Loading...
HomeMy WebLinkAbout40024-Z ®�$ '4'0'ti Town of Southold 12/4/2015 P.O.Box1179 ' CO . '4' 53095 Main Rd cf., y a: s Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 37945 Date: 12/4/2015 THIS CERTIFIES that the building COMMERCIAL Location of Property: 9625 Main Bayview Rd, Southold SCTM#: 473889 Sec/Block/Lot: 88.-3-23.1 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 8/20/2015 pursuant to which Building Permit No. 40024 dated 8/20/2015 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: fire alarm and sprinkler system as applied for. The certificate is issued to Homes Anew I Ltd of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL 'ELECTRICAL CERTIFICATE NO. ' PLUMBERS CERTIFICATION DATED / 01 0lig.„4 Aut o &leri nat re g o§vF of TOWN OF SOUTHOLD ,al 'a) o`- 6e, 4®1 * BUILDING DEPARTMENT TOWN CLERK'S OFFICE , SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 40024 Date: 8/20/2015 Permission is hereby granted to: Homes Anew I Ltd 191 Sweet Hollow Rd Old Bethpage, NY 118041314 To: install a fire alarm and sprinkler system as applied for. I At premises located at: 1 9625 Main Bayview Rd SCTM # 473889 Sec/Block/Lot# 88.-3-23.1 Pursuant to application dated 8/20/2015 and approved by the Building Inspector. To expire on 2/18/2017. Fees: COMMERCIAL ADDITION/ALTERATION $250.00 CO -COMMERCIAL $50.00 Total: $300.00 / L . ding Inspec o Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings, property lines, streets, and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal (S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead. 5. Commercial building, industrial building,multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings (prior to April 9, 1957) non-conforming uses,or buildings and "pre-existing" land uses: 1. Accurate survey of property showing all property lines,streets, building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy -New dwelling$50.00,Additions to dwelling$50.00,Alterations to dwelling$50.00, Swimming pool $50.00, Accessory building$50.00,Additions to accessory building $50.00,Businesses $50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy - $.25 4. Updated Certificate of Occupancy - $50.00 5. Temporary Certificate of Occupancy -Residential$15.00, Commercial $15.00 Date. New Construction: Old or Pre-existing Building: (check one) Location of Property: 9/2. W RAllii 2. 5 LA.i?-1-D House No. Street Hamlet Owner or Owners of Property:fA-em r LY /4.&- 11,-.119ty. - �S� i>>4-2 1�i2��11p�� e -LT1 L' . Suffolk County Tax Map No 1000, Section Block Lot Subdivision Filed Map. Lot: Permit No. Date of Permit. Applicant: Health Dept. Approval: Underwriters Approval: Planning Board Approval: Request for: Temporary Certificate Final Certificate: (check one) • Fee Submitted: $ jT Applicant Signature ACJ22_1_, f SOUty�lo, ,#t a TOWN OF SOUTHOLD BUILDING 'DEPT.-- 765-1802 EPT:-765-1802 • INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLUMBING [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING / STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] IRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIO ION [ ] CAULKING REM ! - KS: !/ ' -►' Aff 4Z2 � Q C !!r%_ ,ice ► /, l" ,)(a_ W)2EK" 8(244fie V1Afae- Dk.) PftAL-S-66- 1111* /2- .�DATE 2 - /o INSPECTOR Aug 20 15 04: 46p p. 1 0 -1\I:1�1 'Mirk FRANK A. RESTITUTO EMI TET MUMARCHITECT CRABAPPLE LANE, COMMACK, NEW YORK 11725 (631) 543-5430 (631) 343-7047 FAX FRESTITUTO©AOL.COM August 19,2015 Southold Town Hall Annex Building Department 54375 Main Road PO Box 1179 Southold,New York 11971 Attn: Damon Rallis -- - - ------ Fax-631-765-9502- Re: Family Residences and Essential Enterprises,Inc 9625 Main Bayview Road Southold,New York Please be advised that the fire alarm and smoke detection system proposed for the above referenced site will be installed in strict accordance with the New York State Code and all applicable local codes. If there a • ny questions or if additional information is required,please do not hesitate to call on me. Than :• i, / / . _.....,04.0 A-3.--, ..,., ..,„ , i/e, fill :1-1:r<:3. AO ',' ' tiq,. •i % 2 -•. : .Restituto 'P. (:�'?l` .,f1`>#:i g tr Archi ect $,\ -`=�.y- —d ' s.,G ti• • FIELD S?E QN REPOItt DAA COIV ERITS . •. . - — 8 1 FOUNDAON(1ST) . . • FOUNDATION(2ND) zgzzt4 1 , ` o • 3. ROUGFI FRANCENG•& ,, . H PLUMBING •--.--= . • . . , . . • • • • • • • ti> • y IN ULATION PEA N, ' STATE ENERGY CODE . Z • • • FINAL • ' M� err+•..••-- y .. .. , F" _ v it • ,. , , 1" 2 )S' . ;aif 4, A_, i u' U 1 �'�j ,6,1- 1_{II ®� �%J -, iiii 1. J/�� `L , .--:: , t- • / i ' , • V • • • ti d TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST { BUILDING DEPARTMENT Do you have or need the following,before applymg? TOWN HALL Board of Health SOUTHOLD,NY 11971 4 sets of Building Plans TEL:(631)765-1802 Planning Board approval FAX:(631)765-9502 Survey SoutholdTown.NorthFork.net PERMIT NO.f0 02 Check Septic Form N.Y S.D E C. Trustees C O Application Flood Permit Examined ,20 Single&Separate Storm-Water Assessment Form U ( ) Contact: I/ Approved20 ::° Disapproveda/c : 0-13 ZO Expiration ,20 r 401Yldi�_ pe• or r' J h APPLICATION FOR BUILDING PERMIT !� I 714- Date4U6iA3T4 ,20 �S^ U Li AUG -6 2015 IL) INSTRUCTIONS a.This application i ST L e completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 •r. I ans aceurateplot: an to s-ale Fee according to schedule. `b.Plot plan showing Iocatic n of lot and of buildings on premises,relationship to adjoining premises or public streets or ar-eas-aacl-watema S c The work covered by this application may not be commenced before issuance of Building Permit. d.Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant.Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy f.Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date.If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize,m writing,the extension of the permit for an addition six months.Thereafter,a new permit shall be required APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk County,New York,and other applicable Laws,Ordinances or Regulations,for the construction of buildings,additions,or alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code,housing code,and re!.' ations,and to admit authorized inspectors on premises and in building for necessary inspections. ignature of ap•ican or name,if a corporation) elaly ,B iae21Y/17/7 (Mailing address of applicant) State whether applicant is owner,lessee,agent,architect,engineer,general contractor,electrician,plumber or builder t,2C �F�i c c i/©per C��!c'�ze9-? (5/94edez tee_ <4 7L'7"rg- /11.62til Name of owner of premises risme!Y ES I p csu c0 tS'S'C\/j,4-L 1;11tre4'IGI/15-1 JN[ n the tax roll or latest deed) PS A-r e,� ) If applic a corpo on,signature of duly auth offiittGv Y l cer / (Name and title of corporate officer) Builders License No. Plumbers License No. 4R"ot-r chtAJ?Y Electricians License No. Other Trade's License No.)-1Y51 aL ?fit( L 1 e. *12-000 259411 1. Location of land on which proposedwork�O be gene: 9 �47 L1 MOO House Number Street Hamlet County Tax Map No. 1000 Section ge Block 3 Lot .23•/ Subdivision Filed Map No. Lot , r 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy S I D�Y b. Intended use and occupancy 3. Nature of work(check which applicable):New Building Addition Alteration Repair Removal Demolition Other Work 7,,e6 f/�7ZI//fCL$Z.. 51, (Description) 4. Estimated Cost JO, Iy 0 0 Fee (To be paid on filing this application) 5. If dwelling,number of dwelling units Number of dwelling units on each floor If garage, number of cars 6. If business,commercial or mixed occupancy,specify nature and extent of each type of use. 7. Dimensions of existing structures,if any:Front Rear Depth Height Number of Stories Dimensions of same structure with alterations or additions: Front Rear Depth Height Number of Stories 8. Dimensions of entire new construction:Front Rear Depth Height Number of Stories 9. Size of lot:Front Rear Depth 10.Date of Purchase Name of Former Owner 11.Zone or use district in which premises are situated 12.Does proposed construction violate any zoning law,ordinance or regulation?YES NO 13.Will lot be re-graded?YES NO Will excess fill be removed from premises?YES NO 14.Names of Owner of premises /ZEE Address/9/ 1zUEE O11D Phone No. /G 4-70 — ib OP Name of Architect 7 ,-Af^1g X E S7 7i41'O Address /9 CI- sem;,:, L APhone No I 5' 3—S 3 Name of Contractor 8K /LE sc(9d22FgSion/Address ':-hone No. g / —AO o tJ/2/ Y sVtr�aas -giecrvroo0o,frst' 15 a.Is this property within 100 feet of a tidal wetland or a freshwater wetland?*YES NO k *IF YES,SOUTHOLD TOWN TRUSTEES&D.E.C.PERMITS MAY BE REQUIRED. b.Is this property within 300 feet of a tidal wetland?*YES NO *IF YES,D.E.C.PERMITS MAY BE REQUIRED. 16.Provide survey,to scale,with accurate foundation plan and distances to property lines. 17.If elevation at any point on property is at 10 feet or below,must provide topographical data on survey. 18.Are there any covenants and restrictions with respect to this property?*YES NO X *IF YES,PROVIDE A COPY. _ _ _ „; �,•, CHRISTINE VIRGINIA BLUMENAUER STATE OF NEW YORK) NotaryPublic,State of Newyork SS: . 85523 COUNTY OFSw({ttL + No.01BL62olkCo + ;: Qualified in Suffolk County ' esSepte ber03 20 l 40/.1 !M�l 1 'r 1'� ,.� ., . .is the applicant (Name of individual signing contract)abo (S)He is the me. 2.e SitPPl S S/ties..) 4- _q&L-7f/2/1`'y 0077 t41 f (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief;and that the work will be performed in the manner set forth in the application filed therewith Swo r before me this day of 1 '1/( 1,0” 20 / S Notary Public 4ignofpIican r 'kI ' i - CONTRACTOR'S MATERIAL-'8i TEST CERTIFICATE FOR ABOVE GROUND-PIPING PROCEDURE: i;, ' - an �t�mpleGon of work,inspection and tests shalt be made by the contractor's representative witnessed by an owner's representative.. the job_ . elects shall be condected do system left in service before contractor's personnel finalhr f " A certificate shall be filled out and signed by both representatives. Copies shall be prepared for approving authorities.owners and contractor. 1.us understood the owner's representative's signature in no way prejudices any claim against the contractor for faulty material,poor workmanship,or failure to cornpr r.:tn approving authounlys requirements or local ordinances. DATE a=�PERTY NAME,...c Ge 1\( /- 2ef u i 4 PROPERTY ADDRESS iJ ,",( .� . f !�` �C��7 Qlo2s MSI -Y V1 1 0)- , S0 LCt tnl t ACCEPTED BY�APPROVING AUTHORTY'( NAMES - i VIAT or ‘,01.11-1-1-0 L- ` •- 'ADDRESS i /► . rtA.. >0IA:T i cam t X1 Y I t x'71 -070-1W--; - -`INSTALLATION CONFORMS TO ACCEPTED PLANS 1fd S DNO - • - - EQUIPMENT USED IS APPROVED(IF NO,STATE DEVIATIONS BELOW) . ONO nYES ONO `HAS PERSON IN CARGE OF FIRE EQUIPMENT BEEN INSTRUCTED AS TO LOCATION OF L�� r_CONTROL VALVES AND THE CARE AND MAINTENANCE OF THIS NEWEQUIPMENT? - 4-• -- s- = • IF NO,EXPLAIN: Il�lb�?P -__$° 1:Ert'S ONO - - -- -HAS COPIES OF APPROPRIATE INSTRUCTIONS AND CARE AND MAINTENANCE CHARTS Lit - = ---;:- -BEEN LEFT ON PREMISES? : - IF NO,EXPLAIN -Lathi ik SUPPLIES BUILDINGS0 - s- _- ' 2 -6- t'E 1.741-D c.r--k-i--- _ YEAR OF ORIFICE MAKE MODEL QUANTITY lnTEMPERATUREE RATING MANUFACTURE T {do _111 II 14-Sa/ Zpc' Tz" `?d, 1'5"C° sFiltti ` - --/Ca r'FE& LOW Z4 t5 ‘1.2° ... f g 14-s° ' - PIPE CONFORMS TO A,Fj7A- 1 S a STANDARD -..__ DNO :piPiE-AbIDTfi4LIGS>FITTINGS CONFORM TO t*STA.. j; g - STANDARD �• ONC -IF NO,EXPLAIN: _ ALARM DEVICES MAXIMUM TIME TO OPERATE THROUGH TEST PIPE - TYPE MAKE MODEL MINUTES, I___ SECONDS L.ssJQc OFt-g 14 -90T'TF-e- V4 ---- I ALARM VALVE OR i FLOW INDICATOR } 1 TRIP POINT TIME WATER ALARM OPERATED TIME TO TRIP THRti WATER AIR AIR REACHED TEST TEST PIPE PRESSURE PRESSUREPROPERLY PRESSURE -'OUTLET , MIN. SEC. PSI PSI PSI MIN SEC.-_ MiN :, SEC .DRY-PIPE WITHOUT t -OPERATING`FST- Q.O.D. WITH c : Q.O.D. - - - IF NO,EXPLAIN: 'I OPERATION". OPNEWUMATICCJ�-C'_ �-�-�-='LiC I 2.'EDIASUPERVISED? DYES ONO =PIPING SUPERVISED OYES ONC O • -;DOES VALVE OPERATE FROM THE MANUAL TRIP ANDIOR REMOTE CONTROL, ❑YES ONO .: F.R.E.E. Drawing Date: 7/23/15 13:38 HYDRAULIC DESIGN INFORMATION SHEET Job Name: F.R.E.E. Location: 9625 Main Bayview Road Southold, New York, 11971 Drawing Date: Remote Area Number: 3 Contractor: BK Fire Suppresion & Security Systems Telephone: 631-273-2010 826 Suffolk Ave Brentwood, New York, 11717 Designer: RF Calculated By:SprinkCAD www.sprinkcad.com 451 N. Cannon Ave. Lansdale, PA 19446 Construction: Wood Frame Occupancy:Residential Reviewing Authorities:Villiage of Southold SYSTEM DESIGN Code:NFPA 13 Hazard:ordinary 1 System Type:WET Area of Sprinkler Oper. sq ftl Sprinkler or Nozzle Density (gpm/sq ft) 0.150 I Make: Tyco Area per Sprinkler 127 .0 sq ftl Model: TY-B Hose Allowance Inside 0 gpm 1 K-Factor: 5. 60 Hose Allowance Outside 0 gpm ► Temperature Rating: 155 CALCULATION SUMMARY 11 Flowing Outlets gpm Required: 307.8 psi Required: 64.0 @ Source WATER SUPPLY Water Flow Test Pump Data Date of Test 7-2-15 Rated Capacity 0 gpm Static Pressure 73. 0 psi Rated Pressure 0. 0 psi Residual Pres 46. 0 psi Elevation 0 At a Flow of 2173 gpm Make: Elevation 0" Model: Location: Source of Information: SCWA SYSTEM VOLUME 93 Gallons Notes : /; o) � .D ARS A A lf' _a ,o a % Hca` 1 w� r 1\ No. 1®7t a 4 O... THE SIN - F.R.E.E. Drawing Date: 7/23/15 13:38 HYDRAULIC CALCULATION DETAILS HYDRAULIC FLOW LOSS QTY DESCRIPTION LENGTH C ID gpm psi TOTALS Hydr Ref W Required at Hyd Area 3 208 13.3 psi 1 2" CPVC 90 Ell 9' 120 2. 067 208 3.8 1 Pipe 2" PVx15 BlazeMa Plastic 5' 150 2. 003 208 1.4 1 2" Thrd Back Flow Valve Wilkins " CHART LOSS 208 18 . 6 2 2" Sweatd 90 Ell 11' 120 2 . 067 208 4 . 7 1 Pipe 2" Kx20 Copper 60 ' 150 1. 959 208 18 .7 Elevation Change 8 ' 0" 3.5 Fixed Flow Flow Loss 100 gpm Hydr Ref R1 Required at Source 308 64.0 psi Water Source 73. 0 psi static, 46. 0 psi residual @ 2173 gpm 308 gpm 72.3 psi SAFETY PRESSURE 8.3 psi Available Pressure of 72.3 psi Exceeds Required Pressure of 64.0 psi This is a safety margin of 8.3 psi or 11 % of Supply Maximum Water Velocity is 12.7 fps F.R.E.E. Drawing Date: 7/23/15 13:38 Page 3 FITTING NAME TABLE ABBREV. NAME C Coupling E 90 ' Standard Elbow F 45' Elbow S Straight Flow Thru Tee T 90 ' Flow Thru Tee V Valve LEGEND HYD REF Hydraulic reference. Refer to accompanying flow diagram. K FACTOR Flow factor for open head or path where Flow (gpm) = K x -\/P Qa Flow added or subtracted Qt Total flow DIA Actual internal diameter of pipe C Hazen Williams pipe roughness factor Pf/ft Friction loss per foot of pipe PIPE Length of pipe FTNG'S Number of fittings . See table above. TOTAL Total length (PIPE + FTNG'S) Pt Total pressure (psi) at fitting Pe Pressure due to change in elevation where Pe = 0. 433 x change in elevation Pf Friction loss (psi) to fitting where Pf = 1 x 4 .52 x (Q/C) ^1. 85 / ID^4. 87 Pv Velocity pressure (psi) where Pv = 0 .001123 x Q^2/ID^4 Pn Normal pressure (psi) , where Pn = Pt - Pv NOTES: - Pressures are balanced to 0.01 psi. Pressures are listed to 0.1 psi. Addition may vary by 0.1 psi due to accumulation of round off. - Calculations conform to NFPA 13. - Velocity Pressures are not considered in these Calculations F.R.E.E. Drawing Date: 7/23/15 13:38 Page 4 NODE ELEVATION SPRINKLER PRESSURE ACTUAL MINIMUM ACTUAL NUMBER K-FACTOR FLOW FLOW DENSITY (FT) (GPM/ (PSI^ ) ) (PSI) (GPM) (GPM) (GPM/SQ. FT) 1C -2 . 00 5. 60 11. 6 19. 1 19. 1 0 . 15 2C -2. 00 5. 60 11 .7 19.2 19. 1 0 . 15 3C -2. 00 5. 60 12. 1 19.5 19. 1 0. 15 4C -2 . 00 5. 60 11.2 18 . 8 14 . 8 0 .26 5C -2 . 00 5. 60 12 . 4 19.7 14 . 8 0 .27 6C -2 . 00 5. 60 11 . 1 18 .7 14 . 8 0.26 7C -2 . 00 5. 60 12.3 19. 6 14 . 8 0.27 8C -2 . 00 5. 60 12.2 19. 6 14 . 8 0.29 9C -2 . 00 5. 60 12. 6 19. 9 14 . 8 0. 44 10 11 . 00 12 .7 10C -2. 00 5. 60 9. 1 16. 9 14 . 8 0.53 11 11 . 00 12 . 0 11C -2. 00 5. 60 9.1 16. 9 14 . 8 0.18 13 -2. 00 13. 0 14 -2. 00 12 . 8 15 -2 . 00 12 .7 16 -2. 00 12 .7 17 -2 . 00 13.0 18 -2 . 00 13.5 19 -2 . 00 13. 9 20 -2 .00 10 . 6 21 -2 .00 9.2 22 -2 .00 9. 9 23 -2 .00 15. 9 24 11.00 11 . 6 25 11. 00 11 . 0 50 11.00 8 . 0 W 11. 00 13.3 Max velocity of 12 . 66 occurs in the pipe from 20 TO 19 F.R.E.E. Drawing Date: 7/23/15 13:38 • Tyco Fire Products Page 5 HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG'S Pe Pv ******* NOTES ******* POINT Qt Pf/ft TOTAL Pf Pn PATH 1 FROM HYDRAULIC REFERENCE 11C TO W (PRIMARY PATH) 16. 88 1.049 1T 3.74 9. 1 9. 1 K = 5. 60 110 0=120 5. 00 0 . 0 0 .0 16. 88 0. 095 8 .74 0.8 9.1 Vel = 6.33 1.049 1T 2. 42 9. 9 9. 9 22 C=120 5. 00 0 .0 0. 0 16. 88 0. 095 7 . 42 0.7 9. 9 Vel = 6.33 16. 90 1. 049 1T 4 .56 10. 6 10 . 6 20 C=120 5. 00 0 . 0 0.0 See PATH 2 33.78 0.343 9. 56 3.3 10. 6 Vel = 12 . 66 88 . 68 2. 635 1E 24 . 02 13. 9 13. 9 19 C=120 1T 24 .71 0. 0 0 . 0 See PATH 6 122 . 45 0 .042 48 .73 2 . 0 13. 9 Vel = 7 .28 2 . 635 2E 14 . 08 15. 9 15. 9 23 0=120 16. 47 -5. 6 0. 0 122 .45 0. 042 30 . 55 1.3 15. 9 Vel = 7 .28 29. 12 2 . 635 lE 2 .52 11 . 6 11 . 6 24 C=120 1T 24 .71 0 . 0 0 .0 See PATH 9 151.58 0 . 062 27 .23 1 . 7 11. 6 Vel = 9. 01 W 151.58 13.3 K = 41 . 61 PATH 2 FROM HYDRAULIC REFERENCE 10C TO 20 16. 90 1 . 049 1 . 01 9. 1 9. 1 K = 5. 60 100 0=120 0 . 00 0. 0 0. 0 16. 90 0 .095 1 . 01 0.1 9. 1 Vel = 6.34 1.049 1E 7 .84 9.2 9.2 21 0=120 1T 7 . 00 0. 0 0. 0 16. 90 0 . 095 14 . 84 1. 4 9.2 Vel = 6. 34 20 16. 90 10 . 6 K = 5. 19 PATH 3 FROM HYDRAULIC REFERENCE 6C TO W UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) F.R.E.E. Drawing Date: 7/23/15 13:38 Tyco Fire Products Page 6 HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG'S Pe Pv ******* NOTES ******* POINT Qt Pf/ft TOTAL Pf Pn PATH 3 FROM HYDRAULIC REFERENCE 6C TO W CONTINUED 18 .70 1. 049 9. 84 11. 1 11. 1 K = 5. 60 6C C=120 0. 00 0. 0 0. 0 18 .70 0.115 9. 84 1. 1 11. 1 Vel = 7. 01 19. 62 1 . 610 1T 1. 88 12 . 3 12 .3 K = 5. 60 7C 0=120 8 . 00 0. 0 0 . 0 38 .32 0. 054 9. 88 0.5 12 .3 Vel = 6. 10 96.19 2 . 635 3.28 12 .8 12. 8 14 C=120 0 . 00 0. 0 0. 0 See PATH 4 134 .51 0 . 050 3.28 0 .2 12 . 8 Vel = 7. 99 -49. 17 2 . 635 1T 13. 00 13. 0 13. 0 13 C=120 16. 47 -5. 6 0. 0 See PATH 8 85.35 0 . 021 29.47 0 . 6 13. 0 Vel = 5. 07 2 . 003 2E 30. 02 8 . 0 8 . 0 50 0=150 1T 25. 93 0 . 0 0. 0 85.35 0. 054 55. 94 3. 0 8 . 0 Vel = 8 .77 -29. 12 2 . 003 1T 28 . 49 11. 0 11 . 0 25 C=150 12 . 96 0. 0 0 . 0 See PATH 9 56.22 0. 025 41 . 46 1. 0 11 . 0 Vel = 5. 78 2 . 003 1T 15. 02 12 . 0 12. 0 11 0=150 12. 96 0. 0 0 . 0 56.22 0 . 025 27. 99 0. 7 12 . 0 Vel = 5.78 2 .003 1E 2 . 48 12 .7 12 .7 10 0=150 1T 19. 45 0. 0 0. 0 56.22 0 . 025 21. 93 0 . 5 12 .7 Vel = 5.78 W 56.22 13.3 K = 15. 43 PATH 4 FROM HYDRAULIC REFERENCE 4C TO 14 18 . 77 1. 049 9. 84 11.2 11.2 K = 5. 60 4C 0=120 0. 00 0. 0 0 . 0 18 . 77 0. 116 9. 84 1. 1 11 .2 Vel = 7 . 04 UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) F.R.E.E. Drawing Date: 7/23/15 13:38 Tyco Fire Products Page 7 HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG' S Pe Pv ******* NOTES ******* POINT Qt Pf/ft TOTAL Pf Pn PATH 4 FROM HYDRAULIC REFERENCE 4C TO 14 CONTINUED 19.70 1. 610 1E 1 . 88 12 .4 12 .4 K = 5. 60 5C C=120 4 .00 0. 0 0 . 0 38 .47 0. 054 5. 88 0 .3 12 .4 Vel = 6.12 2. 635 3.75 12 .7 12 .7 16 C=120 0 . 00 0.0 0. 0 38 . 47 0 . 005 3. 75 0. 0 12 .7 Vel = 2 .29 57 .72 2 . 635 3.75 12 .7 12 .7 15 C=120 0. 00 0 . 0 0 .0 See PATH 5 96. 19 0 .027 3.75 0 .1 12 .7 Vel = 5.71 14 96. 19 12. 8 K = 26. 87 PATH 5 FROM HYDRAULIC REFERENCE 1C TO 15 19. 05 1 . 610 8 .43 11. 6 11 . 6 K = 5. 60 10 C=120 0. 00 0 . 0 0 . 0 19. 05 0.015 8 . 43 0. 1 11. 6 Vel = 3. 03 19. 15 1 . 610 8 . 43 11.7 11.7 K = 5. 60 2C C=120 0 . 00 0. 0 0. 0 38 .20 0. 053 8 . 43 0.5 11.7 Vel = 6. 08 19.52 2 . 067 1T 6.58 12. 1 12 . 1 K = 5. 60 3C C=120 10. 00 0 . 0 0 . 0 57 .72 0 . 034 16.58 0 . 6 12 . 1 Vel = 5. 57 15 57 .72 12 .7 K = 16.19 PATH 6 FROM HYDRAULIC REFERENCE 8C TO 19 19. 60 1. 049 1T 1.23 12 .2 12.2 K = 5. 60 8C C=120 5. 00 0 . 0 0 . 0 19. 60 0. 125 6.23 0 . 8 12 .2 Vel = 7 .35 UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) F.R.E.E. Drawing Date: 7/23/15 13:38 Tyco Fire Products Page 8 HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG'S Pe Pv ******* NOTES ******* POINT Qt Pf/ft TOTAL Pf Pn PATH 6 FROM HYDRAULIC REFERENCE 8C TO 19 CONTINUED 49.17 2 . 635 1E 11.23 13. 0 13. 0 17 C=120 1T 24 .71 0 . 0 0. 0 See PATH 8 68 . 76 0 . 014 35. 94 0 . 5 13. 0 Vel = 4 . 09 19. 91 2 . 635 15. 44 13.5 13.5 18 C=120 0 . 00 0. 0 0 . 0 See PATH 7 88 . 68 0. 023 15. 44 0. 4 13. 5 Vel = 5.27 19 88 . 68 13. 9 K = 23. 78 PATH 7 FROM HYDRAULIC REFERENCE 9C TO 18 19. 91 1. 049 1T 1. 97 12 . 6 12 . 6 K = 5. 60 9C C=120 5. 00 0 . 0 0. 0 19. 91 0. 129 6. 97 0 . 9 12 . 6 Vel = 7 .46 18 19. 91 13.5 K = 5. 41 PATH 8 FROM HYDRAULIC REFERENCE 13 TO 17 49. 17 2 . 635 6. 58 13. 0 13. 0 13 C=120 0. 00 0 . 0 0. 0 See PATH 3 49. 17 0. 008 6.58 0 . 1 13. 0 Vel = 2 . 92 17 49. 17 13. 0 K = 13. 62 PATH 9 FROM HYDRAULIC REFERENCE 25 TO 24 29. 12 2 . 003 3T 40 . 73 11. 0 11 . 0 25 C=150 38 . 89 0. 0 0. 0 See PATH 3 29.12 0. 007 79. 63 0. 6 11. 0 Vel = 2 . 99 UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) F.R.E.E. Drawing Date: 7/23/15 13:38 Tyco Fire Products Page 9 HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG'S Pe Pv ******* NOTES ******* POINT Qt Pf/ft TOTAL Pf Pn 24 29. 12 11. 6 K = 8 .56 UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) Job Water Required Hose Allowance F.R.E.E. Static Pres: 73.0 psi Pressure: 64.0 psi In: 0 gpm 9625 Main Bayview Road Resid. Pres: 46.0 psi Sys Flow. 308 gpm Out: 0 gpm Southold, New York, 11971 Flow: 2173 gpm Sys+Hose: 308 gpm Remote Area: 3 Date: 7-2-15 Safety Pres. 8.3 psi Loc: Hd Ely Pres. -5.6 psi 140 120 100 80 S • Supply • 60 40 20 100 150 200 250 300 350 400 450 500 Flow (gpm) 4`1.R.E.E. Drawing Date: 7/23/15 13:38 HYDRAULIC DESIGN INFORMATION SHEET Job Name: F.R.E.E. Location: 9625 Main Bayview Road Southold, New York, 11971 Drawing Date: Remote Area Number: 2 Contractor: BK Fire Suppresion & Security Systems Telephone: 631-273-2010 826 Suffolk Ave Brentwood, New York, 11717 Designer: RF Calculated By:SprinkCAD www.sprinkcad.com 451 N. Cannon Ave. Lansdale, PA 19446 Construction: Wood Frame Occupancy:Residential Reviewing Authorities:Villiage of Southold SYSTEM DESIGN Code:NFPA 13R Hazard:LIGHT System Type:WET Area of Sprinkler Oper. sq ftl Sprinkler or Nozzle Density (gpm/sq ft) RES I Make: TYCO Area per Sprinkler 256.0 sq ftl Model: LFII Hose Allowance Inside 0 gpm 1 K-Factor: 4.20 Hose Allowance Outside 0 gpm I Temperature Rating: 155 CALCULATION SUMMARY 4 Flowing Outlets gpm Required: 154.3 psi Required: 36.1 @ Source WATER SUPPLY Water Flow Test Pump Data Date of Test 7-2-15 Rated Capacity 0 gpm Static Pressure 73. 0 psi Rated Pressure 0. 0 psi Residual Pres 46. 0 psi Elevation 0 At a Flow of 2173 gpm Make: Elevation 0" Model: Location: Source of Information: SCWA SYSTEM VOLUME 93 Gallons Notes: itit 6 1i I ,j ® *, ‘,i,\/(. �a� as F.R.E.E. Drawing Date: 7/23/15 13:38 4 411 HYDRAULIC CALCULATION DETAILS HYDRAULIC FLOW LOSS QTY DESCRIPTION LENGTH C ID gpm psi TOTALS Hydr Ref W Required at Hyd Area 2 54 17.0 psi 1 2" CPVC 90 Ell 9' 120 2 . 067 54 0.3 1 Pipe 2" PVx15 BlazeMa Plastic 5' 150 2 . 003 54 0. 1 1 2" Thrd Back Flow Valve Wilkins " CHART LOSS 54 13.2 2 2" Sweatd 90 Ell 11' 120 2 .067 54 0. 4 1 Pipe 2" Kx20 Copper 60 ' 150 1. 959 54 1 . 6 Elevation Change 8 ' 0" 3. 5 Fixed Flow Flow Loss 100 gpm Hydr Ref R1 Required at Source 154 36.1 psi Water Source 73 . 0 psi static, 46. 0 psi residual @ 2173 gpm 154 gpm 72.8 psi SAFETY PRESSURE 36.7 psi Available Pressure of 72.8 psi Exceeds Required Pressure of 36.1 psi This is a safety margin of 36.7 psi or 50 % of Supply Maximum Water Velocity is 8 .7 fps !T.R.E.E. Drawing Date: 7/23/15 13:38 Page 3 FITTING NAME TABLE ABBREV. NAME C Coupling E 90 ' Standard Elbow F 45' Elbow S Straight Flow Thru Tee T 90 ' Flow Thru Tee V Valve LEGEND HYD REF Hydraulic reference. Refer to accompanying flow diagram. K FACTOR Flow factor for open head or path where Flow (gpm) = K x -\/P Qa Flow added or subtracted Qt Total flow DIA Actual internal diameter of pipe C Hazen Williams pipe roughness factor Pf/ft Friction loss per foot of pipe PIPE Length of pipe FTNG'S Number of fittings. See table above. TOTAL Total length (PIPE + FTNG'S) Pt Total pressure (psi) at fitting Pe Pressure due to change in elevation where Pe = 0 . 433 x change in elevation Pf Friction loss (psi) to fitting where Pf = 1 x 4 .52 x (Q/C) ^1. 85 / ID^4 . 87 Pv Velocity pressure (psi) where Pv = 0. 001123 x Q^2/ID^4 Pn Normal pressure (psi) , where Pn = Pt - Pv NOTES: - Pressures are balanced to 0. 01 psi. Pressures are listed to 0. 1 psi. Addition may vary by 0. 1 psi due to accumulation of round off. - Calculations conform to NFPA 13. - Velocity Pressures are not considered in these Calculations F.R.E.E. Drawing Date: 7/23/15 13:38 • Page 4 NODE ELEVATION SPRINKLER PRESSURE ACTUAL MINIMUM ACTUAL NUMBER K-FACTOR FLOW FLOW DENSITY (FT) (GPM/ (PSI^ ) ) (PSI) (GPM) (GPM) (GPM/SQ.FT) 1B 11. 00 4 .20 9. 3 12. 8 12 . 8 0 . 05 2B 11. 00 4 .20 9.3 12 . 8 12 . 8 0. 05 3B 11. 00 4 .20 11.5 14 .3 12 . 8 0 . 06 4B 11 . 00 4 .20 11 .7 14 . 4 12 . 8 0 . 06 10 11. 00 16. 9 11 11. 00 16. 6 13 -2 . 00 22 .5 17 -2. 00 22.5 18 -2. 00 22 .5 19 -2. 00 22.5 23 -2 . 00 22. 6 24 11. 00 16. 9 25 11 . 00 16.8 26 11 .00 12 .2 27 11. 00 12 .2 28 11. 00 12 . 0 29 11. 00 11 . 5 30 11. 00 9. 6 31 11. 00 9.3 50 11. 00 16. 8 W 11. 00 17 . 0 Max velocity of 8 .72 occurs in the pipe from 26 TO 11 F.R.E.E. Drawing Date: 7/23/15 13:38 Tyco Fire Products Page 5 HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG'S Pe Pv ******* NOTES ******* POINT Qt Pf/ft TOTAL Pf Pn PATH 1 FROM HYDRAULIC REFERENCE 1B TO W (PRIMARY PATH) 12 . 80 1 . 109 0 . 16 9.3 9.3 K = 4 .20 1B C=150 0. 00 0. 0 0 . 0 12 .80 0. 029 0. 16 0 . 0 9.3 Vel = 4.29 1.109 1E 8 . 07 9.3 9.3 31 C=150 3. 96 0. 0 0. 0 12 . 80 0 . 029 12. 03 0 . 3 9.3 Vel = 4 .29 12 . 84 1. 109 1E 4 . 43 9. 6 9. 6 30 C=150 1T 13.87 0. 0 0 . 0 See PATH 2 25. 64 0 .104 18 .30 1. 9 9. 6 Vel = 8 . 60 14 .26 1. 602 1T 5.75 11.5 11.5 29 C=150 11 . 80 0.0 0 .0 See PATH 3 39. 90 0 . 039 17 . 55 0.7 11.5 Vel = 6.41 14 .36 1. 602 2E 27 .26 12 .2 12 .2 26 C=150 2T 35. 40 0.0 0. 0 See PATH 4 54 .25 0. 069 62 . 66 4 .3 12 .2 Vel = 8 . 72 -26.73 2. 003 2T 15.02 16. 6 16. 6 11 C=150 25. 93 0 . 0 0 . 0 See PATH 5 27 .52 0. 007 40. 95 0 .3 16. 6 Vel = 2. 83 2. 003 1E 2 . 48 16. 9 16. 9 10 0=150 1T 19. 45 0. 0 0. 0 27 .52 0 . 007 21. 93 0. 1 16. 9 Vel = 2 . 83 W 27 .52 17. 0 K = 6. 67 PATH 2 FROM HYDRAULIC REFERENCE 2B TO 30 12 . 84 1. 109 1T 0.16 9.3 9.3 K = 4 .20 2B C=150 9. 91 0. 0 0. 0 12 .84 0. 029 10. 07 0.3 9.3 Vel = 4 .31 30 12 . 84 9. 6 K = 4 . 14 PATH 3 FROM HYDRAULIC REFERENCE 3B TO 29 UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) F.R.E.E. Drawing Date: 7/23/15 13:38 Tyco Fire Products Page 6 HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG' S Pe Pv ******* NOTES ******* POINT Qt Pf/ft TOTAL Pf Pn PATH 3 FROM HYDRAULIC REFERENCE 3B TO 29 CONTINUED 14 .26 1 . 109 0.46 11.5 11 . 5 K = 4 .20 3B C=150 0 . 00 0. 0 0. 0 14.26 0. 035 0. 46 0.0 11. 5 Vel = 4.78 29 14 .26 11 .5 K = 4 .20 PATH 4 FROM HYDRAULIC REFERENCE 4B TO 26 14 .36 1 . 109 1T 0.36 11 . 7 11 . 7 K = 4 .20 4B C=150 9. 91 0. 0 0 . 0 14 . 36 0. 036 10 .27 0. 4 11 .7 Vel = 4 . 81 1. 109 1E 1. 04 12 . 0 12 . 0 28 C=150 3. 96 0. 0 0 . 0 14 .36 0. 036 5. 00 0.2 12. 0 Vel = 4. 81 1. 602 1. 05 12.2 12 .2 27 C=150 0 . 00 0.0 0. 0 14.36 0. 006 1. 05 0. 0 12 .2 Vel = 2 .31 26 14.36 12 .2 K = 4 . 10 PATH 5 FROM HYDRAULIC REFERENCE 11 TO W 26.73 2 . 003 28 . 49 16. 6 16. 6 11 C=150 0 . 00 0. 0 0 . 0 See PATH 1 26.73 0. 006 28 . 49 0.2 16. 6 Vel = 2 . 75 -11. 83 2. 003 3T 40 . 73 16. 8 16. 8 25 C=150 38 . 89 0. 0 0 . 0 See PATH 6 14 . 91 0. 002 79. 63 0.2 16. 8 Vel = 1.53 11.83 2 . 635 1E 2 .52 16. 9 16. 9 24 C=120 1T 24 .71 0 . 0 0 . 0 See PATH 6 26.73 0 . 003 27 .23 0. 1 16. 9 Vel = 1 .59 UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) F.R.E.E. Drawing Date: 7/23/15 13:38 Tyco Fire Products Page 7 HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG'S Pe Pv ******* NOTES ******* POINT Qt Pf/ft TOTAL Pf Pn W 26.73 17 .0 K = 6. 48 PATH 6 FROM HYDRAULIC REFERENCE 25 TO 24 11. 83 2 . 003 2E 30 . 02 16. 8 16. 8 25 C=150 1T 25. 93 0. 0 0. 0 See PATH 5 11. 83 0. 001 55. 94 0. 1 16. 8 Vel = 1.22 2 . 635 1T 13. 00 16. 8 16.8 50 0=120 16. 47 5. 6 0.0 11.83 0. 001 29. 47 0. 0 16. 8 Vel = 0 .70 2 . 635 1T 6.58 22.5 22 . 5 13 0=120 16. 47 0 . 0 0 . 0 11 . 83 0 .001 23. 06 0 . 0 22 .5 Vel = 0 .70 2 . 635 1E 11 .23 22 .5 22 .5 17 C=120 8 .24 0.0 0. 0 11. 83 0. 001 19. 47 0 .0 22 .5 Vel = 0 . 70 2 . 635 1T 15. 44 22 .5 22.5 18 0=120 16. 47 0. 0 0. 0 11. 83 0. 001 31 . 91 0. 0 22.5 Vel = 0 . 70 2 . 635 1E 24 .02 22.5 22. 5 19 C=120 8 .24 0. 0 0 . 0 11. 83 0. 001 32 .25 0 . 0 22 . 5 Vel = 0.70 2 . 635 2E 14. 08 22 . 6 22 . 6 23 0=120 16. 47 -5. 6 0.0 11.83 0 . 001 30 . 55 0.0 22 . 6 Vel = 0.70 24 11 . 83 16. 9 K = 2. 87 UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) Job Water Required Hose Allowance F.R.E.E. Static Pres: 73.0 psi Pressure: 36.1 psi In: 0 gpm 9625 Main Bayview Road Resid. Pres: 46.0 psi Sys Flow. 154 gpm Out: 0 gpm Southold, New York, 11971 Flow: 2173 gpm Sys+Hose: 154 gpm Remote Area: 2 Date. 7-2-15 Safety Pres: 36.7 psi Loc. Hd Ely Pres. 0.0 psi 140 - 120 100 - 80 S • Supply 60 - 40 20 - 100 150 200 250 300 350 400 450 500 Flow (gpm) w F.R.E.E. Drawing Date: 7/23/15 13:38 i HYDRAULIC DESIGN INFORMATION SHEET Job Name: F.R.E.E. Location: 9625 Main Bayview Road Southold, New York, 11971 Drawing Date: Remote Area Number: 1 Contractor: BK Fire Suppresion & Security Systems Telephone: 631-273-2010 826 Suffolk Ave Brentwood, New York, 11717 Designer: RF Calculated By:SprinkCAD www.sprinkcad.com 451 N. Cannon Ave. Lansdale, PA 19446 Construction: Wood Frame Occupancy:Residential Reviewing Authorities:Villiage of Southold SYSTEM DESIGN Code:NFPA 13R Hazard:light System Type:WET Area of Sprinkler Oper. sq ft! Sprinkler or Nozzle Density (gpm/sq ft) RES 1 Make: TYCO Area per Sprinkler 256. 0 sq ftl Model: LFII Hose Allowance Inside 0 gpm 1 K-Factor: 4 .20 Hose Allowance Outside 0 gpm 1 Temperature Rating: 155 CALCULATION SUMMARY 4 Flowing Outlets gpm Required: 152.2 psi Required: 42.1 @ Source WATER SUPPLY Water Flow Test Pump Data Date of Test 7-2-15 Rated Capacity 0 gpm Static Pressure 73. 0 psi Rated Pressure 0. 0 psi Residual Pres 46. 0 psi Elevation 0 At a Flow of 2173 gpm Make: Elevation 0" Model: Location: Source of Information: SCWA SYSTEM VOLUME 93 Gallons Notes: 1A;4.N• RES/V 4.0A I, , -•'--ti- t 0 *\t ‘/‘ 17 f :;e:A7? n 1%04_ " i „Icy, R' THE1.-;0Q. F.R.E.E. Drawing Date: 7/23/15 13:38 HYDRAULIC CALCULATION DETAILS HYDRAULIC FLOW LOSS QTY DESCRIPTION LENGTH C ID gpm psi TOTALS Hydr Ref W Required at Hyd Area 1 52 23.2 psi 1 2" CPVC 90 Ell 9' 120 2 . 067 52 0.3 1 Pipe 2" PVx15 BlazeMa Plastic 5' 150 2. 003 52 0. 1 1 2" Thrd Back Flow Valve Wilkins " CHART LOSS 52 13.2 2 2" Sweatd 90 Ell 11 ' 120 2 . 067 52 0. 4 1 Pipe 2" Kx20 Copper 60' 150 1. 959 52 1 . 5 Elevation Change 8 ' 0" 3.5 Fixed Flow Flow Loss 100 gpm Hydr Ref R1 Required at Source 152 42.1 psi Water Source 73 . 0 psi static, 46.0 psi residual @ 2173 gpm 152 gpm 72.8 psi SAFETY PRESSURE 30.7 psi Available Pressure of 72.8 psi Exceeds Required Pressure of 42.1 psi This is a safety margin of 30.7 psi or 42 % of Supply Maximum Water Velocity is 8 . 6 fps ,1 e51 F.R.E.E. Drawing Date: 7/23/15 13:38 Page 3 FITTING NAME TABLE ABBREV. NAME C Coupling E 90 ' Standard Elbow F 45' Elbow S Straight Flow Thru Tee T 90' Flow Thru Tee V Valve LEGEND HYD REF Hydraulic reference. Refer to accompanying flow diagram. _ K FACTOR Flow factor for open head or path where Flow (gpm) = K x -\/P Qa Flow added or subtracted Qt Total flow DIA Actual internal diameter of pipe C Hazen Williams pipe roughness factor Pf/ft Friction loss per foot of pipe PIPE Length of pipe FTNG'S Number of fittings . See table above. TOTAL Total length (PIPE + FTNG'S) Pt Total pressure (psi) at fitting Pe Pressure due to change in elevation where Pe = 0.433 x change in elevation Pf Friction loss (psi) to fitting where Pf = 1 x 4 . 52 x (Q/C) ^1. 85 / ID^4 .87 Pv Velocity pressure (psi) where Pv = 0. 001123 x Q^2/ID^4 Pn Normal pressure (psi) , where Pn = Pt - Pv NOTES: - Pressures are balanced to 0. 01 psi. Pressures are listed to 0. 1 psi. Addition may vary by 0. 1 psi due to accumulation of round off. - Calculations conform to NFPA 13. - Velocity Pressures are not considered in these Calculations F.R.E.E. Drawing Date: 7/23/15 13:38 Page 4 NODE ELEVATION SPRINKLER PRESSURE ACTUAL MINIMUM ACTUAL NUMBER K-FACTOR FLOW FLOW DENSITY (FT) (GPM/ (PSI^ ) ) (PSI) (GPM) (GPM) (GPM/SQ.FT) lA 20. 00 4 .20 9. 4 12 . 8 12. 8 0 . 05 2A 20. 00 4 .20 9.3 12 . 8 12 . 8 0 . 05 3A 20. 00 4 .20 9.7 13. 1 12 . 8 0. 05 4A 20 . 00 4 .20 10.3 13.5 12 . 8 0. 05 10 11. 00 22. 9 11 11. 00 23 . 0 13 -2 . 00 28 . 8 17 -2 . 00 28 . 8 18 -2 . 00 28 . 8 19 -2. 00 28 . 8 23 -2 . 00 28 . 8 24 11. 00 23.2 25 11. 00 23.1 32 20. 00 18 . 0 34 20. 00 10. 0 35 20. 00 9. 6 36 20. 00 9. 4 40 11. 00 22. 9 41 20. 00 10 . 6 50 11. 00 23.1 W 11. 00 23.2 Max velocity of 8 . 60 occurs in the pipe from 35 TO 34 F.R.E.E. Drawing Date: 7/23/15 13:38 Tyco Fire Products Page 5 HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG'S Pe Pv ******* NOTES ******* POINT Qt Pf/ft TOTAL Pf Pn PATH 1 FROM HYDRAULIC REFERENCE 2A TO W (PRIMARY PATH) 12. 80 1. 109 1T 0.33 9.3 9.3 K = 4 .20 2A C=150 9. 91 0. 0 0. 0 12. 80 0 . 029 10.24 0.3 9.3 Vel = 4 .29 12 . 84 1 . 109 4 .22 9. 6 9. 6 35 C=150 0 . 00 0. 0 0 .0 See PATH 2 25. 64 0 . 104 4 .22 0 .4 9. 6 Vel = 8 . 60 13.07 1. 602 1T 3.45 10. 0 10. 0 34 C=150 11. 80 0. 0 0. 0 See PATH 3 38 .72 0. 037 15.25 0. 6 10. 0 Vel = 6.22 13. 46 1. 602 6E 67. 64 10 . 6 10 . 6 41 C=150 1T 47 .20 0. 0 0 . 0 See PATH 4 52. 17 0 . 065 114 . 84 7 . 4 10 . 6 Vel = 8 .39 1. 602 1E 9. 00 18 . 0 18 . 0 32 C=150 5. 90 3.9 0 . 0 52 . 17 0 . 065 14 . 90 1.0 18 .0 Vel = 8 .39 2 . 003 0 . 95 22 . 9 22 . 9 40 C=150 0. 00 0. 0 0. 0 52 . 17 0 . 022 0. 95 0. 0 22 . 9 Vel = 5.36 -19.24 2 . 003 1E 2 . 48 22. 9 22 . 9 10 C=150 2T 32 . 41 0. 0 0. 0 See PATH 5 32 . 94 0 . 009 34 . 89 0.3 22 . 9 Vel = 3. 39 W 32 . 94 23.2 K = 6. 84 PATH 2 FROM HYDRAULIC REFERENCE 1A TO 35 12. 84 1. 109 1.34 9. 4 9. 4 K = 4 .20 1A C=150 0.00 0. 0 0. 0 12. 84 0 . 029 1.34 0. 0 9. 4 Vel = 4 .31 1 . 109 1E 2 . 66 9. 4 9. 4 36 C=150 3. 96 0. 0 0. 0 12. 84 0. 029 6. 62 0.2 9. 4 Vel = 4 .31 UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) F.R.E.E. Drawing Date: 7/23/15 13:38 , Tyco Fire Products Page 6 HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG'S Pe Pv ******* NOTES ******* POINT Qt Pf/ft TOTAL Pf Pn 35 12. 84 9. 6 K = 4 . 15 PATH 3 FROM HYDRAULIC REFERENCE 3A TO 34 13.07 1 . 109 1T 1.34 9.7 9.7 K = 4 .20 3A C=150 9. 91 0 . 0 0. 0 13. 07 0 . 030 11.24 0 .3 9.7 Vel = 4 .38 34 13. 07 10. 0 K = 4 . 13 PATH 4 FROM HYDRAULIC REFERENCE 4A TO 41 13. 46 1. 109 1T 0.21 10 .3 10 .3 K = 4 .20 4A C=150 9. 91 0 . 0 0 . 0 13.46 0 . 032 10 . 11 0.3 10.3 Vel = 4 .51 41 13. 46 10. 6 K = 4. 14 PATH 5 FROM HYDRAULIC REFERENCE 10 TO W 19.24 2 .003 1T 15. 02 22 . 9 22 . 9 10 0=150 12 . 96 0 . 0 0. 0 See PATH 1 19.24 0 . 003 27. 99 0 . 1 22 . 9 Vel = 1. 98 2 . 003 28 . 49 23. 0 23. 0 11 C=150 0 . 00 0.0 0.0 19.24 0. 003 28 . 49 0.1 23. 0 Vel = 1. 98 -8 .51 2 . 003 3T 40 .73 23. 1 23. 1 25 C=150 38 . 89 0 . 0 0. 0 See PATH 6 10 .73 0.001 79. 63 0 .1 23. 1 Vel = 1 . 10 8 . 51 2. 635 1E 2 .52 23.2 23.2 24 C=120 1T 24 .71 0 . 0 0. 0 See PATH 6 19.24 0 . 001 27 .23 0.0 23.2 Vel = 1. 14 UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) l F.R.E.E. Drawing Date: 7/23/15 13:38 Tyco Fire Products Page 7 HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG' S Pe Pv ******* NOTES ******* POINT Qt Pf/ft TOTAL Pf Pn W 19.24 23.2 K = 3. 99 PATH 6 FROM HYDRAULIC REFERENCE 25 TO 24 8 .51 2 .003 2E 30. 02 23. 1 23. 1 25 C=150 1T 25. 93 0 . 0 0 . 0 See PATH 5 8 .51 0. 001 55. 94 0 . 0 23. 1 Vel = 0. 88 2. 635 1T 13. 00 23.1 23. 1 50 0=120 16.47 5. 6 0. 0 8 .51 0 . 000 29.47 0. 0 23. 1 Vel = 0 . 51 2 . 635 1T 6.58 28 . 8 28 . 8 13 0=120 16. 47 0 . 0 0 . 0 8 .51 0.000 23. 06 0 . 0 28 .8 Vel = 0.51 2 . 635 lE 11.23 28 .8 28 . 8 17 C=120 8 .24 0. 0 0 . 0 8 .51 0. 000 19.47 0 . 0 28 . 8 Vel = 0.51 2 . 635 1T 15. 44 28 . 8 28 .8 18 0=120 16. 47 0 . 0 0.0 8 .51 0 .000 31 . 91 0 . 0 28 .8 Vel = 0.51 2. 635 1E 24 . 02 28 .8 28 .8 19 C=120 8 .24 0.0 0.0 8 .51 0. 000 32 .25 0.0 28 . 8 Vel = 0.51 2. 635 2E 14 .08 28 .8 28 . 8 23 0=120 16. 47 -5. 6 0. 0 8 .51 0. 000 30. 55 0. 0 28 . 8 Vel = 0 .51 24 8 . 51 23.2 K = 1.77 UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) Job Water Required Hose Allowance • F.R.E.E. Static Pres. 73.0 psi Pressure: 42.1 psi In: 0 gpm 9625 Main Bayview Road Resid. Pres: 46.0 psi Sys Flow. 152 gpm Out: 0 gpm Southold, New York, 11971 Flow: 2173 gpm Sys+Hose: 152 gpm Remote Area: 1 Date: 7-2-15 Safety Pres: 30.7 psi Loc: Hd Ely Pres. 3.9 psi 140 - 120 - 100 • P 80 - S • Supply 60 • 40 20 111-3.9 psi - I 100 150 200 250 300 350 400 450 500 Flow (gpm) F.R.E.E. Drawing Date: 12/ 1/15 15:10 HYDRAULIC DESIGN INFORMATION SHEET Job Name: F.R.E.E. Location: 9625 Main Bayview Road Southold, New York, 11971 Drawing Date: Remote Area Number: 2 Contractor: BK Fire Suppresion & Security Systems Telephone: 631-273-2010 826 Suffolk Ave Brentwood, New York, 11717 Designer: RF Calculated By:SprinkCAD www.sprinkcad.com 451 N. Cannon Ave. Lansdale, PA 19446 Construction: Wood Frame Occupancy:Residential Reviewing Authorities:Villiage of Southold SYSTEM DESIGN Code:NFPA 13R Hazard:residential System Type:WET Area of Sprinkler Oper. sq ftl Sprinkler or Nozzle Density (gpm/sq ft) RES I Make: TYCO Area per Sprinkler 256 . 0 sq ftl Model: LFII Hose Allowance Inside 0 gpm I K-Factor: 4 .20 Hose Allowance Outside 0 gpm I Temperature Rating: 155 CALCULATION SUMMARY 4 Flowing Outlets gpm Required: 153 .1 psi Required: 53 .2 @ Source WATER SUPPLY Water Flow Test Pump Data Date of Test 7-2-15 Rated Capacity 0 gpm Static Pressure 73 . 0 psi Rated Pressure 0 . 0 psi Residual Pres 46 . 0 psi Elevation 0 At a Flow of 2173 gpm Make: Elevation 0" Model: Location: Source of Information: SCWA SYSTEM VOLUME 74 Gallons Notes: / 7„,wkILDARN , 1, itf.. ,,,t,, ,,,,;i.,),0 * \ ii , izii,,,,.:A, e al2 •Fpm'4 , O. ao�z''1oe.i , THE suit r A F.R.E.E. Drawing Date: 12/ 1/15 15:10 , HYDRAULIC CALCULATION DETAILS HYDRAULIC FLOW LOSS QTY DESCRIPTION LENGTH C ID gpm psi TOTALS Hydr Ref W Required at Hyd Area 2 53 33 .3 psi 1 1-1/2" CPVC 90 Ell 7 ' 120 1 .610 53 1. 0 1 Pipe 1%" PVx15 5 ' 150 1.602 53 0 . 3 1 2" Thrd Back Flow Valve Wilkins " CHART LOSS 53 13 .2 2 2" Sweatd 90 Ell 11 ' 120 2 . 067 53 0 .4 1 Pipe 2" Kx21 Copper 60 ' 150 1 . 962 53 1 . 5 Elevation Change 8 ' 0" 3 . 5 Fixed Flow Flow Loss 100 gpm Hydr Ref R1 Required at Source 153 53.2 psi Water Source 73 . 0 psi static, 46 . 0 psi residual @ 2173 gpm 153 gpm 72.8 psi SAFETY PRESSURE 19.6 psi Available Pressure of 72 .8 psi Exceeds Required Pressure of 53 .2 psi This is a safety margin of 19.6 psi or 27 % of Supply Maximum Water Velocity is 8 .6 fps F.R.E.E. Drawing Date: 12/ 1/15 15:10 Page 3 FITTING NAME TABLE ABBREV. NAME C Coupling E 90 ' Standard Elbow F 45 ' Elbow S Straight Flow Thru Tee T 90 ' Flow Thru Tee ✓ Valve LEGEND HYD REF Hydraulic reference. Refer to accompanying flow diagram. _ K FACTOR Flow factor for open head or path where Flow (gpm) = K x -\/P Qa Flow added or subtracted Qt Total flow DIA Actual internal diameter of pipe C Hazen Williams pipe roughness factor Pf/ft Friction loss per foot of pipe PIPE Length of pipe FTNG' S Number of fittings . See table above. TOTAL Total length (PIPE + FTNG' S) Pt Total pressure (psi) at fitting Pe Pressure due to change in elevation where Pe = 0 .433 x change in elevation Pf Friction loss (psi) to fitting where Pf = 1 x 4 . 52 x (Q/C) A1. 85 / IDA4 . 87 Pv Velocity pressure (psi) where Pv = 0 . 001123 x QA2/IDA4 Pn Normal pressure (psi) , where Pn = Pt - Pv NOTES: - Pressures are balanced to 0 . 01 psi . Pressures are listed to 0 . 1 psi . Addition may vary by 0 . 1 psi due to accumulation of round off. - Calculations conform to NFPA 13 . - Velocity Pressures are not considered in these Calculations I F.R.E.E. Drawing Date: 12/ 1/15 15:10 Page 4 NODE ELEVATION SPRINKLER PRESSURE ACTUAL MINIMUM ACTUAL NUMBER K-FACTOR FLOW FLOW DENSITY (FT) (GPM/ (PSIN) ) (PSI) (GPM) (GPM) (GPM/SQ.FT) 1B 20 . 00 4 .20 9 . 3 12 . 8 12 . 8 0 . 05 2B 20 . 00 4 .20 9 . 3 12 . 8 12 . 8 0 . 05 3B 20 . 00 4 .20 10 . 6 13 . 7 12 . 8 0 . 05 4A -2 . 00 38 . 8 4B 20 . 00 4 .20 10 . 8 13 . 8 12 . 8 0 . 05 10 -2 . 00 38 . 9 11 20 . 00 11. 7 12 20 . 00 10 . 9 13 20 . 00 9 .6 Al 11. 00 33 . 0 A2 11. 00 33 . 0 A3 11. 00 33 .2 B1 11 . 00 32 . 5 Cl 20 . 00 11 .2 C2 20 . 00 11 .3 D1 0 . 88 37 . 5 D2 11. 00 33 . 1 El -2 . 00 38 . 8 E2 -2 . 00 38 . 8 E3 -2 . 00 38 . 8 Fl 11. 00 33 . 1 F2 11 . 00 33 . 1 G1 11 . 00 33 . 0 H1 -2 . 00 38 . 8 W 11. 00 33 .3 Max velocity of 8 . 60 occurs in the pipe from 12 TO 13 t F.R.E.E. Drawing Date: 12/ 1/15 15:10 Tyco Fire Products Page 5 ta^Rrasi.0.0 t1,0.atE101u^.v.-,,,,,,,Eorte+'d^.^'s.s`', ,,,C:T ,. ,,,M,,V.- f%gt,e,+mYS,t.2,,,,V,+.=M 0 0&-tea..,.»., '70, ,--,,,,,0,A. W,0,,,,4. ..., rzs ...,, , :w�-., -,,,,,,o,0,,,,,L,,,, i .. ^rvc„ ,,, ,-r m) HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG' S Pe Pv ******* NOTES ******* POINT Qt Pf/ft TOTAL Pf Pn PATH 1 FROM HYDRAULIC REFERENCE 1B TO W (PRIMARY PATH) 12 . 80 1. 109 1E 8 .33 9 . 3 9 .3 K = 4 .20 133 C=150 3 . 96 0 . 0 0 . 0 12 . 80 0 . 029 12 .30 0 .4 9 .3 Vel = 4 .29 12 . 84 1. 109 1E 8 . 51 9 .6 9 .6 13 C=150 3 . 96 0 . 0 0 . 0 See PATH 2 25 .64 0 . 104 12 .47 1.3 9 . 6 Vel = 8 .60 13 . 68 1. 602 1E 3 .16 10 . 9 10 . 9 12 C=150 5 . 90 0 . 0 0 . 0 See PATH 3 39 . 32 0 . 038 9 . 06 0 .3 10 . 9 Vel = 6 .32 13 . 82 1 . 602 5 . 58 11.3 11.3 C2 C=150 0 . 00 0 . 0 0 . 0 See PATH 4 53 . 14 0 . 067 5 . 58 0 .4 11.3 Vel = 8 . 54 1.602 13E 130 . 03 11 . 7 11. 7 11 C=150 4T 123 . 89 3 . 9 0 . 0 53 . 14 0 . 067 253 . 92 17 . 0 11. 7 Vel = 8 . 54 -12 . 79 1 .602 1E 2 .48 32 . 5 32 . 5 B1 C=150 1T 17 . 70 0 . 0 0 . 0 See PATH 5 40 .35 0 . 040 20 . 18 0 . 8 32 . 5 Vel = 6 .49 W 40 .35 33 .3 K = 6 . 99 eax 4t..,M.a.0 4 , .,�&,rz-rsa gmXP'( 1 , ,.-t M. ..- .., i t'L,:mfld2 Ue.:a.. , ». c a^. ., C. ..x e.••,"S", ,o .... , ,',a, ^,.x m,_ :rr,..a. .a .....,..,c..r._.w .^E,± .. x" ,n,Y,') PATH 2 FROM HYDRAULIC REFERENCE 2B TO 13 12 . 84 1. 109 1T 0 .33 9 .3 9 .3 K = 4 .20 2B C=150 9 . 91 0 . 0 0 . 0 12 . 84 - 0 . 029 10 .24 - 0 .3 9 .3 Vel = 4 . 31 13 12 . 84 9 .6 K = 4 . 13 PATH 3 FROM HYDRAULIC REFERENCE 3B TO 12 UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) F.R.E.E. Drawing Date: 12/ 1/15 15:10 Tyco Fire Products Page 6 . ..._ _ _. -,._ ,. _ _ r HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG' S Pe Pv ******* NOTES ******* POINT Qt Pf/ft TOTAL Pf Pn PATH 3 FROM HYDRAULIC REFERENCE 3B TO 12 CONTINUED 13 .68 1 . 109 1T 0 . 36 10 .6 10 . 6 K = 4 .20 3B C=150 9 . 91 0 . 0 0 . 0 13 .68 0 . 033 10 .26 0 . 3 10 . 6 Vel = 4 . 59 12 13 . 68 10 . 9 K = 4 . 14 PATH 4 FROM HYDRAULIC REFERENCE 4B TO C2 13 . 82 1. 109 1T 1 . 14 10 . 8 10 . 8 K = 4 .20 4B C=150 9 . 91 0 . 0 0 . 0 13 . 82 0 . 033 11 . 04 0 .4 10 . 8 Vel = 4 . 64 1.602 1T 4 . 78 11 .2 11 .2 Cl C=150 11 . 80 0 . 0 0 . 0 13 . 82 0 . 006 16 . 58 0 . 1 11 .2 Vel = 2 .22 C2 13 . 82 11 .3 K = 4 . 11 - -. „ PATH 5 FROM HYDRAULIC REFERENCE B1 TO W 12 . 79 1.602 4E 60 . 53 32 . 5 32 . 5 B1 C=150 1T 41 .30 0 . 0 0 . 0 See PATH 1 12 . 79 0 . 005 2F 101. 82 0 . 5 32 . 5 Vel = 2 . 06 -4 .34 1 . 602 2E 60 . 07 33 . 0 33 . 0 A2 C=150 2T 41.30 0 . 0 0 . 0 See PATH 6 8 .44 0 . 002 2F 101.36 0 .2 33 . 0 Vel = 1 .36 4 .34 1.602 1E 2 . 52 33 .2 33 .2 A3 C=150 iT 17 . 70 0 . 0 0 . 0 See PATH 6 12 . 79 0 . 005 20 .22 0 . 1 33 .2 Vel = 2 . 06 W 12 . 79 33 .3 K = 2 .22 PATH 6 FROM HYDRAULIC REFERENCE A2 TO A3 UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) F.R.E.E. Drawing Date: 12/ 1/15 15:10 Tyco Fire Products Page 7 HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG' S ' Pe Pv ******* NOTES ******* POINT Qt Pf/ft TOTAL Pf Pn PATH 6 FROM HYDRAULIC REFERENCE A2 TO A3 CONTINUED 4 .34 1 . 602 lE 6 . 52 33 . 0 33 . 0 A2 C=150 5 . 90 0 . 0 0 . 0 See PATH 5 4 .34 0 . 001 12 .42 0 . 0 33 . 0 Vel = 0 . 70 1. 109 2-. 72 33 . 0 33 . 0 Al C=150 0 . 00 0 . 0 0 . 0 4 .34 0 . 004 2 . 72 0 . 0 33 . 0 Vel = 1 .46 1.602 3E 39 .48 33 . 0 33 . 0 G1 C=150 1T 29 . 50 0 . 0 0 . 0 4 .34 0 . 001 68 . 98 0 . 0 33 . 0 Vel = 0 . 70 1 . 602 2E 22 . 06 33 . 1 33 . 1 D2 C=150 2T 35 .40 0 . 0 0 . 0 4 .34 0 . 001 57 .46 0 . 0 33 . 1 Vel = 0 . 70 -0 . 92 1 . 602 1E 13 . 67 33 . 1 33 . 1 F2 C=150 2T 29 . 50 5 .6 0 . 0 See PATH 7 3 .42 0 . 000 43 . 17 0 . 0 33 . 1 Vel = 0 . 55 0 . 92 1 .610 3E 39 . 08 38 . 8 38 . 8 Hi C=120 1T 20 . 00 0 . 0 0 . 0 See PATH 7 4 .34 0 . 001 59 . 08 0 . 1 38 . 8 Vel = 0 .69 1 . 610 lE 18 . 78 38 . 8 38 . 8 E3 C=120 iT 12 . 00 0 . 0 0 . 0 4 .34 0 . 001 30 . 78 0 . 0 38 . 8 Vel = 0 .69 1. 602 1E 13 .48 38 . 9 38 . 9 10 C=150 iT 17 . 70 -5 .6 0 . 0 4 .34 0 . 001 31. 18 0 . 0 38 . 9 Vel = 0 . 70 A3 4 .34 33 .2 K = 0 . 75 PATH 7 FROM HYDRAULIC REFERENCE F2 TO H1 0 . 92 1 .602 4E 34 . 15 33 .1 33 . 1 F2 C=150 23 .60 0 . 0 0 . 0 See PATH 6 0 . 92 0 . 000 57 . 75 0 . 0 33 . 1 Vel = 0 . 15 UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) 2 F.R.E.E. Drawing Date: 12/ 1/15 15:10 Tyco Fire Products Page 8 HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG' S Pe Pv ******* NOTES ******* POINT Qt Pf/ft TOTAL Pf Pn PATH 7 FROM HYDRAULIC REFERENCE F2 TO H1 CONTINUED 1. 049 1E 10 . 13 33 . 1 33 . 1 Fl C=120 2 . 00 4 .4 0 . 0 0 . 92 0 . 000 12 . 13 0 . 0 33 . 1 Vel = 0 . 35 1 . 049 1E 16 . 90 37 . 5 37 . 5 D1 C=120 2 . 00 1 .2 0 . 0 0 . 92 0 . 000 18 . 90 0 . 0 37 . 5 Vel = 0 .35 1 . 049 lE 1 . 88 38 . 8 38 . 8 4A C=120 2 . 00 0 . 0 0 . 0 0 . 92 0 . 000 3 . 88 0 . 0 38 . 8 Vel = 0 . 35 1.602 3 . 75 38 . 8 38 . 8 El C=150 0 . 00 0 . 0 0 . 0 0 . 92 0 . 000 3 . 75 0 . 0 38 . 8 Vel = 0 . 15 1 . 610 7 . 03 38 . 8 38 . 8 E2 C=120 0 . 00 0 . 0 0 . 0 0 . 92 0 . 000 7 . 03 0 . 0 38 . 8 Vel = 0 . 15 H1 0 . 92 38 . 8 K = 0 . 15 UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) Job Water Required Hose Allowance • F.R.E.E. Static Pres: 73.0 psi Pressure: 53.2 psi In: 0 gpm 9625 Main Bayview Road Resid. Pres: 46.0 psi Sys Flow: 153 gpm Out: 0 gpm Southold, New York, 11971 Flow: 2173 gpm Sys+Hose: 153 gpm Remote Area: 2 Date: 7-2-15 Safety Pres: 19.6 psi Loc: Hd Ely Pres: 7.4 psi 140 120 - - - 100 P 80 - S • Supply 60 OO 40 20 © 7.4 psi 100 150 200 250 300 350 400 450 500 Flow (gpm) `per/. ' .F.R.E.E. Drawing Date: 12/ 1/15 15: 9 HYDRAULIC DESIGN INFORMATION SHEET Job Name: F.R.E.E. Location: 9625 Main Bayview Road Southold, New York, 11971 Drawing Date: Remote Area Number: 1 Contractor: BK Fire Suppresion & Security Systems Telephone: 631-273-2010 826 Suffolk Ave Brentwood, New York, 11717 Designer: RF Calculated By: SprinkCAD www.sprinkcad.com 451 N. Cannon Ave. Lansdale, PA 19446 Construction: Wood Frame Occupancy:Residential Reviewing Authorities :Villiage of Southold SYSTEM DESIGN Code:NFPA 13Hazard:Ordinary 1 System Type:WET Area of Sprinkler Oper. sq ft1 Sprinkler or Nozzle Density (gpm/sq ft) 0 . 150 1 Make: TYCO Area per Sprinkler 121 . 0 sq ft1 Model: TY-FRB Hose Allowance Inside 0 gpm 1 K-Factor: 5 . 60 Hose Allowance Outside 0 gpm 1 Temperature Rating: 135 CALCULATION SUMMARY 4 Flowing Outlets gpm Required: 329.2 psi Required: 44.1 @ Source WATER SUPPLY Water Flow Test Pump Data Date of Test 7-2-15 Rated Capacity 0 gpm Static Pressure 73 . 0 psi Rated Pressure 0 . 0 psi Residual Pres 46 . 0 psi Elevation 0 At a Flow of 2173 gpm Make: Elevation 0" Model : Location: Source of Information: SCWA SYSTEM VOLUME 74 Gallons Notes : dote® ARel ; , cel t., T�� '�ES , ��N. fie .,,, f1x : =I a f' 4 I � Op THE 50-,,/`-- F.R.E.E. Drawing Date: 12/ 1/15 15: 9 HYDRAULIC CALCULATION DETAILS HYDRAULIC FLOW LOSS QTY DESCRIPTION LENGTH C ID gpm psi TOTALS Hydr Ref W Required at Hyd Area 1 79 20.6 psi 1 1-1/2" CPVC 90 Ell 7 ' 120 1 .610 79 2 . 0 1 Pipe 1%" PVx15 5 ' 150 1 .602 79 0 . 7 1 2" Thrd Back Flow Valve Wilkins " CHART LOSS 79 13 .4 2 2" Sweatd 90 Ell 11 ' 120 2 . 067 79 0 . 8 1 Pipe 2" Kx21 Copper 60 ' 150 1 . 962 79 3 . 1 Elevation Change 8 ' 0" 3 . 5 Fixed Flow Flow Loss 250 gpm Hydr Ref R1 Required at Source 329 44.1 psi Water Source 73 . 0 psi static, 46 . 0 psi residual @ 2173 gpm 329 gpm 72 .2 psi SAFETY PRESSURE 28.1 psi Available Pressure of 72 .2 psi Exceeds Required Pressure of 44.1 psi This is a safety margin of 28.1 psi or 39 % of Supply Maximum Water Velocity is 13 .3 fps F.R.E.E. Drawing Date: 12/ 1/15 15: 9 ' Page 3 FITTING NAME TABLE ABBREV. NAME C Coupling E 90 ' Standard Elbow F 45 ' Elbow S Straight Flow Thru Tee T 90 ' Flow Thru Tee ✓ Valve LEGEND HYD REF Hydraulic reference. Refer to accompanying flow diagram. _ K FACTOR Flow factor for open head or path where Flow (gpm) = K x -\/P Qa Flow added or subtracted Qt Total flow DIA Actual internal diameter of pipe C Hazen Williams pipe roughness factor Pf/ft Friction loss per foot of pipe PIPE Length of pipe FTNG' S Number of fittings . See table above. TOTAL Total length (PIPE + FTNG' S) Pt Total pressure (psi) at fitting Pe Pressure due to change in elevation where Pe = 0 .433 x change in elevation Pf Friction loss (psi) to fitting where Pf = 1 x 4 . 52 x (Q/C) '1 . 85 / IDA4 . 87 Pv Velocity pressure (psi) where Pv = 0 . 001123 x QA2/ID.4 Pn Normal pressure (psi) , where Pn = Pt - Pv NOTES: - Pressures are balanced to 0 . 01 psi. Pressures are listed to 0 . 1 psi . Addition may vary by 0 . 1 psi due to accumulation of round off. - Calculations conform to NFPA 13 . - Velocity Pressures are not considered in these Calculations , F.R.E.E. Drawing Date: 12/ 1/15 15: 9 Page 4 _ NODE ELEVATION SPRINKLER PRESSURE ACTUAL MINIMUM ACTUAL NUMBER K-FACTOR FLOW FLOW DENSITY (FT) (GPM/ (PSI"%) ) (PSI) (GPM) (GPM) (GPM/SQ.FT) 1A -2 . 00 5 . 60 9 . 7 17 . 5 16 .4 0 . 16 2A -2 . 00 5 . 60 10 . 5 18 . 1 18 .2 0 . 15 3A -2 . 00 5 . 60 13 .6 20 . 7 16 . 5 0 . 19 4A -2 . 00 5 .60 16 . 8 22 . 9 14 . 8 0 .27 10 -2 . 00 23 . 5 Al 11. 00 18 .2 A2 11 . 00 18 . 6 A3 11. 00 19 .2 B1 11 . 00 20 . 5 D1 0 . 88 16 . 5 D2 11. 00 15 . 1 El -2 . 00 16 . 9 E2 -2 . 00 16 . 9 E3 -2 . 00 21 . 6 Fl 11 . 00 12 . 8 F2 11 . 00 13 . 1 G1 11. 00 17 . 6 H1 -2 . 00 18 . 0 W 11. 00 20 .6 Max velocity of ' 13 .35 occurs in the pipe from 3A TO 2A F.R.E.E. Drawing Date: 12/ 1/15 15: 9 s Tyco Fire Products Page 5 C rr , muN.. ..£n.. '> '.. .e.•ca .... �•;Kd x" ,...ww.+�'w*'.z.;..:9,:' x5§„af-_„-•x�„'g'n,.,1 ,YFY;'cr9"a^k.+s i:r,] ' , m. « 3T-". .. ._..n rs`c-t , -^:.a,`�s'..,..:s-...,.^4 9:.. +a,.°1 HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG' S Pe Pv ******* NOTES ******* POINT Qt Pf/ft TOTAL Pf Pn ys°-vel.^msu'. x.G•"s?. :C,^M1s2`. a^✓;✓.'."'-..x..,._v.. a. -;xt.+.:nt.r'n im„... .n *etib c..w'f. _ T xo .asg ti:h 3""+CF3131L::.t,s a.m.',y'"tL?7'r'!; . ..,=::.L:.z...x rs .La.m.s .w- _..m,s'..w.4 E .�b, ,`.,1&iia319rd PATH 1 FROM HYDRAULIC REFERENCE 1A TO. W (PRIMARY- PATH) 17 .45 1. 049 7 . 86 9 . 7 9 . 7 K = 5 .60 1A C=120 0 . 00 0 . 0 0 . 0 17 .45 0 . 101 7 . 86 0 . 8 9 . 7 Vel = 6 . 54 18 . 15 1. 049 8 .22 10 . 5 10 . 5 K = 5 .60 2A C=120 0 . 00 0 . 0 0 . 0 35 . 60 0 .378 8 .22 3 . 1 10 . 5 Vel = 13 .35 20 .66 1 . 380 iT 8 .28 13 .6 13 .6 K = 5 . 60 3A C=120 6 . 00 0 . 0 0 . 0 56 .26 0 .232 14 .28 3 . 3 13 . 6 Vel = 12 . 19 10 .43 1. 610 7 . 03 16 . 9 16 . 9 E2 C=120 0 . 00 0 . 0 0 . 0 See PATH 3 66 .69 0 . 150 7 . 03 1 . 1 16 . 9 Vel = 10 .61 -25 .47 1 . 610 3E 39 . 08 18 . 0 18 . 0 H1 C=120 1T 20 . 00 0 . 0 0 . 0 See PATH 4 , 41 .22 0 . 062 59 . 08 3 .6 18 . 0 Vel '= 6 . 56 1.610 1E 18 . 78 21 . 6 21 .6 E3 C=120 iT 12 . 00 0 . 0 0 . 0 41.22 0 . 062 30 . 78 1. 9 21 .6 Vel = 6 . 56 1.602 1E 13 .48 23 . 5 23 . 5 10 C=150 iT 17 . 70 -5 .6 0 . 0 41 .22 0 . 042 31. 18 1 .3 23 . 5 Vel = 6 .63 13 .42 1 .602 lE 2 . 52 19 .2 19 .2 A3 C=150 iT 17 . 70 0 . 0 0 . 0 See PATH 5 54 .64 0 . 070 20 .22 1.4 19 .2 Vel = 8 . 78 W 54 .64 20 .6 K = 12 . 04 PATH 2 FROM HYDRAULIC REFERENCE 4A TO W 12 . 50 1 . 049 1E 16 . 90 16 . 8 16 . 8 K = 3 . 05 4A C=120 2 . 00 -1.2 0 . 0 12 . 50 0 . 055 18 . 90 1. 0 16 . 8 Vel = 4 .69 UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) F.R.E.E. Drawing Date: 12/ 1/15 15: 9 Tyco Fire Products Page 6 _ t HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG' S Pe Pv ******* NOTES ******* POINT Qt Pf/ft TOTAL Pf Pn PATH 2 FROM HYDRAULIC REFERENCE 4A TO W CONTINUED 1 . 049 lE 10 . 13 16 . 5 16 . 5 D1 C=120 2 . 00 -4 .4 0 . 0 12 . 50 0 . 055 12 . 13 0 . 7 16 . 5 Vel = 4 . 69 1 . 602 4E 34 . 15 12 . 8 12 . 8 Fl C=150 23 . 60 0 . 0 0 . 0 12 . 50 0 . 005 57 . 75 0 . 3 12 . 8 Vel = 2 . 01 25 .47 1 .602 2E 22 . 06 13 . 1 13 . 1 F2 C=150 2T 35 .40 0 . 0 0 . 0 See PATH 4 37 . 97 0 . 036 57 .46 2 . 1 13 . 1 Vel = 6 . 10 1.602 3E 39 .48 15 . 1 15 . 1 D2 C=150 iT 29 . 50 0 . 0 0 . 0 37 . 97 0 . 036 68 . 98 2 . 5 15 . 1 Vel = 6 . 10 1. 109 2 . 72 17 .6 17 . 6 G1 C=150 0 . 00 0 . 0 0 . 0 37 . 97 0 .215 2 . 72 0 .6 17 . 6 Vel = 12 . 74 1.602 lE 6 . 52 18 .2 18 .2 Al C=150 5 . 90 0 . 0 0 . 0 37 . 97 0 . 036 12 .42 0 .4 18 .2 Vel = 6 . 10 -13 .42 1.602 4E 60 . 53 18 . 6 18 .6 A2 C=150 2T 53 . 09 0 . 0 0 . 0 See PATH 5 24 . 55 0 . 016 2F 113 . 62 1. 8 18 . 6 Vel = 3 . 95 1.602 1E 2 .48 20 . 5 20 . 5 B1 C=150 5 . 90 0 . 0 0 . 0 24 . 55 0 . 016 8 .38 0 . 1 20 . 5 Vel = 3 . 95 W 24 . 55 20 . 6 K = 5 .41 PATH 3 FROM HYDRAULIC REFERENCE 4A TO E2 10 .43 1 . 049 lE 1 . 88 16 . 8 16 . 8 K = 2 . 55 4A C=120 2 . 00 0 . 0 0 . 0 10 .43 0 . 039 3 . 88 0 .2 16 . 8 Vel = 3 . 91 UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) F.R.E.E. Drawing Date: 12/ 1/15 15: 9 i Tyco Fire Products Page 7 HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG' S Pe Pv ******* NOTES ******* POINT Qt Pf/ft TOTAL Pf Pn ..',Ir.n..)a..:,,,,,,.,`w,,,L44:21-.4 scall erimmsta.r s'r. ,r , r r. ,.rarooneso.M:..sa.1**.,1 & :aw.1er,.„sx=rx-xinn sm axz.-enX.. - , s-:as 4.etirrru:.,a:?+x :ti rrxx.: PATH 3 FROM HYDRAULIC REFERENCE 4A TO E2 CONTINUED 1. 602 3 . 75 16 . 9 16 . 9 El C=150 0 . 00 0 . 0 0 . 0 10 .43 0 . 003 3 . 75 0 . 0 16 . 9 Vel = 1.68 E2 10 .43 16 . 9 K = 2 . 53 PATH 4 FROM HYDRAULIC REFERENCE Hl TO F2 25 .47 1.602 1E 13 .67 18 . 0 18 . 0 H1 C=150 2T 29 . 50 -5 .6 0 . 0 See PATH 1 25 .47 0 . 017 43 . 17 0 . 7 18 . 0 Vel = 4 . 09 F2 25 .47 13 . 1 K = 7 . 04 .Ps4-ri=o5 i%^}yy'dF31Y^ro'-,.....,,,,,,,,-c.,':X. -14 <sy*N' ,h`Ee'?*a.- 'x',aTn*'ei s`rr 1,....,,,,,.,c,i'',-,11.,,,,,,,,,,,.4!'htib.q'w''P,,,--..b>Y=^Fi-t''.t,",",t.'.,4)u''' , "''.'t-L,g."4..-4T-L',1".r,'Y.:.C-s''' ,.t 3'vT-'4S,^6$ PATH 5 FROM HYDRAULIC REFERENCE A2 TO A3 13 .42 1. 602 2E 60 . 07 18 . 6 18 .6 A2 C=150 2T 41 . 30 0 . 0 0 . 0 See PATH 2 13 .42 0 . 005 2F 101 . 36 0 . 5 18 . 6 Vel = 2 . 16 A3 13 .42 19 .2 K = 3 . 07 rf--lL.3%iF•'£V.*XYsr^v R,'Gti..**,*c**,.. ` .. - 0.1.1 VFu +SLAT*** 1&'_ x#1.2.1114 "••"•WXX**1 F-••"^� .L i.2 'a9~I,I.K* UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) Job Water Required Hose Allowance • F.R.E.E. Static Pres: 73.0 psi Pressure: 44.1 psi In: 0 gpm 9625 Main Bayview Road Resid. Pres: 46.0 psi Sys Flow: 329 gpm Out: 0 gpm Southold, New York, 11971 Flow: 2173 gpm Sys+Hose: 329 gpm Remote Area: 1 Date: 7-2-15 Safety Pres: 28.1 psi Loc: Hd Ely Pres: -2.2 psi 140 - — 120 • 100 P 80 S • Suppl 60 - 40 20 100 150 200 250 300 350 400 450 500 Flow (gpm) „kr5 Vie, Worldwide !''° wy Contacts www.tyco-fire.com rte° RAPID RESPONSE Series LFII Residential Sprinklers 4.2 K-factor Horizontal Sidewall Wet Pipe and Dry Pipe Systems General Escutcheon reduces the accuracy to which the pipe nipples to the sprinklers f Description must be cut. r,- `- The Series LFII Residential Sprinklers ' , = �Y`� `;t The TYCO RAPID RESPONSE Series --s•,..."4). %' >= have been designed with heat sensitivity =--_e�_ ti LFII Residential Horizontal Sidewall and water distribution characteristics r,-,� J:_- ' Sprinklers (TY1334) are decorative, proven to help in the control of residen- IL-') - t r; ; 'tl y;° ` fast response,frangible bulb sprinklers tial fires and to improve the chance for fL :�\, �� :_ I "'=:i designed for use in residential occupan- occupants to escape or be evacuated. cies such as homes,apartments,dormi- 1(,� -',`<! tories,and hotels.When aesthetics and Dry Pipe System Application `' _ �''` ,£ optimized flow characteristics are the C -%' /r major consideration, the Series LFII The Series LFII Residential Horizontal E v -� I and Recessed Horizontal Sidewall rsf4 Residential Sidewall Sprinklers(TY1334) ` :' ' should be the first choice. Sprinklers offers a laboratory approved `�=� option for designing dry pipe residen- The Series LFII Residential Sprinklers tial sprinkler systems, whereas, most are intended for use in the following residential sprinklers are laboratory Sprinkler scenarios: approved for wet systems only. p • wet and dry pipe residential sprinkler Through extensive testing, it has been Identification systems for -one- and two-family determined that the number of design dwellings and mobile homes per NFPA sprinklers (hydraulic design area) for Number (SIN) 13D the Series LFII Residential Horizontal TY1334 • wet and dry pipe residential sprinkler Sidewall Sprinklers (TY1334) need not systems for residential occupancies be increased over the number of design to and including four storiesanin sprinklers (hydraulic design area) as up height and NFPA 13R specified for wet pipe sprinkler systems, as is accustomed for density/ area • wet and dry pipe sprinkler systems sprinkler systems designed per NFPA for the residential portions of any 13. occupancy per NFPA 13 Consequently,the Series LFII Residential The recessed version of the Series Sprinklers offer the features of non-water LFII Residential Sprinklers is intended filled pipe in addition to not having to for use in areas with finished walls. increase the number of design sprin- It employs a two-piece Style 20 klers(hydraulic design area)for systems Recessed Escutcheon.The Recessed designed to NFPA 13, 13D, or 13R. Escutcheon provides 1/4 inch(6,4 mm) Non-water filled pipe will permit options of recessed adjustment or up to 1/2 inch for areas sensitive to freezing. (12,7 mm)of total adjustment from the flush mounting surface position. The NOTICE adjustment provided by the Recessed The Series LFII Residential Horizontal Sidewall Sprinklers described herein must be installed and maintained in IMPORTANT compliance with this document and the Always refer to Technical Data applicable standards of the National Fire Sheet TFP700 for the "INSTALLER Protection Association,in addition to the standards of any authorities having juris- WARNING' that provides cautions with respect to handling and instal- Failure oe o tof these devices. do so may impair the lation of sprinkler systems and performance components. Improper handling and The owner is responsible for maintaining installation can permanently damage a their fire protection system and devices sprinkler system or its components and in proper operating condition. The cause the sprinkler to fail to operate in installing contractor or sprinkler manu- a fire situation or cause it to operate facturer should be contacted with any prematurely. questions. Page 1 of 6 APRIL 2013 REV A TFP410 TFP41® Page 2 of 6 Components: 5 3 2 1 1 - Frame WRENCH I 2 - Button Assembly %:fl► O FLATS 3 - Sealing Assembly o nMAr I(� 4- Bulbo �IN��� i 5 - Compression Screw ► ��_1� 6- Deflector* TOP-OF- 6* 4 7/16"(11,1 mm) � �'��IIIIIIIIIIII 2_7/8"DIA. DEFLECTOR —1I NOMINAL *Temperature rating I MAKE IN I�•�� 1 (73,0 mm) is indicated on top 1=1:1•1 y of Deflector. I'=% _ III I CENTERLINE I " 'It IIV OF WATERWAY 7/16" �+ _ IR(II STYLE 20 (11,1 mm) 1/2"NPT RECESSED ' /-------..—_ 1-5/8" \ ESCUTCHEON END-OF- (41,3 mm) `I ESCUTCHEON DEFLECTOR 2-1/4" J PLATE SEATING BOSS —(57,2 mm) I SURFACE - FIGURE 1 , RAPID RESPONSE SERIES LFII RESIDENTIAL HORIZONTAL SIDEWALL AND RECESSED HORIZONTAL SIDEWALL SPRINKLERS(TY1334) 7/16±1/8" G, (11,1±3,2 mm) MOUNTING FACE OF WRENCH RECESS SURFACE ` SPRINKLER (END"A"USED FITTING FOR TY1334) TCLOSURE DEFOLECTOR \ FIGURE 3 1\ TY1334 W-TYPE 6 2-7/8"DIA. SPRINKLER WRENCH r—Pa� I ► (73,0 mm) �'••FIIIIII DIA. WRENCH (57,2 mm) RECESS - 7/16" (11,1 mm) p�•` /rI 07 MOUNTING .I'1 / iiiII PLATE END-OF- • DEFLECTOR [ 1/8" ' ' ' BOSS ' (3,2 mm) ' PUSH WRENCH 1-3/8"(34,9 mm) 1/2"(12,7 mm) INTO ENSURE - 1-1/8"(28,6 mm) 1/4"(6,4 mm) ENGAGEMENT ' WITH SPRINKLER FIGURE 2 - WRENCHING AREA STYLE 20 RECESSED ESCUTCHEON FIGURE 4 , ; FOR USE WITH THE RAPID RESPONSE SERIES LFII RESIDENTIAL W-TYPE 7 RECESSED HORIZONTAL SIDEWALL SPRINKLER(TY1334) SPRINKLER WRENCH TFP41O Page 3 of 6 Technical System Types Operational Sensitivity Per the UL Listing, wet pipe and dry The sprinklers are to be installed with an Data pipe systems may be utilized. Per the end-of-deflector-boss to wall distance C-UL Listing, only wet pipe systems of 1-1/4 to 6 inches. , may be utilized. In addition the top-of-deflector-to- Approvals UL Listed for use with wet pipe and dry Refer to Technical Data Sheet TFP485 ceiling distance is to be within the range pipe systems about the use of Residential Sprinklers (Tables A and B) being hydraulically in residential dry pipe systems. calculated. NSF Certified to NSF/ANSI 61 C-UL Listed for use only with wet pipe Ceiling Types Sprinkler Spacing Smooth flat horizontal,or beamed, or The minimum spacing between sprin- systemssloped, in accordance with the 2013 klers is 8 feet (2,4 m).The maximum NYC Approved under MEA 44-03-E Edition of NFPA 13D, 13R, or 13 as spacing between sprinklers cannot For details on these approvals,refer to applicable. - exceed the width of the coverage area the Design Criteria section. (Tables A and B) being hydraulically Hydraulic Design calculated(e.g.,maximum 12 feet for a Maximum Pressure (NFPA 13D and 13R) 12 ft.x 12 ft.coverage area,or 16 feet (12,1 Workingbar) For systems designed to NFPA 13D for a 16 ft.x 20 ft.coverage area.). 175 psior NFPA 13R, the minimum required Discharge Coefficient sprinkler flow rates are given in Tables g A and B as a function of temperature K=4.2 GPM/psi1/2(60,5 LPM/bar1I2) rating and the maximum allowable - coverage areas.The sprinkler flow rate Temperature Rating is the minimum required discharge 155°F(68°C)or 175°F(79°C) from- each of the total number of "design sprinklers" as specified in Finishes NFPA 13D or NFPA 13R.The number of Signal or Pure White "design sprinklers"specified in NFPA Chrome Plated 13D and 13R for wet pipe-systems is - Natural Brass to be applied when designing dry pipe Physical Characteristics systems. Frame Brass Hydraulic Design Button Copper (NFPA 13) Sealing Assembly Beryllium For systems designed to NFPA 13, Nickel w/TEFLON the number of design sprinklers is Bulb(3 mm) Glass to be the four most hydraulically Compression Screw Bronze demanding sprinklers. The minimum Deflector Copper required discharge from'each of the four sprinklers is tobethe greater of Operation the following: The glass bulb contains a fluid that • The flow rates given in Tables A and expands when exposed to heat.When B as-a function of temperature rat- the rated temperature is reached,the ing and the maximum allowable fluid expands sufficiently to shatter the coverage area glass bulb, allowing the sprinkler to • A minimum discharge of 0.1 gpm/ft2 activate and flow water. over the"design area"comprised of the four most hydraulically demand- Design ing sprinklers for actual coverage ar- eas protected by the four sprinklers Criteria The number of "design sprinklers" The TYCO RAPID RESPONSE specified in NFPA 13 for wet pipe Series LFII Residential Horizontal systems and Recessed Horizontal Sidewall designing dry pipe systems. be applied when is Sprinklers(TY1334)are UL and C-UL Dry Pipe System Water Delivery Listed for installation in accordance When using the Series LFII Residential with the following criteria. Horizontal Sidewall Sprinklers(TY1334) in dry pipe spnnkler systems,the time Residential Sprinkler Design Guide for water delivery must not exceed 15 When conditions exist that are outside seconds for the most remote operating the scope of the provided criteria,refer sprinkler. to the Residential Sprinkler Design Guide TFP490 for the manufactur- Obstruction to Water Distribution er's recommendations that may be Sprinklers are to be located in accor- acceptable to the local authority having dance with the obstruction rules of jurisdiction. NFPA 13D, 13R,and 13 as applicable for residential sprinklers as well as with the obstruction criteria described within the TYCO Technical Data Sheet TFP490. TFP41O Page'4 of 6 WET PIPE SYSTEM Max.Coverage Max. Minimum Flow and Residual Pressure'',c) , Area(a) Spacing Ordinary Temp.Rating Intermediate Temp.Rating Width x Length(d) t. 155°F(68°C) _ 175°F(79°C) Minimum Ft.x Ft. m . Flow Pressure Flow Pressure Deflector to Installation, Spacing (m x m) GPM PSI GPM PSI Ceiling Type Ft. (L/min) (bar) (L/min) (bar) , (m) 12 x 12 12 '12 8.2 12 8.2 - (3,7 x 3,7). (3,7) (45,4) (0,57) (45,4), , (0,57),- 14 x 14 14 14 11.1 16 14.5 (4,3 x 4,3) (4,3) (53,0) (0,77) (60,6) (1,00) - 16x16 16 16 14.5 16 14.5 4to , (4,9 x 4,9) (4,9) (60,6) (1,00) (60,6) (1,00) 6 inches 16 x 18 16 - 19 20.5 ,19 20.5 (4,9 x 5,5). (4,9) , (71,9) (1,41) (71,9) (1,41) , 16 x 20 16 23 30.0 23 30.0 Recessed using Style 20 (4,9 x 6,1) (4,9) (87,1) (2,07) (87,1) (2,07) Escutcheon or 8 12 x 12 12 13 9.6 13 9.6 non-recessed (2,4) (3,7 x 3,7) (3,7) (49,2) , -(0,66) , (49,2) . (0,66) per NFPA 13D, ' 13R,or 13 14x14 14 17 " 16.4 '18 - 18.4 (4,3 x 4,3) (4,3) (64,3) (1,13)' (68,1) (1,27) ' ' 16x16 16 18 18.4 18 ' 18.4 ' 6to (4,9 x 4,9) (4,9) (68,1) ' (1,27) (68,1) (1,27) 12 inches 16 x 18 16 21 , 25.0, 21 25.0 (4,9 x 5,5) (4,9) (79,5) (1,72) 179,5) . (1,72). , 16 1,72)- 16 x 20 16 26 -. 38.3. , 26,, - ; 38.3. , (4,9 x 6,1) (4,9) (98,4) (2,64) ' (98,4) (?,64) ' (a) For coverage area dimensions less than or between those indicated,use the minimum required flow for the next highest coverage area for which hydraulic design cnteria are stated. - (b) Requirement is based on minimum flow in GPM(LPM)from each spnnkler.The associated residual pressures are calculated using the nominal K- factor.Refer to Hydraulic Design under the Design Criteria section. - (c) For NFPA 13 residential applications,the greater of 0.1 gpm/ft2 over the design area or the flow in accordance with the criteria in this table must be used. (d) The Width x Length dimension refers to the Width(backwall where the spnnkler is located)times the Length(honzontal throw of sprinkler). TABLE A WET PIPE SYSTEM , SERIES LFII RESIDENTIAL HORIZONTAL AND RECESSED HORIZONTAL SIDEWALL SPRINKLERS(TY1334) NFPA 13D, 13R,AND 13 HYDRAULIC DESIGN CRITERIA • ti , • o TFP41O Page 5 of 6 DRY PIPE SYSTEM • - Max.Coveage Spacing Minimum Flow and Residual Pressure(b•0 , Area Ordinary Temp.Rating Intermediate Temp.Rating . - Width x Length(d) Ft. 155°F(68°C) 175°F(79°C) - Minimum Ft.x Ft. (m) Flow Pressure Flow Pressure Deflector to 'Installation Spacing Ceiling Type ' Ft. ' (m x m) GPM PSI GPM PSI (m) (L/min) , (bar) (L/min) ' (bar) 12 x 12 12 12 8.2 12 8.2 (3,7 x 3,7) (3,7) (45,4) (0,57) (45,4) (0,57) ,14x14 14 16 14.5 16 14.5 ' • (4,3 x 4,3) (4,3) (60,6) (1,00) (60,6) (1,00) , , 16,x 16 16 16 14.5 16 14.5 4 to (4,9 x 4,9) (4,9) (60,6) (1,00) " ' (60,6) (1,00) 6 inches 16x18 16 19 ,20.5 N/A N/A (4,9 x 5,5) (4,9) (71,9) (1,41) . -16 x 20 16 . 23 30.0 - Recessed (4,9 x 6,1)- (4,9) (87,1) (2,07) N/A N/A Escutcheon o0r 8 12 x 12 12 13 9.6 13 9.6 non-recessed (2,4) (3,7 x 3,7) (3,7) , (49,2) (0,66) (49,2) (0,66) per NFPA 13D, 13R,or 13 14x14 ' 14 18 18.4 18• 18.4 (4,3 x 4,3) (4,3) (68,1) (1,27) (68,1) (1,27) 16 x 16 16 - 18- 18.4 " 21 - , 25.0 6 to (4,9 x 4,9) (4,9)' (68,1) , (1,27) (79,5) (1,72) 12 inches 16 x 18 16 - 21 25.0 , 21 25.0 • (4,9 x 5,5) (4,9) (79,5) (1,72) . (79,5) . (1,72) , 16 x 20 16 N/A N/A N/A • N/A (4,9 x 6,1) , (4,9) , (a) For coverage area dimensions less than or between those indicated,use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated (b) Requirement is based on minimum flow in GPM(LPM)from each spnnkler.The associated residual pressures are calculated using the nominal K- ' factor.Refer to Hydraulic Design under the Design Critena section. (c) For NFPA 13 residential applications,the greater of 0.1 gpm/ft2 over the design area or the flow in accordance with the criteria in this table must be used. (d) The Width x Length dimension refers to the Width(backwall where the spnnkler is located)times the Length(horizontal throw of sprinkler). ' TABLE B DRY PIPE SYSTEM • SERIES LFII RESIDENTIAL HORIZONTAL AND RECESSED HORIZONTAL SIDEWALL SPRINKLERS(TY1334) NFPA 13D, 13R,AND 13 HYDRAULIC DESIGN CRITERIA TFP410 Page 6 of 6 Installation - Step B. After installing the Style 20 damaged by dropping,striking,wrench -Mounting Plate over the sprinkler twist/slippage, or the like, must be The TYCO RAPID RESPONSE • threads and with pipe-thread sealant replaced. Also, replace any sprinkler Series LFII Residential Horizontal applied to the pipe threads, hand-. that has a cracked bulb or that has lost and Recessed Horizontal Sidewall tighten the sprinkler into the sprinkler ,liquid from its bulb. (Ref. Installation Sprinklers(TY1334)must be installed-, • fitting: ' , ,Section.) in accordance with,this section. •, Step C. Tighten the sprinkler into the The owner is responsible for the sprinkler fitting using only the W-Type inspection,testing,and maintenance of General Instructions - 7 Recessed Sprinkler Wrench(Figure -their fire protection system and devices Do not install any bulb type sprinkler if 4).With reference to Figure 1,apply the in compliance with this document,as the bulb is cracked or there is a loss of ,W Type 7 Recessed Sprinkler Wrench_-, well as with the applicable standards of liquid from the bulb.With the sprinkler to the sprinkler wrench flats. the National Fire Protection Association• held horizontally, a small air bubble (e.g., NFPA 25), in addition to the' should be present.The diameter of the Step D. After the ceiling has been standards of any authorities.having' air bubble is approximately 1/16 inch installed or the finish coat has;been urisdiction. Contact the installing applied,slide on the Style 20 Closure ) (1,6 mm). pp contractor or sprinkler manufacturer A leak-tight 1/2 inch NPT sprinkler overthe Series LFII Residential regarding any questions. ' 9 p Sprinkler and push the Closure over the • joint should be obtained by applying a Mounting Plate until its flange comes in Automatic sprinkler systems are recom- minimum to maximum torque of 7 to 14 contact with the wall. - ' mended to be inspected,tested, and ft. lbs. (9,5 to 19,0 Nm). Higher levels maintained by a qualified Inspection of torque can distort the sprinkler Inlet " ' . Service in accordance with local with consequent leakage or impairment Care and requirements and/or national codes. of the sprinkler. , Do not attempt to !compensate Maintenance , Ordering for insufficient adjustment in an _The TYCO RAPID RESPONSE- Y Escutcheon Plate by under- or over- Series LFII Residential Horizontal Procedure tightening the Sprinkler. Re-adjust the and Recessed Horizontal Sidewall _ • . position of the sprinkler fitting to suit. ; Sprinklers(TY1334),must be maintained Contact your local distributor for and serviced in accordance with this availability. 'When,placing an order„ Series LFII Residential Horizontal section.• . , indicate the full'product name and Part Sidewall Sprinklers - Number(P/N). The Series LFII Residential Horizontal Before closing a fire protection system Sidewall Sprinklers must be installed main control valve for maintenance Sprinkler Assembly in accordance with. the following work on the fire protection system Specify: Series LFII (TY1334), K=4.2, instructions. that it controls, obtain permission to Residential Horizontal Sidewall shut down the affected fire protection Sprinkler,(specify)temperature rating,- Step 1.Install horizontal sidewall sprin- systems from the proper authorities • (specify)finish,P/N-(specify). ' klers in the horizontal position with their and notify all personnel who may be 155°F(6IPC) centerline of waterway perpendicular to affected by this action. Natural Brass P/N 51-211-1-155 the backwall and parallel to the ceiling. Absence of the outerpiece, of an Pure White(RAL9010)' - P/N 51-211-3-155 The word"TOP"on the Deflector is to Signal White(RAL9003) P/N 51-211-4-155 face towards the ceiling with the'front escutcheon, which,is used to cover Chrome Plated P/N 51-211-9-155 edge of the Deflector parallel to the a clearance hole, can delay sprinkler 175.F(79°c) ceiling. operation in a fire situation. Natural Brass P/N 51-211-1-175 Step 2. With pipe-thread sealant The owner must assure that the sprin- Pure gnlWso) Signal e(Re AL9003) P/N 51-211-3-175 P/N 51-211-4-175 applied to the pipe threads, hand klers are not used for hanging any Chrome Plated P/N 51-211-9-175 tighten the sprinkler into the sprinkler objects and that the sprinklers are only fitting. cleaned by means of gently dusting *Eastern Hemisphere sales only. with a feather duster;otherwise,non- Step 3. Tighten the sprinkler into the operation in the event of a fire or road- Recessed Escutcheon sprinkler fitting using only the W-Type vertent operation may result. Specify: Style 20 Recessed 6 Sprinkler Wrench (Figure 3). With • Escutcheon with(specify`)finish, P/N reference to Figure 1,apply the W-Type Sprinklers which are found to be (specify*). 6 Sprinkler Wrench to the wrench flats. leaking or exhibiting visible signs of corrosion must be replaced. 'Refer to Technical Data Sheet TFP770. Series LFII Residential Recessed Automatic sprinklers must never be Sprinkler Wrench Horizontal Sidewall Sprinklers painted, plated, coated, or otherwise Specify W-Type 6 Sprinkler Wrench, The Series LFII Residential Recessed altered after leaving the factory. P/N 56-000-6-387. Horizontal Sidewall Sprinklers must Modified sprinklers must be replaced. Specify W-Type 7 Sprinkler Wrench, be installed in accordance with the Sprinklers that have been exposed to P/N 56-850-4-001. following instructions. corrosive products of combustion,but Step A. Install recessed hori- have not operated,should be replaced zontal sidewall sprinklers in the hori- if they cannot be completely cleaned zontal position with their centerline by wiping the sprinkler with a cloth or of waterway perpendicular to the by brushing it with a soft bristle brush. backwall and parallel to the ceiling.The Care must be exercised to avoid word"TOP"on the Deflector is to face damage to the sprinklers - before, towards the ceiling. during,and after installation.Sprinklers GLOBAL HEADQUARTERS 11400 Pennbrook Parkway,Lansdale,PA 19446 Telephone+1-215-362-0700 Copyright©2013 Tyco Fire Products,LP. All rights reserved. tliCEI TEFLON is trademark of The DuPont Corporation. Worldwidetg,io Contacts www eco-fire.com Fire 'L rotection Pro(.i' Cts Series TY-FRB, 5.6 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General NOTICE _.-- __--x .-;s The TYCO Series TY-FRB Sprinklers ale"tt—;4,,d ''`-°'_ Description described herein must be installed and _ -. maintained in compliance with this doc- The TYCO Series TY-FRB,5.6 K-factor, ument, as well as with the applicable /1', 4 Upright(TY313)and Pendent(TY323) standards of the National Fire Protec- .i .:,:k Sprinklers described in this data sheet tion Association,in addition to the stan- ^ ,` z. Atl` are quick response,standard coverage, dards of any other authorities having .' :r,f LT '' decorative 3 mm glass bulb-type spray jurisdiction.Failure to do so may impair `4-',,'',', ' ' sprinklers designed for use in light or 7.7,-7,1::;- �' P 9 9 the performance of these devices. 4.V __ ,,1 ordinary hazard,commercial occupan- cies such as banks,hotels,and shop- The owner is responsible for maintain- ping malls. ing their fire protection system and = - •- 7'- devices in proper operating condition. The recessed version of the Series TY The installing contractor or sprinkler FRB Pendent Sprinkler,where applica- manufacturer should be contacted with --�, ble, is intended for use in areas with a any questions. .,-''" ;. .` ` finished ceiling.This recessed pendent i sprinkler uses one of the following: s "4 Sprinkler - -- = .. • A two-piece Style 15 Recessed p 1 ' - Escutcheon'with recessed adjust- (- the Identification 6 `flush pendent position. Number (SIN) • A two-piece Style 20 Recessed `\ \,-,ti.-',;i-��j Escutcheon with recessed adjust- TY313 Upright 5.6K,1/2"NPT d ment u to 1/2 inch (12,7 mm)from TY323 Pendent 5.6K,1/2"NPT ..i.4.-t, the flush pendent position. The adjustment provided by the Technical Recessed Escutcheon reduces the Temperature Rating accuracy to which the fixed pipe drops Data 135°F(57°C) to the sprinklers must be cut. 155°F(68°C) Intermediate level versions of Series Approvals 175°F(79°C) TY-FRB Sprinklers are described in UL and C-UL Listed 286°F(941 3°C) Y ) Technical Data Sheet TFP357. Sprin- FM,LPCB,and VdS Approved kler guards and shields are described CE Certified Finishes in Technical Data Sheet TFP780. Sprinklers with Polyester Finish are UL Sprinkler:Refer to Table A and C-UL Listed as Corrosion-Resis- Recessed Escutcheon:White Coated,' tant Sprinklers. Chrome Plated,or Brass Plated Maximum Working Pressure Physical Characteristics 175 psi(12.1 bar) Frame Bronze ' 250 psi(17.2 bar)* Button Brass/Copper *The maximum working pressure of 250 psi Sealing Assembly Stainless IMPORTANT (17.2 bar)only applies to the listing by Un- Steel w/TEFLON Always refer to Technical Data derwriters Laboratories,Inc.(UL). Bulb Glass Sheet TFP700 for the "INSTALLER Discharge Coefficient Compression Screw Bronze WARNING"that provides cautions K=5.6 GPM/psi1I2(80,6 LPM/bar1I2) Deflector Bronze with respect to handling and instal- lation of sprinkler systems and com- ponents.,Improper handling and installation can permanently dam- age a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause ' it to operate prematurely. Page 1 of 4 FEBRUARY 2014 TFP172 TPP172 Page 2 of 4 Components: *Temperature rating is **Pipe thread connections per ISO 7-1 1 - Frame 4 - Bulb indicated on Deflector. can be provided on special request. 2 - Button 5 - Compression STYLE 15 or 20 3 - Sealing Screw ESCUTCHEON PLATE 1/2" 7/16"(11,1 mm) RECESSED Assembly 6 - Deflector* DEFLECTOR* SEATING SURFACE NPT** NOMINAL MAKE-IN ESCUTCHEON P/77-11.Eim:\ .97/-rf— -11-fid -%, ---\ ---_----- 5 'c' (11,17/1mm) IN } '��1 c 4 I NOMINAL 2" I� /ea MAKE-IN (50,8 mm) 1 ;- EMIN 2 1 Y, lir p► " ` 2" 1-3/8" 'kr 3 �! (50,8 mm) (34,9 mm) WRENCH ___ Pr 0 / FLATS 1/2 . — 1 i ....--,...,-.1.:---.----t "NPT** DEFLECTOR* 2-7/8°(73,0 mm)DIA. CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT FIGURE 1 SERIES TY-FRB UPRIGHT(TY313)AND PENDENT(TY323)SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT, QUICK RESPONSE L, Operation Installation The glass bulb contains a fluid which The TYCO Series TY-FRB,5.6 K-factor, WRENCH RECESS expands when exposed to heat.When Upright(TY313)and Pendent(TY323) (USE ONLY the rated temperature is reached,the Sprinklers must be installed in accor- END"A") fluid expands sufficiently to shatter the dance with this section. glass bulb, allowing the sprinkler to General Instructions FIGURE 2 activate and water to flow. Do not install any bulb-type sprinkler if W-TYPE 6 the bulb is cracked or there is a loss SPRINKLER WRENCH Designof liquid from the bulb.With the sprin- kler held horizontally,a small air WRENCH bub- Criteria ble should be present. The diameter of the air bubble is approximately 1/16 RECESS The TYCO Series TY-FRB,5.6 K-factor, inch(1,6 mm)for the 135°F(57°C)and Upright(TY313)and Pendent(TY323) 3/32 inch(2,4 mm)for the 286°F(141°C) Sprinklers are intended for fire protec- temperature ratings. L/ -� tion systems designed in accordance A leak-tight 1/2 inch NPT sprinkler joint with the standard installation rules rec- ognizedshould be obtained byapplying a Appo by the applicable Listing or o Approval agency(such as, UL Listing min- imum to maximum torque of 7 to 14 ` 4 is based on the requirements of NFPA ft. lbs. (9,5 to 19,0 Nm). Higher levels %.�� 13, and FM Approval is based on the of torque can distort the sprinkler Inlet requirements of FM's Loss Prevention with consequent leakage or impairment PUSH WRENCH Data Sheets).Only the Style 15 or Style of the sprinkler. IN TO ENSURE 20 Recessed Escutcheon is to be used Do not attempt to compensate for ENGAGEMENT for recessed pendent installations. ,' insufficient adjustment in the Escutch- WITH SPRINKLER eon Plate by under-or over-tightening WRENCHING AREA ' the sprinkler. Re-adjust the position of FIGURE 3the sprinkler fitting to suit. W-TYPE 7 RECESSED ' SPRINKLER WRENCH Upright and Pendent Sprinklers The Series TY-FRB Upright and Pen- dent Sprinklers must be installed in accordance with the following instructions. Step 1.Install Pendent sprinklers in the pendent position. Install upright sprin- klers in the upright position. Step 2. With pipe-thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. TFP172 Page 3 of 4 Step 3.Tighten the sprinkler into the 2-7/8"DIA. sprinkler fitting using only the W-Type - (73,0 mm) 6 Sprinkler Wrench(Figure 2).With ref- erence to Figure 1,apply the W-Type 6 2-1/4"DIA. _ Sprinkler Wrench to the wrench flats. FACE OF ~ (57,2 mm) Torque sprinklers 7 to 14 ft.-lbs.(9,5 to SPRINKLER 19,0 Nm). FITTING 5/8"(15,9 mm) Recessed Pendent Sprinklers i \ NI FLUSH The Series TY-FRB Recessed Pendent 3/8±5/16" - - IF' Sprinklers must be installed in accor- (9,5±7,9 mm) -% i 1V '. dance with the following instructions. - r I J� Step A.After installing the Style 15 or I MOUNTING '•-' 1/8" Style 20 Mounting Plate over the sprin- SURFACE ' (3,2 mm) kler threads, and with pipe-thread — sealant applied to the pipe threads, CLOSURE SERIES MOUNTING 1-3/8"(34,9 mm) hand-tighten the sprinkler into the TY-FRB PLATE sprinkler fitting. 3/4"(19,1 mm) FIGURE 4 Step B.Tighten the sprinkler into the SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY(TY323) sprinkler fitting using only the W-Type WITH TWO PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 15 7 Recessed Sprinkler Wrench (Figure -RECESSED ESCUTCHEON 3).With reference to Figure 1,apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Torque - 2-7/8"DIA. - sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 (73,0 mm) Nm). FACE OF Step C.After ceiling installation and fin- SPRINKLER r 2 ishing,slide on the Style 15 or Style 20 FITTING (57 2 mm) Closure over the Series TY-FRB Sprin- 5/16±1/4" kler and push the Closure over the (7,9±6,4 mm) 1/2"(12,7 mm) Mounting Plate until its flange comes in _ - FLUSH contact with the ceiling. 1II, . ,7 Care and t 1 1/8" Maintenance SURFACE � MO - (3,2 mm) The TYCO Series TY-FRB,5.6 K-factor, CLOSURE SERIES MOUNTING 1-3/8"(34 ,9 mm) Upright(TY313)and Pendent(TY323) Sprinklers must be maintained and ser- TY-FRB PLATE 7/8"(22,2 mm) viced in accordance with this section. - - FIGURE 5 Before closing a fire protection system SERIES TY-FRB RECESSED.PENDENT SPRINKLER ASSEMBLY(TY323) main control valve for maintenance WITH TWO PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 work on the fire protection systemRECESSED ESCUTCHEON that it controls, obtain permission to . shut down the affected fire protection Modified sprinklers must be replaced. standards of any other authorities hav- systems from the proper authorities Sprinklers that have been exposed to ing jurisdiction. Contact the installing and notify all personnel who may be corrosive products of combustion,,but contractor or sprinkler manufacturer affected by this action. have not operated,should be replaced regarding any questions. Absence of the outer piece of an if they cannot be completely cleaned Automatic sprinkler systems are rec- escutcheon, which is used to cover by wiping the sprinkler with a cloth or ommended to be inspected, tested, a clearance hole, can delay sprinkler by brushing it with a soft bristle brush. and maintained by a qualified Inspec- operation in a fire situation. Care must be exercised to avoid dam- tion Service in accordance with local The owner must assure that the sprin- age to the sprinklers before,during,and requirements and/or national codes. klers are not used for hanging any after installation.Sprinklers damaged objects and that the sprinklers are only by dropping, striking, wrench twist/ cleaned by means of gently dusting slippage,or the like,must be replaced. with a feather duster;otherwise, non- Also, replace any sprinkler that has a operation in the event of a fire or inad- cracked bulb or that has lost liquid from vertent operation may result. its bulb.(Ref.Installation Section.) Sprinklers which are found to be leak- The owner is responsible for the ing or exhibiting visible signs of corro- inspection,testing,and maintenance of sion must be replaced. their fire protection system and devices in compliance with this document, as Automatic sprinklers must never be well as with the applicable standards painted, plated, coated, or other- of the National Fire Protection Associa- wise altered after leaving the factory. tion (e.g., NFPA 25), in addition to the TFP172 Page 4 of 4 P/N* 77 - XXX - X - XXX SPRINKLER TEMPERATURE FINISH RATINGS SIN 1 NATURAL BRASS 135 135°F(57°C) 370 5.6K UPRIGHT(1/2"NPT) TY313 3 PURE WHITE(RAL9010°° 155 155°F(68°C) POLYESTER 371 5.6K PENDENT(112"NPT) TY323 4 SIGNAL WHITE(RAL9003) 175 175°F(79°C) POLYESTER •Use suffix"I"for ISO 7-1 connection, 9 CHROME PLATED 200 200°F(93°C) for example,77-370-4-175-I ••Eastern Hemisphere sales only 286 286°F(141°C) TABLE A SERIES TY-FRB UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION Limited Ordering Warranty Procedure For warranty terms and conditions,visit Contact your local distributor for avail- www.tyco-flre.com. ability.When placing an order,indicate the full product name and Part Num- ber(P/N). Sprinkler Assemblies with NPT Thread Connections Specify:Series TY-FRB Upright or Pen- dent(specify)Sprinkler,SIN (specify), K=5.6,Quick Response,(specify)tem- perature rating, (specify) finish, P/N (specify,refer to Table A). Recessed Escutcheon Specify:Style 15 Recessed Escutcheon • with(specify")finish, P/N(specify") Specify: Style 20 Recessed Escutch- eon with(specify*)finish,P/N(specify*) Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 • GLOBAL HEADQUARTERS 11400 Pennbrook Parkway,Lansdale,PA 19446 Telephone+1-215-362-0700 Copyright©2014 Tyco Fire Products,LP. All rights reserved. 'tug= TEFLON Is trademark of The DuPont Corporation °`il Fire Protection Products tqca I Fire & Building „ Products - - rapid response' HOME FIRE SPRINKLER SYSTEM Technical Services:Tel:(800)381-9312/Fax:(800)791-5500 Y BlazeMaster ® r r : .. CPVC Fire Sprinkler-Pipe &-Fittings Submittal Sheet _, General . ,. . = Description Technical- ,, ., Data: . ' Tyco® CPVC Pipe and Fittings pro- .„, '; �_,. duced by Tyco Fire & Building Prod- v ucts (TFBP)ate designed exclusively Sizes for use in wet pipe automatic fire sprin- 3/4”to 3 - 1 kler systems. The Tyco CPVC Pipe Maximum Pressure' ' { .• and Fittings are produced from Blaze- 175 si Working "` Master@ CPVC compound that is a p _• t � ` specially developed thermoplastic Approvals '_ compound composed of post chlorin- UL, FM, C-UL, NSF,LPCB, MEA,and ' rr',a ated polyvinyl chloride (CPVC) resin the City of Los Angeles. (Refer to In- ;:'$ and state of the art additives. Tyco stallation Handbook IH-1900 dated } �` CPVC Pipe and Fittings are easier to June 2008 for exact listing/approval -= _ , 1_ ',;: ;mss - install than traditional steel pipe sys- information.) , tems, and at the same time, provide Manufacture Source ' superior heat resistance and strength U.S.A. . as compared to traditional CPVC and PVC piping materials used in the Material , , plumbing trade.Various adapters are . Pipe:ASTM F442,SDR 13.5 available to connect CPVC pipe to me- ' tallic piping. All female pipe thread •'Fittings: ASTM F438 (Sch. 40) and , adapters have brass inserts for dura- ASTM F439(Sch.80),ASTM F1970 bility. Grooved adapters connect di- Color • rectly to grooved end valves and me- Orange , -, tallic pipe, with flexible grooved end ' couplings. • NOTICE , Tyco® CPVC Pipe and Fittings pro- ,''_u, , • _ . ,, , f . ' duced with BlazeMaster®CPVC corn- -- ._ .-__ • 1, pound described herein must be in- ' stalled and maintained in compliance ,, with this document and with the appli- - cable standards of the National Fire Protection Association, in addition to . , the standards of any authorities having , jurisdiction. Failure to do so may im- pair the performance of these devices. The owner is responsible for maintain- ,' ' ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. BlazeMastere is a registered trademark of The Lubrizol Corporation Page 1 of 2• - • - • • . • JUNE, 2008, , .. - - „ , - TFP1915 , Page 2 of 2 TFP1915 Installation Limited Tyco® CPVC Pipe and Fittings pro- Warranty duced by Tyco Fire & Building Prod - ' ucts (TFBP) are to be installed in' Products manufactured by Tyco Fire& accordance with Installation Hand- Building Products (TFBP) are war- book IH-1900 dated June 2008. ranted solely to the original Buyer for ten(10)years against defects in mate- Care and rial and workmanship when paid for and properly installed and maintained Maintenance under normal use and service. This warranty will expire ten (10) years from date of shipment by TFBP. No The owner is responsible for the in- warranty is given for products or corn- spection,testing, and maintenance of ponents manufactured by companies their fire protection system and de- not affiliated by ownership-with TFBP ` - ' - - . vices in compliance with this docu- or for products and components which ment, as well as with the applicable have been subject to misuse,improper standards of the National Fire Protec- installation, corrosion, or which have tion Association (e.g., NFPA 25), in not been installed, maintained, modi- addition to the standards of any fled or repaired in accordance with ap- authority having jurisdiction. The in- plicable Standards of the National Fire . stalling contractor or product manufac- Protection Association, and/or the . turer should be contacted relative to standards of any other Authorities ' any questions. Having Jurisdiction. Materials found • - Automatic sprinkler systems should be by TFBP to be defective shall be either ' inspected,tested,and maintained by a repaired or replaced, at TFBP's,sole - qualified Inspection Service in accord- option. TFBP neither assumes, nor ance with local requirements and/or authorizes any person to assume for it, national codes. any other obligation in connection with ' the sale of products or parts of prod- NOTICE ucts.TFBP shall not be responsible for sprinkler system design errors or inac- • Before closing a fire protection system curate or incomplete information sup- control valve for inspection or mainte- plied by Buyer or Buyer's repre- sentativesnance work on the fire protection sys- . , tem that it controls,permission to shut In no event shall TFBP be liable, in • down the affected fire protection sys- contract, tort, strict liability,or under , . tern must first be obtained from the any other legal theory; for incidental, , proper authorities and all personnel indirect,special or consequential da - who may be affected by this action ages,including but not limited tom labor must be notified. charges, regardless of whether TFBP was informed about the possibility of After placing a fire protection system such damages, and in no event shall in service,notify the proper authorities TFBP's liability exceed an amount and advise those responsible formoni- equal to the sales price. toring proprietary and/or central sta- The foregoing warranty is made in lieu • tion alarms. of any and all other warranties. ex- press or implied. including warranties of merchantability and fitness for a par- , ticular purpose. This limited warranty sets forth the ex- clusive remedy for claims based on ' failure of or defect in products,materi- als or components,whether the claim ' ' is made in contract, tort, strict liability .,. _ or any other legal theory. • ' This warranty will apply to the full ex- tent permitted by law.The invalidity,in , , , , , whole or part, of any portion of this , - , ', - warranty will not affect the remainder. „ • , . . , ©2008 TYCO FIRE&BUILDING PRODUCTS,451 North Cannon Avenue,Lansdale,Pennsylvania 19446. tqcci IF & Building- - - Products aet - rapid response HOME FIRE SPRINKLER SYSTEM Technical Services:Tel:(800)381-9312/Fax:(800)791-5500 ' , Figure 513D (13D) and 513D/R (13D/f1) Riser Manifolds 1, 1-1/2, and 2 Inch (DN25, DN4O, and DN5O) For NFPA 13D/13R Residential Sprinkler Systems' General Technical _ Description - Data , 2` _ The Riser Manifolds described in this Approvals `, - '-f-t: technical data sheet provide the nec- The Figure 513D (13D) and 513D/R 7; essary waterflow alarm, pressure " (13D/R) Riser Manifolds with a cover ` gauge,and drain equipment in a single tamper switch for the waterflow alarm assembly for use in NFPA 13D or 13R switch are UL Listed, ULC Listed, and residential sprinkler systems as fol- FM Approved. x+0... " .. lows: The Figure 513D (13D) and 513D/R -- NFPA 13D (13D/R) Riser Manifolds without a • Figure 513D(13D) cover tamper switch for thewaterflow - - 1 Inch(DN25) alarm switch are UL Listed.and FM - l_ Female Thread x Female Thread Approved. NFPA 13D/13R Maximum Working Pressure 175 psi(12,1 bar) line prior to performing the alarm test. • Figure 513D/R(13D/R) Assembly The second option is to install an In- 1-1/2 Inch (DN40) - The manifold body of the Figure 513 is spector's Test Connection down- Male Thread x Female Thread ductile iron, whereas the manifold stream of the Waterflow Alarm Switch. Male Thread x Male Thread body of the Figure 13 is cast iron.The (3) Never remove any piping compo- • Figure 513D/R(13D/R) two assemblies are completely inter- nent nor correct or modify any piping 2 Inch(DN50) changeable in function, application, deficiencies without first depressuriz- Groove x Groove . and end-to-end laying length. ing and draining the system. Male Thread x Groove Finish , Step 1. Install the manifold body with The variety of sizes and end connec- Red painted. the flow arrow pointing in the down- tions allow cost effective and easy stream position using threaded con- transition to check valves, controlInections and/or listed mechanical valves, and system piping. The Riser nstallation grooved connections,as applicable. Manifolds may be installed in either the The Riser Manifolds may be installed Step 2. Connect the drain line, and horizontal(flow switch on top)or verti- in either the horizontal(flow switch on then close the drain valve. cal(flow going up). top) or vertical (flow going up). The inlet of the Riser Manifold'may be di- Step 3. Refer to Figure 4 for wiring WARNING rectly connected to a shut-off control guidance. All wiring must be per- The Riser Manifolds described herein valve. formed in accordance with the Author- must be installed and maintained in ity Having Jurisdiction and/or the Na- compliance with this document, as NOTES tional Electrical Code. well as with the applicable standards (1) Where applicable pipe thread Step 4.Place the system in service by of the National Fire Protection Asso- • sealant is to be applied sparingly. Use filling the system with water.When fill- ciation, in addition to the standards of of a non-hardening pipe thread sealant ing the system,partially open the con- any other authorities having,jurisdic- is recommended. trol valve to slowly fill the system. Fill- tion.Failure to do so may impair the ing the system slowly will help avoid performance of these devices. (2) Provisions for an alarm test flow damaging the waterflow alarm switch. The owner is responsible for maintain- must be made. The alarm test flow is ing their fire protection system and de- to be through an orifice having a flow After the system is fully pressurized, vices in proper operating condition. capacity equal to or smaller than the completely open the control valve. smallest orifice sprinkler in the system. The installing contractor or sprinkler One of two options can be considered. Step 5. Secure all supply valves manufacturer should be contacted The first option is to temporarily install open. , with any questions. a test orifice in the outlet of the drain Page 1 of 6 APRIL, 2006 TFP960 Page 2 of 6 TFP96O NO DESCRIPTION QTY P/N EI/6 1 1 1"Manifold Body, 3-1/2" Female x Female NPT... 1 N/A (88,9 mm) 2 Waterflow Alarm Switch J VSR-SF modified with Paddle,UUFM.. ..1 971-096-01 VSR-SF modified with Paddle and Cover Tamper Switch,ULC/FM . .... 1 976-519-01 3 200 Pr kPa ' Water Pressure Gauge .. 1 2343 3 .1111 2 NOTES: / 1. Approximate weight,7 5 lbs.(3,4 kg) 1.' Waterflow 2. ULC Listed Manifolds are equipped with Cover Tamper Switches installed internal=• 9-3/4" to the Waterflow Alarm Switches. (247,7 mm) I 3. CH Common Hardware ill 3-5/8" 2-7/8" (92,1 mm) NM, ., 1 (73,0 mm) `I 'll^°I' . � , 3/4"NPT Drain Valve 4-1/2" (Normally Closed) (114,3 mm) 10" (254,0 mm) FIGURE 1 1 INCH(DN25)RISER MANIFOLD ASSEMBLY AND DIMENSIONS NO. DESCRIPTION QTY. P/N t �, • 1 1-1/2"Manifold Body, 3-1/2" ( h Male x Female NPT 1 N/A (88,9 mm) Male x Male NPT 1 N/A +I r t 2 Waterflow Alarm Snitch' ....4u VSR-SF modified with Paddle,UUFM.. ...... 1 971-096-00 VSR-SF modified with Paddle and Cover Tamper Switch,ULC/FM 1 976-519-02 3 300 psi/2000 kPa 3 Mill/ 2 Water Pressure Gauge ..1 2341 NOTES: Waterflow III 1 1. Approximate weight,8 7 lbs (3,9 kg). I ♦ ME 2. ULC Listed Manifolds are equipped with Cover Tamper Switches installed internal 11-3/8" ,- ���I to the Waterflow Alarm Switches. (288,9 mm) I^I 3. CH Common Hardware 1 . - 4-1/2" 5-3/8" (114,3 " (136,5 mm) _II_, - ,I' II�IL�I� 1" NPT Drain Valve IIS 2-1/8" (Normally Closed) (54,0 mm) 10"(254,0 mm) - Male x Female NPT Manifold 11-1/8"(282,6 mm) Male x Male NPT - Mandold FIGURE 2 1-1/2 INCH(DN40)RISER MANIFOLD ASSEMBLY AND DIMENSIONS TFP960 Page 3 of 6 NO. DESCRIPTION QTY P/N 1 2"Manifold Body, 3-1/2" Groove x Groove 1 N/A (88,9 mm) Male NPT x Groove - 1 N/A 2 Water'low Alarm Switch —14 'P , VSC with Paddle, UUFM 1 976-357-01 ' VSC with Paddle and Cover Tamper Switch, ' ULC/FM 1 976-520-01 3 300 psi/2000 kPa 3 2 Water Pressure Gauge ..1 2341 / Optionally G NOTES: 1 Watertlow ,.' Ma evNPTr 1. Approximate weight,11.0 lbs.(5,0 kg) 111 41111 Supply End Illell Connection 2. ULC Listed Manifolds are equipped with Cover Tamper Switches installed internal - 12" - I • to the Waterflow Alarm Switches (304,8 mm) 3. CH:Common Hardware RI 4-1/2" 5-7/16" - (114,3 mm) . i(138,1 mm)' 'II II ill 1" NPT FIGURE 3, Drain Valve _ 2-1/4" (Normally Closed) (57,2 mm) 2 INCH(DN50)RISER MANIFOLD ASSEMBLY AND DIMENSIONS - 13"(330,2 mm) - Groove x Groove, ' Male NPT x Groove ' result in operation of the associated recorded for the system when it was Care and alarms. Consequently, notification first installed. must be given to the owner and the fire Maintenance department, central station, or other Alarm Test Procedure With A Test signal station to which the alarms are Orifice(See Installation Note 2) The following inspection procedure connected, and notification must be must be performed as indicated,in ad- given to the building occupants.' Step 1. Temporarily install a test ori- sdition to any specific requirements office in the drain line outlet. the NFPA, and any impairment must Before closing a fire protection system be immediately corrected. control valve for inspection or mainte- Step 2. Fully open the drain valve. nance work on the fire protection sys- Make certain that drainage water will The owner is responsible for the in- tern that it controls,permission to shut not cause any damage or injury. stheirtion,fia testing, and maintenance ion system and de- down the effected fire protection sys- Step 3.Verify operation of the associ- P Ytern must first be obtained from the ated alarms. vices in compliance with this docu- proper authorities and all personnel ment, as well as with the applicable who may be affected by this action Step 3.Close the drain valve. standards of the National Fire Protec- must be notified. Step 4. Remove the test orifice from tion Association (e.g., NFPA 25), in After placinga fireprotection system the drain line outlet. addition to the standards of any y authority having jurisdiction. The in- in service,notify the proper authorities stalling contractor orproduct manufac- and advise those responsible for moni- Alarm Test Procedure With An turer should be contacted relative to toring proprietary, and/or central sta- Inspector's Test Connection(See any questions. tion alarms. Installation Note 2) It is recommended that automatic Flow Test Procedure Step 1.Fully open the Inspector's Test sprinkler systems be inspected, Connection Valve. Make certain that tested, and maintained by a qualified Step 1. Fully open the drain valve. drainage water will not cause any dam- Inspection Service in accordance with Make certain that drainage water will age or injury. local requirements and/or national not cause any damage or injury. Step 2.Verify operation of the associ- codes. Step 2.Verify that the residual (flow- ated alarms. NOTES ing) pressure indicated by the pres- Step 3. Close the Inspector's Test No attempt is to be made to repair any sure gauge,is no less that originally Connection Valve. Riser Manifold component in the field. recorded for the system when it was Only the pressure gauge or waterflow first installed. alarm switch can be replaced. If any Step 3.Close the drain valve. other problems are encountered the Step 4.Verify that the static(not flow- entire riser manifold must be replaced. ing) pressure indicated by the pres- The flow and alarm test procedure will sure gauge is no less that originally Page 4 of 6 TFP96O SWITCH TERMINAL CONNECTIONS UNINSULATED CLAMPING SEVERED LOOPED SECTION CAUTION: PLATE STRIPPED SINGLE An uninsulated section of a TERMINAL ENDS CONDUCTOR single conductor is not `\ SEPARATE permitted to be looped around CONDUCTORS CLAMPING the terminal and serve as two e'""' , PLATE separate connections.The TERMINAL wire must be severed to serve ' INCOMING `\� as two separate connections, ' `� oft thereby prorine tion intheevent of the connection supervision the event that the wire becomes dislodged from the terminal. OUTGOING IMPROPER CONNECTION METHOD PROPER CONNECTION METHOD WATERFLOW SWITCH TYPICAL ELECTRICA CONNECTIONS CONTACTS ... ..... SPDT(Form C) LOCAL END OF LINE RESISTOR CONTACT RATING ... 5A @ 125 VAC SIGNAL 2.5A @ 30 VDC DEVICE NC NO JA NC L 2.5A NO• / NCM COM COM CONTROL POWER PANEL NO FLOW NON-SUPERVISED STYLE B/CLASS B CONDITION CIRCUIT SUPERVISED CIRCUIT (SEE NOTE) NOTE: For supervised circuits,see"Switch Terminal Connections"above.The Waterflow Alarm Switch has two switches,one can be used to operate a central station,proprietary or remove signaling unit,while the other contact is used to operate a local audible or visual annunciator. COVER TAMPER SWITCH(ULC ASSEMBLIES ONLY) CONTACTS SPDT(Form C) CONTACT RATING .... 3A @ 250 VAC 5A @ 125 VAC 1mA@ 5 VDC mm. NO 4\ • NC COM CONTACTS SHOWN WITH COVER IN PLACE FIGURE 4 WIRING GUIDANCE TFP960 Page 5 of 6 Limited Ordering Warranty Information Products manufactured by Tyco Fire& Riser Manifold: Building Products (TFBP) are war- Specify;Size(specify),Figure(specify ranted solely to the original Buyer for 513D or 513D/R, (specify connection ten(10)years against defects in mate- type inlet x outlet) Riser Manifold rial and workmanship when paid for (specify-without or with)a cover tam- and properly installed and maintained per switch for the waterflow alarm under normal use and service. This switch, P/N (specify). warranty will expire ten (10) years from date of shipment by TFBP. No NOTES warranty is given for products or corn- Orders for Figure 513D or 513D/R may ponents manufactured by companies be filled with a Figure 13D or 13D/R, not affiliated by ownership with TFBP respectively. The two assemblies are or for products and components which completely interchangeable in func- have been subject to misuse,improper tion, application, and end-to-end lay- installation, corrosion, or which have ing length. not been installed, maintained, modi- if a ULC Listing is required, the Riser fled or repaired in accordance with ap- Manifold must be ordered with a cover plicable Standards of the National Fire tamper switch for the waterflow alarm Protection Association, and/or the switch. standards of any other Authorities Having Jurisdiction. Materials found by TFBP to be defective shall be either UL/ULC/FM Assemblies repaired or replaced, at TFBP's sole With Cover Tamper Switch option. TFBP neither assumes, nor 1 Inch(DN25) authorizes any person to assume for it, FT x FT P/N 4085 anyother obligation in connection with 1-1/2 Inch(DN4o) g MT x FT P/N 4088 the sale of products or parts of prod- 1-1/2 Inch(DN40) ucts.TFBP shall not be responsible for MT x MT P/N 4089 sprinkler system design errors or inac- 2 Inch(DN50) curate or incomplete information sup- 2G lncn x(DG N5o) P/N 4093 ' plied by Buyer Y or Buyer's re pre- MT x G P/N 4094 sentatives. In no event shall TFBP be liable, in UL/FM Assemblies contract, tort, strict liability or under Without Cover Tamper Switch anyother legal theory, for incidental, 1 Inch(DN25) g FT x FT P/N 4047 indirect,special or consequential dam- 1-1/2 Inch(DN40) ages,including but not limited to labor MT x FT P/N 4057 charges, regardless of whether TFBP 1-1/2 Inch(DN40) was informed about the possibility ofMT P/N 4058 such damages, and in no event shall 2 InchMT(DxN5o) g G x G P/N 4059 TFBP's liability exceed an amount 2lnch(DN50) equal to the sales price. MT x G P/N 4064 The foregoing warranty is made in lieu of any and all other warranties. ex- Replacement Parts: press or implied. including warranties Specify:(description)for use with Fig- of merchantability and fitness fora par- ure 513D, 513D/R, 13D, or 13D/R ticular purpose. Riser Manifold, P/N (Ref. Figure 1, 2 This limited warranty sets forth the ex- or 2,as applicable). clusive remedy for claims based on failure of or defect in products,materi- als or components,whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex- tent permitted by law.The invalidity,in whole or part, of any portion of this warranty will not affect the remainder. Page'6 of 6 TFP96O • • • ' • • • . • I - • TYCO FIRE&BUILDING PRODUCTS,451 North Cannon Avenue,Lansdale,Pennsylvania 19446 (1 w`1 LtTT,Atarms by Honeywell MS-92000DLS Rev.3 Battery Calculation Secondary Power Source Requirements Standby Current(amps) Secondary Alarm Current(amps) Device Type Qty Current Draw Total Qty Current Draw Total Main Circuit Board 1 x 0.145000 =, 0 145000 1 x 0.275000 = 0.275000 XRM-24B 0 ' x 0.000000 = 0 x 0.000000 = 4XTMF 0 x 0 005000 = 0 x 0.011000 = IPDACT-2 0 `x 0.093000 = 0 x 0.136000 _ IPDACT-2UD 0 x 0.098000 = 0 x 0.155000 = ECC-FFT 0 x 0.120000 = 0 x 0.230000 = ANN-BUS Devices ANN-80(-W) 0 x 0.015000 = 0 x 0.040000 = ANN-LED 0 x 0.028000 = 0 x 0.068000 = ANN-RLED 0 x 0.028000 = 0 x 0.068000 = ANN-RLY 0 x 0.015000 = 0 x 0.075000 = ANN-I/O 0 x 0.035000 = 0 x 0.200000 -_ ANN-S/PG 0 x 0.045000 = 0 x 0.045000 = ANN-LC 0 x 0.150000 = 0 x 0.150000 = ACS Annunciators ACM-8RF 0 x 0.030000 = 0 x 0.158000 = ACM-16ATF • 0 x 0.040000 = 0 x 0.056000 = ACM-32AF 0 x 0.040000 = 0 x 0.056000 = AEM-16ATF 0 x 0.002000 = 0 x 0.018000 = AEM-32AF 0 x 0.002000 = 0 x 0.018000 = AFM-16ATF 0 x 0.040000 = 0 x 0.056000 = AFM-32AF 0 x 0.040000 = 0 x 0.056000 = AFM-16AF 0 x 0.025000 = 0 x 0.065000 = LDM-32F 0 x 0.040000 = 0 x 0.056000 = LDM-E32F 0 x 0.002000 = 0 x 0.018000 = LCD-80F 0 x 0.025000 = 0 x 0.064000 = Addressable Devices BEAM355 0 x 0.002000 = BEAM355S 0 x 0.002000 = . BEAM1224 0 x 0.017000 = CP355 0 x 0.000300 = SD355 25 x 0.000300 = 0.007500 ' . SD355T 0 x 0.000300 = AD355 0 x 0.000300 = H355 30 x 0.000300 = 0.009000 H355R 0 x 0.000300 = H355HT 0 x 0.000300 = D350P 0 x 0.000300 = D35ORP 0 x 0.000300 = -1350PL 0 x 0.000300 = • ' D35ORPL 0 x 0.000300 = D355PL 0 x 0.000300 = MMF-300 0 x 0.000400 = MMF-300-10 0 x 0.003500 = . MDF-300 0 x 0.000750 = MMF-301 0 x 0.000375 = MMF-302 0 x 0.000270 = - MMF-302-6 0 x 0.002000 BG-12LX 7 x 0.000300 = 0.002100 CMF-300 0 x 0.000390 = - CMF-300-6 0 x 0.002250 = CRF-300 0 x 0.000270 = CRF-300-6 0 x 0.001450 = CDRM-300 0 x 0.001300 = • 1300 0 x 0.000400 = ' ISO-6 0 x 0.002700 = . . ` B501 BH-2 0 x 0.001000 = • • 8501 BHT-2 0 x 0.001000 B224RB 0 x 0.000500 = B224B1 0 x 0.000450 = • Fire-Lite Alarms Page 1 8/6/2015 W-GATE 0 ixi 0.024000 =1 Maximum alarm draw for all Addressable devices > 0.400000 EOLR-1 0 x 1 0.020000 =1 0 x 0.020000 = FCPS (Remote Sync) 0 x' 0.021700 = Resectable Power 4-Wire Smoke Detectors 0 l xi 0.000000 = J 0 x 0.000000 = Auxiliary Power CMF-300(Aux. Power) 0 x 0.001700 = 0 x 0.007000 = CMF-300-6(Aux. Power) 0 x 0.008000 = 0 x 0.020000 = MMF-302 (Aux. Power) 0 x 0.012000 = 0 x 0.090000 = MMF-302-6(Aux. Power) 0 x 0.050000 = 0 x 0.270000 = B200SR(Aux. Power) 0 x 0.000500 = 0 x 0.035000 = B200SR-LF(Aux Power) 0 x 0.001000 = 0 x 0.125000 = SWIFT Wireless W-GATE 0 x 0 040000 = 0 x 0.040000 = W-DIS-D 0 x 0.030000 = 0 x 0.030000 = Miscellaneous Devices 9 x 0.020000 = 0.180000 9 x 0.000000 = 0.000000 0 x 0.000000 = 0 x 0.000000 _ 0 x 0.000000 = 0 x 0.000000 = 0 x 0.000000 = 0 x 0.000000 = 0 x 0.000000 = 0 x 0.000000 = Output Circuits NAC/Output#1 0 000000 = 2.200000 = 2.200000 NAC/Output#2 0.000000 = 1.200000 = 1.200000 NAC/Output#3 0.000000 = 0.000000 = NAC/Output#4 0 000000 = 0.000000 = Current Draw from TB3 0.000000 = 0.000000 = Total Standby Load 0.343600 Total Alarm Load 4.075000 Fire-Lite Alarms Page 2 8/6/2015 IFi re{ITe AL I s by Honeywell MS-92000DLS Rev.3 Battery Calculation Calculation in Total Sheet Required Standby Time in Hours 24 Hours Standby Load Current 0.34360 Amps x 24 = 8.246 AH Required Alarm Time in Minutes 5 Minutes Alarm Load Current(Amps) 4.07500 Amps x 0.084 = 0.342 AH Total Current Load 8.589 AH Multiply by the Derating Factor 1.2 = x 1.20 Total Ampere Hours Required 10.31 AH Recommended Batteries: BAT-12120-12AH Batteries Battery Check The batteries can be charged by the MS-92000DLS Charger. The batteries can be housed in the MS-92000DLS Cabinet. Current Draw Check NAC#1 current is within the limitations of the circuit NAC#2 current is within the limitations of the circuit. NAC#3 current is within the limitations of the circuit. NAC#4 current is within the limitations of the circuit. MS 92000DLS Control Panel: An Additional XRM-24B Transformer is required to meet current draw requirements. Fire-Lite Alarms Page 3 8/6/2015 SYSTEM SPECIFICATIONS System Capacity 16.65" (42 29 cm.)wide x 5.20" (13.34 cm.)deep.Trim Ring • Intelligent Signalling Line Circuits 1 (TR-CE):22 00"(55 88 cm)high x 19.65"(49.91 cm.)wide. • Addressable device capacity .... ... ...... . 198 Shipping Specifications • Programmable software zones 99 Weight:26.9 lbs. (12.20 kg.)Dimensions:20.00"(50.80 cm.) • ACS Annunciators 32 high x 22.5"(57.15 cm.)wide x 8.5"(21.59 cm.)deep. • ANN-bus devices... 16 Temperature and Humidity Ranges Electrical Specifications This system meets NFPA requirements for operation at 0 — AC Power: MS-92000DLS Rev 3: 120 VAC,60 Hz,3.0 amps. 49°C/32 — 120°F and at a relative humidity 93% ± 2% RH MS-92000DLS Rev 3E:240 VAC,5 0 Hz, 1.5 amps.Wire size: (noncondensing) at 32°C ± 2°C (90°F ± 3°F). However, the minimum 14 AWG(2.00 mm2)with 600 V insulation. useful life of the system's standby batteries and the electronic Battery charger capacity:7 AH- 18 AH batteries. Up to two components may be adversely affected by extreme tempera- 18 Ah batteries can be housed in the FACP cabinet. Larger ture ranges and humidity. Therefore, it is recommended that batteries require an external battery charger such as the CHG this system and its peripherals be installed in an environment 75 or CHG-120, and a separate battery cabinet such as the with a normal room temperature of 15—27°C/60—80°F. BB-26 or NFS-LBB Communication Loop:Supervised and power-limited. NFPA Standards Notification Appliance Circuits: Each terminal block pro- The MS-92000DLS Rev 3 complies with the following NFPA vides connections for two Style Y (Class B) for a total of four 72 Fire Alarm Systems requirements Style Y (Class B) or with an optional ZNAC-92 module con- —LOCAL (Automatic, Manual, Waterflow and Sprinkler verts to four Style Z(Class A) NACs. Maximum signaling cur- Supervisory) rent per circuit:2.5 amps. End-of-Line Resistor:4.7K ohm, 1/2 —AUXILIARY(Automatic, Manual and Waterflow) (requires watt(P/N 71252 UL listed)for Style Y(Class B)NAC. Refer to 4XTMF). panel documentation and Fire•Lite Device Compatibility Docu- _REMOTE STATION (Automatic, Manual, Waterflow and ment for listed compatible devices Sprinkler Supervisory) (Where a DACT is not accepted, Two Programmable Relays and One Fixed Trouble Relay: the alarm, trouble and supervisory relays may be con- Contact rating:2.0 amps @ 30 VDC(resistive),0.5 amps @ 30 nected to UL 864 listed transmitters. For reverse polarity VAC(resistive). Form-C relays. signaling of alarm and trouble,4XTMF is required.) Special Application Non-resettable Power(24 VDC Nomi- —PROPRIETARY (Automatic, Manual, Waterflow and nal): Jumper selectable (JP4) for conversion to resettable Sprinkler Supervisory). power output. Up to 1.0 amp total DC current available from —CENTRAL STATION (Automatic, Manual, Waterflow and each output.Power-limited. Sprinkler Supervisory). Special Application Resettable Power (24 VDC nominal): —OT, PSDN (Other Technologies, Packet-switched Data Jumper selectable (JP6) for conversion to non-resettable Network) power. Up to 1.0 amp total DC current available. Refer to the Fire•Lite Device Compatibility Document for listed compatible Agency Listings and Approvals devices. Remote Sync Output: Remote power supply synchronization The listings and approvals below apply to the basic MS- output. Nominal special application power:24 VDC. Maximum 92000DLS Rev 3 control panel. In some cases, certain mod current: 300 mA. End-of-Line Resistor 4.7K ohm. Output ules may not be listed by certain approval agencies, or listing linked to NAC 1 control Supervised and power-limited may be in process.Consult factory for latest listing status. • Telephone Interface:Unless used with Teldat VISORALARM, UL Listed:S624 requires dedicated business telephone number with a mini- • FM approved mum of 5 volts DC(off-hook voltage) Obtain dedicated phone • CSFM:7165-0075:0208 line directly from your local phone company.Do not use shared • MEA: 120-06-E phone lines or PBX(digital)type phone line extensions. For ULC listed version,see DF 60599. Cabinet Specifications Door: 19.26" (48.92 cm.) high x 16 82" (42.73 cm.) wide x FireLite®Alarms®is a registered trademark of Honeywell International Inc 0.12" (.30 cm) deep. Backbox: 19.00" (48.26 Cm.) high X Wheelock®is a registered trademark of and ExcederTM is a trademark of Cooper Notification ©2010 by Honeywell International Inc All rights reserved Unauthorized use of this document is strictly prohibited. 1S0 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements OERYIFIEEP ENCINEEAINC&MANOFACUIRING All specifications are subject to change without notice + "" °"'" — QUALITY SYSTEMS Made inthe US A For more information,contact Fire•Lite Alarms Phone'(800)627-3473,FAX (877)699-4105. www firelite.com Page 6 of 6—DF-60601.A1•12/07/2010 DF-60601:Al •Al-60 MS-92000DLS(E) Rev 3 ec144Fire uTe°ALarms Intelligent Addressable FACP with Built-In Communicator by Honeywell .', , ' - r 1, ,aa ®. Address Frre tarrn Son ral: 1„ General , , The Fire•Lite MS-92000DLS Rev 3 with Version 5.0 firmware : + is a combination FACP (Fire Alarm Control Panel) and DACT xk rkil (Digital Alarm Communicator/Transmitter) all on one circuit '• , ���- board This compact intelligent addressable control panel has s �4 an extensive list of powerful features. v ,. e While the MS-92000DLS Rev 3 may be used with an SLC ��°'. .°` Z 04 configured in the CLIP(Classic Loop Interface Protocol)mode, '��" it can also operate in LiteSpeedTM mode—Fire•Lite's latest • • _ polling technology—for a quicker device response time. , � - r LiteSpeed's patented technology polls 10 devices at a time. `7 i.,, .. gu, , This improvement allows a fully-loaded panel with up to 198 •r,.,, M devices to report an incident and activate the notification cir- 8f ' • cults in under 10 seconds With Litespeed polling,devices can be wired on standard twisted,unshielded wire up to a distance ' r f . of 10,000 feet - sa rots t.•:--..- k , ° fi!'!I fLARM CQ1�liLG fAM'. The MS-9200UDLS Rev 3's quick-remove chassis protects the ' . electronics during construction. The backbox can be installed allowing field wiring to be pulled When construction is com- pleted, the electronics can be quickly installed with just two °.' . bolts. - New features for Rev 3 with Version 5.0 firmware include Fl{OdTb"A1f3t S ry removable terminal blocks, improved transient protection, • additional secondaryANN-BUS, and increased power for the r f� resettable and remote sync outputs. Available accessories include ANN-BUS devices as well as Features - ACS LED, graphic and LCD annunciators, and reverse polar • Listed to UL standard 864,9th edition. ity/city box transmitter. • The integral DACT transmits system status(alarms,superviso On board DACT. ries,troubles,AC loss,etc.)to a Central Station via the public • Remote site or local USB port upload/download, using PS switched telephone network It also allows remote and local Tools. programming of the control panel using the PS-Tools Upload/ • Four(4)Style Y(Class B) NAC circuits,which can be con- Download utility. In addition, the control panel may be pro- verted to four (4) Style Z (Class A) circuits with optional grammed or interrogated off-site via the public switched tele- ZNAC-92 converter module. (Up to 6 0 amps total NAC phone network.Any personal computer with Windows®XP or power when using optional XRM-24B.) greater, a compatible modem, and PS-Tools—the Fire•Lite • Selectable strobe synchronization for System Sensor, Upload/Download software kit—may serve as a Service Termi- Wheelock,and Gentex devices. nal. This allows download of the entire program or upload of • Remote Acknowledge,Silence,Reset and Drill via address- the entire program, history file, walktest data, current status able monitor modules or LCD-80F,ANN-80 or Legacy ACS and system voltages. The panel can also be programmed Annunciators. through the FACP's keypad or via a standard PS-2 computer keyboard,which can be plugged directly into the printed circuit • ANN-BUS for connection to following optional modules(cannot board. This permits easy typing of address labels and other be used if ACS annunciators are used): programming information. —ANN-80(-W)Remote LCD Annunciator Version 5.0 firmware supports the following: Primary and Sec- —ANN-I/O LED Driver ondary ANN-bus devices,AD355(LiteSpeed),USB port,NAC —ANN-S/PG Printer Module circuit diagnostics, a new report has been added to the walk- —ANN-RLY Relay Module test that lists untested devices,new device types added.audio —ANNLED Annunciator Module telephone type code for ACC 25/50ZST, Photo Supervisory and auto-resettable Drill(non-latching). —ANN-RLED Annunciator Module alarms only The FireWatch Series internet monitoring modules IPDACT-2 —ROME Relay Option Module Enclosure and IPDACT-2UD permit monitoring of alarm signals over the • 'ACS/TERM: Internet saving the monthly cost of two dedicated business —ACS Annunciators: Up to 32 Legacy ACM Series annun- telephone lines. Although not required, the secondary tele- ciators(ACM-16AT or ACM-32 series). Cannot be used if phone line may be retained providing backup communication ANN-BUS devices are used. over the public switched telephone line. —Terminal-mode Annunciators: Up to 32 Legacy LCD-80F NOTE: Unless otherwise specified, the term MS-92000DLS is remote annunciators. used in this document to refer to both the MS-92000DLS and the MS-92000DLS(E)FACPs(Fire Alarm Control Panels) DF-60601:Al•12/07/2010—Page 1 of 6 • EIA-232 printer/PC interface (variable baud rate) on main • Supervisory(yellow) circuit board,for use with optional UL-listed printer PRN-6F. • Alarm Silenced(yellow) _ • Integral 80-character LCD display with backlighting • System Trouble(yellow) • Real-time clock/calendar with automatic daylight savings • Maintenance/Presignal(yellow) control. • Disabled(yellow) _ • Detector sensitivity test capability(NFPA 72 compliant) • Battery Fault(yellow) • History file with 1,000-event capacity. • Ground Fault(yellow) • Maintenance alert warns when smoke detector dust accu- mulation is excessive. KEYPAD CONTROLS • Automatic device type-code verification • Acknowledge/Step • One person audible or silent walk test with walk-test log and • Alarm Silence printout. • Drill • Point trouble identification. • System Reset(lamp test) • Waterflow(nonsilenceable)selection per monitor point. • 16-key alpha-numeric pad(similar to telephone keypad) • System alarm verification selection per detector point. • 4 cursor keys • PAS (Positive Alarm Sequence) and presignal delay per • Enter point(NFPA 72 compliant) NOTE:Only detectors may participate in PAS Product Line Information SLC LOOP: MS-92000DLS: 198-point addressable Fire Alarm Control • SLC can be configured for NFPA Style 4,6,or 7 operation Panel, one SLC loop. Includes 80-character LCD display, sin- • SLC supports up to 198 addressable devices per loop (99 91e printed circuit board mounted on chassis,and cabinet. 120 detectors and 99 monitor,control,or relay modules). VAC operation. • SLC loop maximum length 10,000 ft (3,000 m.). MS-92000DLSE: Same as MS-92000DLS, except with 240 See installation manual for wire tables VAC operation NOTIFICATION APPLIANCE CIRCUITS(NAGS): 4XTMF Reverse Polarity Transmitter Module: Provides supervised output for local energy municipal box transmitter, • Four onboard NACs with additional NAC capability using alarm,and trouble. output control modules(CMF 300 or CMF-300-6) The four ZNAC-92: Optional converter module which converts four (4) Class B NACs can be converted to four Class A NACs with Style Y(Class B)NAC circuits to four(4)Style Z(Class A)cir optional ZNAC-92 converter module. cwts • Silence Inhibit and Auto Silence timer options. PK-CD Programming software for Windows®-based PC com- • Continuous, March Time, Temporal or California code for main circuit board NACs with two-stage capability. puter(cable not included),available on www firelite com. • Selectable strobe synchronization per NAC DP-9692:Optional dress panel for MS-92000DLS Rev 3 • 2.5 amps maximum per each NAC circuit TR-CE:Optional trim Ring for semi-flush mounting. NOTE:Maximum 24VDC system power output is shared among BB-26: Battery backbox, holds up to two 25 AH batteries and all NAC circuits and 24VDC special-application auxiliary power CHG-75 outputs Total available output is 3 0 amps Using the optional BB-55F: Battery box,houses two 55 AH batteries. XRM-24B transformer increases 24VDC output to 6 0 amps PROGRAMMING AND SOFTWARE: CHG-75: Battery charger for lead-acid batteries with a rating of 25 to 75 AH • Autoprogram(learn mode) reduces installation time CHG-120F: Remote battery charging system for lead-acid bat- • Custom English labels(per point)may be manually entered teries with a rating of 55 to 120 AH. Requires additional BB- or selected from an internal library file. 55F for mounting. • Three Form-C relay outputs(two programmable) BAT Series:Batteries,see data sheet DF-52397 • 99 software zones XRM-24B(E): Optional transformer. Increases system power • Continuous fire protection during online programming at the output to 6.0 amps. Use XRM-24BE with MS-92000DLS Rev front panel. 3(E) • Program Check automatically catches common errors not PRT/PK-CABLE: Cable printer/personal computer interface linked to any zone or input point. cable; required for printer or for local upload/download pro- • OFFLINE PROGRAMMING: Create the entire program in gramming and updating panel firmware your office using a Windows®based software package PRN-6F: UL listed compatible event printer. Uses tractor-fed (order programming kit PS-Tools, separately) Upload/ download system programming locally to the MS- paper. 92000DLS Rev 3 in less than one minute. IPDACT 2/2UD, IPDACT Internet Monitoring Module: • USB upload/download programming with standard Male-A Mounts in bottom of enclosure with optional mounting kit(PN to Male-B cable. IPBRKT). Connects to primary and secondary DACT tele- phone output ports for internet communications over customer User Interface provided ethernet Internet connection. Requires compatible Teldat VisorALARM Central Station Receiver. Can use DHCP LED INDICATORS or static IP. (See data sheet DF-60407 or DF-52424 for more ' information) • AC Power(green) • Fire Alarm(red) . Page 2 of 6—DF-60601.A1•12/07/2010 IPBRKT: Mounting kit for IPDACT-2/2UD in common enclo- DNRW: Innovair Flex low-flow non-relay duct-detector hous- sure ing, with NEMA-4 rating. Watertight. (Order SD355R sepa- IPSPLT: Y-adaptor option allows connection of both panel rately.) dialer outputs to one IPDACT-2/2UD cable input MMF-300: Addressable Monitor Module for one zone of nor- COMPATIBLEANNUNCIATORS mally-open dry-contact initiating devices. Mounts in standard 4 0" (10.16 cm.) box. Includes plastic cover plate and end-of- ANN-80(-W): LCD Annunciator is a remote LCD annunciator line resistor. Module may be configured for either a Style B that mimics the information displayed on the FACP LCD dis- (Class B)or Style D(Class A)IDC play. Recommended wire type is un-shielded:(Basic model is MDF-300: Dual Monitor Module. Same as MMF-300 except it red;order-W version for white;see DF-52417.) provides two Style B(Class B)only IDCs. ANN-LED:Annunciator Module provides three LEDs for each MMF-301: Miniature version of MMF-300. Excludes LED and zone: Alarm, Trouble and Supervisory. Ships with red enclo- Style D option. Connects with wire pigtails. May mount in sure(see DF-60241). device backbox. ANN-RLED: Provides alarm(red)indicators for up to 30 input MMF-302:Similar to MMF-300,but may monitor up to 20 con- zones or addressable points. (See DF-60241). ventional two-wire detectors. Requires resettable 24 VDC ANN-RLY: Relay Module, which can be mounted inside the power.Consult factory for compatible smoke detectors. cabinet, provides 10 programmable Form-C relays. (See DF- , 52431.) ROME: Relay Option Module Enclosure. Provides one ANN- RLY Relay Module already installed. The ROME Series pro- vides mounting space for one additional Relay Module or one addressable Multi-module (See Installation Sheet PN 53530.) ANN-S/PG:Serial/Parallel Printer Gateway module provides a connection for a serial or parallel printer.(See DF-52429) ANN-I/O: LED Driver Module provides connections to a user supplied graphic annunciator.(See DF-52430) ACM-8RF: Relay module provides 8 Form-C 5 0 amp relays. ACS-LED Zone Series:LED-type fire annunciators capable of providing up to 99 software zones of annunciation Available in increments of 16 or 32 points to meet a variety of applications. LDM Graphic Series: Lamp Driver Module series for use with custom graphic annunciators. LCD-80F (Liquid Crystal Display) point annunciator: 80-character, backlit LCD-type fire annunciators capable of displaying English-language text. NOTE:For more information on Compatible Annunciators for use with the MS-92000DLS Rev 3,see the following data sheets(doc- ument numbers) ACM-8RF (DF-51555), ACS/ACMSenes (DF- 52378),LDM Senes(DF-51384),LCD-80F(DF-52185) LITESPEED COMPATIBLE ADDRESSABLE DEVICES All feature a polling LED and rotary switches for addressing. CP355:Addressable low-profile ionization smoke detector. SD355:Addressable low-profile photoelectric smoke detector. SD355T: Addressable low-profile photoelectric smoke detec- tor with thermal sensor. SD355R: Addressable remote test capable detector for use with D355PL or DNR(W)duct smoke detector housings. H355: Fast-response,low-profile heat detector. H355R: Fast-response, low-profile heat detector with rate-of- rise option. H355HT: Fixed high-temperature detector that activates at 190F/88C. AD355(A): Low-profile,intelligent,"Adapt"multi-sensor detec- tor(B350LP base included). BEAM355: Intelligent beam smoke detector BEAM355S: Intelligent beam smoke detector with integral sensitivity test. D355PL: Innovair Flex low-flow non-relay duct-detector hous- ing.SD355R included DF-60601:A1•12/07/2010—Page 3 of 6 CMF-300: Addressable Control Module for one Style Y/Z v__ (Class B/A) zone of supervised polarized Notification Appli- _ ances. Mounts directly to a 4.0" (10.16 cm.) electrical box. " Notification Appliance Circuit option requires external 24 VDC to power notification appliances ' CRF-300: Addressable relay module containing two isolated - v sets of Form-C contacts, which operate as a DPDT switch Y Mounts directly to a 4 0" (10 16 cm.)box,surface mount using -fig - ;, the SMB500. • °" BG-12LX:Addressable manual pull station with interface mod- MS-92000DLS Remote ACC-25/50(ZS/T) ule mounted inside. Fire Alarm Microphone Audio Command Control Panel Center 1300: Fault Isolator Module.This module isolates the SLC loop cL from short circuit conditions (required for Style 6 or 7 opera- tion). SPR a N Speaker o SMB500:Used to mount all modules except the MMF-301 and ,,--", > M301 F5 `..` SPC MMF-300-10: Ten-input monitor module. Mount one or two SD355 �,,e,;1"ri h ' Series , i '' '. modules in a BB-2F cabinet (optional). Mount upto six mod- Photo Detector - I Speaker , ;'..„ " ( p ) t, `M i _ ules on a CHS-6 chassis in a BB-6F. LCD-80F _m . , MMF-302-6:Six-zone interface module for compatible conven- -_'''s _ _ ran_ P , , tonal two-wire detectors Mount one or two modules in a BB- .0z,„—_,:‘,0- ,:::f„; 7:i' 2F cabinet (optional). Mount up to six modules on a CHS-6 AD355 ;: March 17,2005 DF-51410•1-100 e(144 i v ®AL FM Series Electromagnetic Door Holders • www.firelite.com Section. Miscellaneous GENERAL FM Series electromagnetic door holders are designed for BSA WI EA virtually any remote door release application.They are pri- °" 447-00-E manly used to hold fire and smoke barrier doors open untilta (FM980, FM998) released by a remote smoke detector or other switching device The complete assembly consists of: an armature LASTS® contact plate with adjustablepivot mountingfor installation State e J R11746 � State Fire in the door, and a heavy-duty electromagnet, in a durable Marshal Marshal plastic enclosure, mounted on the wall or floor behind the av, 3550-0075.173 door.A separate closing device is required. FEATURES ;.1 la', • All models support 12 VDC,24 VACNDC,or 120 VAC. ; • Improperly applied voltage does not damage the unit. ' • Spacing kit for odd angles. w� ' • 25 to 40 pounds (11.3 kg) holding power. • Magnet protected against transients and surges up to r 600 volts (AC models). F fixIt „A , . ' te , fl° 16, • Fail-safe operation;power failure releases door to close. • Positive release button initiates closing motion. a . ° ��` • Two-year warranty. 44, • Floor-and wall-mount models. 5286phi1p8 � a . INSTALLATION • Used in hospitals, schools, offices, nursing homes, and FM996 public buildings. °w • Install where required by code,where doors may be used to confine smoke or fire, or wherever remote control or automatic closing doors are required. • Ensure that door hardware and trim projections are com- patible with total projection of door release. ORDERING INFORMATION • Anchor the electromagnet firmly, as the wall portion will FM980 Surface floor-mount model for single function as a doorstop. door; 12 VDC,24 VACNDC, 120 VAC • Locate magnet approximately 6" (15 24 cm) in from the FM996 Surface wall-mount model, 12 VDC, 24 lock stile at the door. Wall magnets should be mounted VAC/VDC, 120 VAC approximately two to four feet(0.61 to 1.22 meters)above the floor for optimum performance. FM998 Flush wall-mount model; 12 VDC, 24 • Door-mounted contact plate includes hardware for VAC/VDC, 120 VAC. thrubolting or concealed mounting. FM900 Extension kit. • Spotting template included with unit assures correct align- FM900-Z Extension kit, 90° ment. • 14 AWG (2.0 mm2) maximum wire size FM900-50 Spacer, 1/2" (1.27 cm). FM900-75 Spacer, 3/4" (1.905 cm) FM-900-100 Spacer, 1" (2.54 cm). • Fire•Lite®Alarms is a Honeywell company This document is not intended to be used for installation purposes We try to keep our product informa4 9001 - tion up-to-date and accurate We cannot cover all specific applications or anticipate all requirements All specifications are subject to change without notice CE'RT#,F For more information,contact Fire•Lite Alarms,One Fire-Lite Place,Northford,Connecticut 06472 Phone ENGINEERING U MANUFACTURING (800)627-3473,Toll-Free FAX (877)699-4105 QUALITY SYSTEMS DF-51410•03/17/05 — Page 1 of 2 4-3/4"(120.65 mm) 5"(127.00 mm) 1-5/8 �- ® (41.275 mm) ki 1-3/4" (44.45) -.-allit414 — 3-118" — — I2-17132" F ______ (69 )t - l' 5286m980 of p • Concealed wiring. • UL-Listed door holder. MODEL 980 • Total floor space required: • Voltage/current: Floor-Mount 6-5/8" (168 mm). 120 VAC, 60 Hz, 0.020 amp. Single Door • Mounting requirements: 24 VAC/VDC, 60 Hz,0.020 amp. g Conduit connects 12 VDC, 0 040 amp. directly to floor plate. • Shipping weight: 4 lbs (1.8 kg). MODEL 996 2-3/4" Wall-Mount 2-1/2" (69.85 mm) (63 5 mm) m (41 275) 1 Surface Wiring / 1-5/8" 1-3/4" (44.45) 1 AII 4 5/S" �� 2-17/32" L-, 1 (117.475 mm) � (24 294) �',� I I I111,11t - is '-- / Pi a I I II 111 1 5286m996 titII • Total projection: 4-1/8" (105 mm). • Voltage/current: • Mounting requirements: 120 VAC,60 Hz, 0.020 amp. 1-1/2" (38 mm) deep adapter housing. 24 VACNDC,60 Hz,0.020 amp. • UL-Listed door holder. 12 VDC,0.040 amp. • Shipping weight: 3 lbs. (1.4 kg). I . . 2-3/4" ' 1"(25.40 mm) (69.85 mm) /rill2-5/8" 1-3/4" (66 675) 0 (44 45) 1. 4 5/8" 5 , OIjIkill 2-17/32" , I (117 475 mm) ti ,i (2494) _ wie I to1 T` r 5286m998 UI • Total projection: 3-5/8" (92 mm). •UL-Listed door holder. MODEL 998 • Mounting requirements. • Voltage/current: 2"x 4"x 1-3/4" (51 x 102 x 45 mm) 120 VAC, 60 Hz, 0.020 amp. 4 Wall-Mount outlet box 24 VAC/VDC, 60 Hz, 0.020 amp. Standard Doors • Wall must be properly reinforced and 12 VDC, 0.040 amp. ,. Concealed Wiring outlet box adequately fastened. • Shipping weight:2-1/2 lbs. (1.1 kg). - Page 2 of 2 — DF-51410•03/17/05 /7 ::;:t�//��/YYY/1!/ Yy,, ,a; 4, 1 . 1 , . ,! , R _ /ls®,�1/l' � � _ /-:-/////////l/ ///1///////11 %//////Ill/ �' PS-124.20.. :12 Volt .l1 •0. 11-1 : . 4 ; ''''''''''-'4'' a�-----;, Ar-t. -Pt•--.. A t; ,, „, -- ikie, se ;-,:, ...: 4,,-, ,',.1„,,,,,,''-frrr.!-4,-,feviA,, i 1chabIéaIe44Mfr*4 '� � �°�a _ `S+, :a�.� . �, g" f..... ti .t>is& ' w. F „ • Absorbent Glass Mat (AGM) technology for superior performance • Valve regulated, spill proof construction allows safe tea « Wig = operation in any position „' ” ,12220 : ;;. " Power/volume ratio yieldingunrivaled energydensity ,,, �:' r0oot c 't' Nr. './ y 4„$ ,2,...:,, rc ,Aa " ',...'..:..r`=°' -. °' %, • Rugged impact resistant ABS case and cover (UL94 HB) c t `" u� * . k • Approved for transport by air. D.O.T., I.A.T.A., F.A.A. and C.A.B. certified • U.L. recognized under file number MH 20845 T,.iminals: (i.o , - performance „. -- cations ` , 1-34-1 Nominal Voltage 12 volts (6 cells) • F2-Quick disconnect tabs,0 250"x 0.032" ° 11sis Nominal Capacity Mate with AMP INC 20 hr. (600mA to 10.50 volts) 12.0 AH FASTON"250"series I-795- I � n=0 8 10-hr. (1.1A to 10.50 volts) 11.0 AH • NB-Tin plated brass �� ,__,2 5-hr. (2.1A to 10.20 volts) 10.5 AH posts with nut&bolt 4 O �I Itt 1-hr. (7.25A to 9.00 volts) 7.25 AH fasteners 15-min. (21.5A to 9.00 volts) 5.38 AH IP,ysl�at., .e tslo'ns: 1n �ttf � Approximate Weight 7.92 lbs. (3.59 kg) Energy Density(20-hr. rate)033 I 1.69 W-h/in3 (103.41 W-h/I) Specific Energy(20-hr. rate) 18.18 W-h/lb (40.08 W-h/kg) W Internal Resistance (approx.) 20 milliohms 03 je Max Discharge Current(7 Min.) 36.0 amperes Max Short-Duration Discharge Current(10 Sec.).. 120.0 amperes Shelf Life(%of nominal capacity at 68°F (20°C) IT I 1 Month 97% 3 Months 91% gn,".'"'-'7.-".Sonic. = HT H MObEL PS-12110 F3 6 Months 83% a= ..t:Z��^ti_ V , I Operating Temperature Range `� - Charge -4°F (-20°C) to 122°F (50°C) 'F2:'L..5.94.(l51)mW:',3.86`(98).H: ' "6✓(93)'HHT ie6(98) ,, Discharge -40°F (-40°C) to 140°F (60°C) "" ``" `" " Case ABS Plastic '''-NB:.-:5.94(15))°W:3.86-(98) H:-3:66(93)HT:4 09(104)0.; Power-Sonic Chargers PSC-122000A, 122000A-C Tolerances are+/-0 04 in (+/-1 mm)and+/-0.08 in (+1-2mm)for height dimensions.All data subject to change without notice To ensure safe and efficient operation always refer to fheslatest edihon n.ur Techmcati ual,as publisfied on our website a , r, All data subject to,change rethouY iohce G `t a` iC; a WWW. OW@C S 9 c CO►1 : .,2... .-4A-,,,,it:-.A-,,,C4,44,,, *, '" tx '::' y a is „ �� �. 11.::. 1¢EP 1212 .� . POL!/E/Pf,%/� °t s S 1 . 0 12'Volt 12.0 �C1=1' Shelf Life & Storage Discharge Characteristics t 100 Charging14.0 III I I I I I I I eyi Ambient Temperature 20°C(68°F) O (i 100%ofcapaaty 13.0 = • t ismgwred =C_CF. 4 re• 80 _ _____ 5°C °Charging before E 12.0 C # use Is necessary fu - -(41°F)- p to helprecover rn C } full capacity A -- y; 60 . p 11.0 .._ , Chagemayfal > kik if 40°C 30°C to restore full is 0.60 20°C ) capacity Do not a 10.0 1.2 5 40 (104°F) (86°F) (68°F) let battenes reach E 2.4 aco 0 r I I I this state d Final 6.0 V 0 2 4 6 8 10 12 14 16 18 20 Voltage 12 Standing Period(Months) 8.0 III 24 . 1.2 2.4 6 12 24 36 48 1 2 4 6 810 20 4 0 Discharge Time vs. Discharge Current ff min 1 h--"'I T Discharge Time 20 15 \ 10 \\ Life Characteristics in Stand-By Use L a1 5 Final a 1DD AmbientTemperature 20°C(68°F) E Voltage a `" `civ -- -'17-4----1-----;,,, i= 2 10.5V \\ 80 ` y 63 Pt 10.2V ao 60 w cc - 1 \ 40 Float Charging Voltage 2.25-2.30 V/Cell G 30 9.6V \\ aaa 20 \ m re \ 0 E 9.0V 0 1 2 3 4 10 \ 40°C(104°F) . Years 20°C (68°F) 0°C (32°F) 5 8.1 Life Characteristics in Cyclic Use 0.60 1.2 2.4 6.0 12 24 120 Discharge Current(A) �`;I y i ,'• "P'!'" �R • e 100 ,\\'\•,,,,,, -. ` »..„.. Char �n � , .:,��9 . �, 80 �.>, ,* .. Cycle Applications:Limit initial current to 3 6A.Charge until battery voltage(under m 1, charge)reaches 14.4 to 14 7 volts at 68°F(20°C).Hold at 14 4 to 14.7 volts until m 60 Discharge Discharge Discharge current drops to under 120mA Battery is fully charged under these conditions,and 0 Depth 100% Depth 501 Depth i 0% charger should be disconnected or switched to"float"voltage 2 40 d 1.Discharge Current 0.2C(Final Voltage 1.7V/Cell) "Float"or"Stand-By"Service:Hold battery across constant voltage source of 13 5 y 20 2.Charge Current:0.1C I I I to 13 8 volts continuously When held at this voltage,the battery will seek its own o: 3.Ambient Temperature:20°C to 25°C(68°F to 77°F) current level and maintain itself in a fully charged condition. I I I I I 0 Note.Due to the self-discharge characteristics of this type of battery,it is imperative 0 200 400 600 800 1000 1200 that they be charged within 6 months of storage,otherwise permanent loss of Number of Cycles capacity might occur as a result of sulfation 'Char•to s .' � r r, R�# . . 9 tea Q urther lnform,�at.on, . #.' , Power Sonic offers a wide range of chargers suitable for batteries up to l OOAH. Please refer to our website www power-sonic com for a complete range of useful Please refer to the Charger Selection Guide in our specification sheets for"C-Series downloads,such as product catalogs,material safety data sheets(MSDS),ISO Switch Mode Chargers"and"Transformer Type A and F Series" Please contact our certification,etc. Technical department for advice if you have difficulty in locating suitable models C tact nfolrltnpti0111C 1 : :".'-iiia ..`fit•; � "' w:,$i>pow,er,-sonlc.com' DOMESTIC SALES CUSTOMER SERVICE TECHNICAL SUPPORT INTERNATIONAL SALES I, -,N Tel.+1-619-661-2020 Tel.+1-619-661-2030 Tel +1-619-661-2020 Tel +1-650-364-5001 Fax +1.619-661-3650 Fax +1-619-661-3648 Fax +1-619-661-3648 Fax.+1-650-3663662 nahonal-sales@power-sonic com customer-service@power--sonic com support@power-sonic com intemahonalsales@power-sonic corn CORPORATE OFFICE•7550 Panasonic Way•San Diego,CA 92154•USA•Tel +1-619-661-2020•Fax.+1-619-661-3650 0814 1M 02013 Power-Sonic Corporation All nghts reserved All trademarks are the property of their respective owners DF-52384.D•E-160 SD355(A) Series el<144 Fire•LITGALarms Addressable Photoelectric Smoke Detectors by Honeywell ,, p ?' dressable Devices General The SD355(A), SD355T(A), and SD355R(A) addressable, low-profile plug-in photoelectric detectors use a state-of-the- ' - art photoelectric sensing chamber with communications to $ provide open area protection and are used exclusively with Fire•Lite's Addressable Fire Alarm Control Panels (FACPs). The SD355T(A)adds thermal sensors that will alarm at a fixed0 temperature of 135°F (57°C). Since these detectors are , addressable, they will help emergency personnel quickly a locate a fire during its early stages,potentially saving precious rescue time while also reducing property damage.Two LEDs `,' 5 on each sensor light to provide a local, visible sensor indica- tion ndica tion Remote LED annunciator capability is available as an optional accessory, PN RA100Z(A). The SD355R(A) is a SD355(A) in B210LP(A) Base remote test capable detector for use with D355PL(A) or DNR(A)/DNRW duct smoke detector housings Features OPTIONS • Remote LED output connection,PN RA100Z(A). SLC LOOP • Two-wire loop connection. Applications • Unit uses base for wiring Use photoelectric detectors in life-safety applications to pro- ADDRESSING vide a broad range of fire-sensing capability, especially where smoldering fires are anticipated. Ionization detectors are often • Addressable by device. better than photoelectric detectors at sensing fast, flaming • Rotary,decimal addressing:01 —99 with MS-92000D(LS), fires. and 01 —159 with MS-9600UD(LS). ARCHITECTURE Construction • Unique single-source, dual-chamber design to respond These detectors are constructed of off-white fire resistant plas- quickly and dependably to a broad range of fires. tic. SD355(A) series plug-in, low-profile smoke detectors are Sleek,low profile design. designed to commercial standards and offer an attractive • appearance. • Integral communications and built-in type identification • Built-in tamper-resistant feature. Installation • Removable cover and insect resistant screen for simple SD355(A)series plug-in detectors use a detachable mounting field cleaning. base to simplify installation,service and maintenance. OPERATION Mount base (all base types)on an electrical backbox which is • Withstands air velocities up to 4,000 feet-per-minute(20 m/ at least 1 5"(3.81 cm)deep For a chart of compatible junction sec.)without triggering a false alarm. boxes,see DF-60059. • Factory preset at 1.5% nominal sensitivity for panel alarm NOTE:Because of the inherent supervision provided by the SLC threshold level. loop, end-of-line resistors are not required. Wiring `T-taps" or • Visible LED"blinks"when the unit is addressed (communi- branches are permitted for Style 4 (Class B) wiring SD355R(A) eating with the fire panel)and latches on in alarm. mounts in a D355PL(A)or DNR(A)/DNRW duct detector housing. MECHANICALS Operation • Sealed against back pressure. Each SD355(A) series detector uses one of 99 possible • Direct surface mounting or electrical box mounting. addresses on the MS-9200UD(LS) and up to 318 (159 on • Mounts to: single-gang box, 3.5" (8.89 cm) or 4.0" (10.16 each loop) on the MS-9600UD(LS) Signaling Line Circuit cm)octagonal box,or 4.0"(10.16 cm)square electrical box (SLC).It responds to regular polls from the system and reports (using a plaster ring—included). its type and status. OTHER SYSTEM FEATURES The addressable photoelectric sensor in the SD355(A)series has a unique unipolar chamber that responds quickly and uni- • Fully coated circuit boards and superior RF/transient pro- formly to a broad range of smoke conditions. It can withstand tection. wind gusts up to 4,000 feet-per-minute (20 m/sec.) without • 94-VO plastic flammability rating. sending an alarm level signal. Because of its unipolar cham- • Low standby current. ber, the SD355(A) series is approximately two times more responsive than most photoelectric sensors. This makes it a more stable detector. DF-52384 D•2/11/2015—Page 1 of 2 Detector Sensitivity Test SD355RA: Same as SD355R with ULC Listing for use with a Each detector can have its sensitivity tested (required per D355PLA or DNRA duct detector housing; B210LPA base included. NFPA 72,Chapter 14 on Inspection, Testing and Maintenance) when installed/connected to a MS-92000D(LS) or MS- INTELLIGENT BASES 96000D(LS)addressable fire alarm control panel The results NOTE:A"suffix indicates ULC Listed model. of the sensitivity test can be printed off the MS-92000D(LS)or MS-96000D(LS)for record keeping NOTE:The detector's plug-in base can be changed off for special applications For details about intelligent bases and their mount- ing,see DF-60059. Specification B210LP(A): Plug-in detector base (included); standard U.S Voltage range: 15—32 VDC(peak). flanged low-profile mounting base. Standby current:300 pA @ 24 VDC B210LPBP: Bulk pack of B210LP;package contains 10. LED current:6.5 mA @ 24 VDC(latched"ON") B501(A):Standard European flangeless mounting base. Air velocity:4,000 ft./min. (20 m/sec.)maximum. B501BP:Bulk pack of B501;package contains 10 Size:2.1"(5.33 cm)high;base determines diameter B200SR(A): Intelligent sounder base capable of producing —B210LP(A):6.1"(15 5 cm)diameter sound output with ANSI Temporal 3 or continuous tone. —B501(A):4.1"(10 4 cm)diameter. Replaces B501 BH series bases in retrofit applications. —B200SR(A):6.875"(17 46 cm)diameter. B224RB(A): Plug-in System Sensor relay base. Screw termi- nals:up to 14 AWG(2.0 mm2).Relay type'Form-C.Rating:2.0 —B224RB(A):6.2"(15 748 cm)diameter. A @ 30 VDC resistive; 0.3 A @ 110 VDC inductive; 1.0 A @ Weight:3.6 oz.(102 g) 30 VDC inductive. Operating temperature range: for SD355(A): 0°C to 49°C B224BI(A): Plug-in System Sensor isolator detector base. (32°F to 120°F); for SD355T(A):0°C to 38°C(32°F to 100°F) Maximum 25 devices between isolator bases(see DF-52389). SD355R(A):installed in a DNR(A)/DNRW-20°C to 70°C(-4°F to 158°F) ACCESSORIES Temperature:0°C—49°C(32°F—120°F). F110: Retrofit flange to convert B210LP(A) to match the B350LP(A) profile, or to convert older high-profile bases to Relative humidity: 10%—93%,non-condensing low-profile. Listings F110BP:Bulk pack of F110;package contains 15. Listings and approvals below apply to the SD355(A), F210: Replacement flange for B210LP(A)base SD355T(A), and SD355RT(A) detectors. In some cases, cer- RA100Z(A): Remote LED annunciator.3—32 VDC Mounts to tain modules may not be listed by certain approval agencies, a U S single-gang electrical box. For use with B501(A) and or listing may be in process. Consult factory for latest listing B21 OLP(A)bases only status. SMB600:Surface mounting kit • UL Listed:S1059. M02-04-00:Test magnet. • ULC Listed:S1059 M02-09-00:Test magnet with telescoping handle • CSFM:7272-0075:0194 XR2B: Detector removal tool. Allows installation and/or • MEA:243-02-E removal of detector heads from bases in high ceiling applica- • FM approved. tions XP-4: Extension pole for XR2B Comes in three 5-foot Product Line Information (1.524 m)sections. NOTE:"A"suffix indicates ULC Listed model T55-127-010:Detector removal tool without pole. SD355: Addressable photoelectric detector; B21 OLP base BCK-200B: Black detector covers for use with SD355(A)only; included. box of 10. SD355R: Sames as SD355 with ULC Listing; B210LPA base WCK-200B: White detector covers for use with SD355(A) included. only;box of 10. SD355T: Same as SD355 but with thermal element; B21 OLP base included SD355TA:Same as SD355T with ULC Listing, B21 OLPA base included. SD355R: Remote test capable addressable photoelectric FireLite®Alarms is a registered trademark of Honeywell International Inc detector for use with a D355PL(A) or DNRA/DNRW duct ©2015 by Honeywell International Inc All rights reserved Unauthorized use detector housing;B21 OLP base included. of this document is strictly prohibited ISO 9001 This document is not intended to be used for installation purposes We try to keep our product information up-to-date and accurate • C E R T'I F,E O We cannot cover all specific applications or anticipate all requirements. ENCINEBINt 8 MANUFACTURING All specifications are subject to change without notice QUALITY SYSTEMS For more information,contact Fire•Lite Alarms Phone (800)627-3473,FAX.(877)699-4105. www firelite.com Page 2 of 2—DF-52384 D•2/11/2015 DF-52385:D•E-710 H355(A) Series Fire•uTeAtarms Intelligent Addressable Thermal Detectors by Honeywell. 4,,-„ r y ,• f a g >'t` iv E " ,°ressa e D vice '+ W J "-c ...ka".� h e. � a 1.t., General The Fire•Lite Alarms H355(A) Series thermal detectors are addressable sensors that use a state-of-the-art thermistor sensing circuit for fast response.These sensors provide open- -. ",'q; area protection and are intended for use with Fire•Lite's ' AMr, 4t- addressable Fire Alarm Control Panels(FACPs). 4 ,1 The H355(A) and H355R(A) sensors provide fixed tempera- � 4 u $;` ture alarm detection at 135°F (57°C). The H355R(A) sensor `"�.� ,.;� ` his:��," •`=' -- � also responds to rate-of-rise conditions of greater than 15°F ;. ,• 111, "aw Na (8.3°C) per minute. The H355HT(A) is a fixed high-tempera * " ture detector that activates at 190°F (88°C). These thermal j,:r" detectors provide addressable property protection in a variety of applications. Two LEDs on each sensor light to provide a local,visible sen- H355(A) in B210LP(A) Base sor indication. Remote LED annunciator capability is available using an optional accessory,the RA100Z • 94-5V plastic flammability rating Features Options: SLC loop: • Remote LED output connection to optional RA100Z remote LED annunciator. • Two-wire SLC loop connection • Flanged surface mounting kit. • Unit uses base for wiring. Addressing: Installation • Addressable by device. 11355(A) Series plug-in intelligent thermal detectors use a • Rotary,decimal addressing:01 —159 with MS-9600 series, detachable base to simplify installation, service and mainte- 01 —99 with MS-9200 series. nance.Installation instructions are shipped with each detector. Architecture: Mount base(all base types)on an electrical backbox which is • Sleek,low-profile,stylish design. at least 1.5"(3.81 cm)deep. For a chart of compatible Junction • State-of-the-art thermistor technology for fast response boxes,see DF 60059. • Integral communications and built-in device-type identifica- NOTE:Because of the inherent supervision provided by the SLC tion. loop, end-of-line resistors are not required. Wiring `T-taps" or branches are permitted for Style 4(Class"B")wiring only. • Built-in tamper resistant feature • Built-in functional test switch activated by external magnet. Applications Operation: Use thermal detectors for protection of property. • Factory preset at 135°F (57°C) for the H355(A) and H355R(A); 190°F(88°C)for the H355HT(A). Construction • Rate-of-rise triggers at 15°F (8 3°C) per minute for the H355R(A). These detectors are constructed of off-white fire-resistant 360°field viewing angle of the visual alarm indicators (two plastic The 11355(A) Series plug-in intelligent thermal detec- • tors are designed to commercial standards and offer an attrac- bicolor LEDs). LEDs blink red in Normal condition and turn tive appearance on steady red in Alarm. • Visible LEDs"blink"every time the unit is addressed. Operation Mechanicals: Each H355(A) Series detector uses one of 159 (MS-9600 • Sealed against back pressure. series) or 99 (MS-9200 series) possible addresses on a con- • SEMS screws for wiring of the separate base. trol panel SLC loop It responds to regular polls from the con- • Designed for direct-surface or electrical-box mounting. trol panel and reports its type and the status. If it receives a Plugs into separate base for ease of installation and main- test command from the panel(or a local magnet test), it stimu- • lates its electronics and reports an alarm. It blinks its LEDs tenance. when polled and turns the LEDs on when commanded by the • Separate base allows interchange of photoelectric, ioniza- panel. The 11355(A) Series offers features and performance tion and thermal sensors. that represent the latest in thermal detector technology. Other system features: • Remote test feature from the panel. • Walk test with address display • Low standby current. DF-52385 D•5/17/2013—Page 1 of 2 Spefications INTELLIGENT BASES Size:2.1" (5 3 cm)high;base determines diameter. NOTE:"A"suffix indicates ULC Listed model. —B210LP(A):6.1"(15.5 cm)diameter NOTE:The detector's plug-in base can be changed off for special applications. For details about intelligent bases and their mount- —B501(A):4.1"(10.4 cm)diameter ing,see DF-60059. • —B200SR(A):6.875"(17.46 cm)diameter. B210LP(A): Plug-in detector base (included); standard U.S. —B224RB(A):6.2" (15.748 cm)diameter flanged low-profile mounting base. Shipping weight:4.8 oz (137 g) B210LPBP: Bulk pack of B210LP; package contains 10. Installation temperature: B501(A):Standard European flangeless mounting base —H355(A), H355R(A).—4°F to 100°F(-20°C to 38°C). B501 BP: Bulk pack of B501;package contains 10 —H355HT(A):—4°F to 150°F(-20°C to 66°C). B200SR(A): Intelligent sounder base capable of producing Humidity range: 10% to 93% relative humidity (noncon- sound output with ANSI Temporal 3 or continuous tone densing). Replaces B501 BH series bases in retrofit applications Voltage range: 15 to 32 VDC peak. B224RB(A): Plug-in System Sensor relay base. Screw term- Standby current: 300 pA @ 24 VDC (one communication nals:up to 14 AWG(2 0 mm2) Relay type: Form-C.Rating:2.0 every five seconds with LED blink enabled) A @ 30 VDC resistive, 0 3 A @ 110 VDC inductive; 1.0 A @ 30 VDC inductive. LED current:6.5 mA @ 24 VDC. B224B1(A): Plug-in System Sensor isolator detector base Mounting: B210LP(A) flanged base, included. See "Product Maximum 25 devices between isolator bases(see DF-52389). Line Information.Intelligent Bases"if using a different base Fixed-temperature setpoint: 135°F (57°C) for the H355(A) ACCESSORIES and H355R(A), 190°F(88°C)for the H355HT(A) F110: Retrofit flange to convert B210LP(A) to match the Rate-of-rise detection: responds to greater than 15°F(8.3°C) B350LP(A) profile, or to convert older high-profile bases to low profile. per minute F110BP: Bulk pack of F110; package contains 15. Listings and Approvals F210: Replacement flange for B210LP(A)base Listings and approvals below apply to the H355(A) Series RA100Z(A): Remote LED annunciator.3—32 VDC.Mounts to detectors In some cases, certain modules may not be listed a U S. single-gang electrical box. For use with B501(A) and by certain approval agencies, or listing may be in process B210LP(A)bases only Consult factory for latest listing status. SMB600:Surface mounting kit • UL Listed:S2517. M02-04-00:Test magnet. • ULC Listed(models H355A, H355RA, H355HTA) M02-09-00:Test magnet with telescoping handle • CSFM approved.7270-0075:0195. XR2B: Detector removal tool Allows installation and/or • FM approved removal of detector heads from bases in high ceiling applica- tions Product Line Information XP-4: Extension pole for XR2B Comes in three 5-foot(1 524 NOTE:"A"suffix indicates ULC Listed model. m)sections. H355: Intelligent thermal sensor; 135°F(57°C);B210LP base T55-127-010: Detector removal tool without pole included. H355A: Same as H355 but with ULC Listing, B210LPA base included. H355R: Same as H355 with rate-of-rise feature; B210LP base included. H355RA: Same as H355R but with ULC Listing, B210LPA base included. H355HT: Intelligent fixed high-temperature thermal detector, 190°F(88°C);B210LP base included. H355HTA: Same as H355HT but with ULC Listing; B210LPA base included. Fire•Lite®Alarms is a registered trademark of Honeywell International Inc ©2013 by Honeywell International Inc All rights reserved Unauthorized use of this document is strictly prohibited This document is not intended to be used for installation purposes. IS® 9O®1 k We try to keep our product information up-to-date and accurate CERTIFIED. We cannot cover all specific applications or anticipate all requirements ENGINEERING&MANUFAC1IJAING All specifications are subject to change without notice QUALITY SYSTEMS Made in the U.S A For more information,contact Fire•Lite Alarms Phone (800)627-3473,FAX (877)699-4105 www.firelite corn Page 2 of 2—DF-523850•5/17/2013 DF-52013:D•E-100 BG-12LX et144 FIre•LITeALarms Addressable Manual Pull Station by Honeywell ,x, ';' �a v s z `; Ad.r SSabieiti x ICQ ,; r. 2 General The Fire.Lite BG-12LX is a state-of-the-art, dual-action (i.e., requires two motions to activate the station) pull station that ! 4-.0; , includes an addressable interface (mounted inside) for Fire•Lite's addressable fire alarm control panels (FACPs) Because the BG-12LX is addressable, the control panel can .'' display the exact location of the activated manual station.This "• leads fire personnel quickly to the location of the alarm. Features PULL DOWN' • Maintenance personnel can open station for inspection and •••: address setting without causing an alarm condition. • Built-in bicolor LED, which is visible through the handle of the station,flashes in normal operation and latches steadyN. red when in alarm. • Handle latches in down position and the word"ACTIVATED" ` • ,, appears to clearly indicate the station has been operated. • • • :- 45, a,. • Captive screw terminals wire-ready for easy connection tol SLC loop(accepts up to 12 AWG/3.25 mm2 wire). • ,� F1Y„ ITN Lc� + ofae e f ..° 1 t • Can be surface mounted (with SB-10 or SB-I/O) or semi- =: flush mounted. Semi-flush mount to a standard single- " gang,double-gang,or 4"(10.16 cm)square electrical box. , • Smooth dual-action design - • Meets ADAAG controls and operating mechanisms guide- lines LL (Section 4.1.3[13]); meets ADA requirement for 5 lb maximum activation force. • Highly visible usually needed for semi-flush mounting with 4" (10.16 cm) or • Attractive shape and textured finish. double-gang boxes(not with single-gang boxes) • Key reset. Operation • Includes Braille text on station handle. • Optional trim ring(BG12TR). Pushing in,then pulling down on the handle causes it to latch in the down/activated position Once latched,the word"ACTI- • Meets UL 38, Standard for Manually Actuated Signaling VATED" (in bright yellow) appears at the top of the handle, Boxes. while a portion of the handle protrudes from the bottom of the station.To reset the station,simply unlock the station with the Construction key and pull the door open.This action resets the handle;clos- Shell, door, and handle are molded of durable polycarbonate ing the door automatically resets the switch. material with a textured finish. Each manual station, on command from the control panel, sends data to the panel representing the state of the manual Specifications switch.Two rotary decimal switches allow address settings (1—159 with Breakaway Tab removed for MS-9600 Series, 1— • Shipping Weight:9.6 oz (272 15 g) 99 and MS-92000DLS, 1 —50 for MS-9050UD) • Normal operating voltage:24 VDC • Maximum SLC loop voltage:28.0 VDC. Architectural/Engineering • Maximum SLC standby current:375 NA. Specifications • Maximum SLC alarm current:5 mA. Manual Fire Alarm Stations shall be non-coded, with a key- • Temperature Range:32°F to 120°F(0°C to 49°C) operated reset lock in order that they may be tested, and so • Relative Humidity: 10%to 93%(noncondensing) designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key.An operated sta- • For use indoors in a dry location tion shall automatically condition itself so as to be visually detected as activated. Manual stations shall be constructed of Installation red-colored polycarbonate material with clearly visible operat- The BG-12LX will mount semi-flush into a single-gang,double- • instructions provided on the cover. The word FIRE shall • gang,or standard 4"(10.16 cm)square electrical outlet box,or appear on the front of the stations in white letters, 1 00 inches will surface mount to the model SB-10 or SB-I/O surface back- (2 54 cm) or larger. Stations shall be suitable for surface box. If the BG-12LX is being semi flush mounted, then the mounting on matching backbox SB-10 or SB-I/O;or semi-flush optional trim ring (BG12TR) may be used. The BG12TR is mounting on a standard single-gang, double-gang, or 4"(10.16 cm) square electrical box, and shall be installed DF-52013:D•4/13/2012—Page 1 of 2 within the limits defined by the Americans with Disabilities Act (ADA) or per national/local requirements Manual Stations shall be Underwriters Laboratories listed. Manual stations shall connect with two wires to one of the con- trol panel SLC loops. The manual station shall, on command from the control panel,send data to the panel representing the state of the manual switch Manual stations shall provide address setting by use of rotary decimal switches Product Line Information BG-12LX: Dual-action addressable pull station. Includes key locking feature. (Listed for Canadian and non-Canadian appli- cations.) SB-10:Surface backbox,metal SB-I/O:Surface backbox,plastic BG12TR:Optional trim ring. 17003:Keys,set of two. Agency Listings and Approvals In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in pro- cess.Consult factory for latest listing status • UUULC Listed: S711 (listed for Canadian and non-Cana- dian applications). • MEA:67-02-E • CS FM:7150-0075:0184. • FM Approved. Patented: U.S. Patent No. D428,351, 6,380,846; 6,314,772, 6,632,108 FireLite®Alarms®is a registered trademark of Honeywell International Inc ©2012 by Honeywell International Inc All rights reserved.Unauthorized use of this document is strictly prohibited 1So 9oo ■ This document is not intended to be used for installation purposes We try to keep our product information up-to-date and accurate • CERTIFIECI0 We cannot cover all specific applications or anticipate all requirements ENGINEERING&MANUFACTURING All specifications are subject to change without notice QUALITY SYSTEMS Made inthe US A For more information,contact Fire•Lite Alarms.Phone (800)627-3473,FAX (877)699-4105 www.firelite.com Page 2 of 2—DF-52013 D•4/13/2012 DF-60612:A•Al-10 Wheelock® ExcederTM r:70 FI e•LiTe°ALarnis Horns and Strobes by Honeywell °.�*�Aw.m"M,,;,,3 s, ' '•' Em �a" a16 ° al Devic-s' vkt4t„ ° F4, a'•11•IONE av 164 s '''',% Y „66A wrav- = A 66 466.a: ,a a_a°. General - The Wheelock@ ExcederTM Series of notification appliances feature a sleek modern design and numerous features includ- ing eight candela options in one appliance, low current draw, ° no tools needed for setting changes, 12/24 VDC operation, I r l ; universal mounting base and multiple mounting options. Models with an audible feature 3 sound settings (90, 95, 99 Wall dB).All switches to change settings can be set without the use , ;- • of a tool and are located behind the appliance to prevent tam- -77-----=-17; pering. Wall models feature voltage test points to take read- P "x,.. ; n q ins with a voltage meter for troubleshootingand AHJ r rccM " " ' ' inspection. v�' F"'"°>. Ceilin The Wheelock@ ExcederTM Series of wall and ceiling notifica- ;/r. sr. T -- tion appliances feature a Universal Mounting Base (UMB) designed to simplify the installation and testing of horns, "•. r, `''°''1 „` strobes,and combination horn strobes.The separate universal mounting base can be pre-wired to allow full testing of circuit wiring before the appliance is installed and the surface is fin- ished. It comes complete with a contact cover for protection against dirt,dust, paint and damage to the contacts The con- tact on tact cover also acts as a shunting device to allow pre-wire test General Notes ing for common wiring issues. The contact cover is polarized to prevent it from being installed • All candela ratings represent minimum effective strobe incorrectly and prevents the appliance from being installed intensity based on UL Standard 1971. while it is on the UMB.When the contact cover is removed the • Series Exceder Strobe products are Listed under UL Stan- circuit will show an open until the appliance is installed. The dards 1971 and 464 for indoor use with a temperature UMB allows for consistent installation and easy replacement of range of 32°F to 120°F(0°C to 49°C)and maximum humid- appliances if required.Wall models provide an optional locking ity of 93%(±2%)UL 464(85%UL 1971). screw for extra secure installation, while the ceiling models • Series Exceder horns are under UL Standard 464 for audi- provide a captive screw to prevent the screw from falling during ble signal appliances(Indoor use only). installation. • Product naming conventions: The Exceder line's model Features codes break down into easy-to-remember codes. HN = Horn, ST = Strobe, HS = Horn-strobe, C = Ceiling • Multiple voltages Mount,W=White,and R=Red.So"STRC"can be read as • Voltage test points for quick troubleshooting and easy spot- "Strobe, Red, Ceding-mount:'.,and "HSW"is"Horn-strobe, checking(wall models only) white,wall-mount" • 3 audible settings(90,95,99 dB) • Refer to your fire alarm panel or power supply manual when • 8 Candela settings calculating the number of devices allowed per circuit. —Wall-15/1575/30/75/95/110/135/185 Architects/Engineers Specifications —Ceiling-15,30,60,75,95,115, 150,177 The notification appliances shall be Wheelock Exceder Series • Finger-slide switches HS Audible Strobe appliances, Series ST Visual Strobe appli- • Sleek modern aesthetics ances and Series HN Audible appliances or approved equals. • Common base for wall and ceiling with 5 mounting options: The Series HS and ST Strobes shall be listed for UL Standard 1971 (Emergency Devices for the Hearing-Impaired)for Indoor —1-gang Fire Protection Service.The Series HS and HN Audibles shall —2-gang be UL Listed under Standard 464 (Fire Protective Signaling). —4 inch square All Series shall meet the requirements of FCC Part 15 Class B. —3.5 inch octagonal All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel —4 inch octagonal (FACP) with the ability to operate from 8 to 33 VDC. Indoor and Requirements wall models shall incorporate voltage test points for easy volt- Compatibilityage inspection. • Synchronize using Wheelock Sync Modules,or panels with The Series HS Audible Strobe and ST Strobe appliances shall built-in Wheelock patented sync protocol. produce a flash rate of one flash per second over the Regu- • Compatible with UL"Regulated Voltage"using filtered VDC lated Voltage Range and shall incorporate a Xenon flashtube or unfiltered VRMS input voltage enclosed in a rugged Lexan@ lens.The Series shall be of low • Strobes produce one flash per second over the Regulated current design.Where Multi-Candela appliances are specified, Voltage range. the strobe intensity shall have 8 field selectable settings at 15, DF-60612 A•05/03/2010—Page 1 of 2 15/75, 30, 75, 95, 110, 135, 185 candela for wall mount and shall been round and have a low profile with a diameter of 15, 30, 60, 75, 95, 115, 150, 177 candela for ceiling mount. 6 68" x 2 63" D Series HNC ceiling shall have a diameter of The selector switch for selecting the candela shall be tamper 6 68"x 1 50"D. resistant.The 15/75 candela strobe shall be specified when 15 SYNCHRONIZATION candela UL Standard 1971 Listing with 75 candela on-axis is required (e g.ADA compliance). Appliances with candela set- When synchronization is required,the appliance shall be corn- tangs shall show the candela selection in a visible location at all patible with Wheelockeis SM, DSM Sync Modules, Whee- times when installed. lock@ Power Supplies or other manufactureris panels with The audible shall have a minimum of three field selectable set- built-in Wheelock®Patented Sync Protocol The strobes shall tings for dBA levels and shall have a choice of continuous or not drift out of synchronization at any time during operation. If temporal(Code 3)audible outputs the sync protocol fails to operate, the strobe shall revert to a non-synchronized flash-rate and still maintain one flash per MOUNTING OPTIONS second over its Regulated Voltage Range.The appliance shall The Series HS Audible Strobe,ST Strobe and Series HN Audi- also be designed so that the audible signal may be silenced ble shall incorporate a patented Universal Mounting Base that while maintaining strobe activation when used with Whee shall allow mounting to a single-gang,double-gang,4"square, locks synchronization protocol. 3.5" octagonal, 4" octagonal or 100mm European type back Standards and Codes boxes Two wire appliance wiring shall be capable of directly connecting to the mounting base. Continuity checking of the Modules in this series comply with UL Standard 1971, UL entire NAC circuit prior to attaching any notification appliances Standard 464,California State Fire Marshal(CSFM),and ULC shall be allowed.Product shall come with contact cover to pro- tect contact springs Removal of an appliance shall result in a Agency Listings supervision fault condition by the Fire Alarm Control Panel These listings and approvals apply to the modules specified in (FACP).The mounting base shall be the same base among all this document.In some cases,certain modules or applications horn,strobe, horn strobe,wall and ceiling models.All notifica- may not be listed by certain approval agencies, or listing may tion appliances shall be backwards compatible. be in process.Consult factory for latest listing status. PHYSICAL SPECIFICATIONS • UL Listed:S5391 (Strobes),E5946(Horns,Horn/strobes). The Series HS and ST wall models shall have a low profile • ULC Listed measuring 5 24" H x 4.58" W x 2.19" D Series HN wall shall • CSFM Listed:7125-0785:168. measure 5.24"H x 4.58"W x 1 6"D.The Series HSC and STC Specification & Ordering Information Model Strobe Candela 12/24 VDC Mounting Options Horn Strobes HSR 15,15/75,30,75,95,110,135,185 X Universal Mounting Base HSW 15,15/75,30,75,95,110,135,185 X Universal Mounting Base HSRC 15,30,60,75,95,115,150,177 X Universal Mounting Base HSWC 15,30,60,75,95,115,150,177 X Universal Mounting Base Strobes STR 15,15/75,30,75,95,110,135,185 X Universal Mounting Base STW 15,15/75,30,75,95,110,135,185 X Universal Mounting Base STRC 15,30,60,75,95,115,150,177 X Universal Mounting Base STWC 15,30,60,75,95,115,150,177 X Universal Mounting Base Horns HNR - X Universal Mounting Base HNW - X Universal Mounting Base HNRC - X Universal Mounting Base HNWC - X Universal Mounting Base *12 VDC models feature 15 and 15/75 settings NOTE:Due to continuous development of Cooper Wheelock products,specifications and offenngs are sub- ject to change without notice in accordance with Cooper Wheelock Inc., dba Cooper Notification standard terms and conditions. Fire-Lite Alarms®is a registered trademark of Honeywell International Inc. Exceder is a trademark and Wheelock®is a registered trademark of Cooper Notification ©2010 by Honeywell International Inc All rights reserved Unauthorized use of this document is strictly prohibited This document is not intended to be used for installation purposes We try to keep our product information up-to-date and accurate We cannot cover all specific applications or anticipate all requirements. ro All specifications are subject to change without notice Made in the U S A For more information,contact Fire•Lite Alarms Phone.(800)627-3473,FAX (877)699-4105 www firelite corn Page 2 of 2-DF-60612.A•05/03/2010 DF-52121.E•E-325 MMF-300(A) Series, riCij Fire.LITeALermS MDF-300 Addressable Monitor Modules by Honeywell .: ,* m.,444,, ` :.,, ,A s,„. f,” ,nkg, --'n 4 d1'4ssable Devic General Four different monitor modules are available for Fire•Lite'sp..', intelligent control panels to suit a variety of applications.Moni- tor modules are used to supervise a circuit of dry-contact input i C? devices,such as conventional heat detectors and pull stations, "k s or monitor and power a circuit of two-wire smoke detectors ,-,q `‘,...'..,:i° ' (MMF-302(A)) N r. MMF-300(A)is a standard-sized module(typically mounts to a S2 w.a.tv , . ,,, 9iCi,°' 4" [10.16 cm] square box) that supervises either a Style Dun* 'Y, (Class A) oryB (Class B) circuit ofdry-contactin input ''•°°°"S' •<<.,r Stylery P x: devices �(°,•n•Px;.,"`".". PAT �P10 5312.3•9 . MMF-301(A)is a miniature monitor module a mere 1.3"(3 302 a,„ 4 – (' cm) H x 2 75"(6.985 cm)W x 0.65" (1 651 cm) D that super- 'f"; IMP 0 , tv vises a Style B(Class B)circuit ofd contact input devices Its f ., ,V',�, = " i P compact design allows the MMF-301(A) to be mounted in a , ffi , ";,;R ,,Fp , single-gang box behind the device it monitors ; - �,✓} _ MMF-302(A) is a standard-sized module used to monitor and .---‘ ','1:-',. supervise compatible two wire, 24 volt, smoke detectors on a _ '' Style D(Class A)or Style B(Class B)circuit. MDF-300(A)is a standard-sized dual monitor module used to MMF-300(A)(Type H) monitor and supervise two independent two-wire Style B (Class B) dry-contact initiating device circuits (IDCs) at two supervisory indication at the control panel Monitored circuit separate, consecutive addresses in intelligent, two-wire sys- may be wired as an NFPA Style B(Class B)or Style D(Class tems A) Initiating Device Circuit A 47K Ohm End-of-Line Resistor LiteSpeedT"' is a communication protocol developed by (provided)terminates the Style B circuit.No resistor is required Fire•Lite Engineering that greatly increases the speed of corn- for supervision of the Style D circuit munication between analog intelligent devices Intelligent MMF-300(A)OPERATION devices communicate in a grouped fashion. If one of the devices within the group has new information,the panel CPU Each MMF-300(A) uses one of the available module stops the group poll and concentrates on single points The addresses on an SLC loop It responds to regular polls from net effect is response speed greater than five times that of the control panel and reports its type and the status(open/nor- other communication protocols. mal/short) of its Initiating Device Circuit(IDC) A flashing LED indicates that the module is in communication with the control MMF-300(A) Monitor Module panel The LED latches steady on alarm (subject to current limitations on the loop). • Built-in type identification automatically identifies this device as a monitor module to the control panel MMF-300(A)SPECIFICATIONS • Powered directly by two-wire SLC loop. No additional Nominal operating voltage: 15 to 32 VDC power required Maximum current draw:5 0 mA(LED on) • High noise(EMF/RFI)immunity Average operating current: 375 pA (LED flashing), 1 corn- • SEMS screws with clamping plates for ease of wiring. munication every 5 seconds,47k EOL. • Direct-dial entry of address* 01 – 159 on MS-9600 series Maximum IDC wiring resistance: 1500 Ohms panels,01 –99 on other compatible systems • LED flashes during normal operation and latches on steady Maximum IDC Voltage: 11 Volts to indicate alarm. EOL resistance:47K Ohms. The MMF-300(A)Monitor Module is intended for use in intelli- Temperature range:32°F to 120°F(0°C to 49°C). gent,two-wire systems,where the individual address of each Humidity range: 10%to 93%noncondensing module is selected using the built-in rotary switches It pro- vides either a two-wire or four-wire fault-tolerant Initiating Dimensions: 4.5" (11 43 cm) high x 4" (10.16 cm) wide x Device Circuit (IDC) for normally-open-contact fire alarm and 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x supervisory devices. The module has a panel-controlled LED 2 125"(5.398 cm)deep box. indicator The MMF-300(A) can be used to replace M300(A) modules in existing systems. MMF-301(A) Mini Monitor Module MMF-300(A)APPLICATIONS • Built-in type identification automatically identifies this device • Use to monitor a zone of four-wire smoke detectors, manual as a monitor module to the panel. fire alarm pull stations, waterflow devices, or other normally- • Powered directly by two-wire SLC loop No additional open dry-contact alarm activation devices. May also be used power required. _ to monitor normally-open supervisory devices with special • High noise(EMF/RFI)immunity ----R,• rx.g. -- --7, -- m " r t. r .W , . *_", ., _ .. _. DF-52121 E•07/30/2015—Page 1 of 4 • Tinned,stripped leads for ease of wiring • Supervises IDC wiring and connection of external power • Direct-dial entry of address: 01 – 159 on MS-9600 series source panels,01–99 on other compatible systems • High noise(EMF/RFI)immunity • SEMS screws with clamping plates for ease of wiring ' 1415 0 1 ADDRESS 0 1 • Direct-dial entry entry of address 01 – 159 on MS-9600 13 2 2 series panels,01 –99 on other compatible systems 3 11 �, LOOP LED flashes during normal operation 101•�� 5 ,•�� 5 LED latches steady to indicate alarm on command from control panel 9 8 N 6 9 8 7 6 TENS ONES The MMF-302(A)Interface Module is intended for use in intelli- ( ) n i n gent, addressable systems, where the individual address of each module is selected using built-in rotary switches This module allows intelligent panels to interface and monitor two- wire conventional smoke detectors It transmits the status Y (normal, open, or alarm) of one full zone of conventional 0 _ W , Q detectors back to the control panel All two-wire detectors Lu being monitored must be UL compatible with the module The MMF-302(A) can be used to replace M302(A) modules in I I existing systems MMF 302(A)APPLICATIONS I I Use the MMF-302(A) to monitor a zone of two-wire smoke The MMF-301(A) Mini Monitor Module can be installed in a detectors The monitored circuit may be wired as an NFPA single-gang junction directly behind the monitored unit Its Style B(Class B)or Style D(Class A) Initiating Device Circuit small size and light weight allow it to be installed without rigid A 3 9 K Ohm End-of-Line Resistor (provided) terminates the mounting The MMF-301(A) is intended for use in intelligent, end of the Style B or D (class B or A) circuit (maximum IDC two-wire systems where the individual address of each module loop resistance is 25 Ohms) Install ELR across terminals 8 is selected using rotary switches It provides a two-wire initiat- and 9 for Style D application. ing device circuit for normally-open-contact fire alarm devices. The MMF-301(A)can be used to replace M301(A)modules in MMF-302(A)OPERATION existing systems Each MMF-302(A) uses one of the available module MMF-301(A)APPLICATIONS addresses on an SLC loop It responds to regular polls from the control panel and reports its type and the status(open/nor- Use to monitor a single device or a zone of four-wire smoke mal/short) of its Initiating Device Circuit(IDC) A flashing LED detectors, manual fire alarm pull stations, waterflow devices, indicates that the module is in communication with the control or other normally-open dry-contact devices May also be used panel The LED latches steady on alarm (subject to current to monitor normally-open supervisory devices with special limitations on the loop) supervisory indication at the control panel. Monitored circuit/ device is wired as an NFPA Style B(Class B) Initiating Device MMF-302(A)SPECIFICATIONS Circuit A 47K Ohm End-of-Line Resistor(provided)terminates Nominal operating voltage: 15 to 32 VDC. the circuit Maximum current draw:5 1 mA(LED on) MMF-301(A)OPERATION Maximum IDC wiring resistance:25 Ohms. Each MMF-301(A) uses one of the available module Average operating current: 270 pA, 1 communication and 1 addresses on an SLC loop. It responds to regular polls from LED flash every 5 seconds,3 9k eol the control panel and reports its type and the status(open/nor- mal/short)of its Initiating Device Circuit(IDC). EOL resistance:3 9K Ohms MMF-301(A)SPECIFICATIONS External supply voltage(between Terminals T10 and T11): • Nominal operating voltage: 15 to 32 VDC DC voltage 24 volts power limited • Average operating current: 350 pA, 1 communication every Ripple voltage.0 1 Vrms maximum 5 seconds, 47k EOL, 600 pA Max (Communicating, IDC • Current 90 mA per module maximum Shorted) Temperature range:32°F to 120°F(0°C to 49°C). Maximum IDC wiring resistance: 1500 Ohms Humidity range: 10%to 93%noncondensing. Maximum IDC Voltage: 11 Volts Dimensions: 4.5" (11 43 cm) high x 4" (10 16 cm) wide x Maximum IDC Current:450 pA 1 25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2 125"(5 398 cm)deep box EOL resistance:47K Ohms Temperature range:32°F to 120°F(0°C to 49°C). MDF-300(A) Dual Monitor Module Humidity range: 10%to 93%noncondensing The MDF-300(A) Dual Monitor Module is intended for use in Dimensions: 1 3" (3.302 cm) high x 2 75" (6 985 cm)wide x intelligent, two wire systems It provides two independent two- 0 65"(1 651 cm)deep. wire initiating device circuits(IDCs)at two separate,consecutive addresses It is capable of monitoring normally open contact fire Wire length:6"(15 24 cm)minimum alarm and supervisory devices The module has a single panel- controlled LED MMF-302(A) Interface Module • Supports compatible two-wire smoke detectors Page 2 of 4—DF-52121 E•07/30/2015 NOTE: The MDF-300(A)provides two Style 8(Class 8) IDC cir- MDF-300(A): Monitor module,dual,two independent Class B cults ONLY Style D(Class A) IDC circuits are NOT supported in circuits any application SMB500:Optional surface-mount backbox. MDF-300(A)SPECIFICATIONS NOTE: See installation instructions and refer to the SLC Wiring Normal operating voltage range: 15 to 32 VDC. Manual,PN 51309 Maximum current draw:6 4 mA(LED on). Average operating current:750 pA(LED flashing). Architects/Engineers Specifications Maximum IDC wiring resistance: 1,500 Ohms. Specifications of these devices and all FireLite products are available from FireLite Maximum IDC Voltage: 11 Volts. Maximum IDC Current:240 pA EOL resistance:47K Ohms Temperature range:32°to 120°F(0°to 49°C) Humidity range: 10%to 93%(non-condensing). Dimensions: 4 5" (11 43 cm) high x 4" (10 16 cm) wide x 1 25" (3 175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125"(5.398 cm)deep box MDF-300(A)AUTOMATIC ADDRESSING The MDF-300(A) automatically assigns itself to two address- able points, starting with the original address. For example, if the MDF-300(A) is set to address "26", then it will automati- cally assign itself to addresses"26"and"27" NOTE:"Ones"addresses on the MDF-300(A)are 0, 2, 4, 6, or 8 only. Terminals 6 and 7 use the first address, and terminals 8 and 9 use the second address CAUTION: Avoid duplicating addresses on the system Installation MMF-300(A), MMF-302(A), and MDF-300(A) modules mount directly to a standard 4"(10.16 cm)square,2.125"(5 398 cm) deep, electrical box They may also be mounted to the SMB500 surface-mount box. Mounting hardware and installa- tion instructions are provided with each module. All wiring must conform to applicable local codes,ordinances,and regu- lations These modules are intended for power-limited wiring only. The MMF-301(A)module is intended to be wired and mounted without rigid connections inside a standard electrical box. All wiring must conform to applicable local codes, ordinances, and regulations Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status • UL:S2424. • ULC: S2424 • FM Approved. • CSFM:7300-0075:0185. • MEA:72-01-E. Product Line Information NOTE:"A"suffix indicates ULC-listed model MMF-300(A):Monitor module MMF-301(A):Monitor module,miniature. MMF-302(A):Monitor module,two-wire detectors 0.e'MMR�M�Iea'ndww�ww�L�YnA._�ffiVw9wv ^"wmu.�Pc: ouw.gw,emm,cr^„''.a,-"-"a�w.. ,�m�s• WdPX.:_. _- - yllT RW�F. --^-lau.wgmm;AwntwMAMur:.owowv�a.. ->euwAm•T.^^:•N�vmm�.vrcr wwrwkwwa�wus» DF-52121 E•07/30/2015—Page 3 of 4 i Fire Lite®is a registered trademark and LiteSpeedTM and FveWatchTM are trademarks of Honeywell International Inc ©2015 by Honeywell International Inc All rights reserved Unauthonzed use of this document is strictly prohibited Iso �oo� This document is not intended to be used for installation purposes We try to keep our product information up-to-date and accurate CERT F'l E We cannot cover all specific applications or anticipate all requirements 8YtINEMINS 8 MANUFACTURING All specifications are subject to change without notice QUALITY SYSTEMS For more information,contact Fire•Lite Alarms Phone (800)627-3473,FAX (877)699-4105 www firelite corn Page 4 of 4—DF-52121 E•07/30/2015 € I — I I� I I •, 1 I 1 111 "t,ll,:,:-p:#..� n' '.1: s�. I ! i 1 I { 3'2 .R CRAWL SPACE , ,/� �' — --- ,•-_-.4. LIVING ROOM 1 '1 BEDROOM 1 1 — F.1 E - 1._.. ( ❑, I ❑ Q 1 .- SHED ROOF -. I I_. cLosEr i N 1.-, - 4C (�6C N N 1 ^ Ns .r I I\.- C -�2� C 23 _ 7 7\.c' ( 0 24 W 4� ( �� �'L�.ti 2"UP ♦�, III 05 1 0� CLCI r-.M .. _ 1 �� + 32 . 2"DN / L I— 2r UP m z 1 ;r -I. r :_�—a.p r_.Y._.____11,..,,,-:2:- _ __ 'T772__=4, - --k� 73.0 3 ( 720 3 2.1.z- 21a Q BEDROOM 0-1'z 1-5 . .- . _... >r, �! 0-111z _ _ / I I/ / I III I I s ► 8-1312 OO 9-0 I 5-1 �. .._.._..._.... .._ 1,z . ... // 1 5-8 8-11': i N" CL IIL CL ) 7-7 2�z ❑ ;� 0-3 ❑� 212 L' . 2" WILKINS MODEL I 21-6 6-81z0 a { ( I I ( N . . o-7 r z s o` 0_6 1 975XL2(LEAD FREE) r, F.-, BA�QiENT^ i _ 1 2 ❑ _ - u 2 2 1: ROOF N / 10 2f r I > > 1E FOYER1 13-0 0-6 1 ro i I' y I I` N 1 11 1-5 KITCHEN R SYSTEM RISERIjIt2t v..__._.-..... p-1 I I k�_ 0-2 z BEDROOM _ DINING KITCHEN I�5C � �7�� A'J�1.3 ) `?" �> �: ' -t �19 )N � B/ MENT � � - �\ 0 _ 6 I 2 DINING/KITCHEN ,It 15 / ( './., j.� �•/ STORAGE°91i - LAUNDRY r 6-3 �,,„ 1-1 , LIVING ROOM ❑ � ilii_______._....__________ h �qk 2 i U Q rH^8 �2}7 _._ 2tz._«r- 2}s- —2a2 - ❑ SINGLE INLET D.C. ROOF t ❑ 72 0 ; , 3 -©' iz C BATHROOMyQ 7 I — — '6 = 6-5tz 4-01z 4-11�z a ri- 0 2rI z3-93-9 6 .. / .. 1i r'r,`) .__._.___..__-_.__ _ ❑ 2 `� EXISTING ROOF a0-1/ '2tz ♦ ♦�♦ ALLW 1 ) 20 ,� 2 3 0 c° 11 _..___�__ _ 3-312 68. ''''-iii3 45.-0.1;—.....3 yl 1 i 10_� ., \ . BR OI_ ❑ N�' 11 1 cv p o �ti 25 ; ® ,, jz., ,ry L(3�N ..T 7�O q�5 "tz (+11i _ 2 } _u ! ROOF '� j/� 1�. �' - 1 HALL 1 N 1 1 2, , ♦ 1, C 1 32 3. M M KITCHEN s 0 3-2 4-2 1 14-5 �� 5-11 7-5 z 1 7-7 z 1 7-6 T:...i t 2 :...._...._:..: 1 r2 . -.:._. 1_-;:.:. ;:=c .- :.1 t 2 _..........._..1 z ...._... ._..1 t z.._._......,.,, ............. __=4==4 ":...:-.......:.....5....612::.=_-- - ---_-......_5,-.&t z:. �_. .. — ❑ N I 0-21z i-1'z _ 0-11tz �2,z PORCH I 127.0 3 i�� SEFJIENT 2'� 0 BR �._.,_._. 5-0 9-1 z /� 7-8 -7 8-9 I ,� 1` lr LLL" { z .\/ 1,�a ( p,3t 6.0 3/I /� l'911\,..„2:1,4 o a BEDROOM i �, o,Cti p�`1 1 RI / DINING ROOM {' Ns L d { BR I ,2 / , I 1 I I , BEDROOM N o 1-4'z . :N ® IP. �• N�o�ti - - » , i ❑ I I I _-1t zes, {_ o, BEDROOM BEDROOM ► �� 2C� ) p t _ _._...._.._.. 1 .._ ❑ BR I BEDROOM BA _ ENT ;� I) I �N ti 2-21 3-5Fr � ` �„ ::'% ''' ~ .% W____._,____ ® c� , aI ()-311 -:: :AL:i1!--iii s CRAWL SPACE - ,ry I ^ ,~ ❑ 1 ❑ `� `� 1:11 I 0-21s ROOF / 1 1 _._.rt r 1tz — ��IALL B ' 6 ` / a 127.0 - LIVING ROOM I I _ t ', . ,_ _ -3 1r .1 1 / q ? r �� 1t " .I EXISTING CHIMNEY 0-4 ❑ ❑ —4, !!!`��-'----ccdll f! a\R1 a I -/ CL -31z�013+ 11_it T `�" �2 1 1l I 31 yyy��� i CL — I �.6 7 .1- 1/I-2, �`L tz 1tz .1tz. 1tz0-3tzA s .1 ti I �� CLOSET in -=7 3 -9- �z s f i HALL 1-6 t A KITCHEN I 256.! - ❑ _ P� ?� E-32/ I I ( ❑ I i 1=,i © 1 t z FOYER : v 1 1'a....... .ti E-------=,--11 © ,..'972 C p`1 { _"— p 1 2 '�,'r'� rf _.._...� 1-Qip - >-a a�9; 14 °° — ..... __—"'` 0-6 1� � 1 'I 11 CL❑I I�tI U LIVING ROOMI z' I LfiI _ --:.i s 5,7_ _ 3-Dtz_ -� 0-34a 1 t z I77):1.41wr, I R. 1 3 �' N _ `NAL �" DINING ROOM N 5=5' .' SET I ( 1 I ��j- 11 ❑ ❑ 1 ❑ 1 _ I NJ4• 127.0 B ( 14_1_. _ ..__._ ..�I € ?- 1 ) 2-1 O -CL ? h - I . t KITCHENS .... __..._ _____ awe,....._. �� , ,---,--- , --256 96Lr2 2 1 j ,c a_._ ..� 1'4� I �` i o ... I I ( I -1 , 0-3rz11 ; i - - ❑ 8- STAIRSG it I ` '( INSPECTORS TEST OUTLET CL L _- 0 1 CRAWL SPACE LIVING ROOM (1B \ STAFF '� INSPECTORS TEST VALVE r� 4A ‘5-1 1 � _ 0-212 1 1 ❑ L _ - ❑ ❑ I 1+11' ,��o 218 ♦ 4-2+z • 11 I. BEDROOM • 1` :-"� • 256,8_I 2 I +20'256 0 1 s Io' �j 1 lr ..,......,-.....,...,.....,...f. t i FIRE PLACE 0-312 { HYDRAULIC REMOTE AREA---' .........__.._._..____..__.._.____._._._..-._-- ..__._ l I I .05 GPM/SF OVER 4 MOST DEMANDING QUICK RESPONSE I I RESIDENTIAL SPRINKLERS AS PER NFPA 13R, 2007. ' HYDRAULIC REMOTE AREA (SECTION 6.8.1.2) )4"K=4.2 155' e' 05 GPM/SF OVER 4 MOST DEMANDING QUICK RESPONSE PORCH RESIDENTIAL SPRINKLERS AS PER NFPA 13R, 2007. / DECK ABOVE (SECTION 6.8.1.2) )c K=4.2 155' II t/ ROOF V......................................L _ i c - Lil 47A, . 40,i..:4 ' '��' � SECOND FLOOR FIRE SPRINKLER PLAN " ���i,�,� " �1 FIRST FLOOR FIRE SPRINKLER PLAN BASEMENT FIRE SPRINKLER PLAN �► 4 �� SCALE: 1/8" = 1'-0" `"O SCALE: 1/8" = 1-O" �- _ '`, SCALE: 1/8" = 1'-0" \‘A1.1OP fiAr- A 1I SPRINKLER HEAD LEGEND SYM CNT POSITION FINISH TEMP K NPT SIN MFG. MODEL# <1 78 SIDE WHITE 155 4.20 1/2" TY1334 TYCO LFII 0 18 UPR +hrti-iEfrAS 135 5.60 1/2" TY3105 TYCO TY-Fa SPRINKLER NOTES 1. SPRINKLER SYSTEM IS DESIGNED IN ACCORDANCE WITH NFPA 13R 2007, 2.ATTIC IS NOT TO BE USED FOR STORAGE AND SPRINKLERS ARE OMITTED IN ACCORDANCI • WITH NFPA 13R 2007 SECTION 8.9.6 3. SPRINKLER HEADS SHALL CLEAR LIGHTING FIXTURES, BEAMS, ETC. SIDEWALL HEADS SHALL BE POSITIONED SO THAT DEFLECTORS ARE MIN.4"AND MAX.6"FROM ' ,°�° . ° SW -� SPRK CEILING. SPRK � ` MAIN Q SOFFIT V 4.ALL PIPING SHALL BE STANDARD WEIGHT STEEL,COPPER OR CPVC. Q LIVING ROOM BEDROOM CL DINING ROOM KITCHEN HALL BEDROOM 5. CONTRACTOR SHALL FURNISH AND INSTALL ADDITIONAL PIPING INCLUDING DROPS, O 'Pr IF NECESSARY TO ATTAIN CLEARANCES AT NO ADDITIONAL COST. U LOCATION OF 2" 4" PLYWOOD 6. NEW UNDERGROUND WATER SERVICE SHALL COMPLY WITH LOCAL WATER AUTHORITY S REDUCED PRESSURE I REQUIREMENTS WITH REGARD TO MATERIAL, MIN.COVERAGE, INSTALLATION PRINCIPLE REQUIREMENTS ETC. 7. NO WORK SHALL COMMENCE PRIOR TO OBTAINING ALL NECESSARY APPROVALS FROM SINGLE 1 " o LOCAL WATER AUTHORITIES HAVING JURISDICTION. I INLET F.D.C. KITCHEN 1" DINING ROOM KITCHEN BEDROOM BATHROOM BEDROOM PORCH —NEW 2"K-COOPER - 8. CONTRACTOR SHALL FILE FOR FIRE LINE TAP WITH LOCAL WATER COMPANY. HYDRANT FLOW INFO. /14,1/N eq Y . FIRE SERVICE 12"JOISTS N 9. GENERAL CONTRACTOR SHALL PROVIDE SOFFITS FOR SPRINKLER LINES WHERE DATE: 07 02-15 �//e REQUIRED. ALL PIPES ARE TO RUN CONCEALED. STATIC: 73 PSI RD . ° RESIDUAL: 46 PSI , 10. NEW SPRINKLER SYSTEM SHALL BE TIED INTO FIRE ALARM SYSTEM WITH REQUIRED FLOW: 2173 GPM TAMPER SWITCH AND WATER FLOW SWITCH. BY:SCWA o BASEMENT CRAWL SPACE �Q EXISTING PUBLIC N WATER MAIN Q CHIMNEY /1`� �'\ °) 12" FOOLING w `O 1- E SITE PLAN _ Q Li NI'` O NTS 8" CONCRETE i`t BULIDING SECTION A s SLAB CEILING- ' S s'��ea,:�;a'*t nr= -,� 3;.(_. a,®�..-,� TO SYSTEM . ^AT, - _ .''..t;J �.P '' ` (:�4_eC C;l . . .- l '.' , H ALL C1ODFS OF .,� NEvI, Yv,,1( STATE & TOWN CODES /� / ��///// �. °�, [iY:.,_-(- _�- AS P;EQUIR DAN CONDITIONS 1 ` l :, ,,,FY BUILDING C ' ',r1 MENT AT OF CHECK 'xv VAVLE SPRINKLER 2 PIECE -11.02 8 AM TO 4 PM FOR THE SC'JTHO n?0'f"I'NL3A TYCO RISER�IANIFIXD w/ 1 ff 1 , 1`,; CJAII G INSPECTIONS: ' Iz1 IN A svTESTTCH _,_;mo i 1� ESCHUTCHEON r L,1r POURED EQ I E nI iTi i E ,,RD (t)DRAIN AND TEST {'G.J 'OF i 101 - TWO REQUIRED (� suREcwc \; I " e9 - FOR 1 OURED CONCRETE _ _..�..��A._, .. :,._ ;��5 3 PRES S DN BODY IL (+1�� c;� 1� SINGLE INLET ROT:',H FRAMING G &1 PLUM2ING c _ ®a 2'BurmmAu.vA.wi TAMPER �. fl I / I . sw. 0,,,I$ FD CONN_ _ f U PENDENT SPRINKLER 4. FINALIA`ICONSTRUCTION MUST l \ y• ° Da TYPICAL PENDENT SPRINKLER RE. COMPLETE FOR C.O. .... elf J ALL n Tr:.. ,. PREFER. FROM REMOTE WITH ESCUTCHEONC,.NS.e UC T la\I SHALL MEET THE ELECT CAL BRANCH LINE REQUIREMENTS OF THE CODES OF NEW RED PIPE \ YORK STATE. NOT RESPONSIBLE FOR I �' ��` 2" WILKINS MODEL N 975XL2 (LEAD FREE) WALN DESIGN OR CONSTRUCTION ERRORS. 2ff a► ` 2ff ,n1" TEST VA. IN WP°5\10‘.1\-- ,r� rd��.!- ACCESSIBLE LOCATION OC ` ,�,1� I z FIRE SPRINKLER FIRE INSPECTION \SI1/40 C� �� • �.-� SUPPORTS 4" DRAIN W/ 2•4- C‘') MAIN IN SOFFIT REQUIRED BEFORE ����'C\�Q� v� SCREEN & �t OPENING ek OC ' DRAFT v N 4„ STOP A _ ELL W/ CORROSION RESISTANT �I�'- OUTLET EQUAL TO A SPRINKLE f -�,!,.i... 1 OW/\ DRAINAGE TO BE 111 FIRST FLOOR -- _ BEDROOM POSITIVE WITH EFFLUENT d - z ' GRADE VISIBLE —__ ___ —.._.._....____.___ ;II-n-11 SIDEWALL SPRINKLER 11111111=1/A1 l , I---- BK FIRE SUPPRESSION & F.R.E.E. SECURITY SYSTEMS I.Ii.i1u.l=irF, HEAD „ -D 9625 MAIN BAYVIEW RD 1 11.11.11.11 .,,......" \�.J414O11_ WET PIPE INSPECTORS TESTii! e� r A DIVISION OF EMDI LTD. N tIC=.1�- Y2" GYP BD.-- NEW 2 K-COPPER 1- TAPED AND .....................8_-_..M X, 44.,- ",'�'��iir��o� ' SOUTHOLD, NY, 11971 r,111 FIRE SPRINKLER MAIN j / ei- A� - 826 SUFFOLK AVE. BRENTWOOD, SPACKLED � � N.Y. -- .7.>,\ Imo, PH#(631 )273-2010 FAX(631 )273-2939 G � s,. FIRE SPRINKLER PLAN LICENSE SCALE PIPE SUPPORT ATTACHED TO STRUCTURE i L # ' ~ 42815—RP AS NOTED o. 1°� t� SECTION OF FIRE TYP . SOFFIT DETAIL °�r,� S0.E�` NO. REVISIONS _ DATE BY CONTACT PERSON FILE 9625 MAIN SPRINKLER SERVICE NTS s "" KEVIN KAMM BAYVIEW .dwg DRAWN JOB # DWG. # FRANK RESTITUTO, ARCH. BY RF 18 CRABAPPLE LANE DATE COMMACK, N.Y. 11725 06/22/15 S P - 1 --a 1...-.--..... . I iI I I I I I 1 r-_-1I I i I Jf '1- ,n 112 _I 1 1 1 I CRAWL SPACE _ 10.S_-b 0-- I t 3 LIVING ROOM i BEDROOM 4104 _ -� i I c��osel- v1 `� I ❑I i 1+E 1'2 SHED ROOF O I I6t 112 ' I !„ „ I 3-012 3-8'v. �, H r=4-1/1 1 t z �� ^ �v i.� 1 i Sts • �A3; 112 �,ti _ '� I I (10 i / 0-5 I �`o a d b •�l 0-8 i ,� CIL] �r, k•- 89-.12 V�1 o �{ II i _ r 4--- _ _� >oC r I ,_a.___ ® i i -:. 1 g ___iT12 �.., a� ` 11s •-•1413 . 1 1'2 1 I r i-f-ffI i BEDROOM + 1-5 ( 7 1 1 00 0-11z112 IiaLas- 12 7-O+i 10-0 �b 5-1 8z I I 1I 1NV 1 .7 ^ L- '� 0-3 ❑ 0-3 KI FR 10-0 1f-0 1 6-8 2 iii 1 z r +IN I Ij N N� N i I i t 0-6 � �� 2" WILKINS MODEL 9-0 I BASOv1ENT T 1 2 31x 1 w `�' I J ❑z 11 �' s -� 112 1tz 975XL2U(LEAD EE) ROOF r� i rn ]-10 I i n 112 i .r .I FOYER " 13 20 _ '..I t r, 11 N* 1 I ' 2 11 '12 112 N 112 '0-71 t 2 I I 11-5'„ 0-6 :N �Q 1 11 I t S RAGE o I-112-37 II - KITCHEN R SYSTEM RISER { K4A� ii R,DN 1-111 19121 _3=1131x----- 1}+z= �8!2v tz___ az _ 1tz ), a BEDROOM ut 1 i 0-4 - �� 1 tt © 1'2 1 DINING/KITCHEN (E2 I I i �._3- z 1 2-10 _112 I , I . 7-8 z 1 6-3 11-SINGLE .1 1ctf _ �, LIVING ROOM ❑ i _ _ u _ ¶44 11. ---112 412 1Fz - 3-1012 .1- 8-ll+s �.1 ' 1tz I- 1t2 LAUNDRY 3 ;^�I ROOF � 4 I 1 11z 11+z 1+z '_- 10(" -6 0-8110EXISTING ROOF N INLET F.D.C. i . 9-81x 7-312 4-0123-5 -61z BATHROOM g---....„, o `� ❑I 3-9 3-31s- I 5-5+2 7, I HALLWAY I „ 7 ® 4,0 s _ II I 1 1 'T1 z - :• ? • ,I BASEMENTBR O II 3-9 1 !� o 1 N „ ;�, 112 El FIT .- b ` `V 0-4 0-4 1-3 1 r N^ JI b (- �+ 1-112 \ J ���1 6-4 3-111z 9-9 -�� 1 -�I- 11 tr- z f ....... * J' - -7+. 7-._......_N ROOF « 4� 1 b �� ti , \3A� }}y// -1- -�t�+ 1112 7-2 _. _ 1 (�( \ / 2, �� 8-0 0 5-11 11' 11 z i O PORCH �'• - i()--E}- -'1 1'z 2 i 1y1,I SEMENT I- - 110 1 ^ �',-' K❑ITCHEN I i w HALL 1141�,018-1112 0._1 . 1/ 1 Q BEDROOMI O F:. I ► I 9-10: /-1 t I 11z DINING ROOM ( t BEDROO Jr_o-"em_ 13 N BEDROOM s = 1 ' 1tz r� M _® I 1-8 Q -11°6 i 1 " 4-31 -. __..+z - BEDROOM 1 4e� m m I 3-7'21-F-NFI 2A BASEMENT I ( A4 N 4 B V 0 00-2 5-71 „ r,�N 11 i N to ® t t „ o .A--6 1 ❑ ❑ HALO 1 0 BEDROOM 8 4 CRAWL SPACE )� i 1 ` 1 _ N o 1 1l (4ti i I �� r_-1. 2 1 5s�b N b 2 c� t h a ❑1 0-2'2 ROOF EXISTING CHIMNEY L.-1-7-1 LIVING ROOM0141it 112 , (" c ► Ljt. _a - t v - t ri mm R� ALL U a 3 +.�2 _ 1 �E 1 1 1 z t .� _A 121 1 e I ►i i BR I 4,i4 5-9 tI CL 1121:1 4" CL134121 1� t t N z 1 z �q z -f: .._ .. �6 1 1 �`' ►1 A �2,IX rt T 1 0-9 CL-+ '- t ♦_ t a a a - _13A z 1 i - ❑ 1 z 1 ¢ 1 z- -1 z- LIVING ROOM 256:C21 2 , 2-61: 4-7 35 _4-i 6 =g t 1 o e I �`! KIT❑CHE i ❑ `N1 6 1:171 i 2-7_a 3-_..._ -9- 6' la ❑ 2-012 I '� 1 ❑ N 1.!' HALL i , t_2t1 CLOSET a t 1CI I R ? - 1 / -----:2-2 �W. .'-i I ,. ❑ 112 t� 1 Nr-r---'-j. ')..'--1'3: g" «. 1 136) I ''2 ,D1. 1 .!' © F'� = CL j 1 A Qat I i I cl I �1 t O x7- uS U P 0-4 t I t g. 0-6 ( ,o, r +z❑ t 1 -- �-� 112, `- t HALL 1-10 +�. 5-2+2-- t CI ( ""1 112 11 11 z ` 1-5 1 I I a %4c�` *\d __ _ 1 DININGROOM 1 N 0-4 1 1 1-. i EXISTING 5-NAIR X256.4::: ir_4.7112:4286_:_;:t © 1 © i N? I CLOSET 109 wt I I I LP I - �„ _ - 1 -4pCL NS!� +- ---- L14V1 I ) 2-1ti / I (' CLI I 1t 2 ix KITCHEN - 1 ;.t.2 b2_.. - - .. _:I ( I1 .� IL /Nf ri- o� s i ZDRAULIC __' .2558 5 11 ` -1,7,,,,; 5 4-l+x _- 1 C i ® 1 EXISTING I I I I LJ 11 t CAP t t ' 1-5+: STAIRS L___J I I I; i , ?� 112 L J LIVING ROOM I STAFFI 1 I 1 CRAWL SPACE i I ►1 . 1-2 z I_ -1 _ L ElEl1 0-21 z --� �, ii 1 I 1 - 'f :„ BEDROOM ------ 71 1 fl 11 REMOTE AREA 2-1 E ► .05 GPM/SF OVER 4 MOST DEMANDING QUICK RESPONSE - STORAGE ► ' +20' w i k INSPECTORS TEST OUTLET . 1 I RESIDENTIAL SPRINKLERS AS PER NEPA 13R, 2007. 0 .t2 FIRE PLACE 0-4 + 1 -�' (SECTION 6.8.1.2) X�'K=4.2 155' 1 I i I 3 moo* NSPECTORS TEST VALVE �_.._--- -4-----)I I I HYDRAULIC REMOTE AREA - Ii .05 GPM/SF OVER 4 MOST DEMANDING QUICK RESPONSE i RESIDENTIAL SPRINKLERS AS PER NFPA 13R, 2007. IL FIJ (SECTION 6.8.1.2) Xz'K=4.2 155' n DECK ABOVE PORCH ROOF (I)' ,-,_. Er „Th, L ,- -,- i H W ,moi'WI:- ,L4.1 ,,��'�i�� 1)-041.--‘ 'i� - - SECOND FLOOR FIRE SPRINKLER PLAN O - >n BASEMENT FIRE SPRINKLER PLAN u2 FIRST FLOOR FIRE SPRINKLER PLAN �� 'z' �� .� SCALE: 1/8" = 1'-0" Z V� •% SCALE: 1/8" = 1'-O" `� �•� SCALE: 1/8" = 1'-0" 1,r ti' SPRINKLER HEAD LEGEND SYM CNT POSITION FINISH TEMP K NPT SIN MFG. MODEL# d 80 SIDE WHITE 155 4.20 1/2" TY1334 TYCO LFII X 21 UPR BRASS 135 5.60 1/2" TY3131 TYCO TY-FRB SPRINKLER NOTES 1. SPRINKLER SYSTEM IS DESIGNED IN ACCORDANCE WITH NFPA 13R 2007. 2.ATTIC IS NOT TO BE USED FOR STORAGE AND SPRINKLERS ARE OMITTED IN ACCORDANCI WITH NFPA 13R 2007 SECTION 8.9.6 3. SPRINKLER HEADS SHALL CLEAR LIGHTING FIXTURES, BEAMS,ETC. SIDEWALL HEADS SHALL BE POSITIONED SO THAT DEFLECTORS ARE MIN.4"AND MAX.6"FROM Q 'Lli°J' °1' s.w ^\8MARN CEILING. Ct- SPRK ' V SOFFIT 4.ALL PIPING SHALL BE STANDARD WEIGHT STEEL,COPPER OR CPVC. Q D LIVING ROOM BEDROOM CL DINING ROOM KITCHEN HALL BEDROOM Ct `° 5. CONTRACTOR SHALL FURNISH AND INSTALL ADDITIONAL PIPING INCLUDING DROPS, IF NECESSARY TO ATTAIN CLEARANCES AT NO ADDITIONAL COST. I- (..)10 Orr / , 4" PLYWOOD y LOCATION OF 2" 6. NEW UNDERGROUND WATER SERVICE SHALL COMPLY WITH LOCAL WATER AUTHORITY REDUCED PRESSURE PRINCIPLE '� I REQUIREMENTS REQUIREMENTS WITHETC.REGARD TO MATERIAL, MIN.COVERAGE, INSTALLATION '� 1 7. NO WORK SHALL COMMENCE PRIOR TO OBTAINING ALL NECESSARY APPROVALS FROM SINGLE 13" , ` INLET F.D.C. KITCHEN _coDINING ROOM KITCHEN BEDROOM BATHROOM BEDROOM PORCH LOCAL WATER AUTHORITIES HAVING JURISDICTION. 12" FLOOR 8. CONTRACTOR SHALL FILE FOR FIRE LINE TAP WITH LOCAL WATER COMPANY. '_�-NEW 2"K-COOPER HYDRANT FLOW INFO. M,q/N eq \,, FIRE SERVICE JOISTS 9. GENERAL CONTRACTOR SHALL PROVIDE SOFFITS FOR SPRINKLER LINES WHERE DATE: 07 02-15 //� REQUIRED. ALL PIPES ARE TO RUN CONCEALED. STATIC: 73 PSI TAX MAP # INFO. w RD �° RESIDUAL: 46 PSI SECTION: 88 , 10. NEW SPRINKLER SYSTEM SHALL BE TIED INTO FIRE ALARM SYSTEM WITH REQUIRED FLOW: 2173 GPM BLOCK: 3 TAMPER SWITCH AND WATER FLOW SWITCH. BY:SCWA LOT: 23.1 o BASEMENT CRAWL SPACE ba EXISTING PUBLIC N WATER MAIN CHIMNEY 12" FOOTING CO 0 w ,t E SITE PLAN Q0 1\.O%� NTS \� Iii ��� �c 8' CONCRETE s `t BULIDING SECTION A SLAB CEILING- - TO SYSTEM` 1 }" CHECK �/ / 4-2 VAVLE // _. TYCO RISER Mr=w/ 1 3" I 13" (2)FLOWAIN D1EST \SIM _ D----n------ti - SPRINKLER 2 PIECE (11 (3(') BOD ESCHUTCHEON di4 „ 1}" SINGLE INLET \j-/ / _rt_A L vti m/TAMPER •. FD CONN. W. \ ' .hhi : 1251 "luca : _ 0,,, , , \ VPENDENT SPRINKLER ;T : "• Rhe 2" WILKINS MODELIL iRi MI 975XL2U (LEAD FREE) iv ] TYPICAL PENDENT SPRINKLER 2 - PREFER. FROM REMOTE WITH ESCUTCHEON ` 2" •,,, BRANCH LINE co PIPE +411Th . IN �, WALL _�.- - SUPPORTS `/ 4' DRAIN W/ 1" TEST VA. IN FaC SCREEN do ACCESSIBLE LOCATION DRAFT STOP N o 4„ A - _ z FIRE SPRINKLER MAIN IN SOFFIT z DRNINAGE TO BE PO,3I11VE WITH EFFLUENT j _ r ' A IMA11110.111=11 8 - BEDROOM GRADE co �48� -I :11:=11:=II=.�" ELL W/ CORROSION RESISTANT '•, 0 11=11=1_f- OUTLET EQUAL TO A SPRINKLER f ' ,' i'�I� i��2 f 1=11=11.- N Il=tl=U _ Til 1:11:11:=1r A 3" PVC SLEEVE ! 1111111111/1111BK FIRE SUPPRESSION SIDEWALL .4w° ~ F.R.E.E. RESSION & WET PIPE INSPECTORS TEST `�o�EDr�� wSECURITY SYSTEMS /C., fk. J� 9625 MAIN BAYVIEW RD BASEMENT Y2" GYP AND 8" M,�._X l - � t t��G��� ct NY, 11971 A DIVISION OF EMDI LTD. SPACKLED / ,.,-2>.:445,,,,,,,° t> �F w SOUTHOLD, 826 SUFFOLK AVE. BRENTWOOD, N.Y. NEW 2" K-COPPERisi ' �T- FIRE SPRINKLER MAIN isw PH#(631 )273-2010 FAX(631)273-2939 5 PIPE SUPPORT ATTACHED TO STRUCTURE ,�'s ' ' ;: 1- FIRE SPRINKLER PLAN LICENSE # SCALE r�� �o. 10.1.1 �a� .' 42815-RP AS NOTED TYP . SOFFIT DETAIL / °f ria ST NO. REVISIONS DATE BY CONTACT PERSON FILE 9625 MAIN SECTION OF FIRE NTS A AS-BUILTS 12/1/15 RF KEVIN KAMM BAYVIEW .dwg DRAWN JOB # DWG. # SPRINKLER SERVICE FRANK RESTITUTO, ARCH. BY RF 18 CRABAPPLE LANE DATE COMMACK, N.Y. 11725 06/22/15 SP - 1 i 1I � � LL v Q LEGEND .. _ e- —.. m s- N < O Q H Imoue_ , QUANTITIES QTY SYMBOL DESCRIPTION CAT. NO. CRAWL SPACE € 0 1 0 0 1 FACP FIRE ALARM CONTROL PANEL FIRE-LITE 92000DLS ani I -=_s i LIVING ROOM BEDROOM I0 0 0 0 0 REMOTE ANNUNCIATOR FIRE-LITE ANN-80 I I O CLOSET -I ❑ ❑ 13 10 O 0 RA II MINN ❑ , -� 0 23 S SMOKE DETECTOR FIRE-LITE SD-355 0 II 0 allLIO BEDROOM M I D '747? 0 0 0 0 0 (*So') SMOKE DETECTOR ABVOVE CLG. FIRE-LITE SD-355 BAS ENT 0 $ N" CL �S` L.J s -� 0 0 0 0 0 120 V SMOKE DETECTOR II BASEMENT C �$ FOYE O STORAGE 0 ( --) i ---) KITCHEN ,A DH B DROOM / 12 9 3 6 30 OH HEAT DETECTOR FIRE-LITE H-355 SERIES LAUNDRY F"U 0 0 0 0 0 WP H WEATHERPROOF HEAT DETECTOR FIRE-LITE 302 SERIES HALLWAY H ______I BATH ROOM ❑ II O a 7 EXISTING ROOF - ' = I — - ®e ❑ r := 1 6 0 0 7 PS MANUAL PULL STATION FIRE-LITE BG-12LX BATHROOMS _- :Y' �___.__ 2 7 2 0 11 FIRE ALARM HORN/STROBE WHEELOCK HS SERIES BASEMENT - - HALL 0 r O KITCHEN p CLco ; PORCH 0 0 0 0 0 W- WEATHERPROOF FA HORN/STROBE WHEELOCK AS SERIES O z -1 BEDROOM I O O - D❑INING ROOM DF s 0 4 2 0 6 ® STROBE WHEELOCK ST SERIES BEDROOMl 0 BASEMENT - - mm -- 0 1 0 0 1 O SPRINKLER FLOW SWITCH POTTER SERIES EXISTING CHIMNEYO e El H ( I LIVING ROOM _ O LI ® a L ALL L r �� 0 1 0 0 1 TO SPRINKLER TAMPER SWITCH POTTER SERIES e O CRAWL SPACE ❑ S ❑ I a 0 0 0 0 0 AES AUTOMATIC EXTINGUISHING SYSTEM O I I ( O �� KIT❑CHE BATHROOM CLOSET ® PS - wn WH �1 - p_..._=_ - I I R FOYER() OH MI MI ir'1"1i11111 ❑ 0 0 0 0 0 MD MONITOR MODULE FIRE-LITE MMF-301 / Li- \ -. — _ - ) CL EXISTING_...____ ___ S R ___ _._ ... _- Ps 0 5 4 0 9 DH MAGNETIC DOOR HOLDER PS . 0I - �r T _7_ �� —� Ps 0 0 0 0 0 FS FAN SHUTDOWN RELAY SPACE AGE PAM-1 I I OE CRAWL SPACE -- - 0 0 2 2 BATT BATTERIES 12 VOLT 7 .0 AH LIVING ROOM STAFF �. - ._ .. 0 0 KNOX BOX uI __.____....... O k......--„.......--.--,.. ( I PROCEDURES: I 1. STROBES SHALL REMAIN ACTIVE AFTER SILENCE FUNCTION IS PERFORMED. n 1 1— FIRE PLACE - Ps 2. HORNS TO SOUND TEMPORAL-3 SIGNAL RHYTHM. -f==--- ---r-,-.7---- ,.., .. 3. REMOTE ANNUNCIATOR WILL BE INCAPABLE OF CONTROLLING THE FIRE ALARM III I- AND WILL BE FOR ZONE/DEVICE IDENTIFICATION ONLY. LIJ 4. PULL STATIONS RESETTABLE W/FIRE-LITE KEY # 17003 DECK ABOVE 5. WP = WEATHERPROOF O PORCH O H __ _ —-T _ — _ I -._ _____. _ Ai dOrAWN (O, BASEMENT FIRE ALARM PLAN 4`' 01' FIRST FLOOR FIRE ALARM PLAN SCALE: 1/8" = 1'-0" de- SHED ROOF SHED ROOF FRE ALAN SYSTEM — SEQUE\ CE OF OPERATION 1 . OPERATION OF A MANUAL STATION WILL: __ _ ._ —_.— _- A: ACTIVATE THE HORN AND STROBES ON ALL FLOORS. ROOF ROOF - B: DISPLAY "ALARM" AT THE FIRE ALARM PANEL. C: CALL FIRE DEPARTMENT VIA CENTRAL STATION. - D: SHUT DOWN ALL FANS. DINING/KITCHEN ROOF 2. OPERATION OF AN ALARM SMOKE DETECTOR OR HEAT DETECTOR WILL: LIVING ROOM Q I' O ROOF O A: EFFECT THE SAME ACTION AS A MANUAL PULL STATION. ROOF ROOF / - D D E o E o �" BEDROOM BEDROOM ®2 ®� S II BEDROOM II - ® O CL HALL ❑s ❑ OS ROOF O ROOF / MICI11\ , H EllR H HALLO i ❑ LIVING ROOM = _. 1i ( CLD H H ❑ O HALL O DINING ROOM S 1 - CLOSET ❑ � 6 O g jC KITCHEN a_0 [i, c _ r :.,.,.:..r - == -_ j 9 'i \EXISTING -- --f_ =4- ___,_.;::<.� ._.== }-_..- I CL _ STAIRS BEDROOM I O CI r STORAGE I I ROOF ROOF 47 Ai5--c'e ( e - _ tc ,, i SECOND FLOOR FIRE ALARM PLAN 0 t-- ATTIC FIRE ALARM PLAN vmov SCALE: 1/8" = 1'-0" -VAtz I c, SCALE: 1/8" = 1'-0" 2/L' ' AREA OF ne-1)g02311\ vaksf)1,0 6 PPr WORK A 3/b, •kAPIIIE Afal CD r 1 1 ---14„-- i v,. L.,c, (Nb\ (44-11. ---ilitl„,_ , 23 7 300 r\DVIA-P_. -. --- A ::-Yr) /1\1 t°-) t)ti-u 9 A © PS © DATA CKT. / DH g -/U .(\.) 2j)C -Wig' 444/A/ Z3,1 FIRE-LITE 6 11 / vIEW 9200-UDLS �- �K FI RD o FF,E RE SUPPRESSION & N -� 9625 MAIN BAYVIEW ROAD SECURITY SYSTEMS BATT — --; �-=�.:::6d1:C , .'4N. �2o vac -7--=-- :0 A DIVISION OF EMDI LTD. �� ��� AUTO DIALER FOR CENTRAL ��� � � a SOUTHOLD NY, 11971 826 SUFFOLK AVE. BRENTWOOD N.Y. �� O �� SITE PLAN BATT STATION MONITORING VIA (2) �. ,w .� E QTWO DEDICATED PHONE LINES �� ^ `�, NTS �� j'" �eL� PH#(631 )273-2010 FAX(631 )273-2939 ((( -- FIRE ALARM PLAN LICENSE NCFM 644 SCALE s �yRISER DIAGRAM �– _--- f.' � A; z:,:; # 0� F NYS 12000259411 AS NOTED Q ; io, NO. REVISIONS DATE BY CONTACT PERSON FILE � � . rHr emit TRACEY KAMM SOUTHOLD FA.dwg fC.. DRAWN JOB # DWG. FRANK RESTITUTO, ARCH. BY RF # fr 18 CRABAPPLE LANE COMMACK, N.Y. 11725 DATE 7/30/15 FA - 1