Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
34599-Z
x f Town of Southold 3/4/2015 P.O. Box 1179 53095 Main Rd ,i Southold, New York 11971 "T{�XR`rr CERTIFICATE OF OCCUPANCY No: 37452 Date: 3/4/2015 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 1000 WATER TERRACE SOUTHOLD, SCTM #: 473889 See/Block/Lot: 88.-6-1324 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 4/6/2009 pursuant to which Building Permit No. 34599 dated 4/9/2009 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: roof mounted solar panels on an existing one family dwelling as applied for. The certificate is issued to TIMOTHY 7 KILCOMMONS (OWNER) of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. PLUMBERS CERTIFICATION DATED 10253 05-08-2009 52 Authorized Signature FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 34599 Z Date APRIL 9, 2009 Permission is hereby granted to: TIMOTHY J KILCOMMONS 1000 WATER TERRACE SOUTHOLD,NY 11971 for INSTALLATION OF SOLAR PANELS TO ROOF OF EXISTING SFD PER MANUFACTURE'S SPECS AS APPLIED FOR. at premises located at 1000 WATER TERRACE SOUTHOLD County Tax Map No. 473889 Section 088 Block 0006 Lot No. 013.024 pursuant to application dated APRIL 6, 2009 and approved by the Building Inspector to expire on OCTOBER 9, 2010. Fee $ 200.00 v� Authorized Signature ORIGINAL Rev. 5/8/02 Form No. 6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings, property lines, streets, and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage -disposal (S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead. 5. Commercial building, industrial building, multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings (prior to April 9, 1957) non -conforming uses, or buildings and "pre-existing" land uses: 1. Accurate survey of property showing all property lines, streets, building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied, the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy - New dwelling $50.00, Additions to dwelling $50.00, Alterations to dwelling $50.00, Swimming pool $50.00, Accessory building $50.00, Additions to accessory building $50.00, Businesses $50.00. 2. Certificate of Occupancy on Pre-existing Building - $100.00 3. Copy of Certificate of Occupancy - $.25 4. Updated Certificate of Occupancy - $50.00 5. Temporary Certificate of Occupancy - Residential $15.00, Commercial $15.00 Date. 2123 S New Construction: Old 0/1oLr Pre-existing Building: (check one) Property: Location of Pro a �� G rd-t7t'+� f rr�i CQ �'��� �` House No. Street Hamlet Owner or Owners of Property:A4kl�C�i^^,N'��-S Suffolk County Tax Map No 1000, Section Block �� Lot n/ S, 0 Z4 Subdivision Filed Map. 473 S 1 Lot: Permit No. Date of Permit. / .� ` Applicant: i Health Dept. Approval: Underwriters Approval: Planning Board Approval: / Request for: Temporary Certificate Final Certificate: (check one) Fee Submitted: $ /IVA; lv9 ApplicarA Slignature 40 Nottingham Drive, Middle Island, NY 11953 Vt Telephone: 631 495 8136 • Fax: 631 980 6455 • E-Mail: SBEIGS@gmail.com- OI D I CERTIFICATE OF ELECTRICAL COMPLIANCE Applicant: GO SOLAR Inc. Certificate No.: 10253 Rough In Inspection Date: May 2 ,2009 Final Inspection Date: May 2 ,2009 Application No.: 10253 Building Permit No.: Suffolk County Tax Map No.: This Certificate of Electrical Compliance is limited to the inspection and compliance of electrical equipment and/or work described below, installed by the applicant named above, located at the premise of and not after the final inspection date above: Owner: Tim Kilcommons Site Location: 1000 Water Terrace, Southold, NY 11971 Owner's Address (if different): Residential Indoor Basement Service Shed Commercial Outdoor First Floor- Pool _ :Hottub New Renovation Second Floor Attic _ _ Garage Addition Survey Other: Photo Voltaic System INVENTORY Single Phase Heat Duplex Recpt Ceiling Fixture HID Fixtures Three Phase Hot Water GFCI Recpt Wall Fixture Smoke Main Panel AC Cond Single Recpt Recessed Fixture CO Detect Sub Panel 8ckt AC Blower Range Recpt Flourescent Pumps Transformer Appliances Dryer Recpt Emergency Time Clock Disconnect 1 Switches Twist Lock Exit Fixtures TVSS GFCI Breaker Heat Pump Electric Heat Pool Luminaire Exhaust Fan Other Equipment: 8,775 watt system comprised of 39 SunPower 225 panels and 2 SunPower Fronius 4000 inverters The electrical work and/or equipment described above were inspected and appear to be in compliance with local, state and national electrical code requirements and this office. Applicant: GO SOLAR Inc. License NO.: 35972 -ME Inspected By: Gene Surdi Date Of Certificate: May 08, 2009 Signature: '�� ho,*pF SOUj,�o� TOWN OF SOUTNOLD BUILDING DEPT. 765-1802 INSPECTION [ ]FOUNDATION 1ST [ ]ROUGH PLBG. [ ]FOUNDATION 2ND [ ]INSULATION [ ]FRAMING /STRAPPING [� FINAL [ ] FlREPLACE 4 CHIMNEY [ ]FIRE SAFETY INSPECTION C 1 FIRE RESISTANT coHsrnuenoN [ ] FIRE RESIsrarrr vENETxana+ REM RKS: ME SEE, I'M � I \ r DATE � 9 INSPECTOR 3*,5/ 1 ->,� TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION ] FOUNDATION IST ] FOUNDATION 2ND ] FRAMING / STRAPPING ] FIREPLACE A CHIMNEY ] FIRE RESISTANT CONSTRIJCI REMARKS: DATE [ ] ROUGH PLBG. [ ] INS ON [ INAL [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT PENETRATION INSPECTOR ril March 24, 2010 Town of Southold Building Department 54375 Route 25 PO Box 1179 Southold, NY 11971 272 Main Road Riverhead, NY 11901 Phone(631)727-2224 Fax (631) 779-3344 Email infongosolar.com Website: www.gosolar.com D) IE CL �-- MAR5 z 2010 TOWNDEPT. TOWN OF SOUTHOLD Re: Building Permit for solar modules - Tim Kilcommons of 1000 Water Terrace in Southold, NY To Whom It May Concern: This is to certify that Go Solar, Inc. has installed Tim Kilcommons' 8,775 watt solar electric system to New York State building codes and to the manufacturer's specifications.. If you have further questions, please don't hesitate to contact either me at the above address and phone number. Thanks! Sincerely, Jeanne Smith Go Solar, Inc. NO�N'ui�IC� Sworn tome this QUALOW M SUFFOLK COMP Day of z/ i �; l U H& OIVE61 M37 OIIIr dw" 1 01/25011i ( Public) ............................ "Improving Our Planet One Roof At A Time" FIELD INSPECTION REPORT I DATE COMMENTS FOUNDATION (IST) �' y ------------------------------------- FOUNDATIpN (2ND) ROUGH FRAMING & PLUMBING C� c INSULATION PER N. Y. STATE ENERGY CODE x FINAL U `a- 0 el "IbDITIONAL COMMENTS 0 z m 1� y Z x y x C tr! H TOWN,OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following, before applying? TOWN HALL SOUTHOLD, NY 11971 TEL: (631) 765-1802 FAX: (631) 765-9502 v SoutholdTown.NorthFork.net PERMIT NO. Examined t 20 Ga Approved L� 20 Disapproved a/c Expiration , 20 Building Inspector Board of Health 4 sets of Building Plans_ Planning Board approval Survey Check Septic Form N.Y.S.D.E.C. Trustees Flood Permit Storm -Water Assessment Form Contact: f/ Mail to: _ IfMOAV 0 (Commons 000 ,0a�r I rf , So Phone: 76s- /69 S APPLICATION FOR BUILDING PERMIT INSTRUCTIONS Date 31 Ma(C� , 20 O9 a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans, accurate plot plan to scale. Fee according to schedule. b. Plot plan showing location of lot and of buildings on premises, relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application, the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e. No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim, the Building Inspector may authorize, in writing, the extension of the permit for an addition six months. Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County, New York, and other applicable Laws, Ordinances or Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances, building code, housing code, and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. /..... X�, //,�/ - - -- (SignqWe of applicant or name, if a corporation) 10 0ayer Trace it46i�/VZ 11M (Mailing address o applicant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder Name of owner of premises hi (As on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer (Name and title of corporate officer) Builders License No. Plumbers License No. Electricians License No. Other Trade's License No. 1. Location of land on which proposed work will be done: Iwo Water Ie'race sa,41ioip House Number Street Hamlet County Tax Map No. 1000 Section Subdivision 8800 Blo6k �' i ,� Lot Filed Map No. Lot 13024 2. State existing use and occupancy of premises and intended a. Existing use and occupancy Sires fAtnity drii b. Intended use and occupancy Sa✓m4 occupancy of proposed construction: .4 3. Nature of work (check which applicable): New Building Addition Alteration Repair Removal Demolition Other Work Jas it LkmJ,\ifd JN(Soi S o (Description) 4. Estimated Cost k Fee) (To be paid on filing this, application) 5. If dwelling, number of dwelling units N Number of dwelling units on each floor If garage, number of cars Nita 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. n /A -T 7. Dimensions pf existing structures, if any: Front —33 Rear 33j Depth 2-$'4 Height 430'y t,, d Number of Stories Z Dimensions of same structure with alterations or additions: Front NO C��" Rear +J 1\ Depth N h Height Number of Storie A 8. Dimensions of entire new construction: Front J �� Rear tj Its Depth /A Height N Number of Stories (J/p 9. Size of lot: Front 7.94= Rear I70,S Depth a3 10. Date of Purchase i �_.2= Name of Former Owner lcu1em�r i 11. Zone or use district in which premises are situated lie s>cfa t ,��iw1 12. Does proposed construction violate any zoning law, ordinance or regulation? YES NO 13 14 Will lot be re -graded? YES NO_�,/ Will excess fill be removed from premises? YES_ �(AY i cuyn')n5 Names of Owner of premises I I w3i I 11mCHDA 04u Address l U I0aier Tf v ncc Phone No Name of Architect Address Phone No Name of Contractor Go Soar Address Phone No. 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO * IF YES, SOUTHOLD TOWN TRUSTEES & D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey, to scale, with accurate foundation plan and distances to property lines. NO �,% 762165 -1695 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. 18. Are there any covenants and restrictions with respect to this property? * YES NO * IF YES, PROVIDE A COPY. STATE OF NEW YORK) SS: COUNTY OF,$ - being duly sworn, deposes and says that (s)he is the applicant (Name of individual signing contract) above named, (S)He is the N /A (Contractor, Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief, and that the work will be performed in the manner set forth in the application filed therewith. Sworn to,before me this T1`1 day of A pk l 20, ONNOLLY Notary Public Notary Public, tate of New York gnature of Applicant No. 52-59523 5, Suffolk County Commission Expires August 31. 2040 Town Hall Annex 54375 Main Road P.O. Box 1179 Southold, New York 11971-0959 February 9, 2010 BUILDING DEPARTMENT TOWN OF SOUTHOLD Telephone (631) 765-1802 Fax (631) 765-9502 Timothy Kilcommons 1000 Water Terrace Southold, NY 11971 N ertificatio rom an architect or engineer req o stening of e s of as y the Building Ins ct 1/19/10. TO WHOM IT MAY CONCERN: The following items are needed to complete your Certificate of Occupancy: .N, Application for Certificate of Occupancy. (Enclosed) \� Electrical Underwriters Certificate. A fee of $25.00. Final Health Department approval. Plumbers solder certificate (all permits involving plumbing after 4/1/84.) Trustees Certificate of Compliance. Final Planning Board Approval. Final Fire Inspection from Fire Marshal. Final inspection from the Building Department. Final Landmark Preservation approval. Building Permit: 34599-Z solar panels Town Hall Annex 54375 Main Road P.O. Box 1179 Southold, NY 11971-0959 January 11, 2012 Timothy Kilcommons 1000 Water Terrace Southold, NY 11971 kpF SOUjyo� COW, BUILDING DEPARTMENT TOWN OF SOUTHOLD TO WHOM IT MAY CONCERN: The Following Item(s) Are Needed To Complete Your Certificate of Occupancy: Application for Certificate of Occupancy. (Enclosed) Electrical Underwriters Certificate. _/ A fee of $25.00. Final Health Department Approval. Telephone (631) 765-1802 Fax(631)765-9502 Plumbers Solder Certificate. (All permits involving plumbing after 4/1/84) Trustees Certificate of Compliance. (Town Trustees #765-1892) Final Planning Board Approval. Final Fire Inspection from Fire Marshall. — Bob Fisher Final Landmark Preservation approval. BUILDING PERMIT: 34599 — Solar Panels Town Hall Annex 54375 Main Road P.O. Box 1179 Southold, NY 11971-0959 April 30, 2012 Timothy Kilcommons 1000 Water Terrace Southold, NY 11971 �pF SOCA 01 Ur�o� • �� COUNTY � `� BUILDING DEPARTMENT TOWN OF SOUTHOLD TO WHOM IT MAY CONCERN: The Following Items Are Needed To Complete Your Certificate of Occupancy: Application for Certificate of Occupancy. (Enclosed) Electrical Underwriters Certificate. (contact your electrician) A fee of $25.00. Final Health Department Approval. Telephone (631) 765-1802 Fax (631) 765-9502 Plumbers Solder Certificate. (All permits involving plumbing after 4/1/84) Trustees Certificate of Compliance. (Town Trustees # 765-1892) Final Planning Board Approval. (Planning # 765-1938) Final Fire Inspection from Fire Marshall. Final Landmark Preservation approval. BUILDING PERMIT: 34599 — Solar Panels Town Hall Annex 54375 Main Road P.O. Box 1179 Southold, NY 11971-0959 February 6, 2015 Timothy Kilcommons 1000 Water Terrace Southold NY 11971 BUILDING DEPARTMENT TOWN OF SOUTHOLD TO WHOM IT MAY CONCERN: The Following Items (if Checked) Are Needed To Complete Your Certificate of Occupancy: Application for Certificate of Occupancy. (Enclosed) Electrical Underwriters Certificate. V/ A fee of $50.00. Final Health Department Approval. Plumbers Solder Certificate. (All permits involving plumbing after 4/1/84) Trustees Certificate of Compliance. (Town Trustees # 765-1892) Final Planning Board Approval. (Planning # 765-1938) Final Fire Inspection from Fire Marshall. Final Landmark Preservation approval. Final inspection by Building Dept. Final Storm Water Runoff Approval from Town Engineer BUILDING PERMIT — 34599 — Solar Panels Telephone (631) 765-1802 Fax (631) 765-9502 JOB No. UU-26 R-25.00' Le40.07 TAX I.D. No. 1000-88-06-13.24 LOTS 7 AND 8 S 39° 14'09"E 15.00' =3 0.00' j_- 7.96 ' THE LOCATION OF WELLS, WATER SERVICE LINES, SEPTIC TANKS AND CESSPOOLS TIE 254.W r SHOWN HEREON ARE FIELD OBSERVA. COK PLTI Ito LOS 2ti TIONS AND OR DATA OBTAINED PROM LP2 O LPS 67.0' �I rn LOT 23 LPI O 0SEPTIC ' Unauth z"d WWabm a add'Uw to Cris docemerd is a Vholation d Sod= 7X8 or the New York State Educ bm Law —� , >r aj N 0 ;rAlubun IMW Gerson and b the aec�gnoes a the ler4ing ,na;hutonsor S WXegyent gnnerS . 38.5• A 13.4 22.0 j GAR & Z BAYVIEW, TOWN OF SOUTHOLD w i✓ 22.0 �ps _ z 9 33.4 L 2.0 GI J t ST OM O D Vi W T FRAM£ O m m ��FFC�LK Mmm DEP4.'t4 4' ''T —"~�-�--• COMMONWEALTH LAND TITLE INSURANCE COMPAN cNAn �rl"fiOVAL0► pNp4LTHSQty "sr WORM m N :uC� Y p0a n�a �Q� 2 Q 20 R� Point, N.Y. 11778 __ By D S'iIN G GRAF N.Y S. LIC N0. 50057 SEPTIC LOCATIONS Wlpm-du�Qfl�d � �%IAtY lkftJ IMne btu .� FOR a l�y tnl: CORNER A CORNER 8 13&DR � _ (,+�;;�� �f • SEPIC 18 58 LPI 27 69 29 04. _, `p n� j ~'`` � L11^# _ LP32 � N �_ THE LOCATION OF WELLS, WATER SERVICE LINES, SEPTIC TANKS AND CESSPOOLS SHOWN HEREON ARE FIELD OBSERVA. TIONS AND OR DATA OBTAINED PROM OTHERS. FILE MAP No. 9727 823/95 Unauth z"d WWabm a add'Uw to Cris docemerd is a Vholation d Sod= 7X8 or the New York State Educ bm Law —� Ceryacan n% tenanted hereon Shea nen —y to the person for wnoni it is prepared and m rh,s behaC to two Title Company, GMrnmental Agency and Lending SURVEY OF: LOT 22 ;rAlubun IMW Gerson and b the aec�gnoes a the ler4ing ,na;hutonsor S WXegyent gnnerS MAP OF ANGEL SHORES c:op,es d tr,f daurrwm not baarm9 the Pr Wi ,y rs mxsd seal a arlrbossed saal"itnutto(ZnldaledavaW".-py ' he insets j BAYVIEW, TOWN OF SOUTHOLD or O,Tenporhs j shown ^.eredn hum itYCerea .mpr r Anes are to a spechnU purpose and use and 'herelcn are npt m'andcd to gu,da the awbon of !enCes reL,naq "116 Poole. pianLng areas, addd o 1p Wild ngs or any oarer :on Wu . SUFFOLK COUNTY, NEW YORK 7•»*xlslen-riintowj-r,ntaways anyeY easoments dreccxd if any not snows are QUI QWranlCe�.j _ SURVEY DATE: 10/25/00 SCALE: 1,!_50' CERTIFIED ONLY TO: -j TIMOTHY J. KILCOMMONS AND MARY E. KILCOMMONS �P�- r' ` STIN G.GRAF y COMMONWEALTH LAND TITLE INSURANCE COMPAN DESTIN ^ GrnFpA D SURVEYOR _ BNY MORTGAGE COMPANY L L.C. I RH80001614 j m 73') odlawn Road R� Point, N.Y. 11778 __ By D S'iIN G GRAF N.Y S. LIC N0. 50057 A S NOsooed� 21-3442 MSC4Y/ Jpg (JFLU Image, 2JJUX:33U4 pixels) - scaled (19%) hrips://webmail.opbnwn.net/attach/hpsc497 jpg?sid--&moor--MOX&., New York State Insurance Fund Workers' Compensation & Disability Benefits Specialists Since 1914 8 CORPORATE CENTER DR, 3RD FLR, MELVILLE, NEW YORK 11747-3129 Phone: (631)76643W CERTIFICATE OF WORKERS' COMPENSATION INSURANCE GO SOLAR INC 272 MAIN RD RIVERHEAD NY 11901 POLICYHOLDER GO SOLAR INC 272 MAIN RD RIVERHEAD NY 11901 POLICY NUMBER CERTIFICATE NUMBER 11346970-5 579480 I CERTIFICATE HOLDER TOWN OF SOUTHOLD BUILDING DEPARMENT TOWN HALL SOUTHOLD NY 11971 _._- - - ---------------- 1 ----- 1 PERIOD COVERED BY THIS CERTIFICATE DATE 02/09/2009 TO 02/09/2010 ! 4/3/2009 THIS IS TO CERTIFY THAT THE POLICYHOLDER NAMED ABOVE IS INSURED WITH THE NEW YORK STATE INSURANCE FUND UNDER POLICY NO. 1346 970-5 UNTIL 02/09/2010, COVERING THE ENTIRE OBLIGATION OF THIS POLICYHOLDER FOR WORKERS' COMPENSATION UNDER THE NEW YORK WORKERS' COMPENSATION LAW WITH RESPECT TO ALL OPERATIONS IN THE STATE OF NEW YORK, EXCEPT AS INDICATED BELOW, AND, WITH RESPECT TO OPERATIONS OUTSIDE OF NEW YORK, TO THE POLICYHOLDER'S REGULAR NEW YORK STATE EMPLOYEES ONLY. IF SAID POLICY IS CANCELLED, OR CHANGED PRIOR T002109/2010 IN SUCH MANNER AS TO AFFECT THIS CERTIFICATE, 10 DAYS WRITTEN NOTICE OF SUCH CANCELLATION WILL BE GIVEN TO THE CERTIFICATE HOLDER ABOVE. NOTICE BY REGULAR MAIL SO ADDRESSED SHALL BE SUFFICIENT COMPLIANCE WITH THIS PROVISION. THE NEW YORK STATE INSURANCE FUND DOES NOT ASSUME ANY LIABILITY IN THE EVENT OF FAILURE TO GIVE SUCH NOTICE. THIS CERTIFICATE DOES NOT APPLY TO BUILDING DEMOLITION. THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS NOR INSURANCE COVERAGE UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICY, NEW YORK STATE INSURANCE FUI DIRECTOR,iNSURANCE FUND UNDERWRITING This certificate can be validated on our web site at https://www.nysif.comleert/certval.asp or by calling (888) 875-5790 VALIDATION NUMBER: 76580459 U-26.3 1 of 1 4/5/2009 8:46 PM npsc4y34pg (JYhU Image, 233W:om pixels) - scaled (I Y%) https://webmaii.opt numl.net(attach/hpsc495 jpg?sid=&mUox=INBOX&.. 04/03/2009 14:53 FAX Q001/002 ' 1. CERTIFICATE OF LIABILITY INSURANCE °"' 44031 009 ��� o4ro32008 PRODUCER LoVullo Associates, Inc. 6450 Transit Road Depew, NY 14043 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS INSURERS AFFORDING COVERAGE NAIL 8 INSURED Go Solar, Inc. - 27 Gary Minnick 272 Main Road .Riverhead, NY 11901 INSURERA, SCOTTSDALE INSURANCE COMPANY 41297 INSURERS. SCOTTSDALE INSURANCE COMPANY 41297 INSURER c: INSURER D: SOUTHOLD, NY 11971 INSURER E: POLICY EPPa.TNE THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FORTHE POLICY PERIOD INDICATED, NOTWITHSTANDING SHOULD ANYOF THE ABOVE DESCRIBED POLICE88E CANCELLED BEFORE THE 8WIRATION ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. AGGREGATE LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. BISR BUILDING D DEPARTMENT DEPARTMENT ULB IMPOSE NO OBLIGATION OR LILITY OF ANY AND UPON THE INSURER, ITS AGENTS OR TOWN HALL REPRESENTATIVES. SOUTHOLD, NY 11971 POLICY NUMBEq POLICY EPPa.TNE POLNY EIONMTgN uMITs CPS0934428 10/2012008 10720/2009 EACH occuRRMNCE f 1,000,000 A B NERAL LIABILITY COMMERCIAL GENERAL LIABILITY PREMISES JE--) S 100,000 EXP Imy Pne person) f 5,009 CLAIMS MADE [K]OCCMED PERSONAL A ADV INJURY f 1,600,900 GENERAL AGGREGATE f 2,600,660 GENL AGGREGATE LIMIT APPLIES PER: PRODUCTS-COMPADPAGG f 1,600,660 51 POLICYF7 PRO- 17 LOC AUTOMOBILE UABIUTY COMSIFIED SINGLE LIMIT ANYAUTO (EA ecndeml S ALL DINNED AUTOS --'— SCHEDULED AUTOS BODXYINJURY S (Per person) HIRED AUTOS BODILY INJURY f (Per A—IAM) '— NON.OWNED AUTOS PROPERTYDAMAGE (Per ecodeM) S GARAGE UASLITY AUTO ONLY -EA ACCIDENT S ANY AUTO OTHER THAN EAACC S - - AUTO ONLY. AGG S -- EXCESS IUMLMI-LLA LMILRY EACH OCCURRENL£ $ OCCUR Ei CLAWS MADE AGGREGATE S --- S DED UCV.E RETENTX71! S f WORRM f LOYER IUABIUN AND EttPLOYERY UA&LITr wCSTATk oTH- ANY PROPRIETOR)PAMNEWEXECUTNE YIN - d OKICERN (EMBER EXCLUDED? ❑ IMIYIdeOelY ti nHl E.L. EACH ACCIDENT f ryNlA deYDloe under E.L. DISEASE -Ew EMPLOYEE f $PECW. PROVISpN^ oelaw OTHER Property. E.L. DISEASE - POLICY LIMIT f A CPS0934428 10202008 10120!2009 Business Personal Deductible 80,000 DESCRWnON OF OIERATIONS / LOCATIONS ( VEMCLES I EXCLUSIONS ADD® BY ENDORSEMENT I SPECIAL PROVISIONS 1,000 l^CRTICIr:ATG Yfl1 IICe W Taee-zuua Act)RU CORPORATION. All rights reserved. The ACORD name and logo are registered marks of ACORD For more information contact: Walter P Geoghan Agency Inc at 631-4725000. of 1 4/5/2009 8:34 PM SHOULD ANYOF THE ABOVE DESCRIBED POLICE88E CANCELLED BEFORE THE 8WIRATION DATE THEREOF, THE ISSUING INSURER VALL ENDEAVOR TO MAL 10 DAYS WMTTEN TOWN OF O NOTICE TO THE CERTIFICATE HOLDER NAAI MED TO THE LEFT, BUT FAILURE TO DO SO SHALL BUILDING D DEPARTMENT DEPARTMENT ULB IMPOSE NO OBLIGATION OR LILITY OF ANY AND UPON THE INSURER, ITS AGENTS OR TOWN HALL REPRESENTATIVES. SOUTHOLD, NY 11971 AUTHORIZED REPRESENTATIVE ACORD 25 2009/011 W Taee-zuua Act)RU CORPORATION. All rights reserved. The ACORD name and logo are registered marks of ACORD For more information contact: Walter P Geoghan Agency Inc at 631-4725000. of 1 4/5/2009 8:34 PM The Xantrex Grid Tie Solar Inverter (GT Series) is designed to convert photovoltaic (PV) electricity produced by solar modules into utility -grade power that can be used by the home or sold to the local electrical utility. Offering high efficiency (up to 96.0 %), clean aesthetics, high reliability, and a low installed cost, through ease of installation and integrated features, the GT Series is a proven, high -frequency design in a compact enclosure. The GT Series may be installed as a single inverter, for a single PV array, or in a multiple -inverter configuration for large PV arrays. Technology ► An NEC compliant, integrated DC/AC disconnect, standard in the GT Series, eliminates the need for external DC (PV) disconnects, and in some jurisdictions, AC disconnects ► large heat -sink offers extraordinary heat dispersion without the need for a cooling fan ► Liquid crystal display (LCD) provides instantaneous information — power level, daily and lifetime energy production, PV array voltage and current, utility voltage and frequency, time online "selling", fault messages, and installer -customized screens ► LCD vibration sensor allows the tap of a finger to turn backlight on and to cycle through display screens ► Free PC software for remote monitoring and system troubleshooting available online Installation ► Flexible module selection and sizing due to wide PV input MPPT tracking voltage range ► Lightweight and versatile mounting bracket ► Easy access DC (photovoltaic) and AC (utility) terminal block simplifies wiring ► Rugged NEMA 3R inverter enclosure allows reliable indoor and outdoor installations Performance ► Best -in -class efficiency to maximize solar system return on investment ► Accurate MPPT tracking ensures maximum energy harvest under any conditions ► FCC Part B compliance provides less external electronic interference Serviceability ► 10 -year standard warranty ► Sealed inverter enclosure can be quickly separated from the wiring box allowing DC/AC connections to remain intact in the unlikely event the inverter needs to be serviced Standard 10 -year warranty PHOTOVOLTAIC �" � 07-0' POWER INVERTER c us Xantrex Technology Inc. Customer Serviceffechnical Support customerservice®xantrex.com Toll free: 1-800-670-0707 www.xantrex.com mntrex Standard 10 -year warranty PHOTOVOLTAIC �" � 07-0' POWER INVERTER c us Xantrex Technology Inc. Customer Serviceffechnical Support customerservice®xantrex.com Toll free: 1-800-670-0707 www.xantrex.com Smart choice for power xantrex Xantrex GT Series Grid Tie Solar Inverters p, ifix • .... ,xreTb`7�'.",�amvs Fi,%�»'kti.: . ModNe GT5.0 GT4.ON GT3.3N GT2.8 Output 240 V 208V 240 V 208 V 240 V 208V 140 V 208 V Max. AC power output 5000 W 4500 W 4000 W 3800 W 3300 W 3100 W 2800 W 2700 W AC output voltage (nominal) 240 V 208 V 240 V 208 V 240 V 208 V 240 V 208V AC output voltage range 211-264 Vac 183.229 Vac 211-264 Vac 183.229 Vac 211-264 Vac 183-229 Vac 211.264 Vac 183-229 Vac AC frequency (nominal) ; 60 Hz AC frequency range 59.3.60.5 Hz Startup current 0 Aac Max. continuous output current 21 A 22 A 16.7 A 18.3 A 13,8A 14.9 A 11.7 A 13.0 A Max. output over -current protection 30A 25A 20A 15A Max. output over -current protection 30 Arms 25 Arms 20 Arms 20 Arms Max. utility backfeed current 0 A Total harmonic distortion (THD) <31% - <5% - Power factor > 0.99 % (at rated power), > 0.95 % (full power range) Utility monitoring islanding protection UL1741-20051 IEEE 1547 Output characteristics Current Source Output current waveform True sine wave R v" apg Y r fx w&§ F a +y Max. array open -circuit voltage 600 Vdc MDPT voltage range (CEC & CSA) 240 - 550 Vdc 240 - 480 Vdc 200 - 400 Vdc 195 - 550 Vdc MPPT operating range Low: 235 Vdc I High: 550 Vdc Low: 235 Vdc / High: 550 Vdc low: 200 Vdc I High: 550 Vdc Vdc Low. 193 Vdc / High: 550 Vdc Max. input current 22.0 Adc 20.0 Adc 18.0 Adc 17.0 Adc 17.5 Adc F 16.5 Adc 15.4 Adc 14.9 Adc Max. array short-circuit current 24.0 Adc Reverse -polarity protection Short-circuit diode Ground -fault protection GF detection, IDIF > 1 A Max. inverter efficiency 95.9% 95.5% I 96.0% 95.7% 95.9% 95.6% 95.0% 94.6% i CEC efficiency 95.5% 95.0% 95.5% 95.0% 95.5% 95.0% 94.0% 93.5% Night-time power consumption 1 W Operating temperature range I -13°F to +149°F (-25°C to +65°C) Enclosure type NEMA 3R (outdoor rated) Inverter weight 58.0 Ib (25.8 kg) 58.0 Ib (25.8 kg) 49.0 Ib (22.2 kg) 49.0 Ib (22.2 kg) Shipping weight 65.0 Ib (27.2 kg) 65.0 Ib (27.2 kg) 57.0 Ib (25.9 kg) 57.0 Ib (25.9 kg) Inverter dimensions (H x W x D) 28 1/2 x 16 x 5 3/4' (724 x 403 x 145 mm) Shipping dimensions (H x W x D) 34 x 201 /2 x 10 5/16" (866 x 518 x 162 mm) Mounting Wall mount (mounting bracket included) Input and output terminal AC and DC terminals accept wires sizes of #14 to #6 AWG PV / Utility disconnect Flimindtes need for cxtefnai PV (DC) disconnect. Complies with NEC i(quirements Cooling Convection cooled, fan not required Display Backlit, two-line, 16 -character liquid crystal display provides instantaneous power, daily and lifetime energy production, PV array voltage and current utility voltage and frequency, time online 'selling', fault messages, and installer -customizable screens Communications Integrated RS232 and Xanbusr" RJ45 communication ports Wiring box PV, utility, ground, and communications connections. The inverter can be separated from the wiring box Warranty 10 -year standard Model name (negative ground) GT5 O NA 140808 UI OS Gi4 ON NA -1401208 UL OS GT3 3N NA 1401208 UL.05 G12,8 -NA -240/208 UL 05L Part number (negative ground) 864-1009 864-1008 8641006 864-1001 Positive ground inverters are also evadable I Sprcificawnn tubµYi to thaix)e wnhoul nut¢e. I 225 SOLAR PANEL EXCEPTIONAL EFFICIENCY AND APPEARANCE Peak Power (+1-5%) Pmax 225 W Rated Voltage Vmp 411.0V Rated Current Imp 5.49 A Open Circuit Voltage Mac 48.5 V Short Circuit Current Isc 5.87 A Maximum System Voltage IEC, UL 1000 V, 600 V Temperature Coefficients UL listed (UL 1703), Clan C Fire Rating Power -0.38% /*C Voltage (Voc) -132.5 mV/ -C Current (Isc) 3.5 mA/OC Series Fuse Rating 20A Peak Power per Unit Area 181 W/m2, 16.8 W/1112 CEC FTC Rating 207.1 W Solar Celts 72 SunPower all -back contort monocry"ine Front Glass 3.2 mm (1/0 in) tempered Junction Box IP -65 rated with 3 bypass diodes Output Cables 900mm length cable / MulfiContoct connectors Frame Anodized aluminum alloy type 6063 Weight IS kg, 33 lbs — (.4 7.0 6.0 5.0 94.0 3.0 2.0 1.0 0.0 1000 W/m, 800 w/ m2 500 W/M' 0 10 20 30 40 50 60 Voltage M Current/voltage characteristics wilh dependence on irradion and modu64omperoture, Temperature -- -40° C to +90* C (-40*F to +1941) -------- Max load 50 psf (2400 pascals) hw and back Impact Resistance Hall -25mrn (I W4 at 23 m/s (52 #n* Warranty 25 year limited power warranty 10 yaw limited product warrant' Certifications IEC 61215, Sof* tested IEC 61730 UL listed (UL 1703), Clan C Fire Rating LBO 1200 0 4,21161 (7 NJ J47 241 r I G—d) 1� v15+ 122 BllOnfIM �1f ' Eq 2 I � 2M II I 7S4 120" CAUTION: READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT "J'fo' "!I .7!7 SunPower designs, manufactures and delivers high-performance solar electric technology worldwide. Our high -efficiency solar cells generate up to 50 percent more power than conventional solar cells. Our high-performance solar panels, roof tiles and trackers deliver significantly more energy than competing systems. Z oc"11.1 200 S-9— 4 ;J!'T' .--d .0-1 na c. Do,*,t 4001 42 188 11- i,i411* Printed on recycled paper www.sunpowercorp.com SPR-225-BLK 225 SOLAR PANEL EXCEPTIONAL EFFICIENCY AND APPEARANCE The SunPower 225 Solar Panel provides a revolutionary combination of high efficiency and attractive, uniform appearance. Utilizing 72 next generation SunPower all - back contact solar cells and an all -black backsheet, the SunPower 225 elegantly delivers an unprecedented total panel conversion efficiency of 18.1 %. The panel's reduced voltage -temperature coefficient and exceptional low -light performance attributes provide for higher energy delivery per peak power than conventional panels. SunPower's High Efficiency Advantage - up to 50% More Power Walls / Panel 165 Efficiency 12.0% kWs 3.0 A C E C&s Inverters: 2 Provided (see attached specifications) PV modules: 39 Provided (see attached specifications) Legend - DC Positve AC Hot DC Negative Ground PV MODULE FRAMING AND MOUNTING SYSTEM FOR PITCHED ROOFS Module Compatibility Use SunFrame with PV modules from these major manufacturers: BP Solar, GE Energy, Isofoton, Kyocera, Mitsubishi, Photowatt, RWE Schott, Sanyo, Sharp. Call UniRac or your PV dealer for manufacturers not listed. Code Compliance SunFrame is designed to comply with the Uniform and California building codes when installed according to SunFrame installation instructions. Call UniRac concerning status of International Building Code compliance. Components O Inter -Module Rails support modules as little as 2.125 inches above the roof. © Full Length Cap Strips secure modules and finish the array topside forming a gap -free frame. Self - tapping screws at 16 -inch intervals provide the holding power. © Push -Fit End Caps neatly finish the rail ends. 0 L -Feet attach directly to asphalt shingle roofs and support the rails one-half to three-quarters of an inch above the roof surface to provide convective ventilation. 0 Splices safely extend rails. O Aluminum or Steel Standoffs (optional) in a range of heights sup- port L -feet above tile or shake roofs. UniRac offers appropriate flashings. Clear or dark finishes on all visible above -roof components, from L -feet to screw heads, match the frames of your PV modules. Component Specifications Rails, cap strips, two-piece standoffs, splices, and L -feet: 6105 T5 aluminum extrusion. End caps: UV resistant plastic. One-piece standoffs: Service Condition 4 (very severe) zinc -plated welded steel. Fasteners: 304 stainless steel. www.unirac.com See our SunFrame page for complete information: pricing, installation instructions appropriate to your build- ing code, and minimum requirements for the number and type of modules you plan to mount. UnMac, Inc. 3201 University Boulevard SE, Suite 110 505.242.6411 Pub 050206.1 ds • February 2005 info@unirac.com Albuquerque NM 87106-5635 USA 505.242.6412 Fax ) 2005 UniRac, Inc. All rights reserved. 10 year limited Product Warranty, 5 yew limited Finish Warranty UniRac, Inc.. warrants to the original purchaser I"Purchaser") of practices specified by HAMA 609 & 61102 - 'Cleaning and product(s) that it manufactures (`Product') at the original instal- Maintenance for Architecturally Finished Aluminum" lation site that the Pmduct shall M! frre from defrrts in material (www.aamanet org) am nrn followed by Purchase, This Warranty .md wnrkn nchip fur a Iunod ,f ten x. 101 seors, exewpl for the 1-1 not melt daunge to the product that nru , during as anudized finish, which finish shall be free hum visible peeling, orshipment, storage, or in.+ralmion. cracking or chalking under normal atmospheric onditions for a rtes Wnn:mn shall I.. VOID if m,tallatioo of rhe Pnduct is not L•n i of toce (S) .cats, Inim ill � ar5er t( 1) the d;ue the hula( pctfnrmed in accVntar cr ssith CniRac's i urn inscdlunon I:nton of the product is completed, of 2) 3u days rite, the purchase nurrucuoos, or it till Product has 1-1 nn>,hh r1, ie)+ain•d, ur of the Pnxluu by the onginal Pan hart 1 Pimsh Darr inn"t. i—akc l m t mannrr nut hnv ,i iy i fl<I t v R I unc IN The Finish Warr:mty does its applt to oIY tunt},n t lite WI+ITING, or a du' Pnxhiu n I t IInl in an 1ro deposited on the finish. All irioallatioms in corrosive atillospilefic which it was our 1 Igned Un iit .hall nor be .iahle I n conditions arc excluded Tie Finish W irmry is VOID if the ruusegiwritml, i ntingem or incidental darn+gcs u1s1119 iut 11 the use of the Product by Purchaser under any circumstances. If within the specified Warranty periods the Product shall be maamably proven to he defective, then UniRac shall repair or a•IJoce the d,-,fective product, or any part thereof, in UmR.6 sole discretion. Such repair or replacement shall completely satisfy ,and di.+rharge all of UmRac's liability with respect to this limited War,iots ;'nder no cv 1"Wit ceS shall 1.n,Rar he Bahl. for ,I,rctal, indirect or consequential damages arising oW of n I o, 1 to use hs Purchaser of the product L1 m.d,rrran n I inland u m sur n a FN r lines tui Ili h ngs, 111,1V ,-dc wtioeo murumics ul their own. I.mRac s linoied '71 itrann hovers only its 1'nduct and not any related items. THE STANDARD IN PV MOUNTING STRUCTURES aD & lk;Flm Add Aesthetics to the Benefits of PV Power With your array in (till vleVV, it has to look great. SunFrame delivers the visual appeal you and your neighbors expect. ki Properly installed, SunFrame complies %vith the Uniform and California Building Codes. It also meets UniRac's own high standard of installation friendliness, both initially and whenever modules need replacement. But it is aesthetics that truly sets SunFrame apart. It's the only PV module mounting system designed from the outset to enhance the appearance of the home. A completed installation blends handsomely into the roof, becoming as natural a part of the house as a skylight. GLNERAL NOTES mean roof height 22 ft pitch 7 in on 12 in � O 1. CONTRACTOR SHALL CHECK AND VERIFY ALL CONDITIONS AT THE 11. THE OWNER SHALL SELECT ALL FINISH MATERIALS AND COLORS. 12 1 roof rafter 2x0 SITE PRIOR TO STARTING TO WORK AND SHALL FAMILIARIZE 12. THESE DRAWINGS AS INSTRUMENTS OF SERVICE ARE AND SHALL rafters acin 16 inch on center OCCUPANCY 0 F HIMSELF WITH THE INTENT OF THESE PLANS AND MAKE WORK REMAIN THE PROPERTY OF THE ENGINEER WHETHER THE PROJECT p 9 AGREE WITH SAME. FOR WHICH THEY ARE MADE IS EXECUTED OR NOT. THEY ARE 2. CONTRACTOR OR OWNER SHALL OBTAIN ALL REQUIRED APPROVALS, NOT TO BE USED ON ANY OTHER PROJECTS OR EXTENSIONS TO SEE DET. 1 ceiling joist 2X6 PERMITS, CERTIFICATES OF OCCUPANCY, INSPECTION THIS PROJECT EXCEPT BY AGREEMENT IN WRITING AND WITH Y' joist $ acin 16 inch on center APPROVALS, ETC., FOR WORK PERFORMED FROM AGENCIES HAVING APPROPRIATE COMPENSATION TO THE ENGINEER. spacing U I S U N LA W F i JURISDICTION THEREOF, IF REQUIRED. 13. CONTRACTOR SHALL PROTECT, PATCH AND REPAIR ALL EXISTING WORK ADJACENT TO HIS WORK. ridge qty 1 WITHOUT /r T I�—{' R T 7 3. ALL WORK SHALL CONFORM TO N.Y.S. CONSTRUCTION CODE AND OR DAMAGED AS RESULT OF HIS WORK. \ ridge 2x1 0 f �r 1 1 1 1 0 U� C E 1 t 1 I k� , ALL RULES AND REGULATIONS OF THE RESPONSIBLE JURISTICTION. 14, THE SUBCONTRACTORS SHALL PROVDE ALL EQU�LIENT, TOOLS. FENCES. TRANSPORTATIONS, - 4. ALL METHODS OF CONSTRUCTION ARE TO BE CAREFULLY SEE DET. 1 SAFEGUARDS, ETC., AS REQUIRED FOR THE PROPER EXECUTKIN OF TRENT WORK. SUPERVISED BY THE CONTRACTOR. COIIar ties 2X4 5. IF IN THE COURSE OF CONSTRUCTION A CONDITION EXISTS 15. CONTRACTOR TO EFFECT AND MAINTAIN INSURANCE, LE. CONTRACTOR'S LIABILITY, WORKMANSOF WHICH DISAGREES WITH THAT AS INDICATED ON THESE PLANS. COMPENSATION, COMPLETED OPERATION,ETC. ADEQUATE FOR THE PURPOSES OF THIS PROJECT AND collar tie spacing every third rafter CUPANC I THE CONTRACTOR SHALL STOP WORK AND NOTIFY THE ENGINEER. FURNISH PROOF OF SAME PRIOR TO COMMENCING WITH WORK. SHOULD HE FAIL TO FOLLOW THIS PROCEDURE AND CONTINUE 16. EACH SUBCONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING SAFETY ON THE JOB SITE DURING WITH THE WORK. HE SHALL ASSUME ALL RESPONSIBILITY AND THE CONSTRUCTION PHASE TO COMPLY WITH THE REGULATIONS AND REQUIREMENTS OF THE Roof Cross Section LIABILITY THEREFROM. OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION. THIS SHALL INCLUDE, BUT ARE NOT LIMITED T0: 6. ALL STRUCTURAL STEEL SHALL BE A-36 AND SHALL BE PROVIDING FOR ADEQUATE AND PROPER BRACING. SAFETY RAILINGS AND SECURE FOOTINGS FOR ALL FABRICATED AND INSTALLED AS PER LATEST A.I.S.C. TEMPORARY SCAFFOLDING, STAIRS, ETC., AS WELL AS PERMANENT CONSTRUCTION. N. tT . S SPECIFICATIONS. 17. FIGURED DIMENSIONS SHALL GOVERN. DO NOT SCALE DRAWINGS. WHERE DIMENSIONS ARE 7. ALL DRYWALL SHALL BE U.S.G. NATIONAL GYPSUM CO. 5/8' ESTABLISHED BY EXISTING CONDITIONS, EACH CONTRACTOR SHALL VERIFY EXISTING CONDITIONS PURSUANT TO CHAPTER AFTER ��� THICK UNLESS OTHERWISE NOTED. PRIOR TO ORDERING MATERIALS AND COMMENCING WITH WORK. H B. ALL ELECTRICAL WORK SHALL BE BOARD OF FIRE UNDERWRITERS 18. CONTRACTOR SHALL COORDINATE ALL PHASES OR WORK WITH THE REQUIRED PARTIES. ALL 0 F THE TOWN CODE. - APPROVED AND IN ACCORDANCE WITH N.E.C. & NYS PHASES OF ADJACENT FACILITIES OPERATIONS SHALL BE MAINTAINED DURING CONSTRUCTION. ' CODES REGULATIONS. CONTRACTOR SHALL KEEP SITE FREE OF CONSTRUCTION DEBRIS AND KEEP SITE FULLY ACCESSIBLE 9. ANY DEVIATION FROM THESE PLANS WITHOUT THE WRITTEN TO THE PUBLIC DURING HOURS OF OPERATION. VAPPRVEDAS NOT UNDERWRITERS CERTIFICA CONSENT OF THE ENGINEER WILL NEGATE THE ENGWEER'S �CERTIFICATION OF THESE PLANS. 19. CONTRACTOR TO REMOVE ALL DEBRIS CREATED BY THIS WORK FROM THE SITE AND DISPOSE OF 10. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR CUTTING, IN A LEGAL MANNER ON A WEEKLY BASIS OR SOONER IF CONDITIONS WARRANT. B.P. # FITTING OR PATCHING REQUIRED TO COMPLETE THE WORK OR TO 20. AT THE COMPLETION OF WORK, THE SITE IS TO BE CLEARED OF ALL DEBRIS AND EXCESS DATE: - I MAKE ITS PARTS FIT TOGETHER PROPERLY. MATERIALS. THE FACILITY IS TO BE LEFT BROOM CLEAN AND WORK IS TO BE COMPLETED TO �l7V THE TOTAL SATISFACTION OF THE OWNER PRIOR TO RELEASE OF FINAL PAYMENT. FEE: - U V BY: CONDUIT NOTIFY BUILDING DEPARTMENT AT FROM ARRAY 765-1802 8 AM TO 4 PM FOR THE FOLLOWING INSPECTIONS: 1. FOUNDATION - TWO REQUIRED INVERTER INVERTER ,- FOR POURED CONCRETE 2. ROUGH - FRAMING & PLUMBING 3. INSULATION 4. FINAL - CONSTRUCTION MUST DC METER gE COMP R C.O. WIRING GUTTER _ L CO., STI IUCTION HALL MEET THE �. TS OF TH CODES OF NEW DISCONNECT RK STAT -Sqf0IC9SPO E FOR 4 DESIGN OR dTIO A RORS. AC DC 3 Mia Clamp TYPICAL RISER DIAGRAM CERTIFICATION OF NAILING & CONNECTIONS N.T.S. REQUIRED. a Eno Clamp L -foot''!, SolorMount Rog 77... `l �: Revision 5 SolgrMount Rai- ('0F . r , t • � ' � Revision 4 1f J Ui Iv— C. Revision 3 TYPICAL CONNECTION DETAIL 1 ALL ROOF PENETRATIONS ARE TO BE SEALED Revision PV PANEL WITH SIKAFLEX OR EQUIVALENT SEALANT Revision 1 as per ASCE7, Method 1: A (fig 6-2) 1.314 1 (table 6-1) 1 PA4 1 1 O ENONEERING PC P net = A Kzt / P net3o (eq 6-2) Kn (sec 6.5.7) 1 pnet30 (fig 6-3) Maxim m9 `�pf MOSS -0000 Box 44 Fax: 63Z, 382' 823 17 Email: a ivLeer@ acit'icoen ivLeeri cowl CLIMACTIC AND GEOGRAPHIC Wind Live load, Speed,3 pnet30 point Fastener fastener DESIGN, CRITERIA Category pullout spacing Tim Kikommons sec gust, per ASCE type load, Ib along mph 7, psf 1000 Water Terrace, Southold, NY 11.971 rails, in 5/16" dia ��� NNS �, �� PROPOSED SOLAR ENERGY INSTALLATION screw, F1`SS10 C 120 -34.0326 472 3-1/2" 32 • •••.........-• GENERAL NOTES, ROOF SECTION, DATA, DETAILS AND SPECS OIC Mt.: s-l�: length 021231o9 AS NOTED 351- 5" ROOF LAYOUT THIS CERTIFIES THAT THE ROOF LOAD HAS BEEN CHECKED FOR WIND, SNOW, LIVE AND DEAD LOADS BASED ON ASCE7-05 AND 2007 NYS BUILDING CODE. THE ROOF STRUCTURE IS ADEQUATE TO SUPPORT THE PROPOSEDLOADS !!!!M] PO 130X1448, SAYVILLE, NY 11782 631-988-0000 Fax: 631-382-8236 Email: Tim Ki%ommons 1000 Water Terrace, Southold, NY 11871 Revision 5 Revision 4 Revision 3 Revision 2 Revision 1 wjat Dcunpt- _. PROPOSED SOLAR ENERGY INSTALLATION GENERAL NOTES, ROOF SECTION, DATA, DETAILS AND SPECS )ate: Scalc. oz/za/ov AS NOTED z oFz PV Panel SunPower PRODUCT: 225 QTY: 39 LENGTH: 61.39 in WIDTH: 31.42 in WATTS: 8775 !!!!M] PO 130X1448, SAYVILLE, NY 11782 631-988-0000 Fax: 631-382-8236 Email: Tim Ki%ommons 1000 Water Terrace, Southold, NY 11871 Revision 5 Revision 4 Revision 3 Revision 2 Revision 1 wjat Dcunpt- _. PROPOSED SOLAR ENERGY INSTALLATION GENERAL NOTES, ROOF SECTION, DATA, DETAILS AND SPECS )ate: Scalc. oz/za/ov AS NOTED z oFz