Loading...
HomeMy WebLinkAbout40208-Z sUEQI'�C�G , Town of Southold 3/4/2016 a P.O.Box 1179 _ 53095 Main Rd 4,1 �4�. Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 38131 Date: 3/4/2016 THIS CERTIFIES that the building RESIDENTIAL ALTERATION Location of Property: 70 Deep Hole Dr, Mattituck SCTM#: 473889 Sec/Block/Lot: 115.42-2 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 10/14/2015 pursuant to which Building Permit No. 40208 dated 10/26/2015 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: interior alterations to an existing one family dwelling as applied for The certificate is issued to Randon,Thomas&Bucaille,Alice of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 40208 2/24/2016 PLUMBERS CERTIFICATION DATED 02-16-2016 George Fredricks Auth ' ed ignatur z1�z TOWN OF SOUTHOLD ay BUILDING DEPARTMENT TOWN CLERK'S OFFICE oy . o�� SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 40208 Date: 10/26/2015 Permission is hereby granted to: Diaz, Carol 11 Andover Dr Bohemia, NY 11716 To: construct interior alterations to an existing single family dwelling as applied for. At premises located at: 70 Deep Hole Dr, Mattituck SCTM # 473889 Sec/Block/Lot# 115.-12-2 Pursuant to application dated 10/14/2015 and approved by the Building Inspector. To expire on 4/26/2017. Fees: SINGLE FAMILY DWELLING -ADDITION OR ALTERATION $416.00 CO -ALTERATION TO DWELLING $50.00 $466.00 Building Inspector - - Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings,property lines,streets,and unusual natural or topographic features. 2. Final Approval from Health Dept.of water supply and sewerage-disposal(S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of I%lead. 5. Commercial building,industrial building,multiple residences and similar buildings and installations,a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings(prior to April 9, 1957)non-conforming uses,or buildings and"pre-existing"land uses: 1. Accurate survey of property showing all property lines,streets,building and unusual natural or topographic features. 2. A,properly completed application and consent to inspect signed by the applicant.If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00,Alterations to dwelling$50.00, Swimming pool$50.00,Accessory building$50.00,Additions to accessory building$50.00,Businesses$50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy-$.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy-Residential$15.00,Commercial$15.00 . te. /a -- i�--r✓ /a New Construction: Old or Pre-existing Building: (check one) Location of Property: -70 4iL�—f' AA0Z4== 02 House No. Street Hamlet Owner or Owners of Property: �l1t7M 424rXJooxi ¢ .�S L/G� RUG�i LLQ Suffolk County Tax Map No 1000,Section l/4Z Block !L; Lot e5:702,O/-_)o Subdivision Filed Map. // Lot: Permit No. �cJ Date of Permit. Applicant: *&14� l etl+e//Ii:2� Health Dept.Approval: Underwriters Approval: Planning Board Approval: / Request for: Temporary Certificate .Final Certificate: V (check one) Fee Submitted:$ pplicant Signature ®F sovey®�® Town Hall Annex Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 1179 G ® roger.riche rto_town.southoId.ny.us Southold,NY 11971-0959 ®lyC®UNT1,� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION Issued To: Randon (Diaz) Address: 70 Deep Hole Drive City: Mattituck St: New York Zip: 11952 Budding Permit#• 40208 Section: 115 Block: 12 Lot: 2 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: MJM Electric Corp. License No: 42868-ME SITE DETAILS Office Use Only Residential X Indoor X Basement X Service Only Commerical Outdoor X 1st Floor X Pool New Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt 4 Ceiling Fixtures HID Fixtures Service 3 ph Hot Water GFCI Recpt 5 Wall Fixtures 6 Smoke Detectors 3 Main Panel 200A A/C Condenser Single Recpt Recessed Fixtures 15 CO Detectors Sub Panel A/C Blower Range Recpt Fluorescent Fixture Pumps Transformer Appliances DW Dryer Recpt Emergency Fixtures Time Clocks Disconnect Switches 7 Twist Lock Exit Fixtures 11 TVSS Other Equipment: Install New 200A Panel Board, 2- Combination Smoke/CO- Detectors. 1-40A Oven,1-40A Cook Top,3-ARC Fault Circuit Breakers. Notes Inspector Signature: c,r_r® _ Date: February 24, 2016 Electrical 81 Compliance Form As SOU������Fl Town Hall Annex Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 1179 Southold,NY 11971-0959 BUILDING DEPARTMENT TOWN OF SOUTHOL FF9 16 2016 < - - - - -- CIERTI FICATION Date: Building Permit No. l! d Owner: (Please print) // Plumber:___ �9� 1q—ed zC`` t (Please print) I certify that the solder used in the water supply system contains less than 2/10 of 1% lead. zzz`II nQ (PIumbers Signature) Sworn to before me this day of AY'1kG,! j 20_t�, - Notary Public, l,( J f ' - C OL111ty CONNIE D.BUNCH Notary Public,State of New York No.01 SU61 85050 Wuallfied in Suffolk County Commission Expires April 14,2 D) 11 OF SObTy�lo . cOUNi`I,� TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECT NL [ ] FO DATION 1 ST [ ROUGH PLUMBING [ ] UNDATION .2ND [ ] INSULATION ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE A CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] CAULKING REMARKS: i _,17 z r S DATE �� INSPECTOR y� � � �O��OF SOUlyolo TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECT [ ] FOUNDATION 1 ST [ RO H PLUMBING [ ] FOUNDATION 2ND [ NSULATION [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE A CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT'PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] CAULKING REMARKS: �. 44 DATE �" �" �� INSPECTOR CA s cou TOWN,OF SOUTHOLD BUILDING"DEPT. 765-1802 JNSPECTION �-' I FOUNDATION I ST R GH PLUMBING FOUNDATION 2ND 7INSULATION. FRAMING / STRAPPING FINAL FIREPLACE & CHIMNEY FIRE SAFETY INSPECTION FIRE RESISTANT CONSTRUCTION FIRE RESISTANT PENETRATION ELECTRICAL (ROUGH) ELECTRICAL (FINAL) CODE VIOLAT!qN CAULKING REMARKS: A3 DATE 017 IIJ INSPECTOR COT OF SOUryolo . co TOWN 'OF SOUTHOLD BUILDING DEPT. 765-1802 I NSPECTION [ ] FOUNDATION 1-ST [ ] ROUGH PLUMBING [ ] FOUNDATION 2ND [ ] INSULATION [ ] F MING /STRAPPING [ ] FINAL [ FIREPLACE A CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] CAU I NG- REMARKS: DATE "a INSPECTOR �_ r ,, OF SO(/T�OIo c0UN1`I,N TOWN OF-SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION" [ ] FOUNDATION-1ST [ ] ROUGH PLUMBING [ ] FOUNDATION 2ND [ ] IN TION [ ] FRAMING /STRAPPING [ FINAL [ ] FIREPLACE A CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] CAULKING REMARKS: NrV, i DATE / INSPECTOR TOWN OF "SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION IST [ ] ROUGH PLUMBING [ ] FOUNDATION 2ND [ ] INSULATION- [ ] FRAMING / STRAPPING [ ] FINAL [ ] FIREPLACE A CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) 1�1 ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] CAULKING REMARKS: DATE ��O INSPECTOR c r Ai • % ✓ / wl ASK- ✓~ ^ MA I oil � t •r ■ TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUEL-DING-DEPARTMENT- - - - - Do you have or need'the following;before applying? TOWN HALL Board of Health SOUTHOLID;'NY 11971 - - 4 _ '-` '4'sets of Building"Plans' TEL: (631)765-1802 - - ' ' __ _ _ -Planning Board approval_ r' ' FAX: (631)-76544'2Survey SoutholdTown.NorthFork.net -PERMIT NO.;• f3 0p--- - Check Septic Form t; _ii . , � . . rr <ir �;'�tt ; , ,. '• '�'N.Y.S:D.E:C.�rr - - r+ - ,' r; - - - Trustees. - - C.O.Application - Flood Permit Examined 20 Single'&Separate' Storm-Water Assessment Form Approved ,20 Mail to:' ��26� Disapproved a/c Phone: 4® (.4y 2-` Expiration ;20• - . .. - _ .`: . c; xBuilding Insp ctor , !n� APP ON FOR,BUILDING.PERMIT 14 2015 .. ;. ; , Date / -.� - 20 l ;;.. . .., INSTRUCTIONS a.This a plica 1 __- fSf'bekcom let' " 'derby typewriter oi'in ink and submitted to the Building Inspector with'4- sets of plans,acc to plot plar�-to s a e.Fee according to schedule. b:Plot 1 s owin location'of lot atiYd ofliiiildiri` ori remises,'relationshi to ad'oinin remises'or ublic streets''or p g P P J gP P areas,and waterways. _ c.The',work-covered by,this application may-not be'-commenced.before issuance.of Building�Permit:' d.-Upon approval of'thi's application,the-Building Inspector'will issue a Building Permit to-the applicant.Such a•permit shall be kept on the premises available for-ins ctionthroughout the4ork. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f.Every building permitishall,cxpire if,the work authorized-has not commenced within 12months,after,the date of issuance or has not been completed within 18 months from such date.If no,zo!Opmendments,or other,regulations affecting the property have been enacted in the interim,the Building Inspector may authorize0n writing,the.,extension of the permit for ari addition six months.Thereafter,a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant,to the Building Zone Ordinance of the Town of Southold,'Suffolk County,New''York;'and other applicable'Laws,Ordinances or Regulations,for the construction of buildings,additions,or alterations or for removal or demolition as herein described.The applicant agrees=to'comply''with`all applicable`lawn,-oidinances,,6nilding code,housing code,and regulations;andto admit '' ' authorized inspectors on premises and in building for necessary inspections. (Signature of applicant or name,if a corporation) (Mailing address of applicant) State whether applicant is owner;lessee;`agent-•architect;engineer;'general contractor,•electrician,plumber or builder Name of owner of premises ,,. (As on the tax(roll or,latest;deed) . If applicant is a corporation, signature of,duly authorized officer. ,1 „ • ;; � .rI3 sit.t i:.1;}f .`3 � .t. ..r 1✓r, ft. ., t� '. , .J..,.— , - t• (Name and title of corporate officer) Builders License No. G=6z Plumbers License No. Electricians License No. Other Trade's-License No. - - - = 1. Loccaatt)ion of land on which proposed �work /will be/done: � _2 r, House Number Street County Tax Map No. 1000 Section 1/-415 Block a. Existing use and occupancy 2_iE5 e�EUVRe__ t, ,- I I I- �, IF", 1 -1, , _' __ - b. Intended use,and;occupancy 3. Nature of w&k,(c4eckwhich applicable):New Building Addition Atterath Repair Removal Demolition _Other Work l{+ espnpt.ion 4. Estimated Cost i Fee , z Cf (To`be Q'tfiis on fifl 5. lf&ie1jing,number of dwelling,units _Number of dwelling units on each floor If garage, number of.cars 6. If business,commercial'or-mixed occupancy,specify nature and extent of each type of use. Depth 7. Dimensions of6 mi"g"s structures,if any:Front Rear Height le? 67' Number of Stories e-V 4;7 Di me'nsions" of same structure with alter*/.'alterations or additions: Front. Wear 5f ,1�� Depth -Heightle-2. Number of Stories— I " 8. Dimensions of entire new construction: Depth Height Number of Stories 9. Size of lot:Front 126'.60`3 -_---Rear epth /07 10.Date of Purchase 4 V, 1 ' "2 -7/ 4-1 , ,,N dfFonndf Om4ierV n.-Zone or use district ln-Whi c�h premises are situated �2 Tn,A 12.,Does p�?posed construction violate,any,zoning law,ordinance.or regulation?YES NOVI d ,premises?YES YES NOZIF�11'excqss fill tie remove 13. ill.lot bere grOWI 14.Names of Owner of —.premises, •No. 5?177.2477-31�24_ Name ofArchitect, Ail Address-P0.13W6,, Phone No 6'41.472,-Xk 2q- Name of Contractor ZPAkr "/Zi Address U, Phone No: ,jl/. 5!a.' ,i 10 15 a.Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES��_, * IF YES; SOUTHOLD'TOW-N"TRUSTEE-S'&D.EI.C:"PERMIT§MAY BEREQUIRED, property, IF YE'S,'D.t.C.' PERMITS" 9ERE0tflRED_.` 16.Provi&,� 'eX',.,-t-os'c�l�,,,wlih,accuratef6tifidati6iip!an'��dOP ista���sto-p ertvlifids'. ',, , , 17.If elevation:At,,arIy.point on property is,at,10 fqq qr,bqlqw,,Tp§t,prgvidp,tqppgrap �hical data on survey." 18.Are there any covenants and restrictions with respect to this property? YES NO V IF YES,PROVIDE A COPY. STATE OF NEW YORK) S- COUNTY OF,;-, (Name of individual signing contract)above named, (S)He is the-- (Contractor,Agent,Corporate Qffiqerl etc.), of said owner or owners,and is duly iutfi6fiiia 10 jeff6Iriri of hivie'pefformed the said work and to make and file this application; that all statements contained in this application are true to the'bckoithiAno'w hylgd aAd bdli6f;And that the work will be performed in the manner set forth in the application filed therewith. 11*A5--I,-I Sworn to before me this day of 4*,&er_ 20_1!SL7 Cj Notary Pub jq Signature of Applicant TRA0EY-L_DWYER_,_­ NOTARY PUBLIC,STATE OF NEW YORK':, NO.OIDW6306900 QUALIFIED IN SUFFOLK COUNTY COMMISSION EXPIRES JUNE 30,2!n- Scott A. Russell ,�a®su �� ST011L' lA�l WA.,T]E]R. SUPERVISORMA NA\cG►]EMENT SOUTHOLD TOWN HALL-P.O.Box 1179 53095 Main Road-SOUTHOLD,NEW YORK 11971Town of Southold CHAPTER 236 - STORMWATER MANAGEMENT WORK SHEET (TO BE COMPLETED BY THE APPLICANT ) DOES TMS PROJECT EC T INVOLVE ANY of THE FOLLOWING Yes NO (CHECK ALL THAT APPLY) []VA. Clearing, grubbing, grading or stripping of land which affects more than 5,000 square feet of ground surface. ❑ V . Excavation or filling involving more than 200 cubic yards of material within any parcel or any contiguous area. ❑[K. Site preparation on slopes which exceed 10 feet vertical rise to 100 feet of horizontal distance. ❑[ . Site preparation within 100 feet of wetlands, beach, bluff or coastal VE. erosion hazard area. ❑ Site preparation within the one-hundred-year f loodplain as depicted on FIRM Map of any watercourse. ❑[ . Installation of new or resurfaced impervious surfaces of 1,000 square feet or more, unless prior approval of a Stormwater Management Control Plan was received by the Town and the proposal includes i in-kind replacement of impervious surfaces. If'you answered NO to all of the questions above, STOP! Complete the Applicant section below with your Name, Signature, Contact Information, Date & County Tax Map Number! Chapter'236'does not apply to your project. If you answered YES to one or more of the above,please submit Two copies of a Stormwater Management Control Plan and a completed Check List Form to the Building Department witgyour Building Permit Application. APPLICANT (Property, ner Design Professional,Agent,Contractor,Other) S.C.T.M. #: 1000 Date. I Dutrut f y� NAME- � L �/Joey.66)0 Alff1 Section Block Lot ff `' n �***FOR BUILDIN TMENT USE ONLY**** Contact Information I ' 7� 2 (telephone Numhnl Reviewed B� — — — — — — — — — — — — — — — — G 'Date: �� � Property Address/Location of Construction Work: — — — — — — — — — — — — — �� GE pproved for processing Builth g Permit. / tormwatei Management Control Plan Not Required. Stormwater Management Control Plan is Required (Forward to Engineering Department for Review.) FORM # SMCP-TOS MAY 2014 i i o��oF sa�ryo! � o Town Hall Annex Telephone(631)765-1862 54375 Main Road �F765'.&12. P.O.Box 1179 G Q raaer.richert(a,own so &ny.us Southold,NK 11971-0959 Q �O ��OOUNTI,�c� BUILDING DEPARTMENT TOWN OF SOUTHOLD j APPLICATION FOR ELECTRICAL INSPECTION REQUESTED BY. tt ,� p . ��tc.�e�lA � J t � Date: Company Name: MS CxV (J Name: W\ I License No.: Address: 7� L-1 Nml VRI Phone No.: JOBSlTE INFORMATION: (*Indicates required information) � *Name: 4a fV'Z *Address: -7o *Cross Street: i *Phone No.: t Permit No.: Tax-Map District: 1000 Section: Block: Lot: *BRIEF DESCRIPTION OF WORK(Please Print Clearly) l` (Please Circe All That Apply) *Is job ready for inspection: (O�V NO Rough In Final *Do you need a Temp Certificate: YES!® Temp Information (if needed) *Service Size: 1 Phase ' 3Phase 100 150 200 300 350 400 Other i *New Service: Re-connect Underground Number of Meters Change of Service Overhead Additional Information: PAYMENT DUE WITH APPLICATION 82-Request forinspecUon Form M ®r ®UT OLac,,AROPERTY RECORD- CAR® - OWNER STREET ' VILLAGE DISTRICT -S-U-6= LOT A-e- �7)nor F RMER bWNE enrc���f}Z O.rs. ' `N f� E' ACREAGE 0. 0-ka- ani �'Cr,, _Lx, .1 "! .4 /_ ,,� F (� :1` t �--.� ✓ s gid , fV 12 /- 7� 's S W TYPE OF BUILDING . 6�f-'G. -dr G'"as' ' `p,.��'� r ��4s I ,.�.A'i.•�L.s"t..�A wP...'C.r.. '�..dl..r'�r3°rt l �"-j / r�'�'xjr�f�!_ = RES /� SEAS. VL. I FARM COMM. "IND. I CB. I MISC. I , LAND IMP. TOTAL DATE REMARKSd 4- ,fr� .` a 192- -Z-0 93 7i" 00 6 � f r� . , BUND ND BELOW NO _ NEW NORMAL A O E n s= t ig1.0N91-L9e,Is---� 40 fie,(' 15 4 C- r Acr VAcre P , nlue D ;. � ; . D d-L( a l 3 � --Wo ��s 4o f'�`scaat 'N'6- T/rl able 1` dR Ti,(la$I�a 2 j�tJ d19 6 DYV, �✓ f� b-� r1�2 (-) r _....,. _ . -T�Ilable_ 3 v` /9-/� ,� '� - Jr.1�b® 30 C') �i 5- ,TO J4 Swampland Brushlan ,� ' _House Plot S ',57_ Z. 02202 4 - Taro ­77— V/V J.=Ct ;# M. Bldg. ="� ? _ BathC—: fi Foundation I A, deo �/� Extension >�' 5�11 Basement 1 ' `� r Floors o " :t Extension .-1 Ext. Walls '° ` t Interior Finish f ,a Extension Fire Place ��'-`' , Heat ft9 Porch �' Attic L) 16r Porch Rooms ]st Floor g� ,l 7 2 o � oo `Ja Patio Rooms 2nd Floor s ,?c Z.Z�et2 Garage • Driveway �1 O. B. r, i nEV•? �0_s LAND NiF JV1690,6000„ DrrrkERSI?N r�Q'00' 9'E , E Z'we FE, 2,7'E BULKHEA Only copies from the original of this survey marked with an 7,3'N original of the land surveyor's embossed seal sholl be conaldered to be valid true copies. Unauthorized alteration or addition to a survey map bearing a licensed load surveyor's sea( Is o violation of eeetion 7209, sub—divlalon 2, of the. Now York State Education Law. CerUflcotlon Indicated hereon stgnlfy that,this survey woe o prepared in a000rddnee with the oxisting Code of Proct)cs C.) for land Surveys cdbptad by the Now York State Association of Professlonol Land Surveyors. Sold oertifloatlone sholl run only to the person for wham the survey is prepared, and on w hls behalf to the title company, governmeptol agency and C.5 N O londing Institution listed hereon, and to the ossignees of the lending inotitutlon. Certifications are not tronsferoble to additional Institutions or subsequent owner. rj LAWN & TREES 2231 3613, Z 2 STY FRAME?, ' o AREA=34,028.34 SgF•t STpO� GAR, �? 0,7812 Acres P44 ST. CR E a U ASPHALT DRIVEWAY '� rr^^ pp LAWN & TREES pEGK C R h s' 4 mCHIMN. in #70le k6 t i STY FR: o� �, a 1 #ik SM•NT Po1 r Z CC LAWN �S CONC. � TREES MNT- FOUNDC& HELD R 0,6'S NO SIDEWALK CIINC, 10.2'E ASPHALT EDGf:' SO2040'40"N'r �,t126.68' D.[,L P HOLE, DRIVE T�.Li�;r NOTE. (WEST BRANCH) I. THE OFFSETS-OR DIMENS40NS SHOWN HEREON. FROM THE PROPERYY LINES TO THE STRUCTURES ARE tr TAKING FROM A SPECiFIC POINTS AND THEREFORE L"aBu "_--011 PTHEY ARE �L�p, �� r�� T ►'� A�' LINES OR TO GUIDEE THE ERECTION MONUMENT F FE CES, `70 D.CIZP HOLE DRIVE, ADDITIONAL STRUCTURES OR ANY OTHER � ��TT 1���� IMPROVEMENTS. OT1r1V OF SOUTHOLD, COUNTY OP SURI OLk 2. THISY ORAE POSE ONLY, NOT STAVE OF JV'EW Y6RK,, DIST. tOOO FOR3. EASEME $tib GUARANTEED. SEC- H5.00, BLOCK 72.00, LOT(S) 002.000 MjS(ONS 'PIT `�'Y 0, DATE 9MDE •f•C. 1. TiTL tVE 461 07-81.15 1. Wes-tcor Land Tltte Insurance Sl1R'1FYE MMIUS ad iEc' Corlpahy 2, Everbank 3. Thomas Randon and Mc:e BucaMe AREK SIJ �" sca►z, ` 4, Ambassador Abstract, LLC 2652 E,18th Street: 1' = 30` Prnoktyn, NY 11235 Job Noi Title No. AMB15-73052S TELT' (516) 946-908Q ORDS—RED SY surveynyc@r�srT,corT 1s-1`61 Ambassador Abstract, LLC Generated by REScheck-Web Software ` Compliance Certificate � L ! _ J FEB - 1 2016 �'�, i Project THE RANDON BUCAILLE RESIDENCE --- -- S Energy Code: 2010 New York Energy Conservation Location: Suffolk County, New York Construction Type: Single-family Project Type: Alteration Climate Zone: 4 (5750 HDD) Permit Date: Permit Number: Construction Site: Owner/Agent: Designer/Contractor: 70 DEEP HOLE DRIVE THOMAS RANDON&ALICE FRANK UELLENDAHL MATTITUCK, New York 11952 BUCAILLE ARCHITECT OWNERS Compliance6 Pastes Compliance 0.4%Better Than Code Maximum UA 236 Your UA 235 The%Better or Worse Than Code Index reflects how close to compliance the house Is based on code trade-off rules It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home Envelope Assemblies Gross Area Cavity Cont. Perimeter Ceiling: Cathedral 500 30.0 0.0 0.034 17 Ceiling: Flat or Scissor Truss 555 30.0 0.0 0.035 19 Wall:Wood Frame, 161n, o.c. 1,140 13.0 0.0 '0.082 77 Window:Wood Frame,2 Pane w/Low-E 101 0.300 30 Window:Wood Frame,Single Pane 17 0.290 5 Door:Glass 77 0.300 23 Wall:Wood Frame, 161n. o.c. 111 15.0 0.0 0.077 9 Floor:All-Wood Jolst/Truss over Uncond.Space 1,055 17.0 0.0 6.052 55 Compllance Statement: The proposed building design described here is consistent with the building plans,specifications,,and other calculations submitted with the permit application.The proposed building has been designed to meet the 2010 New York Energy Conservation Construction Code requirements in REScheck Version 5.5.0 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Name-Title Signature Date Project Title:THE RANDON BUCAILLE RESIDENCE Report date: 10/10/15 Data filename: Page 1 of 6 REScheck Software Version 5.5.0 Inspection Checklist Energy Code: 2010 New York Energy Conservation Construction Code Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section Plans Verified Field Verified # Pre-lrispection/Plan Review ` Value Value -Complies? Comments/Assumptions &Req.ID 103.2 :Construction drawings and ❑Complies ; [PRI]1 documentation sufficiently F ❑Does Not :demonstrates energy code :compliance for the building i` [-]Not Observable envelope. ONot Applicable ; 103.2, ;Construction drawings and ❑Complies ; 403.7 documentation sufficiently ❑Does Not [PR3]1 ;demonstrates energy code :compliance for lighting and ❑Not Observable ; mechanical systems.Systems '` ❑Not Applicable :serving multiple dwelling units ;must demonstrate compliance with the commercial code. I ; 403.6 Heating and cooling equipment Is; Heating: ; Heating: ;❑Complies ; [PR2]2 ;sized per ACCA Manual S based Btu/hr Btu/hr :❑Does Not ron loads per ACCA Manual J or ; Cooling: Cooling: :other approved methods. Btu/hr Btu/hr ❑Not Observable r ; ; ;❑Not Applicable ; Additional Comments/Assumptions: i .J 1 High Impact(Tier 1) 2- Medlum Impact(Tier 2) 3 Low Impact(Tier 3) Project Title:THE RANDON BUCAILLE RESIDENCE Report date: ;10/10/15 Data filename: Page 2 of 6 I� Section #. Foundation Inspection. Complies? Comments/Assumptions &Req.ID - . 303.2.1 2 Exposed foundation Insulation ;❑Complies [FO11]2 'protection. ❑Does Not tJ { ;❑Not Observable ;❑NotApplicabie 403.8 ySnow melt controls. ;❑Complies [FO12]2 or ;❑Does Not Ql ;❑Not Observable; i :❑Not Applicable Additional Comments/Assumptions: I i { i 1 I I 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) I Project Title:THE RANDOM BUCAILLE RESIDENCE Report date: 10/10/15 Data filename: Page 3 of 6 I i i i Section, Plans Verified Field Verified # Framing/Rough-In Inspection Value " Value Complies? , Comments/Assumptions & Req.ID 402.4.4 ;Fenestration that Is not site built ❑Complies ; [FR20]1 :Is listed and labeled as meeting ❑Does Not ;AAMA/WDMA/CSA 101/I.S.2/A440 109 :or has Infiltration rates per NFRC ❑Not Observable ; :400 that do not exceed code ; ❑Not Applicable limits. 402.4.5 ;IC-rated recessed lighting fixtures ❑Complles ; [FR16]2 +sealed at housingrnterior finish y ❑Does Not Sand labeled to indicate&It;= 2.0 ❑Not Observable �cfm leakage at 75 Pa. ❑Not Applicable ; 403.2.2 ;All joints and seams of air ducts, ❑Complies ; [FR13]1 pair handlers,filter boxes,and ❑Does Not building cavities used as return ; :ducts Observable ducts are sealed. IE]Not Applicable ; 403.2.3 ;Building cavities are not used as ti ❑Complles ; [FR15]3 :ducts or plenums. []Does Not U []Not Observable ; ❑Not Applicable 403.3 y HVAC piping conveying fluids R- ; R- ;❑Complles ; [FR17]2 :above 105 4F or chilled fluids ❑Does Not below 55 QF are Insulated to R-3. ;❑Not Observable ❑Not Applicable 403.4 Circulating service hot water ; R- ; R- ;❑Complles ; [FR18]2 pipes are Insulated to R-2. ;❑Does Not V UNot Observable ❑Not Applicable 403.5 tiAutomatic or gravity dampers are ❑Complies [FR19]2 installed on all outdoor air ❑Does Not SIntakes and exhausts. r ❑Not Observable , IE]NotAppllcable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title:THE RANDON BUCAILLE RESIDENCE Report date: 10/10/15 Data filename: Page 4 of 6 i I Section # Insulation Inspection Complies? Comments/Assumptions &Req.ID II; 303.1 All Installed Insulation labeled or ;❑Complies ; [IN13]2 installed R-values provided. ;❑Does Not ;❑Not Observable ❑Not Applicable Additional Comments/Assumptions: I I 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) 4 Project Title:THE RANDON BUCAILLE RESIDENCE Report date: 10/10/15 Data filename: Page 5 of 6 I I section. ' '� ' Plans Verified Field Verified # Final Inspection Provisions Complies? Comments/Assumptions &Req.ID Value Value 402.4.2, ;Building envelope tightness ; ACH 50= ; ACH 50 = ;[]Complies ; 402.4.2.1 :verifled by blower door test result: PDoes Not [F117]1 :of&lt;7 ACH at 50 Pa.This (9 :requirement may instead be met ;❑Not Observable ; :via visual Inspection,in which : ; ;❑Not Applicable ; :case verification may need to ;occur during Insulation ; :Inspection. 403.2.2 :Duct tightness via post- cfm cfm ;❑Complies ; [FI4]1 :construction with maximum : ❑Does Not U :leakage of 8 cfm to outdoors,or :12 cfm across systems.For UNot Observable :rough-In tests,verification may : ; ;❑Not Applicable ; :need to occur during Framing ;Inspection,with maximum :leakage of 6 cfm across systems ;and 4 cfm without air handler, ; 403.1.1 ;;Programmable thermostats ❑Complies ; [FI9]2 r Installed on forced air furnaces, ❑Does Not ❑Not Observable ❑Not Applicable 403.1.2 +Heat pump thermostat Installed ❑Complies ' [1`I10]2 ,on heat pumps. ❑Does Not v ❑Not Observable ; } ❑Not Applicable 403.4 ;Circulating service hot water ❑Compiles ; [FI11]2 systems have automatic or : E]Does Not v ,accessible manual controls. : ❑Not Observable ' IONot Applicable 401,3Compliance certificate posted. ❑Complies ; [FI7]2 r []Does Not u ❑Not Observable IE]Not Applicable 303.3 ;Manufacturer manuals for ❑Compiles ; [F118]3 ;mechanical and water heating ❑Does Not ' u :equipment have been provided. : : ❑Not Observable ; ❑Not Applicable Additional Comments/Assumptions: i II 1 High Impact(Tier 1) 2 lMedlum Impact(Tier 2) 3 Low Impact(Tier 3) Project Title:THE RANDON BUCAILLE RESIDENCE Report date: 10%10/15 Data filename: Page 6 of 6 2010 New York +. Energy Conservation Construction Code Energy Efficiency Certificate Insulation . Above-Grade Wall 13.00 Below-Grade Wall 0.00 Floor 17.00 Ceiling/Roof 30.00 Ductwork (unconditioned spaces): Glass&Door Rating U-Factor SHGC Window 0.30 Door 0.30,Heating & j Cooling Heating System: Cooling System: Water Heater: Name: Date: Comments i I I I - I i I { 1 ❑ - - — — — — —ET-- — EF- — — — — — — ❑ ALTERATIONS Oq r I 1 N o NXIO1117I� FEB - 1 2016 - L XZ w I o o COVERED � N N I PATIO w 16,_0" » RESIDENCE 4-2 6 -6 4 -3 10 -6» ilk MATTITUCK, NY I w 70 DEEP HOLE DRIVE J Z O 0 ARCHITECT #kMA FRANK O.BOXD316AHL P.O.BOX 316C., GREENPORT, NY 11944 BATH R . TEL: 631-477 8624 OWNERS I THOMAS RANDON & ALICE BLICAILLE 3 154 BROADWAY, APT 4 Y $ NY 11211 30"X80" - 24 CD P STORAGE ROOM fire—rated N r32180" +C HALLWAY MECH. RM. GARAGE - CLG.HGT, = 7'-2" N \ %;• — — — — — — — *— — — — — — — 5/8" GYP.BD. ON o GARAGE WALLS AND CEILING s z a CLOSET � zz o �� m PANTRY w ---------------------- w 32"X80" El N o fire-rated o Z DATE: 01/24/2016 i UP 12" DEEP CABINETS N SCALE: 1/4" = 1'-0° =o 3¢ EXISTING A BASEMENT PLAN ZS Ln N Z „ , „ , „ a DWG. NAME 6 -2 7 -11 9 -10 Co A-2.1 26'-9„ ®¢ DWG, NO �,,ff ALTERATIONS LEGEND w Z AIN A I N EXISTING WALL 0 PROPOSED WALL P 0 x WOOD DECK FEB - 1 2016 C- - - - C WALL REMOVED o J w 44'- w 18'-10 1/2" 8'-10" 5'_O" 10,_2„ RESIDENCE 15-9 a R.O. S-01) 3 -O -�-- � NY oDEEP HOLE�DRIVE ®FWG16068-4 z z 0 �- — -� HEADER: 1.75"X11-7/8" LUL I I I DW I m ARCHITECT FRANK UELLENDAHL L_ — J P.O.BOX 316 w GREENPORT, NY 11944 WOODBURNING FIREPLACE r o TEL: 631-477 8624 SUPERIOR 42" WCT 3000 C-0 N I I 001 o OWNERS cn r l I I (9) z u KITCHEN N BEDROOM 1 THOMAS UO & ALICE BCAILLCAILLE O o 0 3 154 BROADWAY, APT 4 21- 1 1 1 1 �_ 0 m CANDRAL CEILINt Z BROOKLYN NY 11211 1 I 11 x Cr) 00rl 1 1 `�' TEL: 917-293-3524 1 1 LIVING ROOM 1 1 � w I I 1 1 o `5���u `�' ; o � I I CATHEDRAL CEILING I I w o j L — I - -� J AZ X N 10'-4 1/2" I I HALLWAY �� t -�N(WL3)1_75"X14" LVL RIDQ� ' EAM _ _ CLG. HGT: 8'-O" — — — — — — C7 N V� z OF CD 7,-213 1 7,-21) 1 71-21 o PPORT RIDGE BEAMcn n 28'41W/ (3) 1.75"X14" LUL COLLAR BEAM ^ o AND TIE INTO 2 2x10 RAFTERS o p cn II II I � 11 BEDROOM 3 BEDROOM 2 II II � oN � N � pO O LJ LJ Jo •^ 0o W DATE: 01/24/2016 COVERED PORCH N SCALE: 1/4" = 1'-0" CONCRETE W.I.CLOSET 3¢ PROPOSED ❑ FLOOR PLAN ❑ ❑ ❑ ❑ N Z DWG. NAME c5 PROPOSED FLOOR PLAN ©¢ DWG. NO A-3 SCALE; 1/4" = l'-O" DESIGN CRITERIA: ��� � ALT, ATIONS W USE I NLA _ � AND K TI GROUND SNOW LOAD - 45 PSF. t/ L� ,fin a D � ITI 6 T TIFICATj ` LIVING AREAS AND DECKS - 40 PSF, DATE: N SLEEPING AREA - 30 PSF. F C C PAN CY W WIND SPEED - 120 MPH FE " ' Y a Z SEISMIC DESIGN CATEGORY - B RI I i n,,,. F Ttv1FNT A T w WEATHERING - SEVERE FROST LINE DEPTH - 36" TERMITE - MODERATE TO HEAVY DECAY - SLIGHT ICE SHIELD UNDERLAYMENT REQUIRED - YES W DESIGN IN ACCORDANCE WITH AMERICAN FOREST RESI®EI�iCE PRODUCTS WOOD FRAME CONSTRUCTION MANUAL vRTC C. MUST MATTITUCK, NY FOR 1&2- FAMILY HOUSE - PRESCRIPTIVE DESIGN METHOD A OUA 1 10 DEEP HOLE DRIVE WINDBORNE U THE C DES NEW o DEBRIS PROTECTION SCHEDULE p po y W W Y W Y - ._ -- - _ = � FRANK UELLENDAHL OF MIN 7/16 INCH WITH 2-1/2 #6 WD SCREWS, P.O.BOX 316ARCHITECT PRECUT WOOD STRUCTURAL PANELS NTH A THICKNESS SPACING: 12 INCHES ARE TO BE PROVIDED TO COVER GREENPORT, NY 11944 THE GLAZED OPENINGS OF THE PROPOSED SLIDER - TEL: 631-477 8624 PROPOSED WEST ELEVATION _ ��,;;pt 2 VJI;R ALL CODES OF OWNERS WINDOW SCHEDULE ' / NEW YORK STA, � � T��`� CODES 9 THOMAS RANDON 1/ AS REQUIRED "� `"� ' � -ni=p OF 3 &ALICE BUCNLLE 154 BROADWAY, APT 4 "r'A BROOKLYN, NY 11211 PROPOSED SLIDING DOOR ARE ANDERSEN PRODUCTS 400 SERIES. $ D TEL: 917-293-3524 GLASS TO BE NIGH PERFORMANCE LOW-E GLASS - v EXTERIOR SLIDING SCREEN TO BE PROVIDED FOR DOOR ;S HARDWARE - METRO COLLECTION: ANVERS, SATIN NICKEL FINISH - ' R R INTERIOR FINISH: PRE-FINISHED WHITE Mark Size Description Quantity 9 A FWG 16080-4 GLIDING DOOR 1 ' o DRAWING SCHEDULE \� A-1 TITLE SHEET - DESIGN CRITERIA - ELEVATION A-2 EXISTING FLOOR PLAN A-3 PROPOSED FLOOR PLAN Z A-4 CROSS SECTION A-A A-5 NAILING SCHEDULE, FRAMING NOTES • W W W •Y W W .Y W __-.fi •.l.'.%= _ m� GENERAL NOTES W W W W W W W W _ _ _"_ -_ _ - _.T.," _ - _ _ all EXISTING WEST ELEVATION N 1. ALL WORK MATERIAL, AND EQUIPMENT SHALL BE IN o ACCORDANCE WITH THE NEW YORK STATE UNIFORM BUILDING CODE, AND THE NEW YORK STATE ENERGY INTERIOR ALTERATIONS TOA 3—BEDROOM DWELLING: o CONSERVATION CODE, AND LOCAL AUTHORITIES. REMOVE 8 FT CEILING IN LIVING / DINING KITCHEN AREA TO CREATE CATHEDRAL CEILING W DATE: 10/14/2015 2. ALL LUMBER SHALL BE GRADE STAMPED DoucfAs FIR- UPGRADE INSULATION IN THIS AREA AND R PLACE 8FT SLIDER WITH 16FT SLIDER SCALE: N.T.S. LARCH STRUCTURAL GRADE #2 OR BETTER. Y TITLE SHEET 3. CONTRACTOR SHALL OBTAIN ALL PERMITS AND BUILDING PERMIT APPLICATION o DESIGN CRITERIA INSURANCE NECESSARY TO PROTECT THE ENGINEER `-� GENERAL NOTES AND OWNER. N 4. THIS DRAWING IS AN INSTRUMENT PREPARED TO OCTOBER 14, 2015 S2 52 r DWG. NAME FACILITATE CONSTRUCTION AND SHALL NOT BE FRANK W. UELLENDAHL, ARCHITECT P.O. BOX 316 GREENPORT, NEW YORK 11944 A-1 CONSTRUED AS A CONTRACT BETWEEN BUILDER AND ©¢ DWG. NO OWNER. ALT RATIONS z AN o O K - � A N J � 0 WOOD DECK a Z U W J f!7 Z _ _ N 22'-o„ a ; w -44'- w 18'-10 1/2" 8'-10" 5'-0" 10'-2" REII®ENCE 8'-0" �- � '� 3 -0 3'-0" 3 _0 I NY �� 0 DEEP HOLE DRIVE z 0 J O ° ARCHITECT o � FRANK UELLENDAHL P.O.BOX 316 w GREENPORT, NY 11944 D �E TEL: 631-477 8624 DINING AREA KITCHEN 00 BEDROOM 1 o OWNERS LINOLEUM THOMAS RANDON O O & ALICE BUCAILLE Y 154 BROADWAY, APT 4 BROOKLYN, NY 11211 w TEL: 917-293-3524 LIVING ROOM a CLG, HGT; 8'-0" N w HALLWAY — _ — - Lo � o N 1 a c a a � � z o m 0 BEDROOM 3 BEDROOM 2 o N 0 J� o W DATE: 10/14/2015 COVERED PORCH 4 SCALE: 1/4" = 1'-0° CONCRETE W,I,CLOSET Y 3¢ EXISTING ❑ FLOOR PLAN ❑ ❑ ❑ ❑ N(n 26'-9" DWG. NAME 0 EXISTING FLOOR PLAN © DWG, NO A-2 SCALE: 1/4 = 1 -0 ALTERATIONS LEGEND o Z 10N EXISTING WALL WOOD DECK PROPOSED WALL W 0 I- - - - - WALL REMOVED o Z o N N i w ' 44'_ „ w 18'-10 1/2„ 5'_D,1 101_211 RESIDENCE 3 MATTITUCK, NY 15'-9 /" R.O. ' 4 3 -o ��—� 3 -� { - 70 DEEP HOLE DRIVE AQ FWG16068-4 J O --- m ARCHITECT HEADER: 2 1.75"X 11-7 8" LVL r ( ) / i I DW I . o — J FRANK P D O .BOX316 C j � zI I GREENPORT, NY 11944 0 w TEL; 631-477 8624 `2N � I Q Q LJ o o OWNERS cn THOMAS RANDON r� r� o 1 1 I I KITCHEN N 00 BEDROOM 1 & ALICE BUCAILLE CAT�I ¢ m DRAL CEILING ° Y 154 BROADWAY, APT 4 _ I I I I BROOKLYN, NY 11211 x c 03 n S I I I I I TEL; 911-293-3524 1 1 LIVING ROOM I I I I I a A w o , I I CATHEDRAL CEILING I I I - I I - t NII ,) I '- - - HTW-4 1/2" 11 -1 I HALLWAY, _ _ (3) 2x4 POST NEWA3L1.75 X14 LVL R DGE BEAM _ _ _ t _ _ _ _ _ _ CLG. HGT: 8 -0 - - _ _ _ _ cn o J N 71 -2„ I I 7,-2„ I I 71 _21 J j v n I I PPORT RIDGE BEAM w/ (3) 1.75"X14" LUL COLLAR BEAM o AND TIE INTO 2 2x10 RAFTERS K' c U m II II I � II BEDROOM 3 BEDROOM 2 II II LJ LJ A COVERED PORCH � o W DATE; 10/14/2015 � CONCRETE W.LCLOSET SCALE: i/4" = 1'-0° Y PROPOSED Elngm FLOOR PLAN O N DWG. NAME 0 PROPOSED FLOOR PLAN ©¢ DWG. NO A-3 SCALE: 1/4" = 1 -0 ALT RATIONS NOTE; o Z A AD EON IN AREA OF CATHEDRAL CEILING - O � 0 EXT'G R-17 BATT INSULATION TO BE X UPGRADED TO R-30 ROCKWOOL INSULATION CONT. RIDGE VENT Z NEW KNEE WALLS TO BE 2X6 STUDS EXT'G 2X8 RIDGE BEAM TO REMAIN WITH R-23 ROCKWOOL INSULATION NEW (3) 1.75x14" LVL RIDGE BEAM REMOVE EXT'G 2X4 COLLAR TIES (16" O.C.) SISTER NEW 2X10 R.R. TO EXT'G 2X6 R.R. @ 16 O.C. w/ R-30 STONEWOOL INSULATION — — — — EXT'G 2X4 GABLE WALL TO BE INSULATED w/ R-15 STONEWOOL RESIDENCE 2 MATTITUCK, NY 1/2" GYPSUM BOARD NEW (2) 2X8 COLLAR BEAMS @ 86 O.C. N 10 DEEP HOLE DRIVE EXT'G 2X6 R.R. @ 16" .C. o Q \ d x m ARCHITECT ATTIC 2X6 STUD WALL w/ R-23 STONEWOOL INSULATION EXT'G (2) 2X4 TOP PLATE FRANK UELLENDAHL - - — — — - - — — — — — — — — — S2 P.O,BOX316 — — — — — — — — — — — w GREENPORT, NY 11944 —�- - �� — iE TEL: 631-477 8624 REMOVE EXT G 2X8 C.J. @ 16 O.C. HURRICANE CLIPS EACH RAFTER (2) 1.75"x11-7/8" LVL HEADER OWNERS THOMAS RANDON & ALICE BUCAILLE o Y 154 BROADWAY, APT 4 o - SK N, NY 11211 TEL: 917 1 -2 33524 0 EXT'G WOOD DECK 0o LE FRONT PORCH LIVING ROOM ^z4N 0 � / Q IE R / C2 BASEMENT PATIO z 0 IIA W DATE: 10/14/2015 SCALE: N.T.S. o CROSS SECTION DWG. NAME CROSS SECTION og A-4 W ALTERATIONS • - FRAMING NOTES NAILING SCHEDULE TABLE 3.1 — wFcM = Z A CK lid o A ON 1. ALL FRAMING LUMBER SHALL BE GRADE STAMPED Joint Description Nail Sizes Nail Spacing O DOUGLAS FIR-LARCH STRUCTURAL GRADE No. 2 OR ROOF FRAMING J Q BETTER. X Rafter to Top Plate (Toe-�Toi'e�)nailed) a - all Height: 10 ft Spacing 16" O.C. (Table 3.3A) 4 - 8d per rafter 2. ALL SHEATHING TO BE APA RATED, EXPOSURE 1, 5/8" Ceiling Joist to Top rki n/a per joistMIN. THICKNESS OR AS NOTED. Ceiling Joist to Parallel Rter (Fa e-nailed n/a each lap Ceiling Joist Laps ovQr Partitions Face-nal ed) n/a each lap 3. ALL SUBFLOORING TO BE APA RATED STURD-I-FLOOR, Collar Tie to Rafter,(Face-nal ed) nn 'a per tie N EXPOSURE 1 3/4" MIN. THICKNESS. ALL EDGES OF Blocking to Rafter ( o -nailed 2 - 8d each end , PLYWOOD T0�BE SET ON SOLID BLOCKING. GLUE AND En Rim Board to Rafter End-nal ed) 2 - 16d each end a , NAIL PLYWOOD SUBFLOOR TO FLOOR JOISTS. WALL FRAMING RESIDENCE 4. ALL HEADERS 6'-0" AND OVER SHALL BE SUPPORTED Top Plate to Top Plate (Fac -nailed) 2 - 16d 1 per foot RESIl®ENCE WITH DOUBLE UPRIGHTS, 9'-0" AND OVER WITH Top Plates at ntersection Face-nailed) 4 - 16d joints-each side MATTITUCK, NY TRIPLE UPRIGHTS. ALL HEADERS SHALL BE A Stud to Stud (!Face-nailed 2 - 16d „ 24 o.c. MINIMUM OF 2-2X8 OR AS SHOWN ON DRAWING. Header to Header (Face-nailed) 16d 16 o.c. along edges 70 DEEP HOLE DRIVE 5. SOLID BLOCKING SHALL BE PROVIDED FOR ALL JOISTS Top or Bottom Plate to Stud (End-nailed) 2 - 16d per 2x4 stud o AND FLOOR BEAMS AS PER N.Y.S. CODE OR AS NOTED 2 - 16d per 2x6 stud Q 2 - 16d per 2x8 stud 8'-0" O.C. MIN. PROVIDE 2" SPACE FOR AIR o CIRCULATION IN ROOFS. Bottom Plate to Floor Joist,Bandjoist,Endjoist or Blocking (Face-nailed) 2 - 16d 1'2 per foot m ARCHITECT 6. DOUBLE FRAMING AROUND ALL OPENINGS ( skylights, FLOOR FRAMING FRANK F BOXD316 stairs etc. ) OR AS NOTED ON DRAWINGS, GREENPORT, NY 11944 Joist to Sill Top Plate or irder (Toe-nailed) 4 - 8d per joist TEL: 631-477 8624 7. DOUBLE UP FRAMING UNDER ALL POSTS AND PARALLEL Bndgin to Joist Toe-nailed 2 - 8d each end PARTITIONS OR AS NOTED ON DRAWINGS. Blocking to Joist Toe-Wade 2 - 8d each end Blocking to Sill or Top Plate ( Toe-nailed) 3 - 16d each block o OWNERS 8. ALL FLUSH WOOD CONNECTIONS SHALL BE FASTENED Ledger Strip to Beam (Face-nailed) 3 - 16d each joist Jager Ledger to earn (Toe-nailed) 3 - 8d per joist THOMAS RANDON WITH RATED GALVANIZED METAL CONNECTORS BY Band Joist to Joist End-nailed) 3 - 16d per foist & ALICE BUCAILLE "TECO" OR APPROVED EQUAL. Band Joist to Sill or Top Plate (Toe-nailed) 2 - 16d 1 per foot Y154 BROADWAY, APT 4 9. NAILING SCHEDULE SHALL BE AS PER THE N.Y.S. ROOF SHEATHING E! BROOKLYN, NY 11211 BUILDING CODE AS A MINIMUM, ALL 2X6 STUDS TEL: -293-3524 SHALL RECEIVE 5-10D NAILS AT SILL AND PLATE. Structural Panels 8d 4" ox.„perimeter zone ALL EXTERIOR NAILS SHALL BE GALVANIZED. other 6 ox, edges of panel, 12 o.c. interior 10. PLYWOOD SHEATHING TO BE NAILED WITH 8 d @ 4 of panel Diagonal„Boar, Sheathing „ y o.c. EXTERIOR EDGES AND 6 d @ 12" o.c. INTERMEDIATE. 1" x 10, orlwider8 3 - 8d per support 11. ALL INTERIOR AND EXTERIOR FINISHES, FLASHING CEILING SHEATHING p .� AND WATERPROOFING SHALL BE BY ARCHITECT. Gypsum Wallboard 5d 7" edge / 10" field 12. ALL ROOF RAFTERS SHALL BE ATTACHED TO THE PLATE N WALL SHEATHING AND STUD WITH GALVANIZED HURRICANE TYPE CONNECTORS BY "TECO" OR APPROVED EQUAL. FOR Structural Panels 8d 6" edge / 12" field TIMBER PILE FOUNDATIONS, PROVIDE HURRICANE Fiberboard Panels CLIPS AT ALL PERIMETER JOIST TO GIRDER 7 / 16" 6d 3" edge / 6" field CONNECTIONS. 25 / 32" 8d 3" edge / 6" field 13. ALL PRE-ENGINEERED LUMBER SHALL BE GEORGIA PACIFIC GPI SERIES WOOD-I-BEAMS AND LVL Gypsum Wallboard 5d 7" edge / 10" field PRODUCTS OR EQUAL. ALL JOISTS, GIRDERS AND Hardboard 8d 6" edge / 12" field g HEADERS SHALL HAVE BEARING STIFFENERS INSTALLED Particleboard Panels 8d 6" edge / 12" field AS PER MANUFACTURERS RECOMMENDATIONS. WEB Diagonal Board Sheathing N STIFFENERS SHALL BE REQUIRED AT ALL LOAD AND1" z 6" or 1" x 8" 2 - 8d per support o BEARING POINTS AT A MINIMUM. 1" x 10" or wider 3 - 8d per support o HANDLING, STORAGE, AND ERECTION OF COMPONENTS SHALL BE AS PER MANUFACTURERS FLOOR SHEATHING RECOMMENDATIONS. Structural Panels a W DATE; 10/14/2015 14. ALL MULTIPLE LVL PRODUCTS TO HAVE 2 ROWS OF 1/2 DIA. 1" or less 8d 6"„ edge / 1?" field SCALE: N.T.S. GALVANIZED MACHINE BOLTS 0 12" O.C.. greater than 1 10d 6 edge / 6 field o Diagonal Board Sheathing 2 - 8d per support Y FRAMING NOTES t2 12' 12' j;;7 1 x 10 or wider 3 - 8d per support Nailing Schedule o� OR: TRUSSLOK CONNECTORS BY 'FastenMaster' ® 16" O.C. 1"Nailing requirements are based on wall sheathing nailed 6" on-center at the panel edge. If wall sheathing is nailed DWG. NAME 3 on-center at the panel edge to obtain higher shear capacities nailing requirements Tor structural members shall be doubled , or alternate connectors , such as shear plates , shall be used to maintain the load path. o When wall sheath)q�is continuous over connected members , the tabulated number of nails shall be permitted to DWG, NO A-5 t6' t • be reduced to 1 - t�id nail per foot.