Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
39927-Z
Vs116FD1/�G� Town of Southold 10/28/2015 G \ P.O.Box 1179 t 3 53095 Main Rd , Zot 40 ` Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 37867 Date: 10/28/2015 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 2420 Indian Neck Ln,Peconic SCTM#: 473889 Sec/Block/Lot: 86.-4-6.6 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore Med in this office dated 6/4/2015 pursuant to which Building Permit No. 39927 dated 7/8/2015 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: ROOF-MOUNTED SOLAR PANELS TO AN EXISTING ONE FAMILY DWELLING AS APPLIED FOR The certificate is issued to Meyer,John of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 39927 09-30-2015 PLUMBERS CERTIFICATION DATED f Authorized Signature c �a���� cTOWN OF SOUTHOLD 4BUILDING DEPARTMENT .a'‘,' TOWN CLERK'S OFFICE o, ! SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 39927 Date: 7/8/2015 Permission is hereby granted to: Meyer, John PO BOX 540 Southold, NY 11971 To: Install roof-mounted solar panels as applied for. At premises located at: 2420 Indian Neck Ln, Peconic SCTM # 473889 Sec/Block/Lot# 86.-4-6.6 Pursuant to application dated 6/4/2015 and approved by the Building Inspector. To expire on 1/6/2017. Fees: SOLAR PANELS $50.00 ELECTRIC $100.00 CO -ALTERATION TO DWELLING $50.00 Total: $200.00 1. g Inspector �., %®F SOUTH® Town Hall Annex `�� ~® l0 Telephone(631)765-1802 54375 Main Road i � 4 Z Fax(631)765-9502 P.O.Box 1179o Q A�� Southold,NY 11971-0959 .o �� roger.richert(a�town.southold.ny.us � yCOUNTY,NE;;� -- BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION Issued To: John Meyer Address: 2420 Indian Neck Lane City: Peconic St: New York Zip: 11958 Building Permit#: 39927 Section: 86 Block: 4 Lot: 6.6 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: R&B Quality Electric License No: 33592-ME SITE DETAILS Office Use Only Residential X Indoor Basement Service Only Commerical Outdoor X 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures HID Fixtures Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel NC Blower Range Recpt Fluorescent Fixture Pumps Transformer Appliances Dryer Recpt Emergency Fixtures Time Clocks Disconnect Switches Twist Lock Exit Fixtures TVSS Other Equipment. 9.900 kw Photovoltaic System To Include 33-LG Solar Group LG300NIC 300 Watt Panels, With M250-60-2LL Micro Inverters,NC Disconnect,Combiner Box Notes: Inspector Signature: Date: September 30, 2015 7 Electrical 81 Compliance Form.xls U Ecological Engineering ®17 Law Oskn Town of Southold Building Department 54375 Route 25 Southold,New York 11971 RESIDENTIAL PHOTOVOLTAIC PANEL POST-INSTALL CLOSEOUT Project Overview: Project Location:2420 Indian Neck Lane;Peconic,NY Date : 07-29-2015 Owner Name :John Meyer Project#: 15-129 PV Panel Model :LG300N1C-B3 (300w) #of Panels : 33 Approved Mounting System:Unirac SolarMount rail Total System Power: 9.90 kW On April 21,2015 we inspected the completed rooftop PV panel installation at the above- mentioned residential property. The installation is in significant compliance with the filed plans (dated 04-29-2015)and conforms to the 2010 NYS Residential Code. Sincerely, �1 E W y Tahir Qureshi,P.E. k, uF F��'�r r/ ,♦' 1y a cS<<\e) 4V0 071' p� , PROFESS 0r. / ' ' 1 (Y:: JUL 31 2015 ,� D P.O. Box 1346; Stony Brook, NY 11790 • 631-751-0858 • shawn@ecologlicalplanner.com I. .- , . i 1 _. • . FIELD INSPEM4N REPORT DATECON NEMTS , ._ - alb . •-n pU D,� orr(1sT) . . „LI , .ter.m.irm , 4 FOUNDATION(2ND) „ r trt . . .. u, • 4...W .,.� _4, N p I ... • C/) ROUGH FRA.M1NG& .. ' —'\ 1 PLUN7BT1IG -= • -r w .. .. Z . INSULATION PER N,Y. '-""''�"` . *;"...... H ' - STATE ENEYtG'Y CODE .. . . , _ , ' ' _ r .1 ' • .....- . . . . _ ' . .-*-.' • .. .. - . - , ..`., -. ....: . . L,, , r�U • .. ... . 5-- . • 1 , 1 .11 . ...,' _ FINAL • 1 . . r a . r z . *A TS 711 �1d� �'1 , z • m • 1 . • • M 2.. ,... . ., i.„...., . ..., . 1. . . . ., , ,,_, i .. . . . , _ _ . ... is , . Is:" . . . 1 J o V TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD, NY 11971 4 sets of Building Plans TEL: (631) 765-1802 Planning Board approval FAX: (631) 765-9502 �L/ l� )-1 2----- Survey SoutholdTown.NorthFork.net PERMIT NO. I Check Septic Form ---,: [ ll �� y, N.Y.S.D.E.C. 9 11 ! Trustees I , C.O Application -3 201 ;J, Flood Permit Examined 7 gt ,20 is Single&Separate Storm-Water Assessment Form ;C";.i.., ;Epi,:` .. ) Contact: e._ Approved 7 20 ) Mail to.c ��� 1 y(1"1i1C VI,i1 Disapproved a/c ►0"1 ®cikw1k Ln- UU. Kat 2Lt5' Phone C- ``` 0 c1-F Expiration 1 te I ,201_7 A! ` II Li. Bui •g Inspector APPLICATION FOR BUILDING PERMIT Date du n e- I , 20 (5- INSTRUCTIONS a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans, accurate plot plan to scale.Fee according to schedule. b Plot plan showing location of lot and of buildings on premises, relationship to adjoining premises or public streets or areas, and waterways. c The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize, in writing,the extension of the permit for an addition six months. Thereafter,a new permit shall be required APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York,and other applicable Laws, Ordinances or Regulations,for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances,building code,housing code, and regulations,and to admit authorized inspectors on premises and in building for necessary inspections. Ir_) (Signature of appl ant o ame,if a corporation) \c 1 pcurtr/4.\,(d) - . Ii (Mailing address of applicant) Oki/ Irtle State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder t441. k Name of owner of premises 13-11 M�eI (As on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer (Name and title of corporate officer) Builders License No. Plumbers License No. Electricians License No. 33 592 ME-- Other �Other Trade's License No. 1. Location of lnd oq which prppp�osed_work will be done: 2 43- ail /3€ac L& ,e peC=on.cc House Number Street Hamlet County Tax Map No. 1000 Section 3 (o Block 11 Lot 1 •�O Subdivision Filed Map No. Lot 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy b. Intended use and occupancy 3. Nature of work(check which applicable): New Building Addition Alteration ') Repair Removal Demolition Other Work .�f _)[01_./ (Description) 4. Estimated Cost At Zo1boo Fee (To be paid on filing this application) 5. If dwelling, number of dwelling units Number of dwelling units on each floor If garage, number of cars 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of existing structures, if any: Front Rear Depth Height Number of Stories Dimensions of same structure with alterations or additions: Front - Rear Depth Height Number of Stories 8. Dimensions of entire new construction: Front Rear Depth Height Number of Stories 9. Size of lot: Front Rear Depth 10. Date of Purchase Name of Former Owner / /I 11. Zone or use district in which premises are situated PN C.C . • 9 a h(ff S Lib o75. IF. ..) - 12. Does proposed construction violate any zoning law, ordinance or regulation? YES NO 13. Will lot be re-graded? YES NO Will excess fill be removed from premises? YES NO (\ P.5' Address • ; i 25T- 21-1 1 14 Names of Owner of pre ises J � � Pho�e N . rr� - 41- '�6\ -15( -a6 Name of Architect p�p�10_9(co, �I' cf t✓�P.e��l�jAddress �(, - • Name of Contractor n*3 t uc�1,L 1 r 41-i.C /Address -Z ,; R : .(Phone No. 4(7 `U 3 g—c9 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO * IF YES, SOUTHOLD TOWN TRUSTEES &D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO V * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey,to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below,must provide topographical data on survey. 18. Are there any covenants and restrictions with respect to this property? * YES NO rY * IF YES„PROVIDE A COPY. STATE OF NEW YORK) SS. COUNTY OhSUceh 11z) & Ll"-- ` ivt ,LL V\ being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)He is theAv'IVA:t (Contractor,Agent,Corporate Officer, etc.) of said owner or owners, and is duly authorized t�q,,Jerform or have performed the said work and to make and file this application; that all statements contained in this applicatige0..ttiN to ihe0fl ldns knowledge and belief,and that the work will be performed in the manner set forth in the ap j s filed t ,'�4$4 StaceofNewYort - s -- *_ No.010Rb280392 1• Qualified in Suffolk County Sworn to fore me th' •�•'',,,' "';;:',,.0's; ‘ .mission Expires 05/13/2017 1)-tfA 4A7N_____VI06110.an u!-grub ..f 7,,,,..,,,—*\ .s.: Notary Public , =,ya ...ls ,•,= Signature of , pplicant R&B Quality Electric 16316765774 p.1 ISO nd • 1' ,, <o . Town Hall Annex 0 *i Telephone(63])765-1802p 54375 Main Road �,�(631 76.5 95 lP� P.O.Box 1179 Q roger rlChert(N_[OWtI. 0 0 .ny.uS Southold,NY 11971-0959 IX 4,/`?.ol eari BUILDING DEPARTMENT 1 TOWN OF SOUTHOLD APPLICATION FOR ELECTRICAL INSPECTION REQUESTED BY: Ryan Surdi _ Date: uyvi,4 q/ S Company Name: R&B Quality Electric ''�� '' Name: Ryan Surdi . - License No.: 33592-ME • Address: - 663 Waverly Ave Holtsville NY 11742 Phone No.: - 631-447-0350 • JOBSITE INFORMATION: (*indicates required information) *Name: John Meyer 1. *Address: 2420 Indian Neck Lane, Peconic NY 11958 *Cross Street: Leslie Road *Phone No..: 631-447-0350 Permit No.: - 9 9011 Tax-Map District: 1000 , Section: C - - Block: 1/ Lot: 6 . 6 *BRIEF DESCRIPTION OF WORK(Please Print Clearly) -Installed a 9,900 kW roof mounted - solar array. 33 LG Solar Group LG300N1C-G3 300 watt panels 33 Enphase Energy M250-60-2LL Micro r - inverters. (Please Circle All That Apply) *Is job ready for inspection: YES/ NO Rough In c Final *Do you need a Temp Certificate: ` YES O - i Temp Information(if needed) *Service Size: 1 Phase 3Phase 100 150 200 300 350 _ 400 Other *New Service: Re-connect Underground Number of Meters Change of Service Overhead Additional Information: PAYMENT DUE WITH APPLICATION . _ r 82=Request for Inspection Foran - Ecological Engineering Lon • island Town of Southold Building Department 54375 Route 25 Southold,New York 11971 RESIDENTIAL PHOTOVOLTAIC PANEL PROTECT SUMMARY Project Overview: Project Location: 2420 Indian Neck Lane;Peconic,NY Date : 04-29-2015 Owner Name :John Meyer Project#: 15-129 PV Panel Model : LG300N1C-B3 (30Ow) #of Panels : 33 Approved Mounting System:Unirac SolarMount rail Total System Power: 9.90 kW Design Criteria: NYS Residential Building Code: 2010 ASCE : 07-05 NDS for Wood Construction: 2012 NFPA 70: 2008 Ground Snow Load : 2Opsf Wind : 120 mph Seismic Category : C Weathering:Severe Exposure Category: B Termite:Moderate to Heavy Frost Line Depth : 36" Winter Design Temp: 10°F Roof Structure: Stories : 1 Year Built : 2014 Ridge : 1-7/8"x 14"LVL Rafters: 2x10 @ 16"o.c. Ceiling Joists: 2x10 @ 16"o.c. Sheathing: Plywood Wall Framing: 2x6 @ 16"o.c. Roof Surfaces Used: 1 Roofing:Asphalt Shingles(1 layer) Roof Angle of Installed PV Array:40° Reinforcement Required:No. The roof structure,as built,will support the additional loads created by PV equipment. Professional Engineer on record: Tahir Qureshi NYS icense# : 071333 t tt /4- is:s, ;rte am, ` x , �.'!`®\• 0- 9 • P.O.Box 1346; Stony Brook,NY 11790 • 631-751-0858 • shawn@ecologlicalplanner.com r . , 67- Life's Good Mond .. . ....:.. TM N0ON . . LG300N1C-G3 . _ 0LG Electronics,Inc.(Korea Exchange:06657.KS)is one of the globally leading companies and urn ' i MM : ' technology innovator for electronics,information and communication products.The LG Electronics swum ; currently employs more than 91,000 people worldwide in 117 companies.In fiscal year 2011, : ®1110 ; ,, 48.97 billion USD of revenue was achieved. LG is one of the world's largest manufacturers of mobile phones,flat screen TVs,air conditioners, 11111111. r ; Imo ion washing machines and refrigerators.As a future- ®®MV oriented company, LG enables others to use ii leitechnology consisting of renewable energies. LG's high quality solar products are being j ' 111111111 manufactured in LG's leading production facility MMM in South Korea. .11-i" APPROVED PRODUCT C -V us CE �,�5 NUflU : KM 564573 BS EN 61215 �''jr"tr' f }r , Photooltaie Modules rI J p �rig11 �I '((/����, n {{��,7 4.74 ,)0' L LG's High Efficient Cell Technology '''''4°'® i 44 Convenient Installation O. Driven by LG's own N-type technology,LG's high- ,L LG modules are carefully designed to benefit rIN efficiency modules will provide customers with installers by allowing quick and easy installations Convenient Cell Technology high economic benefits lnstailation throughout the carrying,grounding,and connecting stages of modules p Light and Robust 100% EL Test Completed L"J With a weight of just 16 8 kg, LG modules are i-]rJ� All LG modules pass Electroluminescence Light Weight proven to demonstrate outstanding durability -V inspection This EL inspection detects cracks and EL Test against external pressure up to 5400 Pa other imperfections unseen by the naked eye Reliable Warranties Positive Power Tolerance LG stands by its products with the strength of a Q LG provides rigorous quality testing to solar Linear Warranty global corporation and sterling warranty policies ° modules to assure customers of the stated power LG offers a 10 year product limited warranty and a Positive Power outputs of all modules,with a positive nominal 25 year limited linear output warranty. Tolerance tolerance starting at 0% MOrlo.X NeoN ° LG300N1C—G3 0 Mechanical Properties 0 Electrical Properties(STC*) Cells6 x 10 300W --------------------- ---- - Cell vendor LG MPP voltage(Vmpp) 32 0 --__-----_--- _ ___--_-- _- MPP current(Impp) 946 Cell type - - - -- Monocryst --- -- - - - Cell dimensions 156 x 156 mm/6 x 6 in __-- _-'- -_- ' -""" - -"------- -- -- ------- -- Open circuit voltage(Voc) 39 5 #ofbusbar 3 - Dimensions(L x W x H) 1640 x 1000 x 35 mm Short circuit current(Isc) 1005 64.57 x 39.37 x 1.38 in Module efficiency(%) 18 3 Static snow load__ -_ _ _5400 Pa/113 psf Operating temperature(°C) -40-+90 Static wind load 2400 Pa/50 psf - Maximum system voltage(V) 600(UL),1000(IEC) Weight 16_8±0 5 kg/36.96 11 lb —_--.... ----__--- ± Maximum series fuse rating(A) 20 Connector type MC4 connector IP 67 —-___--- Power tolerance(%) 0-+3 Junction box IP 67 with 3 bypass ass diodes •STC(Standard Test Condition)Irradiance 1000 W/mr,module temperature 25`C,AM 15 Length of cables _ 2 X 1000 mm/2 x 39 37 In— — •The nameplate power output is measured and determined by LG Electronics at its sole and absolute discretion Glass High transmission tempered glass ------ --- -- - ---------------- ------------- Frame Anodized aluminum 0 Electrical Properties(NOCT*) ® Certifications and Warranty 300W Maximum power(Pmpp) 221 Certifications IEC 61215,IEC 61730-1/_2,UL 1703, MPP voltage(Vmpp) 29 3 --------- - 90 1, ISO-------- -IEC 61701 MPP current(Impp) 755 Product warranty 10 years Output warranty of Pmax Open circuit voltage(Voc) 365 (measurementTolerance t 3%) Linear warranty* Short circuit current(Isc) 809 •1)1st year 97%,2)After 2nd year 07%annual degradation,3)802%for 25 years Efficiencyreduction (from-1000 W/mz to 200 W/m) <4 5 •NOCT(Nominal Operating Cell Temperature)Irradiance 800 W/mz,ambient temperature 20•C, 0 Temperature Coefficients wind speed 1 m/s NOCT 45±2°C 10/040 10/040 Pmpp -0.42%/°C 0 Dimensions(mm/in) -11 Voc -0 31%/°C Isc - --- -- -- - - -003%/'C- w c r(‘ s- 5 Characteristic Curves 1000/3937 20/110 22/007 55.4 o(X 140.4 Drain ndad400) Long side frame Short side frame VC 10 1000 W 4 5 •l°14 ct be,.eee 00•010091,010,4enog1,010,41,010,4tie "'C F 9- actor h°1ea(4n) (DIM. E - r '58- 800W 7 1z- /•,6- 600W t Grwrone bw002ea) ;(.) (•) 5- 8.08.0(Zad / 400W woe.,laigi°.) r 4 1 3 _ 200 W 2 -' A n j 1000/3937 \ o Ghl°t°/198/1 -. 5 10 15 20 25 30 35 40/oitage(V) V m5/006 140 , — Dafen% 1 4 40/16 A 120 e 2 2 . r;100 Isc fri > . .. P. li 80 Voc Daronr ."-_ """--- --- 944/3717 I 08/031 60 Pmax .II 40 �.ad011111111,11111 1 Dern z 20, 111111111, 11101111 I 0 - - - 35/138 -40 -25 0 25 50 75 90 Temperature(•C) •The distance between the center of the mounting/grounding holes Cji.: North America Solar Business Team Product specdreatrons are subject to change v dtout notice El •r, El La LG Electronics USA Inc "LG Life's Good"is a regdstrated trademark of LG Corp 1000 Sylvan Ave,Englewood Cliffs, All other trademarks are the property of their respective owners y1, ki NJ 07632 DS-N-60-C-US-F-EN-30520 .. ;• . Life's Good Contact Ig solar@Ige corn Copyright©2013 LG Electronics All nghts reserved 0 ' i www lgsolarusa corn 05/01/2013 , Enphaseg Microinverters En p hase® M250 . ,Gh �p ,_____„„_......0_,....„...4.,„,...0,„_„...1 ,,,,,,,,,,.,.u,,,,,,,' ' ,,,..-_-.:-- ., r___., ______________ 4; - 'C`GEPD apex, -,,'0,-' ' '- "- . , r: !fj a9 ,.yv rte.-r. The Enphase® M250 1.?icroinverter delivers increased energy harvest and reduces design and installation complexity with its all-AC approach. With the M250, the DC circuit is isolated and insulated from ground, so no Ground Electrode Conductor(GEC) is required for the microinverter.This further simplifies installation, enhances safety, and saves on labor and materials costs. The Enphase M250 integrates seamlessly with the Engage®Cable, the Envoy®Communications Gateway'', and Enlighten®, Enphase's monitoring and analysis software. PRODUCTIVE SIMPLE RELIA= LE -Optimized for higher-power - No GEC needed for microinverter -4th-generation product modules - No DC design or string calculation - More than 1 million hours of testing -Maximizes energy production required and 3 million units shipped -Minimizes impact of shading, -Easy installation with Engage -Industry-leading warranty, up to 25 dust,and debris Cable years [e] nphase® a JENE R G Y C US ® ' 1 1 En phase®M250 Microinverter//DATA INPUT DATA(DC) M2507.607.2LL-S22/S23/S24 .Recommended input power,(STC)^ '" 210',-300 W 'LL '._. _. Maximum input DC voltage 48 V Peak power tracking.voltage • 27 V-39,V Operating range 16 V-48 V .Min/Max start voltage 22 V/48 V ... ._i. a_ , Max DC short circuit current 15 A Max,input,current . ' - • 9.8 A , . _ OUTPUT DATA(AC)_ 4 - m^ 03208 VAC _® - ¢ @240 VAC __ Peak output power" 250 W,° 250 W Rated(continuous)output power 240 W 240 W Nominal output current 115 A(A rms at nominal_duration) 1.0 A(A rms at nominal duration) • ' Nominal voltage/range 208 V/183-229 V 240 V/211-264 V Nominal frequency/range=- 60. 0/57-61 Hz 60.0/57-61 Hz Extended frequency range* 57-62.5 Hz 57-62.5 Hz Power factor - >0.95 >0.95 Maximum units per 20 A branch circuit 24(three phase) 16(single phase) Maximum output fault current 850 mA rms for 6 cycles . 850 mA rms for 6 cycles EFFICIENCY CEC weighted efficiency,240 VAC - , 96.5% - ' , CEC weighted efficiency,208 VAC 96.0% Peak inverter efficiency 96.5/0 , Static MPPT efficiency(weighted,reference EN50530) 99.4% Night time,power consumption • . , 65 mW max .- .` ___. _•. , __.-._ _ ___ _ _ - _. -. __ _ .__ - MECHANICAL DATA Ambient temperature range =40°C to+65°C ." . Operating temperature range(internal) -40°C to+85°C Dimensions(WxHxD) . -'171 mm x 173 mm,x 30 mm(without mounting bracket) , Weight 2.0 kg Cooling - Natural convection-No fans' ,- s... Enclosure environmental rating Outdoor-NEMA 6 ..... FEATURES. ' Compatibility 'Compatible with 60-cell PV modules. - ' . Communication Power line Integrated ground . . The'DC circuit meets the-requirements for ungrounded PV arrays in , • . . '- NEC'690.35.Equipment"ground is provided in the Engage Cable.No _' additional'GEC or ground is required. ' ' Monitoring Free lifetime monitoring via Enlighten software Compliance , P UL1741/IEEE1547,FCC Part 15 Class B,CAN/CSA-C22.2 NO.04.461,, . 0.4-04,and 107.1;01 -. *Frequency ranges can be extended beyond nominal if required by the utility To learn more about Enphase Microinverter technology, r ;, enphase® visit enphase.com L J E N E R G Y ©2013 Enphase Energy.All rights reserved.All trademarks or brands in this document are registered by their respective owner. 4. --''4* L __ _.__ _ _ _ _______________ _ ______ _ _ _ _ _ __ _ ___ ...........,_____ _ _ _ _ _ _ _ ___ ______ __ ____ ______ = =___ =_,= .__ _.=___ :__ _ ___.,__...____. _____ , . . . . . _ ,:,--_,,,,,,,,.-5-,,Nz,..,==-_,..,:„--,_-_,..__-_-„ _ . _ . - _._, ,,,,'W--%.":"..--t.: „."..,r_.,„...4.---t : - _ ...'-,-.,,V- ------ ----7.---,------ -,,,...., =-r..a --*-7..._-_ . _ ... w,_ _ - Id ..�,_ one of the globally leading companies and 110_4—_ `_ 'cam technology innovator for electronics,informanol l > = g and communication products.The LG Electronics ni 1az y .:7: .7 LG is one of the world's largest manufacturers of -'-r>+ mobile phoirlci nes;flat screen TVs,air conditioners, , .1 t ! ^l-- Y _ -� oriented company. LG enables others to use III , r ' t L t.*f�!vcr consistira of�enewab!e ene�cties, N®®® �`' !` ""'�' —1 LG's high quality solar products are being manufactured in LG's leading production facility 1.1 - in South Korea. ` I Na APPROVED PRODUCT IIIIIIIIIIII ."----- D E C 131 US cE , - t' 3°- 1 111 KM 564573 BS EN 61215 Phctowitac Modules - LG's High Efficient Cell Technology ® ' Convenient Installation Driven by LG's own N-type technology,LG's high- LG modules are carefully designed to benefit efficiency modules will provide customers with installers by allowing quick and easy installations high economic benefits throughout the carrying,grounding,and connecting stages of modules MI Light and Robust = '=`, 100% EL Test Completed With a weight of just 16 8 kg,LG modules are ` 134 All LG modules pass Electroluminescence L J . r; , proven to demonstrate outstanding durability — inspection This EL inspection detects cracks and against external pressure up to 5400 Pa other imperfections unseen by the naked eye Reliable Warranties - Positive Power Tolerance '�'��-t�'? LG stands by rts products with the strength of a a�%�s>44:v LG provides rigorous quality testing to solar global corporation and sterling warranty policies IIIII modules to assure customers of the stated power LG offers a 10 year product limited warranty and a - - outputs of all modules,with a positive nominal 25 year limited linear output warranty tolerance starting at 0% e 1 `_g m% ,� +r�. Y 1 a. txib ;•..v k ,N 4 01 Y�� ` 4),..-4),',14�4, a . ‘.. - .. 'AV-',sx A "b'g'. T,` 1'1 SS i ,,A ' ''` , t irt" i' � 0. .e .. i�$.... �¢ xsb t :'r t. t k t / i° +a a r f t'"F.'4 .AA 'ale ''r' 'ev kr #�° Qtr°�� �� y� ���r��t�. 5 �,����`�a�z���� ,ti�e�,:,r;,�r' 3-,:v.,14,,,,,�� s� "�,"�< �' �'`�� r @r»�� �t-�r�`4. q' '�„ t `Sa „,*'4,- • ;'t# +» ;,�di-t `'-rrJ s 14'c t,k stt e� a v y !-•.:77,:i',. ,t� z k;1' G oit t- M't N,` '”""t` 1 ,�,;',t ki �" yk"0„ .+ . F,,r- 4' r,, fz`" T, t K s- "s, y+-,;r(,' .r i' r„� 4 a K71 w"i, ^,' e lar s ,, v” "" - /' '. „1tr��p a s i : l 3 a",t ,:r r : /" t r g r� k . „ , ® Mechanical Properties ®Electrical Properties(STC') Cells 6x10 300W Cell vendor LG - MPP voltage(Vmpp) 32 0 Cell type ., Monocrystalline MPP current(Impp) 9 46 Celldimensions 156 x 156 mm/6 x 6 in _ ' #of busbar 3 Open circuit voltage(Voc) 395 Dimensions(L x W x H) 1640 x 1000 x 3.5 mm Short circuit current(Isc) 1005 64 57 x 39 37 x 138 in Module efficiency(%) 18 3 Static snow load - -_ 5400 Pa/113 psf Operating temperature(°C) -40-+90 ' Static wind load2400 Pa/50_psf _ _ Maximum system voltage(V) 600(UL),1000(IEC) Weight _ 168±05 kg/3696±11l6 Maximum series fuse rating(A) 20 Connector type ., MC4 connector IP 67 Junction box IP 67 with 3 bypass diodes Power tolerance(%) 0-+3 •STC(Standard Test Condition)Irradiance 1000 W/ma,module temperature 25°C,AM 1 5 Length of cables 2 x 1000 mm/2 x 3937 in •The nameplate power output is measured and determined by LG Electronics a1 its sole and absolute discretion Glass High transmission tempered glass Frame Anodized aluminum ®Electrical Properties(NOCT') ® Certifications and Warranty 300W Maximum power(Pmpp) 221 Certifications IEC 61215,IEC 61730-1/-2,UL 1703, MPP voltage(Vmpp) 293 ISO 9001,IEC 61701 - MPP current(Impp) 755 Product warranty 10 years Open circuit voltage(Voc) 36 5 Output warranty of Pmax (measurementTolerance±3%) 'Linearwarranfy' fl09 Short circuit current(Isc) -1)1st year 97%,2)After 2nd year.07%annual degradation,3)802%for 25 years Efficiency reduction <4 5 (from 1000 W/ma to 200 W/mr) •NOCT(Nominal Operating Cell Temperature) Irradiance 800 W/m',ambient temperature 20°C, el Temperature Coefficients vend speed 1 m/s NOCT 45±2°C ,0/040 10/0.40 0 Dimensions(mm/in) H H Pmpp 0.42%/°C Voc - - -0.31%/°C ti Isc - 003%/°Cc rl —r* Characteristic Curves 100073933 26ptO 22/07;1 5 5'40 006.4 oa,4 h4wi4.a) Long side frame Short side frame Q 10 1000 W 4.0.1-5 4..0 c 9- Oran°h°i..(44a) 055f6655 be ween mn,wrn9 64154 1e71 8- 800 W 1I IES o - 186:71U 7 12-il43 l \ 6 600W Growl iolm2Z.a1 (4 (•) 11 5 B-08 OIL i 499- Mounting ..ia•.tI 200 W 2 / 1000/3933 1 \, .......___CL Gble15655, 5 10 15 20 25 30 35 40/oitage M 111.5/006 Wad X 140 a I t 3 40/016 • 120 �'v g too Iscilt eVoc Det 55Y 80 - - - -- ------ ---. r 944/3m ae7ojl Pmax ���11 1 re Ii 011[1 t��11 0�'fl011140 11') (?5--- Dead 0 35/138 -40 -25 0 25 50 75 90Temperature(•C) •The distance between the center of the mounting/grounding holes °'° LG North America Solar Business Team Product specifications are subject to change wdhout notice 0 •s, 0 L LG Electronics U S A Inc LG Ufe's Good"is a regisi ated trademark of LG Corp r 1000 Sylvan Aye,Englewood Cliffs, All other trademarks are the property of thee respective owners • NJ 07632 DS-N-60-C-US-FEN-30520 • 0 Contact Ig solarelge corn Copyright©2013 LG Electronics All nghts reserved Q • ,i Life's Good wwwlgsolaruse corn 05/01/2013 Enphase®Microinverfers Enphase® M250 a 11 , y k ry v i - ali'��'4�''�'r ,�' - Pa2 ,11Unr===CC 1=C..&� =rFa.... +thle.w ZITe.:[_r174-.3irw .65:128YIk. .^.b 7..."=4,CST AUFIC`=Ptrc*+^,x. The Enphase M250 Microinverter delivers increased energy harvest and reduces design and installation complexity with its all-AC approach. With the M250, the DC circuit is isolated and insulated from ground, so no Ground Electrode Conductor(GEC) is required for the microinverter.This further simplifies installation, enhances safety, and saves on labor and materials costs. The Enphase M250 integrates seamlessly with the Engage®Cable, the Envoy®Communications Gateway', and Enlighten®, Enphase's monitoring and analysis software. PRODUCTIVE SIMPLE RELIABLE -Optimized for higher-power -No GEC needed for microinverter -4th-generation product modules -No DC design or string calculation - More than 1 million hours of testing - Maximizes energy production required and 3 million units shipped - Minimizes impact of shading, -Easy installation with Engage - Industry-leading warranty,up to 25 dust, and debris Cable years enphase© c us 17- Enphase®M250 Microinverter II DATA INPUT DATA(DC) M250-60-2LL-S22/S23/S24 Recommended input power(STC) 210-300 W Maximum input DC voltage 48 V Peak power tracking voltage 27 V-39 V Operating range 16 V-48 V Min/Max start voltage 22 V/48 V Max DC short circuit current 15 A Max input current 9.8 A OUTPUT DATA(AC) @208 VAC @240 VAC Peak output power 250 W 250 W Rated(continuous)output power 240 W 240 W Nominal output current 1.15 A(A rms at nominal duration) 1.0 A(A rms at nominal duration) Nominal voltage/range 208 V/183-229 V 240 V/211-264 V Nominal frequency/range 60.0/57-61 Hz 60.0/57-61 Hz Extended frequency range* 57-62.5 Hz 57-62.5 Hz Power factor >0.95 >0.95 Maximum units per 20 A branch circuit 24(three phase) 16(single phase) Maximum output fault current 850 mA rms for 6 cycles 850 mA rms for 6 cycles EFFICIENCY CEC weighted efficiency,240 VAC 96.5% CEC weighted efficiency,208 VAC 96.0% Peak inverter efficiency 96.5% Static MPPT efficiency(weighted,reference EN50530) 99.4% Night time power consumption 65 mW max MECHANICAL DATA Ambient temperature range -40°C to+65°C Operating temperature range(internal) -40°C to+85°C Dimensions(WxHxD) 171 mm x 173 mm x 30 mm(without mounting bracket) Weight 2.0 kg Cooling Natural convection-No fans Enclosure environmental rating Outdoor-NEMA 6 FEATURES Compatibility Compatible with 60-cell PV modules. Communication Power line Integrated ground The DC circuit meets the requirements for ungrounded PV arrays in NEC 690.35.Equipment ground is provided in the Engage Cable.No additional GEC or ground is required. Monitoring Free lifetime monitoring via Enlighten software Compliance UL1741/IEEE1547,FCC Part 15 Class B,CAN/CSA-C22.2 NO.0-M91, 0.4-04,and 107.1-01 Frequency ranges can be extended beyond nominal if required by the utility To learn more about Enphase Microinverter technology, "p enphase® visit enphase.com E N E R G Y ©2013 Enphase Energy.All tights reserved All trademarks or brands in this document are registered by their respective owner /.f a rel -i-.p-, . • • I i'ii`r tii I ; hut tauDATE: (L ,2,.F .# ?z i s i o n S: ROOF SHEATHING FEE: / ,bb B -e WATERPROOFRIASHMOUNT ELECT liCAL UNIRAC SOLARMOUNT RAIL MFTG'D BYQUICKMOUNTPV NOTIFY BUILDING a �r r',rtT1ENT ATINSPVOE i'��i �J'i PEQUAL) 765-1802 8 AM TO 4 'i,. FOR THE �, – 7 .0.4:w ����ii FOLLOWING INSPEO T I NS: --e--- P.V.PANEL �iii� 1. FOUNDATION - TV REOUIRED i }' FOR POURED Cc": RETE �� i' 2. ROUGH - FRAMING El PLUMBING __�___ 2y"EFFECTIVE THREAD LENGTH '�!SP- ' ASPHALT SHINGLES 3. IN";ULATIOi`d RAFTER PENETRATION(MIN.)`�� I ����' 4. FINAL - CO?,IST,=1 IC ;C 1 MUST ATTACHMENT /j � i��G��� BE COMPLETE: ^F' CO. , MEET / 5-6 MAX. 211. TERS@16° . ,efr����i ALL CONTRUC i J f HALL MEET THE 0. i REQUIREMENTS O T. .. u ODDS OF NEW YORK STATE. NOT R SF•U)NSIBLE FOR RAFTER ATTACHMENT SPACING DESIGN OR CONSTRI :TION ERRORS. I 0" . 36'-2" f— FLANGE =1'-0" Engineer of Record: QI_' MOUNTING DETAIL g Scale: 1%Z' = 1'-o" TAHIR QURESHI, P.E. NEW `'OR ~&ITOW ;6 �n 2-3150 Q3 J"; FLANGE NUT AS REQUIRED AN?, CONE)! f0�'S OF Z.Jwy r END CLAMP A O Z 0,`zO m w u... moi, --� Cl= o� _,o `� OP MOUNTING FLANGE NUT --- ----. �_ 16,1Z-4R CLAMP '.' , is u_• V` N vwi .5 R4,1,.. C D z „-:1,W a . ~Q W Q O MID CLAMP .”- - ! �_ I..f. W y y p Z T-BOLT J Z = Jm�,ywm 0 �� >— Q OJ E W3�aor I ��� 4..I.,, � 5/16"Nut--„,.....„.4) p L a E o Y~W . 41,♦♦ ♦♦♦♦ 40, . ♦♦�♦ ♦♦♦ ♦� ♦♦� �♦ ♦♦� ♦ ucc–t � Block pivots on flashing j o { 1f-� J O o� ♦ ♦ 1i♦♦ ♦♦♦� ♦♦i �� CLIP " T ical Ut✓Cl�� tl �Y O �_�y♦♦♦ ♦♦♦ ♦♦♦ with water-tight seal 516 Plot Washer I Q YP �+ w rn 19'-6" :�♦:♦ ♦:♦♦:♦ ♦:♦:♦♦ :♦:♦:♦ :♦:-:♦ ♦:♦:♦:♦ ♦:♦:♦: ♦:♦:I:�♦ ♦:♦:♦:♦ :♦:�♦ 4.RAIIFTER T-BOLT EPDMR h he L foot UvaE 15 UNLA�� � -l.� ._ vo z o W o 0H Z U V ��.. ♦ ♦♦ ♦♦♦, ♦♦ ♦♦♦ ♦♦ ♦♦♦ ♦♦�' 5 16 u herWas r Wii . ♦:.:♦ ♦ ii .. ii♦ \ i♦i♦i♦ i♦i♦i� ' S 16'�Nut .�, ._. WITHOUT CERTIF . ATL E '♦♦♦ ♦♦♦ ♦♦♦ ♦♦♦ ' ♦♦♦♦ ' ♦♦♦ ♦♦♦♦♦ ♦♦♦ 41k.♦♦♦ ♦♦♦♦ ♦♦ 5/16"Sealing Wazher r12'-0" J♦♦♦♦♦♦ ♦♦♦♦♦♦ ♦♦♦♦♦♦♦ ♦♦♦ ♦♦♦♦♦♦ IL SOLARAMOUN� � I�� 'f 0� OCCUPANCY O ♦♦♦♦♦� ♦♦♦�♦♦♦ ♦�♦�♦� ♦♦♦♦�� ♦♦♦: ♦.:♦♦♦♦ ♦♦♦♦♦♦ ♦♦♦♦♦♦♦ ♦♦♦♦♦♦♦ �♦♦♦♦♦♦ ♦♦O - ♦♦♦ Block z , . ♦ . ii ♦♦♦�♦ ♦�iil ♦♦�i♦_ !�i♦♦i ♦i♦•i� ♦♦♦♦ ♦i�♦i ♦•i♦♦ . 41 1 1 Ja" RETAIN s�©13 M WATT RUN( FF o ♦♦♦ / ♦ ♦ ♦ ♦ ♦♦ - 5/16-18 x b Hanger Bolt ii OF THE TOWN CQDE.UANT TO TER 23E ♦♦♦i♦i ♦♦♦i♦i i♦i�i♦i ♦♦i ♦��♦ �i0♦i ♦lii ♦♦♦4 ♦ ♦♦i♦♦i♦: : ♦�♦�♦� 12 k— r—, ' o J ♦♦ �r_♦`♦ �►_ ♦♦♦ ♦ ♦�� ♦♦♦ ��� ,_ ♦ T-BOLT r.r. �-L- Q .,""'- Q ???� ---_♦` i♦i.� ?♦?♦?♦? V � ♦♦�'. ♦♦?♦?♦ - � ���71s♦s♦s♦; .�� ♦`♦1-_ UGC-1 r. 7_..i.. CLIP O Z173 n cf) Pt? Pwt (33)LG300N1C-B3(300W)P.V.PANELSTYPICAL UNIRAC w .OWITH ENPHASE M250 MICROINVERTERS RAIL TYPICAL PV FLASHING COMPONENTSON UNIRAC SOLARMOUNT RAIL SYSTEM TOP MOUNTING CLAMP u- Q O GARAGE ROOF PLAN p UINSTALLATION 0 N Scale: 16" = 1-0" r::::,, a a . co P c pn 12 THE ROOF STRUCTURAL MEMBERS HAVE BEEN CHECKED FOR 120 MPH WIND LOADS BASED ON ASCE 7-05 AND FOR COMPLIANCE WITH THE 2010 NYS o 1. PANELS SPACED 1"APART RESIDENTIAL BUILDING CODE AND THE 2012 NATIONAL DESIGN STANDARDS CD 2. UNIRAC SOLARMOUNT RACKING SYSTEM FOR WOOD. THERE WAS (1) ONE LAYER OF ASPHALT ROOF SHINGLES ti . . . _ . WI RAILS PERPENDICULAR TO INSTALLED AT THE TIME OF OUR INSPECTION. THIS APPROVED PLAN DOES NOT RAFTERS, IN ACCORDANCE WITH CODE APPLY IF ANY ADDITIONAL ROOF SHINGLE LAYERS ARE INSTALLED AFTER OUR 0 COMPLIANT INSTALLATION MANUAL 227.3 SITE INSPECTION. INSTALLATION OF SOLAR PANELS WITH MORE THAN (2) TWOPD -s LAYERS OF ROOF SHINGLE IS NEVER PERMITTED. o 3. MOUNTING BRACKETS TO BE SECURED TO L,� o z CO 111 Co RAFTERS WITH 5%6" STAINLESS STEEL LAG THE MOUNTING BRACKETS & HARDWARE MEET OR EXCEED ASCE 7-05 AND z 0 a BOLTS SPACED 66" O.C. MAX USING STANDARD w c SOLARMOUNT RAILS IN PORTRAIT LAYOUT. 2010 NYS RESIDENTIAL CODE REQUIREMENTS WITH 120 MPH WIND DESIGN. o w >- r o '/ 11'-6" THE SYSTEM'S ATTACHMENT TO THE ROOF TO MEET OR EXCEED NYS CODE w Z z Cl) ii"x14°LVL RIDGE4. INSTALLED PANELS < 6"ABOVE ROOF SURFACE. REQUIREMENTS. Ai 8s, wz0 ,u M 471 S LG300N1C-B3(300W)P.V.PANELS WITH ANY PLUMBING VENTS THROUGH THE ROOF ARE NOT TO BE CUT OR COVERED w o w ENPHASE M250 MICROINVERTERS ON 5. INSTALLED PV SYSTEM < 5# PER SQUARE FOOT. Na >< PLYWOOD SHEATHING " UNIRACSOLARMOUNTRAILSYSTEM DURING PANEL INSTALLATION, ANY MODIFICATION OR RELOCATION OF VENTS N 0 o oG ,, �'�� , '44 6. MINIMUM 18" CLEARANCE PROVIDE ALONG AT WILL REQUIRE A PLUMBING PERMIT AND INSPECTIONS. m �cs,<0 ,%,��s°/6. �' *,� LEAST (1) ONE EDGE OF EACH ROOF RIDGE AND Q ASPHALT SHINGLES o��``� 's'q� ''`�,,, SHALL BE CLEAR OF ANY SOLAR EQUIPMENT, SIZES OF MEMBERS THAT WERE NOT ACCESSIBLE FOR DIRECT MEASUREMENT MI a- (ONE LAYER) r3- "'1", WIRE CONDUIT, ETC. ARE BASED ON OBSERVATIONS OF ACCESSIBLE MEMBERS OR CONSTRUCTION 0 40° 40° DEPTH OR BOTH AND OUR KNOWLEDGE OF STANDARD CONSTRUCTION •� `' `°� ., 7. PV INSTALLATION TO COMPLY WITH ARTICLE 690 , y "''� , OF THE 2008 NATIONAL ELECTRICAL CODE AND PRACTICES AT THE TIME OF CONSTRUCTION. 8._-- 2x10 JOISTS @ 16 O.C. " 4'"'% NFPA 70 (2008). 2x6 WALL FRAMING � ,,, THIS ROOF STRUCTURE, AS SHOWN, IS ADEQUATE TO SUPPORT THE "'�,�, 8. SYSTEM SIZE: 9.9 kW PROPOSED LOADS. to 2 �" o > / / cn N '�..,� NOTE: Z N 1'-o" _ "4 1. CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS PRIOR TO START OF WORK. IF EXISTING CONDITIONS VARY FROM iI; �; ¢ 3 • PLANS, THE CONTRACTOR SHALL STOP WORK AND IMMEDIATELY NOTIFY THE DESIGN PROFESSIONAL. SHOULD THE o �, o SIMPSON H2ACLIP ►i,1,-0� CONTRACTOR FAIL TO CONTACT THE DESIGN PROFESSIONAL AND CONTINUE WORK, THE CONTRACTOR ASSUMES ALL RESPONSIBILITY AND LIABILITY ARISING THEREFROM. © SEAL -f- 2. THE OWNER AND CONTRACTOR SHALL OBTAIN ALL NECESSARY PERMITS, VERIFY ALL EXISTING CONDITIONS, EXAMINE i y 19'-1" )' THESE DOCUMENTS AND BE RESPONSIBLE FOR ALL MEASUREMENTS, DIMENSIONS AND CONDITIONS. ,� I -� igh SECTION 1 3. COMMENCEMENT OF CONSTRUCTION WILL SIGNIFY THAT THE CONTRACTOR WILL HOLD THE DESIGN PROFESSIONAL r,- ,1‘ Scale:e"=1'-0" HARMLESS FOR ANY AND ALL ERRORS, OMISSIONS AND PERSONAL LIABILITY F .. LG MONO X NED \ PHOT _ VOL_ TAIC PANEL SPECS LI\ ''''\‘c MODEL it QTY. LENGTH WIDTH DEPTH WEIGHT •LG300N1C-B3 33 64,57" 39.37" 1.38" 36,96# Project # 15-129 ENPHASE I \ VERTER SPECS MODEL # QTY, MICR❑INVERTER HEIGHT WIDTH DEPTH WEIGHT M250 33 YES 7.0" 8.5" 1,1" 3.66# .3 0 pv 1L 0