Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
40232-Z
Town of Southold 2/24/2016 P.O.Box 1179 . 53095 Main Rd y�o �p4 Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 38114 Date: 2/24/2016 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 6565 Bridge Ln, Cutchogue SCTM#: 473889 Sec/Block/Lot: 84.-1-6.9 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 10/29/2015 pursuant to which Building Permit No. 40232 dated 10/29/2015 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: ROOF MOUNTED SOLAR PANELS TO AN EXISTING ONE FAMILY DWELLING AS APPLIED FOR The certificate is issued to Secaida,Juan of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 40232 01-26-2016 PLUMBERS CERTIFICATION DATED ' Authorized Signature ,,, SAF o� ld, TOWN OF SOUTHOLD � eoay BUILDING DEPARTMENT TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 40232 Date: 10/29/2015 Permission is hereby granted to: Secaida, Juan 6565 Bridge Ln Cutchogue, NY 11935 To: installation of roof-mounted solar panels as applied for. At premises located at: ' 6565 Bridge Ln, Cutchogue SCTM # 473889 Sec/Block/Lot# 84.-1-6.9 Pursuant to application dated 10/29/2015 and approved by the Building Inspector. To expire on 4/29/2017. Fees: SOLAR PANELS $50.00 CO -ALTERATION TO DWELLING $50.00 TRIC $100.00 • T. al: $200.00 411 Building Inspector Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings,property lines,streets,and unusual natural or topographic features. 2. Final Approval from Health Dept.of water supply and sewerage-disposal (S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1%lead. 5. Commercial building, industrial building,multiple residences and similar buildings and installations,a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings(prior to April 9, 1957)non-conforming uses,or buildings and"pre-existing"land uses: 1. Accurate survey of property showing all property lines,streets,building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00,Alterations to dwelling$50.00. Swimming pool$50.00.Accessory building$50.00.Additions to accessory building$50.00. Businesses$50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy-$.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy-Residential$15.00,Commercial$15.00 Date. - -/0/a // _ New Construction: Old or Pre-existing Building: - (check one) Location of Property: 5 •- .k`/ ll 3� I louse No. Street (� Hamlet Owner or Owners of Property: __. c1 GLS_. �. 0_Gt / GL-_-• - Suffolk County Tax Map No 1000.Section ---------__ _ _ Block`__ __ _ _ Lot Subdivision _ _____-�. _._ _ Filed Map. _ ____- _ _ Lot: Permit No. Date of Permit. /4.f _ I Iealth Dept.Approval: _ Underwriters Approval:__- -_ Planning Board Approval: _______ Request for: Temporary Certificate _ _. _ Final Certificate:___ (check one) Fee Submitted:$ �U p icant Signature I,��, .ice 1'•c•••101f SO!/Tyelo Town Hall Annex �� . Telephone(631)765-1802 54375 Main Road i Jig * Z Fax(631)765-9502 P.O.Box 1179 % G ki Southold,NY 11971-0959 L`'`r0, ... ?�11 roger.richert(a�town.southold.ny.us yi, =.c®UruOlc:of e•... %.' BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION Issued To: Secaida Address: 6565 Bridge Lane City: Cutchogue St: New York Zip: 11935 Building Permit#: 40232 Section: 84 Block: 1 Lot: 6.9 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: Solar City License No: 51331-ME SITE DETAILS Office Use Only Residential X Indoor Basement Service Only Commencal Outdoor X 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures I HID Fixtures Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel NC Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel NC Blower Range Recpt Fluorescent Fixture Pumps Transformer Appliances Dryer Recpt Emergency Fixtures Time Clocks Disconnect Switches Twist Lock Exit Fixtures TVSS Other Equipment: 12.22 KW Roof Mounted Photovoltaic System to Include, 47- Trina TSM 260 Panels 1-6000 W,and 1-4200 W Inverters-Zigbee. Notes: IF Inspector Signature: , Date: January 26, 2016 ►� Electrical 81 Compliance Form xls Version#53.6 P • 1 SolarCity Project/Job# 119934 RE: Installation Approval Letter 1i I1 fig" Project: Secaida ResidenceIli7 r' 6565 Bridge Ln i j f'fff Cutchogue, NY 11935 FEB 2 3 2016 /, / Date of Review 2/11/2016 I """ 1 Permit# 40232 — , --_ __ Date of Install 1/13/2016 AHJ Southold Town SC Office Long Island To Whom It May Concern, On the above referenced project,the roof structural framing has been reviewed for additional loading due to the installation of the solar PV addition to the roof.The structural review, including the plans and calculations only apply to the section of roof that is directly supporting the solar PV system and its supporting elements. The capacity of the structural roof framing directly supporting the additional gravity loading due to the solar panel supports and modules had been reviewed and determined to be in accordance with the requirements of the 2010 Residential Code of NY State. I certify that the work has been completed in accordance of the provisions of the approved permits of the applicable code. Should you have any further questions or requirements pertaining to this project, please do not hesitate to contact me. OF NEW Paul Zacher, P.E. r'p � Professional Engineer *��` K. Zig C T: 916.961.3960 x101 1 -'4(211 ,yF email: paul@pzse.com r' i7 ' ; � wl .=-- = O 91365x,1.8<t AROFESSION ' 3055 Clearview Way San Mateo,CA 94402 r(650)638-1028 (888)SOL-CITY F(650)638-1029 solarcity.com AZ ROC 243771 CA CSLB 888104,00 BC 5041 CT HID 0632778 DC FITC r 1101480,DC HIS 71101488,HI CT-29770 MA HIC 1611572,MD MHIC 178048 NJ 13VH05160600, OR CCB 180493,PA 077343,TX TOL R 27008 WA GCL SOLARC'9W07 17 2013 SoknrC4y All rintlL rLserved EILLD 3I�TS C QNE 1 FOI�r DATA ,,, .. , - . __,_, sa.3 1 FOTrm,flON(1ST) FOUNDA,TION(arm) • . / , al cm, . �P F c4 *.3 , )g W� ROUGH FR. I Q& mem "" H PLUMBING - -- -- i (1) . . , IIIIII g-- . opm . . ' . ow - ,, ti, . ow . m H INSULATION PEA N.Y. • STATE ENERGY CODD 1' • FINAL MIMI . • _ A ). i Ti DNS Gc own c.� • ' CO rPg • -- • . . . _ • • ( 2 . . . - . _ , , , , \ . 0 , . _ . . .) z . . ... . ...._ „. , ," ,. _.... , ._ . . N ... . _ . _..... . 4., 1 1J v1LL111v UL'I P11.11VIL`1\1 Do you have or need the following,befoie.applying? TOWN HALL Board of Health 'SOUTHOLD,NY 11971 4 sets of Building Plans TEL: (631) 765-1802 - Planning Board approval FAX: (631) 765-9502Survey SoutholdTown.NorthForlc.net PERMIT NO. 0-2,t':31— Check 1— Check Septic Form N.Y.S.D.E.C. Trustees C.O. Application Flood Permit Examined 0 ,20 Single&Separate Storm-Water Assessment Form Z /-3° Contact: Ca. /"v Approved ,20 Mail to:_Po /Oy et*? Disapproved a/c ?c3 //�& /L�,,,[•l sv� C hone: Expiration_ 20 41," 7f---c/ �_. i,, I, 1117 Build ig Inspector 1i rH IJ 1'I I. (l1 AP LI ATION FOR BUILDING PERMIT OCT 2 8 2015 Date / bb CO , 20 I L INSTRUCTIONS DG DEN I -Tyfo ec cfw-i-LI lLI) a. This-application-MUSS-T-be-eempietefy'filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans, accurate plot plan to scale. Fee according to schedule. b. Plot plan showing location of lot and of buildings on premises, relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit ;hall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector ssues a Certificate of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of ssuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the )roperty have been enacted in the interim, the Building Inspector may authorize, in writing,the extension of the permit for an ddition six months.Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Wilding Zone Ordinance of the Town of Southold, Suffolk County,New York, and other applicable Laws, Ordinances or egulations,for the construction of buildings,additions,or alterations or for removal or demolition as herein described.'The pplicant agrees to comply with all applicable laws, ordinances, building code, housing code, and regulations,and to admit uthorized inspectors on premises and in building for necessary inspections. (Si a tire of applicant or name, if a cor ration) V3 A/ie P/61 ,Svi c (Mailing address of applicant) 111Y- 7-6Pr ate whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder ()/ ame of owner of premises C Ail £0 (As on the tax roll or latest deed) applicant is a corporation, signature of duly authorized officer (Name.and title of corporate officer) Lilders License No. 5 a0 5 3- `-4 .umbers License No. e.ctricians License No: S/33 1/V6 her Trade's License No. C' U,7) - L-00 V i V3 Location of land on which proposed work will be done: 25Co5 /3ric/ /Gr:e / r'' rr 09ve- Ary // House Number-�:• C Street v Hamlet County Tax Map No 1000 „Section OcfBlock Lot bq Subdivision - filed Map No. Lot 2. State existing use and occupancy of premises an intended use and occupancy of proposed construction: a. Existing use and occupancy cid, /r 7i -Q b. Intended use and occupancy 3. Nature of work (check which applicable): New Building Addition Alteration Repair Removal Demolition Other Work 1{0 _A),j74- fo/ar' I 0 3 (Description) 4. Estimated Cost " c Fee (To be paid on filing this application) 5. If dwelling, number of dwelling units Number of dwelling units on each floor If garage, number of cars 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of existing structures, if any: Front Rear Depth Height Number of Stories • „ Dimensions of same structure with alterations or additions: Front Rear Depth Height Number of Stories 8. Dimensions of entire new construction: Front Rear Depth Height Number of Stories 9. Size of lot: Front Rear Depth 10. Date of Purchase Name of Former Owner 11. Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law, ordinance or regulation? YES NO 13. Will lot be re-graded? YES NO Will excess fill be removed from premises? YES NO 14. Names of Owner of premises 0 a n Sec a I cL& Address (PC-69C&&i dst `6' Phone No.&3/-R-b 6-71 3 Name of Architect Address Phone No Name of Contractors /a/ Address*?3 Re/z/f'/C,l Phone No.b3/- d-S"-a/o 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO * IF YES, SOUTHOLD TOWN TRUSTEES & D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal.wetland? * YES NO * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey, to scale, with accurate foundation plan and distances to property Iines. 17. If elevation at any point on property is at 10 feet or below, must provide topograpliidal•data oii 'i Vey: 18. Are there any covenants and restrictions with respect to this property? * YES NO * IF YES, PROVIDE A COPY. STATE OF NEW YORK) SS: COUNTY OF ) being-duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)He is the _d J / C/ - - - (Contractor, gent, Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge ane t,Gl e ,N ATALIE PERA performed in the manner set forth in the application filed therewith. NOTARY PUBLIC,STATE OF NEW YORK Registration No.01PE6328470 Sworn to before me this ,,�� onQualified inSuffolk County t 3,20 �� day of -0Cttb-er 20 1 s o- cianatnre of Anulic '4,9 a Scott A. Russell �. ' Qt51:w ve z OR MANAGEMENT 500 17501,33 TOWN HALL-z:O.Box 11 1 a •'` ''o-y n of Southold ` ri3095 Main Road-SOU 7 OX .NEW�ff19tIC 2*97i ��` 4i • ,` • .%''''444',l i to I f FRS/ CHAPTER 236 - STOI WA' ER MA AGEMEN. '.WORK STET (TO BE COMPLETED BY TIE APPLICANT) • ::_ - ::_ ___DOES traits ROJECT INVOLVE ANY O F TEE FOLLOWING:� _... (CHECK ALL THAT APPLY) Yes No 0 , A. Clearing, grubbing, grading or stripping of land which affects more than 5,000 square feet of ground surface. 0 B. Excavation or filling involving more than 200 cubic yards.of material within any parcel or any contiguous area. [l C. Site preparation on slopes which exceed 10 feet vertical rise to . 100 feet of horizontal distance. - O. Site preparation within 100 feet of wetlands, beach, bluff or coastal erosion hazard area. E. Site preparation within the one-hundred- ear floodplain as depicted on FIRM Map of any watercourse. OdiP. Installation of new or resurfaced impervious surfaces of 1,00a square . feet or more, unless prior approval of a Stolinwater Management Control Plan was received by the Town and the proposal includes - in-kind ireplacernent of im pervious surf aces. • __•_.::_ _AAAA._... - ._--AAAA -- _-.__..* �' Lim answered Nt}to all of the questions above,STOP! Complete the Applicant section below with your Dante, _ Signature,Contact Information,Date &County Tai Map Nobel'. Chapter 236 does not apply to your project. * If you answered 17.8 to one or more of the above,please submit.Two copies of a Stortm water Dfanagement Control Plan and a completed Cheek List Form to the Building'Department.wit our Building Permit Application. -..----- APPLICANT:!property own r:Desiagn Profigt oro Asa;contraeton Other) S.CTJL : I00 Dat NAME VSs%cA�]0 `( 7 6-1 to(a�(�� ''''' '‘.,__--4. - - Section Block Lot _ OR s��i�n €o DEPARTMENT arise ONLY=» t,arnrormnr� X31-(9 as 9fU� _ gam, fEckplanclauentag • Reviewed By: Date l o �(�p/ i c Pro•er-t Address/Location of Construction Work I Approved for processing Building Permit. (0S-- Br P d ! r Stormwatcr Management Control Plan Not Required_ �'r`(�_ CS :11/V:11/V . f(?3 JEl Storm water Management Control Plan is Required. (Forward to Engineering Department for Review.) FORM SMCP-TOS MAY 2014 ' I i i tt9fi IOtiF.� ' G I : i 1 't71-0-/n 11.�,0��0�SlirUr'It . Town Hall Annex 1 I • * Telephone(631)765-1802 . 54375 Main Road ; r (631)76.5 g5� P.O.Box 1179 Q �� ro ecriche IOWn.SO 0 .nv.uS Southold,NY 11971-0959 Q\Ye ^aIII�� BUILDING DEPARTMENT TOWN OF SOUTHOLD APPLICATION FOR ELECTRICAL INSPECTION REQUESTED BY: Date: `D () f.)( Company Name: • Name: • License No.: Address: • Phone No.: JOBSITE INFORMATION: (*Indicates required information) *Name: ea"dc *Address: tn'S-70.r 3 fi d`�2 fry l/9 35 *Cross Street: d *Phone No.: 01- roc, - r3-c 31 Permit No.: Lf(7a�,— Tax-Map District: 1000 . Section: $LF Block: ( Lot C- T • *BRIEF DESCRIPTION OF WORK(Please Print Clearly) joe I��Q(JYl f _go/ter e • �.a. a a ICt€) Pa e fJ (Please Circle All That Apply) *Is job ready for inspection: YES NO Rough In Final *Do-you need a Temp Certificate: 40)NO Temp Information(If needed) *Service Size: 1 Phase 3Phase 100 150 200 300 350 400 Other *New Service: Re-connect Underground Number of Meters Change of Service Overhead Additional Information: PAYMENT DUE WITH APPLICATION VPC° 82-Request for Inspection Form .k,° •, SOSOUIy® Town Hall Annex 31411Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 1179 Southold,NY 11971-0959 .- 4% I • .4° 4% February 10, 2016 III BUILDING DEPARTMENT TOWN OF SOUTHOLD Solar City 923 Motor Parkway Suite C Hauppauge NY 11788 Re: Secaida,6565 Bridge Lane,Cutchogue TO WHOM IT MAY CONCERN: The Following Items(if Checked)Are Needed To Complete Your Certificate of Occupancy: NOTE: Need certification from an architect or engineer stating the panels were installed per NYS Building Code Application for Certificate of Occupancy. (Enclosed) Electrical Underwriters Certificate. A fee of$50.00. Final Health Department Approval. Plumbers Solder Certificate. (All permits involving plumbing after 411/84) Trustees Certificate of Compliance. (Town Trustees#765-1892) Final Planning Board Approval. (Planning#765-1938) Final Fire Inspection from Fire Marshall. Final Landmark Preservation approval. Final inspection by Building Dept. Final Storm Water Runoff Approval from Town Engineer BUILDING PERMIT - 40232 — Solar Panels SoNarCity a February 16, 2016 L, Im FEB 23 2016 , Southold Town Hall Annex _ - 54375 Route 25 PO Box 1179 Southold NY 11791 Dear Inspector, I am submitting the post installation letter for: 6565 Bridge Ln Southold, NY 11971 Permit #40232 If there is anything else you may require of me, please do not hesitate to contact me at the phone number below or via email. Regards, &Ina- Fapone Gina Capone 631-835-7394 gcapone@solarcity.com 923 Motor Parkway,Ste C Hauppauge,NY 11788 r(631)625-9800 (888)SOL-CITY F(631)234-0146 solarcity.com AZ ROC 243771/ROC 245450,500277498 C4 LICd888104,CO 808041 CT HIC 0632778/ELC 0125305,DC 871101485/500002585,H1 0029770 MA 910 108572,MD t,41i IC 125948, NJ NJHIC913VH06160000/34E901732700,OR CB180498'C502,P81102.PA HICPAO7/343 TN TECL27006 1i'A SOLARC'91901,SOLARC905P7 4J 2013 SolarCmv All tights reservad i STATE OF NEW YORK WORKERS'COMPENSATION BOARD CERTIFICATE OF NYS WORKERS' COMPENSATION INSURANCE COVERAGE la.Legal Name&Address of Insured(Use street address only) lb.Business Telephone Number of Insured (650)963=5100 SolarCity Corporation 3055 Clearvlew Way Ic.NYS Unemployment Insurance Employer San Mateo,CA 94402 Registration Number of Insured 49-892777 WorkLocation of Insured(Only required if coverage is specifically ld.Federal Employer Identification Number of Insured limited to certain locations in New York State, Le, a Wrap-Up or Social Security Number Policy) 02-0781046 2.Name and Address of the Entity Requesting Proof of 3a. Name of Insurance Carrier Coverage(Entity Being Listed as the Certificate Holder) American Zurich insurance Company 3b.Policy Number of entity listed in box"la" Town of Southold WC 0182014-00 54375 Main Road Southold,NY 11971-0959 3c. Policy effective period 9/1/15 to 9/1/16 3d. The Proprietor,Partners or Executive Officers are X included. (Only check box if all partners/officers included) El all excluded or certain partners/officers excluded. This certifies that the insurance carrier indicated above in box"3" insures the business referenced above in box"la"for workers' compensation under the New York State Workers'Compensation Law.(To use this form,New York(NY)must be listed under Item 3A on the INFORMATION PAGE of the workers'compensation insurance policy). The Insurance Carrier or its licensed agent will send this Certificate of Insurance to the entity listed above as the certificate holder in box"2". The Insurance Carrier will also notify the above certificate holder within 10 days IF a policy is canceled due to nonpayment ofpremiums or within 30 days IF there are reasons other than nonpayment of premiums that cancel the policy or eliminate the insured from the coverage indicated on this Certificate. (These notices may be sent by regular mail) Otherwise,this Certificate is validfor oneyear after this form is approved by the insurance carrier or its licensed agent,or until the policy expiration date listed in box"3c",whichever is earlier. Please Note:Upon the cancellation of the workers'compensation policy indicated on this form,lithe business continues to be named on a permit,license or contract issued by a certificate holder,the business must provide that certificate holder with a new Certificate of Workers'Compensation Coverage or other authorized proof that the business is complying with the mandatory coverage requirements of the New York State Workers'Compensation Law. Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has the coverage as depicted on this form. Approved by: Lola Kanzimura (Print name of audio• d represen ;ve or licensed agent of insurance carrier) Approved by: 4, i PIt/; ilfS- q� ) (Date) Title: VP—Underwriting Manager Telephone Number of authorized representative or licensed agent of insurance carrier: (415)538-7109 Please Note: Only insurance carriers and their licensed agents are authorized to issue Form C-105.2. Insurance brokers are NOT authorized to issue it. V A�® CERTIFICATE OF LIABILITY INSURANCE D08/14/2ATE 015Dmrr) THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED ' REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT MARSH RISK& INSURANCE SERVICES NAME:PHONE 345 CALIFORNIA STREET,SUITE 1300 WC.No.Ext): A/C.No): CALIFORNIA LICENSE NO.0437153 E-MAIL SAN FRANCISCO,CA 94104 ADDRESS: Attn:Shannon Scott 415-743-8334 INSURER(S)AFFORDING COVERAGE NAIC# 998301-STND-GAWUE-15-16 INSURER A:Zurich American Insurance Company 16535 INSUREDINSURER B:American Zurich Insurance Company 40142 SolarCity Corporation 3055 Clearview Way INSURER C:N/A N/A San Mateo,CA 94402 INSURER D: INSURER E: INSURER F: COVERAGES CERTIFICATE NUMBER: SEA-002681782-03 REVISION NUMBER:4 THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS INSR TYPE OF INSURANCE ADDL SUER POLICY EFF POLICY EXP LIMITS LTR .-(NSD WVD POLICY NUMBER (MM/DD/YYYY) (MMIDDIYYYY) A X COMMERCIAL GENERAL LIABILITY GL0018201600 09/01/2015 09/01/2016 EACH OCCURRENCE $ 3,000,000 CLAIMS-MADE X OCCUR DAMAGE TO RENTED PREMISES(Ea occurrence) $ 3,000,000 MED EXP(Any one person)_ $ 5,000 _ PERSONAL&ADV INJURY $ 3,000,000 GEN'L AGGREGATE LIMIT APPLIES PER GENERAL AGGREGATE $ 6,000,000 POLICY PR X LOC PRODUCTS-COMP/OP AGG $ 6,000,000 OTHER. SIR $ 250,000 A AUTOMOBILE LIABILITY BAP018201700 09/01/2015 09/01/2016 COMBINED SINGLE LIMIT $ 5,000,000 (Ea accident) X ANY AUTO BODILY INJURY(Per person) $ x ALL OWNED x SCHEDULED BODILY INJURY(Per accident) $ AUTOS AUTOS NON-OWNED PROPERTY DAMAGE X HIRED AUTOS x AUTOS Per accident) $ _ Deductible $ 100,000 UMBRELLA LIAB OCCUR EACH OCCURRENCE $ EXCESS LIAB CLAIMS-MADE AGGREGATE $ DED RETENTION$ $ B WORKERS COMPENSATION WC018201400 09/01/2015 09/01/2016 X PER OTH- AND EMPLOYERS'LIABILITYSTATUTE ER A ANY PROPRIETOR/PARTNER/EXECUTIVE Y/N WC018201500(MA) 09/01/2015 09/01/2016 E.L.EACH ACCIDENT $ 1,000,000 OFFICER/MEMBER EXCLUDED' n N/A (Mandatory In NH) E L DISEASE-EA EMPLOYEE $ 1,000,000 If yes,descnbe under 1,000,000 DESCRIPTION OF OPERATIONS below E L DISEASE-POLICY LIMIT $ DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached if mom space is required) Evidence of insurance. CERTIFICATE HOLDER CANCELLATION Town of Southold SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE 54375 Main Road THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Southold,NY 11971-0959 ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE of Marsh Risk&Insurance Services I Charles Marmolejo C.. ..."--77. 7. ---e---(----:—S. ©1988-2014 ACORD CORPORATION. All rights reserved. ACORD 25(2014/01) The ACORD name and logo are registered marks of ACORD SUFFOIK COUNTY DEPT OF LABOR. f ucst &CONSUMER AWN= HOME IMPROVEMENT f" CONTRACTOR LICENSE q.• SHAUN E CHAPMAN This certifies that the sum"'we SCAR WY CORPORATION bearer is duly licensed by the • essee County of Suffolk ,52057-1-1 080/2013 02101/2017 =FMK COUNTY CEPT ciP LABOR, LICENSING&CONSILVER AFFAIRS ELECTRICIAN • • 414/L) -••,' JASON KANE ramarimmuilme This oatilie3 Uri the "mm bearer is duly SOLAR CRY CORP. licensed by the County c?Suffalic e= 51331-ME rOS/1VMM 12014a1C120129 034n2rn7 • • • • Version#52.6-TBD P SoIarCity PIL October 23, 2015 RE: CERTIFICATION LETTER Project/Job# 119934 Project Address: Secaida Residence 6565 Bridge Ln Cutchogue, NY 11935 Design Criteria: -Applicable Codes= 2010 Residential Code of NY State,ASCE 7-05,and 2005 NDS -Risk Category= II -Wind Speed = 120 mph, Exposure Category C -Ground Snow Load = 20 psf -MP1A AND 2B: Roof DL=9.5 psf,Roof LL/SL= 19.5 psf(Non-PV Areas), Roof LL/SL= 14 psf(PV Areas) - MP3: Roof DL= 10.5 psf, Roof LL/SL= 12 psf(Non-PV Areas), Roof LL/SL= 6 psf(PV Areas) Note: Per IBC 1613.1; Seismic check is not required because Ss=0.20021 < 0.4g and Seismic Design Category(SDC) = B < D To Whom It May Concern, A jobsite survey of the existing framing system of the address indicated above was performed by a site survey team from SolarCity. Structural evaluation was based on site observations and the design criteria listed above. Based on this evaluation,I certify that the existing structure directly supporting the PV system is adequate to withstand all loading indicated in the design criteria above based on the requirements of the applicable existing building and/or new building provisions adopted/referenced above. This review relies on the roof's structural system having been originally designed and constructed in accordance with the building code requirements and having been maintained to be in good condition. Additionally,I certify that the PV module assembly including all standoffs supporting it have been reviewed to be in accordance with the manufacturer's specifications and to meet and/or exceed all requirements set forth by the ASCE 7 standards for loading. The PV assembly hardware specifications are contained in the plans submitted for approval. Additi•:: :-: ary of the structural review is provided in the results summary tables on the following page. 0 W Y 6 I/1:1 . � *I ! E, ��11 ,r Paul Zacher, P.E. r sis.�; o15t ,, Professional Engineer n. 14.1 T: 916.961.3960 x101 1 .�� email: paul@pzse.comP • 31 sst`� �,p X91365.'( RQFESS►O\ 3055 Clearview Way San Mateo,CA 94402 T(650)638-1028 (888)SOL-CITY F(650)638-1029 solarcity.com AZ ROC 243771 CA CSEH 8888104,CO EC 8041,CT HIC 0632778 DC HRC 7110,186,DC HIS 71101488,HI CT-29770,MA HIC 168572 MD MHIC 128948,NJ I2 VH(7816060-o OR CC4 180408 P.077313,TX MIR 27006 WA 7,01_SOLARC*91007(7 7013 So,arCtty Ali rights re^•trvod Version#52.6-TBD °`�* PIL �� SoIarCity HARDWARE . . , , DESIGN AND STRUCTURAL ANALYSIS RESULTS SUMMARY TABLES Landscape ' Hardware-Landscape Modules'Standoff Specifications e . Hardware• X-X Spacing X-X Cantilever Y-Y Spacing Y-Y Cantilever - Configuration Uplift DCR MP1A AND 2B 64" 24" 39" NA Staggered 75.0% MP3 64" 24" 39" NA Staggered 83.4% Portrait ,, , , e >, „Hardware,-,Portrait Modules'Standoff Specifications . Hardware X-X Spacing X-X Cantilever Y-Y Spacing Y-Y Cantilever Configuration Uplift DCR MP1A AND 213 48" 18" 65" NA Staggered 93.5% MP3 32" 16" 65" NA Staggered 69.3% Structure `Mounting-Plane-Framing - Qualification Results ° Type ' 1 Spacing Pitch. Member Evaluation Results MP1A AND 2B r Pre-Fab Truss @ 16 in.O.C. 20° Member Impact Check OK MP3 Stick Frame @ 16 in.O.C. 45° Member Impact Check OK Refer to the submitted drawings for details of information collected dunng a site survey. All member analysis and/or evaluation is based on framing Information gathered on site.The existing gravity and lateral load carrying members were evaluated in accordance with the IBC and the IEBC. 3055 Clearview Way San Mateo,CA 94402 r(650)638-1028 (888)SOL-CITY F(650)638-1029 solarcity.com AZ SOC 243'71 CA CSLB 888104 Cl EC 314' 07 HIC 0102778 DC HO 11101486 PC HIS 71101489,HI Cl 28770 MA HIC/68572 MD MHIC 127043 SCJ 13VH0418'0600 OP 005 160498 PA 677343 TX iOIS"7008,5,A GCL SOLARC'91907 872013 St,larCty Al nghts re.urvod _.J iSTRUCTUREAANALYSIS- LOADING SUMMARY AND MEMBER CHECK- illI AND 2B. Member Properties Summary MP1A AND 2B Horizontal Member Spans Rafter Properties Overhang ' 1.16 ft , Actual W 1.50" ' 'Roof System Properties ' Span 1- v_ 5.69 ft - Actual D ' 3.50" " Number of Spans(w/o Overhang) 2 Span 2 5.73 ft Nominal Yes Roofing Material, • - ' Comp Roof' , Span 3 '- '•, , A . ' 5.25 in.^2 . Re-Roof No Span 4 S, 3.06 in.^3 Plywood Sheathing -, ., , Yes , Span 5 .. ,:, I., . 5.36,in.^4 Board Sheathing None Total Rake Span 13.39 ft TL Defl'n Limit 120 Vaulted Ceiling No 7 _ PV 1 Start 1.33 ft `Wood Species . SPF , Ceiling Finish 1/2"Gypsum Board PV 1 End 11.67 ft Wood Grade #2 Rafter Slope 20° , " LPV 2 Start' Fb ' ' 875°psi" Rafter Spacing 16"O.C. PV 2 End F„ 135 psi Top Lat Bracing T, '-,Full PV 3Stan, -,E. ,' ,1400000psi,W Bot Lat Bracing At Supports PV 3 End Emin 510000 psi - . Member Loading Summary - N Roof•Pitch, , „5/12 Initial 4 Pitch Adjust Non-PV Areas PV Areas ,. Roof Dead Load DL 9.5 psf x 1.06 10.1 psf 10.1 psf PV Dead-Load. = ,-, PV-DL 3.0 psf z 1'.06 ; - -` 3.2 psf Roof Live Load RLL 20.0 psf x 0.98 19.5 psf Live/Snow Load ' ' "" ' ' LL/ Li' '. ' 20.0'psf , x 0':7. 'x 0.7 ' 14.0 psf - '''' 14.0'psf' Total Load(Governing LC)' - TL 24.1 psf . ' 27.3 psf Notes: 1. ps=Cs*pf;Cs-roof,Cs-pv per ASCE 7[Figure 7-2] 2. pf=0.7(Ce)(Cr)(Is)p9; Ce=0.9,Ct=1.1,I5=1.0 , , - Member Design'Summary.(per--.NDS) , Governing.Load Comb ; , - , CD , CL(+) CL(-) ' , CF Cr D+ S 1.15 1.00 „ 0.95 1.5 1.15 tuber Analysis Results Summary „ . - , Governing Analysis Pre-PV Demand Post-PV Demand Net Impact Result ' Gravity Loading Check -619 psi -556 psi 0.89 Pass ..___.) tAcCULATION tiFZDESIGN WIND-LOADS7-"M PIA-AND-2B — ' ' " r ''' Mounting Plane Information . , , , . Roofing Material _ Comp Roof i5V75ystem_Typem'.-,;„___::___L__" Spaphing Vents No Standoff(A7tfaciiMarif 7Hardware) ' . ' ' — ' ' '' 7776inii7M-iii.inf7tWe't7 Roof Slope 20° FlaftSpacing ,,„„- - - ,, -= - , -, , i60.ç7:— Framing Type/Direction Y-Y Rafters Purim Spacing,__ -,„,_.,',..: ,,-:.L..,...x-xeuilins only Tile Reveal Tile Roofs Only NA „ Tile AtticTimept SYsterri -,'" ' '_- Tile'Reofs Only _ - . - '..,,, - 1 NA Standing Seam/Trap Spacing SM Seam Only NA Wind Design Criteria Wind Design Code _ ASCE 7-05 Wind Design Me_thogt_L__ „________ _ Basic Wind Speed V 120 mph Fig. 6-1 _ __ __ ,Ekpo_suretegor , -„ , , , ,„- ,, ,..„.„, :„1- L, ,L,,,Li„___,I__;_„_,,:;_,C,,,,_ Roof Style Gable Roof Hg.6-11B/C/D-14A/B Mean Roof Height ' '-'- , *' - ' _' 'h '. ,' - ='' — :-15 ft -' L- ' - .,`,. Section,6.2 ,— Wind Pressure Calculation Coefficients Wind Pressure Exposure Ic 0.85 _ Table 6-3 _ Topographic.fp4gr ,:, -_- ,,, ' .- :,:,:,7_kt ,-._ :_-__:, . 7, _ _7 --7 : -1,00 7 -. ,- : :7 7 7r-ection, Wind Directionality Factor Kd 0.85 Table 6-4 Importance Factor . ,,, "' ':jA ''', :- ' ' 'T .7 , ' ., ,,, 77-7-7 , -, :17:677, : 7-- , --- .H,,:---775-Table,64 qh = 0.00256(Kz)(Kzt)(Kd)(VA2)(I) Velocity Pressure Clh Equation 6-15 26.6 psf „ - Wind Pressure, Ext. Pressure Coefficient(Up) GC p(Up) -0.88 Fig.6-11B/C/D-14A/B Ext.Pressure Coefficient(Down), ., -', ', GC (Down) 0.45 ''' '' ' '' ,,'' ' " r'fig.)6-11B/C/O-14A/B Design Wind Pressure .13 p=qh(GC) Equation 6-22 Wind Pressure Up Nun) -23.3 psf ' Wind Pressure Down" ' Ihdown) , 12.0 psf ' — X-Direction - ' Y-Direction Max Allowable Standoff Spacing Landscape , 64" 39" ,Kax,Allpwable_Cahtilever,.. _____ .: -Canc175-caPP__,.. - „-,___.11;—ZI4",...---",..,..---,'m.,---I., ,Sta ndoff Configuration Landscape Staggered Trib, ', ,,,_: -_;, -._ ,,,, ',_. :,,, ,,',. 17 sf _, .: ,,,_,_,,,,-2_,_,,,2_____:_y„: _-, -, ,•,, -._, PV AssembiyDeadLpad _ -W-PV -3.0 psf N7eiWinC1'6 n.lifi_af§tariiiiiti 7 "-', _ '7 f-aciiiaf-7::7"'77 I-7N 747!--iiii'77 7,..7777-7-7'"—"7 5tindOff D'emaril/Eipacity- - ,- EICIT , - - - ---7 , 75'.0610- :. =7- X-Direction Y-Direction Max Allowable Standoff Spacing Portrait 48" 65" Rax,Allowable:Cantileyer_t---,..:,.',--...—.. ..eo_rfra.it _,_,_,...:,,,,.,.., ...'..,,..—,,,.;., ....,...........,.,......1P1,... Standoff Configuration Portrait Staggered 22,sf' ' ; PV Assembly Dead Load W-PV 3.0 psf -__ Uplift Capacity of Standoff _ T-allow 500 lbs Standoff Demand/Capacity , 'STRUCTURE ANALYSIS- LOADING SUMMARY AND MEMBER CHECK- MP3 Member Properties Summary MP3 Horizontal Member Spans Rafter Properties Overhang 1.16 ft Actual W 1.50" Roof System Properties Span 1 - 11.84 ft Actual D 7.25" Number of Spans(w/o Overhang) 1 Span 2 Nominal Yes Roofing Material Comp Roof Span 3 A 10.88 in.^2 Re-Roof No Span 4 SX 13.14 in.^3 Plywood Sheathing Yes Span 5 ° ' -Ix - 47.63 in.^4 Board Sheathing None Total Rake Span 18.38 ft TL Defl'n Limit 120 Vaulted Ceiling No PV 1 Start 0.58 ft , , Wood Species SPF Ceiling Finish 1/2"Gypsum Board PV 1 End 12.33 ft Wood Grade #2 Rafter Slope 45° PV 2 Start - Fb 875 psi Rafter Spacing ' 16"O.C. PV 2 End F„ 135 psi Top Lat Bracing., Full PV 3 Start E ' 1400000 psi Bot Lat Bracing At Supports PV 3 End Emin 510000 psi Member Loading Summary Roof Pitch 12/12 Initial Pitch Adjust Non-PV Areas PV Areas Roof Dead Load DL 10.5 psf x 1.41 14.8 psf 14.8 psf PV Dead Load PV-DL 3.0 psf x 1.41 4.2 psf Roof Live Load RLL 20.0 psf x 0.60 12.0 psf Live/Snow Load . LL/SL"2 20.0 psf x 0.54 I x 03 10.8 psf- .6.0 psf Total Load(Governing LC) TL 25.6 psf . 25.1 psf Notes: 1. ps=Cs*pf;Cs-roof,Cs-pv per ASCE 7[Figure 7-2] 2. pf=0.7(Ce)(Ct)(Is)py; Ce 0.9,Ct=1.1,I5=1.0 Member Design Summa (per NDS) Governing Load Comb CD CL(+) CL(-) CF Cr D+ S 1.15 1.00 0.37 1.2 1.15 mber Analysis Results Summary Governing Analysis Pre-PV Demand ,Post-PV Demand Net Impact Result Gravity Loading Check 537 psi 525 psi 0.97 Pass +_CALCULATION OF DESIGN WIND LOADS--MP3 -_ ___ . ^ ;_ Mounting Plane Information Roofing Material Comp Roof � -PVSysem Type_ ----71:7-----:_77 . - 7_ —_— So-6rCitySleekMoun0TM L__� w.77,--------. .7:I-- Spanning _a `_ Spanning Vents _ ___ _______ No ____ __._____ Standoff(Attachment Hardware) ' Comp Mount Type C Roof Slope ___ 45° _ Rafter Spacing_ _.._-__-_--w____.--...------7------ _.. ._.._ ~ 16"Q.C. ____ Framing Type/Direction Y-Y Rafters Purlin Spacing+._ _,____X.-X,Purlins,Only W. .______ _ NA _, __..;..w..._..._....,.. .._...� ._____ Tile Reveal Tile Roofs Only _ NA _ _ _ file,Attachment System _ �. Tile Roofsly,mm On __ _„ __ _ .__ ___ NA n __ _, Standing Seam/Trap Spacing SM Seam Only NA Wind Design Criteria - , Wind Design Code _ ASCE 7-05 Wind Design Method - 7---T----- - - -, �.,. _�,.� _—Partially/Fully Enclosed Method . _R.. ,7'- 'w-µ”P— Basic Wind Speed ___-, __M ^ V -ma„ �_ _120 mph Fig. 6-1_ Exposure Category - _ + - C _ Section 6:5.6.3 Roof StyleGable Roof Fig.6-11B/C/D-14A/B Mean Roof Height h � 15 ft . .. _...�- .m.___— , . Section 6.2 Wind Pressure Calculation Coefficients , Wind Pressure Exposure KZ0.85 Table 6-3 Topographic actor ._` Krt _ u Y _0.85 �� ��Section6.5.7 Wind Directionality Factor __ Ka _._„. _ 0.85 Table 6-4 Importance Factor I , '� 1.0 _ _ --Table 6-1 Velocity Pressure qh qh = 0.00256(11z)(Kzt)(Kd)(V^2)(I) Equation 6-15 26.6 psf Wind Pressure Ext. Pressure Coefficient(Up) GCp(Up) -0.95 Fig.6-11B/C/D-14A/B Ext. Pressure Coefficient(Down) GCp(Dpwn) . 0.88 Fig.6-11B/C/D-14A/B Design Wind Pressure p p=qh(GC„) Equation 6-22 Wind Pressure Up Prup) -25.3 psf Wind Pressure Down prdowio 23.3 psf ' (ALLOWABLE STANDOFF SPACINGS - .____..�_ __; ____ X-Direction Y-Direction Max Allowable Standoff Spacing Landscape ___ _ 64" _ 39" Max Allowable Cantile_v_er _ _Landscape_,__- 24" ____________ NA, Standoff Configuration Landscape Staggered Max Standoff Tributary Area Trib, , , _ 17 sf ___ _ ____ PV Assembly Dead Load W-PV~ _ 3.0 psf Net Wind Uplift_at Standoff � Tactual -v ------7— -417 lbs 4----__": �: ` — Uplift Capacity of Standoff _ T allow__ 500 lbs _ �_ Standoff Demand/Capacity DCR " , 83.4% X-Direction Y-Direction Max Allowable Standoff Spacing Portrait 32" 65" Max.Allowable Cantilever ,Portrait , _ �_ _ 16 __ , ' „w __NA__ Standoff Configuration Portrait Staggered Max Standoff Tributary Area _,__,_ Tribes . _._.._ __ ___ 14 sf . PV Assembly Dead Load _ W-PV 3.0 psf ___ �_ Net Wind Uplift at Standoff _,�_„�,, �_ T.-actual_ v _— -347 lbs Uplift Capacity of Standoff T-allow500 lbs Standoff Demand/Capacity T 15C127----77 -y _ 69.3% - ' --77 7-777— ( ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES A AMPERE 1. THIS SYSTEM IS GRID-INTERTIED VIA A AC ALTERNATING CURRENT UL-LISTED POWER-CONDITIONING INVERTER. BLDG BUILDING 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. CONC CONCRETE 3. A NATIONALLY-RECOGNIZED TESTING t t' i' CODES OF DC DIRECT CURRENT LABORATORY SHALL UST ALL EQUIPMENT IN CO %if�L �f,�„�1 ALL EGC EQUIPMENT GROUNDING CONDUCTOR COMPLIANCE NTH ART. 110.3. /ED M V N r;�,�-,'; STATE & TOWN CODES (E) EXISTING 4. WHERE ALL TERMINALS OF THE DISCONNECTING DATE 11) L- l B.P.# �a AS REQUIRED ,, v ; T , SF EMT ELECTRICAL METALLIC TUBING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, - iriint r�Tn1gIAl 7R] FSB FIRE SET-BACK A SIGN WILL BE PROVIDED WARNING OF THE FFE:L0 _ BY S�I�X GALV GALVANIZED HAZARDS PER ART. 690.17. T Y BUILDING DEPARTMENT AT ' -'BARD GEC GROUNDING ELECTRODE CONDUCTOR 5. EACH UNGROUNDED CONDUCTOR OF THEo• 'l '�`�' GND GROUND MULIIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY ;c5 1802 8 AM TO 4 PM FOR THE HDG HOT DIPPED GALVANIZED PHASE AND SYSTEM PER ART. 210.5. 1=0LLOVVING INSPECTIONS: __ SOli?HOLD TOWN TRUS I i Ea I CURRENT 6. CIRCUITS OVER 250V TO GROUND SHALL FOUNDATION TWO REQUIRED N.Y.S.DEC Imp CURRENT AT MAX POWER COMPLY WITH ART. 250.97, 250.92(B). FOR POURED CONCRETE -— Isc SHORT CIRCUIT CURRENT 7. DC CONDUCTORS EITHER DO NOT ENTER 2; ROUGH - FRAMING & PLUMBING kVA KILOVOLT AMPERE BUILDING OR ARE RUN IN METALLIC RACEWAYS OR 3. INSULATION kW KILOWATT ENCLOSURES TO THE FIRST ACCESSIBLE DC 4. FINAL - CONSTRUCTION MUST LBW LOAD BEARING WALL DISCONNECTING MEANS PER ART. 690.31(E). BE COMPLETE FOR C.O. ELECTRICAL MIN MINIMUM 8. ALL WIRES SHALL BE PROVIDED WITH STRAIN ALL CONSTRUCTION SHALL MEET THE (N) NEW RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY REQUIREMENTS OF THE CODES OF NEW 54Sp cTIO i' NEUT NEUTRAL UL LISTING. YORK STATE. NOT RESPONSIBLE FOR NTS NOT TO SCALE 9. MODULE FRAMES SHALL BE GROUNDED AT THE DESIGN OR CONSTRUCTION ERRORS. OC ON CENTER UL-LISTED LOCATION PROVIDED BY THE PL PROPERTY LINE MANUFACTURER USING UL LISTED GROUNDING POI POINT OF INTERCONNECTION HARDWARE. ECILIMED PV PHOTOVOLTAIC 10. MODULE FRAMES, RAIL, AND POSTS SHALL BE SCH SCHEDULE BONDED WITH EQUIPMENT GROUND CONDUCTORS. S STAINLESS STEEL ` STC STANDARD TESTING CONDITIONS TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT Vmp VOLTAGE AT MAX POWER VICINITY MAP INDEX Voc VOLTAGE AT OPEN CIRCUIT W WATT . 3R NEMA 3R, RAINIIGHT _ i PV1 COVER SHEET `I PV2 SITE PLAN �'"'•° '' PV3 STRUCTURAL VIEWS .• Imo. ' 4 :t.. ' ""'" PV4 THREE LINE DIAGRAM �E� LICENSE GENERAL NOTES ��� • Cutsheets Attached . Tom., 1. ALL WORK SHALL COMPLY WITH THE 2010 t R.C.N.Y.S. . . . - 2. ALL ELECTRICAL WORK SHALL COMPLY WITH , x ti. , THE 2008 NATIONAL ELECTRIC CODE. . •' . -" .^t_" 4! MODULE GROUNDING METHOD: ZEP SOLAR `- ' ` u `�.,wS` - .. . REV BY DATE COMMENTS AHJ: Southold Town -'A /`'`''` �' ' s • i ? mum DATE COMMENTS * • 1 ,' / �,•-�©©© * UTILITY: PSE&G-Long Island (Public Service Electric " ' I _ �. ---_ `'- ~� ©©© * & Gas co.) ©2015 • DigitalGlobe; New York GIS, USDA Farm Service Agency©©© * JB-119934 00 PREMISE°W"� DESCRIPTION: DESIGN: CONFIDENTIALCONTAINED A THE INFORMATION HEREIN JOB NUMBER .,,SolarCit CONTAINED SHALL NOT BE USED FOR THE SECAIDA, JUAN SECAIDA RESIDENCE John Sauvigne �. a " MEM OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTBI: �'�" r NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 6565 BRIDGE LN 12.22 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES: r' TCHOGUE NY 11935 ORGANIZATION,EXCEPT IN CONNECTION WITH , w Way THE SALE AND USE OF THE RESPECTIVE (47) TRINA SOLAR # TSM-260PD05.18 PAGE NAME sIEEr RETE DAIS S 3055 geaan Mateo,CA 8Way SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: T:(650)638-1028 F:(650)638-1029 PERMISSION OF SOLARCITY INC. Multiple Inverters (631) 806-7831 COVER SHEET PV 1 10/21/2015 (888)-931.—CITY(765-2489)www.solorltyco„ PITCH: 20 ARRAY PITCH:20 MP1 AZIMUTH:31 ARRAY AZIMUTH:31 MATERIAL:Comp Shingle STORY: 1 Story PITCH: 20 ARRAY PITCH:20 MP2 AZIMUTH:211 ARRAY AZIMUTH:211 MATERIAL:Comp Shingle STORY: 1 Story PITCH:45 ARRAY PITCH:45 MP3 AZIMUTH:121 ARRAY AZIMUTH: 121 MATERIAL:Comp Shingle STORY: 1 Story 1-6-F NENYf1H_ \ K. Zgc4 0p n1• 0 9 a o 3 (E)DRNEWAYm W f33 o o 9 0 o e /0 _�p=``qua 0 o o a e� • J -V • 3115 O 91365 ,scr b C Mos A�CFESSION S aLEGEND 0 (E) UTILITY METER Sc WARNING LABEL se f ® INVERTER W/ INTEGRATED DC DISCO & WARNING LABELS F9 DC DISCONNECT & WARNING LABELS SCHANGE o— — 3 CTURE ® AC DISCONNECT & WARNING LABELS CHANGE • i i m,,__Tri u • e� o Q Front Of House ° •— Q DC JUNCTION/COMBINER BOX & LABELS Q • v • 0 O 0 ° 0 0 DISTRIBUTION PANEL & LABELS 0 o m b • • • —o LG LOAD CENTER & WARNING LABELS p O 0 O 0 ¢a �f 11 , pal "o O M DEDICATED PV SYSTEM METER 0 . m 9 ® ® 0 ® o STANDOFF LOCATIONS ' ' CONDUIT RUN ON EXTERIOR 0 ©oo CONDUIT RUN ON INTERIOR . — GATE/FENCE 0 HEAT PRODUCING VENTS ARE RED It ;I INTERIOR EQUIPMENT IS DASHED L-_'..1 SITE PLAN 01' 16' 32' s ` ■' ' >•--'✓1 ///r iii/ .4,' F JB 0 0 PREMISE OWNER. DESCPoP1ION: DESIGN: CONFIDENTIAL— NE INFORMATION HEREIN JOG NUMBER: Vil‘SO�a�C�ty CONTAINED SHALL NOT BE USED FOR NE SECAIDA, JUAN SECAIDA RESIDENCE John Sauvigne BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: NOR am.IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 6565 BRIDGE LN 12.22 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES CUTCHOGUE NY 11935 ORGANIZATION, EXCEPT IN CONNECTION WITH 3055 Clean/law Way THE SALE AND USE OF THE RESPECTIVE (47) TRINA SOLAR # TSM-260PD05.18 PAGE NAME SHIfL RLV ppTE San Mateo,CA 94402 SOLARgTY EQUIPMENT, WITHOUT NE WRITTEN UIVER7ITR _ T:(650)638-1028 F:(650)638-1029 PERMISSION OF SOLARCITY INC. Multiple Inverters (631) 806-7831 SITE PLAN PV 2 10/21/2015 (888)—SOL—CITY(765-2489)www.9olarcitYaan, . . . ,:,, ® \i„ 0, :, 00,1.0 3' jido":.„,,ig'...s 4�-: OF NEW N . • -�1 ISI 5'_g" 5'—g" �i� 40 g� 5'-8" 5'-9" *�' rI311 , � I 1'— � (E) LBW E Ikr-M11 �s .;�;—;,. � 1 _ 1, (E) LBW SIDE VIEW OF MP1A NTS SIDE VIEW OF MP2B NTS ��,oR�1365' P��� A EssioN MP1A X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES MP2B X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES LANDSCAPE 64" 24" STAGGERED LANDSCAPE 64" 24" STAGGERED PORTRAIT 48" 18" PORTRAIT 48" 18" ROOF AZI 31 PITCH 20 TOP CHORD 2x4 @ 16" OC ARRAY AZI 31 PITCH 20 STORIES: 1 TOP CHORD 2x4 @ 16" OC ROOF AZI 211 PITCH 20 STORIES 1 BOT CHORD 2x4 @16" OC Comp Shingle �� ARRAY AZI 211 PITCH 20 BOT CHORD 2x4 @ 16 OC Comp Shingle PV MODULE 5/16" BOLT WITH LOCK INSTALLATION ORDER & FENDER WASHERS LOCATE RAFTER, MARK HOLE ZEP LEVELING FOOT (1) LOCATION, AND DRILL PILOT ZEP ARRAY SKIRT (6) HOLE. (4) (2) SEAL PILOT HOLE WITH ZEP COMP MOUNT C POLYURETHANE SEALANT. i:WA► r j ® ZEP FLASHING C ;`��t�� �_■S: (3) INSERT FLASHING. (E) COMP. SHINGLE i�I v'� C.4.) PLACE MOUNT. 4 i 11'-10" (E) ROOF DECKING YAM INSTALL LAG BOLT WITH — � (E) LBW - 5/16" DIA STAINLESS (5) E SEALING WASHER. STEEL LAG BOLT LOWEST MODULE SUBSEQUENT MODULES INSTALL LEVELING FOOT WITH © SIDE VIEW OF MP3 NTS WITH SEALING WASHER (6) BOLT & WASHERS. (2-1/2" EMBED, MIN) MP3 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES (E) RAFTER LANDSCAPE 64" 24" STAGGERED STANDOFF PORTRAIT 32" 16" 41) . RAFTER 2X8 @ 16"OC ROOF AZI 121 PITCH 45 STORIES:1 Scale: 1 1/2" = 1' - ARRAY AZI 121 PITCH 45 C.J. 2x8 @16"OC Comp Shingle J B-119934 00 PREMISE OWNER: DESCRIPIION: DESIGN: CONFIDENTIAL—THE INFORMATION HEREIN ,I�NUMBER ���la ■ CONTAINED SHALL NOT BE USED FOR THE SECAIDA, JUAN SECAIDA RESIDENCE John Sauvigne � :SoIarC�ty, BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: •,a 1 NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 6565 BRIDGE LN 12.22 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES: CUTCHOGUE, NY 11935 ORGANIZATION, EXCEPT IN CONNECTION WITH3055 Clean/lee Way NE SALE AND USE OF THE RESPECTIVE (47) TRINA SOLAR # TSM-260PD05.18 PAGE NAME SHEE REV: DATE San Mateo,CA 94402 PERSOMISSIONCITY EOFISOLARCITY INC.T THE WRITTEN INVERTER, 631 806-7831 PV 3 10/21/2015 (88)(SOL,CIIY(765-2489)50)www.salarc corn Multiple Inverters ( ) STRUCTURAL VIEWS GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE . BOND (N) #8 GEC TO (E) GROUND ROD Panel Number:TM2020CB Inv 1: DC Ungrounded INV 1-(1)A813 #PN-4.2-OUTD-S-US-Z-A LABEL A -(47)TRINA SOLAR ## TSM-260PD05.18 AT PANEL WITH IRREVERSIBLE CRIMP Meter Number:79 982 461 Inv 2: DC Ungrounded FG Inverter; Zigbee 4200W, 240V, 989." PV Module; z50W, 236.9W PTC, 40MM, Black Frame, H4, ZEP, 1000V Overhead Service Entrance Tie-In: Supply Side Connection INV 2-(1)ABB#Pm-6000-0111D-US-Z-A Lpg0B FG Inverter; Zlgbee 6000W,240V, 96.5%" Voc: 38.2 Vpmax: 30.6 INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER E 200A MAIN SERVICE PANEL (E) 200A/2P MAIN CIRCUIT BREAKER ADJUST MIN. ACTIVATION VOLTAGES! SolarCity CUTLER-HAMMER BRYANT • Inverter 1 IND 12 Disconnect 11(N) 125A Load Center gO ABB 6 oc+ Vstart=200V B 60A PVI-4.2-OUTD-S-US-Z-A oG MP3: 1x10 -I • •�•-- C 25A/2P _ EGC J i • A ^ - r / y I 41) 200A 2P s r--�•�l n1• • N �� DG IQ VStdl t=200V ��J(E) LOADS D _y+_, 1 Q r_ GEC �� 1DC- 'EDC- MP2: 1x11 I -i�--�'��• L J V II I + GND I EGC ---1 - 1-GC / J }=_ixn�J v ADJUST MIN. ACTIVATION VOLTAGES! (1)Conduit Kit; 3/4'EMT N 1 Inverter 2 IND $ 3 Vstart=200V • o io ABB f DG MP3: 1x13 z_ I PVI-6000-OUTD-US-Z-A 35A/2P /� r Ecc c1-1-] GEC '. _ LI- ® V T F- L2- ✓ DC+ 1 Q - - -- TO 120/240V �., ! N �� DC- I O 1CDc+ Vstart= 200V ' SINGLE PHASE ' I L_ --__- EGC/ A •� oc+ /� e /___ UTILJTY SJ7tVICE I GEC 1 -•� DGL --_ e 7G 4 MPl: 1x13 I 11 I r GND I EGC L ', - v GC 1 J I IV I 1 (1)Conduit Kit; 3/4°EMT -1- EGC ON ROOF TO BE ROUTED WHERE NOT SUBJECT TO PHYSICAL DAMAGE. WHEN ROUTED SUBJECT TO PHYSICAL DAMAGE THE SIZE MUST BE INCREASED TO #6 SOLID BARE COPPER. Voc* = MAX VOC AT MIN TEMP POI-(2)ILSCO IPC 4/0-#6 B -(I)OUTLER-HAMMER DG222NR8 AC A -(1)SolarCitY,p 4 STRING JUNCTION BOX Insulation Piercing Connector; Main 4/0-4,Tap 6-14 Disconnect; 60A, 24OVac, Fusible. NEMA 3R /y 2x2 STRMGS UNFUSED, GROUNDED DC -(1)CUTLER-HAMMER I DG100NB SSC-SUPPLY SIDE CONNECTION. DISCONNECTING MEANS SHALL BE SUITABLE Ground/Neutral Kit; 60-100A, General Duty(0G) AS SERVICE EQUIPMENT AND SHALL BE RATED PER NEC. -(1)CURER-HAMMER#DSI6FK Class R Fuse Kit - -(2) F�RRAZ SHA 250,#ClIR6ORKS PV BACKFEED OCP ' C 1-(1)BRYANT#BR48LI25RP Load Center; 125A, 120/240V, NEMA 3R -(1) (1)Br�H 25A/2P, 2 Spaces -(1)Break H 35A/22P, 2 Spaces -(1)AWG#6, 1HWN-2, Black ^ (1)AWG#10, THWN-2, Black -(1)AWG#10, THWN-2,Black Voc* =473.99 VDC Isc =9 ADC ^ (2)AWG#10, PV Wire, 600V, Black Voc* =430.9 VDC Isc=9 ADC © g-(1)AWG 16, THWN-2, Red (. �1 1 L(1)AWG#10, THWN-2,Red O Q-(1)AWG#10, THWN-2,Red Vmp =336.6 VDC Imp=8.5 ADC ( I ) (1)AWG#6, Solid Bare Copper EGC Vmp =306 VDC Imp=8.5 ADC -(1)AWG#6, IHWN-2, White NEUTRAL Vmp =240 VAC Imp=48 MC `J 666 (1)AWG#10, THWN-2,White NEUTRAL Vmp =240 VAC Imp=20 MC (1)AWG p10, THHN/1HWN- ..Green. EGC .. .�. . • -(1 AWG 18,.THWN-2,_Green . EGC/GEC-(1)Conduit Kit; 3/4° EMT . .. _ . ..-(1)AWG#8, 1H,WN-2,Green .. EGC/GEC-(1)Conduit Kit; 3/4°EMT.. ._. (1)AWG 110, THWN-2, Black Voc* =430.9 VDC Isc=9 ADC -(2)AWG#10,PV Wire, 600V, Black Voc* =473.99 VDC Isc=9 ADC -(1)AWG 16, THWTI-2, Black -(1)AWG#8, 1HWN-2,Black © 1-(1)AWG 110, THWN-2, Red Vmp =306 VDC Imp=8.5 ADC O g-(1)AWG#6,Solid Bare Copper EGC Vmp =336.6 VDC Imp=8.5 ADC (1-...-) i-(1)AWG 16, 1HWN-2, Red -(1)AWG#8, 1HWN-2,Red -77(1)AWG 110, 1HHN/1HWN-2, Green EGC _ .. . . • • • • (1)AWG 16, THWN-2 White NEUTRAL Vmp =240 VAC Imp=48 MC ---(1)AWG#10, THWN-2, White NEUTRAL Vmp =240 VAC Imp=28 MC -(1)AWG#10, 1HWN-2, Black Voc* =560,16 VDC Isc =9 ADC -(2)AWG#10, PV Wire,600V, Black V• oc* •=560.16VDC Isc=9 •ADC 7%0)AWG 116, Solid Bare Copper GEC . -(1)Conduit Kit; 3/4'EMT, -(1)AWG#8,.1HWN-2, Green EGC/GEC-(1)Conduit Kit; 3/4'EMT O cd-(1)AWG 110, THWN-2, Red Vmp =397.8 VDC Imp=8.5 ADC O c (1)AWG#6, Solid Bare Copper EGC Vmp =397.8 VDC Imp=8.5 ADC ---(1 AWG#10, IHHN/THWN-2, Green EGC • (1)AWG 110, 1HWN-2,Black Voc* =560.16 VDC•Isc=9 • ADC• •(2)AWG#10, PV Wire, 600V, Black • V• oc* =560.16 VDC•Isc=.9.• ADC ®I§-(1)AWG#10, THWN-2,Red Vmp =397.8 VDC Imp=8.5 ADC ® (1)AWG#6, Solid Bare Copper EGC Vmp =397.8 VDC Imp=8.5 ADC (1)AWG#10. THHN/THWN-2. Green FGC J B-119934 00 PREMISE OWNER: DESCRIPTION: DESIGN: CONFIDNEDAL- THE IN BER USED HEREIN JOB NUMBER: \� SolarCityCONTAINED SHALL NOT BE USED FOR THE SECAIDA, JUAN SECAIDA RESIDENCE John SauvigneBENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNIING SYSTEM: NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 6565 BRIDGE LN 12.22 KW PV ARRAY PART 10 OTHERS OUTSIDE THE RECIPIENT'S MooUlES CUTCHOGUE, NY 11935 ORGANIZATION, EXCEPT IN CONNECTION WITH 3055 Clearview Way THE SALE AND USE OF THE RESPECTIVE (47) TRINA SOLAR # TSM-260PD05.18 PAGE NAME SHE]T: REV DAZE San Mateo,CA 94402 -1029 PERMISOLASSIONCITY EOFIPMENT,SOLARCITY INC.T THE WRITTEN INVERTER: (631) 806-7831 THREE LINE DIAGRAM PV 4 10/21/2015 (888)T(SOL'CITY(765-2489)50)riaww..ssoolarctycorn Multiple Inverters ( WARNING:PHOTOVOLTAIC POWER SOURCE Label Location: Label Location: Label Location: (C)(CB) WARNING (AC)(POI) WARNING (DC) (INV) Per Code: Per Code: Per Code: ELECTRIC SHOCK HAZARD ELECTRIC SHOCK HAZARD NEC 690.31.G.3 DO NOTTOU_CH TERMINALS.—= NEC 690.17.E THE DC CONDUCTORS OF THIS NEC 690.35(F) Label Location: TERMINALS ON BOTH LINE AND PHOTOVOLTAIC SYSTEM ARE TO BE USED WHEN PHOTOVOLTAIC DC (DC)(INV) LOAD SIDES MAY ENERGIZED UNGROUNDED AND INVERTER IS IN THE OPEN POSITION MAY BE ENERGIZED DISCONNECT Per Code: UNGROUNDED NEC 690.14.C.2 Label Location: Label Location: PHOTOVOLTAIC POINT OF (P01) MAXIMUM POWER- (DC) (INV) INTERCONNECTION EPer Code: POINT CURRENT R-_A WARNING: ELECTRIC SHOCK Per Code: HAZARD. DO NOT TOUCH NEC 690.17.4; NEC 690.54 MAXIMUM POWER POINT VOLTAGE(Vmp) V NEC 690.53 TERMINALS.TERMINALS ON _ MAXIMUM SYSTEM BOTH THE LINE AND LOAD SIDE VOLTAGE(Voc)_V MAY BE ENERGIZED IN THE OPEN SHORT-CIRCUIT POSITION. FOR SERVICE CURRENT(Isc)._A DE-ENERGIZE BOTH SOURCE AND MAIN BREAKER. PV POWER SOURCE MAXIMUM AC _ A OPERATING.CURRENT MAXIMUM ACV Label Location: OPERATING VOLTAGE WARNING (DC) (INV) Per Code: ELECTRIC SHOCK HAZARD IF A GROUND FAULT IS INDICATED NEC 690.5(C) NORMALLY GROUNDED Label Location: CONDUCTORS MAY BE CAUTION (P01) UNGROUNDED AND ENERGIZED DUAL POWER SOURCE Per Code: SECOND SOURCE IS NEC 690.64.6.4 PHOTOVOLTAIC SYSTEM Label Location: WARNING (DC) (CB) ELECTRICAL SHOCK HAZARD Per Code: Label Location: DO NOT TOUCH TERMINALS NEC 690.17(4) CAUTION (D)(P01) TERMINALS ON BOTH LINE AND Per Code: LOAD SIDES MAY BE ENERGIZED PHOTOVOLTAIC SYSTEM NEC 690.64.6.4 IN THE OPEN POSITION CIRCUIT IS BACKFED DC VOLTAGE IS ALWAYS PRESENT WHEN SOLAR MODULES ARE EXPOSED TO SUNLIGHT Label Location: WARNING (P01) Per Code: INVERTER OUTPUT Label Location: NEC 690.64.6.7 - PHOTOVOLTAIC AC (AC) POI)( ) DO CONNECTION NOT RELOCATE (AC):AC Disconnect, DISCONNECT Per Code: THIS ODEVICERRENT (C): Conduit NEC 690.14.C.2 (CB): Combiner Box (D): Distribution Panel (DC): DC Disconnect (IC): Interior Run Conduit Label Location: (INV): Inverter With Integrated DC Disconnect MAXIMUM ACA (AC)(P01) (LC): Load Center OPERATING CURRENT Per Code: (M): Utility Meter MAXIMUM AC V NEC 690.54 P01): Point of Interconnection OPERATING VOLTAGE ( CONFIDENTIAL— THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR �0 44 3055 Gearview Way THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC.,NOR SHALL IT BE DISCLOSED �= San Mateo,CA 94402 IN WHOIE OR IN PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, aP T(650)638-1028 F(650)638-1029 EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE Label Set x/11 kink '�� (888)-SOL-QTy(765-2489)www.solarcRy.wm SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. ° Additional highlights: - . - Solar Inverters RS 485 communication interface ABB string inverters logger)vection to laptop or data s PVI-5000/6000-TL-OU IT D - Integrated Arc Fault Detection and Interruption(-A Version). 5kW to 6kW - Ali f c Technical data and types Type code PVI-5000-OUTD-US PVI-6000-OUTD-US Allli` I i Input side I _ :v T;" {7.t7+-x, �'�a" Nominal output power 5000W 6000W - - - - ' '-'''yi p ?s_(,;:‘,1,,,..,.,".'-j ,_ Maximum output power 5000W 6000W . Rated grid AC voltage 208V 240V 277V 208V 240V 277V - - . "f I Input side(DC) , ° i Number of independent MPPT channels 2 Maximum usable power for each channel 4000W Absolute maximum voltage(Vmax) 600V `,°,_,_..—.- -- -_-.1 Start-up voltage(Vstart) 200V(adj.120-350) Full power MPPT voltage range 200-530V t Operating MPPT voltage range 0 7 x Vstart-580V Maximum current(Idcmax)for both MPPT in parallel 36A r1' Maximum usable current per channel 22A 1)• Number of wire landing terminals per channel 2 Pairs Array wiring termination Terminal block,pressure clamp,AWG16-AWG6 I Output side(AC) Grid connection type 10/2W Split-0/3W 10/2W 10/2W Split-0/3W 10/2W Adjustable voltage range(Vmin-Vmax) 183V-228V 221 V-264V 244V-304V 183V-228V 211 V-264V 244V-304V Grid frequency 60Hz Adjustable grid frequency range 57-60.5Hz Maximum current(la°.,,°,)A 27Aa 23A. 20A. 30A. 28A 24A.. Desi ned for residential and small The wide input voltage range Highlights: Power factor >0 995 g Total harmonic distortion at rated power <2% commercial PV installations,this makes the inverter suitable to low _ Single phase and split phase output Contnbutoryfault current' 36 25 A°k/ 36 5 A°,�/ 31 75 A°„/ 36 25 A°„/ 36 5 A°k/ 31 75 A°k/ inverter fills a specific niche in the power installations with reduced grid connection 25 63AAMa 25 81A.mi 22 45AAMa 25 63AAM 25 81A a 22.45AAu6 P Grid wiring termination type Terminal block,pressure clamp,AV?G14-AWG4 ABB product line to cater for those string size. - Wide input range for increased llnput,,, , ,. , = I The transformerless operation offers Reverse polarity protection Yes installations producing between stringing flexibility. Reverse pOver-voltageprotection type Varistor,2 for each channel 5kW and 20kW. high performance efficiencies of up to _ The high speed and precise MPPT yp 97.1%. PV array ground fault detection Pre start-up Riso and Dynamic GFDI(requires floating arrays) algorithm offers real time power Eoutput I Free remote monitoring capabilityAnti-islandingprotection Meets UL 1741/IEEE1547 requirements Meets UL 1741/IEEE1547 requirements This inverter includes dual input tracking and improved energy 9 9 section toprocess two strip s with available with every installation.This harvesting° Over-voltage protection type Varistor,2(L,-Li/L,-G) Varistor,2(L,-6/L,-G) p g enables homeowners to view their Maximum AC OCPD Rating 35A 30A 25A 40A 35A 30A independent MPPT. - Outdoor NEMA 4X rated enclosure I Efficiencyd The high speed and precise MPPT energy production and offers installers for unrestricted use under any Maximum efficiency 97.1% algorithm offers real-time power a proactive and economic way of environmental conditions. CEO efficiency 96% 96 5% 96 5% 96% 96 5% 96 5% trackingand energyharvestin maintaining and troubleshooting the _ Integrated DC disconnect switch User interface Graphic display Graphic display g system. {Operating performance Flat efficiency curves ensure highin compliance with international Stand-by consumption <8W <6W� efficiency at all output levels ensuring Standards(-S Version) Night time consumption <0 6W°,,,° <0 6W°,° I Communication - - consistent and stable performance User-interface 16 characters x 2 lines LCD display across the entire input voltage and Remote monitonng(1xRS485 incl) VSN700 Data Logger(opt) output power range. Wired local monitoring(1xRS485 incl) PVI-USB-RS485_232(opt.) l Environmental This outdoor inverter has been -13°F to+140°F(-25°C to+60°C)with Ambient air operating temperature range -13°F to+140°F(-25°C to+60°C) derating above 122°F_(50°C) designed as a completely sealed unit to Ambient air storage temperature range -40°F to+176°F(-40°C to+80°C) -40°F to+176°F(-40°C to+80°c) withstand the harshest environmental Relative humidity 0-100%RH condensing 0-100%RH condensing conditions. Acoustic noise emission level <50 db(A)Q1 m <50 db(A)@lin AL ID It Maximum operating altitutde without derating 6560 ft(2000 m) 6560 ft(2000 m) Power and productivity 2 Inverter can apply that much current-Breaker will open for a better world'"" �� 1P 2 ABB Solar Inverters I Product flyer for PVI-5000/6000-TL-OUTD L Additional highlights: .c=�= k Iv,tI lit `4«E .- THE Tr nnmounf MODULE TSAR®PD05.18 Mono Multi Solutions I ;)j.;r; r , .f...4:4•-• {,;I d DIMENSIONS OF PV MODULE ELECTRICAL DATA @ STC r'. unit.mm Peak Power Watts-Pwx(Wp) 245 • 250 255 260 %n s.#{ ,, ,'' I 941• ;Power Output Tolerance-PMnx(%) - 0-+3 •'tj^ ti r)1 F.t — - 3— Maximum Power Voltage-VE.w(V) 29 9 30 3 30 5 30 6 IHEibrinarn 0 U n t t r ' [.,,,...1.A G DN v. I7""1 }' 1 o i Maximum Power Current-IM°r(A) 8.20 B 27 8 37 8 50 T t t (,a.. E TV ' ER A F u Open Cucud Voltage-Voc(V) 37 8 38 0 38 1 38 2 F; :}, to s.,:•° 'i E \Disrnua+GNOLE ,Short Circud Current-Isc(A) 8 75 8 79 8 86 9.00 fif T I rModule 15 0 .15 3 15.6 15 9M ®ULE �L _ Efficiencynml )lt : t Y I 1 1 rs • STC Irradiance 1000 W/m',Cell Temperature 25°C,Alr Mass AMI 5 according to EN 60904-3 s w, Typical efficiency reduction of45%at 200 W/m'according to EN 60904-1 'ills' I.. 'It , to _ ` � o ELECTRICAL DATA @ NOCT i O _ �r1:-%""---,-.4.4,..I• °•°i ,Mawmum Power-Pianx(Wp) 182 186 190193 1 } ; Maximum Power Voltage-V r(V) 27 6 28 0 2881 1 28 3 ,1'� "`- ) 'Ma ximum Power Current-IMPa`(A) 6 59 6.65 6 74 6 84 ` ai beta GROUNDING NOTE ( MULTICRYSTALLINE MO®ULE ;' 'tt>, z /„-0uwNOTE A A I Open Circuit Voltage(V)-Voc(VJ 351 • 352 353 354 r , WITH-TRINAMOUNT FRAME , ”'``}r ,; •° i t e ;# i 1 Short Circuit Current(A)-Isc(A) 707 710 717 727 {- _9 L NOCT Irradiance at 800 Wm'.Ambient Temperature 20°C.Wind Speed l m/s I a.,245•-260W ' PD05 18 812 180 Back View ' I POWER OUTPUT RANGE, MECHANICAL DATA - d -'-"" 11 Solar cells 'Multicrystalline 156 x 156 mm(6 inches) _ ' F% Fast and simple to install through drop in mounting solution t Cell orientation 60 cells(6.10) - __ - ^ / Module dimensions ( ) h 15.970 1650.992 x 40 mm 64 95.39.05 x 1 57 inches { ■5.9 i._,.,.! `r 3 Weight '21 3 kg(470lbs) - - j .MAXIMUM EFFICIENCY - • Glass 3 2 mm(0 13 mches),High Transmission,AR Coated Tempered Glass --_� A-A Backsheet '4 White _ r� ` Good aesthetics for residential applications •Frame . Black Anodized Aluminium Alloy with Trinamount Groove ( I-V CURVES OF PV MODULE(245W) J-Box • 'r IP 65 or IP 67 rated - 0~�3� Cables Photovoltaic Technology cable 4 0'mm'(0.006 inches'),- - 10. ; 1200 mm(47 2 inches) _ - POWER OUTPUT'GUARANTEE 9.-1000W/mr Fire Rating Type 2 i 1, 7m�800W/m' >____-----m.-_�_�_ -.._��-_ - - '''-`', Highly reliable due to stringent quality control `6°°--a5O m rrIR „ • Over 30 in-house tests(UV,TC,HF,and many more) d s� As a leading global manufacturer -I j` • In-house testing goes well beyond certification requirements 4°° 7 TEMPERATURE RATINGS MAXIMUM RATINGS of next generation photovoltaic ,..4, 3°° roducts,we believe close 2m 205W/m' Nominal Operating Cell 44°C(+2°C)' Operational Temperature -40-+85°C P1 m Temperature(NOCT) Maximum System 1000V DC(IEC) cooperation with our partners 0. 5 ! •Temperature Coefficient of Pmex -0 4l%/°C Voltage . 1000V DC(UL) I is critical to success -With local 0. tom 20. 30. 40°° i ! ' presence around the globe,Trina is , Voltage(v) Temperature Coefficient of Voc -0 32%/°C ` Max Series Fuse Rating i 15A able to provide exceptional service _--- erature Coefficient of Isc 0 OS%/°C to each customer in each market -•? Certified to withstand challenging environmental Temperature Co---- --- -----5-/-- and supplement our innovative, (�=1� ; conditions reliable products with the backing ` ' • 2400 Pa wind load WARRANTY • of Trina as a strong,bankable • 5400 Pa snow load partner. We are committed _ , 10 year Product Workmanship Warranty to building strategic,mutually - - - beneficial collaboration with - '25 year Linear Power Warranty installers,developers,distributors . (Please refer to product warranty for details) _ a and other partners as the n backbone of our shared success in CERTIFICATION I driving Smart Energy Together LINEAR PERFORMANCE WARRANTY � PACKAGING CONFIGURATION m - 10 Year Product Warranty•25 Year Linear Power Warranty t.a�7 usrFn sA u Modules per box 26 pieces wi Trina Solar Limited • Irr ,,, I Modules per 40'container.728 pieces J wwwtnnasolarcom `6100% ISO • Addl}l°nal value ho COMPLIANTE E 0 90% I t - 'I mrrina SOlafgl�nepr Warran� . CAUTION READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT aoMPAT'O T• (` /'y I^ `o r (` (�{ 02014 Trina Solar Limited All rights reserved Specifications Included in this datasheet are subject to H• rinas0ILA1 O 80% ,_,rig: `�... �,. ". ® �� .7®�t.7� change without notice Smart Energy Together 25 Smart Energy Together Aea ,v Years 5 10 15 20 ®Trinastandard 0 industry,csnoard - i- THE Tr amount MODULE TSM-P®05.18 Mono Multi Solutions . ' } , , I i , -i f'-1 L r r; I. I; DIMENSIONS OF PV MODULE ELECTRICAL DATA®STC �. I I I' unit.mm Peak Power Watts-Pswo(Wp) 250255 260 265 ® -- i '-I-" I - ; 1 i I 941 p Power Output Tolerance-Prwx(%) 0-+3 s. —s' a Mdximum Power Voltage-Vrw(V) 30 3 30 5 30 6 30 8 THETrnar'riou rl fi UNRpN G ; j i, ,1 B0% Maximum Power Current-IMPP(A) 8 27 8.37 8 50 8 61 'tt..-- .)r I N"A""aTr o Open Circuit Voltage-Voc(V) 38 0 38 1 38 2 38 3 i ,j ;; I ) �''•""" j I i Short Circuit Current-Isc(A) 8 79 8.88 9 00 910 11 I =iiiG No,E S E i i Module Efficiency qm(%) 15 3 15 6 15 9 16 2 L rC. i r STC Irradiance 1000 W/m',Cell Temperature 25°C,Air Mass AM1 5 according to EN 609045-39 0904-3 j, f t q. 1 Typical efficiency reduction of 4 5%at 200 W/mt according to EN 60904-I •rr ' )rl I tt o ELECTRICAL DATA @ NOCT {'•. -. , ' r T I ' ,Maximum Power-Nax(Wp) 186 190 193 _ 197 60 CELL ,- - . i Maximum Power Voltage-Vw(V) 28 0 28 1 28 3 28 4 , .. 1-,_ -- _ ,- ° Maximum Power Current-lop,(A) 6 65 6 74 6 84 6 93 MULTICRYSTALLINE MODULE 6043 olouNowG MOS A A I PD05.18 a.oxnw Na Open Circuit Voltage(V)-Voc(V) 35 2 35 3 35 4 35 5 , WITH TRINAMOUNT FRAME Short Circuit Current(A)-Isc(A) 710 i 717 727 735 _d/L O NOCT Irradiance of 800 W/mt,Ambient Temperature 20°C wind Speed 1 m/s '250-265W 812 180 . Back View MECHANICAL DATA POWER'OUTPUT RANGE solar cells Multicrystalline 156 x 156 mm(6 Inches) 11, j Cell orientation 60 cells(6 x 10) __ Fast and simple to install through drop in mounting solution { Module dimensions 1650.992.40 mm(64 95 x 39 05 x 1 57 inches) -_fti. L :/�� :Weight 19'6 kg(43 12IbsJ { Glass 3 2 mm(0 13 inches),High Transmission,AR Coated Tempered Glass , MAXIMUM EFFICIENCY Backsheet •White A-A '"�`- Frame Black Anodized Aluminium Alloy Good aesthetics for residential applications { " , s t J-Box - IP 65 or IP 67 rated . vim./y �, Cables I Photovoltaic Technology cable 4 0 mm'(0 006 inches'), 0 ti+3 SO 1200 mm(47 2 inches) - 14 CURVES OF PV MODULE(260W) Connector H4 Amphenol ( POSITIVE POWER TOLERANCE °°° -' 9W s000w/m' Fire Type UL 1703 Type 2 for Solar City ,-_ . . _ .f -- ._. E ®.ti Highly reliable due to stringent quality control °°° 200w/m• �, • Over 30 in-house tests(UV,TC,HF,and many more) T0° As a leading global manufacturer ` °1 • In-house testing goes well beyond certification requirements a °°° G°Gw/mt TEMPERATURE RATINGS MAXIMUM RATINGS of next generation photovoltaic • PID resistant �` 'qoo Nominal Operating Cell • ,Operational Temperature j-40-+85°C products,we believe close " 400W/r01 Temperature(NOCT) ;44°C(±2°C) , cooperation with our partners 300 1 , I Maximum System : 1000V DC(IEC) , zoo �mw/m' ` ,Temperature Coefficient of Pnvx -0 41%/°C i Voltage 1000V DC(UL) i is critical to success With local 1 I j-- - presence around the globe,Irma is 00 �`11 Temperature Coefficient of Voc -0 32%/°C 'Max Series Fuse Rating { 15A able to provide exceptional service 6-�, 'o�o io zo 3o 4o so 1 Temperature Coefficient of Isc 0 OS%/°C to each customer In each market -v % Certified to withstand challenging environmental 1 Temperature_re___.___.--�- _-__ and supplement our innovative, y conditions volume,/ reliable products with the backing • 2400 Pa wind load of Trina as a strong,bankable '- • 5400 Pa snow load WARRANTY partner We are committed 10 year Product Workmanship Warranty to building strategic,mutually CERTIFICATIONI 25 year Linear Power Warranty i - - 1 beneficial collaboration with i—--------------------------- installers,developers,distributors n cous a (Please refer to product warranty for details) ai and other partners as the us= u us backbone of our shared success in �—� I �' dnving Smart Energy Together LINEAR PERFORMANCE WARRANTY ��� Imo° L_JE PACKAGING CONFIGURATION f toMPUANI -- Z 10 Year Product Warranty•25 Year Linear Power Warranty Modules per box 26 pieces Trina Solar Limited - - www tnnasolar com vlpa%- I Modules per 40�container 728 pieces - m Additloaal Value horn Tilna polar's Ilaepr y 90% o Warr CAUTION® CAUTION READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT axot9P4T�e o - .2015 Irina Solar Limited All rights reserved Specifications Included in this datasheet are subject to N �r1p�(,®lar �r'n�s®lar change without notice Smart Energy Together 25 Smart Energy Together acOM Years 5 10 15 20 11 Trina standard 0liwustrysoandard