39619-Z
!f Town of Southold 1/13/2016 P.O. Box 1179 53095 Main Rd oT°a ;,doSouthold,New York 11971 # CERTIFICATE OF OCCUPANCY • No: 38041 Date: - 1/13/2016 THIS CERTIFIES that the building ADDITION/ALTERATION Location of Property: 170 Moores Ln, Greenport SCTM#: 473889 Sec/Block/Lot: 45.-7-3 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 2/11/2015 pursuant to which Building Permit No. 39619 dated 3/27/2015 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: alterations and additions, including handicap ramp, to an existing commercial building as applied for per ZBA#6801, dated 11/20/2014. The certificate is issued to 170 Moore's Lane Rlty Crp of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL • ELECTRICAL CERTIFICATE NO. 39619 1/13/2016 PLUMBERS CERTIFICATION DATED 11/18/2015 / Joseph Whitecavage War • •th►,rize• .ignat TOWN OF SOUTHOLD x� '. BUILDING DEPARTMENT TOWN CLERK'S OFFICE V!0:, ,' SOUTHOLD, NY * ;•' BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 39619 Date: 3/27/2015 Permission is hereby granted to: 170 Moore's Lane Rlty Crp PO BOX 826 ' Shelter Island, NY 11964 To: Additions and alterations to an existing commercial building as applied for, per ZBA and Planning. At premises located at: 170 Moores Ln, Greenport SCTM # 473889 Sec/Block/Lot# 45.-7-3 Pursuant to application dated 2/11/2015 and approved by the Building Inspector. To expire on 9/25/2016. Fees: CO -COMMERCIAL $50.00 COMMERCIAL ADDITION/ALTERATION $706.00 Total: $756.00 1 Buildi g Inspector rA Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings, property lines,streets,and unusual natural or topographic features. 2. Final Approval from Health Dept.of water supply and sewerage-disposal (S-9 form). 3. Approval of'eleotrical installation from Board of Fire,Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead. 5. Commercial building, industrial building,multiple residences and similar buildings and installations,a certificate of Code Compliance from:architect or engineer responsible for the building. 6. Submit'Planning Board Approvaloof completed site plan requirements. B. For existing buildings(prior`to April 9, 1957)non-conforming uses,or buildings and "pre-existing" land uses: 1. Accurate survey of property showing all property lines,streets,building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees I. Certificate of Occupancy -New dwelling$50.00,Additions to dwelling$50.00, Alterations to dwelling$50.00, Swimming pool $50.00, Accessory building$50.00, Additions to accessory building$50 00, Businesses$50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of-Occupancy-$.25 4. Updated Certificate of Occupancy - $50.00 5. Temporary Certificate of.Occupancy - Residential $15 00, Commercial $15.00 Date. %•Z .49 /j New Construction: Old or Pre-existing Building: (check one) Location of Property: /70 /t—look—Gr G.4-r7-�_. n_e_e_-,tio0VA 171 /1 5-`fry House No. Street / Hamlet Owner or Owners of Property: 7 i Suffolk County Tax Map No 1000,'Section -r Block 7 Lot Subdivision ��, p • - Filed Map. Lot: ! Permit No. 3 (.( ! Date of Permit. Applicant: /�G1-7/S-C-C—(tel-ir-u_L7-7SIA--- Health Dept.Approval: Underwriters Approval: Planning Board Approval: / Request for: Temporary Certificate- Final Certificate: ✓ (check one) Fee Submitted: $ .o' t?01 111, �Applican •nature �/ 4i SO(Jt' - Town Hall Annex t�� ~O l0 : Telephone(631)765-1802 54375 Main Road * * t Fax (631)765-9502 P.O.Box 1179 : G ki Southold,NY 11971-0959 '^eOly .0,,�1� roger.richertCa�town.southold.ny.us % COMA° ° ... .• � BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION Issued To. Jernick Address: 170 Moores Lane City' Greenport St: New York Zip: 11944 Building Permit* 39619 Section: 45 Block. 7 Lot: 3 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA. RJ Corazzini Electric License No: 33419-ME SITE DETAILS Office Use Only Residential Indoor X Basement Service Only Commerical X Outdoor X 1st Floor X Pool New X Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph 200A Heat Duplec Recpt 29 Ceiling Fixtures HID Fixtures Service 3 ph Hot Water GFCI Recpt 4 Wall Fixtures 6 Smoke Detectors Main Panel 200A A/C Condenser 1 Single Recpt Recessed Fixtures 23 CO Detectors Sub Panel A/C Blower 1 Range Recpt Fluorescent Fixture Pumps Transformer Appliances Dryer Recpt Emergency Fixtures Time Clocks Disconnect 200A Switches 15 Twist Lock Exit Fixtures TVSS Other Equipment: 1-Exhaust Fan Notes: Inspector Signature: RDate: January 13, 2016 Electrical 81 Compliance Form.xls Town Hall Annex ; ~ . Telephone(631).765-1802 • ' 54375 Main Road iiNg .. • • ; Fax(631).765.9502 P.O.Box 1179 a G • • . Q ,r, Southold,New York 11971-0959 : Q4, -. ) tb i Urr IY t 1, rlrr B UII.DIN I DEPARTMENT TOWN OF SOUTHOLD L., L 11 NOV 1 9 2015 — � .::,/) �� CERTIFICATION Rli); 1.EP IP\ ;,r SCI iGioLr Date: ///(5/..j5 . Building Permit No. 3 9 6- / Owner: /70 O o K_.r Lam-? /2 / i 6 - (Please print) 1 Plumber: .SOSP71) AA , CI✓Gi �• / (Please.print) I certify'that the solder used'in the water supply system contains less than 2/10 of 1% • lead. / �...,,, - ._ - (Plumbers Signature). Sworn to before me this /O , day of A , 20 AC Notary Public, County NotaryPublic; to dM• i •alt 4831950,Suffolk County q ion- res May 31,2011 , �Of SOS fo ly A Jos r TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ F NDATION 1ST [ ] ROUGH PLUMBING [ FOUNDATION 2ND [ ] INSULATION [ ] FRAMING / STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] CAULKING REMARKS: .c.„, _ . :3 •Cre4Trp • DATE INSPECTOR 1' „pF SOUIyOIa'; TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION ' [ ] FOUN ION 1ST [ ] ROUGH PLUMBING [ ] F NDATION 2ND [ ] INSULATION [ FRAMING / STRAPPING [ ] FINAL [ ] FIREPLACE-A CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] ULKING REMARKS: J / DATE ([l ( INSPECTOR y.tr., 919 SOUjyolo,` N ie Com* '0I TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [Yr ROUGH PLUMBING [ ] FOUNDATION 2ND [ INSULATION [ ] FRAMING / STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY - [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] CAULKING REMARKS: `3 r /-.4419 DATE. 07 INSPECTOR -14' ( (t oF souryo� * ,z1€G Q•� recourrti*to''� TOWN OF SOUTHOLD BUILDING`DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [1J KO GH PLUMBING [ ] FOUNDATION 2ND [ vriNSULATION [ ] FRAMING / STRAPPING [ ] FINAL [- ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATI N [ ] CAULKING REMARKS: ` Oe • DATE 0 7/°6/6 INSPECTOR 9/144" e_ -------------- vi Uly TOWN OF • HOLD B" ' ING DEPT. 765-1802 1 - ECTIO [ ] FOUNDATION- 1 ST [ ] • • - PLUMBING [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMI TRAPPING [ ] FINAL [ ] F PLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] CAULKING REMARKS: 614- .. � e/t &L/41,—,... 51 Arr 41' CkIJX&geo4--Z 4r- c ) 6)0 d#/2-624/- e7 DATE / I INSPECTOR pf SOUr�-., �J i � 124/0 TOWN OF SOUTHOLD BUILDING DEPT. 765.1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY ikIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) REMARKS: AJO E)(TUSe®/U ?OJS 00 1;-• nr- ar- Id/A" ge- his • _ rsC C 0 DATE 11" I7 ! INSPECTOR IF Bunch, Connie From: Richter, Jamie Sent: Thursday, December 17, 2015 7:15 AM To: Bunch, Connie Subject: RE: 1000-45-7-3 Connie • The drainage for this site has been inspected and approved by my office. Sorry for the delay in getting you this report, I was out of the office yesterday. Jamie yonseo. a. , James A. Richter, R.A. Stormwater Manager Office of the Engineer Town of Southold, New York Stormwater Management Control Plan Website: http://www.southoldtownny.gov/index.aspx?nid=195 Office: 631-765-1560 Cell: 631-926-9430 CONFIDENTIALITY NOTICE: This communication with its contents may contain confidential and/or legally privileged information It is solely for the use of the intended recipient(s) Unauthorized interception,review, use or disclosure is prohibited and may violate applicable laws including the Electronic Communications Privacy Act. If you are not the intended recipient, please contact the sender and destroy all copies of the communication From: Bunch, Connie Sent: Tuesday, December 15, 2015 1:53 PM To: Richter, Jamie Subject: 1000-45-7-3 Do you need to inspect for final storm water approval on this building? We have final Planning Board approval and I'm ready to type the C/O. Thanks Connie 1 • • tt r . \, FIELD IN•SPECTIQN/MOR[' DATE , , . CO►ii c.. . 5 . .4' .7.-rir ,/6.-:). iP71"911PIWO/"‹ - - .q,„:, FOUNDATION(1ST) • • � trJ `Ifs" FOUNDATION(2ND) ; z � 0777 ••: : . ,--..--)' . . , •-g ; H . g ROUGH FRA IZZG& 07 o ri�/e-3.0 � _ / - , "i`, - • • PLUMBINGip lb 4::-17;a7 - • ' -. . . 1 . lik• • Amin . p ' A9 1,. 14'4- . . ' . =- J .#0-d) . 1 0 $ J, - . 1.:6y . , . INSULATION PER N.Y. Q �.. • moi- STATE ENERGY CORE , . A41, . �-0� •��� .. / _.. r :r ! -IP, s . . - ate-'( _ I . • - . - . if FINAL ° . rte✓ . 1 ' (ma �� N-�/. • • F t . ItAl" „_..— . • if I .,,,,,,s- '. .- .. - . .6o-, ....cD. . 4="6 -L_____ .- . .. • . g ° • C: r431 Lc-1.3 --_i).'i-','s c) TA gec:,_, (3 P'' • 119.3q4 /1 4' • 9 4 • sMJ 8 S . f . In n(\.); ouy4 u - )1 — ,C-- .01,---6i'�P-" /?&q/Pk -e (rt -W9 . . . . ®4.. _rig e-0. • r •. -- .� 4. } -► 1-I.5. 7-Tel/rt-e./ c-e. . 0� t ) Q .�r/AJ 6frI k-P� g mg . Tr M i__ .TO,-WN OF SOUTHOLD' BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or'need the following,before applying? TOWN HALL Board of Health SOUTHOLD,NY 11971 ' - 4 sets of Building Plans ✓ TEL: (631)765-1802 ' .- , Planning Board approval FAX:'(631) 765-9502 . 2 . 6 I - Survey e • .-r..• SoutholdTown.NorthFork.net- ' PERMIT N I J _ Check #/5-ft' ' Q Septic Form D E N.Y.S.D.E.C. Trustees FloodPermit Permit Examined ,20 FEB 1 1 2015 Storm-Water Assessment Form Contact: LL, /Go-�n Approved ,20 l BLDG.DEPT Mail to: 117C rt.C.11%)'•— aF SOUTHOLD 0 �UK 33',8 J�df Disapproved ale Phone: L17-7 -0? -77 //q,, Expiration ,20 i Building Inspector APPLICATION FOR BUILDING PERMIT ' Date -J4-n.Gt.4.r�'/2- , 20 /i_5 INSTRUCTIONS • a.This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans, accurate plot-plan to scale. Fee according to schedule. b:Plot plan showing location oflot and of buildings-on premises, relationship-to adjoining premises or.public streets or - areas,and waterways. c.The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize, in writing,the extension of the permit for an addition six months.Thereafter,a new permit shall be required. APPLICATION IS HEREBY MADE to the building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York, and other applicable Laws, Ordinances or Regulations, for the construction of buildings, additions,or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances, building code, housing code,and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. ?is- (AA-/ u ct,.6yt✓ (Signature of applicant or name,if a corporation) Po ' ' 3 91 , C,v7-e- )0�-r' /7 //(Ivy (Mailing address of applicant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder Name of owner of premises / I _ f 0 4':✓� 5 Z-4141-<- 1Re-�L- , It) C'v - (As on the tax roll or latest deed) - If applicant is a corpQratio signature of duly authorized officer - G ' 1 9- �f c = /�ic S/�2i/ - (Name and title of corporate dffic r) Builders License No. Plumbers License No. Electricians License No. - Other Trade's License No. 1. Location of land on which proposed work will be done: /70 /nP/r 5' I.g z_- CVt'eitpoe House Number Street Hamlet - County Tax Map No. 1000 Section Block 7 Lot Subdivision Filed Map No. Lot , • 2. State existing use and occupancy of premises and intended use and occupancy of proposed constru on: a. Existing use and occupancy , i —? i3�C 'i/4in> `5,71-0-y- /o t -t- b. Intended use and occupancy -Zt.v 4 .LLL 71-; " L )'?.-C ° 3. Nature of work(check which applicable): New Building Addition ✓ Alteration . Repair Removal Demolition Other Work • (Description) 4. Estimated Cost Fee (To be paid on filing this application) 5. If dwelling, number of dwelling units f'1 f A-- Number of dwelling units on each floor /1/4-- If garage, number of cars pl/A-- 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. 6 � c-10 L-�-- 7. Dimensions of existing structures, if any: Front /.Z`f. 4`' Rear /./J74. Depth /•Z- 2 Height --0 / Number of Stories Dimensions of same structure with alterations or additions: Front Rear /-1-`1- Depth -z`'-Depth y -7 . y Height )--a Number of Stories 8, Dimensions of entire new construction: Front /%' Rear / �/ - Depth t' Height / 5 Number of Stories / 9. Size of lot: Front /3`"^ Rear / 4 S) Depth 3 0 S-, 7) 10. Date of Purchase Name of Former Owner 11. Zone or use district in which premises are situated �J 12. Does proposed construction violate any zoning law, ordinance or regulation?YES NO 13. Will lot be re-graded? YES , NO Will excess fill be removed from premises? YES NO 14. Names of Owner of premises/76/-/ocre 5/4 -11LAddr'ess%o 436 -2-6 Phone i\l y 77-6 fel Name of Architect Address Phone No Name of Contractor /Z s c i (.. &.C/ .c.h;Itddress Pu'l< F Phone No. i f 7 7-0 y y 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO * IF YES, SOUTHOLD TOWN TRUSTEES & D.E.C. PERMITS MAY BE .EQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO �,/ * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey, to scales with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on vey. 18. Are there any covenants and restrictions with respect to this property? * YES NO * IF YES, PROVIDE A COPY. STATE OF NEW YORK) r �S)S: COUNT//Y0 VUR� C-Vr !n being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing cos ntr'act)above named, (S)He is the U-4-4-&741// T (Contractor, Agent,Corpo ate Officer,etc.) of said owner or owners,and is duly authorized to perform-or have performed the said work and to make and file this application; that all statements contained in this application are truecto the best 0'0A s knowledge and belief; and that the work will be performed in the tanner set forth in the application filed therewith. - Sworn to efore me thi M"--clay of f_,A__ i/2 . 20 1 — No . Pub is Signature o 71.1Wr t, CYNTHIA M.CUSATI Notary Public,State of New York - No.01CU6100507 Qualified in Suffolk County Commission Expires Oct 201 � v ' BOARD MEMBERS ,.,' :_ Southold Town Hall Leslie Kanes Weisman,Chairperson OF SOU, 53095 Main Road•P.O.Box 1179 •o 4� y0 - / O ! Southold,NY 11971-0959 Eric Dantes * *; Office Location: Gerard P.Goehringer ; cr, � Town Annex/First Floor,Capital One Bank George Horning . . ,�� 54375 Main Road(at Youngs Avenue) Kenneth Schneider _l''Coutirt,0.••i•� Southold,NY 11971 ,,0 , http://southoldtown.northfork.net ZONING BOARD OF APPEALS TOWN OF SOUTHOLD Tel.(631) 765-1809•Fax (631)765-9064 FINDINGS,DELIBERATIONS AND DETERMINATION MEETING OF NOVEMBER 20,2014 ZBA FILE: 6801 NAME OF APPLICANT: 170 Moore's Lane Realty Corp.(Ratsey Construction) PROPERTY LOCATION: 170 Moores Lane, Greenport,NY SCTM#1000-45-7-3 SEQRA DETERMINATION: The Zoning Board of Appeals has visited the property under consideration in this application and determines that this review falls under the Type II category of the State's List of Actions, without further steps under SEQRA. SUFFOLK COUNTY ADMINISTRATIVE CODE: This application was referred as required under the Suffolk County Administrative Code Sections A 14-14 to 23, and the Suffolk County Department of Planning issued its reply dated October 30, 2014 stating that this application is considered a matter for local determination as there appears to be no significant county-wide or inter-community impact. LWRP DETERMINATION: The relief, permit, or interpretation requested in this application is listed under the Minor Actions exempt list and is not subject to review under Chapter 268. PROPERTY FACTS/DESCRIPTION: Subject Parcel is located in a B Zone and is improved with a 16,061 sq. ft. one story metal building. The parcel has 170.33 feet of frontage on Moore's Lane, 305.73 feet on the southerly side, 302.39 feet on the northerly side, and 169.49 feet on the easterly side. As shown on the survey provided by Nathan Taft Corwin, III,Land Surveyor, dated January 28, 2014 last revised October 14,2014. BASIS OF APPLICATION: Request for Variances from Article XI, Sections 280-50A and 280-49 and the Building Inspector's May 30, 2014, renewed July 30, 2014, Amended October 6, 2014 Notice of Disapproval based on an application for building permit for addition and alterations to an existing commercial building, at; 1) less than the code required front yard setback of 100 feet, 2) more than the code permitted maximum lot coverage of 30%. RELIEF REQUESTED: The applicant requests variances to construct a one story office addition to the front of the existing metal building with a front yard setback of 26.6' where the code requires 100 feet and lot coverage of 33.4%where the code allows a maximum of 30% lot coverage. ADDITIONAL INFORMATION: This parcel has had several variance applications before the Zoning Board. File # 353 in 1961 granted temporary amusement use. File #399 in 1961 granted to construct a bowling alley. In 1962 file #434 granted a reduced front yard setback for a cooling tower. Under file #653 in 1964 denied permission to paint the words BOWL and RESTAURANT on the southern roof. File#1513 in 1972 granted permission to rebuild a non-conforming business building. And lastly, granted permission to reduce front and side yard setbacks to construct additions under file#2366 in 1977. Page 2 of -November 20,2014 ZBA#6801—170 Moore's Lane Realty Corp. SCTM#1000-45-7-3 • FINDINGS OF FACT/REASONS FOR BOARD ACTION: The Zoning Board of Appeals held a public hearing on this application on November 6,2014 at which time written and oral evidence were presented. Based upon all testimony, documentation,personal inspection of the property and surrounding neighborhood, and other evidence,the Zoning Board finds the following facts to be true and relevant and makes the following findings: 1. Town Law §267-b(3)(b)(1). Grant of the variances will not produce an undesirable change in the character of the neighborhood or a detriment to nearby properties. The property is zoned business and is surrounded by other businesses, a school, park, Public Utility Company and a few residential properties. The property has historically been used for business. 2. Town Law §267-b(3)(b)(2). The benefit sought by the applicant cannot be achieved by some method, feasible for the applicant to pursue, other than an area variance. This is because of the size of the building which has been in existence for more than 40 years, and is currently used as a moving and storage company which is a conforming use in the B zone. The present applicant wishes to construct an attached office to a portion of the front of the building. Any other location for the proposed office would either obstruct circulation around two sides of the building and would still require a variance, or if added to the rear would reduce parking flow for vehicles 3. Town Law §267-b(3)(b)(3). The variance granted herein is not mathematically substantial, representing 11% relief from the code for the lot coverage. The variance granted herein for the front yard setback is mathematically substantial, representing 73% relief from the code. However, the applicant submitted documentation showing the average front yard setback for the road to be 24.1 feet and the proposed addition will be setback further than the average. - 4. Town Law §267-b(3)(b)(4) No evidence has been submitted to suggest that a variance in this residential community will not have an adverse impact on the physical or environmental conditions in the neighborhood. The applicant must comply with Chapter 236 of the Town's Storm Water Management Code 5. Town Law §267-b(3)(b)(5). The difficulty has been self-created. The applicant purchased the parcel after the Zoning Code was in effect and it is presumed that the applicant had actual or constructive knowledge of the limitations on the use of the parcel under the Zoning Code in effect prior to or at the time of purchase. 6. Town Law §267-b. Grant of the requested relief is the minimum action necessary and adequate to enable the applicant to enjoy the benefit of an office addition while preserving and protecting the character of the neighborhood and the health, safety and welfare of the community. RESOLUTION OF THE BOARD: In considering all of the above factors and applying the balancing test under New York Town Law 267-B, motion was offered by Member Goehringer, seconded by Member Weisman (Chairperson), and duly carried, to GRANT, the variances as applied for, and shown on the survey prepared by Nathan Taft Corwin, III Land Surveyor dated January 28, 2014 last revised October 14, 2014. Any deviation from the survey, site plan and/or architectural drawings cited in this decision will result in delays and/or a possible denial by the Building Department of a building permit, and may require a new application and public hearing before the Zoning Board of Appeals. Any deviation from the varrance(s)granted herein as shown on the architectural drawings, site plan and/or survey cited above, such as alterations, extensions, or demolitions, are not authorized under this application when Page 3 of 3-November 20,2014 ZBA#6801—170 Moore's Lane Realty Corp. SCTM#1000-45-7-3 involving nonconformities under the zoning code. This action does not authorize or condone any current or future use, setback or other feature of the subject property that may violate the Zoning Code, other than such uses, setbacks and other features as are expressly addressed in this action. The Board reserves the right to substitute a similar design that is de minimis in nature for an alteration that does not increase the degree of nonconformity Vote of the Board: Ayes: Members Weisman (Chairperson), Schneider, Horning, Goehringer, Dantes. This Resolution was duly adopted(5-0). rikxed- 72.e4yri-o--v.L- Leslie Kanes eisman, Chairperson Approved for filing `7 //2014 ��,�� MAILING ADDRESS: PLANNING BOARD MEMBERS �� le �F SO(// P.O. Box 1179 DONALD J.WILCENSHIe��I�QV`� ' y(3 ` Southold, NY 11971 Chair OFFICE LOCATION: WILLIAM J.CREMERS Town Hall Annex PIERCE RAFFERTY �; �O „, 54375 State Route 25 JAMES H.RICH III any -- a.1 (cor. Main Rd. &Youngs Ave.) MARTIN H.SIDOR -4 CQ11My ,i� Southold, NY Telephone: 631 765-1938 • www.southoldtownny.gov PLANNING BOARD OFFICE TOWN OF SOUTHOLD February 10, 2015 ID E din ;_ Mr. Colin Ratsey I { C P.O. Box 398I i FEB 1 0 2015 i v` Greenport, NY 11944 u u Re: Approval - Proposed Site Plan for 170 Moores Lane Realty Co p. Roc.KM- 170 Moores Lane, ±130' n/w/o Moores Lane & NYS Rt. 25, Gree •. SCTM#1000-45-7-3 Zoning District: LI Dear Mr. Ratsey: The following resolutions were adopted at a meeting of the Southold Town Planning Board on - — February9,-20-15: ---------- - -- ---- - -------WHEREAS,-this-Site-Plan-is for-a-proposed-60'x 19'(1-140-sq-ft-)-offce-addition_to_an existing 129' x 125' warehouse building on 1.2 acres in the Light Industrial Zoning District, Greenport; and WHEREAS, on-September 30, 2014, the agent-for-the applicant, Colin Ratsey, submitted an application for Site Plan review; and WHEREAS, on October 1, 2014, a revised Notice of Disapproval was issued by the Building Department noting the proposed relocation of the office addition, effectively re-classifying the required Variances for the application; and WHEREAS, on October 15, 2014, the agent for the applicant, Colin Ratsey, submitted revised Site Plans for review; and WHEREAS, at a Work Session held on October 20, 2014, the Planning Board formally accepted the application for review with revisions and information to be submitted immediately; and WHEREAS, the Southold Town Planning Board, pursuant to State Environmental Quality Review Act (SEQRA) 6 NYCRR, Part 617.5 (c), has determined that the proposed action is a Type II Action as it falls within the following description for 6 NYCRR, Part 617.5(c)(7): construction or expansion of a primary or accessory/appurtenant, non-residential structure or 170 Moore's Lane [2] February 10, 2015 facility involving less than 4,000 square feet of gross floor area and not involving a change in • zoning or a use variance and consistent with local land use controls, but not radio communication or microwave transmission facilities. The action is to construct a 1,140 sq. ft. building in the location of an existing concrete pad; and WHEREAS, on November 6, 2014, the agent for the applicant, Colin Ratsey, submitted the remaining application materials to the Planning Board; and WHEREAS, on November 14, 2014, the Planning Board, pursuant to Southold Town Code §280-131 C., distributed the application to the required agencies for their comments; and WHEREAS, on November 20, 2014, the Zoning Board of Appeals issued a decision for File #6801, granting a non-conforming front yard variance of 26'6" and a lot coverage percentage of 33.4% (LI = 30% max) with no conditions; and WHEREAS, on December 10, 2014, the Southold Town Engineering Inspector reviewed the above-referenced application and determined that the proposed drainage meets the minimum requirements of Chapter 236 for Storm Water Management and required revisions to the Site Plan so the drainage calculations and drainage depictions on the Site Plan are consistent; and WHEREAS, on December 15, 2014, a public hearing was held and closed for the above- referenced application; and WHEREAS,—on-December—l8-2014,—the-Southold Town-Fire-Inspector_reviewed_the proposed Site Plan and determined that there was adequate fire protection and emergency -- ---- — WHEREAS, on January 1, 2015, the Town of Southold LWRP Coordinator reviewed the above-referenced project and determined the proposed project to be consistent with Southold Town-LWRP-Policies-with recommendations for additionallandscaping_and the practices of on-site water quality controls; and WHEREAS, on January 21, 2015, the agent to the applicant, Colin Ratsey, submitted revised Site Plans sufficiently including the revisions required by the Southold Town Engineering Inspector and the Planning Board; and WHEREAS, pursuant to §280-133 C, the Planning Board has the discretion to waive any or all of the requirements of§ 280-133 by resolution at a duly noticed public meeting, for those applications involving modifications to existing structures with no substantial change to the existing footprint, where the Planning Board determines that such modifications or any change in use will not require significant changes to existing major site design features, as well as applications involving uses strictly related to agriculture (but excepting retail winery operations), if it determines such requirements are not necessary to protect and maintain the public health, safety, or welfare and to further the objectives set forth in §280-129. The Planning Board has found that requiring the entire set of Site Plan Application requirements for this site is not necessary to further the objectives set forth in Town Code §280-129 and maintain public health, safety, and welfare for the following reasons: the application is for a small office.addition (1,140 sq. ft.) being placed on an existing concrete pad; the office 170 Moore's Lane [3] February 10, 2015 addition will not be open to the public and will not increase the amount of employees on site; and WHEREAS, the Southold Town Planning Board, pursuant to Southold Town Code §280-131 B (5), has the discretion to vary or waive the parking requirements for Site Plan Applications where doing so would not have a detrimental effect on the public health, safety or general welfare, and will not have the effect of nullifying the intent and provision of the Site Plan requirements chapter of the Town Code. The Planning Board has found that this application is eligible for a waiver of parking requirements because the office space and associated office employees are being moved from inside the existing building to this new location to make more storage space inside the existing building; and WHEREAS, at their Work Session on January 28, 2014, the Southold Town Planning Board determined that all applicable requirements of the Site Plan Regulations, Article XXIV, §280 — 130 Site Plan Approval of the Town of Southold, have been met; and WHEREAS, on February 6, 2015, the Southold Town Chief Building Inspector reviewed and certified the proposed warehousing use as a permitted use in the Light Industrial Zoning District pursuant to ZBA File #6801; therefore, be it RESOLVED, that the Southold Town Planning Board hereby waives the following Site Plan Application requirements: §280-133 B(1)(f), B(1)(g) and B(1)(j); B(2)(d); and be it further RESOLVED, that the Southold Town Planning Board hereby waives the parking -------requirements-as-detailed-above;and-be-it-further._ --_— _ RESOLVED, that the Southold Town Planning Board has determined that this proposed action is a Type II Action and not subject to review under SEQRA; and be it further RESOLVED, that the Southold Town Planning Board has determined that this proposed action is consistent with the policies of the Town of Southold Local Waterfront Revitalization Program; and be it further RESOLVED, that the Southold Town Planning Board grants Approval with One (1) Condition to the survey for SCTM#1000-45-7-3, dated January 28, 2014, last revised January 20, 2015, prepared by Nathan Taft Corwin III. The Chairman is hereby authorized to endorse the Site Plan. Condition: 1. To be fulfilled prior to the issuance of a Certificate of Occupancy: submit an As- built Landscape Plan to be reviewed to the satisfaction of the Planning Board. At a minimum, the Landscape Plan must include a vegetated, landscaped buffer along Moores Lane to break up the mass of the building. Native, drought tolerant plants are required and note that any large trees planted within the buffer must be "wire-friendly" due to utility poles and wires located in the Town of Southold right-of-way. 170 Moore's Lane [4] February 10, 2015 Please also note the following requirements in the Southold Town Code relating to Site Plans: 1. Any outdoor lighting shall be shielded so the light source is not visible from adjacent properties and,roadways. Lighting fixtures shall focus and direct the light in such a manner as to contain the light and glare within property boundaries. 2. All storm water run-off from grading, driveways and gravel areas must be contained on site. - 3. Proposed storm water run-off containment systems must be inspected by the Town Engineer at the time of installation. Please call the Southold Town Engineer prior to beginning this work. 4. Approved Site Plans are valid for eighteen months from the date of approval, within which time all proposed work must be completed, unless the Planning Board grants an extension. 5. Any changes from the Approved Site Plan shall require prior Planning Board approval. 6. Prior to the issuance of a Certificate of Occupancy, the Planning Board must inspect the site to ensure it is in conformity with the Approved Site Plan, and issue a final site inspection approval letter. Should the site be found not in conformance --- with-the ApprovedSite-Plan,-no-Certificate-of-Occupancy-may be-issued_unless the -_ Planning Board approves the changes to the plan. If you have any questions regarding the above, please contact this office. Very truly yours, ZNT,44;41". acji_AI") Donald J. Wilcenski Chairman Encl. By signing this letter, the applicant acknowledges that there are Town Code requirements and conditions, including those listed above, that must be satisfied prior to the issuance of a Certificate of Occupa cy. Print nam : AeIrs, , Applicant/Agen Signature: l Air ' Date: -2- /6 7'6 c1 MAILING ADDRESS: PLANNING BOARD MEMBERS •��__�````��F SOii ,_ P.O. Box 1179 DONALD J WILCENSKI ���/� �l0 ` Southold,.NY 11971 Chair � .4g pig OFFICE LOCATION: • WILLIAM J.CREMERSN �r Town Hall Annex PIERCE RAFFERTY �O�I1�, 54375 State Route 25 JAMES H.RICH III ���, ��� (cor. Main Rd. &Youngs Ave.) MARTIN H.SIDOR _ -COUNTI* �,�� Southold, NY '.‘a,,, St Telephone: 631 765-1938 www.southol dtownny.gov PLANNING BOARD OFFICE TOWN OF SOUTHOLD October 8, 2015 '= i OCT 8 2015 11-i; Mr. Colin Ratsey Ratsey Construction _ P.O. Box 398 I Greenport, NY 11944 Re: Approved Site Plan for 170 Moores Lane Realty Corp. 170 Moores Lane, ±130' n/w/o Moores Lane & NYS Route 25, Greenport SCTM#1000-45-7-3 Dear Mr. Ratsey: At their Work Session held on October 5, 2015, the Planning Board found that the requirements of the above-referenced Site Plan have been completed based on the site inspection made September 11, 2015. The site is now in conformance with the Approved Site Plan on the survey for SCTM#1000-45-7-3, dated January 28, 2014, last revised January 20, 2015, prepared by Nathan Taft Corwin, Ill. The Planning Board allowed the following as-built changes to the Approved Site Plan as shown on the survey for SCTM#1000-45-7-3, dated January 28, 2014, last revised January 20, 2015, prepared by Nathan Taft Corwin, Ill with hand drawn revisions by Colin Ratsey, owner, received by the Planning Board Office on June 25, 2015: • The addition of a hedgerow planted in the front yard of the subject parcel along Moores Lane; • The addition of one (1) Pine Tree and one (1) Maple Tree in the front yard; • The addition of a small gravel parking area (±740 sq. ft.) next to the office addition as shown on the as-built plan referenced above. This letter does not condone any other changes to the Approved Site Plan or approvals from other agencies; Planning Board approval is required prior to any changes to the site. 170 Moores Lane Realty Corp. Page Two October 8, 2015 Please, if you have any questions regarding this Site Plan or its process, do not hesitate to call this office. Very truly yours, 411.4(,),acj_ Donald J. Wilcenski Chairman cc: Michael Verity, Chief Building Inspector Jamie Richter, Town Engineer ,ate Scott A. Russell ,,,-- SUPERVISOR I��J[A\1�A�Gf)EI��I[]E1��C' SOUTHOLD TOWN HALL-P.O.Box 1179Tii p ilk ♦♦� 53095 Main Road-SOUTHOLD,NEW YORK 11971 \ -a - ♦♦♦ Town of So u th o l d CHAPTER 236 - STORMWATER MANAGEMENT WORK SHEET ( TO BE COMPLETED BY THE APPLICANT ) DOES THIS PROJECT INVOLVE ANY OF THE FOLLOWING: (CHECK ALL THAT APPLY) } Yes No 0E El A_ Clearing, grubbing, grading or stripping of land which affects more than 5,000 square feet of ground surface. 0 El B. Excavation or filling involving more than 200 cubic yards of material within any parcel or any contiguous area. • C1 . - • - •. , ••• • • • .- I :c.>I e ceed- 10 feet vertical rise to 100 feet of horizontal distance. E][`] D. Site preparation within 100 feet of wetlands, beach, bluff or coastal , erosion hazard area. . 0[f E. Site preparation within the one-hundred-year floodplain as depicted on FIRM Map of any watercourse. - • 0 E- F: I-nstallation--of new or resurfaced- impervious surfaces of 1,0.00. square. feet or more, unless prior approval of a Stormwater Management Control Plan was received by the Town and the proposal includes in-kind replacement of .impervious surfaces. _.; ._._.__..__ If you answered NO to all of the questions above, STOP! Complete the Applicant section below with your Name, Signature, Contact Information, Date & County Tax Map Number! Chapter 236 does not apply to your project. If you answered YES to one or more of the above, please submit Two copies of a Stormwater Management Control Plan and a completed Check List Form to the Building Department with your Building Permit Application. APPLICANT: (Property Owner.Design Professional,Agent,Contractor,Otter) S-C•T.M. s: 1000 Datc District NAME c C- 1). /L.R. 7 `/ 7 ..,, /-/,,2,-/ S 6( tr,.�t Section Block Lot Civ ""' / '4"4" FOR BUILDING DEPARTMENT USE ONLY +'" Contact In(orrtutiorz 17177'0T 7 9,1,2_474/r (9�5(7 ��� Reviewed By: jd atiqpIL y: {pIL Date: --a_ I, — J'5 Property Address / Location of Construction Work: __r_4 b Mna r-C/5 (v L Approved for processing Building Permit U 17Stormwater Management Control Plan Not Required. 1J1�(eQ,j(1 Q� ! v^r•I�/- 1/191/el (� Stormwater Management Control Plan is Required. l , (Forward to Engineering Department for Review.) FORM ' SMCP - TOS MAY 2014 --�---- --- ----___ -- - - - - 61o19,) . JAN 21 2015 Southold Town Planning Board SURVEY OF PROPERTY SITUATE GR NEN PORT TOWN OF SOUTHOLD SUFFOLK COUNTY, NEW YORK S.C. TAX No. 1000-45.-07-03 SCALE 1 "=30' JANUARY 28, 2014 OCTOBER 14, 2014 REVISE PROP. BUILDING LOCATION NOVEMBER 4, 2014 ADD PROP. DRYWELL JANUARY 20, 2015 REVISE DRYWELLS AND ADD ADDITIONAL NOTES AREA = 51 ,534 sq. ft. 1 .183 ac. • THE UNDERSIGNED,PURSUANT TO SOUTHOLD TOWN CODE SECTION 280-131(1),ACKNOWLEDGES THAT THE CONDITIONS OF THE SITE PLAN PROVAL SET FORTH IN ij.. r,OLUTION OF AP' ' • .,. DATED 4,/201.4_,ARE A i SEI;S.ONDMO. •;,• • • !ON). P • JO v /� i AUTHODSIG.r • TITLE DATE�-- APPROVED BY TOWN OF SSOUTHOLD PLANNL'VG BOARD • CHAIRPERSON SIGNATURE . NOTE:"Ile approved site develo t plan shall be valid fora period of eighteen(I8) mond from the date of approval as per code section 280.132A. 302.39' FENCE 1.2'S. 2.6•W. = O (.D • Z= w 0 w Z_ o , I O Ci) _.._....--__.�_.�_r.. , .+,+wf+�E�1-sa�rs�a�islm.�7.7�rsRaP1�',. x - •-, iIRd�MeR.M t ( • • J I) \ 1 1 � ' - _C _ -__ _Ii. ---a- (/ 9 -- 1.0 ..-0,45-.47° iitier-- '4.?.. 0-..., : /14 TOWN OF SOUTHOLD PROPERTY RECORD CARD --i9 OWNER STREET / 70 VILLAGE DIST. SUB. LOT I.. D Moore's l_._a-ne OD ea t C`� c -744 6- !.� flaht.e - il..,2P�t/A.--4-0/ /6 l s�- „FORMER 0 INNER 1 N / E� � R. ./p74. /i'As sg- ""hoa S / - ' I/CL_ AGay � v I : r S W TYPE OF BUILDING Sean;ck Mahn ASS`• . -1)4-/ia n e tic /7�r�o• ce DDI- C' J L RES. SEAS. VL.- FARM CO/vM4-40CB. MICS. Mkt. Value . ` 7 LAND IMP. TOTAL DATE REMARKS /11/4 3/7 9 1-4 3 6 o ;) . r,--)r-6 3a „3 OO - .- - Li 3 o o a o , c-v--- q` 3 a o,/"/ a,� 4300 3 d o ✓ ih-i9 /7 2.---1'' / y/gAi,/ Cntiii >Lr ,!)0/tf o . • 3 (5 0 /5%-r? 0 - S O U ✓ IA 3/2:1,- f rC ui ,`T •� 0 a 0 /. -4//?L A--. 7.3 9300 2 .)'0 0 // e o d ,1,,i,,, / 7.' 1/9/7gr BLD, PrrR. it ?tic; Z BLD PbO, ,oa7 LIC 4 30, 000 1.7 /.?o.-e) /z o aU /' / a 0 / '57,1/7c . 11.2 _1642.-L_ t(--,, 3 �05-1eirnick 4v Igo Moore's)4.,0 Z300/ 3 t t ) I I II P110)o ( P# 33S replaces Pt'.. %IO \J r...C. 2-IZooI 3\i ► 1 -C 07.4- oYd-;r 1 L 1 ► — OChbi--1011 I —., ►zoc) • I 0lt0 )3—$p4 /O (- rro.fl/ ceS# 3ss'</3 Tillable FRONTAGE ON WATER Woodland FRONTAGE ON ROAD / 71, 3 /� 07 S, D-6 ; il 2 '7?)' Meadowland DEPTH 3 6 7 . 4 4/ House Plot BULKHEAD Total , -......,„ OR TRIM . i uIflhIuu, 1 . i ____----, ,- . .4,-,..14.0•••;,=•+;-.4.,."..$IP, I, .-:xl..,,,,- ';,...:, ,,,-..,, .4 1 11111 ::'- -.4-7,,-----i.x., ‘ -_,i_.- '-',- ; ';—::::.:7::;1,:-: :^N,./.,...;Stil ZiT'`-'',,..-i''.-•!7!7j7..."`„,"'-.:::,::::;;:-,„ ' ..,..:..,..,,,,„t..-..,.,;;,..., ,.......- pAriP..'., ,.:,•4,4,A,# . ,- ..,,V0-'''A .1, ..r• ',-;-:4: '--: ;i''.-4 4 IT 7t,t$ _ ,4!, .;-,,:,,,,- ,,,.• ;•'',.-',, ,.„.: -,,, '144-4 ..-.,# '"P:31,,r`AP, , .%.r :. '6U - itT'k 14',F 3' ; k,,e,=•• ":-.0-,=`',.- ERmr-K-4-1--.'4-,ttv-0.,==':=,-,==4•-",'t• -,.. Ar ,;,''', ----I '--, rp'.4; ,‘,,--4,t.,..i.- ' . , I III _ [, IIII . - :''''..%.... 6. .41.,_.(-„, ',.• .,,,,,,, -••"" _ , III I I I I ' ''.4'. 4I-' L.' :.'- '-.t .7,13 .•-'.7sy..- -,>,..._ 7 ' ','7'."- ".3"'"r,--,''', , -''- -' 't" —..,,-'' I ' 7'4''-'.k•43.4' '''' 7-4.3,,,,,,': ,. '„,—,-,,--"-'n".,,,' :,- K4'47165':';.•' ' -,— i ,E-'3= , , :: ' : - . ,. ""' , Millili IIIII , ,.,..1,7----, , , ,,,,,-74,-,-,,-,•L=,-*,,,v ',..= - -.•-.Z:`-;,.',64,-s..' "•!:= '•:,', ;`-'''''r-,t4,-C,,S7, ' ,, ;,..' , `- , ,.-- , . I MIME • MEP I / , M. Bldg. e- yco x / 1 s -._ / o o p 15 .'7 s 7 s-°° -i 11.111.111' 111.1111.1u•imarom11111111611111111.4.1.111111 II 11.11111 1111.111 II 111111111111 —1--- RU Extension ....- •/,? 66 . 7,r 1/14.A 11.111111111E1111111.111.1.• 1 I 1 . Extension Ma MEM 111.1111111111111111111111111111111111 MEI 11111111 Extension _ • Foundation ‘- , Both A/ 0 Dinette - Porch I) Basement /V Floors Co fe.... • . K. Walls At.u vv\ Porch Ext. Interior Finish LR. DR. Heat Ato lio — . . Breezeway Fire Place i BR. - . . Type Roof Garage — Rooms 1st Floor Patio n • mecreation Room Rooms 2nd Floor - FIN. B • Driveway Dormer 0. B. - . i 1 _ Total /71.0 ed 0 ./ .._ COMcheck Software Version 4.0.0 (114/ Envelope Compliance Certificate L I i Project Information rc) /ID) .) Energy Code. 2012 IECC id1rJ2015II;J Climate Zone: 4a Project Type. New Construction , Vertical Glazing/Wall Area: 13% —� , - •,1)i -OLD Construction Site: Owner/Agent: Designer/Contractor Moore's Lane Jernick Moving &Storage Nancy Dwyer Design Consulting, Greenport, NY Moore's Lane Inc. Greenport, NY Southold, NY Building Area Floor Area 1-Office . Nonresidential 1085 Additional Efficiency Package High efficiency HVAC Systems that do not meet the performance requirement will be identified in the mechanical requirements checklist report. Envelope Assemblies Assembly ; Gross Area Cavity Cont. Proposed Budget U- or R-Value R-Value U-Factor Factor. Perimeter Floor 1 Wood-Framed,[Bldg.Use 1 -Office] 1120 0.0 ' 19 0 0 044 0 033 Exterior Wall 1 Wood-Framed, 16"o.c.,[Bldg.Use 1 -Office] 882 ' 0.0 15.0 0 053 0 064 Window 1 Wood Frame•Operable,Pert Type:Energy code default, 114 — — 0.550 0 450 Double Pane with Low-E,Clear,SHGC 0 70,[Bldg.Use 1 -Office] Door 1 Wood,Swinging,[Bldg.Use 1 -Office] 42 — — 0.500 0.610 Roof 1 Insulation Entirely Above Deck,[Bldg.Use 1 -Office] 1120 — 30.0 0 032 0.039 (a) Budget U-factors are used for software baseline calculations ONLY,and are not code requirements. Project Notes Single story office addition to exterior of existing warehouse Envelope PASSES: Design 1% better than code Envelope Compliance Statement Compliance Statement: The proposed envelope design represented in this document is consistent with the building plans, specifications,and other calculations submitted with this permit application The proposed envelope systems have been designed to meet the 2012 IECC requirements in COMcheck Version 4.0.0 to comply with the mandatory requirements listed in the Inspection Checklist. Matthew Sherman 04 . 07 . 15 • Name-Title Signature Date • Project Title: Jernick Moving&Storage • Report date: 04/07/15 Data filename: C:\Users\matthew\Documents\COMcheck\Jernick.cck Page '` 1 of 16 COMcheck Software Version 4.0.0 Interior Lighting Compliance Certificate rdt Project Information . Energy Code 2012 IECC Project Title: Jernick Moving&Storage Project Type: New Construction Construction Site: Owner/Agent: Designer/Contractor Moore's Lane - Jernick Moving&Storage Nancy Dwyer Design Consulting, ' Greenport, NY Moore's Lane Inc Greenport, NY Southold, NY Additional Efficiency Package High efficiency HVAC Systems that do not meet the performance requirement will be identified in the mechanical requirements checklist report. , Allowed Interior Lighting Power , , A B C • D Area Category Floor Area Allowed Allowed Watts • (ft2) Watts/ft2 (B X C) 1-office areas(Common Space Types:Office-Open plan) 1085 1 1085 Total Allowed Watts= 1085 Proposed Interior Lighting Power . A B C D E Fixture ID: Description/Lamp/Wattage Per Lamp/Ballast Lamps/ #of .Fixture (C X D) - Fixture Fixtures Watt. 1-office areas(Common Space Types:Office-Open plan) Linear Fluorescent 1 24"T8 17W Electronic: 4 15 68 1020 Total Proposed Watts= 1020 Interior Lighting PASSES: Design 6% better than code Interior Lighting Compliance Statement Compliance Statement: The proposed interior lighting design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application.The proposed interior lighting systems have been designed to meet the 2012 IECC requirements in COMcheck Version 4 • 0 -•• o omply with the mandatory requirements listed in the Inspection Checklist. -Matthew Sherman -....ill.. 04 . 07 . 15 Name-Title Signature Date • Project Title: Jernick Moving,&Storage Report date: 04/07/15 Data filename: C:\Users\matthew\Documents\COMcheck\Jernick.cck Page 2 of 16 COMcheck Software Version 4.0.0 14 Exterior Lighting Compliance Certificate Project Information Energy Code. 2012 IECC Project Title: Jernick Moving&Storage Project Type. New Construction Exterior Lighting Zone 2(Light industrial area with limited nighttime use) Construction Site Owner/Agent: Designer/Contractor Moore's Lane Jernick Moving&Storage Nancy Dwyer Design Consulting, Greenport, NY Moore's Lane Inc. Greenport, NY Southold, NY Allowed Exterior Lighting Power A B C D E Area/Surface Category Quantity Allowed Tradable Allowed Watts Watts/Unit Wattage (B X C) Main entry(Main entry) 1 ft of door 20 Yes 20 Private entry(Other door(not main entry)) 1 ft of door 20 Yes 20 Total Tradable Watts(a)= 40 Total Allowed Watts= 40 Total Allowed Supplemental Watts(b)= 600 (a)Wattage tradeoffs are only allowed between tradable areas/surfaces. (b)A supplemental allowance equal to 600 watts may be applied toward compliance of both non-tradable and tradable areas/surfaces. Proposed Exterior Lighting Power A B C. D E Fixture ID : Description/Lamp/Wattage Per Lamp/Ballast Lamps/ #of Fixture (C X D) Fixture Fixtures Watt. Main entry(Main entry 1 ft of door width).Tradable Wattage LED 2: LED Other Fixture Unit 28W/ 1 1 28 28 Halogen 1 Halogen 120W 2 1 '200 200 Private entry(Other door(not main entry) 1 ft of door width):Tradable Wattage LED 1 LED Other Fixture Unit 6.5W 1 1 11 11 Halogen 2:Halogen 55W 1 1 100 100 Total Tradable Proposed Watts= 339 Exterior Lighting PASSES: Design 47% better than code Exterior Lighting Compliance Statement Compliance Statement: The proposed exterior lighting design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application.The proposed exterior lighting systems have been designed to meet the 2012 IECC requirements in COMcheck Version 4.0.0 o comply with the mandatory requirements listed in the Inspection Checklist. Matthew Sherman 04 .07 . 15 Name-Title Signature Date Project Title: Jernick Moving&Storage Report date. 04/07/15 Data filename: C:\Users\matthew\Documents\COMcheckVernick.cck Page 3 of 16 COMcheck Software Version 4.0.0 444 ril Mechanical Compliance Certificate Project Information Energy Code. 2012 IECC Project Title: Jernick Moving&Storage ' Location: Suffolk County, New York Climate Zone. 4a Project Type. New Construction Construction Site: Owner/Agent: Designer/Contractor Moore's Lane Jernick Moving &Storage Nancy Dwyer Design Consulting, Greenport, NY Moore's Lane Inc. Greenport, NY Southold, NY Additional Efficiency'Package High efficiency HVAC Systems that do not meet the performance requirement will be identified in the mechanical requirements checklist report. Mechanical Systems List Quantity System Type&Description ' 1 HVAC System 1 (Single Zone): Heating: 1 each-Duct Furnace,Propane,Capacity=38 kBtu/h Proposed Efficiency=95.00%Ec,Required Efficiency=90.00%Ec Cooling: 1 each-Packaged Terminal Unit,Capacity=19 kBtu/h,Air-Cooled Condenser,Air Economizer Proposed Efficiency=15 00 EER,Required Efficiency=9.50 EER Fan System: None Mechanical Compliance Statement Compliance Statement: The proposed mechanical design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application.The proposed mechanical systems have been designed to meet the 2012 IECC requirements in COMcheck Vers 4 0 0 - . to comply with the mandatory requirements listed in the Inspection Checklist. Matthew Sherman -G 04 . 07 . 15 Name-Title Signature Date c NEwyN�Atij/N00,9�1 yCp *835th vki.• 19ESSIONP Project Title. Jernick Moving &Storage Report date: 04/07/15 Data filename: C:\Users\matthew\Documents\COMcheck\Jernick.cck ' Page 4 of 16 COMcheck SoftwareChecklist Version 4.0.0 Inspection Energy Code: 2012 IECC Requirements: 23.0% were addressed directly in the COMcheck software Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. 2 012IECC, ,. Plan.Review iw Complies?:, , ',Coiriments/Assumptions' „. ,s4 C103.2 ;Plans and/or specifications provide all ❑Complies [PR1]1 'information with which compliance ❑Does Not can be determined for the building envelope and document where ONot Observable exceptions to the standard are ONot Applicable claimed. C103.2 ;Plans, specifications, and/or ['Complies [PR2]1 !calculations provide all information ❑Does Not ;with which compliance can be ;determined for the mechanical :Not Observable systems and equipment and :Not Applicable ;document where exceptions to the ;standard are claimed. Load calculations per acceptable ;engineering standards and ;handbooks: C103.2 ;Plans, specifications, and/or ❑Complies [PR4]1 'calculations provide all information ❑Does Not with whichcompliance can be •determined for the interior lighting ['Not Observable and electrical systems and equipment ONot Applicable and document where exceptions to the standard are claimed. Information , provided should include interior lighting power calculations, wattage of bulbs and ballasts,transformers and control devices. I I C103.2 Plans, specifications, and/or ❑Complies [PR8]1 calculations provide all information ❑Does Not iwith which compliance can be ONot Observable ;determined for the exterior lighting land electrical systems and equipment ONot Applicable ;and document where exceptions to ;the standard are claimed. Information provided should include exterior lighting power calculations,wattage of bulbs and ballasts,transformers and control devices. i I -I C406 I Plans, specifications, and/or ❑Complies (PR9]1 calculations provide all information ODoes Not with which compliance can be determined for the additional energy ONot Observable efficiency package options. ❑Not Applicable C402.3 1 ;Vertical fenestration area <= 30 ❑Complies [PR10]1 !percent of the gross above-grade wall ❑Does Not ;area. :Not Observable 1 ONot Applicable 1 High Impact(Tier 1) :2 Medium Impact(Tier 2) •'3.,, Low Impact(Tier 3) Project Title: Jernick Moving &Storage Report date• 04/07/15 Data filename: C:\Users\matthew\Documents\COMcheck\jernick.cck Page 5 of 16 • , ` {�^ ^� �r _ ^ ^ '� � ' ?p^*°��� '`� � �'�-� `�� \ ���/ ' .';6, + �, °���, ����' `'�� .;* `/ '+��_^���^ ^�� *��'� �. ^ ''»`� ���.r��•°v' c402�.1 Skylight area <= 3 percenof the EIComplies [pnzz]^ gross roof area LJoves Not |LJmctobsemab|e |LJmct Applicable c402.3.2 l In enclosed spaces > zn'ouoftz []Complies [Pn14]1. directly under a roof with ceiling ODoes Not heights >15 ftand office, []mntousemab|e |obby, atrium, concourse, corridor, ' St []motApp|icab|e convention center, automotive |service' manufacturing, non- !refrigerated warehouse, nn'|,ef,iue,atedwa,ehouse' retail store, distribution/sorting area, transportation, workshop,the following requirements apply. (a)the daylight zone under skylights is >= half the floor area; (b)the skylight area to da |i ht zoneis >~ spo,cent with a skylight VT>= 0 40; or a ' minimum skylight effective aperture !>= 1 percent. c402.3.2. Areas with obstructions that block LJcompxes 2 direct beam sunlight on >= 1/2 of the []ooesmu, [pnl5], roof over the enclosed area for more ONot Observable :than zsoodaydmehours per year !between oannand 4pm. []wo«xppxcab|e Additional Comments/Assumptions: ^ • • • . 1 High Impact(Tierl) Medium Impact��2> � Low Impact(Tiers> Project TitleJernick Moving&Storage , Report date: 04/07/15 Data filename. cAuaa,s\matthew\oocuments\coMcxecmdemick.cck Page 6 of 16 • 2012 /,Foundation Inspection tc?"mti!)0 ? C403.2.7, Exterior insulation protected against OComplies Requirement will,be met. C408.2.8, damage,sunlight, moisture,wind, ElDoes Not C404.5 ,landscaping and equipment (F06]' maintenance activities. ['Not Observable EINot Applicable C.:403..2,4;,„Freeze protection and snow/ice 'ElComplies *N4-24, •`, :d melting system sensors for future ElDoes Not ti:D9ift4iconnection to controls., ['Not Observable 1:1Not Applicable C402 2'43i'; Bottom surface of floor structures EIComplies Exception: Requirement does not apply. TE012;WM: incorporating radiant heating ODoes Not 1 insulated to >=R-3.5 See the Envelope Assemblies table for values. :Not Observable ;;Y3N':!f,c,,,P2V44 EINot Applicable Additional Comments/Assumptions: • • • 1 High Impact(Tier 1) Medium Impact(Tier 2) Low Impact(Tier 3) Project Title: Jernick MOving&Storage Report date: 04/07/15 Data filename. CAUsers\matthew\Documents\COMcheckVernick.cck Page 7 of 16 ;.,,4 * i/." 4� 1 r "Plans.Verified.'' :.:Field,,.Venfied • ` in rItOn h-!Han4iection �,:•'' •, .,; Com'i lies?i rGomments�Assumptions°",V #., Frain g:/. 9 P -Value f.' `:Vali e4. ^1.: P ',, :;,;, C402.4,1,. 'The building envelope contains a f...e' A,t'^: `- ( ' ' ❑Complies Requirement will be met. C402.4.2 !continuous air barrier that is w> ";°; y{`,- r` '�,'" ❑Does Not [FR16]. ;sealed in an approved manner ,,,- ' _' r „,:7.0,,,=4„ and either constructed or tested °s:'' ' ' x -'#'❑Not Observable -: . ,,"� ,;''`r.'-`. Q .Wil.',.; ❑Not Applicable lin an approved manner Air ' :. ;:'.3-:.': ' :,,:;,' .1' : lbarrier penetrations are sealed in 'r�,,. �• - . :: •ijt � r C !an approved manner, • '. .:,. ;:h ' : •'-i a .,:::';'.,:‘k,'":'-',E-.71,..,;1 C40214 3;-`�IFactory-built.fenestration and +'_ :y` 04. , ,`.° ;=s"' ❑Complies ' Requirement will be met. 'C'46-243.-40'doors are labeled as meeting air ''•'r '' `' ;;;i "1'^4i ,4,-a,,,,,..,:.... -:F' r.'. DDoes Not [FR18] °:'leakage requirements. .'', '; - i•;-i-r ,,,..,1,:47;-- --- , ..,*, s- h:'a..A':..^<:,v;• = :❑Not Observable F:t;;'',V;''A,%1'! ,; ,,:`',,.'.'-'"r,;t%!`1's'-"ii:- ?';t:0"-'' .'' • - T'^❑Not Applicable _ =,?' . ,.'rti.._ ;Y : ;` •<i:'r. ;° :;,❑Com lies C402°47'i'Vestibules are installed on all ":a •�` _`:;=': p ' [FR3 i ,. ;,. r,'1 ,"•, ❑Does Not �17] `j1 building entrances. Doors have $;.",�.,�;�+,^2 •`�•-•;,p, -_�- .�^,,_: >ryr`*>-;=.4re.,iself-closing devices. =„ `'• ;°,is:' h.1 .,';:','.4', :,. ^`j ' ❑Not Observable 'F':sf:-<';<t Tr � rt.u:... ,• :'...':'''-;'%,','• ;44,1-. we--',...:,, ❑Not Applicable C402.33, ;Vertical fenestration U-Factor U- U- EComplies See the Envelope Assemblies C402.3.4 ' ODoes Not table for values. [FR8]1 ❑Not Observable ❑Not Applicable C402.3.3 {Vertical fenestration SHGC value. SHGC. SHGC: ❑Complies See the Envelope Assemblies [FR10]1 i ," ❑Does Not table for values. ❑Not Observable ❑Not Applicable •:4-"�` - ' T' "'Y F:' "`'``', .,;.6' ' •`❑Complies Exception: Default values •'C303r1p°31 Fenestration products rated in _'.r:ir> v.`re„_4*':l�,,,, ~.'G .,, z; - ' :: ,: ,.s,'":,s h:; :=' r .=';*;.'-, _ are used, '.14:',,K.2],'t'{rY accordance with NFRC. .0± ;,...e,,,',:0-,.E, , Does Not ” 41 ,-It t ` ,.*d, j zt� .f. .;.-4..:1!;:',::::;;;';,,k ❑Not Observable ,,vi ,jSL;?r` 4i ;a;,.• ^r '▪^ .t' „ - A, . lkii'". ..:.--•,:::; Py ❑Not Applicable C303 1,3 ;Fenestration products are ' :"i:`& ,?_ ',�':‘':r." i,, ;' ❑Complies Requirement will be met, [FR13]1 certified as to performance labels ;;: •,.0s.-r,„.::!',,.e `�7°;:'•1 ;';''',::; rte',"'s ❑Does Not j or certificates provided t." ,,,.,Gti, a;: 4 ` .' h_,,,�: ?'>,?':;•'. 1,k.:,..,,,,"` !:,•' - ;.�.„ ,.. . t==” ��: ❑Not Observable µ.,,,. ::....„.h.,,,,..;,.r �;,^▪ w;`°, ;64;. ': 1.".-:';`,.:,.❑Not Applicable :C402l'k ..•tF �2'7''; U-factor of opaque doors U- U ❑Complies See the Envelope Assemblies [.FR141??n4 ❑Does Not table for values.associated with the building ❑ Swinging ❑ Swinging Al*: ,:,. ,A thermal envelope lope meets r ❑ Nonswinging ❑ Nonswinging ❑Not Observable ; . ' ,;requirements ; '4"Vf`; ❑Not Applicable 4,0'Additional Comments/Assumptions . , • 1 High Impact(Tier 1) '2 Medium Impact(Tier 2) .13.=. Low Impact(Tier 3) Project Title Jernick Moving&Storage Report date. 04/07/15 Data filename: C:\Users\matthew\Documents\COMcheck\Jernick.cck Page 8 of 16 .- .. ,Is ' Efficiency: Efficiency. []comp�ies See meMecoan�v Systems list ' equipment efficiencyvalues. v��d u�� m� for ['Not Observable ' ' ONot Applicable Stair and elevator shaft vents []Complies Exception: Requiremept havemo�ohzeddampeothat • LJDoesNot doesnotapp|y. au�omadca||ydose � ▪ []NotObsemab|e ^..^~^ � .~ �../—�, i- &_� �_ ���-Y��/- !. :Not Applicable pp|icab|e Outdoor airand exhaust • L��mp|ies Exception: Requirement havemotohzeddamperstha� does not apply ' ▪ automaticallyshutwhennc�inuse and meet maximum leakage ' ['Not ' ][ NotApplicable • rates.[heckgravitydampers where allowed. ��'����������'���������������^��� �� '[[4O3�Z�5 |Demandcpntvo| vend|abon ][omp|ies 1 provided for spaces >500 ft2 and J7:7 • LDnesNut [ME59]1 >Z5peop|e/lOUOM2occupant • []NotObsemab|e density and served b systems with air id economizer, auto • [ NotApp|icab|e modulating outside air damper control, urdesign airflow >]'O0O cfm. , if ����������������������*�^��p��' �V�[duc�sandp|enums ' R�___� R�____ [][omp|ies . insulated.Where ducts or ODoes Not . pleriums are installed in or under ['Not Observable ' as|ab ve,i�cadonmayneedto ' occur during Foundation []NotApp|icab|e �X��Q41,4|nspecdon. Thermally ineffective panel Complies su�acesofsensib|eheadng • DpesNot � . � panels have insu|advn >= R'3.5 " Not Observable . �r�« � /��� NutApp|icab|e Ducts and plenums sealed based Complies ^ oqstadcpessu,eand |ocation. Does Not � � • Not Observable ` �` »'� ' �` ; NntApp|icab|p��� � ����� ,,ouctwurkope,adng >3in water ' L [ump|ies ' ^ cu|umn ,equiesair|eakage • []Does mut testing. []NutObsemab|e t+�� '� �;��c��^'�'*/ � []NutApp|icab\e 7 _-_4 , ' - - - �� . ��rovd�sandzon�tennina| - LJ[omp|ies devicesxavemeansforai, �� []DnesNot [ balancing. � ` []NntObsen/ab|e `' ^��«� i. .' ' %����������3[]NutApp|icabke VAVfan motors >=7.5hptobe 0 VSD 0 VSD []Complies ' u,ivenbyva,iamespeedd,ive' I=1 Vane axial Ei vaneaxia| []ouesmot ' ^ have a vane axial fan with fan fan ' []mo�dbsemab|e variable pitch bladesorhave 0 Other �� Other 'controls to limit fan motor ENot Applicable demand. AT,Ickm"a-,, ' [4V326 Exhaust air energy recovery on []Comp|ies [ME57]1 sy�emsmeeting Table C4O326 - • []DoesNot []NntObsenab|e � | � �^� '����°��:����l�, .��[]NotApp|icab|e � 1 High Impact(Tier 1) .,,!2', Medium Impact(Tier 2) �� Low Impact(Tier 3) Project Title: Jernick Moving&Storage Report date: 04/07/15 Data filename: C:\Users\matthew\Documents\COMcheck\Jernick.cck Page 9 of 16 ,kt �� y. 1 C. !� i ..:: - (;�;:.• c• c�r a Section•' ."t.' wA': Mechanical Rou �h-In• p�.,;- �.P..Ians��Verified: '"Field�.Ver�f'ied` _ - - 9 � ° - u;Gom`�lies?r - 'Gonments/Assumptions :Ins p ectionr "4 i Value Value_ P, �, p.. x C403 2 1]! Unenclosed spaces that are w` if' `:� =3=': x ❑Complies `[ME.71j3Y: A heated use only radiant heat. :•-_ rt3, , �,,,, „. >'; :}; br ';; ` • y Does Not r i•Y5 ra, •=+rx,.^;_ , � �r R DNot Observable • .,.N r, tv! `` ``r r; ,+`.+ ❑Not Applicable C403.4.7 IHot gas bypass limited to, <=240 li ` ;' '',?r`' 4;_--"-' ❑Complies [ME35]1 IkBtu/h-50% >240 kBtu/h-25% rs`c:rii; 'is.j }' ❑Does Not •„ [Not Observable :: ❑Not Applicable • Additional Comments/Assumptions: • • 1 High Impact(Tier 1) :3•., Medium Impact(Tier 2) 3' Low Impact(Tier 3) • Project Title: Jernick Moving&Storage Report date: 04/07/15 Data filename: C:\Users\matthew\Documents\COMcheck\Jernick.cck Page 10 of 16 ' ' . . � . � . . ' � Automatic controls to shut off all building lighting installed in all LJDoesmot . buildings. ONotobsemable []m,txpp|icab|e • Independent lihti gcontm|sinstaUed OComplies RAMAIS per approved lighting plans and all ['Does Not manual controls readily accessible and []No«Obsemab|e � visible tnoccupants � 0.4mt.'40,KW ' []NutApp|icab|e ' c405.2 1 Lighting controls installed to uniformly Ocomp|ies 2 I reduce the lighting load by at least LJooesmvt ' [EL15]1 snm , � LJmotObservab|e | []mct*pp|icab|e plp%:2,:i3,4 Daylight zones rovided with LJCump|ies individual cnntm|sthat control the LJDoesNot ' ' lights independent of general area []NotObsemab|e ' |ighting� • LJNotApp|icab|e • Sleeping units have at least one []complies master switch at the main entry door LJooes Not that controls wired luminaires and []NotObservab|= Iv,C.;1''E,V,,'',Ati switched receptacles []Nc�xpp|icab|e 61-,, _ c4052.2. ;Occupancy rs installed in []Complies . , ' 2 ��|n�spaces. u��m� [sLzq]^ Not Observable • ) ONot Applicable • ' c405.2.2. !Primary sidelighted areas are []complus . 3 equipped with required lighting []moesmot [ELao]` controls. Not Observable - . | []motxpp|icab|e /. c405.2.2. ;Enclosed spaces with daylight area ElcvmFx/es . . 3 under skylights and rooftop monitor0ovesmut [Ec21]1 are equipped with required lighting ^~motousemab|e controls. . []motAppxcame ' Automatic lighting controls for exterior EComplies . . lighting installed �� Does Not '- '' '''''''0,-T$1 44411!a:N UNotObsemble Wtt9t4 Ki,'. []NotApp|icab|e ' c405�.3 lighting control devices for OComplies ' [sL4]z specific uses installed per approved LJooesNut . lighting plans . ONot0hsemable - . | . _ ' []Nnt»pp|icab|e Fluorescent luminaires with oddOComplies numbered lamp configurations that. ODoes Not ' ' are with 10 feet center to center(if ['Not ,ecessmounted) o,amwithinlfnot . edge tuedge(if pendant ursu�ace []m��xpp|icab|e �o�� �� � mpunted) sha|| betandemwi,od. , ' • c405.4 Exit signs do not exceed 5 watts per []Complies [sLs]z face ODoes Not :Not Observable . . ' :Not Applicable ' . . ` , • 1 High |����z) � Medium Impact(Tier 2) �� Low|mpaet(Tier 3) ^ ' . Project Title: .]ernickMoving&Storage . , Reportdate 04/07/15 Data filename: c:\users\,natthew\oocuments\coMcxeckUemick.ccu Page 11 of 16 . . . S 5S "t: 4 2012 lEtt Rqugh,likEieciril,14tieCt!Ory •;t: S. rS:!. C405.6 'Exterior grounds lighting over 100 W DComplies [EL24]' iprovidés >60 Im/W unless on motion ODoes Not sensor or fixture is exempt from scope I of code or from external LPD. ['Not Observable DNot Applicable C405.2.3 'Additional interiOr lighting power DComplies [EL8]' !allowed for special functions per the ODoes Not :approved lighting plans and is I 'automatically controlled and DNot Observable !separated from general lighting. ONot Applicable • • Additional Comments/Assumptions: • • • • • • • • • • 1 High Impact(Tier 1) 2. Medium Impact(Tier 2) Low Impact(Tier 3) Project Title: Jernick Moving&Storage Report date: 04/07/15 Data filename. C:\Users\matthew\Documents\COMcheck\Jernick.cck Page 12 of 16 . . . C402.4.1. x | souro�pfair in the ` • Requirement wiUbeme� z ;building the,md| enveopea,e LJDoesNnt''.,,,!-6,1_,•-'4',1-... .[|ml] ;sealed, caulked, keted ['Not Observable ;weather'^'',,^~ `' wrapped with~ []motApplicable mostu,evapo,penneau|e -. wrapping material to minimize air '°'v� ;leakage. � �� ��� ���` ��� � - ���� � , �� �` l -�- �� ' . c402.4.2. noofn'va|ue. For some ceiling R- R- .Lcump|ies See mesn,emneAssemm�s ' u,umm,,a/uasz systems, verification may need to LI Abovedeck LI Abovedec� , Does Not [|mz]z occur during Framing Inspection [� Metal [] Metal :Not Observable ' 0 Attic [] Attic []motApp|icab(e . I [30I2 Roof insulation installed per LkComp|ies Requirement will be met. [|N3]zman�actuver's instructions. LJDoes Not 8|ownorpuue� |ons��U � ['Not Observable insu|adonisinstaUedon|ywnee ��^ �'::',P.''''' �� []NotApp|icab|e{the roof slope is <=3 in lZ� .'�'� .� e,� � . � e=� . .�vz . [3Os.z | wall insulation LJ[omp|ies Requirement will be met. [|N7]1 installed per manufacturers []Doesrict ' instructions ONutOhsemable � . �`��'• [��,�[]NotApp|icab|e ' [F|vv,insu|a�onn*a|ue� R- R- compes the Assemblies_ __ O table for values. ' 0 Mass 0 MassDoesw� � , pStee| pStee| []motObsemabie ' pyVood 0VVood []mutApp|icab|e Floor insu|adnninstaUedper • `^ •':;•',•:-.,'[]Cump|ies 'nequinement wiUbennet. manufacturer's instructions. ' ` ��� LJDues Not ` []NotObsemab|e !!;;;.i.2.1.-40.4.>;-,40! ������ �����-��'� ������'��.�����^��"/,�LJNutApplicable ' 8ui|dingenve|vpeinsu|adon is [ Complies RequirementwiU be met. []|abe|edwithR+/ |ueo,insu|adunif Does Not certificate providing n'va|ueand '' '� LJNc�O�semab|e c�herve|evantdata =, • `°�v����� �����°�� ����' ���������[]Nct Applicable Exterior insulation is protected ' • � []Cnmp|ies Exception: Requirement hnmdamagewithaprotective ' []DoesNot does not apply material.Verificationforexposed - � � r `� :Not Observable foundadoninsulation may need � ' : []motxpp|icab|e touccurdu,ingsoundadon �^ " 't.•"-. �`' Inspection ���� ���� `•+e •` � |nsu|adonintended tomeet the �� ' [][ump|ies 'Requirement wiUbemet. ( ronfinsu|adunrequivemen�s �� []Dues Not cannot be installed on top of a ^� ° '/`�'� " ' ' ['Not Observable � suspended ceiling Mark this � ' []wo��pp|icab�e ' vequi,ementcomp|iantif ��,�� , �. insu|adonisinstaUedaccordingly ���������5�����, i���.����a _�� . ` Additional Comments/Assumptions:. . . . ., ' . ` . � � � . , . 1 High Impact(Tier 1) '-'''2., Medium Impact(Tier 2) �3� Low Impact(Tier 3) ' Project Title: Jernick Moving &Storage Report date. 04/07/15 Data filename: cAuse,s\mauhew\ovcuments\coMchecxUemicxzcu Page 13 of 16 4 2012'IECC. ' Final Inspection Complies? 4a Comments/Assumptions: C402 4 6 1 Weatherseals installed on all loading ❑Complies Exception: Requirement does not apply. [F137]1 dock cargo doors. ❑Does Not ['Not Observable • j ONot Applicable • .,C403,2`t4�`�s Heating and cooling to each zone is ❑Complies i24.� i �Y�.I.,L �''zi;Wj.:.-controlled by a thermostat control. ❑Does Not [F,147]3••.:;4;?;•Minimum one humidity control device :Not Observable '..''',':;0•,:,,..-2,,,,,- per installed W=N'4s:`,7:'': humidification/dehumidification ONot Applicable p.,04,,,,,,„,,, ,, system. . C4032,;4. Thermostatic controls have a 5 °F ❑Complies ,2?�;:�ti , deadband ❑Does Not [Fi38]3 ;y�.' [Not Observable ;''�'ii':-.2",•-•3";• ,.,` " ;• ONot Applicable C403.2;•4�`;Temperature controls have setpoint ❑Complies 2„r= ':x.>;ia,,;,:l overlap restrictions. ❑Does Not -''..x;. • ., ❑Not Observable ,(:+_� ONot Applicable C403'2:4';'. Each zone equipped with setback ❑Complies 3,e ;;-;;,-c,,, controls using automatic time clock or ❑Does Not [F139;]3%;* programmable control system 5-: "'ro;tr - :Not Observable Tor:- ;' "';:: 1 ONot Applicable ..C403 2:4 ' Automatic Controls. Setback to 55°F ❑Complies '"''''r4'11(heat)and 85°F (cool); 7-day clock, 2- ❑Does Not ;[F140]3'*; hour occupant override, 10-hour backup ❑Not Observable ;t '`<_; ONot Applicable . •C408.2'.5:�; Furnished HVAC as-built drawings ❑Complies :1; ,',V ''':''a;°submitted within 90 days of system ❑Does Not [F17]3, acceptance. • z;, ; 1 ❑Not Observable , ONot Applicable C303C 34` Furnished O&M manuals for HVAC ❑Complies 082''.5:2:,= systems within 90 days of system ❑Does Not '[•F18]3, ;;- acceptance ['Not Observable P;•••?: ONot Applicable C408.2.5. ;An air and/or hydronic system ❑Complies 3 i balancing report is provided for HVAC ❑Does Not (Ft43]1 ;systems. i ['Not Observable ONot Applicable C408.2.3. HVAC control systems have been ❑Complies 2 tested to ensure proper operation, ❑Does Not [F110]' calibration and adjustment of controls. ❑Not Observable I ❑Not Applicable • C402.48-1 Recessed luminaires in thermal ❑Complies Requirement will be met. [F1210-,,,_;;:;:,'envelope to limit infiltration and be IC ❑Does Not "" ;,;�,. rated and labeled. Seal between "; :l. `'' interior finish and luminaire housing. [Not Observable <»;r;_• LJ Applicable 0403:2:2 ;' HVAC systems and equipment ❑Complies [F12T7;]3=" ;:capacity does not exceed calculated ODoes Not ?` ,•. rads ° :Not Observable ONot Applicable 1 High Impact(Tier 1) 2: Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title. Jernick Moving&Storage Report•date: 04/07/15 Data filename: •C:\Users\matthew\Documents\COMcheck\Jernick.cck Page 14 of 16 , . ,C4085'11FOrnished as-built drawings for []Complies ,iWN',,,y;:::electric power systems Within 30 days ODoes Not of system acceptance. [Not Observable (=Not Applicable cpq'a,,q•,4': Furnished O&M instructions for OComplies -08S.2:6''',24', systems and equipment'to the ODoes Not 1.E11,7T54,4', building owner or designated ['Not Observable r-,r-- --'— []NntApplicab|e C405.5.2 Interior in�aUedlamp and�xtura '[]compxes See mem��o unoungnv��scoedu�m,vames [p118]1 :lighting power is consistent with what Oooes Not . ;is shown on the approved |i lighting ' • Omot Observable � — - --'-'----'~|---osed|�wed--- []mot4p�ica�|e ave/esscnanv,equa to a . watts. C405.6.2 :Exterior isconsistentLJCom�ie= See mesx��o Lighting fixture,cnedummrvames ., [puy]zwith what is shown on the approved ODoes Not . lighting plansdemonstrating []motObsemab|e ;proposed watts are less than or equal ' to allowed watts. []m� t Applicable c408.2.1 'Commissioning [] pan�eve|oped by / comp|ies / [p|ao]z registered design professional or []ooesmvt ;approved agency ['Not Observable | ' Omotxpp|icab|e C408.2 4 Preliminary commissioning report '[]Complies [F|ze]z completed and certified by registered LJooesmnt , design professional or approved []motobsemab|e ' /agency ' | []motxpp|icab|e ' c408.2.5 Final commissioning report due to '[]Complies 4 building owner within 90 days of LJovesmot • [pou], receipt of certificate of occupancy . []motobsemab|e / []wctxppxcau|e ' [408.2.3. HVAC equipment has been tested to []complies 1 ensure proper operation. . LJooesmct [F13111 � LJwctmbsemab|e � • | Owotxppxcab|e . c408.3 Lighting systems have been tested to []Complies [p|as]z !ensure proper calibration,adjustment, LJooes Not programming, and , operation. []NotQbsemaWo ' []mot*mp|icab|e . C408.3us����,���u�n��m Ucomnx� � [F148]z i ensure proper calibration, adjustment. LJoneswct ;programming, and operation. []motousemame ' | []mot Applicable ' � '[]cvmpxes ' C406 � ' (F134)1 lighting system, or on-site supply of [Jouesmut renewable energy cOn-- 'with LJmctousemame what is shown the approved plans. []motApplicab|e . ^ Additional Comments/Assumptions: ` ' 1 High Impact �� Medium Impact 2) ��� �w|m���e 3) � , . Project TitleJernick Moving&ttorage Report date: 04/07/15 Data filename: c:\use,s\matthew\oncuments\coMcxecwdemickzck Page 15 of 16 , ` ` Project Title: Jernick Moving&Storage Report date: 04/07/15 Data filename: C:\Users\matthew\Documents\COMcheck\Jernick.cck Page 16 of 16 S FVEY . OF PROPERTY SITUATE 0-R H,ENPORT TOWN OF SOUTHOLD —7.3 SUFFOLK COUNTY, NEW YORK cc;NI S.C. TAX No. 1000—45--07-03 N w W U SCALE 1 "=30' 0 0 JANUARY 28, 2014 J 5 OCTOBER 14, 2014 REVISE PROP. BUILDING LOCATION NOVEMBER 4, 2014 ADD PROP. DRYWELL JANUARY 20, 2015 REVISE DRYWELLS AND ADD ADDITIONAL NOTES AREA = 51 ,534 sq. ft. 1 .183 ac. • I LSI 0 `r N/O/F VILLAGE OF GREENPORT 3 •N o O Z 0W 302.39' • �� N 89°41 '30" E m w vi m a m CONC. STOOP ° a o & STEPS ° EILG 44.6_ II-' CHAIN LINK FENCE L� % % % 1.2'S. FENCE 2.6'W. ° 0.9'S. —� —.—. 4. 0.7'E. ®E N 128.9' . . PROPOSED (2)8' DIA. X 2' DEEP 1'D It CONC. = O DRYWELLS FOR ROOF RUNOFF M • WITH GUTTER LEADERS 0 , W U = M Z O N. � 49 4 U TPI01 E ' J '^'_ 1 g� • z O ,� PROPOSED OFFICE a = o 0 � ADDITION u �" 110 � _ / W OWE W 44 cr, IA • i--: 10 N Wz0a sow O �U 1 STORY METAL BUILDING NW 2 z . %%S .;° ° oO ° ° e 29 91r N f ° J d UpZZ W a DRAIN GRATE 0 n UTILITY m 3 a POLE #4 LA zmm w I N ° ' 000 • ,• • o FENCE d4 lr<3J PROPOSED (2)8' DIA. X 2' DEEP �o�� • m o.s'w DRYWELLS FOR ROOF RUNOFF STOCKADE FENCE �a WITH GUTTER LEADERS° 4 ° I ' 1.11 4 ° aO ° I I - .I 128.9' .. f� 124.4' m 0 `t ' ZCi) 4 N ° ° ° ° ° ° 4 ° ° °��CONC. WALK 4 ° I °° ° m . -�y 1/�� O [�` ° 2 W 7 . ° e ° 4 ° e . 4e 4 ° V u/ \�^V 1:C 9 ° d e M I ° • Q O , 8 ^, 3 d ° ° ° ° e d ° 8 ° ° ° ° °d ° NI a 1° ° • ° 4 °° ° ° ASPHALT DRIVEWAY ° d °° 4° ° DRAIN GRATE ,°,� ° 2 44 O W d° ° 4 ° Qi a ° ° ° 4 ° ° ° ° 4e ° pp ° Z W 2 d ° e 4 ° ° °4 Imo, ° ° . B ° 4 e d o 4 ° ° FENCE ° 4 2 ° ° ° I 4 ° ° FENCE 4° 4 ° 2 2° 0.5'N. e ° 4 °4 ° ° FENCE 0.2'N. ' d ° ° / 0.1 N._0.6 E.- - - 4 ° ° ' ° 4 UTILITY '' 11 FOUND STOCKADE CHAIN LINK FENCE FENCE , FENCE °° POLE 3 0 PIPE 0.9'S.FENCE 0.5'S. 2.6'W. . •' 3 E2 I3 3058 LL, .73' l IA 6 1 ^O U U N/O/F a Z0. WILLIAM H. PRICE Z J U IX • BENSON Z_ O Q 0 2 IU O M BUILDING COVERAGE CALCULATION: EXISTING BUILDING: 16,061 sq. ft. (31 .2% OF LOT AREA) PROPOSED ADDITION: 1 ,140 sq. ft. (2.2% OF LOT AREA TOTAL: 17,201 sq. ft. (33.4% OF LOT AREA) SETBACK CALCULATION: AVERAGE FRONT SETBACK CALCULATION: (10.3' + 44.6' + 17.3') _ 3 = 24.1 ' PREPARED IN ACCORDANCE WITH THE MINIMUM W STANDARDS FOR TITLE SURVEYS AS ESTABLISHED ADDITION DRAINAGE SYSTEM CALCULATIONS: BY FFORTSUCH USE BYND APPROVED ORAND TALANDTE O q TITLE ASSOCIAT•• ," C; N ROOF AREA: 1 ,140 s ft. �4 Q �'`� •, Nt 1 ,860 sq. ft. X 0.17 = 194 cu. ft. a� -�A °_, 0 194 Cu. ft. / 42.2 = 5 vertical ft. of 8' dia. leaching pool required %5.$m �� t . 'ri z PROVIDE (4) 8' dia. X 2' high STORM DRAIN POOLS cc���� - �. c T� 1 TYPICAL STORMWATER UNIT Wit`--'' R 0 i T S T 1 d E i 1 (TOPS TO BE TRAFFIC BEARING) s p ' (N.Y.S. Rte. 25) (NOT TO SCALE) ` e CAST IRON FRAME & COVER (FLOCKHART #63516 TYPE 6840) - LAr N'. .S. Lic. No. 50467 GENERAL NOTES: FINISHED GRADE DR 6" THICK REINFORCED CONC. COVER 1. LANDSCAPING WILL BE ADDED TO THE SITE DURING THE CONSTRUCTION PHASE; AN AS-BUILT 8" TRAFFIC BEARING SLAB ' -1 i-D UNAUTHORIZED ALTERATION OR ADDITION LANDSCAPE PLAN IS TO BE SUBMITTED AND REVIEWED TO THE SATISFACTION OF THE PLANNING (max.) TO THIS SURVEY IS A VIOLATION OF a ■ BOARD PRIOR TO THE ISSUANCE OF A CERTIFICATION OF OCCUPANCY, P LI SECTION 7209 OF THE NEW YORK STATE Nathan Taft ®r in III 2. IN ORDER TO PROTECT AND PRESERVE THE QUALITY AND QUANTITY OF POTABLE WATER, PIPE FROM ROOF GUTTERS EDUCATION LAW. THE BOARD REQUIRED THE FOLLOWING: 8'.-0* COPIES OF THIS SURVEY MAP NOT BEARING �n a. ONLY THE USE OF ORGANIC FERTILIZERS WHERE THE WATER-SOLUBLE NITROGEN IS NO LEACHING RINGS THE LAND SURVEYOR'S INKED SEAL OR d Surveyor " MORE THAN 20% OF THE TOTAL NITROGEN IN THE MIXTURE. 3'-0' REINFORCED PRECASTDCSONC. 3' ' CRUSHED 3/4' — 1-1 z STONE EMBOSSED SEAL SHALL NOT BE CONSIDERED b. A MAXIMUM OF 1 lb. OF NITROGEN PER 1,000 SQUARE FEET ON ANY ONE APPLICATION, (min.) / TO BE A VALID TRUE COPY. 4"+ F(min.) ALL AROUND WITH A CUMULATIVE APPLICATION OF NO MORE THAN 2 lbs. PER 1,000 SQUARE FEET PER YEAR. CERTIFICATIONS INDICATED HEREON SHALL RUN c. PROHIBIT THE APPLICATION OF FERTILIZER PRODUCTS CONTAINING NITROGEN, PHOSPHOROUS o 4 ONLY TO THE PERSON FOR WHOM THE SURVEY Successor To: Stanley J. Isaksen, Jr. L.S. OR POTASSIUM BETWEEN NOVEMBER 1st AND APRIL 1st. 'E IS PREPARED, AND ON HIS BEHALF TO THE Joseph A. Ingegno L.S. d. PROHIBIT THE USE OF PHOSPHORUS CONTAINING LAWN FERTILIZER UNLESS ESTABLISHING `�l" TITLE COMPANY, GOVERNMENTAL AGENCY AND A NEW LAWN OR SOIL TESTS SHOW THAT THE LAWN DOES NOT HAVE ENOUGH PHOSPHORUS. GROUND WATER LENDING INSTITUTION LISTED HEREON, AND Title Surveys - Subdivisions - Site Plans - Construction Layout FERTILIZER LABELS HAVE THREE BOLD NUMBERS. THE NUMBER IN THE MIDDLE IS THE PERCENTAGE TO THE ASSIGNEES OF THE LENDING INSTI- PHOSPHORUS IN THE PRODUCT, e.g. 22-0-15. USE OF PRODUCTS WITH 0.67 IN THE MIDDLE OR INSTI- TUTION. CERTIFICATIONS ARE NOT TRANSFERABLE; PHONE (631)727-2090 Fax (631)727-1727 OR LOWER IS NOT RESTRICTED. PRODUCTS WITH A NUMBER HIGHER THAN 0.67 MAY ONLY BE USED IF A NEW LAWN IS BEING ESTABLISHED OR A SOIL TEST INDICATES IT IS NECESSARY. THE EXISTENCE OF RIGHTS OF WAY OFFICES LOCATED AT MAILING ADDRESS AND/OR EASEMENTS OF RECORD, IF 1586 Main'I Road P.O. Box 16 ANY, NOT SHOWN ARE NOT GUARANTEED. Jamesport, New York 11947 Jamesport, New York 11947 CZ w 0, 01Z Q Z m tn 0 N .. N cri n Lij z < a_ ez O O o H 0 z co CD w C) U) EXISTING WAREHOUSE BUILDING - FOUNDATION WALL, FOOTINGS SLAB $ SILLS ALL TO REMAIN 0 4-30 i_ - PROV. EPDXIED#4 STEEL o Q REBAR VERT. @ 12" O.C. SECTION:� f INTO FOUNDATION WALL$ 7 A / Z STEPPED FOOTING ABUTTING O O (TYPICAL ALL CHEEK WALLS, U NEW FOUNDATION WALL LOCATIONS) D m cz o .Y i . . . . . T 0 co Z O f 4'_2" } L ..,'-.." \ \ U - 1—Q L N O H8" POURED CONCRETE FOUNDATION o WALL STEPPED BACK FROM EXISTING { ` ` OSLAB; POUR NEW SLAB ABUTTING TO ._ 1 4 2 a U ;UNEXCAVATED,o• EXISTING .-"•7 DATEF POURED CONCRETE r�<l �_ !� ENTRY STOOP F,._.. J)i.... , _ : 1)1 .•1 .. . . • ... w Ln 0 • ` FOUNDATION WALL LEGEND: i! `" " ':.. . L' z o o EG ND: f:. U t.-h_ 1 EXISTING FOUNDATION WALL TO REMAIN ::, , z PROVIDE BRIDGING — • °' '` v — @� NEXCAVATED.f: 8" POURED CONCRETE Lf POURED CONCRETE _ THROUGHOUT ENTIRE • FOUNDATION WALL W/ ` "' i W z FLOOR SYSTEM, 8' 0" O.C.; �' ,;::.;� •..-I,:_�, OZ — ENTRY STOOP CRAWL SPACE z u- I -4 Y.5" d. FTG.; PROV. " TSG PLYWOOD SHEATHING 2- #4 REBAR IN FOOTING. 4. ;';i.'.'.. - +_.`.:: •'•;;''',' " '' J co— i" _ E, ABOVE, GLUED $ SCREWED 4" POURED CONCRETE SLAB DAMP'PROOF PERIMETER , C ... ._,; .__ u ON COMPACTED FILL WITH OF FOUNDATION WALL i I_ '"''';' {` ,r "t ', N/ o: W.W.M. 6 X 6/ 1 0 X 10 o (TYPICAL ALL AREAS) .) i tl- i l'' • GAUGE WIRE ;= Fi .l is";; ;_..i 1, i. v �-- z L VO • n-'., ,..) r: :=_ O R-19 INSULATION THRU-OUT U -• I_.. P'_;f i U WINDOW WELL AS - `'! !: CO..;. (i it C i lC;d F f;; (?!� i, z r , co Q �l z NEEDED FOR GRADE - z Z f ^ o � ' P• PROVIDE SIMPSON PHDS C.."=7 7-i "o�. '°(','l'^.0 O v o' HOLDDOWN . 2 ! CODES T1 09) — ANCHORS AT ALL CORNERS NL Y', THROUGHOUT ,-•,ONDiT ON W AS r� culR � �r' � 'ty� � � I . OF LI PROVIDE VENTS .5 DIAMETER ANCHOR BOLTS 6 IN FOUNDATION A W/7" MIN. DEPTH @ 45" O.C. f S�'d" ;' .,'',^- ,',;;�,'': E'3ARD SECTION' xg REQUIRED BY CODE W/ MIN. 3"X3" " WASHER @ PLATE TI _,��._w Y 25'-0" , 60,_0 ....._._.. .a�-... , , a_. . ..�. Ii .d FRONT ELEV. U 0 PROPOSED FLOOR PLAN , z o > cO zJ 7' SCALE: 4 = I '-O" Z cn U (1-' cp < zin � .- O n U (1---6I � -) JSZ ?U sA.0 W OF NEW ® .c�4' ��N,.IAAgt. -s, CliENG1j°': * �#1/4#4 1/4, , ...,4• ,,,,,,,i„ . A 08358A� 8358 4, PAGE: "0FESSI0N� 3 . 17 . 15 4- "UNAUTHORIZED ALTERATION OR ADDITION TO TMS DRAWING AND RELATED DOCUMENTS ISA VIOLATION OF SEC. 7209 OF THE N.Y.S. EDUCATION LAW" CZ LLJ a >- o z < z 5.: co U•) c> O ill 0 cn ILI, I-- Z (I) < I 0 < z D-- < iL r CZ L.) 0 1 E 0 U_J 0 — z ___.1 O - U-. a I-- • (I) 0 0 Lt.,' Z CO N ni . — LOU') <, •• . i EXISTING WAREHOUSE $ STORAGE ALL TO REMAIN < u, I 6,060 sci.ft.; S I Classification EXISTING WAREHOUSE BAYS — TO REMAIN, INCLUDING ALL DOORS, OVERHEAD DOORS, INTERIOR, PARTITIONS RESTROOM EXISTING STEEL FRAME FIRE RATING * CONSTRUCTION TO EXISTING WALLS $ ROOF STRUCTURE. — BE WITHIN STRICT ACCORDANCE OF c7 /- FIRE WALL TO BE CONSTRUCTED CHAPTER 7 of_LtE.Jr-Y- /-. --6 mimmum miromum WITHIN EXISTING BUILDING. WALL SECTION 1, A , ,c0--010 'IV(LANi- 7z r.... < .9- 0 TO EXTEND FROM FOUNDATION YNk Or7 ---p. - TO ROOF ASSEMBLY AND A MIN. OCtSt.--' Oist ..,_ O 0 OF I 5'-0" BEYOND SIDES OF ACCESSIBILITY SHOWN TO COMPLY i"---- PROPOSED NEW ADDITION w/THE ICC ANC, A117.1-2003 EXISTING STEEL FRAME WALL 0 q•4) REGULATIONS STRUCTURE TO REMAIN Id D rz v • 0; -•iir___ 4 SIDE I-`• 4-' t - -------------- --- ------ - FIRE RATED L 1 -94,ELEV. (r) (I) >•- _--7 -bi- b 1 2 0 E 0 co 4-2" .',S / FRIDGE CABINETS$ / ei IL -_,4M13 4 COUNTERTOP / 4065 4065 I /' 0 0 11: 25'-0" "I 1 1'2" // / ----/, 7-Vt RTICAL7 9'-10" \ gipAss ;, EMPLOYEE $ 2 b ill) 0 RAMP DOOR TO HAVE SELF / hORIZONT/mERGENcy ALAF,Iii_ P 39'7"+/- /- 1—CLOSING HINGES / ' BOTH VISIBLE 4 A DI:r i ENTRY A (i) t 1- / / 3065 / A WALL LEGEND: F- E 0 fm0 M DOWN zi 4 PANIC HARDWARE / / / CLOSET/,CLOSET A s._ (0 •-... 4) '-• 0 I- 12 < n BATHROOM -- i / ro WALL TO REMAIN 0 1 ' A PRIVATE OFFICE / / / / .-'1 Z ENTRY STOOPA'Z' 1 / DOOR TO HAVE SELF q NEW CONSTRUCTION , / //.so 6 iwA rm 4 mA rem /AM% .ern. mA tili FA e liwA r / A m F.mA a / 0 / -1/ /- - CLOSING HINGES I FIRE WALL SEPARATION: VERIFY LENGTH IN - < DOWN \3170 0 1LAYERF5-" FIRE RATED DRYlvVALL * PANIC HARDWARE * A 4-6" 17-7r:::§ 2"X 4" STUD FRAME AGAINST EXISTING ROOF CONSTRUCTION: FIELD TO GRADE lth. Lo, 0. . • STEEL SIDING WITH 3 LAYERS i" FIRE RATED PLYVVOOD SHEATHING WITH LLI u.) . ON CEILING; PROVIDE BRIDGING § 4 Z =--1, 0 THRU-OUT ENTIRE CEILING * GYPSUM BOARD TO NEW FINISHED SIDE ice * WEATHER SHIELD @ 0 $ . 45 i- = Lo ..; - - , - = SYSTEM, .5',-CY 0.C.; <s) • il ENTRY STOOP PERIMETERS; EPDM MEMBRANE • N.i. - . in (-) .,I, -----1 0 % - . "MG PLYVVOOD SHEATHING - b _ . 2"X 4" STUD FRAME EXTERIOR WALLS UNERLAYMENT 0 • ...,..,@.) - cii • "'** * R-15 INSULATION W/i" PLYWOOD Z .. / I ts) 0 0/ . ,----, . , , ., ABOVE, GLUED *SCREWED; 17 "6 RECEPTION DOWN RUNOFF NOTE: -:: - d R-30 INSULATION / i:-.:11- > SHEATHING, 56" FIRE RATED GYPSUM BOARD --). 41.0 Gutters continuously around; i 29 (3 --c._ .›- --e___ ____-- -c, _.›- / / ___ - g ON INTERIOR SIDE; TYVEK WRAP It Leader locations as per Oil / r.7.1.,- ,„ 1 _ / ,///:0- P z , - / H 4 HARDIE PLANK LAP SIDING installer -all leaders drain to r4 rol - g / i 1 >, - z U 6" 0 PVC pipe to new drywells. Z 1.`;',/, F --; / / 1 MEETING AR.EA4 >1 / / 0 0 //,/,/// 2"X 4" STUD FRAME INTERIOR RUNOFF CALCULATIONS: I. 4 ir...4 '.: I z (.3 / / / PARTITION; LAYER " GYPSUM BOARD \/ i''' ON EACH SIDE New Roof Area = 1140 sl.ft Z / 1 . / Ns/ x .167 x 7.5 = 1427 gallons ril gi i / -s--- 7, ..c-- , A-- , 12 / Requires - (2) 2'-0"X 8I-0"0 rings / / —11 PROVIDE 2- I i"X Si" LVL HEADERS Z Cf) Nt- / 'c Z 17, PROPOSED NEW OffffICE 0 7 / / ' '-! '--' `-' `-, C.--........ =- .-'---, ://' / o - 1- ABOVE ALL WINDOWS 4 DOORS UNLESS OTHERWISE NOTED; 7'-O" 0 11 40 sci.ft.; B Classification / / / \ „'/ 1 0-0” 81- -RAMP-- VERIFY LENGTH IN HEADER HEIGHT ABOVE NEW FLOOR C4 0 / • /, W ce Occupancy: I I 40s,f.@ 100 = 11 .4 ppl % / / FIELD TO GRADE TYPE512 Construction rating ;,,,c,,, - ;AP_ WSW I WAX%, (*NO:...420.),X•Wi.,x.4.X.:(44:4"...o.w.COMC•:•21 ,,,. ;,.. ...),...,„,,me c....;„,*Am, - ------ = - = _L >' .. .t.:,.',..• ......, . ... ',_%11 -------1--- ..'/ '..• • ^A" •• ,,,?&M,M, ,,,%,< >,. •" • .A t,-------- l'W<, ,,q,>7.,,177-k EXIT SIGN WITH Cn cxwi 4 w/AR3 I CXW I 4 w/AR3 I PG040 w/AR3 I-2 CXW I 4 w/AR3 1 CXVV I 4 w/AR3 I H EXIT I-- EMERGENCY LIGHT $ AUDIBLE 4. H'M I_ EMERGENCY LIGHT SECTION'L, / GV-0" / A K ,,, : ‘ C.0:. ,,, A_' z..,_ _...k, •-v 1 24-7" A-- 1 FRONT ELEV. 0 z FROPOSED FLOOR FLAN z SCALE: :41-" = I '-0" V _ H ___1 0 D n co z ti) o (7) u Z . CD -v - ,(-) . n UJ t • z CZ 1 --/....--- .."----__ (Th . 41 4191. >-- \ :..-- 0 --- Z__-- , < (.1 In\ \j ',..it JUL - 1 201,5 \\-:i PAGE: "UNAUTHORIZED ALTERATION OR ADDITION TO THIS DRAWING AND RELATED DOCUMENTS IS A VIOLATION OF SEC. 7209 Of THE N.Y.5. EDUCATION LAW" 39 (0 /5 . W Jernick , ortz oss SQ�G svQco 1 4:)%' \N S-\''il tSS) - __ ___ _ ck*,,O. te,,4 S!OZ Q - u d V 17- !! a) o_. N89°4 I '30"E 302 . 39' E— OO —44'-7"- . Q / / I. h' , l'i i. ' ; ': ' k , ,,, 1.11 o OUTLINE OF SIDE $ BEAR I-- NO;I, s .f:•. '_ o N YARD SETBACK REQUIREMENTS F01.1.1:''';!;!:. : ;'I` ; _ O y .i r V U r 1 1' ', IO'; Q LU 4. -, y, „ I9'-O" - -2 6' N O 0 �«i_ �s.�il�leJi� ��i✓lll�:J -•�'1,'! I ;`� [. i ii!�' r'llIE COrS,E3 OF NMI PROPOSED ♦ ♦♦♦♦♦♦ YO` :niT;',TC. NOT FtJi3r) I''1'r_ I syli in ♦'� NEW OFFICE �� �� DESIGN ORc :_ �cflt ;� ERRORS. O ����� N ♦���♦ ,if_',':', '' ' iiE OF .♦♦♦♦ ✓_ . C ZBAz 1 _..../......._SOUTri',OI.0 TO;°':I PLANNING BOARD U °' O ♦i♦i♦i♦# , O T u m Q EXISTING CONCRETE OCCUPANCY OR Z Lo , EXISTING KETAL BUILDING �, WALKWAY ����� TO REMAIN N USE IS UNLAWFUL Q �' rn O : .• . .. ' . . ' WITHOUT CERTIFICATE W # OF OCCUPANCY / , O O PLUMBER CERTIFICATION Z ♦�♦�♦♦'�♦ ON LEAD CONTENT BEFORE — u > : : ♦♦♦♦♦ CERTIFICATE OF OCCUPANCY U SOLDER USED IN WATER o -----29'-7 I/2" ---�--� � . . • Z SUPPLY SYSTEM CANNOT EXCEED 2/10 OF 1%LEAD. ENTRY PLUMBING U0 ALL PLUMBING WASTE Z U N &WATER LINES NEED Q z + TESTING BEFORE COVERING Z Z o • In r I J , m ,^ O v ) us W . ELECTRICAL I) MISPECTIONR tLY" r - Ln. RETAIN STORM WATER RUNOFF 6� PURSUANT TO CHAPTER 236 C9 CY) / . OF THE TOWN CODE, O N 1281- I I " 0 n LU � 0 N to d- zU > o � O O � z o > m di" 0 wJ TS � CV (n zc� U m °3. Q zE — O "' czc0 CV QUO � L.0 LLJ 0 (I� n43,- � v ® \Duis ?_ s .,, _______ J 4,0. ,, S89°33'30"W 305 . 73' T. er3 .<•' ' ,,� JA,.t(,�- -0,, ® ENG 1 �1• _..,. a �D . C PAGE: \..0 03358 < 4 . 07 . 15 1 "UNAUTHORIZED ALTERATION OR ADDITION TO THIS DRAWING AND RELATED DOCUMENTS ISA VIOLATION OF SEC. 7209 OF THE N.Y.S. EDUCATION LAW' w D U z Q EXI5TING PIDGE HEIGHT m EXISTING METAL BUILDING- — Ln - - O N E(ISTING WALL PLATE III MIIIIIMIIMIIIII , I I I I I I� `� . . . D O T VE RAIL W II — CINTI000S AROUND JERNICK cn Q I II II FL T Rn'OF Moving Storage z o - NEW RO�F STRUCTURE— I ) 11_ ( 1 1 rI I 1 I N }--[ •-a —._:—: 1 II 11 I CEILING/PLATE HEIGHT 1 10 EXISTING METAL BUILDING i GL j /, / /^ % EW � j� � j� / / NO FICW�ADODDITION FRAME W CV C CXW%' PG040 ��,,,/2 OW✓�' W V / W te Sx % I I- o __________________--„f \ �nzs I \ CRs \I�AR� \' PR, \ 3 ti NEW FLOOR 12 Q O RAMP BALI;EGRESS CD ulj GRADE E ' t VERIFY LENGTH IN Q FIELD TO GRADE CO NEW OFFICE ENTRY • FOOTING DEPTH ' ' '— NEW CONSTRUCTION FRONT ELEVATION - FACES MOORE'S LANE I SCALE: 16" = I'-0" O Q NEW CONSTRUCTION °' z " O o 1 U °'' Ir o z * O 2' Ur z ' ll O L n -6 O Q s _co Oco v CV f 1 f 1 f l ♦ - 7 -, U 1.i\ 7/ 7 ' z / ., `0 CZ CD c9 in I/ cxw LL_1 Lo — — AR3I N _ r- --1 cJ('1 • _ — z • O ) U 0 ›- _ RAMP I z U z I z z o U n us LEFT SIDE ELEVATION - NOTh "J 0 SCALE: 4" = 1 ,-0" NEW CONSTRUCTION I I CD 0 _z • �N U N co N _ �z0 > 03W \ z > CO oI ) r ! 11 n� EXISTING METAL BUILDING nITO REMAIN z --- D z U N-1•11ernick Office- Q z in 11// Z dJ L PC040 /� / / \ HANDRAILS BOTH r ' - �J SIDES _ L I 12 Ir— — ® DKI`L 7 o RAMP �S U t.) - ��� VERIFY LENGTH INI 1 U FIELD TO GRADE W U 1C) N ,1/1-7; '' e 4,, WAJ Ah iiti ® ENG 1°'� RIGhT SIDE ELEVATION - SOUTH irrtSCALE: „ = I'o° ••. -�•=.►wr PAGE: iv 4 . 07 .-15 2 UNAUTHORIZED ALTERATION OR ADDITION TO THIS DRAWING AND RELATED DOCUMENTS 15A VIOLATION OF SEC. 7209 OF THE N.Y.S. EDUCATION LAW' cz w U z - Q z >- co • in 0 N dt (n (+ J W 7 Q < 0 J a_ cZ . 0 0 J Ll._ o H 0 z Q EXISTING WAREHOUSE $ STORAGE 0 ALL TO REMAIN Q 16,060 scl•.ft.; S I ClasslfIcatIOn EXISTING WAREHOUSE BAYS TO REMAIN, INCLUDING ALL DOORS, OVERHEAD DOORS, INTERIOR, PARTITIONS RESTROOM EXISTING STEEL FRAME FIRE RATING $ CONSTRUCTION TO EXISTING WALLS * ROOF STRUCTURE. BE WITHIN STRICT ACCORDANCE OF o 1, Is'-0" / FIRE WALL TO BE CONSTRUCTED '• CHAPTER 7 � � Is-o" MINIMUM MINIMUM WITHIN EXISTING BUILDING. WALL 7FAON j r" r" 'tom' - 'Oi d K.')0..\-- � `= L - TO EXTEND FROM FOUNDATION / �j' IQ`�`? U TO ROOF ASSEMBLY ANDA MIN. Z O 0 OF 15'-0" BEYOND SIDES OF ACCESSIBILITY SHOWN TO COMPLY PROPOSED NEW ADDITION w/THE ICC ANC, A117. 1-2003 EXISTING STEEL FRAME WALL REGULATIONS STRUCTURE TO REMAIN 2 I cZ o _v C 3O/O; 3HU FIRE RATED L �•.ELEV.4 SIDE I— � } Z 1.1 FRIDGE _ �1 p 109M5 e . O4-2" CABINETS $ [C] 01:1 jji 0 i 2s_o" - ��, x0685 4o Z `` / • BATHROOM ` EMPLOYEE U 7008 TO NAVE SELF \ ✓ I 3068 0 I '� 39'-7"+l- / a RAMP CLOSING HINGES ✓ `_ ENTRY o D &, ✓ II - - •• WALL LEGEND: h- E QJ 0 C/ v DOWN $ PANIC HARDWARE ORIZ0 TAL I, CLOSET Q L H 1 12 s ERTICAL EMERGENCY ALA ' I o • - O O 1 PRIVATE OFFICE o � BKTH VISIBLE $'AUDIBLE / .- WALL TO REMAIN O ENTRY STOOP ✓ r II � DOOR TO HAVE SELF i NEW CONSTRUCTION 1 0 in O ✓iii iiiiiiiiiiiiiiiiiiiiiiiiurii/� F, """4 CLOSING HINGES FIRE WALL SEPARATION U - I A/. I LAYER i" FIRE RATED DR TALL 4'6° �� _ „ VERIFY LENGTH IN 307 F = 0 �� PANIC HARDWARE ....., 2 X 4 STUD FRAME AGAINST EXISTING ROOF CONSTRUCTION: DOWN �_ ON CEILING; PROVIDE BRIDGING W FIELD TO GRADE �� THRU OUT ENTIRE CEILING I ® \ \ STEEL SIDING WITH 3 LAYERS g" FIRE RATED " PLYWOOD SHEATHING WITH Z - • m SYSTEM, 8'-0" O.C.; GYPSUM BOARD TO NEW FINISHED SIDE ICE WEATHER SHIELD @ 3068 w -' ENTRY STOOP PERIMETERS; EPDM MEMBRANE .® TSG PLYWOOD SHEATHING U 0.N z U ABOVE. GLUED SCPEWEAt• N Ln_ p0 o tires` 2"X 4" STUD FRAME EXTERIOR WALLS UNERLAYMENTZ O ie'iiiiiiiiiiii.111W iiiiiiiii vi - X - • ..a it•-: R-15 INSULATION W/,i" PLYWOOD — t• a I in Lj 2868 . _, , ,_ R-3-04NaULATION 0 1- RECEPTION w DOWN 4 RUNOFF NOTE: - O //j / ^ �"— 3� ` SHEATHING, " FIRE RATED GYPSUM BOARD Gutters continuously around; iMi ON INTERIOR SIDE; TYVEK WRAP • -c �- y - dU Leader locations as per U HARDIE PLANK LAP SIDING Z U g 1,01 _ - w installer all leaders drain to PRIVATE OFFICE { ,, z U 0" 0 PVC pipe to new drywells. W — 0 2"X 4" STUD FRAME INTERIOR F— o MEETING AREA D "/�///✓ PARTITION; LAYER GYPSUM BOARD \ / $ I z v [ ® LA aa, yy�� RUNOFF CALCULATIONS: _l c,� �/ - { y Q �h❑ ON EACH SIDE New Roof Area = I 140 sq.ft a• '{ 0 0 b x . 107 x 7.5 = 1427 gallons ,f� • - , �c , .c , ,c -x 1 2 v 1 3 —I I PROVIDE 2- 13i X Si" LVL HEADERS Requires (2) 2' 0"X 8' O"� rings Z - { Y Y = _, f .- 'M' OM a_ ABOVE ALL WINDOWS $ DOORS U O PROPOSED NE'W OFFICE . { r _ = o_RAMP UNLESS OTHERWISE NOTED; 7'-0" z III U 1140 sci.ft.; B Clssificatlon *ilI1r VERIFY LENGTH IN HEADER HEIGHT ABOVE NEW FLOOR Q z Occupancy: 1140s.f.@ 100 = I I .4 ppl 0I 4-4 FIELD TO GRADE f•.r . v J L s; c..J --5 oma•• •r'•• l'•4+:'n•: til o:vw✓-: mm r' r' r:• w:❖ ••i5•.•.•-r' :r• � II:�:+Sa-��Y'.s�..fislriti4�'SCti::'_ :ti 2� . . ti ..•.✓3.. �w.sr.....rl��l..............•...�r�.r}�:�.o,'�i.�fi.A�.23�....�:�:.e.::•'..1 Y . .•:+�1.'�r'r.:�+�1 1�J.e2...: � �:?ANtiti:.�.'�"��:..•"s+:�►.Z ?:�a1�1i1�+6:�*�: ....•aS; EXIT SIGN WITH TYPE 5b Construction rating �.r ��..r :tir:l IA:�i. ..�3a� h3�' �''�.•ye. CXW 14 w/AR3 I CXW 14 w/AR3 I P6040 w/AR3 I-2 CXW 14 w/AR3 I CXW 14 w/AR3 I H EXIT -EMERGEI!CY LIGHT CR $ AUDIBLE W ,, H /SAH EMERGENCY LIGhT L SECTION' 60.0" / A 124'-7" FRONT ELEV. 1 U 0 PROPOSED FLOOR PLAN W °- - o03 I.. U z o > CO SCALE: 4 = 1 -0 Z Z (U O - co. Qz r = -= O ti--_-; L s U ® DNI,L7 - C,,,) li's 0 ,--)F=77T .% W CO , .5, ENG 1�� ' vidi ' .."740e.evi.\ ,,,,, c X80 PAGE: 4 . 07 . 15 3 "UNAUTHORIZED ALTERATION OR ADDITION TO THIS DRAWING AND RELATED DOCUMENTS ISA VIOLATION OF SEC. 7209 OF THE N.Y.S. EDUCATION LAW' CZ w n U z Q z 52- co in N z < a a- OZ 0 0 u_ W 0 z CD w EXISTING WAREHOUSE BUILDING - Ci O FOUNDATION WALL, FOOTINGS SLAB $ SILLS ALL TO REMAIN 0 4-30 4 PROV. EPDXIED #4 STEEL L Q REBAR VERT. @ 12" O.C. SECTION•' v / INTO FOUNDATION WALL$ A / Z STEPPED FOOTING ABUTTING 0 O (TYPICAL ALL CHEEK WALLS, U °' NEW FOUNDATION WALL LOCATIONS) S CZ 0 (I) )- Z '3- O6' — . — . — . — . — . — . — . U Z m O \ "POURED CONCRETE OZ ENTRY STOOP $ RAMP 8" POURED CONCRETE FOUNDATION z JNEXCAVP,TE� UTILITIES - WALL STEPPED BACK FROM EXISTING O GAS FIRED FORCED SLAB; POUR NEW SLAB ABUTTING TO r 4'-2" / AIR EXISTING ;p:, p 0, POURED CONCRETE SD ENTRY STOOP z L• - O o ` FOUNDATION WALL LEGEND: Imo' �ib� u-�Lo U y' EXISTING FOUNDATION Z O WALL TO REMAIN ', z w PROVIDE BRIDGING — THROUGHOUT ENTIRE UNEXCAVATED.:: 8" POURED CONCRETE w - FOUNDATION WALL W/ W Z LO FLOOR SYSTEM, 8'-0" O,C.; CRAWL SPACE z w — — I'-4"X 8" d. FTG.; PROV. _ .. J 4"TSG PLYWOOD SHEATHING 2- #4 REBAR IN FOOTING. J 0) w ABOVE, GLUED $ SCREWED 4" POURED CONCRETE SLAB DAMP PROOF PERIMETER / so:,,. - ON COMPACTED FILL WITH W.W.M. 6X C/ 1 0 X 10 OF FOUNDATION WALL ,^ \ WINDOW WELL AS • mo (I) %a'` (TYPICAL ALL AREAS) v 1 NEEDED FOR GRADE w \ GAUGE WIRE £ Z p U R-19 INSULATION ThRU-OUT U 0 3 \ Z U Lo Q z N Of -77 coZ rrZ�� o 'P' .?' PROVIDE SIMPSON PHD5 V— +.i' .. HOLDDOWN TYP. 2) ANCHORS AT ALL CORNER W THROUGHOUT Q PROVIDE VENTS a DIAMETER ANCHOR BOLTS ►. IN FOUNDATION AS W/7" MIN. DEPTH @ 48" O.C. SECTION I, REQUIRED BY CODE W/ MIN. 3"X3"x8" WASHER @ PLATE A / 25'_0" / / 60:-0" FRONT ELEV. O O • WU N0OCV PROPOSED FLOOR PLAN z = ' c' 0 ztu � 7m SCALE: 4 - I -0 �,Qil � zc(nU Qz � 7 —= OZ ( U O n Z s U) U 1(4) U DslI0 (24 NEt>r W -cc- Cr3 4 * #p . * ® ENG1 - W 7.s " f 35S '' q Fit" PAGE: 4 . 07 . 15 4 "UNAUTHORIZED ALTERATION OR ADDITION TO THIS DRAWING AND RELATED DOCUMENTS 15A VIOLATION OF SEC. 7209 OF TIE N.Y,S, EDUCATION LAW" EXISTING RIDGE HEIGHT w NAILING SCHEDULE . . , . , , . JOINT DESCRIPTION NAIL QUALITY NAIL SPACING 4"x 4" POSTS WITH BASE $ CAP; Z DECORATIVE RAILING- 4" z 2"X 2" BALUSTERS BETWEEN z ROOF FRAMING . ,.. ... . .. .._ ~, ., ...... .... ... ' RAFTER TO TOP PLATE TOE NAILED 5.-0' ' - f PER RAFTERin • • 4-561 PER RAFTER PROVIDE EPDM MEMBRANE ~ , .. ~ . . y 4 SCUPPER CEILING JOIST TO TOP PLATE TOE NAILED • PER JOIST DRAIN SYSTEM 2 2 X 6 END RIM z UNDERLAYMENT r I� �► • a PER JOIST EXISTING STEEL FRAME ... .. . . . , .. .. , _, , _, BUILDING TO — CEILING JOIST TO PARALLEL RAFTER FACE NAILED TABLE EACH LAP MORTON . . ., . . ..,..., . , ,.. . _...~ . ... , . ~. REMAIN 4 BEDMOULD CEILING JOIST LAPS OVER PARTITIONS FACE NAILED ' EACH LAP - SCI EXTEND , . COLLAR TIE TO RAFTER FACE NAILED TABLE PER TIE - -_, z BELOW FACE OF SOFFIT •, •( •' I"X 12" AZEK FASCIA; < O _,_,.___-_F- BLOCKING TO RAFTER TOE NAILED EACH END — LEAD COATED COPPER CONTINUOUS 2" STRIP VENT RIM, BOARD TO RAFTER END NAILED -• EACH END EXISTING STEEL FRAME FLASHING OVER EPDM, I'-0" _ SEE DETAIL°A" CEILING _ APPROVED EO, JOISTS BY CORA OR APER - - - • WALLS � ROOF STRUCTURE. UP WALL $ OVER ROOF AREA i 0,' V J +,......~.,... FIRE WALL TO BE CONSTRUCTED 2"X 3" BLOCKING w WALL FRAMING .. ._ ..., .... . ... . ...... .. .... WITHIN EXISTING BUILDING. WALL I + i„ / ry' p TOP PLATE TO TOP PLATE FACE NAILED 2 i Gd PER FOOT -_-__ NEW Roof STRUCTURE 2 INTERIORLL SIDE.. .. , . ,, ..,_ ..~..., .~~... ..... ... .. .. ... . .. IN N S E I X 8' AZEK FREIZE FACE NAILED 4-I Cd JOINTS- EACH SIDE TO ROOF ASSEMBLY ANDA FOUNDATION I I i" TJI 560 C.J. @ I C" 0,C, R_30 11111 WITH CROWN MOULDOAGRD TOP PLATES AT INTERSECTIONS F~_ .,,,.~...... .. ..... ... 15' O' HILI \ 1 v OF BEYOND SIDES OF STUD TO STUD FACE NAILED 2-1 6d 24 ©/C, .....~,..~ ..„ , „, . PROPOSED NEW ADDITION CEILING/PLATE HEIGHT HEADER TO HEADER FACE NAILED 1 6d 1 6"0/C ALONG EDGES OVER I X 2 TOP OR BC+t 1 CM PLATE T O STUD- END NAILED' 2-1.6e- PER.' 2X4 STUDH Ii 3-16d PER 2X6 STUD BOARD, YP ALL AREASN g FIRE RATED GYPSUM 2 I i"X 9 �" HEADER ABOVE r l �D, T ALL WINDOWS AND DOORS; U . . ,. PLATE TO FLOOR JOIST, 4-. 6d PER 2X8 STUD PROVIDE CS20 STRAPPING OFFICE LLJ 2"X 4" STUD WALL @ BATHR M HALL OFFICE 16 O.C. W/ R-1 5 INSULATION BANDJOIST, END JOIST, OR BLOCKING FACE NAILED 2-I Gd ' — PER FOOT - • ° -4 X PLYWD SHEATHINGa 2"X 4" STUD WALL @ EK' HOUSE WRAF' S I 6" \ X 4" INTERIORWIHARDIE FLANK LAP SIDING FLOOR FRAMING P , ,. ... .......,.. .. . .. 2��X 1 2" AC 4'TYVEK' 2" INSULATION ION , D SHEATHING < JOIST TO SILL, TOP PLATE, OR GIRDER TOE NAILED 4-8d PER JOIST 2" DRYWALL ON EACH Q LEDGER AGAINST w EXISTING STRUCTURE; BOLT w/ YW W/ HOUSE WRAP � r (� HARDIE PLANK LAP SIDING CJ BRIDGING TO JOIST TOE NAILED 2-8d EACH END OC SON HU SERIES SIDE BLOCKING TO JOIST TOE NAILED 2-8d EACH END $ HANG JOISTS w/TECOS CONNECTOR @ JOISTS/LEDGER 5" LEDGERLOK SCREWS 16" USE SIM Q .., . . , . , , , . .. . .,.. _ . • 2- 2"X 6" ACO SILL PLATE / U BLOCKING TO SILL OR TOP PLATE TOE NAILED 3-I Gd EACH BLOCK F J @ 16 O C SHEILD . " , ' - ' NEW I - TJI 560 = 11' OVER TERIMITE NEW FLOOR LEDGER STRIP TO BEAM FACE NAILED 3-1 Gd EACH JOIST a 0 " IIleyt I OVER SILL SEAL; JOIST ON LEDGER TO BEAM TOE NAILED 3-8d PER JOIST •� R-1 9 INSULATION / LPT4 CONNECTORS GRADE PROVIDE IMP N C 2 BAND JOIST TO JOIST END NAILED 3-1 6d PER JOIST / CRAWL SPACE , .. SILL EXISTING 4 s.. BAND JOIST TO SILL OR.TOP PLATE TOE NAILED 2'1 Gd PER FOOT e/ 7" 4BOLAIL "A" DIAMETER ANCHORDETAIL EXTERIOR WALL \ W MIN. DEPTH @O.C.. m STRUCTURE TO REMAINW/ MIN 3"X3"x8"WA ROOF SHEATHING • NEW FOUNDATION WALL POURED CONCRETE SLAB I F I - SHE @ PL " = I ' O" nil\ R AT FOOTING DEPTH STRUCTURAL PANELS CONTINUE SLAB TO STEPPED OFF EXISTING SCALE: 2 4' PERIMETER EDGE ZONE - I C"0/C- C. AT PANEL EDGES NEW FOUNDATION WALL STRUCTURE \ NEW 8" POURED CONCRETE FOUNDATION WALL WI o AND AT INTERMEDIATE SUPPORTS IN THE PANEL FIELD I'-4"X 8" d. FTG„ PROV. INTERIOR ZONE - 16"0/C - C"AT PANEL EDGES AND I 2"AT 2- #4 REBAR IN FOOTING L Q .. INTERMEDIATE SUPPORTS IN THE PANEL FIELD BUILDINGSECTION IIAII (TYPICAL ALL AREAS) FOR ROOF SHEATHING WITHIN 4'-0"OF THE PERIMETER EDGE OF THE ROOF, INCLUDING 4'-0''ON EACH SIDE OF THE ROOF PEAT;, THE 4'-©"PERIMETER z v "NOTE: CONCRETE SHALL BE 0 O EDGE ZONE ATTACHMENT REQUIREMENTS SHALL BE USED. SCALE: 3,500 PSI @ 28 DAYS ' FOOTINGS SHALL BEAR ON CEILING SHEATHING UNDISTURBED SOIL WITHIN GENERAL NOTES: cz I� o GYPSUM WALLBOARD 5d COOLERS 7"EDGE/ 1 0"FIELD 15 TONS PER SQUARE FOOT FIRE RESISTANCE RATINGS - AN5I/UL DES 426 z WALL SHEATHING BearingRating , • g • The information on thisset of construction documents Is to relate basic design 6_' z m " Intent and framin details. The are Intended as a construction aid,anot as a d si n ,,, . . Wall n Finish Rating U > STRUCTURAL PANELS 8d 4' EDGE ZONE - 1 C"0/C- 6"AT PANEL EDGES AND 12 AT 3 HR. 2 I 0 Min L INTERMEDIATE SUPPORTS IN THE PANEL FIELD I . Nailheads - Exposed or covered with joint finisher. the IdIfor Thegeneralcontractor is responsible f h , Nz 1- substitute for generally accepted good build ng practice and are in compliance wit to Li i Bui ng Code New York State. ntraor 8d INTERIOR ZONE- I C"0/C - 6"AT PANEL EDGES AND 1 2"AT 2. Joints - Exposed or covered with fiber tape and joint finisher. As an alternate, I— E a� 0 INTERMEDIATE SUPPORTS IN THE PANEL FIELD nominal 3/32 in. thick gypsum veneer plaster maybe applied to the entire surface 2X4" WOODf h t t construction standard d d t ails a fpd to r professions y U _„�.,_,,..,:.. . ., _.. of Classified veneer baseboard. Joints reinforced• finished �s ructurally sound dweatherproof completed product. a FIBERBOARD PANELS PANELS 7/1 6" 6d 3"EDGE J 6"FIELD in. FIRESTOPPING NG C �, CVS c . .. ......... . .,... , ,.,,. ... ., , , „ .. ., /8 in. long, 0.091 5 in. shank dram, 1/4 ,.. _ ...... . / EST _ 25/32" 8d 3"EDGE/6°FIELD coated nails 2-3/8 in. . 113 in. shank dia , I �� • coordinate all subcontractors, scheduling of work and 3. Nails Gd cement coated nails 17 •,,,, ,, , ,,,,,,,, , • , ,_, diam heads and 8d cementlong, 0 m General contractor to GYPSUM WALLBOARD 5d COOLERS 7"EDGE/ I 0"FIELD 9/32 in. diam heads. C) interaction between trades. 8d 4' EDGE ZONE- 1G"O/C -'C''AT PANEL EDGES AND 1 2"AT 4. Gypsum Board - ' - 5/8 in. thick , three layers applied to existing side, �- •� HARDBOARD INTERMEDIATE SUPPORTS IN THE PANEL FIELD horizontally. Attached to studs with thelll/8 in. nails spaced'6" o.c.s Vertical ILINIFAIIII �— _ • The contractorresponsible for hat all work and construction meets ... .... . . ... ...._.... . ... ... .. .. . joints locatedoe studs. All joints facelayers staggered with joints in base � � �!� �� �'`..%'l�� 1-1C-C-'�-.�� i5 spo t 8d INTERIOR ZONE- 1 G"0/C- 6"AT PANEL EDGE=S AND 1 2°AT layers. Joints of each base layer offset withjoints of base layer onopposite side. �" r' or exceeds current federal, state and localcodes, ordinances and regulations, etc. fYP rikk III U INTERMEDIATE SUPPORTS Ii THE PANEL FIELD 5. Existing exterior metal siding to remain. ����--- , (� .-�` jam. O�'L tV _�- These codes are to be considered as part of the specifications for this building plan. z USG FIRE RESISTANCE ASSEMBLIES - UL Des U426 FLOOR SHEATHING O4 © g• If in the course of construction, a condition exists which dila reel with that as , " 2" IE indicated on these drawings, the contractor shall stopwork and notifythe engineer STRUCTURAL PANELS - !"OR LESS 8d 6 EDGE/ I FIELD 'Bearing the UL Classification Mark 9 g z INFORMATION TAKEN FROM ©2013 United States Gypsum Company 3 g" METAL STUDS immediately. Should he fail to follow this procedure and continue work, W • Nailing requirements are based on wail sheathing nailed C inches O.C. at the panel edge. If wall sheathing is ns led 3 inches O.C. at the panel edge to obtain FIRESTOPPED he shall assume all responsibility and liability arising therefrom. J higher shear capacities, nailing requirements for structural members shall be doubled, or alternate connectors,such as shear plates,shall be used to maintain thecso co— load path. • Dimensions takeprecedent over scale - DO NOT SCALE DRAWINGS. Q ien wall sheathcontinuous over is coi"nected members, the tabulated number of na:Is shall be permitted to be reduced to I-16d nail per foot. BASIC PLUMBING HVAC. " Corrosion resistant I 1 gage roofing Harts and 16 ciac�e Staples are permitted, check IBC for additional requirementF. U O o • N� FIRE BATED WALL ASSEMBLY DETAIL with the�CC//ANSI Af acI cessible ba 2003 standards.learances � specifications to comply GENERAL s m l Q U z »..._._...._._.. .._...~..•._............. , ... .. . ,_. .. ... .... ... NOT TO SCALE Z — z o • Reconfigure duct work as required; balance all heating and cooling to regulate even _ CLIMATIC AND GEOGRAPHIC ©=SIGN CRITERIA DEFLECTION LIMITS I _ � � �• temperatures throughout floor areas. Relocate thermostats if required. ° WEPTLIERING SEVERE i `FROST LINE. DEPTH 3'-0" CONSTRUCTION L S or W I�� BASIC ELECTRIC: W ..c / � / ` 4%11 RAFTER kV: T)=F;MITE MODI PLATE T(aI L-AVY goof mernb'r3. WOOD JOIST a 'II WOOD J015T `: 0 • Disconnect and remove all abandoned electrical devices equipment; replace all DECAY I.1GI1T YO MOI��i_,ti4TC sL.I,^ortin:a :•last..r . ling Ubu G L/�•C0 / RAFTERaBLOCKING � ( � � � ' remaining devices � covers with new to match existing. Provide all required 5u poor tin iorrplaster cep ing U2..4G U2-4J ��'� JOIST HANGER � ♦F�/INTER Dir51+.�N TEN'P. f I F � ' � I� fII � TOP PLATE a � EMERGENCY LIGATING and battery backed EXIT signs as required by code. LGE SHIELD UNDER,- AS r>=i�ivtAhUFAG i U7c._R5 nen QUI:r�rt:r•�C..�lin? Li!�0 U I b0 GIRDER/HEADER I a ' TOP PLATE LAYME\T REQUIRED SPf C Fic,ATION S/STATE CODE -icor members: LOGO - WOOD GIRDER �,� (I war WOOD JOIST 1 a 41.441111411111 • WALL STUD .. FLOOD HAZARDS Exteriai• walls 4 interior partitions: war (I WALL STUD \\� a „ . , _ „.. ,.. . , with brittle finishes L/240 iiia..,._.........-,._....._........,..,...»............... .... .»........,... .w....,_.,..,......._........................ ..................... ..»._»....... ......._..... with flexible finishes L/120 JOIST FRAMING OVER WOOD GIRDER JOIST FRAMING FLUSH WITH GIRDER/HEADER TYPICAL RAFTER TO WALL STUD CONNECTION ALTERNATIVE RAFTER TO WALL STUD CONNECTION ," DESIGN LOAD CALCULATIONS MINIMUMUNIFORn1LYDISTRiBUTEDLIVELOADS{p�f) Ili WIND RESISTANT CONSTRUCTION CONNECTORS �� U 0 FLOOR SYSTEMS 50 CONNECTION LOCATION: PART NUMBER: NOTES: z NKING STUDS �/ U N NASSEMBLY 1©© �% i. RIDGE-TO-RAFTERS CS20 @ 2 I" APPLY TO EACH PAIR OF RAFTERS ILI Q_ i 0 CATWALKS 40 WALL STUD Ni...' �A 3 _ CRIPPLE STUD 1/ METAL SOLD ZU-I > O I\ CO5 BO TO FLOOR \"� 11441%41a - DOWN STRAP RAFTER TO WALL H7 APPLY TO EACH RAFTER Z zDECKS a 38 16d SINKERHEADER I II APPLY TO EACH RAFTERU OmR©OMS I©© DOUBLE JOISTa `I ` t 115T, FLOOR WALL STUD a NAILS A5 PER /-3- 2"X4"WD STUDRAFTER TO PLATE H8 or H2.5 Z— J\ ' It t 4` MANUFACTURER @ CORNER TYP. LLJ O (�STAIRS EXITS I©© "` + JACK STUDS IIIA II ' h rioN 2"X4"SILL PLATE TO WALL STUD C520 @ 18" APPLY TO EACH WALL STUD Z O U N,� • ( a ' 15T, FLOCK PLATEILII 1 I ( �I SUBFLOORa, ` PLATE 2ND. FLOOR WALL-TO-I ST. FLOOR WALL LFTA or C520 @ 36" APPLY TO EACH WALL STUD O LC) mCRITERIA FQ L CALCULATION OF DEAD LOA© II ' ''' +� �i� RIM JOIST TYP. HEADER TO JACK STUD CS20 @ 12" APPLY TO EACH JACK STUD U - <9 ACTUAL WEIGHTSi OF MATERIALS REFERENCED TO A.I.A. RIM BOARD ' I OEDOUBLE JOIST FOR NON-BEARING WALLS III, 41` DBL. SILL PLATE CRIPPLE STUD TO HEADER H3 APPLY TO EACH CRIPPLE STUD LARCHITECTURAL GRAPHIC STANDARDS WTYPICAL HEADER CONNECTIOIJ DOUBLE SILL PLATE �� \'� !' "1 II ANCHOR BOLT 'i; 0�' (I)#4 REBAR IN SHEAR WALL HOLDDOWN ANCHOR SSTB 16 APPLY TO EACH SIDEWALL ENDFOUNDATION WALL ,�'. SHEAR CONE-MIN, SNOW a 1101,14:(0/- 12" LENGTH WRAP UNDER DOUBLE SILL PLATE GROUND SNOW LOAD 45 lbs. SILL GASKET PROVIDE 1/2"SPACINGS 11 1ST. FLOOR-UNDER-SILL PLATE LPT4 30"MIN. b FOUNDATION (USE WITH 3" SQUARE WASHERS) BETWEEN THE END STUD REBAR LENGTH '''`1I -c• WALL T'P. TERMITE SHIELD AND THE 2 OTHER STUDS P USE THE FOLLOWING OR APPROVED SIMPSON METAL CONNECTORS FOR PROPER WIND RESISTANT CONSTRUCTION. D IS I d ? I/2" MIN. ® 04, FOR ALLOWING FOLLOW MANUFACTURE'S RECOMENDED INSTALLATION INSTRUCTIONS TO ACHIEVE MAXIMUM UPLIFT LOAD CAPACITY, SEISMIC Iiirt416: � HOLDDOWJ INSTALLATION CONNECT CORNER STUD FROM CORNER oDBL. SILL PLATES ®', TO TRANSFER SHEAR IST, FLOOR TO FOUNDATION CONNECTIONS DESIGN CATEGORY B (TO OVERLAP JOINTS) �1r e FASTEN WITH (2) 16dQ" >J FOUNDATION WALL a /� COMMON NAILS @ 6"O.C. METAL HOLD-DOWN/UPLIFT ANCHOR , i WIND 124 I 1 I WIND SPEED 120 mph SIDEWALL /AINiiip.4 ENDWALL V-1•1 Cr}.14 OSURE CATEGORY B ��OF NEN, ��4 SILL PLATES TO FOUNDATION ANCHORING SHEAR WALL CORNER CONNECTION ,`P �ENJA",'1//�� ©♦ ® ENG 1 r— i..itt '7 M h U1 +►`etilb 6 PAGE: . CONSTRUCTION DETAILS $ WIND LOAD PATH CONNECTION DETAILS ' °ss';al\ . . NOT TO SCALE '9OfiESS(GNA 4 . 07 . 15 5 'UNAUTHORIZED ALTERATION OR ADDITION TO THIS DRAWING AND RELATED DOCUMENTS IS A VIOLATION OF SEC. 7209 OF THE N.Y.S. EDUCATION LAW'