Loading...
HomeMy WebLinkAbout40073-Z • ,,'o,,pSUEFati� Town of Southold 2/22/2016 � i P.O.Box1179 t. ��# 53095 Main Rd ', of �,�0�' ' Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 38108 Date: 2/22/2016 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 2265 Mill Rd,Peconic SCTM#: 473889 Sec/Block/Lot: 67.-7-5.1 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 8/27/2015 pursuant to which Building Permit No. 40073 dated 9/10/2015 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: ROOF MOUNTED SOLAR PANELS TO EXISTING ONE FAMILY DWELLING AS APPLIED FOR The certificate is issued to Norman-King,Marylou of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 40073 11-19-2015 PLUMBERS CERTIFICATION DATED Authorized Signature ;, OFFo TOWN OF SOUTHOLD BUILDING DEPARTMENT f y s TOWN CLERK'S OFFICE 'o SOUTHOLD, NY ='viol * le;v BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 40073 Date: 9/10/2015 Permission is hereby granted to: Norman-King, Marylou 73 Primrose Ave Floral Park, NY 11001 To: Install roof-mounted solar panels on existing single-family dwelling as applied for. At premises located at: 2265 Mill Rd, Peconic SCTM # 473889 Sec/Block/Lot# 67.-7-5.1 Pursuant to application dated 8/27/2015 and approved by the Building Inspector. To expire on 3/11/2017. Fees: SOLAR PANELS $50.00 CO -ALTERATION TO DWELLING $50.00 ELECTRIC $100.00 Total: $200.00 Building ector Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings,property lines, streets, and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal (S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1%lead. 5. Commercial building, industrial building,multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings(prior to April 9, 1957)non-conforming uses,or buildings and "pre-existing" land uses: 1. Accurate survey of property showing all property lines, streets,building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant.If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00,Alterations to dwelling$50.00, Swimming pool$50.00,Accessory building$50.00,Additions to accessory building$50.00,Businesses$50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy-$.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy-Residential $15.00,Commercial$15.00 Dated v•6\••IS New Construction: Old or Pre-existing Building: (check one) Location of Property------"*. oS l�1 RAI.( U� ���' h t c) 1 DILL � I tcts-v House No. Street Hamlet Owner or Owners of Propertya: Suffolk County Tax Map No 1000, Section O(Pr Block r Lot 6 Subdivision Filed Map. Lot: Permit No. 14009 r7 j Date of Permit. Applicant: Health Dept.Approval: Underwriters Approval: Planning Board Approval: Request for: Temporary Certificate Final Certificate: V (check one) Fee Submitted: $ OD, 1* I pplicant Signature '',„,, iii.._�� '��' • SO(/jiko Town Hall Annex �� ® Telephone(631)765-1802 54375 Main Road : z Fax(631)765-9502 P.O.Box 1179 G Q 0 roger.richertRtown.southold.ny.us Southold,NY 11971-0959 . ,9 a C®UtdT`t:sr.”i BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION Issued To: Norman-King Address: 2265 Mill Road City: Peconic St: New York Zip: 11958 Building Permit# 40073 Section: 67 Block: 7 Lot 5 1 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: Built Well Solar License No: 52602-ME SITE DETAILS Office Use Only Residential X Indoor Basement Service Only Commerical Outdoor X 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures HID Fixtures Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel ( NC Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel NC Blower Range Recpt Fluorescent Fixture Pumps Transformer Appliances Dryer Recpt Emergency Fixtures Time Clocks i Disconnect Switches Twist Lock Exit Fixtures TVSS Other Equipment 3.965 kw Roof Mounted Photovoltaic System to Include, 13- 305w Panels with 13-250w Micro Inverters Notes: Ins Si � • � Inspector nature: p gII,r Date: November 19, 2015 Electrical 81 Compliance Form.xls '''4soojl ,rte o\ # * JJJ _ r ,'Y�OUPli`I,�,,•r yo TOWN OF SOUTHOLD BUILDING DEPT. _ 765-1802 INSPECTION - - [ ] FOUNDATION 1ST [ ] ROUGH PLUMBING [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) feELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] CAULKING REMARKS: DATE l 14 INSPECTOR 111111,y■ 11, 11, ■ 111 • 11111111 •' • 111 • 11 .1 • • • • • • JAMES J. S TOUT A RCHITECT & Assoc . ' 2 G REG L ANE E AST NORTHPORT N. Y. 631 — 8 58 9388 1J i` If 5 Post Installation Letter November 05, 2015 i i--:'\\ rm\ _____ -- RE: King Residence , l - . �� 1'�-,�,' 1 c 016 I mill Road#2265 I l iI FEB 9 2 Peconic, NY 11958 r To Whom It May Concern: This letter is to confirm that as of this date November 5, 2015, I, James J Stout, NYS license 021633 have personally inspected the placement and installation of the roof top solar panels at the above listed address.All of the solar panels have been installed as per manufacturer's guidelines and specifications. The racking system design and installation complies with the 2010 building code of NYS section 1609 and all related provisions. The panel wattage was changed from LG 300 W (3.9 kW system) to LG 305 W(3.965 kW system). The installation was done as per plan. Thank you for your cooperation in this matter. Thank you for your cooperation in this matter. James J. Stout Architect et 4). . 4, ,„ ...„ , jj, * im' ^A. FIELD IN'SPEO"STON REPORT DATE COM,I �ITS • FOUNDATION(1ST) . Y _ _ . , , .r • . _,21 • • , . .•. . • FOUNDATION(2ND) --- -� Cq tzi • •-•��+ r ROUGH FNg& PLUMBING ., ....._.... - " • • • • INSULATION PER N.Y. --`.'�`--` . . , H STATE ENERGY CODE _.�.,- , , 1 " ' - . . . . .. . - •r-1 . . • -. , -. • ' l 'T-,... F]NAL l i . Y • • • -• • rif rat T5 •'�•"'�.. ~•'. .. . . . . ._,_ a -ail 04 c. F731 • .4`,...z93),_ q,P01/67,, , . ., ,. . . . ... ,, ,,.• .:'•'. ;,'• - ‘.- .: '','. . - 7. : .- ,..,, ,1. rri 0 Z . .. . 1 • .).) •2 . • • • • .-.C^ • .41 • IV TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD,NY 11971 4 sets of Building Plans TEL: (631) 765-1802 Planning Board approval •,. • FAX: (631) 765-95024/6,0 �✓2 - _ Survey SoutholdTown.NorthFork.net PERMIT NO. Check _ ,Septic Form - , , N.Y S D.E.0 Trustees C.O.Application Flood Permit Examined •• 20 l Single&Separate Storm-Water Assessment Form ______q_A6_: , Contact: , , Approved 20 ! Mail to: Disapproved a/c c Phone: ' Expiration * /111 ,20 /7 , 40 D �, ;; ' i_ j; r Builth - pector i I'',I�'LICATION FOR BUILDING PERMIT Lin AUG 2 7 2015 I U, 1 ,J i Date LLS l ,411 ,20 0 5 INSTRUCTIONS v iv - se- .mp a .is app ica ion letely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans,accurate plot plan to scale.Fee according to schedule. b.Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas,and waterways. c.The work covered by this application may not be commenced before issuance of Building Permit. . d.Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. , e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. , f. Every building permit shall expire if the work authorized has not commenced within 12 months after the'date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize,in writing,the extension of the permit for an addition six months Thereafter,a new,permit shall be required. _ - APPLICATION IS HEREBY MADE to the Building Department for.the issuance of a Building Permit pursuant to the •Building Zone Ordinance of the Town of Southold, Suffolk County,New York,and other applicable Laws,Ordinances or Regulations,for the construction of buildings,additions,or alterations or for removal or demolition,as herein described,The applicant agrees to comply with all applicable laws,ordinances,building code,housing code,and regulations,and to admit authorized inspectors on premises and in building for necessary inspectio•_ '� W‘ /l�f :"gnat :e of applicant or name,if a corporation) /L aG_ I UL ♦ LA l* (Mailing address of applicant, /17 State whether applicant is owner, lessee, agent, rchitect engineer, general contractor, electrician, plumber or builder Ay_dici. ifcck Name of owner of premisesv r i(' ( s o the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer , • (Name and title of cor orate officer) Builders License No. 4ri`�9--(4 Dan Sado - Plumbers License No. - Electricians License No,. 52-0002''H 5 4 OM eAik r Other Trade's License No. 1. Location of land owhich roped work will be done: PG j N'/ I I dI 5� lesWI( Ro 1 House Number StreetHamlet . ,, , County Tax Map No. 1000 Section ?(0 T7 Block 17 Lot • 511 Subdivision Filed Map No. Lot 2. State existing use and occupancy of premises and irltpnded use and oc upancy of proposed construction: a. Existing use and occupancy S(1�G�� fr f l I/'e�( ri('e J 1 b. Intended use and occupancy 3. Nature of work(check which applicable): New Building Addition Alteration Repair Removal Demolition Other Work),W__.144_.144 PD Q (Description) 4. Estimated Cost Fee (To be paid on filing this application) 5. If dwelling, number of dwelling units Number of dwelling units on each floor If garage, number of cars 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of existing structures, if any: Front Rear Depth Height Number of Stories Dimensions of same structure with alterations or additions: Front Rear Depth Height Number of Stories 8. Dimensions of entire new construction: Front Rear Depth Height Number of Stories 9. Size of lot: Front , Rear . Depth 10. Date of Purchase Name of Former Owner 11. Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law, ordinance or regulation? YES NO 13. Will lot be re-graded? YES NO Will excess fill be removed from premises? YES NO 14. Names of Owner of remises h-t 0(S k.L nq . Address?,1405 eta d Phone No. Name of Architect„la &5 SkblJiJ Address l(s'r 1.a�6 NR,p1Phone No]p 3145 V•-Q38? Name of Contractor€Wl IMAgitSAW/Dan Sg11j4Address5/(°-015'loop Phone No`3o't i&u f (1 Won ,6hN\/ tl q3 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO VJ * IF YES, SOUTHOLD TOWN TRUSTEES &D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO ✓t * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey,to scale,with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. 18. Are there any covenants and restrictions with respect to this property? * YES NO 's/ * IF YES,PROVIDE A COPY. STATE OF NEW YORK) SS: COUNTYIOF • C J L1`1 A CJ S-6,4— being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)He is the V O f (Contractor,Agent,C w orate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained m this application are true to the best of his knowledge and belief;and that the work will be performed in the manner set forth in the application filed therewith. SCOTT pIFiORE Notary Public,State of New York Sworn to before me this N°Q(2uallfied in Suffolk County _ 2 S day of 4,1n5i, 20 l5Nsslon 6346°7 co, � es0511112019 leferf 4� M7 my ��, Notary Public S'_ .e. e of Applicant ir e-°SL'r�� • �T(0)RMWATER Scott A. Russell N � � ��: � SUPERVISOR U o ( r MANAGEMENT SOUTHOLD TOWN HALL-P.O.Box 1179 ) �] 53095 Main Road-SOUTHOLD,NEW YORK 11971 1 /P��0�-� ....... Town of 1Sou th o i -• 1 Y-11>`,„ CHAPTER 236 - STORMWVATER MANAGEMENT WORK SHEET ( TO BE COMPLETED BY THE APPLICANT) DOES THIS PROJECT INVOLVE ANY OF THE FOLLOWING: i Yes No . (CHECK ALL THAT APPLY) : •j D N A. Clearing, grubbing, grading or stripping of land which affects more than 5,000 square feet of ground surface. D Ji B. Excavation or filling involving more than 200 cubic yards of material , _ . within any parcel or any contiguous area. DM C. Site preparation on slopes which exceed 10 feet vertical rise to . 100 feet of horizontal distance. D]I D. Site preparation within 100 feet of wetlands, beach, bluff or coastal erosion hazard area. 3 Del E. Site preparation within the one-hundred-year floodplain as depicted i - on_F1RM Map of any watercourse, - D[1j-F. lnstallation of-nevi or resurfaced impervious surfaces of 1,000-square-1-- - feet or more, unless prior approval of a Stormwater Management Control Plan was received by the Town and the proposal includes - in-kind replacement of impervious surfaces. If you answered NO to all of the questions above, STOP! Complete the Applicant section below with your Name, Signature, Contact Information, Date & County Tax Map Number! Chapter 236 does not apply to your project. If you answered YES to one or more of the above, please submit Two copies of a Stormwater Management Control Plan and a completed Check List Form to the Building Department with your Building Permit Application_ s APPLICANT: (Property Owner.Design Professional,Agent.Contractor.Other) -C'T-M' 'r. I Dorm Date uct " i 5 / NAME. V i•"_ , w N I\�Vi 't Section Block Lot , 61'511 IJ - 40 �f • aA FOR BL_ L DING L:N RTNI_-i i LSI: ONLY Contact In . ati. r U•En i,3e6 f 64,i,\,��nReviewed By. ���- '•'"''i — Date- Pro•ert Address / Locat ion of Construct ion Work_ 02aJI f:(I I Re tsI 'n ,e) ��(> ►\ 1013 X Approved for proceung Building Permit r Y (�tN r✓t N 1 Stormwater Management Control Plan Not Required Ston mwater Management Control Plan a Required (For watd 10 Engineering Depnumnt (or fir view) FORM - " MCP TOS \--LAY i()1,1 11/1312015 13:59 TAX) P.002/002 0 3004,' /40' cfli tA , Tp1Nj01 Hall Annex 41 ilig ; Telephone(631)765.1802 _ 34,375 IKam Road ' 681 765ti45g4� P.O.Box 1179 $` er:rj t)U e n .0 Southold,NY 11971-0959 It, • BUILDING DEPARTMENT - TOWN OF SOUTHOLD !a iCATIO FOR ELECTRICAL INSPE TION REQ. U STED BY: i c h cA a •r Date: it, la, v11.5 Company Name: \I JJ Name: .� iii i\ `1 so\c - un. SG�1 d, • License No.: 52 -Q, +m, _ Address: ki1go 5,An.;ise.. l - ‘‘,,,+as,,,; 3ti5 Wa,-�a k _._.i______}.) u i 9 3 Phone No.: - 5 t to- 6 ot S-- L.0(;)o — i b - JOBSITE INFORMATION: (*Indicates required information) - *Name: a 14 i AA / Itn a r.4 l..o.,% 01-,nn c‘ri *Address: i l e or),'L,. *Cross Street: 1(�;oi- i ,4..e�.�� Phone _.„ ....___ _ No.: 1 ,-l,Kv-S1±RR ._f _t - a1 `1-I H4 Permit No.: --- T-�— Tax-Map District: • 1000 Section: Q_ �, Block: Lot:_..S..4_1_ ' *BRIEF DESCRIPTION OF WORK(Please Print Clearly) . - S pier ipane \s . �b � Til �a l l a�igrl yn;c.ro ;nJ.e.,-kvs - • ds o wo..k.. e....1 (Please Circle All That Apply) *Is job ready for inspection: / NO. Rough In Final • *Do.you need a Temp Certificate: . YES 1(4 Temp Information(If needed) . *Service Size: 1 Phase 3Phase 100 150 200 300 350 400 Other *New Service: Re-connect Underground Number of Meters Change of Service Overhead Additional information: P E DUE WITH APPLICATION U� - • ,>. ______________________ gc::::7 _ 82-Request for Inspection Form - ' 1111312015 13:59 (FAX) P.001/002 B[ALT WEIJL SOLAR CORP. BUILT WELL ontcm 7S2 QRANP AVENUt 1SFsLLMOBe.NY 11710 �A.. MAILU4Q3280S rtsetiwY.,SEJr1 345,,buntwe lioY11793 com °1'"'� �Y�vVY,1rilI�hVC11SOltlr Cqm 5o. ' Tel (516)695-1000 FAX (516)695-1001 FAX TRANSMISSION ��SQn c11 DATE: �C) ti k\11611 -5 �--- FROM: iiriic.-h4.tka_ fart` Tel: 516• _ _. RS-- 1000 4_x+ 103 TO:ATTN: ._ ._e ri -t46..ereyvre FAX: kbthel 4-a . G (Y1 . ....... ` a .14.. . 1-hank 1 n. .,. Number of pages, Including this cover sheet: _ I_I, ilii ' ,�o1�pF SO(j161- - Town Hall Annex � Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 1179 G Q ��� Southold,NY 11971-0959 �' 0 0• � =y00UNTY,\', � December 7, 2015 BUILDING DEPARTMENT TOWN OF SOUTHOLD Well Built Solar 3280 Sunrise Hwy, Suite 345 Wantagh, NY 11793 Re: Norman-King,2265 Mill Rd, Peconic TO WHOM IT MAY CONCERN: The Following Items(if Checked)Are Needed To Complete Your Certificate of Occupancy: NOTE: Certification required by an architect or engineer stating the panels were installed to the roof per NYS Building Code Application for Certificate of Occupancy. (Enclosed) Electrical Underwriters Certificate. A fee of$50.00. Final Health Department Approval. Plumbers Solder Certificate. (All permits involving plumbing after 4/1/84) Trustees Certificate of Compliance. (Town Trustees#765-1892) Final Planning Board Approval. (Planning#765-1938) Final Fire Inspection from Fire Marshall. Final Landmark Preservation approval. Final inspection by Building Dept. Final Storm Water Runoff Approval from Town Engineer BUILDING PERMIT - 40073 - Solar Panels S'IWI E OF NEW YORK ' WORKERS' COMPENSr11'(ON BOARD CERTIFICATE OF NYS WORKERS'COMPENSATION INSURANCE COVERAGE Ia.Legal Name and Address of Insured(Use street address-only) lb.Business Telephone Number of Insured Built Well Solar Corporation (Slt'i)G95 l000 dbaa Built Well Solar Corporation ` Ic.NYS Uneinpinyinent Insurance Employer Registration 3280 Sunrise Hwy Number of Insured Ste 345 Wantagh<NY 11793-4024 Id.Federal Employer Identification Number of-Insured or Social Security Number 'Work I neation of Insured(Only rrquired/coverage is specifically 200417523 /intiwd to certain locations in Nee?}wk State.le.a Wrap.Up Policy) 2.Name andAddren of the Entity Requesting Proof of 3n.Name of Insurance Carrier Coverage fEutity Being Listed as the Certificate Holder) Continental indemnity,Co. Town al Southold Building Dept 53095 Rte 25 '3b.Policy Number of entity listed in box"lap': PO Box 1179 46.358699.01-01 Southnkl.NY 11971 3e.Polley effective period: '_ Attn:Project Manager 1(1015 - to04!10116 `- 3d,The Propletor,Partners or Executive Officers are: El included.nutty due&box hall paranenJnmcers incladcda ®all excluded or certain purtne&officers' excluded. This certifies that the insurance carrier Indicated above In box"3"insures the business referenced ahuvc in box"la"for workers' compensation under the New York Stale Workers'Compensation harry. (To use this form,New York(NY)nnist"be listed under Pent 3A on the INFORMATIONAL PAGE of the workers'compensation insurance policy). The Iimurunce Carrier or its licensed agent will send the Certilicale of insurance to the entity listed above as the certificate holder in box"2". The frts'monce C'cu'r'icr Will also motifs the',bore rvrtrficrrte holder within 10 days/P a policy is vimrcrrst due to rlarapaynrrnf n(preininrn.c or a ifflirr 30 days ir:there'ar'e ieer.wss other rhrrn rannparnrent afprerniunrs that cancel the policy or eliminate the insurer!kern!the covet axe indicated on Mis,Certif it are. (Mist'notices nary be sent by regular moil)Otherlpise,this Certificate is valid for one year after thisfarm is approved by the insurance carrier or its licenserd agent,or until die policy expiration date listed in box"k",itqf eke ve lc curlier. Please Note;Upon the cancellation of tete workers'compcnsatinn policy indicated on this form, if the husiness,.xyitinaes to he named nn a permit, ikcngc or contract issued by a certificate holder, the huciner roust provide that certificate harder with a new Certificate nl'Workers'Ct ntpel:anion Coverage or udret authorised pion(that the business is complying with the th:tbdatory coverage requirements of the New tank Sone Workers' Compensation Law, Under penalty of perjury.I certify that I um an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has the coverage a'.depicted oil this torah. Approved by: Chris LaMantia , (Print name ol'tiuthciriredl rep esetuvtive or licenced ngenl of instinmce carrier) Approved by: _ __— ______ ____.._._� 04/07/2015 ---- (Signature) (Date) , Title: ____Authorized Representative - %gettlwne Number of the-authorized representative or licensed agent of insurance currier:____(.8,7)2.3471420 __(.877}23x1-1420 Please Note:On iusatitter carriers and their licensed agents me authorized is issue the C-103.2 form. Insurance brokers are NOT authorized to issue it, C-105.2(9-117) . • OA,c_e__ .. . , JOB NO. SITE MAP GENERAL NOTES 2015-506L:011 1. SOLAR PANELS WILL BE ( 13 ) LG 300 WATT PV MODULES N - AND ( 13 ) M250 ENPHASE MICRO-INVERTERS. r E R O H I 2. PROVIDE A.C. DISCONNECT: CUTLER HAMMER DG22IVRB-30A GENERAL r DUTY SAFETY SWITCH, NON FUSIBLE, 240VAC, NEMA 3R. _ r LL r 3. THE AC DISCONNECT WILL BE LABELED AS "UTILITY DISCONNECT AND Z 0 ■ ---- PHOTOVOLTAIC SYSTEM LOCK-OUT" LOCATED WITHIN VIEW OF THE ELECTRIC Z O N UTILITY METER. O Z r 4. IF IT IS NOT PRACTICAL TO LOCATE THE AC DISCONNECT WITHIN VIEW OF j LuI ■ �' 4/ THE UTILITY METER, THEN A WEATHERPROOF PLAQUE SHOWING THE LOCATION LU Q NN OF THE SWITCH MUST BE INSTALLED WITHIN VIEW OF THE ELECTRIC UTILITY "5 METER. a r N . A0110. 5. ALL WIRING TO MEET THE NATIONAL ELECTRICAL CODE. Lf) J N 6. THE RAFTERS AS INDICATED HAVE BEEN ANALYZED AND DEEMED SUFFICIENT `' J r E. TO SUPPORT THE ADDED LOAD OF THE SOLAR PANELS AND CONNECTORS. Q r MIAVICI AVENUE 7. THE SOLAR PANELS MAY NOT BE INSTALLED ON AN EXISTING ROOF THAT 00 U y MEANSOOF SUPPORT ARE P OVIDEDHASTPER THESE DRAWINGS.ESS ADEQUATE Z W r W \ - N 0o 8. THE MAXIMUM SPACING BETWEEN THE STANDOFFS SHALL BE 66" O.C. O ...j p CC� N 33 O 9. THE SOLAR PANEL MOUNTING SYSTEM WILL BE BY UNIRAC WITH A 2 1/2" I� (/) G r ~" oo O ALUMINUM "I" BEAM. I- a W Q Ir 00 c _ ZONING INFORMATION o a p 1 rt U 200.00' N 62°45'E Id STREET ADDRESS: 2265 MILL ROAD z 0 0) Q r I x PECONIC, NY 11958 J Cr <— 0 II 0 Lll SECTION: 067 BLOCK: 7 LOT ( S ): 5.1 ILI o — r -- o 0 LINE DIAGRAM ( ) Z Jsi O 34.50O O J r E= 0T > ( Z r Tx 60 60 < SOLAR NooDlE-� • p r o N I - N MIN E TER W a ■ Z 2 STORY T Z U Q r 0 I n DWELLING ' �!� >- O^ Y N Z M r o I IXISRNG CO LL N O N E~ z CZ I Ml I _ 1 _`_ 200 AMP PANE N ¢ O 0 1-1- r (� 1— HOUSE `J ONE 21 91__ —DISI— n O I.T. 0 Cl_ N W \ Ac C°G°n STORY ''� • W I O I ENPHASE MRTE 1•.� z MICRO-INVERTER BCW JUNCTION BOX11 Ife r COMBINER NEMA 3R J O I0 M N _ W TOTAL SYSTEM SIZE: 3.9 kW Lird., B < I (n * ~ r N p DRIVEWAY O °^°°° a � c[ Lf) r) } N UJ 00 CC � _] Z 0 CD CO D Hx N iiii CO _ LO ATTACHMENT DETAIL - z � � � � ,,� CO O r 200.00' S 62°45'W ALUMINUM ALLOY VS CO r MID CLAMP SOLAR PANEL MODULES L() (V M c: 111 ''-. M is r• -,-•`4-''''' .-4'';"` ,t; NIIN T-BOLTS ALUMINUM VS RAIL BY UNIRAC ��` ��f/f is ALUMINUM ALLOY +„I E ALUMINUM ALLOY STANDOFF ' •• .• N L--FOOT \ y \ I N vi ASPHALT 1 QUICK MOUNT PV FLASHING q. '• � - %���///j r ROOF SHINGLE r:� d • c+ � lr. r 1/4 EXISTING ROOF ill 1.5:::::4,1111,.,,C.L:......1.!7r1:11 ~SHEATHING,I 5/16'X 3 1/2'STAINLESS STEEL I • rEXISTING ROOF RAFTER LAG BOLTS INTO CENTER OF ROOF �� • r �) RAFTER, MINIMUM 2" EMBEDMENT. fHI11111N a` r - z 1 ii l FL I - -- ----- ---- ------- ------ RETAIN STORM WATER RUNOFF PURSUANT TO CHAPTER 236 OF THE TOWN CODE. ELECTRICAL APPROVED AS NOTED INSPECTION REQUIRED DATE: �.P. �b 3 2 FEE:5 r ® BY: t1= NOTIFY BUILDING DEPARTME AT 1, 765-1802 765-1802 8 AM TO 4 PM FOR THE FOLLOWING INSPECTIONS: 1. FOUNDATION - TWO REQUIRED FOR POURED CONCRETE 2. ROUGH - FRAMING & PLUMBING 3. INSULATION 4. FINAL - CONSTRUCTION MUST BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS. COMPLY WITH ALL CODES-OF NEW YORK STATE & TOWN CODES AS REQUIRED AND CONDITIONS OF -SOUROWTOW/dBir INTHOLDIOWN-PIANNING130ARD S OCCUPANCY OR USE IS UNLAWFUL WITHOUT CERTIFICATE OF OCCUPANCY , J AMES J. S TOUT A RCHITECT & Assoc . 2 G REG L ANE EAST NORTHPORT N. Y. 631 - 8 58 9388 i` J '\ I1' C Letter of Certification August 31, 2015 RE: King Residence 2265 Mill Road Peconic, NY 11958 To Whom It May Concern: I, James J. Stout, registered architect NYS license number 021633 would like to submit the following. I have inspected and analyzed the roof structure at the above- mentioned address and have determined the structure and the panel attachment to be adequate to support the new additional load imposed by the proposed solar panel system and is in compliance with 120mph wind design load as per NYS residential code 2010 and ASCE 7-05. The existing 2 x 6 rafters @ 16"o.c. will provide the required support. Thank you for your understanding in this matter. Si er- 9 ; _11 I ,�(�c►w�ll �0RED ARch' ' , tie- J.. Sto , does 3:7-06,‘,c * scA:5,..,74' it' Nom ' ' 1,, X216 33 y0, / \ JOB NO. Io 0 2015—SO670 , -1 a 18" MINIMUM ACCESS PATH ■ PROVIDED ON ADJACENT ROOF ■ M THESE DRAWING HAVE BEEN DESIGNED IN I NOTE: ALL ROOF MOUNTING , O p ■ ACCORDANCE WITH THE (AF & PA) WOOD 1 BRACKETS SHALL BE PROPERLY (4 .\ 1 z 4 ig FRAME CONST. MANUAL OR ONE ND TWO SECURED TO A ROOF RAFTER. rs O . N FAMILY DWELLINGS. �.�. .,� . ._�_ ,. �_«... ��,<, ,s_.._, ,.�tsr..,..,.. 0 > U w L.1 L? rr Q. Q Q ■ II LOCATION OF Un :.:::::::.:::::::•:::� ::❖:::::•:•:;::•:•:::s U SOLAR PANELS • LO THESE DRAWING COMPLY WITH THE THE ACTUAL IN—FIELD ATTACHMENT TO / -� 4 2010 NEW YORK STATE RESIDENTIAL THE ROOF WILL MEET OR EXCEED NYS N QH 14 BUILDING CODE. RESIDENTIAL CODE REQUIREMENTS 00 W ir L) N zW 0 oo • U • o-•-+ W (n 4 co co OUTLINE OF ROOF 0 Z V) • y m ROOF PLAN/PANEL LOCATION z o 10 cn ■ 0) v) a c4 c4 SCALE 1/16"=1'-0" g 2 Er O Il < o EY J U N O O J } z 0 1 Z Z ■il H o LG 300W SOLAR MODULES— (/) _Z C0 0 0_ M FF' 2" X 6" ROOF RAFTER © 16" O.C. >.- a Y N z W y O z ALUMINUM STANDOFF AND L-FOOT 3 0 L; U 0 a Cr) CLIP LAG BOLTED TO RAFTER Q EY 0 a- W 0 y o EL EL O (1. EY U w ° r • z ALUMINUM SUPPORT ! y RAIL BY UNIRAC ��x - 0 p : EXISTING ASPHALT ROOF0 M U SHINGLES (MAX 1 LAYER) ON �_.-~" ¢ W 0 W to U w o 15# BUILDING PAPER ON 1/2" BEDROOM aQ N PLYWOOD SHEATHING W J rn r -- a F— 0 co D ~ _ 4 12 ' ATTIC 0 J .1. u' III ■ �‘����II 111111/_40_ ■ s v • • • i M ii il ROOF CROSS SECTION %,i ,.v1k `� SCALE 1/4"=1'-0" ,hsinimmito I Q_ � ID (O 70 -13> Z / 3,-9. .-93'-9n / / / Z O 19 -H n O I. .' c r � „ �: OC ° p II` : ' II ' fl ,B o -I O Eli _ -'.€11:--, '91,", ,," ,91 ` 91 0O (A -.II ' IL U : , IL - o C CD F 'II : II'.'. -.:II 'II_ D ,11 .,II :il. - . ,,«..11_, � Z II- ` - II 1IL II ' s -H o , .� I: - ., . I, ' 4 -II - ,��`u, IIv: II; ,..II O --‘ .II,- _ -II ,II..-, _II:; to it - ; II II : : . II zm o ' 11 : 91 ' II '. ;II 73D II II,. IIs. ii.. ? U) II . II •,11-,- ,:,W II rrl -II II , ::Fu; N < o CD O K O K p c 2.3 r KC fnN CD 0 O m 0 Tic OC c C) W K _.1 m I -10 �0 ON WZ Z m z D vmi* ° r-c "' z D < Z � co r. o • 0m m rn ›0 m D Z7 * m r rn I C'' D 0) IIc I 0 3 'RAWINGS PREPARED FOR: DRAWN BY: G.V. DATE: 05/28/15 REVISION NO. ���wauurrnseo (� 000 ��.�,•..• •. ifil�, 1414� BUILT WELL PROPOSED SOLAR PANEL INSTALL. 015 Q;: . *. `G>, 1 SOLAR For: KING-NORMAN RESIDENCE 01 felt A: Of; 2265 MILL ROAD + (516)-695-1000 U) ..to„ PECONIC, N.Y. 11958 O ,144 •;;; � ��. 3280 SUNRISE HWY PAGE NO. 0) �q�,,�,�oIF N�`N��,'��`' SUITE 345 PANEL LAYOUTS ' """""��'' WANTAGH NY 11793 A— 3 OF 3 o o aasaaaaaaaasasassaasassasaasaasassasaaaaaasaasaasasaaasasasasasaaaasaasaasaa n ,, 0 0 JAMES J. STOUT ARCHITECT 2 GREG LANE EAST NORTHPORT, NEW YORK (631) 858 9388 I I .1,,, .,, a Life's Good f'!' ::;: ,4, -1,3.-�(,. ,!.,' " � .:,,,,,p.az'.h:i,.�_ .' `, -i.;, s ..;%1'k,,..-:;',1:4;:,:-'A» LG-:ton, :;t'.:n'"2: ', Z;4 1 r t 3 ryS k sa i-ss e dl� tr � �"•, c.�1,i ' C,rvr. ,ww_ ; r,,a'Y . ., �'�'.f �' 1} �-n _.'•'-:":',-'`7,!..-1'': �. r{ 'ti� � �.',':.'-',w1,4'141' v't: �<.,.� ,:g�,.t,, x.'r��(�• ;'Y'.. :J'; ,l r.,., ,z '7• .-}_y',t6'?�' .v.A''.,y ria �v ,�t ,�a�x �` i 'l,Y 3._a] - x- ,;;'11"1.- ice y,;,i,t `11,;�C- A c..: �k''rY ,,v,w .`1r 4 .4x${h ,c- �l�iul .: � .• ittl1j ,4 7c' j' 'rr,;r Y� -_F,;1'# ,�� , l �' �}}�•:' _ � �,,,F a�n`�; i a.s!"; SAX i:. --3.,,t00$414•��+$`"•� �:. 5�.�� ,�`�'�t: r^t .� �„ z t ' t ....;,.-'' r-j 5. n- -,,',-171--ala'- "'4..•..4.. @` 'i j S'� fs.' '' rzr'`* T - 1) 4.--. .3 d4, a r`. >..,i y „�- �.{ t,xs�. u � se :F•`s 'a�"�' d "F J v r a r i o r e' _ y ',:i: .r :�:f `^' :�'' '.W 360,. e`'S'+ •�i p, ,ynr„, x ,+ ii it 4,,.Vs,,J1 ,'``'.'`' .1 ' ' ', t .,. ,. s .4«4�,x.:,,� i 14'*,, r ,, k,13 a� ' x ,., -'4,,es :?', , `'',44.40 .k 4, ? ,+.asy,.,,�+y f` - *...�4. 'wiiP. O., ,€� •• ..w'- se i�5.''44,,:` `,” a-2 s 6;a �1�' ,e1 t y n f 1, s r`+' w7 'r i^ , ,.1_ii,V s Mt'r kf i r. a >y'� 4g-q °I': • r :1 r, r r" "ii.•l�'s',L+��',1, :`, " "t S`-:yy 41X, .. i, a r K� .',„i;:- :,.r�.�i � 't��Z,,�`tl�,,., �°.��"�,',�fa r::iar� �? �t'G�,{v����.;� -,�.�.ti „y�'y' it '4,'•0-41-V1-)',. �,� � a - { � �;. ��,:;;,,t,,, . 1• f '' r ,ta_,x A ,,t ,u4, -I= ? tt sk Lt t �' :- p s e ar m�t, r �,� �r'���� , : � ,� � �x. r�,� .r�^ �' •_,ta-� `; r � ;'r { '•.F� r•,. ,4r:h4µ O�<- <I ZG ,�xi rSa� ?��� b;���t �-��`.� •,i'� , ,,..4.,,e,:.•s.� �ffi .;...:14::,g17:,.., s� v 1.,; qa. .off; 4 fi sow r; tY, s,v, :fi, r •,w E .,.rr nN r f�ar•r- +,• 1,',t0-44t4(' 1 �,,,. to",, y�r,9 } ''', k ` .0, z 'rt�;�=.lt'.._'� � rr, �i`.,t 4,'„•�LC.,..°2"'"�f�., �,r S'`. ="(s,=,.S'7l:. d� < .aw';?'i' ��1„rte;' ren� ��••Ci�:����'���}}��qp]] }Y;• r I' 1 i. , 1 , fi4 LG Electronics, Inc.(Korea Exchange:06657.KS) is l one of the globally leading companies and I 1 technologyinnovator for electronics,information IIII.IU III , �� li illig ' and communication products.The LG Electronics I1111 I�I� I , i7 I ;j il �;: currently employs more than 91,000 people ' ' ' j l f worldwide in 117 companies. In fiscal year 2011, Illlllill1111�1 ; :} 1 ` }1 11 F �1 i 11 { 48.97 billion USD of revenue was achieved. III1IIIOIIJIllI l ` ; 1 ! • fi I I ' '' , g I, I ti , LG is one of the world's largest manufacturers of k +�. � , �ff f l �; I 11' mobile phones,flat screen TVs,air conditioners, IIDIIIIIIDi® tII] ) ! ` washing machines and refrigerators.As a future- oriented company,LG enables others to use 111111/1101 ' 'I j ' i t 1 1 1 � technology consisting of renewable energies. 11111111111®I It i, t LG's high quality solar products are being l ' ii manufactured in LG's leading production facility lIJIIIIIIIIIIIH) E: H 1 +.' ! 1 1 inSouth Korea. t ( , i1DI11111111®1 r� r11 , } dill :', I APPROVED PRODUCT ¢ I i 1Hi _ c us CE ILIIDiL11IIIIIiI , KM 564573 BS EN 61215 f-,_-.:7-77,,, �,_ _ 6 • k I t Photaroltam Modules ' 1. [ } i z Fly,' LG's High Efficient Cell Technology -'1"'''''',9 ® Convenient Installation E. 0== Driven by LG's own N-type technology, LG's high- ( i LG modules are carefully designed to benefit ge>_, efficiency modules will provide customers with installers by allowing quick and easy installations Cell Technology Con,enler4 Cr high economic benefits installat,c, throughout the carrying,grounding,and connecting stages of modules ,,lati ----wit- -5,,,,,:'” an Light and Robust w -= 100% EL Test Completed L . With a weight of just 168 kg,LG modules arerp' All LG modules pass Electroluminescence Light K'erght proven to demonstrate outstanding durability �`�i'�� inspection This EL inspection detects cracks and EL Test against external pressure up to 5400 Pa other imperfections unseen by the naked eye. Reliable Warranties Positive Power Tolerance ;:7- LG stands by its products with the strength of a 3 LG provides rigorous quality testing to solar u=,ear warranty global corporation and sterling warranty policies l 6 p modules to assure customers of the stated power LG offers a 10 year product limited warranty and a P.,t,,, p,,,r outputs of all modules,with a positive nominal 25 year limited linear output warranty. Td'"'"' tolerance starting at 0% Cy ,7� ` '' 4 �' "" '.a $ 1 1 ,„ 4 V''...". ,- ;s:;i "h m �ilF4+`'''»..",..:. [r k+- i ,4 . -.�+.:, . 1 �. z :Ye' ',.. .,.k _*`'`-.11—,t Ag., 4r .' -t'.;° a, y.-,' o h) r r •r ;r x` .i .A y :-=:.. .az a' nr ..„41{,n4,14 � 17�� .° e�1 f 1- S fly 'l�€i. !'� i.• 3 -:4.,s.. aSa� ,t i a.74 teig 4 ix )4 ri,ti' tt=- / v••. cr?,',„ r gZi�/!'Vl �G f-C,`)1 „jv ( p,� 1• ,f-t�iy.. ?-J� ,y _' O 4C Y ,4_,4,,r-.:,4Y� x` 1. Yl ,-.,-;a0--< N e fit, ' # ==',-,4 er to ,, rr r 1 r' �'c 7 IiA-.-' s }- ,t, •� 7* c '`w,t '��`,z41d;'.t:; *�'r--. � 1��ee'-y -s. ) t � i�+8, i ' S .4==, a 4qt,r; 'h z, p 2..:4,- e ,r., `l.0 ;,.,h1 ' .y ss,1 .41,,, ,i,..1..,,,,,„:„, •,cc`"p < �' ; ,s fit€ a ;.',, ;� est 'A.. 1): A , e 4'-' ;...,`il 8„ ' '' ' r, a I' rt .k � �'.�`� ���L'-��`�'*` ���,!t)�t• t�u'r�;• u?fr m. `�: "`�tcc• '`�,�7 as. `*< a s i'�0 !6' r9r +k ', r 3� > .i, i� :�`,`3 '�r; r'bty'"'�U �fj Fe y"'.lipk. �,'- y`, S:k'.;yam;g^'r:;-''�[ 7,'F- ;. ,^v, f - LG 3 00N-654.®5.,-,-,c :N�s.,,,, ,rt �y; - a,rq,.', + 7,ex,, iv-,{`-gz- l sv .,.,n E-, . 4�k �^a+iti z, J,,;,. , �a3,?,,:`, 'x �,,r ,P v - & s,,.x,=,, , ,r;,=,, ,,; ) 4r - -,i.24.4., +� .5 ;i ';�. •. ,ri .,' -,4,,,..'.- s :i i:.,.„1-,,,r,! B. ® Mechanical Properties ®Electrical Properties(STC*) • Cells 6x10 300W Cell vendor LG MPP voltage(Vmpp) 32 0 Cell type Monocrystalline MPP current(Impp) 946 Cell dimensions 156 x 156 mm/6 x 6 in • • • •• #of busbar 3 Open circuit voltage(Voc) 39 5 Dimensions(L x W x H) 1640 x 1000 x 35 mm Short circuit current(Isc) 1005 64 57 x 39.37 x 1 38 in Module efficiency(%) 18 3 Static snow load 5400 Pa/113 psf Operating temperature(°C) -40-+90 • Static wind load 2400 Pa/50 psf -__ _ Maximum system voltage(V) 600(UL),1000(IEC) Weight , • 16 8±0.5 kg/36 96±11 lb A_ Maximum series fuse rating(A) 20 Connector type MC4 connector IP 67 Junction box IP 67 with 3 bypass diodes Power tolerance(%) 0-+3 ------`----^ •STC(Standard Test Condition)irradiance 1000 Whir?,module temperature 25°C,AM 15 Length of cables 2 x 1000 mm/2 x 39 37 in •The nameplate power output is measured and determined by LG Electronics at its sole and absolute discretion Glass High transmission tempered glass Frame Anodized aluminum — ®Electrical Properties(NOCT9) 300W 0 Certifications and Warranty Maximum power(Pmpp) 221 • Certifications IEC 61215,IEC 61730-1/-2,UL 1703, MPP voltage(Vmpp) 29 3 ISO 9001,IEC 61701 MPP current(Impp) - 755 Product warranty 10 years -• • •• •.... • • • ••.. Output warranty of Pmax ----"----' Open circuit voltage(Voc) 36.5 (measurement Tolerance t 3%) Linear warranty' Short circuit current(Isc) 807 •.01st year 97%,2)After 2nd year 07%annual degradation,3)80 2%for 25 years Efficiency reduction (from 1000 Wire to 200 W/m9 4 5% •NOCT(Nominal Operating Cell Temperature)Irradiance 800 W/m°,ambient temperature 20°C, ®Temperature Coefficients wind speed 1 m/s NOCT 45±2°C 10/040 10/0 ao ® Pmpp 0.42%/°C^-� Dimensions(mm/in) -- Voc _0.31%/•C-- — — g Isc 003%/°C & M [; ® Characteristic Curves 1000/39.37 aoitm 22/067 65.40(x Ha) Dram hol..i4a.1 Long side frame Short side frame a 70 1000W 4.016 oYemi •.• `c 9 Dr.h,hoi.•i4ea) (aat•nee between moun6n9 hoi..l 931071 L_ J __ 12-04wounding 1,01112.41,01112.4 e-ee OR .•1 Mounting hWie•a) /,.`, / 10°0/39.37 Cable length \ 5 10 15 20 25 30 35 4q/oltage(V) 915/006 140 _ Dena x 1 4 g 720 I 0/016 ISC C e 100 h r ifti 80 Voc o.nnr -• 944/3717 j 09/0.31 so Pmax midl Of- 40 II ,..ogioliuiiii 1 ng D• 2 111111111IIIIIIIIIIIIIIIII 20 J � 3, 0 36/130 -40 -25 0 25 50 75 90 Temperature(•C) •The distance between the center of the mounting/grounding holes North Amenca Solar Business Team Product specifications are subject to change without notice E -.f CILG Electronics U S A Inc "LG Life's Good"is a registrated trademark of LG Corp �,� 1000 Sylvan Ave,Englewood Cliffs, All other trademarks are the property of their respective owners y�,•,( i NJ 07632 DS N 60 C US F EN 30520 •• ;; TO Copyright©2013 LG Electronics All nghts reserved i Life's Good Contach Ig solar@Ige corn www Igsolarusa corn 05/01/2013 • • Enphase®Microinverters Enphase® ` 250 0 „. LIL ' t ra �G,,. ._...._ •„x :.+ _ .__,. _.....,wwira�.r•.'+.+:«•.a.= ...a.w`ww.wsn ..+er.w.wr..v+±r• The Enphase® M250 Microinverter delivers increased energy harvest and reduces design and installation complexity with,its all-AC approach. With the M250, the DC circuit is isolated and insulated from ground, so no Ground Electrode Conductor(GEC) is required for the microinverter.This further simplifies installation, enhances safety, and saves on labor and materials costs. The Enphase M250 integrates seamlessly with the Engage®Cable, the Envoy® Communications Gateway", and Enlighten®, Enphase's monitoring and analysis software. PRODUCTIVE SIMPLE RELIA :=` LE -Optimized for higher-power - No GEC needed for microinverter - 4th-generation product modules - No DC design or string calculation - More than 1 million hours of testing - Maximizes energy production required and 3 million units shipped - Minimizes impact of shading, - Easy installation with Engage - Industry-leading warranty, up to 25 dust, and debris Cable years [e] enphase® E N E R G Y c us • I .Ii II Enphase®M250 Microinverter//DATA INPUT DATA (DC) M250-60-2LL-S22/S23/S24 Recommended input power(STC) 210-300 W Maximum input DC voltage 48 V Peak power tracking voltage 27 V-39 V Operating range 16 V-48 V Min/Max start voltage 22 V/48 V Max DC short circuit current 15 A Max input current 9.8 A OUTPUT DATA(AC) @208 VAC @240 VAC Peak output power 250 W 250 W Rated(continuous)output power 240 W 240 W Nominal output current 1.15 A(A rms at nominal duration) 1.0 A(A rms at nominal duration) Nominal voltage/range 208 V/183-229 V 240 V/211-264 V Nominal frequency/range 60.0/57-61 Hz 60.0/57-61 Hz Extended frequency range* 57-62.5 Hz 57-62.5 Hz Power factor >0.95 >0.95 Maximum units per 20 A branch circuit 24(three phase) 16(single phase) Maximum output fault current 850 mA rms for 6 cycles 850 mA rms for 6 cycles EFFICIENCY CEC weighted efficiency,240 VAC 96.5% CEC weighted efficiency,208 VAC 96.0% Peak inverter efficiency 96.5% Static MPPT efficiency(weighted,reference EN50530) 99.4% Night time power consumption 65 mW max MECHANICAL DATA Ambient temperature range -40°C to+65°C Operating temperature range(internal) -40°C to+85°C Dimensions(WxHxD) 171 mm x 173 mm x 30 mm(without mounting bracket) Weight 2.0 kg Cooling Natural convection-No fans Enclosure environmental rating Outdoor-NEMA 6 FEATURES Compatibility Compatible with 60-cell PV modules. Communication Power line Integrated ground The DC circuit meets the requirements for ungrounded PV arrays in NEC 690.35. Equipment ground is provided in the Engage Cable. No additional GEC or ground is required. Monitoring Free lifetime monitoring via Enlighten software Compliance UL1741/IEEE1547, FCC Part 15 Class B,CAN/CSA-C22.2 NO.0-M91, 0.4-04,and 107.1-01 *Frequency ranges can be extended beyond nominal if required by the utility To learn more about Enphase Microinverter technology, enphase® visit enphase.com [9ienphase® " JE N ERGY 0 2013 Enphase Energy.All rights reserved.All trademarks or brands in this document are registered by their respective owner. - k ArAt: IP) � N 0 /i i/ I-0.75--I 000Nin 00 �,� SolarMount - ©2008 UNIRAC, INC. �+ ® s 1411 BROADWAY BLVD NE Standard Fall ALBUQUERQUE, NM 87102 USA PHONE 505.242.6411 UNIRAC.COM UNIRAC-300001