Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
40078-Z
,o�1g11FFOtefitie Town of Southold 10/29/2015 :11? t. P.O.Box 1179 53095 Main Rd •oy o�� Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 37872 Date: 10/29/2015 THIS CERTIFIES that the building GENERATOR Location of Property: 325 Indian Neck Ln,Peconic SCTM#: 473889 Sec/Block/Lot: 86.-1-4.22 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 8/27/2015 pursuant to which Building Permit No. 40078 dated 9/10/2015 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: ACCESSORY GENERATOR AS APPLIED FOR The certificate is issued to Reitman,Joel&Reitman,Anne of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 40078 10-22-2015 PLUMBERS CERTIFICATION DATED Authorized Signature li a TOWN OF SOUTHOLD ,,i X4.1) ' BUILDING DEPARTMENT a TOWN CLERK'S OFFICE 1 cm�* , SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 40078 Date: 9/10/2015 Permission is hereby granted to: Reitman, Joel & Reitman, Anne PO BOX 528 Peconic, NY 11958 To: Install generator as applied for. At premises located at: 325 Indian Neck Ln, Peconic SCTM # 473889 Sec/Block/Lot# 86.-1-4.22 Pursuant to application dated 8/27/2015 and approved by the Building Inspector. To.expire on 3/11/2017. Fees: ACCESSORY $100.00 CO -ACCESSORY BUILDING $50.00 ELECTRIC $85.00 Total: $235.00 Building rrspector Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following- A. For new building or new use: 1. Final survey of property with accurate location of all buildings, property lines, streets, and unusual natural or topographic features. 2 Final Approval from Health Dept. of water supply and sewerage-disposal (S-9 form). 3 Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead 5 Commercial building, industrial building, multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings (prior to April 9, 1957) non-conforming uses, or buildings and "pre-existing" land uses: 1. Accurate survey of property showing all property lines, streets,building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00, Alterations to dwelling$50.00, Swimming pool $50.00,Accessory building$50.00,Additions to accessory building$50.00,Businesses$50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy-$.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy-Residential$15.00, Commercial$15.00 Date. q- ® -15 New Construction: Old or Pre-existingBuilding: (check ,, p g one) Location of Property: 32' / 4( ,- 9V0e._ �ij�,m.�• P ��/� House No. Street Hamlet Owner or Owners of Property: ,10-e--( a +r Ar‘ Suffolk County Tax Map No 1000, Section .g 1p Block ( Lot L , Subdivision Filed Map. Lot: Permit No f oo J g Date of Permit. Applicant: Health Dept Approval: Underwriters Approval: Planning Board Approval- Request for. Temporary Certificate Final Certificate: f (check one) Fee Submitted: $ �7 f ` ' ApAcant Signature ,',�, ... �_- Town Hall Annex � ® : Telephone(631)765-1802 54375 Main Road % alk ; Fax(631)765-9502 P.O.Box 1179 �� Southold,NY 11971-0959 _it �O�1� roger.richert(a�town.southold.ny.us OU �, viii o'/ BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION Issued To' Reitman Address: 325 Indian Neck Lane City: Peconic St: New York Zip: 11958 Building Permit#: 40078 Section: 86 Block: 1 Lot: 4.22 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: Laurel Lighting License No: 4718-ME SITE DETAILS Office Use Only Residential X Indoor Basement Service Only Commerical Outdoor X 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures HID Fixtures Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel NC Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Fluorescent Fixture Pumps Transformer Appliances Dryer Recpt Emergency Fixtures Time Clocks Disconnect Switches Twist Lock Exit Fixtures TVSS Other Equipment' 11 kw Stand By Generator with 100A Transfer Switch Notes: 'S2Inspector Signature: Date: October 22, 2015 Electrical 81 Compliance Form.xls FIELD INISPECTTON REPORT DATE CONJ,M'FiNTS • 'Ot3 i ON(1ST) , • ' •• I • , : . ' . :. ... , . . . . OD l.. 1 r • }..,...t..... • l . ' • . Ci) tll.-‘7{ • Vv� • • ROUGH FRtNg•& -- I PLUIVIBrN'G __._� - " . • ,1 • . f.....1 INSULATION PER N.Y. - . STATE ENERGY CODE --..,r.,-.w..r ' - r' -- • • • t •..1 , • , .. •. ., W. �..:�. � ••: tom'„' `� � .. . , t• . I •s 1 I'. .1 1• t • . • .. .......r • • • • , , ' f . • . • . -. • • I 1 • • • fift/C / . • /) )5-- Aec kg- ,ig 1 Z•35' .. . ( OPP ; 121/(14734'c r pl N.1 ab . , . Z • , • • ;') . . - ' ti Lt, - , • ti • t. i "7 TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL " . Board'of Health ' SOUTHOLD, NY 11971 _ . 4 sets of Building Plans TEL: (631) 765-1802 Planning Board approval FAX: (631) 765-9502._ ,/`�� 1 z____ - Survey SoutholdTown.NorthFork.net PERMIT NO. ((�� 0 Check 1 ' !. '` . , Septic Form • N.Y.S.D.E.C. Trustees C.O.Application / Flood Permit- Examined 9 l/ ,20 I S Single&Separate i ' Storni-Water Assessment Form Contact: Approved ` ci C 0 ,20 [S . ; ° ' ti - r " Mail to: Disapproved a/c --- • - ' • Phone: �`3 t 77(:c• 2/ Expiration /I I _ ,20 (7 -- - i1r [LZ ,1 r Ir' �� l f , .' ,� ' n -' �' ��' '`-' I �.�•� ,' Building I/nspector _ _ #•`_ 11 J 1 i f` 1 1.1...) APPLICATION-FO-R BUILDING PERMIT '1—I�� AUG 2 7 -Z0�5w,•..,, ' L---- — Date , 20 1! — 3LDG DEP[ i''`INSTRUCTIONS --• ' ''.5` - - - - ' _ I '\fl,cel- 'Ohl-HOLD a. This application MUST be completely filled in by`typewr`•iter'"or'•iu ink .nd.submitted to the Building Inspector with 4 sets of plans, accurate plot plan to scale. Fee according to schedule. b, Plot plan showing location of lot and of buildings on_premiserelationship to,adjoining premises,or public streets or areas, and waterways. c.The work covered by this application may,not.l e commenced. efore,issuance of,Building Permit. d.Upon approval of this application,the Building Inspector will issue a Building'Permit to{;lie applicant. Such a permit shall be kept on the premises available for inspection throughout the}work. " e.No building shall be occupied or used in whole or in'pai-t'for'any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. , f.Every building permit shall-expire if the work authorized'has not commenced within-l2 months after the date of issuance or has not been completed within 18 months from such:date:-If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building.Inspector,`mayauthorize, in.writing,the-extension of the permit for an addition six months. Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE.to_the Building;Depai;tmentfor the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town;of•S,quthold,Suff,lk'.County,New York; and other:applicable Laws,}Ordinances,or Regulations, for the construction of buildings, additions, or alterations or,,for removal or demolition;as herein described.The applicant agrees to comply with all applicable laws, ordinances,building;code,,housing code,and regulations,'and'to admit authorized inspectors on premises and in building for necessary inspections. ' . , (Signa ; ,o plicant or name,if a corporation) • _ (Mailing.addres'of applicant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder Name of owner of premises Je- ( ��r , , . . . ., • �h; (A's"on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer , (Name and title of corporate officer) , .,`, 1 '; i Builders License No. Plumbers License No. • ' .. Electricians License No. ' " V • Other Trade's License No. ,, . . 1. Location of land on which pro posed work will be done: 3 3- - 1 Yl"if d i _ „ " p/ f1I' ( House Number Street 1,,. 'Ijamlet County Tax Map No. 1000 Section tFBl blch7,11f{3 .ti y;tt=7:1u+:• Lot 14 A d.\ Subdivision Filed Map No. Lot , • 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy b. Intended use and occupancy CJ,✓ -fio✓ 3. Nature of work (check which applicable): New Building Addition X Alteration Repair Removal' Demolition Other Work (Description) 4. Estimated Cost Fee (To be paid on filing this application) 5. If dwelling, number of dwelling units Number of dwelling units on each floor If garage, number of oars' 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of existing structures, if any: Front Rear Depth Height Number of Stories Dimensions of same structure with alterations or additions: Front Rear_ Depth Height r; .ar,,: :° ; Number of Stories 8. Dimensions of entire new constructions.Front.::- ';t ; Depth Height Number of Stories CUr. 9. Size of lot: Front Rear ;:;�a I ,�, ; : . ; Depth 10. Date of Purchase • . Name of Fortner Owner ' ,•• , ' - '•, • 11. Zone or Use district in which'premises are fsituated ' '' • '''' ,' 12. Does proposed coiistruction'v=iolate any,zoning'law;;;ordinahce`orregulation? YES NO 13. Will lot be re-graded?,YES , NO Will excess'fill4be'zemoved from•premise:s? YES NO 14. Names of Owner of premises ., ,, , ,.,. -Address ., . • 'Phone No. Name of Architect __a.., ...-.. a_. ,. .Add'ress'. i .,:itl;, . Phone No : , Name of Contractor • ' '$ -,y1,, Address= ;F: A.;s. : ,-Phone No.' • . ' 15 a. Is this propertywithin-100 feet of;a tidal wetland:Ior atdshwater wetland?!*IYES'.: NO . • * IF YES, SOUTHOLD TOWN TRUSTEES &:DIE:a'PERNIITS'MAY''BE`R EQUIRED." - - b. Is this property'within'300'feet"of a tidal wetland?*`YES"' ;NO : ' '' * IF YES; D:E.C. PERMITS'MAY-13E REQUIRED. ''• 16. Provide survey, to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point On property is"at 10 feet or below, must provide topographical data on survey. 18. Are there any cove_nants and,restrictions with respect to this property? * YES NO * IF YES, PROVIDE A COPY. STATE OF NEW YORK) SS: COUNTY OF ) - .beingrduly sworn, deposes and says that(s)he is the applicant ' (Name of individual signing contract)above named, ' (S)He is the (Contractor,Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be performed in the manner set forth in the application filed therewith. - - Sworn to before me this 2.-7 4-Pc) day of ,1 L, 4 20 Cs�Vv---/ '`-l/a"1 CONNIE D.BUNCH Notary Public Notary Public,State of New York ° S1 nature of Applicant No.01 SUSI 65050 Qualified in Suffolk-County Commission Expires April 14,2 VI to • 1 Scott A_ Russell fav '- sToRMWAT]ER �' t 'G ' MANAG)EMUEN T SUPERVISOR �, r _ SOUTHOLD TOWN HALL-P.O.Box 1179 \ I 53095 Main Road-SOUTH OLD,NEW YORK 11971 a - ' Town of So u th o l d ••O� CHAPTER 236 - STOR1V[WATER MANAGEMENT WORK SHEET ( TO BE COMPLE HID BY THE APPLICANT) DOES THIS PROJECT INVOLVE ANY OF THE FOLLOWING: CO1EIX ALL THAT APPLY) Yljes N11\1: 1 A. Clearing, grubbing, grding or stripping of land which affects 'more i than 5,000 square feet of ground surface. El B. Excavation or filling involving more than 200 cubic yards of material • within any parcel or any contiguous area. ❑VC_ Site preparation on slopes which exceed 10 feet vertical rise to 100 feet of horizontal distance. ❑IZfD_ Site preparation within 100 feet of wetlands, beach, bluff or coastal erosion hazard area. LI17(E_ Site preparation within the one-hundred-year floodplain as depicted on_FIRM Map of any watercourse, _ ❑ F. Installation of new or resurfaced impervious surfaces of 1,000--square- -'.- feet or more, unless prior approval of a Stormwater Management • Control Plan was received by the Town and the proposal includes in-kind replacement of impervious surfaces. * If you answered NO to all of the questions above, STOP! Complete the Applicant section below with your Name, Signature, Contact Information, Date & County Tax Map Number! Chapter 236 does not apply to your project. If you answered YES to one or more of the above, please submit Two copies of a Stormwater Management Control Plan and a completed Check List Form to the Building Department with your Building Permit Application_ APPLICANT- (Property Owner.Design Professional,Agent.Contractor-Other) S.C.T.M. l 000 Date ab m District -/ NAME. ( 'I`ej ✓X a„�„ 4 Section Block Lot 5...�,., FOR BUILDING DEP�ARTNi,_NT L:::1 ONLY Contact Informal ion e- T ` 61-4A dA., Reviewed By. .P - - - - - - - - - - - - - - - - - !?ate: 7 /ii Property Address / Location of Construct ion Work: bl /ot/1 d'V/ k LA X' Approved for procetng Building Permit (� ,.-t� Stormwater Management Control Plan Not Required _it_-/( /M• c; Stormwater Management Control Plan a Required !Forward to Engineering Department for Rrirks/) [ORM ' ' M-1CP TOR ,.1i1'Y ;Plo �,0��0�SO�lyo i' • Town Hall Annex Y lepheae*34- 765-1842.—_ 54375 Main Road • tax 6310650217 \\ P.O.Box 1179 G ',• Q � ro.er.rich-r� • r._ IlaS0t1td.n :US Southold,NY 11971-0959 -k=h i$ • j SEP 1 1 2015 BUILDING DEPARTMENT BLDG DEP( TOWN OF SOUTHOLD TOM or,>c,D I HOLD APPLICATION FOR ELECTRICAL INSPECTION - REQUESTED BY: Date: OV 104 5 Company Name: L v,e ( / 4111 Name: f � � License No.:' Address:. LotA L Phone No.: )) (10 3 JOBSITE INFORMATION: (Indicates required information) *Name: 't1 i--/-vvuutf\ *Address: --- - Jc = *Cross Street: *Phone No.: Permit No.: 0i78- Tax Map District: 1000 Section: Block: I Lot: a, *BRIEF DESCRIPTION OF WORK(Please Print Clearly) ye-4v)— - (Please Circle Ali That Apply) *Is job ready for inspection: YES/ NO Rough In Final *Do•you need a Temp Certificate: YES / NO Temp information (If needed) 'Service Size: 1 Phase 3Phase 100 150 200 300 350 400 Other 'New Service: Re-connect Underground Number of Meters Change of Service Overhead 4dditional Information: PAYMENT DUE WITH APPLICATION 06,./t-)Li 60 4I ° qI82-Request for Inspection Form 1111 g -t 31 ..i., F • _ . ... ‘1. , Gs. .. , n4, qc) . ..,4,„ , _ v ... . b•' - 1 - \ ISW 10GA)40e1 4 • ' i •\ �.f', 1 \ 1....) • ` .4-tg ..--• .r d ,,"` V. J 0 1 \\.. I V . \ 1 Y 0 _ t.. .% 2 0 16 It Yr 0 �l ix. ' G) ca �' r L Is W br7 �o r s• \ A 4ti 0.. q - �� • CA . ••••:. • VA— • i . 's`- pp�o�9 •4t,S• • u) • - ` ,� pay i+ so 1 •0 .44 01 tic tre • 1. - ---- -- - -- ELECTRICAL INSPECTION REQUIRED RETAIN STORM WATER RUNOFF PURSUANT TO CHAPTER 236 APPROVED AS NOTED OF THE TOWN CODE.. DATE:.. J .P.#- i FEEL D & b BY: ._.-.in. ._... .._ NOTIFY BUILDING DEPARTMENT AT 765-1802 8 AM TO 4 PM FOR THE FOLLOWING INSPECTIONS: 1. FOUNDATION - TWO REQUIRED FOR POURED CONCRETE 2. ROUGH - FRAMING & PLUMBING 3. INSULATION 4. FINAL - CONSTRUCTION MUST BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS. COMPLY WITH ALL CODES OF NEW YORK STATE & TOWN CODES AS REQUIRED AND CONDITIONS OF SOLIDIGUlTOWlBA OCCUPANCY OR -JSE IS UNLAWFUL NITHOUT CERTIFICATE JF OCCUPANCY , OI1II- GENERAC® .... . ..., .. . - • . Biliz: 1 (�li GUARDIAN® SERIES Residential Standby Generators Air-Cooled Gas Engine 1 of • INCLUDES: Standby Power Rating • True Power" Electrical Technology Models 006237-0, 006245-0 (Steel - Bisque) -8 kW 60 Hz • Two Line LCD Multilingual Digital Models 006437-1, 006438-2, 006439-1 (Steel - Bisque) - 11 kW 60 Hz Evolution' Controller (English/Spanish/ Model 006720-0 (Aluminum- Grey) 11 kW 60 Hz French/Portuguese) • Two Transfer Switch Options Available: 50 Amp Pre-Wired Switch orCs8 _-�, 200 Amp Service Rated Switch. t 8 ' See Page 4 for Details. t :.--✓ .ice --- • Electronic Governor -' • External Main Circuit Breaker, System Status & Maintenance GENEgAC. ' ,,,__<-,,.,- 52 Interval LED Indicators °° • Sound Attenuated Enclosure • Flexible Fuel Line Connector • • Composite Mounting Pad • Natural Gas or LP Gas Operation D us LISTED • 5 Year Limited Warranty Note CUL certification only applies to unbundled units and units packaged with pre-wired • Capability to be installed within 18" (457 mm) switches Units packaged with the Smart Switch are UL certified in the USA only of a building* *Only if located away from doors,windows and fresh air intakes,and unless otherwise directed by local codes. . FEATURES _ _ w �. _ - .- . �— �__ -.�_ � � - - - _ 0 INNOVATIVE DESIGN&PROTOTYPE TESTING are key components 0 SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION. of GENERAC'S success in "IMPROVING POWER BY DESIGN." But it This state-of-the-art power maximizing regulation system is standard on doesn't stop there. Total commitment to component testing,reliability all Generac models. It provides optimized FAST RESPONSE to changing testing,environmental testing,destruction and life testing,plus testing load conditions and MAXIMUM MOTOR STARTING CAPABILITY by to applicable CSA, NEMA,EGSA,and other standards,allows you to electronically torque-matching the surge loads to the engine, Digital choose GENERAC POWER SYSTEMS with the confidence that these voltage regulation at±1%. systems will provide superior performance. O TRUE POWER" ELECTRICAL TECHNOLOGY: Superior harmonics 0 SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer and sine wave form produce less than 5% Total Harmonic Distortion for network provides parts and service know-how for the entire unit,from the utility quality power. This allows confident operation of sensitive electronic engine to the smallest electronic component, equipment and micro-chip based appliances,such as variable speed HVAC systems. , 0 GENERAC TRANSFER SWITCHES. Long life and reliability are O TEST CRITERIA: synonymous with GENERAC POWER SYSTEMS. One reason for this ./ PROTOTYPE TESTED ' NEMA MG1-22 EVALUATION confidence is that the GENERAC product line includes its own transfer v SYSTEM TORSIONAL TESTED v MOTOR STARTING ABILITY systems and controls for total system compatibility. Lu GENERAC at'•3 �,�y��.� • • * * Mobile EN,,:!:,NED ®e Link SO PROMISE CINEER• �� %no 1R" 20OD •Built In the USA using domestic end torelgn parts. GENERAC® •8/11 kW features and benefits 'Engine J•Generac(OHVI)design Maximizes engine"breathing"for increased fuel efficiency. Plateau honed cylinder walls and plasma moly rings helps the engine run cooler,reducing oil consumption resulting in longer engine life. •"Spiny-lok"cast iron cylinder walls Rigid construction and added durability provide long engine life. •Electronic ignition/spark advance These features combine to assure smooth,quick starting every time. •Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance, less maintenance and longer engine life Now featuring up to a 2 year/200 hour oil change interval. •Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil. •High temperature shutdown Prevents damage due to overheating. Generator •Revolving field Allows for smaller,light weight unit that operates 25%more efficiently than a revolving armature generator. 'Skewed stator Produces a smooth output waveform for compatibility with electronic equipment. •Displaced phase excitation Maximizes motor starting capability. 'Automatic voltage regulation Regulates the output voltage to-±-1%prevents damaging voltage spikes •UL 2200 listed For your safety. Transfer Switch •Fully automatic Transfers your vital electrical loads to the energized source of power. •Pre-wired,color-coded conduits Ensures the easiest,trouble-free installation. (Pre-wired switches only) •Remote mounting Mounts near your existing distribution panel for simple,low-cost installation. _ EvolutionTM Controls •Auto/Manual/Off illuminated buttons Selects the operating mode and provides easy,at-a-glance status indication in any condition. •Two-line LCD multilingual display Provides homeowners easily visible fogs of history,maintenance and events up to 50 occurrences. 'Sealed,raised buttons Smooth,weather-resistant user interface for programming and operations. •Utility voltage sensing Constantly monitors utility voltage,setpoints 60%dropout,80%pick-up,of standard voltage. 'Generator voltage sensing Constantly monitors generator voltage to ensure the cleanest power delivered to the home. •Utility interrupt delay Prevents nuisance start-ups of the engine,adjustable 2-1500 seconds from the factory default setting of 5 seconds by a qualified dealer. 'Engine warm-up Ensures engine is ready to assume the load,setpoint approximately 5 seconds. •Engine cool-down Allows engine to cool prior to shutdown,setpoint approximately 1 minute. •Programmable exerciser Operates engine to prevent oil seal drying and damage between power outages by running the generator for 12 minutes every other week.Also offers a selectable setting for weekly or monthly operation providing flexibilty and lower fuel costs to the owner. "Smart battery charger Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. •Main line circuit breaker Protects generator from overload. -Electronic governor Maintains constant 60 Hz frequency. Unit •SAE weather protective enclosure Sound attenuated enclosure ensures quiet operation and protection against mother nature,withstanding winds up to 150 mph Hinged key locking roof panel for security. Lift-out front for easy access to all routine maintenance items Electrostatically applied textured epoxy paint for added durability. 'Enclosed critical grade muffler Quiet,critical grade muffler is mounted inside the unit to prevent injuries. 'Small,compact,attractive Makes for an easy,eye appealing installation,as close as 18"away from a building. Installation System •1 ft(305 mm)flexible fuel line connector Absorbs any generator vibration when connected to rigid pipe. •Composite mounting pad Eliminates the need to pour a concrete pad unless required by local municipalities. GENERAC® 8111 kW specifications Generator 006437-1,006438-2, 'Model 006237-0,006245-0(8 kW) 006439-1 (11 kW) _ I Rated Maximum Continuous Power Capacity(LP)- —_ ___._ 8,000 Watts' _ 11,000 Watts Rated Maximum Continuous Power Capacity(NG) 7,000 Watts' '10,000 Watts' __ [Rated Voltaga-_ _— -_ 240 _ _�__ �- —240 __---- Rated Maximum Continuous Load Current-240 Volts(LP/NG) 33.3/29.2 45 8/41.7 armonic D Tota -,-,- istortion � __ Less than-5% ,_` Less than 5% Main Line Circuit Breaker 35 IAmp 50 Amp Phase 1_ __.___._______ 1 _ Number of Rotor Poles 2 _ 2 [Rated AC Frequency 60 Hz 60 Hz — J Power Factor 1.0 1 0 Battery Requirement(not included)_ ____ — Group 26R,12 Volts and 525 CCA Minimum a"^1 Unit Weight(Ib/kg) 360/163.3 407/184.6 P Dimensions(L x W x H)in/mm 48 x 25 x 29/1218 x 638 x 7732_ 1 Sound output in dB(A)at 23 ft(7 m)with generator operating at normal load" 62 63 Exercise Duration - _ 12 min 12 min Engine Type of Engine GENERAC OHVI GENERAC OHVI VTWIN Number of Cylinders 1 2 [Displacement 410 cc 530 cc 1 Cylinder Block Aluminum w/Cast Iron Sleeve Aluminum w/Cast Iron Sleeve f Valve Arrangement - Overhead Valve Overhead Valve ___J Ignition System Solid-state w/Magneto Solid-state w/Magneto j Governor System Electronic _( _ Electronic ---1 Compression Compression Ratio 9.5.1 9 51 I Starter _ 12 Vdc 12 Vdc 1 Oil Capacity Including Filter Approx 1.5 qt/1 4 L Approx.1 7 qt/1.6 L [peratmg rpm 3,600 3,600 — 1 Fuel Consumption Natural Gas ft3/hr(m3/hr) 1/2 Load 78(2 21) 124(3 51) Full Load 121(3.43) 195(5.52) Liquid Propane ft3/hr(gal/hr)[I/hr] 1/2 Load 31.6(0.87)[3.29] 42.8(1 18)[4.45] Full Load 51 6(1.42)[5.37] _____ __ 70(1.92)[7.28]_ Note.Fuel pipe must he sized for full load. Required fuel pressure to generator fuel inlet at all load ranges-3 5-7"water column(7-13 mm mercury)for natural gas,10-12"water column(19-22 mm 1 mercury)for LP gas For Btu content,multiply ft3/hr x 2500(LP)or ft3/hr x 1000(NG) For Megajoule content,multiply m3/hr x 93.15(LP)or m3/hr x 37 26(NG). j Controls 12-Line Plain Text Multilingual LCD Display Simple user interface for ease of operation. , 1 Mode Buttons: Auto Automatic Start on Utility failure.Programmable exerciser [-- Manual — Start with starter control,unit stays on.If utility fails,transfer to load takes place. Oft Stops unit Power is removed Control and charger still operate C Ready to RurVMaintenance Messages Standard —1 Engine Run Hours Indication Standard [Programmable start delay between 2-1500 seconds , Standard(programmable by dealer only)._ ___ 1 Utility Voltage Loss/Return to Utility Adjustable(Brownout Setting) From 140-171 V/190-216 V [suture Set Capable Exerciser/Exercise Set Error Warning, — _ Standard _ �`1 Run/Alarm/Maintenance Logs , 50 Events Each [Engine Start Sequence _____—_ — Cyclic cranking.Engine cranks a maximum of five times at factory set intervals and durations. ^] Starter Lock-out Starter cannot re-engage until 5 sec.after engine has stopped, Smart Battery Charger ___.__.._______-._.____...-._. __..._. — _ _ Standard _ .1Charger Fault/Missing AC Warning _ Standard ~_ _ [Low Battery/Battery Problem Protection and Battery Condition Indication � � Standard _ -] Automatic Voltage Regulation with Over and Under Voltage Protection Standard der-frequency/Overload/Stepper Overcurrent Protection- --_� � [ Standard _ 7 Safety Fused/Fuse Problem Protection _ Standard [Alitomahc Low Oil Pressure/High Oil Temperature Shutdown _ Standar _ Overcrank/Overspeed(@ 72 Hz)/rpm Sense Loss Shutdown -�� �� Standard High Engine Temperature Shutdown _ Standard T , Internal FaulVlncorrect Wiring Protection Standard [-common External Fault Capability _ Standard Field Upgradable Firmware Standard "Sound levels are taken from the front of the generator Sound levels taken from other sides of the generator may be higher depending on installation parameters Rating definitions-Standby.Applicable for supplying emergency power for the duration of the utility power outage No overload capability is available for this rating (All ratings in accordance with BS5514,1S03046 and DIN6271) *Maximum wattage and current are subject to and limited by such factors as fuel Btu/megaloulb content,ambient temperature,altitude,engine power and condition,etc Maximum power decreases about 3 5 percent for each 1,000 feel(304.8 meters)above sea level,and also will decrease about 1 percent for each 6°C(10°F)above 16°C(60°F). GENERAC® 8/11 kW switch options Pre-Wired Switch Features Model 006237-0(8 kW) 006437-1(11 kW) •• • Electrically operated,mechanically held contacts No:of Poles___,______w 4 - 2 . a —w . 2 __ 1 for fast,positive connections. Current Rating(Amps) ��� 50 _ — 50 Volg taee iatmg((VAC) • -250 250 7"----1 • Rated for all classes of load,100%equipment Utility Voltage Monitor(Fixed)* rated,both inductive and resistive. -Pick-up 80% 80% -Dropout 60% 60% • 2 pole,250 VAC contactors. [Return to Utility* approx 15 sec approx.15 sec • 30 millisecond transfer time. Exerciser weekly for 12 minutes* Standard Standard • Single coil design 1UL Listed - Standard Standard ,. Total of Pre-wired Circuits 10 12 • Main contacts are silver plated or silver alloy to No 15 A 120 V 3 5 resist welding and sticking. No.20 A120 V 3 3 No 20 A 240 V 1 - • NEMA 1 (indoor rated)enclosure is standard on No.30 A 240 V 1 1 the pre-wired switch, No.40 A 240 V - 1 No.50 A 240 V - - • Pre-wired 30 foot(9.1 meter)whip to connect to !Circuit Breaker Protected' ' ' . the provided 5 foot pre-wired whip and external Available RMS Symmetrical . connection box. - Fault Current @ 250 Volts - 10,000 10,000 • Pre-wired 2 foot(0.61 meter)whip,color coded to *Function of Evolution Controller connect into the existing electrical panel. Dimensions I Mechanical Dimensions ,O —70 0 Height Width Depth I H1 H2 H3 W1 W2 W3 in 185 22.5 22 105 154 14.4 3.8 H2 ° H, mm 470 571.8 558.8 266 7 392 366 97.5 Note.The 50 amp switch is flush mountable.H1 and W1 refer to mounting hole spacing 'ani iii J H2 and W2 are cover dimensions.H3 and W3 are the enclosure dimensions without cover. wI IWire Ranges "Z Conductor Lug Neutral Lug Ground log 50 Amp Switch 1/0-#14 2/0-#14 2/0-#14 m �� Service Rated S.'.'itci>I Features Model _ 006438-2(11 kW) available on 11 kW model only [No.of Poles 2 1 • Electrically operated,mechanically-held contacts for fast,clean connections. Current Rating(Amps) 200 {Voltage_Ratmg_(VAC)_ ' 250 1 • Rated for all classes of load, 100%equipment rated,both inductive and resistive. utility Voltage Monitor(Fixed)* • Service equipment rated,dual coil design. -Pick-up 80% -Dropout 60% • Rated for both aluminum and copper conductors. [Returnto tiblity* approx.'13 sec. .— 1 • NEMA/UL 3R aluminum outdoor enclosure. Exercise weekly for 12 minutes*_ Standard UL Listed Standard _7 • Main contacts are silver plated or silver alloy to resist welding and sticking. Enclosure Type NEMA/UL 3R iWithstand Rating_(Amps) ' 22,000 Lug Range 250 MCM-#6 *Function of Evolution Controller Wi Dimensions 200 Amps 120/240,1e Open Transition Service Rated Height Width H2 "' H1 H2 Wi W2 Depth in 27 24 30 0 11.4 13.5 7 09 mm 692.0 762 4 289.0 343,0 180.0 -- DEPTH- W2 GENERAC® 1 8,/11 kWavailable accessories LModel# Product :, Description Generac's Mobile Link allows you to check the status of your generator from anywhere that you 006463-3 Mobile Link"' have access to an Internet connection from a PC or with any smart device.You will even be notified when a change in the generator's status occurs via e-mail or text message. 005819-0 26R Wet Cell Battery AEvery standby generator requires a battery to start the system.Generac offers the recommended 26R wet cell battery for use with all air-cooled standby product excluding PowerPact®. If the temperature regularly falls below 32°F(0°C),a cold weather kit Is required to maintain 006212-0 Cold Weather Kit optimal battery and oil temperatures.Kit consists of a battery warmer and oil filter heater with built-in thermostats. 005621-0 Auxiliary Transfer Switch The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electri- Contact Kit cal load you may not need.Not compatible with 50 amp pre-wired switches. The fascia base wrap snaps together around the bottom of the new air cooled generators.This 005839-0 Fascia Base Wrap Kit offers a sleek,contoured appearance as well as offering protection from rodents and insects by covering the lifting holes located in the base. If the generator enclosure is scratched or damaged,it is important to touch-up the paint to protect 005703-0 Paint Kit from future corrosion.The paint kit includes the necessary paint to properly maintain or touch-up a generator enclosure 006482-0-8 kW I Scheduled Maintenance Kit Generac's scheduled maintenance kits provide all the hardware necessary to perform complete 006483-0-11 kW routine maintenance on a Generac automatic standby generator Completely wireless and battery powered,Generac's wireless remote monitor provides you with 006664-0 Wireless Remote Monitor instant status information without ever leaving the house.Not compatible with CorePower or EcoGen systems. Smart Management Module Smart Management Modules are used in conjunction with the Automatic Transfer Switch to 006873-0 (50 Amps) increase its power management capabilities.It provides additional power management flexibility (50 _ � not found in any other power management system. __ _ dimensions & UPCs Dimensions shown are approximate Refer to installation manual for enact dimensions DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES, 637.6 mm [25 1 in] 1218 mm [47 9 in] \� 1 •, Op 0— Model UPC 006245-0 696471062458 T___ ii 006237-0 696471062373 .t+� 3si , I �, i 006439-1 696471064391 731.9 mm 'AMMO- .� I� [266'n] O �Et,, 006437-1 696471064377 e006438-2 696471064384 It. 006720 0 696471067200 0 0 • - • 642 mm [25 3 mj 1226 mm [48 3 in] LEFT SIDE VIEW FRONT VIEW GENERAC• Generac Power Systems,Inc. • S45 W29290 HWY.59, Waukesha,WI 53189 •generac.com - .1 ©2015 Generac Power Systems,Inc,All rights reserved All specifications are subject to change without notice Bulletin 01979808BY-K Printed in U S A 04/14/15