Loading...
HomeMy WebLinkAbout38549-ZN Town of Southold P.O. Box 1179 53095 Main Rd Southold, New York 11971 CERTIFICATE OF OCCUPANCY 6/16/2015 No: 37606 Date: 6/16/2015 THIS CERTIFIES that the building RESIDENTIAL NEW CONSTRUCTION Location of Property: 1040 Founders Path, Southold SCTM #: 473889 Sec/Block/Lot: 64.-2-15 Subdivision: Filed Map No. conforms substantially to the Application for Building Permit heretofore 11/8/2013 pursuant to which Building Permit No. Lot No. filed in this office dated 38549 dated 12/6/2013 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: ADDITIONS AND ALTERATIONS TO AN NON -HABITABLE ACCESSORY GARAGE AS APPLIED FOR PER ZBA DECISION #6561, DATED 05-17-2012 The certificate is issued to Smith, Justin & Smith, Susan of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. PLUMBERS CERTIFICATION DATED A e Signa ure (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit #: 38549 Date: 12/6/2013 Permission is hereby granted to: Smith, Justin & Smith, Susan 1040 Founders Path Southold, NY 11971 To: construct a accessory garage addition/alteration per ZBA decision #6561 as applied for At premises located at: 1040 Founders Path, Southold SCTM # 473889 Sec/Block/Lot # 64.-2-15 Pursuant to application dated 11/8/2013 and approved by the Building. Inspector. To expire on 6/7/2015. Fees: ACCESSORY CO - ACCESSORY BUILDING Total: Building Inspector $311.20 $50.00 $361.20 TOWN OF SOUTHOLD �� Ly BUILDING DEPARTMENT TOWN CLERK'S OFFICE oy SOUTHOLD, NY o� BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit #: 38549 Date: 12/6/2013 Permission is hereby granted to: Smith, Justin & Smith, Susan 1040 Founders Path Southold, NY 11971 To: construct a accessory garage addition/alteration per ZBA decision #6561 as applied for At premises located at: 1040 Founders Path, Southold SCTM # 473889 Sec/Block/Lot # 64.-2-15 Pursuant to application dated 11/8/2013 and approved by the Building. Inspector. To expire on 6/7/2015. Fees: ACCESSORY CO - ACCESSORY BUILDING Total: Building Inspector $311.20 $50.00 $361.20 Form No_ 6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HXLL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be. filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings, property lines, streets, and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage -disposal (S-9 form). 3. Approval of'electrical installation from Board of Fire Underwriters. 4. 'Sworn statement from plumber certifying that the solder used in system contains less'than 2/10 of 1% lead. 5. Commercial building, industrial building, multiple residences and similar buildings and installations, a certificate of Code Compliance fiom.architect or engineer responsible for the building. 6. Submit' Planning Bbard A' val-of completed site plan requirements. 8. For existing build ings`(prioko-'.APril 9,-1957)'non-conforming uses, or buildings and "pre-existing" land uses: 1. Accurate survey of property showing all property lines, streets, building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied, the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees I. Certificate of Occupancy - New dwelling $50.00, Additions to dwelling $550.00,.AIterations to dwelling $50.00, Swimming pool $50.00, Accessory building $50.00, Additions to accessory buildingS50.00, Businesses $50.00. 2. Certificate of Occupancy on Pre-existing Building - $100.00 3. Copy of Certificate of Occupancy - $.25 4. Updated Certificate of Occupancy - $50.00 .5. Temporary Certificate of. Occupancy - Residential $15.00, Commercial $15.00 Date. New Construction: Old or Pre-existing Building: c (check one) J(. Location of Property: /!�Q'/%� SQ Q % AO House No. / Street Hamlet Hamlet X Owner or Owners of Property:. r`/ S/ -fl/– 7, c /y'/SAA / T! / /1 544, 5a' 17 /q. �Suffolk County Tax Map No 1000, Section. l D y Blo7e,ck 2 Lot' Subdivision :)~fled Map. Lot: Permit No. $�j� Date of Permit. Applicant: Health Dept. Apprdval: Underwriters Approval: Planning Board -Approval: . Request for: Temporary.Cerfificate• Final Certificate: (check on Fee Submitted: $- X Applicant Signature rjf so TOWN. OF SOUTHOLD BUILDINGDEPT. 765-1802 INSPECTION� FOUNDATION IST FOUNDATION 2ND FRAMING/ STRAPPING FIREPLACE & CHIMNEY FIRE RESISTMT CONSTRUCTION ELECTRICAL (ROUGH) CODE VIOLATION R F M A R K -%!! ROUG LUMBING I ULATION FINAL FIRE SAFETY INSPECTION ]FIRE RESISTMT PENETRATION ELECTRICAL (FINAL) CAULKING DATE - 6 /J/ - INSPECTOR o TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION. ] FOUNDATION 1 ST ] FOUNDATION 2ND ] FRAMING/ STRAPPING ] FIREPLACE A CHIMNEY ] FIRE RESISTANT CONSTRUCTION ] ELECTRICAL (ROUGH) ] CODE VIOLATION nIffww w MBriff-k_ [ ]ROUGH PLUMBING [ ] INSU TION 4 NAL. C ]FIRE SAFETY INSPECTION [ ]FIRE RESISTANT PENETRATION C l ELECTRICAL (FINAL) [ ]CAULKING DATE 0 `'� 1 INSPECTOR SECB PROFESSIONAL ENGINEER 1725 HOBART ROAD / PO Box 616 SOUTHOLD, NEW YORK 11971 TEL: 631.765.2954 • FAX: 631.614.3516 • e-mail: Joseph@fischetti.com Date: - 10 June 2015 Reference: BP#38549Z Building Inspector Southold Town Main Road Southold, NY 11971 Dear Sir, I have inspected the- accessory structure for the- above referenced Building Permit for the Smiths on Founders Path during construction. Specifically I inspected the windstorm strappings and the framing. I certify to the best of my knowledge that the structure has been built in accordance with New York State Building Codes. na.AW7 BOARD CERTIFIED IN STRUCTURAL ENGINEERING Ti OWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL SOUTHOLD, NY 11971 TEL: (631) 765-1802 FAX: (631) 765-9502 SoutholdTown.NorthFork.net Examined % 2043 Approved l - P, 20 /3 Disapproved a/c BUILDING PERMIT APPLICATION CHECKLIST PERMIT NO. *, F LI! NOV V 8 2013 i 1 E;f OD DEPT. Expiration C 1p, 20 1S Building Inspector Do you have or need the following, before applying? Board of Health 4 sets of Building Plans_ Planning Board approval Survey Check Septic Form N.Y.S.D.E.C. Trustees C.O. Application_ Flood Permit Single & Separate Storm -Water Assessment Form ntact: Mail to: Phone: / G 5— Vy APPLICATION FOR BUILDING PERMIT --'\ Date I ( 520 )3 INSTRUCTIONS a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans, accurate plot plan to scale. Fee according to schedule. b. Plot plan showing location of lot and of buildings on premises, relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application, the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e. No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim, the Building Inspector may authorize, in writing, the extension of the permit for an addition six months. Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County, New York, and other applicable Laws, Ordinances or Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances, building code, housing code, and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. �A (Signature of applicant or name, if a corporation) 1070 (Mailing address oPapplicant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder Dam e'o Name of owner of premises JUV:/ / J I • m/ A# 4/ San Al (As on the tax roll or latest deed) If applicant is a ectrporation, signature of duly authorized officer (Name and title of corporate officer) Builders License No. 1 / Plumbers License No. ApP l! r-nw"/ C;5 Electricians License No. rT Other Trade's License No. 1. Location of land on which proposed work will be House Number Street Hamlet County Tax Map No. 1000 Section Block 2 Lot % 5. Subdivision 2. State existing use and occupancy of pr rises a. Existing use and occupancy G • -b Filed Map No. Lot int%ded use and occupancy of proposed construction: ;e lltq b. Intended use and occupancy #Cc • 7� h kV`/ 3. Nature of work (check which applicable): New Building Addition Repair Removal Demolition Other Work 9 e r 4. Estimated Cost 20, 006 k-trf �" - Fee l Alteration (Description) (To be paid on filing this application) 5. If dwelling, number of dwelling units Number of dwelling units on each floor_ If garage, number of cars 2.. 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. X7 Dimensions of existing structures, if any: Front Rear Height , . Number of Stories Dimensions of same structure with alterations or additions: Front Depth Height. Number of Stories Depth X 8. Dimensions of entire new construction: Front Rear Depth Height Number of Stories 9. Size of lot: Front Rear Depth 10. Date of Purchase Name of Former Owner 11. Zone or use district in which premises are situated A. Rear 12. Does proposed construction violate any zoning law, ordinance or regulation? YES NO 13. Will lot be re -graded? YES NO�Will excess fill be removed from premises? YES NOI r � 14. Names of�h remises)y5"a 011.5 sPI�i dress ®�O f®tf �/��&� %4 hone No. Name of Itect 1`)S• 56,S Address_ 6 bth-f6 d Phone No Name of Contractors r C fm' Address Phone No. 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO * IF YES, SOUTHOLD TOWN TRUSTEES & D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO ( * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey, to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. 18. Are there any covenants and restrictions with respect to this property? * YES NO * IF YES, PROVIDE A COPY. X STATE OF NEW YORK) SS: COUN fTY OF / X (/L % — being duly sworn, deposes and says that (s)he is the applicant (Name of individual signing contract) above named, (S)He is the (Contractor, Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief, and that the work will be performed in the manner set forth in the application filed therewith. Sworn to before me this day of _ 20 Notary Public Signature of Applicant FORM NO. 3 NOTICE OF DISAPPROVAL DATE: July 29, 2011. Updated: March 20, 2012 TO: Joseph Fischetti for Justin & Susan Smith P O Box 616 Southold, NY 11971 Please take notice that your application dated September 9, 2009 For permit for an addition & alteration to an accessory garage at Location of property 1040 Founders Path, Southold, NY County Tax Map No. 1000 - Section 64 Block 2 Lot 15 Is returned herewith and disapproved on the following grounds: The Droposed construction. to this accessory aaraae, is not Dermitted pursuant to Article IV, Section 280-18 which states: No building or premises shall be ... altered in the R40 District unless the same conforms to the reauirements of the Bulk Schedule... with the same force and effect as if such regulations were set forth herein in full. The required front yard setback for this lot is 40'. The proposed second floor setback is 34.1'. In addition, the proposed construction is not permitted pursuant to Art. III Sec. 280-15 The maximum allowable height is 22' The proposed 2nd floor addition will be 25' in height. ,12 Patricia Conklin, Permit Examiner FORM NO. 3 NOTICE OF DISAPPROVAL TO: Joseph Fischetti for Justin & Susan Smith P O Box 616 Southold, NY 11971 DATE: July 29, 2011 Updated: March 20, 2012 *Amended: April 4, 2012 Please take notice that your application dated September 9, 2009 For permit for an addition & alteration to an attached accessory garage at Location of property 1040 Founders Path, Southold, NY County Tax Map No. 1000 - Section 64 Block 2 Lot 15 Is returned herewith and disapproved on the following grounds: The proposed construction, to this attached (by breezeway) accessory garage, is not permitted pursuant to Article III, Section 280-124 which states: "This section is intended to provide minimum standards forrig of a building permit for the principal buildings of lots which are recognized ... are nonconforming and have not merged..." The required front yard setback for this lot is 40'. The proposed second floor setback is 34.1'. In addition, the proposed construction is not permitted pursuant to Art. III Sec. 280-15 The maximum allowable height is 22' The proposed 2nd floor addition will be 25' in height. Pa ricia Conklin, Permit Examiner *Amended to specify the proper code section. 41 1q BOARD MEMBERS Leslie Kanes Weisman, Chairperson James Dinizio, Jr. Gerard P. Goehringer George Horning Ken Schneider http://southoldtown.notthfork.net Southold Town Hall 53095 Main Road • P.O. Box 1179 Southold, NY 11971-0959 Office Location: Town Annex /First Floor, Capital One Bank 54375 Main Road (at Youngs Avenue) Southold, NY 11971 ZONING BOARD OF APPEALS TOWN OF SOUTHOLD Tel. (631).765-1809 • Fax (631) 765-9064 FINDINGS, DELIBERATIONS AND DETERMINATION MEETING OF MAY 17, 2012 M AY44 2012 0 DEPT. -MITHOLD ZBA FILE: 6561 NAME OF APPLICANT: Justin and Susan Smith PROPERTY LOCATION: 1040 Founders Path (corner Landon Road) Southold NY SCTM#1000-64-2-15 SEQRA DETERMINATION: The Zoning Board of Appeals has visited the property under consideration in this application and determines that this review falls under the Type II category of the State's List of Actions, without further steps under SEQRA. SUFFOLK COUNTY ADMINISTRATIVE CODE: This application was referred as required under the Suffolk County Administrative Code Sections A 14-14 to 23, and the Suffolk County Department of Planning issued its reply dated March 29, 2012 stating that this application is considered a matter for local determination as there appears to be no significant county -wide or inter -community impact. LWRP DETERMINATION: The relief, permit, or interpretation requested in this application is listed under the Minor Actions exempt list and is not subject to review under Chapter 268. PROPERTY FACTSMESCRIPTION: Subject parcel is located in the R40 zone and contains 22,111 square feet. It is improved with a one story dwelling with attached deck and garage. It has 150.00 feet of frontage on Founders Path, 146.76 feet of frontage on Landon Road, 150.00 along the west property line and 148.07 feet along the north property line as shown on the survey prepared by John T. Metzger, LLS dated May 21, 2007. BASIS OF APPLICATION: Request for Variances from Article XXIII Section 280-124 and Article III Section 280-15 based on an application for building permit and the Building Inspector's July 29, 2011, updated March 20, 2012 Notice of Disapproval concerning addition and alteration to an accessory garage attached by a breezeway, at; 1) less than the code required front yard setback of 40 feet, 2) more than the maximum height allowable of 22 feet. RELIEF REQUESTED: The applicant requests a variances to construct a second story addition to the garage with a front yard setback of 34.1 feet where the code requires 40 feet, and a height of 25 feet where the code permits a maximum height of 22 feet. FINDINGS OF FACT/ REASONS FOR BOARD ACTION: The Zoning Board of Appeals held a public hearing on this application on May 3, 2012 at which time written and oral evidence were presented. Based upon all testimony, documentation, personal inspection of the property and surrounding neighborhood, and other evidence, the Zoning Board finds the following facts to be true and relevant and makes the following findings: Page 2 of 3 —May 17, 2012 ZBA File46561 - Smith CTM: 1000-64-2-15 1. Town Law &267-b(3)(b)(1). Grant of the variance will not produce an undesirable change in the character of the neighborhood or a detriment to nearby properties because many of the existing garages and homes in the area have similar setbacks. 2. Town Law 4267-b(3)(b)(2). The benefit sought by the applicant cannot be achieved by some method, feasible for the applicant to pursue, other than an area variance because the garage already exists and granting the new roof line in order for the applicant to gain some additional storage space will not change the existing setback. 3. Town Law 4267-b(3)(b)(3). The variances granted herein are not substantial, because the existing setback will not be changed and only a very small portion, approximately 10%, of new roof will be above the maximum height required by the code. 4. Town Law &267-b(3)(b)(4)_No evidence has been submitted to suggest that a variance in this residential community will have an adverse impact on the physical or environmental conditions in the neighborhood. The physical conditions will be improved because the new roof line will be more in keeping with the roof style of the existing house. The environmental conditions will be improved because the new construction will be required to meet the current standards for controlling drainage and roof runoff. 5. Town Law §267-b(3)(b)(5). The difficulty has been self-created. The applicant purchased the parcel after the Zoning Code was in effect and it is presumed that the applicant had actual or constructive knowledge of the limitations on the use of the parcel under the Zoning Code in effect prior to or at the time of purchase. However, the board finds that adding a small space on top of the already existing garage will have a minimum effect to the neighborhood. 6. Town Law §267-b. Grant of the requested relief is the minimum action necessary and adequate to enable the applicant to enjoy the benefit of the additional storage space in their accessory garage while preserving and protecting the character of the neighborhood and the health, safety and welfare of the community. RESOLUTION OF THE BOARD: In considering all of the above factors and applying the balancing test under New York Town Law 267-B, motion was offered by Member Dinizio, seconded by Member Goehringer, and duly carried, to GRANT, the variances as applied for, and shown on the survey prepared by Peconic Surveyors PC and dated May 21, 2007 and the drawings labeled sheet 1 and 2, prepared by Joseph Fischetti P.E. dated June 5, 2011. Any deviation from the survey, site plan and/or architectural drawings cited in this decision will result in delays and/or a possible denial by the Building Department of a building permit, and may require a new application and public hearing before the Zoning Board of Appeals. Any deviation from the variances) granted herein as shown on the architectural drawings, site plan and/or survey cited above, such as alterations, extensions, or demolitions, are not authorized under this application when involving nonconformities under the zoning code. This action does not authorize or condone any current or future use, setback or other feature of the subject property that may violate the Zoning Code, other than such uses, setbacks and other features as are expressly addressed in this action. The Board reserves the right to substitute a similar design that is de minimis in nature for an alteration that does not increase the degree of nonconformity. Page 3 of 3 —May 17, 2012 ZBA File#6561 -Smith CTM: 1000-64-2-15 Vote of the Board.- Ayes: Members Weisman (Chairperson), Dinizio, Goehringer, Schneider, Horning. This Resolution was duly adopted (5-0). Leslie Kanes Weisman, Chairperson Approved for filing /2012 F Scot A. Russell SUPERVISOR SOUTHOLD TOWN HALL - P. O. Box 1179 Telephone #: (631) - 765 -1560 MICHAEL.COLLINS@TOWN.SOUTHOLD.NY.US l-\ s"'r�� James A. Richter, R.A. co Michael M. Collins, P.E. 53095 Main Road - SOUTHOLD, NEW YORK 11971 Fax #: (631) - 765 - 9015 JAMIE.RICHTER@TOWN.SOUTHOLD.NY.US .Office of the Engineer Town of Southold STORMWATER MANAGEMENT CONTROL PLAN REVIEW COVER SHEET ( TO BE COMPLETED BY THE APPLICANT) TO: ENGINEERING DEPARTMENT FROM: BUILDING DEPARTMENT DATE: g1l ( 3 APPLICANT: S.C.T.M. �— PROPERTY ADDRESS: BRIEF PROJECT DESCRIPTION: 11 PLEASE ATTACH TILE FOLLOWING DOCIIOTS or INFORMATION.- 11 ❑ Copy of completed Application for Building Permit ❑ Stormwater Management Control Plan II ❑ Completed Chapter 236 Stormwater Review Checklist - A•. ?• /c * OR EI RING DEPARTMENT USE ONLY`* Reviewed By. Date: jzGto Appr /Information Additi Required: U 20 CHAPTER 236 Stormwater Review Checklist Stormwater Management CQntroI Plan Requirements' Yes No NA Plan drawn to scale of not less than60 feet"to the inch showing: a. location and description of property.boundahes b. total site acreage c. existing and natural and manmade features on and within 500 feet of the site boundpry as required in $236-17(C)(2) d. test hole data indicating soil characteristics and the depth to water e. proposed limits of clearing and the total area of proposed land disturbance f. existing and proposed contours of the site (minimum 2' interval) g. location of all existing and proposed structures, roads, driveways, _ sidewalks, drainage improvements and utilities h. spot grade and finished floor elevations for existing and proposed structures i. location of the swimming pool discharge ring j. location of proposed soil stockpile area(s) k. location of the proposed donsxruction entrance/staging areas 1. location of the proposed:concrete washout area m. location of all proppsed erosion and sediment control measures 2. Plan includes calculations showing that the stormwater improvements are sized to capture, store and infiltrate on-site the' from all impervious surfaces generated by a two-inch rainfall 3. Detail drawings (rMired for plan apnroyal) provided for: a. erosion and sediment controls b. construction entrance c. inlet- structures (e.g. catch basins, trench drains, etc.) ,d. leaching structures (e.g. infiltration basins, swales, etc.) DATE: APPLICANT: S.C.T.M. #: PHYSICAL ADDRESS: If No or NA, Please Provide Additional Information .BYO AAA. w f66 �,, REVISED 7/24/2013 TOWN OF SOUTHOLD PROPERTY RECORD CARD 'j-0/ �WI�IER 1. SG I STREET 1 '� % ' 0/; VILLAGE DISTRICT SUB, LOT P FA 7�A y -,s L) FORMER OWNER N E ACREAGE Tit 1,A P. ,� ped. S W TYPE OF B LDING �- ����f, ' �_ Vr RES. SEAS. VL. FARM COMM. I IND. ` CB. I MISC. f LAND IMP. TOTAL DATE REMARKS 2.1 �- / S, 0 u 0 �F'°6�K=P lain W/' OOOF 4- o (V7 Cji Qx J /S -Do �(J CJ �S^Q Q ✓/l�/ c� ' �� ,r_---�. I178� 7 top.,'. 6L(C co q -- V lu Acr q3 of e o� B P 3 33� 3�'siAA a da I b ----- l2 ov. o0 y oor 9 9 23 D 6P#35017 -rces 333 Co Till j®C3- EV ✓ /f a Q . PAie House Nt. — ✓ Teta I 64.72-15 2/10 --------- --- , ) '� . I C. K Foundation Both -Bg. 2M.ld 7q 17 Oy asernent Floors Extension Ext. Wails -!�4 n Finish Interior Fiis h Extension S-0 ExtUl& ,1 q fr)l V_ 1-7 JS .77, Fire Place ---rAtVc Heat 'N V Anvt,�� Porch —009. , DEA1, :57Z)D11) L,4VYb 7 --, 09 10 -0 _PV,� Rooms Ist Floor ms 1st Rooms S ,570 y .6-- Ig Patio V:iv R 2 Rooms 2nd Floor 'DG Breezewo 14 Driveway D r Driveway y '7 Garage O. B. 5 °�4 K LOT NUMBERS REFER TO "FOUNDERS ESTATES" FILED IN THE SUFFOLK COUNTY CLERK'S OFFICE ON MA Y 10, 1927 AS FILE NO. 834. 'THE LOCATION OF ,SEPTIC SYSTEM SHOWN HERON ARE FROM FIELD OBSERVA TIONS ' AND / OR DATA OBTAINED FROM 0 THERS. 4 LOT COVERAGE HOUSE, GARAGE,. DECK, METAL FR. BLDG. &. SHED/ 2643 4q.tl. 2643/221 /1 12.4 AREA=22,111 80. FT. SURVEY OF PROPERTY A T SO UTHOLD TOWN OF S UTHOLD SUFFOLK COUNTY, N. Y. . 1000-6��rr4-./0,2-/1� 5 Sli1L E. 1 '=3V MAY 21, 2007 SEPT. I, 20/1 (LOT COVERAGE; RA I W A66 fog- pn 8�o(�v14-�- Mvv. LU4Tc -- \ ZBA�g AL MAP SEE DECISION # p U/ Fl CA Tlo"') Of DRAB W)&t T � 5Toq (�ATi()� � ' Y, u � 1 �- ■ =MONUMENT ANY ALTERA770N 00R ADDITION TO THIS SURVEY IS A .VIOLATION OF SEC 77ON 7209f THE NEW YORK STATE EDUCAT70N LAW. EXCEPT AS PER 9EC77ON 7209 -SUBDIVISION 2. -ALL CERTIFICA77ONS HEREON. ARE VALID FOR THIS MAP AND COPIES THEREOF ON64' IF SAID MAP OR COPIES BEAR 7HE IMPRESSED SEAL OF THE SURVEYOR WHOSE SIGNATURE APPEARS HEREON. - N0. 49618 ECONI C S YORS, P.C. (631) 765-5020 FAX (631) 765-1797 P.O. BOX 909 1230 TRAVELER STREET ry SOUTHOLD, N.Y 11971 07-155a —155 LOT NUMBERS REFER TO "FOUNDERS ESTATES" FILED IN THE SUFFOLK COUNTY CLERK'S OFFICE ON MAY 10, 1,927 AS FILE NO. 834. THE LOCATION OF ,5EPTIC- SYSTEM SHOWN HERON ARE FROM FIELD OBSERVATIONS- AND , / OR DATA OBTAINED FROM 0 THERS. "o 1 SASE• 10o F vol 32 .,R pR- Cid / Pj0 `� 0•B' O X fps Sc 9c Gp1pLFR Vol 2 Ma o� p� D go FE ,Yj 1.2 LOT COVERAGE ' HOUSE, GARAGE, DECK, METAL FR. BLDG. 2643 .5q. fl. 2643/22111 = 12.4 AREA=227111 SQ. FT. SURVEY OF PROPERTY A T SO UTHOLD TOWN OF SO UTHOLD SUFFOLK CO UNT Y, N. Y. 1000-64-02-15 SCALE: 1'=30' MAY 21, 2007 SEPT. 1, 2011 (LOT COVERAGE) \ ZBA AL MAP SEE DECISION7# ��Lo t rolop ■ =MONUMENT ANY AL TERA 770N OR ADDITION TO THIS SURVEY IS A . VIOLATION OF SECTION 7269OF THE NEW YORK ST47F EDUCATION LAW. EXCEPT AS PER SECTION 7209 -SUBDIVISION 2. ALL CERTIFICA77ONS HEREON ARE VALID FOR THIS MAP AND COPIES THEREOF ON&Y IF SAID MAP OR COPIES BEAR 7HE IMPRESSED SEAL OF THE SURVEYOR WHOSE SIGNATURE APPEARS HEREON. i 49618 ECONIC SOPVEYORS, P. C (631) 765-5020 FAX (631) 765-1797 P.O. BOX 909 1230 TRAVELER STREET SOUTHOLD, N. Y. 11971 ��-155 REAR ELEVATION SCALE: 1/4•• = 1•-011 LEFT ELEVATION FRONT ELEVATION SCALE: 1/4" = 1'-0" RIGHT ELEVATION SCALE: 1/4" = 1'-0" AP P vVED AS N T L' DATE �°Z B.P.:`_� FEE_ -2-IL, Ry' NOTIFY BU!LQiN,- ' f C Y i Fci���I�.J.r\�.7 ii�ili�['�. . P " 'Li k0U , r r., "q r G ELL F „ Iw 3. INSULATION 4. FINAL - CONSTRUCTION & ELL:` rt MUST BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NE,,' YORK STATE, NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS 9ETAIN STORM WATER RUNO PURSUANT TO CHAPTER 236 .'<)f THE TOWN CODE. cn Z O H cr W F- J Q zm cn Z O H F— H 0 Q ZBA FINAL MAP SEE DECISION WN BY: JF/MH :.`. June 05, 2011 SCALE: NTS SHEET NO: 12" x10 STAINLESS STEEL OR GALVANIZED WOOD SCREWS W/ WASHERS • 12" O.C. SECTION A -A SCALE: 1/4" = 1'-0" I2"OC 2x4 DFx2 STUDS --i #10 STAINLESS STEEL OR GALVANIZED WOOD SCREWS W/ WASHERS * 12" O.C. IR" APA RATIO SHEATHING — GRADE PLYWOOD (ALTERNATMVE: 7/1♦" O.SA.) M"OC 4" 17 WINDOW SILL 4" D = 7 i i !1 I I Y I 1 I i I CL I I it II Y I Ii rIl � I r I! l r �I 1 'I I 1 11 T I I, •� i i I �wI I I I I C I � I I ��� ��____ �_ - p •� 3,-811 j I2"OC 2x4 DFx2 STUDS --i #10 STAINLESS STEEL OR GALVANIZED WOOD SCREWS W/ WASHERS * 12" O.C. IR" APA RATIO SHEATHING — GRADE PLYWOOD (ALTERNATMVE: 7/1♦" O.SA.) M"OC 4" 17 WINDOW SILL 4" D MULTIPLE PLYWOOD ASSEMBLIES 2.2X4 DFl2 STUDS CONNECTED TOGETHER WITH STAINLESS STEEL OR GALVANIZED DOLTS W/ WASHERS AND NUTS • T -W O.C. 31C APA PLYWOOD BATHING 0-7 #10 STAINLESS STEEL OR GALVANIZED WOOD SCREWS W/ WASHERS 9 12" D.C. CTN30-2 TW3046-2 �. (2)1-3/4X9-1/2 M� HDR. 30"AFF (fYP.)f , 1 1 i 1 1 1 1 1 /1 1 1 1 I 1 I 1 / 1 1 , 1 1 t 1 1 1 1 1 1 1 , 1 1 1 , _ _ _ _ _ _ATHEDR _ _ _ _ _ _ 0 /� CEILING 0 40 00 r4 / 1 1 \ N N , % N I 1 1 1 • I 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 , 1 1 1 1 1 1 / 30"AFF (TYP.) i \ f ` (2) 1-3/4X9-1/2 M� HDR. CTN30-2 TW3046-2 241 -OI' m 2ND. FLOOR PLAN. SCALE: 1/9" = 1'-0" ----------------------------------- ------ --------------------------- 11 II II LIED SHEATHING 1 I 12 WOOD IVIVE: 7/16" O.S.D.) 1 I2X10 DF#2 C`'1 RR @16"OC I 1 I jJ � \b I I b O 1 1 �O 1 1 I I I2 11 ce II � II II rl rl II II it I I 1-3/4X11-7 b ML RIDGE 1-3/4X11-7/8 ML RIDGE I I I I II II I 1 I I I 12 I i O 12 1 I (p II � �II w I I Jr (7 12 0 F-1 I I / 12 )k+ L II \ a tiN, � I 1 M RR @16"OC II 11 II it-------------------------------------------------------------------- WIND-BORNE DEBRIS PROTECTION FOR WOOD STRUCTURAL PANEL AS PER TABLE 1609"1.4, N.Y.S. RES. CODE: ALTERNATIVE FOR OPENING PROTECTION (IF NOT USING IMPACT GLAZING) WINDBORNE DEBRIS PROTECTION FASTENING SCHEDULE FOR WOOD STRUCTURAL PANELS WOOD STRUCTURAL PANELS WITH A MINIMUM THICKNESS OF 7/16" AND MAXIMUM PANEL SPAN OF i FEET SHALL BE PERMITTED FOR OPENING PROTECTION IN ONE- AND TWO-STORY BUILDINGS. PANELS SHALL BE PRECUT TO COVER GLAZED OPENINGS WITH ATTACHMENT HARDWARE PROVIDED. (REFER TO SECTION 1609.1.4, 1609.6.5 AND TABLE 1609.1.4 OF N.Y.S. RESIDENTIAL CONSTRUCTION CODE). THIS IS NOT A SUBSTITUTION FOR DESIGN -PRESSURE. ALL OPENINGS MUST HAVE DESIGN -PRESSURE UPGRADES WHERE APPLICABLE. ALL PANELS MUST BE CUT TO SIZE AND READY TO USE ON ANY NEW WINDOWS AND DOORS. SHUTTERS MUST BE MARKED FOR WHAT OPENING IT IS TO COVER. HARDWARE MUST ACCOMPANY SHUTTERS FOR INSTALLATION. ROOF PLAN A SCALE: 1/4" = 1'-0" EX. DOOR = 7 1 1 1 (Yi CL I I I 1 11 T 1 �wI I I I I C ------------------------------- -------------------------------------- 1-7/8 ML w/ 1/2" STEEL FLITCH PLATE ��� ��____ �_ - p 2)1-3, 3,-811 sill M ry 1 1 1 1 1 = , I 1 1 I 1 1 1 1 1 F- I 1 1 1 1 1 1 ---------- 1 1 1 I 1 I 1 1 I (2)1-3/4X11-7/8 (2) 1-3/4X11-7/8 ML HDR. I ' (2) 1 -3/4X11 -7/d ML HDR. 1 4!® MULTIPLE PLYWOOD ASSEMBLIES 2.2X4 DFl2 STUDS CONNECTED TOGETHER WITH STAINLESS STEEL OR GALVANIZED DOLTS W/ WASHERS AND NUTS • T -W O.C. 31C APA PLYWOOD BATHING 0-7 #10 STAINLESS STEEL OR GALVANIZED WOOD SCREWS W/ WASHERS 9 12" D.C. CTN30-2 TW3046-2 �. (2)1-3/4X9-1/2 M� HDR. 30"AFF (fYP.)f , 1 1 i 1 1 1 1 1 /1 1 1 1 I 1 I 1 / 1 1 , 1 1 t 1 1 1 1 1 1 1 , 1 1 1 , _ _ _ _ _ _ATHEDR _ _ _ _ _ _ 0 /� CEILING 0 40 00 r4 / 1 1 \ N N , % N I 1 1 1 • I 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 , 1 1 1 1 1 1 / 30"AFF (TYP.) i \ f ` (2) 1-3/4X9-1/2 M� HDR. CTN30-2 TW3046-2 241 -OI' m 2ND. FLOOR PLAN. SCALE: 1/9" = 1'-0" ----------------------------------- ------ --------------------------- 11 II II LIED SHEATHING 1 I 12 WOOD IVIVE: 7/16" O.S.D.) 1 I2X10 DF#2 C`'1 RR @16"OC I 1 I jJ � \b I I b O 1 1 �O 1 1 I I I2 11 ce II � II II rl rl II II it I I 1-3/4X11-7 b ML RIDGE 1-3/4X11-7/8 ML RIDGE I I I I II II I 1 I I I 12 I i O 12 1 I (p II � �II w I I Jr (7 12 0 F-1 I I / 12 )k+ L II \ a tiN, � I 1 M RR @16"OC II 11 II it-------------------------------------------------------------------- WIND-BORNE DEBRIS PROTECTION FOR WOOD STRUCTURAL PANEL AS PER TABLE 1609"1.4, N.Y.S. RES. CODE: ALTERNATIVE FOR OPENING PROTECTION (IF NOT USING IMPACT GLAZING) WINDBORNE DEBRIS PROTECTION FASTENING SCHEDULE FOR WOOD STRUCTURAL PANELS WOOD STRUCTURAL PANELS WITH A MINIMUM THICKNESS OF 7/16" AND MAXIMUM PANEL SPAN OF i FEET SHALL BE PERMITTED FOR OPENING PROTECTION IN ONE- AND TWO-STORY BUILDINGS. PANELS SHALL BE PRECUT TO COVER GLAZED OPENINGS WITH ATTACHMENT HARDWARE PROVIDED. (REFER TO SECTION 1609.1.4, 1609.6.5 AND TABLE 1609.1.4 OF N.Y.S. RESIDENTIAL CONSTRUCTION CODE). THIS IS NOT A SUBSTITUTION FOR DESIGN -PRESSURE. ALL OPENINGS MUST HAVE DESIGN -PRESSURE UPGRADES WHERE APPLICABLE. ALL PANELS MUST BE CUT TO SIZE AND READY TO USE ON ANY NEW WINDOWS AND DOORS. SHUTTERS MUST BE MARKED FOR WHAT OPENING IT IS TO COVER. HARDWARE MUST ACCOMPANY SHUTTERS FOR INSTALLATION. ROOF PLAN A SCALE: 1/4" = 1'-0" EX. DOOR REPLACE EX. DOOR REPLACE EX. DOOR 241-011 1ST. FLOOR P O fV 1/411 = 1'-011 U) z 0 H Q cc W J Q W cn Z 0 H .IDI. 0 Q �>- 'it ZLn w � �N^ 0 O Y m = w A0 a. 0 (o U) BA FINAL MAP EE DECISION Ir/� DRAWN BY: JF/MH June 05, 2011 SCALE: NTS SHEET NO: 2 = 7 1 1 1 (Yi CL 1 11 T 1 �wI ------------------------------- -------------------------------------- 1-7/8 ML w/ 1/2" STEEL FLITCH PLATE ��� ��____ �_ - p 2)1-3, 3,-811 M ry 1 1 1 1 1 = , 1 1 1 1 1 1 1 F- I 1 1 1 1 1 1 ---------- 1 1 1 I 1 I 1 1 I (2)1-3/4X11-7/8 (2) 1-3/4X11-7/8 ML HDR. I ' (2) 1 -3/4X11 -7/d ML HDR. 1 REPLACE EX. DOOR REPLACE EX. DOOR 241-011 1ST. FLOOR P O fV 1/411 = 1'-011 U) z 0 H Q cc W J Q W cn Z 0 H .IDI. 0 Q �>- 'it ZLn w � �N^ 0 O Y m = w A0 a. 0 (o U) BA FINAL MAP EE DECISION Ir/� DRAWN BY: JF/MH June 05, 2011 SCALE: NTS SHEET NO: 2 Z O H F� H W a J w A Q A O Cn O H O H 4 D ' � Q REAR ELEVATION FRONT ELEVATION SCALE: 1/4" = 1'-0" SCALE: 1/4" = 1'-0" W Q W v� Z >- .���Z� W (o 0 N J X J Lj APPRO',7D AS NOTED Q m O p DATE !J 1 B.P. # z — // O FEE:_.ILL-9D BY cam. — O M NOTIFY BU?l !):1 ,.; D A I III III 765-1802 ; ,;,I TO 4 FOLLO',Nit, . ; '�".PECTIr"f,.;l 1. FO! !r. 2 ;Z 3. IN _AT 11-1.4 4. ALL CONSTRU"',�11C'N REQUIREMENTS OF i HE YORK STATE. NOT RESPONSIBLE FGR DESIGN OR CONSTRUCTION ERRORS, ETAIN STORM WATER RUNOFF PURSUANT TO CHAPTER 236 OF THE TOWN CODs. DRAWN BY: JF MH RIGHT ELEVATION' w June 05 20 LEFT ELEVATION �� �- :.t -� 11 °.. ,r SCALE: 1/4" = 1'-0" SCALE: 1/4" = 1'-0" SCALE: NTS t� SHEET NO: 5�� *10 STAINLESS STEEL OR GALVANIZED WOOD SCREWS W/ WASHERS • 12" O.C. SECTION A -A SCALE: 1/4" = V-0" 12"0c 2x4 DF*2 STUDS– • 4" *10 STAINLESS STEEL OR=. — WOOD SCREWS W/ WASHERS 0 12" O.C. L/2" AM RATED SHEATHING -- GRADE PLYWOOD (ALTE'RNATIWVE: 7116° O.S.B,) 4" rl i ! I I !I I I Ii I ill l 1 �I I I\ I i I I I I I I I I I III 1 1 I I II II I-----� I I iI l� 11 1 t J Mlm-- I li I i I I i i I I \ I I� � g!1 III I IBI 12"0c 2x4 DF*2 STUDS– • 4" *10 STAINLESS STEEL OR=. — WOOD SCREWS W/ WASHERS 0 12" O.C. L/2" AM RATED SHEATHING -- GRADE PLYWOOD (ALTE'RNATIWVE: 7116° O.S.B,) 4" rl WINDOW ' I I I II I II I� I I e 1 �I WINDOW ' i MULTIPLE PLYWOOD ASSEMBLIES 2 - 2X4 DFX2 STUD6 CONNECTED TOGETHER WITH STAINLESS STEEL OR GALVINIZED BOLTS W/ WASHERS AND NUTS 0 X -V D.C. 3/4" ATM PLYWOOD —SHEATHING #10 STAINLESS STEEL OR GALVANIZED WOOD SCREWS W/ WASHERS • 12" O.0 u� TvD SHEATHING GRADE PLYWOOD (ALTERNATIVIVE: 7116" O.S.S.) WIND-BORNE DEBRIS PROTECTION FOR WOOD STRUCTURAL PANEL AS PER TABLE 1609.1.4, N.Y.S. RES. CODE: ALTERNATIVE FOR OPENING PROTECTION (IF NOT USING IMPACT GLAZING) WINDBORNE DEBRIS PROTECTION FASTENING SCHEDULE FOR WOOD STRUCTURAL PANELS WOOD STRUCTURAL PANELS WITH A MINIMUM THICKNESS OF 7/161, AND MAXIMUM PANEL SPAN OF 9 FEET SHALL BE PERMITTED FOR OPENING PROTECTION IN ONE- AND TWO-STORY BUILDINGS. PANELS SHALL BE PRECUT TO COVER GLAZED OPENINGS WITH ATTACHMENT HARDWARE PROVIDED. (REFER TO SECTION 1609.1.4, 1609.6.5 AND TABLE 1609.1.4 OF N.Y.S. RESIDENTIAL CONSTRUCTION CODE). THIS IS NOT A SUBSTITUTION FOR DESIGN -PRESSURE. ALL OPENINGS MUST HAVE DESIGN -PRESSURE UPGRADES WHERE APPLICABLE. ALL PANELS MUST BE CUT TO SIZE AND READY TO USE ON ANY NEW WINDOWS AND DOORS. SHUTTERS MUST BE MARKED FOR WHAT OPENING IT IS TO COVER. HARDWARE MUST ACCOMPANY SHUTTERS FOR INSTALLATION. CTN30-2 TW3046-2 (2) 1-3/4X9-1/2 M HDR. �� 3o"AFF (TYP.) / 1 1 ` 1 I 1 1 1 1 1 /1 1 1 1 , ` 1 1 \ / 1 1 1 1 1 1 i 1 1 I 1 1 , ol 1 1 / DN \ 1 1 1 1 , T_ = 1 1 = _ _ - 4A' ED' - - - - - -N - 1 CEILING - X b X / 1 1 N N _ N ♦ ` N 1 1 1 1 ♦ 1 1 � 1 1 ♦ 1 1 � 1 1 1 1 1 1 1 1 1 1 1 1 1 t 1 1 1 , 1 1 1 1 \ / 30"AFF (TYP.) (2)1-3/4X9-1/2 X9-1/2 M� HDR. CTN30-2 TW3046-2 24' -OI' 2ND. FLOOR PLAN SCALE: 1/4•• = 1'-0" 1/4" = 1'-011 EX. DOOR 77/ 1 I i I I I I I I 4 I I III _ II II I-----� I I 'I I-- I - --� J Mlm-- i MULTIPLE PLYWOOD ASSEMBLIES 2 - 2X4 DFX2 STUD6 CONNECTED TOGETHER WITH STAINLESS STEEL OR GALVINIZED BOLTS W/ WASHERS AND NUTS 0 X -V D.C. 3/4" ATM PLYWOOD —SHEATHING #10 STAINLESS STEEL OR GALVANIZED WOOD SCREWS W/ WASHERS • 12" O.0 u� TvD SHEATHING GRADE PLYWOOD (ALTERNATIVIVE: 7116" O.S.S.) WIND-BORNE DEBRIS PROTECTION FOR WOOD STRUCTURAL PANEL AS PER TABLE 1609.1.4, N.Y.S. RES. CODE: ALTERNATIVE FOR OPENING PROTECTION (IF NOT USING IMPACT GLAZING) WINDBORNE DEBRIS PROTECTION FASTENING SCHEDULE FOR WOOD STRUCTURAL PANELS WOOD STRUCTURAL PANELS WITH A MINIMUM THICKNESS OF 7/161, AND MAXIMUM PANEL SPAN OF 9 FEET SHALL BE PERMITTED FOR OPENING PROTECTION IN ONE- AND TWO-STORY BUILDINGS. PANELS SHALL BE PRECUT TO COVER GLAZED OPENINGS WITH ATTACHMENT HARDWARE PROVIDED. (REFER TO SECTION 1609.1.4, 1609.6.5 AND TABLE 1609.1.4 OF N.Y.S. RESIDENTIAL CONSTRUCTION CODE). THIS IS NOT A SUBSTITUTION FOR DESIGN -PRESSURE. ALL OPENINGS MUST HAVE DESIGN -PRESSURE UPGRADES WHERE APPLICABLE. ALL PANELS MUST BE CUT TO SIZE AND READY TO USE ON ANY NEW WINDOWS AND DOORS. SHUTTERS MUST BE MARKED FOR WHAT OPENING IT IS TO COVER. HARDWARE MUST ACCOMPANY SHUTTERS FOR INSTALLATION. CTN30-2 TW3046-2 (2) 1-3/4X9-1/2 M HDR. �� 3o"AFF (TYP.) / 1 1 ` 1 I 1 1 1 1 1 /1 1 1 1 , ` 1 1 \ / 1 1 1 1 1 1 i 1 1 I 1 1 , ol 1 1 / DN \ 1 1 1 1 , T_ = 1 1 = _ _ - 4A' ED' - - - - - -N - 1 CEILING - X b X / 1 1 N N _ N ♦ ` N 1 1 1 1 ♦ 1 1 � 1 1 ♦ 1 1 � 1 1 1 1 1 1 1 1 1 1 1 1 1 t 1 1 1 , 1 1 1 1 \ / 30"AFF (TYP.) (2)1-3/4X9-1/2 X9-1/2 M� HDR. CTN30-2 TW3046-2 24' -OI' 2ND. FLOOR PLAN SCALE: 1/4•• = 1'-0" 1/4" = 1'-011 EX. DOOR REPLACE EX. DOOR REPLACE EX. DOOR 24'-O" ST. FL LU O fV fV R PLAN 1/4" = 1'- cn z 0 H Q W J Q vo d e� a C.0 Z qct u7 w co Q N 00(o m = ti 0 a. 0 0 DRAWN BY: JF/MH June 05, 2011 SCALE: NTS SHEET NO: 77/ 1 M 1_ II _1 co ------------------------- 2) 1 3 X 1 7/8 ML w/ 1/2' STEEL FLITCH PLATE p s 10 ry �--- - -- ---- ------ Cl ---------- -----------� 1 R 1 I 1 1 1 I A N r 1 1 1 1 1 fV 1 1 1 I 1 1 1 1 1 I 1 1 1 1 1 1 1 1 1 1 1 1 1 1 ~ I 1 1 1 1 1 1 1 1 1 1 1 I 1 1 1 1 i I 1 1 1 I 1 1 1 - (2) 1-3/4X11-7/8 M L H D R. - V (2) 1-3/4X11-7/8 ML HDR. REPLACE EX. DOOR REPLACE EX. DOOR 24'-O" ST. FL LU O fV fV R PLAN 1/4" = 1'- cn z 0 H Q W J Q vo d e� a C.0 Z qct u7 w co Q N 00(o m = ti 0 a. 0 0 DRAWN BY: JF/MH June 05, 2011 SCALE: NTS SHEET NO: WIND LOAD PATH CONNECTION AND CONSTRUCTION DETAIL DRAWINGS USE THE FOLLOWING APPROVED USF' METAL CONNECTORS FOR PROPER WIND RESISTANT t GOOD CONSTRUCTION. FOLLOW MANUFACTURE'S RECOMMENDED INSTALLATION INSTRUCTIONS TO ACHIEVE MAXIMUM UPLIFT LOAD CAPACITY. KING STUDS • RAFTER WALL STUD ENDWALL CRIPPLE STUD o BOTTOM PLATE o RIDGE LEDGER BATHTUB cn HEADER DOUBLE JOIST Z SIDEWALL JACK STUDS RAFTER H FLOOR USP NUMBER DESCRIPTION APPLICATION x HOLD DOWN CONNECT TO 1 SIDE OF ALL CORNERS Q F4 1ST. ADS5 ANCHOR TO FOUNDATION W/ ANCHOR BOLTS CONNECT TO 1 SIDE OF ALL CORNERS ONBATH / SPA TUBS TO HAVE A DOUBLE FLOOR JOISTS UNDER FOR ADDED SUPPORT � . 1 a HOLD DOWN BOTH BOT. PLATE OF 2ND FLOOR AND TOP LOCATION USP NUMBER DESCRIPTION APPLICATION LOCATION USP NUMBER DESCRIPTION APPLICATION RAFTER SIZE USP NUMBER DESCRIPTION APPLICATION SUPPORT EACH WALL RUNNING PARALLEL WITH THE FLOOR 2ND. ADS5 ANCHOR PLATES OF 1ST. FLOOR. CONNECT THROUGH ALL OPENINGS LSTA12 1-1/4"x12" 20ga. STRAP APPLY TO EACH JACK STUD ROOF LSTA24 1-1/4"x24" 20ga. STRAP APPLY OVER RIDGE TO EACH RAFTER 2x6 -2x8 LS26 18ga. SLOPE HANGER APPLY TO EACH RAFTER /LEDGER JOIST DIRECTION WITH (2) JOISTS. UNDER WALL. THE FLOORS TO EACH OTHER W/ THREADED ROD. ALL OPENINGS RT3 OR RT7 TYDOWN ANCHOR APPLY TO EACH CRIPPLE STUD 2X10 LS210 118ga. SLOPE HANGER APPLY TO EACH RAFTER / LEDGER FOR JOIST NOT DIRECTLY UNDER PARALLEL WALLS, PROVIDE w A BLOCKING 024"OC ^ WALL STUD / ~ IOC THROUGH -ROOF EXHAUST' w VENTS SELECTED AND LOCATED BY CONTRACTOR O METAL STRAP CRICKET AT TOP -SIDE OF Z O VENTILATION CHANNEL O � RIM BOARD CHIMNEY RAFTER AS REQUIRED WALL SHEATHING RAFTERS SILL PLATE(S) � VENTILATION WOOD JOIST r --I SIDEWALL FLASHING BLOCKING ~ FOUNDATION � ', � ', � ', � ', � TOP PLATE BLOCK[NG O FINISH WALL AND MOISTURE 2x4 LEDGER STAPPING TO BE ATTACHED TO WALL STUDS 049"OC BARRIER TO LAP FLASHING 2x4 SOFFIT JOIST 0 AND ALL WINDOW/DOOR OPENING JACK STUDS AT WALL -- MAINTAIN GAP ATTIC SHALL BE PROVIDED WITH A FASCIA BETWEEN WALL FINISH AND MINIMUM NET FREE VENTILATING AREA FLOOR JOIST DEPTH USP NUMBER DESCRIPTION APPLICATION ROOFING TO AVOID SOAKING WALL STUD NOT LESS THAN 1/150 OF THE AREA OF GUTTER INSTALL 4'0" O.C. �,�� THE SPACE VENTILATED. ALL OPENINGS WOOD GIRDER 4"- 8" LSTA24 1-1/4"x24" 20ga. STRAP AND JACK STUDS SHALL BE COVERED WITH CORROSION- ONTIN. SCREENED VENT ON ALL OPENINGS PROVIDE HEMMED EDGE AT RESISTANT METAL MESH WITH MESH CONTIN. SOFFIT / EXT. PLYWOOD INSTALL 4'0" O.C. FLASHING TO FORM CHANNEL LOCATION USP NUMBER DESCRIPTION APPLICATION OPENINGS OF 4 INCH IN DIMENSION. v, OFFITED EAVE 811- 14#1 LSTA30 1-1/4"x30" 18ga. STRAP AND JACK STUDS �' AND SO AS TO MAINTAIN AIR CONNECT TO ON ALL OPENINGS71 GAP TO PREVENT CAPILLARY 4" - 6" RAFTER RT10 10-3/4" x 18ga. TYDOWN ANCHOR EACH RAFTER PROVIDE BLOCKING BETWEEN JOISTS THAT ARE SPICED AND INSTALL 4'0" O.C. ACTION 1411-16" LSTA36 1-1/4"x36" 18ga. STRAP AND JACK STUDS / 8w- 12" RAFTER RT20 21-1/8" x 20ga. TYDOWN ANCHOR CONNECT TO ROOF VENTILATIONOVER BEARING WALLS AND HEADERS EACH RAFTER ON ALL OPENINGS KEEP ROOFING NAILS OUT SOFFITED EAVE DETAIL 2ND. FLOOR WALL�, OF FLASHING ' ROOFING LAPS BASE lowFLASHING 4INCHES � \ BASE FLASHING WRAPS CORNERS, RAFTER \ RIDGE CAP OF SAME EXTENDS UNDER SHINGLES AT MATERIAL AS ROOFING SIDES 4 INCHES AND LAPS NAILED TO SHEATHING SHINGLES AT BASE MIN. 4 INCHES THROUGH VENT WOOD JOIST (� TOP PLATE LLGIRDER/HEADER 1 ST. FLOOR WALL STAPPING TO BE ATTACHED TO WALL STUDS 049"OC WOOD JOIST AND ALL WINDOW/DOOR OPENING JACK STUDS METAL FLASHING AT ALL EAVES, SIDEWALLS, WALL STUD — FLOOR JOIST DEPTH USP NUMBER DESCRIPTION APPLICATION AND RAKES -- PROVIDE HEMMED EDGES SO RAFTERS INSTALL 4'0" O.C. AS TO FORM DRAINAGE CHANNELS AND 4" - 8" LSTA36 1-1/4"x36" 18ga. STRAP AND JACK STUDS PREVENT CAPILLARY ACTION LOCATION USP NUMBER DESCRIPTION APPLICATION PRE -MANUFACTURED ON ALL OPENINGS CONNECT EACH RIDGE VENT FOLDS KEEP SHEATHING MIN. 1-1/2" ALL JOISTS CONNECTED TO A FLUSH HEADER TO BE SUPPORTED WITH INSTALL 4'0" O.C. RAFTER/PLATE RT15 TYDOWN ANCHOR RAFTER TO PLATE OVER RIDGE TO FROM PEAK TO ALLOW FREE THE PROPER STEEL CONNECTOR. 8"- 16" AIR PASSAGE MSTA48 1-1/4"x48" 16ga. STRAP AND JACK STUDS CONNECT OVER CONFORM TO SLOPE IF ABLE, SET FIR JOISTS APROX. 1/2" HIGHER THAN LVL HEADERS W ON ALL OPENINGS PLATE/WALL SPTH4 STUD PLATE ANCHOR PLATES TO EACH STUD OF ROOF TO ALLOW FOR SHRINKAGE. I REDUCE BUMP OUTS ui ��Z DBL. SILL PLATE ,J V ( � Z Lo SUBFLOOR TERMITE SHIELD J Z C_ - a) SILL GASKET �-- / 1 WOOD JOISTS W C N 1 J Lo NEOPRE 6 MfL TYP. CONC. FOUNDATION A \ CONC..POLY SLAB GASKET NE �, 1 2x6 /2x8 CONTINUOUS WOOD PLATE Q O O (� DAMPPROOF EXTERIOR v GRANULAR FILL 6MIL POLY ON EXTERIOR � � � � � , � � � _ , , � , �� � � Z ' � 1 BOLTED t0 STEEL BEAM WITH r v STEEL COLUMN 1 1/2 DIA. BOLTS +� 48 o.c. STAG, O `a - dr ° ROOF JACK �� �\ Cr) CONC. SLAB ` \ 11 11 STEEL BEAM O A COMPACT FILL�1 p �` 1 4" x 1/4" x 8" STEEL W ROOFING LAPS � TOP AND BOTTOM PLATE KEYWAY FOOTING p v a • FLASHING AT , WITH 1/2" x 6" ANCHOR BOLT �' '� c- CONC. FTG. a A6'a G O r ° , a ANCHOR BOLT CONNECTION USE WITH 3x3 SQUARE WASHERS SIDES AND TOP �, 1/2" GROUT (USP lBPS58 OR BP583) � 1 n \' 3" STEEL COLUMN DRAIN TILE t7 REINFORCING BAR FOUNDATION 5/8 DIA. ANCHOR BOLT , ANCHOR BOLT CONNECTION SUPPORTING MAXIMUM SPACING FLASHING LAPS - I i • l 10 KIPS SILL PLATE TO FOUNDATIONROOFING AT BOTTOM ' CRAWL SPACE OR FOUNDATION 1 STORY 72" OC TYPICAL BEAM DETAIL TYPICAL CONC. FOUNDATION. APPLY PILASTERSSILL PLATE TO FOUNDATION 2 STORIES 36" OC WHERE NEEDED FOR STRUCTURAL BRACING. MIN. 3" STEEL COLUMN ANCHORED TO 24"x24"x12" CONC. FTG. CRAWL SPACE OR FOUNDATION STEEL / BOTTOM BEARING WALL BOTTOM PLATE TO FOUNDATION 1-2 STORIES 57" OC SLAB -ON -GRADE ROOF JACKS t VENTS DETAIL Ir -- SUBFLOOR CONC. SLAB DOOR FRAME 6X6 10/10 WWM COMPACT FILL i DOaR E Q--- JOIST ^\X i USE 2x9 DRAWN BY: JF/MH FOR BLOCKOUT STEEL BEAM 4" SLAB rt - P.T. PLATE/ACE � �. SLOPE W/ 6X6 WMM 4' DR YEWAY—.-a . • NOTCH JOIST AND ADJUST HEIGHT June 05, 2011 1/2" AIR AT END AND ° 1 1/21 •- (WITH A NAILING PLATE IF NEEDED) DES OF WOOD . ,• , n ' ° ' ° ► ' • TO BE APROX. 1/2" OR HIGHER THAN STEEL BEAM TO ALLOW FOR SHRINKAGE SCALE: NTS GRADE a yt `� 1 / �� c - BEAMS ° ° a. . . . ,Q (PROVIDE STRAPPING TO KEEP JOISTS ALIGNED) 12" MIN. 'o c - ° c 6X6 W.W.M. '^ 4% L`'a A'� ° �� NOTCH BEAM FOR MUDSILL IF REQUIRED -- MAXIMUM D o , , a o �_ �- SUBFLOOR Ewy •'� � REINFORCING BAR - - . I REINFORCING BAR �- NOTCH EQUALS 1/4 DEPTH OF BEAM a . ° ^ 1 ° °� p ' , a a. p JOIST �'9 SHEET NO: DRAIN TILE I - „ -►I 12 a :. SHEET METAL / 30* FELT UNDER BEAM AT POINT — t� ` �. ° �. °ao OF CONTACT WITH CONCRETE OR CONC. BLOCK _ _ STEEL BEAM a 3.. TYPICAL CONC. MONOLITHIC FOUNDATION. REINFORCE WITH (2) #4 REINFORCING BARS THICKEN SLABS BENEATH BEARING WALLS AND COLUMNS. 'A ° A SHIMS TO LEVEL BEAM PLATE (BOLTE REINFORCE FOOTING WITH (2) 4 REINFORCING BARS. 3" MINIMUM BEARING SURFACE FOR WOOD BEAM GARAGE DOOR $LOCKOUT BEAM POCKET GENERAL NOTES WIND FRAMING NOTES NAIL 1). RIDGE -TO -RAFTER ASSEMBLY: 1-1/4" x 20 gauge strap shall be attached to each pair of rafters in accordance to table 3.4. SPACING SPACING When a collar tie is used in leu of a ridge strap, the number of 10d common nails required 8d AS PER TABLE 3.8 CONSTRUCTION NOTES: in each end of the collar tie need not exceed the tabulated number of 8d nails in the strap. 2). RAFTER -TO -WALL ASSEMBLY: 1). The information within this set of construction documents is related to basic design intent and framing details. They are intended as a construction aid , not a substitute Lateral framing and shear wall connections for rafter, ceiling or truss to top plate shall be in for generally accepted good building practice and compliance with current New York accordance to table 3.3. When a rafter or truss do not fall in line with studs below, rafters State building codes. The General Contractor is responsible for providing standard or trusses shall be attached to the wall top plate and the wall top plate shall be attached to construction details and procedures to ensure a professionally finished, structurally the to the wall stud with uplift connections. Roofs overhanging the rake side of the building sound and a weatherproof completed product. shall be connected with uplift connections in accordance with table 3.3c. 2). The General Contractor is responsible for ensuring that all work and construction 3). WALL-TO-WALL ASSEMBLY: meets current federal, state, county and local codes, ordinances and regulations, etc. Wall studs above and studs below a floor level shall be attached with uplift connections in These codes are to be considered as part of the specifications for this building and accordance with table 3.3b. When wall studs above do not fall in line with studs below, the should be adhered to even if in variance with the plan. studs shall be attached to a common member in the floor assembly with uplift connectors in WFCM - SBC accordance with table 3.3. 3). Dimensions shall take precedent over scaled drawings. CEILING JOIST LAPS (DO NOT SCALE DRAWINGS). 4). WALL ASSEMBLY TO FOUNDATION: FACE First wall studs shall be connected to the foundation, sill plate, or bottom plate with uplift 4). The designer has not been engaged for construction supervision and assumes no connectors. Steel straps shall have a minimum embedment of 7 inches in concrete responsibility for construction coordinating with these plans, nor responsibility for foundation and slab -on -grade, 15 inches in masonry block foundations, or lapped under construction means, methods, techniques, sequences, or procedures, or for safety the plate and nailed in accordance with table 3.3b. When steel straps are lapped under the precautions and programs in connection with the work. There are no warranties for a bottom plate, 3 inch square washes shall be used with the anchor bolts. Anchor bolt specific use expressed or implied in the use of these plans. spacing is to be spaced and sized in accordance to table 3.2a. In addition to spacing, NAIL anchor bolts are to be spaced between 6-12 inches from the end of a sill plate and all 5). Refer to the Window and Door schedule for exterior openings. corners. 6). The General Contractor is to ensure that masonry or prefabracted fireplaces meets 5). TYPE I EXTERIOR SHEARWALL CONNECTIONS: or exceeds manufacture's specifications and applicable codes. Type 1 exterior shear walls with a minimum of 7/16 inch wood structural panel on the exterior NAIL attached with 8d common nails at 6" o.c. at the panel edges and 12" o.c. in the field, and 7). The General Contractor is to consult with the owner for all built-in items 1/2 inch gypsum wallboard on the interior attached with 5d cooler nails at 7" o.c. at panel such as bookcases, shelving, pantry, closets, trims, etc. edges and 10" o.c. in the field shall be in accordance with the length requirements specified NAILING SCHEDULE in table 3.15a -b. 8). Wind load requirements shall be taken into account during construction. 6). TYPE 11 EXTERIOR SHEARWALL CONNECTIONS: Type II exterior shearwalls shall meet the requirements of table 3.15a -b times the appropriate FOUNDATION NOTES: 1). The General Contractor and Mason to review plans, elevations, details and notes to length adjustment factors in table 3.16. determine intended heights of finished floor(s) above typical grade. 7). INTERIOR SHEARWALL CONNECTIONS: 2). All footings to rest on undisturbed (virgin) soil. (MIN. SOIL STRENGTH AT 2000psi) Allowable sidewall lengths provided in table 3.14 shall be permitted to be increased when interior shearwalls are used. Sheathing and connections shall be in accordance with 3). Provide 1/2" expansion joint material between concrete slabs and abutting 2.4.4.2 and 2.2.4 respectively. concrete or masonry walls occuring in exterior or unheated interior areas. 8). CONNECTIONS AROUND EXTERIOR WALL OPENINGS: 4). Any new concrete walls being attached to existing concrete structure shall Header and/or girder connections shall be attached with uplift connections in accordance with table 3.5. Window sill plates shall be have steel connectors in accordance with table be installed with #4 re -bar, 18" long at 12" o.c.. Use approved epoxy for installation. 3.5. 5). Unless otherwise noted, all slabs on grade to be 3500 p.s.i.. Concrete to be RESCHECK poured on 4 inch thick sand or gravel fill with 6x6 wire mesh reinforcing. Interior slabs 9). CATHEDRAL CEILING ASSEMBLY: to be minimum 3-1/2 Inch thick. All fill to be compacted to 95% relative density with Where a ridge is to be used as a structural beam, the rafters shall either be notched and 6" maximum lifts (layers). anchored on top of the beam or slope connectors shall be attached to each rafter -to -ridge 6). Crawl spaces to be provided with a minimum 18"x24" access opening. Install one along the open ceiling part of the building. Connections to the ridge and wall shall be be attached with the above requirements. 8x16 cast iron foundation vent for every 150 sq. ft. of area. DECK AND COVERED PORCH NOTES: 7). Dampproof exterior of foundation with bituminous coating as per 1). Unless otherwise noted, all framing material to be #1 ACQ pressure treated lumber. N.Y.S. Residential Construction Code. A 6 -mil polyethylene film shall be applied over the below grade portion of exterior walls prior to backfilling. All fasteners, hangers and anchors to be galvinized or stainless steel. 8). Drainage as per town and N.Y.S. Residential Construction Code. 2). Girders for deck joists to be bolted to each post with washers and nuts. Girders on concrete piers shall be anchored with proper steel connectors anchored into 1/2 dia 7 long FRAMING NOTES concrete with a minimum x anchor bolt with washers and nuts. 3). posts supporting girders shall be anchored to a 12"x12"x12" thick concrete footing. 1). All framing techniques and methods as prescriptive design of current SBC High Wind Edition Wood Framing Construction Manual. Use a minimum 1/2" dia x 7" long anchor bolt with washers and nuts. Footings Shall be 3 ft. 2). Unless otherwise noted, all framing and structural wood material to be #2 + BTR. below grade. Porches with covered roofs shall have 12" dia, concrete piers for the girders. Douglas Fir. 4). Deck joists to have blocking at 8'0 o.c.. 3). Floors, walls, ceilings and rafters to be spaced at 16 inches o.c. unless noted 5). A minimum of 10 inch flashing shall be installed between the building and ledger. otherwise. Ledger to be fastened to building with 1/2" dia. bolts with washers and nuts 4). Unless otherwise noted, all bearing wall headers to be (2) 2x10 #2 + BTR. Doug. Fir. where needed. Bearing wall headers to have (2) jack studs and (2) full length studs on each side of all 6). Concrete piers shall be a minimum 6" above grade. openings. LVL headers to have (3) jack studs and (2) full length studs on each side of openings. Bearing wall window sills shall also have (2) window sill plates for 2x4 wall 7). All joists to be supported with hangers and anchors. Each Joist shall also be anchored openings between 4'1 and 6'0 and 2x6 wall openings between 511 and 89. Provide fire to girder(s). and blocking where applicable. 5). All flush beams/headers to be installed with heavy duty galvinized hangers and 8). Covered Roofs shall be assembled and anchored the same manner as a typical building. anchors where applicable to all connecting joists. PLUMBING NOTES 6). Double up floor joists under walls that run parallel to the floor joist and under bathtubs. 1). All water supply, drainage and venting to be installed as per N.Y.S. Residential Floors to have ceramic the installed shall be verified for proper load capacity unless noted Construction Code. on plans. 2). Verify septic system with the Engineer for Suffolk County Health Department approval. 7). Provide blocking/bridging in floor joists at 8'0 o.c.. Use solid blocking in floor joists under all bearing walls. 3). If wall studs, plates or joists are cut out during installation for any plumbing related work, provide adequate bracing and plates to protect and secure the structure. Verify with the 8). Provide insulation baffles at eave vents between rafters. Install draft blocking as state code and manufacture's recommendation for maximum hole size and spacing permitted. needed. HVAC SYSTEM NOTES 9). Unless otherwise rioted, all roofs and walls to have a minimum 1/2" thick, 4 -ply Fir CDX exterior sheathing grade plywood. Plywood to cover over plates and headers. 1). Mechanical subcontractor is responsible for adhearing to all applicable codes and safety requirements. 10). Unless otherwise noted use 3/4" thick T&G PTS Fir or Advantech plywood subfloor adhered with PL400 adhesive and screwed to floor joists. Finished floor to be installed 2). HVAC subcontractor is to fully coordinate all system data and requirements with the over subfloor as per manufactures instructions. equipment supplier. 11). All bathroom walls to have 1/2" thick moisture -resistant sheetrock. Garage walls and 3). HVAC subcontractor to provide final system layout drawing and submit it to the General Contractor and owner for final review and approval. ceilings and over furnace to have 5/8" thick type -x sheetrock. All other parts of building to have regular 1/2" sheetrock. All walls to be taped and finished. ELECTRICAL NOTES: 12). All roof with a pitch less than 4:12 shall be installed with an Ice & Water barrier or 1). All electrical to be installed as per N.Y.S. Residential Construction Code. approved equal. Flat roofs shall be applied with a Fiberglas base sheet with an EPDM torch down type material over. 2). All electrical work shall be approved by a qualified Underwriter. 13). All sill plates and wood in contact with concrete to be pressure treated. Sill plates to 3). Install Smoke detectors and Carbon Monoxide detectors throughout as per section R317 be installed with a foam sill gasket and cop-r-tex termite shield or approved equal. of N.Y.S. Residential Construction Code. NAILING SCHEDULE ROOF FRAMING.- JOINT RAMING: JOINT DESCRIPTION QTY NAIL NOTES SPACING SPACING SPACING 8d AS PER TABLE 3.8 RAFTER TO 8' WALL: 3-8d COMMON EACH FACE NAIL TOP PLATE 10' WALL: 4-8d COMMON RAFTER TOE -NAIL CEILING JOIST 8' WALL: 3-8d COMMON EACH FACE TO TOP PLATE 10' WALL: 4-8d COMMON JOIST TOE -NAIL CEILING JOIST TO AS PER TABLE 3.7 EACH FACE PARALLEL RAFTER WFCM - SBC LAP NAIL CEILING JOIST LAPS AS PER TABLE 3.7 EACH FACE OVER PARTITION WFCM -SBC LAP NAIL COLLAR TIE AS PER TABLE 3.4 EACH FACE TO RAFTER WFCM - SBC END NAIL BLOCKING 2 - 8d COMMON EACH TOE TO RAFTER SEE CONSTRUCTION ANDWIND PATH CONNECTION END NAIL RIM BOARD 2 -16d COMMON EACH END TO RAFTER NAILING SCHEDULE END NAIL WALL FRAMING: JOINT DESCRIPTION QTY NAIL NOTES SPACING SPACING SPACING 8d AS PER TABLE 3.8 TOP PLATE TO 2 -16d COMMON PER FACE NAIL TOP PLATE 6d COMMON FOOT SEE NOTE: 1 TOP PLATES AT 4 -16d COMMON JOINTS FACE INTERSECTIONS WALLBOARD EA. SIDE NAIL STUD TO 2 -16d COMMON 24" FACE STUD DECKS O.C. NAIL HEADER TO 16d COMMON 16" O.C. FACE HEADER 11 ALONG EDGES NAIL TOP OR BOTTOM 2 - 16d COMMON PER 2x4 STUD END PLATE TO STUD 3 -16d COMMON PER 2x6 STUD NAIL BOTTOM PLATE TO: PER FACE NAIL FLOOR JOIST, BAND JOIST, 2 -16d COMMON FOOT SEE NOTE: 1,2 END JOIST OR BLOCKING FLOOR FRAMING: JOINT DESCRIPTION QN NAIL NOTES SPACING SPACING SPACING 8d AS PER TABLE 3.8 JOIST TO: 4 - 8d COMMON PER TOE SILL, TOP PLATE OR GIRDER 6d COMMON JOIST NAIL BRIDGING 2 - 8d COMMON EACH TOE TO JOIST WALLBOARD END NAIL BLOCKING 2 - 8d COMMON EACH TOE TO JOIST DECKS END NAIL BLOCKING TO: 3 -16d COMMON EACH TOE SILL OR TOP PLATE 11 BLOCK NAIL LEDGER STRIP 3 - 16d COMMON EACH FACE TO BEAM 200 JOIST NAIL JOIST ON LEDGER 3 - ad COMMON PER TOE TO BEAM SEE CONSTRUCTION ANDWIND PATH CONNECTION JOIST NAIL BAND JOIST 3 -16d COMMON PER END TO JOIST NAILING SCHEDULE JOIST NAIL BAND JOIST TO: 2. 16d COMMONT PER TOE NAIL SILL OR TOP PLATE FOOT SEE NOTE: 1 ROOF SHFATHING- TRUSS DESIGN N/A - STANDARD STICK FRAME CONSTRUCTION JOINT DESCRIPTION NAIL QTY NAIL NOTES SPACING SPACING STRUCTURAL PANEL 8d AS PER TABLE 3.8 7" O.C. EDGE WFCM-SBC 8d COMMON CEILING SHEATHING: JOINT DESCRIPTION NAIL NAIL NOTES QTY. SPACING GYPSUM WALLBOARD 5d COOLERS 7" O.C. EDGE PANELS 8d COMMON 10 O.C. FIELD WALL SHEATHING: JOINT DESCRIPTION NAIL NAIL NOTES QTY. SPACING STRUCTURAL 8d COMMON AS PER TABLE 3.9 PANELS 8d COMMON WFCM-SBC 7/16" OSB 6d COMMON 3" O.C. EDGE PLYWOOD PRESCRIPTIVE AS PER N.Y.S. RESIDENTIAL CONSTRUCTION CODE AND 6 O.C. FIELD GYPSUM 5d COOLERS 711 O.C. EDGE WALLBOARD FRAMING ELEMENTS 10" O.0 . FIELD FLOOR SHEATHING: JOINT DESCRIPTION NAIL NAIL NOTES QTY. SPACING STRUCTURAL PANELS RESIDENTIAL DWELLING 6" O.C. EDGE 1" OR LESS 1 8d COMMON 1211 O.C. FIELD NOTES: THESE NOTES ARE ONLY TO BE REFERRED TO IF MENTIONED IN SCHEDULE NOTES ONLY. 1). Nailing requirements are based on wall sheathing nailed 6" on -center at the panel edge. If wall sheathing is nailed 3" on -center at the panel edge to obtain higher shear capacities, nailing requirements for structural members shall be doubled, or alternate connectors, such as shear plates, shall be used to maintain load path. 2). When wall sheathing is continuous over connected members,the tabulated number of nails shall be permitted to be reduced tot - 16d nail per foot. PLAN CONTENTS: OCCUPANCY CLASSIFICATION R3 RESIDENTIAL SEISMIC NOTES FROST AT PANEL EDGES BUILDING USE RESIDENTIAL DWELLING ICESHIELD BUILDING HEIGHT SNOW SPEED TOTAL SQ, FT, OF CONSTRUCTION WEATHERING LINE DESIGN CRITERIA PRESCRIPTIVE AS PER N.Y.S. RESIDENTIAL CONSTRUCTION CODE AND DESIGN CURRENT SBC NIGH WIND EDITION WOOD FRAME CONSTRUCTION MANUAL FLOOD HAZARDS LOAD (MPH) FRAMING ELEMENTS AS PER FLOOR PLANS CROSS SECTION AND GENERAL NOTES EXT. BALCONIES S0 REQUIRED DECKS 4,0 110 ATTICS w/o STORAGE 10 DESIGN LOAD CALCULATIONS (LIVE LOADS PSF) ATTICS w/ STORAGE ROOF (GROUND SNOW LOAD) ROOMS (OTHER THAN SLEEPING) 20 20 40 11 ROOMS (SLEEPING) 30 STAIRS 40 GAURDRAILS (ANY DIRECTION) 200 MODERATE EXPOSURE CATAGORY LOAD PATH SEE CONSTRUCTION ANDWIND PATH CONNECTION (ROOF - FOUNDATION) DETAIL PAGE 4 GENERAL NOTE PAGE NAILING SCHEDULE SEE GENERAL NOTE PAGE EGRESS SEE FLOOR PLANS AND WINDOW SCHEDULE FIRE PROTECTION (SMOKE 4 CO2 DETECTORS) SEE FLOOR PLANS TRUSS DESIGN N/A - STANDARD STICK FRAME CONSTRUCTION ENERGY CALCULATIONS RESCHECK CLIMATIC & GEOGRAPHIC DFSIC-2N C.RITFRIA GROUND WIND SEISMIC NOTES FROST AT PANEL EDGES SUPPORTS IN THE PANEL FIELD WINTER ICESHIELD 8d COMMON @ 6" O.C. SNOW SPEED DESIGN WEATHERING LINE TERMITE DECAY DESIGN UNDERLAYME14T FLOOD HAZARDS LOAD (MPH) CATEGORY SEE NOTES: 1,3 DEPTH TEMP. REQUIRED 20 LBS. 110 B SEVERE 3 FT. MODERATE SLIGHT TO 11 NONE TO HEAVY MODERATE ROOF SHEATHING REQUIREMENTS FOR WIND LOADS: SHEATHING LOCATION NAIL SPACING NAIL SPACING AT INTERMEDIATE NOTES AT PANEL EDGES SUPPORTS IN THE PANEL FIELD 4' PERIMETER EDGE ZONE 8d COMMON @ 6" O.C. 8d COMMON @ 6" O.C. SEE NOTES: 1,3 INTERIOR ZONE 8d COMMON @ 6" O.C. 8d COMMON @ 12" O.C. SEE NOTES: 1 ( BOTH FIELDS) INTERIOR ZONE 8d COMMON @ 6" O.C. 8d COMMON @ 12" O.C. NOTE: 2 FOR PANEL FIELD GABLE ENDWALL RAKE AND RAKE TRUSS 8d COMMON @ 4" O.C. 8d COMMON @ 4" O.C. SEE NOTES: 1,3 NOTES THESE NOTES ARE ONLY TO BE REFERRED TO IF MENTIONED IN SCHEDULE NOTES ONLY. 1). For roof sheathing within 4 feet of the perimeter edge of the roof, including 4 feet on each side of the roof peak, the 4 foot perimeter edge zone attachments required shall be used. 2). Tabulated 12 inch o.c. nail spacing assumes sheathing attached to rafter / truss framing members with G>0.49. For framing members with <0.42<G<0.49, the nail spacing shall be reduced to 6 inches o.c. 3). Tabulated 4 inch o.c. nail spacing assumes sheathing to rafter / truss framing members with G>0.49. For framing members with 0.42<G<0.49, the nail spacing shall be reduced to 3 inches o.c. WALL SHEATHING REQUIREMENTS FOR WIND LOADS: SHEATHING LOCATION NAIL SPACING NAIL SPACING AT INTERMEDIATE NOTES AT PANEL EDGES SUPPORTS IN THE PANEL FIELD 4' EDGE ZONE 8d COMMON @ 6" O.C. 8d COMMON @ 12" O.C. SEE NOTES: 1, 3 ( BOTH FIELDS) NOTE: 2 FOR PANEL FIELD INTERIOR ZONE 8d COMMON @ 6" O.C. 8d COMMON @ 12" O.C. I SEE NOTE: 3 NOTES THESE NOTES ARE ONLY TO BE REFERRED TO IF MENTIONED IN SCHEDULE NOTES ONLY. 1). For wall sheathing within 4 feet of the corners, the 4 foot edge zone attachment requirements shall be used. 2). Tabulated 12 inch o.c. nail spacing assumes sheathing attached to stud framing members with G>0.49. For framing members with 0.42<G<, the nail spacings shall be reduced to 6 inches o.c. 3). For exterior panel siding, galvinized box nails shall be permitted to be substituted for common nails. NOTE: CONTRACTOR TO PROVIDE SOIL TEST TO VERIFY EXISTING CONDITIONS. MINIMUM 3000# CAPACITY. 1). PROVIDE 5/8" TYPE -X SHEETROCK FIRE STOPPING AT 10'0 MAXIMUM DISTANCES FOR NON ACCESSIBLE AREAS. 2). USE SIMPSON HANGERS AND ANCHORS WITH Z -MAX TRIPPLE PROTECTIVE COATING FOR CONTACT WITH ACQ. 3). INSTALL 1 - Co2 DETECTOR IN ADDITION TO SMOKE ALARMS PER FLOOR. FIREBLOCKING REQUIRED Fireblocking shall be provided to cut off all concealed draft openings (both vertical and horizontal) and to form an effective fire barrier between stories, and between a top story and the roof space. Fireblocking shall be provided in wood -frame construction in the following locations. 1). In concealed spaces of stud walls and partitions, including furred spaces, at the ceiling and floor levels. Concealed horizontal furred spaces shall also be fireblocked at intervals not exceeding 10 feet. Batts or blankets of mineral or glass fiber shall be allowed as fireblocking in walls constructed using parallel rows of studs or staggered studs. 2). At all interconnections between concealed vertical and horizontal spaces such as occur at soffits, drop ceilings and cove ceilings. 3). In concealed spaces between stair stringers at the top and bottom of the run. Enclosed spaces under stairs shall comply with N.Y.S. Residential Code. 4). At openings around vents, pipes and ducts at ceiling and floor level, to resist the free passage of flame and products of combustion. 5). For the fireblocking of chimneys and fireplaces, refer to N.Y.S. Residential Code. Cf) Z 0 W a J w A Q A O CnO Z 0 0 o H Q (�. W W Z .� (D zU.) W (0pN J I Q 00(D Z _ ~ • O .H^ 0-O W O DRAWN BY: ]F/MH June 05, 2011 SCALE: NTS SHEET NO: IN