disability Benefits Law L ib.Only the following class or classes of the employer's employees: Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has NYS Disability Benefits insurance coverage as described above. verffily 411(4/gft Date Signed March 20,2015 By (Signature of insurance carrier's authonzed representative or NYS Licensed Insurance Agent of that insurance carrier) Telephone Number 1.866-761-4236 Title Underwriting Director IMPORTANT: If box"4a"is checked,and this form is signed by the insurance carrier's authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE.Mail it directly to the certificate holder. If box"4b"is checked,this certificate is NOT COMPLETE for purposes of Section 220,Subd.8 of the Disability Benefits Law.It must be mailed for completion to the Workers'Compensation Board,DB Plans Acceptance Unit,328 State Street,Schenectady,New York 12305. PART 2.To be completed by NYS Workers'Compensation Board(Only if box"4b"of Part 1 has been checked) State Of New York Workers'Compensation Board According to information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS Disability Benefits Law with respect to all of his/her employees. Date Signed By (Signature of NYS Workers'Compensation Board Employee) Telephone Number Title Please Note:Only insurance carriers licensed to write NYS disability benefits insurance policies and NYS licensed insurance agents of those insurance carriers are authorized to issue Form DB-120.1.Insurance brokers are NOT authorized to issue this form. DB-120.1(12-13) L PROJECT DESCRIPTION &416/ Iliiiiiiii!.A0 * MODIFICATION TO EXISTING TELECOM FACILITY COMPRISING OF EQUIPMENT, ANTENNA AND ASSOCIATED CABLES. a) L _.„41111Nimill m'i "'"81111101..." m L 0 D ,,,, ,,,,.i d,, ,,.. u PROJECT INFORMATION • E SITE ADDRESS: 21855 COUNTY ROAD 48 s CUTCHOGUE, NY 11935 (02 E [\ U ER Kr]YC E Hystil TD _ s PROPERTY OWNER: CROWN COMMUNICATION, NEW YORK INC. .,uL e m SITE #806579 CO a APPLICANT ADDRESS: NEW CINGULAR WIRELESS PCS, LLC ("AT&T")0 (.4.1/4"; 11 Ti E N A ® It C 3 ONE AT&T WAY BEDMINSTER, NJ 07921 VICINITY MAP APPLICABLE BUILDING CODES AND STANDARDS o JURISDICTION: TOWN OF SOUTHOLD FROM BEDMINSTER,NJ: -° o PROPERTY TAX ID: SECTION 96, BLOCK 1 , LOT 19.1 HEAD SOUTH, SLIGHT RIGHT ONTO AT&T WAY, MERGE ONTO US-202 S/US-206 S, TURN LEFT ONTO SUBCONTRACTOR'S WORK SHALL COMPLY WITH ALL APPLICABLE NATIONAL, STATE, AND LOCAL `V ZONING DISTRICT: LIGHT INDUSTRIAL SCHLEY MOUNTAIN RD, TAKE THE INTERSTATE 287 N SLIP ROAD, MERGE ONTO 1-287 N, TAKE EXIT CODES AS ADOPTED BY THE LOCAL AUTHORITY HAVING JURISDICTION (AHJ) FOR THE LOCATION. LATITUDE: N 41' 1 ' 46.42" (NAD 83) 41A FOR INTERSTATE 80 E/SMITH ROAD TOWARDS U.S. 46/NEW YORK CITY, KEEP LEFT, FOLLOW SIGNS THE EDITION OF THE AHJ ADOPTED CODES AND STANDARDS IN EFFECT ON THE DATE OF . 5 FOR 1-80 E/NEW YORK CITY KEEP LEFT TO CONTINUE TOWARDS 1-80 E KEEP LEFT AT THE FORK, CONTRACT AWARD SHALL GOVERN THE DESIGN. LONGITUDE: W 72' 29' 50.06" (NAD 83) FOLLOW SIGNS FOR 1-80 E/PATERSON/NEW YORK AND MERGE ONTO 1-80 E, KEEP LEFT AT THE FORK o o ELEVATION: 58'± AMSL (NAVD 88) TO CONTINUE ON 1-80 EXPRESS E, CONTINUE ONTO 1-95 EXPRESS N, CONTINUE ONTO 1-95 N, BUILDING CODE: BUILDING CODE OF NEW YORK STATE - 2010 CURRENT USE: TELECOMMUNICATIONS FACILITY PARTIAL TOLL ROAD, ENTERING NEW YORK, KEEP LEFT TO STAY ON 1-95 N, KEEP RIGHT AT THE FORK c a TO CONTINUE ON CROSS BRONX EXPY, FOLLOW SIGNS FOR INTERSTATE 295 S THROGS NECK BR, ° E PROPOSED USE: TELECOMMUNICATIONS FACILITY ELECTRICAL CODE: NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) 70-NATIONAL ELECTRICAL CODE oCONTINUE ONTO 1-295 S, PARTIAL TOLL ROAD, TAKE EXIT 8 FOR CROSS IS PKWY S, MERGE ONTO (NEC) - 2008 o 2 CROSS ISLAND PKWY, TAKE EXIT 30E TO MERGE ONTO 1-495 E/LONG ISLAND EXPY TOWARDS EASTERN a Cr) LONG ISLAND, TAKE EXIT 73 ON THE LEFT TOWARDS GREENPORT/ORIENT/SUFFOLK COUNTY 58, KEEP FIRE/LIFE SAFETY CODE: FIRE CODE OF NEW YORK STATE - 2010 o °DRAWING INDEX REV LEFT AND MERGE ONTO OLD COUNTRY RD, AT THE TRAFFIC CIRCLE, TAKE THE 2ND EXIT AND STAY ON OLD COUNTRY RD, TURN LEFT ONTO NORTHVILLE TURNPIKE, TURN RIGHT ONTO SOUND AVE, CONTINUE LIGHTNING PROTECTION CODE: NFPA 780-2008 LIGHTNING PROTECTION CODE 15. ° NYCENY1027 -T01 TITLE SHEET 1 STRAIGHT ONTO MIDDLE RD, MAKE A U-TURN AT COX LN, DESTINATION WILL BE ON THE RIGHT. SUBCONTRACTOR'S WORK SHALL COMPLY WITH THE LATEST EDITION OF THE FOLLOWING CD 7 U NYCENY1 027 -SP1 SITE PLAN & SITE MAP 1 STANDARDS. NYCENY1027 -A01 COMPOUND PLAN, ANTENNA PLAN & GENERAL NOTES 1 AMERICAN CONCRETE INSTITUTE (ACI) 318, BUILDING CODE REQUIREMENTS FOR STRUCTURAL c - 1 4' �� CONCRETE. E NYCENY1027 A02 EQUIPMENT PLAN & NOTES '''94, ORION BUILDINGS NYCENY1027 -A03 MONOPOLE ELEVATION & DETAILS 1 S,Qp \, AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC), MANUAL OF STEEL CONSTRUCTION, NYCENY1027 -A04 REMOTE RADIO HEAD (RRH) MOUNTING DETAILS 1 :1%\c'' ,' THIRTEENTH EDITION. ° NYCENY1027 -E01 SYSTEM DIAGRAM 1 �� `�,� ,� ANSI/TIA (TELECOMMUNICATIONS INDUSTRY ASSOCIATION) 222-F (1996), STRUCTURAL STANDARDS ° . NYCENY1027 -E02 RRH WIRING DIAGRAM 1 °� CO FOR STEEL ANTENNA TOWER AND ANTENNA SUPPORTING STRUCTURES. S c . t. � NYCENY1027 -E03 ELECTRICAL, TVSS NOTES, ASBREV. & SYMBOLS 1 4R- 4 TIA 607, COMMERCIAL BUILDING GROUNDING AND BONDING REQUIREMENTS FOR Z' Z.- NYCENY1027 -E04 GROUNDING NOTES & DETAILS 1 ° TELECOMMUNICATIONS. _c c4-0 N 8g INSTITUTE FOR ELECTRICAL AND ELECTRONICS ENGINEERS (IEEE) 81 , GUIDE FOR MEASURING -°� c p EARTH RESISTIVITY, GROUND IMPEDANCE, AND EARTH SURFACE POTENTIALS OF A GROUND • 7, i' FAQ . SYSTEM SITE m E T_.,. ® IEEE 1100 (1999) RECOMMENDED PRACTICE FOR POWERING AND GROUNDING OF ELECTRONIC o o �p ti 4. �1 EQUIPMENT `J v.- �G° IEEE C2, NATIONAL ELECTRIC SAFETY CODE - LATEST VERSION `) �� 1 l� d' Lm I.W AS dead 4.ssxl °� �j ,-` e r '` , �- TELCORDIA GR-1275, GENERAL INSTALLATION REQUIREMENTS OCl) .�tTs :�/l b/,.,__. R.f'.�, o� c�7�i-- �' G r L. I -: ---� E,' t d. l ��- ANSI T1 .311 , FOR TELECOM - DC POWER SYSTEMS - TELECOM, ENVIRONMENTAL PROTECTION c 2 L ., Y 1 M' '_.. `9u EPARTI•.r L:NT AT r _ o +, FO' �:,','+ TO P R FOR THE �d` y" °' '" FOR ANY CONFLICTS BETWEEN SECTIONS OF LISTED v -c FOLLO 'rIN,1 iNCPL.-.cTIC'NS:. ,w }' i. CODES AND STANDARDS REGARDING °' TWO RI QU dED • C " -° '-.' `-'` ` Yd `' MATERIAL, METHODS OF CONSTRUCTION, OR OTHER REQUIREMENTS, THE MOST RESTRICTIVE rl n l' 1 P A lY 'F� c o ° FC':i POURED CONCRETE REQUIREMENT SHALL GOVERN. WHERE THERE IS CONFLICT BETWEEN A GENERAL REQUIREMENT .c s. l 2. P ;Ur i'I,c;U'_ATION FRAh'lIN� a FLAMING`` - AND A SPECIFIC REQUIREMENT, THE SPECIFIC REQUIREMENT SHALL GOVERN. 6 (6 4. i li'iAI_ - CON S7RUCTION MUST c _c nE COMPLETE r'OR C.O. . .w a) _ ALL CONSTRUCTION SHALL MEET THE n-.*," '' ' r: . --~, 0 -o ->., T ->., REQUIREMENTS OF THE CODES OF NrNEW c YORK STATE. NOT RESPONSIBLE FOR ' v -v DESIGN OR CONSTRUCTION ERRORS. QO 41/ ',= , .,,nDrs PROJECT CONTACTS o ~ a) `,4f... ',L �. N.J . }� Q L � � l' "o -i i, Uw ,'err~ to("„U1j'i1:t� d .. ale'77-7°--7-77:777---" D ETAI L 68 - � 01001 o �..... ...�..... .�.. • -1h' SCALE: N.T.S. NAME COMPANY CONTACT NUMBER `- ' 2,; TYLER CATTELINO BECHTEL (201 ) 571 -0740 o rn CONSTRUCTION STRUCTURAL STATEMENT c -I ...--- 0 .rr ENGINEER ANTHONY LINZO BECHTEL • (201) 571 -0639 o c >, RETAIN STORM WATER RUNOFF o ° +' ;l�, PURSUANT TO CHAPTER 236 RF ENGINEER AZAD KARIM BECHTEL (201 ) 571 -0651 EXISTING TOWER HAS BEEN ANALYSED TO SUPPORT EXISTING AND PROPOSED AT&T EQUIPMENT. L_ OF THE TOWN CODE. NO MODIFICATION TO THE TOWER AND FOUNDATION IS REQUIRED. REFER TO STRUCTURAL REPORT o,3 PREPARED BY PAUL J. FORD & COMPANY DATED MARCH 09, 2015 U O TD l.t icIF NEW •° BECHTEL ASSOCIATES SITE NAME: CUTCHOGUE M/ 0 o o,� m •F 0 tk PROFESSIONAL CORPORATION SITE NUMBER: NYCENY1027 ` = i t m C at8tt , os/12/15 L2C—ISSUED FOR CONSTRUCTION sB cs IM *� �� • ;� E � 0 11/13/14 L2C—ISSUED FOR CONSTRUCTION SB GS AN � � � � � ,�. o - I " TITLE SHEET • L o21855 COUNTY ROAD 48 r , ,dl ic,° o , x ����� � A UNIT OF BECHTEL CORPORATION _6,--s:_,-_'" _t n- ,` CUTCHOGUE, NY 11935N0. DATE REVISIONSBYCHKAPP D ``'2 ;k v5275 WESTVIEW DRIVE s� ,� ,d,�..z _ C p 01* - SCALE: AS NOTED BY: SB DRAWN BY: SB �A " 7807'1 �, SOB NUMBER DRAWING NUMBER REV a a FREDERICK, MD 21703-8386 USA IDESIGNED I °fi NPS o •c L.o BECHTEL DRG. NO.: 25736-415-00-0000-01522 SSS+° 25736-415-LS L2C-NYCENY1027-T01 1 U 3 0 O L- •` O EXISTING MONOPOLE ZONING TABLE: CUTCHOGUE "LI" � a s c TAX LOT #17.5 N/0/F TOWN OF SOUTHOLD EXISTING STORAGE CONTAINER LIGHT INDUSTRIAL ZONING DISTRICT v ° m v --EXISTING VERIZON SHELTER ITEM: REQUIRED EXISTING PROPOSED -'-' (0). EXISTING CSC CABINET -2.2'NW D L APPROXIMATE LOCATION OF 10.9 SWMAX. HEIGHT (FT) 80 108'-6"± NC 17.7'SE MIN. LOT AREA (SF) 40,000 45,589±.... NC 3 v VERIZON EASEMENT4.0'NW •• • ' L_ (RECORD-EXIBIT "A" V105786) HA'N LINK FENCE 188. :' • - _• MIN. LOT WIDTH (FT) 100 168.17±.... NC o ,00» E C • • _ •• - -- 7 110.4' MIN. LOT DEPTH (FT) 150 263.16±.. NC °-4, N 23.14'00" ! - - -- - ~ MINIMUM FRONT YARD SETBACK (FT) 100 *75± NC t I v • — - _�r x--x- EXISTING (1) .c °' • • - — �- T -_x__---x---x---x STY MINIMUM SIDE YARD SETBACK-ONE (FT) 20 *15.2± NC " m — x IL511) MINIMUM SIDE YARD SETBACK-BOTH FT .... 40 45.1 ± NC 0 c EXISTING T-MOBLE - x METAL& FRAME O � a I GRASS EQUIPMENT PAD x �� MINIMUM REAR YARD SETBACK FT 70 *11 .1 ± NC EXISTING ICE BRIDGE 30 45.62E NC __ MAX LOT COVERAGE (%) �� / - _ - _ J...IrieC2141 � EXISTING GPS UNIT TO REMAIN c c� / iitIJiill r --- - NA = NOT APPLICABLE = v FI -_ \ I EXISTING METROPCS I - EXISTING STORAGE CONTAINER NCNO CHANGE I * EXISTING DIMENSIONAL NON-CONFORMITY �.. 0 co00 0 I i ■ Vli " Z I GRASS ■ v N O ,,, 0 -EXISTING NEXTEL SHELTER E , N p- EXISTING GENERATOR o p U ^ x� I >,N � I- I 9.3'SW � o Wo I .c w Y I --EXISTING AT&T C 0 Q I I I EQUIPMENT PAD ( E D I ( RIGHT OF WAY EASEMENT 2 aa) I AREA (COMMON DRIVEWAY L_ a 45.589 SQFT. I w 1.0456 ACRES `O O z I 1 1 c D I I EDGE OF ASPHALT o i a) nI \ EXISTING 13.1' SW I EXISTING ASPHALT PARKING PARKING �i 13a I I N w Q ` , L_-_38.3'T15 `) AX LOT #19.1 14.85'W -\,\ I - --� D O , v I 13.55 SW Q ( ROOF OVER \ \ i O 1E x k 4, c9.9' _I 1 1 ��\ EXISTING (1) c -0I- 7 I CONCRETE STY •� c I }' ` 22.7 FRAME I • , EXISTING I w m �- -- Lv -c• c I I (1) STY METAL > > Q 5 I I (AUTO SHOP) I o v J I U o o I I o �� U7 O U N — ^ O c :n I CONCRETE PAVEMENT < - 38.0' I J w U • 0 U p ' 1' -— - J CD J Y I I-'- ROOF OVER < o Z wX ' 1 1 I ..;\11- 0- w pQ zI w o- v zm I F- Ln LOT 20.1 I . 0 v CLI m m N/0/F CHRISTOPHER MOHR o 0 I ' GRASS o EXISTING J v °' w o ASPHALT > I E •� oP o v z I I ICO PARKING I .- \ii I 0 T73. � -�-- v I v) c 703.32'(ACTUAL) v :� WOOD CURB o I I R=71.52' c LILCO ? I GRASS ±750 (DEED) L=122.85' o o UTILITY POLE \ • v 0 #420 / I ✓ c N I I ±20.00 c a CONCRETE CURB U _ _� \ o .�' CURB -UTILITY POLE N v - — — CONCRETE #421 • t Q 1ELEC. CONDUIT 68.17 (MARK—OUT) S 255230 W MIDDLE (120' WIDE) ROAD oN Cn•c _ - FULL SCALE 1 "=20'-0" o a (C. R. 48) 0 v (NORTH ROAD) NOTE. TO THE BEST OF OUR KNOWLEDGE, THE 20 10 0 20 40 FT ° :n NOTE: SITE PLAN BASED ON SURVEY BY AREK SITE PLAN 1 PROPOSED EQUIPMENT MODIFICATIONS BY AT&T ,„ e„ . „ a F' SURVEYING COMPANY DATED 06/04/2009 AND WILL HAVE LITTLE IMPACT ON THE EXISTING 34-81-- A SITE VISIT BY BECHTEL ON 06/10/2012 SCALE: 20'=1 '-0” SP1 NOISE LEVELS AT THE EXISTING FACILITY. HALF SCALE 1 "=40'-0" z c a SITE NAME: CUTCHOGUE (CCIFco0.440 yo--- 3 at&t BECHTEL ASSOCIATES �0 �o �, �,� O � , 4 1 06/12/15 L2C-ISSUED FOR CONSTRUCTION SB GS IM R 7� 0° •F 0 „-' PROFESSIONAL CORPORATION SITE NUMBER: NYCENY1027 o „/13/14 L2C-ISSUED FOR CONSTRUCTION s6 GS AN a �' c � A UNIT OF BECHTEL CORPORATION 21855 COUNTY ROAD 48 L $( / / - 1 .i ` c SITE PLAN & SITE MAP NO. DATE REVISIONS BY CHK APP'D R'' 0,1Y 5. ` 4 z 2 �F - a . c v 5275 WESTVIEW DRIVE CUTCHOGUE, NY 11935 \. '� c p fr I , SCALE: AS NOTED DESIGNED BY: SB DRAWN BY: SB c`" 9 ' l'''cl ' . —JOB DRAWING NUMBER REV I= a; 0 FREDERICK, MD 21703-8386 USA 4, 784 P� o L o BECHTEL DRG. NO.: 25736-415-CO-0000-01522 °'�ESSjO\' 25736-415-LS L2C-NYCENY1027-SP1 1 U 3 U L. .2 °' LOT 17.3 EXISTING CSC GENERAL NOTES �' TOWN OF SOUTHOLD CABINET ` , _ EXISTING STORAGE CONTAINER ., i/1/ 21565 COUNTY ROAD 48 _ _ ! 1 . FOR THE PURPOSE OF CONSTRUCTION DRAWING, THE FOLLOWING DEFINITIONS SHALL s ° - -I EXISTING MONOPOLE APPLY: a' a� _ -� riati =-- I CONTRACTOR - BECHTEL m7 EXISTING T-MOBLEEXISTING VERIZON SHELTER SUBCONTRACTOR - GENERAL CONTRACTOR CONSTRUCTION 0 EQUIPMENT PAD ( „D E �. __ i-_ OWNER - NEW CINGULAR WIRELESS PCS, LLC ("AT&T") 3 2 t'✓) EXISTING METFop-R---, EXISTING ICE BRIDGE OEM - ORIGINAL EQUIPMENT MANUFACTURER EQUIPMENT COMPOUND 'EXISTING STORAGE CONTAINER I .1111 — I 2. PRIOR TO THE SUBMISSION OF BIDS, THE BIDDING SUBCONTRACTOR SHALL VISIT THE CELL a D I SITE TO FAMILIARIZE WITH THE EXISTING CONDITIONS AND TO CONFIRM THAT THE WORK CAN .+-' BE ACCOMPLISHED AS SHOWN ON THE CONSTRUCTION DRAWINGS. ANY DISCREPANCY -6 0 i \ 0 / . . .� m ; EXISTING GENERATOR FOUND SHALL BE BROUGHT TO THE ATTENTION OF CONTRACTOR. 0 ° I EXISTING AT&T 1 EXISTING GPS UNIT TO REMAIN 3. ALL MATERIALS FURNISHED AND INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL I a I EQUIPMENT PAD 0 I APPLICABLE CODES, REGULATIONS, AND ORDINANCES. SUBCONTRACTOR SHALL ISSUE ALL c 0 A03 EXISTING NEXTEL SHELTER APPROPRIATE NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS, AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY REGARDING THE PERFORMANCE OF THE WORK. \ 0 c U >,C 0 \ --EXISTING EXISTING LTE GPS UNIT TO REMAIN 4. ALL WORK CARRIED OUT SHALL COMPLY WITH ALL APPLICABLE MUNICIPAL AND UTILITY .° 0 1 PARKING COMPANY SPECIFICATIONS AND LOCAL JURISDICTIONAL CODES, ORDINANCES AND APPLICABLE o I REGULATIONS. o II 5. UNLESS NOTED OTHERWISE, THE WORK SHALL INCLUDE FURNISHING MATERIALS, EQUIPMENT, �o O w APPURTENANCES, AND LABOR NECESSARY TO COMPLETE ALL INSTALLATIONS AS INDICATED ON C EXISTING Q THE DRAWINGS. ° (1) STY METAL J 'c -►., (AUTO SHOP) I EXISTING (1) STY 6. THE SUBCONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH 0 a , ', i i FRAME ox MANUFACTURER'S RECOMMENDATIONS UNLESS SPECIFICALLY STATED OTHERWISE. S E \ U LOT 18.3 i 7. IF THE SPECIFIED EQUIPMENT CANNOT BE INSTALLED AS SHOWN ON THESE DRAWINGS, THE °a. o, JENNIE HARRIS 0 EXISTING PROPERTY SUBCONTRACTOR SHALL PROPOSE AN ALTERNATIVE INSTALLATION FOR APPROVAL BY THE Q COUNTY ROAD 48 1 LINE (TYP.) CONTRACTOR. o EXISTING ° I 0 • PARKING �� I LOT 20.1 8. SUBCONTRACTOR SHALL DETERMINE ACTUAL ROUTING OF CONDUIT, POWER AND Ti CABLES, 0 D \ I CHRISTOPHER MOHR GROUNDING CABLES AS SHOWN ON THE POWER, GROUNDING AND TELCO PLAN DRAWING. o 22155 COUNTY ROAD 48 SUBCONTRACTOR SHALL UTILIZE EXISTING TRAYS AND/OR SHALL ADD NEW TRAYS AS Ti a 0 NECESSARY. SUBCONTRACTOR SHALL CONFIRM THE ACTUAL ROUTING WITH THE CONTRACTOR. E) 1 OO —_ _ ROUTING OF TRENCHING SHALL BE APPROVED BY CONTRACTOR. 0 _ _ - ,-- FULL SCALE 1 /32"=1 '-0" 9. THE SUBCONTRACTOR SHALL PROTECT EXISTING IMPROVEMENTS, PAVEMENTS, CURBS, �— LANDSCAPING AND STRUCTURES. ANY DAMAGED PART SHALL BE REPAIRED AT a) -°° - 32 16 0 32 64 FT SUBCONTRACTOR'S EXPENSE TO THE SATISFACTION OF OWNER. o 01 OUNTY ROAD 4 COMPOUND PLAN 1 I.,m______ +' '''' A01 HALF SCALE 1/64"=1 '-0" 10. SUBCONTRACTOR SHALL LEGALLY AND PROPERLY DISPOSE OF ALL SCRAP MATERIALS SUCH o SCALE: 1 /32"=1 '-0" AS COAXIAL CABLES AND OTHER ITEMS REMOVED FROM THE EXISTING FACILITY. ANTENNAS REMOVED SHALL BE RETURNED TO THE OWNER'S DESIGNATED LOCATION. - c EXISTING AT&T ANTENNA TO REMAIN o a N EXISTING AT&T ANTENNA TO REMAIN (SECTOR A) 11 . SUBCONTRACTOR SHALL LEAVE PREMISES IN CLEAN CONDITION. A 0 (SECTOR A) a SWAP EXISTING 1 LTE ANDREW ANTENNA WITH 1 12. ALL CONCRETE REPAIR WORK SHALL BE DONE IN ACCORDANCE WITH AMERICAN CONCRETE s o TD A \ PROPOSED LTE ANDREW AT&T SBNHH-1 D65A HEXPORT INSTITUTE (ACI) 301 . 0 o EXISTING (1) 700 MHz RRH ON o 0 CD ANTENNA ON EXISTING PIPE MAST (SECTOR m E EXISTING PIPE (SEE DETAIL 1/A04) '� 1- A) 13. ANY NEW CONCRETE NEEDED FOR THE CONSTRUCTION SHALL HAVE 4000 PSI STRENGTH AT 0 0 �, (SECTOR A) w (SEE DETAIL 2&3/A03) 28 DAYS UNLESS OTHERWISE SPECIFIED. ALL CONCRETING WORK SHALL BE DONE IN c �/ cn / ACCORDANCE WITH ACI 318 CODE REQUIREMENTS. o- `'� EXISTING MONOPOLE INSTALL (1) 1900 MHz RRH ON EXISTING PIPE INSTALL (1) 1900 MHz RRH ON (SEE DETAIL 1/A04) (SECTOR A) 14. ALL STRUCTURAL STEEL WORK SHALL BE DONE IN ACCORDANCE WITH RISC SPECIFICATIONS. L.a_ a) a EXISTING PIPE (SEE DETAIL 1/A04) i ' EXISTING RAYCAP DC6 DOME ON 15. CONSTRUCTION SHALL COMPLY WITH SPECIFICATION 25736-000-3PS-AOOZ-00001 , 0 0 (SECTOR C) .11 i. EXISTING PIPE MAST ON T-ARM GENERAL CONSTRUCTION SERVICES. v o, SWAP EXISTING (1) LTE ANDREW �I EXISTING (1 ) 700 MHz RRH ON EXISTING PIPE 16. SUBCONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS AND CONDITIONS PRIOR TO . ANTENNA WITH (1) PROPOSED LTE (SEE DETAIL 1/A04) (SECTOR B) COMMENCING ANY WORK. ALL DIMENSIONS OF EXISTING CONSTRUCTION SHOWN ON THE ° °' ANDREW AT&T SBNHH-1D65A t• • DRAWINGS MUST BE VERIFIED. SUBCONTRACTOR SHALL NOTIFY THE CONTRACTOR OF ANY .c ..c ( ) �! DISCREPANCIES PRIOR TO ORDERING MATERIAL OR PROCEEDING WITH CONSTRUCTION. _ HEXPORT ANTENNA ON EXISTING telgilr• EXISTING AT&T ANTENNA TO ° v PIPE MAST (SECTOR C) ,,�� REMAIN (SECTOR B) 17. THE EXISTING CELL SITE IS IN FULL COMMERCIAL OPERATION. ANY CONSTRUCTION WORK (SEE DETAIL 2&3/A03) %• ‘ #"*�`' � • '� 4 BY SUBCONTRACTOR SHALL NOT DISRUPT THE EXISTING NORMAL OPERATION. ANY WORK ON v \ EXISTING AT&T ANTENNA TO '' EXISTING EQUIPMENT MUST BE COORDINATED WITH CONTRACTOR. ALSO, WORK MAY BE v o • EXISTING AT&T ANTENNA TO = ''G / / REMAIN (SECTOR B) SCHEDULED FOR AN APPROPRIATE MAINTENANCE WINDOW USUALLY IN LOW TRAFFIC PERIODS 0 W REMAIN (SECTOR C) cG��NO SFc AFTER MIDNIGHT. F_ Z S 9, T� 12�'Q •e,, 18. SINCE THE CELL SITE MAY BE ACTIVE, ALL SAFETY PRECAUTIONS MUST BE TAKEN WHEN 0 a EXISTING AT&T ANTENNA TO WORKING AROUND HIGH LEVELS OF ELECTROMAGNETIC RADIATION. EQUIPMENT SHOULD BE 0 �' REMAIN (SECTOR C) \\ SHUTDOWN PRIOR TO PERFORMING ANY WORK THAT COULD EXPOSE THE WORKERS TO ii > - NOTE : DANGER. PERSONAL RF EXPOSURE MONITORS ARE REQUIRED TO BE WORN TO ALERT OF ANY .°' LTE ANTENNA AZIMUTHS SHOWN ARE PRELIMINARY EXISTING (1 ) 700 MHz RRH ON SWAP EXISTING (1) LTE ANDREW ANTENNA WITH (1) DANGEROUS EXPOSURE LEVELS. / 1D65A HEXPORT ci ° = AND MAY NOT REFLECT FINAL RF DESIGN. REFER EXISTING PIPE (SEE DETAIL 1/A04) PROPOSED LTE ANDREW AT&T (SBNHH ) a TO LATEST RF DATA SHEET FOR FINAL LTE ANTENNA ON EXISTING PIPE MAST (SECTOR B) / o • ANTENNA SPECIFICATIONS, AZIMUTHS, TILTS, ETC. (SECTOR C) (SEE DETAIL 2&3/A03) "' c'J INSTALL (1) 1900 MHz RRH ON FULL SCALE 3/16"=1 '-0" o => , NOTES: EXISTING PIPE (SEE DETAIL 1/A04) 4 0 4 8 12 Fr DETAIL v 1006 o -1-' 0 1 . ANTENNA ORIENTATION/AZIMUTHS SHALL BE FIELD VERIFIED. (SECTOR B) a 2. EQUIPMENT/ANTENNAS BY OTHERS NOT SHOWN FOR CLARITY. ANTENNA PLAN 2 —=-- Ao1 SCALE: N.T.S. L_ SCALE: 3/16"= 1 '—0" A01 HALF SCALE 3/32"=1 '-0" I--- z - 5 J of NE3a o - SITE NAME: CUTCHOGUE �P�aU o. MoGYo,� 3 at&t m •� BECHTEL ASSOCIATES 7 1 06/12/15 L2C—ISSUED FOR CONSTRUCTION SB GS IM *��� \:mr-f T9'� 4. ' eli PROFESSIONAL CORPORATION SITE NUMBER: NYCENY102 � , COMPOUND PLAN, ANTENNA PLAN & • ° IIiII1 " 0 11/13/14 L2C—ISSUED FOR CONSTRUCTION SB GS AN r-- : ' cc 21855 COUNTY ROAD 48 0 o - x. A UNIT OF BECHTEL CORPORATION8m _ �''�, w' GENERAL NOTES s °-+4 oft CUTCHOGUE, NY 11935 NO. DATE REVISIONS BY CHK APP D �� ^��; 1 ? , _ °, v Of 5275 WESTVIEW DRIVE •L c _ r SCALE: AS NOTED DESIGNED BY: SB DRAWN BY: SB ' -6. - 9180fi 1 <<-; JOB NUMBER DRAWING NUMBER REV >,.a? a FREDERICK, MD 21703-8386 USA '°90P NPS CI o BECHTEL DRG. NO.: 25736-415-00-0000-01522 �ss�° 25736-415-LS L2C-NYCENY1027-A01 1 O co CONSTRUCTION NOTES �ri) NOTES: v ° 1 . FIELD VERIFICATION: m ' SUBCONTRACTOR SHALL FIELD VERIFY SCOPE OF WORK, AT&T ANTENNA PLATFORM LOCATION = U AND ANTENNAS TO BE REPLACED. O = 3 0 2. COORDINATION OF WORK: SUBCONTRACTOR SHALL COORDINATE RF WORK AND PROCEDURES WITH CONTRACTOR. o - 3. CABLE LADDER RACK: a )� SUBCONTRACTOR SHALL FURNISH AND INSTALL CABLE LADDER RACK, CABLE TRAY, AND - a) CONDUIT AS REQUIRED TO SUPPORT CABLES TO THE NEW BTS LOCATION. U CO N c m <y o 1007 DETAIL c � irj �- A02 SCALE: N.T.S. o� 10,_0„ + + - x :+ + v ci Ox �- - - +� r F BIERINMANAGE ENT BOX STRUCTURAL STEEL NOTES E EXISTING METER I r — EXISTING + + o M — x ARGUS o \ TE20B + + NOTES: �" I \ D x BATTERY y + v z° I r \ CABINET + 1 . ALL STEEL WORK SHALL BE PAINTED OR GALVANIZED IN ACCORDANCE WITH THE c EXISTING DISC. \ x r L - - + i BUSINESS LINE SPECIFICATIONS. AT&T LOCAL MARKET REPRESENTATIVE SHALL I PROVIDE DIRECTION IF PAINTING OR GALVANIZING OF STRUCTURAL STEEL IS x �\ EXISTING + + o EXISTING GPS PREFERRED. o �' ARCUS TE21 + UNIT TO REMAIN Q I �� POWER H + + 2. ALL WELDING SHALL BE PERFORMED USING E70XX ELECTRODES AND WELDING SHALL o EXISTING — x , — CABINET + ' CONFORM TO AISC. WHERE FILLET WELD SIZES ARE NOT SHOWN, PROVIDE THE o — AC PANEL I _ + + MINIMUM SIZE PER TABLE J2.4 IN THE AISC "MANUAL OF STEEL CONSTRUCTION". c \ x — EXISTING + i PAINTED SURFACES SHALL BE TOUCHED UP. {- + o = Z x _1 // a NOKIA + + + 3. BOLTED CONNECTIONS SHALL BE ASTM A325 BEARING TYPE (3/4"0) CONNECTIONS �, o- I a a / OUTDOOR + AND SHALL HAVE MINIMUM OF TWO BOLTS UNLESS NOTED OTHERWISE. 'v -� CABINET + + E r I — + {_ , ‘ 4. NON-STRUCTURAL CONNECTIONS FOR STEEL GRATING MAY USE 5/8" DIA. ASTM A Ou x i' EXISTING + 307 BOLTS UNLESS NOTED OTHERWISE. EXISTING TELCO O 'J n + + + - EXISTING NEXTEL BOX ( _ NOKIA + SHELTER 5. POST INSTALLED ANCHORS SHALL BE PROVIDED IN ACCORDANCE WITH SPECIFICATION ca x oo OUTDOOR o CABINET �- + + 3GS-T18-00013 "SELECTION, DESIGN, INSTALLATION, INSPECTION AND TESTING OF v I — — — ' ADHESIVE AND MECHANICAL EXPANSION ANCHORS FOR WIRELESS SITE FACILITIES". O •- EXISTING x - ANCHORS SHALL BE HILTI OR APPROVED EQUAL, INSTALLED, INSPECTED AND TESTED c ' - METROPCS I 4 4 �I �� _ - + + i EXISTING PURCELL AS SHOWN ON THE DESIGN DRAWINGS. NO REINFORCING STEEL SHALL BE CUT 0 1 1 i t EQUIPMENT x / + STACKED CABINETS WITHOUT PRIOR ENGINEERING APPROVAL. v COMPOUND I 1 + 4 --C x ' } + INSTALL (1) 1900 bCEM IN 6. UNLESS NOTED OTHERWISE, BAR GRATING SHALL BE 1 1/2" x 3/16". GRATING <4 LiEXISTING ALU BBU LOCATED IN SHALL BE GALVANIZED THROUGHOUT AND BANDED ON ALL EDGES, WHERE EXPOSED. TD 0 I - EXISTING PURCELL CABINET GRATING FASTENERS SHALL BE SADDLE CLIP SYSTEM AS MANUFACTURED BY HILTI OR °' ° Z x �— + ENGINEERING APPROVED EQUAL. FASTENER SPACING SHALL COMPLY WITH m I n + + + MANUFACTURERS RECOMMENDATIONS, BUT SHALL NOT BE LESS THAN FOUR c I I x 1\ EXISTING + + + FASTENERS PER PANEL. LN• I 4 d ° �, x a \ LUCENT ;4 + i 5..0 EXISTING GPS UNIT _ I a ci TO REMAIN DETAIL o x 01 c o 0x � A02 SCALE: N.T.S. O (° n v Lx t.. O I 4 v g3 1 c , EXISTING 7—x x x—s.x x x x x x x-2. • �� DOOR �* EXISTING o o • �+ FENCE LINE o•c F_ L -° � uoi ✓ a ° O 2 L- C) U cn N t.[) > • O -oC_ N ° IN Q t 1oN .cam FULL SCALE 1/2"=1 '-0" c v I TOTAL REQUIRED RECTIFIERS UNDER EQUIPMENT PAD PLAN 1 12" 0 1 2 3 4 5 FT Ls s g THIS 2C SCOPE IS (6). TOTAL REQUIRED v o CONVERTERS UNDER THIS 2C SCOPE IS (3). SCALE: 1 /2"=1 '-0" A02 / HALF SCALE 1 4"=1 '-0" z , TS aF NEw 3 BECHTEL ASSOCIATES SITE NAME: CUTCHOGUE _ ,,,,,is o,, o. M°„�o�, at&t 0° •� PROFESSIONAL CORPORATION SITE NUMBER: NYCENY1027 1 os/12/15 L2C–ISSUED FOR CONSTRUCTION se GS IM *�z- �-' '...� © E 21855 COUNTY ROAD 48 ” ""'� 0 11/13/14 L2C-ISSUED FOR CONSTRUCTION SB GS AN r "i ✓ l- , o cc - , A UNIT OF BECHTEL CORPORATION - a - ,:,,i ,�_.. V? LU EQUIPMENT PLAN & NOTES °- ' CUTCHOGUE, NY 1 1935Li_ °, o ►' 5275 WESTVIEW DRIVE N0. DATE REVISIONS BY CHK APP�D 5"2 ;�t •C 0 FREDERICK, MD 21703-8386 USA SCALE: AS NOTED DESIGNED BY: SB DRAWN BY: SB ovi/v°91:11,: :'74,J JOB NUMBER DRAWING NUMBER REV o 3 BECHTEL DRG. NO.: 25736-415-CO-0000-01522 ROFESS\OP 25736-415-LS L2C-NYCENY1027- A02 1 I,-L _2 , 1 A.1I I L L. O " •- a) ao 0 °- MECHANICAL °3 V DOWN-TILT ASSY. o o m -\ RAD. CENTER OF EXISTING METROPCS ANTENNAS .� \� .a. j. 111 '-6" f A.G.L. o D -C ANTENNA �\ ° MOUNTING HARDWARE _° f _\ a TOP OF EXISTING TOWER . , >c (FIT AS REQUIRED) 108'-6" ± A.G.L. . o a a) ,-, a) 0 m RAD CENTER OF EXISTING VERIZON ANTENNAS m a 100'-0" ± A.G.L. a) ANTENNA C O N C c U of .... [...1) RAD. CENTER OF EXISTING T-MOBILE ANTENNAS o ANTENNA MOUNTING PIPE c 90 -0" f A.G.L. 4 6 v N o L° -- -- - o \I\�� EXISTING RAYCAP DC6 DOME ON >,N ,� EXISTING PIPE MAST ON T-ARM RAD. CENTER OF EXISTING NEXTEL ANTENNAS C M JI f c o — -40- o t'� I 1 80'-0" ± A.G.L. cZ a ." v 'O"' T �' a a( R INSTALL (1) 1900 MHz RRH ON S w '',1- \r- /7 EXISTING PIPE (SEE DETAIL 1/A04) RAD. CENTER OF EXISTING & PROPOSED AT&T ANTENNAS 0 0 0 L_ Q JUMPER (S) TO //// (TYP. ALL SECTORS) 70'-0" f A.G.L. (TYP. ALL SECTORS) a� REMOTE RADIO _- _ - --4P-` ° HEADS (RRHs) - `- // .0—] 41% a . ., �' o } C •.� / EXISTING 700 MHz RRH ON in in EXISTING PIPE (SEE DETAIL 1/A04) T, E. 2 ANTENNA MOUNTING DETAIL (TYP. ALL SECTORS) EXISTING (2) AT&T ANTENNA TO REMAIN A03 SCALE: N.T.S.� (TYP. ALL SECTORS) -SWAP EXISTING (1) LTE ANDREW ANTENNA WITH (1) -v� E PROPOSED LTE ANDREW AT&T (SBNHH-1D65A) HEXPORT a o ANTENNA ON EXISTING PIPE MAST (TYP. ALL SECTORS) 11 .85"� 7.1 (SEE DETAIL 2&3/A03) o ""-IE 1 j o �� o • EXISTING MONOPOLE iim -D -. o 4 tc C t o m ° 0 o in in in EXISTING NEXTEL EQUIPMENT SHELTER c FRONT ° ° EXISTING GPS UNIT TO REMAIN a) 0 .` o n a S EXISTING LTE GPS UNIT TO REMAIN - C 0 ° EXISTING AT&T ICE BRIDGE - \ EXISTING VERIZON E °' = ' L' EQUIPMENT SHELTER EXISTING EQUIPMENT CABINETS \ I.E 0 \ EXISTING CHAINLINK - a, � EXISTING CHAINLINK FENCE - \ \ \,\ FENCE FRONT ELEVATION SIDE VIEW \ \ r _ Y a) \ • n\1 n MECHANICAL CHARACTERISTICS ` ,C 'v WEIGHT: 40.92LBS (18.56KG) y' \. ; ; �:,',{ .4 . .. \ \. :u. . . ' TOP SOF GRADE o a WIND LOAD (C�150MPH): 100LBF (445.ON) 0 -0 AGL U . U, MAX. WIND SPEED: 150MPH (241 .4KM/HR) in > o _a 'L N v NOTE: ANTENNA CONFIGURATION .c .--ti AND AZIMUTHS TO BE FIELD VERIFIED. -w '' • LTE ANDREW ANTENNA .0 _1 3 SBNHH-1D65A N a MONOPOLE ELEVATION 1 FULL SCALE 1 /8"=1 '-0" o A03 SCALE: N.T.S. �, A03 8 �, � ® � 8 16 FT ° -c ° SCALE: 1 ,/8 =1 -0 , E-3 HALF SCALE 1 /16 =1 -0 o TD', • < �pfNEtNY o ' SITE NAME: CUTCHOGUE ,�Q� °� 0. MOG op 3 at&t •- BECHTEL ASSOCIATES NY1 27 �—�, 1 06/12/15 L2C-ISSUED FOR CONSTRUCTION SB GS IM *� �`� , ��'� co • "I PROFESSIONAL CORPORATION SITE NUMBER: NYCE O Il .. 0 11/13/14 L2C-ISSUED FOR CONSTRUCTION SB GS AN Q;��� � ' W o �- c 21855 COUNTY ROAD 48 j_,,`r :�_ MONOPOLE ELEVATION & DETAILS Of" . A UNIT OF BECHTEL CORPORATION m+, a� O N0. DATE REVISIONS BY CHK App'D 2:� ,< eL v •.` 5275 WESTVIEW DRIVE CUTCHOGUE, NY 1 1935 ``.6- ` ,:c., _ SCALE: AS NOTED DESIGNED BY: SB DRAWN BY: SB ,o , 9 80`7 ��, JOB NUMBER DRAWING NUMBER REV �; O I- •- a) C" O .5 WIDTH WIDTH _c c v ami I..LI 1 ■ II Ill II MI :1 �y,1 3'14F1�1': +"Y'srti = ` I 4-* f� IU 0 D [ 33 4 I C '4-�vt 11 t EXISTINGv 700 MHz i- _ °-_c RRHc� c')" ` EXISTING " • w wr m MANUFACTURER 0 700 MHz , =0 SUPPLIED PIPE RRH aI ° MOUNTS \ c - i++ .``I o � - ll ' I c � L o c U 01 -___A • 700 / 700 AT / 700 B29 1900 4R / WCS o P 850 / 1900 o 0° PROPOSED 1900 MHz RRH - -� 4 `O m o M (SEE [DETAIL 1104-NYC-L2C) 5 rt , 1 I)"- o N L...;-..R= SIZE AND WEIGHT TABLE ,c Z 4 ` °� HEIGHT W/O CABLE WEIGHT C � PROPOSED 1900 MHz RRH RRH WIDTH DEPTH MANAGEMENT COVER W/O BRACKET v EXISTING PIPE -►- (SEE DETAIL 1104-NYC-L2C) TOP VIEW RRH 700 MHz �, 12.2" 10.8" 20.9" 50.7 LBS. n. o, MAST 2X40 (80W) L Q RRH 700 MHz (B17) 2X40 (80W) (RETUNED) 12.2" 6.1 " 25.2" 52.5 LBS. o ELEVATION WITH SOLAR SHIELD ° U) RRH 700 MHz (B29) T, a Q 2X40 (80W) 12.2" 6.6" 25.2" 55 LBS. WITH SOLAR SHIELD 7 ?? RRH 850 MHz 11 .5" 9.0" 18.9" 50 LBS. ° 2X60 D 0 EXISTING PIPE MAST o a) RRH 1900 MHz „ „ v, 2X60 (120W) 11.2 7.2 20.1 43 LBS. -, O 0 EXISTING CONNECTION RRH 1900 4R MHz " c -0 � i� �� 2X60 11 .2" 7.6" 20.1 46.2 LBS. cll' .j •� c / - EXISTING SQUARE TUBE 'v0 4-1 STANDOFF RRH (WCS B30) �, 4X25 11 .8" 7.9" 29.5" 70 LBS. \ CONNECTORS. .� o � 4; C ,.2I NOTE: DIMENSIONS INCLUDE MOUNTING BRACKET, SOLAR SHIELD AND o ,� ALL CONNECTIONS SHALL BE ACCORDING TO ALU INSTALLATION MANUAL. co ° 1 C) 0 0 � 4 c . •'')• . „-‘ v \ / ..c •- vMINIMUM CLEARANCE TABLE o° 'i CLEARANCES (INCHES) L. o RRH CABINET 700/700B17/700629 850/1900/19004R 2300 WCS COMMENTS orn rFRONT 36" 39.4" 39.4" INSTALLATION ACCESS L 0 •� REAR 2" 2.8" 2" 0" REAR CLEARANCE IF SUPPLIED c MOUNTING BRACKETS IS USED 75 vz- 2 RIGHT 4" 3.9" 3.9" AIR FLOW c LEFT 4" 3.9" 3.9" AIR FLOW c = '.1 " m -0 ISOMETRIC TOP 12" 11 .8" 11 .8" AIR FLOW •o __a) BOTTOM 12" 12" 12" CONDUIT ROUTING o Q L- 0 Cl)_ 6 g t Q RRH MOUNTING DETAIL (TYP ALL SECTORS) 1 ALCATEL-LUCENT 9442 REMOTE RADIO HEAD (RRH) 1 104-NYC-L2C N Co_j SCALE: NTS A04 A04 J SCALE: N.T.S. c :6 o c >, v 03jo 0 -c o 3 .1) Z c'.3 � �� NES,0 at8ct .c o ¢ SITE NAME: CUTCHOGUE ��P� `' "'° �� U •- -° BECHTEL ASSOCIATES 1 06�12�15 L2C-ISSUED FOR CONSTRUCTION SB GS IM s�- Z'r m 0 PROFESSIONAL CORPORATION SITE NUMBER: NYCENY1027LL 0 11/13/14 L2C-ISSUED FOR CONSTRUCTION s6 GS AN , � W REMOTE RADIO HEAD (RRH) MOUNTING DETAILS o � c � � 21855 COUNTY ROAD 48 � ei m r� -' u a o Of = A UNIT OF BECHTEL CORPORATION CUTCHOGUE NY 1 1935 s ,, ,� � �� � N0. DATE REVISIONS BY CHK APP D 2. �� <r �;,�;,,,�� � � ? _ �-- v ! � 5275 WESTVIEW DRIVE SCALE: AS NOTED DESIGNED BY: SB DRAWN BY: SB R,0 9/807-'/ ,.,t.,',/ JOB NUMBER DRAWING NUMBER REV I I °FE s�oNQ� -NYCENY1027- AO4 1 a o s 25736-415-LS L2C •�� tFREDERICK, MD 21703-8386 USA o °- BECHTEL DRG. NO.: 25736-415-CO-0000-01522 o '� o 0 3 0 -,ISL 4 /-1) I L) L- •O- a) a O (,) 0- -° a) TOWARD TOWARD ANTENNAS SEE RF DATA SHEET NOTES: m 2 O " A A A A A A A A A A 2. INSTALLED BY OEM OEM/AT&T.1 . FURNISHED BY RAS SCOPED BY MARKET. •cA A A � AA v AISG CABLE FOR 3.4. NSTALLEDD BYY BECHTEL. ,L_ RET CONTROL NOTES: 3, 4, 21 5. FINAL CONNECTION BY OEM OR AS SCOPED BY MARKET. 0 - (TYP FOR 3) 6. OPEN END OF CONDUIT TO BE LEFT WEATHERPROOFED UNTIL TERMINATED. _ - 7. ARGUS 053-997-20-0000 DUAL FEED DC-DC CONVERTER WITH -C `\ 012-526-20-040 2KW MODULES. 0 00 COAX JUMPERS RRH-A1 RRH-A2 RRH-B1 RRH-B2 RRH-C1 RRH-C2 8, PART OF CONVERTER WITH 18 BREAKER POSITIONS. BREAKERS SPECIFIED m c NOTES: 3, 4, 13 700 BAND 1900 OR 700 BAND 1900 OR 700 BAND 1900 OR SEPARATELY. AWS BAND AWS BAND AWS BAND 9. BREAKERS TO BE TAGGED AND LOCKED OUT. c 3 NOTES: NOTES: NOTES: NOTES: NOTES: NOTES: O a -I 1 , 2, 5 1 , 2, 5 1 , 2, 5 1 , 2, 5 1 , 2, 5 1 , 2, 5 10. SIAD IS FURNISHED AND INSTALLED BY OTHERS AND INCLUDES POWER CONNECTIONS AND FIBER TO THE UNIT OR AS SCOPED BY MARKET. WHEN c(..) RRH-A2 r I �- 1 I I I I IN BECHTEL SCOPE, INSTALL 10 AWG CHASSIS GROUND, PROVIDE (2) 10A >,0 700BAND1900 OR _ F MODE ' I ' ' ' _' 2 AWG BREAKERS FROM A 24V DC POWER SOURCE OR (2) 5A BREAKERS FROM I -° o NOTES: A NOTES: D 1 PAIR, SINGL_ _ _ _ _ __ _ _ (TYP FOR 6) A 48V DC POWER SOURCE AND CONNECT USING MFR POWER CABLE WITH FIBER CABLESPECIAL E 1 , 2, 5 1 , 2, 5 NOTES: 3, 4, 5, 13 -DI - -_--. co - - - NOTE: 13 11 . DELETED CONNECTOR. o -•,�, (TYP FOR 6) C -i coaa m 12. LEC TO FURNISH AND INSTALL NETWORK INTERFACE DEVICE. `'- o ; ; =s 13. LEAVE COILED AND PROTECTED UNTIL TERMINATED. ,,cv , 2/C DC CABLESco C 1 -PAIR, SINGLE MODE L ' ; I NOTES: 3, 4, 5, 13, 14 14. SEE DETAIL 1408 FOR DC POWER CABLE SIZES. • 0 FIBER CABLE IN 1 " LFNC �s �- - (TYP FOR 6) 15. DC SURGE PROTECTION CABINET SHALL BE RAYCAP DC6-48-60-0-1E. .c zc NOTES: 3, 4, 5, 13 s co SEE DETAIL 1464 FOR INTERNAL WIRING DIAGRAM. O w (TYP FOR 2) 1 " LFNC 16. FIBER & DC DISTRIBUTION BOX W/DC SURGE PROTECTION SHALL BE S 1 " NOTES: 3. 4, 6, 18 L FIBER FIBER RAYCAP DC6-48-60-18-8F. SEE DETAIL 1410 OR 1410B FOR INTERNAL 0 �0, 2/C DC CABLE IN LFNC (TYP FOR 6) 15 WIRING DIAGRAM. a Q NOTES: 3, 4, 5, 13, 14 _f= ALAR�� pp ® f 17. SUPPORT FIBER & DC POWER CABLES WITH SNAP-IN HANGERS SPACED °' (TYP FOR 2) �_ JUNCTION ALARM, CABLE - a E NO GREATER THAN 3 FEET APART ON TOWER. SUPPORT FIBER AND DC 0 NOTES. 3 4 5 FIBER m FIBER POWER CABLES INSIDE MONOPOLE WITH CABLE HOISTING GRIPS AT 250 FT o ' ' MAXIMUM INTERVALS. DRESS CABLES TO PREVENT CONTACT WITH ENTRANCE ° -° ° (2) 1 -PAIR, SINGLE MODE FIBER ---I -- F __i AND EXIT OPENINGS. o L- CABLES AND (2) 2/C DC CABLES IN W 18. CONDUIT TO BE USED ON A SELF SUPPORT TOWER IF THE RRH IS MORE T) 0_ CIU ? CD 6-1 THAN 10' FROM THE DISTRIBUTION UNITS. FEET. �, 1 " LFNC NOTES: 3, 4, 14 n MAX CABLE LENGTH IS 16 FIBER & POWER DISTRIBUTION ALCATEL-LUCENT 9412 19. SINGLE-CONDUCTOR DC POWER CABLES SHALL BE TELCOFLEX' • OR OPTIONAL INSTALLATION UNIT W/DC SURGE PROTECTION �, , BB TYPE 2 CABINET KS24194 ; COPPER, UL LISTED RHH NON-HALOGEN, LOW SMOKE WITH U E ONLYNOTEALARM CABLE FOR SECTOR A SEE DETAIL "A" THIS SHEET NOTES: 3, 4, 16, 26 WITH (1) 9926 (BBU) BRAIDED COVER, TYPE TC (1/0 AND LARGER). UNLESS OTHERWISE NOTED, ONLY NOTE: 22 (TYP FOR 3) AWG o O TOWER ) NOTES: 1 , 2, 5 STRANDING SHALL BE CLASS B (TYPE III) FOR CABLES SIZES 14, 12 & 10 O 73 DC6 - AWG AND CLASS I (TYPE IV) FOR SIZES 8 AWG AND LARGER. CABLES o NOTES: 3, 4, 17 SHALL BE COLOR CODED RED FOR +24V, BLUE FOR -48V AND GRAY FOR _ GPS ANTENNA & _ 24V AND 48V RETURN CONDUCTORS. MULTI-CONDUCTOR DC POWER EQUIPMENT LOCATED 18-PAIR, SINGLE MODE SURGE SUPPRESSORS CABLES SHALL BE COPPER, CLASS B STRANDING WITH FLAME RETARDANT �, AT GROUND LEVEL / FIBER FIBER CABLE IN 2" NOTES: 3, 4, 24 PVC JACKET, TYPE TC, UL LISTED FOR 90'C DRY/ 7FC WET INSTALLATION. - ° FIBER CABLES IN CONDUIT FLEXIBLE CONDUIT/INTERDUCT j 20. FOR GROUNDING WIRE SPECIFICATIONS SEE DETAIL 1008. - .-, •6 O +' NOTES: 3, 4, 6 21 . RET CONTROL FROM THE RRH IS AN OPTIONAL METHOD OF CONNECTION. -- c TYP I CAL PER SECTOR (NOTE: 22) 6/C DC CABLES - FIBER MGMT BOX ` REFER TO RF DATA SHEET FOR APPLICABILITY. NOTES: 3, 4, 14 NOTES: 3, 4 FIBER 0 q 0 p-I 22. FIBER OPTIC CABLES SHALL BE INSTALLED IN FLEXIBLE CONDUIT AS ▪ C D ETAI L Ar SCOPED BY MARKET. a o J (TYP FOR 2) 700 BAND & 1900 OR 0° E DC SURGE , 11 6 AWG 23. 4/0 NOTB EXCEED LENGTHFROM44 • 24V DC POWER PLANT TO 0 o PROTECTION CABINET 0 AWSE BBU 1 I 24. SEE DETAIL 1505 FOR GPS ANTENNA AND SURGE SUPPRESSOR COAXIAL .c NOTES: 3, 4, 15, 26 -1 . 6 AWG NOTES: 1 , 2, 5 1 -- 2 AWG - CABLE CONNECTION. v a� 25. SEE DETAIL 1150C FOR ALARM CABLE REQUIREMENTS. ° 0 (12) 1/C 12 AWG �� ) - - 26. NOTED EQUIPMENT MAY BE COMMON TO LTE AND UMTS SYSTEMS. REFER •0- a) n I1 -PAIR, SINGLE TO UMTS SYSTEM DIAGRAM IF APPLICABLE. a IN 2" LFMCM ABLE � J - - -C 1/C 1/0 AWG MODE FIBER ° o NOTES: 3, 4 (2) IN 2" al 15 NOTES: 1 , 2, 5 CLASS B ( 2) o LFMC CONDUIT TYP FOR E °' NOTES: 3, 4, 6 {- I-) C 48V DC BREAKER PANEL ALARM CABLE 2" LFNC CONDUIT LTE SYSTEM DIAGRAM, TOWER SITE v (2) 4/0 AWG IN (1) 100A NOTES: 1 , 2 SIAD ON/ PULL STRING) 47, ,� 2 1/2" IMC/RNC (6) 15A BREAKERS - - 66 BLOCK NOTES: 10, 26 , NOTES: 3, 4, 6 WITH OUTDOOR ALU BASEBAND a : CONDUIT NOTES: 3, 4, 8, 9 ____L_ _ i s ON TOWER '� NOTES: 3, 4, 23 I , AND R R H o :n (TYP FOR 2) \ -- NOTES: 3, 4 I C � � __ BY OTHERS �j - DETAIL 1400H 3 1 ALARM CABLES •o TO (2) 250A 24V TO -48V , I NTS E01 r- I- a BREAKERS IN CONVERTER NOTES: 3, 4, 25 1 0 = 24V DC POWER`, IN/ 2KW MODULES - --- 6 AWG NETWORK INTERFACE DEVICE 6 4u2 PLANT NOTES: 3, 4, 7 1- CHASSIS GND (VARIES BY MARKET) o -c: NOTE: 12 1 N0 - 2 AWG 1Q 2AWG 1 "4- -c OUTDOORCABINET - o � - J O c >, v 0) 0 0 a:t°g TC) �OFN'Ty SITE.., , : -c NAME: CUTCHOGUE �P� o� o. M°� °,pT''. 3 t&t m .6 -� BECHTEL ASSOCIATESENY1 271 06/12/15 L2C-ISSUED FOR CONSTRUCTION SB GS IM *: -, �� * •� ° PROFESSIONAL CORPORATION SITE NUIUIBER. NYC 00 11/13/14 L2C-ISSUED FOR CONSTRUCTION SB GS AN r- t- y I. ° cc SYSTEM DIAGRAM O E ° A UNIT OF BECHTEL CORPORATION 21855 COUNTY ROAD 48 !° &IR �„ I . Ili 4., 0 O 011 NO. DATE REVISIONS BY CHK APP'D Z ,a$ 2 _ _ -C °-0 1 5275 WESTVIEW DRIVE CUTCHOGUE, NY 1 1935 ��` r''� 1, JOB NUMBER DRAWING NUMBER REV •p' C L- SCALE AS NOTED ED BY: SB DRAWN BY: SB �,0 91807 ��. >,+; a FREDERICK, MD 21703-8386 USA IDESIGN I 9pESS10NP - - - - E01 O--c o BECHTEL DRG. NO.: 25736-415-CO-0000-01522 25736 415 LS L2C NYCENY1027 1 O •c O U 3 o la_ -t 41_,I l_i I- O '- •` a) Q O (2) lit - DC 1-700 I------I Tii -a O ° ALCATEL-LUCENT 1 POWER CABLES �,,r/ cc I I I m �' 9412 CABINET W/2 48V DC + GY 1 cr i r fr 1 ' DC2-1900 I I n _ BL ( I J z z 1 L----J RRH-A2 RRH-A1 9926 (SBU) INPUT 1 J J IX CL Z Z mmoo c5 0 D mmoo OC.) \ \ \ \ 1900 OR AWS 700 _c - o Y o x MY (NOTE: 11) (NOTE: 11) \ SECTOR A SECTOR A 3 v C m O m C m CE m cE m M m -- NOTE: 12 1 + i + i + 00 00 00 ' JUNCTION BOX 0 0 o eAM 700 ALARM � / 0 0 0 0 0 o rn rn 0) 0) 0) 0) (NOTE: 14) o o a-$5 JACKS ALARM SEE NOTE: 13 TYP - -c CABLE a ¢ m m r(T) r(T) al a m m Z Z ( ) 3 M 3 M o 0 2/C SHIELDED POWER Q) ALCATEL-LUCENT + x o w o w (BBU) U _ _ _ c ) c ) 0 o L a 0 o �.° 9926 48V DC _ o _ - + + CABLES 6 TYP NOTE: 6 Z °° z U °°°° °' 7001 Hz INPUT m �, ril_ic C + + + I-I± _ __- -� 3 m 6/C POWER CABLES SEE + -- 0 0 + - 0 0 ALARM 1 ` DC SURGE PROTECTION SHELF 0 (NOTE: 6) NOTE 16 Y o Y o JACKS RAYCAP DCS;-RM NOTES: 2, 8, 15 .\ SEE NOTE: 13 DC-A2-1900- (NP) , m w , m ct � FIBER PORTS GND ) o a, 1 2 3 4 5 6 Ti RJ45 _ - •.1.• - + - + - + - 6 AWG IcC? + cam) DC-A1-700• C° ❑ ❑ ❑ ❑ JACKS I -1+ `, l DI 4, 0 TAI - � � � � ALARM � / 0 oN TO EQUIP. JUNCTION BOX / CC r WHEN REQUIRED CABLE Cr � - CABINET o rJACKS (NOTE 9) (3 TrP) _ - _1 o eAM • • GROUND I I - - 2 AWG - 2 AWG • N BAR I I TO TO c Z 717 ` -- I GROUND GROUND -,-, 9926 (BBU) 48V DC{— -J >- -J >- -J >- -J >- -J >- -J >- L--- --ri mcD momcpmcDm _om_ o RRH-B2 RRH-B1 • • • AWS INPUT - ( - - - (12) 1/C POWER CABLES 1900 OR AWS 700 SECTOR B SECTOR B ° E m BL -° N 0 0 L- 1 2 3 4 5 6 T1 RJ45 <ci- ,, - ,_,-, P o ` ' C BK/BL BK - - o n_ w o a_ cc Z U O RD/BL + + RD J o o m a c� o ro a mommosagnmo " a • 1 1 1 -48V ` BK/BL + + BK J + 1 1 1 _ 0 0 + _ 0 0 RD/BL RD � UFjPORT - i (4) 1/C 4/0 AWG \ .. : - BK/OR DC6-1 BK m c m CI LSTAVD OV + FIBER & POWER + r 1 ; , Tv; ° POWER CABLES RD OR RD - • c, ;, 24V TO -48V CONVERTER / _ DISTRIBUTION - 1- I I `- NJ DC-B1-700 \ • 02 AWG ` BK/OR WITH BK -1-1,-.-\ I I �, LIJ a) � _ r � +24V INPUT +24V INPUT WITH + 48V SURGE PROTECTION + � -' 1 I � DC-B2-1900I o �' TO FEED A FEED B (NOTE: 3) INTEGRAL -48V BREAKER PANEL RD/OR _ RAYCAP DC6 _ RD J —� L---J , o \ . (NOTES: 2, 15, 17) BK/GN + BK _ GROUND NOTE: 3) RD GN (NOTES: 7, 15) ± RD 1 __.L. - 1 15c ' BK/GN + + BK TO TO -0 \ 2 AWG 2 AWG .�' c o o FACTORY t RD/GN RD \ ; 0 v ix p L-iaWIRING ALARM - `-, GROUND GROUND TERMINAL / 1 � ;, RRH-C2 RRH-C1 .� C +GND 0/P (NOTE: 4) (NOTE: 3) OV BLOCK 1900 SECTOR AWSC700 SECTOR C s o M_ =r1 - GND I/P a) v INSTALL (2) ERS ; ® q U U m E 250A BREAKERS�. 2AWG 6AWG ° 24V (NOTE: 10) (NOTE 5) ALARM CABLE rt`\` r- - --1 w o w o cT �_ 2 AWG 3 L'•- _ - TO 66 BLOCK — I ( Q.° , (+) TO E UIP. CABINET (THIS SHEET) TO I I o m o m_ Q I I z U Z U 5 0 a) NOTES: GND BAR GROUND cD o IL. a 0 o a + - " o OV I ° ® EVERY WIRE AND IN ANY PULL BOX IF USED. LABEL SHALL BE DURABLE, SELF ADHESIVE, DC-C2-1900 - 0 _-711'==:-.1 I o Q. o +, 1 1 . LABEL THE DC POWER CABLES AT BOTH ENDS OF _ CI) z 4' I WRAPPED LONGITUDINALLY ALONG THE CABLE AND STATE THE SECTOR, FREQUENCY BAND AND POLARITY; I.E. •A-AWS+•: CABLE AND WIRE _ II m I m o v, ' LABELS SHOWN ARE REPRESENTATIVE AND MAY BE MODIFIED AS DIRECTED BY MARKET. DC-C1 700 fX E .` PART OF DC POWER PLANT I CABINET. � ..ii 1 I ` 2. INSTALL IN AUXILIARY EQUIPMENT CA ° .c - 3. CABLE TERMINALS FOR +24V INPUT FEED A, FEED B AND REFERENCE GROUND SHALL BE 2-HOLE: 3/8" ON 1" CENTER. •- CRGB ' I 4. INSTALL CABLE TERMINALS FOR FEED A AND FEED B RETURN BACK-TO-BACK ON OPPOSITE SIDES OF PAD USING 1 -HOLE 3/8" TERMINALS. �, T:, , 5. CABLE TERMINALS FOR CHASSIS GROUND SHALL BE 2-HOLE, 1/4" ON 5/8" CENTER. - 2 AWG - G=2 AWG c 6. SEE DETAIL 1408 FOR DC POWER CABLE SIZES AND MAXIMUM LENGTH. TO TO ✓ �>, 7. SEE DETAIL 1410 OR 1410B FOR DC6 INTERNAL WIRING. CABLE GROUND WIRES NOT SHOWN FOR CLARITY. GROUND GROUND o 8. SEE DETAIL 1409 FOR DC6-RM INTERNAL WIRING. O o - •• 9. A JUNCTION BOX IS REQUIRED WHEN FIBER OPTIC CABLES ARE INSTALLED IN CONDUIT AS SCOPED BY MARKET. WIRING DIAGRAM, OUTDOOR 0 Z 10. CONVERTER REFERENCE GROUND IS NOT REQUIRED WHEN CONVERTER AND 24'V DC POWER PLANT ARE ON THE SAME RACK OR ENCLOSURE. a a) 11 . THE BARE WIRE OF EACH MULTI-CONDUCTOR CABLE AND DRAIN WIRE WHEN A SHIELDED CABLE IS USED, SHALL BE CONNECTED TO THE ALU BASEBAND AND RRHs ON TOWER/ROOFTOP, _, ~a a) EQUIPMENT CABINET GROUND BAR. U 12. SEE ALARM BLOCK ASSIGNMENT DETAIL FOR ALARM CABLE CONNECTIONS. DC/DC CONVERTER, DC6 (IC 13. WHEN A 1900 RRH IS USED INSTEAD OF AN AWS RRH CABLE LABELS SHOULD REFLECT CORRECT FREQUENCY BAND. 6? E 14. PROVIDE A JUNCTION BOX, AS SCOPED BY MARKET, TO COIL EXCESS DC POWER AND OPTICAL FIBER CABLES. (FIBER CABLES NOT SHOWN o ° _ FOR CLARITY.) DETAIL Allk A 1 w a 15. NOTED EQUIPMENT MAY BE COMMON TO LTE AND UMTS SYSTEMS. REFER TO UMTS SYSTEM DIAGRAM IF APPLICABLE. NTS E02 r +, _ • 16. CABLE GROUND WIRE AND SHIELD DRAIN WIRE TO BE LEFT UN-TERMINATED AT RRH. oN °,_j 17. SEE SYSTEM DIAGRAM OR DC PANEL SCHEDULE FOR BREAKER RATING. c J c La o c >, :1=1 ° :*' O• -c 0 Q.3 4 Z Q ‹, ()V NEW yp _ _ 3 at&t SITE NAME: CUTCHOGUE ��' a� "'°� aoi .N -° BECHTEL ASSOCIATES4.1 .1/4.2to....„ 1 06/12/15 L2C—ISSUED FOR CONSTRUCTION SB GS IM *� Q`' ,� T�� 00 o ` : PROFESSIONAL CORPORATION SITE NUMBER: NYCENY1027 �IA�' '�" t&it 0 11/13/14 L2C—ISSUED FOR CONSTRUCTION SB GS AN r:::::: � ��{�it ��W'' � w RRH WIRING DIAGRAM � � c r' ' � ORATION 21855 COUNTY ROAD 48 ! CHK � r � w ° o � A UNIT OF BECHTEL CORP No. DATE REVISIONS BY APP D ,� _ z -• a 7-5 n CUTCHOGUE, NY 1 1935 ��ul y� o c ° ��!' 5275 WESTVIEW DRIVE ' scALE: AS NOTED DESIGNED BY: SB DRAWN BY: SB .--76 X1807'\ ��`' JOB NUMBER DRAWING NUMBER REV C. ° ° FREDERICK, MD 21703-8386 USA „0 SOP 's'a E'SS�o 25736-415-LS L2C-NYCENY1027- E02 1 o 'c o BECHTEL DRG. NO.: 25736-415-CO-0000-01522 U 3 U L_ •Q o ELECTRICAL INSTALLATION NOTES (AS APPLICABLE) 25. WIREWAYS SHALL BE EPDXY-COATED (GRAY) AND INCLUDE A HINGED COVER, DESIGNED TO SWING OPEN DOWNWARD; SHALL BE A UIT TYPE E (OR EQUAL); AND RATED NEMA 1 (OR BETTER) INDOORS, OR NEMA 3R SYMBOLS �, a NOTES: (OR BETTER) OUTDOORS. c 1 . WIRING, RACEWAY, AND SUPPORT METHODS AND MATERIALS SHALL COMPLY WITH THE REQUIREMENTS VG SOLID GROUND BUS BAR m OF THE NEC AND TELCORDIA. 26. EQUIPMENT CABINETS, TERMINAL BOXES, JUNCTION BOXES, AND PULL BOXES SHALL BE GALVANIZED OR EPDXY-COATED SHEET STEEL, SHALL MEET OR EXCEED UL 50, AND RATED NEMA 1 (OR BETTER) INDOORS, OR NEMA 3R (OR BETTER) OUTDOORS 7 S/N SOLID NEUTRAL BUS BAR c = 2. SUBCONTRACTOR SHALL MODIFY EXISTING CABLE TRAY SYSTEM AS REQUIRED TO SUPPORT RF AND SUPPLEMENTAL GROUND CONDUCTOR L TRANSPORT CABLING TO THE NEW BTS EQUIPMENT. SUBCONTRACTOR SHALL SUBMIT MODIFICATIONS TO 27. METAL RECEPTACLE, SWITCH, AND DEVICE BOXES SHALL BE GALVANIZED, EPDXY-COATED, OR NON-CORRODING; SHALL MEET OR u) CONTRACTOR FOR APPROVAL. EXCEED UL 514A AND NEMA OS 1 ; AND RATED NEMA 1 (OR BETTER) INDOORS, OR WEATHER PROTECTED (WP OR BETTER) o'�0 2-POLE THERMAL-MAGNETIC o OUTDOORS. CIRCUIT BREAKER - 3. ALL CIRCUITS SHALL BE SEGREGATED AND MAINTAIN MINIMUM CABLE SEPARATION AS REQUIRED BY o 0 a a; THE NEC AND TELCORDIA. 28. NONMETALLIC RECEPTACLE, SWITCH, AND DEVICE BOXES SHALL MEET OR EXCEED NEMA OS 2; AND RATED NEMA 1 (OR BETTER) ^ SINGLE-POLE THERMAL-MAGNETIC 4. CABLES SHALL NOT BE ROUTED THROUGH LADDER-STYLE CABLE TRAY RUNGS. INDOORS, OR WEATHER PROTECTED (WP OR BETTER) OUTDOORS. 0 o CIRCUIT BREAKER .=• m m a 5. EACH END OF EVERY POWER, GROUNDING, AND Ti CONDUCTOR AND CABLE SHALL BE LABELED WITH 29. THE SUBCONTRACTOR SHALL NOTIFY AND OBTAIN NECESSARY AUTHORIZATION FROM THE CONTRACTOR BEFORE COMMENCING WORK ON 0 CHEMICAL GROUND ROD THE AC POWER DISTRIBUTION PANELS. 0 o COLOR-CODED INSULATION OR ELECTRICAL TAPE (3M BRAND, 1/2 INCH PLASTIC ELECTRICAL TAPE WITH UV GROUND ROD PROTECTION, OR EQUAL). THE IDENTIFICATION METHOD SHALL CONFORM WITH NEC & OSHA, AND MATCH 30. THE SUBCONTRACTOR SHALL PROVIDE NECESSARY TAGGING ON THE BREAKERS, CABLES AND DISTRIBUTION PANELS IN ACCORDANCE > EXISTING INSTALLATION REQUIREMENTS. WITH THE APPLICABLE CODES AND STANDARDS TO SAFEGUARD AGAINST LIFE AND PROPERTY. I DISCONNECT SWITCH c v of • 0 6. POWER PHASE CONDUCTORS (I.E., HOTS) SHALL BE LABELED WITH COLOR-CODED INSULATION OR 31 . LIQUID-TIGHT FLEXIBLE NON-METALLIC CONDUIT MAY BE USED WHERE NOTED ON DRAWINGS INDOORS AND OUTDOORS AND WHERE Q METER ..,_, oN ELECTRICAL TAPE (3M BRAND, 1,4 INCH PLASTIC ELECTRICAL TAPE WITH UV PROTECTION, OR EQUAL). PHASE NOT SUBJECT TO PHYSICAL DAMAGE. ALL FITTINGS SHALL BE PRESSURE TYPE, NOT GLUED. r ,..--- CONDUCTOR COLOR CODES SHALL CONFORM WITH THE NEC & OSHA AND MATCH EXISTING INSTALLATION o , REQUIREMENTS. 32. CABLES SHALL BE BUNDLED AND/OR SECURED TO THE CABLE RACK OF EQUIPMENT RACK USING 9-PLY WAXED POLYESTER TWINE ® CADWELD TYPE CONNECTION 4- 1- UNLESS PRIOR APPROVAL IS OBTAINED. 0 N 7. ALL ELECTRICAL COMPONENTS SHALL BE CLEARLY LABELED WITH ENGRAVED LAMACOID PLASTIC LABELS. COMPRESSION TYPE CONNECTION O z ALL EQUIPMENT SHALL BE LABELED WITH THEIR VOLTAGE RATING, PHASE CONFIGURATION, WIRE 33. NYLON CABLE TIES MAY BE USED FOR TEMPORARILY SECURING CABLES DURING THE INSTALLATION. PERMANENT USE OF NYLON GROUNDING WIRE CONFIGURATION, POWER OR AMPACITY RATING, AND BRANCH CIRCUIT ID NUMBERS (I.E., PANELBOARD AND CABLES TIES SHALL NOT BE USED UNLESS PRIOR APPROVAL IS OBTAINED FOR SECURING COAXIAL CABLES, OPTICAL FIBER CABLES, "0 CCIRCUIT ID'S). BATTERY CABLES AND CABLES TO DISTRIBUTION FRAMES OR ON CABLE RACKS. NYLON CABLE TIES MAY BE USED FOR SECURING 0 CD GROUNDING CONDUCTORS EXTERIOR TO SHELTERS AND EQUIPMENT ROOMS. U E o a 8. PANELBOARDS (ID NUMBERS) AND INTERNAL CIRCUIT BREAKERS (CIRCUIT ID NUMBERS) SHALL BE 34. NYLON CABLE TIES SHALL BE OF AN ADEQUATE SIZE, TYPE, STRENGTH, UV RESISTANT ETC. FOR THE PARTICULAR APPLICATION. ABBREVIATIONS rn CLEARLY LABELED WITH ENGRAVED LAMACOID PLASTIC LABELS. TAILS a)a SHALL BE TRIMMED TO WITHIN 1/32 INCH USING A TOOL SPECIFICALLY DESIGN FOR TENSIONING AND CUTTING NYLON CABLE TIES. AGL ABOVE GRADE LEVEL 9 9. DELETED o 0 10. POWER, CONTROL, AND EQUIPMENT GROUND WIRING IN TUBING OR CONDUIT SHALL BE SINGLE CONDUCTOR 1009 DETAIL AWG AMERICAN WIRE GAUGE CD o 0 (12 AWG OR LARGER), 600 V, OIL RESISTANT THHN OR THWN-2, CLASS B STRANDED COPPER CABLE RATED E03 SCALE: N.T.S. BCW BARE COPPER WIRE a FOR 90 'C (WET AND DRY) OPERATION; LISTED OR LABELED FOR THE LOCATION AND RACEWAY SYSTEM USED, SURGE SUPPRESSION NOTE: BTS BASE TRANSCEIVER STATION :(7, UNLESS OTHERWISE SPECIFIED. o (E) EXISTING 11 . SUPPLEMENTAL EQUIPMENT GROUND WIRING LOCATED INDOORS SHALL BE SINGLE CONDUCTOR (6 AWG OR NOTES: 0 = EG EQUIPMENT GROUND v o LARGER), 600 V, OIL RESISTANT THHN OR THWN-2 GREEN INSULATION, CLASS B STRANDED COPPER CABLE 1. RF SURGE ARRESTOR DEVICES SHALL BE INSTALLED IN ALL NEW ANTENNA & NEW COAXIAL INSTALLATION OR REPLACEMENTS. 0 -0 RATED FOR 90 'C (WET AND DRY) OPERATION; LISTED OR LABELED FOR THE LOCATION AND RACEWAY SYSTEM EGR EXTERNAL GROUND RING CDUSED, UNLESS, OTHERWISE SPECIFIED. o 1E 2. SEE DETAIL 1004 AND 1141 FOR ADDITIONAL RF COAXIAL SURGE ARRESTOR REQUIREMENTS. EMT ELECTRICAL METALLIC TUBING o c 12. SUPPLEMENTAL EQUIPMENT GROUND WIRING LOCATED OUTDOORS, OR BELOW GRADE, SHALL BE SINGLE C -v CONDUCTOR 2 AWG SOLID TINNED COPPER CABLE, UNLESS OTHERWISE SPECIFIED. 3. AC SURGE PROTECTION DEVICE (SPD) DEVICES FOR AC POWER SHALL BE INSTALLED FOR ALL NEW AC PANEL INSTALLATION OR GEC GROUNDING ELECTRODE CONNECTION •`) 0 REPLACEMENTS GEN GENERATOR o ° 13. POWER WIRING, NOT IN TUBING OR CONDUIT, SHALL BE MULTI-CONDUCTOR, TYPE TC CABLE (12 AWG OR GRC GALVANIZED RIGID CONDUIT -s o LARGER), 600 V, OIL RESISTANT THHN OR THWN-2, CLASS B STRANDED COPPER CABLE RATED FOR 90 'C 4. THE AC SPD SHALL BE COMMON MODE TYPE, MINIMUM RATED 120kA SURGE CURRENT, AND HAVE TTD 0W OTHERWISE DRY) SPEOPERATION; M ATION; WITH OUTER JACKET; LISTED OR LABELED FOR THE LOCATION USED, UNLESS MONITORING LIGHTS WITH FORM C ALARM CONTACTS. THE AC SPD SHALL BERAY CAP STRIKESORB TM TYPE, INNOVATIVE IGR INTERNAL GROUND RING (HALO) TECHNOLOGIES PTX120 OR OWNER APPROVED EQUAL. RAYCAP STRIKESORB SURGE PROTECTORS SHALL BE FACTORY INSTALLED IMC INTERMEDIATE METALLIC CONDUIT 0 0 IN THE PANELBOARD. OTHER MANUFACTURER SPD SHALL BE CONNECTED TO THE AC SYSTEM THROUGH A CIRCUIT BREAKER IN E 14. ALL POWER AND GROUNDING CONNECTIONS SHALL BE CRIMP-STYLE, COMPRESSION WIRE LUGS AND THE AC PANELBOARD AND SHALL BE MOUNTED INTEGRAL WITH THE PANELBOARD OR DIRECTLY ADJACENT. MGB MASTER GROUND BAR 0 °• WIRENUTS BY THOMAS AND BETTS (OR EQUAL). LUGS AND WIRENUTS SHALL BE RATED FOR OPERATION AT NO o22 *- LESS THAN 75'C (90'C IF AVAILABLE). 5. TELCO SURGE PROTECTION DEVICES SHALL BE INSTALLED IN ALL NEW Ti INSTALLATIONS (TYPE AS APPROVED BY AT&T MOBILITY). MIN MINIMUM °' 15. RACEWAY AND CABLE TRAY SHALL BE LISTED OR LABELED FOR ELECTRICAL USE IN ACCORDANCE WITH N.T.S. NOT TO SCALE ca- a) 6. THE SUBCONTRACTOR SHALL INSPECT THE EXISTING TELCO SYSTEM FOR PRESENCE OF SURGE PROTECTION AND REPORT FINDINGS 0 Cil NEMA, UL, ANSI/IEEE, AND NEC. PVC RIGID (SCH.40) POLYVINYL a o 2, 16. NEW RACEWAY OR CABLE TRAY WILL MATCH THE EXISTING INSTALLATION WHERE POSSIBLE. CHLORIDE CONDUIT -1-. 7. RAYCAP STRIKESORB TM SPD SHALL BE INSTALLED ON ALL DC CIRCUITS TO REMOTE RADIO UNITS/HEADS MOUNTED ON TOWER OR RBS RADIO BASE STATION -c E •°' 17. ELECTRICAL METALLIC TUBING (EMT) OR RIGID NONMETALLIC CONDUIT (I.E., RIGID PVC SCHEDULE 40, OR ROOFTOPS AND AS REQUIRED BY SITE SPECIFIC DESIGN DRAWINGS. o� , RIGID PVC SCHEDULE 80 FOR LOCATIONS SUBJECT TO PHYSICAL DAMAGE) SHALL BE USED FOR EXPOSED REF REFERENCE .c ..c INDOOR LOCATIONS. 8. SURGE SUPPRESSION AND PROTECTION DEVICES SHALL BE IN ACCORDANCE WITH THE REQUIREMENTS OF THE NATIONAL REQ REQUIRED v co ELECTRICAL CODE (NEC) ARTICLE 250, 280, 285, AND CHAPTER 8, AS APPLICABLE. RF RADIO FREQUENCY 2 18. ELECTRICAL METALLIC TUBING (EMT), ELECTRICAL NONMETALLIC TUBING (ENT), OR RIGID NONMETALLIC -a) .. CONDUIT (RIGID PVC, SCHEDULE 40) SHALL BE USED FOR CONCEALED INDOOR LOCATIONS. 100 DETAIL RGS RIGID GALVANIZED STEEL Ze= ; C 0 a 19. GALVANIZED STEEL INTERMEDIATE METALLIC CONDUIT (IMC) OR GALVANIZED STEEL OR ALUMINUM RIGID CONDUIT �, ti (RMC) SHALL BE USED FOR OUTDOOR LOCATIONS ABOVE GRADE. SIAD SMART INTEGRATED ACCESS 13 N TRANSPORT Ti LINES DEVICE C• a a) 20. RIGID NONMETALLIC CONDUIT (I.E., RIGID PVC SCHEDULE 40 OR RIGID PVC SCHEDULE 80) SHALL BE o N USED UNDERGROUND; DIRECT BURIED, IN AREAS OF OCCASIONAL LIGHT VEHICLE TRAFFIC OR ENCASED IN 1 . ALL RACEWAY SHALL COMPLY WITH THE REQUIREMENTS OF THE NATIONAL ELECTRICAL CODE (NEC, NFPA 70), CHAPTER 8. TBD TO BE DETERMINED REINFORCED CONCRETE IN AREAS OF HEAVY VEHICLE TRAFFIC. vi >w TBR TO BE RESOLVED •- o --g, 2. ALL SPECIFIED MATERIAL FOR EACH LOCATION (E.G., OUTDOORS, INDOORS-OCCUPIED, INDOORS-UNOCCUPIED, PLENUMS, RISER 111P TYPICAL N v L 21 . LIQUID-TIGHT FLEXIBLE METALLIC CONDUIT (LIQUID-TITS FLEX) SHALL BE USED INDOORS AND SHAFTS, ETC.) SHALL BE APPROVED, LISTED, OR LABELED AS REQUIRED BY THE NEC. I w a OUTDOORS, WHERE VIBRATION OCCURS OR FLEXIBILITY IS NEEDED. VIF VERIFY IN FIELD -., . • 3. METALLIC CONDUIT OR TUBING FOR Ti LINES SHALL BE BONDED TO GROUND AT BOTH ENDS. N c,;(2, 22. CONDUIT AND TUBING FITTINGS SHALL BE THREADED OR COMPRESSION-TYPE AND APPROVED FOR THE o LOCATION USED. SETSCREW FITTINGS ARE NOT ACCEPTABLE. 4. FOR NOKIA GSM BTS CABINET ONLY - THE Ti CABLE SHALL BE IDENTIFIED AT BOTH ENDS WITH A COMPUTER-PRINTED v SELF-LAMINATING POLYESTER WIRE MARKERS (BRADY CORP. OR EQUAL). USE THE "FROM" LOCATION FOLLOWING TYPICAL ID 1 ABBREVIATIONS & SYMBOLS e n f 23. CABINETS, BOXES, AND WIREWAYS SHALL BE LISTED OR LABELED FOR ELECTRICAL USE IN ACCORDANCE NAME AT THE NIU AND AT THE NOKIA BTS: 0-c 3 WITH NEMA, UL, ANSI/IEEE, AND NEC. E03 SCALE: N.T.S. v o 24. CABINETS, BOXES, AND WIREWAYS TO MATCH THE EXISTING INSTALLATION WHERE POSSIBLE. AT&T UMTS LEC CCT# zc , 15 •° -v BECHTELSITE NAME: CUTCHOGUE \�°0NAnwo at&t 3 ASSOCIATES P �o 4111 0° •F ca 0 Y PROFESSIONAL CORPORATION SITE NUMBER: NYCENY1027 "S � 1 06/12/15 L2C-ISSUED FOR CONSTRUCTION SB GS IM � �J,.- Tye a� o_ titpir A UNIT OF BECHTEL CORPORATION 21855 COUNTY ROAD 48 0 11/13/14 L2C-ISSUED FOR CONSTRUCTION SB GS AN r iN Oil o No. DATE REVISIONS w ELECTRICAL, TVSS NOTES, x-4-, " 1.71,,,,, � � ABBREV. & SYMBOLS •v, o 5275 WESTVIEW DRIVECUTCHOGUE, NY 11935 oNs BY CHK APP DL11 �nn .6 JOB NUMBER DRAWING NUMBER REV a 0 FREDERICK, MD 21703-8386 USA SCALE: AS NOTED I DESIGNED BY: SB I DRAWN BY: SB 0AR1801- �� oo 3 o BECHTEL DRG. NO.: 25736-415-00-0000-01522 °F>tss�°NP 25736-415-LS L2C-NYCENY1027- E03 1 _1:.L 1 /-\11_1 L L 161-p 6 AWG STRANDED Cu GROUNDING NOTES AS APPLICABLE INSULATOR WIRE PROVIDED WITH �' COAX GROUND KIT �.'- -- .� -v '! 4"x1/4" SOLID s H o NOTES: �r- j COPPER BAR 0° ' 1 . THE SUBCONTRACTOR SHALL REVIEW AND INSPECT THE EXISTING FACILITY GROUNDING SYSTEM AND (T) , 4 '2 '- <<-- J= o 0 LIGHTNING PROTECTION SYSTEM (AS DESIGNED AND INSTALLED) FOR STRICT COMPLIANCE WITH THE NEC l -oF " ( " 5 GROUND BAR ON - - __ - . (AS ADOPTED 13Y THE AHJ), THE SITE—SPECIFIC (UL LPI, OR NFPA) LIGHTNING PROTECTION CODE, AND — ` 130r _ ._ ._pROP T = r/ ; WALL, FLOOR COMPLIANCE WITH TELCORDIA AND TIA GROUNDING STANDARDS. THE SUBCONTRACTOR SHALL i pT v GENERAL _ -UIRED OR ON ANTENNA ,,c REPORT ANY VIOLATIONS OR ADVERSE FINDINGS TO THE CONTRACTOR FOR RESOLUTION. _ / \ / \ \' t _ =N AS RE TOWER T 1 ,..._ ,_( _ \' 0 1-,i T LENGt ' r - '.°� GROUND ELECTRODE SYSTEMS (GES) (INCLUDING TELECOMMUNICATION, RADIO, LIGHTNING PROTECTION, �` �` ��� ' �� �\ _ 2. ALL -' STAINLESS STEEL -' ' ' ' -' ' . ? AND AC POWER GESS) SHALL BE BONDED TOGETHER, AT OR BELOW GRADE, BY TWO OR MORE COPPER -- 1 V 3 _ - a) HARDWARE ••� lP �` �� I I 0 m BONDING CONDUCTORS IN ACCORDANCE WITH THE NEC. ` ' ' ' ' (NOTE: 1) �i - ) )' ��� _�/ -_�� N 1 ma) I w 3. THE SUBCONTRACTOR SHALL PERFORM IEEE FALL—OF—POTENTIAL RESISTANCE TO EARTH TESTING (PER IEEE EACH GROUND CONDUCTOR TERMINATING ON ANY GROUND BAR SHALL HAVE J 1100 AND 81) FOR NEW GROUND ELECTRODE SYSTEMS. THE SUBCONTRACTOR SHALL FURNISH AND AN IDENTIFICATION TAG ATTACHED AT EACH END THAT WILL IDENTIFY ITS r - INSTALL SUPPLEMENTAL GROUND ELECTRODES AS NEEDED TO ACHIEVE A TEST RESULT OF 5 OHMS OR ORIGIN AND DESTINATION. EXOTHERMIC WELD c° LESS. TESTS SHALL BE PERFORMED IN ACCORDANCE WITH PROJECT PROCEDURES FOR TESTING OFANGLE SHOWN TO ILLUSTRATE WELD FACILITY GROUNDING FOR CELL SITES. CONNECTION FOR: (WELDING PROHIBITED AT THE LOWEST POINT ON THE BAR. o COAXIAL CABLE SHIELD COAXIAL CABLE SURGE SUPPRESSORS ON ROOFTOPS) PLACE WELD AT BOTTOM CENTER o 4. METAL RACEWAY SHALL NOT BE USED AS THE NEC REQUIRED EQUIPMENT GROUND CONDUCTOR. STRANDED CABLE ENTRY PORTS (HATCH PLATES) RECTIFIER FRAMES - WHERE BAR IS MOUNTED HORIZONTAL. EF,- COPPER CONDUCTORS WITH GREEN INSULATION, SIZED IN ACCORDANCE WITH THE NEC, SHALL BE 24V & 48V DC POWER RETURN BAR GENERATOR FRAME WORK 2 AWG SOLID BARE TINNED o FURNISHED AND INSTALLED WITH THE POWER CIRCUITS TO BTS EQUIPMENT. TELCO GROUND BAR MASTER GROUND BAR COPPER GROUND CONDUCTOR. >o NOTE: EXOTHERMIC WELD TO BURIED GROUND 5. DELETED DETAIL NOTES: 0 RING AND GROUND BAR v o •� z 6. EXOTHERMIC WELDS SHALL BE USED FOR ALL GROUNDING CONNECTIONS BELOW GRADE. 1 . BOLT HEAD SHALL BE FACING OUT, BOLTING SEQUENCE: -v c 1 . TWO—HOLE, LONG BARREL COMPRESSION LUG WITH 2 AWG STRANDED • OLT HEAD S E 7. APPROVED ANTIOXIDANT COATINGS (I.E., CONDUCTIVE GEL OR PASTE) SHALL BE USED ON ALL COPPER CONDUCTOR AND GREEN THW/THWN SUNLIGHT RESISTANT • FLAT WASHER o a COMPRESSION AND BOLTED GROUND CONNECTIONS. INSULATION TO GROUND BAR. ROUTE CONDUCTOR AS APPLICABLE TO • LUG L_ �, BURIED GROUND CONDUCTOR OR MASTER GROUND BAR AND CONNECT • BAR L Q 8. ICE BRIDGE BONDING • CONDUCTORS SHALL BE EXOTHERMICALLY BONDED OR BOLTED WITH STAINLESS WITH TWO—HOLE LUG TO "P" SECTION. • FLAT WASHER L_ ° STEEL HARDWARE TO THE BRIDGE AND THE TOWER GROUND BAR. • LOCK WASHER c 2. USE PERMANENT MARKER TO LABEL THE WHOLE BAR AS "P" WITH 1 " • NUT C' 9. ALUMINUM CONDUCTOR OR COPPER CLAD STEEL CONDUCTOR SHALL NOT BE USED FOR GROUNDING HIGH LETTERS. o W CONNECTIONS. INSTALLATION OF GROUND WIRE o a. 3. FOR GROUND BAR LOCATED OUTDOORS, ON—GRADE ONLY, 1 1429 TO COAX CABLE GROUND BAR DETAIL La 4, 10. MISCELLANEOUS ELECTRICAL AND NON—ELECTRICAL METAL BOXES, FRAMES AND SUPPORTS SHALL BE EXOTHERMICALLY WELD A 2 AWG BARE TINNED COPPER CONDUCTOR TO a BONDED TO THE GROUND RING, IN ACCORDANCE WITH THE NEC. GROUND BAR AND EXOTHERMICALLY WELD TO BURIED GROUND E04 SCALE: N.T.S. E CONDUCTOR. S 0 11 . METAL CONDUIT AND TRAY SHALL BE GROUNDED AND MADE ELECTRICALLY CONTINUOUS WITH LISTED TO TOWER MOUNTED AMPLIFIER UNITS (TMA) (WHERE o -o BONDING FITTINGS OR BY BONDING ACROSS THE DISCONTINUITY WITH 6 AWG COPPER WIRE UL APPROVED 4. GROUND BARS SHALL BE TINNED COPPER AND SHALL BE ENGRAVED OR APPLICABLE) AND RECEIVE ANTENNA PORTS -° GROUNDING TYPE CONDUIT CLAMPS. o IMPRESSED STOLEN—DO NOT RECYCLE" AND/OR "PROPERTY OF AT&T", -;-, c 12. GROUND CONDUCTORS USED IN THE FACILITY GROUND AND LIGHTNING PROTECTION SYSTEMS SHALL NOT ETCHED OR STAMPED WITH SITE FA LOCATION AND SECURED WITH TO TRANSMIT ANTENNA PORT c BE ROUTED THROUGH METALLIC OBJECTS THAT FORM A RING AROUND THE CONDUCTOR, SUCH AS ANTI—THEFT HARDWARE. __.__ I to METALLIC CONDUITS, METAL SUPPORT CLIPS OR SLEEVES THROUGH WALLS OR FLOORS. WHEN IT IS o ° REQUIRED TO BE HOUSED IN CONDUIT TO MEET CODE REQUIREMENTS OR LOCAL CONDITIONS, © 1124 SUPPLEMENTAL/SECTOR GROUND BAR RX1/RX2 TX TX RX1/RX2 TX C c NON-METALLIC MATERIAL SUCH AS PVC PLASTIC CONDUIT SHALL BE USED. WHERE USE OF METAL _ 00 CONDUIT IS UNAVOIDABLE (E.G., NON—METALLIC CONDUIT PROHIBITED BY LOCAL CODE) THE GROUND E04 SCALE: N.T.S. ri\ s o CONDUCTOR SHALL BE BONDED TO EACH END OF THE METAL CONDUIT. �-, 0�� m ° 13. ALL TOWER GROUNDING SYSTEMS SHALL COMPLY WITH THE REQUIREMENTS OF ANSI/TIA 222. FOR TOWERS E o a BEING BUILT TO REV G OF THE STANDARD, EXCEPT THE WIRE SIZE OF THE BURIED GROUND RING AND JUMPER REQUIRED ONLY FOR rill r-ice r � c CONNECTIONS BETWEEN THE TOWER AND THE BURIED GROUND RING SHALL BE 2 AWG AND THE MINIMUM EASE OF CONNECTION (TYP) I • I I r� I I I WEATHERPROOFING KIT o.� LENGTH OF THE GROUND RODS SHALL BE 8 FEET. 12" TO 24" I I I • I I I (NP) AND STRESS REDUCTION ON �I I 11 I I I ANTENNA CABLE ---� _ _____ __ L__�� L-1J I _)J- ANTENNA CONNECTORS �'.a 14. GROUND BARS SHALL BE TINNED COPPER AND SHALL BE ENGRAVED OR IMPRESSED "STOLEN—DO NOT r1--Ir r _ RECYCLE" AND/OR "PROPERTY OF AT&T", ETCHED OR STAMPED WITH SITE FA LOCATION AND SECURED \ , °- p WITH ANTI—THEFT HARDWARE. WEATHERPROOFING KIT LJ I STANDARD GROUND KIT (TTP) o (NOTE: 3) L L J (NOTE: 1) v c 15. GROUND WIRING LOCATED INDOOR OR IN CONDUIT SHALL BE SINGLE CONDUCTOR, 600V, GREEN INSULATED EQUIPMENT rrn — CABLE GROUND KIT SIDE• CONNECTOR - '--' = - s , , �- UL LISTED TYPE THHN/THWN OR RRH, ANNEALED, TINNED OR UN TINNED CLASS B OR CLASS I STRANDED � WEATHERPROOFING KIT (TTP) /• ANTENNA CABLE TO BTS (TTP) — a) COPPER, SIZE 6 AWG UNLESS OTHERWISE SPECIFIED. 6 AWG STRANDED Cu WIRE WITH __ SUNLIGHT RESISTANT GREEN, 600V `% '� ,v v 16. BURIED GROUND WIRE AND WIRES CONNECTED TO THE BURIED GROUND WIRE SHALL BE BARE, SOFT OR INSULATION OR AS PROVIDED WITH' a 2—HOLE COMPRESSION `•�_/'`�`,`,` 6 AWG STRANDED Cu WIRE c -c HARD—DRAWN, SOLID TINNED COPPER, SIZE 2 AWG UNLESS OTHERWISE SPECIFIED. GROUND KIT (NOTES: 1 & 2) LUG TO GROUND BAR C . .,�� • % SUPPLIED WITH KIT OR WITH -v ">, NOTES: ` GREEN, 600V, SUN RESISTANT tiE L 17. GROUND WIRING INSTALLED OUTDOOR EXPOSED SHALL BE 600V, GREEN SUNLIGHT RESISTANT UL LISTED FROM TMA AND v , - _- ---- -- INSULATION o o TYPE THW OR THWN OR XHHW, ANNEALED• , TINNED OR UN—TINNED CLASS B OR CLASS I STRANDED 1 . DO NOT INSTALL CABLE GROUND KIT AT A BEND AND ALWAYS OTHER EQUIPMENT I w COPPER, SIZE 6 UNLESS OTHERWISE SPECIFIED. DIRECT GROUND WIRE DOWN TO GROUND BAR. (WHERE APPLICABLE) ,� z GROUND BAR, DETAIL 1197 c - co 2. GROUNDING KIT SHALL BE TYIPE AND PART NUMBER AS NOTES: IJUIIIII MOUNTED NEAR/BELOW ANTENNA C) = SUPPLIED OR RECOMMENDED BY CABLE MANUFACTURER. BONDED TO TOWER STEEL OR _ 1 . DO NOT INSTALL CABLE GROUND KIT AT MONOPOLE. DOWN CONDUCTOR Lri > t A BEND AND ALWAYS DIRECT GROUND TO GROUND NOT REQUIRED. o sa .c' 3. WEATHERPROOFING SHALL BE (TYPE AND PART NUMBER) AS •• (\I v SUPPLIED OR RECOMMENDED BY CABLE MANUFACTURER AND WIRE DOWNWARD. -__ .q.,--_� a APPROVED BY CONTRACTOR. 2. SEE DETAIL 1197 FOR LUG ATTACHMENT. oN o,J ' 2 AWG Cu STRANDED WIRE WITH c CONNECTION OF CABLE GROUND CONNECTION OF GROUND WIRE GREEN, soov, SUN RESISTANT ° c A DETAIL A 1 139 KIT TO ANTENNA CABLE TO GROUNDING BAR INSULATION TO SITE GROUND :� v .- 1008 v -4-, - Cil E04 140 (TOWER/MONOPOLE/ROOFTOP) (ROOFTOP SITES) L. 2 E04 SCALE: N.T.S. SCALE: N.T.S. o o E04 SCALE: N.T.S. z -, . Q OF NEIN •° -v BECHTEL ASSOCIATES SITE NAME: CUTCHOGUE ,s o\) o. MOG,,op 3 a$&$ m cn c 1 06/12/15 L2C-ISSUED FOR CONSTRUCTION SB GS IM � �`� ejli0 -- -v„• 0 PROFESSIONAL CORPORATION SITE NUMBER: NYCENY1027 `� * �� ao C� • I 0 11/13/14 L2C-ISSUED FOR CONSTRUCTION sB cs AN r- . W GROUNDING NOTES & DETAILS ` 21855 COUNTY ROAD 48 iiii � 51:1621,,;41-4-+, a o :� `N��++ A UNIT OF BECHTEL CORPORATION No. DATE REVISIONS BY CHK APP'D • v V` 7 5275 WESTVIEW DRIVE CUTCHOGUE, NY 11935 y 'c a) p SCALE: AS NOTED DESIGNED BY: SB DRAWN BY: SB • g7�07'1 �� JOB NUMBER DRAWING NUMBER REV ,,4' a FREDERICK, MD 21703-8386 USA AR Z4� P� �� o C `p BECHTEL DRG. NO.: 25736-415-00-0000-01522 °FESS40N 25736-415-LS L2C-NYCENY1027- E04 1 U 3 U JI[_L _ _ J-I Al I'_,I U