Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
39554-Z
,�\gSiWeiNeOG Box 1179 P.O.Town of Southold 10/7/2015 ''o = macf„ ' �' 53095 Main Rd -440 ,1,0- Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 37823 Date: 10/7/2015 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 2000 Harbor Ln, Cutchogue SCTM#: 473889 Sec/Block/Lot: 103.-1-20.12 , Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 2/17/2015 pursuant to which Building Permit No. 39554 dated 2/24/2015 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: ROOF MOUNTED SOLAR PANELS TO AN EXISTING ONE FAMILY DWELLING AS APPLIED FOR The certificate is issued to Nolan,Mark&Nolan,Kristine of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 39554 09-30-2015 PLUMBERS CERTIFICATION DATED Authorized Signature TOWN OF SOUTHOLD 0'0' FFUI,y` . BUILDING DEPARTMENT iy z= TOWN CLERK'S OFFICE SOUTHOLD, NY ;Gyp 0�� S �`, BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES • WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 39554 Date: 2/24/2015 Permission is hereby granted to: Nolan, Mark & Nolan, Kristine 2000 Harbor Ln Cutchogue, NY 11935 To: install an roof mounted electric solar panel system as applied for • At premises located at: 2000 Harbor Ln, Cutchogue SCTM # 473889 Sec/Block/Lot# 103.-1-20.12 Pursuant to application dated 2/17/2015 and approved by the Building Inspector. To expire on 8/25/2016. Fees: SOLAR PANELS $50.00 CO -ALTERATION TO DWELLING $50.00 ELECTRIC $100.00 Total: $200.00 A , ,L, Building Inspector Form‘No.6 ' TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings,property lines,streets,and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal(S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1%lead. 5. Commercial building,industrial building,multiple residences and similar buildings and installations,a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings(prior to April 9, 1957)non-conforming uses,or buildings and"pre-existing"land uses: 1. Accurate survey of property showing all property lines, streets,building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00,Alterations to dwelling$50.00, Swimming pool $50.00,Accessory building$50.00,Additions to accessory building$50.00,Businesses$50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy-$.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy-Residential$15.00,Commercial$15.00 Date. 2• I S • 1 S New Construction: Old or Pre-existing Building: / (check one) Location of Property: 2000 HAAME LANE CorcHo 4 vE House No. Street Hamlet Owner or Owners of Property: AA Reg_ " k2TsTIWvE Noi A'V Suffolk County Tax Map No 1000, Section 103 Block I Lot 2 .00 IZ Subdivision Filed Map. Lot: Permit No. � cG J Date of Permit. Applicant: Health Dept.Approval: Underwriters Approval: Planning Board Approval: Request for: Temporary Certifica e Final Certificate: (check one) 5DFee Submitted: $ (4qV Applicant Signature ',dei ®C S®Ut�® Town Hall Annex b ,o l® : Telephone(631)765-1802 54375 Main Road 41 illig Z Fax(631)765-9502 P.O.Box 1179 co, Q A�� ,r ® A roger.richert(a�town.southold.ny.us Southold,NY 11971-0959 , X i e l/TC®UNT i* •al _eS 011 BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION Issued To: Mark Nolan Address: 2000 Harbor Lane City: Cutchogue St: New York Zip: 11935 Building Permit#: 39554 Section' 103 Block: 1 Lot 20.12 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: North Electric License No: 890-ME SITE DETAILS Office Use Only Residential X Indoor Basement Service Only Commerical Outdoor X 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures HID Fixtures Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel NC Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel NC Blower Range Recpt Fluorescent Fixture Pumps Transformer Appliances Dryer Recpt Emergency Fixtures Time Clocks Disconnect Switches Twist Lock Exit Fixtures TVSS Other Equipment: 9.945 kw Photovoltaic System To Include, 39 - TSM 255 PA05 Panels, With M-215-60-2LL Micro Inverters,NC Disconnect Notes: 111 Inspector Signature: = ; - Date: September 30, 2015 Electrical 81 Compliance Form.xls 3953--A-1 Tom Petersen Architects • Plannersr i;) H ;1 ' , Construction Official: Ma '2 2015 ' i Building Department for project at: SEP 3 2015 � / 2000 Harbor Lane Cutchogue,NY 11935 , J r; ; r, in,i 0 Re: Solar Panel Installation—As-built Certification,Permit#BP39554 Nolan Residence 2000 Harbor Lane Cutchogue,NY 11935 Dear Sirs, I've reviewed the as-built solar panel installation at this location to evaluate the existing roof structure and the connection of the panels to the roof. Criteria: Applicable codes: 2010 Residential Code of New York 2001 Wood Frame Construction Manual Design roof load: 30 psf live load, 15 psf dead load,45 psf total load Design wind load: 120 mph,35 psf;Exposure Category `B' My findings are as follows. 1. The new solar panels will imply an additional dead load of 3 psf. The existing roof structure (2x8 roof rafters @ 16"o.c.,with 2x4 collar ties and braces and 2x10 hips and ridge, span= +/- 14'-4"and+/- 18'-2")is sufficient to bear this additional load. This analysis is based on the existing single layer of asphalt shingles but is also adequate for two layers. 2. The solar panels are attached to the roof with the SolarMount-1 rack system by UNIRAC. The rack system,roof connections and connection spacing are rated for 110 mph. This project requires the larger Solar Mount I-2.5 beam(2.5"high)and spacing of flange foot connection to roof at 48"o.c.maximum.Flange footing connections to the rail are not required to be staggered. The flange foot connections to the roof are 5/16"diameter x 4"long lag bolts. The total panel installation is no higher than 6"above the roof plane. It is a violation ofNYSED 7209 for any person, unless acting under the direction of a licensed professional, to alter an item in any way. If an item bearing the seal of a licensed professional is altered, the altering licensed professional must attach the notation `altered by'with his seal, signature, date of alteration, and description of the alteration. I therefore certify that the existing installation complies with the applicable codes and design loads mentioned above,as well as ASCE 7-05 and 2011 NEC(including Article 690),and is acceptable for approval. Please let me know if you have any questions on this information. Thanks! ..c RED SRC S' erely yours, 0 PPF S F• T y/], Tom Petersen + k' N), 4 �'* �552g91 '' Cc: Kelcy Pegler,Roof Diagnostics '� "®"''• ,l�` ``�.` F NFNS, ° 6 Country Lane•Howell,New Jersey 07731•Telephone 732-730-1763,Fax 732-730-1783 . FIELD INSPE QNRE'ORT DATE COMME,N'TS, .r 1.r t r..:\2........_:—. r .t . .. 1 FOUND 1''IoN(1sT) R l . d . . 9w FOUNDATION(2ND) '' ,. , ' . r • 1r U g . ROUGH FRAMIM& • H PLUMBING . • . . . . . ' .. �. _. . _. 1 $. • INSULATION PER.N.Y. • .. ( H STATE ENERGY CODE ' . •. . •' . . - . • . •r • ' 4 ,, err` . .T z , • FINAL 1 J _ ,. 1- .. . . _ . , . • 3 ..IOI`!''ti �+� 'moi ►T5 `""_.. • ,�-- _ 0 f'16},L. C'A•1/4 lis ' '.!.2.. ,. ' ;(, .(: '-' 6).e 't/o 4- • #12-'C... .if:03'4' . ' G/Z1.1,51 �iL< 40 ' i'T. / ir � i. 4R: `( O r r m . 6' z f Y ' TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD,NY 11971 4 sets of Building Plans TEL: (631) 765-1802 Planning Board approval FAX: (631) 765-9502Survey SoutholdTown.NorthFork.net PERMIT NO. Check , Septic Form N.Y.S.D.E.C. Trustees C.O.Application r- Flood Permit Examined o2-a3 ,20 /S Single&Separate Storm-Water Assessment Form Contact: Approved -97f2-- ,� 20 1< Mail to: Disapproved a/c Phone: Expiration -5,2046 - it-lei,e---. ) 3 C E' [ W E / Building Inspector tICATION FOR BUILDING PERMIT _�1: FEB 17 . 2015 Date veimU/4)/ 13 , 20 /.5 PT Dc DEPT INSTRUCTIONS TCIf;OF SOHTHOI D a. his-applicatiorrMUST-be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans,accurate plot plan to scale.Fee according to schedule. b.Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas,and waterways. c.The work covered by this application may not be commenced before issuance of Building Permit. d.Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f.Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date.If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize,in writing,the extension of the permit for an addition six months. Thereafter,a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Depattutent for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York,and other applicable Laws,Ordinances or Regulations,for the construction of buildings,additions,or alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code,ho sing code,and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. (ILL- (ILL-OCCUPANCY OR (Signature of applicant or name,if a corporation) @ @ r '� s I G, ',_;gin- Fm P @ p�O t-te aLd4 01 t l'1 tPe L s m1 _,0i L L., i . 1: g ;'t C u.. (Mailing address of applicant) OF Der!Ur7:3,91vr:v APPROVE art AS a,:,7-^'- ;1 State whether applicant is owner, lessee, agent, architect, engineer, general contrpctor, electryign� umber or builder DATE _* /5BP u_3_...-._._ s. OLAP IiimAcTIg CCC / ,1 -_ ____ `� � NOTIFY BUILDING DEPARTMENT AT Name of owner of premises RAe.� ILA 765 1802 8 AM Tr, 4 PM FOR THE (As on the tafdllL615,11dStIUTIONS. If applicant is a corporation, signature of duly authorized officer 1. FOUNDATION TWO REQUIRED FOR POURED CONCRETE 2 ROUGH-FRAMING,PLUMBING, (Name and title of corporate officer) STRAPPING, ELECTRICAL&CAULKING Builders License No. Dal-LS 3—14 3. INSULATION Plumbers License No. 4 FINAL-CONSTRUCTION &ELECTRICAL Electricians License No. SQ -ME MUST BE COMPLETE FOR C 0 Other Trade's License No. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW 1. Location of land on which proposed work will be done: YORK STATE NOT RESPONSIBLE FOR 7-000 HR$Og. LANE DESIGNLUTCNOC�OE ERRORS House Number Street Hamlet c e), /, County Tax Map No. 1000 Section 10 3 Block / Lot -Z-719042-- Subdivision Filed Map No. Lot 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy me FArLI,Y b. Intended use and occupancy QUO& FAM.tC_`4 3. Nature of work(check which applicable):New Building Addition Alteration Repair Removal Demolition Other Work 501..002.PAt3etS (Description) 4. Estimated Cost 3S O2.Qi Fee (To be paid on filing this application) 5. If dwelling,number of dwelling units Number of dwelling units on each floor If garage, number of cars 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of existing structures, if any: Front Rear Depth Height Number of Stories Dimensions of same structure with alterations or additions: Front Rear Depth Height Number of Stories 8. Dimensions of entire new construction: Front Rear Depth Height Number of Stories 9. Size of lot: Front Rear Depth 10. Date of Purchase Name of Former Owner 11.Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law, ordinance or regulation?YES NO 13. Will lot be re-graded?YES NO Will excess fill be removed from premises?YES NO zoo() NA42652..AtVE 14.Names of Owner of premises Mit t3nLAt\ Address CUT c. tc � Phone No. S(Co• 3)5 .72 5 Name of Architect"WA p rE gSe MAddress 'm LL N3 P-oE e No 732 •7%0' 1163 Name of Contractor NRC71•t OM E.-SbtA R_ Address ?, c e Pone N°o. 69(•77t•' N3 c 1 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO * IF YES, SOUTHOLD TOWN TRUSTEES &D.E.C. PERMITS MAY BQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO * IF YES,D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey,to scale,with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below,must provide topographical datarvey. 18. Are there any covenants and restrictions with respect to this property? * YES NO * IF YES,PROVIDE A COPY. STATE OF NEW YORK) SS: COUNTY OFSbr4ba) eo1\' GSE'p3 being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)He is the 6h1T ACTO -- (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief;and that the work will be performed in the manner set forth in the application filed therewith. 0;:w Swq. to before me this ,,,`' c .07 S1�60 ty ,�/ 1 ia[ 20 (l �b��" p6' L� day of ���'� oto No.0��oasgs0000112.0.�1�o / , Q m� 0,6.° sole EXp Q e Q L._. C Notary Public My Signature of Applicant 00 Ir•fMq•,,`. Scott A. Russell '`,`� °5� � ��_ STORMWATER SUPERVISOR a MANAGEMENT SOUTHOLD TOWN HALL-P.0.-Box 1179 � 53095 Main Road-SOUTHOLD,NEW YORK 11971 � _.�� Town of Southold •••'••..,..,r ,,P CHAPTER 236 - STORMWATER MANAGEMENT WORK SHEET (TO BE COMPLETED BY THE APPLICANT ) DOES THIS PROJECT INVOLVE ANY OF THE FOLLOWING: Yes No (CHECK ALL THAT APPLY) O rI A. Clearing, grubbing, grading or stripping of land which affects more than 5,000 square feet of ground surface. ❑ B. Excavation or filling involving more than 200-cubic yards of material within any parcel or any contiguous area. ❑ C. Site preparation on slopes which exceed 10 feet vertical rise to 100 feet of horizontal distance. ❑ D. Site preparation within 100 feet of wetlands, beach, bluff or coastal erosion hazard area. • ❑ . Site preparation within the one-hundred-year floodplain as depicted on FIRM Map of any watercourse. O 13 F. Installation of new or resurfaced impervious surfaces of 1,000 square -feet or more, unless prior approval of a Stormwater Management Control-Plan was received by the Town and the proposal includes in-kind replacement of impervious surfaces. • .1 * If you answered NO to all of the questions above, STOP! Complete the Applicant section below with your Name, Signature, Contact Information, Date & County Tax Map Number! Chapter 236 does not apply to your project: * If you answered YES to one or,more of the above,please submit Two copies of a Stormwater Management Control Plan and a completed Check List Form to the Building Department with your Building Permit Application. APPLICANT (Property Owner,Design Professional,Agent,Contractor,Other) , S,C.T.M, $: 1Dbtrict0tr Q c /01 Date NAME •/i' ESQ /03 `2 2 it; / OS Section Block Lot ♦V '1, " gn7rr"m '''-- "FOR BUILDING DEP4IRTMENT USE ONLY**** Contact Information. 631 . 11/1 ' W ail (Telephone Numbed /, Reviewed By:C ) /'P 61t-l\--(-01 Date: - 1 7-137 Property Address/Location of Construction Work: MOOHARBOR mit LANE 111 for processing Building Permit. uu Stormwater Management Control-Plan Not Required. CUTCHOcIVE NI 11935 0 Stormwater Management Control Plan is Required. (Forward to Engineering Department-for Review.) FORM # SMCP-TOS MAY 2014 - - ' - - - - - ,614 e Town Hall Annex , ` � � • * Telephone Telephone(631)7654802 54375 Main Road (631)765Q P.O.Box 1179 � Q /i rocer.richertaialo o .nv.us Southold,NY 11971-0959 ``� 't1 BUILDING DEPARTMENT TOWN OF SOUTHOLD APPLICATION FOR ELECTRICAL INSPECTION REQUESTED BY: =OAR, Row Eat.E Date: 2113115 Company Name: ,NRCa RoptE SOS IJORIVk aecrizTC LLC (.Et.EcfetlulN� Name: 3bsePit P. STRT.Amo License No.: Address: SOC. ROCKq Po -'IAPHANtt, IbAb)Skocgt vqr • Phone No.: 423 •184•i44044 !! IW U11 • JOBSITE INFORMATION: (*Indicates required information) *Name:OWNER) MARK NOLAtJ *Address: 2000 RARsoz, LANE CuTCKOGZoe• *Cross Street: WA • *Phone No.: 51i, • 3 X5. 72615 Permit No.: Tax.Map District: - 1000 Section: /OS - Block: 1 Lot: /2 .OO'Z. *BRIEF DESCRIPTION OF WORK(Please Print Clearly) TA/ S'TA udi rl01'V D p" nor M ou'rep SOLAR Et.ecrp c (Please Circle All That Apply) • is job ready for inspection: YES t NO Rough In Final *Do-you need a Temp Certificate: YES I NO Temp Information(If needed) *Service Size: 1 Phase 3Phase 100 150 200 300 350 400 Other *New Service: Re-connect Underground Number of Meters Change of Service Overhead Additional Information: PAYMENT DUE WITH APPLICATION 82=Request for Inspection Form ,. . ..,.._. ,. ..„.. _ \03 - I, _pc, it .2 TOWN OF SOUTHOLD PROPERTY RECORD CARD 6( . OWNER STREET a 000f VILLAGE - DIST. SUB LOT i Kan 4 V e rs-hae L, -4)ian Hb -arc -0. - Lie. r, -(,2 CI<-)cie-IC?.. 9 11 V<.1 6.'tr- 7- R4'Y L ('-i 0)-(46=-. ACR. REMARKS .A thilV+PCA L- 1 ° 9o) Oliver( TYPE OF BLD. j /. ..,>— ÷..;----7,- .-- PROP. CLASS 6 i c he-- Co7. )i) F,x , LAND IMP. TOTAL DATE G-Xz7r.'-: eo P4 45 -2'7,-,vl\14' ), -,- .‘J! 1C-c--.).‘ s/. 7-4) /(4i/.9..!.7 4 7)4&-1 . 1. 141a0 loci-zoiale-t- 650) -lb Dir- 475o' OC3 i /8 00 .74.e/a00 , 8°D I io optt , .1--_-_,„ 31 , 127 7-7 pa I L.ff-o „.< _-70 ? - coiosi- one-iza,,v1,1; ii i)c,othilc, 2000-- .Th/ (c300 e cc, ,/ / Va9/9i /zp 4/06— Swi cc f t 2 /Qf75 ee)./0 / — %SOO 750 i) 7---, -i,1 5 a," ' ____--------- laN , , — 77-0f) c/. /71,0 1 "J/0-5 e 6c?//O -7,216o 2_ 000 . [ 63)00 , o / 30 0 44704 //1-51/3—/-/Z-7263,a2`//- 0/ iv e i 4-a AMIao $ 520 ee L-v g 000 / 0000,z 2_/41 Ili. vg//-2., - 60,- . ',97fr5v - /4e,/23//4/'---C3C / 3/q- 6e200 FRONTAGE ON WATER TILLABLE FRONTAGE ON ROAD WOODLAND I ' DEPTH MEADOWLAND t BULKHEAD HOUSE/LOT TOTAL , 2_015:(g-lh 17- 1 , g _ _ '7 i C� `it5�p JlIr ; : •,:R � �. . . .. �ne 1N g'` z.-•N 1� -rGf,'t,wFA. ` l T/_L '`a , . k, G. � ir - S • ill _ •• ...IN.. _..,i� t _i 1 *r` 5�,, illrI11= ti :l1. ill Yr pj+ . . ..+ Y .1 ,,,,e;...14., r.}'r ti t T.t wr t ` �n is � . v -`' l� I4", "`" rttt7a+,i- ,.., m, w" g °° ,� ti ,..,172:-,,,,,,,,k i ;Ve-ist. , ' ;-..,--:!-.._'-',-.t - y _ •;-. a- , : ''{{Tw• � ; ✓4•�,,, fIF , •{ F.. F h x ,F; •_.. `:.,;' =c�'rti\,-i._r',,.c,:``•--:'::"..,,,.,i 17 1 Ncy R. ,f :4t,"rt.at. 7a` rnet`.5... 103.-1-20.12 3/10 I - ! M. Bldg {{f2 i� �� (0 f-`C- �' ,�p'7� Foundation -� Bath �r Dinette \ST� -!-C. 1 s { I - .x'41 FULL,' Extension t"7 X 3 Basement �RA`wL Floors Kit ,I." SLAB _ Extension Ext. Walls �\ � ( I.ka Interior Finish s1 L R V l' t4, 3X3 =c1 - to`({C7 :?- q(@ { So '3 3 7 Flre Place '1 Nr‘:.*- -,- ( \ Heat �5 D R ExtensionJ z �X ti+Y � � tfp Woodstove BR. 3P3 `7(1 {ee Pk105 � ' . j p —.j Porch�? 4 Y T �� h 303 .� ..-2-..1-15 , Dormer , Fin B. -- 2 5 ' 7 i3--�! ,k. 15 X 1.5- zZs/ --.7-7 -- �——_- Attic ____2,..4,4,_=-1,,,----24,-- _ -- 7(13 /5 — f--ev- PIeais p 3 ZS 3 70 Rooms 1st Floor ' Garage �z x22_ = 11-S11-. lz� (005- Driveway Rooms 2nd Floor o.B.- 4(�� g X D AJC, Pool 7/13 1 o ac`l -Poco{ SPO/ DCl — a�ob( .1 (1J) - est- 20o ? 7 6 9 7-//4 ioacl (—F--11'14:7;;\'' i211'74../- Acc•RO® CERTIFICATE OF LIABILITY INSURANCE DATE(MMIDD/YYYY) 12/05/2014 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND,EXTEND OR ALTERTHE COVERAGE AFFORDED BYTHE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED • REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT Danielle Butterfield MCGRIFF,SEIBELS&WILLIAMS,INC - NAME: PO.Box 10265 (NC NN.Ext):800-476-2211 FAX No)• Birmingham,AL 35202 EMAIL ADDRESS:dbutterfield me9 riff corn INSURER(S)AFFORDING COVERAGE NAIC# INSURER A:Scottsdale Insurance Company 41297 INSURED INSURER B:Liberty Mutual Fire Insurance Company 23035_ Roof Diagnostic Solar Holdings,LLC Roof Diagnostics Solar&Electric of NY,LLC dba NRG Home Solar INSURER C Federal Insurance Company 20281 614 Corporate Way Suite 4 Valley Cottage,NY 10989 INSURER D•Navigators Specialty Insurance Company 36056 INSURER E INSURER F• COVERAGES CERTIFICATE NUMBER:FNFXDPLK REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. /LTR TYPE OF INSURANCE NW SR SUER POLICY EFF POLICY EXP VD POLICY NUMBER (MMIDD/YYYY) (MM/DD/YYYY) LIMITS A GENERAL LIABILITY 102590435C 08/04/2014 07/01/2015 EACH OCCURRENCE $ 2,000,000 • DAMAGE TO RENTED X COMMERCIAL GENERAL LIABILITY PREMISES(Ea occurrence) $ 100,000 CLAIMS-MADE n OCCUR MED EXP(Any one person) $ excluded _ PERSONAL&ADV INJURY $ 2,000,000 GENERAL AGGREGATE $ 4,000,000 GEN'L AGGREGATE LIMIT APPLIES PER PRODUCTS-COMP/OP AGG $ 4,000,000 —1 POLICY X PRO- LOC $ JECT B AUTOMOBILE LIABILITY AS2Z91462454014 04/29/2014 04/29/2015 COMBINED SINGLE LIMIT 1,000,000 (Ea accident) $ X ANY AUTO BODILY INJURY(Per person) $ ALL OWNED SCHEDULED BODILY INJURY(Per accident) $ AUTOS AUTOS X HIRED AUTOS X AUT WNED PROPERTYPri a ent) DAMAGE Sc d Deductible: Comp/Coll $1,000 D UMBRELLA LIAB X OCCUR ELU782570/01/2015 08/04/2014 07/01/2015 EACH OCCURRENCE $ 5,000,000 X EXCESS LIAB CLAIMS-MADE AGGREGATE $ 5,000,000 DED RETENTION$ _ $ C WORKERS COMPENSATION 00447277940000 07/01/2014 07/01/2015 X TAT TORY - T AND EMPLOYERS'LIABILITYER ANY PROPRIETOR/PARTNER/EXECUTIVE Y/N E L EACH ACCIDENT $ 1,000,000 OFFICER/MEMBER EXCLUDED? N/A (Mandatory in NH) E L.DISEASE-EA EMPLOYEE $ 1,000,000 If yes,describe under 1,000,000 DESCRIPTION OF OPERATIONS below E L DISEASE-POLICY LIMIT $ S DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES (Attach ACORD 101,Additional Remarks Schedule,if more space is required) Certificate Holder is Additional Insured under General Liability as required by written contract CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF,NOTICE WILL BE DELIVERED IN Town of Southold ACCORDANCE WITH THE POLICY PROVISIONS. Building Department, Town Hall Annex Building 54375 Route 25 AUTHORIZED REPRESENTATIVE P.O.Box 1179 ` �4 Southold,NY 11971 \lt4�er4! �•��as Page 1 of 1 ©1988-2010 ACORD CORPORATION. All rights reserved. ACORD 25(2010105) The ACORD name and logo are registered marks of ACORD ‘ ' to'r - SUFFOLK COUNTY_ „ LICENSING& CE CONsUMER AFFAIRS 4. ,E1.ECTRIolAN -- -40SEPH P STRIANObearer: - the US'YE3S- ruaie- Ei.E9TR10, , • by NORTULLc County ; 890-IWE :12/01/1975 • STATE OF NEW YORK WORKERS'COMPENSATION BOARD CERTIFICATE OF INSURA/NTCE COVERAGE UNDER THE NYS DISABILITY BENEFITS LAW PART 1., To be completed by Disability Benefits Carrieror-licensed Insurance Agent of that Carrier la, Legal Name and Address Of Insured(Use street address only) lb.Business Telephone Ntunber of Insured ROOF DIAGNOSTICS SOLAR AND (800) 757-6527 ELECTRIC OF NY LLC 1c.NYS Uneniplo3rment Insurance Employer Registration dba NRG HOME SOLAR Niiiitber of Insured 614 CORPORATE WAY VALLEY COTTAGE, NY 10989 Id,Federal Employer Identification Number of Instated or Social Security Ntenlbet 454-17-5140 2. Name and Address of the Entity Requesting Proof of 3a,Name of Insurance Carrier Coverage(Entity Being Listed as the Certificate Holder) NEW YORK STATE INSURANCE FUND Town of Southold Building Department • Building 54375 Route 25 3b.Policy Number of entity listed in box"la": P.O. Box 1179 DBL 6523 96 - 4 Southold, NY 11971 3c policy effective period: 08/07/2014tq 08/07/2015 4.Policy covers:, a.E All of the employer's employees eligible under the New York Disability Benefits Law b.® Only the following Cass or:classes of the employees employees: Under penalty ofperj ury,,I certify that I ant an authorized representative or licensed agent of the insurance eanier referenced above and that the named insured has NYS Disability Benefits insurance coverage as described above. Date Signed 12/5/2014 By "' J oseph J ,Mast_ l5igretuse of insure rice rner's authorized replesertatrue of WS liae'reed i'sura ice&gierrt oflthat ireurerine ra rrieri Telephone liumber (866) 697-4332 Title Director of Disability.Benefits Insurance IMPORTANT: Ifbox"-la"is checked,and this form is signed by die insurance carrier's authorized representative or NYS Licensed Imex ace Agent of that caatrier,this certificate is COMtPLETE. :Mil it directly to lire certificate holder. If boa"°,111-is checked.this ceniifkcate is NOT COMPLETE for purposes of Section 220.Sub I.S oldie Disability Benefits Law. It must be mailed for completion to the Werkers,Compensation Board.DB Plans Acceptance Unit.20 Park Street.Albvlrty,New York 12207. PART T.To be completed by NYS Workers'Compensation Board(Only if box"4b"of Part t has been checked) State-Of New York Workers'Compensation Board According to information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS Disability Benefits Law with respect to all of hisrber employees. Date Signed ----_..__ ----- By__..__- _—__-- (SiSsttture of NYS Wailers`Compensation Board Employee) Telephone Number Title Please Note:Only insurance caniers licensed to write NYS disability benefits insurance policies and NYS licensed insurance agents of- those insurance carriers are authonzed to issue Foran DB-120,1. Insurance brokers,are NOT authorized to issue this form. DB-120.1(546) Certificate Number 298903 STATE OF NEW YORK WORKERS'COMPENSATION BOARD CERTIFICATE OF NYS WORKERS' COMPENSATION INSURANCE COVERAGE la. Legal Name&Address of Insured(Use street address lb. Business Telephone Number of Insured only) 800-757-6527 Roof Diagnostics Solar&Electric of NY lc. NYS Unemployment Insurance Employer Registration 614 Corporate Way,St 4 Number of Insured Valley Cottage,NY 10989 50-39533-4 ld. Federal Employer Identification Number of Insured or Work Location of Insured (Only required if coverage is Social Security Number specifically limited to certain locations in New York State, 454175170 i.e.,a Wrap-Up Policy) 2. Name and Address of the Entity Requesting Proof of 3a. Name of Insurance Carrier Coverage(Entity Being Listed as the Certificate Holder) Federal Insurance Company Town of Southold Building Department 3b. Policy Number of entity listed in box"la" Town Hall Annex Building 54375 004 4727794 00 Route 25 3c. Policy effective period PO Box 1179 Southold NY 11971 07/01/2014 to 07/01/2015 3d. The Proprietor,Partners or Executive Officers are X included(Only check box if all partners/officers included) ❑ all excluded or certain partners/officers excluded This certifies that the insurance carrier indicated above in box "3" insures the business referenced above in box "la" for workers' compensation under the New York State Workers' Compensation Law. (To use this form,New York(NY)must be listed under Item 3A on the INFORMATION PAGE of the workers'compensation insurance policy.) The Insurance Carrier or its licensed agent will send this Certificate of Insurance to the entity listed above as the certificate holder in box"2". The Insurance Carrier will also notify the above certificate holder within 10 days IF a policy is canceled due to nonpayment of premiums or within 30 days IF there are reasons than nonpayment of premiums that cancel the policy or eliminate the insured from the coverage indicated on this Certificate. (These notice may be sent by regular mail.) Otherwise, this Certificate is valid for one year after this form is approved by the insurance carrier or its licensed agent, or until the policy expiration date listed in box"3c",whichever is earlier. Please Note: Upon the cancellation of the workers' compensation policy indicated on this form,if the business continues to be named on a permit, license, or contract issued by a certificate holder,the business must provide that certificate holder with a new Certificate of Workers' Compensation Coverage or other authorized proof that the business is complying with the mandatory coverage requirements of the New York State Workers'Compensation Law. Under penalty of perjury, I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has the coverage as depicted on this form. Approved by: Ronald B.Giadrosich.McGriff,Seibels&Williams Inc.(Executive Vice President) (Print name of authorized representative or licensed agent of insurance carrier) 12/5/14 Approved by: (Signature) - (Date) Telephone Number of authorized representative or licensed agent of insurance carrier: (205)581-9415 Please Note: Only insurance carriers and their licensed agents are authorized to issue Form C-105.2 Insurance brokers are NOT authorized to issue it. C-105.2(9-07) tq-1 O/20.1 U IU a ap Home 170 Wilbur Place,Suite 100.Bohemia,NY 11716 1-800-75-SOLAR Inge SOLAR February 13, 2015 Solar Panel Installation • Nolan Residence 2000 Harbor Lane Cutchogue, NY 11935 Dear Sir/Madam: Please find the following attached documents for the Nolan Solar Photovoltaic Installation at 2000 Harbor Lane Cutchogue, NY: • Check made payable to the Town of Southold for the fee of$200 • Southold Building Permit Application • Application for Certificate of Occupancy • Application for Electrical Inspection • Stormwater Management Worksheet • Four (4) Sets of stamped and sealed architectural plans with spec sheets • Roof Diagnostics Solar's Insurance Information, including Workers Comp,Disability,&Liability documents. • Copy of ME License Please do not hesitate to contact me with any questions or concerns. I can be reached at 631-416-5525. Sincerely, Jaime Coltman Permitting Specialist NRGHomeSolar.com Tom Petersen Architects • Planners Construction Official: February 6,2015 Building Department for project at: 2000 Harbor Lane Cutchogue,NY 11935 Re: Solar Panel Installation Nolan Residence 2000 Harbor Lane Cutchogue,NY 11935 Dear Sirs, I've reviewed the proposed solar panel installation at this location to evaluate the existing roof structure and the connection of the panels to the roof Criteria: Applicable codes: 2010 Residential Code of New York 2001 Wood Frame Construction Manual Design roof load: 30 psf live load, 15 psf dead load,45 psf total load Design wind load: 120 mph,35 psf My fmdings are as follows. 1. The new solar panels will imply an additional dead load of 3 psf. The existing roof structure (2x8 roof rafters @ 16"o.c.,with 2x4 collar ties and braces and 2x10 hips and ridge,span= +/- 14'-4"and+/- 18'-2")is sufficient to bear this additional load. This analysis is based on the existing single layer of asphalt shingles but is also adequate for two layers. 2. The solar panels are attached to the roof with the SolarMount-1 rack system by UNIRAC. The rack system,roof connections and connection spacing are rated for 110 mph. This project requires the larger Solar Mount 1-2.5 beam(2.5"high)and spacing of flange foot connection to roof at 48"o.c.maximum.Flange footing connections to the rail are not required to be staggered. The flange foot connections to the roof are 5/16"diameter x 4"long lag bolts.The total panel installation is no higher than 6"above the roof plane. It is a violation ofNYSED 7209 for any person, unless acting under the direction of a licensed professional, to alter an item in any way. If an item bearing the seal of a licensed professional is altered, the altering licensed professional must attach the notation `altered by'with his seal, signature, date of alteration, and description of the alteration. I therefore certify that this installation complies with the applicable codes and design loads mentioned above,as well as ASCE 7-05 and 2011 NEC(including Article 690),and is acceptable for approval. Please let me know if you have any questions on this information. Thanks! ��FtED ARS, Sin rely yours, �0 fps TF tP C� ��� A, gyp, v/ ti (AiPIMF ✓ \ti4 fns �1 I► I Tom Petersen 'arQtraes Cc: Kelcy Pegler,Roof Diagnostics '9j► 035290 4 d %OF Ne`N 6 Country Lane•Howell,New Jersey 07731 •Telephone 732-730-1763,Fax 732-730-1783 PROJECT DESCRIPTION: SHEET INDEX PROJECT SITE � •q° PV-1 SITE PLAN &VICINITY MAP r .4 nrgo 39x255W ROOF MOUNTED SOLAR PV-2 ROOF PLAN &PANELS , S--.4s:is' i"; r?'• 'i'"t"'+. �I _`� PHOTOVOLTAIC MODULES n rl..rrdea;- ": !'. ., 1I�' �' PV-3 ROOF ATTACHMENT DETAILS Ian r •,;. SYSTEM SIZE: 9.945 kW DC STC PV-3,1 ELEVATION Ar,'v, °+ _ 5;t-' �z` ,:„,,t,,,...., '` b ARRAY AREA PV-4 • ELECTRIC UNE DIAGRAM '_1 Sh7't:'r"iG1g°tr ititen ,y -- 34=1"", r '.' �q r� (Roof#1): 193.71 R' PV-5 LABEUNG Ee xu: 1 a it«. ant ...7.„1.54'43''''.1-7---1,-..' ""F' 1 �`°( �.b 11 (Roof #2): 493.08 fP PV-6 INVERTER CUT SHEET 1 ,'' r41_(,ev� `.5 '' N) T,>iP...4?r�:sID41', `''�- ROOF PV-7 ENGAGE CABLE CUT SHEET , PV-9 SOLARMODMODULE UT T SCUT HEET SHEET „'cgc:a, ,ar' ) DIAGNOSTICS PV-10 ATTACHMENT PV-CUT SHEET r a+ra`etr1 ° ''.-` I PV-11 PRODUCTION METER CUT SHEET , "«J3ratt r l , • SOLAR AND rELECTRIC.LL D / \ P , r License No. «.. :—J al ,�`E�:r,i �i.aZ�'err :II.- `OOOit�igteCONTRACTOR'S SIGN: 1 y :' -.)001 ea;+t .;r« : . r:an5:a `; " '"; : oa.rePo aArc W'etw90 1 • y • -1 „ 4..: ) : Y / /. i ry1 n Ccr:ort '-Na/:::,7--"----,.-; , ^r -a. .y ` �', ~ r-. . ,.-iti� MNa* rLCT' ,Sh71t•T 's {e eOFCOS ' -Z,: (E) UTILITY METER / r (EXTERIOR POLE) / C .- . :-` V I (E) MAIN SERVICE PANEL . (INTERIOR WALL) Z VICINITY MAP 0 N Ili (E) CHIMNEY(TYP.) \ R 11 Trina Solar PV-1 SCALE:NTS Z LLI c4"3 N o (TSM-255PA05.08) in W Z _ r. E, ROOF MOUNTING PLANES w Q g>- o .s � o; fx Z M p / `�• EXISTING' \ ,. , . } L• ¢ (n Do UJ m co+� r,�, DRIVEWAY w Q C'1 To ,..s...., ss„,,... •s. ti m 7+ uy^ ^Sar-. ,'3 N= w Z • 28 Trina Solar r 4, h ] , ,_ r, 1 U H (TSM-255PA05.08) • v: .v " tf„;•1 O Z 1 STORY ROOF #2 p g ` ���••”. c .t r ",i ,) ,t,`. ;w : ----\ • HOUSE 1;� .� �r'aytt "3 sit . ,„ . S.y' 1 1 i iy Ya +r Drawing No.: 7295 L_. fir^ �'u,a �� e�i8� �. ' �r- T"-:—• .r .. s y v‘,,,, ,�3.,'',,/i., p ,L Drawn By: DE1#� �', 14;' r , f` pc a ' k .. Rev.By: i. 1 ' �u '4 .••••'1 •'' Dale: 27 Jen 2015 ,r a * r SHEET SIZE: 1"_,l'"it • *,A ,', „ ' ANSI B - ;, 11"x17" PIAN ,,P- all, `E. ,>-�.., ,t.`„ ., -''d TITLE SHEET. NORTH - SITE PLAN& 1 SITE PLAN WITH ROOF PLAN 3 HOUSE PHOTO VICINITY MAP PV-I SCALE: 1/64°=1'-0° PV-1 `,f' SCALE:NTS PV-1 )16 1' ARRAY & ROOF AREA CALC'S ROOF #1 nig. ARRAY AREA = 193.71 ft°. E) UTILITY METER ROOF FACE AREA = 302.56 ft'. (EXTERIOR POLE) �I�' ' I� 193.71/302.56 = 64% OF ROOF t� FACE AREA COVERED BY ARRAY (N) TRENCH---.—___________25; SOLAR ARRAY & ROOF AREA CALC'S ROOF #2 (E) MAIN SERVICE PANEL �I (N) UTILITY AC DISCONNECT ROOF (INTERIOR WALL) (EXTERIOR WALL) ARRAY AREA = 493.08 ft'. (N) AC DISCONNECT 1t1 (N) L-GATE 120 PV PRODUCTION METER DIAGNOSTICS ROOF FACE AREA = 671.82 ft'. (INTERIOR WALL ' (EXTERIOR WALL) SOLAR AND ELECTRIC,LLC 493.08/671.82 = 73% OF ROOF , t (N) PV LOAD CENTER «,. License No.- FACE AREA COVERED BY ARRAY - (EXTERIOR WALL) CONTRACTORS SIGN: ROOF DESCRIPTION g�esaw4:4, COMP. SHINGLE - e�,.°J„ 0: PITCH (R1)- 24' r1 *IA * _ll', . * AZIMUTH (R1)- 168' t � o a SHADING (R1)- 97% ��� 'N'OF'r1e'a{e PITCH (R2)- 15' AZIMUTH (R2)- 168' 3" 5'-4" 11 SHADING (R2)- 92% 10'-11" r� t 3" t1 (E) CHIMENY (TYP.) r1,� - 1. I f ° UNIRAC SOLAR 4„ r__ - "- • ° � 10)/"\ �p 4 'IP " III N MOUNT RAIL(TYP.) 3'-3" - 9'- iire-.,,, i- . a a Z M u2 os' a: - w rn rn NENPHASE MICROINVERTERS r'- ..., - fl"' . - W Z n o M-215-60-2LL-S22-IG (TYP.) �a U S Q °O-- 'd W Q g} � O 11 Trina Solar 3" d ,. 1� o Z el o (TSM-255PA05.08) o W m LI,I e M cm ::v a.o _,_QoY sP7 F = o ROOF (J1Ilk dJ' w CL Q O v o 1'-3" --,[3:.- -t7. ° • a Es Z 0 0 Z o App °QF<� _J NU , Z (N) JUNCTION BOX 5" �� Z a� 4" D_ 140 ATTACHMENTS @ 48" 3'-3" ‘....---------21'-11" .,•_21'-11" Q 0. C. MAX. (TYP.) 1y„ 5" 28 Trina Solar (TSM-255-205,08) Drawing.No.: 7295 Drown By. DB ROOF #2 Rev By: •• Dale. LEGEND --I 39.05"r-- SHEETS27I2JanE: 2015 Ei ENPHASE MICROINVERTERS F ANSI B S22-IG ROOF ATTACHMENT 64.95" 11"x 17" PLANTITLE SHEET' NORTH RAFTERS I 1 SITE PLAN WITH ROOF PLAN CONDUIT ROOF PLAN& PV-2 SCALE:3/32"=1'-0" 401 Q ELECTRICAL EQUIPMENT TSMNE -258 PANELS PANELS-255w Trina Solar PV-2 /i. (/f t nrg Home SOLAR ROOF DIAGNOSTICS SOLAR AND ELECTRIC,LLC License No.-**** CONTRACTOR'S SIGN: a g), ...Ev'Po 6_<cc .---- - ----------X ,-� *�'IF. 'i * PV MODULE * ,'- RAIL 1WITH CO FASTEN N�e'"°x 'QrGROUND WEER & °j of,31� l \ L-FOOT ��� MODULE CLAMPYN5/16" EPOM BONDED PV MODULE /� } \ 304-18,8 SS WASHER COMP SHINGLES /�'' / L-102-3" BRACKET* (OTHER- % ✓ GREEN FASTEN FLASHING: /�,.-� OPTIONS AVAILABLE) / ��� ECO-CP-SQ SQ C MPRES ON BRACKET W N GF-1 FLASHING ,--`�/ V N o /�- ` _ — — 1� �' 5/16°x4"S.S. LAG BOLT WITH 2.5" W Zs- ti o // — G MINIMUM PENETRATION SEALED WITH 0 g- ' I �I APPROVED SEALANT CC IX z 01 o LAG BOLT 5/16° (TO BE VERIFIED) CI) o 14. (TO BE VERIFIED) < V,J m= Co`c �✓ F-� W V \ \_i a =o \ / a o z o 0 N ;. / 0N0I— \ a"r Z Q — — Drawing.No.: 7295 Drawn By DB Rev.By. "* Dale: 27 Jan 2015 SHEET SIZE: ANSI B 11"x 17" TITLE SHEET' 1 ATTACHMENT DETAIL A. ATTACHMENT PV-3 SCALE: NTS Ilft I PV-3 n Home SOLAR ROOF 15. DIAGNOSTICS 1__. SOLAR AND ELECTRIC,LLC License No,-••' CONTRACTORS SIGN' .:: c ero�ia o`c'n Fns m (E) VENT �r_T ;,.p��3 �V. (E) CHIMNEY * Ve * (N) PV MODULES N�'�Or;,s,84e ROOF#2 6 w . 7 ., E2 --- --------------------- _ z w ....... -' -. N O O O D Z `n N 0 Z C71-71— CD c7� bi W Z- ti O O /. I ^Ir �� w �} — 1 e o Z M O 1 CD o - I '' IQII jll' o W 0= c 10 �\ m `�° 1 (0 \ ALI w W Qd vo L �� II�, (E) UTILITY METER a =4 c c �T I (EXTERIOR POLE) a Z o U Z cm FROM UTILITY PROVIDER Q N= c (UNDER GROUND) ��!! V L Z (E) DOOR Z (N) TRENCHZ 0 (E) WINDOW (E) TO MAIN SERVICE PANEL (INTERIOR WALL) (N) UTILITY AC DISCONNECT Drawing No. 7295 (EXTERIOR WALL) Drawn By: DB (N) UTILITY AC DISCONNECT Rev By: (EXTERIOR WALL) Date: 27 Jan 2015 (N) L-GATE 120PV PRODUCTION METER SHEET SIZE: (EXTERIOR WALL) ANSI B (N) 100AMP PV LOAD CENTER 11"x 17" (EXTERIOR WALL) TITLE SHEET' (N) JUNCTION BOX FOR, VOY 2 1 ELEVATION DETAIL FROM PV ARRAY A , ELEVATION P/-3.1 SCALE: 1/B"= 1.-0" ��'l I PV-3.1 I SERVICE INFO INVERTER SPECS MODULES SPECS nb UTILITY COMPANY: PSEGLI INVERTER TYPE: ENPHASE QTY: 39 F1®re MAIN SERVICE VOLTAGE: 240V M215-60-2LL-S22-IG MODULE TYPE: TSM-255PA05.08 MAIN PANEL BRAND: CUTLER HAMMER MY: 39 WATTAGE: 255W MAIN SERVICE PANEL: 200A WATTAGE: 190-270W NOCT WATTAGE: 184W SOLAR SERVICE VOLTAGE: 240V MAIN CIRCUIT BREAKER RATING: 200A CEC EFFICIENCY: 96.5% FRAME THICKNESS: 35MM ROOF MAIN SERVICE LOCATION: EAST i FRAME COLOR: BLACK SERVICE FEED TYPE: FROM UNDERGROUND Voc: 37.7 DIAGNOSTICS `MAIN SERVICE PANEL GROUND: EXISTING GEC ROD / \. Vpmax: 30.5 l SOLAR AND ELECTRIC,LLC License No..r-c:::: (E1 MAN SERVICE PANEL 200A �� MM FUSED CONTRACSIGN' AO 3-JUNC110N BOXES (U)MM METER RATED BUS BAR tOM SOME ONLY DISCONNECT 45 AVP DISCONNECT 45 AVP L-GATE 120 PY CENTER JUNCnON BOX Bl I -L-GATE 120 PVPRODUCTION METER F. SUPPLY SIDE TAP (�P O EFUSES DRISES ©PRo PRODUCTION AEfER^ 11.10A0 w� © T BRANCH #1 �eaEo^qC N) T. neme _ `AAA' 1----- +PE E ger I- 150 2P OIONLY NLAR RLOAD CENTER °�° r ` 10'.* °° 1 / " 1 MN I � �'�',.; • "�_°=� 2-20A/2P SOLAR BREAKER (q DOA Mwu r TO UIILnY (N)1'PVC/EMT CONDUIT U (CONDUIT —( �CAGE NOW=nm MX=R8n Nm agrF os•nEm+ae 1- 15/IP MONITOR BREAKER (r_ I oAla1415-6D-711-54.40 D❑ 1-60A RP(FUSED)AC DISCONNECT " SOIM ARRAY(9.945 Wotel '_' 0 BRANCH #2 EO_CLQC J �, © Kt rN� II MODULES IN PARALLEL CONNECTED BRANCH CIRCUIT (� 11 MODULES ON ROOF+1 yj���j� �- ❑E 1-BOA(FUSED)AC DISCONNECT =•g H 1 14 MODULES IN PARALLEL CONNECTED BRANCH CIRCUIT L(N)I'PVC/fMT _(N)ENGAGE Y U p ® 1-200A MAIN SERVICE PANEL 14 NODULES ON ROOF#2 CONDUIT CABLE OPIUMY0°on-of-sn-o Z M N 1-3/4'GROUND ROD 14 BRANCH IN PARALLEL.CONNECTED BRANCH CIRCUIT p BRANCH #3 W Z n o 14 NODULES ON ROOF+2 2oV>a K. N Q 3 r- �2 p K- w _ �- `' y(E)MOO IY 0 ,A 'A , , " i o - Et Z O, eS NOTES: - E --t, I- ma j Q O Lis co 1) All modules will be grounded in accordance with code and the _(N)T•PVC/DIT _(N)ENGAGE ww ,mu I w/ n v e manufacturer's installation instructions. liy1P CONDUIT p CABLE PPM%Yas-eo-az-ru-10 w LL Q O " o 2) All pv equipment shall be listed by a recognized O o 2 tested lab. L. I—Q MONITORING a Z o U Z 3) Notify serving utility before activation of pv system. ' _ OUTLET g N 0 J 0 4) When a backfed breaker is the method of utility (N)s/4"Pvc/EMTO U f- Z interconnection, breaker shall not read line and load. CONDUR N1 5) When a backfed breaker is the method of utilityZ Q interconnection, the breaker shall be installed at the opposite end of the bus bar of the Main Breaker. 0 0 0 0 0 0 0 6) Work clearances around electrical equipment will be maintained per NEC 110.26(a)(1), 110.26(0)(2) & 110.26(o)(3) 3 1I2 THWN-2 3 B12 THWN-2 Drawing.No.. 7295 7) All exterior conduits, fittings and boxes shall be 3/1z 111641-2 3 Re 11IwN-2 3 Re THWN-2 3 TIO THWN-2 1 012 THWN-2 EGC 3#10 1HWN-2 I #12 THwN-2 BOC Drawn By: DB rain tight and approved for used In wet locations per 1 18 THWN-2 ECC/CEC 1 fe 1HWR-2 ECC/CEC 1 18 THAN-2 EGC/GEC 1 le OEC 1 fe 1104N-2 EGC/GEC 1 fe GEC Roy.By: •• NEC 314,15. Yoe.249vac Von.240VAC Voc:240VAC Vac.24s000 Vac:240VAC Von:240VAC 8) All metallic raceways and equipment shall be bonded and Date: 27 Jan: 2015 yl J enc:J5.1MC enc:35.IMC � " ane;12eMC _Aim;12.8PAC J ,r lac.B.9AAC Thr.9.9AAC � , SHEET SIZE: electrically continuous. ENPHASE INVERTER BRANCH CALCS ENPHASE INVERTER BRANCH CALCS ENPHASE INVERTER BRANCH CALCS ' OTY: 39 MAX AC: 43.875A 01Y: 14 MAX AC: 15.75A DIY: 11 MAX AC: 12.375A ANSI B 00 Y«) NOC: 0.9 1500a .125 NOC: 0,9 (Gn.Imo.La NOC: 0.9 Eon o AaO.1.23 1 1"X 17" WIRE GAUGE: �6 WIRE OCP: 53.25A WIRE GAUGE: 1Y �� WIRE OCP: OO 0 WIRE GAUGE: WIRE OCP: 0 0 TITLE SHEET: xm MM" .mw DE-905 MIP was.TOM of-1111 NM POMO.AYR DE-RIA TEMP RATING: 90'c _ TEMP RATING: 90'c 21.5 28.4A TEMP RATING: 90'c 21''" 28''` ELECTRIC LINE 07 TT AMP RATING: 75A 1TOWtCCP MR AMP RATING: 0 40 "" mt Avato rror,,c'op AMP RATING: Cl) 40 wx44Zggip 6.002sa Ton DIAGRAM TEMP DE-RATE:0.71 APROM°70"M6 TEMP DE-RATE:0 71 TEMP DE-RATE:0.71 PV-4 O. ; TO BE INSTALLED ON THE FACE OF THE TO BE INSTALLED AT MAIN nrg. SERVICE METER PANEL PER NEC 2011 SERVICE PANEL AND UTILITY NET METER: 705.10 �Io 4 ` j' WAR LING, ' ` DU't PUWER$®rGES SEG®N®SORGA-iitgigviNtra x` O-TQVO ...CF yi R -3 /Ir,Af r� S-„UijRC qty Sr%,.,, B 1q,:gro -4 ROOF x 42 VOLTS a DIAGNOSTICS ;1ry�„C4"g, 87tj. Itiaj sw SOLAR AND ELECTRIC,LLC License No.-•"• CONTRACTOR'S SIGN, DISCONNECTION MEANS; TO BE INSTALLED ATowfifiRPor°tir ALL AC DISCONNECTS PER NEC 2011 690.14(C)(2) °° t, • Afft # .9t eae2afi fop S+01 ”AC DISC#® NEplz.. DISCONNECTING MEANS MAY BE ENERGIZED IN THE OPEN POSITION; TO BE INSTALLED AT DISCONNECTING MEANS PER NEC 2011 LU cv 690.17 0 o Z A m N t 7%,;4,S,,. wARNi7 G `. - LU Z n 8 aELECTR C SH,GJCK HAZARD .1 W 0 g '- r o LDO NCOIJCt TERMINALS} N` - 'r'' o � OZ � TER5rNAIS��I BOPH TrHE;LINi, , : 1 ¢ W m LLI o w AN-W' `AD ALMA%BE ENERGIZED: . rY Q d o f,IN-T OPEN POSITJON 3 = O c o0 �r. !kis _ate �;+l:1 a Z oo U Z O I- J p INVERTER OUTPUT CONNECTION; TO BE INSTALLED cv U w Z AT MAIN SERVICE PANEL PER NEC 2011 690.64 (B)(7) Z o. vve,RNiar- :._:•„", ,i,,t rm, VERTE Py1,,T°GOIFINECT1oN ; DOyNOO REI G3CA�`E ;'y;1 +4, Drawin0,No.; 7295 THIS OV RG RR NT D�EVIGE{� Drawn By: DB Rev.By: . Date: 27 Jen 2015 SHEET SIZE' TO BE LOCATED AT MAIN SERVICE PANEL: ANSI B UT110N "x17" SOAR ELE Alio-�SYstiE,M CONN�FCT,E9" TITLE SHEET: 'jrjj I LABELING PV-5 nrge Home Enphese•M215MIaolnvarter//DATA SOLAR Enphase•Mtcrofnverters INPUT DATA(DC) M216-80-2LL-522-IG/S23-IG/S24-10 ROOF /%� Recommended Input power(STC) 100.270 W DIAGNOSTICS MaxiE n p h asem M 215 Peak pom wer tracking DC voltage 48 V SOLAR AND ELECTRIC,LLC Peak power backing vel lege 27V 27V-39V + Operating mage 16V-48V License No.-•" Min/Max start voltage 22V/48 V CONTRACTOR'S SIGN' Max DC Short circuit current 15 A Max Input current 10A ,,,OREF a ey fl, d,;,j ,i s' .,...r i /\'t OUTPUT DATA(AC) .._.._.�.—__.. �2Oe VAC _-- X240 VAC ._".-...... w°=•r r�°z��, S^ 01,f..,,s , iT'',r uay" s"°,,.,:; Peak output power 225W 225W i + ,^- u•, I Rated(centinuous)output power 215 W 215 W ,0 rr. . Nominal output current 1.1A(A rims at nominal duration) 09 A(A s al nominal duration) r''-'0';'111 AO �'1`;'1'',T'; ions. Nominal voltage/range 200V/183.229V 240 V/211.264V ht,ytr? ,,",S.iT1, Nominal frequency/range 60.0/57.61 Hz 00.0/57.61 Hz r1."4r,,'i'; 1;';'-; 'r l',l`' :V p Extended frequency range' 57.62 5 HL 57.62 5 Hr �;, ;•)�`�7KSPI- i4i' itr:' Power factor .095 +095 r.^ . n '‘,,4?,..)tr v(�'t'�'�t'....,'ra..P1 er�;ym�:', 1�''h- a4' circuit i pew" h Maximum units per 20Abrandl 25(three phase) 17(single phase) ,,^V°—T':fy AAA `i.'�.. ,( Maximum output Iola cement -_--._. .._ a50 mAmns for 6 cyeses 050 mA rms for 6 cycles . .._.. UJ li 1 v�;�u-ez^:s: gy,, EFFICIENCY ._.-.._-___�.._.._. ._—.._..._,..._.,--.._..—.-.._._.-..-"._....--__._._.�.. 0 1f1 O CECwdghted efficiency,240 VAC ~.965% Z Ill n N G l,,'-i, sN I.LI Z a) t; o MOMO e:z.cz-�M`' `°4 CECweighted aMatericy,200 VAC 96.5% o ti:ri',r„),,,,: „fyg ^,., u } t,1 t, r<' Peak Inverter efficiency 9G5% w Q ,•] >, L O•,- Static MPPT efficiency(weighted,reference EN50530) 994% o '^ O Z M o0 __._ ._.__ _._ __ _ - .... - Night Ilnterowerconsum Ilan 65 mW max < W m LI CSD a The E tphase'M215 Evtrcre)m urtcr with integrated ground delivers increased energy harvest and ^MECHANICAL DATA __ __ ..T__ _-- u = ¢a s c reduces design and Installation complexity with its at-AC approach.With the advanced M215,the DC Ambient temperature range -40°C to.65°C o =0 o c Dimensions(WxHaDl 171 mm x 1731nm x38 mm(wllhout mounting bracket) i Z o = Z ,,- for is isolated and insulated from ground,so no Ground Electrode Conductor(GEC)is required a e U Weight 16 kg ISA lbs) O I--' r the materials nverter.This further simplifies installation,enhances safety,and saves on labor and Cooling Natural convection•Na fans N U FW- Z costs. Enclosure environmental rating Outdoor-NEMA 6 0 Z The Enphase M215 Integrates seamlessly with the Engage Cable,the Envoy”Communications FEATURES Q Gateway'",and Enlighten',Enphase's monitoring and analysis software. Compatibility -- Comnpatiblewith 60-cell PV "_ __ Communication Power line P Fi G D U C T I V E SIMPLE Ft[LIABLE integrated ground The DC circuit meets the requirements for ungrounded PV arrays In NEC 69035.Equipment ground Is provided In lila Engage Cable No -Maximizes energy production -No GEC needed for microinver ter •More then 1 million!lours of testing additional GEC or ground Is required.Ground fault protection(GFP)Is Drawing.No.. 7295 Integrated Info the mitxeinverter' Drawn By: DB -Minimizes Impact o1 shading, -No DC design or string calculation and millions of uritis shipped Monitoring Enlighten Mauagerand MyEnlighlen monitoring options •� Rev.By. dust,and debris required •Industry-leading warranty,up to 25 Compliance UL1741AEEE1547,FCC Part 15 Class B,CAN/CSA-C22.2 NO 0-M91, •No single print of system fallwa -Easy installation with Engage yame p Date: 27 Jan 2015 0.4.04,end 154.1.01 CableSHEET SIZE: •Frequency ranges can be extended beyond nominal II to(peed by the Wilily ANSI B i [e]eP1pha&e' Si. To learn more about Enphase Microlnverter technology. I ,1 enphas@' 11"x 17" E N E R G Y 0 VISIT Fnnila`cl.GOn1 L 11 E N E R G Y TITLE SHEET: 02014 Gktzo Bl55 r'./ghbos.,,d Si trsS'neita°t bmdclin Uhl d°amentIre mpaored try tlmhiwgelnn owner f INVERTER CUT grI ( SHEET PV-6 nrge Home SOLAR 8 g SystemEnpliase'EngogeCableSystem!/DATA ROOF EnDIAGNOSTICS Engage Cable and Accessories __ _.... ._.._..... _._. _ SOLAR AND ELECTRIC,LLC CABLE TYPES/ORDERING OPTIONS Enphase® Vo Engage Cable Voltage Connector Spacing PV Module Ddentellon Model Number ACannectors' W010hY' License No-•"• 240 VAC,4 conductors 1025 meter(401 Pork-ell ET10-240.40 40 40 lbs CONTRACTORS SIGN: 240 VAC,4 conductors 1.7 meter(67') Landscape ET17-240-40 40 45 lbs •"., 200 VAC,5 conductors 1.025 meter(401 Portmlt ET10.205.30 30 30 111.1 ,ypeo ARC "'NOR*al 200 VAC,5 conductors 1.7 meter(671 Landscape 017-20240 30 35 It's c ape a,n 1k:, 14•r�� •aduterrnarerhaparacNlhnugh Enptse mob°r.iabtnbulom-as Ighla omapraanaln W T CABLE SPECIFICATIONS •'qr ukase�oQr 1st lit, "• ....1 4 ,'.:;z;' Description Rating Boa Nei Cable temperature rating 90°C(194°F)weVdry Cable Insulator rating THWN-2 jr.-{-:, I,.. _�" UVexposure mlhlg UL 746 C,Ft _` , ;,�,, u Conduclorslse 12AWG Compliance IEC 605201P67.DAN/CSA22 2 No 21,102.3,UL 486A/9.514C,6703,end 9703 LJJ N • '71"-1---'' -:r'''N.., Cable rating TC-ER O -2---- I Cable Diameter 1.25 cm(0.49") M LA N ,.. T- - -•m Minimum bend radius 12 cm(4.75.1 -O) ENGAGE ACCESSORIES re' ^ O Z>-coO '`�� Branch TerminatorDboeeeeetTeal H W m D CO p N h One terminator needed per branch ':11.41,',C,,,,,, ,gyp Plan to use at least one per U (� The Erb aor i Cr16fe Is a continuous length of 12AWG cable with pre-Installed connectors for �(Ir`'�>ir clroml 4 Installation p = O : S Enphase Microinverters.The cable is handled like standard outdoor-rated electrical wire,allowing it �. ET-TERM-10(said In packs at 10) 4 ET-DISC-05(sold In pecks of 5) EZ o U Z O to be cut,spliced and extended as needed. ..J . J N= w O The CatgOQQe Acccaonar+ea complement the Engage Cable and give it the ability to adapt to any 0 1_ Z ---_:_ !'' Watertight Sealing Cap =-rr Cable Clip 0Z ,-,..•, Installation, r,,, ....„1,-, ,,.„, One needed to cover each unused MenynecletlloMsloncebtlug Z Q _._.__....—._. _........-__.___.._... 1•q!�� connector on the cnnnng Io the racking or to secure lou[1otl AIIET-SEAL-10(sold In packs of 10) cn 11105 ET-CUP-100 Gold Is pecks of 100) FAST FLEXIBLE SAFE •Quick Installation -Sim pts design -No high voltage DC •Large branch capacity •No addltlonal cables -Reduced bre risk Drawing.No.: 7295 • ;r`1 Engage Coupler Drawn By: DB I Used for splicing Iwo power cables Rey,By: "• Milan an array Date: 27 Jan 2015 ��•' f ET-SPLK-05(sold In packs ol5) SHEET SIZE. ANSI B [e]enphase Sp. To learn more about Enphase Microinverter technology, f enphase. 11"X 1 7" ENERGY C /1--US visit rrnph-sre.norll 1. ,)E N E R G Y TITLE SHEET: ICI Nil Cnp1¢v Entrgy M 00.13 raaroih wluaNnwb orbmnm lnoN WCWn'nl fN mapllrw1nyrlsbmppnrlhd ovnv fa,aENGAGE CABLE lif A . CUT SHEET PV-7 nrg! TSM-PA05.08 THE UN[VERSA! MODULE Home Mono Multi Solutions -" 'i `1 ' 6. .. t • - SOLAR ir'^*y� i , I I,IMT9(,19(7,Of 59071 1 •SW 1600.03 uJ los Ai ru1a a 57, SW,lin I.'A 295 lirs.ra 6065 777, 1603 7t0 ^-A�•n�m"+ ' I tI k rA,909 784,5,r1 7-8506 1717`196 tne,v , 0(178 Pak Bawer(90,7:!w.rhp( 240 245 x50 255 250 ROOF ! : t III i ° _ _e Poer001pN1014O,8ePas,1%) 31.3 M-3 0/93 01.3 0073 DIAGNOSTICS • Mai'rare Fcrnvuuge-Me!VI 299 302 203 305 307 q . I• i '''''„:,./"„ - A5anmar,l'twn,co,-nil...181 810 5,11 8 s 0&, N 47 SOLAR AND ELECTRIC.LLC Tsk ( j , i ! 1 _ Open C9lau0V:lla9eVia(Vf 373 375 316 3957 37.9 .... Ji b ' ':✓ o ,,8 _"a e,l License No.- i it 4' St'cn Grc5lt WnaM he(N 8.62 666 as0 892 900 • '1' 5 VOW*07100(9595.(3l 147 155. 152 156 15.9 CONTRACTOR'S SIGN: THE UNIVERSAL MODULE I .i' . . 8 G rorW 19,000 Wh•Cnninmoewlvm4CGAUM nAM,3ec nJ,•BIOF+p9Cla. Arn,pn•IAGnrcvn.duc4on 0143'3 m200 Nlm,eccba np,B FH 40f 01 I A .{ ll. :,::: er'%� - _ "11. 4 3 1W 740 71(13 sib 1485 y,n IS,'AR I G5 70' ,o'� F��194'm10 t 11•!'IAlt,n 110.11•l,/>:1 ���!!! A .. .4 ,. I:.Y5a3 YAnRU1 :AU,•b Yl.B1O PA"906 ¢ .� ys air CELLI Mai5xmPowe,F.A.IV1pl 174 176 181 167 196 } 1 # 60 'i I • ' .n, wr MadmAan PCwC,\451f3g:-Vo IN 263 26.e ^JR 2'x 27,4 NAq 03320 04. o . ' I S A A r.4a5rnonhaue Curled lw 01 65,1 664 6.70 511 AY6 j.OF NE�+ MULTICRYSTALLINE MODULE G '•/r�x1°'^• Open C6eVn Waage OA Vec hi, 341 X342 343 344 34,6 • Shan C1,0711Cmwr4(Al 1.:(81 708 710 720 771 7,37 24®-2603-�{/p},/� 1.---1111 . 166 110C96 .11nc60,110080.'Amb,61150900100,2:•Cwlnasaeea1mn (08480,0 POWER'OUTPUT RANGE Our most veraltile product MCCII8nICAI001A LU 1 1 • C..'t r(lh''hly v Oh(yr (03.Or(!C?-s CN-a;,-,n,',^,I'.�OCl'y l"'S 51910,7,705 MunInalUl ln,116.1,6:ha(61ruh«:' WCI i"I.' Cm'lo,lenralCn 60aef 6•I( O 75O9 % _ _ _ _ FFF Jn. MaOlue a/met/Von3 1654�972r 35mmI6J 95.3irJ5.1371rtnC51 M N O IWel le 64 410bs1 W a, MAXIMUM EFFICIENCY A•A 093, Nigh nanIarencysea,gl6Ss72rrml0.131n:7r6 50 f Z I CI Ont3 of the iiduslry'a moot Iruated modules 70166/ee! y7N16 w _ ]>. 6 4�J ^I au 115(0 0"bnl 1001' harms 808060 Calxo n1$,70r,vm Aio.1 G IY Z co O _i_ MF � + -1',a o"•:.-(1 pa,hi,1017KC. I o(Britt Y•S 71(00190.3 tun 7J:l'N,r On J 90, 11--19'671,119,1 97Q nil W 6O 0°�'�'� a C08le7 F9olo56l1056T 0860160/cane4,0ma"10036lnchet'l. !- L��/ m n r O POWER'OUTPUTGUARANTEE. - - - 0oomm 39JlndY51 ai L.6. Q .�1 To 9.m 1 C.sonocln inglnCIMC4 w ml mwrm'' 3 == o 0 Hi;;ITty rr311OLif 3 duo to 3lrirgoni quality control '83 ami 1_wiao a. z .6 z - •nl'*'An, VI° r+,n•,:'I••-, ,-„,,,,,.,,..:.,...5,,,•,'!. T Itr clad n'on'•,•ICIcQ p°" C I""' J 'A •i„h5"0,5,-In hnp q,ra•,-0111.:;701.'7 n'•,nD.ln nvp„I^nn-al d 3m /78 719.0119:05,117 010511.15 ::60.119 5.1 PmmrS .j N= O Ai,,,, ,.11,°.,,9,1'LI,•1..91.u, J Z u '1 ,.ve.1 6,6u•16' VI x,06119. ,- horn/nal Opevannts Cell J5°C(_Tc! opewllrnollenpemlare •13-,894: 0 (,� .x.1:7,.1,„0 eV 7.,' ,.,n,.15 I"i_." _` .-, lemq,yµIr•n 61OCt1 Mas man2(,16119 I003VDCQKI/ Z , I II,,WI,15,+:1111,<..11 - , TtmpOrokro Width?of Fr.. •0.4357,C 065(036 480VDC(55 3 an `,pm- 2y'm 50.- LimZ 0- 0,,•h,•., ,i,1,0101 I1,'••O.n' ' - -- - -` - 609,470(15 TorrpolOW,o C85%15MOIVoe 0320/°C Max Y_ila F,06 Rallrg 15A -7,5, 1,Il 0,/,0,...!. .11.11,11'•15''9,' T<+npolal$ro CaelR<Ien1 oil,. 0.047951°C n.'_,..,., '' n,.,a.• Ccolifed to wdhotemd chatiena,ny envnonmontal .r,ipl arra 0,90 v. J 0.'r,y;., Conditions - , Iwo .0,19,a .5,008. 7991 t• 119.,,9 IUaa 11JvQ fhQ .,6117.6777 170(01_I 1, . 01,0„1:'1 •%':15 cj.,Ina rsI I_ 114721.',..6.1511.11 ir.11 IoyearP,aavclaaemonsnIpVeananly Drawing.No.: 7295 ..i...•...,,11 ,,. . ..i1. i� .n -4.0,0,11,.�. :-uI 25 vca,11/100,FJ.a.:070„anw Drawn By: DB IRSI,; .I", *47'_I,,s 1790,a0inI rma,c,wmw0Ma1ae1m71 •• S. Rev.By. .,,.I,1v Il.,nn, it,1, Dale: u.,•1,,In 0,.I 0,�•ui ,1•:0.It i'WOK 611,19:haul 27 Jan 2015 :hau"'0,0010 17•'1.1'9.' LINEAR PERFORMANCE WARRANTY SHEET � 71^.9 Fh�MShci'-C•,i'4':'IhAOJu ; SIZE: la laa,Feadut!VJcrmnfy 25 Ysnr 9919,191 P,rl nr 06191901997 - «• a nlaevm por 0^r x,.,11(•19 S 17nn.d.nlun9..J - -- -- ---- -' - - - 3 ANSI B .,,, I- _ Ina- 0 !ce I 11®m /Vi.i. Maniespe140.<7.9,0190081206005 - - - - -- 611«"+,-,1,01'1111.0 , i __l ,rmr 1111 x 17" 5,:: --•'-- n'A,"n 0(19,,.5,, '``"':'1+r�.'� ,'"u1 f 14p'n•lrnrrY CA.9 5,1166,666- •,nS tAIlS 1,11158311018 111r0116u5nla1 .411:1 TITLE SHEET: 117_usdor 1 6CX A, h.'•,, r� •., x"+y,• ;���� 510}]19„0 so,a.(49 $rnnanr.,mo'we Spec/500,r r804tA ,196 el 11,10,w[beps ■, 33 ��� �tl a.m,,6„na19.d MODULE ..mmlh+'°,gy Tn8.410911019 .•5'. `•Ic 15 ". cs S,nm,Fano/10-'i 0' r 13 I,„ti . IF V I CUT SHEET 'I PV-8 nrgL �UNIRAC UnlrncCode-Compliant SolarMount SOLARMOUNT Technical Datasheets :PUNS t Home e SOLAR Part III.Installing SolarMount SOI-ARMOUNT Beams ROOF Part No.310132C.310132C-13,310169C,310166C•0,3101630 The Unirac Code-Compliant Installation Instructions support applications for building permits for 3104080,31fl2110C43,310240C,31024110-F1,3102400, DIAGNOSTICS photovoltaic arrays using Unirac PV module mounting systems. 410144N1 4 I 616013,at 0204M,410240M SOLAR AND ELECTRIC,LLC This manual,SolarMount Planning and Assembly,governs installations using the SolarMount and License No.- CT SolarMount HD(Heavy Duty)systems. Properties Unite SOLARMOUNT SOLARMOUNT HD Beam Height In 2.5 3.0 CONTRACTORS SIGN: [3.1.]SolarMount rail components Approximate Weight(per linear ft) NI 5.811 1.271 eti¢geF fros� 1 :t1+ Total Cross Sectional Area In' 0.678 1,069 m°off'w P�sr ran rr-"t'`a t::;yt •= 1/41,',4- . , a..t„ 1„,,, P•• Section Modulus(X-Axis) In, 0,353 0.898 * 1-Zsl r -',-•' `r"�a• '_;r er.• © ril Q section Modulus(Y•Axis) Ins 0.113 0 zz1 'Trto,f, coarors 4c, ,"f :.urs n,;Cpm'c t•ttA,,©t„� ,tt` 1U1 Wi'O _th'i's=”- 11.111 tom;,- Moment of Inertia(X.Axis) Ins 0.484 1.860 t,,s,' •'1,tipg��R; 4 �-'.�.,» ,�, St ,�"ast's (pi�""� Moment oflnettla(WAxis) In' 0.044 5207 w- t)' a •--.. r Radius of Gyration(XdWs) In 0.289 1.170 ' - '�r^' -•^..'� Radius of Gyration(Y-Axis) in 0.264 0.502 `O^-, �+,,y Figure4•SarmMountstandard mil components. W N •Balls are exfruck('using mese aluminum alltyx 6W57S 6105-TS 6001 To 0 in N Z M m N 0 Reil-Supports PV modules.Use two per tow of lock washer for attaching L-foot.Flashings:Use one per LU Z a) C O modules.Aluminumexrrusion,anodized, standoff.Unimc offers appropriate fleshings for both °^`i,;,,.^^�ca',"'r+'��".-'^'y, „�-*^-^^7"'"^'^'S'o,'= ,y-q,,";""` "`•'3"+'""Y`-^"•'e*f,'^';9 ti� Q s C L .�y,,,y,.a.,,t.=•i:: rF.;�tF'c:"r. • r.eb' ,. h•.,-y it 1.. ate- Note:standT eretyp ,-.. ...� .... t .. ,«_.c,•..::; .... ..a`,..,. _ .F'_i _ ...,.,�t .b.,.. ..,..�.`•�:d us O Note:There Is also a[longe type standoff that does not ¢ D_ Z M p ©Rad splice-Joins and aligns rail sections into single ❑ length of rail.It tan form either a rigid or tltennol require no L•foot. oa ry i m W expansion Join 8 inches long,predrilled.Aluminum O Aluminum two•piece standoff(optional)(4"and 7") - < •I�_L/I co D =2- extrusion,anodized, Use one per L foot.Two-plece:Aluminum eatnisfon• w LL Q C! O Includes 3/8"x 3/4"serrated gunge bolt with EPDM SLOT FORT-BOLT OR 1.728 =O ' o AOT FOR T-BQT atO p hasher for attaching toot,and two 5/16"leg bolts, '4 z 0 2 ©Self-0rfWng screw-(No.lOx%i)-Use 4per rigid _ 'HIX HEAD SCREW �•,Hnw y 0 V Z splleeortper expansion Joint.Galvanized steel. Lag screw for L.fuot(5/16")-Attaches standoffto CCC 0 I— -J . o rafter. 2X SLOT FOR t'} SLOTT; 7 N = W C 0 L•foot-Use to secure mils either through roofing BOTTOM CUP rl 2.500 BOTTCMG.IP O 0 i— z material to building structure or standoffs.Refer to C' Tbp Mounting Clumps Z loading tables kr spacing.Note:Please contact Unfree i �� T7 3000 0- for iseendspedflcatlonofdoubleGfoo( 0 Top Mounting Grounding Clips and Lugs 1.316 ri, 0 L-Foot bolt(3/8"x 44")-Use one per 1:foot to secure SLOT FOR rail toL•foot.Stainless steel. ?4° `' AOT FOR �L�1•J 1 Installer supplied materials: HEX BOLT SLOT • Lag screw for L-foot-Attaclses L-foot or standoff to I FEY,BOLT 0 Flange nut(3/8')-Use one per L foot to secure mil to g 387-+1 I Drawing.No.: 7295 L•foot.Stainless steep rafter.Determine the length end diameter based on pug- Il al Drawn By: out values.If lag screw head Is exposed to elements,use 750 1..^01 DB stainless steel.Under[lashings,zinc plated lmrdwsre b 1875 Rev.By: "• 0 Flattop standoff(optional)(3/8")-Use standoffs to adequate. v Date: 27 Jan 2015 increase the height of dieiearray above the surface of the roof or to allow for the use of fleshings Use one per .x • ►X SHEET SIZE' • Waterproof rooangsealant-Use asealant appropriate L•foot.One piece:Service Condition 4(very severe) to younoofhtg materlai.Consult with the company SOLARMOUNT Beam SOLARMOUNT HD Beam zinc plated•wetded steel Includes 3/8"x14"bolt with currently providing warranty of roofing. ANSI B 11ii x 17" on Dlmensbns specified In inches unless noted 14 TITLE SHEET: rat SOLARMOUNT allillitlE1111111.1 CUT SHEET PV-9 i,1;11.3,;"ti..y '.l1•fA 6`,% .9SIf;.,t;,p�,;;J,i,Gretrlrbh•11 Gh1-14udm.l 1o0 h Dn1alldll00 ln510141iunswkll Cum Iesslml Bmcke% a •¢ ''Gu cnF.nbr+GF1•PioduU GukW 10314IsIIu0 hist ludlunsw1111Cmn res9nn Bracket Add for Pldler fI. YL l '� 4 ; .� (e agf, � f _I `yyiL' r1K fY' )' I -"_ y-'°,a -`�'?.. 3tm • {`rf`. {'pa°,�s3 !i 1 -'1-" AY,,sik4+� N ` - SOLAR a� � �, „e n t)� �x� '” ROOF '4y iYiu +e °f,; >r< t i',F a 2e41.0X^ I c Mr. 1 , v „stir ;' ';ssr�-411 1,,1..,,, j ver —d2i'` d'y ; '•': e .. II rl1 ;r;1 Y.' �t "`°27i,� f, � :_ 3 C ,•i: i;.4,i,.,'' '1'.',.; x'^i tt'4 _ T•" : Is `�/' r DIAGNOSTICS ,,t7,,:L,nq :' ,'2 `','4, ,y� ;4y. �,�li.,-r 1,_ 's�, I Vt `l,,_v.i`�cT, v .s' SOLAR AND ELECTRIC,LLC [J '`",le 4jy s^• = :,:,,. " 4.14 „ : ,.;, License o. ;f GtYI I i`� 1N11„4 3 N _ea i.,..,µ, ,A 1 2 3 4 F,.7,.,,,{' 1 2 0 4 ^ rtt 1 ,� CONTRACTOR'S SIGN* I'i 'w `ir' «fir'« I Locate the mitonand chop hpn)anlaland v,liC3I lnesWmelk lire i,i'•i,;} 'y -y..16,s 1 locate the fallen and snap lwlkontel and verlIcal lines tomaik The •k�"- ' ' • r Instalkllen position lot Greeniesten no bins -�,q �y = '",n (y' Inslnllnlbn pa9lbn for eachGreenFene laahi 9 iv5r3 L ,6•.,~.,y IyMr"�,., .�;�, ' hut'' 'I '°„ - 2Dn11eilot hole the leg bolt 3ookkllw11h 1oeloon. PEDARO 11.,'14 i"`i"tau' r- 2.Orllletho Se le(IWdlametallaI node,Dolt mallow i gte,L• 1f;I Yl:,r..,. •:,.¢*''1,; - F "..,,,,..,,.;,•,,,..0.,),..„.. r RtIC h h 1`.li'.:*q,r„•-141 /.�” `',4 . 'b�4 2.Insert the flashing so the top part h under the mallow of shingle, r"t�;k" YInsert the the lop penis under the nelrowolshngles tv, on., ^ `, andpusledthr enough up slope to prevent weln1MJka1bn 11nuugh .'':i'3•,C,r�E"-^^ / T t +L' t•4' and pushed rap enough uodope to emooni water lnlilhelkni through ';It'. SSer'; rr �,$fd�,`, vrnlolpinInshingles. frit ;4`5..'' A i�igt 1'• day,+. 4 t �v .em:altamtm01142,e. + . 'I x} j 4.lIM up Pilot hole wIth GemFesten hale (7 .usyO' xYf T' 4 1';e`4'F��"i' � 4 llneuPPlbi hole wIth GleenF+sten hole * � �, 4.Ir,(- ;:ey'vr 1 1144'1. 4�IIyy�}, Y t , • la; -I •Yyy,_+c Gj : '.fy/iL°1y,1;,r T1 'lk'' } :z �) S Insert the lag bolt through ll,oCPDM washer,the top compronien •t,"'e;,J1,n s 6" Z±• '• • "`R••4 5 !meltlheleg bolt the CPDM washer,the lhbd-pmIYb,00Mt. d} Qi" ,y 'r' component IL•Brecket Pktu,edl and the saskeled Wahl,the b0111 ;, J k`ri • tr Ilmcomproesbn bracket(Cr.S¢SIoliedplclured/en411,00sheted 9'' PS6Pag{o 14;1"? rrrart�,{d , andtnlo lMmfter �aP • ' "+r!'., holo In the flashing and Into the faller eOF 11E` ,Z- y rl. Z 1f p. 'r t:,., - ,° 6 TPig0e Thenngelsbetween 100.140 toieaelnq.ppondsdepending ;•,,,�•,�yqn q.,, 1`Y., r y •, ^f' 6 Tmqua it cpange1,bemeel,I0P1401V,gieIncl poundsdePentlleg ' E.i „� on the typeof wood adlimopfyea)The vis Iindkatorfor proper -, `i,5 F r• �y”' on the ypeol wood and IMeofyear The visuallndlWlor for proper qp�1 Ioryuelfwhcn the EPDM on the undonldeollhebon000 rashes ,5 q�;�-�� Iorquels when the EPDl on the undenkhe of 0101=4dedwashlI '(V ,.,€S210. begins to inch out the Md.as the w,lfheieemplmos lT usingan -k'.7`Yi,mu"r,.ii bvglns to pull out the rides at thewuher comm.*,ll 0510g 411 ?;�1 i.,r,� S 6 Mpaelwrench mlnsbil lhelaslenwt DeGMul not looloe le,grrallw ,.° 6 6 Impar wrench comstalllhebshlnenbo Grote'not to overtorquade •,`:,1..':w�,^(7 10,10001 You may nerd to stop and use a ratchet to Wish Do m3I1IL p�'',1 rj- -I Iaala,00 You may need to stop and use raInhol �i,{.'c,v9'y \`r''{+'p��"- to finish dlalns01 VV.''1_ tjt Conseitanengineer orgo towwwe(ohlamoblromlo,engineering data ''',A`:-: _r w '''�4,,,,-. Consulter enginceroogo towwwae lo,lensebrmm for englncenn2 dale W -�•')4:',?!'. ;�,.an •E.uresWnr rem,ldsan CPDM Muth. ell,,i. I i---:;' or,'C y, �,_< `Ecotone,recommends an FPD;mss6c N (,•r .M1Y:,.,v, , .,is umnirim lee r ""-'-" -__.,._.__._..._.__.,_.__. ._.___.__.�_.-_..,...-,.,. ___ter_. l_ '� }: r,n,,,.ri t,nnnn .�'-__._,_.._____ -___ _- ___.___, __ ,_,_ as O f,i^;di -inI0ntnnm,loIII4,ams0u..,canmrroMn,a,.mmuiinn1t0, ,lFl It nm .i I+' V,9'-` bio,;wv.vmn:,.,..u.m•rVr,4w.nm„n.,,i1;7,-er•,+io-lu.w,m¢nia„er :,7r"ieiu7,er 7 M LD O Ili est cr ",',:Y;e1i11`>it^, c1.7k,.�;',,,, , N W z ,— l; a rt •airy v,,r.r4i ct;�%Graeif,1 1,Gr Pmducl 1,mdu Inst4llallon inheritors ;::1��'':�ik''1.',I GFnwIF Moll CF1-1'Iucha1 Gulled Exploded Product Vlow,hill of Malermis Q.z gs•) 0 •Die far venl:alaelmtmenl when lend n7 etc Nu ons lnu g 'R 'I cm rvp :__ s Fa- W m i m _o +.I - .•-I+'"^�. Materials Needed for Assembly ' Q d `•� O G ,eO .. O I.SI1de Warhlrg.Munder shllplos until leerily edge Z.Pemovaflashing and N•natch at mads where wlbhafb 1. Item Na Description of Malal+VPl1 W+nllly _ O 1,1;')'j}[ n eyagel palls.MevrvleremainingOtrantoto adjust ertgegtd leading dourd2Io,the distanceJolteddIn Stepl "rely', '' 'tar i jYl,e,y1-.. q 0 V Z r „•. “onpe wasLemaU,fvwP< Notch depth nnl lop-creed 2•letplh hY ln•whfth t�,tv 4'l „,..„,--1,..,,,,,,• �j�.^. 4 +„'Sh I Cd 1FIasIJnO 1 00 J (yJ -,`,.;1;,:t,', tS .:xi `+�J 2 2 1.1027.11,46el•04144oplbm ril11110 1 _ N D W O fi4 a y a-./ nc�emem of v'notch ,�+;i IQ P ser. Z jt+” 1 1 ( ) �` "Y` S 5/16•EPDMIlondd 204 lgBSS washu 1 0 .L i"-.a`d(I _t ';? J'0 yv _) 'I :,hytf I ,10w,-3 4 .,.� 9 lag Belt 5116• I O Z a r,' r ) , �.y , .f 1 , f'".1`'<i l'lEOAv"i, ,` 04 '.':v: - - �J .,1i)j.3''3„Y ✓ .F� �Ai'. w t"i 2 �y`yF> i .m µ� i.); . t S 1/r '.'0-4'',,,r,�j F i :;A r 'CC' �ay^,v ,i ,:f-,F}r - '-k,�. .r.,,`x<r,;"' :'l 'rE .-.. 11c9ulredTools ;,,�''14 n`cv)�t ,,,)�I, ,1 k n w�,R', s 9 . Drawing.No.: 7295 ,(iJ1,:{,,'i,, '4,:,..v.,�h`,1,, 0 .ter,,no v (Q',•...,t,.,0yDrawn By: DB ```5i`',:441'%,1 ',”-i ',1t ...� ... - 1� e. ` x* �, i`.,;a._,r,.,".4 1. ;�'ti Rev.By: �':,g kI/ 3 NlnflalllmhngVal CIMhdarea upalope 4.Irosmonnmrnedleadingedge undemeanlnail heath esshown 1"'41;:-:"'.73.11t.-0, - ,13' - 'ti; () 1.",7.,^, f,t"i%4IE'' lhpituxl'b sr N+I shan+athfhmd'a r,t," 10. ' '' r+ I Date: 27 Jen 2015 p, ,;.;e-� 6.• 4 e / I,g�e . • -, i �` SHEET SIZE "1"�i"y 2 k� a `- qY 1 1, RRR" ;r. N';:..E.:-.',...'..-0 h "r 2 Ka . y _ �; `" ANSI B } y 14.'14 A5 r 1 - fpr{may ;sis z}3 �-y t'3'3,',3' nn hf.�: e � '', ;. 'e,IP, Y 11 x17 '',:A1-• ,.r...1•1,0 ' 'ski„ ? ` 11$ f:�l' .,Y'c• TITLE SHEET: =ii'Y .';'r- 'h•:>j.1! 1 ATTACHMENT ;;),..,� ; '' 'Ptd A . PV—CUT SHEET ^h `,���lolMl[en n•.asttn mpg pfn.wrb+hw�r, hroiW+aar,�r uxlp 4rl,mm+.nryrgia rf,�>I+il��r 11�_I)Ivt�—'yam—��r_ y— )r `",''j'.n t0.:17ilammin7,pM iry,rr,e mon•+eC;;;;7,l;,—;;;7.1.1;;;;A=.7:1774(175.7:1,•tt,Lr5 Ar;,1-1.1-3Z.7In r7•i� � ��f` 11 ,;`'_,,.'7Y, . . - PV-10 * nna. Home 1 . ... DIAGRAM-TYPICAL CONFIGURATION era6...U= Product Datasheet SOLAR ENERGY 113221•1111,11111 VaS r-INE ' .4-- ROOF •.• 4 ,01/f1Y/il CAI, III'glib. DIAGNOSTICS INTERNET ,,IIT,A'AF,,.,,ITISW4I0E11,0X1, SOLAR AND ELECTRIC,LLC LGate 120 ‘„,,ry,-;,,,,7,0,,,4„,..,...fa,K ,..,V,,M.$ Limnos amain TRUSS!MITUTISI - e.---", '-"1.r,VI'' ' ''' 'ffi"'i 11 Iti613111"Slcialal ...-",. la-i-- RESIDENTIAL SOLAR MONITORING SOLUTION ,••i•0 4:,, . -,.• MIMI P,M1' CONTRACTOR'S SIGN: 41'4,„.'t 4_,,-,4" MIR 9E11 Pe!, • ) :II i li ,24VIIMI.123.1 .,-,-^, 3. ----.' The LGate 120 is a single-phase electronic watt-hour?peter /'Air'w..iiiii-...xi.ii...iit ,!, mom maw '''''' ' '''''' ;riii,Iiii .2 ,tiii.i for rernote monitoring of solar bbotovoltaic systems..it 0.,;., I ELECTRICAL :r„.0:44.4",.., SUMMON antuum SERVICE features a smart.communications module to automatically "AA I frii,4,...lritl.;i 8`;Y. . '41111a Ogn 'OVERTONE/ LGATE 120 transmit meter data over cellular or Ethernet networks A,01;iiii- __-, ---`-rik r• i„ PI/ARRAY * Ilii-t•Mil * IC-21:41,t7,714 ,I' ,e."., •L'a-, IT•' allowing system oValers and operators to easily manage :144,..',.S'iMM.„ ,...i;11..7.- nnaa 0 40' distributed solar assets. ?.,,,ii- ..„."ti--,.:.',7 ,,,:"-- ,; Z,11.4,:.,2,,,,,,I.k*er,-,•5131,,.,--f& _ 0,ti Eq4 DIMENSIONS , . ,in,PEI:Ii13: LOCUS 1..14WEV iirrcaRAIC METER MoDELE ceninnn HOME TlineLG,I,I 120 COIRIono<.1.e/./11,0'1.10,1th'.10111,1-si,,i,,1,1LL0t,Iltolc,*US,,,,LLIcere,,,,1.:,.1,1111/31/l/.../1 tor,,,:,/,/,,, ., 0,.0,"0%1 ta cal .., :,, a— Tfve cornonnent:nit)nil cOf wm-rmen 10 C.nitaeln, run Smith tite tint IIII maw...ill 10.7.1(I.:11 la,,mta,01109 M /,11, ,11:a://10 FL'm, CS ISI in repreileST Of pare,0,If''el"-lyne I Ii L'i:,,,,K.iill 17,n e.a,••1,00:5Cirviiilete.:iilLe•cite.--ir.•-•,..4 m.o.)inst,11 ,,. . I, Z AL .10 0 2 a g? c9 . . . -.1111111 ,.. =. .-,k,,- I ` • ly tl.,:n.: d 10 :a%Ian:1.)r001 1,a,..e POI I it? lift II 1111...II.lIf11111.1(11,11 ft I:MK ie,i14.nini IL,Om It.ip,i'lit,IN Salamis ggi,, . &III,;-,,, Iin.-111110111i9 datit,1 III WM II D'Iin/1‘11.S in-.Mt Ci•Vit,In.nil RI ERAS/Slit,.)I an.,,sPI RI Al lajr/: /' .‘'.:..',/'/1, 3 IP'ffigti' r,-F4`45-;°-'417.;- - . - I ,:.:1 ..__ ::,_. t-- I Z r' o ^ c) III CD DATA COLLECTION 4 "' -* 41,4-„,:,,,, ,--/to,,,--, 0 ‘14 < W , Acv,,,,,,t:ct a ii,-.olk,,zte.,.:lie the meter and r,,,,,,,:etr to!he,Of IIIIRIPIrn1119.: F117511.00 ALL11110,151 sys1,n, . , . 1 , 0 L12'O 1...• Perk...tin-Mr,04111,.11.ipQ ed1)l.Vt.It elli•A hi Ilium i,,,e,ev,t nqii oi WI L'I'Itk a:it I.11111J1J't•i•ft 0.'1.1k:re We f:s.iv..., u I 0 CY C'mc' 7,0,21,41,e tilifIvt I k'llnI. vii n1/II.I',',ER,Oa nE OW.40/01.10C Ornor i,,i,e1 iliein ouliniintaa1,,,upirino,1 I.,',Mort);At 9,,i.:t . Z Z a. 0 ,- coniiglircoie iroi.?•iraia SPECIFICATIONS a I— j •: Ilr=XIIIMMIIIINIIIMM CNI D lj - OCTA64°M rr 0 1_, Z A1.100 tome L1100,nu n:4 J.// AM/I/,9/'inn 31,, 0 2 NETWORK CONNECTIVITY .,,,,,,,,,,,,,,.,.1/I/1./0 01/.11,0A 0,,t-,, goitql.14./(/. 11.1 IOW Z n. < II,n i„nanniiiiii.M nail,M./Vehr.111,10.I fun IC ne..121: v)npr,In irtifienni1i I nE3V rniini,1,i)1'Inviiiiii n'-viiiiiiir in l'i iirri WI Mt**, IP,Ni•Pt, 01,0: St,toc`a..SIL cman-es Si cliUlle 0,10, MO t/I///.11 5,-1,1 Set /1 nm....ark..C.rinuction L'i•ri tile•iiiii I-iii.tailea wal',Perna!it'It•ill.1-nonvinatev I c9:•,IrEriWIIININ data w,thciii .nly conliciiii liter,I•••,t,.,It T,inn tetI1,11HI,,,,Ill,I.11,,/Ow,,,/,onlgAtt,,,,,.,...ni,„0,,,,,,n,:ally..,...,,,,ill,1,,,,f,1,,,, ,,!lip EMIIIIIMIMMI ==.1111111.11111111..1111.11.11111M e./r,/t.-y,and wino)cit,ii,liar if•i Ili,/Dr I I 1.•;RR Nett 1‘.,VT.II,AL 1.1,11110 In1.15;r....,w.i A eel Mei P20.1,00,0 ISO kr,'ell Drawing.No,: 7295 'A.. pRini Drawn By: DB FEAT ORES vitt ri iiiiii I,I'lline.. IEC=ZETMIMMMMNIIIIIIIIIIIIIIIM Rev.By: • .ft i'L,20 an iii ii,rr,,c • I.,,.6,,/1,,,I,//IN/IOil:Or I 411 fa inn liOnw 4i,.,...1 1.41/111/t/i/1.,ti1/111..V•111}. 1.1•510.1. Dote: 27 Jan 2015 ._ • rtic.itii..,riti 2.111.,4.input, • 1)p,sin',r quit 2 I nt,rihri,wt(,11101 01,, I-In). to WI, j,„t,,,,,, tO,IA AUT., SHEET SIZE: •i.2.5f4 ceilular cr l'In,i'w..fonnEdiOnly • rinit.1,,int red?an IIVE311Wri II•tuta r NI 11/1I 1,111.1411/ 0411 /‘//' I/41.W.... r.W..51.'t., ANSI B • 0,,,,,ow..,,,,,,,,,,,,,,.,.,,,,. • r„.,,;„„•,,,,,,,,,,,,01,..,,I.,,,,,,,i 1.1xtr.wl, 5 ro.111,1w111,1”4,1f 11"x 17" TITLE SHEET: ,it,4 A PRODUCTION kV 1 METER CUT SHEET PV-11