Loading...
HomeMy WebLinkAboutCity Scape Site Review 12/2015 Towns of Southold New York Telecommunications Site Review Consultants, Inc. 7050 West Palmetto Park Road,#15-652 Colocation Application Boca Raton, FL 33433 Tel:877.438.2851 Fax:877.220.4593 December 10 2015 Mr. Brian Cummings )° Planner Town Hall Annex Building 53095 Route 25wd Southold,New York 11971 RE: SMSA Limited Partnership d/b/a/Verizon Wireless "East Marion" SCTM#1000-31-3-11.31 Dear Mr. Cummings, At your request, on behalf of the Town of Southold ("Town"), CityScape Consultants, Inc. ("CityScape") in its capacity as telecommunications consultant for the County, has considered the merits of the above referenced application submitted by SMSA Limited Partnership d/b/a Verizon Wireless ("Applicant") to add equipment to an existing one hundred ten (110) foot concealed (slick stick) tower, owned by Crown Castle. The tower is located at 9245 Main Road, East Marion, see Figure 1. Support Structure&Equipment This application will allow Verizon to improve its LTE/AWS service in the immediate area. It will also alleviate capacity issues for the adjacent Verizon sites, which will provide faster and more reliable service for its customers. The application herein proposes to install three (3) multi-band panel antennas, three (3) signal diplexers and twelve (12) 7/8" coaxial cables. This equipment will all be entirely concealed within the outer shell of the structure. These modifications to the tower equipment will occur at the ninety five and a half(95' 6") foot level, Appendix, Exhibits A &B. Under the Middle Class Tax Relief and Job Creation Act of 2012 ("The Act") any personal wireless facility collocation, modification or upgrade may qualify for streamlined processing. Furthermore, under Section 6409(a) it can qualify for administrative approval if the request meets six criteria, most notably (1) it does not increase the structure height by 10% or 20 feet, whichever is greater, (2) it does not increase the structure width by 20 feet and (3) it does not require any excavation outside the existing ground compound. Section 6409(a) further states that if an application meets the criteria, the application should be approved and not denied. CityScape has determined this application complies with the Act and should be approved. Town of Southold,New York SCTM#1000-31-3-11.31 MW Le,"Ift'Now WIN Page 2 Consultants, Inc. Structural Analysis The Applicant submitted a structural analysis ("SA"), prepared by Paul J. Ford & Company, dated October 23, 2014 and based on ANSI/EIA/TIA-222-F standards. The report summary indicates that with the upgrades, the tower is still within its design limits, see Appendix, Exhibit C. Specifically, the tower with the existing and proposed equipment will have a stress rating of 83.4%while the base (foundation) rating will have a stress rating of 72.4%. It is noted that the previous SA (GPR Group, 12/13/2012) listed a much lower rating, a difference that seems to account for more than just the equipment being proposed herein. Comparison of that SA reveals that it may not have included all the appurtenances on the structure at that time. Thus, the rating would be higher, narrowing the gap between values for the two SAs. The referenced facility and tower has been designed, constructed and continues to be operated by the Tower Owner and professionals with expertise in telecommunications site design and construction. The facility has been designed to maximize the use of telecommunications facility and will have the capability to provide space for future collocation opportunities. The submitted application conforms to the requirements of Town codes and State of New York wind codes and structural integrity. Therefore, it is Cityscape's recommendation that the Town approve the application with the following condition: All feed lines shall be installed within the concealed structure and all access ports shall be concealed to prevent animal/rodent entry. I certify that to the best of my knowledge all of the information included herein is accurate at the time of this report. CityScape is only employed by local governments and has unbiased opinions. All recommendations are based on technical merits without prejudice, according to prevailing laws and codes. Respectfully submitted, v Jonathan N. Edwards, P.E. Cityscape Consultants, Inc. Town of Southold,New York SCTM#1000-31-3-11.31 Page 3 Consultants, Inc. No, a,wo DeLonne Street Atlas USAW 2009 w „< „e. r, rq V11 14 r a, r vrim c'ti^•. aGMv'l Of Y ,,,.. � e r r 7 �r Data use Su*ct to license. R ®DeLomre.DeLorme Street Atlas USA®2M. 1�VI 0 000 1200 1800 2400 3000 www-Momie.com MN(13 8-W) Data Zoom 13-3 Figure 1 — Site Location Town of Southold,New York I qlmn"mr: �a ! SCTM#1000-31-3-11.31 iia be,"Okifilfbod � Page 4 Consultants, Inc. Appendix Town of Southold,New York SCTM#1000-31-3-11.31 DNA Page 5 Consultants, Inc. EXISTING F.D.. WHIP ANTENNA ATOP POLE I 18'-0" t AGL TOP OF EXISTING WHIP ANTENNA EXISTING AT&T ANTENNAS TO REMAIN .......... 110'-0" ± AGL TOP OF EXISTING MONOPOLE EXISTING 110' HIGH RF COMPATIBLE CONCEALMENT (RFCC) POLE WITH (3) NEW VERIZON WIRELESS ANTENNAS AND (6) DIPLEXERS WITHIN 107'-0" ± AGL OF EXISTING AT&T ANTENNAS 100'-0" ± AGL TOP OF VERIZON WIRELESS ANTENNA CAVITY 99'-6" ± AGL T.O. NEW, VERIZON WIRELESS SECTOR ANTENNAS 0 LLJ < 95'-6" ± AGL U)W<ft� CLOF NEW, VERIZON WIRELESS SECTOR ANTENNAS O LLJ < _j 90'-0" ± AGL BOTTOM OF NEW VERIZON WIRELESS CAVITY OF EXISTING T-MOBILE ANTENNAS OF EXISTING METRO PCS ANTENNAS mFw 'A'RW�ON ANU:UNA P,Y P h Cfffll^$ W"'UILD LIP V'HoN I"I" tXKUPK" IIS EXISTING F.D. WHIP ANTENNA, TYP. EXISTING F.D. ANTENNA CABLES TO BE RE-ROUTED THROUGH CA, PORT ON EAST SIDE OF PORT NEW ELEVATED CABLE ICE BRIDGE FOR (12) NEW 7/8-0 a CkOF FD. WHIP ANTENNA"MOUNTS VERIZON WIRELESS ANTENNA COAX CABLES (4) NEW VERIZON WIRELESS GPS UNITS SECURED TO NEW WEATHER CANOPY ..... ...... ... NEW 6'-0" HIGH FENCE WITH (1) 4'-0" WIDE GATE ............. ..... . NEW VERIZON WIRELESS EQUIPMENT CABINETS SET ATOPAj'� NEW CONCRETE PAD WITH NEW WEATHER CANOPY ABOVE or 00 W NEW VERIZON WIRELESS 50KW DIESEL GENERATOR WITH (111 0S IIkit NIA11WH f.ANOPY SOUND ENCLOSURE ATOP NEW CONCRETE PAD A 6'-0" ± AOL TOP OF NEW CHAIN LINK FENCE 0'-0" (35' t AMSL) GRADE ................................ —-—--—-.----- ._..............._.......w__._....,_........... Exhibit A - Existing Support Structure .......... ................. llllltlli Town of Southold,New York �-;-�� SCTM#1000-31-3-11.31 - 0 � i it 010,11 i Page 6 Consultants, Inc. EXISTING RF COMPATIBLE CONCEALMENT POLE BY OTHERS •--- 100'-0"t AGL . . ... T.O. ANTENNA CAVITY '^ 99'-6"t AGL T.O. OF NEW VERIZON WIRELESS SECTOR ANTENNAS EXISTING REMOVABLE COVER FOR ANTENNAS _ -................ ................ ....__n 95'-6"t AGL OF NEW VERIZON WIRELESS -00 SECTOR ANTENNAS (3) NEW VERIZON WIRELESS ANTENNAS AND MOUNTING BRACKETS (TYP ......... 6 N DIP S SECUREDT EW LEXER 0 u EXISTING ANTENNA MOUNTING POLE (TYP.) f 90'—O"± AGL ___...., a o a ---_ V. B.O. EXISTING ANTENNA CAVITY ...........-._-.................... �� � Exhibit—B—Proposed—An tenna....Configuration Town of Southold,New York "T'°''tPM M SCTM#1000-31-3-11.31 111, k41 Jw C IA I m : Page 7 Consultants, Inc. PAUL J. FORD AND COMPANY S T R U C T U R A L E N G I N E E R S 250 East Broad Street • Suite.600 • Columbus, Ohio 43215-3700 Date: October 23,2014 Mitzi Parker Paul J.Ford and Company Crown Castle 250 East Broad St.,Suite 600 3530 Toringdon Way,Suite 300 Columbus,OH 43215 Charlotte, NC 28277 (614)221-6679 Subject: Structural Analysis Report Carrier Designation: Verizon Wireless Co-Locate Carrier Site Number: N/A Carrier Site Name: East Marion Crown Castle Designation: Crown Castle BU Number: 867111 Crown Castle Site Name: EASTMARION n Castle JDE Job Number:ber: 296560 m Crown Castle Work Order Number: 9471'31 Crown Castle Application Number: 247537Rev, 5 Engineering Firm Designation: Paul J.Ford and Company Project Number: 37514-2382.001.7805 Site Data: 9245 MAIN ROAD,EAST MARION,Suffolk County,NY Latitude 41°7'41.71",Longitude-72°20'28.71 109 Foot-Monopole Tower Dear Mitzi Parker, Paul J. Ford and Company is pleased to submit this"Structural Analysis Report" to determine the structural integrity of the above mentioned tower. This analysis has been performed In accordance with the Crown Castle Structural 'Statement of Work'and the terms of Crown Castle Purchase Order Number 719109, In accordance with application 247537,revision 5. The purpose of the analysis is to determine acceptability of the tower stress level. Based on our analysis we have determined the tower stress level for the structure and foundation, under the following load case,to be: .... .............................................................................................I.................. e . . p for h p....o .................. res ... .µ LCS: Exisbn +Proposed E ul ment Sufficient Capacity Note:See Table I and Table II for the proposed and existing/reserved loading reapeclively. The analysis has been performed in accordance with the TIAIEIA-222-F standard and 2010 New York Building Code a wind speed of 85 mph fastest mile. We at Paul J. Ford and Company appreciate the opportunity of providing our continuing professional services to you and Crown Castle. If you have any questions or need further assistance on this or any other projects please give us a call. Respectfully submitted by: Maria C. Lopez,P.E. Project Manager tnxTower Report-version 6.1.4.1 Exhibit C — Structural Analysis Summary