Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
40138-Z
o�OS11Ff01,1eo� Town of Southold 10/9/2015 ja‘ y� P.O.Box 1179 0€ t o i y 11 53095 Main Rd °,41 ,,,0 Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 37831 Date: 10/9/2015 THIS CERTIFIES that the building GENERATOR Location of Property: 1020 Old North Rd, Southold SCTM#: 473889 Sec/Block/Lot: 55.-1-6.1 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 9/22/2015 pursuant to which Building Permit No. 40138 dated 9/29/2015 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: ACCESSORY GENERATOR AS APPLIED FOR The certificate is issued to Haman,William&Haman,Carolyn of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 40138 10-05-2015 PLUMBERS CERTIFICATION DATED --7_..„.._Hvzxr„,.._ Authorized Signature SUFFeTOWN OF SOUTHOLD BUILDING DEPARTMENT cam 0) TOWN CLERK'S OFFICE Q� SOUTHOLD, NY * / BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 40138 Date: 9/29/2015 Permission is hereby granted to: Haman, William & Haman, Carolyn 1020 Old North Rd Southold, NY 11971 To: install an accessory generator as applied for. At premises located at: 1020 Old North Rd, Southold SCTM # 473889 Sec/Block/Lot# 55.-1-6.1 Pursuant to application dated 9/22/2015 and approved by the Building Inspector. To expire on 3/30/2017. Fees: ACCESSORY $100.00 CO -ACCESSORY BUILDING $50.00 ELECTRIC $85.00 Total: $235.00 Building Inspector Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings,property lines, streets, and unusual natural or topographic features: 2. Final Approval from Health Dept. of water supply and sewerage-disposal (S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead. 5. Commercial building, industrial building,multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings(prior to April 9, 1957)non-conforming uses,or buildings and"pre-existing"land uses: 1. Accurate survey of property showing all property lines, streets,building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant.If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees ,1. Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00,Alterations to dwelling$50.00, Swimming pool$50.00,Accessory building$50.00,Additions to accessory building$50.00,Businesses$50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy-$.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy-Residential$15.00, Commercial$15.00 / Date. ' 2 v�� New Construction: Old or Pre-existing Building:lding: (check one) Oil)Location of Property: I OI I )O t�1j o \o,. , 3OUT( House No. Street Hamlet Owner or Owners of Property: PA, ' Ceo,ar, Suffolk County Tax Map No 1000, Section 66 Bloc C Lot 6 11 Subdivision Filed Map. Lot: Permit No. Date of Permit. Applicant: Health Dept.Approval: Underwriters Approval: Planning Board Approval: Request for: Temporary Certificate Final Certificate: (check one) Fee Submitted: $ j PP g A licant i nature 000. iii..,�- I I° A**0 SOUlyOI . Town Hall Annex �� ~ O : Telephone(631)765-1802 54375 Main Road 1 IP 4 Z Fax(631)765-9502 P.O.Box 1179 % i ' °<.% Q % roger.richert(a�town.southold.ny.us Southold,NY 11971-0959 �' y0 �1 is —•_... // BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION Issued To: William Haman Address: 1020 Old North Road City: Southold St: New York Zip: 11971 Building Permit#. 40138 Section: 55 Block: 1 Lot: 6.1 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: Ocean Electric License No: 4015-E SITE DETAILS Office Use Only Residential X Indoor Basement Service Only Commerical Outdoor X 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures HID Fixtures Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel NC Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel NC Blower Range Recpt Fluorescent Fixture Pumps Transformer Appliances Dryer Recpt Emergency Fixtures Time Clocks Disconnect Switches Twist Lock Exit Fixtures TVSS Other Equipment. 12 kw Standby Generator with 200A Auto Transfer Switch Notes: Inspector Signature: eillik Date: October 5, 2015 +. Electncal 81 Compliance Form.xls • % Si ry;; To mal!Alpcx * * ; Telephone(631)765.1865 54375 Main Road ; ro er. ert flan lsouu9 P.O.Box 1179 . w �Clh tllQt .tly.us Southold,NY 11971-0959 : '• BUILDING DEPARTMENT ` TOWN OF SOUTHOLD APPLICATION FOR ELECTRICAL INSPECTION : REQUESTED BY: qc,Ac_4 VY1E„C ��2 � Data: 9-/ Company Name: , - Name: •License No.: Address: i ,N, Phone No.: vio: JOBSITE INFORMATION: (*Indicates required information) *Name: *Address: /Ori o< ► a *Cross Street: *Phone No.. Permit No.: 0 ( 3i. Tax-Map District: 1000 Section: Black: ' Lot: - *BRIEF DESCRIPTION OF WORK(Please Print Clearly) h\ .4.\• '- . 5' . __a►.,.•. Cris (Please Circle All That Apply) -! *Is job ready for inspection: YES MEP Rough in Final *Do you need a Temp Certificate: YES Temp Information(If needed) - *Service Size: 1 Phase 3Phase 100 150 200 300 350 400 Other // *New Service: Re-connect Underground Number of Meters Change of Service Overhead �7`� Additional Information: PAYMENT DUE WITH APPLICATION . I I� 11241equest for Inspection Form 4 /66- q P tt . I 933-A L000/1,000c1 L80-1 L8LOL83 L89 o!-440913 u Pao0 -Wad 170:L L 9 L r33-60 h,,,,' "4114---__. ,,:,€ - ' 4, '* *1 L- D't i ' 'fp, k-i TOWN OF SOUTHOLD BUILDING DEPT. 765.1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) &ELECTRICAL (FINAL) REMARKS: ,r/.1 /4--L___Za---e- - - 0 - -- DATE / 5 INSPECTOR r /r' FIELD 3 SP�4 CSN Rt rcutio 'D j. •,,.• CO T J • S„...,..,,, 'FOUNDATION(1ST) . .. .• ., ... .. - _ .., , • , . CO .......... ....,+.....mo ,. r • . ., • FOUNDATION(2ND}) •• ••••---+••-' • • . ... •.A.. •��-:',�ter+, ..` • J' J ' • o ROUGH FRAMING& ...Q,, 1-3 . • • o ZI INSULATION PE.N,Y, ._..,44.04._,. .; STATE ENERGY CODE • • '• FINAL „.rte. - • • , -,. . _ „ I ''- , may..'N' t11'"', ..,,,w...1.---‘ _. a-h•,{-',., t; .. . T-n(• , i e-. "4 ••PiAfit'' Ts O ni • r r J. J •y i • 'ti,4 •t J .r, .J • `. ,. - . t ,- - , I ♦ — _ .t .. ' /. 1. s,` 1.x•4 I TOWN OF SOUTHOLD ' BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following;before applying? TOWN HALL ' ' '' - `-, ` ' `• ,-`‘`r ' ' ` , .,` 'Boar-d'of Health SOUTHOLD, NY 11971 . - _. - . -__ . , - 4 sets of'Building Plans` I ' ' TEL: (631) 765-1802Planning Board approval FAX: (631) 765-9502 - - - - /D 1 F-- . Survey'-' ' ' ' I SoutholdTown.NorthFork.net PERMIT NO. . . - --elreay�ck-= ==_ _ �i. , .., n �q SepLi Form ,'o .tel { `-, Trustees I i -ru p1catjq HIMHIM. .. ; it Examined A . ' ' : ,20 ' i--- Single&Separate I I/ , ( 5to riAWfart@f Assessment Farm e I ; -, it f:1J1 ;gildi r; �otrta�t: Approved ,20 �. i. r Mail to: , Disapproved a/c ', - - • ,.f- -, Phone:F', t-'" '76 511— 557/ Expiration D� 20 1 _ - - -h- I i,,,, , A PR VEDAS NOTED '- r: '- .erector "r-% 'D — AT _( B40-.#__---, 1 L " \ B` N � • - :. APPLICATTCNFORABUILDINGPERM ' _ ' 07, P ; 1.1 .1 ', ,r { NOTIFY BI8 AU TO MF`O,ERN TTHAET I' r" Date-O ' n ' l,l,.' , 20 1.5 `' INSTRUCTQNS== ' W1, FOO REQUIRED ;,,; {; FOR POURED COIiI,CRETE a. This application MUST be completely-filled in by`tj%pe�vfiter or in ank rid_ ubm4t%Mali-BTWANG sRekcoNi,t116 sets of plans,accurate plot plan to scale.Fee according to schedule. INSULATION b.Plot plan showing•location of lot.and-of buildings.on-premises;'relati'onship to,ad oinina•Lpre I� FiB l l iltr,R r areas, and waterways. R C0 PLETE FOR C.O. c.The work covered by this a pplicationomayinot.be commenced;l�efore;issuance of, Lit�ION SHALL MEET Tl- d. Upon approval of this application,the Building Inspector will issue a Building P EbtiWi �i tTl�t�t 1 3CJ P shall be kept on the premises available.for inspection throughout the,work, .,='YORK STATE. NOT'RESPONSIBLE r e.No building shall be occupied`or used in*Hole.or iii pait or any purpose what scbt9bint4htNgilkisdpunctgririoRa issues a Certificate of Occupancy. f. Every building permit shall expire if the work authorized,has_riot commenced within 12 months after the date of issuance or has not been completed within 18 months from such;d`ate:If no zoning amendments or other regulations affecting the property have been enacted in theInterim,the Building Inspect i ii `authorize; in writing,the extension of the permit for an addition six months. Thereafter, a new permit shall be required. I APPLICATION ISHEREBYMADE:toitheyB,uilding,;Departmentfor the issuance of a Building Permit-pi to the I ..y t Building Zone Ordinance of the'Town,of•S,quthold,%Suffolk Cohrity;Nevi 4drk;and otheedpplicable Laws,;Ordinances,or Regulations, for the construction of buildings,additions, or alterr. tiondr s for removal orsdemolition.as herein described. The applicant agrees to comply with all applicable laws, ordinances,building',cgd'e;;housing'code,and regulations;'and to admit authorized inspectors on premises and in buildingfor n c sary inspections. cc ANY ,.,: , :; , , , I , USEIS UNLAWFUL , , , „,(Signature of applicant or name,if a corporation) WITHOUT cE'TIH6cAT I i . 05 OCCUPANCY ' ' r-_-,, ----, Ivlailirg'.addres's'Of applicant)' ' State whether applicant is owner, lessee.,_agent,..architect, engineer, general contractor, electrician, plurnI ber or builder I Name of owner.of premises C .-. QL Nu 1-7, - i`Vrta4. J. (As'on the tax roll,orr.latest deed), 1, &l,L CODE$ OFE If applicant is a corporation, signature of duly authorized officer �� iW r`�� ,� S- dF,s-r: & TOWN COD S (Name and title of corporate officer) i 'r AS REt U.l,Ficn AY' `-'Ol``1p1TlOf�ls OF Builders License No. SOUTriOLD SOWN[5A Plumbers'License No. ” ` ` ''' --- 4,.....77.: SOUTHOL�;OJNPLP,NNiNGBOARD Electricians LicenseNo. � r ;yin{r ti�i�,,•. IRIiNjEES Other Trade's License No. SO`w'''i'-. U.S.DEC 1. Location of land on ,which propos d work will be done: d>✓ A 9 ooZ-r a 0aTHD4_, D House Number Street �j IHamlet CountyTax Map No. 1000 Section `J Block l Lot l l 1 Subdivision Filed Map No. Lot • 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy , • , , b. Intended use arid occupancy r , iii , _ 3. Nature of work(check which,app'licable): New Building - --- Addition Alteration Repair Removal, 1 Demolition Other Work 24,0_.(___2,c176,--0 ' • (Description) 4. Estimated Cost .•,?i �"; - `;" Fee (To be paid on filing this application) ., , 5, If dwelling, number of'dwelling'units Number of dwelling units on each-floor If garage;•riumberof'ca r's' 6. If business, commercial or mixed,occupancy, specify nature and extent of each type of use. 7. Dimensions of existing structures, if any: Front Rear Depth Height . '''Number of Stories Dimensions of same structure with alterations or additions: Front 'Rear Depth Height -1C-1._.ri,' ," "f 8 :, -:;.i.-•Number of Stories 8. Dimensions of entire new construction ,ErontvA A,,- t,is it, ..iL. .v :rRe'ar`r,.,a�;i .;' Depth Height Number of"Stories ` s 9. Size of lot: Front - Rear . .:,.7t 1' '.).,',,i ; • • , Depth 10. Date of Purchase ;• J., Nam'e,of Former.Owner ' ..• , ' . - , • 11. Zone or use district in Which premises dre.sittiated-'!..Y.' , • , . „ ,' • , 12. Does proposed construction';violate anyrzoning law; ordmance'or'regulation'?YESv NO 13. Will lot be re-graded'? YES NO Will excess fill be removed s'? YES fr'oyrit:-premises` 'NO 14. Names of Owner of premises „ . , ,. • :Address •:.,:. ., . . _, , , , :Phone"No., Nine of Architect ... :_, ., , "w t" ; .' ° a . . , .. :"iAddress,.� .'��= f �ii,,�. •,`, ' . . .Phone No .. Name of Contractor • . • . :u,; - • A`dd'ress- ��� �: f-i,. -Phone No.' 15 a. Is this property,within 100;feet'of:a<tidal we,tland.pr-aft`.esh- titer wetland? JYES;'.:: '+NO' , * IF YES, SOUTHOLD,TOWN.rIRU'STEES, i�, •II4"'''' r "'� • &D:FCgPERtviIT'S'IVIAY'jBEr,REQUIRED: . b. Is this property:Within'300;feet;ofa<tidal-wetldrid7.*1YES:'iI NOw;,';;: * IF YES; D.E.C. PERMITS.:MAY'BE REQUIRED: i;i"' ' ..1:'''''' " . ;;' ''• ' ' 1.1:;;:,,:{i'•, : '•'',':;:..,, 16. Provide survey, to scale, with accurate foundation plan and,distarices to property lines. 17. If elevation at any point"oii'prolierty"is"at 10 feet or-below, must provide topographical data on survey. 18. Are there any covenants•.and'.restrictions with respect to this pioperty? * YES ' NO * IF YES, PROVIDE A COPY. STATE OF ,; y , ,t, , qt"i✓a., 'J NEW YORK)' SS: COUNTY OF ) , , --\\ -- - . - - 4 KOLA hJ (�i - V14 vA-1U ., .being,dulyr sw;o�n, depbses_and says that(s)he is the-applicant (Name of individual signing contract)above.named; '• . ° 1, '" (S)He is the (Contractor,Agent, Corporate Officer,etc.) - - .. of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and-belief; and that the work will be performed in the manner set forth in the application filed therewith. . Swor to before me this oe day of ± 2015 ' n- , ' ' . t ' u A. 4/it tux' Notary Public t Signa e of Applicant Notary Public Statcg of New York • No.0f106190696 •, Qualified in Suffolk County- __ - Commission Expires July 28.201(. ---- - - --- _ k i r1, I / \ .,..,' r(.›.:4/-:'?:: A L/C• --'>. - 1,,- , ..,..,_._ ArC -----7, --/ - ;-, • . ...... . ... 131',...c_:,,, - t 1 , ,, S,5".C'Cr. •,..7...., P.. /-rt‘--\ C7,/ -,,<::•4-10----c-'144.:':-)----...':-:."...---: ,C--;.3.-.:''-'------,;' 4, I14 // , --, (--- , r-)----- • .--, , ..) . ..- , c . , iCe .:1 r_ t•:. - 1 ,.. ... i. ,...:'; 't, 'I.1, . .-.1,-, ',''. ,7 i • 1 t . , ----I ..... ..-'-"..7.7 i 4'(.' 1 k.:„...... 4 I . .-.4 i ,-.... . '7.--- c t• i _....-. V . .„ . V• Vr''' - 1/4.3.'0 .." 12 \s/ .. , 755:..7 0 '... ,-7i,'—' i i /—.:• il. '."' (.'", 1'7 e-e,CI 7/:-• 'I-I-4. .1---:::ti..-:r',I. .,-,:::, ' ,,---, -1'..,1c - ...-.-74• '' filVt'r if -, i 7)/lii.'77, .e., , - 4 -',-=',",.;,-.:..- ,..,..,--e,..----,'?..-- ,.50 '--z--- // ;-r ' i, --;:-.,-;-1- Va/./' 77, 'zi ,0: /1 ,,,,, .....-t.....„,-, o .---, -...,::)i-f 17:.;(p ef I.....ir-r-•,, - .. 1/...,:::: ---- . - 6-ree i '17; ,', 7 /V'*:'; -- 1L- ...--- - .0. • -... ....; „..v.,,,.,:,....,,..4,..1-:;,.,,,,,,,,w.: , 3,...,..,,. - • ..14, ...-,.:.,?::-.-......- ..'... :-.,":'.7t.i.. ... ' '4: ,' • : . Models: 1 0/1 2R ESV KOHLEIt® Power SystemsMulti-Fuel LPG/Natural Gas 09001 Standard Features MEER ii POWER SYSTEMS • RDC2 Controller NATIONALLY REGISTERED o One digital controller manages both the generator set _r,µ sand transfer switch functions (with optional Model RXT °tµ ,`;77, '" ' transfer switch). 1. -, '=' o Designed for today's most sophisticated electronics. "' ';�`L' '';;"i,--, x, „: ;, o Electronic speed control responds quickly to varying . ,. household demand. ,,,,,:,,,,,;(1 .1 , _`_,„!,,-;,. .;•, o Digital voltage regulation protects your sensitive r { . ,.,'..,.g: ; 4,-,,,-,,,,,, electronics from harmonic distortion and unstable power % „',,.. 5. quality. '.�.,.. d x.-,...r:~<� °-,rs a,. o Two-line, backlit LCD display with adjustable contrast is ; ' r,':,=`r ' `_„. jr: easy to read,even in direct sunlight or low light. . :2-: :-.-``1,— o OnCue®Plus Generator Management System for remote monitoring is included with every generator. • Kohler Engine Features The Kohler® Advantage a Kohler Series 7000 V-twin engine with efficient OHV design • High Quality Power o Powerful, reliable air-cooled performance Kohler home generators provide advanced voltage and o Simple field conversion between natural gas and LPG frequency regulation along with ultra-low levels of fuels while maintaining emission certification harmonic distortion for excellent generator power quality to . Desi Designed for EasyInstallation protect your valuable electronics. g o Steel base • Extraordinary Reliability o Hinged, locking roof Kohler is known for extraordinary reliability and o Fuel and electrical connections through the enclosure performance and backs that up with a 5-year or 2000 hour wall eliminate the need for stub-ups throw h the bottom limited warranty. g o Accepts natural gas fuel pressure as low as 3.5 inches • Powerful Performance o Load connection terminal block allows easy field wiring Exclusive Powerboost"" technology provides excellent o Designed for outdoor installation only starting power. The Kohler 12 kW generator can easily start and run a 5 ton air conditioner with up to 5 kW • Approved for stationary standby applications in locations preload.* served by a reliable utility source • Enclosure • Meets 181 mph wind rating Bold new Kohler design in steel,dipped in e-coat for extra • Certifications corrosion protection and painted with a durable powder o Meets emission regulations for U.S. Environmental coat finish Protection Agency(EPA)40 CFR 60 stationary source • Quiet Operation standards with both LPG and natural gas. Kohler home generators provide quiet, neighborhood- Note: CARB does not regulate emergency standby friendly performance. generators outputting less than 50 HR Only the EPA standards apply. o UL 2200 listed (60 Hz model) o CSA certification available(60 Hz model) o Accepted by the Massachusetts Board of Registration of Plumbers and Gas Fitters. Generator Ratings Standby Ratings Natural Gas LPG Model Voltage Phase Hz Alternator kW/kVA Amps kW/kVA • Amps 10RESV 120/240 1 60 2F3 9/9 37.5 10/10 41.7 12RESV, 120/240 1 60 2F4 11/11 45.8 12/12 50 RATINGS Standby ratings apply to installations served by a reliable utility source All single-phase units are rated at 1 0power factor The standby rating is applicable to variable loads with an average load factor of 80%for the duration of the power outage No overload capacity is specified at this rating Ratings are in accordance with ISO-3046/1,BS5514,AS2789,and DIN 6271 GENERAL GUIDELINES FOR DERATING ALTITUDE.Derate4%per 305m(1000ft)elevation above 153m(5006) TEMPERATURE Derate 2%per 5 5°C(10°F)temperature increase above 16°C(60°F) Availability is subject to change without notice The generator set manufacturer reserves the right to change the design or specifications without notice and without any obligation or liability whatsoever Contact your local Kohler Co generator distributor for availability • Check the appliance manufacturer's specifications for actual power requirements Consult a Kohler®Power Systems professional to calculate your exact residential power system requirements G4-241 (10/12RESV)8/14 Alternator Specifications Alternator Specifications Alternator Features PowerBoost" Generator • Compliance with NEMA, IEEE,and ANSI standards for Specifications 1-Phase p Manufacturertemperature rise Kohler Output reconnectable 120/240 • Self-ventilated and dripproof construction Type 2-Pole,Rotating Field • Windings are vacuum-impregnated with epoxy varnish for Leads,quantity 4 dependability and long life. Voltage regulator Digital • Superior voltage waveform and minimum harmonic Insulation: NEMA MGi-1.66 distortion from skewed alternator construction Material Class H • Digital voltage regulator with±1.0% no-load to full-load Temperature rise Class H - RMS regulation Bearing.quantity,type 1,Sealed Ball • Rotating-field alternator with static exciter for excellent Coupling Direct load response Amortisseur windings Full • Total harmonic distortion (THD)from no load to full load with Voltage regulation,no-load to full-load a linear load is less than 5%. RMS ±.1.0% One-step load acceptance 100%of Rating Peak motor starting kVA. (35%dip for voltages below) 240 V,2F3 (60 Hz) 16.8 240 V,2F4 (60 Hz) 20.3 Application Data Engine Engine Electrical Engine Specifications 10RESV 12RESV Engine Electrical System 10RESV 12RESV Manufacturer Kohler Ignition system Electronic, Engine:model,type KT725 Capacitive Discharge Cylinder arrangement V-2 Starter motor rated voltage(DC) 12 Displacement,cm3(cu.in.) 725(44) Battery(purchased separately): Bore and stroke,mm(in.) 83 x 67(3.3 x 2.6) Ground Negative Compression ratio 9.0.1 Volts(DC) 12 Main bearings:quantity,type 2,Parent Material Battery quantity 1 Rated RPM Recommended cold cranking amps: 60 Hz 3600 (CCA)rating for-18°C(0°F) 500 Max.engine power at rated rpm,kW(HP) Group size 51 LPG,60 Hz 16(21.4) Lubrication Natural gas,60 Hz 13.4(18) Cylinder head material Aluminum Lubricating System 10RESV 12RESV Valve material Steei/Stelijte® Type Full Pressure Oil capacity(with filter),L(qt.)* 1.9(2.0) Piston type and material Aluminum Alloy Crankshaft material Heat Treated,Ductile Iron Oil filter:quantity,type 1,Cartndge Governor:type Electronic * Oil capacity for a new,dry engine. Frequency regulation,no load to full load Isochronous Fuel Pipe Size Frequency regulation,steady state ±1.0% Minimum Gas Pipe Size Recommendation,in.NPT Air cleaner type Dry 10RESV 12RESV Exhaust Natural Natural Exhaust System 10RESV 12RESV Pipe Gas LPG Gas LPG Length, 157,100 185,297 208,550 257,000 Exhaust temperature exiting the m(ft.) Btu/hr. Btu/hr. Btu/hr. Btu/hr. enclosure at rated kW,dry, °C(°F) 106(224) 106(224) 8 (P5) 3/4 3/4 3/4 3/4 15 (50) 1 3/4 1 3/4 30 (100) 1 1 1 1 46 (150) 1 1 1 1 61 (200) 1 1/4 1 1 1/4 1 G4-241 (10/12RESV)8/14 Fuel Requirements RDC2 Controller Fuel System 10RESV 12RESV Fuel types Natural Gas or LPG . Fuel supply inlet 1/2 NPT Voltage 240 Fuel supply pressure,kPa(in H20). Freq 600 Hz r� Natural gas .87-2.7(3 5-11) W LP 1 7-2 7(7-11) 'Tom= Fuel Composition Limits* Nat.Gas LPG '" \ -. -6 Methane,%by volume(minimum) 90 min — i S� Ethane,%by volume(maximum) 4.0 max. — The RDC2 controller provides integrated control for the Propane,%by volume 1 0 max 85 min. generator set, Kohler@ Model RXT transfer switch, Propene,%by volume(maximum) 0 1 max. 5 0 max programmable interface module(PIM),and load control module C4 and higher,%by volume 0 3 max 2 5 max (LCM). Sulfur,ppm mass(maximum) 25 max Lower heatin value, The RDC2 controller's 2-line LCD screen displays status MJ/m3(Btu/ft3), (minimum) 33.2(890) 84.2(2260) messages and system settings that are clear and easy to read, * Contact your local distributor for suitability and rating derates based even in direct sunlight or low light. on fuel compositions outside these limits RDC2 Controller Features Operation Requirements • Membrane keypad Fuel Consumption o OFF,AUTO,and RUN pushbuttons Fuel o Select and arrow buttons for access to system Model Type %Load Fuel Consumption,m3/hr.(cfh) configuration and adjustment menus 100 4.2 (146) • LED indicators for OFF,AUTO,and RUN modes 75 3.4 (119) • LED indicators for utility power and generator set source Natural 50 2.9 i of availability and ATS position (Model RXT transfer switch Gas ( ) required) 25 2.4 (86) • LCD display 10RESV Exercise 2.0 (73) o Two lines x 16 characters per line 100 2.0 (72) o Backlit display with adjustable contrast for excellent 75 1.7 (60) visibility in all lighting conditions LPG 50 1.4 (51) • Scrolling system status display 25 1.2 (42) o Generator set status Exercise 1 0 (37) o Voltage and frequency 100 4.2 (149) o Engine temperature o Oil pressure 75 3.6 (125) Natural o Battery voltage Gas 50 2.7 (95) o Engine runtime hours 25 2 0 (70) • Date and time displays Exercise 1.5 (54) 12RESV 100 2.3 (80) • Smart engine cooldown senses engine temperature • Digital isochronous governor to maintain steady-state speed 75 1.9 (68) at all loads LPG 50 1 6 (56) c Digital voltage regulation: ±1.0% RMS no-load to full-load 25 1.2 (43) • Automatic start with programmed cranking cycle Exercise 0.9 (32) • Programmable exerciser can be set to start automatically on Nominal fuel rating. Natural gas' 37 MJ/m3(1000 Btu/ft ) any future day and time,and run every week or every two LPG: 93 MJ/m3(2500 Btu/ft.3) weeks LPG conversion factors. 8.58 ft.3=1 lb. • Exercise modes 0.535 m3=1 kg 36.39 ft.3 =1 gal o Unloaded weekly exercise with complete system diagnostics Sound Data o Unloaded full-speed exercise a Loaded full-speed exercise(Model RXT ATS required) Model 10RESV and 12RESV 8 point logarithmic average sound • Front-access mini USB connector for SiteTech- or levels are 67 dB(A) during weekly engine exercise and 71 dB(A) USB Utility connection during full-speed generator diagnostics and normal operation. • Integral Ethernet connector for Kohler@ OnCue®Plus The lowest point sound levels are 64 dB(A) and 69 dB(A) • Built-in 2.5 amp battery charger respectively as compared to competitor ratings.* • Remote two-wire start/stop capability for optional connection All sound levels are measured at 7 meters with no load. of Model RDT or RSB transfer switches * Lowest of 8 points measured around the generator.Sound levels at other points around generator may vary depending on installation parameters See additional controller features on the next page. G4-241 (10/12RESV)8/14 KOHLER CO,Kohler,Wisconsin 53044 USA Kohler Power Systems Phone 920-457-4441,Fax 920-459-1646 Asia Pacific Headquarters For the nearest sales and service outlet in the 7 Jurong Pier Road US and Canada,phone 1-800-544-2444 Singapore 619159 KohlerPower.com Phone(65)6264-6422,Fax(65)6264-6455 Additional RDC2 Controller Features Available Options, Continued • Diagnostic messages Electrical System o Displays diagnostic messages for the engine,generator, ❑ Battery Model RXT transfer switch, programmable interface module (PIM), and load control module(LCM) ❑ Battery heater o Over 70 diagnostic messages can be displayed Fuel System • Maintenance reminders ❑ Braided stainless steel flexible fuel line • System settings - o System voltage,frequency,and phase Literature o •Voltage adjustment ❑ General maintenance literature kit o Measurement system, English or metric ❑ Overhaul literature kit • ATS status(Model RXT ATS required) Production literature kit o Source availability o ATS position (normal/utility or emergency/generator) Starting Aids o Source voltage and frequency ❑ Carburetor heater, 120 VAC(recommended for • ATS control(Model RXT ATS required) reliable starting at temperatures below 0°C[32°F]) o Source voltage and frequency settings ❑ Fuel regulator heater pad (20RESA; recommended for o Engine start time delay reliable starting at temperatures below-18°C[0°F]) o Transfer time delays Kohler®Automatic Transfer Switch o Voltage calibration o Fixed pickup and dropout settings ❑ Model RXT,see specification sheet G11-121 • Programmable Interface Module (PIM)status displays ❑ Model RDT,see specification sheet G11-98 o Input status (active/inactive) ❑ Model RSB,see specification sheet G11-101 o Output status(active/inactive) ❑ Other Kohler®ATS • Load control module (LCM) menus Miscellaneous Accessories o Load status o Test function ❑ Generator Set Standard Features ❑ • Battery cables • CARB(14RESA only) and EPA certified fuel system • Corrosion-proof polymer sound enclosure • Critical silencer Generator Set Dimensions and Weights • Field connection terminal block Overall Size,Lx W x H. 1216 x 665 x 733 mm (48 x 26.2 x 29 in) • Fuel solenoid valve and secondary regulator Shipping Weight. 14RESA 191 kg(420 lb.) • Line circuit breaker: 20RESA 243 kg (535 lb.) 14RESA: 70 amps 20RESA: 100 amps L • Multi-fuel system, LPG/natural gas,field-convertible ) >` • Oil drain extension with shutoff valve • Premium 5-year limited warranty H • 18-month limited warranty for non-standby(off-grid) applications(14RESA only) • RDC2 generator set/ATS controller — 11\) t W • Rodent-resistant construction NOTE Dimensions are provided for reference only and should not be used for planning • Sound-deadening,flame-retardant foam per UL 94, installation Contact your local distributor for more detailed information class HF-1 DISTRIBUTED BY: Available Options Communication Accessories ❑ OnCue®Generator Management System Controller Accessories ❑ Programmable Interface Module (PIM) (provides 2 digital inputs and 6 relay outputs) U Load Control Module(LCM) (provides 4 power relays and 2 HVAC relays) ©2011,2012 by Kohler Co All nghts reserved G4-209 (14/20RESA) 8/12b