Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
37633-Z
rr N.$ FF �'�Cp6. Town of Southold 10/2/2015 +'°' P.O.Box 1179 c 53095 Main Rd ;��jq� $A© Southold,New York 11971 # id r* CERTIFICATE OF OCCUPANCY No: 37810 Date: 10/2/2015 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 2265 LONG CREEK DRIVE SOUTHOLD SCTM#: 473889 Sec/Block/Lot: 52.-8-4 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 10/31/2012 pursuant to which Building Permit No. 37633 dated 11/14/2012 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: ROOF MOUNTED SOLAR PANELS TO AN EXISTING ONE FAMILY DWELLING AS APPLIED FOR The certificate is issued to BRUCE&SUSAN ANDERSON of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 37633 12-04-2012 PLUMBERS CERTIFICATION DATED Authorized Signature I011, FTh TOWN OF SOUTHOLD r' gvrFo t-i I I am, BUILDING DEPARTMENT OCT -FICE LU720151uI �1 Ea°o' 13LD1 DcPI "oma-,rj''� :M. (' .I' BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 37633 Date: 11/14/2012 Permission is hereby granted to: RUCE & SUSAN ANDERSON 2265 LONG CREEK DRIVE SOUTHOLD, NY 11971 To: construct an electric solar panel system on an existing single family dwelling as applied for At premises located at: 2265 LONG CREEK DRIVE SOUTHOLD SCTM # 473889 Sec/Block/Lot# 52.-8-4 Pursuant to application dated 10/31/2012 and approved by the Building Inspector. To expire on 5/16/2014. Fees: SOLAR PANELS $50.00 CO -ALTERATION TO DWELLING $50.00 Total: $100.00 Building Inspector - Form No.6 V1)11) TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings,property lines,streets,and unusual natural or topographic features_ 2. Final Approval from Health Dept.of water supply and sewerage-disposal(S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. " 4. "Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead. . 5. Commercial building,industrial building, multiple residences and similar buildings and installations,a certificate of Code Compliance-from architect or engineer responsible for the building. .6. Submit Planning Board Approval of completed site plan requirements. • B. For existing buildings(prior to April 9, 1957) non-conforming uses,or buildings and"pre-existing" land uses: 1. Accurate survey of property showing all property lines,streets,building and unusual natural or topographic . features. • 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied, the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00,Alterations to dwelling$50.00, Swimming pool $50.00, Accessory building-$50.00, Additions to accessory building$50.00,Businesses $50.00. 2_ Certificate of Occupancy on Pre-existing Building- $100.00 3_ Copy of Certificate of.Occupancy-$_25 • 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy -Residential $15.00,Commercial $15.00 bate. total I v New Construction: Old or Pre-existing Building: (check one) - . Location of Property: 0�ct,5 h0 Coe0"6. l /- ✓e 5j(.11kriG !� House No. • Street Hamlet • - Owner or Owners of Property: 1.2..0 /1-du ism S . • Suffolk County Tax Map No 1000, Section _`'" oZ Block Lot 1-7 Subdivision - Filed Map.' Lot: Permit No., Y1(& 3 Date of Permit. //'f q—/Z Applicant: g 77P �Nx.e g y -5y57- 5 Health Dept.Approval: Underwriters Approval: . • Planning Board Approval: Request for: Temporary Certificate Final Certificate: Y (check one) Fee Submitted: $ 5 Opricot.e. Applicant Signature I,,,, ' • Town Hall Annex t Telephone(631)765-1802 54375 Main Road ` 4111 '1111Fax(631)765-9502 P.O.Box 1179 c i G e $ roper.richertla'�.town.southold.ny.us Southold,NY 11971-0959 . �` 1 I' lyCOMfd,%... BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION Issued To: Bruce Anderson Address: 2265 Long Creek Dr City: Southold St: NY Zip: 11971 Building Permit#: 37633 Section: 52 Block: 8 Lot: 4 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: Eastern Energy Systems License No: 47657-me SITE DETAILS Office Use Only Residential X Indoor Basement Service Only Commerical Outdoor X 1st Floor Pool New Renovation 2nd Floor Hot Tub •Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures HID Fixtures Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel NC Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel NC Blower Range Recpt Fluorescent Fixture Pumps Transformer Appliances Dryer Recpt Emergency Fixtures Time Clocks Disconnect Switches Twist Lock Exit Fixtures TVSS Other Equipment: PHOTOVOLTAIC SYSTEM, 6615 watts, 27 Conergy 245 watt panels 3-Sunny Boy 2000 inverters Notes: Inspector Signature: � � % Date: Dec 4 2012 81-Cert Electrical Compliance Form.xls I i LUIGI CLAUDIO SCIANDRA, RE. 5 Wesleyan Court • Smithtown, NY 11787-3011 • (631)543-2953 fax(631)543-1526 Cell.631-747-7495 E-mail: Ics4dnaol.com Wednesday, September 30, 2015 Town of Southold 53095 Route 25 P.O. Box 1179 Southold, New York 11971 _ Re: Certification Letter-Twenty Seven (27) 245 W P. V. Roof Top Solar Panel Array, 6.615 kW Total Output, for Anderson Residence—2265 Lona Creek Drive Southold, New York 11971 I have reviewed the solar energy system installation in the subject topic on 09/25/2015. The units have been installed in accordance with the manufacturer's installation instructions and the construction drawings approved by the Building Department of the Town of Riverhead. The solar panel installation is in compliance with the requirements of the 2010 Residential Code of New York State, ASCE-05 and N. F. P. A. Standard 70 "The National Electrical Code." Markings in accordance with Section 690.53 of the National Electrical Code are provided. To my best belief and knowledge, the work in this document is accurate, conforms with the governing codes and standards applicable at the time of submission, conforms with reasonable standards of practice with the view to the safeguarding of life, health, property and public welfare. Sincerely, Luigi Claudio Sciandra, Professional Engineer � P�� o1 N OA. 5 J\G j SCIA% fr 11I 2% 60935'1 e& A • FIELD INSPECTION REPORT DATE COMMENTS • FOUNDATION(1ST) • • • FOUNDATION(2ND) tml • • 1 2 • P • • ROUGH FRAMING& PLUMBING • . • � CG H INSULATION PER.N.Y. • STATE ENERGY CODE • • • • • • FINAL • • ADDITIONAL COMMENTS • rsJ a a L 2'(`'efr? .64/w_ d)K m • • r, TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL j Board of Health SOUTHOLD,NY 11971 4 sets of Building Plans V TEL: (631) 765-1802 Planning Board approval FAX: (631) 765-9502 Survey V SoutholdTown.NorthFork.net PERMIT NO. 37.0 Check Septic Form N.Y.S.D.E.C. Trustees Flood Permit Examined d 1�,20 (-2' Flood Assessment Form ( Contact: Approved 0420 0 ! 7" mail to: y ((,a Disapproved a/c Caite(n Enmi gri-e' 'J . Phone: 0.31-176/4604 Expiration c_.„6„ Building Inspector APPLICATION FOR BUILDING PERMIT Date /®-i7 - , 20 /2 INSTRUCTIONS a.This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans, accurate plot plan to scale.Fee according to schedule. b.Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas,and waterways. c.The work covered by this application may not be commenced before issuance of Building Permit. • d. Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f.Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize, in writing,the extension of the permit for an addition six months.Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York,and other applicable Laws, Ordinances or Regulations,for the construction of buildings,additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws,ordinances,building code,housing code,and regulations,and to admit authorized inspectors on premises and in building for necessary inspections. Eager() 69e-riy (Signature of appli ant or name,if a corporation) 7t76 9 &4&. i;q . (Mailing address of appli ant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician,plumber or builder n 'e Name of owner of premises Saw Ai e, n ��� (As on the tax roll or latest deed) If a.;. ic,nt is orpo tion, ure/7`�'' ly authorized officer (Name and title of corporate officer) - Builders License No. Jamie FVI,2net 'WNW Plumbers License No. (4 f/k Electricians License No. C04- Aja t/ /6 Other Trade's License No. N/A 1. Location of land on which proposed work will be done: 65 l�nq,C(x,e-K °ri✓e av Jd) pry i 19� House Number Street Hamlet County Tax Map No. 1000 Section .5-A Block Lot it . Subdivision Filed Map No. 50.37 Lot 2. State existing use and occupancy of preAnises and intended use and occupancy of proposed construction: a. Existing use and occupancyldem_e b. Intended use and occupancy PrsOene o,,i ' t�* added . .Iw1' PI/ 4(ay 3. Nature of work(check which applicable):New Building/ Addition V Alteration Repair Removal Demolition Other Work (Description) 4. Estimated Cost ,J'V.W Fee (To be paid on filing this application) 5. If dwelling,number of dwelling units I Number of dwelling units on each floor ,N/A If garage, number of cars _ ear 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. IJ/,4 • 7. Dimensions of existing structures, if any: Front Rear Depth Height Number of Stories Dimensions of same structure with alterations or additions: Front Rear Depth Height Number of Stories 8. Dimensions of entire new construction: Front Rear Depth Height Number of Stories 9. Size of lot: Front Rear Depth 10. Date of Purchase Name of Former Owner 11. Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law, ordinance or regulation? YES NO 13. Will lot be re-graded? YES NO V Will excess fill be removed from premises? YES NO 14.Names of Owner of premises .TCC' gA01) Address 21,945 4ryi i)( Phone No. 766- '7/ Name of Architect Address 'd" l 'MI Phone No Name of Contractor kettc4 1/IP fy(M f)JS A Address 14-76c Svod Ave Phone No. 6V-779466 rnarhh CIC-,Nt/ u75a 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO * IF YES, SOUTHOLD TOWN TRUSTEES & D.E.C. PERMITS MAY BE REQUIRED. 126-5- 44 g ftI4 b. Is this property within 300 feet of a tidal wetland? * YES NO e/ * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey,to scale,with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. 18.Are there any covenants and restrictions with respect to this property? * YES NO * IF YES, PROVIDE A COPY. STATE OF NEW YORK) ^ SS: COUNTY OF .( j . 1 19 w2j1$ being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)He is the AC4Se (Contractor,Agent,Corporate Officer,etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief;and that the work will be performed in the manner set forth in the application filed therewith. Sworn to before me thi • a3 day of( C 20 , a 4044641- I Notary Public Si% ature of Applicant BARBARA H.TANDY - Notary Public,State Of New York No. 01TA6086001 Qualified In Suffolk County Commission Expires 01/13/20- -,sof lfr) Town Hall Annex all • Ail Telephone(631)765-1802 54375 Main Road y P.O.Box 1179 �\ Q (&31)76 �5Q� rocienrichertCd townsou o .nv.us Southold,NY 11971-0959 ss-..1> . "0" BUILDING DEPARTMENT TOWN OF SOUTHOLD APPLICATION FOR ELECTRICAL INSPECTION • i REQUESTED BY: Company Name: red-e62 r4egy P�IGi Name: Old'A1407 /4/02 I1ei License No.: Lf7 1 f2c Address: 747u awe/ 4z'. M,lMic/ci. Al [IMP- . • Phone No.: 69779-ziOGY - JOBSITE INFORMATION: (*Indicates required information) *Name: &((k6 2rW) *Address: 0V1,05 ionli",{ t nyi jP ambit], M1/ 07/ *Cross Street: *Phone No.: al./K-yD 7/ Permit No.: 3 (� Tax•Map District: 1000 Section: 5a Block: ' Lot: *BRIEF� DESCRIPTION OF WORK(Please Print Clearly) > (4Ovurled S)la✓ PV Arra y' (Please Circle All That Apply) *Is job ready for inspection: YES! NO Rough In Final *Do you need a Temp Certificate: 440. O Temp Information (If needed) *Service Size: 1 Phase 3Phase 100 150 200 300 350 400 Other *New Service: Re-connect Underground Number of Meters Change of Service Overhead Additional Information: PAYMENT DUE WITH APPLICATION 82-Request for Inspection Form /,'�� Town Hall Annex h Telephone(631)765-1802 54375 Main Road 41g Fax(631)765-9502 P.O.Box 1179 G Q Southold,NY 11971-0959 ® �, May5, 2015 • ' l'tCOUNTI,�'C''' BUILDING DEPARTMENT TOWN OF SOUTHOLD Bruce Anderson 2265 Long Creek Dr Southold NY 11971 TO WHOM IT MAY CONCERN: The Following Items(if Checked)Are Needed To Complete Your Certificate of Occupancy: O y / OTE: Certification by an Architect or Engineer stating the panels were installed to the roof per NYS VC)* uilding Code is required Application for Certificate of Occupancy. (Enclosed) Electrical Underwriters Certificate. A fee of$50.00. Final Health Department Approval. Plumbers Solder Certificate. (All permits involving plumbing after 411/84) Trustees Certificate of Compliance. (Town Trustees#765-1892) Final Planning Board Approval. (Planning#765-1938) Final Fire Inspection from Fire Marshall. Final Landmark Preservation approval. Final inspection by Building Dept. Final Storm Water Runoff Approval from Town Engineer BUILDING PERMIT — 37633 - Solar Panels 10-19-12; 13:20 ; 4665200 ; # 1/ 1 POND SH AMOW A _180• —73 f w.\. t 6°0NF N•? r 1,514° • • l p� - y\E WOE ` tooµ Va LA sow a 4 0.e:1 o 94 .,,p,B til3:11-, r ..r.:-.Y,5 S " . ?:-‘i. ./ frNE a tr. . u )4,— '- efb w O0 �l �-- / 09 woo yr SR.tµ g a, - S" s o/ • tag• y Y'`_ 1_0's; 3 N to v µe aQ,o�rp . a08 r- pi °`°'levlk °�'aa4,, ,p _r - g 00 g gem pabMe�� 0. oe' dovsE '�, . Z, f�0• R \ so, 'L ,.. 401 5 TJ , \ ` .0 .. co ts1 \ / e,..3' 61 W \ OQ 91 sc.1 E 1 \ ` 439' '1 44\0 �µ°. , 0 5 \ 03� 50.)y� 0."*A pe NI 101' S. „LEI 1 O L °v,e \ , 4S� ,r° ,k0 990 e00.)e C•i 6 ,^ 0 G , W e•,... .4 ,v vON Oa°` a 0.M 88-50- 789 a°o _ Q • J SURVEY OF \ 9..3:11.6 NAM.00•'Jo'e/wee. AREA a 37.324 SQ.FT. 'LOT 4 ' • AM.00 wee. to• t. tie line "MAP OF LONG POND ESTATES n SECTION ONE FILED DEC. 27, 1985 FILE NO.8037 CERTIFIED' ror COMMONWEALTH14H8 INSURANCE COMPANY AT SOUTHOLD 8THOV3BqK MOWINGY/ERPRI8ES. INCORPORATED TOWN OF SOUTHOL D Prayared!a oeeareaace with me anknom SUFFOUS COUN1Y DEPARTMENTOF HEALTH SERVIC ` LK COU NTY,N.Y. shofeds ler lilt.surveys es egleensAed 1000 082 - 08 04 by!ha 1..tb-L S.we os saved ane aeoplod �S'I? AOLC FAMILY(MAIM ONLY • lar svah ere' H ronl Stole Grano DAT _ 1IYY,j�d_r�I.S,P.CF NO. lit„SA Ifa4 Yulo.e-•.0:`.NOS. 'They±v,o�'snc:��,n Q CALE I�� a 30� ty G 4 6 2 1 nr._ly kr:Wt.i r for Iters y <:MEr A` I,1 EFT.6, 1986 •'�11 ? �\ 1':I=e:C:��r�e; 7U;1Y1:•iN•::'h Lr,Cht d11U/Lf if S. LIC. NO. 496:1§sa,,.m�r�tti,r, Acna' ,. EC. 7, 1981)(certify), �' f � ' Y. hsI"s �' Jan, 17. 19891founditlon location) • // J r�r ''''' EY dd 1 P.C. i • IL-- Mir. 6,, 1989(fln8/1 -I- ' ^k rw: ii Mel al Or eau nr Nasteraler Klansment P\j' 7,�''i 9.9 qt°/ 50 ` I97r a0� CONTOUR LINE A ELEVATIONS ARE 'ror; . `�,T,I, REFERENCED TO N.O.V. DATUM IL-C-a8. ReWe' //Out& tap. , D.le. ES - 560 -GENERAL NOTES Roof Section A Subject roof has no more than one layer mean roof height 22 ft Panels mounted flush to roof no higher than 6 inches above surface. pitch 7 in/12 1. CONTRACTOR SHALL CHECK AND VERIFY ALL CONDITIONS AT THE 11.THE OWNER SHALL SELECT ALL FINISH MATERIALS AND COLORS. roof rafter 2x8 • SITE PRIOR TO STARTING TO WORK AND SHALL FAMILIARIZE 12.THESE DRAWINGS AS INSTRUMENTS OF SERVICE ARE AND SHALL HIMSELF WITH THE INTENT OF THESE PLANS AND MAKE WORK REMAIN THE PROPERTY OF THE ENGINEER WHETHER THE PROJECT rafter spacing 16 in OC AGREE WITH SAME. FOR WHICH THEY ARE MADE IS EXECUTED OR NOT.THEY ARE Reflected roof rafters an 13 8 ft 2. CONTRACTOR OR OWNER SMALL OBTAIN ALL REQUIRED APPROVALS, NOT TO BE USED ON ANY OTHER PROJECTS OR EXTENSIONS TO p PERMITS,CERTIFICATES OF OCCUPANCY,INSPECTION THIS PROJECT EXCEPT BY AGREEMENT IN WRITING AND WITH Table R802 5.1(1) max allowable 16.8 ft APPROVALS,ETC.FOR WORK PERFORMED FROM AGENCIES HAVING APPROPRIATE COMPENSATION TO THE ENGINEER. JURISDICTION THEREOF,IF REQUIRED. 13 CONTRACTOR SHALL PROTECT,PATCH AND REPALRALL EXISTING WORKADJACENTTO HIS WORK, 3 ALL WORK SHALL CONFORM TO CONSTRUCTION CODE AND CR DAMAGED AS RESULT OF HIS WORK. ALL RULES AND REGULATIONS OP THE RESPONSIBLEJURISTICTlON 14.THE SUBCONTRACTORS SHALL PROVIDEALLEQUIPMENT,TOOLS,FENCES,TRANSPORTATIONS, 4. ALL METHODS OF CONSTRUCTION ARE TO BE CAREFULLY SAFEGUARDS,ETC.,AS REQUIRED FOR THE PROPER EXECUTION OF THEIR WORK. NTHECSUPERVISED BY THE CONTRACTOR. R. 15 CONTRACTOR TO EFFECT AND MAINTAIN INSURANCE.I E.CONTRACTORS LIABILITY,WORKMAN'S �/'�` 5 IF IN THE COURSE OF CONSTRUCTION A TEDCONON THONESE EXISTS PL COMPENSATION.COMPLETED OPERATION.ETC.ADEQUATE FOR THE RURPOSES 0=THIS PROJECTAND 1%1% OCCUPANCY Li PATHE CONTRACTOR SHALL STOP WORK AND NOTIFY THE ENGINEER. €P. 1 SHOULD HE FAIL TO FOLLOW THIS PROCEDURE AND CONTINUE 16 EACH SUBCONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING SAFETY ON THE JOB SITE DURING WITH THE WORK,HE SHALL ASSUME ALL RESPONSIBILITY AND THE CONSTRUCTION PHASE TO COMPLY WITH THE REGUl.ATIONSAND REQUIREMENTS OFTHE �.--.- F�_ I 9��, F Isg LIABILITY THEREFROM. OCCLPAIIONAL SAFETY AND HEALTH ADMINISTRATION.THIS SHAD.INCLUDE BUT ARE NOT LIMITED TO' 12 , ./'"" J k� li_. UNI vile E ,5f 6. ALL STRUCTURAL STEEL SHALL BE A-36 AND SHALL.BE PROVIDING FOR ADEQUATE AND PROPER BRACING,SAFETY RAILINGS AND SECURS FOOTINGS FORAM ® /� - 9 6�f� FABRICATED AND INSTALLED AS PER LATEST AIS.C. TEMPORARY SCAFFOLDING,STAIRS,ETC,AS WELL AS PERMANENT CONSTRUCTION. \ q lC,"=t "`iV a"--_ -'% t.� SPECIFICATIONS. 17 FIGURED DIMENSIONS SHALL GOVERN.DO NOT SCALE DRAWINGS.WHERE DIMENSIONS ARE ` E Q ET_ 1lith e F _ a`�c "I 7. ALL DRYWALL SHALL BE U.S.G.NATIONAL GYPSUM CO 5/8" ESTABLISHED BY EXISTING CONDITIONS,EACH CONTRACTOR SHALL VERIFY EXISTING CONDITIONS i "�`...e t I THICK UNLESS OTHERWISE NOTED. PRIER TO ORDERING MATERIALS AND COMMENCING WITH WORK. N!./, I=mo p[er�^^ n �„�,Cp qy 8. ALL ELECTRICAL WORK SHALL BE BOARD OF FIRE UNDERWRITERS 18 CONTRACTOR SHALL COORDINATE AU.PHASES OR WORK WITH THE REQUIRED PARTIES.ALL —�' 'U r� c s 3 ii n A g'J C cP APPROVED AND IN ACCORDANCE WITH N.E.C.&NYS PHASES OF ADJACENT FACILITIES OPERATIONS SHALL BE MAINTAINED DURING CONSTRUCTION CODES& REGULATIONS. CONTRACTOR SHALL KEEP SITE FREE OF CONSTRUCTION DEBRIS AND KEEP SITE FULLY ACCESSIBLE _r, 9. ANY DEVIATION FROM THESE PLANS WITHOUT THE WRITTEN S]•vE QET. 1 CONSENT OF THE ENGINEER WILL NEGATE THE ENGINEER'S TO THE PUBLIC DURING HOURS OF OPERATION. CERTIFICATION OF THESE PLANS. 19 CONTRACTOR TO REVOVEALL DEBRIS CREATED BY THIS WORK FROM THE SITE AND DISPOSE OF 0 c c 10.THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR CUTTING. IN A LEGAL MANN ER ON AWEEKLY BASIS OR SOONER IF CONDITIONS WARRANT. Roof OI 11 ssSection FITTING OR PATCHING REQUIRED TO COMPLETE THE WORK OR TO 20 AT THE COMPLETION OF WORK,THE SITE IS TO BE CLEARED OF ALL DEBRIS AND EXCESS MAKE IT'S PARTS FIT TOGETHER PROPERLY. MATERIALS THE FACILITY IS TO BE LEFT BROOM CLEAN AND WORK IS TO BE COMPLETED TO N T S THE TOTAL SATISFACTION OF THE OWNER PRIOR TO RELEASE OF FINAL PAYMENT. o ,A NOTED FROM ` � � �; l - `.„ - DATE ���— #3 7i-13 sem} "a ```. `., ! / ` ` I" INVERTER- , FEE C�• BY �� , a-r Z 4 s i s ` ' �` . f 4 , =. NOTIFY BUILDING CJEPL RTMENT AT `` 765-1802 8 AM TC 4 PM FOR THE �,'`r . ,r Tr FOLLOWING INSPECTIONS = 3 := °,--,-4,„, _ . ; ; -4 . 4 • WRING D.—. 1 FOUNDATION -TWO EOU IRED c FOR POURED CONCRETE f �. " - 4, -n , 2 ROUGH-FRAMINGPLUMBING,4 4a PANELSTRAPPING, ELECTRICAL&CAULKI NG- - AC 021I 3 INSULATION .. ?"` % ` < 4 FINAL-CONSTRUCTION &ELECTRICAL -45----4-1_,=-. -a , 5 MUST BE COMPLETE FOR C O .` .. Clomp ` = `B PIC'AL RISER DIAGRAM ALL CONSTRUCTION SHALL MEET THE I- , =; '-=1 == § ,- _ ` N.T.S. REQUIREMENTS OF THE CODES OF NEW ' =--=-,-- <" YORK STATE. NOT RESPONSIBLE FOR `' A zn. ` .i DESIGN OR CONSTRUCTION ERRORS RISER DIAGRAM SHOWN FOR REFERENCE raii,,"lor r=r:. ...---„i.Erp, ,,L,, SolirMotsnt Rog / ,.� _ ,,,7z-q..,,,, B Revision 5 n t a xg; L�ar b a� _,_. "'...> >; , To my best belief and information the work in this document is accurate, conforms with the Revision 4 `` 4 ' --,' SdattAount Rca I governing codes applicable at the time of submission, conforms with reasonable standards Revision 3 TYPICAL CONNECTION DETAIL 1- ALL. ROOF PENETRATIONS ARE TO BE SEALED of practice, with the view to the safeguarding of life, health, property and public welfare, Revision 2 PV PANEL WITH SIKAFLEX OR EQUIVALENT SEALANT Section: 52 and is the responsibility of the licensee. Revision 1 Professional Seal: as per ASCE7, Method 1: A (fig 6-2) 1.314 I (table 6-1) 1 Block: 8 ESV PA IFI O ENGINEERING P P net =A Ka 1 P net3o (eq 6-2) Krt(sec 6 5 7) 1 Pnet3D(fig 6-3) -25.9 ' Lot: 4 $0 ��R _' 700 LakelavLd Ave, Suite 213, Bohemia, NY 1171(0 MORE/c CLIMACTIC AND Ground Wind Speed, Live load, Maximim �� Q� O Tel: 631-988-0000 Fax: 631-382-8236 Email: engivleer@pacificoevlgivleerivlg.cow p point pullout fastener h� d 6- Solar Projectfor Sneer GEOGRAPHIC DESIGN Category Snow Load, 3 sec gust, pnet30 per load, lb Fastener type spacing along CO �• W Bruce Anderson A CRITERIA Pg mph ASCE 7,psf rails,In ar•,qg �, Z Roof Section A C 20 120 35 377 5/16"dia screw, 3-1/2" length 48 �«, b`4.111_7; ..' ). 'j. 2265 Long Creek Drive, Southold, NY ' / p t.(/ Project Descnpdon. S ' 001-.00 bei, � LAR ENERGY INSTALLATION 6-1 06 Qv PROPOSED SOL-AR Draw,ng Desenptan. FD PRpF ESS\® GENERAL NOTES, ROOF SECTION, DATA, DETAILS AND SPECS Ralph Pac'H •rofes to Engineer Date Sean NY 066182/NJ 24GE04744306 20/09/22 AS NOTED 1 of 2 i DISCONNECT P / ` "V z 18" CLEAR PATH'f/ z , IIi ii 1 {T: T: it 1 }H-ili I i If 4 1 :l II �[� HILL! i ill Eli 1 l I I I r " 1 --I � .CAP7At71�iN dAt�i�At� G��Dllrl6AR C r' SOLAR—SOLAR—SOLAR_-SOLAR—SOAR -SOLAR_._SOLAR—SOLAR—SOLAR= PROPOSED SOLAR INSTALLATION -CS6P-245-CS6P-245 -CS6P-?45CS6P-245-CS6P-245-CS6P-245-A CS6P-245-CS6P-245-CS6P-245- I , x; 1 ; , I . ii„ FLUSH MOUNTED Zb / i ii Lit; , :1 �. i til ' t .ii . . l�ii`;} `' CA oiAti cRt of t1 CANAIIA s- yr:..f:1' .,r.a,. .rf.• ry5 . y, lx.. :It s,1 .-vr.*11 - r t P F I 1•E t ; i UNE- �. . --SOLAR—SOLAR- SOLAR SOLAR—SOLAR—SOLAR=SOLAR--SOLAR SOLAR -C SOLAR -CSOL2R5- CS6P-245-CS6P-245 CS6P-245-CS6P?45 CS6P-245-.CS6P-245 CS6P-245 } , 1 III rd 11 lid ,/ H i 1 !; , 1 T• I11i Ti I1 41 ;,-- i �. tt I, l ; r, f rt .i 1 1 lull{ iii€lii _' § § ' 2 " It i J_ f : -n i' ,r.iv-x : l1-:Tit .if.*,,t .1rs}-IN . ._ r( ►V+S . M.I::, . rf;e.I Ti a r.. , ,,r=s} ,,, -SOLAR=SOLAR=SOLAR=SOLAR=SOLAR=SOLAR-=SOLAR=SOLAR=SOLAR= CS6P-245- CS6P 245 CS6P-245-CSj6P-245-CS6P-245- CS6P-245- CS6P-245-CS6P-245=CS6P-245- c' I jl-F a1# T -1 1 1I I iiij - 4114;11 1, 4 , i x ' J 1 . 1 ti ` I ' 1 wit � I 1. f: , ii r ' : . ' ii . F. w it _0H I 1 i , -II 1, 1 �}, �Y 471,71A 33'_0" / Professional Seal: ROOF LAYOUT r PACIFICO ENGINEERING PC PV Panel ®� CIFJ CRS • 2 700 Lakeland Ave, Suite 2.13, Bohemia, NY 11716 A /��' .?.? C0 '" Tel: 631-988-0000 Fax: 631-382-8236 Email: ev<gineer@pacificoevtgivteeriv�g.covin Solar Project for sheet Solar CS6P- I-- `a' + a W co ;+ .- \ z) Bruce Anderson PANEL: 245 �„ . QTY. 27 #4.,,_�,i J� ;' z• 2265 Lovtg Creek Drive, Southold, NY —002-00 OO n .DD `j 0, -''' / pro,„,,,,—,,,on. S LENGTH. 64.5 in 0� 1$� P PROPOSED SOLAR ENERGY INSTALLATION /- I have reviewed the roofing structure at the subject address The structure can support the additional weight It 066 066 02 Draw ng DeecnPt on of the roof mounted system The units are to be installed in accordance with the manufacturer's installation WIDTH: 38 7 in FO ppF E. GENERAL GENERAL NOTES, ROOF SECTION, DATA, DETAILS AND SPECS instructions I have determined that the installation will meet the requirements of the 2010 NYS Building Ralph Paci _ -rn io.:a gineer Date Seale Code,and ASCE7-05 when installed in accordance with the manufacturer's instructions WATTS- 6615 NY 066182/NJ 24GE04744306 20/09/12 AS NOTED 2 of 2