Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
40164-Z
,,,D4s�iFol' eio Town of Southold 12/13/2015 f y cf.,. P.O.Box 1179 y' x t, 53095 Main Rd ®. 4* ,e,i ' Southold,New York 11971 KYKK CERTIFICATE OF OCCUPANCY No: 37953 Date: 12/13/2015 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 50 Fred St,New Suffolk SCTM#: 473889 Sec/Block/Lot: 117.-4-22 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 10/2/2015 pursuant to which Building Permit No. 40164 dated 10/9/2015 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: roof-mounted solar panels on existing one family dwelling as applied for. The certificate is issued to Wiederlight,Marc&Ellen of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 40164 11/18/2015 PLUMBERS CERTIFICATION DATED 7 i _ r Authorized Signature `'- TOWN OF SOUTHOLD SUFFau-�o� BUILDING DEPARTMENT TOWN CLERK'S OFFICE s>o o�4'i SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 40164 Date: 10/9/2015 Permission is hereby granted to: Wiederlight, F Marc 50 Fred St PO BOX 6 New Suffolk, NY 11956 To: Install roof-mounted solar panels on existing single-family dwelling as applied for. At premises located at: 50 Fred St, New Suffolk SCTM #473889 Sec/Block/Lot# 117.-4-22 Pursuant to application dated 10/2/2015 and approved by the Building Inspector. To expire on 4/9/2017. Fees: SOLAR PANELS $50.00 CO -ALTERATION TO DWELLING $50.00 ELECTRIC $100.00 Total: $200.00 Buil..•- spector Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HAIL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings,property lines,streets,and unusual natural or topographic features. 2. Final Approval from Health Dept.of water supply and sewerage-disposal(S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1%lead. 5. Commercial building,industrial building,multiple residences and similar buildings and installations,a certificate of Code Compliance-from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings(prior to April 9,1957)non-conforming uses,or buildings and"pre-existing"land uses: 1. Accurate survey of property showing all property lines,streets,building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant.If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00,Alterations to dwelling$50.00, Swimming pool$50.00,Accessory building$50.00,Additions to accessory building$50.00,Businesses$50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate ofOccupancy-5.25 4, Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy -Residential$15.00,Commercial $15.00 Date. c Oq 113 New Construction: Old or Pre-existing Building: X (check one) Location of Property: 50 Fred Street New Suffolk _ House No. Street Hamlet • Owner or Owners of Property; Ellen Wiederlight Suffolk County Tax Map No 1000,Section 117 Block 4 Lot 22 Subdivision Filed Map. Lot: Permit No. 1461 r(O9 Date of Permit. Applicant: GreenLogic LLC Health Dept.Approval: Underwriters Approval: . Planning Board Approval: Request for: Temporary Certificate Final Certificate: X (check one) Fee Submitted: $ 50.00 Ap �icant Signature �,,%®F SOUjyo Town Hall Annex : Telephone(631)765-1802 i 54375 Main Road * lig t Fax(631)765-9502 P.O.Box 1179 14, G Q ��� Southold,NY 11971-0959 �O I1 roger.richerttc'�t town.southold.ny.us o�y�OUNTY,��;•0 BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION Issued To: Wiederlight Address: 50 Fred Street City: New Suffolk St: New York Zip: 11956 Building Permit#: 40164 Section: 117 Block: 4 Lot: 22 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: Green Logic LLC License No: 43858-ME SITE DETAILS Office Use Only Residential X Indoor X Basement X Service Only Commerical Outdoor X 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures HID Fixtures Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Fluorescent Fixture Pumps Transformer Appliances Dryer Recpt Emergency Fixtures Time Clocks Disconnect Switches Twist Lock Exit Fixtures TVSS Other Equipment: 11.445kw Roof Mounted Photovoltaic System to Include, 35- Sun Power 327 Panel 2-SMA SB 3000 Inverters,and 1-SMA SB 5000 Inverter Notes: Inspector Signature: Date: November 18, 2015 S4-1.--72.:3, Electrical 81 Compliance Form xls rAof 404'0€ t\s, P19(1,d-S` 4® LVO TOWN OF SOUTHOLD BUILDING- DEPT. 141413 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLUMBING [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING / STRAPPING [ ] FINAL [ ].FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] CAULKING REMARKS: PV S'Crj5C - DATE O ( /< INSPECTOR �� Pacifico Engineering PC —' Engineering Consulting 700 Lakeland Ave, Suite 2B °' 45 Ph: 631-988-0000 Bohemia, NY 11716 6J` ICs c Fax 631-382-8236 www.pacificoengineering.com solar@pacificoengineering.com November 24, 2015 \--AL �Town of SoutholdDEc 1 4 2015 I� Building Department 54375 Route 25, P.O. Box 1179 Southold, NY 11971 f, Subject: Solar Energy Installation fo4 Ellen and Frederick Wiederlight Section: 117 50 Fred Street Block: 4 New Suffolk, NY 11956 Lot: 22 I have reviewed the solar energy system installation at the subject address on November 24, 2015. The units have been installed in accordance with the manufacturer's installation instructions and the approved construction drawing. I have determined that the installation meets the requirements of the 2010 NYS Building Code, and ASCE7-05. To my best belief and knowledge, the work in this document is accurate, conforms with the governing codes applicable at the time of submission, conforms with reasonable standards of practice, with the view to the safeguarding of life, health, property and public welfare. Regards, Ralph Pacifico, PE Professional Engineer () 14E }0 ,0, a PAC/E/ 'Q.r- / NQ CO 'k.'. A '4.11h S 066A , , N/ VO A.�Er& Ralp alEngineer NY 066 s- ,GE04744306 FIELD Il�'SPTDCXQN rtEP'QR'P AATg ' CO NTS , ' y • 1 ME l J I ' 11.1111111111111111110111111011111.1.111111111111111 V;lY of 1 >.Yiim C) O A ( T) , +•-- Elmo - d CA FOUNDATION(2NI5) MR • t'Ll 37 . a= - 2 . L., 5 , , a ROUGH FRIG& MOM • . �' . PLUMBING . . . . - , , . . pi ,j I AIM . • , • . I . • INSULATION PEA N,Y. ' ' H STATE ENEROY COMB . _ , ; iiii-iI . FNAL' MIN NM ,. � r�`'�''limis Bei i�.� \-j . `a1 1 , TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL - Board of Health SOUTHOLD,NY 119714 sets of Building Plans TEL: (631) 765-1802 Planning Board approval FAX: (631) 765-9502 / ( O Survey - SoutholdTown.NorthFork.net PERMIT NO. I(P I Check - - Septic Fo N.Y.S.D. C. - . ' Trustees Q I�j Flood Permit Examined ( 6 l ,201 Storm-Water Assessment Form 0-- rr,, Contact:Approved f V 1 ,20 Mail to: GreenLogie LLC , Disapproved a/c 425 County Road 39A,Southampton,NY 11968 i Phone: 631-771-5152 9®m � 1 a Al Expo 0 —: - DL ' ; I; L 1 ' 1n , l ' i l 11 Buil 1 ' OCT 2 2015I L), - - 'PLICATION FOR BUILDING PERMIT Date ' July 23 ,. ,,2015 1 re• `` ii INSTRUCTIONS a.This application MUST be completely filled,in by typewriter or in ink and submitted to the Building Inspector with 4 - ' sets of plans,accurate plot plan to scale. Fee according to schedule. .b.-Plot plan showing location of lot,and of buildings on premises,•relationship to adjoining premises or public streets or , areas,and waterways. , c.The work covered by this application may not be commenced before issuance of Building Permit. ' 'd.Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. - e.No building shall be occupied or used in whole or in'part for'any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. - ' f.Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date.If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize,in writing,the extension of the permit for an addition-six months.,Thereafter,a new permit shall be required. , - :" , , - ' ' APPLICATION IS HEREBY-MADE to the Building Department for the issuance of a:Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New,York,and other applicable Laws,Ordinances or Regulations,for the construction of buildings,additions,or alterations or for removal or demolition as herein described. The , applicant agrees to comply with all applicable laws,ordinances,building code,housing code,and regulations,and to admit , authorized inspectors on premises and in building for necessary inspections. ' , GreenLogic LLC ' (Signature of applicant or name,if a corporation) - 425 County Road 39A, Southampton, NY .11'968 (Mailing address of applicant) , State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician,plumber or builder ' Contractor Name of owner of premises Ellen'Wiederlight - (As on the tax roll or latest deed) - S ' If app 'cant is a corporation, signature of duly authorized officer .. , e and title of corporate officer) - - , Builders License No. 40227-H - S - Plumbers License No. N/A ' Electricians License No. '43858-ME S Other Trade's License No. ' N/A 1. Location of land'on which-proposed work will be done: ' 50 ' ' - Fred Street New Suffolk • . _ ' House Number Street - Hamlet ' - - , County Tax Map No. 1000 Section 117 Block 4 - ' Lot 22 ' -, Subdivision - S Filed.Map,.No. _o r n <�. Lot , iio` w..--14't<<,;C./P, ,:ri!t;c,1 temt,,:a fr a% '\;%Uta z b+e:.?'<_i cloieF:rirign - f , - 4 2. Stateexistinguse and occupancy of premises and intended use and occupancy of proposed construction: ' a. Existing use and occupancy Single family dwelling b. Intended use and occupancy Single family dwelling 3. Nature of work(check which applicable):New Building Addition Alteration Repair Removal Demolition Other WorkRoof mounted solar electric system (Description) 4. Estimated Cost _ , Fee (To be paid on filing this application) 5. If dwelling,number of dwelling units Number of dwelling units on each floor If garage, number of cars 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of existing structures, if any: Front , Rear Depth Height Number of Stories Dimensions of same structure with alterations or additions: Front Rear Depth Height - Number of Stories 8. Dimensions of entire new construction: Front Rear Depth ` Height Number of Stories - 9. Size of lot: Front Rear Depth - - - - 10. Date of Purchase Name of Former Owner 11. Zone or use district in which premises are situated - - - - 12. Does proposed construction violate any zoning law,ordinance or,regulation?YES • NO X 13. Will lot be re-graded?YES NO X Will excess fill be removed from premises?YES NO 50 Fred St 14.Names of Owner of remiesEllen Wiederlight Address New Suffolk, NY 11956 hone No. 631-765- 13 Name of Architect t l i co E f'Q 1 Address`100 tC teja f�v�,�c`�fl' }" one No (-Al-k-01)( MOO Name of Contractor GreenLogic LL' Address 425 County Road 39A- Phone No. •631-771-5152 Southampton,NY 11968 15 a. Is this property within 100`feet of a tidal wetland or a freshwater wetland? *YES NO * IF YES, SOUTHOLD TOWN TRUSTEES &D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES - NO *IF YES,,D.E.C. PERMITS MAY BE REQUIRED. 16.Provide survey,to scale,with accurate foundation plan and distances to property lines. . 17. If elevation at any point on property is at 10 feet or below,must provide topographical data on survey. 18.Are there any covenants and restrictions with respect to this property? *YES NO * IF YES,PROVIDE A COPY. - STATE OF NEW YORK) - SS: - - COUNTY OF Suffolk ) Nesim Albukrek being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)He is the • - Contractor (Contractor,Agent,Corporate Officer,etc.) _ _ of said owner or owners,and is duly authorized to perform or have performed the said work and to make,and file this application; that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be performed in the manner set forth in the application filed therewith. . Sworn to before me thi GI day of P1bar-20 !oroariuk (1/411( -Notary Public • - ignature of Applicant TAMARA L.ROMI;:RO ,- Notary Public,State of New WOW- No. ork-No.01R06217368 - Qualified in Suffolk County - - - Commission Expires 2/08/2018 - AO .r Scott A. Russell ,.,,M` ° "` � �`-l. _ STORMWATER SUPERVISOR } MANAGEMENT SOUTHOLD TOWN HALL-P.O.Box 1179 1: 15 41 / �] 53095 Main Road-SOUTHOLD,NEW YORK 11971 1 ,t" Town of Southol CHAPTER 236 - STORMWATER MANAGEMENT WORK SHEET ( TO BE COMPLETED BY THE APPLICANT ) I DOES THIS PROJECT INVOLVE ANY OF 'J E FOLLOWING: i {CHECK ALL THAT APPLYI ii Ii Yes No f ' ®D A. Clearing, grubbing, grading or stripping of land which affects more 1 than 5,000 square feet of ground surface. ;; 11 DO B. Excavation or filling involving more than 200 cubic yards of material '€ i, within any parcel or any contiguous area. 1! li ®D C, Site preparation on slopes which exceed 10 feet vertical rise to 1. 1. 100 feet of horizontal distance. F; ,1100 D. Site preparation within 100 feet of wetlands, beach, bluff or coastal ;! i' erosion hazard area. 1f 0E E. Site preparation within the one-hundred-year floodplain as depicted IF 111 on FIRM Map of any watercourse. `i i', DO F. Installation of new or resurfaced impervious surfaces of 1,000 square ' feet or more, unless prior approval of a Stormwater Management Control Plan was received by the Town and the proposal includes 1' in-kind replacement of impervious surfaces. _; If you answered NO to all of the questions above,STOP! Complete the Applicant section below with your Name, Signature, Contact Information,Date &County Tax Map Number! Chapter 236 does not apply to your project. If you answered YES to one or more of the above,please submit Two copies of a Stormwater Management Control Plan and a completed Check List Form to the Building Department with your Building Permit Application. li APPLICANT: (Property Owner,De,ignt Pi ofeastotxtk Agent,Contractor,Other} S. .T.tyf. h: ]d00 Date: District €1, NAMED GreenLogic LLC (Nesim Albukrek) ` 117 .4_ 22_ 7/23/15 i l �, E! Section Block Lot ( '-',, ' *'*"FOR BUILDING DEPARTMENT USE ONLY *' ,i Contact rnrormanotu 631-771-5152ii ; if ne4r'ea!:wctei` 0....14►V1 C ) 1 Reviewed eci By: _ {/ e ■,k i 1 14a1,� i Property Address/Location of Construction Work: ; € Date: i I11 nV �� ' Approved for processing Building Permit. i Stormwater Management Control Plan Not Required. 11 NtI,J3 )Cl NV 1 Ei Stormwater Management Control Plan is Required. 11 i(1 ® (Forward to Engineering Department for Review.) i;; ......................... .,, ,.....,,,,.,w„. ,...1 (t. ._.,.,..... .µ,if FORri * sic -Pros 2014 8011 e Town Hall Annex ' * • *' Telephone(631)7654802 54375 Main Road CA {631)765gg5Q P.O.Box 1179 ; ri _ Q , roger.richertdeciwn.SOUtilO .nV.US Southold,NY 11971-0959 YO,1ti BUILDING DEPARTMENT TOWN OF SOUTHOLD APPLICATION FOR ELECTRICAL INSPECTION •REQUESTED BY: Barbara Casciotta Date: 1@q115 Company Name: GreenLogic LLC Name: Robert Skypala • License No.: 43858-ME Address: 425 County Road 39A,Southampton, NY 11968 Phone No.: 631-771-5152 JOBSITE INFORMATION: (*Indicates required information) *Name: Ellen Wiederlight • *Address: 50 Fred St, New Suffolk, NY 11956 *Cross Street: Fanning Road j *Phone No.: 631-765-1139 Permit No.: Tax•Map District: 1000 Section: 117 Block: 4 Lot: 22 *BRIEF DESCRIPTION OF WORK(Please Print Clearly) zrA‘ Mi io r dec H G 5 * ' - � tf )Pr ���-� - Rat o .ki l SMA AS2)( .* (Please Circle All That Apply) *Is job ready for inspection: YES NO Rough In CO *Do you need a Temp Certificate: a NO Temp Information(If needed) " *Service Size: 1 Phase 3Phase 100 150 200 300 350 400 Other *New Service: Re-connect Underground Number of Meters Change of Service Overhead Additional Information: PAYMENT DUE WITH APPLICATION a . � pd 82=Request for Inspection Form �� �� Cp.GR EEN LOGIC® ENERGY September 29, 2015 Town of Southold Building Department Town Hall 53095 Route 25 Southold, NY 11971 Dear Building Inspector: Pleasefind attached a building permit application on behalf of Ellen Wiederlight who has engaged us to install a roof-mounted solar photovoltaic (PV) electric system at her home at 50 Fred St, New Suffolk, NY 11956. In connection with this application, please find attached: • Building Permit application • A Storm Water Assessment Run-off Form • Certificate of Occupancy Application • Application for Electrical Inspection • 2 Surveys of the Premises • 4'Engineer's Reports (2 originals and 2 copies) • 2 One Line Electrical Schematics • 2 Spec. sheets of the solar panels (SunPower 327) • 2 Spec. sheets of the inverter (SMA SB5000/SB3000) • 2 Code Compliant Manuals for Racking System • GreenLogic Suffolk County Home Improvement License • GreenLogic Certificate of Liability Insurance • GreenLogic Certificate of Worker's Compensation Insurance Coverage • Installation Manager's Master Electrician's License • Check for$200 ($50 Building Permit/$50 CO/$100 Electrical) Please let us know if you need anything else in connection with this application. Yours truly, , 64kt/wk.__ Barbara Casciotta Office Manager GreenLogic LLC 631-771-5152 ext. 117 GREENLOGIC LLC c www.GreenLogic.com Tel: 877.771 4330 Fax: 877.771.4320 SOUTHAMPTON ROSLYN HEIGHTS 425 County Rd 39A 200 S Service Rd.,#108 Southampton, NY 11968 Rosyln Heights, NY 11577 ( GREENLOGIC® ENERGY 1, DEC 1 4 2015 ,L), December 7, 2015 nl' . , I ih,",. - tt The Town of Southold Building Department 54375 Route 25 P.O. Box 1179 Southold, NY 11971 Re: Building Permit No. 40164 Ellen Wiederlight 50 Fred Street, New Suffolk To the Building Inspector: Enclosed please find the Engineer's Certification Letter and the Town of Southold Certificate of Electrical Compliance for the above referenced solar electric system. Please close the building permit and send the Certificate of Occupancy to the homeowner. Please let me know if you have any questions about the installation. Sincerely, faatitiu„..41,etet Barbara Casciotta Office Manager Barbara@Greenlogic.com 631-771-5152 Ext. 117 GREENLOGIC LLC o www.GreenLogic.com Tel: 877 771 4330 Fax 877 771.4320 SOUTHAMPTON ROSLYN HEIGHTS 425 County Rd 39A 200 S Service Rd.,#108 Southampton, NY 11968 Rosyln Heights, NY 11577 w.:. i- „st ?F a S rrE If r 7 S 1J Y 3 f ;16 'I' 3S,' 71" it+3 !•' r I r .9 !, c nr« •ra rr s^- r• ,r. !1k!!i, 3)PA M1 @, #,l` ) I y I ,S! t; ;1' rs�.. ! a p. S •F ;{', - P� '7^ ;Eli, I If it'r ! h 1 ,f 1 iF s,r•^ # ili.Il1#,f !.# d I PI Y' I S aC' Ft :P _ n)...,. .#._.t'. 11 E'ni li�.: •I t ,lE,f! r,.' ,h' .C;atm,, i,i, ,+, i._ • EE- - )` e) ,s+I 'i' e!I 'i# S iii ,:rS'xS S^• ,. I"+, , •l`' tP,• {. ., s :I 'dF ai oll.x+1: ..3_: .t i„ •'h1 :s1" ''I�E , , , `�-;, r s ,t. Ih r Ir'„ !,:,,I'.)ta'6'm SSil,e,,! ..i @'1r6" :P g:-c9,",,,,,,on'-, x.l. ,Illus r''i•s :.,� ,"-3,9.0{Ilii t�i' �€• , '. If CO f i 41 I 1-i'''ii/11''t.7i11 (.I..1' l • t I:�eI Ifr @ , -, )a,l_�. . tI:`I I,_i'�L ���1 I.# ,V iJe S r I � 1,,, i M ,n t uw.....w tnelM1w.,.wuu...ww.w.wuw.w:. uu. (' I'1 c el a w..ww................w:w I X1..,1 f t' IJ @r7 li J�'• 1', I�!{i' Il..li}7:,l;l:rl'.Id:.'11�:�.f` i1, i1 ' 1 .] i- f t at , 1 ll:: • :, 11 is ,•11.@;r°r�.'lP,I ': h,�. I;r i:iF'r°r.;I/.I( 1 III -1.OW L ()I:. ::I't..I i,..I'I'I-f C) ► .?�s;•,...�,. I I)I ,�; 1..L' '' f-,N ::,1.117170 l..# (:;t J ISI`T"'I'', Pll I_W '1t't:,)'R�' i r I ,.# 'e.., S _€1' `,:. :;, 1',t#i 4 Pd as. Ilrl at)4(:).... I to 61(:1 - I '1;7 .... 1i1',,;, ;> �.;I ;;i fi,fal'L_It.::!•11'll'I'. h+lrafR';2 e4i f l._E..F:f 'lVlE'I::II:Is'-It HII J'' I'r.=� ' ), .. I �iiPx V' ',S % ,h,.t:l P II'i�_I�IN,...:, ll:}I..,.I ;� i I-41 s'1 n;I ! i i 111111.,) 1�L.d , ' 111111P 1 T!I �; ,y»,sal Y / ,L.'y�1 l5 r'`al l„#IrVViri I(,.rl �,. ll'Ip,,Cl,1r, •1 I'� VIII �i lJ.tP#I.Il,' ,[i'a�1 'Y) r,,'SP'-•^,:1'I�)�i V y V' + q1 4,I; L•- ,1-' g:: d.-i'.1 / IE j I...,)•I••i!,: ,.R!` I ty:�1:,. F Or I�III AR c.lt), :. 1 R� I ;,l ..z..;.17„ 11'I 1 ,;� ?uj ; ''^i;r I f " +:.:ilf:r t;�#F=71^' '1l II!V :'�;:�@+;'1P' f' 4114 [ )';d'::i f lihl{:i l_1(:?� :'^?E1.II,U,LE�'�kt:all:. - 1 1..`,',I:I;: ``° �+ 1[:r'.@g:a t>1,.. �I I: I,,rt;I [�..,, fiilir [] lu,. I ,�.,, r":;11,1 (..� i �' lhUlll' PRt,.la[:1f,::E.D LC. t t.D E,JR:,llyt:;ilE:: -•- 1 6, ,as; , 1 I,1- . h ;I- @ ,i..: Pf'Ik:.. ( II' IIIn1. II i 1.'.:2:; 4 ,1,..L;. I'W r ;'.4.,,I. -. 1 F, ,y ► ",.;,,,f.,,,;,,,, ,,•,',,', Eri,P I jC''tu ¢ -=}-:�t`...._-«.@_._................L�_I� 'I T•, 'V: - IrI - +ii '141 ,,,d.y- ' ,, Islai _ ,tr-°,% -_..11„C' ` 1.1., 1.1.1 1 i l 111 t I�wlh,ll' ;�I', fY:I`. Y.i�n II ';;;'::11-..--- 7;L:1;:A,y1E •ar( ;,„#:!+" :t,,s', .it __..._.......,. _,........._.....,...._-._,__._...............«.. .a• , r ''' r'+6 1 I'r 1llt>t tnt;, '` °' '' ) IEE .i Ir - � ;or � I' I; +���',!„"` „:„.is.„ {'u'+''e1•ul,: .I i)' ,;)+1 __ _ ;Y; "' >' �' I:`;r'OP:I,A il(?' 'Pi.K2{•d ...-rt:it.! '.aER\I 7' 1 ,4 Kik If 69•M.:I ,Ill r:IC.. r_,,rtp 1, a:' ...'�•,: / @'„ 1 Fi: f, _ IY ,.I` :, `�'f31 Y'1.:. 111 .i,, -- # • P f,.l II Ir-rs .t 1.0 IR:, :,73=1�- 'Y LI l4 I, f :I.L '� +. I t; ! f7 .1 `. MI. 'i.»,:Ji:r' :.4,:'tr7,{'v:1,a i..Yn.l,; ' Dir #',l,ts p� J -:3.. C1r'_•-_ ,.. @... . F 1 A !_A a' 3.P•.,1fv °I :aa T .i .. ''+3 ud'1 I' _ 'A-•,:,CI 'I"t'°° 1- +a "i1'11'Ill 1.1 u t ' `?'•:r;1•._ra«,. x'11 p•:el ,ir' III r!i' _ :'),!• .Jt 6'', N 7'., t I o 'l.i 'Ari, 'I:•i:V� uG�r;r'#: &• ., if) f:i' I .e.;.) wb/ l@.I Ltl,' I; 7w+vu...•."•'ell.11"' #w'F... 1 C-•' of i ,..a :IJ,, r . }1..'Ih _ ,i1j., Illill,l, �!1 ..1' :,1r ,,, " _ L...�.._._.._._.... , p .., .� .4o..a. t:l!.1 r:+ 1 ' FIS. • _ ...._ _..- .• r.. _ - - 'i,..) 'I�Ils.enI j'I:ii Y" E.•IC:GM r' '' 15 If'i , :ol..�.nnlw - 1 i..5 i'1.1 .C+,Y,:�%'d t,:^i I �.I•al' •' 1....1 1.., h Jj .I p : 'I. ry V f+u{<; '•r III t S „ a,f':,,. .1. ,`4; I ,l,1,1' .1 ,. ' I'il I'@ °i" 69° _ I'`'3 d•f�l,e• -lY ,f...-..... i' Ilsifl7:{li'P..Itis'I ; Y>q1.7 - f I ;^'t Cr')(it'i. I ,I I 1 'ai,I' > s 7 �,," ,iY1,11!':_.-4{.,'l s'1 lac f'," ),,',!1•'46.'.#'.1 'I,:... 'I rs ,,„a,, ,M• .441.'if ii,','^ '.,:., ` 11 �'J �f°11 Vig .! i.r I I:I.) 1 : I ^;' h.n .fl_'J; '1 .. ,I !�li I %;6','6i,' !!1a +: 1wWl 1 r - 5F,11•t i +, 'I�(,J #I 11,0,„i*)( I.•' 41.-.. .� •1 I 4 ` �' N,u''.w:a..u.. '• 1 Y II....._.!•f 1� 4, 5- 1 1.., .J ', Vnll,l t.0,ul :1;y'9' I Y !r i' i',,'''. r 11�'Ells:'. ',�.°��•uptIr'.i.{it'.�� :.1,. f i,L, r� Y �I C.1, Jr 3 lrr3.l;.,w....i,, #�i , ..ee1411 L!.? � ; Y 4r '; .:"7:-.., l; i -4„„:,-.;,,, \ 'r.-:./ ,.','' \ 5V<V„V \/4,V"' i \ \ 5 r\ .rir ' .. -'1 r" ,.— ,..�.. ` �, 7\ ,�+.',".,:'� ,'m ../.>'-''''''''A yw /,„.4 rr 4-:'',,...' N : r � .>i+tt•� i ny'.0 t r'N Y: :=t „ -;”•...r'� .•.� �'� �,F: l''' r`4l. ',� ,lCX ✓ .µ ',".el-,'-t- ✓ i %-",'-',:;,..4,/, ✓ .s•. ,C�y ."",, � ''y..r �4"''i. ,.f, � e <;.,, � \ ti(�a S' 1. �;y. -�.� .;.'" .1,-,;% -k. N-t. 'it.,---4,,, t�.-z .f 1 ,4,-,,, r.0 n'.., w�l• �: F � i, � �� -?',-••-;s.`, �rs. �,{,. t r � c ,,,x.". +�. � _,,_�,� r� {^��v� u;�r��.y lC.{{�jy' ir 4<:.f ;;--/-)—A,.',,,4 -2._,3 '�i s�" � _�i r� S . 'Y S ..mss, } :i� � � f 4,. .•. v. :.K':Y� �T':'1;ivt ,i,.1'.f +,.+ �� .0 #-:,.:i.',n Y f` p� ,..11---if, r y..- *.t, f "`F. yam, .4,,T;;::::::, �YF i 3: (t...FF ; _ ,( y Suffolk CountyExecutive's Office ofConsumer AffairsOvii � � ': VETERANS MEMORIAL HIGHWAY * HAUPPAUGE,NEW YORK 11788 r ) f ) '?- DATE ISSUED: 5/25/2006 No. 40227-H SUFFOLK COUNTY ": � g:ta s i„,-,,, Home Improvement Contractor License _ 4 ,, This is to certify that ,�.4-,. MARC A CLEJAN ,,,. ,„_, { , doing business as ...„.., ...,,„,„:„, f # GREEN LOGIC LLC ....I::141:1:-)` S ' having furnished the requirements set forth in accordance with and subject to the provisions of applicable laws,rules 2_t( r and regulations of the County of Suffolk, State of New York is hereby licensed to conduct business as a HOME (114-4 IMPROVEMENT CONTRACTOR,in the County of Suffolk. ` z ) Icy; Additional Businesses fi � M s s 5 �� , , . . NOT VALID WITHOUT .,,,&:..y, �, r.f s T , DEPARTMENTAL SEAL 11 ' AND A CURRENT ''.C .'-'<)/1 ,`x ” CONSUMER AFFAIRS �',.,./41r., f .- ID CARD g Y \7 3ti ,,r. lr ,. \fir Director &'Y �_ �:..... tiL.....'.r., ri'�i :, „•v^,� ., .* C�h:Tw. ,. , t”:",-4-'.'-'-`4t,-:41;"t^r' 4.1 ,j..}S✓h ..:� � J _.1.-,:,.4r; �Y) ?F f •fr� )-.:,{r t1�':^� Y�.k -I-4,Y'''. �,'' r,i w�V; I.' �s,5V ,� � tr x '/--_-, t , :;'y4^ fr r ' s ., �,� .. wv;�' �, '• ? . 5 � 'ri .�` r.',1;:: hr . " 1� .r, c :�r . sJs ^ / } �.`7 .{y,�. ... �s . * k },h. AY.:trY -F : j ,4;,,/. ^ , H� ,ys e ts CERTIFICATE OF LIABILITY INSURANCE DATE(MM/DD/YYTY) 01/30/2015 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER Brookhaven Agency,Inc. Brookhaven Agency,Inc. PHONE rG),,):(631)941-4113 FAX No):(631)941-4405 128 Old Town Road Suite C nI RESS: brookhaven.agency©verizon.net PO Box 850 CUSTOMFRPRODUID a: East Setauket NY 11733 INSURER(S)AFFORDING COVERAGE NAIC S INSURED INSURER A: HDI-Gerling America Insurance Co. Greenlogic,LLC INSURER B: Merchants Preferred Insurance Co. 425 County Road 39A,Suite 202 INSURER c: First Rehab Life Insurance Co. Southampton,NY 11968 INSURER D: INSURER E: AGCS Marine Insurance Company INSURER F: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE ADDLSUBR POLICY EFF POLICY EXP LIMITS LTR .INSR WVD POLICY NUMBER IMM/DD/YYYYI IMM/DD/YYYYI GENERAL LIABILITY EACH OCCURRENCE $1,000,000 A X COMMERCIAL GENERAL LIABILITY x x EGGCC000076915 01/31/15 01/31/16 AMSTOFRa EoNrrTErDaoa) $100,000 CLAIMS-MADE X OCCUR MED EXP(Any one person) $5,000 X XCU PERSONAL&ADV INJURY $1,000,000 X Contractual Liab GENERAL AGGREGATE $2,000,000 GEN'L AGGREGATE LIMIT APPLIES PER PRODUCTS-COMP/OP AGG $2,000,000 IR 7 POLICY I PF n LOC $ AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT B X ANY AUTO CAPI043565 8111/14 8/11/15 (Ea accident) $1,000,000 BODILY INJURY(Per person) $ ALL OWNED AUTOS BODILY INJURY(Per accident) $ SCHEDULED AUTOS X HIRED AUTOS PROPERTY DAMAGE Per accident X NON-OWNED AUTOS $ UMBRELLA LIAB _ OCCUR EACH OCCURRENCE $ EXCESS LIAB CLAIMS-MADE AGGREGATE $ DEDUCTIBLE _ $ RETENTION $ $ WORKERS COMPENSATION WC STATU- OTH- AND EMPLOYERS'LIABILITY Y/N Tr1RV I IMITR FR ANY PROPRIETOR/PARTNER/EXECUTIVE E L EACH ACCIDENT $ OFFICER/MEMBER EXCLUDED'? N/A (Mandatory in NH) E L DISEASE-EA EMPLOYEE $ If yes,descnbe under DESCRIPTION OF OPERATIONS below E L DISEASE-POLICY LIMIT $ C NYS Disability D251202 4/11/13 4/11/15 Statutory Limits E Installation Floater/Property MX183958282 4/15/14 4/15/15 $400,000 $1,000 Ded DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES (Attach ACORD 101,Additional Remarks Schedule,N more space Is required) CERTIFICATE HOLDER CANCELLATION TOWN OF SOUTHOLD SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN BUILDING DEPARTMENT ACCORDANCE WITH THE POLICY PROVISIONS. 53095 ROUTE 25 SOUTHOLD,NY 11971 AUTHORIZED REPRESENTATIVE <NSZ> ©1988-2009 ACORD CORPORATION. All rights reserved. ACORD 25(2009/09) The ACORD name and logo are registered marks of ACORD STATE OF NEW YORK WORKERS'COMPENSATION BOARD CERTIFICATE OF NYS WORKERS' COMPENSATION INSURANCE COVERAGE Ia.Legal Name&Address of Insured(Use street address only) lb.Business Telephone Number of Insured Greenlogic LLC 631-771-5152 425 County Rd 3M Ste 202 lc.NYS Unemployment Insurance Employer Southampton NY 11968 Registration Number of Insured ld.Federal Employer Identification Number of Insured Work Location of Insured(Only required if coverage Ls or Social Security Number specifically limited to certain locations in New York State,Le.,a 203801194 Wrap-Up Policy) 2.Name and Address of the Entity Requesting Proof of 3a. Name of Insurance Carrier Coverage(Entity Being Listed as the Certificate Holder) National Liability&Fire Insurance Company Town of Southold 3b.Policy Number of entity listed in box"la" 53096 Rte 25 V9WC653322 Southold NY 11971 3c. Policy effective period 06/15/15 to 06/15/2016 3d. The Proprietor,Partners or Executive Officers are included. (Only check box if all partners/officers included) X all excluded or certain partners/officers excluded. This certifies that the insurance carrier indicated above in box"3" insures the business referenced above in box "la" for workers' compensation under the New York State Workers'Compensation Law.(To use this form,New York(NY)must be listed under Item 3A on the INFORMATION PAGE of the workers'compensation insurance policy). The Insurance Carrier or its licensed agent will send this Certificate of Insurance to the entity listed above as the certificate holder in box"2". The Insurance Carrier will also note the above certificate holder within 10 days IF a polity is canceled due to nonpayment ofpremiums or within 30 days IF there are reasons other than nonpayment of premiums that cancel the policy or eliminate the insured from the coverage indicated on this Certificate. (These notices may be sent by regular mail) Otherwise,this Certificate is validfor one year after this form is approved by the insurance carrier or its licensed agent,or until the policy expiration date listed in box"3c",whichever is earlier. Please Note: Upon the cancellation of the workers' compensation policy indicated on this form, if the business continues to be named on a permit,license or contract issued by a certificate holder,the business must provide that certificate holder with a new Certificate of Workers'Compensation Coverage or other authorized proof that the business is complying with the mandatory coverage requirements of the New York State Workers'Compensation Law. Under penalty of perjury,l certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has the coverage as depicted on this form. ' Approved by:NICHOLAS ZULKOFSKE (Print name of authorized representative or licensed agent of insurance carrier) Approved by: 06/12/2015 ature) (Date) Title: Authorized Agent Telephone Number of authorized representative or licensed agent of insurance carrier: 631-941-4113 Please Note:Only insurance carriers and their licensed agents are authorized to issue Form C-105.2. Insurance brokers are NOT authorized to issue it. C-105.2(9-07) www.wcb.state.ny.us Workers' Compensation Law F 1 , \�F `.�r ,i l\ ff x i T "1 ^`� h 4�f` 1: 3 c f 111' • \ � ' � Suffolk County Executive's Office of Consumer Aairs �,- s �'�_ VETERANS MEMORIAL HIGHWAY * HAUPPAUGE, NEW YORK 11788 . ;�. -T -{ 1 DATE ISSUED: 12/10/2007 No. 43858-ME C ( �, SUFFOLK COUNTY v ;.2.;::::_ : 1 ,t_ Master Electrician License f ° This is to certify that ROBERT J SKYPALA r doing business as GREENLOGIC LLC // �'' having given satisfactory evidence of competency,is hereby licensed as MASTER ELECTRICIAN in accordance i ! with and subject to the provisions of applicable laws,rules and regulations of v y ; the County of Suffolk, State of New York. , y, ! Additional Businesses ; c\ (' . � . , . NOT VALID WITHOUT '7,<1. \ 77::4- DEPARTMENTAL SEAL AND A CURRENT . CONSUMER AFFAIRS tVt.' ' H)CARD Com- ,- _ A/7,7, Director ;S;„ ' c — ; ,-.5. ,•-, '-.-,‘Lr_ /;,\�. ,��,iPZ ,�, ,t�•. '''f-,i'�1^; .�( \\ ���1���.�/, t�- ,'��4` f�, '.;� 1� ! \� ,;�y���� ��4i��P<, ` �1,. ELECTRICAL INSPECTION REQUIRED AP },OSE®AS NOTED RETAIN STORM WATER RUNOFF DATE:_ : B.P.#. _-a_Ama .URSUANT TO CHAPTER 236 FEE: gr i re By: .. /ID OF THE TOWN CODE. NOTIFY BUILDING DEPARTMENT AT 765-1802 8 AM TO 4 PM FOR THE FOLLOWING INSPECTIONS: 1. FOUNDATION - TWO REQUIRED FOR POURED CONCRETE 2: ROUGH - FRAMING & PLUMBING 3. INSULATION 4. FINAL - CONSTRUCTION MUST BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS. COMPLY WITH ALL CODES--OF NEW YORK STATE & TOWN CODES AS REQUIRED AND CONDITIONS OF •-S@k 6tBiOWN-ZBA- 891ff+IO D-TOWN TRUSTEES PARE- OCCUPANCY OR USE IS UNLAWFUL WITHOUT CERTIFICATE OF OCCUPANCY 0 G S U N PW E R E20/327 SOLAR PA\EL • • 20% EFFICIENCY � 1 � ' SunPower E20 panels are the highest T— ` i efficiency panels on the market today, . * " {" r SERIES providing more power in the same - E amount of spaces f I. MAXIMUM SYSTEM OUTPUT . R � t� �� Comprehensive inverter compatibility ` .. -_ ' . r i ensures that customers can pair the highest- b t , 1 1 efficiency panels witn the rughest-efficiency , ' 1 j inverters, maximizing system output 1 REDUCED INSTALLATION.COST ..-._ + 1 More power per panel means fewer panels i per install. This saves bon time and money. RELIABLE AND ROBUST DESIGN -, ' SunPower's unique Maxeon'cell , S, ` THE WORLD'S STANDARD FOR SOLAR'' tecnnolagy and advanced module- SunPower TA1 E20 Solar Panels provide today's highest efficiency and design ensure industry-leading reliability, performance. Powered by SunPower Maxeon'''"cell technology, the E20 series provides panel conversion efficiencies of up to 20.1% The E20's - low voltage temperature coefficient, anti-reflective glass and exceptional ' - low-light performance attributes provide outstanding energy delivery per . peak power watt. SUNPOWER'S HIGH EFFICIENCY ADVANTAGE 20% �._. -_ _. — - 0/ • a2 °la 1?9 ' �. " , - ' R „-.^ ` 5% � w .. THIN FILMFILMCONVENTIONAL E�� 9_ 0`� MAXE0Nrm CELL SERIES SERIES SERIES TECHNOLOGYL ' sunpowereorp.com Patenred a:i-hack �mtact solar cell, - crov,ding he indust-y's n.t3',,:s• eP c enc, and•e iabil.ty C .f. US ` "i 4 0 a S' U N P E :R E2'0�/32.7 SOLAR PA\EL i MODEL: SPR-327NE-WHT-D ELECTRICAL DATA I-V CURVE Measured at Sto°durd Test Conditions(STC),lirodmnoe of 1000'/m',AM 1.5,and cell•empmoh'e 25'G, 7 Peak Power(+5/-3%) Pmax 327 W _.__ — _ __. _. _._. 6 1000 W/m2 - Cell Efficiency n 22 5% 5 ----)1\1 Panel Efficiency n 20 1 % Q 4 -800W/m2 > c Rated Voltage Vmpp 54 7 V lv 3 ... rCk'in;' Rated Current Impp 5.98 A v 2 O Open Circuit Voltage Voc 64 9 V 1 t `+. 200W/m2 `\ 3. Short Circuit Current 'Sc 6 46 A 0 - Maximum System Voltage UL 600 V 0 10 20 30 40 50 60 70 -- Voltage(V) Tem erature Coefficients Power(P) -0 38 i/K p Current/voltage characteristics with dependence on irradiance and module temperature Voltage(Voc) -176 6mV/K -- - - — Current(Isc) 3 5mA/K , TESTED OPERATING CONDITIONS NOCT 45'C+/-2°C -- -- -- - - _ Temperature -40°F to+185°F(-40°C to+85°C) Series Fuse Rating20 A - --- - ._ ------- - . - - 113 psf 550 kg/m2(5400 Pa),front(e.g.snow) Grounding Positive grounding not required i Max load w/specified mounting configurations ! ! 50 psf 245 kg/m2(2400 Pa)front and back ' MECHANICAL_DATA (e.g wind) Solar Cells 96 SunPower Maxeon"4 cells -..- -- __-_. - '- -- - - - _ High-transmission tempered glass with € Impact Resistance Hail: (25 mm)at 51 mph(23 m/s) Front Glass anti-reflective(AR)coating _ - Junction Box IP-65 rated with 3 bypass diodes Dimensions-32 x 155 x 128 mm i WARRANTIES AND CERTIFICATIONS Output Cables 1000 mm cables/Multi-Contact(MC4)connectors Warranties 25-year limited power warranty Frame Anodized aluminum alloy type 6063 (black) 10-year limited product warranty Weight 41.0 lbs(18 6 kg) I Certifications Tested to UL 1703 Class C Fire Rating DIMENSIONS; . MM (A)-MOUNTING HOLES (B)-GROUNDING HOLES >-• -25 5.'/ 22.2 <- .3'.'%C• -•- -^-- I (IN) 12X066[26] 10X042[17] :0I r P•322 269''-m 4,4 3243'5'4' -^ ' 0 0 • 0 • 0 0 0 • 0 + 1 �-'-'- (B) O 0 ♦ 0 0 . 0 . 0 . 1 -f I O 0 ♦ O 0 O O 9 ♦ aj " J0 0 0 ♦ 0 0 0 ♦ 0 a BOcH 2 .',< I O 0 ♦ • ♦ 0 0 0 ♦ • ♦ a P ENDS r, `r_' O 0 ♦ 0 ♦ 0 0 0 0 ♦ 4 3_L, • 0 ♦ 0 ♦ 0 0 0 ♦ 0 + I / �..,, ^--\ -^ .,., 'sri .. �. - t -a 1 E1 ..! (A)—�`"'�// I -- ?1:.,-24 02, tl- — ,. r i._t '21 1/ `ii- 60-I>. --- - r, Please read safety and installation instructions before using this product, visit sunpowercorp.com for more details. 012011 SunPower Corporation SUNPOWER,the SunPower Logo,and THE WORLD'S STANDARD FOR SOLAR,and MAXEON are trademarks or registered trademarks sun powe rca rp.co m of SunPower Corporation in the US and other countries as well All Rights Reserved Specifications included in this datasheet are suliect to change without notice Doca.ment#001-65484 Rev'B/LTR_EN CS 11_316 ,- ----- ---- — — NEW EQUIPMENT ----------------------- EXISTING SERVICE 120/240, 1PH, 3W PV-SA-1A <A) g' 110 �® 1 = INV-1 AC—COMBINER PANEL a ® ® �' I- -1 AC—CMB-1 r ___ -- (LOCATED NEAR-INVERTERS) ^-� I ,-p) sr (PV LOADS ONLY) I---1 AC DISCONNECT r e L _ _ ''� _ —___l i? `l AC-DSC-1 !I N ••.�a 2 -� 1 INTEGRAL DC/AC • DISCONNECT SWITCH -�- PV-SA-1B ',1 \: • a ® b t.j PV-SA-2A � r�11 BKR-1 LN �...�2rtINV-2 • { LØLJ e '} .)200A '.4! — ^- MAIN � $ BKR-2 FUSED° I NI al 0 T1' -....a-TL ... 2 1INTEGRAL DC/AC I BKR-3 imi �® A. DISCONNECT SWITCHr PV-SA-26 -}— PV-SA-3A -6Ai - 14.111 ® ... V V N .-2 -� 1 INV-3 (n3\ o-- t ,---- —L4----...L. r _- o !i'D. = j _ EGC } I --- 1r I III 1 ° i N —.•• 2 -.- 1 L—�� INTEGRAL DC/AC I III 1 ° G EC EXISTING I �g ,/d� DISCONNECT SWITCH ( ------I -1 —I GEC PV-SA--3B L.__ - J #6 Cu WIRING GUTTER EXISTING AC PANEL L ---_-----_---- IRREVERSIBLE SPLICE --- PROPOSED 3-LINE ELECTRICAL DIAGRAM Ellen & Fred Wiederlight REVISIONS - 50 Fred Street r., ,‘:.‘>1,,-:1,', Ay 7_LOGIC c-" ", � F.:N E�`�" `, New Suffolk, NY 11956 ELIMINATING THE COST OF ENERGY 1.) INITIAL SUBMITTAL WITH APPLICATION Page 1 of 2 Drawing No: WIEDRLT-3LD1 Revision: 1 Revised: 6/09/2015 EQUIPMENT&COMPONENT SCHEDULE CONDUCTOR SCHEDULE TAG DESCRIPTION SPECIFICATION TAG TYPE CONDUIT AWG./EGC a PV-SA-1A PHOTOVOLTAIC SUB-ARRAY SUNPOWER SPR-E20-327, 1-STRING OF 4-MODULES A USE-2/PV 1" PVC-40 10/6 PV-SA-1B PHOTOVOLTAIC SUB-ARRAY SUNPOWER SPR-E20-327, 1-STRING OF 5-MODULES PV-SA-2A PHOTOVOLTAIC SUB-ARRAY SUNPOWER SPR-E20-327, 1-STRING OF 5-MODULES B THWN-2 1" PVC-40 10/6 PV-SA-2B PHOTOVOLTAIC SUB-ARRAY SUNPOWER SPR-E20-327, 1-STRING OF 5-MODULES C THWN-2 1-1/2" PVC-40 4 - /6 PV-SA-3A PHOTOVOLTAIC SUB-ARRAY SUNPOWER SPR-E20-327, 1-STRING OF 8-MODULES " PV-SA-3B PHOTOVOLTAIC SUB-ARRAY SUNPOWER SPR-E20-327, 1-STRING OF 8-MODULES D THWN-2 1-1/2" EMT 4 -/6 INV-1 INVERTER, DC/AC SMA INVERTER, MODEL SB3000TL-US-22, 240V 1.)CONDUCTOR TYPES AND SIZES TO BE AD- INV-2 INVERTER, DC/AC SMA INVERTER, MODEL SB3000TL-US-22,240V JUSTED FOR TEMPERATURE, DISTANCE,AND , INV-3 INVERTER, DC/AC SMA INVERTER, MODEL SB5000TL-US-22,240V DERATING FACTORS. BKR-1 INV-1,AC CIRCUIT BREAKER MATCH COMBINER PANEL BRAND, 20A, 2-POLE 2.) ELECTRICAL CONDUIT TO BE MIN. PVC BKR-2 INV-1,AC CIRCUIT BREAKER MATCH COMBINER PANEL BRAND, 20A, 2-POLE SCHEDULE 40,ADJUST FOR SITE CONDITIONS. BKR-3 INV-1,AC CIRCUIT BREAKER MATCH COMBINER PANEL BRAND, 30A, 2-POLE 3.) ALL ELECTRICAL MATERIALS AND INSTAL- AC-CMB-1 AC COMBINER PANEL 250V,60A, NEMA-1, 1-PH,3-WIRE LATION METHODS TO COMPLY WITH NEC AND AC-DSC-1 AC DISCONNECT SWITCH (LINE TAP) 250v, 60A, NEMA-1, FUSE RATING:60A LOCAL CODE REQUIREMENTS. 4.) NOTE: GROUNDING ELECTRODE CON- ELECTRICAL LOAD SUMMARY DUCTOR TO BE#6 COPPER. DC CIRCUITS OP. CURRENT OP.VOLTAGE MAX.VOLTS S.S.C. ELECTRICAL LOAD SUMMARY TAG @STC @STC @ T-MIN @STC AC CIRCUITS PV-SA-1A 5.98 A DC 180 V DC 291 V DC 6.46 A DC PV-SA-1B 5.98 A DC 225 V DC 364 V DC 6.46 A DC VOLTAGE MAX.AC MAX. DC PV-SA-2A 5.98 A DC 225 V DC 364 V DC 6.46 A DC TAG POWER RANGE CURRENT CURRENT PV-SA-2B 5.98 A DC 225 V DC 364 V DC 6.46 A DC INV-1 3000 WATTS 211-264 VAC 15 A AC 22 A DC PV-SA-3A 5.98 A DC 360 V DC 583 V DC 6.46 A DC INV-2 3000 WATTS 211-264 VAC 15 A AC 22 A DC PV-SA-3B 5.98 A DC 360 V DC 583 V DC 6.46 A DC INV-3 5000 WATTS 211-264 VAC 22 A AC 30 A DC PROPOSED EQUIPMENT SPECIFICATIONS REVISIONS Ellen & Fred Wiederlight 50 Fred Street E 11 LOGIC' ' E 6 �`F Y New Suffolk, NY 1195 ELI�I[I�ATtN.G THE COST ENERGYOF 1.) INITIAL SUBMITTAL WITH APPLICATION Page 2 of 2 Drawing No: WIEDRLT-3LD1 Revision: 1 Revised: 6/09/2015 1 1, Pacific-o Engineering PC _ Engineering Consulting 700 Lakeland Ave, Suite 2B .- ] s _ Ph: 631-988-0000 Bohemia, NY 11716 Eat,„ — P Fax: 631-382-8236 www.pacificoengineering.com - C'= solar@pacificoengineering.com September 22, 2015 P a Town of Southold Z-e.. t Building Department 54375 Route 25, P.O. Box 1179 Southold, NY 11971 Subject: Solar Energy Installation for Ellen and Frederick Wiederlight Section: 117 50 Fred Street Block: 4 New Suffolk, NY 11956 Lot: 22 I have reviewed the roofing structure at the subject address.The structure can support the additional weight of the roof mounted system. The units are to be installed in accordance with the manufacturer's installation instructions. I have determined that the installation will meet the requirements of the 2010 NYS Building Code, and ASCE7-05 when installed in accordance with the manufacturer's instructions. Roof Section A B C D Mean roof height 12 ft 12 ft 19 ft 12 ft Pitch 8 in/12 8 in/12 8 in/12 8 in/12 Roof rafter 2x12 2x12 2x12 2x12 Rafter spacing 16 inch on center 16 inch on center 16 inch on center 16 inch on center Reflected roof rafter span 11.0 ft 5.9 ft 20.5 ft 4.1 ft Table R802.5.1(1)max allowable 23.8 ft 23.8 ft 23.8 ft 23.8 ft The climactic and load Information is below: CLIMACTIC AND Ground Wind Live load, point GEOGRAPHIC DESIGN Cate o Snow Load, Speed,3 pnet30 per type g ry sec gust, ASCE 7, pullout Fastener CRITERIA Pg mph psf load,lb Roof Section A C 20 120 30 412 (2)#14-13 x4.5"DPI concealer screws(3.5"min embedment) B 30 412 (2)#14-13 x4.5"DP1 concealer screws(3.5"min embedment) C 30 614 (2)#14-13 x4.5"DP1 concealer screws(3 5"min embedment) D 30 412 (2)#14-13 x4.5"DP1 concealer screws(3 5"min embedment) Weight Distribution OF NEW Y0,�, array dead load 3.5 psf 4.. ?ACIP/0 'f' load per attachment 440.0 lb T,..3 O CI- Subject roof has one layer of shingles •- '�", ,t'i%ci 4 tLi ,_1r 'y*•,,; a. w Panels mounted flush to roof no higher than 6 inches above surface. , „��` ,i h t r 0 Ralph Pacifico, PE n " � �� Professional Engineer �i 't 066A'6� Q/ Ral•,7®ifkoo, - si. On.- eer NY 0.-IMO':>P"' ' •'306 ENERGY GreenLogic,LLC Approved Ellen and Frederick Wiederlight 50 Fred Street New Suffolk,NY 11956 631-765-1139 Surface#A: Total System Size 11 445kW Array Size•4 251 kW 1 string of 8 and 1 string of 8 on SB-5000TL (shared with surface#D) 1 string of 5 and 1 string of 5 on SB-3000TL (shared with surface#B) Azimuth: 168° Pitch:34° �, Monitoring System: SunPower Panel/Array Specifications: Panel:SPR-E-20-327 Racking:UniRac SunFrame Panel:41 18"X 61.39" Array:23'3 75"X 14'2 17" Surface:32'2"X 16'6" Magic#:41.93" Legend: rn 13 SunPower 327W Panel UniRac SunFrame Rail • 27 Eco-Fasten quickfoot 2x12"Douglas Fir Rafter 16" OC Notes. Number of Roof Layers: 1 Height above Roof Surface 4" Materials Used:UniRac,Eco-Fasten, SunPower,SMA Added Roof load of PV System:3 5psf Engineer/Architect Seal: OF �1EW YO � pACIFjcO Q- Q i•- cAN tis 066\6 • ' o PROFESS�O� Drawn By ADL Drawing#1 of 14 Date:7/31/2015 REVS A Drawing Scale.3/16"=1 0' _iENERGYi -.1 t" E LOG C® GreenLogic,LLC Approved Ellen and Frederick Wiederlight 50 Fred Street New Suffolk,NY 11956 631-765-1139 Surface#A: Total System Size 11 445kW Array Size:4 251 kW 1 string of 8 and 1 string of 8 on SB-5000TL (shared with surface#D) 1 string of 5 and 1 string of 5 on SB-3000TL (shared with surface#B) Azimuth: 168° Pitch 34° �, . Monitoring System: • « - 7• 21' . : ,)01 . SunPower : \ Panel/Array Specifications: Panel:SPR-E-20-327 Racking: UniRac SunFrame / ` Panel:41.18"X 61.39" ^\ Array:23'3.75"X 14'2.17" i Surface:32'2"X 16'6" 1/ Magic#:41.93„ Legend: -71, ,N\•/: •� �' • 13 SunPower 327W Panel UniRac SunFrame Rail • 27 Eco Fasten gwckfoot ' ' 7 \ �r ii 2x12"Douglas Fir Rafter 16" � \. Notes ; j Number of Roof Layers. 1 ,dh.liHeight above Roof Surface'4" . : ' Materials Used.UniRac,Eco-Fasten, . • SunPower,SMA + _ Added Roof load of PV System:3.5psf Engineer/Architect Seal: OF NEw Y°R 4r ?I\CIF,CO lk Q ,, Z1iL41I ) �� PRO FESS\' . Drawn By:ADL Drawing#2 of 14 Date:7/31/2015 REV A Drawing Scale:3/16"=1 0' COGREENLOGIC® ENERGY GreenLogic,LLC Approved Ellen and Frederick Wiederlight 50 Fred Street New Suffolk,NY 11956 631-765-1139 Surface#A: Total System Size 11 445kW Array Size 4 251 kW 1 string of 8 and 1 string of 8 on SB-5000TL (shared with surface#D) 1 string of 5 and 1 string of 5 on SB-3000TL (shared with surface#B) Azimuth: 168° Pitch:34° Monitoring System: IRP, SunPower Panel/Array Specifications: 2 Panel:SPR-E-20-327 Racking:UniRac SunFrame Panel:41.18"X 61 39" " Array:23'3 75"X 14'2.17" Surface.32'2"X 16'6" Magic#•41.93" Legend: iffr 13 SunPower 327W Panel ® UniRac SunFrame Rail 1 • 27 Eco-Fasten quickfoot : B 2x12"Douglas Fir Rafter 16" O.C. Notes: 1 Number of Roof Layers: 1 Height above Roof Surface 4" Materials Used:UniRac,Eco-Fasten, SunPower,SMA Added Roof load of PV System:3 5psf Engineer/Architect Seal: OF SEW 'CIA- ((/' ?ACIP/0o f, tico �_i�.t • Com ! to 0661• Qv PROFES4 Drawn By:ADL Drawing#3 of 14 Date:7/31/2015 REV.A Drawing Scale:3/16"=1.0' ,4GREENL 11C® (t,'" \‘' ENERGY GreenLogic,LLC Approved Ellen and Frederick Wiederlight 50 Fred Street New Suffolk,NY 11956 631-765-1139 Surface#B: Total System Size 11 445kW Array Size 1.635kW 1 string of 5 and 1 string of 5 on SB- 3000TL(shared with surface#A) Azimuth:86° Pitch:34° Monitoring System: �� SunPower Panel/Array Specifications: Panel:SPR-E-20-327 Racking UniRac SunFrame Panel:41.18"X 61.39" Array: 15'7.5"X 7'2.17" Surface:26'2"X 9'7" Magic#:41.93" Legend: In 5 Sun Power 327W Panel ® UniRac SunFrame Rail • &I1MM13 Eco-Fasten quickfoot B11 2x12"Douglas Fir Rafter 16" O.C. Notes: Number of Roof Layers: 1 Height above Roof Surface.4" Materials Used UniRac,Eco-Fasten, SunPower,SMA Added Roof load of PV System:3.5psf Engineer/Architect Seal: 014EWY01 !` cACIF/ L•� � . � ;; her: �; /s�O 066��\O�PF PROFESS Drawn By ADL Drawing#4 of 14 Date 7/31/2015 REV A Drawing Scale:3/16"=1 0' `¥x „rte ENERGY GreenLogic,LLC Approved Ellen and Frederick Wiederlight 50 Fred Street New Suffolk, NY 11956 631-765-1139 Surface#B: Total System Size 11 445kW Array Size 1.635kW 1 string of 5 and 1 string of 5 on SB- 3000TL(shared with surface#A) Azimuth 86° Pitch 34° I Monitoring System: via; j � ' I�jj '�i_.. SunPower I 141 I'1 1 jam I 1 Panel/Array Specifications: 1,� I,I Panel:SPR-E-20-327'c I ' I'I ( l I Racking• UniRac SunFrame I .'I I 1,I,1 1 1 Panel:41.18"X 61.39" j �"'jpitrimil I � � I/ � Array: 15'7.5"X T 2 17..I I I i j1 Surface•26'2"X 9'7" I II Magic# 41.93" I 11UIIU!IIdU...1'IiI. iAI /1 'j 1Legend: I 1 I � I1j I 1 I ® 5 SunPower327W Panel j1I , . ... I 1 I 1 , UniRacSunFrame Rail II 1 1 �.i.1.1.�.i.l.I.,.i.1■1 ! I I I& • 13 Eco-Fasten quickfoot Fi 1] 2x12"Douglas Fir Rafter 16" O C. Notes: Number of Roof Layers: 1 Height above Roof Surface.4" Materials Used:UniRac, Eco-Fasten, SunPower,SMA Added Roof load of PV System:3.5psf En9I Seal: SEW t 0,0 `r d- / ''' ""? 4 w Ad P /1*S4-,,, 116 1.11 91, S 060- ` F�PROFESS\04 . Drawn By ADL Drawing#5 of 14 Date:7/31/2015 REV:A Drawing Scale.3/16"=1 0' f k,,, E L OC'.„ ” ENERGY GreenLogic,LLC Approved Ellen and Frederick Wiederlight 50 Fred Street New Suffolk, NY 11956 631-765-1139 Surface#B: Total System Size 11.445kW Array Size. 1.635kW 1 string of 5 and 1 string of 5 on SB- 3000TL(shared with surface#A) Azimuth 86° Pitch:34° Monitoring System: 11 SunPower prIV4A4MVP1 Panel/Array Specifications: Panel:SPR-E-20-327 Racking* UniRac SunFrame Panel:41.18"X 61 39" " Array: 15'7 5"X 7'2.17" Surface:26'2"X 9'7" Magic#:41.93" Legend: V .\VW le rA r n 5 SunPower 327W Panel ® UniRac SunFrame Rail • 13 Eco-Fasten quickfoot B 2x12"Douglas Fir Rafter 16" O.0 Notes: Number of Roof Layers: 1 Height above Roof Surface:4" Materials Used UniRac, Eco-Fasten, SunPower,SMA Added Roof load of PV System:3 5psf Enginee..,--_-' -_tSeal: OF E W YO C/3 64 e'WV / ' -C-1 VIPAlk--'''*-<fr ' - liP 066'0' Q ' PROFESS Drawn By:ADL Drawing#6 of 14 Date:7/31/2015 REV:A Drawing Scale 3/16"=1.0' GGREENL4C® ERGY GreenLogic,LLC Approved Ellen and Frederick Wiederlight 50 Fred Street New Suffolk, NY 11956 631-765-1139 Surface#C: Total System Size. 11.445kW Array Size:2.943kW 1 string of 5 and 1 string of 4 on SB- 3000TL Azimuth:86° Pitch 34° Monitoring System: %�' SunPower Panel/Array Specifications: Panel:SPR-E-20-327 Racking:UniRac SunFrame Panel.41.18"X 61 39" Array 12' 10 75"X 10'8.2" O Surface:50'6"X 27'2" O O Magic#:41 93" Legend: Irrl 9 SunPower Panel UniRac SunFrame Rail M*-M1 • 25 Eco-Fasten Quickfoot 2x12"Douglas Fir Rafter 16" O C. Notes: Number of Roof Layers 1 Height above Roof Surface MaterialsUniRac,Used: Eco-Fasten, SunPower,SMA Added Roof load of PV System:3.5psf Engineer/Architect Seal: W yo pAC/Fj 14V •: tet VAIrtti jot - 06055 Y �'ROFESS\°� Drawn By:ADL Drawing#7 of 14 Date:7/31/2015 REV:A Drawing Scale:5/32"=1 0' Q <:,. ENERGY GreenLogic,LLC Approved Ellen and Frederick Wiederlight 50 Fred Street New Suffolk, NY 11956 631-765-1139 Surface#C: Total System Size: 11.445kW Array Size:2.943kW ' 1 string of 5 and 1 string of 4 on SB- • 3000TL • Azimuth'86° ' Pitch 34° Monitoring System: V . SunPower • Panel/Array Specifications: Panel.SPR-E-20-327 . Racking:UniRac SunFrame • Panel:41.18"X 61.39" . Array 12' 10.75"X 10'8 2" • Surface:50'6"X 27'2" b 0 4—�,� / Magic#:41.93,. ' .;� Legend: / 9 SunPower 327W Panel UmRac SunFrame Rail ��' • 25 Eco-Fasten Qwckfoot • . , \ . 2x12"Douglas Fir Rafter 16" 0C. Notes: ` �, Number of Roof Layers. 1 /'� Height above Roof Surface'4" • Materials Used UniRac,Eco-Fasten, SunPower,SMA Added Roof load of PV System:3.5psf Engineer/Architect Seal: �T,&NC.QN PAC/, 0 -1- - lZ9 is :' -'}tom 02 ,, �2 P&OFESS\O� Drawn By:ADL Drawing#8 of 14 Date:7/31/2015 REV.A Drawing Scale.5/32"=1.0' GREENL GC® ENERGY GreenLogic,LLC Approved Ellen and Frederick Wiederlight 50 Fred Street New Suffolk,NY 11956 631-765-1139 Surface#C: Total System Size: 11.445kW Array Size.2 943kW 1 string of 5 and 1 string of 4 on SB- 3000TL Azimuth:86° Pitch:34° Monitoring System: SunPower Panel/Array Specifications: Panel SPR-E-20-327 Racking UniRac SunFrame Panel 41.18"X 61 39" Array: 12'10.75"X 10'8.2" O Surface 50'6"X 27'2" O OAmit Magic# 41 93" Legend: 9 SunPower 327W Panel UniRac SunFrame Rail kiMM4:2 • 25 Eco-Fasten Quickfoot 2x12"Douglas Fir Rafter 16" .M4 _ Notes. Number of Roof Layers:1 Height above Roof Surface. hIWMaterials Used:UniRac,Eco-Fasten, SunPower,SMA Added Roof load of PV System.3.5psf Engineer itect Seal: of OE W YO pAC/Fid, '- vti..0-pi tor 41 -411 �kS, 060 w PROFESS\O Drawn By:ADL Drawing#9 of 14 Date:7/31/2015 REV.A Drawing Scale:5/32"=1 0' EE 1 ® ENERGY GreenLogic,LLC Approved Ellen and Frederick Wiederlight 50 Fred Street New Suffolk,NY 11956 631-765-1139 Surface#D: Total System Size 11.455kW Array Size:2 616kW 1 string of 8 and 1 string of 8 on SB- 5000TL(shared with S#A) Azimuth: 168° Pitch:34° ivj Monitoring System• SunPower Panel/Array Specifications: Panel:SPR-E-20-327 Racking:UniRac SunFrame Panel:41.18"X 61 39" Array 30'10 992"X 7'7.515" .. Surface 45'X 8'3" / . Magic#.41.93" Legend: irr 8 SunPower 327W Panel UniRac SunFrame Rad • 21 Eco-Fasten Qwckfoot B 2x12"Douglas Fir Rafter 16" O.C. Notes: Number of Roof Layers: 1 Height above Roof Surface:4" Materials Used:UniRac,Eco-Fasten, SunPower,SMA Added Roof load of PV System:3.5psf Engineer/Architect Seal: F\ASW Yp,, � ,./ Q p.0 I F/CO /� rp Cr 4 ,'fit -' I. •i „. - • ..v. \,,,..:,,,,, \ NIL• - C) p66N. =w `9.6 PROF, C.0 Drawn By:ADL Drawing#10 of 14 Date:7/31/2015 REV:A Drawing Scale:5/32"=1.0' GREEN LOGIC® ENERGY GreenLogic,LLC Approved Ellen and Frederick Wiederlight 50 Fred Street New Suffolk,NY 11956 631-765-1139 Surface#D: Total System Size' 11.455kW Array Size:2.616kW 1 string of 8 and 1 string of 8 on SB- 5000TL(shared with S#A) Azimuth: 168° Pitch:34° CP% Monitoring System: SunPower Panel/Array Specifications: Panel:SPR-E-20-327 Racking UniRac SunFrame Panel:41 18"X 61.39" Array 30'10.992"X 7'7.515" Surface:45'X 8'3" Magic#:41.93" Legend: ;,• 6,, 8 SunPower 327W Panel ; � . UniRac SunFrame Rail • • 21 Eco-Fasten Quickfoot . . �./ ` 2x12"Douglas Fir Rafter 16" / O.0 • / , Notes: \ / \ Number of Roof Layers 1 '• A + ` �✓ \'�9 u f ` � �n Height above Roof Surface 4" Materials Used•UniRac,Eco-Fasten, SunPower,SMA Added Roof load of PV System:3.5psf Engineer/Architect Seal: * /4E W 3? r, Y, w 4 w fAito 11§/ C 1, s�f/r a T2s �O66��� Qv c%PROFESs\O Drawn By:ADL Date:7/31/2015 Drawing Scale:5/32"=1.0' GREE N .� .. ENERGY GreenLogic,LLC Approved Ellen and Frederick Wiederlight 50 Fred Street New Suffolk,NY 11956 631-765-1139 Surface#D: Total System Size: 11 455kW Array Size 2.616kW 1 string of 8 and 1 string of 8 on SB- 5000TL(shared with S#A) Azimuth.168° Pitch:34° Monitoring System. I� SunPower Panel/Array Specifications: Panel:SPR-E-20-327 Racking:UniRac SunFrame Panel:41.18"X 61 39" Array:30'10 992"X 7'7.515" Surface 45'X8'3" 6 Magic#.41.93" Legend: rn 8 SunPower 327W Panel 6 \ UniRac SunFrame Rail • 21 Eco-Fasten Quickfoot [1 2x12"Douglas Ar Rafter 16" O.C. Notes: Number of Roof Layers 1 Height above Roof Surface 4" Materials Used.UniRac,Eco-Fasten, SunPower,SMA Added Roof load of PV System:3.5psf Engineer/Architect Seal: ofNEW y . QN Pacicco'S' , 0 �� r 06.z SAO 066.1 pROFESS\O' Drawn By:ADL Drawing#12 of 14 Date:7/31/2015 REV•A Drawing Scale 5/32"=1.0' �� / Green,. 18" Service Walkway Logic,LLC Approved /' Ellen and Frederick WiederlightENER Y 50 Fred Street New Suffolk,NY 11956 I 631-765-1139 I I Total System Size:11 445kW 1 string of 8 and 1 string of 8 on SB-5000TL / 1 string of 5 and 1 string of 5 on SB-3000TL / 1 string of 5 and 1 string of 4 on SB-3000TL / / Azimuth. 168° //// / Pitch:34° , c, • Monitoring System: �� SunPower " Panel/Array Specifications: Panel:SPR-E-20-327 O 9 SunPower 327W Racking:UniRac SunFrame Panels Panel:41.18"X 61 39" 3 SMA Inverters Array:23'3.7"x 14'2.17" located In South Service Surface:32'2"X 16'6" WalkwayMagic#:41.93" East Corner of Legend: •sement ® 35 SunPower 327W Panel ® UniRac SunFrame Rail 114FPri • 86 Eco-Fasten Quickfoot [1 1] 2x12"Douglas Fir Rafter 16" /18" o Notes Syl / Number of Roof Layers' 1 l / Height above Roof Surface 4" ( XMaterials Used: UniRac,Eco-Fasten, \ tl I SunPower,SMA // 4 \ I Added Roof load of PV System:3.5psf // `\ Engineer/Architect Seal: /' \� pF NEVI/Y '/' \\` ... ��'�NPAC/R�c0'0Q.� ' ` ilsve' L *. 1 , , 6,,,,,,,,,,,,„ Li., • , / / \ .k el/ m2 � _ ts ZW>.°'.?< \ Ve / / OFESS\O 13 SunPower 5 SunPower Drawn By:ADL Drawing#13 of 14 • 18"Service 8 SunPower 327W Panels 327W Panels 327W Panels Date.7/31/2015 REV A Walkway Drawing Scale: 1/8"=1.0' c4 S I O C® ENERGY GreenLogic,LLC Approved Ellen and Frederick Wiederlight 50 Fred Street New Suffolk, NY 11956 631-765-1139 Total System Size 11 445kW 1 string of 8 and 1 string of 8 on SB-5000TL 1 string of 5 and 1 string of 5 on SB-3000TL _1__..__ ___.___.,__._... ...___..-.—.__...__ ___._. _—_ .-r" __,___ —____..�.___.—.._ 1 stung of 5 and 1 string of 4 on SB-3000TL imolai list Qy. 1 MI Weld list Qv. 1 i j Azimuth. 168° _ Pitch:34° __.._--_— —.—_—__ ._—_ __ __ _._.__�_ _—_ —_.___._- __—.- _ —.__-' -- __...__ ._____ _ __ Monitoring System' til, w i — SunPower (—_ Panel/Array Specifications: - f �— Panel SPR E-20-327 Racking:UniRacSunFrame ED-Fa Qad600t�eF9a e ffi �___...---!_-.---------_-._ �___— —t.—.---{— _--._..___ Panel.41.18"X 61 39" _ _ l ' l Array:23'3.7"X 14'2.17" EmFalQaddmtaumrr�ods � ffi._�-----._—�- i. __.------- i— Surface:32'2"X 16'6„ Eco-FalevaidiatFl iirg E61 Magic#.41 93" #14134511 Ccruesie SaeN l 172 it ____._.-�—_---- Legend: r_..—._____,—___..m _ _�.__ -.— 35 SunPower 327W Panel ________ __—_____ _.__ ___._____,._.. _a____.._—._—._ _._ _._.__..._ ___ . _ ____--�- .._ UniRac SunFrame Rad • 86 Eco-Fasten Quickfoot 2x12"Douglas Fir Rafter 16" --,- 1 [I I} Notes _ _____--- `— ___ Number of Roof Layers 1 _ i -f—_ Height above Roof Surface 4" Materials Used:UniRac,Eco-Fasten, 1 E } SunPower,SMA f - -- -- - _ { Added Roof load of PV System:3.5psf l Z----•--3 -----t--- ------ Engineer/Architect Seal: ` ‘EWy0 ,L��_ IDACIAjc itQ - r� /�°��,` ,� '' C7 n 1 lat//.1.,.,; ,0 44.1 ti 06. Qv pROFEss\O Drawn By:ADL Drawing#14 of 14 Date:7/31/2015 REV:A Drawing Scale:1/8"=1.0' f SUNFRAME® ., . ., _ , Code-Compliant Installation Manua � min 0 Su n '•:= .r <, � a." �,.wy� . W� s: ..� a '-'''''''H.. 4,,,,,,,‘,„,...„..„,,,...„4„....„.„ ,.._,,-, ,,,,,,,,, .''''' ,4„, ''' 1 e"� "`� �',` .fd ''`�"• �-7� a .!!�' "'Y, .,mow '_'tea' � .+^' �_.,. 2 y . ...�»* .,,,c r is rva r3'�` % :' . T. - �• yL' by ", 7.7.,r. `�, -i4, y�.. N, Ott Y➢ ^:<.,v '''. 4.F.' '-''''. ‘4,(V--. ?',r 8\ `\ of �e Fx, a k; � �y rrtmm ,.,I +1 s "mac f-;.0 ;:.�*+�,..,/ !a"��� 0, .....v.„....c... Table of Contents i.Installer's Responsibilities 2 3 Part I.Procedure to Determine the Total Design Wind Load 3 43 Pii Part II.Procedure to Select Rail Spanand Rail Type 10 Part III.Installing SunFrame 14 Pub 080703-1cc :!: u N I RAC July 2008 Bright Thinking in Solar .8)2008 by'Unirac,Inc. Unirac welcomes input concerning the accuracy and user-friendliness of this publication.Please write to publications@unirac.com. All rights t eserved. . r :is U N I RAC Unirac Code-Compliant Installation Manual SunFrame i. Installer's Responsibilities Please review this manual thoroughly before installing your SunFrame offers finish choices and low,clean lines that SunFrame system. become as natural a part of a home as a skylight.It delivers the This manual provides(1)supporting documentation for installation ease you've come to expect from Unirac. building permit applications relating to Unirac's SunFrame Whether for pitched roofs or parking roof structures, Universal PV Module Mounting system,and(2)planning and SunFrame was designed from the outset to promote superior assembly instructions for SunFrame aesthetics.Modules are flush mounted in low,gap-free rows, SunFrame products,when installed in accordance with this and visible components match clear or dark module frames. bulletin,will be structurally adequate and will meet the structural requirements of the IBC 2006,IBC 2003,ASCE 7- 02,ASCE 7-05 and California Building Code 2007(collectively referred to as"the Code").Unirac also provides a limited warranty on SunFrame products(page 24). 1 l AThe installer is solely responsible for: • Complying with all applicable local or national building codes, including any that may supersede this manual; • Ensuring that Unirac and other products are appropriate for the particular installation and the installation environment; • Ensuring that the roof,its rafters, connections, and other structural support members can support the array under all code level loading conditions (this total building assembly is referred to as the building structure); • Using only Unirac parts and installer-supplied parts as specified by Unirac (substitution of parts may void the warranty and invalidate the letters of certification in all Unirac publications); • Ensuring that lag screws have adequate pullout strength and shear capacities as installed; • Verifying the strength of any alternate mounting used in lieu of the lag screws; • Maintaining the waterproof integrity of the roof, including selection of appropriate flashing; • Ensuring safe installation of all electrical aspects of the PV array; and • Ensuring correct and appropriate design parameters are used in determining the design loading used for design of the specific installation. Parameters, such as snow loading,wind speed, exposure and topographic factor should be confirmed with the local building official or a licensed professional engineer. F axe Nk. J 2 an SunFrame Unirac Code-Compliant Installation Manual 1r UNI I A Part I. Procedure to Determine the Design Wind Load [1.1.] Using the Simplified Method -ASCE 7-05 The procedure to determine Design Wind Load is specified for more clarification on the use of Method I.Lower design by the American Society of Civil Engineers and referenced in wind loads may be obtained by applying Method II from ASCE the International Building Code 2006. For purposes of this 7-05.Consult with a licensed engineer if you want to use document,the values,equations and procedures used in this Method 1I procedures. document reference ASCE 7-05,Minimum Design Loads for The equation for determining the Design Wind Load for Buildings and Other Structures. Please refer to ASCE 7-05 if components and cladding is: you have any questions about the definitions or procedures presented in this manual.Unirac uses Method 1,the s AKztl Simplified Method,for calculating the Design Wind Load for Pnet(p f)= pnet3o pressures on components and cladding in this document. Pnet(psf)=Design n Wind Load The method described in this document is valid for flush,no tilt,SunFrame Series applications on either roofs or walls. A=adjustment factor for height and exposure category Flush is defined as panels parallel to the surface(or with no more than 3"difference between ends of assembly)with no Kzt=Topographic Factor at mean roof height,h(ft) more than 10"space between the roof surface,and the bottom of the PV panels. I=Importance Factor This method is not approved for open structure calculations. pnet3o(psf) =net design wind pressure for Exposure B,at height Applications of these procedures is subject to the following =30,I=1 ASCE 7-05 limitations: 1.The building height must be less than 60 feet,h<60. See note for determining h in the next section. For installations You will also need to know the following information: on structures greater than 60 feet,contact your local Unirac Distributor. Basic Wind Speed=V(mph),the largest 3 second gust of wind in 2.The building must be enclosed,not an open or partially the last 50 years. enclosed structure,for example a carport. h(ft)=total roof height for flat roof buildings or mean roof 3.The building is regular shaped with no unusual geometrical height for pitched roof buildings irregularity in spatial form,for example a geodesic dome. Effective Wind Area(sf) =minimum total continuous area of 4.The building is not in an extreme geographic location such modules being installed as a narrow canyon or steep cliff. 5.The building has a flat or gable roof with a pitch less than 45 Roof Zone=the area of the roof you are installing the pv system degrees or a hip roof with a pitch less than 27 degrees. according to Figure 2,page 5. 6.If your installation does not conform to these requirements Roof Zone Setback Length=a(ft) please contact your local Unirac distributor,a local professional engineer or Unirac Roof Pitch(degrees) If your installation is outside the United States or does not Exposure Category meet all of these limitations,consult a local professional engineer or your local building authority.Consult ASCE 7-05 [1.2.] Procedure to Calculate Total Design Wind The procedure for determining the Design Wind Load can be Step 2:Determining Effective Wind Area broken into steps that include looking up several values in Determine the smallest area of continuous modules you will different tables. be installing. This is the smallest area tributary(contributing load)to a support or to a simple-span of rail.That area is the Step 1:Determine Basic Wind Speed,V(mph) Effective Wind Area. Determine the Basic Wind Speed,V(mph)by consulting your local building department or locating your installation on the maps in Figure 1,page 4. Yea. 3 ;: Unirac Code-Compliant Installation Manual SunFrame tr Atiftforti } #�"111 lai 42 mit ri �. ' [#�/s4{44) ,0 �►a 4 mai * s yt.rt.r 100(45) 85mph Mir ,s r 41111 � `+ S 1,411 {36 mIs) `t1 „., # +1 Ntipt hi. � OW 111 144114h 4 4 714{49) itraw441 illii .44111ty j " ■M"t `{.trrrr!*K >t }!� 120(54) R "Mau sst >b 'rari ,�y� ■McimPtil $,'y r 1 i � d C 1fa(4"1/1 O m/s ��f r., i"{"E:'titted tir +T li 90 mph 'A, ea.: itrrrt,...a4 i C. 7,i rr tt r1r, ¢ .0614 lip if"...i.1141,11 iii‘,. r!irire.��► !�!'1a11'1ir L"::ISR 4s i�s tr'•f•. ass�,r 'pm ��ttr�sv { } 1�1M tiw ari i t" t ryn • ../� 2'a'1....*t .� 134 59 1h,,,8 i, othirr ii .i t�Yw W R "'10 ,044.a.4T�� ♦ ' '144 63 ‘44411"1111-w- 't4 I'm"' if M ■ 4a w.i �: j a,YVM�'' r,' { } *+ss i 111M�NtivigroPirr ....'�4�'t .� cif! 7..........,air siv...„ nu. it ir atil .-ii r igloo 44:o '� j, q� IrM iii iklt M`iY zwi�* *i.4a,xi le ,t'�r ! .r .,.�� , +�� Miles per hour • ani iE ata 4it ana 4 2 ■111 ■ lrti f;►lAuw tt wi" 1tifita� `�.t ��is ..a �'lfiggivoicou�p+� ���, �4��'1 �,. ♦,�*.,. ��,t. (meters per second) 07alug si ' tfllpkl iV j c�tt.lut ,tet* w VIIi. 1irl a414 1,ter bIx 1a4, -'4.1v---‘ r`lroli 1lr. 130 58 Figure 1.Basic Wind Speeds.Adapted and �a,,,M��.�,ir�,,��^�.�;;� `-�iYi applicable to ASCE 7-05.Values are nominal a +'��'.,,t 40(63) -`* 14(3(1 t 1 140(63) des' 3-second gust wind speeds at 33 feet , • ��'Ol �""►t 4 above ground for Exposure Category C jl �� + ts 150(67) 90(40) i '+ . Special Wind Region 2-1 100(45) 130(54) 110(49)120(54) Step 3:Determine Roof/Wall Zone The Design Wind Load will vary based on where the installation is located on a roof. Arrays may be located in more than one roof zone. Using Table 1,determine the Roof Zone Setback Length,a(ft), according to the width and height of the building on which you are installing the pv system. Table I.Determine Roof/Wall Zone,length (a) according to building width and height a= 10 percent of the least horizontal dimension or 0.4h,whichever is smaller,but not less than either 4%of the least horizontal dimension or 3 ft of the building. Roof Least Horizontal Dimension(ft) Height(ft) 10 15 20 25 30 40 50 60 70 80 90 100 125 150 175 200 300 400 500 _._ ._,..10 3 _ .. 3-. . 3" 3 _ .- q _4 __4 4 --¢.._' 4.. 4 5._— 6..�� 7.. $ �?. ..).b. _2Q 15 3 3 3 3 34 5 6 6 6 6 6 6 6 7 8 12 16 20 20 3. 3 3 3 '.3. '•_. 4. 5 _. 6 7 8_. _. 8 8 .8 8 8 8. 12 16 20 25 3 3 3 3 3 4 5 6 7 8 9 10 10 10 10 10 12 16 20 39 _. 3 ._..3 3 3 3 _�w_4- ..5.. ,.6.. ._, 7. ...8 .:'9 l0 12 12 12 ' 12 ,. 12 Ib _•20 35 3 3 3 3 3 4 5 6 7 8 9 10 12.5 14 14 14 14 16 20 40 3 -,:"3—_- 3,_ 3 __3 4 5-7 -6 7 _8 _-;9. 10- 12.5 _15 .16 _16 16 . 16 20, 45 3 3 3 3 3 4 5 6 7 8 9 10 12.515 17.5 18 18 18 20 50 .. ...,,. 3 3-. 3 3 3 4 5 6 7 8 9 _ 10' 12.5 _ 15 17.5 20 20 20. . 20,. 60 3 3 3 3 3 4 5 6 7 8 9 10 12.5 15 17.5 20 24 24 24 Source: ASCE/SE1 7-05, Minimum Design Loads for Buildings and Other Structures,Chapter 6,Figure 6-3, p.41 Page 4 CIO SunFrame Unirac Code-Compliant Installation Manual :® I r C Step 3:Determine Roof Zone(continued) Using Roof Zone Setback Length,a,determine the roof zone locations according to your roof type,gable,hip or monoslope. Determine in which roof zone your pv system is located,Zone 1,2,or 3 according to Figure 2. Figure 2.Enclosed buildings,wall and roofs am d "'N' Flat Roof , - Hip Roof(7° < 8 5 27°) %r ,,,,,P44; . �,,, s4419": *. l .,. , a ,�''� ,. a '---,„,„,a" c " ,_` < \ r ' a �',�a • te, Gable Roof(8 5 7°) ,,,, '°`' ,,, Gable Roof(7° < 8 <_ 45°)y. ``" " �•, �+`f"° mss iti' ,g awe 'Mc R r' z / �r}' 1 a / .-, /, w, ' '*, a a ,° -, . .,, Interior Zones End Zones :. • Corner Zones Roofs-Zone I/Walls-Zone 4 _ ' Roofs-Zone 2/Walls-Zone 5 Roofs-Zone 3 Source: ASCEISEI 7-05, Minimum Design Loads for Buildings and Other Structures,Chapter 6, p.41. Step 4:Determine Net Design Wind Pressure,pnetao Both downforce and uplift pressures must be considered (psf) in overall design. Refer to Section II,Step 1 for applying Using the Effective Wind Area(Step 2),Roof Zone Location downforce and uplift pressures.Positive values are acting (Step 3),and Basic Wind Speed(Step 1),look up the toward the surface.Negative values are acting away from the appropriate Net Design Wind Pressure in Table 2,page 6. Use surface. the Effective Wind Area value in the table which is smaller than the value calculated in Step 2.If the installation is located on a roof overhang,use Table 3,page 7. Pap 5 :FUN I RAC Unirac Code-Compliant Installation Manual SunFrame Table 2.pnet30(psi) Roof and Wall BasicWand Speed,V(mph) 90 100 110 120 130 140 150 170 Effective Wind Area Zone (st) Downforce Uplift Downforce Uplift Downforce 'Uplift i Downforce Uplift Downforce Uplift Downforce Uplift rpownforce Uplift Downforce Uplift I 10 5.9 -14.6 1 7.3 -18.0 s 8.9 21,8 10.5 -25.9 12.4 -30.4 14.3' -35.3 1 16.5 -40.5 21.1 -52.0 I 20 5.6 -14.2 ; 6.9 -17.5 8.3 -21.2 9.9 -25.2 s 11.6 -29.6 13.4 -34.4 15.4 -39.4 19.8 -50.7 al I 50 5.1 -13.7 6.3 -16.9 , 7.6 -20,5 , 9.0 -24.4 10.6; -28.6 12.3 -33.2 14.1 -38.1 18.1 -48.9 L I 100 4.7 -113 5.8 -16.5 , 7.0 -19.9 8.3 -23.7 9.8 • -27.8 11.4 -32.3 13.0 -37.0 16.7 -47 6 17 { • 2 10 5.9 . -24.4 7.3 -30.2 I 8,9 -36.5 10.5 -43.5 1 12.4 -501 14.3 -59.2 1 16,5 -67,9' 21.1 -87.2 • 2 20 5.6 -21.8 ' 6.9 -27.0 8.3 -32.6 9.9 -38.8 1 11.6 -45.6 ` 13.4 -52.9 ` 15.4 -60.7 19.8 -78.0 c 2 50 5.1 -18.4 6.3 -22.7 , 7.6 -27.5 ' 9.0 -32.7 10.6 -38.4 12.3 -44.5 14.1. -51.1 18.1 -65.7 c 2 100 4.7 -15.8 5.8 -19.5 7.0 -23,6 8.3 -28.1 ' 9.8 -33.0 ' 11.4 -38.2 13.0 -43,9; 16.7 -56.4 re• 3 10 5.9 -36.8 7.3 -45.4 , 8.9 -55.0 10.5 -65.4 12.4 -76.8 14.3 -89.0 16.5 -102.2 21.1 -131.3 3 20 .5.6 -30.5 - 6.9 -37.6 8.3 -45,5 .• 9.9 -54.2 111.6- -63.6 13.4 -73.8 15.4 -84.7 19.8 -108.7 3 50 5.1 -22.1 6.3 -27.3 1 7.6 -33.1 1 9.0 -39.3 10.6 '-46:2 12.3 -53.5 1 14.1 -61.5! 18.1 -78.9 3 100 4.7 -15.8`1 5.8 -19.5 1 7.0 23.6^ 8.3 -28.1 ' 9.8" -33.0 ' 11.4 -38.2 1 13.0 -43,9'•' 16.7 -56.4 I 10 8.4 -13.3 10.4 -16.5 12.5 -19.9 149 -23.7 17.5' -27.8 20.3 -32.3 23.3 -37.0, 30.0 -47.6 I 20 7.7 -13.0 9.4 -16.0 '11.4 -19.4' 13.6 -23.0 ' 16.0 -27.0 18.5 -31.4 21.3 -36.0' 27.3 -46.3 iv I 50 6.7 -12:5 ; 82 -15.4 10.0 -18.6 ? 11.9 -22.2 13.9, -26.0 ' 16.1 -30.2 ' 18.5 -34.6 23.8 -44.5 toll' I 100 5.9. -12.1 1 7.3 -14.9 } 8.9 -18.1 10.5 -21.5 l 12.41 -25.2 14.3 -29.3 16.5 -33.6; 21.1 -43.2 n 2 10 8.4 -23.2 10.4 -28.7 L12.5 -34.7 14.9 -41.3 17.5' -48.4 20.3 -56 2 23,3 -64.5 1 30.0 -82.8 N 2 20 7.7 -21.4 " 9.4 -26.4 11.4 -31.9 13.6 -38.0 16.0' -44.6 18.5 -51.7 21.3 -59.3 27.3 -76.2 • 2 50 6.7 -18.9 8.2 -23.3 110.0 -28.2. : 11.9 -33.6 ; 13.9 -39.4 16.1 -45.7 18.5 -52.5 23.8 -67.4 • 2 100 5.9' -17.0 , 7.3 -21.0 i 8.9 -25.5 10.5 -30.3 3 12.4 -35.6 14.3 -41.2 16.5 -47.3 21.1 -60.8 3 10 8.4 -34.3 10.4 -42.4 12.5 -51.3 14.9 -61.0 ; 17.5 ,-71.6 t 20.3 -83.1 £'23.3 -95.4; 30.0 -122.5 3 20 7.7 -32.1' 9.4 -39.6 11.4 -47.9 13.6 -57.1 16.0 -67.0 18.5 -77.7 '21.3 -89.2 1 27.3 -114.5 3 50 6.7 -29.1 8.2 -36.0 ;10.0 -43:5 11.9 -51.8 13.9 -60.8 16.1 -70.5 18.5 -81.0 23.8 -104.0 3 100 5.9 -26.9 7.3 -33.2 8.9 -40.2 10.5 -47.9 12.41 -56.2 14.3 -65.1 16.5 -74.8= 21.1 -96.0 I 10 13.3 -14.6 ; 16.5 -18.0 ;19.9 -21.8 23.7 -25.9 .27.8 -30.4 32.3 -35.3 '37.0 ,-40.5 f 47.6 -52.0 I 20 '13.0 -13.8 16.0 -17.1 ;19.4 -20:7 23.0 -24.6 27.0 -28.9 31.4 -33 5 36.0, ' -38.4 46.3 -49 3 a I 50 12.5 -12.8 < 15.4 -15.9 18.6 -19.2 22.2 -22.8 ' 26.0' -26.8 30.2 -31.1 34.6 -35.7' 44.5 -45.8 • I 100 12.1 -12.1 , 14.9 -14.9 18.1 -18.1 21.5 -21.5 ` 25.2 -25,2 29.3 -29.3 33.6 -316 43.2 -43.2 -0 2 10 13.3 -17.0 16.5 -21.0 19.9 -25.5 23.7 -30.3 27.8 =35.6 . 32.3 -41.2 37.0 -47.3 47.6 -60.8 rr 2 20 13.0 -16:3 ; 16.0 -20.1 •19,4_ -24.3 ' 23.0 -29.0 = 27.0 -34.0 31.4 -39.4 ,3610 -45.3; 46.3 -58.1 o 2 50 12.5 -15.3 4 15.4 -18.9 '18.6 -22.9'' € 22.2 -27.2 26.0 -32.0 ' 30.2 -37.1 34.6 "`-4215' 44.5 -54.6 ew 2 100 12.1 -14.6 E 14.9 -18.0 =18.1 -21.8 21.5 -25.9 25.2 -30.4 ; 29.3 -35.3 ,33.6 40.5 43.2 -52.0 c 3 10 13.3 -17.0 16.5 -21.0 19.9 -25.5 23.7 -30.3 27.8' .35.6 32.3 -41.2 37.0 -47.3 ; 47.6 -60.8 rt 3 20 13.0 -16.3 16 0 -20.1 19.4 -24.3 '; 23.0 -29.0 1 27.0 -34.0 31.4 -39.4 36.0 .45.3 46.3 -58.1 3 50 '12.5 -15.3 ,I 15.4 -18.9 ;18.6 =22.9 1 22.2 -27.2 l 26.0 -32.0 • 30.2 -37.1 34.6 -42,5; 44.5 -54.6 3 100 12.1 -14.6 14.9 -18.0 18.1 -21.8 ' 21.5 -25.9 25.2 -30.4 29.3 -35.3 '33.6 -40.5 ' 43.2 -52.0 4 10 14.6 -15.8 18.0 -19.5 21.8 -23.6 ; 25.9 -28.1 30.4 -33.0 35.3 -38.2 40.5 -43.9 52.0 -56.4 4 20 13.9 -15.1 17.2 -18.7 ;20.8 -22.6 24.7 -26.9 29.0 -31.6 33.7 -36.7 ,38.7 -42.1 49.6 -54.1 4 50 13.0' -14.3 1 16.1 -17.6 19.5 -21.3 ' 23.2 -25.4 i 27.2 -29.8 ; 31.6 -34.6 36.2 =39,7' 46.6 -51.0 4 100 12.4 -116 ; 15.3 -16.8 118.5 -20.4 ; 22.0 -24.2 ; 25.9 -28.4 30.0 -33.0 '34A -37.8 44.2 -48.6 3 4 500 10.9 -12.1 1 13.4 -14.9 :.16.2 -18.1 , 19.3 -21.5 22.7 -25.2 126.3 -29.3 3 30.2 -33.6 38.8 -43.2 5 10 14.6 -19.5 18.0 -24.1 21.8 -29.1 25.9 -34.7 s 30.4 -40.7 ' 35.3 -47.2 40.5 -54.2' 52.0 -69.6 5 20 13.9 -18.2 17.2 -22.5 .20.8 -27.2 ; 24.7 -32.4 29.0 -38.0 33.7 -44.0 38.7 -50.5 49.6 -64.9 5 50 '13.0 -16.5, , 16.1 -20.3 119.5 -24.6 € 23.2 -29.3 27.2. -34.3 31.6 -39.8 ,36,2 -45.7€ 46.6 -58.7 5 100 12.4 :'-15.I 15.3 -18.7 118.5 -22.6 ` 22.0 -26.9 ` 25.9 -31.6 30.0 -36.7 :34.4 -42.1 ; 44.2 -54.1 5 500 10.9 1 2.1 13.4 -14.9 116.2 -18,1 € 19.3 -21.5 '.22.7 -25.2 26.3 -29.3 3=0.2 -33.6 1 38.8 -43.2 Source: ASCE/SEI 7-05, Minimum Design Loads for Buildings and Other Structures,Chapter 6, Figure 6-3,p.42-43. Page 6 SunFrame Unirac Code-Compliant Installation Manual ®® Table 3.pnec3o(psf) Roof Overhang E(fecrm Basic Wind Speed V(mph) Wand Area Zone (sn 90 100 110 120 130 140 ' ISO 170 2 10 -21.0 -25.9 -31.4- j -37.3 -43.8 -50.8 -58.3 -74.9 i2 20 -20.6 -25.5 > -30.8= i -36.7 , " -43.0 ' £ -49.9 i -57.3 t -73.6 co to 2 50 '-20.1 -24.9 -30:1 H -35.8 i -42.0 1 -48.7 -55.9 1 -71.8 'fl 2 100 -19.8 -24.4 -29.5 -35.1 -41.2 -47.8 -54.9 -70.5 o 3 10 -34.6 -42.7 -51.6 -61.5 -72.1 .. -83.7 -96,0 -123.4 4.1 o 3 20 -27.1 -33.5 -40.5 -48.3 -56.6 -65.7 -75.4: -96.8 0 3 50 -17.3 = -21.4 -25.9 -30.8 -36.1 [ -41.9 -48.1 f ' -61.8 r� 3 100 -10.0" • -12.2 -14.8 -17.6 -20.6 € -23.9 -27.4 € -35.2 u) 2 10 -27.2 -33.5 -40.6 -48.3 '_„ -56.7 " t -65.7 -75.5 1 -96.9 w L 2 20 -27/ -33.5 -40,6 -48.3 -56.7 -65.7 -75.5. -96.9 00 2 50 -27.2 -33.5 -40.`6 -48.3 -56.7 -65.7 - -75.5 -96.9 w N 2 100 -27.2 -33.5 -40.6 -48.3 -56.7 •? -65.7 -75.5 -96.9 O 3 10 -45.7 - -56.4 -68.31 -81.2 ` -95.3 -110.6 ' -126.9 -163.0 N 3 20 -41.2 -50.9 1 -61.6` -73.3 € -86.0 _ -99.8 - -114.5 -147.1 o 3 50 -35.3 -43.6 -52.8 -62.8 -73.7 . -85.5 -98.1 -126.1 to 3 100 -30.9 -38.1 -46.1 -54.9 -64.4 1 -74.7 -85.8 -110.1 E 2 10 -24.7 -30.5 -36.9 -43.9 -51.5 ; -59.8 -68.6 ; -88.1 d 2 20 -24.0 ) -29.6 -35.8 .z" ; -42.6 -50.0 I -58.0 z .. -66.5' 1 -85.5 41 2 50 • -23.0 -28.4 -34.3 -40.8 -47.9 ' 1 -55.6 1 -63.8 -82.0 v 2 100 -22.2 -27.4 -33.2 -39.5 -46.4 € -53.8 . " -61.7 -79.3 o .' 3 10 -24.7 -30.5 -36.9 -43.9 -51.5 -59.8 -68.6 -88.1 N 3 20 -24.0 -29.6 ,. -35.8 -42.6 -50.0 3 -58.0 -66.5 -85.5 0 3 50 -23.0 -28.4 -34.3' -40.8 ;' -47.9 ; -55.6 : " =63.8 -82.0 ce 3 100 -22.2 E -27.4 -33.2 = -39.5 1 -46.4 I -53.8 1 , -61.7 -79.3 I. Source: ASCE/SEI 7-05, Minimum Design Loads for Buildings and Other Structures,Chapter 6, p.44. Step 5:Determine the Topographic Factor,Kat EXPOSURE c has open terrain with scattered obstruc- For the purposes of this code compliance document,the tions having heights generally less than 30 feet. This Topographic Factor,K5t,is taken as equal to one(1),meaning, category includes flat open country,grasslands,and all the installation is on level ground(less than 10%slope). If the water surfaces in hurricane prone regions. installation is not on level ground,please consult ASCE 7-05, EXPOSURE n has flat,unobstructed areas and water Section 6.5.7 and the local building authority to determine the surfaces outside hurricane prone regions. This catego- Topographrc Factor. ry includes smooth mud flats,salt flats,and unbroken ice. Step 6:Determine Exposure Category(B,C,D) Determine the Exposure Category by using the following Also see ASCE 7-05 pages 287-291 for further explanation and definitions for Exposure Categories. explanatory photographs,and confirm your selection with the local building authority. The ASCE/SEI 7-05*defines wind exposure categories as follows: EXPOSURE B is urban and suburban areas,wooded areas,or other terram with numerous closely spaced obstructions having the size of single family dwellings. 7 CCS ] Unirac Code-Compliant Installation Manual SunFrame Step 7:Determine adjustment factor for height and Table 4.Adjustment Factor for Roof Height& exposure category,A Exposure Category Using the Exposure Category(Step 6)and the roof height,h Exposure (ft),look up the adjustment factor for height and exposure in Mean roof Table 4. height(ft) B C D 15 1.00 1.21 1.47 Step 8:Determine the Importance Factor,I 20 I.00 1.29 1.55 25 1.00 1.35 1.61 Determine if the installation is in a hurricane prone region. 30 1.00 1.40 1.66 Look up the Importance Factor,I,Table 6,page 9,using the 35 1.05 145 1.70 occupancy category description and the hurricane prone 40 1.09 1.49 1.74 region status. 45 1.12 1.53 1.78 50 1.16 1.56 1.81 55 1.19 1.59 1.84 Step 9:Calculate the Design Wind Load,pnet(psf) 60 1.22 1.62 1.87 Multiply the Net Design Wind Pressure,pnet3o(psf)(Step 4)by Source- ASCE/SEI 7-05, Minimum Design Loads for Buildings and Other the adjustment factor for height and exposure,A(Step 7),the Structures,Chapter 6,Figure 6-3, p.44. Topographic Factor,Kzt(Step 5),and the Importance Factor,I (Step 8)using the following equation: Poet(psf)=AKztI pnet30 Pnet(Psf) =Design Wind Load(10 psf minimum) A=adjustment factor for height and exposure category(Step 7) Kzt=Topographic Factor at mean roof height,h(ft) (Step 5) I=Importance Factor(Step 8) pnet3o(psf) =net design wind pressure for Exposure B,at height =30,I=1 (Step 4) Use Table 5 below to calculate Design Wind Load. The Design Wind Load will be used in Part II to select the appropriate SunFrame Series rail,rail span and foot spacing. Table 5.Worksheet for Components and Cladding Wind Load Calculation:IBC 2006,ASCE 7-05 Variable Descnpuon Symbol Value Unit Step Reference Building_Height .._ ft Building,Least Horizontal Dimension ft Roof Pitch degrees , Exposure Category Basic,Wind_Speed . ._. _ __ _. _ __.._____. VI __._._ .... _ .._ mph _._. 1_..__ Figure j, Effective Roof Area sf 2 Roof Zone Setback Length aft 3 Table I Roof Zone Location 3 Figure 2 Net Design•Wind Pressure .__. .__ : w Pnet30 . psf_.._....._..a_.._ 4 - Table 2,3 Topographic Factor Kzt x 5 adjustment factor for height,and exposure category• A x __ _ 7 Table 4_ Importance Factor I x 8 Table 5 Total DesignWind Load Page 8 GEJ SunFrame Unirac Code-Compliant Installation Manual ®: UNORAC Table 6.Occupancy Category Importance Factor Non-Hurricane Prone Regions and Hurricane Prone Regions Hurricane Prone Re- with Basic Wind Speedy= glans with Basic Wind Category CategoryDesicripuon Building Type Examples 85-100 mph,and Alaska Speed,V>100mph I Buildings and other Agricultural facilities 0.87 0.77 structures that Certain Temporary facilities represent a low Minor Storage facilities hazard to human life in the event of failure, including,but limited to: All buildings and other II structures except those I I listed in Occupancy Categories I,Ill,and IV. Buildings and other Buildings where more than 300 people congregate structures that Schools with a capacity more than 250 1.15 1.15 III represent a substantial Day Cares with a capacity more than 150 hazard to human life in Buildings for colleges with a capacity more than 500 the event of a failure, Health Care facilities with a capacity more than 50 or more including,but not limited resident patients to: Jails and Detention Facilities Power Generating Stations Water and Sewage Treatment Facilities Telecommunication Centers Buildings that manufacutre or house hazardous materials Buildings and other Hospitals and other health care facilities having surgery or 1.15 1.15 structures designated emergency treatment IV as essential facilities, Fire,rescue,ambulance and police stations including,but not limited Designated earthquake,hurricane,or other emergency to: shelters Designated emergency preparedness communication,and operation centers Power generating stations and other public utility facilities required in an emergency Ancillary structures required for operation of Occupancy Category IV structures Aviation control towers,air traffic control centers,and emergency aircraft hangars Water storage facilities and pump structures required to maintain water pressure for fire suppression Buildings and other structures having critical national defense functions Source. IBC 2006,Table 1604.5,Occupancy Category of Buildings and other structures,p.281,ASCEISEI 7-0S, Minimum Design Loads for Buildings and Other Structures,Table 6-1, p.77 Page 9 .18UNI AC Unirac Code-Compliant Installation Manual SunFrame Part II. Procedure to Select Rail Span and Rail Type [2.1.1 Using Standard Beam Calculations, Structural Engineering Methodology The procedure to determine the Unirac SunFrame series Step 1:Determine the Total Design Load rail type and rail span uses standard beam calculations and The Total Design Load,P(psf)is determined using ASCE 7-05 structural engineering methodology. The beam calculations 2.4.1(ASD Method equations 3,5,6 and 7)by adding the Snow are based on a simply supported beam conservatively,ignoring Load',S(psf),Design Wind Load, ,Step the reductions allowed for supports of continuous beams over b'rpeer(psf)from Part I multiple supports.Please refer to Part I for more information 9 and the Dead Load(psf).Both Uplift and Downforce Wind on beam calculations,equations and assumptions. Loads calculated in Step 9 of Part 2 must be investigated. Use Table 7 to calculate the Total Design Load for the load cases. In using this document,obtaining correct results is Use the maximum absolute value of the three downforce cases dependent upon the following: and the uplift case for sizing the rail.Use the uplift case only 1.Obtain the Snow Load for your area from your local building for sizing lag bolts pull out capacities(Part II,Step 6). official. 2.Obtain the Design Wind Load,pnet. See P(psf)=1.OD+1.051(downforce case 1) Part I(Procedure to Determine the Design Wind Load)for more information on calculating the Design Wind Load. P(psf)=1.OD+1.0p net(downforce case 2) 3.Please Note:The terms rail span and footing spacing p(psf)=1.0D+0.75S1+0.75pnet(downforce case 3) are interchangeable in this document. See Figure 3 for illustrations. P(psf)=0.6D+1.0pnet (uplift) 4.To use Table 8 and Table 9 the Dead Load for your specific installation must be less than 5 psf,including modules and D=Dead Load(psf) Unirac racking systems. If the Dead Load is greater than 5 psf,see your Unirac distributor,a local structural engineer or S=Snow Load(psf) contact Unirac. pnet=Design Wind Load(psf)(Positive for downforce,negative The following procedure will guide you in selecting a Unirac for uplift) rail for a flush mount installation.It will also help determine the design loading imposed by the Unirac PV Mounting The maximum Dead Load,D(ps),is 5 psf based on market Assembly that the building structure must be capable of research and internal data. supporting. 1 Snow Load Reduction-The snow load can be reduced according to Chapter 7 of ASCE 7-05. The reduction is a function of the roof slope,Exposure Factor,Importance Factor and Thermal Factor. Figure 3.Rail span and footing spacing are interchangeable. R a i/S4ahL or foot\ \ - SA B r acing \ \e� so eNP \Ao os‘c. QeV e Cads Note:Modules must be centered symmetrically on 6r the rails(+/-2*),as shown in Figure 3.If this is 10 not the case,call Unirac for assistance. . . • • . Car.3 SunFrame Unirac Code-Compliant Installation Manual Fir UNIRAC Table 7. ASCE 7 ASD Load Combinations Description Variable DownfoiCe Cast I Dow*rce Case,L ' Downforce Case 3 upaft ,,,;• .:, Dead Load D 1.0 x . 1.0 x A' - I.0 x , CO x psf 1 , , Snow Load S 1.0 x + .. *',. , .. 0.75 x + i psf , , :, Design Wind Load Pnet • ) ,:-1.0 x * ':, -',,,,-,, 0.75-x + .1.0 x'- -1 psf Total Design Load p ....- • psf Note:Table to be filled out or attached for evaluation. Step 2:Determine the Distributed Load on the rail, Step 3:Determine Rail Span/L-Foot Spacing w(plf) Using the distributed load,w,from Part II,Step 2,look up the Determine the Distributed Load,w(pif),by multiplying the allowable spans,L,for SunFrame. module length,B(ft),by the Total Design Load,P(psf)and dividing by two.Use the maximum absolute value of the three There are two tables,L-Foot SunFrame Series Rail Span Table downforce cases and the Uplift Case. We assume each module and Double L-Foot SunFrame Series Rail Span Table. The is supported by two rails. L-Foot SunFrame Series Rail Span Table uses a single L-foot w=PB connection to the roof,wall or stand-off. The point load connection from the rail to the L-foot can be increased by using a double L-foot in the installation. Please refer to the w=Distributed Load(pounds per linear foot,plf) Part III for more installation information. B=Module Length Perpendicular to Rails(ft) P=Total Design Pressure(pounds per square foot,psf) Table 8.L-Foot SunFrame Series Rail Span Span w=Distributed Load(p4) 0 20 25 30 40 50 60 80 100 120 140 160 180 200 220 240 260 280 300 400 500 600 700 .2,„ .5F SF _SF ..„...,sF,.. SF ,LSF SF SF .1.„SE.f SF _ SF, SF ' SF Si..; , SF,,,.. iF SF TSF SF 2,5 SF SF SF _ SF SF SF SF_ SF SF SFSF SF ,SF SF SF SF_ SF SF_ 3 ,,,, ';',_,SF. 'SF SF „I'SF_ SF SE .,. SF SF SE _ SF'_ SF' „SE „,...SF SF SF,, SF _3,5 ,_,,SF SF SF ,., SF SF „„SF„,_ SF SF SF__ SF SF SF SF SF 4, ,..„SF SF SF SF „SF SF„.,„„ SF , SF SF,„<„,_SF SF SF„ SF: .- 45 SF SF SF SF SF F_ SF SF SF SF SF 5 , SF -__SF SF, SF SF SF_„_SF SF ' ,SF:,..,,, SF SF - .. — 5,5 SF SF SF SF SF sE_,. SF ST _5F_ SE, k - SF _.SF . „SF: , SF SF_ SF 7SFSF ',SF 6.5_ SF _ SF SF 0 SF_ SF SF SF SF 7 .,,,,SF SF SF SF SF.,., SF SF SF • „ - .„. -- 7.5 SF SF SF SF SF SF, SF SF 8,, , SF SF SF SE., SF SF,,,,, SF SF 85 SF: SF SF SF SF SF SF ''. _, SF SF SF „SF SF SF,,, __, _ —„ .—__ 9.5 SF SF SF SF SF SF 1,(i, SF SO 51-7 SF SF -_.: .7, :',7.7 1:._,:::: 7.,,, 77-, ip g SF SF SF SF ,11 S:F sF ,0, 0 . .:,... ' - • _ ...._ ...„___ -- 11.5 SF SF SF 12.•_ St.,._., SF .SF 12.5 SF SF 13.5 SF — . T ..,_.....__. Page 11 ifiLINIRAC Unirac Code-Compliant Installation Manual SunFrame Table 9.Double L-Foot SunFrame Series Rail Span span w=Distributed Load(p1!) (ft) 20 25 30 40 50 60 80 100 120 140 160 180 200 220 240 260 280 300 400 500 600 700 2 SF,� SF SF_,_ SF _ SF SF SF _ SF SF `SF SF SF SF SF SF _ SF — SF SF SF 'SF SF 2 5 W SF SF SF SF ,_,5f SF__ SF SF SF SF SF SF SF SF SF SF _ SF SF SF , 3 SF_ SF SF SF SF SF .._SF SF SF..,_. .SF_...,SF SF SF SF SF SF_.. SF SF SF _ ..., 3 5 , SF__ SF SF SF_. SF ,SF SF _ SF SF __SF_ SF SF, SF , SF SF ..SF_ _ SF SF 4 ,. SFSF SF ::SFJ SF,. SF SF „ SF SF_ SF SF SF SF SF _ ,SF SF SF SF _ 4.5 SF. SF SF SF SF SF SF _ SF SF SF SF SF SF SF SF SF S ,., mm SF SF SF SF_;__SF SF SF µ'SF SF SF SF SF ,_ SF SF SF _ ,_, 5.5 SF SF SF SF SF SF SF SF SF SF SF SF SF 6 SF SF SF SF SF SF SF SF SF SF SF SF '-' _ - „_, 6.5 SF SF SF SF SF SF SF SF SF SF „m.... ,_„ _____ 7 . __..SF_._SF .SF,__. .SF .,,_SF SF _p SF y_.SF SF, t,_. __ '_ — _ .._ __ _ 7.5 SF ____,SF __,SF _ SF__SF_,_ _ SF , SF _SF 8 SF SFSF SF SF SF SF SF ` 85 SF , SF SF SF , SF SF SF __ _, _ _ , 9 SF SF SF 'i-F—_,. SF SF ._ __ 9 5 SF SF SF SF SF SF 10 SF_„ SF SF SF SF 10.5 SFSF SF SF 11 --g—--Sr SF SF 11.5 SF SF SF 12 SF SF SF 12.5 SF_,._SF ,. ,_ .,:..._,_- _., ............. 13 SF ..SF _ __ ,.._.w.._ _ --__._ ...„ „, .-_. 135 SFS �a _ ,. _ , _. 14 SF Step 4: Select Rail Type Step 5:Determine the Downforce Point Load,R abs), Selecting a span affects the price of your installation. Longer at each connection based on rail span spans produce fewer wall or roof penetrations.However, When designing the Unirac Flush Mount Installation,you longer spans create higher point load forces on the building must consider the downforce Point Load,R(lbs)on the roof structure. A point load force is the amount of force structure. transferred to the building structure at each connection. The Downforce,Point Load,R(lbs),is determined by It is the installer's responsibility to verify that the building_ multiplying the Total Design Load,P(psf) (Step 1)by the Rail structure is strong enough to support the point load Span,L(ft) (Step 3)and the Module Length Perpendicular to forces. the Rails,B(ft). R(lbs) =PLB R=Point Load abs) P=Total Design Load(psf) L=Rail Span(ft) B=Module Length Perpendicular to Rails(ft) It is the installer's responsibility to verify that the building structure is strong enough to support the maximum point loads calculated according to Step 5. Page 12 SunFrame Unirac Code-Compliant Installation Manual I x Table 10.Downforce Point Load Calculation Total Design Load(downforce)(max of case I,2 or 3) P psf Step I Module length perpendicular to rails B x ft Rail Span L x ft Step 4 Downforce Point Load R lbs Step 6:Determine the Uplift Point Load,R(lbs),at each connection based on rail span You must also consider the Uplift Point Load,R(lbs),to determine the required lag bolt attachment to the roof (building)structure. Table I I.Uplift Point Load Calculation Total Design Load(uplift) P psf Step I Module length perpendicular to rails B x ft Rail Span L x ft Step 4 Uplift Point Load R lbs Table 12.Lag pull-out(withdrawal) capacities (lbs) in typical roof lumber (ASD) Use Table 12 to select a lag bolt size and embedment depth to Lag screw specifications satisfy your Uplift Point Load Force,R(lbs),requirements. Specific 5/le" shaft,* gravity per inch thread depth It is the installer's responsibility Douglas Fir,Larch 030 266 to verify that the substructure "'»' and attachment method is strong Douglas Fir,South 0.46 235 enough to support the maximum Engelmann Spruce,Lodgepole Pine point loads calculated according to (MSR 1650 f &higher) 0.46 235 Step 5 and Step 6. Hem,Fir,Redwood(close grain) 0.43 212 Hem,Fir(North) 0.46 235 Thread Southern Pine 0.55 307 depth Spruce,Pine,Fir 0.42 205 Spruce,Pine,Fir (E of 2 million psi and higher grades of MSR and MEL) 0.50 266 Sources:American Wood Council,NDS 2005,Table 1 I.2A,I I.3.2A. Notes:(I)Thread must be embedded in the side grain of a rafter or other structural member integral with the building structure. (2)Lag bolts must be located in the middle third of the structural member. (3)These values are not valid for wet service. (4)This table does not include shear capacities. If necessary,contact a local engineer to specifiy lag bolt size with regard to shear forces. (5)Install lag bolts with head and washer flush to surface(no gap).Do not over-torque. (6)Withdrawal design values for lag screw connections shall be multiplied by applicable adjustment factors if necessary.See Table 10 3.1 in the American Wood Council NDS for Wood Construction. p.ge *Use flat washers with lag screws. 13 Unirac Code-Compliant Installation Manual SunFrame Part III. Installing SunFrame The Unirac Code-Compliant Installation Instructions supports applications for building permits for photovoltaic arrays using Unirac PV module mounting systems. This manual, SunFrame Rail Planning and Assembly, governs installations using the SunFrame systems. [3.1.] SunFrame® rail components s.. _ 0 6 e ® Figure 4.SunFrame components. S-4-7---;;?:, 0 t i ` 0 li 9 lig in rA„,„,,,,-,,x 74 ,;;:, '-,,,1„,,,,T., 5‹:::'''':;4,7' : 3-;..' : 0 I Figure 5.SunFrame threaded slot rail, cross section,actual size. Page 14 CM SunFrame Unirac Code-Compliant Installation Manual ®® UNORAC 0 Rail—Supports PV modules.Use one per row of modules ®L-foot adjusting slider(optional)—Use one beneath plus one.Shipped in 8-or 16-foot lengths.6105-T5 alumi- each L-foot or aluminum two-piece standoff,except in num extrusion,anodized(clear or dark bronze)to match lowest row.6105-T5 aluminum extrusion.Sliders allow PV module frame. easier alignment of rails and better snugging of PV mod- ules between rails.Includes 3/8"x 11/d' bolt with flange ©Cap strip—Secures PV modules to rails and neatly nut for attaching L-foot or standoff shaft,and two /16' frames top of array.Lengths equals rail lengths.Cap strips x 21/z'lag bolts with flat washers for securing sliders to are sized for specific PV modules.Shipped in 8-or 16-foot rafters. lenghs.Predrilled every 8 inches.6105-T5 aluminum extrusion,anodized(clear or dark bronze)to match PV ®Flattop standoff(optional)—Use if L-foot cannot be module frame. secured directly to rafter(with tile or shake roofs,for example).Use one per L-foot. Two-piece(pictured): 0 Cap strip screw(1/4-20 x 1,Type F thread cutting)—Use 6105-T5 aluminum extrusion.Includes 3/8'x 3/a"serrated to secure each cap strip(and PV modules)to rail,one per flange bolt with EPDM washer for attaching L-foot,and predrilled hole.Use an additional end screw wherever a two 5/16"x 314 lag bolts.One-piece:Service Condition 4 predrilled hole does not fall within 4 inches of the end of (very severe)zinc-plated welded steel.Includes 3/8"x 11/d' any cap strip segment.18-8 stainless steel,clear or black bolt with lock washer for attaching L-foot.Flashings: Use to match cap strip. one per standoff.Unirac offers appropriate flashings for 0 Rail splice—Joins rail sections into single length of rail. both standoff types. It can form either a rigid or thermal expansion joint.8 inches long,predrilled.6105-T5 aluminum extrusion,an- odized(clear or dark bronze)to match PV module frame. Installer supplied materials: 0 Self-drilling screw(No.10 x 3/4")—Use 4 per rigid splice Lag screw for L-foot—Attaches L-foot or standoff to or 2 per expansion joint.Galvanized steel. rafter.Determine length and diameter based on pull-out 0 End caps—Use one to neatly close each rail end.W values in Table 3(page 8).If lag screw head is exposed to resistant black plastic. elements,use stainless steel.Under flashings,zinc plated hardware is adequate.Note:Lag screws are provided with 0 Truss-head sheet metal screw(No.8 x 5/8")—Use 2 per L-foot adjusting sliders and standoffs. end cap to secure end cap to rail.18-8 stainless steel;with black oxide coating to match end caps. Waterproof roofing sealant—Use a sealant appropriate to your roofing material. 0 L-foot—Use to secure rails either through roofing mate- rial to rafters,to L-foot adjusting sliders,or to standoffs. Clamps for standing seam metal roof—See"Frequently 6105-T5 aluminum extrusion,anodized(clear or dark Asked Questions... (p.16). bronze)to match PV module frame.Double L-foot is also available. OL-foot bolt(3/8"x 11/d')—Use one per L-foot to secure rail to L-foot.304 stainless steel. 0 Flange nut(3/8")—Use one per L-foot bolt.304 stainless steel.Required torque:30 to 35 foot-pounds. i Stainless steel hardware can seize up,a process called galling. To significantly reduce its likelihood,(1)apply lubricant to bolts,preferably Lan anti-seize lubricant,available at auto parts stores,(2)shade hardware prior to installation, and(3)avoid spinning on nuts at high speed. See Installation Supplement 910,Galling and Its Prevention,at www.unirac.com. Pug. 15 EFUNIRAC Unirac Code-Compliant Installation Manual SunFrame Installing the array Safe,efficient SunFrame installation involves three principal tasks: A. Laying out the installation area and planning for material conservation. B. Installing footings and rails,beginning with the lowest row and moving up the roof. C. Placing modules and cap strips,beginning with the highest row and moving down the roof. The following illustrated steps describe the procedure in detail.Before beginning,please note these important considerations. Footings must be lagged into structural members.Never attach them to the decking alone,which leaves both the array and roof susceptible to severe damage. AFor array widths or lengths greater than 45 feet,see instruction manual 908.1 concerning thermal expansion issues. 1'/2-at each end of array A Sample layout,illustrated in Figure 4 Assumptions:12 module's(60"x 36'), A p, arranged in 3 rows of 4 modules I `° Roof Array width =144'(36'module width x 4 modules per row) ; peak Array length=180"(60'module length x 3 rows) +3"(11/2"end rail width x 2 rails) 3/4"space between module rows +11/2'(34'between-module rail width x 2 rails) =1841/2" 1.Laying out the installation area Array ` length Module Rails Always install SunFrame rails perpendicular to rafters.(These length(see - instructions assume typical rafters that run from the gutter sja" caption) -. to the peak of the roof.If this is not the case,contact Unirac.) Rails are typically mounted horizontally(parallel to the lower -4— edge edge of the roof),and must be mounted within 10 degrees of t "" horizontal. -�. Module .F-- Leave adequate room to move safely around the array during width installation.During module installation,you will need to slide - one module in each row about a foot beyond the end of the 1'/2 ;s`°: a, rails on one side.Using the number of rows and the number of modules per row in your installation,determine the size of your array area following Figure 6. I fa t Array width 10-1 (module width times modules per row) Figure 6.Installation area layout.Note:Module length is not neces- sarily measured from the edges of the frame.Some frames have lips. Others are assembled with pan-head screws.All such features must be included in module length. F Ke 16 GO SunFrame Unirac Code-Compliant Installation Manual C® UM 2.Installing the lowest row of L-feet and rail I, ,.a In the lowest row,it is not necessary to use L-foot adjusting - .�;' ,��°i -§_ sliders,even if you plan to use them in subsequent rows.Install ,ll '4/ ,�� �- L-feet directly onto low profile roofing material such as asphalt .• ��`�' ,�;7' X40' ' shingles or sheet metal.(For high profile roofs,such as tile ,% ,�g' ,,��r or shake,use optional standoffs with flashing to raise L-feet. - ,f�' ,4, ,4'44,— L-feet must be flush with or above the highest point of the roof -�' ` ,off' r $1 ,q�"` 1 surface.) ,s, f, of , e 47 i L-feet can be placed with the double slotted side against the ,�`-0' , .'' F,;� roof surface(as in Fig.7)or with the single slotted side against %` " 4e ,poi' the roof(which increases air circulation beneath modules). ,,obi ,poi , Module-to-roof dimensions are listed on page 15 for both ar- /. ,• - "I rangements. f'�` L feet i If you are using L-foot adjusting sliders,you must use / Ak / the short side of the the L-foot against the roof in the Lag i„ ' / / 2/ _first row.See Figure 9 below. screw �. // If you are using both L-foot .f oot adjusting sliders and standoffs, / Always lag into slot see the upper box on page 11. Mk' f nearest the bend #2' in the L-foot kt Install the first row of L-feet at the lower edge of the instal- 2%" ,/ lation area(Fig.8).Ensure feet are aligned by using a chalk / /i / line.(A SunFrame rail can also be used as a straight edge.) Lower edge of Position the L-feet with respect to the lower edge of the roof as / / / ' installation area illustrated in Figures 7 and 8. Figure 7.Placement of first L-foot row. Drill a pilot hole through roof into the center of the rafter at each L-foot lag screw hole location.Apply weatherproof sealant into the hole and onto shafts of the r lag screws.Seal the underside of the L-feet with a suitable weatherproof sealant. Roof peak Fasten the L-feet to the roof with the lag screws. If the double slotted sides of the L-feet are against 'c., c.,- ;s' - the roof,lag through the slot nearest the bend in the L-foot(Figs. 7 and 8). ,'' -0 . -_ ----- _.-__- -_. Cut the rails to your �9 Utility slot for No. 10 screw array width,being sure •. ,r. ,��r �, " - to keep rail slots free ,e>°'" ="1 x, '-'4A.. _�: of roofing grit or other „" z? s"." ' Utility slot for 1�a' 3 debris.If your instal- Utility bolt Slot for la" lation requires splices, Figure 8.L-Foot footing bolt assemble them prior to orientation. ,\. attaching L feet(see"Footing and splicing require ''' ' ° �`''' 7`,:-!,,i,1. % • € ments,"p.11,and"Material planning for rails and ;'---'- cap strips,"p.13).Slide the Sia-inch mounting >, , ) bolts into the footing slots. If more than one splice ";, '''-' , , is used on a rail,slide L foot bolt(s)into the footing slot(s)of the interior rail segment(s)before splicing. --;<-7.' ”-- Loosely attach the rails to the L-feet with the -' :- flange nuts.Ensure that rails are oriented with Y s: ; -,'- „, f,, ,, respect to the L-feet as shown in Figure 9.Align the ,k `'' �^y�; ,,,` �- e�° f�w ; ;� - ,, � ends of the rail to the edge of the installation area. - ', 4 ,,_ Ensure that the rail is straight and parallel to the "� edge of the roof.Then tighten the lag screws. ‹^;.* •;" Roof peak W, i Figure 9.L-foot orientation in conjunction with ;r :. N - ! L foot adjusting sliders.The sliders include two utility slots to secure module wiring,combiner . boxes,and other system components. Page 17 :12U N1RAC Unirac Code-Compliant Installation Manual SunFrame Using standoffs with L-foot adjusting sliders Two-piece aluminum standoffs may be used with footing of each standoff to the slider using the slider's 3/s-inch hex- sliders,although flashings may not be available to cover the head bolt.Note that L-feet are positioned long side up on the entire length of the slider.Use the bases of the standoffs lowest rows and with long side down in subsequent rows— only in the lowest row.In subsequent rows,attach the shaft in the same manner as an installation with no standoffs. With standoffs of equal length,orient L-foot to compensate for If the standoff supporting the lowest rail is 1 inch taller than height difference. the standoffs on the footing sliders,place both L-feet in the same orientation—either both long side up or both short side up. 1<-8 >I< A 1 \\. L-foot This example assumes a rail seven times the length of the shaded areas.If more than one splice is used,be sure the footing spacing(A).A splice maybe located in any of the combination does not violate Requirements 5,6,or 7. Footing and splicing requirements The following criteria are required for sound installations. 3. Do not locate a splice in the center third of the span While short sections of rail are structurally permissible,they between two adjacent feet. can usually be avoided by effective planning,which also pro- 4. In a spliced length of rail,all end sections must be sup- motes superior aesthetics.See"Material planning for rails ported by no less than two L-feet. and cap strips"(p.13). 5. All interior rail sections must be supported by no less The installer is solely responsible for ensuring that the roof and than one L-foot. its structural members can support the array and its live loads. For rail lengths exceeding 48 feet thermal expansionjoinrs 6. Interior rail sections supported by only one L-foot must maybe necessary.Please contact Unirac. be adjacent,on at least one side,to a rail section sup- ported by no less than two L-feet. 1. Footing spacing along the rail(A in illustration above) Rail sections longer than half the footing spacing is determined by wind loading(see pp.5-8,especially re- step 4).Foot spacing must never exceed 48 inches. quire no fewer than two L-feet. 2. Overhang(B)must be no more than half the length of ! /Rafters the maximum footing spacing(A).For example,if Span ;A/ A is 32 inches,Overhang B should not exceed 16 inches. 1 Stringer I-- ,r- _ [t , . j---.� Rail j 'sw.,9;'> �'' Modules should always be ll supported byrails.In other words modules 1 `•',,.:�: - h a °' should never overhang rails.This is especially critical when supporting the 1 4a, ^i ;, short side of a non-rectangular module.When a rail supports a pair of non- .,,4 ' ,-" z *43 rectangular modules by themselves(right),it must be supported by at least •04`;'" "' - ; '' °•f, two L-feet.The rail should be at least 14 and no more than 24 inches long, «-`: s, ' which will likely require a stringer between rafters to ensure proper footings. Non-rectangular modules t.Ke 18 SunFrame Unirac Code-Compliant Installation Manual 3.Laying out and installing the next row of L-feet With L-feet only:Position the second row of L-feet in accor- • t. S / dance with Figure 10°Ensure that you measure between the \ ' ' ` lower bolt hole centers of each row of L-feet.Install the second - '`• z ', • Module length+31<" / row of L-feet in the same manner and orientation as the first '; ' " (hole to hole) ,�/ '' / . �. �:., � ''mss "� row,but leave the lag screws a half turn loose.Be aware of the / w ," / set-up time of your sealant;the L-feet will not be fully tight- ,/ F 4, ened until Step.4. °' „ - ` "t. ' - With L-foot adjusting sliders:Use a chalk line to mark the '' ✓'` position of the slider center holes of the next row.The illustra- y- ' tion below provides spacing guidelines.The length of the .-__._ r module(A in Fig.11)includes any protrusions,such as lips or Figure 10.L-foot separation.See the note on module length in the pan-head screws in its frame. caption of Figure 4(p.9). Attach and seal L-foot adjusting slider:Install lower lag first, footing bolt next,and upper lag last.Attach an L-foot with its short side up to each slider. Roof peak J� A=module length A —Align slider A center hole to chalk line Lowest row of L-feet r ��`\Align slider (no footing sliders) \.4.________— A-3 1/4" center hole to chalk line , -------------'\4______------ A+3/4" A+1 3/16 A+2 /a°n Figure 11.If you are using L foot adjusting sliders,this spacing between rows places L-feet at the center of their adjustment range. 4.Installing the second rail ',%-:A,,, ,,;;-'t.,-'1:',,, " ' '' g v; °, With L-feet only(Fig.12):Install and align the second rail ;-i ' 4a ,. " snu in the same manner and orientation as the first rail.After rail ° ', n: -°„;,;.,4:0,k,', •, , .`z ,;;.P"- fly. alignment,tighten the rail mounting bolts to between 30 and ,,' ``'-' ,, "` n..; _ 35 foot-pounds. = 'Module' H y" , Lay one module in place at one end of the rails,and snug a,� " "w '° ,, y the upper rail(Fig.12)toward the lower rail,leaving no gap ",'",a'''-'1,:5",4,,,,,,, m ,$ ,:°T' between the ends of the modules and either rail (If pan-head .r t. " ‘‘.;:,.-,t,-,)--;-;.-' ' °•*, ."`'• .. •i screw heads represent the true end of the modules,be sure �; z >zz, 1 .4. .G.a9'sae+i the screw heads touch the rails on both ends.)Tighten the lag ''.FI''.q ` hiilf turf,lot se" screw on that end.Slide the module down the rails,snugging '-''.i;::',.:. ;(tiht �- , •f $ R,;-, 4,„.:,,g1 the rails and tightening the remaininglagscrews asyou o. ° "° -'�:: . ° g g g3 " With L-foot adjusting sliders:Install rails on first and second rows of L-feet.Verify spacing by placing a module onto the Figure 12.Position and secure top rail. rails at several points along the row.Adjust L-foot positions as needed. 5.Installing remaining L-feet and rails • All rails are fitted and aligned. • All Install the L-feet and the rails for the remaining rows,follow footing bolts and lag screws are secure. ing Steps 3 and 4.You may use the same module to space all • The module used for fitting is resting(but not se- the rows.When complete,confirm that: cured)in the highest row. Yale 19 Unirac Code-Compliant Installation Manual SunFrame Material planning for rails and cap strips Preplanning material use for your particular array can prevent assemblies and cap strip assemblies need to be cut and structural or aesthetic problems,particularly those caused by spliced from 192-inch sections of rail and cap strip.The very short lengths of rail or cap strip.This example illustrates example illustrates one means of doing so,without violating one approach. structural requirements or aesthetic goals. Structural requirements for rails are detailed in"Footing Rail segments come from five 192-inch lengths,lettered A and splicing requirements"(p.11).Structurally,cap strips thru E.Rail A,for example,is cut into two 96-inch segments, require: with one segment spliced into each of the first two rails. • A screw in every prepunched hole(which occur Similarly,five 192-inch cap strips are designated V through every 8 inches,beginning 4 inches from the ends of Z. the rails). All cap strip segments are cut at the midpoint between • One screw 4 inches or less from the each end prepunched screw holes.For each rail,start with the cap of every rail segment.Wherever there is no strip segment that crosses the array center line,and position prepunched hole within 4 inches of an end of a over the center line so that the appropriate holes are spaced segment,drill a 1/4-inch hole 2 inches from the end equally on either side. of the segment and install a cap strip screw.(In Position each cap strip onto its rail and mark its trim point. most cases,you can avoid this situation with good Remove and trim before final mounting. material planning.) Preliminary footing and splice positions must be Structural requirements always take precedence,but usually checked against structural requirements in"Footing good planning can also achieve both material conservation and splicing requirements"(p.11).In this example, and superior aesthetics.This example conserves material the center of the array is offset 2 inches from the center and achieves two specific aesthetic goals: rafter.This prevents rail splices BD(3rd rail)and CE • Cap strip screws must align across the rails. (4th rail)from falling too close to the center of the spans between footings(Requirement 3,p.11).Because foot- • End screws must be equidistant from both sides of ings are not visible from ground level,there is negligible the array. aesthetic loss. The example assumes an array of three rows,each holding five modules 41 inches wide.Thus,four 205-inch rail Array center line Is. I I I II I I I I I I 14 - Trim line(array edge) i I Trim line (array edge),-1—o-) 1 I) I )I 1'I . I • • *V 112" 11 i i i X 96" • y • 1st cap strip I 11 I it E 3 C 83" i ' I E 122" ;I 4th rail , 9 I (I ' • ; •W 112" ' ' X 96" ; 2nd cap strip I I B 83" s 1 D 122' ,, 3rd rail I � " I is i1 i3 " ' . 3 .V 80" • .: .•' • . ,� Y 128" 3rd cap strip 1 A 96" ' ;` ', ,, 1t C 109" , 2nd rail ,I 1 s..°- - ," 1 ,1 a 1- ` { E1 6 I �'.Z�i'�-'� L ' I I • i • • •W 80" • • 1 • • .;;.,_,,:;' •F• .I I . • • • . • I Z 128" _ • • ,€1 • 4th cap strip 4t ', II A 96" ; 11 11 B 109" ; 1st rail 'l I )) '1 1 II ! I, I III II I Usable remainder:D,70";E,70";Y,64";Z,64" Page 20 • tie SunFrame Unirac Code-Compliant Installation Manual Ir UM AC 6.Securing the first module .„ Gather sufficient lengths of cap strip ---Cap strip screws -*.,, • to cover the length of the first rail.For - maximum visual appeal and material ' -- - \----7c--- --,---"- =�'"'4. conservation see"Material planning for t - \ ' ,. —.-- - "' Permissaale overhang: rails and cap strips"(p.13). „w _ 4e 1/3 module width , Slide the first module into final position o %"4 f : - �,, at one end of the array.Lay the remaining - - ,� . modules in the top row,leaving a gap m;; s about a foot wide between the first and second modules(Fig.13). - � � '� ; ,per' ��y��.;"+��,°s`'- �"B' T S•'F �ti�.'v. w The temporary gap allows the installer to „*q �r`�, �,.m %2„ �""* place one of his feet between modules.He - ,,,,, . �., can access the section of the cap strip he «., . Wig. ,\„� ---- needs to secure while leaning toward the xa peak of the roof.For the time being,the � ,- last module may overhang the rail by up Do not install second " to one third its width. ---44 „,..-- cap strip until lower , modules are place Attach the end of the cap strip with -\+ Steppirig gap the cap strip screws (Fig.13,inset),so Figure 13.Begin cap strip installation. that the upper end of the first module is secure. 11110101041140 The structural integrity of your array requires that cap strip screws fully engage the threaded rail. Use the cap s , strip screws supplied with your cap strips.Any substitute �` screws must be'/a-20 Type F thread cutting(18-8 stainless .Install screws'1010011111. ; •'':/.... \ steel)and the correct length.See Table 4(pg.15)to match N' Iii: x , screw length to the size cap strip in your installation. , ' Every cap strip segment must have a cap strip screw 4 4,, inches or less from each end.If the nearest predrilled ,'t ` ✓.'`IMS k---”- �,..--Stepping gap z,,; hole falls more than 4 inches from any end,drill a --~ .r-r' 1/4-inch hole 2 inches from the end and install an additional iia" ,, -400 screw. Figure 14.Position and secure modules one by one. AWherever it is necessary to make a new cap strip hole, -----'7" � drill a 1/4-inch hole before installing the cap strip screw. ` - oma 7.Installing the remaining modules in the top row � Slide the next module into final position and install the screws . ' .. ' , �r to secure it(Fig.14).For a neat installation,use cable ties to d � attach excess wiring to the rail beneath the flanges.Unirac's + 4 ' „21.... "A"'',� � , ' 4 *~ cable ties can be attached to the SunFrame rail by drilling a Slide c+nd s 1/4-inch hole in the rail and pushing the end of the tie into the ^K one by i n - hole. � �` , .�., •Secured. IL° ` ,. Continue the process until all modules in the top row are in ''1St trod �,, WI"- final place and secured from the top.When complete,every , ff , " Stepping gap,.. prepunched hole in the cap strip will be secured by a screw, LA ; , .�_,,, , .....4.----,,. ------ and --and the top end of the first row of modules will be secure. Figure 15.As modules slide into place,the stepping gap shifts, 8.Installing the remaining modules row by row always allowing access to the section of cap strip being secured. Repeat Steps 6 and 7 for the remaining rows(Fig.15).Each subsequent cap strip will secure the tops to the modules being installed and the bottoms of the modules in the row above. Place the final cap strip in the lowest rail,securing the bottom of the lowest module row. Page 21 :FUN!RAC Unirac Code-Compliant Installation Manual SunFrame .4'1"" 9.Installing the end caps Attach the end caps to the ends of the rails by securing with the truss head sheet metal screws provided(Fig.16). r r Figure 16.End cap installation. Table 4:PV module,cap strip,and cap strip screw compatibility To ensure code compliance and a structurally sound array,cap strip sizes and cap strip screw lengths must be compatible with the PV modules in your installation. All cap strip screws must be%a-20 Type F thread cutting(18-8 stainless steel). Module thickness or type Cap strip Required screw inches mm cross section Cap strip size length(inches) 1.34-1.42 34-36 C '/," 1.50-1.57 38-40 1.77-1.85 45-47 F I" 1.93-2.01 49-51 E 11/4" Sharp lipped modules �� G 1., Sanyo lipped modules H 3A" Page 22 MO SunFrame Unirac Code-Compliant Installation Manual RAC Frequently asked questions about standoffs and roof variations How high above the roof is a SunFrame array? SunFrame L-feet will mount to the top of the S-5!clamps The answer depends on the orientation of your L-feet and with the Sia inch stainless steel bolt provided with the S-5! the length of your standoffs,if used.See the illustration ap See www.s-5solutions.com for different clamp models and propriate to your installation. details regarding installation. How can I seal the roof penetration required when When using S-5!clamps,make sure that there are enough standoffs are lagged below the roofing material? clamp/L-feet attachments to the metal roof to meet the Metal Roof Manufacturers'and MRI specifications regarding Many types and brands of flashing can be used with Sun- wind loads,etc. _- Frame.Unirac offers an Oatey®"No-Calk"flashings for its steel standoffs and Oatey®or Unirac flashings for its `! Module thickness aluminum two-piece standoffs.See our SunFrame Pro-Pak I varies Price List. r "` How do I attach SunFrame to a standing-seam metal > 1/a" �I ` g 2 /4"± 1 � * roof? j 7/8"+118-. A good solution comes from Metal Roof Innovations,Ltd. —j (MRI).They manufacture the S-5!''''clamp,designed to at- tach a wide variety of products to most standing-seam metal ; j roofs.It is an elegant solution that eliminates flashings and i 1 Module thickness penetrations altogether. . varies 4. 1 � 21/4"± is" rm:1 Module , 1, (_ z thickness 1 varies—f t i /8"± /8- jI Standoff height i/ +1 € (3",4",6",or 7" 3 s" /a_ A all±1/a") 13/4A+1/8" II �plll Yager 23 • Unirac Code-Compliant Installation Manual SunFrame 10 year limited Product Warranty, 5 year limited Finish Warranty Unirac,Inc.,warrants to the original purchaser the practices specified by AAMA 609&610-02 If within the specified Warranty periods the ("Purchaser")of product(s)that it manufactures —"Cleaning and Maintenance for Architecturally Product shall be reasonably proven to be ("Product")at the original installation site that Finished Aluminum"(www.aamanetorg)are not defective,then Unirac shall repair or replace the the Product shall be free from defects in material followed by Purchaser.This Warranty does not defective Product,or any part thereof,in Unirac's and workmanship for a period of ten(10)years, cover damage to the Product that occurs during sole discretion.Such repair or replacement shall except for the anodized finish,which finish its shipment,storage,or installation. completely satisfy and discharge all of Unirac's shall be free from visible peeling,or cracking orliability with respect to this limited Warranty. This Warranty shall be VOID if installation of chalking under normal atmospheric conditions the Product is not performed in accordance Under no circumstances shall Unirac be liable for a period of five(5)years,from the earlierfor special,indirect or consequential damages with Unirac's written installation instructions, of I)the date the installation of the Product isor if the Product has been modified,repaired, arising out of or related to use by Purchaser of completed,or 2)30 days after the purchase ofthe Product. or reworked in a manner not previously the Product by the original Purchaser("Finish authorized by Unirac IN WRITING,or if the Manufacturers of related items,such as PV Warranty"). Product is installed in an environment for which modules and flashings,may provide written The Finish Warranty does not apply to any it was not designed Unirac shall not be liable warranties of their own.Unirac's limited foreign residue deposited on the finish.All for consequential,contingent or incidental Warranty covers only its Product,and not any installations in corrosive atmospheric conditions damages arising out of the use of the Product by related items are excluded The Finish Warranty is VOID if Purchaser under any circumstances. uN I 1411 Broadway Boulevard NE Pb �� Albuquerque NM 87102-1545 USA 24 ,- - 2:(I fi bii iq r 1p ,:...1n,,,(1-9 q '1 - 1 -F „ , %';{f €€€€` sr` jb -µ -SMA 50001 -0'2,f,-., id!!i'vt { u :1-6, 00i ,-ice;.,, r v 0C, 1 tl.,'•6 y _ .__ x :r 1y �ti:m, x.<" :-- m ry roe • �•e' kttik > _' , "gal• ""'°1 .�- � . ' - - 4,,,::� ,,,-,:<\•` A •. €was.:- „ 4;• °,,. `4, . :M '°ale ! �`"mo ,„ ,,. -;a tee{ .044' = < < .{. 'in • $ .< '''' '' •:" 'k_ 4° :" it 3a,•'a„`a V , .,,° , THE ONLY ''• zy- *. ,•-•1•°'_ `;, k . - i + ,Y `° ' ,. -a�Via' _' -"•& SECURE E POWER,SUPPLY g. �. Alk r_ n •m.° � "' A- 1 ,, < ,. °,rya }> ,, -0, , Ar , ,. �.� � .. .. -'• s mss ". . r ° , =�..?K �,. '„1�i >� . •,.xs;«wk= ' Certified '1 Innovative ` Powerful Flexible •UL 1741 and 1699B compliant , •Secure Power Supply provides l •97.6%maximum efficiency •Two MPP trackers provide •Integrated AFCI meets the require- daytime power during grid outages ` •Wide input voltage range numerous design options - ments of NEC 201 1 690.1 1 ' •Shade management with OptrTrac. •Extended operating Global Peak MPP tracking temperature range SUNNY BOY 3000TL-US / 38001L-US /400011-US / 500011-US / 60001L-US / 700011-US / 7700TL-US Setting new heights in residential inverter performance The Sunny Boy 3000TL-US/3800TL-US/4000TL-US/5000TL-US/6000TL-US/7000TL-US/7700TL-US represents the next step in performance for UL certified inverters.Its transformerless design means high efficiency and reduced weight Maximum power production is derived from wide input voltage and operating temperature ranges. Multiple MPP trackers and OptiTracTM Global Peak mitigate the effect of shade and allow for installation at challenging sites.The unique Secure Power '''+-v9 0.3- Supply feature provides daytime power in the event of a grid outage. High performance, flexible design and innovative * M * features make the Sunny Boy IL-US series the first choice among solar professionals. o SMA giyb 0 IMPO 1 } ____. Sunny Boy 3000TL-US Sunny Boy 3800TL-US Sunny Boy 4000TL-US Technical data •• , 208 V AC 240 V AC 208 V AC , 240 V AC ' 208 V AC 240 V AC Input(DC) 'Max usable DC power*cos y=1) - ` ._ 3200 W 4200 W . W - Max DC voltage600 V 600 V 600 V .Rated MPPT voltage range _ 175-480 V- 175-480 V 175-480 V MPPT operating voltage range 125-500 V 125-500 V • 125-500 V Min DC voltage/start voltage ' 125V/150V ' 125 V/i 50 V - 12-5-V/150 V Max.operating input current/per MPP tracker18 A/15 A ' 24 A/15 A_. _- 24A/15 A, E _Number of MPP trackers/stnngs per MPP tracker 2/2 ___ Output(AC) ' ._ AC nominal power - - 3000 W 3330 W 3840 W , 4000 W_ _ Max AC apparent power__..- 3000 VA ` _3330 VA u 3840 VA _ ' _4000 V_A_ Nominal AC voltage/adjustable 20,8V/• 246V/0- ' 208V/• 240V/_. 208 V/• 246V/• _a , AC voltage range_ v 183-229 V 211 -264 V ! 183-229 V 211 -264 V 183-229 V 211 -264 V„ AC grid frequency;range _ 60 Hz/59.3-b0 5 Hz60- Max. Hz J 59.3--60.5 Hz 60 Hz/59.3-60.5 Hz output Current _ 15 A __. 16 A_ 20 A Power factor(cos p) 1 1 Output phases/line connections 1/2_ 1/2 1 J 2 Harmonics _ __ _ Efficiency _Max.efficiency _, __ _ _ 97.2%'_ _ 97.6% --W 97-2-%__ _ _ 7.5% _ 97.2%- 7.5% ' 9 9 CEC efficiency _ - 96.5% 96 5% 96.5%_. , 7.0%- _ 96.5% 7.0% Protection devices + DC disconnection device , -,pC reverse-polority-protection Ground fault momtonng/Gr d monitoring _ }./• __ .. AC short circuit protection • All-pole sensitive residual current monitoring unit - • '—Arc fault circuit interrupter(AFCI)compliant to UL 16998 s - i Protection class/overvaltage category , 1/IV General data Dimensions(W/H/D)in mm(in) i 490/519/185 (193/2Q5/7.3) DC'Disconnect dimensions(W/1-1/D)in mm(in) _ 187/29'7/190_(7 4/1-1.7/7.5)_ . _ , Packing dimensions(W/H/D)in mm(in) Y _ -_ _- 617/597//266 (24 3,/23.5/1-0,5) .DC Disconnect packing dimensions(W/H/-D)-in mm(in) . - s _ -_ 370/240/280 (146/9.4/11.0) - ' - Weight/DC Disconnect weight 24 kg (53 lb)/3 5 kg (8 Ib) - Packmg,weight/DC Disconnect,packmg weight 27 kg (b0 Ib)/3.5 kg (B Ib)_ ,__ - Operating temperature range -40°C . +60°C (-40°F - +140°F) Norse emission(typical) 5 25 dB(A) <25 dB(A} <25 dB(A) ' Internal consumption at night <1 W <1 W , <1 W Topology - Transformerless Transformerless Transformerless CoolingConvection Convection Convection Electronics protection rating , NEMA 3R , NEMA 3R - , NEMA 3R Features . _ _ _ -- -,- Secure Power Supply a S • Display graphic • • • Interfaces-RS485/Speedwire/Webconnect ' 0/00/0_ -_ - o/0 _ Warranty.10/15/20 years •/a/U ....11170/P _ _ ._ 4.1/0/0 Certificates and permits(more available on request) UL 1741,UL 1998,UL 16998,IEEE1547,FCC Part 15(Class-A&B),CAN/CSA C22.2 107.1-1 , , NOTE:US inverters ship with gray lids _ Type designation _ _ SB 3000TUUS-22 , _ __SB 3800Th-US-22 _ i Si 4000T411S-22 i y-, t- P Efficiency curve SUNNY BOY 500011-US-22 240Vac Accessories ••- .. ... „ Speedwir, e connec interface ..-.. 96_ - . . . interface ,° DM-485U-05-10 il: WDM JS-10 94- _ - i — -- r \ ami i __ - 98, •�-�, Fon tit for SB 3000/3800/ a_ 90- 1_ _-�- - -- •• •- 'E 4000/5000TL-U3.22 a+ .,+' EANKIT02-10 i -••• Eta IV,.,=175 VI 96}— — -- -- — - F"'" . .. , — Eta IV,,,=400 VI I vs 4(ta , 86' „_,-,-,--.,„ - Eta IV,.,=480 V)°_ V.,IVl - ' 00 02 04 06 08 10 •Standard feature 0 Optional feature -Not available Output power/Rated power Data at nominal conditions Sunny Boy 5000TL-US Sunny Boy 600071-US Sunny Boy 7000TL-US Sunny Boy 770011-US 208VAC 240 VAC 208VAC 240VAC 208VAC 240VAC 208VAC , 240VAC , 5300 W 6300 W 7300 W 8000 W 600 V 600 V 600 V - - 600 V - 175-480V 210-480V 245-480V 270-480V , 125-500 V 125-500 V 125-500 V 125-500 V ' 125V/150V 125V/,150V 125V/150V 125V/150V 30A/15A 30A/15A 30A/18A 30A/18A 2/2 ' 4550 W 5000 W 5200 W . _ 6000 W 6000 W 7000 W 6650 W - 7680 W 4550 VA , 5000 VA 5200 VA 6000 VA_ _ 6000 VA _ 7000 VA - 6650 VA ' _ 7680 VA 208V/• 240V/• _ 208 V/• • 240 V/• 208V/• 240 V/• 208V/•- 240V/• -183_-229V 211 -264V 183-229V 211 -264V 183-229V 211 -264V 183-229V 211 -264V ' 60 Hz/59.3:60.5 Hz 60 Hz/59.3-60.5 Hz_ _ 60 Hz/59.3-60.5 Hz - _ 60 Hz/59.3,-,60.5 Hz ' 22A 25A 292A 32A 1 1 1 - 1 _ 1/2 1/2 1/2 -1/2 - <4% <4% <4% <4% ' 97.2% •__ ,97.6% 97.0% _97.4%,_ _ _96.8% 96.8% - 96.8% 97,3%- -96.5% 97 0% 96.5% 97.0% 96.5% 96.5% 96 5% _ ' 96.5% 0/0 ..... • • I/tV - 490/519/185 (193/2.05/73) 187/297/190 (74/11.7/75) - 617/597/266 (243/23.5/105) 370/240/280 (146/9.4/110) - 24 kg (53 Ib)/3.5 kg (8 Ib) _ .._ 27 kg (60 Ib)/-3 5 kg_(8 Ib) -40°C . +60°C (-40°F...+140°F) • <29 dB(A) <29 dB(A) - <29 dB(A) • <29 dB(A) <1 W . , <1 W <1 W <1 W -, Transformerless Transformerless Transformerless Transformerless , Convection ' Fan Fan Fan - NEMA3R NEMA3R NEMA3R NEMA3R , • • • • to O/0 - -- 0/0 - 0/0 _ _ - 0/0 _ , •10/0 _. ._!/o/o - •/o/o •/o/a UL 1741,UL 1998,UL 16996,IEEE 1547,FCC Part 15(Class A&B),CAN/CSA C22.2 107.1-1 - - SB 5000TL•US-22 - SB 6000TL-US-22 ' SB 7000TE-US-22 SB 7700T1-US-22 . ..f - i ' ';t �9^ i dike' 1, ` More efficient Shade management Easier x'4;4. €; ' ti ft, f , • ..„-AP •e ; ,. U � s� *�' . Secure Power Supply Broad temperature range Flexible communications A NEW GENERATION OF INNOVATION THE SUNNY BOY IL-US RESIDENTIAL SERIES HAS YET AGAIN REDEFINED THE CATEGORY. Transformerless design in all types of climates and for longer periods of Leading monitoring time than with most traditional string inverters and control solutions The Sunny Boy 3000TL-US / 3800TL-US _ / 4000TL-US / 5000TL-US / 6000TL-US / Secure Power Supply The new TL-US residential line features more .z"-- 7000TL-US/7700TL-US are transformerless than high performance and a large graphic inverters, which means owners and installers One of many unique features of the TL-US display. The monitoring and control options benefit from high efficiency and lower weight. residential series is its innovative Secure provide users with an outstanding degree of A wide input voltage range also means the Power Supply. With most grid-tied inverters, flexibility. Multiple communication options !I. inverters will produce high amounts of power when the grid goes down, so does the solar- allow for a highly controllable inverter under a number of conditions powered home SMA's solution provides and one that can be monitored on Sunny daytime energy to a dedicated power outlet Portal from anywhere on the planet via an `i Additionally, transformerless inverters have during prolonged grid outages, providing Internet connection. Whether communicating s o been shown to be among the safest string homeowners with access to power as long as through RS485, or SMA's new plug-and-play t inverters on the market.An industry first,the TL- the sun shines. WebConnect, installers can find an optimal US series has been tested to UL 1741 and UL solution to their monitoring needs. 1699B and is in compliance with the arc fault Simple installation ` requirements of NEC 2011 Wide Power Class Range ` As a transformerless inverter, the TL-US Increased energy production residential series is lighter in weight than Whether you're looking for a model to its transformer-based counterparts, making maximize a 100 A service panel or trying OptiTracTM Global Peak, SMA's shade- it easier to lift and transport A new wall to meet the needs of a larger residential PV o tolerant MPP tracking algorithm, quickly mounting plate features anti-theft security and system, the Sunny Boy TL-US with Secure adjusts to changes in solar irradiation, which makes hanging the inverter quick and easy.A Power Supply has you covered. Its wide mitigates the effects of shade and results in simplified DC wiring concept allows the DC range of power classes—from 3 to 7.7 kW— a`- higher total power output.And,with two MPP disconnect to be used as a wire raceway, offers customers the right size for virtually any =, trackers, the TL-US series can ably handle saving labor and materials. residential application.The TL-US series is not complex roofs with multiple orientations or only the smartest inverter on the planet,it's also N string lengths. The 3800TL US and 7700TL-US models allow the most flexible installers to maximize system size and energy An extended operating temperature range of production for customers with 100 A and 200 _ _ -40 °F to+140 °F ensures power is produced A service panels. - si Toll Free+1 888 4 SMA USA www.SMA-America.com SMA America, LLC