Loading...
HomeMy WebLinkAbout39013-Z ,�'Q�ps�fFOl' coG-w Town of Southold 10/23/2015 t1 tt P.O.Box 1179 1 0 1,1'; 53095 Main Rd 4 o i' Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 37859 Date: 10/23/2015 THIS CERTIFIES that the building RESIDENTIAL ALTERATION Location of Property: 56985 CR 48, Greenport SCTM#: 473889 Sec/Block/Lot: 44.-1-29 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 6/25/2014 pursuant to which Building Permit No. 39013 dated 7/8/2014 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: DECK WITH HOT TUB ADDITION AND WINDOW REPLACEMENT TO AN EXISTING ONE FAMILY DWELLING AS APPLIED FOR The certificate is issued to Ferrara,Daniel&Ferrara,Danielle of the aforesaid building. - SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 39013 01-07-2015 PLUMBERS CERTIFICATION DATED 2 Si:Yre , S�FFut,r�o TOWN OF SOUTHOLD /4" BUILDING DEPARTMENT ti z TOWN CLERK'S OFFICE SOUTHOLD, NY \: . `A ¢ BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 39013 Date: 7/8/2014 Permission is hereby granted to: Ferrara, Daniel & Ferrara, Danielle 9 Colonial Dr Glen Head, NY 11545 To: Residential alteration (new deck rails and window replacement) as applied for. At premises located at: 56985 CR 48, Greenport SCTM # 473889 Sec/Block/Lot# 44.-1-29 Pursuant to application dated 6/25/2014 and approved by the Building Inspector. To expire on 1/7/2016. Fees: CO -ALTERATION TO DWELLING $50.00 SINGLE FAMILY DWELLING -ADDITION OR ALTERATION $200.00 o':1: $250.00 ItS :uildin• Insp- - Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings,property lines,streets, and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal(S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1%lead. 5. Commercial building, industrial building,multiple residences and similar buildings and installations,a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings(prior to April 9, 1957)non-conforming uses, or buildings and "pre-existing" land uses: 1. Accurate survey of property showing all property lines, streets,building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant.If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00,Alterations to dwelling$50.00, Swimming pool$50.00,Accessory building$50.00,Additions to accessory building$50.00,Businesses$50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy-$.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy-Residential$15.00, Commercial $15.00 Date. Cel (-1 i i q New Construction: Old or Pre-existing Building:di (check one) Location of Property: SZ 1$� irk J LI1 0 k't"^o t� House No. Street Hamlet Owner or Owners of Property: 1-it( (2 . Ce.rr-ci Suffolk County Tax Map No 1000, Section 1111 Block ( Lot 2 i Subdivision Filed Map. Lot: Permit No. 3 f o\ 3 Date of Permit. Applicant: Health Dept. Approval: Underwriters Approval: Planning Board Approval: / Request for: Temporary Certificate Final Certificate: (check on6) Fee Submitted: $ 0 Apilicant Signature ,,,, .., r0 ezkw®fr soUry®l _\ e ti O Town Hall Annex ; Telephone(631)765-1802 54375 Main Road ; y \ Fax(631)765-9502 P.O.Box 1179 :\ ciL7 . 0 roger.richert(a�town.southold.ny.us Southold,NY 11971-0959 ly0OUNTY,% .° 1, BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION Issued To. Dr Ferraro Address: 56985 Rt 48 City: Greenport St: NY Zip: 11944 Building Permit#: 39013 Section. 44 Block 1 Lot: 29 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: Raymond Electrical - License No: 5141-me SITE DETAILS Office Use Only Residential X Indoor Basement Service Only Commerical Outdoor X 1st Floor Pool New Renovation 2nd Floor Hot Tub X Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures HID Fixtures Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel NC Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel NC Blower Range Recpt Fluorescent Fixture Pumps Transformer Appliances Dryer Recpt Emergency Fixtures Time Clocks Disconnect Switches Twist Lock Exit Fixtures TVSS Other Equipment: GFCI protected disconnect for self contained hot tub Notes. • Inspector Signature: '- -c---4 ------VL.--d Date: Jan 7 2015 81-Cert Electrical Compliance Form.xls ,3L145 *of IyCOUMYel ,�'' TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 /INSPECTION [ FOUNDATION 1ST [ ] ROUGH PLUMBING [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING / STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] CAULKING REMARKS: =-1 - - = NACal /6/2" DATE C INSPECTOR 3 ?0/i &____ ,�,,i0F SOUToI. � y , �OUNiV���' TOWN=OF -SOUTHOLD BUILDING.DEPT. 765-1602 INSPECTION [ ] FOU DATION 1ST [ ] ROUGH PLUMBING [ ] F NDATION 2ND [ ] INSULATION [ . FRAMING /STRAPPING [ . ] FINAL [ _ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] CAULKING REMARKS: if- ii4-411`1,t- del ,-)c---/4-tr _ ov ) , DATE INSPECTOR ?oi: 11‘ ,,,,,,,,,,,,, . , cf�Of SOUryo ` * #izi TOWN OF'SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST - [ ] ROUGH U MBING [ ] FOUNDATION 2ND [ ] I CATION [ ] FRAMING /STRAPPING [ ` FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE V LATION [ ] CAULK G REMARK �f C S Ad ,' A eE--eia_t_ Co ( - 1 crntejo ck-f Mgr" rcf:i& r A 7 • DATE I INSPECTOR A4--)c 30/3 „gie 'of , AF. �y00UNiV,�,,• TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ GH PLUMBING [ ] FOUNDATION 2ND [[ FRAMING / STRAPPING [ L [ ] FIREPLACE & CHIMNEY [ ] FIRE AF INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] CAULKING REMARKS: C(1 DATE 7e/Dyff INSPECTOR '�� • . . 'CO. . I FIELD I SPECXON REPORT DATE N 1 TS • •-__-:... AD )1- fftf6 6, 7e!,'„' a ?4, 0%....f. ,,,-__-(9_ 1 ,...,./. ) 4 1 ' EOUNDAfON(1ST) p 44 • FOUNDA,I`XON(2ND) • 7 •1-4# • . , • ROUGH FRAMING& ..,,Qy PLUMBING • T , H • • • INSULATION PEAL N.Y. `i . . i STATE ENERGY CODE • • .. /6 4400? sj MIA," -c)1 . 7•;5076;e'7:- • ' 2 C 2'I- CÀ '9 .• iJ riA3— ' • C(725-M Q2:3 -./*3- if-',t6 - G.• 07, •••. 9=-4' - FINAL 10/4,1 -4:1- Ciec- ; ';'' - �,C � C', - -;, 7 . . . . , . .. . ,. . ,- ,-,--- ADDZTI(3N ,COM11?F�I TS {2)6). (-ici Ike :gS3nk 40 .A"?.?. ./_ .°7,._ V:(,0..// Y.. ; , .. 1 t yii I f V .0.4 i ,0 ', 1 r i II' i a1P-00114, I 1 1_1k, $ �. %st i I 1)0-====----..,-..? ,, ,,_.303,.2d)1-: S553 , in - _' p ' -, 25-0-66. . .,Q i -Mg �z J. . 0 , • 1 . , l^J TOWN,OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD, NY 11971 4 sets of Building Plans TEL: (631) 765-1802 Planning Board approval FAX: (631) 765-9502Survey SoutholdTown.NorthFork.net PERMIT NO. 0 [FCheck Septic Form N.Y.S.D.E.C. Trustees C.O.Application Flood Permit Examined �fi� ,20 TY Single&Separate RECE WE -, Storm-Water Assessment Form Contact: Approved 7/V ,2,#)‘1 JUN 2 5 2014 '-'1 Maiito: Disapproved a/c BLDG DEPT Phone: _ 1r ' ! S►."'OLD Expiration /7 ,20 / , Nipirvir Bit 'ding Ins.- • d APPLICATION FOR BUILDING PERMIT I l Date (.01 q `�1 C� , 20 i q INSTRUCTIONS a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans, accurate plot plan to scale. Fee according to schedule. b. Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f.Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date.If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize, in writing,the extension of the permit for an addition six months. Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York,and other applicable Laws, Ordinances or Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances,building code,housing code,and regulations,and to admit authorized inspectors on premises and in building for necessary inspections. ignature of applicant or name,if a corporation) 9 10i\7cAA pc . Gi_A (-.ecci, NH (Mailing address of applicant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder 4\4(3-'2-'1\-- FU r (:)W,a\-a1' Name of owner of premises .J 'z 0-A 0- . c rce -a- (As on the tax roll or latest deed) If,applicant is a corporation, signature of duly authorized officer (Name and title of corporate officer) Builders License No. . C.7 9 /C' Plumbers License No. Electricians License No.. Other Trade's License No. 1. Location of land on which proposed work will be done: STO 9 Z'S— , R0ALtit 500 klvo ',kw House Number Street Hamlet County Tax Map No. 1000 Section 91.1 Block (. Lot 29 Subdivision Filed Map No. Lot 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy Se tg_ ratvli &Acs .. b. Intended use and occupancy �-, . C 110 3. Nature of work(check which applicable):New Building Addition Alteration Repair -( Removal Demolition Other Work (Description) 4. Estimated Costs 14:5- O� O Fee (To be paid on filing this application) 5. If dwelling, number of dwelling units Number of dwelling units on each floor If garage, number of cars .1. 6. If business, commercial or mixed occupancy, specifnature and extent of each type of use. - 7. Dimensions of existing structures, if any:Front Rear Depth Height Number of Stories Z, Dimensions of same structure with alterations or additions: Front Rear Depth _ - Height-. , Number of Stories 8. Dimensions of entire new construction: Front ' Rear Depth Height Number of Stories 9. Size of lot: Front . Rear Depth 10. Date of Purchase Name of Former Owner - 11. Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law, ordinance or regulation?YES NO 13. Will lot be re-graded?YES NO Will excess fill be removed from premises? YES NO 41/4"-- 14. 14.Names of Owner of premises -k Cerfc,r4,Address Phone No. Name of Architect Address Phone No Name of Contractor C )G T CCAj cthA - ' Address c:n ZeA-u--1.64.fryte Phone No. (i -57zQ 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO * IF YES, SOUTHOLD TOWN TRUSTEES &D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES . NO * IF YES, D.E.C.PERMITS MAY BE REQUIRED. 16. Provide survey, to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. 18. Are there any covenants and restrictions with respect to this property? * YES NO * IF YES, PROVIDE A COPY. STATE OF NEW YORK) SS: COUNTY OF ) J e \ , O cQ being duly sworn,deposes and says that(s)he is the applicant (Name of individualnsigning contract)above named, - (S)He is the (Contractor,Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be performed in the manner set forth in the application filed therewith. ‘8.7wcznIGA before me th's CONNIE D.BUNCH i t�1, Notary Public,State of New York day of �v� 20 1 4 No.015196185050 (\ _ � ikith. 1'1� �. Qualified in Suffolk County Notary Public 'gnature of Applicant c. ••''�°5u � STOR-M\WA.T)ER Scott A. Russell ••,� SUPERVISOR 1 MANAGEMENT ENT SOUTHOLD TOWN HALL-P.O.Box 1179 . p 53095 Main Road-SOUTHOLD,NEW YORK 11971 ' 4-XO.1 0 ••• Town of Southold .• l+���'girss1tar�f��� CHAPTER 236 - STORMWATER MANAGEMENT WORK SHEET ( TO BE COMPLETED BY THE APPLICANT ) • DOES THIS PROJECT INVOLVE ANY OF THE FOLLOWING: Yes No (CHECK ALL THAT APPLY) ITA. Clearing, grubbing, grading or stripping of land which affects more than 5,000 square feet of ground surface. ❑ET-B. Excavation or filling involving more than 200 cubic yards of material within any parcel or any contiguous area. ❑CcC. Site preparation on slopes which exceed 10 feet vertical rise to 100 feet of horizontal distance. ❑(1D. Site preparation within 100 feet of wetlands, beach, bluff or coastal erosion hazard area. t ❑C4'E. Site preparation within the one-hundred-year floodplain as depicted - i on FIRM Map of any watercourse. ! ❑ Pr. F. Installation of new or resurfaced impervious surfaces of 1,000 square . feet or more, unless prior approval of a Stormwater Management Control Plan was received by the Town and the proposal includes - in-kind replacement of impervious surfaces. If you answered NO to all of the questions above, STOP! Complete the Applicant section below with your Name, Signature, Contact Information, Date & County Tax Map Number! Chapter 236 does not apply to your project. If you answered YES to one or more of the above, please submit Two copies of a Stormwater Management Control Plan and a completed Check List Form to the Building Department with your Building Permit Application. • APPLICANT: (Property Owner,Design Professional,Agent,Contractor,Other) : S.C.T.M. #: 1000, Date ct NAME �1— Z1 r� i v( (L ��`V� w„no Section Block Lot rn �� I FOR BUILDING DEPARTMENT USE ONLY Contact In(ormatton �+ 1_ — Rdcphone Numbu) Reviewed By: c� Date: t I26)I Property Address/ Location of Construction Work: 5(09�c Q( Q l� - Approved for processing Building Permit. �D { —1 Stormwater Management Control Plan Not Required. ��a2n 014- �-1 ( Stormwater Management Control Plan is Required. (Forward to Engineering Department for Review.) FORM # SMCP-TOS MAY 2014 , 4\‘OF rD Town Hall Annex 411 Telephone(6�1)X765-1802 /] -- 54375 Main Road (b31)_765 �J 5 • P.O.Box 1179 %, G Q ,�� roger.richert 'o`wn.sOut of50 -nv:as Southold,NY 11971-0959O • DEC - 8 2014 BUILDING DEPARTMENT BLDG DEPT • TOWN OF SOUTHOLD TOWN OF SOUTHOLD APPLICATION FOR ELECTRICAL INSPECTION - : REQUESTED BY: ,sely7 Date: /07/ ' Company Name: Name: y",-.2fo 419"x License No.: Address: /C/ C / Gid D "QeX- / y//)f-2 Phone No.: • ��j�- �` f; • JOBSITE INFORMATION: (*Indicates required information) *Name: / i2 /26,-.- *Address: 999r- � ���,O z /7 Cross Street: *Phone No.: - 5 73 f Permit No.: 39O/32, • Tax•Map District: 1000 Section: Block: Lot: *BRIEF DESCRIPTION OF WORK(Please Print Clearly) - (Please Circle All That Apply) *Is job ready for inspection: iIP/ NO Rough In Final *Do-you need a Temp Certificate: YES Temp Information (If needed) • *Service Size: 1 Phase 3Phase 100 150 200 300 350 400 Other *New Service: Re-connect Underground Number of Meters Change of Service Overhead Additional Information: PAYMENT DUE WITH APPLICATION 82-Request for Inspection Form l V" l pc, g E10100 III 11111111111111111111 IIIIIIIIIII ______ iHNMIIIIIMINIIIIIIIII_r____ ,_..„,_-____....-,___7_.„ imp)----,---.-7-7z--- _____,,....._-_—_, kl 77 TOWN OF SOUTHOLD PROPERTY RECORD CARD mid- 4/S./I �- .29 -- , /,9WNEF 4 m (3/)saes-�- STREET,.6y. VILLAGE DIST. ' SUB. LOT :i t-1(,) , / .'e)P4C-\6 '. '/- 00a kJ 6O ro'P,S-e. / , /- . , , , .• 6 2 1-- -e.e.,,d1-174- i 0 FORMER OWNER, -?,(2'- , ,1 .,0 N ..� E L g �n_f.v, �:� �/1� I Aflohria3 6'- r pr/SPS /v1C. S / �,^ W TYPE OF BUILDING % /2 I,, (4-7/? ( i) /t`, " .. 11/0f0 a-f/� �!`,1/,j- ijC "4- L© , . RES. -7, C1 W SEAS. VL. a , FARM COMM. CB. MICS. Mkt. Value LAND IMP. TOTAL DATE REMARKS pO 0 0 h-,•'''' 1bo/71--- S,o// / ;7t ,t re V .S - sv, L.-r=, .24.�C�u 1l- 7 A - tom I CMCJ / 4/00 / ?/9/aJ 64/83 QC. -.I. ..,AN L( o 1-tA { t24J�-r. -73`73 'om-'308 114,., .,_ ‘ L! G-n i d)cFC v /2/Fa 3 8?CoLi' 12.o.000, r.'‘)C-Z-61v Ic; TY) 1-112..1k\G CkS7 .k.1C_ L_- 3'7 a ld-sU v z/._3DO 7 R a D ,2. /B6 ,/,31/7 ,8 f48?,'.c�, 2 ` I�cr, k3"-AV„;L-t,/j.. �oy�u&ic L-c- .- c, '— ' pI1 p /712/ tS. SCJ,/ gV e D 0� // O ;, Rte!,7—n-,G --/c, /V s 7 C '16 0!) /'J•• ''L �7 'r..- L l' ')I.._-t .:_ ,-,27,? —I en`I Yr) 4 C e:sy-e:r'iel,467�, .-Z65 OG() 1i S,d-7 c7* IL(ooio 0A�. .0 ‘I j ak f\iotG, gr -w (.7.;,6-orb1 7/ /9q mom e, (2A4,14,AP__ .�y def;1; II 3///Z ao-d - L 12-0 --'7 lbs o,-6 t'a des 13Dr9e oo 6/q/ -L 1�Zi� gt/6- (6i es-e e ' Q I (... ,;:z' 06ebtor•-•-•s 1)..) 1) e) --r- -4-e-9-6-; e,/ 7 2- ,w Tillable FRONTAGE ON WATER //$ 6 :- _ a_gzs- Woodland FRONTAGE ON ROAD / /:171 Meadowland IDEPTH .. House Plot BULKHEAD Total �`_-` ' SCTM # 1 )000 - 1-P-1.--- ( -2_43TOWN OF SOUTHOLD PROPERTY RECORD CARD OWNER STREET 5 6,6) - VILLAGE DIST SUB. LOT (11(116/ Rf.NnielleeK(a&. reer1Parf- )0 ACR. REMARKS 7/VO � 12.56,2 qo 7-LOOra P t6or ewe N/ TYPE OF BLD.q0na ( l 160eSe P5/6-" (2-57y /g5-,60 t lo Per��is / �.��r ooh RO'r)a ASS lJ (,:t !�(� i;o viv f 6o 1� esu.. PROP. CL- Q LAND IMP. L) TOTAL DATE `/3 00 7 KQ O 1 i c.v) 511 109 I FRONTAGE ON WATER HOUSE/LOT BULKHEAD TOTAL "...--" - —' 71". ---,,--1 ----77;• i ' 't• • ----,"-- 4.?=-. \ "l;'' •, • 7 - ; TRIM. . _ , . ' ...OR• . _ . --- -----, F„,„,'.'....,1...':; ••.- •,,,;•.,„,:-./..„ , • • ,„„ , , ..'4 • - ,2,-...>--, I = ),,„!..., r•J,7-,": '4.,*.f ..4 .... -,) IIIIII __- - .,.....,..„:„.,........ . c- ......,.. „,..., „ i31111111N111111 , ,.. „..4„4,,..,.. ,,....... ,,..4, .., . 1 IlL I , .. ..„...,.„,„.,„ 1 ,f,„qi5f,7-1.,,„,f,1 p ill e'','1Pfit , 'i• 71, ,-Thir,', '' , ,,.....,,,r t Z.-„,„,---i:x,..e,;::::t,74.:;_ i Ili 1111111111111111111„. _,4*...,':,- ,-- ir- 4-kAT,.,,," ,__ . ,- i -,; Itt:„ ‘ ,,....t... , .;-.- ". ..p.,. .., •, .' '', ',,..1,1 . -7-4 L'17,,-; *-"F.:0 -' --..''', b 1,,•••,,,,, ,„; '.-,„LN- ' 43.i....4,,',.• 4-4.46;,---,„ -,ye 0 •-,:, -..,,,,..-1., . - „4, „ ,A,. slid.„.„ A „L.,•,..*,.' 1.t -jr,! ,l''...;..Nor,..,P4,-......._ lorp . 11.1111111.1111111111 1111111111 .11111111111 III .-71\ --''f:1"• - --—- 'i- ";.--itlf4* re: rei.ivitto......,,,,,,,c1,,,ztraii, ' ME IS1111111111.11) 1 I I ),..4,1r- , : '' -.,. .,.,-.rf.4,-1. --,e:-4.- -— • ...--„.,.9-- ,-e-go,,,-.6ii• : Akt-,•,,,,,',Aft,rtrAv7.74v. v.etz';',4Y - ; • - . ,' - .„4.:„4,04,*.--v4•041,,I.',...,,"Pe. y ,*,...1 1 " 1 ..f.' -1._-1',, .4; - -,-,-:.: ,,,,7-,. ..-,•-•,!. ... _17.*t.,',.r., ,: 4.' -AZ:4'' r-.:7^7 '- :'7.-:%'-.4.4;7°Nt. --"•-•,.... s 7-^ ' - ' ' ' - '11...; 6, t (/ i ,C:1 *1 ' • el'e ' .., . '',.•'-,4ft.'17' -,,taA'" le 1.0.1 7.^ ' It ' 1111.1111111 I ' ° 44.-1-29 11/10 111111111111.1.11111.1111111111.11111111 MEM... 1.1111111111.111111111.11111111.111111111 IMIEMIMI MI MIIIIIIIIIIIIIIIII Mil - ,__ •-e,. 1.11111111111.1.11.11.1.11.. MM. .... . .,3 ,...?.._\." 6 el Iiimmull ausmINIIIIIIIIII ,:.>. „, ---, --— (.6"O6 11.111.11111111 m Bldg. , yo y. z--,) , i Extension • ,.... 1 1 i AT- ...., Dinette / — ,.5-e/D ......), Extension ihZ $0 - PC- Bath ,..,3 K. ,. c.,. ..,,, Foundation 7/, te 2?) -7.34 b Floors / Extensiop i 2?c... Fq /(` L R. I Basement Interior Finish ,511—• DR. / 1 Ext. Walls npire.04- tke 4., Interior P... I ? — /3 2 Heat Porch -7, >"Art ...,25— K.517 i I BR. 0„.c.f..._.‘ for,5 --.•- / ,2 69 7 * Fire'Place _ ? — .1 1- i / FIN. B -perch .. _ m , 644 _ )('3z) ...-- ,--1 , BreezewaY— 9'4•"3 ,4"---zcSO / ••,`(3- — ..t.., Gdarge RoomsRDriveway ns td FloorBR. Patio TDYoPr emRecreation Dormer Roof Room ... 0. B. 77 4/ Total 11 • v � • ...raF,COLo 0/..0.- /OPO n ,/O A990 / S . o "74,,,,,f,,,,,,,,.JoyrvE' C '�'`/`I/� /bN,✓ Cf ',lei Jerzy EAd P 3, iJ e � c3D ��3;TQ //3 yy • s//°s O,,� cb , r,pxtar2g �, Is IA ii. 110, /r.oS U .`1c / / : j6_______), / SO ' cl VI uiii.i — Dunu■ /� w.00iv eo-•S T,pQ SUFFMK COUNTY DEPARTMENT DF HIALIII yiee 1. ,NCV +{ OILY DWELLING OW $• 30• • \ - " I o DATI y IJ�DSO 11 , 4 q� `� 'I i1i a++'Y'd1,4•�`d -,.1'..I-r-.:.,,.'';'Sic,'t.£ rwo .r�eer u' Lt F.e4v: I 0. iS I:r;Lc0 h.vu 9U-o r�ol,¢[+e 4a'vi.u+4�1raeni endlC — Ate...) 1/41 nthei ,rer,4aes awl;e;Md 'w,,ebetAeri ,TV flLiIIIME 4 't IY Ctnd IA Bmeea of Wasterretr Meragement L■J /L_ `�=�' ai 9" I; y e • , ••4 u,, „. Ig /1-20,0' / i wo ti 1.1 �, V1 1 .00:0/30 �II Woo'!'0 f 5850 t,l . �I re 0 3 3 I s y I e 11 M E[(.." Ec or ere'....eegleere fir a.73 ....,We y��i./t�E/'� /,�A//oO�fi �P f�•D �D Opo 4Y.0.YCEjIooeX!go ,'I #i.errft'ao.e El.eo.S i----- /r� ti` .91' ' ' ;�,c °a F tow" lh`rr�' PSE OF NE{y Y0 ��‘E OF NE'{ y� co gk,ES R.� 9,f c°/,,ZyES R. 9� , q,. _ w 4iq K, of / 2 PP9/ 0 f° / e� �s/• I '/ e �/�✓7‘ s'V.Pd/ lam". - 0, moo, eg,. LReutcr 5C / 2 LOUIS W,JR..INC.. i300 HEMPSTEAD TP E. 97482 1 WEST HEMPSTEAD,NY.11382 .. ... " . . -- / 'J // GO Wa :: W Z 0 W it. S <C t� " " 4, RAILING: HORIZONTAL CABLE INFILL (WITH FOOT RAIL) DWG # RAIL H-CABLE REV 1 y - ,� 36" HIGH ALUMINUM FRAME WITH FOOT RAIL DATE 11/07 — I- ® •� o° NOTE: 42" HIGH RAILING DETAIL SIMILAR WITH ADDITION OF 2 CABLES t j 0 1 ; AND REDUCTION OF POST SPACING TO MAX 5-FT. 0 >. W 1 ' Ne w e-A I L-s Z wi POST SPACING 4� Q! AX. 6 FT. FOR 36" HIGH RAILING NOTE: SEE SEPARATE "CAP RAIL" DETAIL INTERMEDIATE LMAX. 5 FT. FOR 42" HIGH RAILING .] DRAWINGS FOR CAP OPTIONS. PICKET I I i MAX. 3 IN. O.C. ` . ' MIN. 36 IN. SPACING ON i : MAX. 42 IN. CABLES. Th.- (SEE NOTE TYPICAL 1 ` , , AT TOP) C ° 1 FI DECK / FLOOR FOOT RAIL NOTE: SEE SEPARATE "POST ATTACHMENT" DETAIL SURF"CE L:111,1 DRAWINGS FOR MOUNTING OPTIONS. PICKET SPACING ill F- f=-z °C MAX. 3 FT. FOR 36" HIGH RAILING ® z p 00 z w O w m feene �.�'cNtec' u�' .l MAX. 2-1/2 FT. FOR 42" HIGH RAILING ~ / w � _ w � � w PRODUCTS 70 O2 Cw3 w —I .--1C/ ZZ O z Design Rail' —Railing Systems cc Ujwwa. zd ¢ 3 2603 Union Street cf: z p U z w U Oakland, CA 94607-2423 p j 0 p oc Uco . Ph: 800-888-2418 or 510-893-9473 m p p O o Fx: 510-893-9484, www.designrail.com 7 �1: _21 ® � Q z O o LL z Z w 25 O 4. ® E2- N CO „ � Za. 0 ¢ 0ZWF— p ` c" waoop § S8azw0D 0 Q w O O LL LL CC K CC CYC _I C�UJ cc W C,0) D llz � LL -'- CV coet _ cc } o ' WINDOWS AND DOORS WITH PRODUCT PERFORMANCE PROT�tWIN�r AT I O N Andersen°NFRC Certified Total Unit Performance Notes on the next page also apply to this page. A-Series Windows Andersen'Product Glass Type i U-Factor', SHGC2 VPAndetsen'Product Glass Type i U-Factors; SHGC2 , V(' Without Grilles 030 026 045 ,} Without Grilles 028 034 056 *' w Simulated Divided Light Grilles 031 024 040 i W Simulated Divided Light Grilles 028 031 051 ASeries; ` .' o- 1,-. Firelight`Light Guiles 030 0.24 040 A-Series , . Firelight"Light Grilles 030 031 051 Casemeld Windows,e.-z4 J Full Divided Light Grilles 0 30 0 24 0 40 Dlrect-Set Specialty 'i.:-. o z I J Full Divided Light Grilles 0 29 0 31 0 51 ARD-11--86'„-- F = Without Grilles 0.30 017 024 Windows 1N g Without Grilles 029 021 030 v� (>36sgIto4659n, ,f_ in . w Simulated Divided Light Grilles 0 30 0 15 0 22 or 3.34 m?_to 4 65 rill iw W Simulated Divided Light Grilles 0 29 0 19 0 27 w ' ` # Firelight Light Grilles 0.31 0 15 0 22 ANDN-126 � o Firelight Light Grilles 0 29 0 19 0 27 -,, '' gl 3 Full Divided Light Grilles 0.31 0 15 0 22 - 'v." Full Divided Light Grilles 0 30 0 19 0 27 ' = , Without Gnlles 028 023 051 ,,r-':,�..- ,�. Y. '^1_� ,= Without Gnlles 029 018 040 _ 111{{{{t Simulated Divided Light Grilles 029 0.17 036 - - - ' - W= Simulated Divided Light Grilles 028 021 045 3 E Firelight Light Grilles 0 30 0 17 0 36 _ ( y E F nehght light Grilles 0 28 0 21 0 45 Full Divided Light Grilles 0 30 0 17 0 36 c ''t " Full Divided Light Grilles 0 29 0 21 0 45 Without Grilles 030 026 043 - }} Without Grilles 035 031 051 Simulated Divided Light Grilles 030 023 039 ,x` , 'V w Simulated Divided Light Grilles 035 028 045 �4-Seiles , -' t„ A Firelight"tight Grilles 030 023 039 ♦A-Series , ,_, 'I,' o FolelightLight Grilles 036 028 045 Saul Set S' elal 'Awnmg WldCmvs �- f z Full Divided Light Grilles 0 30 0 23 0 39 � ty '1,_.". J Full Divided Light Grilles 0 37 0 28 0 45 AND,N-87 al Windows', - 1A- = Without Grilles 035 020 027 .i - Without Grilles 030 016 024 (>36soct°50so IL I'y e, '- W Simulated Divided Light Grilles 0 30 015 0 21 or 334 m'_to 465 rti) 't`� W Simulated Divided Light Grilles 0 35 0 18 0 24 W s ` Firelight Light Grilles 0 31 0 15 0 21 AND-N-128 ,' ; Firelight Light Grilles 0 36 0 18 0 24 - -F`.;, a 9 Full Divided Light Grilles 0 31 0 15 0 21 'i a Full Divided Light Grilles 0 37 0.18 0 24 ---'t5� Without Grilles 029 018 039 a--- Without Grilles 034 022 046 , - , 1 w' Simulated Divided tight Grilles 0 29 0 16 0 35 w e2 Simulated Divided Light Grilles 0 34 0.20 0 41 9 E Firelight Light Grilles 030 016 035 r %* Ai FinelightLight Grlles 036 020 041 Full Divided Light Gnlles 0 30 0 16 035 .1= Full Divided Light Grilles 0 36 0 20 0 41 C" :h Without Grilles 031 030 051 ' w Simulated Divided Light Grilles 0 31 0 27 0 45 'ASedes,'+", ,:"--,1 g Finelight"tight Gnlles 032 0.27 045 ,Douhle-Hung Windoivs`k,-, J Full Divided Light Grilles 0 32 0 27 0 45 ,AND-N91,,—' '' ' -1y Without Grilles 0.32 019 028 „,'4-, - Simulated Divided Light Grilles 0 32 0 17 0 25 t' '} r' 4� w Firelight Light Galles 032 017 025 a Full Divided Light Grilles 0 33 0 17 0 25 ., is a , Without Gnlles 031 020 046 _ 1'410 SimulatedDivided Light Grlles 031 018 041 Andersen'NFRC Certs d Total Unit Performance :-°'t, , gFirelight Light Grilles 032 018 041 9E enes Wind - ,,,d`p " Full Divided Light Grilles 0 32 0 18 0 41 '"� -, -...1.'-=. Without Grilles 0 29 0 31 0 53 w Simulated Divided Light Grilles 029 028 047 , ,. - - - , I ,`A.Sedes, F,u S Firelight`Light Grilles 030 0.28 047 '" _ ,Picture Windows,, :„-•( 1 Full Divided Light Grilles 0 30 0 28 0 47 Andersen Product Glass Type 1 U-Factor'1 SHGC2 i Vis AND-N-88, 1' - 1: - fl = Without Gnlles 030 019 029 _ Without Gnlles 033 031 053 W " Simulated Divided Light Grilles 0 30 017 0 25 '- .- - 1'- w Simulated Dmded Light Grilles 0 33 0 29 0 48 ' `( 3 Firelight Light Grilles 0 31 0 17 0 25 4007Serles i ,- 9 Firelight"tight Grilles 0 34 0 29 0 48 '�„i3 9 Full Divided Light Grilles 0 31 0 17 0 25 Casement Windows i Full Divided Light Grilles 0 34 0 29 048 1I f • Without Grilles 0 29 0 21 0 47 ANON-t- - -S I Without Grilles 0 33 0 20 0 29 ' 1 W' Simulated Divided Light Grilles 0 29 019 0 42 '-,€Zrt - Simulated Divided Light Grilles 0 33 0 18 0 27 I s E Firelight Light Grilles 030 0 19 0 42 y}} o”' Firelight tight Grilles 0 34 0 18 0 27 Y.( " Full Divided Light Grilles 0 30 0 19 0 42 W t Full Divided Light Grilles 0 34 0 18 0 27 r - .2'1 Without Grilles 030 031 053 161 - ' Without Grilles 033 021 048 ' w Simulated Divided Light Grilles 0 30 0 28 0 47 . '.¢i Simulated Divided Light Gnlles 0 33 0 20 0 43 A--Series , '- 1, ' A FinelighoLightGnlles 030 028 047 ?1' 3N FinelightLigtltGrlles 034 020 0.43 ',Statlonarp Transom", -z' Full Divided Light Grilles 031 028 047 Full Divided Light Grilles 033 020 043 Windows\,'.' RI c Without Grilles 030 020 029 ' - }'-1 „ Without Grilles 079 058 066 •avaN 69-' w3 Simulated Divided Light Grilles 0 30 0 18 0 26 }j} $ W Simulated Divided Light Grilles 0 79 0 53 0 60 Firelight Light Grilles 031 018 026 ,- ' 1'y ` Without Grilles 079 045 0.39 a3 ! 2 Full Divided Light Grilles 031 018 026 ..? u Simulated Divided Light Grilles 079 041 036 --- . •a- --' -ff Without Grilles 029 021 048 Without Gnlles 033 031 052 -' ;- S w,= Simulated Divided Light Gnlles 0 29 0 19 0 43 i w Simulated Divided Light Grilles 0 33 0 28 0 47 • -°i p Firelight tight Grilles 030 019 043 400 Series ( g Firelight`Light Grilles 034 028 047 - " Full Divided Light Grilles 0 30 0 19 0 43 Arming Windows I Full Divided Light Grilles 0 33 0 28 0 47 Without Grilles 030 027 045 AND r Without Grilles 034 020 029 : } - G- l W Simulated Divided Light Grilles 030 024 041 {,z Simulated Divided Light Grilles 034 018 026 ASedes ,' ,, , o Finelight`Light Grilles 0 30 0 24 0 41 ',',-15.1 3 r, Firelight Light Grilles 0 34 0 18 0 26 eerlttng Transom,- zi Full Divided Light Grilles 0 30 0 24 0 41 - 1w; Full Divided Light Grilles 0 34 018 0 26 Windows ,[ 1 o Without Grilles 0 30 017 0 25 e' Without Grilles 0 33 0 21 0 47 waNao jw1 ' Simulated Divided Light Grilles 030 015 022 �t WC Simulated Divided tight Grilles 033 019 042 iii o Firelight Light Gnlles 031 015 022 4 J E Firelight Light Grilles 033 019 042 ' ( j Full Divided Light Gnlles 0 31 0 15 0 22 1, m • Full Divided Light Grilles 0 33 0 19 0 42 - ' =i Without Grilles 0 29 0 18 0 41 g,. ! 0 a Without Grilles 0 83 0 57 0 65 - 4 i W 0 Simulated Divided tight Grilles 0 29 0 17 0 37 $ U Simulated Divided Light Grilles 0 83 0 52 0 59 c # 9N Firelight Light Gnlles 030 017 037 t E - Without Gnlles 083 044 039 j Full Divided Light Grilles 0 30 0 17 0 37 ' o Simulated Divided Light Grilles 0 83 0 40 0 35 continued on next page 2014 Coastal Product Guide Page 1 of 4 • 1WINDOWS•DOORS 400 SERIES Andersen® A-SERIES Andersen NFRC Certifie -'tai Unit Performance(continued) 400 Series Windows i Andersen•Product Glass Type i U-Factor's SHGC2 ; VT3 Andersen•Product Glass Type i U-Factor'i SHGC2 i Vf Without Grilles 026 034 057 - Without Grilles 0.26 034 057 - , "r- w Simulated Divided Light Grilles 0 26 0 31 0 51 - ,; i- w Simulated Dwided Light Grilles 0 26 0 31 0 51 400 Sedes. " e Firelight`Light Grilles 0.26 0 31 0 51 400 Seder• •` e 3 Firelight`light Grilles 0 26 0 31 0 51 Casement/Awning r i Full Divided Light Grilles 0 27 0 31 0 51 Hay Circle- § Full Divided Light Grilles 0 27 0 31 0 51 ,.Plcture,Wlndews _' i! Casemen Awnin r Without Grilles 026 021 032 Oval g' ,1, Without Grilles 026 021 032 ''AND-N-54 - r. W Circle&Oval Windows',1 W ,r"--; = Simulated Divided Light Grilles 0 26 0 19 0 28 '; •.0154• , ;,- = Simulated Divided Light Grilles 0 26 0 19 0 28 "Nt 3,7 Firelight Light Grilles 0 26 0 19 0 28 y o" Flnelight Light Grilles 0 26 0 19 0.28 J _ i w) Full Divided Light Grilles 0 27 0 19 0 28 .wFull Divided Light Grilles 0 27 0 19 0 28 f: - ,- ;,,T.1Without Grilles 025 023 051 .:1 ." *'—i,..2,11 Without Grilles 025 023 051 ,'la] w Simulated Divided Light Grilles 025 021 046 la w, Simulated Divided Light Grilles 025 021 046 1 e Firelight Light Grilles 025 021 046 , e FlnelightLight Grilles 025 021 046 ,.,',l• S. fO Full Divided Light Grilles 0 26 0 21 0 46 ' ,i., " Full Divided Light Grilles 0 26 0 21 0 46 - v`I a Without Grilles 082 059 071 c' Without Grilles 082 059 071 '.r , -4., *i''I $ u Simulated Divided Light Grilles 0 82 0 53 064 - ,.')v 'S u Simulated Divided Light Grilles 0 82 0 53 064 < •� °`� i ax Without Grilles 082 048 036 I Without Grilles 082 048 036 , -r " 4-!'.::;',i,1 ' = Simulated Divided Light Grilles 0 82 0 43 0 32 ,_ -,_ - ;t I a Simulated Divided Light Grilles 0 82 0 43 0 32 :4. _' ; .,'': 3 Without Grilles 0 34 0 31 0 53 • fix Without Grilles 0 27 0 33 0 56 l�•" a,�� Simulated Divided Light Grilles 0.34 0 28 0 47 1 W Simulated Divided Light Grilles 0 27 0 30 0 50 496.Settei'•,.•4.",,!,..' r '4 i' • o Firelight'Light Grilles 036 028 047 '400seder'. o Firelight-Light Grilles 028 030 050 nn wash _ ;-` $$', ,Hai!Cimle=Double':' t 4; Full Divided Light Grilles 0 35 0 28 0 47 ij J Full Divided Light Grilles 0 28 0 30 0 50 t.DoeWalking, '- ;1. HungKRndows;'- .1 ] Window's,. "; Without Grilles 035 020 029 _ .,., tJ Without Grilles 027 021 031 'ANO{J-Z4, `i,z, w= Simulated Divided Light Grilles 0 35 0 18 0 26 'AND,7' ' I'Z9 w= Simulated Divided Light Grilles 0 27 0,19 0 28 y 9" Flnelight Light Grilles 0 36 0 18 0 26 j+.rt',;; „� } o"' Firelight Light Grilles 0 28 019 0 28 Full Divided Light Guiles 035 0 18 0 26 ; - «i y ,Sir � P. , FuIlDmdedLightGnlles 028_ __0.19 028 t''-•''... JR] Without Gnlles _034 021 047 - } Without Gnlles 0.26 022 050 _ ,..Ci w' Simulated Divided Light Grilles 0 34 0 19 0 42 a' '. , ,a't 7,,, Simulated Divided Light Grilles 0 26 0 20 0 45 +'v.,4,',4,g+ E Firelight Light Grilles 0 35 0 19 0 42 {'t�- o Firelight Light Grilles 0 27 0 20 0 45 } Full Divided Light Grilles 0.35 0 19 0 42 `. " Full Divided Light Grilles 0 27 0 20 0 45 _ Without Guiles 0 81 0 57 0 65 •v .r g Without Gnlles 0 81 0 58 0 70 -t,.,, - `•` S i o Simulated Divided Light Grilles n/a n/a n/a ,, Simulated Divided Light Gnlles n/a n/a n/a '1',..--;.-,-s,' "` " ix l i Without Gnlles 081 044 039 l / i>1 = Without Gnlles 081 047 036 ':<: : ; ', '*,t'"`;,, . i = Simulated Divided Light Gnlles n/a n/a n/a ., . ? '4 _„._., I .. Simulated Divided Light Grilles n/a n/a n/a r,_, , €, '4., - '. s Without Gnlles 0.26 0 31 0 54 ',+., ; -:;;.St;. Without Gnlles 0 27 0 33 0 56 .i „3. ,' •y`,, Simulated Divided Light Grilles 0 26 0 28 0.48 �,' �' w Simulated Divided Light Grilles 0 27 0 30 0 50 -400'Serles ''-„ o Finelight`Light Gnlles 0 26 0 28 0 48 400 Series _ F" 3 Firelight'Light Grilles 0 29 0 30 0 50 1,411t-Wash Transom,' J Full Divided Light Grilles 0 27 0 28 0 48 'A�!Windows ••' -1 ' Full Divided Light Grilles 0 29 030 0.50 Wllldows„�,2. 'w_!. ;d AND-N-1S-.•• AND-N.7,6 4 Without Grilles 027 019 030 , ;� Without Gnlles 028 020 030 4.�z w= Simulated Divided Light Grilles 0 27 0 17 0 26 ,r r ,L w= Simulated Divided Light Gnlles 0 28 0 18 0 27 "� �" Firelight Light Gnlles 027 017 026 I- .s7. o" Firelight Light Gnlles 029 018 027 t^•tW Full Divided Light Grilles 0 28 0 17 0 26 _ .'„01 J Full Divided Light Gnlles 0.29 0 18 0 27 s + . Without Grilles 026 021 049 raw° , Without Grilles 027 023 050 ai w 0 Simulated Divided Light Grilles 0 26 0 19 0 44 ' ' g w Simulated Divided Light Grilles 0 27 0 20 0 45 '- 1 9 o Firelight Light Gnlles 0 26 0 19 0 44 -s.- a E Finehght Light Gnlles 0 28 0 20 0.45 } " Full Divided Light Grilles 0 27 0 19 0 44 ' �,' J" Full Divided Light Gnlles 0 28 0 20 0 45 '1 r • �.J,fir , •, Without Grilles 0 79 0 58 0 67 - „ Without Grilles 0 83 0 59 0.71 ' - '' P. . Simulated Divided Light Grilles 0 79 0 52 0 60 ," . t $ o Simulated Divided Light Grilles 0 83 0 53 064 ''> ' 'I r ` a Without Grilles 079 046 034 - _ .,.}r":4 Without Grilles 083 048 036 .4:4-.``.ti," - ,• ;(-. u Simulated Divided Light Grilles 0 79 0 42 0 31 - ;,.., a Simulated Divided Light Grilles 083 0 43 0 32 1 Without Grilles 032 033 055 Without Grilles 030 033 056 ..'4,'i'� ' ' f v Simulated Divided Light Grilles 032 029 049 '„-, ,...F' ,;; Simulated Divided Light Grilles 030 030 050 40Seises ;' .�' 9 Firelight`tight Gnlles 0 33 0 29 0 49 400 Seises - ,-- 9 Firelight`Light Gnlles 0.32 0 30 0 50 TIH•Wash!eter°:. a(' W S ilii loo Windows!' - Dividedi Without Grilles 031 020 030 ;AND N-27, y`z w= Simulated Divided Light Grilles 0 32 0 18 0 27 ,' z1{{ ;15 = Simulated Divided Light Grilles 0 31 0 18 0 27 - )H �`7' Firelight Light Grilles 0 34 0 18 0 27 _ 'yj s" Firelight Light Grilles 032 0 18 0 27 - ` ,q,'-'-,, Full Divided Light Grilles 0 32 0 18 0 27 !al Fll Divided Light Grilles 0 32 0 18 0 27 Without Grilles 031 022 049 • . 4f1 , Without Gnlles 030 023 050 ' - fa i w Simulated Divided Light Grilles 0 31 0 20 0 44 t a w' Simulated Divided Light Gnlles 0 30 0 21 0 45 i 9 Firelight Light Gnlles 033 020 044 - )-, S E Firelight Light Gnlles 031 021 045 -• # " Full Divided tight Grilles 0 32 0 20 0 44 - ,f Full Divided Light Gnlles 0 31 0 21 0 45 f, Without Grilles n/a n/a n/a 1 .a „ Without Grilles 0 85 0 59 0 71 - ' to ; $ v Simulated Divided Light Grilles n/a n/a n/a - $ o Simulated Divided Light Grilles 0 85 0 54 064 1-., - f _ Without Grilles n/a n/a n/a .1'; Without Grilles 0 85 0 48 0 36 , , [ ct Simulated Divided Light Grilles n/a n/a n/a , . Simulated Divided Light Gnlles 085 043 032 continued on next page ••Low-E4'SmartSun","Low-E4•"and"Low-E4'Sun"are Andersen trademarks for"Low-E"glass 1)U-Factor defines the amount of heat loss through the total unit in BTU/hr/ft'°F The lower the value,the less heat is lost through the entire product Window values represent non-tempered glass Use of tempered glass can increase U-Factor ratings See andersenwindows com/nfrc for specific performance values Door values represent tempered glass 2)Solar Heat Gain Coefficient(SHGC)defines the fraction of solar radiation admitted through the glass both directly transmitted and absorbed and subsequently released inward The lower the value,the less heat is transmitted through the product 3)Visible Transmittance(VT)measures how much light comes through a product(glass and frame)The higher the value,from 0 to 1,the more daylight the product lets in over the product's total unit area Visible Transmittance is measured over the 380 to 760 nanometer portion of the solar spectrum •NFRC ratings are based on modeling by a third party agency as validated by an independent test lab in compliance with NFRC program and procedural requirements •This data is accurate as of October,2013 Due to ongoing product changes,updated test results,or new industry standards or requirements,this data may change over time Ratings are for sizes specified by NFRC for testing and certification Ratings may vary depending on use of tempered glass,different grille options,glass for high altitudes,etc 2014 Coastal Product Guide Page 2 of 4 St�+ WIND1'OWS AND DOORS WITH PRODUCT PERFORMANCE ® 11C;� PROTECTION Andersen*NFRC Certified Total Unit Performance(continued) 400 Series Windows i .. Andersen'Product Glass Type U-Factor'. SHGC' ? VP Andersea•Product Glass Type ;U-Factor'; SHGC' • VP Without Grilles 0 27 0 33 0 56 -• , Without Grilles 0 31 0 25 0 42 ` w Simulated Divided Light Grilles 0 27 0 30 0 50 w Simulated Divided Light Grilles 0 31 0 23 0 38 ,,4q0 Series' 3 Finelight Light Grilles 0 28 0 30 0 50 A-Series o Finelight'Light Grilles 0.32 0 23 0 38 Fleolframa.Windows Full Divided Light Grilles 0 28 0 30 0 50 'FrenchW0od`•Patio ' J Full Divided Light Grilles 0 32 0 23 0 38 Anu•rb-11.17 Door Sash-Set , Without Gnlles 027 020 030 t Without Grilles 031 016 023 Transoms&Sidelight; • z i w c Simulated Divided Light Grilles 0 27 0 18 0 27Tmgsoms ' 4.g Simulated Divided Light Grilles 0 31 0 14 0 21 a' o" Finelight Light Grilles 028 018 027 AND-4 SS .y; O. Finelight Light Grilles 032 014 021 w: J Full Divided Light Grilles 028 018 027 'ku Full Divided Light Grilles 032 014 021 „Ii' ithout Grilles 026 022 050 . '- i Without Gnlles 031 017 038 a' W v Simulated Divided Light Grilles 0 26 0 20 0 45 _, ,4 w Simulated Divided Light Grilles 0 31 0 16 0 34 .' - - - ..' g. Finelight Light Gnlles 0 27 0 20 0 45 '''' E Finelight Light Grilles 0 32 0 16 0 34 • . J” _ Full Divided Light Grilles 027 020 045 - Full Divided Light Grilles 031 016 034 ' Without Grilles 0 82 0 59 0 71 • _ - without Grilles 0 70 0 42 0 49 i 5 u Simulated Divided Light Gnlles 0 82 0 53 0 63 $ Simulated Divided Light Grilles 0 70 0 38 044 I c Without Gnlles 082 048 036 - '' ' i ` ¢ Without Grilles 070 031 025 1 0 Simulated Divided Light Grilles 082 043 032 - 0 Simulated Divided Light Grilles 0.70 028 022 Without Grilles 030 033 057 w SimulatedDividedLightGrilles 030 030 051 A•Sedes `1 J Finelight'Light Grilles 0 30 0 30 0 51 Andersen°NFRC Certified Total Unit Performance FreOchwaod'PaUo ., , Full Divided Light Grilles 031 030 051 A-Series Patio Doors Doer Direct-Set- • - i Without Gnlles 030 0 2 031 Transoms&Sidelight; z • . w Simulated Divided Light Grilles 0 30 0 19 0 28 Transoms •Q, 3 i., -- pNb.Ngg .3 Finelight Light Gnlles 031 019 028 , ,wj Full Divided Light Grilles 0 31 0 19 0 28 Ariderseti'Product" Glass Type i U-Factor'l SHGC' I VP lf7 Without Grilles 0 29 0 23 0 51 Without Grilles 032 026 044 , ,6( wvs Simulated Divided Light Grilles 029 021 046 • w Simulated Divided Light Grilles 032 023 038 --r 3E Finelight Light Grilles 030 021 046 •A-Series '- ' 1 o Finelight"Light Grilles 0 33 0 23 0 38 " Full Divided Light Grilles 0 30 0 21 0 46 ''Frenchwood'.Gliding ( J Full Divided Light Grilles 0 33 0 23 0 38 - sl g Without Grilles 0 84 0 58 0 69 Patio Doors ' Without Grilles 0 32 0 16 0 24 ` 'i '$ L• Simulated Divided Light Grilles 0 84 0 53 063 'ANON-99 - I • - ''ter Simulated Divided Light Grilles 032 015 021 _ Without Grilles 084 043 035 ' N+ o" Finelight Light Grilles 034 015 021 -- . J Simulated Divided Light Grilles 084 039 031 J w; Full Divided Light Grilles 033 015 021 Without Gnlles 031 023 037 ' m • Without Grilles 0 31 0 18 0 40 , w Simulated Divided Light Gnlles 0 31 0 20 0 33 a I w, Simulated Divided Light Gnlles 0 31 0 16 0 34 .-hSerles _ 9 Finelight"Light Gnlles 0 33 0 20 0 33 '1,r, FreechYmad`Patio j Full Divided Light Gnlles 0 32 0 20 0 33 - i Finelight Light Gnlles 033 016 034 Door Sidelights • , , I Full Divided Light Gnlles 0 32 0 16 0 34 ANS_ Without Gnlles 0 32 0 14 0 20 „ 2 Without Gnlles 0 70 0 46 0 54 - a w c Simulated Divided Light Grilles 0 32 0 13 0 18 ? " $ e, SmartSun' 070 040 046 ," 3Finelight Light Grilles 033 013 0 18 Without Grilles 0 70 0 34 0 27 �' Full Divided Light Grilles 0 32 0 13 0 18 • 0 Simulated Divided Light Grilles 0 70 0 29 0 23 - Without Gnlles 0 31 0 16 0 34 _ , .__i Without Grilles 032 024 040 ? ' o'"c.i u,, Simulated Divided Light Grilles 031 014 030 ` w Simulated Divided Light Gnlles 0 32 0 21 0 34 Yt 2 h Fnelight Light Gnlles 0 32 0 14 0 30 `A-Series i o Finelight Light Gnlles 0 33 0 21 0 34 _ Full Divided Light Grilles 0 32 014 0 30 >Frenchweod'hinged ', -' Full Divided Light Grilles 033 021 034 Without Grilles 065 039 046 Inswing Patio Doors , 5 . Simulated Divided Light Gnlles n a n a n a AND-N-92 , Without Grilles 0 32 0 15 0 22 •�, I / / ! . , w- •tig Simulated Divided Light Gnlles 032 0 13 0 19 . • • i Without Grilles 0 65 0 32 0 23 a4 J'n Finelight Light Grilles 0 34 0 13 0 19 .- � � � Simulated Divided Light Gnlles n/a n/a n/a �: Full Divided Light Gnlles 033 013 019 ` cam.. . '= Without Grilles 0 31 0 16 0 36 ac,,, 4,T, Simulated Divided Light Grilles 0 31 0 14 0 31 —, 51Finelight Light Grilles 033 014 031 E " Full Divided Light Grilles 0 32 0 14 0 31 ,- Without Grilles 067 041 049 $ r Simulated Divided Light Gnlles n/a n/a n/a , , g g Without Gnlles 067 034 025 0 Simulated Divided Light Grilles n/a n/a n/a Without Grilles 0 31 0 24 0 40 — Simulated Divided Light Gnlles 0 31 0 21 0 34 A-Series '- . , o Finelight"Light Grilles 033 021 034 ?renamed'hinged , J Full Divided Light Grilles 0 32 0 21 0 34 •"Low-E41 SmartSun"","Low-E4"'and"Low-14`Sun"are Andersen trademarks for"Low-E"glass Outswing Patle Doors 1)U-Factor defines the amount of heat loss through the total unit in BTU/hr/ft'•F The lower the value,the ANON-93" ' Without Grilles 0 32 0 15 0 22 ` - z' f Simulated Divided Light Grilles 032 013 0 19 less heat is lost through the entire product Window values represent on-tempered glass Use of tempered #/7, glass can increase U-Factor ratings See andersenwmdows com/nfrc for specific performance values Door . " 3 Finelight Light Grilles 033 013 0 19 values represent tempered glass 2)Solar Heat Gain Coefficient(SHGC)defines the fraction of solar w Full Divided tight Gnlles 0 33 0 13 0 19 radiation admitted through the glass both directly transmitted and absorbed and subsequently released - cc • Without Grilles 0 31 0 17 0 36 inward The lower the value,the less heat is transmitted through the product 3)Visible Transmittance(VT) aI w' Simulated Divided Light Grilles 0 31 0 15 0 31 measures how much light comes through a product(glass and frame)The higher the value,from 0 to 1,the g omore daylight the product lets in over the product's total unit area Visible Transmittance is measured over rn Finelight Light Grilles 0 33 0 15 0 31 the 380 to 760 nanometer portion of the solar spectrum Full Divided Light Grilles 032 0 15 031 •NFRC ratings are based on modeling by a third party agency as validated by an independent test lab in • Without Grilles 0 67 0 42 049 compliance with NFRC program and procedural requirements 5 tI Simulated Divided Light Grilles n/a n/a n/a •This data is accurate as of October,2013 Due to ongoing product changes,updated test results,or new ' ` Without Grilles 067 034 025 industry standards or requirements,this data may change over time Ratings are for sizes specified by NFRC Simulated Divided Light Grilles n/a n/a n/a for testing and certification Ratings may vary depending on use of tempered glass,different grille options, glass for high altitudes,etc 2014 Coastal Product Guide Page 3 of 4 WINDOWS•DOORS 400 SERIES . , Andersen. A-SERIES About the NFRC About the Label The National Fenestration Rating Council(NFRC)is a nonpartisan coalition of professionals whose Look for this certification label on every window and patio door you purpose is to provide fair,accurate and credible energy performance ratings for fenestration products. buy.The NFRC section was designed by the National Fenestration NFRC's membership includes manufacturers,suppliers,designers,specifiers,utility companies, Rating Council to provide accurate information that helps you government agencies and other building industry representatives. promote the energy efficiency of the homes you build.These ratings allow you-and your customers-to measure and compare the Andersen Corporation is a founding member of the NFRC and continues to support its work by providing energy performance of similar products.If the product does not fair,accurate and credible energy performance ratings to consumers and the building industry.If you have this label,the NFRC has not venfied its claims. have any questions about the NFRC,its program or energy performance ratings,wnte them at NFRC, 6305 Ivy Lane,Suite 140,Greenbelt,MD 20770,Tel:(301)589-1776 Website:www.nfrc.org Do not remove until final code Inspection.Save label for future reference 1 8 Qualified lur dehnghred area, Energy Rating(ER)represents"Energy Mond am exiuences pour les regions Minutes. Rating"and is a rating used in Canada • Canada • :1,`� A.1--,...:-"..., 1 NOD 387-2000 :f. -i i • y for product companson purposes(the `� cn of enoryyetnr8oae t l'.,4 ��: "" `� ', o �a ca .,.... higherthe ER number,the more energy ¢ w jd_ ENERGY STAR Climate Zone Map Er;T t_ .t saved dunng the heating season). < 4a i ._ ' • is based on U-factor and solar heat E ENERGY STAR VJ r .: - W a us.aEu. `tea gain coefficientcritenafor specific ° Ism -,`D re ❑=Ouallrled/Admiss)bin ENERGY STAR climate zones within the WINan WS•DDO RS 1 United States and Canada.The shading NFRC `� AndersenD,�s of the map shows which climate zone(s):' Casement Picture Window a particular product and glass type is AND-N-54 01190-00001 National Fenestration Vinyl-Clad wood Frame,Dual-Pane Low-E Impact ENERGY STAR qualified in. Ratng Councga Resistant Glazing with Argon CERTIFIED ProductType. Fixed ENERGY PERFORMANCE RATINGS U-Factor indicates how well a product U•Factor Solar Heat Gain Coefficient Solar Heat Gain Coefficient prevents heat from escaping(the lower •0.26 I 1.5 0■34 •-- measures how well a product blocks the number,the better). (U.S.4 P) (PAetricIS heat caused by sunlight(the lower ADDITIONAL PERFORMANCE RATINGS the number,the more it will help Visible Transmittance refers to how Visible Transmittance reduce the use of air conditioning much visible light comes through a • 0.57 and as a result reduce electncal bills product(the closer to 1.0,the more Maindasturerslipulates Mat these ratings°Worm to appfleable tiNIC premiums tar detenmaing whole product perfor°ance.NNic ratings are datermilmd Int anna mot enex rai=Wound a specific product Ra NFRC and energy use). light is transmitted). doesjota,reeotaztaigudoetirgmirant Ile su'aIM M any product l.aped.c use Conan WDMA Hallmark Certification venfies lb WDMA the performance ratings of this product were WINDOW AND DOOR HALLMARK MANUFACTURERS ASSOCIATION CERTIFIED tested by a third party testing laboratory. ""r00060m CCL#129-11-774 ANDERSEN CORPORATION 400 SERIES CASEMENT PICTURE WINDOW Manufacturer Stipulates Conformance to the following standards STANDARD RATING Test Standards - - - MMIy1VpE4yRe 101/iS2/644008 P.5O/65 DASSIGFG5ODSRErosno°e s,' 0-- Performance Grade(PG)and ,W{505"ETE61ED so-,rz MMR/000W56e101/i6M 1/6440DP•60/e5 Design Pressure(DP)Ratings wmmme a Mai@ Level Florida Product Approval acne E16a60166199601 Cycle Nsme.50/E5 Number,Miami-Dade County ♦ FL 1092 I Glazing 4 Omen AN outer/11 7mm LG(4 7mm AN/4 7mm AN)inner • Impact-Resistant Notice of Acceptance(NOA) Laminator cardinal Mtelayer Dupont Owno les9a(Oe90M) P Number or Texas Department SE44 1st,rdo 0,or:oD`er. Complies with HUD UM Bulletin 111 Glass Construction 4' standards jamming of Insurance(TDI)Number metalsI lend mean Stair In the lame and �x4O °mate00lS 0E141\@ pacpap)ng•aod consumer education mamas 701608063PRU-1 Meets or exceeds M E C,C E C 8 I EC C Nr Indltration Requirements WDMA Hallmark Cartincati°n Program •NFRC ratings are based on modeling by a third party agency as validated by an independent test lab in compliance with NFRC program and procedural requirements 2014 Coastal Product Guide Page 4 of 4 , 04-08-14; 11 :36PM; • # 1/ 7 • From the desk of:. LAURIE COLLETTI Windowrama Sales Administrator 71 Heartland Blvd Edgewood, NY 4 717 PHONE: (631) 667-2555 east. 2123 FAX: 631-667-3366 - Coll'ettiL@windowrama°oom ATTN: Bi DATE: + L STJBJ: # F PADES list.COVER '7. ' - - r• - - 41 V • eRvi _Tirn • • vm - isryPo. • • a 1 ! I I I L00/LOQ2, 9l :Eo vin/Eo/to 04-08-14; 11 :36PM; # 2/ 7 • Terms and Conditions of Safe DEPOSITS •uteri,Marchuftelae.Common Aw enblle%, Homveerndrol 26%Depcelt Required. end Common•Nan 5t set Merchandlao: ContrromrDiaireon Mambos:No Dapo&itFtequlred •Special Older,-peeler Aeeembller' Homeowners.50%Depcoh Required,Caen er Apprhwd Cheek, IN Custom Merehnndiee: Cehlfedar Division Mombora'3S%Deposit Recurred PAYMENT, •Full payment duo on ornery oft0ERS •Cash,Maatawcerd,Wan,Dl•oovar,WindovRsma Credit Cert •Homeowner end contractor Divlsion Membero approved checks re Seno3 with twolonns of ID(Crewe Oconee and major credit card) • •All checks for orders touring mer$5000 must be ceNbod, NOTE:N.S.F.ehsnka will be e,sassed a$20,00 hardline Mures/ ' •Sayer roulna lute to all merchandise erne It le paid for.In rull.Seiler/Moil hive the right to reposes's*such merchandise In the event of 0 dereuu In payment or non-payment,In eMerdehCe With thane tonin of sale I •Purchaser accepts primary liability for the payment of all nmohsndlse shipped anmot biped habon and wotv,s the right to ueo an a defense,ageless peymont the • obllgaton of a third p■dy to pey purohaser for said htomrlale, •Seder shell not be reeponelbre to purctraserfor marehandlse erdered that Is not available through Setter&,gooier spume&of supply. •NC solos quotstlon an austom or■peclal order merahandla*shell he teodgnlzed until the order le approved by management,$riper shell notify Purchaser of any change In push prteinp end,thereafter ohould Wier change pricing.PurChadet obeli have the right lo cancel the order within 72 Raure of receiving such revised ' pricing. •Belling Mee ahown on Inveluee ora voila If entire mete Is placed within 30 day!of the;Mal order dale ehown on the Involce, j DELNQRY r Defiverlee are sidewalk arty. , •bell'efy dslaa and times are fumlehed merely as a general guide;lee under no cuhurnatehgae are delivery dates or tense guarantaer7 -Saner&hall not be ro&ponalN,foe the,allure to perform fbreny re&sen other then grope hegdgenma •RodaGvon of rparcheeelee duo to cuotetnaf cause will be assessed a redele,erycharge,11175.0D mtnlmum -should customer opt(or an unattended delbrerN 0uobfmsr takes TO responsibility for ell merehartdice uhaaended,WlndowReme reserves the right lo het omen*the delivery ohould the delver datermine that The drab alb dam riot meet WindmvRams*creole far smurity,dhmlpe protection,ere.Itthla eltuetlon occurs,010 141 en a tedellvery charge, •nelWery in gaeee0 of 26/eh melee of R WlndawReme location will be mimed addinvrati delivery emerges. •Awembllas coquina a vhlnlmum of a working days as deliver,common nematoaked moM4dndlse tegtlires a minimum or 7 to 10 working deye re deliver and speclal or euatom merchandise inquires a minitnwp al 4 to 18 Weebe to delirtes. ACCEPTANCE upon faoelpt of msrobendiee et dshvery,ouclomeraeknowiedga■byslpngture e000plable condition and count of merchandise And ohould rote any diearepenolee , on invoice ot erne of iul4ep pradeanion,Motassaptance of merchandlae,Winee,Ramo shell not On hold responsible for damages,broken ellen erehonege, uneees MCP noted atrima of delivery, , RETURNS OR FAILURE TO TAKE FINAL,DeLNERY(CANcI LLATIohts) ' - •Stock Meryhandlrof--- - - f=ull Credit if merghardiee is in complete original packaging,undamaged,not Installed,returned withal 30 days and M04otnwhled by proof of punches., •Damaged.painted.emitted,a tered ND RETURNU On REFUNDS I' • at Instilled Memmbendiem •Special Orden,Steele!Areembllee,Custom Moretendieet NO RETURNS OR REFUNDS;further.aUdh malohendlea le epgolnllymenufamufod to Buyer's ', spooficatians.kis urmferetaad end agreed thpl;In Pm Vont of Buyer's Tenure orrefusal to accept MOO merehendise,no ready market for resale Is avelteblo re the Smear Into.event of Guyer's!allure or retool et Wm delivery of me%hmerehendlee within 30 days atter nodlieodon of evenabillry,ecce being of the essence. Buyer shell be deemed In defaulter rale agreement In each event Sallee Menne of damages cacti be lire full contract peen of the merchandise uplifter with ieeklemal damages Including,bet not general to,charges incurred be seller In etepaing delivery and In storing the Merchandise actor pew*gefoult,less any depoene or payments made by Buyargd aaradnt of bre contract price, , •Cash refund%Wirt be Issued at the store asp to$20.00.Credknard toftthdswilf be issued by the store.Cash refuhdd lit ea uses 41520,W era abject to main ogee •• approve:tied will be Retied bychookwithm a5 days of return of goods,All Mune are&object to inspection prior Co refund or exchange end mull e.%wanpenled by receipt • •Cfatflhmost he used(or refunds requeaiaei)within 18 month;nem the date*credit Is reseed,or they shall Re desired null and void A'RORNZY'S MS In the event of a default by Buyer In too payment of the purchase price or of any ether ran and eondrtlon of this agreemeuton Buyer%peete be performed,eviler shall be entitled to reasonable ottofney/a fame ohdfdt co4ogign fees!muffed In the coil lite edloctIon of any mime doe hereunder or In the enforcement el dee agfaonrent • Whether ult Is nod or net All tfenaesiona hied bo governed by the taws or the stere cf Now York, WARRANTIES VelndowRams makes en exprrs.d or Imclied wProorme 4n arty meranendhe add,Material pfd by WlndoaRame come only with the Warranty of their menufacturer,eeplee of the wdoue manrtecturore Worrenulae an•avallebfe upon request, Manufaeturee emfrennen will only be effective when the mamhand4e has bun Paid for peer to dee defect arising,PurchaserPurchaser agrees to hila Wlndewleome ' hamtbea at emona prenoodirgs uta pdpatlen ailalhd auearcharges brouphtageIneteny Mandfectgrerwttgso product rot Bold by WlndowReme,WindewRema may at ire discretion repairer replace any defective Pante product without incurring any futdler llebillty therertre,Under no cirwrnstencaswill WlndowRama ho roapWtgale roreenwqusndd damages,delay Greene or any otharaglleoh171atrne Maluding%ledms for labor caste. INQUIRIES All Inqutdeeahuuld be made at too dlbrah If fddhera-,siaTance Is required.Amite nontote51.86772555.Monday tem Friday, SAM to SPIV and oak rte Customer Service ORDER# 93340 - 00 Sigrlod Specification Doc. Aef# i sold To , LBE T CONT Shlp To l' BEAVERDAM RD 569'35 RT 49 LI.PDRT, NY 11713 GREENPDRT, NY 11944 l' SALES AMT $19,342.64 DEPOSIT TAKEN... $.00 • SALES TAX,.. 01,071.32 DEL CHARGE $35.00 BALANCE DUE $21,040.96 RESTOCKING/MISC CHG. $.00 , ORDER TOTAL $23..048.96 • This order is for Custom Merchandise t I HAVE READ AND AGREE.TO WINDOINRAMA'S TERMS AND CONDITIONS OF SALE. •• ORDER IS CORRECT AS DESCRIBED ON SIGNED SPECIFICATION DOCUMENT. • NO EXCHANGES, REFUNDS. OR CANCELLATIONS PERMITTED FOR CUSTOM MERCHANDISE. Customer signature: Print customer Name: • 2x.00/Zoon XV. 91. :SO 171.0Z/C0/170 ' Andersen Andersen Windows-Abbreviated Quote Report R! 4 T� Project Name: CARUSOUTHOLD-EZRA FIFE Q Quote#: 267505 Print Date: 134/03/2014 Quote Date: 03/1412614 iQ Version: 14.0 1i bth. Dealer: Customer: Billing Address: • Phone: Fax: Sales Rep: Laurie Colletti Contact: rn Created By: Trade 10: Promotion Code: Item - Qty Item Size(Operation) Location Unit Price Ext.Price 0001 4 CW25(LR) S 734.72 $ 2938.88 RO Size=4'9"W x 5'0 318"H Unit Size=4'8f/2"Wx4'117J8"Fi E- Unit,White/Clear Pine,LR Handing,(All Sash)High Performance Low-f4 Glass(Includes 0 Me'Factory Applied Clear Pine Complete Unit Extension a Jambs) Insect Screen,White Hardware Pack.PSC,Contemporary Folding-White Zone:North-Central U-Factor 0.29, SHGC:0.32, ENERGY STARK Qualified:Yes QUd2 4 CW24(LR} $ 646.64 $ 2586.56 ROSize=4'S"Wx4'O112"H Unit Size=4'8 112"W x 0"H Unit,White/Clear Pine,LR Handing,(All Sash)High Performance Low-E4 Glass(Includes i3 9116"Factory Applied Clear Pine Complete Und Extension Jambs) Insect Screen,White Henfwa&e Pack,PSC,Contemporary Folding-While Zone:North-Centre U-Factor.0.29, SHGC:0.32, ENERGY STAT lQualirred:Yes o) N Quote 1k 267505 Print Dale: 04/0312014 Page 1 Of 6 10 Version: 14.0 *k = w J P•-• Item Qty Item Size(Operation) Location UnitPrtoe Ext.Price 0003 2 CW/4(L) $ 352.00 $ 704.00 ROSize=2'47+8"Wx4'0112"H Unit Size=2'4 318"W x4'0"H f-EMS � Uni1,White/Clear Pine,L Handing,Eligh Performance Low-E4 Glass(Includes 8 9116'Factor/Applied Clear Pine Complete Unit Extension Jambs} Insect Screen,While Hardware Pack,PSC,Conlemporary Folding-White Zone:North-Central w U-Factor 029. SHG 0,32, ENERGY STAR&Oualillee:Yes t °' -Q/ viiewec) • 0044 1 CW14(11} $ 352.00 $ 352.00 RO Size=2'4 718"W x 4'0112"H Unit Size-2'4 318"W x4'0"H i-k` Unit,WhitelClear Pine,R Handing,High Performance Low-E4 Glass(Includes 6 5116'Factory Applied Clear Pine Complete Unit Extension Jambs) Insect Screen,White Hardware Pack,PSC,Contemporary Folding-White Zorn:North-Central U-Factor.0.20. SHGC:0.32, ENERGY STARE>Qualified:Yes Ui�ewecP v-ef _cy /]0 f f (1005 1 P4040(F) $ 392.00 $ 392.00 RO Size=4'0 1/2"W x4'0112"H UnitSize=4'0"Wx4'0"14 Unit,White/Clear Pine,High Performance Law-E4 Giese{Includes Q 9116"Factory Applied Clear Pine Complete Unit Extension Jambs) Zone:North-Cenhal U-Factor 027. SHGC:0.34, ENERGY STAR@ Qualif ed:Yes L m 0 N P7 Quote#; 267505 Print bate: 04/03/2014 Page 2 Of 6 10 Version: 14.0 r x* t � • r- Item Oty (tem Size(Operation) Location Unit Price Ext Price o 0 i0006 1 CW35(LSR) $ 858.08 1 85a.0o3 Q a ;ROSize=7'1118"Wx5'0313"H Unit Size=T0518"Wx4'11718"H ro El w PHI Unit,White/Clear Pine,LSR banding, (All Sash)High Performance Low-E4 Glass • Insect Screen,White - Hardware Pack,PSC,Contemporary Folding-White Zone:North-Central co U-Factor.0.29, SHGC:0,32, ENERGY STAR&Quaffed:Yes 0007 1 CW235(LR) S 592,88 $ 892,86 ROSize=4'9"Wx3`53lg"H Unit Size=4'8in"Wx3'413116"H d Unit,White/Clear Pine,LR Handing,(All Sash)High Performance Low-E4 Glass(Includes 6 S/16"Factory Applied Clear Pine Complete Unit Extension Jambs) Insect Screen,White Hardware Pack,PSC,Contemporary Folding-White Zone:North-Central U-Factac 0.29, SHGC:0.32, ENERGYSTARti`Quailed:Yes ti_ , 00[}8 1 CR12-3(I--L-14834.16 S 614.16 J- J ,-/ -N RO Size=4'3314"Wx2'0518"N Unit Size=4'3 114"W x 2'0118"H • L L Composite Unit,Wide/Clear Pine,Fligh Performance Low-E4 Glass,No Grille(s),S 9116"Clear Pine Complete unit,Deafer, Mulling Location:Dealer,Mull Type:Narrow Mull.Mull Priority:Vertical Insect Screen,While O \\ °ne �eHardware Pack,PSC,Contemporary Folding-White � 11 T ';,Jn EXT JAMB,6 9116 WALL PR V I ew. F- jY,,.,, EXT JAMB,6 0116 WALL PR LABOR,PERIMETER EXTENSION JAMB APPLICATION,LABOR,Dealer Applied,Complete Unit >:-. 0 0'�S'C Zone:North-Central co Unil U-Factor SHGC ENERGY STAR&Qualified CO.._ t 0.29 0.32 YesV N —c)/ idnuDi‘ 0 ' 0 2 0.29 0.32 Yes 3 029 0.32 Yes ,- 0 N o Quote#: 267505 Print Dale: 04103/2014 Page 3 Of 6 iQ Version: 14.0 fit o in J o Item Qty Item Size(Operation) Location Unit Price Ext.Price o - m o 0 o 5 0 IT 0010 1 0436(AP) $ 755.04 $ 755.04 11.r -I ROSize=4'0"VVx3'6"H UnitSize=3' 11114"Wx3'51/4"N f - 0) Unit,White/Clear Pine,High Performance Low-E4 Glass(Includes 6 9/16'Factory Applied Clear Pine Complete Unit Extension Jambs) Insect Screen,While Handle, Rotating Sash,GW,Metro Style-White Zone:North-Central U•Facton-0.3D, SHGC:0.29, ENERGY SURD Quatiied:Yes • r,.:-: 0011 2 PS5(SR) $ 1200-72 $•. 2401.44 ' F ROSize=6'0314" x6'107Th"H Unit Size=6'0"Wx6'10MI"H c • Uri?,SR handing,WhilelPi White,Low E Tempered Glass Insect Screen,Gliding,White Extension Jamb,Head Member,Interior,Clear Pine,6 9116' <'"D P Extension Jambs,Side Members,interior,Clear Pine,69/16" 1-lardware Trim Set,GO,2 Panel,Tribes-While Support,Sill,Aluminum(Neutral Gray) W COMMENT:"` 4`*""iHIS ITEM WAS QUOTED WITH CLEAR PINE JAMB. UNIT IS WIlE VINYL IN AND OUT.WHITE VINYL JAMB IS 1 1 tJ 1 RECOMMENDED'""'E" 05i -Zone:Noah-Central /' d'1 ....ep U-Factor 129, SI-IGC: ENERGY STARD Qua1Fied:Nn / P id X LL CD 1-- CD m 0 v 0 N _ C0 Quote#l: 267505 Print Date: 04/0312014 Page 4 Of 6 !Q Version: 14.0il 0 c o J N r- r� Item Qiy Item Size(Operation) Location Unit Price Ext Price a o — Irk ---,. 1 i 0012 5 PS9(SR) $ 1427_12 $ 7.135.60 0 IRO Size=8'0314"Wx6 107J8"H Unit Size=8'0"IffxS'103J8"H 51 I '. Unit,SR Handing,White/PI White.Low E Tempered Glass Insect Screen,Gliding.White . 'GO Extension Jamb,Head Member,Interior,Clear Pine,6 9118' Extension Jambs,Side Members,Interior,Clear Pine.5S/16" Hostile reTrim Set,GD.2 Panels Tribeca-White Support,Sill,Aluminum(Neutral Gray) U 1-e"3 eV COMM ENT*""'"""THIS ITEM WAS QUOTED WITH CLEAR PINE JAMB.UNW IS WOE VINYL tN AND OUT.WHITE VINYL JAMB IS RECOMMENDED"""`" ..--- rr Zone:North-Central . LI-Factor 0 29, SHGC:0.33, ENERGY STARID Qttalilled:No r / ODSc 0 - iJ 5d4-961--) Subtotal 10,342.64 Total Load Farrar Tax 8 fi25v Customer Signature - 12.284 ( ) $ 108.30 Grand Total $ 2.1610.94. Dealer Signature "*All g raphi cs viewed from the exterior • "Rough opening dimensions are minimums and may need to be increased to allow for use of building wraps or flashings or sill panning or brackets or fastaners ar other items. - i ff1 Ask to see if all of the products you purchase can be upgraded to be ENERGY STARS qualified. ABY.ABOUT x ENERGY:r m ` w s "' Eg This image Indicates[baths product selected is qualified in the US ENERGY STARS climate zone that you have selected. m Data Is current as ei Septbmber 2Q13.Misdate may(flange overtone due le agoing pmduct changes or updated lest results or requirements Ratings for a3 sizes are apeaIed by NF5G far testing and certification.Ralkigs 0 may vary depsading en theuse artowered glass oreVere rt grille options orgFass rorkttl altitudes ek. i m 0 o Project Comments: - - - d N _ . _ - - _ • o o Quote U: 267505 Print Dale: 04163/2014 Page 5 Of 5 io 0iQ Version: 14.0 0 DECKING TO MATCH EXISTING (I 4" IPE - V.I.F.) - 2X8 DECK JOIST ' A-i h C 17 rT Ir' 1T ti L r- I �i ' I I CABLE RAIL SYSTEM / � �� ' 2X8 I2" 0.C. WITH TO MATCYH EXIST. I J U OCT - 1 2014 i @4 0 _ EXISTING DECK SIMPSON / —CENTER ROW SOLID AS PER RCNYS EXISTING DECK TO REMAIN BRIDGING / V.I.F. / TO REMAIN\ H I HURRICANE CLIP EACHI JOIST EXISTING STAIR BEYOND ;I._ -== T „ ' ! '' ?!r) HOT TUB � ALIGN NEW DECK A I%' ± IPE DECKING TO, CO WITH EXISTING STAIR NEW DECK A— MATCH EXISTING LANDING ALIGN WITH EXISTING STAIR LANDING ® NEW DECK A , : -I `• 6 110T TUB PROVIDE SIDING OR I i U 6 2X8 @ 12"O.C. 2 ROW 1— ›,<...,,,.,...., (±7-8' X 7-8') [\ �- � 1 LATTICE AS DIRECTED SOLID BRIDGING #4 @ 18' 3 ± I/4 IPE DECKING TO BY OWNER OVER (3)2X 10 #4 @ 12" O O MATCH EXISTING 0 EXPOSED STRUCTURE - N GIRDER. TYPICAL /� —' JJQ A�— I 1 A I w � m ) m 2x6 KNEE BRACE @ NOTE: SOIL BEARING / -` COL. LINES 13 EACH z I I I DIRECTION WITH 2 -/2 N I I I VALUE ASSUMED AT I NEW DECK B % j/ U I I %c LAG BOLTS 4 #4 , , _ _._t_ TON PER SQUARE I c J FOOT. ALL FOOTINGS �' 4'" 7'-8" / =oImmomme —I #4 @ 12" I' SHALL REST ON N j51 UNDISTURBED SOIL OF OAT LEAST THAT VALUE \� - — F SECTION A-A WOOD RAIL TRIS SIDE • • AC4 EA. SIDE EN_ SCALE : I/4" = I'-0" I • O'-22" g' 0" 2'-32" / / / / / 2 I' 6" / ��4X4 WOOD POST B A-i 0 NEW DECK PLAN SCALE : 1/4" I'-0" o SIMPSON PS L POST BASE DECK B (HOT TUB PLATFORM) — VERIFY WITH L 3500 PSI AIRR ENTRAINED (I/4"IPE) -HOT TUB EXISTING DECK TO REMAIN r CONC. WITH 4 #5 VERT. I WOOD RAIL SYSTEM MFG'R_ _ _....._ GRP,DE VARIES • A5 PER RCNYS THIS FACE I c,7-)m- 2X8 JOISTS ' AZEK FACIA @ 12" O.C. CO DECK A I V J — — EXISTING DECK FRAMING TO REMAIN I '' L N--\ FT7 I TT7 I rT � I. (1/4" IPE) I� I li_ I I 11 II - AZEK FACIA- II II II COPPER ARMORED - I I B TERMITE +I 2X8 12 0.C. SHIELD/FLASHING = 4X4 POST WITH DIAG. \ PRESSURE TREATED 1'-4" O CONS. PIER BRACE WITH 4-#5 ER . ASSUMED EXISTING FRAMING LUMBER-#2 BARS/ TI CONC. FOOTING I'-0" 0 CONC. PIER SYP PINE OR EQUAL GRADE I I VERIFY IN FIELDWITH 4-#5 VERT. PROVIDE SIDING OR —I— — _I— L O \01/1' BARS POST GIRDER FOOTING ANCHORING DETAIL LATTICE AS DIRECTED I I I O p — BY OWNER OVER I s -I co r — — — OA KNEE BRACE (2)2X8 ——(�}2jE8— — — SCALE : 3" = 1'-0" EXPOSED STRUCTURE- � r --- TYPICAL �"-"`�^�L J \ 1— — — — ---I I w I I 72: 1 �m I I DECK B ABOVE 36" x 12" FOOTINGS I— — — - J �g 9 �2 I I 7' C" I ' SEE DETAIL THIS DWG. O _ _ — �'f 'B2X8 DJ I 12X8 DJ (HIGH) k ,0 SECTION B-B Io @ 1 2" O.C. @ 12" O.C. : SCALE : 1/4" = I'-0" o o m I w. I I `' I 01 O A - - DECK A ABOVE 1( ` 4 BARS X 18" LONG FACT I — A MilrI I I — 2 PER£ „. I k--1( A-I 8" CONC. FOUNDATIONT1 .l " I I I WALL WITH 1 2" x 3'-O" / I GENERAL NOTES i t> CONT. FOOTING 2X8 DJs I) ALL WORK SHALL CONFORM WITH NEW YORK STATE BUILDING AND FIRE CODES AND OTHER KNEE BRACE � CODES HAVING JURISDICTION. THIS SHALL NOT BE CONSTRUED TO MEAN THAT ANY OB — — (2)2X8 — — (2)2X8 — _ N REQUIREMENTS SET FORTH ON THE DRAWINGS MAY BE MODIFIED BECAUSE THEY ARE MORE .. Ck \ \ STRINGENT THAN THE CODE REQUIREMENTS OR BECAUSE THEY ARE NOT SPECIFICALLY REQUIRED I'-O" 0 CONC. PIER 1'-4" 0 CONC. PIER WITH 4-#5 VERT. I'-0" 0 CONC. PIER BY CODE. WITH 4-#5 VERT. BARS O2 WITH 4-#5 VERT. NUMBER DATE REMARKS BARS I10'-42." BARS 2) THE CONTRACTORS SHALL VISIT THE SITE AND VERIFY ALL CONDITIONS AT THE SITE PRIOR TO g , 9g/ THE START OF WORK, AND REPORT ANY DISCREPANCIES TO THE ARCHITECT. /X / 3) CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL EXISTING DIMENSIONS AND / 2 I'-6" / ROBERT C. TAST, A.I.A. CONDITIONS. ARCHITECT OR ENGINEER OF RECORD MUST BE NOTIFIED OF ANY VARIATIONS ARCHITECT FROM THE DIMENSION AND CONDITIONS SHOWN BY THESE DRAWINGS. B b20 OSTR�NDER AVENUE 4) ALL MATERIALS AND CONSTRUCTION TO BE INCORPORATED INTO THE WORK SHALL BE IN STRICT ACCORDANCE WITH THE LATEST EDITION OF APPLICABLE ASTM SPECIFICATION AND A-I RI� OST�D, NY 110101CONFORM TO THE STANDARDS AND RECOMMENDATIONS OF THE VARIOUS TRADE INSTITUTES WHERE APPLICABLE. ALL MATERIALS INCORPORATED INTO THE WORK SHALL BE NEW. 0 NEW DECK FRAMING PLAN 631-51,1-8106i-8106 F 631-727-0144 SCALE : 1/4" = 1'-0" 5) THE ARCHITECT OF RECORD HAS NOT BEEN RETAINED FOR SUPERVISION AND ASSUMES NO RESPONSIBILITY FOR THE QUALITY AND PERFORMANCE OF WORK BEING DONE. 1=ERRAR� RESIDENCE DECK ADDITION 6) ALL DIMENSIONS NOTED V.I.F. (VERIFY IN FIELD) SHALL BE VERIFIED BY THE CONTRACTOR AND GREI=NPOTHRT OLD SUFFOLK IF THEY ARE NOT CONSISTENT WITH GIVEN DIMENSIONS, THE ARCHITECT SHALL BE NOTIFIED. TOWN OF 5 OCOUNTY,NEW YORK DISTRICT 1000,SECTION 44,BLOCK I,LOT 2Q 7) FRAMING: CONTRACTOR SHALL PROVIDE ALL REQUIRED BLOCKING, BACKING, FRAMING, HANGERS, OR OTHER SUPPORT AS NECESSARY FOR ALL FIXTURES, EQUIPMENT, CABINETRY, FURNISHINGS, AND ALL OTHER ITEMS REQUIRING THE SAME. IT IS THE CONTRACTORS RESPONSIBILITY TO COORDINATE WITH MFR. AND INSTALLER AND REVIEW SHOP DRAWINGS FOR BACKING, UTILITIES CONNECTION, ETC. 8) ALL LUMBER AND CONNECTIONS SHALL SE IN ACCORDANCE WITH THE NEW YORK STATE BUILDING ;;'..\\ CODE AND WITH THE NATIONAL DESIGN SPECIFICATIONS FOR STRESS GRADED LUMBER AND ITS FASTENINGS. LUMBER SHALL BE FURNISHED AND INSTALLED, COMPLETE WITH ALL FASTENINGS, � DRAWING PREPARED SEPT. 29,2014 ANCHORS, HANGERS, ETC. REQUIRED TO COMPLETE THE WORK. ALL GALV. STEEL BOLTS CONNECTING WOOD MEMBERS SHALL BE SUPPLIED WITHI AND TIGHTENED AGAINST GALV. STEEL WASHERS OR PLATES. SCALE: AS NOTED JOIST HANGERS AND CONNECTORS, AND OTHER SPECIAL CONNECTIONS AND HARDWARE MUST BE .IOB NO.: 2014-14 INSTALLED IN ACCORDANCE WITH NEW YORK STATE BUILDING CODE REQUIREMENTS. WHERE FASTENERS ARE NOT SPECIFICALLY INDICATED OR SPECIFIED THEY SHALL BE FURNISHED IN ADEQUATE NUMBER AND D 6 O. ;_ SIZE. r 1i'° v",,,,,...., `^.�,. 1�:. 5) ALL CARPENTRY WORK SHALL BE PERFORMED IN CONCORDANCE WITH GOOD TRADE PRACTICE, RECOMMENDATIONS OF MANUFACTURERS' AND IN CONFORMANCE WITH THE NEW YORK STATE BUILDING �I r CODE, AND THESE SPECIFICATIONS: t,..4.7, ..\ 10) FASTEN SECURELY ALL PARTS OF CARPIENTRY WORK IN THEIR PROPER PLACE, BRACE, PLUMB AND ., LEVEL ALL MEMBERS AND SECURE WITH SUFFICIENT NAILS, SPIKES AND BOLTS TO INSURE RIGIDITY. - ._ ek°�.T,./v' A—i r