HomeMy WebLinkAbout39477-ZNo:
37505
Town of Southold
P.O. Box 1179
53095 Main Rd
Southold, New York 11971
CERTIFICATE OF OCCUPANCY
THIS CERTIFIES that the building ALTERATION
Location of Property: 820 Sigsbee Rd, Laurel
Date:
4/10/2015
4/10/2015
SCTM #: 473889 Sec/Block/Lot: 143.4-10
Subdivision: Filed Map No. Lot No.
conforms substantially to the Application for Building Permit heretofore filed in this office dated
12/29/2014 pursuant to which Building Permit No. 39477 dated 1/8/2015
was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for
which this certificate is issued is:
boiler and minor bathroom alteration as applied for.
The certificate is issued to Souravlis, Hrisovalantis & Ana
of the aforesaid building.
SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL
ELECTRICAL CERTIFICATE NO.
PLUMBERS CERTIFICATION DATED 1/1 ROM Is
39477
4/7/2015
Permit #: 39477
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
TOWN CLERK'S OFFICE
SOUTHOLD, NY
BUILDING PERMIT
(THIS PERMIT MUST BE KEPT ON THE PREMISES
WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS
UNTIL FULL COMPLETION OF THE WORK AUTHORIZED)
Permission is hereby granted to:
Souravlis, Hrisovalantis & Souravlis, Ana
21-36 38th St
Astoria. NY 11105
Date: 1/8/2015
To: Installation of a new boiler and minor bathroom alteration as applied for.
At premises located at:
820 Sigsbee Rd, Laurel
SCTM # 473889
Sec/Block/Lot # 143.-1-10
Pursuant to application dated 12/29/2014 and approved by the Building Inspector.
To expire on 7/9/2016.
Fees:
SINGLE FAMILY DWELLING - ADDITION OR ALTERATION $200.00
CO - ADDITION TO DWELLING $50.00
Form No. 6
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
TOWN HALL
765-1802
APPLICATION FOR CERTIFICATE OF OCCUPANCY
This application must be filled in by typewriter or ink and submitted to the Building Department with the following:
A. For new building or new use:
1. Final survey of property with accurate location of all buildings, property lines, streets, and unusual natural or
topographic features.
2. Final Approval from Health Dept. of water supply and sewerage -disposal (S-9 form).
3. Approval of electrical installation from Board of Fire Underwriters.
4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead.
5. Commercial building, industrial building, multiple residences and similar buildings and installations, a certificate
of Code Compliance from architect or engineer responsible for the building.
6. Submit Planning Board Approval of completed site plan requirements.
B. For existing buildings (prior to April 9, 1957) non -conforming uses, or buildings and "pre-existing" land uses:
1. Accurate survey of property showing all property lines, streets, building and unusual natural or topographic
features.
2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is
denied, the Building Inspector shall state the reasons therefor in writing to the applicant.
C. Fees
1. Certificate of Occupancy - New dwelling $50.00, Additions to dwelling $50.00, Alterations to dwelling $50.00,
Swimming pool $50.00, Accessory building $50.00, Additions to accessory building $50.00, Businesses $50.00.
2. Certificate of Occupancy on Pre-existing Building - $100.00
3. Copy of Certificate of Occupancy - $.25
4. Updated Certificate of Occupancy - $50.00
5. Temporary Certificate of Occupancy - Residential $15.00, Commercial $15.00
Date.
New Construction:
Location of Proper�
J
House No.
Old or Pre-existing Building:
Owner or Owners of Prope� P Sd v
Suffolk County Tax Map No 1000, Section
Subdivision
Permit No.
Date of Permit.
Health Dept. Approval:
Planning Board Approval:
Request for: Temporary Certificate
Fee Submitted: $
(check one)
to 12 of /Of
Street
s 4 /w So L)/ -.q ✓ 1.
Block
Filed Map.
Applicant:
Hamlet
Lot
Lot:
Underwriters Approval:
Final Certificate: (check one)
Applicant Signature
Town Hall Annex
54375 Main Road
P.O. Box 1179
Southold, NY 11971-0959
BUILDING DEPARTMENT
TOWN OF SOUTHOLD
Telephone (631) 765-1802
Fax (631) 765-9502
roger. riche rt(cD-town. so utho Id. ny. us
CERTIFICATE OF ELECTRICIAL COMPLIANCE
SITE LOCATION
Issued To: Hrisovalantis
Address: 820 Sigsbee Road City: Laurel St: New York Zip: 11948
Building Permit #: 39477 Section: 143 Block: 1 Lot: 10
WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE
Contractor: DBA: Hardy Plumbing License No:
Residential
Commerical
New
Addition
X
Indoor
Outdoor
Renovation
Survey
GAS
Duplec Recpt
SITE DETAILS
Office Use Only
X Basement
1st Floor
2nd Floor
Attic
INVENTORY
X Service Only
Pool
Hot Tub
Garage
Service 1 ph
Heat
GAS
Duplec Recpt
Ceiling Fixtures
HID Fixtures
Service 3 ph
Hot Water
GFCI Recpt
Wall Fixtures
Smoke Detectors
Main Panel
A/C Condenser
Single Recpt
Recessed Fixtures
CO Detectors
Sub Panel
A/C Blower
Range Recpt
Fluorescent Fixture
Pumps
Transformer
Appliances
Dryer Recpt
Emergency FixturesTime
Clocks
Disconnect
Switches
1
Twist Lock 171
Exit Fixtures
TVSS
El
Other Equipment:
Electrical Connections to New Gas Fumance to Include Power Supply and Controls
Notes:
Inspector Signature: Date: April 7, 2015
Electrical 81 Compliance Form.xls
CERTIFICATION
Date: 01-�?- \'S
Building Permit No. {acv m
Owner:
(Please print)
MAR 2 4 2015
6LDG.DEPT
TOn\- Or 0,001201-D
Plumber: Y r� YZ
(Please print)
I certify that tie solder used in the water supply system contains less than 2/10 of 1%
lead. A
E -
.� taw.
(Plumbers Signature)
Sworn to before me this
day of 1 '�C4�, 204�'-
Notary Public, County
EILEEN STRAND
NOTARY PUBLIC, State of New YON,
No.01ST6001493
auaimW in Suffolk COM EWW ja�ry 12,20./-0-
TOWN. OF SOUTHOLD BUILDING DEPT.
765-1802
INSPECTION
[ ]FOUNDATION 1ST [ ]ROUGH PLBG.
[ ]FOUNDATION 2ND [ ]IN ATION
[
FRAMING /STRAPPING INAL
[ ]FIREPLACE &CHIMNEY [ ]FIRE SAFETY INSPECTION
[ ]FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION
[ ]ELECTRICAL (ROUGH) [ ]ELECTRICAL (FINAL)
MC'\AAM9lE.
DATE ��� � INSPECTOR
pF SO(/T�OIo
cou
-OWN OF SOUTNOLD BUILDING DEPT.
765.1802
INSPECTION
[ ] FOUNDATION 1ST [ ] ROUGH PLEIG.
[ ] FOUNDATION 2ND [ ] INSULATION
[ ] FRAMING / STRAPPING [ ] FINAL
[ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION
[ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION
[ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL)
REMARKS:
DATE 4 .1� INSPECTOR
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
TOWN HALL
SOUTHOLD, NY 11971
TEL: (631) 765-1802
FAX: (631) 765-9502
SoutholdTown.NorthFork.net PERMIT NO.
Examined , 20
Approved '20
Disapproved a/c
20
g G 0 E
iF r)
1L_0
BLDG. DEPT.
_ TOWN OF SOUTHOLD
BUILDING PERMIT APPLICATION CHECKLIST
Do you have or need the following, before applying?
Board of Health
4 sets of Building Plans
Planning Board approval
Survey
Septic Form
N.Y.S.D.E.C.
Trustees
C.O. Application
Flood Permit
Single & Separate
Storm -Water Assessment Form
Contact:
Mail to:
Phone:
57-57
nsp cto 7 ( 1 3_),
APPLICATION FOR BUILDING PERMIT
DatebPcLOK7�ff ?V6 , 20J2/
INSTRUCTIONS
a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4
sets of plans, accurate plot plan to scale. Fee according to schedule.
b. Plot plan showing location of lot and of buildings on premises, relationship to adjoining premises or public streets or
areas, and waterways.
c. The work covered by this application may not be commenced before issuance of Building Permit.
d. Upon approval of this application, the Building Inspector will' issue a Building Permit to the applicant. Such a permit
shall be kept on the premises available for inspection throughout the work.
e. No building shall be occupied or used in whole or-iri'part, for"any purpose what so ever until the Building Inspector
issues a Certificate of Occupancy.
f. Every building permit shall expire if the work authorized -has not commenced within 12 months after the date of
issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the
property have been enacted in the interim, the Building Inspector may authorize, in writing, the extension of the permit for an
addition six months. Thereafter, a new permit shall be required.
APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the
Building Zone Ordinance of the Town of Southold, Suffolk County, New York, and other applicable Laws, Ordinances or
Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The
applicant agrees to comply with all applicable laws, ordinances, building code, housing c de, and regula 'ons, and to admit
authorized inspectors on premises and in building for necessary inspections.
.(Signature of applicant or name, if a corporation)
gao SrSs �'P �ol / �s /mac%
Plvll 9 S
(Mailing address of applicant)
State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder
,4 & ( " # I I S iv 17 4 -
• , -
Name of owner of premises t S <N9 I
(As on the fax roll or latest deed)
If applicant is a corporation, signature of duly authorized officer
(Name and title of corporate officer)
Builders License No.
Plumbers License No.
Electricians License No.
Other Trade's License No.
1. Location of land on which propose(
House Number treet
County Tax Map No. 1000
will be
'I Y L.Jck
r
Section Block
Hamlet
I
Lot /0
2
3.
H
Subdivision
Filed Map No.
Lot
State existing use and occupancy of premises and intended use and occupancy of proposed construction:
a. Existing use and occupancy
b. Intended use and occupancy
15 // /? L06,/ 30 r
Nature of work (check which applicable): New Building Addition,
Repair Removal Demolition Other Work
Estimated Cost �Q� d Fee
(To be paid on filing this application)
If dwelling, number of dwelling units Number of dwelling units on each floor
If garage, number of cars
Alteration
(Description)
6. If business, commercial or mixed occupancy, specify nature and extent of each type of use.
7
Dimensions of existing structures, if any: Front Rear_
Height Number of Stories.
Dimensions of same structure with alterations or additions: Front
Depth Height Number of Stories
Depth
Dimensions of entire new construction: Front Rear. Depth
Height Number of Stories
9. Size of lot: Front Rear Depth
Rear
10. Date of Purchase Name of Former Owner
11. Zone or use district in which premises are situated
12. Does proposed construction violate any zoning law, ordinance or regulation? YES NO
13. Will lot be re -graded? YES NO Will,excessfill be -removed from premises? YES NO
14. Names of Owner of premises. ,;.,a. Address.,,,::., .. ,.. Phone No.
Name of Architect ,'Address Phone No
Name of Contractor Address ; :: Phone No.
15 a. Is this property within 100'feet of'a tidal wetland ora freshwaterwetland? *YES NO
* IF YES, SOUTHOLD TOWN TRUSTEES & D.E.C. PERMITS°MAY BE REQUIRED.
b. Is this property:within 300 feet of a tidal wetland? * YES NO
* IF YES, D.E.C. PERMITS MAY BE REQUIRED.,
16. Provide survey, to scale, with accurate foundation plan and distances to property lines.
17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey.
18. Are there any covenants and restrictions with respect to this property? * YES NO
* IF YES, PROVIDE A COPY:
STATE OF NEW YORK)
SS:
COUNTY OF )
being duly sworn, deposes and says that (s)he is the applicant
(Name of individual signing contract) above named,
(S)He is the
(Contractor, Agent, Corporate Officer, etc.)
of said owner or owners, and is duly authorized to perform or have.performed the said work and to make and file this application;
that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be
performed in the manner set forth in the application filed therewith.
Sworn to before met '
day of
Notary Public . Notary Public, Statdot Now YOM Signature of Applicant
No. 01BU6185050
Qualified in Suffolk Countv
commission Expires April 14, `2JDJ
Scott A. Russell ��7
SUPERVISOR`S ��[ �� A\(GI]EI��1UE1��C'
={
SOUTinOL TOWN d-SOUT OL ,NEW ox 1179 Town of ,Southold
53095 Main Road - SOUTHOLD, NEW YORK 11971 �� Y
r1Ot 4(t P
CHAPTER 236 - STORIAWATER MANAGEMENT WORK SHEET
( TO BE COMPLETED BY THE APPLICANT)
DOES THIS PROJECT INVOLVE ANY OF THEF®I,IOwyNG:
(CHECK ALL THAT APPLY)
A. Clearing, grubbing, grading or stripping of land which affects more
than 5,000 square feet of ground surface.
B. Excavation or filling involving more than 200 cubic yards of material
within any parcel or any contiguous area.
/� C';+�, r,r�rinrni'inn rig clnn wuhir-h P'Ki^Pf'f� 1(J 'fPP1' vertical rise t0
100 feet of horizontal distance.
❑ [TD. Site preparation within 100 feet of wetlands, beach, bluff or coastal
I erosion hazard area.
j E. Site preparation within the one -hundred -year floodplain as depicted
on FIRM Map of any watercourse.
❑ Ej F. Installation of new or resurfaced impervious surfaces of 1,000 square
feet or more, unless prior approval of a Stormwater Management
Control Plan was received by the Town and the proposal includes
in-kind replacement. of .impervious. surfaces. _..._._.......
If you answered NO to all of the questions above, STOP! Complete the Applicant section below with your Name,
_ Signature, Contact Information, Date & County Tax Map Number! Chapter 236 does not apply to your project.
If you answered YES to one or more of the above, please submit Two copies of a Stormwater Management Control Plan
and a completed Check List Form to the Building Department with your Building Permit Application.
S.C.T.M. ": 1000 Date;
APPLICANT: (Property Owner, Design Professional, Agent, Contractor, Other) pistrict
Dec� �29 Zoic'
NAME
Section Block Lpi _
Contact Information
� Address / Location of Construction W
Y if 1 4
Bull_ JANII _ :, ": ,.
. °iT USE ONLY
Reviewed 13}.
n
- —
;puroved fer procc�sir:e Bi r (din Perfnit.
`:.:;giro! Plat; Noi Re €;iredd
Starr!;water vlara errient
4orr't waterI viar iye- Fit ens ` riro! Ian is Required.
rJt'VJ2ii d tor.. n;�:rieerui T)e;
i;ar r:'tc,rtt far Revier�.;
1234567890 BLOOMBERG LP 10:00:14 a,m. 03-23-2015
a, <o
Town I -W Annex 7 41 Telephone (631) 76S-1802
54375 Maio. Road�x (681} 7695
P.O. Sox 1179 NG! ._ roner richert - oR 0u 0 .nV.us
Southold, NY 119710959
"wllfll le -
BUILDING DEPARTMENT
TOWN OF SOUTIiOLD
APPLICATION FOR ELECTRICAL INSPECTION
REQUESTED BY:
Company Name:
Name:
License No.:
No.:
Date: ArC4 ?3 ?oi
JOBSITE INFORMATION: (*IndicAtes required information)
*Name: i 'S d vG 14i . r �d.L) ra �� S
*Address: 2 D S S &to A A u o C)
*Cross Street:et- e O h ,-e /v -
*Phone No.: G 4f 6 4/z/ 5 S� 5
Permit No.: 3 9 y 7 7
Tax -Map District: 9000 Section: / yam_ Block: l Lot: �Q^
*BRIEF DESCR
IPTION OF WORK (PleasePrint Clearly)
�t 4'rd 'ns -411p) q & N', ---ai D d R __fpWeCkr
as kPGI' 4ql 44"a 0 l°'�- Gn 1°C fire- Si h J
(Please Circle All That Apply)
*is Job ready for Inspection: �! NO. Rough In Final
*Do -you need a Temp Certificate: YES 1 NO
Temp Information (if needed)
*SerWw Size: 1 Phase 3Phase 100 150 200 300 350 400 Other
*New Service: Re -connect Underground Number of Meters Change of Service Overhead
Additional Information: PAYMENT DUE WITH APPLICATION
Town Hall Annex
�J!
Telephone (631) 765-1802
54375 Main Road
Fax (631) 765-9502
P.O. Box 1179
G l 4byI
Southold, NY 11971-0959
-�oeyCOU
a
BUILDING DEPARTMENT
TOWN OF SOUTHOLD
March 16, 2015
Hrisovalantis Souravlis
21-3638 th Street
Astoria, New York 11105
RE: 820 Sigsbee Road, Laurel TLU
TO WHOM IT MAY CONCERN: PC�
The Following Items (if Checked) Are Needed To Complete Your Certificate of Occupancy:
Application for Certificate of Occupancy. (Enclosed)
CLQ"
Electrical Underwriters Certificate.
A fee of $50.00.
Final Survey with Health Department Approval.
I
Plumber Solder , ertiflcate. (AII permits involving plumbing after 4/1/84)
Trustees Certificate of Compliance. (Town Trustees # 765-1892)
Final Planning Board Approval. (Planning # 765-1938)
Final Fire Inspection from Fire Marshall.
Final Landmark Preservation approval.
Final inspection by Building Dept.
Final Storm Water Runoff Approval from Town Engineer
BUILDING PERMIT: 39477-Z Boiler & Bathroom Alteration
ITU
O
yy v
if l �I
Series 2
Gas -Fired Water Boilers
• Installation • Maintenance
ispiler.. �_ .
1• Startup • parts
b--
,� _ ,,.,.� E�• may-( F14�
y
11 a p,ti� �TO
5-1SQ2
SrEC; i
�,LLO1�VfNC� I�1• " _ RFOUIF'ED
FOU1�1Da11Or.I-caCAC,
FOR pO�JREO r'LLltJiElilG
�' ROU11O1`I
3, ifdSULA ��F;,Ci1OiI IJIUSf
4. FINAL - CCR C-0. . ihlF.
�3E GOI�tF't_E ` F ' �4�Ati L F�1EE�
UC 1,ON � I lE CODES OF NiDN
ALL GOhISTR FOR
RECUlRE1v"�EI`1iS OF RESFOi�1�1t�LC
�- - t1O�ERRORS.
YORY., Sl „t L COI.ySiI;UCiIOt�
pESIGN ®R
ULwk-1
Q ®WARNING This manual must only be used by a qualified heating installer/service technician.
a Before installing, read all instructions, including this manual, and any related
supplements. Perform steps in the order given. Failure to comply could result in
severe. personal injury, death or substantial property damage.
Rk
Mobile Product
Library
Part Number 550-142-779/1112
2e Prepare boiler — vent clamper installation
ms are used on gas-fired boilers with vent installation
dampers as shipped from factory. Boiler will not operate
without vent damper installed. 1. Install vent damper horizontally or vertically as
AWARNING
Only vent dampers listed in the Replacement parts list
on page 58 are certified for use with CGa boilers. Any
other vent damper installed could cause severe personal
injury or death.
Damper blade
Spark -ignited pilot systems— Refer to vent manu-
facturer's instructions to install plug (shipped with
damper) in damper hole. For spark -ignited pilot
boilers only, install plug with no hole in vent damper
hole.
Minimum clearances
Provide a minimum of 6" between the vent damper and
any combustible material. (Provide a minimum of 36 "
between jacket top and combustible ceiling.)
Do not modify draft hood or vent damper, or make an-
other connection between draft hood and vent damper
or boiler except as noted below. This will void CSA
certification and will not be covered by Weil -McLain
warranty. Any changes will cause severe personal injury,
death or substantial property damage.
Figure 8 Vent damper assemblies
Effikal or Field Controls Johnson Controls damper
damper Refer to vent manufacturer's instructions to install
plug (shipped with damper) in damper hole.
Dampe
blade
indicat<
Hold -open switch (Effikal only) —
Install vent damper so that switch
is visible and accessible to user.
shown in vent damper manufacturers mstructions.
Vent damper must be installed so that it serves only
one boiler and so damper blade indicator is visible
to the user. See Figure 8. .
2. Screws or rivets used to secure the vent damper to
the draft hood must not interfere with rotation of
the damper blade.
3. Install damper harness between damper actuator
and knockout in jacket top panel. Use strain relief
connectors and locknuts to secure both ends of
damper harness.
A CAUTION Keep wiring harness clear of all hot
surfaces.
WARNING
LINE UP KEYWAY WHEN
CONNECTING PLUGS.
FORCING A MISMATCH
CAN CAUSE A
HAZARDOUS CONDITION.
®o
x m� ma
Keyway � Key 59304
4. Read and apply the harness plug warning label
(shown above) so that it is visible after installation.
5. Plug damper harness receptacle into damper harness
plug.
Bypassing oumpering) vent damper
will cause flue products such as
carbon monoxide to escape into
the house. This will cause severe
personal injury or death.
A----- ON After boiler has operated once, if ei-
CAUTther end of harness is disconnected,
the system safety shutdown will oc-
cur. The boiler will not operate until
harness is reconnected.
NOTICE Effikal or Field Controls damper—
Damper hold open switch must be
in Automatic Operation position
59325 for system to operate properly.
15
Part Number 550-142-779/1112
Coe Series 2 Gas -Fired Water MARer MONNerrun
11-M
2C Prepare are boiler draft hood, & spill switch
{
®raft hood installation
1. Orient draft hood with $pill switch mounting holes to front of boiler
as shown in Figure 7.
2. Secure draft hood to outlet at top of boiler with sheet metal screws.
3. Bottom of draft hood or "skirt" must have clearance dimension above
jacket top panel as indicated on draft hood.
Do not alter boiler draft hood or place any obstruction or
non -approved vent damper in breeching or vent system.
CSA certification will become void. Flue gas spillage and
carbon monoxide emissions will occur causing severe
personal injury or death.
Figure 6 Install spill switch
Spill switch
Draft hood -
Spill switch installation
1. Fasten spill switch to draft hood as shown in Figure 6
and Figure 7.
2. See Wiring diagram to connect wires%
a. Spark -ignited pilot boiler —
see pages 36 and 37
AWARNING Improper orientation of spill switch
may cause boiler to shut down. The
loss of heat can result in significant
damage due to freezing.
Figure 7 Spill switch with wire harness
Draft hoo
Spill swig
Spill swig
harness
Damper F
knockout
2dPrepare —install vent piping
1. Connect from draft hood or vent damper outlet to chimney or vent
with same size vent connector.
2. Where possible, vertical venting to the outside from the draft hood or
vent damper outlet will offer best performance.
3. Where horizontal vent connector is used, slope upward at least VV per
lineal foot toward chimney or vent and support with hangers to prevent
sagging.
4. Breeching must not be connected to any portion of a mechanical draft
system that can operate under positive pressure.
14 Part Number 550-142-779/1112
III
1 11
t'III I I III IIItIII
- p
Pre are boiler location — clearances
Recommended SERVICE clearances Figure 1b Required MINIMUM clearances
1. Provide clearances for cleaning and servicing the boiler and for
access to controls and components. See Figure la for recommen-
dations.
2. Provide at least screwdriver clearance to jacket front panel screws
for removal of front panel for inspection and minor service. If
unable to provide at least screwdriver clearance, install unions and
shutoff valves in system so boiler can be moved for servicing.
Figure 1 a
Recommended
service
clearances
(see WARNING
below)
WARN
Required MINIMUM clearances (Fig.1 b)
AWARNING Never install the boiler in a space with clear-
ances less than the minimum clearances shown
in Figure 1 b. Failure to comply can result in severe
personal injury, death or substantial property dam-
age and reduced boiler life.
1. Hot water pipes: at least 1/2 inch from combustible material.
2. Single-wall vent pipe. at least 6 inches from combustible mate-
rial.
3. Type B double-wall metal vent pipe: refer to vent manufacturer's
recommendation for clearances to combustible material.
Part Number 550-142-779/1112
Flooring
The CGa boiler is approved for installation on combustible
flooring, but must never be installed on carpeting.
AWARNING Do not installboiler on carpeting even
if foundation is used. Fire can result,
causing severe personal injury, death
or substantial .property damage.
Foundation
1. Provide a solid brick or minimum 2 -inch thick concrete
foundation pad if any of the following is true:
• floor can become flooded.
• the boiler mounting area is not level.
2. Minimum dimensions are 25" length by:
mum h founda lon w dtK
CGa-25/3 12" CGa-6
21"
' GGa �#
�A-4 ., � ,..
4 �
WON .
CGa-5 18" CGa-8
27"
Residential garage installations
Take the following special precautions when installing the
boiler in a residential garage. If the boiler is located in a
residential garage, per ANSI Z223.1:
• Mount the boiler a minimum of 18 inches above the
floor of the garage to assure the burner and ignition
devices will be no less than 18 inches above the floor.
• Locate or protect the boiler so it cannot be damaged
by a moving vehicle.
Bathroom Plumbing 820 Sigsbee Road Mattituck New York 11952
H.Vonde Souravlis
Proposal: installing secondary sink in bathroom. Extending the
waste lines installing new angle stops, valves escutcheons and
p -trap.
All work to be performed by
Hardy Plumbing, Heating & Air Conditioning
Mattituck New York 11952
H.Souravlis
A
C
Boiler installation
820 Sigsbee Road Mattituck New York 11952
All work to be performed by
Hardy Plumbing, Heating & Air Conditioning
Mattituck New York 11952
Installation of a weil me lain cga-6 (127,000 btu) natural gas
fired energy star rated high efficiency cast iron boiler with
one heating zone
Propose to supply and install a Taco 007 circulator, Taco 1"
flow valve, Taco pressure reducing valve,, Taco air vent, extrol
#30 expansion tank, watts backflow preventer, me donnell miller
low water cut off and any necessary pipe, valves and fittings
needed to connect to the existing 1" copper supply and return
heat line.
Propose to install 7" galvanized smoke pipe and connect to the
existing chimney (clean any debris from the chimney base, if
necessary).
Propose to install a 3/4" gas line and connect to the boiler and
the existing gas line.
Propose to pressure test the gas line to ensure there are no
leaks.
Propose to wire the boiler and check to ensure that is operating
properly and efficiently.
Removal and disposal of the existing boiler.
H.Souravlis