Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
39482-Z
OfFU4�pG� Town of Southold 11/16/2015 o - P.O.Box 1179 C* r" 53095 Main Rd Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 37901 Date: 11/16/2015 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 200 Denkel Ln, Cutchogue SCTM#: 473889 Sec/Block/Lot: 97 -1-236 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 12/29/2014 pursuant to which Building Permit No. 39482 dated 1/9/2015 was issued, and conforms to all of the requirements of the applicable provisions of the law The occupancy for which this certificate is issued is ROOF MOUNTED SOLAR PANELS TO AN EXISTING ONE FAMILY DWELLING AS APPLIED FOR The certificate is issued to Kuhlmann,James&Kuhlmann, Christine of the aforesaid building SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 39482 03-11-2015 PLUMBERS CERTIFICATION DATED Authorized Signature 6�SUF QF ��c® TOWN OF SOUTHOLD BUILDING DEPARTMENT y TOWN CLERK'S OFFICE o • SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit# 39482 Date 1/9/2015 Permission is hereby granted to Kuhlmann, James & Kuhlmann, Christine PO BOX 604 Greenport, NY 11944 To install a roof mounted electric solar panel system as applied for At premises located at 200 Denkel Ln, Cutchogue SCTM # 473889 Sec/Block/Lot# 97.-1-23.6 Pursuant to application dated 12/29/2014 and approved by the Building Inspector To expire on 7/10/2016. Fees SOLAR PANELS $5000 ELECTRIC $10000 CO -ALTERATION TO DWELLING $5000 Total $20000 Building Inspector Form No 6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following A. For new building or new use- 1 Final survey of property with accurate location of all buildings, property lines,streets, and unusual natural or topographic features 2 Final Approval from Health Dept of water supply and sewerage-disposal(S-9 form) 3 Approval of electrical installation from Board of Fire Underwriters 4 Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1%lead 5 Commercial building, industrial building,multiple residences and similar buildings and installations,a certificate of Code Compliance from architect or engineer responsible for the building 6 Submit Planning Board Approval of completed site plan requirements B. For existing buildings (prior to April 9, 1957) non-conforming uses,or buildings and"pre-existing"land uses: 1 Accurate survey of property showing all property lines, streets, building and unusual natural or topographic features 2 A properly completed application and consent to inspect signed by the applicant If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant C. Fees 1 Certificate of Occupancy-New dwelling$50 00,Additions to dwelling$50 00,Alterations to dwelling$50 00, Swimming pool$50 00,Accessory building$50 00,Additions to accessory building$50 00,Businesses$50 00 2 Certificate of Occupancy on Pre-existing Building- $10000 3 Copy of Certificate of Occupancy-$25 4 Updated Certificate of Occupancy- $50 00 5 Temporary Certificate of Occupancy-Residential$15 00,Commercial$15 00 Date 1(211Q 4 New Construction Old or Pre-existing Building ✓ (check one) Location of Property V �� lary, 1 6�kkoye N L) l I q�5 House No Street VHamlet Owner or Owners of Property UfI�tJT�17� h( I M1917 Suffolk County Tax Map No 1000, Section q1 Block I Lot o�✓•(Q Subdivision Filed Map Lot Permit No Date of Permit Applicant Health Dept Approval Underwriters Approval Planning Board Approval Request for Temporary Certificate Final Certificate (check one) Fee Submitted $ ;z Applicant Signature SO(/ryolo Town Hall Annex Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 PO Box 1179 G roger rlchertO-town southold ny us Southold,NY 11971-0959 ® i� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION Issued To Christine Kuhlmann Address 200 Denkel Lane City Cutchogue St New York Zip 11935 Budding Permit# 39482 Section 97 Block 1 Lot 236 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor DBA Eastern Energy System InC License No 52689-ME SITE DETAILS Office Use Only Residential X Indoor Basement Service Only Commerical Outdoor X 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceding Fixtures HID Fixtures Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Fluorescent Fixture Pumps Transformer Appliances Dryer Recpt Emergency Fixtures Time Clocks Disconnect Switches Twist Lock Exit Fixtures TVSS Other Equipment 11 76 KW Roof Mounted Photovoltaic System to Include, 42- LG 280 Watt Panels 1-SB 6000,and 1-SB 5000 Notes Inverters,A/C Disconnect 1-Combiner Box Inspector Signature Date March 11, 2015 Electrical Compliance Form As L uIGI CLAUDIO SCIANDRA, R 5 Wesleyan Court Smithtown, NY 11787-3011 (631)543-2953 fax(631)543-1526 Cell 631-747-7495 E-mail Iestid q,.of eom Thursday, November 05, 2015 Town of Southold Building Department Town Hall Annex Building 54375 Route 25 P 0 Box 1179 Southold, New York 11971 Re Certification Letter-Fo!bl Two(42) 280 W P V Roof IM Solar Panel Ai ray, 1176 M Total Output,for Kuhlmann Residence®200 Den-Kel Lane Cutchogue, New York 11935 1 have reviewed the solar energy system installation in the subject topic on 07/2212015 The units have been installed in accordance with the manufacturer's installation instructions and the construction drawings approved by the Building Department of the Town of Southold The solar panel installation is In compliance with the requirements of the 2010 Residential Code of New York State, ASCE-05 and N F P A Standard 70 "The National Electrical Code" Markings in accordance with Section 690 53 of the National Electrical Code ai e provided To my best belief and knowledge, the work in this document is accurate, conforms to the governing codes and standards applicable at the time of submission, and conforms id reasonable standards of practice with the view to the safeguarding of life, health, property and public welfare Sincerely, aF NEW ©R co ,G\C 5C/ANQ fr P � F� 060935,' �0 � �"� �R�fiESSIQN�4 Luigi Claudio Sciandra Professional En iq neer FMLD MP�=4N=DoRx AAT& COi�'l ,NTS FQUNDA 'ION( T)IS y � ml FOUNDATION(2ND) � o rA *-3 Ol ROUGH FSG& H PLUM3VG H INSULATION PEA N.Y. STATE ENERGY 007E FINAL c 77' 0 m 0 e TOWN OF sOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applymg9 TOWN HALL Board of Health SOUTHOLD,NY 11971 4 sets of Building Plans TEL: (631)765-1802 Planning Board approval FAX: (631) 765-9502 " Survey SoutholdTown.NorthFork.net PERMIT NO. 3?47 Z Check Septic Form NYSDEC Trustees C O Application Flood Permit Examined ,20 Single&Separate Storm-Water Assessment Form Contact C411,b gCk0f Approved 1,20 / ma"o 0UN,�A�L TIC Disapproved a/c clet o 15 Pff �1P1 �-/+`�fi Phone 3(-77 - K/o(D Ey para Tori— " e Buil4g Inspector ��. DEC 2 9 2014 _ PLICATION FOR BUDDING PERMIT — BLDG DEPT Date Inlag , 20 1� TOVuPd Of SQL'THOLD INSTRUCTIONS a This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans,accurate plot plan to scale Fee according to schedule b Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas, and waterways c The work covered by this application may not be commenced before issuance of Building Permit d Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant Such a permit shall be kept on the premises available for inspection throughout the work e No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy f Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize, in writing,the extension of the permit for an addition six months Thereafter,a new permit shall be required APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York, and other applicable Laws,Ordinances or Regulations,for the construction of buildings,additions, or alterations or for removal or demolition as herein described The applicant agrees to comply with all applicable laws,ordinances,building code,housing code, and regulations,and to admit authorized inspectors on premises and in building for necessary inspectionsZ EastamEnorgyPptemaIna Wo Wund Ada r ^a Y r ��/�Matutuok,NV 1100 $ ��°ai� �ysy 0F" (@g1)"7 Ag9A (Signature of applicant or name,if a corporation) � a��� p-k 76 5owd Ave 161 U a =% I (Mailing address of applicant) C', ®U� A i � State whether applicant is owner, less , agent; ar hrtect, engineer, general contractor, electrician,plumber or`builder DATE B P # Nlftr? FEE �S BYName of owner of premises h(e7NOTIFY BUILDING DEPARTMENT Al (As on the tax roll or latest de�1� SANIu r ` If applicant is a corporation, signature of dui authorized officer FO�LOWING INSPECTIONS Ply p g Y _ I Fns��;noT Inti _T1q��j oG_��UI,RGn ELEC tl ICAL- --ATE (Name and title of corporate officer) 6NSPECT 4 REGU ED2 r, ���,, r=Rr%j,,,N �LjlAo, jG Builders License No 1'�� gg p STRAPPING, ELECTRICAL&CAULKiN6 Plumbers License No 3 INSULATION Electricians License No4 FINAL-CONSTRUCTION &ELECTRICAL Other Trade's License No - . y MUST BE COMPLETE FOR C 0 ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW 1 Location of land on wh ch proposed woA NY111 be done YORK STATE NOT RESPONSIBLE FOR gd� De N 119,�✓� DESIGN OR CONSTRUCTION ERRORS House Number Street Hamlet County Tax Map No 1000 Section q1 Block Lot Subdivision Filed Map No Lot r 2 State existing use and occupancy of premises and intended use and occupancy of proposed construction a Existing use and occupancy b Intended use and occupancy 3 Nature of work(check which applicable) New Buildin Addition Alteration Repair Removal Demolition Other Work Y ✓ (AekV71 /1 ,J /�, (Description) 4 Estimated Cost g��ko)0 6 Fee (To be paid on filing this application) 5 If dwelling, number of dwelling units Number of dwelling units on each floor If garage, number of cars 6 If business, commercial or mixed occupancy, specify nature and extent of each type of use 7 Dimensions of existing structures, if any Front Rear Depth Height Number of Stories Dimensions of same structure with alterations or additions Front Rear Depth Height Number of Stories 8 Dimensions of entire new construction Front Rear Depth Height Number of Stories 9 Size of lot Front Rear Depth 10 Date of Purchase Name of Former Owner 11 Zone or use district in which premises are situated 12 Does proposed construction violate any zoning law, ordinance or regulation9 YES NO 13 Will lot be re-graded9 YES �+r,NO Will excess fill be removed from premises9 YES NO 14 Names of Owner of premises IVj491 64441) Address aD0 Den lsel�nf? 'Phone No Q4 '16A-60976 Name of Architect �i % Qklmk&Ni ) SkiUfo, Address'5 WV-t4 w+ iD, Phone No�3\--310 Name of Contractor .Qy�'ein (1mniq l Pl T GAddress ° Phone No (�rl9'�i�f'xtGo 15 a Is this property within 100 feet of a tidal wetland or a freshwater wetland9 *YES NO * IF YES, SOUTHOLD TOWN TRUSTEES &D E C PERMITS MAY BE REQUIRED b Is this property within 300 feet of a tidal wetland? * YES NO * IF YES, D E C PERMITS MAY BE REQUIRED 16 Provide survey,to scale,with accurate foundation plan and distances to property lines 17 If elevation at any point on property is at 10 feet or below, must provide topographical data on survey 18 Are there any covenants and restrictions with respect to this property? * YES NO * IF YES, PROVIDE A COPY STATE OF NEW YORK) SS COUNTY O ,✓ 4m _ae being duly swom,deposes and says that(s)he is the applicant (Name of individual signing contra(A)ab ve named, (S)He is the (Contracto ,Agent, orporate Officer, etc) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application, that all statements contained in this application are true to the best of his knowledge and belief,and that the work will be performed in the manner set forth in the application filed therewith Sworn t�before me this I I� day of 204 Notary Public Signature of Applicant BARBARA H TANDY Notary Public,State Of New York No. 01 TA6086001 Oualified In Suffolk County Commission Expires 01/13/20 i f OF SO�ryD <o � Town Hall Annex Telephone(631)765-1802 54375 Mala Road p�aaxx 9 p P O Box 1179CAR roger.nchertt IQWnsou 1;016 nv us Southold,NY 11971-0959Q i BUILDING DEPAMUNT TOWN OF SOUTHOILD APPLICATION FOR ELECTRICAL INSPECTION ' REQUESTED BY: b"6L 6(Aj4 5 Date: 10 'al�d VHF Company Name: ko�ea Name- License No.- Address: f ! D JO q��- Phone No.: 1111 406 LF X 10 l JOBSITE INFORMATION, (*Indicates required information) *Name. {) 16w n *Address, 0 NO *Cross Street: *Phone No.: 616 A. '15 � Permit No Tax Map District 1000 Section- Block ► Lot: *BRIEF DESCRIPTION OF WORK(Please Print Clearly) to .76 9 W PV4*!� q;;; L(; 5*4A 5 6CMIZ v_I�p (Please Circle All That Apply) *Is job ready for Inspection: YES! O Rough In Final i *Do you need a Temp Certificate: ESS O Temp Information If need d) j *Service Size: 1 Phase 3Phase 100 150 200 300 350 400 Other *New Service. connect Underground Number of Meters Change of Service Overhead Additional Information, PAYMENT DUE WITH APPLICATION (10 82-Request for Inspection Form �0 !u A tbD r LZ?14 ZZ Scott A. Russell ruFF�`� ST O IRLIMMAXIER, t �°; � '� SUPERVISOR W MANAGEMENT SOUTHOLD TOWN HALL-P O_Box 1179 53095 Main Road-SOUTHOLD,NEW YORK 11971 f/ F� a` Town of,S'o u th o l d CHAPTER 236 - STORIAWWATER MANAGEMENT WORK SHEET (TO BE COMPLETED BY THE APPLICANT ) DOES THIS PROJECT INVOLVE ANY OF THE FOLLOWING.. i Yes No (CHECK ALL THAT APPLY) ❑ A. Clearing, grubbing, grading or stripping of land which affects more ! than 5,000 square feet of ground surface. 1 ❑[ B. Excavation or filling involving more than 200 cubic yards of material } within any parcel or any contiguous area. Q-C— .e-pr gamtion oiLsJ-op-0 lic,�L exceed 10 feet vertical rise to 100 feet of horizontal distance. ❑W D. Site preparation within 100 feet of wetlands, beach, bluff or coastal ; erosion hazard area. i ❑[Ij E. Site preparation within the one-hundred-year f loodplain as depicted on FIRM Map of any watercourse ❑Of F_ Installation of new or resurfaced impervious surfaces of 1,000 square feet or more, unless prior approval of a Stormwater Management Control Plan was received by the Town and the proposal includes in-kind replacement of impervious-surfaces- If urfacesIf you answered NO to all of the questions above,STOP! Complete the Applicant section below with your Name, Signature, Contact Information, Date & County Tax Map Number! Chapter 236 does not apply to your protect. If you answered YES to one or more of the above,please submit Two copies of a Stormwater Management Control Plan and a completed Check list Form to the Building Department with your Building Permit Application APPLICANT (Prooerty Owner,Design Professional Agent,Contractor,Other) S C T M DQQf3alr iQ NAME t Section Filock Lot FOR L'UILDIN`a DLP�R]'NIEINT U,7-.E ONLY COniav Information: 1-77q-4M± Reviewed By Date _ Propel ty Address / Location of Construction Work - — - _ - - - — -- — — -- = --y— --- �_ ❑ Approved fe ptB , iPermit it at Cc itiol?lar,� ot RrGuiredStorn-uater wl Storr,,watcr ivlare,em n' (c,i tiot 'lin a fteoui,ea `ro,w,rH to;_n;,n-er n;Der,ar, -,I -o RevtetN) CONSENT TO INSPECTION the undersigned, do(es)hereby state Owner(s)Name(s) That the undersigned(is) (are) the owner(s) of the premises in the Town of Southold, located at UDl Lae, N4 1/15 , which is shown and designated on the Suffolk County fax Map as District 1000, Section q j , Block I , Lot VU9 That the undersigned(has) (have) filed, or cause to be filed, an application in the Southold Town Building Inspector's Office for the following A ►'e5Ad1, rpoF 9)aK P✓f2.&er> > (vf'�r -fa 1-6AF6 uAV G5c,W Vgottsl Avee*erS That the undersigned do(es)hereby give consent to the Building Inspectors of the Town of Southold to enter upon the above described property, including any and all buildings located thereon, to conduct such inspections as they may deem necessary with respect to the aforesaid application, including inspections to determine that said premises comply with all of the laws, ordinances, rules and regulations of the Town of Southold The undersigned, in consenting to such inspections, do(es) so with the knowledge and understanding that any information obtained in the conduct of such inspections may be used in subsequent prosecutions for violations of the laws, ordinances,rules or regulations of the Town of Southold Dated /bW 11 4 tu (Print Name) (Signature) (Print Name) ho�*pE SO�Tyolo Town Hall Annex Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 PO Box 1179 Southold,NY 11971-0959 COU BUILDING DEPARTMENT TOWN OF SOUTHOLD October 19, 2015 James & Christine Kuhlman P O Box 604 Greenport, New York 11944 RE 200 Denkel Lane, Cutchogue NOTE Before the Certificate of Occupancy can be issued an Architect or Engineer must certify the installation of the solar panels was done per New York State Code TO WHOM IT MAY CONCERN Application for Certificate of Occupancy (Enclosed) Electrical Underwriters Certificate A fee of$50.00. Final Survey with Health Department Approval Plumbers Solder Certificate (All permits involving plumbing after 4/1/84) Trustees Certificate of Compliance (Town Trustees#765-1892) Final Planning Board Approval (Planning#765-1938) Final Fire Inspection from Fire Marshall Final Landmark Preservation approval Final inspection by Building Dept Final Storm Water Runoff Approval from Town Engineer BUILDING PERMIT 39482-Z Solar Panels TOWN OF SOUTHOLD PROPERTY RECORD CARD OWNER STREETVILLAGE DIST SUB LOT AmnCLI M U raw M �'�r r�,r✓ �t r L.> FORMER OWNER N E a ' ars a'1 40 rs �' , s 1>,�'�u^r r IV10h- r'1 r) V\/Gti o Zeny ' S WY TYPE OF BUILDING RES SEAS VL FARM COMM CB MICS Mkt Value LAND IMP TOTAL DATE REMARKS .5xzkf--i - r, I- r)<O-Y c,v f m .; eazl el wr n _ Q 1-,,, ��,�t/'7,m 3=� C"7 Gi n,n !7 P l�f%'9/�f'i ea 8 iT- 5!�(i - -15 ul t =_'K-) 1f 1Ay ea,-( -!le tvL�! -r r t e�f yy��/1 c� t'�r�1-264 -W l " , �p-v D �U ✓ /fid ,� �' o�� Pt9- �1�'"" 17 � - I f'h,�•I ra we(I�r-,a to ci -rrc,� 'r�vnna n L l fC-0 579 �' 1�5�g9-L101911 pc?02- IV ���a,n 4o -, he - r��i;,�f I A2P,: - e s s`f, �< e (n1 $ -C,he-r l -!Q u r '*or5- - /,5 7�"7)a- &00 ;�,�oo ,Z oc ) s r�/o 31 r Z3i(0 - 3 as 0n i;// 7 M= vp�agqw,- COs 7-h, ;-0L,-,,,A Poo)Z Tillable _ FRONTAGE ON WATER Woodland FRONTAGE ON ROAD Meadowland DEPTH House Plot BULKHEAD Total 4: t( ,�y(� r UH t f�/� .. � 1 ✓;2 -11.1 -._ <H } zj7 r. y�s, ',1s' +, 3 ■■�■■\ ■■■■■MEN■ONE IN ■■■■ 1 IN ■■■■■■■■■■ ■■■■■■■■■ ■■■■■■ ` i�syr E _ ■■■■■■■■■■■ ■■■■■■■■■■■■OMEN mom Mom mom J wh`i�t ;sj t•i RK'J Yrs f,r>�-� -1-� -- 1 }�'�C _ ,.t � ��-�� � y�trs.wZT zlb J,�v.�eST'�rYT. of f ttrdCS� r >C .ter [ �f34 r7..� 1 + '1'1 C�'l�:m 'n ■■NONE■■■■■■■■■■■■■■ ■■■■■■■ �, ..i r '1"' s r,,, -,rte,.` io T .� C *c„�,s.._ eA�•t"".�'m J r ref,enc 4 ,r i t t r MEN■■■■■■■■■■■■■■■■■■■■ No NNE ■■■■■■■■■■■■■■■■■■■■■■■■■■■■■ ■■■■■NNE ■ ■■■ ■■NEON ■■ ■ mom ■_■■■M■ ONO■■■■■■ IN 0 EMEM mom ■■t MMUNIM■ SENSE ■■■■ ■■■�■■o®m■■■■■■■■'®■(mm■■■■■■■■■ •. ■■■©l■■®■■■■■■■ !■■111M■■■■■■■■■■ ■■■■;■■■■■■■ ■■� a■II■■■ ■■■■■■■ ZMEEM MEN ■MIN■■■■■EM■■■®■©ra■■■■■ ■■■■■■■ �moo■■■■u■■o■■M■■■■■■t■■■■■■■ w s I 14/ 0/ F COX LANE ASSOCIATES VACANT ) Y N. 43 " 05 20 It W. 168 94 ' . � X N RI G H T OF W AY o r I SO' WIDE 43 ZS ZD"E m ' N t I O ,Fu " Zb t t C' = t t o i iri in 1 Z ^� lip tr -n E -- \ t — m O' �`i o 1 O r � I o z rai t� O a w 1 N 24.21 m 411L4'IN p I .k (" 2 STY. FR v N - O a 2,.2' a HSE W/DAR. N N Q N A 41L 4 O i r c— m CD -- m 0 S 4,3033 ' 00"E . 168. 66' N / OlF HOWARO ROBINSON (!VACANT I � E i r+ t , Jop RLp,N00 �► 0 � The dowflons of weds a d oer�ipodr dwwn hwom ore from AWd r: Q j obnrraHo+rr and or horn dale oblairwd lFoat vGhets. W Z * SUFFOLK COUNTY DEPARTMENT OF HEALTH SERVICES 'Q FOR APPROVAL OF CONSTRUCTION C*LY W DATE HS F.F. N0-- 25, O25, ° N X o° 0 a N APPROVED h f U b! s y7o 3r•w• THE WA To Suon�' ANA SEWAGE "OSAL s 113040408WFACX,ITES FOR ALL LOTS N•TMS DEVELOFfA•NT s as• S RT E.25 } OFF TTW�FaaK COUNTY�aR�T OF W- LM ROAD � N.Y. M AIN- ' . Pr*wod h mwdvm *0 M6 �n qja� for ON arveys a il;t&"w _ Tri =nw °. AREA = 1. 0152 ACRES LOT N.IMeERS REF TO •r�toR SUSDlVWON ' SURVO.Y OF PROPERTY MADE FOR WLLlAM L It MUREL A. MURRAY . CERTIFIED T0, COMMONWEALTH LAND TITLE AT INSURANCE COMPANY CUTCHOGUE SOUTHOLD $A VINGS BANK MOHRING ENTERPRISES, INC. TOWN OF SOUTHOLD �� ,AND SU9 ME? SUFFOLK COUNTY , N.Y. 097 - 01 - P/O 25.2 Wo ,S. LIC. NO. 4961'8 kALE I"s MY S, P.C. I AUG. 16, 1988 F t5 8 SEPT. 29,1988 t FOUNDATION I MAW R OCT. 21 , 19 88(FINAL) SOUT _out N.Y. 11971 1 10-448 revise (Cert.) _ .a-.PAf-AR sne moi 'h. I � 4 LUIGI CLAUDIO SCIANDRA, P.E. 5 Wesleyan Court Smithtown, NY 11787-3011 (631)543-2953 fax(631)543-1526 E-mail Ics4d@aol com Tuesday, December 16, 2014 Eastern Energy Systems 7470 Sound Avenue Mattituck, New York 11952 Tel. 631-779-4004 Attn.: Mr. Mike Lawton Engineer/Project Manager Re Forty Two (42) 280 W P. V. Roof Top Solar Panel Array, 11.76 kW Total Output, for Kuhlmann Residence—200 Den-Kel Lane Cutcho-Que, New York 11935 Dear Mr Lawton Pursuant to your request, I have reviewed the following Information regarding the subject roof top solar panel array • Cover Sheet with Site Visit/Venfication prepared by E2Sys representative Identifying specific site information including size and spacing of rafters for the existing roof • Design drawings of the proposed system to include site plan, roof plan, mounting details for the solar panels This information was prepared by E2Sys and will be utilized for approval by the Town of Southold and for construction of the,proposed system Based on the above documentation, I have evaluated the structural capacity of the existing system to supoorE the additional loads imposed by the solar panel arrays and offer the following comments The existing roof type is provided with composite shingles, one(1)layer, age less than 5 years, 2"x8" Douglas Fir rafters at 16" on center, 1/2" thick plywood roof decking with 230 roof pitch, 2"x6" ceiling joists at 16" on center Our review of the photos of the exterior roof indicates no signs of settlement or misalignment caused by overstressed underlying structural members Structural Analysis The structural analysis has been carried out using the following design criteria resign wind speed (3 sec gust) 120 mph Ground snow load 20 lbs/sq ft Solar Array 1 Dead Load 2 6 lbs/sq ft Solar Array 2 Dead Load 2 5 lbs/sq ft 1 Total Weight of Array 1 1607 4 lbs Total Weight of Array 2 369 2 lbs The above values are within acceptable limits of recognized industry standards for similar structures The structural analysis, performed for the existing structure and for the solar panel arrays, utilizing the above design loads, indicates that the existing roof rafters will be able to supports the additional panel weight without damage, if installed correctly The onsite inspection and the photographs show that the roof framing is in good conditions However, the dwelling owners are to be made aware that long term build up of heavy snow conditions may produce deflections in the roof structure If any deflection is noticed, than it is recommended that the solar panels be cleared of accumulated snow more than one (1) foot deep over a period of one week If no deflections are visible under any snow loading over a period of time, then there is no need to clear the solar panels Based on the above evaluation, it is the opinion of the undersigned professional engineer, that with appropriate solar panel anchors being utilized, the roof system will adequately support the additional loading imposed by the solar panel arrays This evaluation is in conformance with the 2010 Residential Code of New York State, the 2001 Wood Frame construction Manual, SEI/ASCE 7 "Minimum Design Loads for Buildings and Other Structures", current industry standards and practice and based on documentation and data supplied by E2Sys at the time of this report Should you have any questions regarding the above or if you require additional information, do not hesitate to contact me Sincerely, uigi Claudio S iandra, P E OF NEW f 0 O SCIgNo��'f P X ,1 60935 a AROFESSIOO 2 SCOPE OF WORK `a DESIGN&DRAFTING BY r JAMIE MINNICK TO INCERTIFIED A'14 3 KW SOLAR PHOTOVOLTAIC (PV) SYSTEM AT THE �'' � \ NABCEP CERTIFIED KUHLMANN RESIDENCE, LOCATED AT 200 DEN-KEL LANE 051112-129 THE POWER GENERATED BY THE PV SYSTEM WILL BE INTERCONNECTED �h WITH THE UTILITY GRID THROUGH THE EXISTING ELECTRICAL SERVICE EQUIPMENT REVISIONS THE PV SYSTEM DOES NOT INCLUDE STORAGE BATTERIES DESCRIPTION DATE REv SYSTEMRATING ORIGINAL 11-012014 A 1176 kW DC STC 8 61 kW DC PTC OIF NEW YO EQUIPMENT SUMMARY ro SCIA 42 LG 280-SIC B3 PV MODULES J 1 SMA SB6000 TLUS-22 (240) s "°� �® CONTRACTOR I SMA SB5000 TLUS-22 (240) - IRONRIDGE XRS1000 MOUNTING SYSTEM SHEET INDEX �2s�a 060935-1 PV-1 COVER pROFESSION� PV-2 SITE MAP & PV LAYOUT PV-2 1 ROOF A LAYOUT SOLAR UNIVERSE PV-3 MOUNTING DETAIL & STRUCTURAL LOAD CALCULATIONS 6 �„ �,o, SOL SOUND AVE GOVERNING CODES *" °� -� e MATTNSE#43889H w � ® d.0 LICENSE#43889 H 2011 NATIONAL ELECTRICAL CODE /9 a� PROJECT NAME 2010 RESIDENTIAL BUILDING CODE OF NEW YORK STATE UNDERWRITERS LABORATORIES (UL) STANDARDS �/ '�• -- OSHA 29 CFR 1910269 PROJECT LOCATION W l.f) GENERAL NOTES z W en 1 CONTRACTOR SHALL CHECK AND VERIFY ALL CONDITIONS` '- - > '1 , � Q z �- AT THE SITE PRIOR TO STARTING TO WORK AND SHALL •+ '.,r J z FAMILIARIZE HIMSELF WITH THE INTENT OF THESE PLANS _ �., ,. W W AND MAKE WORK AGREE THE SAME dY , , � Y W 2 CONTRACTOR OR OWNER SHALL OBTAIN ALL REQUIRED v ` " r " a APPROVALS, PERMITS, CERTIFICATES OF OCCUPANCY, ::) Z 10 CONTRACTOR TO EFFECT AND MAINTAIN INSURANCE, I E R f sr z INSPECTION APPROVALS, ETC, FOR WORK PERFORMED " FROM AGENCIES HAVING JURISDICTION THEREOF, IF CONTRACTOR'S LIABILITY, WORKMAN'S COMPENSATION, z W REQUIRED COMPLETED OPERATION, ETC ADEQUATE FOR THE 3 ALL WORK SHALL CONFORM TO CONSTRUCTION CODE PURPOSES OF THIS PROJECT AND FURNISH PROOF OF := SAME PRIOR TO COMMENCING WITH WORK AND ALL RULES AND REGULATIONS OF THE RESPONSIBLE ® (� JURISDICTION 11 EACH SUBCONTRACTOR SHALL BE RESPONSIBLE FOR _ �- 4 IF IN THE COURSE OF CONSTRUCTION A CONDITION MAINTAINING SAFETY ON THE JOB SITE DURING THE :D N CONSTRUCTION PHASE TO COMPLY WITH THE REGULATIONS EXISTS WHICH DISAGREES WITH THAT AS INDICATED ON - ,t> � AND REQUIREMENTS OF THE OCCUPATIONAL SAFETY AND �� j THESE PLANS, THE CONTRACTOR SHALL STOP WORK AND HEALTH ADMINISTRATION THIS SHALL INCLUDE, BUT ARE f I.r NOTIFY THE ENGINEER SHOULD HE FAIL TO FOLLOW THIS ; PROCEDURE AND CONTINUE WITH THE WORK, HE SHALLNOT LIMITED TO PROVIDING FOR ADEQUATE AND PROPER " ASSUME ALL RESPONSIBILITY AND LIABILITY THEREFROM BRACING, SAFETY RAILINGS AND SECURE FOOTINGS FOR '�' rt �rwn - SHEET NAME 5 ALL STRUCTURAL STEEL SHALL BE A-36 AND SHALL BE ALL TEMPORARY SCAFFOLDING, STAIRS, ETC AS WELL AS PERMANENT CONSTRUCTION FABRICATED AND INSTALLED AS PER LATEST A I S C - SPECIFICATIONS 12 FIGURED DIMENSIONS SHALL GOVERN DO NOT SCALE _ * j r; ! fir COVER DRAWINGS, WHERE DIMENSIONS ARE ESTABLISHED BY 6 ALL ELECTRICAL WORK SHALL BE BOARD OF FIRE 1 EXISTING CONDITIONS EACH CONTRACTOR SHALL VERIFY UNDERWRITERS APPROVED AND IN ACCORDANCE WITH NEC & NYS CODES & REGULATIONS EXISTING CONDITIONS PRIOR TO ORDERING MATERIALS ANDY'=.� �� , Y� COMMENCING WITH WORK ,a ,� SHEET SIZE 7 ANY DEVIATION FROM THESE PLANS WITHOUT THE WRITTEN CONSENT OF THE ENGINEER WILL NEGATE THE 13 CONTRACTOR TO REMOVE ALL DEBRIS CREATED BY THIS ` r ' ENGINEER'S CERTIFICATION OF THESE PLANS WORK FROM THE SITE AND DISPOSE OF IN A LEGAL ,� - ,r 8 THESE DRAWINGS AS INSTRUCMENTS OF SERVICE ARE MANNER ON A WEEKLY BASIS OR SOONER IF CONDITIONS _ 4 WARRANT AND SHALL REMAIN THE PROPERTY OF THE ENGINEER 14ATTHE 14 AT THE COMPLETION OF WORK, THE SITE TO BE � WHETHER THE PROJECT FOR WHICH THEY ARE MADE IS CLEARED OF ALL DEBRIS AND EXCESS MATERIALS THE EXECUTED OR NOT THEY ARE NOT TO BE USED ON ANY FACILITY IS TO BE LEFT BROOM CLEAN AND WORK IS TO BE i y SHEET NUMBER OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT COMPLETED TO THE TOTAL SATISFACTION OF THE OWNER AERIAL VIEW 9 CONTRACTOR SHALL PROTECT, PATCH AND REPAIR ALL PRIOR TO RELEASE OF FINAL PAYMENT PV- EXISTING WORK ADJACENT TO HIS WORK, OR DAMAGED AS RESULT OF HIS WORK DESIGN DRAFTING BY JAMIE MINNICK \ NABCEP CERTIFIED 0 5111 2-12 9 w REVISIONS 1 w DESCRIPTION DATE REV f I I ORIGINAL 11 01-2014 A G I I I I � I � I ,—IE)GROUNDING ELECTRODE a UTILITY METER& ` ' I w MAIN SERVICE PANEL C / DISCONNECT 1 1 OMBINER 18 FIRE SETBACK ®RIDGE. 1 - INVERTER ��/ ' SMA 385000 / I _ I _I I I I I I I i I I I VERTER I I O- TO 118 (FIRE SETBACK @ RIDGES SMA 386000 I ° T H 7 1 1 , CONTRACTOR 3 PITCH `-1 I 1 I 'O O I I 123 PITCH ' CHIMNEY SOLAR MODULE I O I O O O 't` ATTACHMENT POINT RACKING RAIL ® RAFTERS 16 OC TYP , I I 1 1 _ SOLAR UNIVERSE x 7470 SOUND AVE COMPOSITE SHINGLE. „ , _ _� y ' _ .. ,t ^'S 1 t '` ' - NEW ROOF UNDER ARRAYS 1 LAYER AGS YRS MATTITUCK,NY 11952 z, a LICENSE#43889 H E PROJECT NAME Ln OF NEW .' ' „ (� W M SCIq YpR�► - e y - ;' ,1: z z d1 LLI Uj SAO 060935-" Q 0 AROFESSIONP�- F J 0 F ` N :D CONSTRUCTION SUMMARY (42) LG 280 S1C-B3 SOLAR MODULES TOTAL, 11 76 kW DC STC (1) SMA SB6000 TLUS-22 (240), 6 0 kW AC (NOMINAL) A5Pf1ALT `= SHEET NAME (1) SMA SB5000 TLUS-22 (240), 5 0 kW AC (NOMINAL) (86) ATTACHMENT POINTS @ 72" OC MAX DRIVEWAY PU Roof Type = Comp Shingle, Age<5 YRS, # of Layers 1 Y Roof Structure = 2x8 Douglas Fir Rafter @ 16" 0 C, %" Plywood Declang LAYOUT Roof/Array - Pitch 23 - 23, Azimuth 232 / 232 SHEET SIZE ANSI-B " " CONSTRUCTION NOTES - DEN KEL LANE 11 x17 1 ) ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE SHEET NUMBER MANUFACTURER'S INSTALLATION INSTRUCTIONS ��— 2 ) ALL OUTDOOR EQUIPMENT SHALL BE RAINTIGHT WITH MINIMUM NEMA 3R RATING 3 ) ALL LOCATIONS ARE APPROXIMATE AND REQUIRE FIELD VERIFICATION CONSTRUCTION SUMMARY - ROOF 1 & 2 DESIGN&DRAFTING BY JAMIE MINNICK (42) LIS 2:0 S1C-B3 SOLAR MODULES TOTAL, 11 76 kW DC STC NABCEP CERTIFIED 051112-129 (1) SMA SB6000 TLUS-22 (240), 6 0 kW AC (NOMINAL) (1) SMA S85000 TLUS-22 (240), 5 0 kW AC (NOMINAL) REVISIONS (86) ATTACHMENT POINTS @ 72" OC MAX DESCRIPTION DATE REV Roof Type = Comp Shingle, Age<5 YRS, # of Layers 1 cl Roof Structure = 2x8 Douglas Fir Rafter @ 16" O C, %2" Plywood Decking ORIGINAL 11 01 2014 A Roof/Array - Pitch 23 - 23, Azimuth 232 / 232 Wo II w CONTRACTOR m W F 0 CLLJ n w l U_ YrE GROUNDING ELECTRODE 0O ~ TILITY METER& AIN SERVICE PANEL SOLAR UNIVERSE 7470 SOUND AVE wC DISCONNECT MATTITUCK,NY 11952 IX LICENSE#43889 H �- OMBINER 18" FIRE SETBACK"'@ RIDGESVERTER SMA SB5000PROJECT NAME VERTER SMA SB6000 18' FIRE SETBACK" @RIDGES LIJ Ln - U 1'1 • / 3e PITCH Z iJ�l O 23° PITCHhe ne ky"e 1�1 Z r 14'-54 STR# 1 STR# 3 k u�� STR# 4 15'-3° W J Z ARRA # 1XI 13'-3° CHIMNEY 1 1 _1" z iAK V It Z z STR# 2 < ® O 4 6 he kylne 5kylhe Skylne Ine - 1 � O U 10 9 IL 8 7 , I 6 j Sky]- n ane 94° O 1 6 4 N Y U 1'42 43'-44 3'-32° 32 47'-10" 24'-4° SHEET NAME ROOF 1 �p(�G OF NEW y0 C SCIq O v�G SHEET SIZE ANSI-B 11 " x17" STRING LEGEND �2 �' STIR# = STRING# s� 060935-1 JB # = JUNCTION BOX# O ((�` SHEET NUMBER CB # =COMBINER BOX# INV# = INVERTER# ROFESSION� PV-2.1 LOAD CALCULATIONS-ARRAY 1 LOAD CALCULATIONS-ARRAY2 DESIGN&DRAFTING BY Module Wel ht 36 96 Lbs Module Wel ht 36 96 Lbs �� OF NEW yo JAMIE MINNICK # of Modules 34 # of Modules 8 .�P S R� (E) 2x8 RAFTER DOUG FIR @ 16" O C NABCEP CERTIFIED Total"Mcidule Weight 1256 6 Lbs Total Module Weight 295 7 Lbs COJAG\G os1112 tz9 Total Length of Rall 265 3 Ft Total Length of Rall 55 Ft v Rad Wel ht per Foot 09 Lbs Rall Weight per Foot 0 9 Lbs REVISIONS Total Rall Wet ht 238 8 Lbs Total Rall Wel ht 49 5 Lbs DESCRIPTION DATE REV Weight per standoff 2 Lbs Weight per standoff 2 Lbs ORIGINAL 11-01-2014 A Total Standoff Weight 112 Lbs Total Standoff Wel ht 24 Lbs p �!!/ 15'3• Total Array Wel ht 16074 Lbs Total Array Weight 369 2 Lbs = Point Load 28 7 Lbs Point Load 307 Lbs S� 60935-1 O Total Array Area 630S Ft Total Arra Area 147 S Ft A �� Arra Dead Load 6 Lbs/S Ft Arra Dead Load 5 Lbs/S Ft ROFESSIOW, As per ASCE 7 - Method 1 D fig 6-2 # (table - 1 P net =0 Kzt 1 Pnet30 eq 6-2 Kzt sec 6 5 7 1 net to e - # 23 EG CLIMACTIC AND Ground Wind Speed Live load, Point Max fastener GEOGRAPHIC DESIGN Category Snow Load 3 sec gust pnet30 per pullout load Fastener Type spacingalong CRITERIA Pg mph ASCE7, psf Ib railin (E) 2x6 CEILING JOIST coNrRAcroR @16" OC A # 20 120 # 468 5/16" x 3-1/2" Stainless Steel B # TYP TYP # TYP Lag Bolts 1'-24 9'-4 Roof Section # 72•' 2 # (E) LOAD BEARING WALL (E) LBW ROOF FRAMING DETAIL SOLAR UNIVERSE 7470 SOUND AVE TABLE RR301.2(1) SCALE 1' = 2 MArnTUCK,NY 11952 LICENSE#43889 H E+ 12 m -- 24�n 48 m CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA PROJECT NAME _ WIND_ SUBJECTTO DAMAGE FROM _ GROUND SPEED FROST W Lr) SNOW 3 SEC SEISMIC LINE ICE SHIELDV W M LOAD GUST DESIGN DEPTHb TERMITE` UNDERLAYMENT FLOOD MODULE MOUNTING CLIP W Z (PSF) (MPH) CATEGORY WEATHERING3 (FT-IN) REQUIRED9 HAZARDf SOLAR MODULE Q 20 110 C SEVERE T-0" MODERATE YES NO ' STAINLESS STEEL 3/8" TO HEAVY BOLT AND NUT 1 �.J Z For SI 1 pound per square foot=0 0479 kN/m2,1 mile per hour=1 609 km/h �• W W a Weathering may require a higher strength concrete or grade of masonry than necessary to satisfy the structuralZ Z) requirements of this code The weathering column shall be filled In with the weathering index (I e,"negligible," UNIRAC ALUMINUM RAIL ALUMINUM FLASHING "moderate"or"severe")for concrete as determined from the Weathering Probability Map[Figure R301 2(3)] The ALUMINUM"L"BRACKET Q C) O grade of masonry units shall be determined from ASTM C 34,C 55,C 62,C 73,C 90,C 129,C 216 or C 652 ALUMINUM PV QUICKMOUNr O b The frost line depth may require deeper footings than indicated in Figure R403 1(1) The jurisdiction shall fill in the = frost line depth column with the minimum depth of footing below finish grade (V :DCOMPOSITION ROOF C The jurisdiction shall fill to this part of the table to Indicate the need for protection depending on whether there has 5/16 x 6"STAINLESS Y V been history of local subterranean termite damage STEEL LAG BOLT WITH 2 1/2 MIN THREAD PENETRATION SEALED d The jurisdiction shall fill In this part of the table with the wind speed from the basic wind speed map[Figure WITH GEOCEL 4500 SHEET NAME R301 2(4)] Wind exposure category shall be determined on a site-specific basis In accordance with Section R301 2 1 4 MOUNTING e The jurisdiction shall fill to this part of the table with the Seismic Design Category determined from Section DETAIL & R301 2 2 1 LOAD CALCS f The jurisdiction shall fill In this part of the table with(a)the date of the jurisdiction's entry into the National Flood Insurance Program(date of adoption of the first code or ordinance for management of flood hazard areas),(b)the SHEET SIZE date(s)of the currently effective FIRM and FBFM,or other flood hazard map adopted by the community,as may be amended g In accordance with Sections R905 2 7 1,R905 4 3 1,R905 5 3 1, R905 6 3 1,R905 7 3 1 and R905 8 3 1,where there has been a history of local damage from the effects of ice damming,the jurisdiction shall fill In this part of the MOUNTING DETAIL 3 table with"YES"Otherwise,the jurisdiction shall fill in this art of the table with"NO" 1 p SCALE 1" = 6" ---� SHEET NUMBER _I I The ground snow loads to be used in determining the design snow loads for roofs are given to Figure R301 2(5)for 3m 6m 12m� � I ��V/_ sites at elevations up to 1000 feet Sites at elevations above 1000 feet shall have their ground snow load Increased from the mapped value by 2 psf for every 100 feet above 1000 feet