Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
39779-Z
4aFFtiicoG Town of Southold 10/23/2015 y P.O.Box 1179 ;�o 53095 Main Rd ,..%l. 4dao, Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 37855 Date: 10/23/2015 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 2290 Harbor Ln, Cutchogue SCTM#: 473889 Sec/Block/Lot: 103.-1-28 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 5/11/2015 pursuant to which Building Permit No. 39779 dated 5/18/2015 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: ROOF MOUNTED SOLAR PANELS TO AN EXISTING ONE FAMILY DWELLING AS APPLIED FOR The certificate is issued to Pfaff,Joseph&Pfaff,Dorothy of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 39779 10-20-2015 PLUMBERS CERTIFICATION DATED s Authorized Signature e guFFot TOWN OF SOUTHOLD �a�yBUILDING DEPARTMENT TOWN CLERK'S OFFICE o 4 SOUTHOLD, NY ‘ ' BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 39779 Date: 5/18/2015 Permission is hereby granted to: Pfaff, Joseph & Pfaff, Dorothy 2290 Harbor Ln Cutchogue, NY 11935 To: Installation of roof mounted solar panels as applied for. At premises located at: 2290 Harbor Ln, Cutchogue SCTM # 473889 Sec/Block/Lot# 103.-1-28 Pursuant to application dated 5/11/2015 and approved by the Building Inspector. To expire on 11/16/2016. Fees: SOLAR PANELS $50.00 Total: $50.00 di-g Inspector Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY • This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings,property lines,streets,and unusual natural or topographic features. 2 Final Approval from Health Dept. of water supply and sewerage-disposal(S-9 form) 3. Approval of electrical installation from Board of Fire Underwriters. 4 Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1%lead. ' 5. Commercial building,industrial building,multiple residences and similar buildings and installations,a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements B. For existing buildings(prior to April 9, 1957)non-conforming uses, or buildings and"pre-existing"land uses: 1. Accurate survey of property showing all property lines,streets,building and unusual natural or topographic features 2. A properly completed application and consent to inspect signed by the applicant If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00,Alterations to dwelling$50.00, Swimming pool$50 00,Accessory,building$50.00,Additions to accessory building$50.00,Businesses$50.00. 2 Certificate of Occupancy on Pre-existing Building- $100.00 3 Copy of Certificate of Occupancy-$25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy-Residential$15.00,Commercial$15.00 Date. 5" $ - l 5 New Construction: Old or Pre-existing Building: (check one) Location of Property: 22(46 kikP-80 _ LAIVr'- (JvTCH GC:Cl F House No. Street Hamlet Owner or Owners of Property. vog ' y `Tr/4 Suffolk County Tax Map No 1000,Section /0 3 Block / Lot 2$r Subdivision Filed Map. Lot: Permit No. Date of Permit. Applicant: Health Dept. Approval• Underwriters Approval: Planning Board Approval. Request for: Temporary Certificate Final Certificate: (check one) Fee Submitted: $ Applicant Signature ,,,,. iii.„.� �,�o��pF S0(/lyol _ Town Hall Annex �� ~ O Telephone(631)765-1802 54375 Main Road ; iligilig Fax(631)765-9502 P.O.Box 1179 A Q ,t .y► o A roger.richertRtown.southold.ny.us Southold,NY 11971-0959 . �` e :(COU l'''� '--..see. I BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE C SITE LOCATION Issued To: Pfaff Address: 2290 Harbor Lane City: Cutchogue St: New York Zip: 11935 Building Permit#: 39779 Section: 103 Block: 1 Lot: 28 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE .Contractor. DBA: North Electric LLC License No: 890-ME SITE DETAILS Office Use Only Residential X Indoor Basement Service Only Commerical Outdoor X 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures HID Fixtures Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel NC Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Fluorescent Fixture Pumps Transformer Appliances Dryer Recpt Emergency Fixtures Time Clocks Disconnect Switches Twist Lock Exit Fixtures TVSS Other Equipment: 8.670 kw Roof Mounted Photovoltaic System to Include, 34-TSM 225 PA05 Panels, 34-Enphase M215 Micro Inverters,60A Disconnect,Combiner Box Notes' va="----- Inspector Signature: Date: October 20, 2015 Electrical 81 Compliance Form.xls _ /A 11��o��OF Opjyo� , cf.„ * * TOWN OF SOUTHOLD BUILDING DEPT. 765-1602 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) .11;$ ELECTRICAL (FINAL) REMARKS: DATE �tJ�t INSPECTOR Tc Tom Petersen Architects • Planners Construction Official: August 21,2015 Building Department for project at: 2290 Harbor Lane Cutchogue,NY 11935 !J(� Re: Solar Panel Installation—As-built Certification,Permit#39779 Pfaff Residence OCT 4 2015 2290 Harbor Lane Cutchogue,NY 11935rBLDG DEPT Cr 501 lNfilD Dear Sirs, I've reviewed the as-built solar panel installation at this location to evaluate the existing roof structure and the connection of the panels to the roof. Criteria: Applicable codes: 2010 Residential Code of New York 2001 Wood Frame Construction Manual Design roof load: 30 psf live load, 15 psf dead load,45 psf total load Design wind load: 120 mph, 35 psf;Exposure Category`B' My fmdings are as follows. 1. The new solar panels will imply an additional dead load of 3 psf. The existing roof structure (2x10 lower and 2x4 upper roof rafters @ 16"o.c.,with double 2x10 ridge, span=+/- 12'-9" and 16'-8")is sufficient to bear this additional load. This analysis is based on the existing single layer of asphalt shingles but is also adequate for two layers. • 2. The solar panels are attached to the roof with the SolarMount-1 rack system by UNIRAC. The rack system,roof connections and connection spacing are rated for 110 mph. This project requires the larger Solar Mount I-2.5 beam(2.5"high)and spacing of flange foot connection to roof at 48"o.c.maximum.Flange footing connections to the rail are not required to be staggered. The flange foot connections to the roof are 5/16"diameter x 4"long lag bolts. The total panel installation is no higher than 6"above the existing roof plane. It is a violation ofNYSED 7209 for any person, unless acting under the direction of a licensed professional, to alter an item in any way. If an item bearing the seal of a licensed professional is altered, the altering licensed professional must attach the notation `altered by'with his seal, signature, date of alteration, and description of the alteration. I therefore certify that the actual installation complies with the applicable codes and design loads mentioned above,as well as ASCE 7-05 and 2011 NEC(including Article 690), and is acceptable for approval. Please let me know if you have any questions on this information. Thanks! A � Rc, S' cerely yours, J P$F•PE) . °,� O� 1 * Tom Petersen "• I -14 „A"��% 0352 g0 Cc: Kelcy Pegler,Roof Diagnostics f_0NMF N���.' 6 Country Lane•Howell,New Jersey 07731•Telephone 732-730-1763,Fax 732-730-1783 • FIELD INSPECTION REPORT PORP DAA COIvIl1ArTS ro 'OtRW 'XON(1ST) l FOUNDA.TION(2ND) CCIc 9\-) O • / CJ H ROUGH FRNO& H PLUMBING - - • • R'..t11 . . . . $ INSULATION PER N,Y. STATE ENERGY CODE . . . . ' 1 • , y 3, C . . _, . FINAL . , . / . • MIMI • .le1 6C,Let th 11111 41� C ! G ci>6,7w b' .. . t,-t.....) . • ...'....,2 . ...,# v i . .. .. . a .. S J 6" Z TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD,NY 11971 4 sets of Building Plans TEL: (631) 765-1802 Planning Board approval FAX: (631) 765-9502Surve Y SoutholdTown.NorthFork.net PERMIT NO. (../..7---WCheck Septic Form - N.Y.S.D.E.C. Trustees Flood Permit Examined ,20 Storm-Water Assessment Form / 7r---- Contact: Approved ,20 Mail to: Disapproved a/c Phone: Expiration I//` ,, ,20 /,.1 w ldin: Insp tor • [-ic F rn E C1 E APPLICATION FOR BUILDING PERMIT i i 2015 Date 5'(� ' ,20 MAY INSTRUCTIONS his-a -: • u be c mpletely filled in by typewriter or in ink and submitted to the Building Inspector with 4 set of plans, c r�aie4 p jpian to scale Fee according to schedule. —13:4 ot-pl owing ocation of lot and of buildings on premises,relationship to adjoining premises or public streets or areas,and waterways. c.The work covered by this application may not be commenced before issuance of Building Permit. d.Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f.Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date.If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize, in writing,the extension of the permit for an addition six months.Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York,and other applicable Laws, Ordinances or Regulations,for the construction of buildings,additions,or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws,ordinances,building code,housing code,and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. (Signature of applicant or name,if a corporation) 0 WYL%VP. *PLACE QBE (06 ' et -i..A *J.1 Wit lo (Mailing address of applicant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician,plumber or builder Name of owner of premises Z fte131: p F (As on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer (Name and title of corporate officer) Builders License No. 53Lt — A Plumbers License No. Electricians License No. Q® - Other Trade's License No. 1. Location of land on which proposed work will be done: 22q0 HAMM. LAK € C'urcvi0€ House Number Street Hamlet County Tax Map No. 1000 Section I03 Block Lot 2 Subdivision Filed Map No. Lot 2. State existing use and occupancy of premises and 'ntended use and occupancy of proposed construction: a. Existing use and occupancy S► % N t1 jly fsjokfn C� b. Intended use and occupancy`Sky� �- Iflt vest a��(( 3. Nature of work(check which applicable):New Building Addition Alteration Repair Removal Demolition Other Work Moorkq ®i1`i�. (Description) 4. Estimated Cost ji B G Std•4{ r) Fee (To be paid on filing this application) 5. If dwelling, number of dwelling units Number of dwelling units on each floor If garage, number of cars 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of existing structures, if any:Front Rear Depth Height Number of Stories Dimensions of same structure with alterations or additions: Front Rear Depth Height Number of Stories 8. Dimensions of entire new construction: Front Rear Depth Height Number of Stories 9. Size of lot: Front Rear Depth 10. Date of Purchase Name of Former Owner 11. Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law, ordinance or regulation?YES NO 13. Will lot be re-graded?YES NO Will excess fill be removed from premises?YES NO v� 2A0 &Its • $ ione 14.Names of Owner ofpremises6 AFF Address . No.WI®2q 8°125 1 Name of Architect-IIfer4E•te230�� Address Zrmwoit-u 4'4;74 to f Phone No737.4/0 .1746 Name of Contractor paq calm QA LAI?,Address rfo to rt$fsl2INACf hone No.CoOd•a-Pt io•SS2S e too 201 15 a. Is this property within 100 feet of a tidal wetland or a freshhwaterw�et a d?A*YES NO L— * IF YES, SOUTHOLD TOWN TRUSTEES &D.E.C.PERMITS MAY BE D., b. Is this property within 300 feet of a tidal wetland? * YES NO * IF YES,D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey,to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10,feet or below, must provide topographical data on survey. 18. Are there any covenants and restrictions with respect to this property? * YES NO * IF YES, PROVIDE A COPY. STATE OF NEW YORK) SS: COUNTY OF WC -- e eN being duly sworn,deposes and says that(s)he is the applicant Name of individual signing contract)g con tact)above named, (S)He is the gotAllab OA tetleherrelar (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief;and that the work will be performed in the manner set forth in the application filed therewith. Swo_rr�,to before me this N day of 20 (s —1- �'i►ice .� ;._TAR&R„T '. .�«...>» .,_. Notary Public o ry • IOtTEti29 6&1�b10ik Si_. -ire of Applicant Notaryr NO. OdifiBlud inrSUffolk(County Ily ion)ExplrecNovtp,2017 ' , imilgtAtx e T1; ' A. Scott A. Russell .��` ° k f`= STORMWATER SUPERVISOR g- - MANAGEMENT a � SOUTHOLD TOWN-HALL-P.O.Box 1179 - 41.? Town of Southold 53095 Main Road-SOUTHOLD,NEW YORK 11971 ;` : �•rtrrlr�iit. CHAPTER 236 - STORMWATER MANAGEMENT WORK SHEET (TO BE COMPLETED BY THE APPLICANT ) DOES THIS PROJECT INVOLVE ANY OF THE FOLLOWING: Yes No (CHECK ALL THAT APPLY) ❑ ►' A. Clearing, grubbing, grading or stripping of land which affects more- than '5,000 square feet of ground surface. ❑ '4 B. Excavation or filling involving more than 200 cubic yards of material' within any parcel or any contiguous area. -C. Site preparation on slopes which exceed 10 feet vertical rise to 100 feet of horizontal-distance. ❑ Vii! b. Site preparation within 100 feet of wetlands, beach, bluff or coastal _ erosion hazard area. ❑ ! E. Site preparation within the one-hundred-year floodplain as depicted on FIRM -Map of any watercourse. ❑':! F. Installation of new or resurfaced impervious surfaces of 1,000 square feet or more, unless prior approval of a-Storrnwater Management Control Plan was received by the Town and'the proposal includes in-kind replacement of impervious surfaces. * If you answered NO to all of the questions above, STOP! Complete the Applicant section below with your Name, Signature, Contact Information,-Date & County'Tax Map Number! Chapter 236 does not apply to your project. * If you answered YES to one-or more of the above, please submit Two copies of a Stormwater Management Control Plan and a completed Check List Form to the Building'Department with your Building Permit Application. APPLICANT- (Property Owner,Design Professional,Agent,Contractor,Other) S.C.T.M. #:, 1000 Date. District /�j►i NAME �• &: �a1 � � !O � � 2g ✓ Section Block Lot �'JJ r- "">OR 13U1 R e DEP= : NMENT,USE ONLY***`- Contact information -f '(1- 3525 ronoor aumi - Reviewed By: MP - Date: Property Address/Location of Construction Work: 22q 8 HkE802.--LAi/d- - Fr Approved for processing Building Permit. t/ Stormwater Management Control Plan Not Required. ( U GHO (76- `'r'- 1' 5 - Stoimwater Managemeiit Control Plan is Required. ` (Forward to Engineering Department for Review.) FORM # SMCP-TOS MAY''2014 " - ' ' ' " ' ' • - ' - S }'f,��O� llr�jy� Town Hall Annex * *; Telephone(631)765-1802 {631)76 �5Q2, • 54375 Main Road CP • �` roger.richert "own.SOuUUU1IO a.nv.us P.O.Box 1179 Q Southold,NY 11971-0959 QCO �A��'I • BUILDING DEPARTMENT TOWN OF SOUTHOLD APPLICATION FOR ELECTRICAL INSPECTION • REQUESTED BY: I:Titv.s^j_ tstMA� ( Cj f-'Once s/ ate: c5 3-- ID Company Name: i.�Np l Name: �bS ` �"M'&A-NiC3 License No.: gqa - • NlE :: o.: 6-01-cfr .. JOBSITE INFORMATION: (*Indicates required information) *Name: --Ser-s--€7 E709 .Thc .a tk.. r *Address: 22 HAV.-race... 1.-AA/•) - C rrc4 al3-E- (la2, *Cross Street: *Phone No.: , rD3[• $', 72 Permit No.: 3 ??9 Tax.Map District: 1000 Section: 10 3 - Block: ( Lot: 2 *BRIEF DESCRIPTION OF WORK(Please Print Clearly) jti/S'T,c�LG AT rO /V of Tool.; Movrvl—ev SoCSF cm.r, (Please Circle All That Apply) *Is job readyfor inspection:p YE NO Rough In Final *Do-you need a Temp Certificate: YES'NO Temp Information(If needed) • • `Service Size: 1 Phase 3Phase 100 150 200 300 350 400 Other *New Service: Re-connect Underground Number of Meters Change of Service Overhead Additional Information: • PAYMENT DUE WITH APPLICATION PaS si73,6 .82-Request for Inspection Form 3 rii �Y .' , F 5, UThOL-, ,:* ":3*PERT�� RECORD CARD )60 ,0 - /o,,7 - l -- ,,,9,-, �'� • OWNER STREET -2_2_9 0 VILLAGE DIST. SUB. LOT . ' h Pe,P6*P ►— za w air e. CI v rc 1,ra o v e �-i e c� FORMER OWNER '� N E !IF"; J1 X. C. Whrf� Z-gdna GAJ/2/s .A a 0, /�i/.`�4... a--; 4:6.;,4a.,„ Z,? J o /�z �;E� SW TYPE OF BUILDING . � 1dAe i- C -4r& i =`I L L_ La .lCie-± Cbcy,-,41 -- - .. RES. /;4 SEAS. VL. 9 FARM COMM. CB. MICS. r Mkt. Value ' LAND IMP. TOTAL DATE. REMARKS <5746 `?/� // ,/g 1/7f fid//( )} idi//f4 f© ,e, e, Wile. ,.. .,F1/ 5,,, ,Ar ' 7 o D /O©O /7cu / 3/i/r alr u . >f 0 I . )-1400' 1 -i-n • / 0 14 04 6f-W 36:f82_ ` ii d//l. o c_o. j -•- DC) ;' 300 75'00 . r/34o6 &/36. 1) LP4 E�.5Sb'. Q1-rer -ion e . 7 0 o 7 500 8 as 0 I/17‘/&"°7 a . . -L- qqq- h l P 717, J°-ta ' $,-6-5'0 066 700 K3 0 D. 7000 ✓ 9/5 4/ zoo �511/ � r��i � G� �) AGE BUILDING CONDITION . NEW NORMAL 1 BELOW , ABOVE FARM Acre Value Per Value Acre / Tillable FRONTAGE ON WATER Woodland FRONTAGE ON ROAD Meadowland DEPTH House Plot BULKHEAD Total DOCK -.ids �"^r..i.�.. ^."ti',"'r n4„ `•,,- `7,-* ,ter,-`ins 1,t';'°1'!'.h. t `;;Y _ - ;:-'`b> -f. ti ., ^s ": ' >LOR Yel(ow 6-1(s22/1A,/W 1 ,1,{,. r .i-t,y --:5J------:,,,--„,:-,: TRIIVI MINI ■■■.1111 Nti -1 ' 1111111111111 IMII 111 ,, 1111111111111111 ■■■ ®■• ' 55., MINN ____MEM II I SSl!l,iinp, s •t iii_ i■mil ii___•1_ I ii At 31.5 % �m �. a ■.!■_M■ 3� Mill II Y - - ' . REM 11111 ■1 E© �■■■■ s �ERN■Ell ■I ■■■! ,..• � �: - ,f .. x � - Elm _ ■_I■�■■■■ —_ it MINEla EINE 1 MI MEM II {' w •s r.. 103:1-28 1/06 __.. - -M■■■■■ a =1'01R.' El MEM M. Bldg?'l� ■■■■■■ 0021, ■I!11111.1111.1111 II 6"kis/.�a► 16 930 7 ' a - NNE! I■ - ■■■■ Extension ■■■■■■ RV- 1111_— ■ ■■ ■ 5 3x// = 33 3.s 0 // c ■ ■■■■■ ■ !■■■■ Extension -■ mn ■- • ■■-■ ar' O': Ell111111■■ ■■■1=! Extension Foundation f C. Bath cl/ii 7 3..5 I Dinette Porch (tea k C� / Basement l/f Floors I< = ! Q a �� lit t (7,:it-rt t e-)0 ( 1 Porch Ext. Walls V f Interior Finish S/,12, LR. / Breezeway Fire Place Heat g, j j' ;/ Ties DR. ,arage lr -a3xa = SS a ,3:p - R-0, 0 Type Roof Rooms 1st Floor BR. _Rae,/,1 A ( ) 5ptt @o7.0 Recreation Room l'e- Rooms 2nd Floor FIN.•B 0. B. ��/ • // Dormer .3.6n#� Driveway � t 2,5 ,.Tota(s��40 f n� taa b l5/06 vi 5Wta' .''a.6041,Cray° 1—Q--..ii 6 `144-Zr` v 6t- , . $ . -FF roo — 5 -.' , a5):: Iia _ 16'�T, � c. 5J _.r - meet 11,\ tkoz..e.) No— U aw 10e _H � S• S 6'3/6 q/iFishp� ../ - „ ,aam nrg. Bohemia.NY 11716 170 Wilbur Place.Suite 100,B "� I-Iome 1-800-75-SOLAR SOLAR May 8, 2015 Solar Panel Installation Pfaff Residence 2290 Harbor Lane Cutchogue, NY 11935 Dear Sir/Madam: Please find the following attached documents for the Pfaff Solar Photovoltaic Installation at 2290 Harbor Lane in Cutchogue, NY: • Check made payable to the Town of Southold for the fee of$200 • Two (2) original Southold Building Permit Applications - • Application for Certificate of Occupancy • Application for Electrical Inspection • Stormwater Management Worksheet • Four (4) Sets of stamped and sealed architectural plans with spec sheets • Roof Diagnostics Solar's Insurance Information,including Workers Comp, Disability, &Liability documents. • Copy of ME License Please do not hesitate to contact me with any questions or concerns. I can be reached at 631-416-5525. Sincerel Jaime Coltman Permitting Specialist • NRGHomeSolar.com STATE OF NEW YORK WORKERS' COMPENSATION BOARD CERTIFICATE OF NYS WORKERS' COMPENSATION INSURANCE COVERAGE la. Legal Name&Address of Insured(Use street address lb. Business Telephone Number of Insured only) 800-757-6527 Roof Diagnostics Solar&Electric of NY 1 c. NYS Unemployment Insurance Employer Registration 614 Corporate Way,St 4 Number of Insured Valley Cottage,NY 10989 50-39533-4 1d. Federal Employer Identification Number of Insured or Work Location of Insured (Only required if coverage is Social Security Number specifically limited to certain locations in New York State, 454175170 i.e.,a Wrap-Up Policy) 2. Name and Address of the Entity Requesting Proof of 3a. Name of Insurance Carrier • Coverage(Entity Being Listed as the Certificate Holder) Federal Insurance Company Town of Southold Building Department 3b. Policy Number of entity listed in box"la" Town Hall Annex Building 54375 004 4727794 00 Route 25 3c. Policy effective period PO Box 1179 Southold NY 11971 07/01/2014 to 07/01/2015 3d. The Proprietor,Partners or Executive Officers are X included(Only check box if all partners/officers included) ❑ all excluded or certain partners/officers excluded This certifies that the insurance carrier indicated above in box "3" insures the business referenced above in box "la" for workers' compensation under the New York State Workers' Compensation Law. (To use this form,New York (NY) must be listed under Item 3A on the INFORMATION PAGE of the workers' compensation insurance policy.) The Insurance Carrier or its licensed agent will send this Certificate of Insurance to the,entity listed above as the certificate holder in box"2". The Insurance Carrier will also notify the above certificate holder within 10 days IF a policy is canceled due to nonpayment of premiums or within 30 days IF there are reasons than nonpayment of premiums that cancel the policy or eliminate the insured from the coverage indicated on this Certificate. (These notices may be sent by regular mail.) Otherwise, this Certificate is valid for one year after this form is approved by the insurance carrier or its licensed agent, or until the policy expiration date listed in box"3c",whichever is earlier Please Note: Upon the cancellation of the workers' compensation policy indicated on this form,if the business continues to be named on a permit, license, or contract issued by a certificate holder, the business must provide that certificate holder with a new Certificate of Workers' Compensation Coverage or other authorized proof that the business is complying with the mandatory coverage requirements of the New York State Workers' Compensation Law. Under penalty of perjury, I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has the coverage as depicted on this form. Approved by: Ronald B.Giadrosich,McGriff, Seibels&Williams Inc.(Executive Vice President) (Print name of authorized representative or licensed agent of insurance carrier) g"'40: "A2-- ..-e—__ 12/5/14 Approved by: (Signature) (Date) Telephone Number of authorized representative or licensed agent of insurance carrier: (205)581-9415 Please Note: Only insurance carriers and their licensed agents are authorized to issue Form C-105.2 Insurance brokers are NOT authorized to issue it. C-105 2(9-07) tq-10/c20 1 STATE OF NEW YORK WORKERS'COMPENSATION BOARD CERTIFICATE OF INSURANCE COVERAGE UNDER THE NYS DISABILITY BENEFITS LAW PART 1. To be completed by Disability Benefits Carrier or Licensed Insurance Agent of that Carrier I a. Legal Name and Address of Insured(Use street address only) lb.Business Telephone Number of Insured ROOF DIAGNOSTICS SOLAR AND (800) 757-6527 ELECTRIC OF NY LLC lc.NYS Unemployment Insurance Employer Registration dba NRG HOME SOLAR Number ofInsured 614 CORPORATE WAY VALLEY COTTAGE, NY 10989 Id.Federal Employer Identification Ntttnber of Insured or Social Security Number 454-17-5140 2. Name and Address of the Entity Requesting Proof of 3a.Name of Insurance Carrier Coverage(Entity Being Listed as the Certificate Holder) NEW YORK STATE INSURANCE FUND Town of Southold Building Department Building 54375 Route 25 3b.Policy Number of entity listed in box"la": P.O. Box 1179 DBL 6523 96 - 4 Southold, NY 11971 3c.Pole'effective period: 08/07/2014 to 08/07/2015 4.Policy covers: a.Dig All of the employer's employees eligible under the New York Disability Benefits Law b.[J Only the following class or classes of the employer's employees: Under penalty ofperjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has NYS Disability Benefits insurance coverage as described above. Date Signed 12/5/2014 By_ J oseph J M (SigratLre of irsuranoe m rner's authonzed represertati,ie of NYS Lice rsed irsurarce Agent of that insurance m,mer) Telephone Number (866) 697-4332 Title Director of Disability Benefits Insurance IMPORTANT: If bac"4a"is checked,and this form is signed by the insurance carrier's authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE, Mail it to the certificate bolder. If box-4b'is checked,this certificate is NOT COMPLETE for purposes of Section 220,Subd,Sof the Disability Benefits Law. It must be mailed for conviction to the Workers'Compensation Board,OS Plans Acceptance Unit,20 Park Street,Albany,Net:York 12207. PART 2.To be completed by NYS Workers'Compensation Board(Only if box"4b"of Part 1 has been checked) State Of New York Workers'Compensation Board According to information maintained by the NYS Workers'Compensation Board.the above-named employer has complied with the NYS Disability Benefits Law with respect to all of his/her employees. Date Signed —By (Signature of NYS Workers'Compensation Board Employee) Telephone Number Title Please Note:Only insurance carriers licensed to write NYS disability benefits insurance policies and NYS licensed insurance agents of those insurance carriers are authorized to issue Form DB-120.1. Insurance brokers are NOT authorized to issue this form. DB-120.1(5-06) Certificate Number 298903 • Acc•R o® CERTIFICATE OF LIABILITY INSURANCE DA1YYYY) 12/05/201 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT Danielle Butterfield AME MCGRIFF,SEIBELS&WILLIAMS,INC PHON PO Box 10265 PHONE Ext):800-476-2211 (NC,No) Birmingham,AL 35202 ADDRESS dbutterfield@mcgriff.com INSURER(S)AFFORDING COVERAGE NAIC# INSURER A-Scottsdale Insurance Company 41297 INSURED INSURER B:Liberty Mutual Fire Insurance Company 23035 Roof Diagnostic Solar Holdings,LLC Roof Diagnostics Solar&Electric of NY,LLC dba NRG Home Solar INSURER C:Federal Insurance Company 20281 614 Corporate Way Suite 4 Valley Cottage,NY 10989 INSURER D'Navigators Specialty Insurance Company 36056 INSURER E • INSURER F COVERAGES CERTIFICATE NUMBER:FNFxDPLK REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS INSR TYPE OF INSURANCE ADDL SUBR POLICY EFF POLICY EXP LTR INSR wVD POLICY NUMBER (MM/DD/YYYY) (MM/DD/YYYY) LIMITS A GENERAL LIABILITY 102590435C 08/04/2014 07/01/2015 EACH OCCURRENCE $ 2,000,000 DAMAGE TO RENTED 100,000 X COMMERCIAL GENERAL LIABILITY PREMISES(Ea occurrence) $ CLAIMS-MADE X OCCUR MED EXP(Any one person) $ excluded PERSONAL&ADV INJURY $ 2,000,000 GENERAL AGGREGATE $ 4,000,000 GEN'L AGGREGATE LIMIT APPLIES PER PRODUCTS-COMP/OP AGG $ 4,000,000 7 POLICY PE a Ti LOC $ B AUTOMOBILE LIABILITY, AS2Z91462454014 04/29/2014 04/29/2015 COMBINED SINGLE LIMIT 1,000,000 (Ea accident) $ X ANY AUTO BODILY INJURY(Per person) $ ALL OWNED SCHEDULED BODILY INJURY(Per accident) $ AUTOS AUTOS OPERTY X HIRED AUTOS X AUTOSWNED (Perraccdent)AMAGE Deductible Comp/Coll $1,000 D UMBRELLA LIAB X OCCUR ELU782570/01/2015 08/04/2014 07/01/2015 EACH OCCURRENCE $ 5,000,000 X EXCESS LIAB CLAIMS-MADE AGGREGATE $ 5,000,000 DED RETENTION$ $ C WORKERS COMPENSATION 00447277940000 07/01/2014 07/01/2015 X WC STATU- OTH- AND EMPLOYERS'LIABILITY Y/N TORY LIMITS ER ANY PROPRIETOR/PARTNER/EXECUTIVE E L EACH ACCIDENT $ 1,000,000 OFFICER/MEMBER EXCLUDED? N I A (Mandatory in NH) E L DISEASE-EA EMPLOYEE $ 1,000,000 If yes,describe under 1,000,000 DESCRIPTION OF OPERATIONS below E L DISEASE-POLICY LIMIT $ $ DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES (Attach ACORD 101•Additional Remarks Schedule,if more space is required) Certificate Holder is Additional Insured under General Liability as required by written contract. CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF,NOTICE WILL BE DELIVERED IN Town of Southold ACCORDANCE WITH THE POLICY PROVISIONS. Building Department, Town Hall Annex Building 54375 Route 25 AUTHORIZED REPRESENTATIVE P.O.Box 1179 � Southold,NY 11971 �• Page 1 of 1 ©1988-2010 ACORD CORPORATION. All rights reserved. ACORD 25(2010/05) The ACORD name and logo are registered marks of ACORD co o0 1 Q S m m,i 11} -a , • CA r , g xmCO cn ; ' n ‘X-ii-d-4—e-''s , , INSPEECLTEIC07.-ICEAOLLMRED ' BED d, PROJECT DESCRIPTION : DAT '4 nrg' 34 x 255W ROOF MOUNTED SOLAR PHOTOVOLTAIC MODULES Home TOTAL NUMBER OF 34 FEAeli- _!....2•7 **♦ PROJECT SITE TOTAL NUMBER PANELS Y BUIL RY��41*_-__ T NOTIFY DING DEPARTMENTAT r .,. .�., SOLAR Array Area `'{ : - . (Roof#1) 308 35 sq.ft 765 18t�2 8 AM TO 4 PM FOR ' rr ROOF SYSTE(Roof#2) 308 19 sq.ft TH E/\ FOLLOWING INSPECTIONS: \ t4 .. SO AR ANDELECTRIC,LLC SHEET INDEX ,, 5-,'."' PV-1 SITE PLAN & VICINITY MAP 1. FOUNDATION TWO RE I (REp \ ,°ae- ;r,"' `.'° . '- Peo ay PV-2 ROOF PLAN & PANELS ,_, '� ` _ ., -µ, , _ e oy PV-3 ROOF ATTACHMENT DETAILS FOR POURED CONC t! I \ ,A:12296 \ 6d` y�PgFTF9a F & ELECTRIC EQUIPMENT 2. ROUGH - FRAMIN " W 'Hir 9r-`_P13` `s„''' z° PV-4 ELECTRIC LINE DIAGRAM $. INSULATION & P �IPBING t' PV-5 LABELING \ ^ PV 6 SPECIFICATION DETAILS 4. FINAL - 'e ,. ague' 5_ 'di t\. "s?...,,,.to D,6290 yo PV-7 SPECIFICATION DETAILS ACTION MUST \ "° yr PV-8 SPECIFICATION DETAILS BE ,i` 7 FOR C.O. pF \\ +4"`` " °`Y PV-9 SPECIFICATION DETAILS A INS �y i,,. ^ PV-10 SPECIFICATION DETAILS I ION SHALL ` f;c c.r •y Ta.i s;, V` PV-1 1 SPECIFICATION DETAILS "A le . OF THE CO DEET THE \\ , E _ P ,, • !'K STAT � �Y DES OF NEW \ 47 , :,,,. °. 0 /' RESPONSIBLE FOR 'r ' ' DESIyGN\ �y STRUCTION ERRO'• ` T / 61111111,0 0 EZ L ,,o(3* 2 I VICINITY MAP o Oill' O \ Py-' ❑ O� a \ **1:**, a\aPGe ETAIN STORM WATER RUNOFF \ Gee PURSUANT T • 'i• ECT SITEE. �, ayilli \ 0 CHAPTER o N : '.t :3,74; :41,''-'11%.".-1:44‘:. a: ®**It �a ® OF THE TOWN COD 11 *Wilik3N 3 S3 PI re 1 S u � pr PSE ,,,a4 #04 ® :o O r 3 e #4 \ ,:::;;It ~ .-,,,.0.4NIA,, 1 CEP �' E ` <.!! HA o �� .a te 3CCAWN 46T6° � ®kiS I-- � '� co % ,ES 2�6 Harb > Irr�' C x C \\�J Eoue�Eu i _ r�S of w F ® .BARD y i ` SO -, I I �P,. �, •. '-'4'‘,,,:.-�, DrewmB No Dm+MB By SiSTEES , ' €4{ Dia ZB APR 3016 \ /` �' SOLAR GAD 1 SITE PLAN WITH ROOF PLAN \ / SITE PLAN & 3 HOUSE PHOTO ��. VICINITY MAP a/5/,e -1 i Y ARRAY& ROOF AREA CALC'S111' *7 ROOF#1 ARRAY AREA = 308.35 SF Home ROOF FACE AREA = 1370.83 SF SOLAR 308.35/1370.83 = 23% OF ROOF FACE AREA COVERED BY ARRAY ROOF ROOF#2 DIAGNOSTICS ARRAY AREA = 308.19 SF SOLAR AND ELECTRIC,LLC ROOF FACE AREA = 424.81 SFaowE 9s��F 308.19/424.81 = 73% OF ROOF a� FACE AREA COVERED BY ARRAY -';7-' \ • *~';;,•f. I:S 0, 2. r 10 s' \�, T9. 436290+02 4111ROOF DESCRIPTION .�\\\\\\\\\ �,\\, COMPOSITE ASPHALT SHINGLES \ \ \\ Alt\\ (R1) . 34' `,\\ ...,0```'\\,\\`,\` \\\` AZIMUTH (R1) . 248' - \�bQ \ \ t SHADING . 86% , , ,\\`\ \\\\ \`\\ ', o PITCH (R2) . 34' ,``\\\\, ` \\ \\\\\` Eyp0 ❑ „% AZIMUTH (R2) 158' ro ,\\\ \x \ o a i rn SHADING • 92% 6- �� b`r \\` I s s. n `, �� L� c\eaiaacle 2'-.77. I / \s. w A u'z FjEItV A d.o `1i awl =I, ° N LEGENDi r `. .tl}` �,� �,, s, CO • a ENPHASE MICROINVERTERS Pp,.0*:0- \� ayo�aacas �� -4- u'"� M-215-60-2LL-S22-IG pP<Cpg pgp�\� \� �� r a� .'� -, 0 ROOF ATTACHMENT a��0 5p�01 \\ 1% ,', ,\ •. s, ---- RAFTERS �„AAP Poi.\” % ��,'• ''4 %,• � .� ---- CONDUIT 36:1N79-40Y-e) �a�2G eQ� ��''\ \ �'' O� L O ELECTRICAL EQUIPMENT �0\G?v2 Cpl O\.0 /��' \ '� $ \,2\.&-:02'.'• �aP L1`'b t�G'�.E ot' Gp� ,,V 101N ' MODULE SPEC'S '. `a� G„,01." 1y"` J\.p 0G„, 1. Drawing No - Drawing BY A JrA 3—3 c.,1\90:."- ••'\' ' 5., Y PB APR P616 I I `1`V IJ` SOLAR CAD 71) I In TSM-255PA05 08 ROOF PLAN & PANELS tROOF PLAN & f PANELS PANELS-255W TRINA SOLAR PANELS - A; PV-2 nrg UNIRAC SOLARMOUNT Home .�. RAIL WITH L-FOOT 1 G GREEN FASTEN FLASHING. \- PV MODULE SOLAR ECO-GFI-BLK-812 WITH ROOF ECO-CP-SQ COMPRESSION DIAGNOSTICS BRACKET IIIIIIIIIIIIIIIIi4SOLAR AND ELECTRIC,LLC .I --4 2 5"MINIMUM PENETRATION SEALED MODULE CLAMP& my�es"'Fq�aF,, WITH APPROVED SEALANT COMPOSITE ASPHALT m ts.,rxo =2-, SHINGLES *P _W,II r •3.,..6.03:21;44 OO,OP " 1 ATTACHMFNT DETAIL -a,-2 \� n t W o m re a = u>- W y NpN U K W 0Too w (E)TO MAIN SERVICE PANEL Q (INTERIOR WALL) a- IiJ FROM PV ARRAY O- cc (E)UTILITY METER w (EXTERIOR WALL) 0Z = (N)UTILITY AC DISCONNECT 0 c0 _ —� (EXTERIOR WALL) I 0 0 - -- 1 . . (N)L•GATE 120 CD F-- �� PRODUCTION METER o -- (EXTERIOR WALL) r (N)100AMP PV LOAD CENTER N 00 I I (EXTERIOR WALL) CD _ „ _—� (N)JUNCTION BOX FOR ENVOY c- 4FROM UTILITY PROVIDER e-I _ I (OVERHEAD) Drawing No ® I awing By T— DrII Rev By I I—i — — I Date 28 APR 2015 I „ I _ JJ' SOLAR CAD _ t• - E GRADE LEVEL I , e. ROOF &ELECTRIC EQUIPMENT ROOF ATTACHMENT DETAILS " 2 ELECTRICAL ELEVATION DETAIL ,/ - a PV-3 I • 1R` r�� (E)Utility Meter (E)MAIN SERVICE PANEL 60A FUSED AC 60A FUSED AC L-GATE 120 PV 100A SOLAR ONLY ((�, • 200A RATED BUS BAR DISCONNECT 40AAMP DISCONNECT WITH PRODUCTION LOAD CENTER Home MP n FUSES n 40A FUSES n METER �+ JUNCTION BOX SOLAR o°o Y D Y DN. Y B =J 20A/2P A BRANCH#1 __ ..7V 4..A °o° •J• lJ�� •�• 11 !\•�. ll�� o°°°° �S • AC- — —• ROOF o I N 21 DIAGNOSTICS ---- ®i ----�.--- ----b.--_ --_,��A�J r v_ ,I $ 1,1� I SOLAR AND ELECTRIC,LLC (E) 200A I I I L J EGC aE°Aac Utility •To MAIN 1 z— I I MODULES WITH y�oP PerF6:sx I - GROUNDING WEEBS 6°°� ' .93.‘t", SOLAR ARRAY(8.67kw) r v VLi J I AND ENPHASE ¢ "� m `,t�: • ,_ N BRANCH#1 °z M-215-60-2LL-S22-IG * `dy yo 17 MODULES IN PARALLEL CONNECTED BRANCH CIRCUIT 0 JUNt(TION BOX N� 4EGC/GEC 17 MODULES TRINA SOLAR TSM-255PA05 08 ON ROOF#1 0 y I ?). o3629 r-',.., �' J BRANCH OPERATING CURRENT=19 125A 20A/2F A I BRANCH#2 of ae t ACA —1 • I • o (E)Loads A BRANCH#2 --• • I • AO ,f-r.., 17 MODULES IN PARALLEL CONNECTED BRANCH CIRCUIT I • N 1 --•/- 0— - 17 MODULES TRINA SOLAR TSM-255PA05 08 ON ROOF#2 v I. V------11 S 1 J L--- GEC BRANCH OPERATING CURRENT=19 125A EGC I / GROUNDING WEEBS MODULES WITH (E)GROUND ROD NOTES: 15__P AND ENPHASE —1- 1. ALL MODULES WILL BE GROUNDED IN ACCORDANCE —• • MONITORING M-215-60-2LL-S22-IG — WITH CODE AND THE MANUFACTURER'S INSTALLATION INSTRUCTIONS • . OUTLET 1 2 ALL PV EQUIPMENT SHALL LISTED BY A RECOGNIZED TESTING LAB V o 3 NOTIFY SERVING UTILITY BEFORE ACTIVATION OF PV SYSTEM ui C w 4 WHEN A BACKFED BREAKER IS THE METHOD OF UTILITY CI o INTERCONNECTION,BREAKER SHALL NOT READ LINE AND LOAD g rn g Pr 120%RULE 5 WHEN A BACKFED BREAKER IS THE METHOD OF UTILITY INTERCONNECTION, a m f,'- BURSAR RATING 200 �- THE BREAKER SHALL BE INSTALLED AT THE OPPOSITE END OF THE OF. d =5 MAIN BREAKER RATING 200 WEATHER STATION 1200x12)-200A-40A INFORMATION BUS BAR OF THE MAIN BREAKER PROPOSED MW BACKFE ED 40A ISLIP LONG ISL 6 WORK CLEARANCES AROUND ELECTRICAL EQUIPMENT WILL BESYSTEM i MACARTHUR AP MAINTAINED PER NEC 110 26(A)(1),110 26(A)(2)&110 269A)(3) - 7 ALL EXTERIOR CONDUITS,FITTINGS AND BOXES SHALL BE RAIN TIGHT - CO ASHRAE 2%AVG 31°C AND APPROVED FOR USED IN WET LOCATIONS PER NEC 314 15 - I7_ 13-90 MM ABOVE 8 ALL METALLIC RACEWAYS AND EQUIPMENTS SHALL BE BONDED AND C INVERTER SPECS • ROOF SURFACE ELECTRICALLY CONTINUES MODULES SPECS ` TEMP 53°C rWIRE GAUGE #6 WIRE OCP:53.25A 1 INVERTER TYPE'ENPHASE M215-60-2LL-S22-IG QTY:34 SERVICE INFO TEMP RATING 75°C AMP RATING x TEMP DE-RATE QTY•34 MODULES TYPE TSM-255PA05 08 AMP RATING :65A MAX AC TO BE LESS OR EQUAL TO WATTAGE 190-270W UTILITY COMPANY.-- WIRE OCP FOR WIRE TO BE WATTAGE 255WTEMP DE-RATE:0.94 APPROVED BY 2011 NEC SERVICE VOLTAGE:240V NOCT WATTAGE:184W MAIN SERVICE VOLTAGE'240V , J CEC EFFICIENCY'96.5% FRAME THICKNESS.35MM MAIN PANEL BRAND - Q ® O i O W FRAME COLOR.BLACK MAIN SERVICE PANEL 200A 1#6AWG NGAGE CABLE& 3-#10 THN-2 Voc'37 70 MAIN CIRCUIT BREAKER RATING 200A BARE COPPER 1-#6 THWN-2 EGC/GEC 3-#12 THWN-2 3-#8 THWN-2 3-#6 THWN-2V max 305 MAIN SERVICE LOCATION:SOUTH WALLND IN FREE AIR IN 1"EMT CONDUIT W 1-#12 THN-2 EGC 1-#6 THWWN-2 EGC/GEC 1-#6 THN-2 EGC/GEC P Isc 8 92A SERVICE FEED TYPE:UNDERGROUND VOC 24OVAC • VOC 240VAC VOC 24OVAC VOC 24OVAC IMP 836A MAINSERVICEPANELGROUND:EXISTINGGROUNDRODLSC:15 30AAC DISC 15 3OAAC DISC:30 60AAC - SSC 30 6OAAC } Drawing No Drawing By I A 2-JUNCTION BOX ENPHASE INVERTER BRANCH CALC"S,JUNCTION BOX TO LOAD CENTER CALC"S, ENPHASE INVERTER TOTAL SYSTEM CALC"S , Rey By Date 28 APR 201E I g 1 1-L-GATE 120 PRODUCTION METER QTY:17 MAX AC:19.125A QTY 17 - MAX AC. 19.125A QTY 34 MAX AC:38.25A SOLAR CAD 1-100A SOLAR ONLY LOAD CENTER NOC:0.9- (QTYx NOC)x125% NOC:09 (QTYx NOC)x125% NOC:09 (QTYx NOG)x 125% 1 Ci I 2-20A/2P SOLAR BREAKER 1-15A/1P ENVOY BREAKER WIRE GAUGE :#12 WIRE OCP:23.50A WIRE GAUGE •#10 WIRE OCP 23 45A WIRE GAUGE :#8 WIRE OCP:47.00A TEMP RATING '75°C AMP RATING TEMP DE-RATE TEMP RATING :75°C AMP RATING x TEMP DE-RATE TEMP RATING .75°C AMP RATING TEMP DE-RATE 2-6OAFUSED ACDISCONNECT WITH MAX AC TO BE LESS OR EQUAL TO AMP RATING •35A MAX AC TO BE LESS OR EQUAL TO AMP RATING 50A MAX AC TO BE LESS OR EQUAL TO ELECTRICAL IDI AMP RATING :25A LINE DIAGRAM 40A FUSES WIRE OCP FOR WIRE TO BE WIRE OCP FOR WIRE TO BE WIRE OCP FOR WIRE TO BE IMP 1-40A/2P SOLAR BREAKER 1 TEMP DE-RATE.0 94I APPROVED By 2011 NEC TEMP DE-RATE 0 94 APPROVED BY 2011 NEC J TEMP DE-RATE:0.94 - APPROVED BY 2011 NEC J „yy„ PV-4 V � l nrg. DISCONNECTION MEANS; TO BE INSTALLED AT AC OPPERATING VOLTS . 240V ALL AC DISCONNECTS PER NEC 2008 690.14(C)(2) AC OPPERATING CURRENT : 38.25 AMPS Home SOLAR SOLAR AC DISCONNECT TO BE INSTALLED ON THE FACE OF THE ROOFSERVICE METER PANEL PER NEC 2008 DIAGNOSTICSSOLAR AND ELECTRIC,LLC 705.10 DISCONNECTING MEANS MAY BE ENERGIZED ypEO Aq0 IN THE OPEN POSITION;TO BE INSTALLED y�Pg F.RfT", Marking Content And Format o 4:0 AT DISCONNECTING MEANS PER NEC 2008Marking is required on all interior and exterior pv conduit, ¢�"" �:=* 690.17 * ASV raceways, enclosures, cable assemblies, and junction boxes to ,R -,.�- r WARNING alert the fire service to avoid cutting them. marking shall be '' 4.0FN9,s4°� ELECTRIC SHOCK HAZARD placed every 10 feet, ,at turns and above and/or below DO NOT TOUCH TERMINALS. penetrations, and at all pv combiner and junction boxes. TERMINALS ON BOTH THE LINE AND LOAD SIDE MAY BE ENERGIZED Reflective weather resistant material suitable for the IN THE OPEN POSION.IT environment (durable adhesive material must meet this INVERTER OUTPUT CONNECTION; requirement) TO BE INSTALLED TL AT MAIN SERVICE PANEL Marking Content and Format N 2 PER NEC 2008 690.64 (B)(7) • Marking Content: caution: solar circuit ffi ces J d WARNING F F2 • Red Background '6 _'i INVERTER OUTPUT CONNECTION • White lettering Minimum 3/8"letter height 3 ° " DO NOT RELOCATE • All Capital Letters THIS OVER CURRENT DEVICE • Arial or similar font, non—bold a • Reflective weather Resistant material suitable for MARKING SHOULD BE PLACED ON the enviornment '(durable adhesive material must ALL INTERIOR AND EXTERIOR PVmeet this requirement) CONDUIT, RACEWAYS, ENCLOSURES, AND CABLE ASSEMBLIES, EVERY 10 FEET, AT TURNS AND ABOVE AND/OR BELOW PENETRATIONS AND ALL PV COMBINER AND JUNCTION BOXES CAUTION: SOLAR CIRCUIT Drawing Na Drawing By Rev By TO BE LOCATED AT MAIN Date 29APR 2O15 SERVICE PANEL: SOLAR Can CAUTION: 7 SOLAR ELECTRIC SYSTEM CONNECTEDf I / ' .I j LABELING Y ow. IN-5 r , nrg. - Home • EnphaseM215 Mrcmmverter!/DATA SOLAR .Enphase'Microinverters INPUT DATA(DC) M215-60-2LL-S22-IG/623-IG/524-10 ROOF +(`�� - r Recommended inputpower(STC)' rv, - _ `iso;2zaw . -- _ _ -G_. - _ A-__ DIAGNOSTICS En p Kase° 1 Maximum input DC vo@age ' 46,V .. _ -. sous AND ELECTRIC.LLC 'Peak power tracking voltage,: - 27 V=39,V �Rgo aRc Operating range 16V-48V `Q4 ae F PETE.yi!• Min/Max start voltage - 22 V148V - } a o`° 9`rmo Max DC ahorccircutt current - - 15 A ie 11` 2 Maxinputiurrent _. „ _ .. :10A . " ` ,~f`: * =- r OUTPUT DATA(AC) eaOa VAC X240 VAC ms's/. DI5290 yep L a -c, prt 1.,t-- i „i _ F O e'ts i } - -.,kt�, - -:}3• _ - Peak output power - _,.,,. _, -- 2225 W. - _ -.. 225 W' _.' „T., -- v u A Rated(contmuoun output power 215 W 215 W -, - _ t Nominal output current,•:_.: ., . 'r.'__ 11 A Gums at nominal duro_tion)'1,-„13,?A(ATMS at nomroot duraton)- .`' Nominal voltage/range 208 a/183-229V 240 V/211-264 V - - _ - .1 -Nominalfrequencyhargs'z - - ,•--7.600/57-61,Hz -,''..:=T.- _ s60.01576,1H2 _y ,_ Extended frequency range' - 57-62.5 Hz 57625 Hz 1.. :. f ,s^•;. . , ;_ a'a- .•,,._ _ +` :-a - Maximum units per 20 A branch circuit' 25(three Phase) - - 17(stogie phase) -_ ,•4' .` 5-;-„-'` ''--Y1 _'Maximum output fault current .- , ,, 850 mAnns for 6 cycles ,-„850 erA,rms for 6 cycles _. - L -`:"-,yr= , -,,,,,'_.h,_ _EfPICIENCY - __ ',-,;;;a - _ r - ° - -.- - -CzCweightedetilciency.240 VAO' - 06.5Yo: Fl • - 2 0 m �-"•`L-r r nT "x _ _•_ 'r- 'CEC weighted efficiency,208 VAC • 96 5% 3 xi 3�.._..f.:�.. .�....?-"e: _ - '- `_ _ _ _ p0 off o .2 Peak lrivetler efficiency i, _ _ t 955%: ' - a .0 o - Static MPPTefficierry(weighted reference EN5O530) 994% w o 9 Z _...... ____ _ ,....___ _ __ . . ..__.-,_: _- >-.-___.__.- .____ _..... . _...__,_. ,Nlghttimepowerconsunipton . _ _ '65 MIN' "'_ - .,.. - - 'O m U The Enphase'M2i5 Microinverter with integrated ground delivers increased energy harvest and MECHANICAL DATA a reduces design and installation complexity with its all-AC approach-With the advanced M215,the DC '',?tmbient temperature range•,,. '"_ 40,1Cta+65°C-•-;,_ - _ - .r.,,-' „ w circuit is isolated and insulated from ground,so no Ground Electrode Conductor(GEC)is required Dimensions(WxHxD) 163 mm x 173 mm x 25 mm(without mounting bracket) 0_ weight's:e T, a, _•,: _ u 1 ..`•' I6k9(3:4ibs) ,�'.�_,, - r_,._ - for the microinverter.This further simplifies installation,enhances safely,and saves on labor and materials costs. Cooing Natural convection-No for Enclosure environmenlat rating• ` _ ,• ,., Outdoor-NEMA36- - - ' The Enphase M215 integrates seamlessly with the Engage`Cable,the Envoy"Communications FEATURES Gateway'',and Enlighten,Enphase's monitonng and analysis software. ,,compehbeity • ,,2, _y- ._. compatblewnns0-cane modules:, _ ; Communication Power line PRODUCTIVE SIMPLE R E L r A$t. - -Integrated ground- -- - i The DC circuit meets there wren ents tot ungrounded f v arrays in - = NEC 690 35:Equipment ground IS minded in the Engage Cable,No`,'' -Maximizes onergy Production -No GEC needed for mictoinverter --More than 1 mitten hours Of testing _- -. _ _ ;- = _ additional GEC or.ground is recused Ground fault protection(GFp)Is Ar -Witemizes impact of shading, -No DC design or string calculation anwets millions of tts stepped . -- Integrated Into the mtcroliwerter. _ -;- -. _ Mordonng Enrighten Manager and MyEnGghten monitoring options drat,and tlebns required Industry-leading warranty up to 25 `Compliance - r - uLt741ll0EEi547,FCC Part 15 Class e:CAN/CSA-C222 N0.0-M91; -No single pont of system failure -Easy mstallatan wipi Engage years Cabs , -'Frequency ranges can be extended beyond nominal if required by the Maty OmCvaan No . pevAn3 BV_ Rev By Dale TIMER 2013 - �enphasen - S�• To leam`more about Enphase Microinverter technology, 1 enphase" SOW CAD .E N E R G y Cl1S visit enphaae.com L ] e N C R G V Cr 2014 Orese-&tem M rittewn+:,ni,Slminerls tt mode n hi.h i4s.0 n i wetm+lereotw nr`drir4etbenerer -- ELECTRICAL LINE DIAGRAM PV-6 nrg . w _ �� � ase, CABLING ACCESSORIES - DETAILS and SPECIFICATIONS Home � ROOF Cab :le , <,. - 4 t - , � � "'£�z DIAGNOSTICS qq SOLAR AND ELECTRIC LLC - - "` '` • . Voltage Connector Spacing Accommodates PV module orientation - 1 240VAC.4 conductors 1025'meter 140'1 Portrait 4oteD p pe, _ _.,_ _ ' '" ` 240VAC,4 conductors 1.7 m_ter(67'1 Landcape •'�% A do ,...• ,,,rfrFg�� eo spa 206VAC,6conductors 1.02Smetei'(40'1 Portrait '" Cr ��,, `ss* ,z-r ' ` 208VAC,5 conductors 1.7 meter(67'1 Landscape it ,1.- * M1 'r Vs 0g. �P.'St C , ,te . tai '.`. IiD xta ,- �p)4.:t+E`t''' P" Aj%4(sp �r'I' 4 Descnption Rating Model Number Orientation Connectors Appro,r weight • 'i Cable temperature rating 90`C(194°Fy wettdry ETIO.240-40 Portrait 40 40 lbs � - Cable insulator rating THINN-2 ETI7.240-40 Landscape 40 45 lbs ` „rc ie-, "AW. .(. UV exposure sung UL 746 C,Fl E1-10-208.32 Portrait- 30 30 lbs 1 i. n arA 'S. Conductor gauge 12AWG 6117.208.30 Landscape 30 35lbs w "'4,-.06' r. Compliance UL1741;CAN.'CSA 0222 = , <' Nos 0 2142,65,153, 'additional lengths available through Enphase authored ,,�` • ,.V- �` ,�. '' 1/32.1,1822 and 1823.IEC distributors • s 405291P67 - i s ,. .S 1,. 986 _"£rc�e ,°"lzalkillie -...,r,.- .,: r.1�``. .. .`.'--.z . .„ °' a. - t2i 0 c a soa n t ,,y;" Q L f o m a Branch Terminator ,r Disconnect tool W N I V _N. ,.., �,�.�q r c One terminator needed per branch crit °lar,to use at least one per mstallatron p 0 The Engage Cable is a continuous length , GAGE': ) T-TERM-I0(quaMtty"10} ir� i. ETDISC-05(quantity 51 a _ CO of 12AWG cable with pre-installed c --'-ii:-:",'1 connectors for Enphase Microinverters I to-plug into The cable is handled Quick installation like standard outdoor-rated electrical FAST' -Large branch capacity Watertight sealing cap t_�: •u'r Cable clip wire,allowing it to be cut,spliced and Coe needed to cove each unused � '�i_..--- Many needed to fasten cabling to,the O'''ff connector or the cabling ' racking auto cemre looped cabling extended as needed. '' Simple design ET•SEAL--10(quantity TO) ET{LIP-DO(quantity 10a) FLE I L1 ! -No additional cables 1 The Engage Accessories complement the !� I 142-00013 Rei'El Engage Cable and give it the ability to No high voltage DC . adapt to any installation. SAF E L-Reduced fire risk Cravdne No Enphase Energy,Inc. oraoans a,_ Cie 201 1st Street Rev By Petaluma,CA94452 Cate 20 APR201S Phhoneyone:877-797-4743 SOLAR CAO C US Fax 707-763.0784 ._n, s j - " i, x'v �"y;. s.14, .,-a` )ri, rrnrrr >r-rroyrt"rt _ w ' _-.:..- `- ---i..--g Z ",aelix- u ,., fetptIrry,nurah: v o m SPECIFICATION DETAILS - r, PV-7 - nrg ` SOLARMOUNT Technical 'Da•tasheets- it I Horne s1;,UN� ,AC uluracCade-ConplirnULurallationManual SolarMount ' . ,�.• :' s SOLAR Part III.Installing•SolarMount SOLARMOUNT Beams ROOF - Part Na.3101320,3101320-Et;310168C,-314168C-9,3101680 DIAGNOSTICS The Unirac Code-Compliant Installation Instructions support applications for building permits for 310208c,3102000-B:3102400,3102400.6,310240D, SOLAR AND ELECTRIC LLC photovoltaic arrays using Uniiac PV module mounting systems. 41014481 4loi68MPl,410204it1;A1024f)R1 trsea AR This manual,SolarMount Planning and Assembly;governs installations using the SolarMount and lea °er4,.i,, SolarMount HD(Heavy Duty)systel'ns. Properties Units SOLARMOUNT SOLARMOUNT HD a F�,;t- -.... 2i Beam Height m2 5 3 0 ;-•}1, --j}_ * [3.1j-SolarMount rail components Approximate Weight(per linear ft) pit' 0 811 1 271 'try, eass90+aa ..•-- _ - Total Cross Sentionni Area irP 0 676 1.059 O r t+S`K ` ate yp � �� "' _ .-,,,� �•.--3a o - Section Modulus(X-AXis) in' 0 353 0 89B '"F r ® Semon Modulus(YAhfs) In' 9,113 0.221 K - % `.«�e`' i�'' Moment of Inertia(X-Axis)' in. 0464 1450 Al t� b 1 ,„iii, fz � ':yam.'. r '- " - t ,„e` •sa%^' r '1�. ,``..» MorrrontofIneroa(Y-Ads) iM '0044 0267 y ai ®,. { '.._,:•••=...„.;i: Rados o1 Gyration(X-Ams) m 0=268 1 170 ';-' F(Cmr 4.SolonVount standard mil components. Rectus of Gyration(3-Axis) In 0254 0502 2 - ®-'' •Rafts are zarudedasi-ry Ow al ifttrmllta)s 60115-T5.6105-T5,dO61•Td0 ,, w17 m O Rail-Supports PVmodules-Usetwo per tov.tOf lock washerforatrachingL-fmt.Flashings•Useoneper Q . f? c O1 modules.Aluminum eXtrusicn,anodized. standoff.Unman offers appropriateflashmgsfor-both ._, - - - -f - _ - v N _ o N- srandoff types. - ` ®Rallsplite-Jatnsandaagnsradsecnonsintosingle Note:There is also a flange typestandoffthatdoesnot - --- " r5 =-LL' ~" -• length of tall It can form either a rigid or thermal require An L-(trot. a expansion Oitit,B niches long,predrilled Aluminum' ®Aluminum two-piece standoff(optronal)(4"and 71 - ;RS emtusron,anodized.' Use one per, Two-piece. uminumeztruston Includes 3/a A- "s3/4'serrated flangeboitwithEPOM 80TFORT-BOLT OR - 1.728--1 ®Self-drilling screw-No.10x'1. washer for attaching L-foot,and two 5/16"lag belts: t SLOT FOR T-BOLT OR g ( '�-,Use 4 per rigid r/•HEX HEAD SCREW Splice or 2 per expansion Joint Galvanized steel. ` "hIX HERO BREW ®Lig serewfor 1.-toot(S/16'")=Axachesstandoffto. tafter. 4O OM FOR SLOT FOR fr..] Q L•foot-Oseros�:curera•Isettherthrough tooBng BOTTOMXSLFOR �� 2•�0 FlOTfOhI CUP FOR materisl rebuilding suuctureor mandolin.Refer to TopMoundng Cladrps loading tables for spacing.Note.:-Please contact Unfree r I I 3.000 for usnand apw8:adorofdaubieL{ooe., 41)Top Mounting Grounding Clips and Lugs jr" ' 1.316 ®L-footbolt(3/8"x Y)-OnecneperL-foot to secure SLOT FOR I i - rail toL-foot.Sfainlessnteel. ' I �T FOR ' L385 -Installer suppliedmaterioIs: "e HEX BOLT { 11 • Lag setawfor Gfoot-AttachesL-fooiorsandoff to 3E"N8 BOLT a Flangenut(3/e)-MG one per Lfoottosecurerail to rafter.Determine ehr__length and diameter,based onpull- 987 L-foot-Stainless steel. =values.if lag screw head isexpaedroelements,Use - 750 stainless steel Under tlashmgs,zine plated hardware is I-107 o Flattop sianduff(opaonal)(3/8")-Use standoffs to adequate. Y ,. 1.875 Drawing N, increase the height'ofthe arrayabov`e the surface of the 1 1 Drawing er- rod o:to allure for the useoF6ashingc.Use Dneper " Waterproof roofing sealant-the a sealant appropriate i-•e X "- X Dana Be 29 APR 2413 L-lc5t One.piece;Service Ccludesn4(very mere) toyourroofingtnaienal_COnsultvnthth�compan� SOLARMOUNTBeam SOLARMOUNT HO Beim zinc-plated-welded steel,-Includes 3/8"x/,"bolt with. torten.yprovidtngwarrantyofroofing SOLAR CAD Be. Dimensions reacted In inches unless toted 14 SPECIFlCATION DETAILS '- .,os PV-9 nrg ' jj Home Mono Muhl Solutions C- ..^ - . ISM-PA05.08'THE UNIVERSAL MODULE SOLAR ''k1 " --' ' I , ROOF ' ' I J - - - `'"" ^ - TOM.192 154-260 ISM 770 '154415 t3S2.259 DIAGNOSTICS fn4EHtibYi et M°DUT[TSM.IA05A3�` ESECtPICAI PAIaG STC ' r 7 - 7A05,06 rA0:g7 PROSrP PR050A ?AMU f � , - _" ' SOLAR AND ELECTRIC LLC '-7 4.7.''r ' i `'4 • - _ 9+In - 0ee770740173f1iA'.0 PYat 2e3 -745 250 _ 256 _ 260_ 'I, #1' �,'��- Pa+.erOvtWlae'.e�+exs Pw•P-1 Ol�i m•i- - ori,.=iii-1'.---751.S.--'-` psis ARa -`}+3..1 ,• - I _ a di•' fM Ppxer YaIoQCWM •-297 m.2- 00 22-1; 40.7` yt�'P f,Pe,.4;j� • 1 ` �v. ;h .2.' P C 102-..•[H 910+-tet'en':17 B2T"" -Blt, - �'6 k✓`� 0, .7 Y`,,,� T 2- T=• '(• - � ' OPCn[hc i Va lnpe.Yxf I i '77)`< ]75 7TT N 7.P SC S.qyl •l Petr_y, }6 r i• 11 iii `� I I sI=ITrcu?CvnMWcIR^ -.--8.62'„ C0;� y`ee5_, §-,,,,,,„_,:.642-, ,* i • ,, • I 6 `y, t - • 't .E . - •:4 'N00.S'Stle t 5-25j 47 ISO 1i.] 156 •59 a i. '�■-- 9 THE UNIVERSAL MODULE j i = AR °C1.;�¢'s^ C IS��L C,a.7 �9T 0]5400 4 .em,a••eeea ee:_xr ontev •a•..+eroe.. FOP 7.10 • i l ( _ 1- 1 - _ y �, - - MY:. 154-265 734.10 ISM 755 TNS 260 - 1 ,LICCIn045OaTAYrtCCY PAW 00 PAOTIA PROS 05 PAOSCd 752546 •1 . V2-. p .,. , , I '<r` - '61yYgpin PaWr Po..Uvel IF _ 170 IBI -Iet jag T 3- '`60�CEL �P'. �A, .[g I'' P ` j _ ;�.^� Na tinvm N'.orYmia30vvIvi; ,,.26`6., 76e'; 270 272 ',27.1^-, f1�11L17CRY5�bALLIRRwaaEMODULES` 'a' ' i' I , ••'` . +;A n (MP..munPox<r0525Sw IAI 655 • 66. 670 b- 626 , 'x,11 d 5 r_=••ate- 2-.0.0. mnivalait Miles IVI V"_ su` k. T:__5a2' -i< ,'.Jd°A„ _. _ ._ _ _ I 147- Mon CNC°I Conant(Ai-I.e IM 7.2„ 7.10 • 725 1,_-34731•-` •737< i_. �{®�' .r„ -`.s - 91bzn 'leo ucne�eet�.iwo..<v..mue,rl..s.,mr..:-c.nmt...cl•.n 240-260 i-• `02[[Vw .,POWER,OUTPUTRANGE` ''�-' - _Out-mostverslliie product - 75SCRAwaSDA% < - ,- �; 1(�6¢,}; •Cam`ryollbte\1IIh:Sll alit-nolo,1I 5 can',noner,li and Fyste00 rnn����111 sesareef>a .Mw1<rnlw.aa ISA 4126 mm e6l'sne'i - 2 \'itl'PoJ/�,' designs. t _ _� _-r,-` _-�` ((�n O n�., < �Oellaybn+a9a0- "60caib(6tt01• .: , t., � fO m n "�w�_ Mid)950PS'ans 1657.192.25,v(6J%.7P 05.17/jna an`` -�{ O J = '(i "1'5'9%', ,-r ;55155 _"s;lcaeB lelataq_ d.", "i;.,`�, - MAXIMUM EFFICIENCY - F;s,.., kA Glos "•16ontv0Pem,241272fgA 21,41a.uw.5al _ _ -~-7 I- p- 'M 4 One of-the Industry's most trusted modules - 'Bses'.. _7' _F"'e'... -,"'._�_---, ,,,,,,,,, , , ,,,,1 w CCD o5 ' - '" "`t 1 �) •Ove•2GY.said across atl marcor glossa(mar•mis Fon; - 3.....ofamlN Alloy - a 0 Q r _. - 1 _ •F+e_la FlS+en P"IP4imoriCS b1-eos,- ,.IP65ur576?o5 d ,~'� _ :_••Y a iJ 4V CpFtEi OE rYM000'SifM 269 PAIS 03--Inn:;0,4+3'7' - Coble --• PPelevelbvT,araebis42.5440mm•Lae06 Inches'1 ' • ✓ %POWER',OUTPUTGUARANTEE, �'.. rw uroamm(59,itfe----_,y ,0 _ '4a'� .� _ ycomMS7a^.. _.-.,..1.011graI6106+i P !,_t 11 l'. ., , Highly reliable due la stringent'quality control ?6•'-S,L.5, - I --,1 ' AAs ciro21 fi pbn[d rlu:n;ilcOhi•e•• •OYar 30 in-house 1°su(UV;1C.Hf,and many TnarLe)- 6•' - , - --{t gene'Ct`Gni:ltuto,cite.' - . -- '337.4.1LCO td51ind S,tCCS watt beyond cer LflCanon rectumslents V>^ rRJ+rfien - ndvSCzauttAIULE 1090,4 MAXIMUM iFRl.Sw rrC-C v.'e heSe05 Clare - - - - 2a, ,: Y _Y -. Nmnxt°puck,ry Ca9 WC 172.4 Opa+ck beat Nma.uaYq .42-•55.0_ •0251 02.47-smdM PD/fnPli ipmpa0•Y'O 140047 - . _ 6•eslnsm S,sMet'I -15275051CY5 e•= .TCrrparovRCa613 eo'Pwy-D U7./'0't •Cc iso = d�'D�N4 lTC-+'✓✓[d i_f':•.`JGCCSS MCI k,CCI - _ 0.• ,Sv _ _ae Y1T -a• _ _ _ _ _ _ _ _.. _ ,,,_ onisen2earos-nn ITS,51655.1,vs o-- -"` .. "'-�'"�J \y M iomperofve Coe12,2271e1 Vac -mused Max 5eries 1,10051200 ISA 02452 . ,cete Ill puree e.eS5^IXustsaidte " ' tococn�usta-0/t511xh`1,,.VIn1 - Certifedlewithstandchallengingenvironmental iompoed-----e,gii� bo<7zrc -and 5i4tOEt-1511/out 11idval/vo'-- 'a. fosautc Mui0ciewgnyet our T"c' _ ', Conditions II "all c'ct:J.asm•w5 bunFabto' - �IL71� '1313Amrh,WO ihod(2400192!iMIRA TI •P00 k Sly .sad Per 55041/TF'154Sa(?a) +, OC;14-12.T'Yr a'c r-Orn•'A:a:.;. - -' q ',29.1•Raetcs wumr4mhawmrcler .05s/305A•a/75f:..rt11ts'al•P - - - i-- _ C91„G:IOSCOECtIoso'tOr.-h - 231Ma+l'•ua-c•siY;mfar,'•,:. ;,, -, 'J'21n9^_1L,d0.+'FCpe:s:Jis`fl;:vl:u.- - 044.44,24,40.:4.444.4be4n,s I` Cnd-.Ise,009/1002 ass�^-D' ' ' . 4 amworn 05;,:,[Snai en l4,CC5P.70, _ , 0Earrr07.11054 - - mi6itPasaaf;e•MrcYrxet!e; LINEAR PERFORMANCE i A_ 'y',� -Y,2i ,SPa PRC[aGItaG CO%CTGiYASioN S - 10 tom Product Warmnfy•25.25 Year r Un'01 Powys'Warfanfy _ - +' +-so _ uoc)e,pemer:9 P'ecm 8 o1'Iwb+p No �' boWeg Sy_ �T , , 45 �E O ,vo.b e,FF.!0'amo_%55!,01r_•ces.;r , 3 Re'By . _ .... _. - •de�u _ - + C, i Vl u,V - Dale 26 APR 2016 .. • . '661604•0#„,,,,M :`' -- / - _ , ' '[" a76tor'Saaep� SOLAR CAD - - , nasty O c.d.-44,4.c 441u•00.;1+°.0_0.74.P:u III246 J1>],S s-cOt.: ' ' eiranasolar- - � , -- Tnnusolar et, st�1,r,. at ,,.V.,.1S:.rr�.-n.�.w,�.sea as..�setaeVPo S-IWITrgl4i Te9a IN = M_s IC 'I 21 25 Fm2•Er+"gY;e•F-f t < `_ - - SPECIFICATION DETAILS 9vmn, PV-8 ' ".-S'--;'', .'"R '1, 4 belles u-u„F Prs7, , ' I: ,',.1.: _ : .: ' GreenFasten-GF1 ...•-,-;-,,,,,,..1, 1 , 1_ �t.�utdz � s,_ _,,,F.,,,..-ii;,.-_,J-11,, lye�: ,1,0=1: Home AAszi : "::E * =R- / i? C-1,--„,-T:,^ 'r ; ,�y,:,-- g..=1 Matxnals Needed for liss�nEd, SOLAR p i - , '''?= a ,. ...:P.,;#1...aaernun oackllonormsten tlumntp ROOF ��i-� <,l`x` y Q.. ',741::-- ?�if"' :. z 41073'BI6R't�e�rnc*ionla �ue t DIAGNOSR�ICS i'1- �g� .FrTbi If € �� 71- t''"IFF A #j. '3 Sr'6rE7.,'tA BlmdeV 31ti1&B45 YAfia t SOLAR AND LLC i ii' !F _t u�Fc �, 4• 49 co)MM. 1 -d ,.r " y ` *"-„wee'.” i�aE°^ec kJ a�-!..=.1';',--_.'lt A � 5 Q e---1-4,....f.1,4- `!;e4,a, -�•+Y,r-}s ��`p8 p,pf}p�h�n J.:a 1r. "i lly; q 2.,yyr� jT . ¢F i s2 t ;iY } - - I{tvF - it.-4'," t.- .'," a' LT i•-•',!'w ',.7.(4W .4,, AegmrMTo11 ,�, -( .k `` �' S 1.:&,-,f.,`.1:', t_� ^t 4"':'''';,,-• ^ `;yg f - rpt, Q. :-4,-3,-.-].!- ;F `� i �,,.y �`' 3�. a. r t--,-,4: s' Saha` } j ''M1Ew,��:,�x `s ,'':,r,.. t-�s �as; f.0 cn,.wax.tmw.orawaizw.,.e.nic+i1.i-_._-..._,_...,._...-.._..._._— m ..;;-. -.Us.,sn.-s4.4$1, atom+m...fu:.meas..vmarxi>,ea:armmanyen:Fetwv--tela.--myarsl:u.+amcn.4saesew.mc W m 7F,«'F:'.-L,'"1-,;-'!--,-, "c C.. -c3Fl-pr:da_s:ae4A err,a,. 61.d:.Lx'lz ;:,;;s:: -4 Gc-1,,.n--Ft-AWyTIUd In<fa9atisnln:naeNansan77 Carrrrs:ion Br.lckat O �1 $1UZ h ` ? e`h,,:re#'.a,41_:,ret.,,F,, ,•:,;)34,-,),,:._<n:3?C),,p•,-,_eq 1-W {+ .,"'''..$• $' r �y.,V a" D. 7 eV f � ff r x x. f iS sg� $ f0 } 1 iald r4;NnquDun0el:nR.gklUMd'eidY.g edge 2.Ram0✓e911bng 4116 Ci^fnntQlatmslosttfe lltdshits z:?�,:_t of ,-.1.,,,,..,-,..;: y #f y' t" i Y1!' t ✓• .$y � �--,41.7-,--:-'-'-'7.''',7.-�. r'.''4'.776. tee M+.emsc ar•,h 9 Kip. •$.� -v 31rak �4S ri'a/wr�i,X G,.�+. f"`@ a . $�, w 1i i•t } t` gy ] 'Y ' S' llY- ` .-'1 g ,r;•- f 1 --� 1 to CODer0011ndltNpnnr2enC 104 emCA IA,10ta maRt0elMgnM ADO,kOnidr ;n- a c-`-�'.-:,'.,:$'".- ' l ,``, 1r.-„ age v10)414cnNammmng. - ;` '1"7" k _ t :-'4 WIC :....:7„- tl d.'c`3 may+ # ,.. zotul l pilot halC1ANItretalJMmaNg00R ea<it,RivNn rNunGEWIlite Solo- _ �, rammmaksanFAGNtmcnct," I + ::,;4,.,7,i,"' s1- ztrK3+1--. 'c,,, 3-lmcnt04flsA gsemarapp800u+anmeeevmror sMngtcandpumedtaralaug>,,s, -„,r,. ,fY- ,.# 1Spno`peldpleae4mtcup5•rctontnougn vatic,pintmmll�gtc.fieteadng.dgaofJr+`4, 1 3! i R4mmg muctg4tm_emsruppironotnsnitoFr�'an<tuvongwne4mulpuca seepages '1 y kk -6- ,'rr ` 11-/ctMtCatadp.rmaeamt•tNedingtl 1141 nunngnRsnueMVp{artrampemunosY 1-:i a,IdfeuppCOt°1CNwm4 e'f."4 CooIlefimgrult t.7 3.aanit111R41hDgvamnot.al arnupsbpt 4.Poston rotaM kldngec9euMemGtnnYlheadllllmm� ,'„,c•� r"1-` ymleltmefi o0lttntlr -n1FD°nrmmatnet4 com A. .n..•, ,}, ah.,•.sTMvas.is f •. p�'; , 1¢I.347D34'�.SO.-1V(J,Z.IU C6ndyl RIC 9faa'.G,�piodfllNgat e]EAOflIE, pravg No ', 11 s, ! I - "'' - .ate Te1Rling eW IOC the AfterprevAn9By_rot ..7ii { ,,I 3¢,Adel rneiagWRMglgnmaEij4Nnastl.y the CmrplNwnt Stga 1010100 n R�� 4,-,,,,,-4..,....,,,...yrs E' �' ersTE and Da;Wired hien mefa:Rlrg and 1-r totneialte 4 �,ni s Y'” ” g;hltRtman boat ma +q:Flet met,n gale IB APR 2013 1106 ,t`� , t '+ 1-3 I • _ +! ;r�L, 1 9 nrdu9t! rapartybrowstheEPDMeOnded 1'4'1:7.4'; ' '' .t w4snetmeLRRF3ottld Cml2teabRbia Xet f:�the uP6Ed n4,cmtna Rlmn .i' o} •* 'g.c` _ surtm en naa0rgotovrrAw4wnxemaUtmm 4ndnaometaa� 9 q SOLAR CAD _I::-_--',1.;?,',': } �n - i# ien9' ,,,gnats. S:TriNual7nimngeaCm.ae;lWi4okryl.eln.Poundsd4a'ndixJonlhrtYfaeo(coot ti= - ,. 4rdturaffaer.illeveulbdoputra prtp,nazis when the EnfA10n tJt 1n0�lde 4", I. ra,4,'e of!ha ndedrasaa hg s,opushbut ulasdesal trrerashxmmpreuez➢'unngan T'4:p=i`s - 4.,4,-;,-,-4--...-z. 11 ni,pac wend,to[r ea9Uurytendsbe Aterldnot toPMtorque tnefzITas Ycumg I,; ,.,: _.:.7"`=:-iia n4tl112tttpIrCV ea at to Rtlsnlnem ENI, s['e-R'_-' ',,5 `notplaued. SPECIFICATION a - ' DETAILS_wl ._� _� l` ''a:^�`sM ' 1.Ym---,...aclus. — _ 1R ,5z )e,1-_lercr s.r *cas.s, +>P,rorxraaaer� vawn�e+ewnwuvssse< 4raweoru0i.rwme...�ti9awaerucac<n waCti�ses .--..�.. .' -;';1arw.b,aas°,„,..?�cw. ,a.+mtwrrn..ruwa.a''' lLCIJttauGe.lvmae.c4aca,+sncd^>va....mwaa:.nnemwn . m PV-10 ev1v11 . , . *1. nrg Locus Product Datasheet DIAGRAM-TYPICAL CONFIGURATION Home ENERGY, Ilt tuffip SOLAR _ . . iii— '474E •,. ROOF DIAGNOSTICS MINIM,231,11211 LGate 120 •;;-_, -M-',- YA-I-N ,..- „,,,,,,, ,„,••••••., L -.0-..." SOLAR AND ELECTRIC LLC ,i-I, RESIDENTIAL SOLAR MONITORING SOLUTION „ "6`;' ,.41 IFIL:za-1 , \. Plal 3E rAttosivas tr't='1 l't-4 t--' t r---i-et.--i 4k,,-'2.9 f•ts%,10, t 1 2 t "--", . ''..,..tain'ard .. 'L 11 11-: te,, 15:' '•le:"` ; T-I-11 Gary:.Wci-.:;:d&t,tipb-t-pmLtt,-.pl.;trt of..waD-1-0,11. }I ! '3!I emote r7ovito'Ina ot-'ztosa-OictcvcItatc,system!: '; ,[-sic,t,14,,,,,,-tr.:7.11, t• 1 ELECTRICAL A q, 0529 ..,0 .- '3 e 4 zrorrt kyrrttrn,rt:aticmr1:juiet'so a„Kotlitt.kt1"it t-,4;1' , !"M411Lr,4 1,nhz 'iM 1 , _ . SERVICE or Nei — - ionk,Fi .,, - INVERTER(S) LEATE 120 • -TFirim At?ter data(wecri:-ei t..ar tt:It:11-tirntitt.rcItAqt-it'i ,,,--k,-i.,--r",--' -i si.i..--iii,--,..;-,44i:-.4L,--- '- •' PV ARRAY ailowirg zystem Ow,tte arid orttat'cearstc casittrartagte, titittrimtel sorty Fzbatt:' 1 DIMENSIONS . . 146TER,A4 --'::CLI)OFIliiiler014DeiR6YLL'':' ''1'-t'=-14"'(611":°("11LEC- • 1:- >, The LGate120 comblnes-a revenue,grade,solid-state power meter wit tran advanced communications-gateway. a et in*1 11 je, 2 o . These components,work In conjunction to remotely,monitOr the peifor(nance of residential solar eneraY installation - ,..,-;Z:",''. -- ., ,, iu a . regardless of panel or inverter type.The LGate 120 is a one-place completely under glass meter which installS 4 it' Olin • eL easily using a;standard racket base,Performaite data is uplOaded in nearJea Rime to the LoCus Energy SolarOS ' .,':-:;,:-.-' -,— , .. It-ill - L' '--.,,,.riii 1 t hi 1- cu = 5 monitoring platform which provides a suite of tOols a nol'analyLcs for asset managers it --)19•14 •iis..e.,• ' ,6,--, "--3,"5--ie- , ' --1,-, in cp o 0 n 0 cn - , , -, '' 0!.:•'.„ , -%-,-1 ,, ,_--4,4i5 ,-, .t-4-S•IS in--14 Posts---.1 DATA COLLECTION , _ „ ..,/.'- -' 7fn Ei ._ AC energy data is collected by the meter and passed to the communications module Additional systern, Performance data can be collected directly from meteorological sensors and supportedinverters via RS-485 0-- Zigbee connections AU data is stored in non-volatile memory and then automatically uploaded to Sob rOS a t user ____-_ _______ _______ .._________ ___ configurable intervals, SPECIFICATIONS riApu,iniimi , POYISR MOIR • 1,Pzeceeace,`„ ::ARKel'etrareddrl Ci•li',. ,„ :' ,'1 -, ,' - slieuracyr ,: "a lb*20 craiet2% NETWORK CONNECTIVITY OS ..- - ,Custoin voslonar Lin ux 2 0,ETA fildrIlar'R audates '--Vatige lode 12ii•Ago VAC2-- The communutions gateway Inside the LGate 120 supports plug and play connectivity through a celliilar or Ethernet ;,144116.iy '' ' 1281':111kAt•i ' r•- —t "l , ' r". '-, - Plane,t T.•S weilase Sergi-phase at 50 Se e0HZ network connection.Once the unit is installed and powered on,it will Immediately begin transmitting data without Di pray ' .LCD semen -- , ' . . Socket'Nye . .3n any configuration For maximum reliability,the communications gateway will automatica lyroute uploads between the Vii ' tOterujoiti. . ' ' wireless and wired connections if either of thesietworks are Unavailable., -nsiesi9 aiida wif,'' ,.„ - .: i ; _ ,ANSiT22DDESS 024 , ,„Ire-pup FccnarIIsR . • .r _ :,,.. ' -;• A: _ "'••• , FEATURES , ATLI and Conniincs - -- `,-',-- '- ,f,- ' 12171 COmmilnionl IONS • ANSI C12.20 power meter • Low cost installation --rinn t-. -;,,-Rw510i100E1tArnat,tarsal dupe-.onto yoNnty-_, -:, PIMICAI2 SOLAR CAD • RS-435 and-Zigherii.inputs • pon't require entrance into the house Cellular, - us GirM t., , 1 l" ' :"." - `, -ElleperliV. .f,.[ItittA„TRT;DN _ 2, _ :,-,,, ,_`,• '-'- .... ,. •GSM cellular or Ethernet connectivity • Plug and play activation _irthioiLiig_-' 'rao il-%0•_, --- '.'' --.:-' - . ,.,Warght - Eu.: ' ' '' - Over the air firmware updates • Configurable data uploadinterval Drunanni,"-6 SS-x-e s-IC'Zr-' •r - ' :, - r •''' .Errenme et 20 to'70C SSi RR non!;(1Incl.AnnS f, ', , SPECIFICATION ' yinaniy -,S year IannEl tovianri, ' " ' DETAILS --,-,--- ___- ,, ,- • , _ ,,,,- IiiiMMIliliiMill IliMEMMI— WM:1M PV-11 . , Tom Petersen Architects • Planners Construction Official: May 6,2015 Building Department for project at: 23 T Dry e 22� IC q��/�0 H ARBOR. L(/4��N.��E I .. . .. I.--- CVk\O@1U4 S Re: Solar Panel Installation Pfaff Residence 290 Harbor Lane CUTC4{OC7OE N4 L tq3 7 • Dear Sirs, I've reviewed the proposed solar panel installation at this location to evaluate the existing roof structure and the connection of the panels to,the roof. Criteria: Applicable codes: 2010 Residential Code of New York 2001 Wood Frame Construction Manual Design roof load: 30 psf live load, 15 psf dead load,45 psf total load Design wind load: 120 mph,35 psf;Exposure Category`B' My fmdings are as follows. 1. The new solar panels will imply an additional dead load of 3 psf. The existing roof structure (2x10 lower and 2x4 upper roof rafters @ 16"o.c.,with double 2x10 ridge,span=+/- 12'-9" and 16'-8")is sufficient to bear this additional load. This analysis is based on the existing single layer of asphalt shingles but is also adequate for two layers. 2. The solar panels are attached to the roof with the SolarMount-1 rack system by UNIRAC. The rack system,roof connections and connection spacing are rated for 110 mph. This project requires the larger Solar Mount I-2.5 beam(2.5"high)and spacing of flange foot connection to roof at 48"o.c.maximum.Flange footing connections to the rail are not required to be staggered. The flange foot connections to the roof are 5/16"diameter x 4"long lag bolts. The total panel installation is no higher than 6"above the existing roof plane. It is a violation ofNYSED 7209 for any person, unless acting under the direction of a licensed professional, to alter an item in any way. If an item bearing the seal of a licensed professional is altered, the altering licensed professional must attach the notation `altered by'with his seal, signature, date of alteration, and description of the alteration. I therefore certify that this installation complies with the applicable codes and design loads mentioned above,as well as ASCE 7-05 and 2011 NEC(including Article 690),and is acceptable for approval. Please let me know if you have any questions on this information. Thanks! -eED AR Si I cerely yours, C.0 PS V. F' 7-',.p y/ ' * Aga * Tom Petersen (� (J '—LrXf ELF o� �� Cc: Kelcy Pegler,Roof Diagnostics•• 9�F OF F NO9 y0 6 Country Lane•Howell,New Jersey 07731 •Telephone 732-730-1763,Fax 732-730-1783