Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
1000-52.-2-34
OFFICE LOCATION: Town Hall Annex 54375 State Route 25 (cor. Main Rd. & Youngs Ave.) Southold, NY 11971 MAILING ADDRESS: P.O. Box 1179 Southold, NY 11971 Telephone: 631 765-1938 Fax: 631765-3136 LOCAL WATERFRONT REVITALIZATION PROGRAM TOWN OF SOUTHOLD MEMORANDUM To: John Bredemeyer, President Town of Southold Board of Trustees From: Mark Terry, Principal Planner LWRP Coordinator Date: September 10, 2014 Re: Proposed Administrative Amendment to Wetland Permit #7771 JOHN PITMAN SCTM# 1000-52-2-34 JOHN PITMAN requests an Administrative Amendment to Wetland Permit #7771 for the as -built first and second floor covered porches (each +/-140sq.ft.); and to construct a set of 4'x3' steps leading to a 4'x4' landing to 4'x7' steps from first story porch to ground. Located: 1100 Ruch Lane, Southold. SCTM# 52-2-34 The proposed action has been reviewed to Chapter 268, Waterfront Consistency Review of the Town of Southold Town Code and the Local Waterfront Revitalization Program (LWRP) Policy Standards. Based upon the information provided on the LWRP Consistency Assessment Form submitted to this department, as well as the records available to me, it is my recommendation that the proposed actions are INCONSISTENT with the Policy Standards (Policy 6.3) and therefore are INCONSISTENT with LWRP. 6.3 Protect and restore tidal and freshwater wetlands. A. Comply with statutory and regulatory requirements of the Southold Town Board of Trustees laws and regulations for all Andros Patent and other lands under their jurisdiction 1. Comply with Trustee regulations and recommendations as set forth in Trustee permit conditions. The structures were constructed without a Wetland Permit and the benefit of Board of Trustees review. Pursuant to Chapter 268, the Board of Trustees shall consider this recommendation in preparing its written determination regarding the consistency of the proposed action. Cc: Lori Hulse, Assistant Town Attorney Town of Southold LWRP CONSISTENCY ASSESSMENT FORM A. INSTRUCTIONS 1. All applicants for permits* including Town of Southold agencies, shall complete this CCAF for proposed actions that are subject to the Town of Southold Waterfront Consistency Review Law. This assessment is intended to supplement other information used by a Town of Southold agency in making a. determination of consistency. *Except minor exempt actions including Building Permits and other ministerial permits not located within the Coastal Erosion Hazard Area. 2. Before answering the questions in Section C, the preparer of this form. should review the exempt :minor action list, policies and explanations of each policy contained in the Town of Southold Local Waterfront Revitalization Program. A proposed action will be evaluated. as -to" its significant 3: If any question in Section C on this form is answered "yes" or o", then the proposed action will affect the achievement of the LWRP policy standards and nditions contained in the consistency review law. Thus each answer must be ex lainM iw4etafl, listing both supporting and non - supporting facts. If an action cannot be certified as nsistent with the LWRP policy standards and conditions, it shall not be undertaken. A copy of the LWRP is available in the foll g places: online at the Town of Southold ' s website (southoldtown.northfork.net), the oard of Trustees Office, the Planning Department, all local libraries and the Town Yk'se. B. DES ON OF SITE AND PACTIONSCTM#AUG 1 8 2014 PROJECT N01 t; The Application has\ebened to ( eck appropriate response): Town Board ❑ rd Building Dept. ❑ Board of Trustees 1. Category of Tl agency action (check appropriate response): (a)Actionctly by Town agency (e.g. capital ❑constractivity, agency regulation, land transaction) ❑ (b) Financial assistance (e.g. grant, loan, subsidy) (c) Permit, approval, license, certification: Nature and extent of action: z�, tc �� A Location of action: Site acreage: Present land use: k -e S i J 01 An- 61 Present zoning classification: R- 4i) L"3C"-<-,-- 2. If an application. for the proposed action has been filed with the Town of Southold agency, the following information shall be provided: l (� (a) Name of applicant: (b) Mailing address: L �2 p Q i (c) Telephone number: Area Code ( )� (� 1 - S�' 9- l,' (d) Application number, if any: Te V 4'l t 4- 1+ -7 1 Will the action be directly undertaken, require funding, or approval by a state or federal agency? Yes ❑ No 4 If yes, which state or federal agency?. C. Evaluate the project to the following policies by analyzing how the project will further support or not support the policies. Provide all proposed Best Management Practices that will further each policy. Incomplete answers will require that the form be returned for completion. DEVELOPED COAST POLICY Policy 1. Foster a pattern of development in the Town of Southold that enhances community character, preserves open space, makes efficient use of infrastructure, makes beneficial use of a coastal location, and minimizes adverse effects of development. See LWRP Section III - Policies; Page 2 for evaluation criteria. ❑ Yes ❑ No tZ Not Applicable Attach additional sheets if necessary Policy 2. Protect and preserve historic and archaeological resources of the Town of Southold. See LWRP Section III - Policies Pages 3 through 6 for evaluation criteria ❑ Yes ❑ No 1[/-7'1J Not Applicable Attach additional sheets if necessary Policy 3. Enhance visual quality and protect scenic resources throughout the Town of Southold. See LWRP Section III — Policies Pages 6 through 7 for evaluation criteria ❑ Yes ❑ No V�j Not Applicable Attach additional sheets if necessary NATURAL COAST POLICIES Policy 4. Minimize loss of life, structures, and natural resources from flooding and erosion. See LWRP Section III — PoliciesPages8 through 16 for evaluation criteria Yes F-1 No !'" Not Applicable Attach additional sheets if necessary Policy 5. Protect and improve water quality and supply in the Town of .Southold. See LWRP Section III — Policies Pages 16 through 21 for evaluation criteria ❑ Yes F] No �A Not Applicable Attach additional sheets if necessary Policy 6. Protect and restore the quality and function of the Town of Southold ecosystems including Significant Coastal Fish and Wildlife Habitats and wetlands. See LWRP Section III — Policies; Pages 22 through 32 for evaluation criteria. annal "09 Yes No Not Applicable Attach additional sheets if necessary Policy 7. Protect and improve air quality in the Town of Southold. See LWRP Section III — Policies Pages 32 through 34 for evaluation criteria. F]Yes F] No" Not Applicable Attach additional sheets if necessary Policy 8. Minimize environmental degradation in Town of Southold from solid waste and hazardous substances and wastes. See LWRP Section III — Policies; Pages 34 through 38 for evaluation criteria. ❑ Yes ❑ No Not Applicable PUBLIC COAST POLICIES Policy 9. Provide for public access to, and recreational use of, coastal waters, public lands, and public resources of the Town of Southold. See LWRP Section III - Policies; Pages 38 through 46 for evaluation criteria. (� F] Yep- ] No Not Applicable Attach additional sheets if necessary WORKING COAST POLICIES Policy 10. Protect Southold's water -dependent uses and promote siting of new water -dependent uses in suitable locations. See LWRP Section III Policies; Pages 47 through 56 for evaluation criteria. ❑ Yes ❑ No 0 Not Applicable Attach additional sheets if necessary Policy 11. Promote sustainable use of living marine resources in Long Island Sound, the Peconic Estuary and Town waters. See LWRP Section III - Policies; Pages 57 through 62 for evaluation criteria. ❑ Yes ❑ No Not Applicable ` Attach additional sheets if necessary Policy 12. Protect agricultural lands in the Town of Southold. See LWRP Section III — Policies; Pages 62 through 65 for evaluation criteria. ❑ Yes ❑ No� Not Applicable Attach additional sheets if necessary Policy 13. Promote appropriate use and development of energy and mineral resources. See LWRP Section III — Policies; Pages 65 through 68 for evaluation criteria. ❑ Yes ❑ No " Not Applicable PREPARED BY, ) LD U f--� 1 -- 4 A TITLE DATE ------- ----FDRPtt s nD a - ,o\ N « t lM1� 6EE 9Ec n0 / 4\ A t' fr NO. t O xtt M•' ® \ E. � !f`'� ^.f ^p N •A ? ,I, b e BTib » a e€ jpNPuv°aRWnDD)j .I.6Alc1 ,x tµq \ u Nv �@ U 15v1 �'51Idc1 t ONcI ,1 O• 1.1Nc1 µBE0.TSW I ! scy`J.yo / i se w # sfi.a .� \\ t1.on(q t WI 9 I 10lYn OF 90DTHOLD Mr,' '^a' N.M6 I R' k lo \\ 11 B• PEcoNC — uxD r.usr "'NO 13 @12 \ ^r n• 3j E© •., 1 �a xaa . t5 aEa afic. M. FOR POL.NO. mal,o,,.! $EE SEO.NO. � \' ME— NO OS6M.Ola e3 a1o,.n, �! O56U10l1.11 w `d, — —�----------- - ----------------------- -------�.------- -- _ —.--- ——.__--- u _ x> yyy Pb @ MIRGM 6fE SEO.NO o.LINE SEE SEG n0056 F secr�oN no 52 —�— fx^•,,._ E 'µa czll r _ __ O _ ___ �•� _—q-- n.. ^ _ _,— _ _ _ --x-- ».. _ _».-- NoncE d".,;'�� COUNTY OF SUFFOLK © t,l.' Real Property Tax Service Agency .:I% >r, 6«.nl,e«N.rRFN.N.Nrttbl «r N M x aouFnoLD p..»» r.�at s '� `__�� �..+ --•-- .amu.--+nr-- erw . m P m m lncr xo tNe PROPCRTY MAP { e. s9/ z 1 - 11 U i Ilk .t e i 1 ; i, Of I �' [ r f .�f ', rj'+3��,AjF,s.'s]r�Wr�„ � i t, 7 �'x � N ... �.: ��"r f � ���r' �r ' t •,�E. t� f r•� �bj�ta' � ��y i J f'� yr,• A � �S;j:' " " �:: 'tX x.. ,.r r ♦y� 'a 3` ,.� �'� tr y!= z.r� r, • . r rJ i �,X�.. YJ, tt 3ti,,. ' r r , � , �' r �ye'�' `�*.��,� �• �1 u + r a r rr '1 3 T i{�� f /=At, � g,.5 ,�� A... ( °�e•` +°',�,J ,at r • kV! Ai 'i / r • yr !,, -t`jir, `"ii'�T{ 4 s•2'^ ,S E , • s �r jo �,, 3 'firs v A9 1y ` Iflr '.�tjjf'��FF f r � �•� r �����- °ir i�� ', .. � S � e .. �5.� �_} t"•' r� „�� tl �, �- �`' � - Si/�tlm��. 3 r x W � .s 3�AN 01 } I' 1 y W, 144 i r 'rF m i Y u X T I fiM1 �7 ww n 1�ij � _ j•' � f' t 1. t ` f > 5 �� •�. J �,. t _ �t v � �N, . i 1 2 ;1-.�5Y* �i d1 of � � �/� Wed s• �S*Y.�.� A A +tom t, r. r t�. N •y 48'-0" z _ Q rn 44'-0" 4'-0" Z DND D_ (2)-2x6 FS 26'-4 5/8" 33'-8 7/8" LJ y 5'-0" SPF#2 " PLUMB PLUMB u g'_0 19'-jQ" 2" PVC CHASE N AUG 1 8 2014 D : 3- x6 5 SP 2x6 FS HDR: 3-2x g TO 2ND FLR. 4�zx6 P #2 O 11'2 SPF #2 2" PVC CHASE ( o � FS 2856 2856 SPF#2 Z l TO 2ND FLR. N = J o N .-. La O r. q c`h ;' . e:; d • • SHIPL I p m vi tY L r Trf;eS_.. 25'- 8 1/4" SHEATHIN 6[-4 1/2" 19'-6 1 /4" I ' � m I¢- rN C; N o \ I o 30 I I I I oo I m UJ I_ � �' � N z N M M LANDING L-- wJ L° -- J a I c~ -n i; Z e U) 8 CD � 7 1 " MUSTEE 10 n 6 ° SPF 2 6 I Z�¢= o U SP in d F-1" UTILITY SINK - N Wj Lnn o f (3 Room Sq Ft: 311.9 N I r--------- --� \ I z o rn a Z U Dp 10 30-31004 20 `0 SUN ROOM Light Req: 24.95 LIVING ROOM m \ m To I (DOUBLE TOP PLATES) I 1 � J � � ¢ a - W Z r- - ° � DIo Light Provided: 52.94 N N L ------------J op O 1 < C-4 In p N- N m vent Req t2.4s 0° 5-2 3/4" LAUNDRY i� o N o a^o N L'i w o M W Vent Provided: 34.93 -'r 2856 I Z z F- = 0 = ,n z Combined light & vent for Sun Room & Living Room w " o (5)-2x6 I ¢ 0 4. N rn W w _j j o " > 3'-0 3'-0" ; PFS SPF/2 - U �� ¢ o d CL ME w DO U S S N 1 5'-0" S-2 1/4" MQ o CLO LABEL N Of cn w 25} a Z r7 <I I _I Z-31 2" \O I CR �WWQm W = u,o N i2 z� I I a 4'-10 1/4" 0 I = I- a- CL 41 � H i i � o 'd - HD : 3-2x6 ¢¢ c QI SHIPLOOSE'I 1 m� N w o�- m � � o -- '-10 1/4" K SHEATHING -o I N N M p J w z Vie 9'-61/4" t -. o FO ER OMIT 13'-2 1/16" ❑I (5)-2x6 FS i z Uj o *TE PERED S o F 2 I¢ o a > F w ao SP 2856 I J I (7)-2x6 FS (3)-2x4 IS \ I iD N I ~ v a Of En Q }- 2'_6^ v5 I SPF1E2 SPF/2 I I - I�� tY c� z ,,, " g m I------------------S-15i1 -I OMI 15'-1 3/16" FOYER 3/ "' I o o� o o a z 0O Q i' 2 B 21'-10 1 1 I 0 1 CJ f- O- ~' o 0 OMIT S-11" SECT Q v� o m v N CLG & WALL GYP - - - 2x6 5'-0" 3'-0" 5\ BLDR. REQ.° (4)-2x6 FS w m c z X �� 13' 1 3'-0" � �� 10'-11 1 2 SPFf2 L1J O N = ¢ "pp0 i< z I Z (2)-2x6 U189624 J " O I - SPF/2 - (2)-2x6 FS - - - - - - - - - - - - - - (4)BTK18 ' _ SHIPLOO E _ LL I J _ _ -3 1 ]1 SPF/2 SHEATHI G I POR H \_ *TEMPERE * W" HIGH W L _9 F -t 1 11 Nf 1 BATH #1 � HASE 36'-0" \ W � o o SP W/1 " BARTOP 2" PVC CHASE II s I TO 2ND CFLIR. ° o � O I Q 2456 a6 1/2" A.F.F. _ �{ �� TO 2ND FLR. III I N I I r In I m r------------� s i I Q a \, N KITCHEN I� --J c"v " DR & � (DOUBLE TOP PLATES) J c,7 d ¢ r- I TEMPERED DINING ROOM � m I N 2-3 4' SUPP. I �, o o w SP SN -13278 2v o ; FROM 2nd STORY BEDROOM #1 O oo a- W = Room Sq Ft: 123.46 I (/ "' "' S eD H ¢ COUNTERTOP ON-SITE BY OTHERS ^ m z ® J U I-- DHP 1056 I Light Req: 9.86 d 2856-2 d m c O f.� Light Provided: 53.23 BK243015 - 2'-6" q I N � Room S Ft: 129.17 Q O > CD Vent Req: 4.94 2" FUTURE VENT Iq; j ' RE5 36S Light Req: 10.33 N _j 5 m Vent Provided: 13.81 TOE KICK iiia c iA Vent Req: 23 5.17 W H o, ( 3" RADON VENT ilt 3 i 4' 1" Vent Provided: 11.6 5 -2x6 FS z I z m N M OMIT' '\� IS --U 6 SPF/2 cii J a¢ a z 1 Of 0 *TEMPERE * 2' DRAIN o OMIT SINK & FAUCET "' N N N H _3 it > z z czD F- l`_ Ld = o $P FROM 2nd STORY 13'-0 co °O N o ~ o > I'- D_ > > a o O��w i 2456 - WALK-IN N w Q��ao: 1 = O _J rn T KICK r�-UTK22 _, CLOSET O SHIPL�00 E o- o I U ¢ wCA12 GW x o BD27-4D DWS I ( 1 ( 11 824 F- I t I I I ti1�~ 3" DRAIN 10'-11 1/2" SHEATHI G d O0 Z 8-11 3/4" W3642 I [ _l 1� 11 W21 �! FROM 2nd STORY (4)-2x6 FS m = F I ----= =J •. SIR z cnNNmFIn¢¢ Q = 2U U�¢z �1RUCTURAL POST. TYP.16'-2" 0-1 _jz DATA PLATE, STATE LABEL SP " SIDING OMIT S.Q. v 2-6 O AND PFS LABEL LOCATION 911pL00SE HDR: 3 22'-11 1/4 SHINGLES 16 1/3 S. Q. -2x6 PLUM6 HIP & RIDGE 2 PKS. � p SPF #2 HDR: 3-2x6 a SPF #2 40'-0" TRUSS B- � N M � o n n O p S BY PBS- I_ N co N N ^ r� 48'-0" RIDGE VENT -6 0 N O 1 M to N '� — 0 NATHANA 9/26/2013 7: 31: 43 AM - N o m NOTES: 1. *-DENOTES ADDITIONAL COLUMN IN BASEMENT 5. STAIRS TO BE 81/4" RISERS AND 9" TREADS. 2. 2X6 EXTERIOR WALLS 16" O.C. 6. CLG GIRDER ABOVE DIN RM/LIV RM TO BE: /4 1 Vr X 91/4" ML CODES: THIS PRINT HAS BEEN EXTRACTED FROM A �i l SET OF A PREVIOUSLY APPROVED SYSTEM OR JI 3. 2X4 MARRIAGE WALLS 16" O.C. 7. HEAT LOSS WAS CALCULATED W/ R-19 INSULATION OR HEATED BSMT 2010 RESIDENTIAL CODE OF NEW YORK STATE A MODEL APPROVAL AND Is ON FILE %ATH STATE 2008 NATIONAL ELECTRICAL CODE AND IS OK TO BE BUILT a 4. 9 -0 CLG: 1ST FLR. ONL n. 8. BUILDER IS RESPONSIBLE FOR PROVIDING A PROPERLY ( SIZED HEATING SYSTEM TO COVER A BTU LOSS OF 61600 ENERGY CONSERVATION CONSTRUCTION CODE OF NYS - 2010 EDITION x �. Ur=v.�r___.., a SCDHS Ref.# RIO -12-0018 TEST BORING 41 6y McDonald Geosclence'qA 7/21110 EL 16 5 R sr Fp O, a 0.5' 3' 15.8 17' Dark Brown Loam OL Brown Slit ML Brown Silty Sand with 10% Grovel SM Brown line to Coarse Sand SW Water In Brown Fine to Coarse Sand SW . The locations of wells and cesspools •qo�� S,S, shown hereon are from field observations 6' and or from data obtained from others. Therefore their locations and or existence Ss� sC,� FST is not guaranteed. O S- �� �00 OO„ O 1 40, EL.7'°•, 48) R'• � ,� o T �' o/ OR H R O Q y P C2 h �(0 J �. PR66OSED SEPTIC SYSTEM �, x\00 QQ` • .4w (4 BEDROOMSI �� �'a°d� Y . s' ,a �o 1 - 1000 GAL. PRECAST SEPTIC TANK ��,�•�IQ� I- LEACHING POOL 8'0 x 12' DEEP WITH ? `' 3' SAND COLLAR (SWI BOTTOM -TO BE 3' ABOVE GROUND WATER PROPOSED DWELLING TO DISCONNECT °`00,F ' QJ O. '`ab FROM EXISTING SEP79C SYSTEM � ,M �'�• � Of,� INt 5 s . 0 a, EXISTING HO#3SE NOT SHOWNHEREON��VP " 0- 4h TO BE REMOVED o _ O , • s' ! AUG $ r( ! RAIN RUNOFF CONTAWMENT �'a 1145 s f., try °• � ,��. '`}p• B�j '9lpA, eK '/ X a17 . 195 At NP OSE D* 6'0 x 5` ds , HOUSE 4F Fin. Fir. @1 18.5 A� EL. ! 7.9 Fin. Grad `Vp� ti EL 17.4 CJ00,p. IE 16.3. 1. 1, rE ST „Rz 16.0 13.51E 15.4 �p e• . Lp (` V EL 3.9 GROUND WATER EL 0.7 "pua ExpeeNa 3• kft (-V 6% SEPTIC SYSTEM CROSSECTION- �h� ', \ 0 �� �v NO SCALEOct s. Q `o ,t o , o°�Q� SURVEY -OF PROPERTIES ,o o. 'AT AR. SHAMOMOQUE TOWN OF SOU THOLD SUFFOLK COUNTY, N. Y \ f �< F ®� B SEPTIC SYSTEM MEASUREMENTS 1000 — 52 - 02 — 34 sT° 2r I r 1000 - 52 -03 - 11 LP Scale:1" - 30' �` s �g. Aug.' .18; 010 TAug. 31,' ZOf (cesspools) O. • / 30 SepT. l4, 2fiiiJl (PIOp' H015E) Feb.15, 201 (rev/slonsl y'4/Lf March /3, 201?. (revisions) Aprll 2 20j2 (revs/onsJ Apra l�, 2 2(re s May /5, 20/2 (isvlt/onsJ �' • = L�4 TH,OO� .June 211 2012 (addition) Oct. •7, 2013 (foundation) v m WETLAAVS FLAG MAW 23, 2014 (final) LANDWARD EDGE OF TIDAL WETLANDS AS DELINEATED BY SUFFOLK ENVIRONMENTAL CONSUL TING, INC. AUGUST 8, 2011 I I am 'familiar with the STANDARDS FOR APPROVAL AND CONSTRUCTION OF SUBSURFACE SEWAGE DISPOSAL SYSTEMS FOR gINGLE FAMILY RESIDENCES and will abide by /tie conditions set forth therein and on the permit to construct. 4U 5� FLOOD ZONES FROM FIRM 36103CO158H ANY ALTERATION OR ADDITION TO THIS SURVEY 1S A VIOLATION .'' lC. hf0.49618 OF SECTION 7209 OF THE NEW YORK STATE EDUCATION LAW. EXCEPT AS PER SECTION 7209 -SUBDIVISION 2. ALL CERTIFICATIONSPECON/C S , P. C. HEREON ARE VALID FOR THIS MAP AND COPIES THEREOF ONLY IF SAID MAP OR COPIES BEAR THE IMPRESSED SEAL OF THE (631) 765-5020 FAX 765-1797 SURVEYOR WHOSE SIGNATURE APPEARS HEREON. P.O. BOX 909 10-186 O _/ C7p6 1230 TRA VEL ER S TREET ELEVATIONS ARE REFERENCED TO NA VD 88 SOUTHOLD, N. Y. 11971/0-/87 NUT, ,�. �a oy oy _ 0 4w V PRnPOSED SEPTIC SYSTEM' ''moo, �/C .00 ,� 0 .00 Iry 14 BEDROOMSJ .,a�; �, \� Q'. yah �• Q " 1 - 1000 GAL. PRECAST SEPTIC TANK I- LEACHING POOL 8'0 x 12' DEEP WITH 3' SAND COLLAR ISWJ BOTTOM -TO BE CO' 3' ABOVE GROUND WATER PROPOSED DWELLING TO DISCONNECT-° Q� �'sO�r SAO �T. FROM EXISTING SEPTIC SYSTEM '`fib SO ~0O \ NOT SHOWN. TO BE REMOVEDHEREON Q RAW RUNOFF C 0 1• I '' io MOUSE STT i1.. •� � x.� f95 �lf Qj � -1145 PROVIDE P DW#' 6'f Jr 51 deep,.'` sr b ^j� HOUSE �� • �' Fin. FM. N I" E1.17 9 Fk 6x4& �! 1+ i 446. _ V• ''JE leirs sr 14yy 1�,d� `�'� �`.' '�• �' fid' LIQ b GROIJM!? MATER Q 0.7 91 p,�+`� �Q1b 40,4• '� � SEPTIC SYSTEM Q` '� 5 NO SCALE 4`0N0� :P oo /,I0 O�SURVEY-OFPRO av A T , * \o` AR. SHAMOMC .,�Q vas C3*TOWN OF SOU SUFFOLK COUti ®4 SEPTIC SYSTEM MEASUREMENTS rOOO - 52 - 02 of ST ' 2r lr •1000 - 52'-03 LP , Scale: 1" ^ 3( Agg." 18,. 20 ,3O „ Aug�. 31,'20/ l a,41 •4�s� / F p.114, ell ueRlsk d' 'Q March /4 21019 (rev, t �D�q Ap � 2� 2Af2P trerl4o pF Mp /5,'20V2 fnr/s/o, A' LATHAO� .lune 21, 2012 laddltic aati O Oct. , 2013 (tound v WETLAWS FLAG MANY 23, 2014 !final LANDWARD EDGE OF TIDAL WETLANDS AS DELIt+IEATEO BY SUFFOLK ENVIRONMENTAL CONSUL TING, WC, AUGUST B, 2011 I am familiar with the STANDARDS FOR APPROVAL' E� AND CONSTRUCTION OF SUBSURFACE SEWAGE ; `� DISPOSAL SYSTEMS FOR SINGLE FAMILY RESIDENCES and will abide by /tie conditions set forth therein and on the permit to construct. A,JG 1 8 7014` FLOOD ZONES FROM FIRM- 36103C0/58H ANY AL TERA TION OR ADDITION TO THIS SURVEY IS A VIOLATION OF SECTION 7209 OF THE NEW YORK, STATE EDUCATION LAWS