HomeMy WebLinkAbout39189-Z1tyar.._a.-=Gr
Fat Town of Southold 4/6/2015
P.O. Box 1179
53095 Main Rd
4 �♦ Southold, New York 11971
CERTIFICATE OF OCCUPANCY
No: 37492 Date: 4/3/2015
THIS CERTIFIES that the building RESIDENTIAL ALTERATION
Location of Property: 55 Skunk Ln, Cutchogue,
SCTM #: 473889 Sec/Block/Lot: 85.-3-2.1
Subdivision: Filed Map No.
conforms substantially to the Application for Building Permit heretofore
Lot No.
filed in this office dated
9/3/2014 pursuant to which Building Permit No. 39189 dated 9/16/2014
was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for
which this certificate is issued is:
ALTERATIONS TO AN EXISTING SINGLE FAMILY DWELLING AS APPLIED FOR
The certificate is issued to Skunk and Main LLC
(OWNER)
of the aforesaid building.
SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL
ELECTRICAL CERTIFICATE NO.
PLUMBERS CERTIFICATION DATED
39189
03-27-2015
A o ed ignature
TOWN OF SOUTHOLD
" gtlFFOL j 'A r
y`�aF BUILDING DEPARTMENT
TOWN CLERK'S OFFICE
'a
W. ' SOUTHOLD, NY
BUILDING PERMIT
(THIS PERMIT MUST BE KEPT ON THE PREMISES
WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS
UNTIL FULL COMPLETION OF THE WORK AUTHORIZED)
Permit #: 39189 Date: 9/16/2014
Permission is hereby granted to:
Skunk and Main LLC
1000 Bridge Ln
Cutchoaue. NY 11935
To: Alterations to an existing single family dwelling in an existing single family dwelling
with retail store building.
At premises located at:
55 Skunk Ln, Cutchogue
SCTM # 473889
Sec/Block/Lot # 85.-3-2.1
Pursuant to application dated
To expire on 3/17/2016.
Fees:
9/3/2014
and approved by the Building Inspector.
CO - COMMERCIAL
COMMERCIAL ADDITION/ALTERATION
$50.00
$730.00
Town Hall Annex
54375 Main Road
P.O. Box 1179
Southold, NY 11971-0959
0
BUILDING DEPARTMENT
TOWN OF SOUTHOLD
Telephone (631) 765-1802
Fax (631) 765-9502
roger. riche rt(ab-town.southoId. ny.us
CERTIFICATE OF ELECTRICIAL COMPI ION[`F
SITE LOCATION
Issued To: Skunk & Main LLC
Address: 55 Skunk Lane City: Cutchogue St: New York Zip: 11935
Building Permit #: 39189 Section: 85 Block: 3 Lot: 2.1
WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE
Contractor: DBA: Electric Tec. Inc License No: 4814 -ME
011 t Ur- 1 AIL,
Office Use Only
Residential X Indoor X Basement
Commerical Outdoor X 1st Floor
New Renovation 2nd Floor
Addition Survey Attic
INVENTORY
Service Only
Pool
X Hot Tub
X Garage
Service 1 ph
Heat
BUILDING DEPARTMENT
TOWN OF SOUTHOLD
Telephone (631) 765-1802
Fax (631) 765-9502
roger. riche rt(ab-town.southoId. ny.us
CERTIFICATE OF ELECTRICIAL COMPI ION[`F
SITE LOCATION
Issued To: Skunk & Main LLC
Address: 55 Skunk Lane City: Cutchogue St: New York Zip: 11935
Building Permit #: 39189 Section: 85 Block: 3 Lot: 2.1
WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE
Contractor: DBA: Electric Tec. Inc License No: 4814 -ME
011 t Ur- 1 AIL,
Office Use Only
Residential X Indoor X Basement
Commerical Outdoor X 1st Floor
New Renovation 2nd Floor
Addition Survey Attic
INVENTORY
Service Only
Pool
X Hot Tub
X Garage
Service 1 ph
Heat
Duplec Recpt
23
Ceiling Fixtures
5
HID Fixtures
Service 3 ph
Hot Water
GFCI Recpt
7
Wall Fixtures
5
Smoke Detectors
3
Main Panel
A/C Condenser
1
Single Recpt
Recessed Fixtures
5
CO Detectors
1
Sub Panel
60A
A/C Blower
1
Range Recpt
1-40)
Fluorescent Fixture
Pumps
Transformer
Appliances
DW
Dryer Recpt1-30
Emergency Fixture
Time Clocks
1
Disconnect
Switches
17
Twist Lock
Exit Fixtures 11
TVSS
Other Equipment:
2- Arc Fault Circuit Breakers, 1- Exhaust Fan
Notes:
C
Inspector Signature: µ - - Date: March 27, 2015
Electrical 81 Compliance Form.xls
Form No. 6
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
TOWN HALL
765-1802
APPLICATION FOR CERTIFICATE OF OCCUPANCY
This application must be filled in by typewriter or ink and submitted to the Building Department with the following:
A. For new building or new use:
1. Final survey of property with accurate location of all buildings, property lines, streets, and unusual natural or
topographic features.
2. Final Approval from Health Dept. of water supply and sewerage -disposal (S-9 form).
3. Approval of electrical installation from Board of Fire Underwriters.
4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead.
5. Commercial building, industrial building, multiple residences and similar buildings and installations, a certificate
of Code Compliance from architect or engineer responsible for the building.
6. Submit Planning Board Approval of completed site plan requirements.
B. For existing buildings (prior to April 9, 1957) non -conforming uses, or buildings and "pre-existing" land uses:
1. Accurate survey of property showing all property lines, streets, building and unusual natural or topographic
features.
2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is
denied, the Building Inspector shall state the reasons therefor in writing to the applicant.
C. Fees
1. Certificate of Occupancy - New dwelling $50.00, Additions to dwelling $50.00, Alterations to dwelling $50.00,
Swimming pool $50.00, Accessory building $50.00, Additions to accessory building $50.00, Businesses $50.00.
2. Certificate of Occupancy on Pre-existing Building - $100.00
3. Copy of Certificate of Occupancy - $.25
4. Updated Certificate of Occupancy - $50.00
5. Temporary Certificate of Occupancy - Residential $15.00, Commercial $15.00
New Construction:
Date. I _3 0 --2-0 ) �-
Old or Pre-existing Building: iC (check one)
Location of Property: 5-5- stun),- Ce 0 g j Q
House No. Street Hamle
Owner or Owners of Property: ,e,, e, �Q V 1 e e i i -e
Suffolk County Tax Map No 1000, Section Block 3 Lot 2
Subdivision
Permit No.
Health Dept. Approval:
Planning Board Approval:
Date of Permit.
Request for: Temporary Certificate
Fee Submitted: $
Filed Map.
Applicant:
Underwriters Approval:
Lot:
Final Certificate: (check one)
Applicant Signature
tall rc4- rho��,o uryo�
qn�L •
TOWN OF SOUTHOLD BUILDING DPT. b�
765-1802
INSPECTION
[ ] FOUNDATION 1 ST [ ] ROUGH PLUMBING
[ ] FOUNDATION 2ND [ ] INSULATION
[ ]
FRAMING/ STRAPPING [ ] FINAL
[ ] FIREPLACE A CHIMNEY [ ] FIRE SAFETY INSPECTION
[ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION
] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL)
[ CODE VIOLATION [ ] CAULKING
REMARKS:
� 4-A�-
�� �o�y�OF SObj�olo
���DUNiY
TOWN OF SOUTHOLD BUILDING DEPT.
765-1802
INSPECTION
[Z
DATION 1 ST [ ] ROUGH PLUMBING
DATION 2ND [ ] INSULATION
NG / STRAPPING [ ] FINAL
[ ] FIREPLACE A CHIMNEY [ ] FIRE SAFETY INSPECTION
[ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION
[ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL)
[ ] CODE VIOLATION [ ] CAULKING
REMARKS:
`7 _ ',
DATE Q '3� � INSPECTOR �j
OF SOUTyo�
UNf`hljq�
TOWN OF SOUTHOLD BUILDING DEPT.
765-1802
INSPECTION
[ ] FOUNDATION IST [ ] ROUGH PLUMBING
[ ] FOUNDATION 2ND [ ] INSULATION
[ ]
FRAMING/ STRAPPING [ ] FINAL
[ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION
[ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION
ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL)
[ ] DE VIOLATION [ ] CAULKING
REMARKS:
DATE -ILI/ INSPECTORS`
TOWN OF SOUTHOLD BUILDING DEPT.
765-1802
INSPECTION
[ ] FOUNDATION 1 ST
[ ] FOUNDATION 2ND
[ ]
FRAMING/ STRAPPING
[ ] FIREPLACE A CHIMNEY
[ ] FIRE RESISTANT CONSTRUCTION
[ ] ELECTRICAL (ROUGH)
[ ] CODE VIOLATION
REMARKS:
[ ) ROUGH PLUMBING
[ ) INSULATION
[ ] FINAL
[ ] FIRE SAFETY INSPECTION
I 1 Flee Rmsranr PENETRATION
�ELEC7RICAL (FINAL)
[ ]CAULKING
DATE 2� t � INSPECTORS ""7 ` u
37 % 8 pf SOUI'yo
N �
TOWN OF SOUTHOLD BUILDING DEPT.
765-1802
INSPECTION
[ ] FOUNDATION 1 ST [
[ ] FOUNDATION 2ND [
[ ]
FRAMING/ STRAPPING [
[ ] FIREPLACE & CHIMNEY [
[ ] FIRE RESISTANT CONSTRUCTION [
[ ] ELECTRICAL (ROUGH) [
[ ] CODE VIOLATION [
RFMARKc•
ROUGH MBING
] 1 CATION
FINAL
] FIRE SAFETY INSPECTION
] FIRE RESISTANT PENETRATION
] ELECTRICAL (FINAL)
] CAULKING
DATE �`� � u INSPECTO
JAMES J. DEERKOSKI P.E.
260Deer Drive
Mattituck, NY 11952
(631) 774 7355
Date: November 13, 2014
To: Town of Southold Building Dept
Re: Insulation Inspection
Skunk+ Main LLC
Skunk La.
Cutchogue, NY
Permit#39189
To Whom It May Concern:
This letter certifies that the insulation installed at the above mentioned property was done
properly and meets all state and local codes. Any questions feel free to call.
P.E.
FIELD INSPE 4N R.BPi
FOUNDATION (1ST)
FOUNDATION (2ND)
ROUGH FiNG &
PLUMBING
INSULATION PER N. Y.
STATE ENERGY CODE
FINAL
n
------
- -
- - -
------
-------
----- -----------
yh�� •
l'
yh�� •
l'
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
TOWN HALL
SOUTHOLD, NY 11971
TEL: (631) 765-1802
FAX: (631) 765-9502
SoutholdTown.NorthFork.net PERMIT NO.
BUILDING PERMIT APPLICATION CHECKLIST
Examined , 20
Approved 20 �1l
Disapproved a/c i —3 2014
Expiration , 20
Do you have or need the following, before applying?
Board of Health
4 sets of Building Plans
Planning Board approval
Survey
Check
Septic Form
N.Y.S.D.E.C.
Trustees
C.O. Application
Flood Permit
Single & Separate
Storm -Water Assessment Form
Mail to:
Phone:
APPLICATION FOR BUILDING PERMIT
Date ®T 3 a , 20 14 -
INSTRUCTIONS
a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4
sets of plans, accurate plot plan to scale. Fee according to schedule.
b. Plot plan showing location of lot and of buildings on premises, relationship to adjoining premises or public streets or
areas, and waterways.
c. The work covered by this application may not be commenced before issuance of Building Permit.
d. Upon approval of this application, the Building Inspector will issue a Building Permit to the applicant. Such a permit
shall be kept on the premises available for inspection throughout the work.
e. No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector
issues a Certificate of Occupancy.
f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of
issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the
property have been enacted in the interim, the Building Inspector may authorize, in writing, the extension of the permit for an
addition six months. Thereafter, a new permit shall be required.
APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the
Building Zone Ordinance of the Town of Southold, Suffolk County, New York, and other applicable Laws, Ordinances or
Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The
applicant agrees to comply with all applicable laws, ordinances, building code, housing code, and regulations, and to admit
authorized inspectors on premises and in building for necessary inspections. Ll
(2
(Signature of applicant or name, if a corporation)
t�e-�A, 63t-gbs- 1q4�
(Mailing address of applicant)
State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder
Name of owner of premises V,0.A�e r -,e- TC t' Cdv�Q
(As on the tax roll or latest deed)
If applicant is a corporation, signature of duly authorized officer
(Name and title of corporate officer)
Builders License No.
Plumbers License No. _
Electricians License No._
Other Trade's License No.
Location of land on which proposed work will be done:
55- SY-v.r-,k 2 C��c�� v P
House Number Street Hamlet
County Tax Map No. 1000 Section s Block Lot
•N.. N.. �c w t:+t..a
Subdivision Filed Map No. Lot
2. State existing use and occupancy of premises and intended use and occupancy of proposed construction:
a. Existing use and occupancy 1
b. Intended use and occupancy r\
3. Nature of work (check which applicable): New Building Addition Alteration
Repair Removal Demolition Other Work
4. Estimated Cost 2-0 , (-)oo
Fee
(Description)
(To be paid on filing this application)
5. If dwelling, number of dwelling units Number of dwelling units on each floor
If garage, number of cars
6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. i -o �-e s
7. Dimensions of existing structures, if any: Front
Height Number of Stories,
Rear
Dimensions of same structure with alterations or additions: Front
Depth Height Number of Stories
Depth
8. Dimensions of entire new construction: Front Rear Depth
Height Number of Stories
9. Size of lot: Front Rear Depth
10. Date of Purchase Name of Former Owner
11. Zone or use district in which premises are situated
Rear
12. Does proposed construction violate any zoning law, ordinance or regulation? YES NO�<
13. Will lot be re -graded? YES NO Will excess fill be removed from premises? YES NO
14. Names of Owner of premises k,-V�-u -,re Qe t cP �"ddress S S S y- (-Ac ,.Rhone No.
Name of Architect er`c,..ner - )Onr, CocAor\ Address l-lsS S, s�Mc.�,cRhoneNo -715c)
Name of Contractor�-NL-C%c- p c -.r, 3 Address �� Phone No. 631--76-7- o 7; 12
15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO
* IF YES, SOUTHOLD TOWN TRUSTEES & D.E.C. PERMITS MAYBE REQUIRED.
b. Is this property within 300 feet of a tidal wetland? * YES NO
* IF YES, D.E.C. PERMITS MAY BE REQUIRED.
16. Provide survey, to scale, with accurate foundation plan and distances to property lines.
17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey.
18. Are there any covenants and restrictions with respect to this property? * YES NO
* IF YES, PROVIDE A COPY.
STATE OF NEW YORK)
SS:
COUNTY OF )
f-\ \ C\(\ C- v \ rAC-,\ C being duly sworn, deposes and says that (s)he is the applicant
(Name of individual signing contract) above named,
(S)He is the A " Z -r-" fi
I.J(Contractor, Agent, Corporate Officer, etc.)
of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;
that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be
performed in the manner set forth in the application filed therewith.
re me thl
day of 20 /
Notary'*{Pl}jaFj�, *_ ft1eofN wYWk Signature o pp i
t riiuc f N& 01006200M
`• � Qr�YAii>r>�CoYoq
I
O SUFFQ
Scott A. Russell Y00
SUPERVISOR
SOUTHOLD TOWN HALL - P. O. Box 1179
53095 Main Road - SOUTHOLD, NEW YORK 11971
lot
65T0IKIM[WA IEIE,
MA\INAG 1EM1ENT
'own of Southold
CHAPTER 236 - STORMWATER MANAGEMENT.WORK SHEET
( TO BE COMPLETED BY THE APPLICANT)
I90ES THIS PROJECT INVOLVE ANY OF THE FOLLOWING:
(CHECK ALL THAT APPLY) !
A. Clearing, grubbing, grading or stripping of land which affects more
than 5,000 square feet of ground surface.
B. Excavation or filling involving more than 200 cubic yards -of material
within any parcel or any contiguous area.
C. Site preparation on slopes which exceed 10 feet vertical rise to
10.0 feet of horizontal distance.
D. Site preparation within 100 feet of wetlands, beach, bluff or coastal
erosion hazard area.
E. Site preparation within the -one-hundred-year floodplain as depicted
on FIRM Map of any watercourse.
F. Installation of new -or resurfaced impervious surfaces of 1,000 square -
feet or more, unless prior approval of a Stormwater Management ,
Control Plan was received by the Town and the proposal includes
in-kind replacement of impervious surfaces. _
If you answered NO to all of the questions above, STOP! Complete the Applicant section below with your Name,
Signature, Contact Information, Date & County Tax Map Number! Chapter 236 does not apply to your project.
If you answered YES to one or more of the above, please submit Two copies of a Stormwater Management Control Plan
and a completed Check List Form to the Building "Department with your Building Permit Application.
APPLICANT: (Property Owner, Design Professional, Agent, Contractor, Other)
NAME \C��2 ��- (N 4
� �_W''
Contactlnforrnatiort
Mkpl m Numbed
Property Address Location of Construction Work:
&_ 1 .. iir► ./rte►
FORM A SMCP - TOS MAY 2014
S.C_T.M. ": 1000 Date
District
1165 -Z'\ g -3 Q_Z o Of
Section Block Lot
****FOR BUILDING DEPARTI`IENT USE O,NIL
Reviewed By: 34 OJEW
Date — j
Approved for processing Building Permit.
_ _ Stormwater Management Control Plan Not Required.
❑Stormwater Management Control Plan is Required.
(Forward to Engineering Department for Review.)
Town Hall Annex
54375 Main Road
P.O. Box 1179
Southold, NY 11971-0959
Telephone (631) 7965-1802
roger.richerttown soutnoQd.ny.us
BUILDING DEPARTMENT
TOWN OF SOUTHOLD
APPLICATION FOR ELECTRICAL INSPECTION
REQUESTED BY: G � bcy 1� Date:
Company Name: E) 2C ` p_� fin. ,
Name: -
License No.:
Address:
' Phone No.:
JOBSITE INFORMATION: (*Indicates required information)
*Name:
"Address:
*Cross Street:
*Phone No.:
Permit No.:
Tax -Map District:
1000 . Section: Block:
*BRIEF DESCRIPTION OF WORK (Please Print Clearly)
(Please Circle Ail That Apply)
*Is job ready for inspection: ES NO
*Do- you need a Temp Certificate: YES /(NO
Lot:
..Rno plc )-F
=Rough
Final
Temp Information (If. needed)
*Service Size: 1 Phas 3Phase 100 150 200 300 350 400 Other
*New Service: Re -connect Underground Number of Meters Change of Service Overhead
Additional Information, PAYMENT DUE WITH APPLICATION
C)
82 -Request for Inspection Form
Town Hall Annex
54375 Main Road
P.O. Box 1179
Southold, NY 11971-0959
March 30, 2015
Skunk and Main LLC
1000 Bridge Lane
Cutchogue NY 11935
SO�jyo�
�y�OUNTY,�
BUILDING DEPARTMENT
TOWN OF SOUTHOLD
Re: 55 Skunk lane, Cutchogue
TO WHOM IT MAY CONCERN:
The Following Items (if Checked) Are Needed To Complete Your Certificate of Occupancy:
Application for Certificate of Occupancy. (Enclosed)
Electrical Underwriters Certificate.
A fee of $50.00.
Final Health Department Approval.
Plumbers Solder Certificate. (All permits involving plumbing after 4/1/84)
Trustees Certificate of Compliance. (Town Trustees # 795-1892)
Final Planning Board Approval. (Planning # 765-1938)
Final Fire Inspection from Fire Marshall.
Final Landmark Preservation approval.
Final inspection by Building Dept.
Final Storm Water Runoff Approval from Town Engineer
BUILDING PERMIT — 39189 - Alterations
Telephone (631) 765-1802
Fax (631) 765-9502
i1D STAINLESS SIZED
OR GAL
DR GALVANIZED
WOOD SCREWS W/
WASHERS 0 I G.C.
I1YOC
Luo DFD2--I
STUDS
M STAINLESS STEEL
OR GALVANIZED —
WOOD SCR[WS W/
WAS/ERs Dl lr cc
1(Y ARA RATED SHEATHING
—GIUDE PLYWOOD
(ALTERNATIVIVE:
1�
� I
WINDOW SILL
USP NUMBERI
DESCRIPTION
APPLICATION
1
i ii
i l ile
APPLY TO EACH JACK STUD
11
i1 lj'Ij1/
nnNi_
nn
L,
1
IfillI
II1 l i
I
I
I1YOC
Luo DFD2--I
STUDS
M STAINLESS STEEL
OR GALVANIZED —
WOOD SCR[WS W/
WAS/ERs Dl lr cc
1(Y ARA RATED SHEATHING
—GIUDE PLYWOOD
(ALTERNATIVIVE:
1�
� I
WINDOW SILL
USP NUMBERI
DESCRIPTION
APPLICATION
%LL OPENINGS
LSTA12
nHinn
I
I
APPLY TO EACH JACK STUD
kLL OIPENINGS
��
TG
nnNi_
nn
L,
1
i
� I
WINDOW SILL
MULTIPLE ILYW WR AS9EMPL74
2.2%4 OFR2 STUDS LON/ECTED
TOGETHER WITH STAINLESS STEEL
OR GALVDIm DOLTS W/ WASHERS
AND IMS • r -r 4.G
51r ARA PLYWDDD
SHEAT"M
D1STAINLESS
OW GALVANMQ
WOOD SCREWS W1
WASHERS. 1r ac
I--
VZ'
TED SHEATHING
GRADE PLYWOOD
(ALTERWATTME. 7116• U,S.D.)
VVIINILJ-CaVr\IVI_ L/LLUr\1..7 rr\V 1 L-%- 11VIV 1 %a IN VYLJIJLIFO I r\VV I vuxr,%L. r P►1YL.L.
AS PER TABLE 1609.1.4, N.Y.S. RES. CODE: ALTERNATIVE FOR OPENING PROTECTION (IF NOT USING IMPACT GLAZING)
WINDBORNE DEBIRIS PROTECTION FASTENING SCHEDULE FOR WOOD STRUCTURAL PANELS WOOD STRUCTURAL PANELS WITH A MINIMUM THICKNESS OF 7116"
AND MAXIMUM PANEL SPAN OF B FEET SHALL BE PERMITTED FOR OPENING PROTECTION IN ONE- AND TWO-STORY BUILDINGS. PANELS SHALL BE PRECUT TO
COVER GLAZED OPENINGS WITH ATTACHMENT HARDWARE PROVIDED. (REFER TO SECTION 1609.1.4, 1609.6.5 AND TABLE 160!.1.4 OF N.Y.S. RESIDENTIAL
CONSTRUCTION CODE). THIS IS NOT A SUBSTITUTION FOR DESIGN -PRESSURE. ALL OPENINGS MUST HAVE DESIGN -PRESSURE UPGRADES WHERE APPLICABLE.
ALL PANELS MUST BE CIT TO SIZE AND READY TO USE ON ANY NEW WINDOWS AND DOORS. SHUTTERS MUST BE MARKED FOR WHAT OPENING IT IS TO COVER.
HARDWARE MUST ACCOMPANY SHUTTERS FOR INSTALLATION.
KING STUDS
CRIPPLE STUD
HEADER
JACK STUDS
LOOATION
USP NUMBERI
DESCRIPTION
APPLICATION
%LL OPENINGS
LSTA12
nHinn
I
I
APPLY TO EACH JACK STUD
kLL OIPENINGS
��
TG
nnNi_
nn
L,
1
i
�I
RN
��
C.■�
��ril•�.J�■.
�i
MULTIPLE ILYW WR AS9EMPL74
2.2%4 OFR2 STUDS LON/ECTED
TOGETHER WITH STAINLESS STEEL
OR GALVDIm DOLTS W/ WASHERS
AND IMS • r -r 4.G
51r ARA PLYWDDD
SHEAT"M
D1STAINLESS
OW GALVANMQ
WOOD SCREWS W1
WASHERS. 1r ac
I--
VZ'
TED SHEATHING
GRADE PLYWOOD
(ALTERWATTME. 7116• U,S.D.)
VVIINILJ-CaVr\IVI_ L/LLUr\1..7 rr\V 1 L-%- 11VIV 1 %a IN VYLJIJLIFO I r\VV I vuxr,%L. r P►1YL.L.
AS PER TABLE 1609.1.4, N.Y.S. RES. CODE: ALTERNATIVE FOR OPENING PROTECTION (IF NOT USING IMPACT GLAZING)
WINDBORNE DEBIRIS PROTECTION FASTENING SCHEDULE FOR WOOD STRUCTURAL PANELS WOOD STRUCTURAL PANELS WITH A MINIMUM THICKNESS OF 7116"
AND MAXIMUM PANEL SPAN OF B FEET SHALL BE PERMITTED FOR OPENING PROTECTION IN ONE- AND TWO-STORY BUILDINGS. PANELS SHALL BE PRECUT TO
COVER GLAZED OPENINGS WITH ATTACHMENT HARDWARE PROVIDED. (REFER TO SECTION 1609.1.4, 1609.6.5 AND TABLE 160!.1.4 OF N.Y.S. RESIDENTIAL
CONSTRUCTION CODE). THIS IS NOT A SUBSTITUTION FOR DESIGN -PRESSURE. ALL OPENINGS MUST HAVE DESIGN -PRESSURE UPGRADES WHERE APPLICABLE.
ALL PANELS MUST BE CIT TO SIZE AND READY TO USE ON ANY NEW WINDOWS AND DOORS. SHUTTERS MUST BE MARKED FOR WHAT OPENING IT IS TO COVER.
HARDWARE MUST ACCOMPANY SHUTTERS FOR INSTALLATION.
KING STUDS
CRIPPLE STUD
HEADER
JACK STUDS
LOOATION
USP NUMBERI
DESCRIPTION
APPLICATION
%LL OPENINGS
LSTA12
1-1/4"x12" 20ga. STRAP
APPLY TO EACH JACK STUD
kLL OIPENINGS
RT30RRT71
TYDOWN ANCHOR
APPLY TO EACH CRIPPLE STUC
TRAP
PLUMBING SCHEMATIC
N.T.S.
TO APROVED
SEPTIC SYSTEM
OCCUPANCY OR
USE IS UNLAWFUL
WITHOUT CERTIFICATE
OF OCCUPANCY ,
O
m
O
O
O
N
CX14 CX14 CX14 CX14 1W2032
LIVING ROOM
II
II
cid tib 6�=� ,-►
KITCHEN
ALTERED
BEDROOIM
EX. HALL
O EX. BATH
E TW2632
1
1
1
E
1
1
1
1
1
1
---------------------------------------------------
2ND. FLOOR PLAN
SCALE: 1/4" = 11-011
EX. DECK
1
1
1
1
-----------------------------------------
1 1
E 1
1 ; 1
1 1
,OFFICE
E E
E G
1 I
1 1
1 1
J
EXISTING 1ST. FLOOR PLAN
SCALE: 1/4" = 11-011
1. REPLACE EXISTING WINDOWS ANDERSEN 400 SERIES, HIGH PERFOMANCE.
2. NEW KITCHEN TO BE INSTALLED.
3. EXISTING ROOMS TO BE RE -PAINTED. REPLACE DOORS AS REQUIRED.
4. INSTALL SMOKE AND CO DETECTORS PER CODE.
EX. ATTIC
LIGHT STORAGE ONLY
F
F
�v
.:
M C H
Design Services
www.mchdesicinservices.com
phone:
(631) 298-2250
e-mail:
michael@mchdesignservices.com
PLUw1BER CERTIFICATIC
-_)N LEAD CONTENT BEFO
F.RTIFICATE OF OCCUPA
COLDER USED IN WATE
SUPPLY SYSTEM CANN(
EXCEED 2/10 OF 1% LEA
PLUMBING
ALL PLUMBING WASTE
8, ATER Lii�iES NEED
TES`►14, 0 E F-1:0— E COVERTNGI
TAIN STORM WATER RUNOFF
RSUANT TO CHAPTER 236
THE TOWN CODE.
V)
C/1
W
V, z
Z
i�
H
[� W
LLJ
A
O A
x
W
O
C) C6
W
V
�—� z
F-'DDDi
r�
V J
W
DRAWN BY: MH
8/19/2014
SCALE: 1/4" = 11-011
SHEET NO:
J
IE
ICY
T
GENEfRAL NOTESWIND FRAMING NOTES
1). RIDGE -TO -RAFTER ASSEMBLY:
1-1/4" x 20 gauge strap shall be attached to each pair of rafters in accordance to table 3.4.
When a collar tie is used in leu of a ridge strap, the number of 10d common nails required
CONSTRUCTION NOTES: in each end of the collar tie need not exceed the tabulated number of 8d nails in the strap.
1). The information within this set of construction documents is related to basic design 2). RAFTER -TO -WALL ASSEMBLY:
intent and framing details. They are intended as a construction aid , not a substitute Lateral framing and shear wall connections for rafter, ceiling or truss to top plate shall be in
for generally accepted good building practice and compliance with current New York accordance to table 3.3. When a rafter or truss do not fall in line with studs below, rafters
State building codes. The General Contractor is responsible for providing standard or trusses shall be attached to the wall top plate and the wall top plate shall be attached to
construction details and procedures to ensure a professionally finished, structurally the to the wall stud with uplift connections. Roofs overhanging the rake side of the building
sound and a weatherproof completed product. shall be connected with uplift connections in accordance with table 3.3c.
2). The General Contractor is responsible for ensuring that all work and construction 3). WALL-TO-WALL ASSEMBLY:
meets current federal, state, county and local codes, ordinances and regulations, etc. Wall studs above and studs below a floor level shall be attached with uplift connections in
These codes are to be considered as part of the specifications for this building and accordance with table 3.3b. When wall studs above do not fall in line with studs below, the
should be adhered to even if in variance with the plan. studs shall be attached to a common member in the floor assembly with uplift connectors in
accordance with table 3.3.
3). Dimensions shall take precedent over scaled drawings.
(DO NOT SCALE DRAWINGS). 4). WALL ASSEMBLY TO FOUNDATION:
First wall studs shall be connected to the foundation, sill plate, or bottom plate with uplift
4). The designer has not been engaged for construction supervision and assumes no connectors. Steel straps shall have a minimum embedment of 7 inches in concrete
responsibility for construction coordinating with these plans, nor responsibility for foundation and slab -on -grade, 15 inches in masonry block foundations, or lapped under
construction means, methods, techniques, sequences, or procedures, or for safety the plate and nailed in accordance with table 3.3b. When steel straps are lapped under the
precautions and programs in connection with the work. There are no warranties for a bottom plate, 3 inch square washes shall be used with the anchor bolts. Anchor bolt
specific use expressed or implied in the use of these plans. spacing is to be spaced and sized in accordance to table 3.2a. In addition to spacing,
anchor bolts are to be spaced between 6-12 inches from the end of a sill plate and all
5). Refer to the Window and Door schedule for exterior openings. corners.
6). The Generall Contractor is to ensure that masonry or prefabracted fireplaces meets 5). TYPE I EXTERIOR SHEARWALL CONNECTIONS:
or exceeds manufacture's specifications and applicable codes. Type I exterior shear walls with a minimum of 7/16 inch wood structural panel on the exterior
attached with 8d common nails at 6" o.c. at the panel edges and 12" o.c. in the field, and
7). The Generall Contractor is to consult with the owner for all built-in items 1/2 inch gypsum wallboard on the interior attached with 5d cooler nails at 7" o.c. at panel
such as bookcases, shelving, pantry, closets, trims, etc. edges and 10" o.c. in the field shall be in accordance with the length requirements specified
in table 3.15a -b.
8). Wind load requirements shall be taken into account during construction.
6). TYPE II EXTERIOR SHEARWALL CONNECTIONS:
FOUNDATION NOTES: Type II exterior shearwalls shall meet the requirements of table 3.15a -b times the appropriate
1). The General' Contractor and Mason to review plans, elevations, details and notes to length adjustment factors in table 3.16.
determine intended heights of finished floor(s) above typical grade. 7). INTERIOR SHEARWALL CONNECTIONS:
Allowable sidewall lengths provided in table 3.14 shall be permitted to be increased when
2). All footings to rest on undisturbed (virgin) soil. (MIN. SOIL STRENGTH AT 2000psi) interior shearwalls are used. Sheathing and connections shall be in accordance with
3). Provide 1/2" expansion joint material between concrete slabs and abutting 2.4.4.2 and 2.2.4 respectively.
concrete or masonry walls occuring in exterior or unheated interior areas. 8). CONNECTIONS AROUND EXTERIOR WALL OPENINGS:
Header and/or girder connections shall be attached with uplift connections in accordance
4). Any new concrete walls being attached to existing concrete structure shall with table 3.5. Window sill plates shall be have steel connectors in accordance with table
be installed with #4 re -bar, 18" long at 12" o.c.. Use approved epoxy for installation. 3.5.
5). Unless otherwise noted, all slabs on grade to be 3500 p.s.i.. Concrete to be
poured on 4 inch thick sand or gravel fill with 6x6 wire mesh reinforcing. Interior slabs 9)• CATHEDRAL CEILING ASSEMBLY:
to be minimum 3-1/2 inch thick. All fill to be compacted to 95% relative density with Where a ridge is to be used as a structural beam, the rafters shall either be notched and
6" maximum lifts (layers). anchored on top of the beam or slope connectors shall be attached to each rafter -to -ridge
along the open ceiling part of the building. Connections to the ridge and wall shall be be
6). Crawl spaces to be provided with a minimum 18"x24" access opening. Install one attached with the above requirements.
8x16 cast iron foundation vent for every 150 sq. ft. of area.
DECK AND COVERED PORCH NOTES:
7). Dampproof exterior of foundation with bituminous coating as per
N.Y.S. Residential Construction Code. A 6 -mil polyethylene film shall be applied over 1). Unless otherwise noted, all framing material to be #1 ACQ pressure treated lumber.
the below grade portion of exterior walls prior to backfilling. All fasteners, hangers and anchors to be galvinized or stainless steel.
8). Drainage as per town and N.Y.S. Residential Construction Code. 2). Girders for deck joists to be bolted to each post with washers and nuts.
Girders on concrete piers shall be anchored with proper steel connectors anchored
FRAMING NOTES into concrete with a minimum 1/2" dia x 7" long anchor bolt with washers and nuts.
1). All framing techniques and methods as prescriptive design of current SBC High Wind 3). Posts supporting girders shall be anchored to a 12"x12"x12" thick concrete footing.
Edition Wood Framing Construction Manual. Use a minimum 1/2" dia x 7" long anchor bolt with washers and nuts. Footings Shall be 3 ft.
below grade. Porches with covered roofs shall have 12" dia. concrete piers for the girders.
2). Unless otherwise noted, all framing and structural wood material to be #2 +BTR.
Douglas Fir. 4). Deck joists to have blocking at 8'0 o.c..
3). Floors, walls, ceilings and rafters to be spaced at 16 inches o.c. unless noted 5). A minimum of 10 inch flashing shall be installed between the building and ledger.
otherwise. Ledger to be fastened to building with 1/2" dia. bolts with washers and nuts
4). Unless otherwise noted , all bearing wall headers to be (2) 2x10 #2 + BTR. Doug. Fir. where needed.
Bearing wall headers to have (2) jack studs and (2) full length studs on each side of all 6). Concrete piers shall be a minimum 6" above grade.
openings. LVL headers to have (3) jack studs and (2) full length studs on each side of
openings. Bearing wall window sills shall also have (2) window sill plates for 2x4 wall 7). All joists to be supported with hangers and anchors. Each Joist shall also be anchored
openings between 4'1 and 6'0 and 2x6 wall openings between 5'11 and 8'9. Provide fire to girder(s).
and blocking where applicable.
8). Covered Roofs shall be assembled and anchored the same manner as a typical building.
5). All flush beams/headers to be installed with heavy duty galvanized hangers and
anchors where applicable to all connecting joists. PLUMBING NOTES
6). Double up floor joists under walls that run parallel to the floor joist and under bathtubs. 1). All water supply, drainage and venting to be installed as per N.Y.S. Residential
Floors to have ceramic the installed shall be verified for proper load capacity unless noted Construction Code.
on plans.
2). Verify septic system with the Engineer for Suffolk County Health Department approval.
7). Provide blocking/bridging in floor joists at 8'0 o.c.. Use solid blocking in floor joists
under all bearing walls. 3). If wall studs, plates or joists are cut out during installation for any plumbing related work,
provide adequate bracing and plates to protect and secure the structure. Verify with the
8). Provide insulation baffles at eave vents between rafters. Install draft blocking as state code and manufacture's recommendation for maximum hole size and spacing permitted.
needed. HVAC SYSTEM NOTES
9). Unless otherwise noted, all roofs and walls to have a minimum 1/2" thick, 4 -ply Fir 1). Mechanical subcontractor is responsible for adhearing to all applicable codes and safety
CDX exterior sheathing grade plywood. Plywood to cover over plates and headers. requirements.
10). Unless otherwise noted use 3/4" thick T&G PTS Fir or Advantech plywood subfloor 2). HVAC subcontractor is to fully coordinate all system data and requirements with the
adhered with PIL400 adhesive and screwed to floor joists. Finished floor to be installed equipment supplier.
over subfloor as per manufacture's instructions.
11). All bathroom walls to have 1/2" thick moisture -resistant sheetrock. Garage walls and 3). HVAC subcontractor to provide final system layout drawing and submit it to the General
ceilings and over furnace to have 5/8" thick type -x sheetrock. All other parts of building Contractor and owner for final review and approval.
to have regular 1/2" sheetrock. All walls to be taped and finished. ELECTRICAL NOTES:
12). All roof with a pitch less than 4:12 shall be installed with an Ice & Water barrier or 1). All electrical to be installed as per N.Y.S. Residential Construction Code.
approved equal. Flat roofs shall be applied with a Fiberglas base sheet with an EPDM
torch down type material over. 2). All electrical work shall be approved by a qualified Underwriter.
13). All sill plates and wood in contact with concrete to be pressure treated. Sill plates to 3). Install Smoke detectors and Carbon Monoxide detectors throughout as per section R317
be installed with a foam sill gasket and cop-r-tex termite shield or approved equal. of N.Y.S. Residential Construction Code.
NAILING SCHEDULE
M01001 0 a :_kyl
JOINT DESCRIPTION
NAIL
QTY.
NAIL
SPACING
NOTES
RAFTER TO
8' WALL: 3-8dl COMMON
EACH
TOE -NAIL
TOP PLATE
10' WALL: 4-8d COMMON
RAFTER
SEE NOTE: 1
CEILING JOIST
8' WALL: 3-8d1 COMMON
EACH
TOE -NAIL
TO TOP PLATE
10' WALL: 4-8d COMMON
JOIST
NAIL
CEILING JOIST TO
AS PER TABLE 3.7
EACH
FACE
PARALLEL RAFTER
WFCM - SBC
LAP
NAIL
CEILING JOIST LAPS
AS PER TABLE 3.7
EACH
FACE
OVER PARTITION
WFCM - SBC
LAP
NAIL
COLLAR TIE
AS PER TABLE 3.4
EACH
FACE
TO RAFTER
WFCM - SBC
END
NAIL
BLOCKING
2 - 8d COMMON
EACH
TOE
TO RAFTER
2 -16d COMMON
END
NAIL
RIM BOARD
2 - 16d COMMON
EACH
END
TO RAFTER
TO JOIST
END
NAIL
WALL FRAMING:
JOINT DESCRIPTION
QTY
NAIL
SPACING
NOTES
TOP PLATE TO
2 -16d COMMON
PER
FACE NAIL
TOP PLATE
SILL, TOP PLATE OR GIRDER
FOOT
SEE NOTE: 1
TOP PLATES AT
4 - 16d COMMON
JOINTS
FACE
INTERSECTIONS
TO JOIST
EA. SIDE
NAIL
STUD TO
2 - 16d COMMON
24"
FACE
STUD
TO JOIST
O.C.
NAIL
HEADER TO
16d COMMON
16" O.C.
FACE
HEADER
SILL OR TOP PLATE
ALONG EDGES
NAIL
TOP OR BOTTOM
2 -16d COMMON
PER 2x4 STUD
END
PLATE TO STUD
3 - 16d COMMON
PER 2x6 STUD
NAIL
BOTTOM PLATE TO:
JOIST ON LEDGER
I
PER
FACE NAIL
FLOOR JOIST, BAND JOIST,
2 -16d COMMON
FOOT
SEE NOTE: 1,2
END JOIST OR BLOCKING
BAND JOIST
3 -16d COMMON
PER
FLOOR FRAMING:
JOINT DESCRIPTION
Qom.
NAIL
SPACING
NOTES
JOIST TO:
4 - 8d COMMON
PER
TOE
SILL, TOP PLATE OR GIRDER
6d COMMON
JOIST
NAIL
BRIDGING
2 - 8d COMMON
EACH
TOE
TO JOIST
WALLBOARD
END
NAIL
BLOCKING
2 - 8d COMMON
EACH
TOE
TO JOIST
ATTICS w/o STORAGE
END
NAIL
BLOCKING TO:
3 -16d COMMON
EACH
TOE
SILL OR TOP PLATE
(LIVE LOADS PSF)
BLOCK
NAIL
LEDGER STRIP
3 -16d COMMON
EACH
FACE
TO BEAM
40
JOIST
NAIL
JOIST ON LEDGER
3 - 8d COMMON
PER
TOE
TO BEAM
SEE CONSTRUCTION ANDWIND PATH CONNECTION
JOIST
NAIL
BAND JOIST
3 -16d COMMON
PER
END
TO JOIST
EGRESS
JOIST
NAIL
BAND JOIST TO:
2 -16d COMMON
PER
TOE NAIL
SILL OR TOP PLATE
I FOOT
SEE NOTE: 1
ROOF SHEATHING:
JOINT DESCRIPTION
Qom,
NAIL
SPACING
STRUCTURAL
STRUCTURAL PANEL
8d
AS PER TABLE 3.8
5d COOLERS
7"O.C. EDGE
WFCM-SBC
6d COMMON
CEILING SHEATHING:
JOINT DESCRIPTION
NAIL
NAIL
STRUCTURAL
QTY.
SPACING
GYPSUM
5d COOLERS
7"O.C. EDGE
WALLBOARD
6d COMMON
10" O.0 . FIELD
WALL SHEATHING:
JOINT DESCRIPTION
NAIL
QTY.
NAIL
SPACING
STRUCTURAL
8d COMMON
AS PER TABLE 3.9
PANELS
8d COMMON
WFCM -SBC
7/16" OSB
6d COMMON
3" O.C. EDGE
PLYWOOD
PRE5CRIPTIVE AS PER N.Y.S. RESIDENTIAL CONSTRUCTION CODE
6 O.C. FIELD
GYPSUM
5d COOLERS
7"O.C. EDGE
WALLBOARD
HAZARDS
10" O.0 . FIELD
FI OOR SHEATHING:
JOINT DESCRIPTION
NAIL
NAIL
BUILDING= USE
QTY.
SPACING
STRUCTURAL PANELS
8d COMMON
6"O.C. EDGE
1" OR LESS
SNOW
12"O.C. FIELD
NOTES:
THESE NOTES ARE ONLY TO BE REFERRED TO IF
MENTIONED IN SCHEDULE NOTES ONLY.
1). Nailing requirements are based on wall sheathing
nailed 6" on -center at the panel edge. If wall sheathing
is nailed 3" on -center at the panel edge to obtain higher
shear capacities, nailing requirements for structural
members shall be doubled, or alternate connectors,
such as shear plates, shall be used to maintain load path.
2). When wall sheathing is continuous over connected
members,the tabulated number of naills shall be permitted
to be reduced tot - 16d nail per foot.
PLAN CONTENTS:
OCCUPANCY CLASSIFICATION
WIND
SEISMIC
BUILDING= USE
FROST
8d COMMON @ 6" O.C.
BUILDING HEIGHT
WINTER
ICESHIELD
TOTAL SQ. FT. OF CONSTRUCTION
SNOW
SPEED
DESIGN CRITERIA
PRE5CRIPTIVE AS PER N.Y.S. RESIDENTIAL CONSTRUCTION CODE
AND
TERMITE
CURRENT SBC HIGH WIND EDITION WOOD FRAME CONSTRUCTION MANUAL
FRAMING ELEMENTS
AS PER FLOOR PLANS CROSS SECTION AND GENERAL NOTES
HAZARDS
EXT. BALCONIES
60
CATEGORY
DECKS
40
ATTICS w/o STORAGE
10
REQUIRED
ATTICS w/ STORAGE
20
DESIGN LOAD CALCULATIONS
ROOF (GROUND SNOW LOAD)
20
(LIVE LOADS PSF)
ROOMS (OTHER THAN SLEEPING)
40
11
ROOMS (SLEEPING)
30
STAIRS
40
GAURDRAILS (ANY DIRECTION)
200
EXPOSURE CATAGORY
LOAD PATH
SEE CONSTRUCTION ANDWIND PATH CONNECTION
(ROOF - FOUNDATION)
DETAIL PAGE t GENERAL NOTE PAGE
NAILING SCHEDULE
SEE GENERAL NOTE PAGE
EGRESS
SEE FLOOR PLANS AND WINDOW SCHEDULE
Sym..
FIRE PROTECTION
SEE FLOOR PLANS
(SMOKE t CO2 DETECTORS)
TRUSS DESIGN
N/A - STANDARD STICK FRAME CONSTRUCTION
ENERGY CALCULATIONS
I RESCHECK
CLIMATIC & GEOGRAPHIC DESIGN CRITERIA
GROUND
WIND
SEISMIC
NOTES
FROST
8d COMMON @ 6" O.C.
8d COMMON @ 6" O.C.
WINTER
ICESHIELD
FLOOD
SNOW
SPEED
DESIGN
WEATHERING
LINE
TERMITE
DECAY
DESIGN
UNDERLAYMENT
HAZARDS
LOAD
(MPH)
CATEGORY
DEPTH
TEMP.
REQUIRED
20 LBS.
110
B
SEVERE
3 FT.
MODERATE
SLIGHT TO
11
NONE
TO HEAVY
MODERATE
ROOF SHEATHING REQUIREMENTS FOR WIND LOADS:
SHEATHING LOCATION
NAIL SPACING
AT PANEL EDGES
NAIL SPACING AT INTERMEDIATE
SUPPORTS IN THE PANEL FIELD
NOTES
4' PERIMETER EDGE ZONE
8d COMMON @ 6" O.C.
8d COMMON @ 6" O.C.
SEE NOTES: 1,3
INTERIOR ZONE
8d COMMON @ 6" O.C.
8d COMMON @ 12" O.C.
SEE NOTES: 1 ( BOTH FIELDS)
NOTE: 2 FOR PANEL FIELD
GABLE ENDWALL RAKE AND RAKE TRUSS
18d COMMON @ 4" O.C.1
8d COMMON @ 4" O.C.
SEE NOTES: 1,3
NOTES
THESE NOTES ARE ONLY TO BE REFERRED TO IF MENTIONED IN SCHEDULE NOTES ONLY.
1). For roof sheathing within 4 feet of the perimeter edge of the roof, including 4 feet on each side of the roof peak,
the 4 foot perimeter edge zone attachments required shall be used.
2). Tabulated 12 inch o.c. nail spacing assumes sheathing attached to rafter / truss framing members with G>0.49.
For framing members with <0.42<G<0.49, the nail spacing shall be reduced to 6 inches o.c.
3). Tabulated 4 inch o.c. nail spacing assumes sheathing to rafter / truss framing members with G>0.49. For
framing members with 0.42<G<0.49, the nail spacing shall be reduced to 3 inches o.c.
WALL SHEATHING REQUIREMENTS FOR WIND LOADS:
SHEATHING LOCATION
NAIL SPACING
NAIL SPACING AT INTERMEDIATE
NOTES
AT PANEL EDGES
SUPPORTS IN THE PANEL FIELD
4' EDGE ZONE
8d COMMON @ 6" O.C.
8d COMMON @ 12" O.C.
SEE NOTES: 1, 3 ( BOTH FIELDS)
NOTE: 2 FOR PANEL FIELD
INTERIOR ZONE
8d COMMON @ 6" O.C.
8d COMMON @ 12" O.C.
SEE NOTE: 3
NOTES
THESE NOTES ARE ONLY TO BE REFERRED TO IF MENTIONED IN SCHEDULE NOTES ONLY.
1). For wall sheathing within 4 feet of the corners, the 4 foot edge zone attachment requirements shall
be used.
2). Tabulated 12 inch o.c. nail spacing assumes sheathing attached to stud framing members with
G>0.49. For framing members with 0.42<G<, the nail spacings shall be reduced to 6 inches o.c.
3). For exterior panel siding, galvinized box nails shall be permitted to be substituted for common nails.
NOTE:
CONTRACTOR TO PROVIDE SOIL TEST TO VERIFY
EXISTING CONDITIONS. MINIMUM 3000# CAPACITY.
1). PROVIDE 5/8" TYPE -X SHEETROCK FIRE STOPPING AT 10'0 MAXIMUM DISTANCES FOR NON ACCESSIBLE AREAS.
2). USE SIMPSON HANGERS AND ANCHORS WITH Z -MAX TRIPPLE PROTECTIVE COATING FOR CONTACT WITH ACQ.
3). INSTALL 1 - Co2 DETECTOR IN ADDITION TO SMOKE ALARMS PER FLOOR.
FIREBLOCKING REQUIRED
Fireblocking shall be provided to cut off all concealed draft openings (both vertical and horizontal)
and to form an effective fire barrier between stories, and between a top story and the roof space.
Fireblocking shall be provided in wood -frame construction in the following locations.
1). In concealed spaces of stud walls and partitions, including furred spaces, at the ceiling and floor
levels. Concealed horizontal furred spaces shall also be fireblocked at intervals not exceeding 10
feet. Batts or blankets of mineral or glass fiber shall be allowed as fireblocking in walls constructed
using parallel rows of studs or staggered studs.
2). At all interconnections between concealed vertical and horizontal spaces such as occur at soffits,
drop ceilings and cove ceilings.
3). In concealed spaces between stair stringers at the top and bottom of the run. Enclosed spaces
under stairs shall comply with N.Y.S. Residential Code.
4). At openings around vents, pipes and ducts at ceiling and floor level, to resist the free passage of
flame and products of combustion.
5). For the fireblocking of chimneys and fireplaces, refer to N.Y.S. Residential Code.
www.mchdesianservices.com
phone:
(631) 298-2250
e-mail:
michael@mchdesignservices.com
Z
O
IN
O A
a
Z
H
O
En
117;7e\TiT1►I3'MUM
8/17/2014
SCALE: 1/4" = V-0111
SHEET NO: