Loading...
HomeMy WebLinkAbout39365-Zlen CERTIFICATE OF OCCUPANCY 2/3/2015 37409 Date: 2/3/2015 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 450 Bittersweet Ln, Cutchogue, SCTM #: 473889 See/Block/Lot: 104.-2-7.3 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 11/13/2014 pursuant to which Building Permit No. 39365 dated 11/14/2014 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: ROOF MOUNTED SOLAR PANELS TO AN EXISTING ONE FAMILY DWELLING AS APPLIED FOR The certificate is issued to Geraci, Stephen (OWNER) of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 39365 01-06-2015 PLUMBERS CERTIFICATION DATED Authorized Signature Town of Southold P.O. Box 1179 53095 Main Rd Southold, New York 11971 631-765-1981 len CERTIFICATE OF OCCUPANCY 2/3/2015 37409 Date: 2/3/2015 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 450 Bittersweet Ln, Cutchogue, SCTM #: 473889 See/Block/Lot: 104.-2-7.3 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 11/13/2014 pursuant to which Building Permit No. 39365 dated 11/14/2014 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: ROOF MOUNTED SOLAR PANELS TO AN EXISTING ONE FAMILY DWELLING AS APPLIED FOR The certificate is issued to Geraci, Stephen (OWNER) of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 39365 01-06-2015 PLUMBERS CERTIFICATION DATED Authorized Signature No: 4 Town of Southold P.O. Box 1179 53095 Main Rd Southold, New York 11971 631-765-1981 CERTIFICATE OF OCCUPANCY 37410 Date: THIS CERTIFIES that the building SOLAR PANEL Location of Property: 450 Bittersweet Ln, Cutchogue, 2/3/2015 2/3/2015 SCTM #: 473889 Sec/Block/Lot: 104.-2-7.3 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 11/13/2014 pursuant to which Building Permit No. 39365 dated 11/14/2014 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: ROOF MOUNTED SOLAR PANELS TO AN EXISTING ACCESSORY GARAGE AS APPLIED FOR The certificate is issued to Geraci, Stephen (OWNER) of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 39365 PLUMBERS CERTIFICATION DATED 01-06-2015 Authorized Signature Permit #: 39365 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permission is hereby granted to: Geraci, Stephen 450 Bittersweet Ln Cutchoaue. NY 11935 To: install roof mounted (two) Solar Panel systems as applied for At premises located at: 450 Bittersweet Ln SCTM # 473889 Sec/Block/Lot # 104.-2-7.3 Date: 11/14/2014 Pursuant to application dated 11/13/2014 and approved by the Building Inspector. To expire on 5/15/2016. Fees: SOLAR PANELS SOLAR PANELS CO - ALTERATION TO DWELLING CO - ACCESSORY BUILDING Total: f� Building Inspector 11 $50.00 $50.00 $50.00 $50.00 $200.00 Form No. 6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings, property lines, streets, and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage -disposal (S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead. 5. Commercial building, industrial building, multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of cgmpleted site plan requirements. B. For existing buildings (prior to April 9, 1957) non -conforming uses, or buildings and "pre-existing" land uses: 1. Accurate survey of property showing all property lines, streets, building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied, the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy - New dwelling $50.00, Additions to dwelling $50.00, Alterations to dwelling $50.00, Swimming pool $50.00, Accessory building $50.00, Additions to accessory building $50.00, Businesses $50.00. 2. Certificate of Occupancy on Pre-existing Building - $100.00 3. Copy of Certificate of Occupancy - $.25 4. Updated Certificate of Occupancy - $50.00 5. Temporary Certificate of Occupancy - Residential $15.00, Commercial $15.00 Date. New Construction: Old or Pre �-existing Building: (check one) Location of Property: 1� J 'j'f e ���Q �. L House No. Street Hamlet Owner or Owners of Property: Suffolk County Tax Map No 1000, Section 104 Block Lot Subdivision (,, ' I + Filed Map. Lot: Permit No. "� Date of Permit. t, `1 `� Applicant:�((� I(�•1/�1 {�� Health Dept. Approval: Planning Board Approval: Request for: Temporary Certificate Fee Submitted: $ Underwriters Approval: Final Certificate: (check one) ,2 (Dlkaiv�� App icant Signature Town Hall Annex 54375 Main Road P.O. Box 1179 Southold, NY 11971-0959 kpF SO�jyo� CIO 40UNITI,� Telephone (631) 765-1802 Fax (631) 765-9502 roger. riche rt(a-town.southoId. ny.us BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION Issued To: Stephen Geraci Address: 450 Bittersweet Ln City: Cutchogue St: NY Zip: 11935 Building Permit #: 39365 Section: 104 Block: 2 Lot: 7.3 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: Eastern Energy Systems License No: 52689 -me SITE DETAILS Office Use Only Residential X Indoor Basement Service Only Commerical Outdoor X 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures HID Fixtures Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Fluorescent Fixture Pumps Transformer Appliances Dryer Recpt Emergency FixtureSIA Time Clocks Disconnect Switches Twist Lock El Exit Fixtures TVSS Other Equipment: 12.65 Watt roof mounted PHOTOVOLTAIC SYSTEM to include, 46-LG275 watt panels, 2 -Sunny Boy 4000, and 1 -Sunny Boy3000 inverters, 2 -ac disconnects, 2 -PV meters Notes: Inspector Signature: Date: Jan 6 2015 81 -Cert Electrical Compliance Form.xls 0-1 O��pf SOUIyo V �o • ioQ TOWN 07 SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION IST [ ] FOUNDATION 2ND [ ] FRAMING/ STRAPPING [ ] FIREPLACE & CHIMNEY [ ] FIRE RESISTANT CONSTRUCTION [ ] ELECTRICAL (ROUGH) [ ] CODE VIOLATION REMARKS: [ ] ROUGH PLUMBING [ ] INSULATION [ ] FINAL [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT PENETRATION �ELECiRICAL (FINAL) [ ]CAULKING DATE j � � �' INSPECTOR LUIGI CLAUDIO SCIANDRA, P.E. 5 Wesleyan Court - Smithtown, NY 11787-3011 • (631) 543-2953 • fax (631) 543-1526 Cell. 631-747-7495 E-mail: Ics4dftaol.com Saturday, January 17 Town of Southold Building Department 54375 Main Road P.O. Box 1179 Southold, NY 11971-0959 Re: Certification Letter - Forty Six (46) 275 W P. V. Roof Top Solar Panel Array, 12.65 kW Total Output, for Geraci Residence — 450 Bittersweet Lane Cutchogue, New York 11935 I have reviewed the solar energy system installation in the subject topic. The units have been installed in accordance with the manufacturer's installation instructions and the construction drawings approved by the Town of Southold. The solar panel installation is in compliance with the requirements of the 2010 Residential Code of New York State, ASCE-05 and N. F. P. A. Standard 70 "The National Electrical Code." Markings in accordance with Section 690.53 of the National Electrical Code are provided. To my best belief and knowledge, the work in this document is accurate, conforms with the governing codes and standards applicable at the time of submission, conforms with reasonable standards of practice with the view to the safeguarding of life, health, property and public welfare. Sincerely, i Claudio Scian", P. E. of NEW yo y� JAG\ C. SCIAt., 'i v "4 SAO 060935-1 ARCFESSIO FOUNDATION (1ST) FOUNDATION (ZND) ROUGH FR4n2tNQ & PLUMBING INSULATION PER N. Y. STATE ENERGY CODE FINAL "OWNF SOUTHOLD BUILDING DEPARTMENT TOWN HALL SOUTHOLD, NY 11971 TEL: (631) 765-1802 FAX: (631) 765-9502 SoutholdTown.NorthFork.net PERMIT NO. Examined 1/111 20 BUILDING PERMIT APPLICATION CHECKLIST W !,� Q (.1A, Fes`' Do you have or need the following, before applying? Board of Health 4 sets of Building Plans_ Planning Board approval Survey Septic Form N.Y.S.D.E.C. Trustees C.O. Application Flood Permit Single & Separate Storm -Water Assessment Form Contact: Approved `' i� _, �� , li ` lam: 60 r„Ur►40 L Disapproved a/c N011 13 2014 62!647 Phone: r T. Expiration 20 ri ' Building Inspector APPLICATION FOR BUILDING PERMIT Date gll9 INSTRUCTIONS 20 1Y a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans, accurate plot plan to scale. Fee according to schedule. b. Plot plan showing location of lot and of buildings on premises, relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application, the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e. No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim, the Building Inspector may authorize, in writing, the extension of the permit for an addition six months. Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County, New York, and other applicable Laws, Ordinances or Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances, building code, housing code, and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. /4VW 3&A, ra_4� 6�n_y Signature of applicant or name, if a corporation) 7y-70 !Wd Avg, 1V1,1Ikkc,4 MZ r19�;z (Mailing address of applicant) State whether applicant is owner, lessee gent rchitect, engineer, general contractor, electrician, plumber or builder Ca!�fem Ctwav � wlw" - Name of owner of premises I (As on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer (Name and title of corporate officer) Builders License No. q:�?�gq H Plumbers License No. Electricians License No. M_lm, Other Trade's License No. 1. Locatiou of land on which House Number Street done: /V Hamlet County Tax Map No. 1000 Section 104 Block a Lot 13 1"W" Subdivision Filed Map No. Lot 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy b. Intended use and occupancy Nature of work (check which applicable): New Buildi Repair Removal Demolition 4. Estimated Cost 5. If dwelling, number of dwelling units If garage, number of cars Other Work Fee Alteration (Description) (To be paid on filing this application) Number of dwelling units on each floor 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of existing structures, if any: Front Height Number of Stories, Rear Depth Dimensions of same structure with alterations or additions: Front Rear Depth Height Number of Stories Dimensions of entire new construction: Front Rear Depth Height Number of Stories 9. Size of lot: Rear Depth 10. Date of Purchase Name of Former Owner 11. Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law, ordinance or regulation? YES NO V 13. Will lot be re -graded? YES NO Will excess fill be removed from premises? YES NO 14 X150 PjitW-(Mee+ "Ie Names of Owner of premises *egikn %L(aCl Address Crri 2UA, NJ 119 Phone No Name of Architect Address Phone No Name of Contractor Address Phone No. 6_61 7-N Asa 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NOy * IF YES, SOUTHOLD TOWN TRUSTEES & D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO V * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey, to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. 18. Are there any covenants and restrictions with respect to this property? * YES NO ✓ * IF YES, PROVIDE A COPY. STATE OF NEW YORK) COUNTY OFSUkA S iW_�' L�Q7(U'1 4 ' being duly sworn, deposes and says that (s)he is the applicant (Name of individual signing contract) abo e n med, (S)He is the Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be performed in the manner set forth in the application filed therewith. SwN t before me t44iAA 11)19 l �, of 20 NoKIRSTENry IE�. HE S Notary Public, State of New York No. 01 HE61 74810 Qualified in Suffolk County Commission Expires 09/24/20 � Signature of Applicant Town Hall Annex 54375 Main Road P.O. Box 1179 Southold, NY 11971-0959 Telephone (631) 765-1802 roaer.dchertdro,w(n so6u` go9o.ny.us BUILDING DEPARTMENT TOWN OF SOUTHOLD APPLICATION FOR ELECTRICAL INSPECTION REQUESTED BY- &V6e t 6Mj[5,- Date: Company Name: ' em r%I oy. j= ( -b Name: MIOII LK - License No.: 6X$q-/n6 No.. JOBSITE INFORMATION: (*Indicates required information) *Name: *Address: *Cross Street: *Phone No.: Permit No.: Tax -Map District: 1000 Section: 104 Block: 9, Lot: 7'?j *BRIEF DESCRIPTION OF WORK (Please Print Clearly) 6&-27 J&4j jQ(. 12.65 WaH f hr N Ocj 46 LG a-7, wa 4- Q sXMIM, U! ryl �1, �;M A 5una q % iq ±GboZ L 5 ver+ex- (Please Circle All That Apply) *Is job ready for inspection: Rough In Final *Do you need a Temp Certificate: NO Temp Information (If needed) *Service Size: �I�Phase 3Phase 10 *New Service: Underground Additional Information: 0 150 200 300 350 400 Other Number of Meters Change of Service Overhead PAYMENT DUE WITH APPLICATION 82 -Request for Inspection Foran fzt C, Scott A. Russell SUPERVISOR w SOUTIIOLD TOWN IiALL- P. U. Box 1179 p 53095 Main Road - $UU'nIOLD, ra-W YORK 11971 S�r(0)1R \\4[ vA�7r1EJR, MANAGIEACENT Town of Southold CHAPTER 236 - STORMWATER MANAGEMENT WORK SHEET ( TO BE COMPLETED BY THE APPLICANT) DOES 'x,HIIS PROJECT INVOLVE ANY OI- THE FOLLOWING - (CHECK ALL THAT APPLY) A. Clearing, grubbing, grading or stripping of land which affects more than 5,000 square feet of ground surface. B. Excavation or filling involving more than 200 cubic yards of material within any parcel or any contiguous area. 100 feet of horizontal distance. ❑d D. Site preparation within 100 feet of wetlands, beach, bluff or coastal erosion hazard area_ [�[ E. Site preparation within the one -hundred -year floodplain as depicted on FIRM Map of any watercourse. ❑[7j F. Installation of new or resurfaced impervious surfaces of 1,000 square feet or more, unless prior approval of a Stormwater Management Control Plan was received by the Town and the proposal includes in-kind replacement of impervious surfaces. If you answered NO to all of the questions above, STOP! Complete the Applicant section below with your Name, signature, Contact Information, Date & County Tax Map Number Chapter 236 does not apply to your project. If you answered YES to one or more of the above, please submit Two copies of a Stormwater Management Control Plan and a completed Check List Form to the Building Department wlt F-yoour Building Permit Application. S.C:.T.M. *: 1000 Date. APPLICAN71 (Property Owner. Deyyign Profmio , A„eni "ontrictor, Other) pullict NAME /10 1'L i.W/� !% S HloCk l �,� j Teva /1 .01 Contact InFormatron' 9 Aap4we Nud:!<ri Property /Address / Location of Construction Work: FORM ' SMCP -'1"OS MAY 2014 ":'• I"Uh Litlil_1)li\t; IX':;1 I'1 TN`11:*'N I Reviewed By. 5)p _ Date: �lvl Apprnved for processing Building Permit. Stormwater Management Control Plan Not Required. El—-Storrnwater Maittegcrrtcnt Control Plan rs Required. (Forward to Engineering Department for Revicw,) L A # 0OZ999b 6E ZI'�1-66-60 Town Hall Annex 54375 Main Road P.O. Box 1179 Southold, NY 11971-0959 January 9, 2015 Eastern Energy Systems 7470 Sound Ave Mattituck NY 11952 BUILDING DEPARTMENT TOWN OF SOUTHOLD Re: Geraci, 450 Bittersweet Lane, Cutchogue TO WHOM IT MAY CONCERN: Telephone (631) 765-1802 Fax (631) 765-9502 The Following Items (if Checked) Are Needed To Complete Your Certificate of Occupancy: "NOTE: Certification is required from an engineer stating the panels were fastened to the roof per NYS Building Code V1 Application for Certificate of Occupancy. (Enclosed) Electrical Underwriters Certificate. A fee of $50.00. Final Health Department Approval. Plumbers Solder Certificate. (AII permits involving plumbing after 4/1/84) Trustees Certificate of Compliance. (Town Trustees # 765-1892) Final Planning Board Approval. (Planning # 765-1938) Final Fire Inspection from Fire Marshall. Final Landmark Preservation approval. Final inspection by Building Dept. Final Storm Water Runoff Approval from Town Engineer BUILDING PERMIT — 39365 - Solar Panels BITTERSWEET LANE Dl - 4 S �If FOR SCDHS USE ONLY W 0 0 30' WIDE N 66'22'50"E 183.36' 1 w r/E 1 11 r f _ 304.02, Ix 3 K I� �SB \ 2F I N _ i 0i O a / � On m � ~ O I i i RESIDENCE f0''Iy rmT1 TD Cp o z WOOD FRAME a W 0 ' RESIDENCE 0 o k 0 WW Y y� �u.o, 1 IL �b RESIDENCE TEST HOLE BY R \\ McDONALD GEOSCIENCE 0 W K p 1 p IX \ORIGINAL \ I SOUTHOLD. NY ON JULY 13,1999 GROUND _ PoEE 5.5' —DI I- Fl ' Dl - 4 S �If FOR SCDHS USE ONLY W 0 0 0 q i 1 w r u1 0 s V I Ix 3 K �SB SCDHS# R10-0. GUARANTEED TO: STFPHFN CFRAfI r GUARANTEES /NDICATED HERE ON SHAII RUN L. ", TU THE L'ERSM FOR WN w SU.RKY /S PREPARED, AND ON MS BE ALF TO THE B TIRE CC -Y,, WwRNYENTAL AGENCY, LENDING INSTIMVP .. IF LISTED IIEREON, AND TO ME ASSIGNEES OF THE LCNON MSBiUBCW. WARANrCS ARE NOT TRANSFERABLE TO ADMRONAL MST,TLTIONS OR S0BSFW6NT 0WITS UNAUTNORIZC0 ALTERATIG/ OR AOOIIM TO TNI$ SU9Wr IS A WOLANO.N .'A` SLC RCN 7.'O9 DF M[ NEW YORK STATE FINICATI&i IAW. COPIES � IWS SLII?W1 YAP NOT BEARING TME LANG SUR✓E✓CWS EMBOSSLO SEAL SHALL NOT BC 1pI1—CO TO RE A ✓4110 -1E ci— N/F RYAN (VACANT LAND) N L4 Rae BRDWN NNE TO 0 RESIDENCE COARsE SANG SW SURVEY OF LOT 2 IN 3A SU13DMSON MAP FOR MABELLE DEMPEWOLF SITUATE CUTCHOGUE, TOWN OF SOUTHOLD SUFFOLK COUNTY, N.Y. SURVEYED FOR: STEPHEN GERACI TM# 1000-104-02-007.3 NOTE: THIS LOT WILL BE SHOWN IN A MINOR SUHONISION WITH LOT NUMBERS SPEOFICALLY PREPARED FOR THE SUFFOLK COUNTY DEPT. OF HEALTH SERVICES. ON THIS MAP, IT WILL BE SHOWN AS LOT #2. SCDHS APPLICATION NUMBER S10-98-0009 2. 29 II4E 01 LOCATE — ANO GARMA TCUNMTKWS. 2 11. W S W IN —E AND GARAGE. iTT-1 OW �Of�TpN. SURVEYED 7 DECEMBER 2005 SCALE 1"= 40' AREA - 41,872 S.F. CP 0.961 ACNLS SURVEYED BY STANLEY J. !SAKSEN, ;K. P.O. BOX 294 NEW S FOLK. N.Y. 11956 631-7 -5835 ENS L VEYOR JYS Li No. 49 13 J5R1458 CONSENT TO INSPECTION 5 "eko efaa) , the undersigned, do(es) hereby state: Owner(s) Name(s) That the undersigned s) (are) the owner(s) of the premises in the Town of Southold, located a(�)-PD5pe- k)y 11935 which is shown and designated on the Suffolk County Tax Map as District 1000, Section , Block , Lot That the undersigned (has) (have) filed, or cause to be filed, an application in the l¢ Town Binding Inspector's Office for the following: &,de�al 60&( That the undersigned do(es) hereby give consent to the Building Inspectors of the Town of Southold to enter upon the above described property, including any and all buildings located thereon, to conduct such inspections as they may deem necessary with respect to the aforesaid application, including inspections to determine that said premises comply with all of the laws, ordinances, rules and regulations of the Town of Southold. The undersigned, in consenting to such inspections, do(es) so with the knowledge and understanding that any information obtained in the conduct of such inspections may be used in subsequent prosecutions for violations of the laws, ordinances, rules or regulations of the Town of Southold. Dated: gjjgji4 (Signature) (Print Name) WGI CLAUDIO SCIANDRA, P.E. 5 Wesleyan Court • Smithtown, NY 11787-3011 • (631) 543-2953 • fax (631) 543-1526 E-mail: Ics4d aol.com''}° _ APPS �VED AS ��U I Cs Saturday, November 08, 2014 DATE f l i l'f R." #. _ i_ate_, Eastern Energy Systems F _ E Y 4-IZZ-1 7470 Sound AvenueNOTIFY UILDIrJG DEPARTMENT , Mattituck, New York 11962 765-1802 8 AM TO 4 PM FOR TF; FOLLOWING INSPECTIONS: Tel. 631-779-4004 1. FOUNDATION - TWO REQUIRED Attn.: Mr. Mike Lawton FOR POURED CONCRETE Engineer/Project Manager 2 ROUGH FRAPELE I.!i��iB!NG, SCRAPPING. ELECTRICAL & CAULKINC' 3. INSULATION Re: Forty Six (46) 275 W P. V. Roof'fObINAL - CONSTRUCTION & ELECTRICAL Solar Panel Array. 12.65 kW Total OutWu BE CC' ON SH FOR EE STi;UCTION SHALL MEET THE Mr. Geraci Residence —450 BittersweiiLi MENTS OF THE CODES OF NEIN CutchOCtue, New York 11935 YORK STATE. NOT RESPONtiISLE FOR DLSIGN OR CONSTRUCTION ERRORS. Dear Mr. Lawton: Pursuant to your request, I have reviewed the following information regarding the subject roof top solar panel array: • Cover Sheet with Site Visit/Verification prepared by E2Sys representative identifying specific site information including size and spacing of rafters for the existing roof structure • Design drawings of the proposed system to include site plan, roof plan, mounting details for the solar panels. This information was prepared by E2Sys and will be utilized for approval by the Town o ff7 and for construction of the proposed system. Based on the above documentation, I have evaluated the structural capacity of the existing system to support the additional loads imposed by the solar panel arrays and offer the following comments: The existing roof type is provided with composite shingles, age less than five (5) years, one (1) layer, 2"x10" Douglas Fir rafters at 16" on center, Y2" thick roof plywood decking with 44 - 44 - 21- 36 roof pitch, 2"x6" ceiling joists at 16" on center. Our review of the photos of the exterior roof indicates no signs of settlement or misalignment caused by overstressed underlying structural members. Structural Analysis: The structural analysis has been carried out using the following design criteria: Design wind speed (3 sec. gust): 120 mph Ground snow load: 20 lbs/sq. ft. Solar Array Dead Load: 2.6 lbs/sq. ft. Total Weight of Array: 2168.4 lbs Point Load: 25 lbs The above values are within acceptable limits of recognized industry standards for similar structures. The structural analysis performed for the existing structure and for the solar panel arrays, utilizing the above design loads, indicates that the existing roof rafters will be able to supports the additional panel weight without damage, if installed correctly. The onsite inspection and the photographs show that the roof framing is in good conditions. However, the dwelling owners are to be made aware that long term build up of heavy snow conditions may produce deflections in the roof structure. If any deflection is noticed, than it is recommended that the solar panels be cleared of accumulated snow more than one (1) foot deep over a period of one week. If no deflections are visible under any snow loading over a period of time, then there is no need to clear the solar panels. Based on the above evaluation, it is the opinion of the undersigned professional engineer, that with appropriate solar panel anchors being utilized, the roof system will adequately support the additional loading imposed by the solar panel arrays. This evaluation is in conformance with the 2010 Residential Code of New York State, the 2001 Wood Frame construction Manual, SEI/ASCE 7 "Minimum Design Loads for Buildings and Other Structures", current industry standards and practice and based on documentation and data supplied by E2Sys at the time of this report. Should you have any questions regarding the above or if you require additional information, do not hesitate to contact me. Sincerely, Luigi Claudio Sciandra, P. E. OF NEW YO y� JAG` c. scl qtv, 'f v '9 SAO 060935'1 AROFEssloNP, 2 SCOPE OF WORK TO INSTALL A 12.65 KW SOLAR PHOTOVOLTAIC (PV) SYSTEM AT THE GERACI RESIDENCE, LOCATED AT 450 BITTERSWEET LANE IN CUTCHOGUE, NY. THE POWER GENERATED BY THE PV SYSTEM WILL BE INTERCONNECTED WITH THE UTILITY GRID THROUGH THE EXISTING ELECTRICAL SERVICE EQUIPMENT. THE PV SYSTEM DOES NOT INCLUDE STORAGE BATTERIES. SYSTEM RATING 12.65 kW DC STC 11.45 kW DC PTC 11.05 kW CEC-AC EQUIPMENT SUMMARY 4C. LG 275 -NIC G3 PV MODULES 4G ENPHASE M215 PV MICRO -INVERTERS) - IRONRIDGE XRS1000 MOUNTING SYSTEM SHEET INDEX PV -1 COVER PV -2 SITE MAP & PV LAYOUT PV -2.1 ROOF A LAYOUT PV -3 ELECTRICAL 3 -LINE DIAGRAM PV -4 MOUNTING DETAIL & STRUCTURAL LOAD CALCULATIONS GOVERNING CODES 2011 NATIONAL ELECTRICAL CODE 2010 RESIDENTIAL CODE OF NEW YORK STATE UNDERWRITERS LABORATORIES (UL) STANDARDS OSHA 29 CFR 1910.269 SECTION: 104 BLOCK: 2 LOT: 7.3 PROJECT � %.W I I%J114 AERIAL VIEW DESIGN 6 DRAFTING BY: JAMIE MINNICK NASCEP CERTIFIED 051112-129 REVISIONS DESCRIPTION DATE REV ORIGINAL 11-01-2014 A CONTRACTOR SOLAR UNIVERSE 7470 SOUND AVE MATTITUCK'NY 11952 LICENSE # 43839 H PROJECT NAME W Ln wzgrn U Z w�-�. owz w Lu �; LLi Uwo cr w i..._ 0 o Ln U 4d - SHEET NAME COVER SHEET SIZE SHEET NUMBER PV -1 (E) GROUNDING ELECTRODE UTILrrY METER & MAIN SERVICE PANEL ¢ AC DISCONNECT SUNRUN METER COMBINER - INVERTER SOLAR MODULE ATTACHMENT POINT RACKING RAIL RAFTERS 0 16" OF. TYP. L CONSTRUCTION SUMMARY (46) LG 275 NIC -G3 SOLAR MODULES TOTAL, 12.65 kW DC STC (46) ENPHASE M215 MICRO -INVERTER TOTAL, 12.65 kW AC. (86) ATTACHMENT POINTS @ 72" OC MAX. Roof Type = Comp Shingle, Age<5 YRS, # of Layers: 1 Roof Stricture = 2x10 Douglas Fir Rafter @ 16" O.C., %" Plywood Decking Roof/Array #1 - Pitch: 44 - 44 - 21 - 36, Azimuth: 156 / 156 / 156 / 246 CONSTRUCTION NOTES 1.) ALL EQUIPMENT SHALL K INSTALLED IN ACCORDANCE WITH THE MANUFACTURER`S INSTALLATION INSTRUCTIONS. 2.) ALL O0TbOOR EQUIPMENT -SHALL 13E RAINTt`GH_T WITIO MINIMUM NEMA 3R RATING. 3.) ALL LOCATIOMS ARE APPROXIMATE AND, -REQUIRE FIELb VERfFICA-nON. BITTERSWEET LANE IETER INECT DESIGN & DRAFTING BY: JAMIE MINNICK NABCEP CERTIFIED 0 5111 2-12 9 DATE 11-01-2014 CONTRACTOR SOLAR UNIVERSE 7470 SOUND AVE MATTITUCK, NY 11952 LICENSE # 43889 H PROJECT NAME W Lli W Z M U � a) Z WW �- Fn 0 W Z W � W M UWp IX W m p U O Lr)U SHEET NAME PV LAYOUT SHEET SIZE ANSI -B 11" x 17'. SHEET NUMBER PV -2 Yr �I CONSTRUCTION SUMMARY (46) LG 275 NIC -G3 SOLAR MODULES TOTAL, 12.65 kW DC STC (46) ENPHASE M215 MICRO -INVERTER TOTAL, 12.65 kW AC. (86) ATTACHMENT POINTS @ 72" OC MAX. Roof Type = Comp Shingle, Age<5 YRS, # of Layers: 1 Roof Stricture = 2x10 Douglas Fir Rafter @ 16" O.C., %" Plywood Decking Roof/Array #1 - Pitch: 44 - 44 - 21 - 36, Azimuth: 156 / 156 / 156 / 246 CONSTRUCTION NOTES 1.) ALL EQUIPMENT SHALL K INSTALLED IN ACCORDANCE WITH THE MANUFACTURER`S INSTALLATION INSTRUCTIONS. 2.) ALL O0TbOOR EQUIPMENT -SHALL 13E RAINTt`GH_T WITIO MINIMUM NEMA 3R RATING. 3.) ALL LOCATIOMS ARE APPROXIMATE AND, -REQUIRE FIELb VERfFICA-nON. BITTERSWEET LANE IETER INECT DESIGN & DRAFTING BY: JAMIE MINNICK NABCEP CERTIFIED 0 5111 2-12 9 DATE 11-01-2014 CONTRACTOR SOLAR UNIVERSE 7470 SOUND AVE MATTITUCK, NY 11952 LICENSE # 43889 H PROJECT NAME W Lli W Z M U � a) Z WW �- Fn 0 W Z W � W M UWp IX W m p U O Lr)U SHEET NAME PV LAYOUT SHEET SIZE ANSI -B 11" x 17'. SHEET NUMBER PV -2 18' FIRE SETBACK' 0 RIDGES 44° PITCH 44° PITCH e l 0 0 0 i I ID o o o o � 0 0 0 0 0 0 y 0 0 O O D 21° PRCH O OL-1-L-04 O O Q MAX o.�. 3 G• q_7• CONSTRUCTION SUMMARY (46) LG 275 NIC -G3 SOLAR MODULES TOTAL, 12.65 kW DC STC (46) ENPHASE M215 MICRO -INVERTER TOTAL, 12.65 kW AC. (86) ATTACHMENT POINTS @ 72" OC MAX. Roof Type = Comp Shingle, Age<5 YRS, # of Layers: 1 Roof Stricture = 2x10 Douglas Fir Rafter @ 16" O.C., %" Plywood Decking Roof/Array #1 - Pitch: 44 - 44 - 21 - 36, Azimuth: 156 / 156 / 156 / 246 CONSTRUCTION NOTES 1.) ALL EQUIPMENT SHALL K INSTALLED IN ACCORDANCE WITH THE MANUFACTURER`S INSTALLATION INSTRUCTIONS. 2.) ALL O0TbOOR EQUIPMENT -SHALL 13E RAINTt`GH_T WITIO MINIMUM NEMA 3R RATING. 3.) ALL LOCATIOMS ARE APPROXIMATE AND, -REQUIRE FIELb VERfFICA-nON. BITTERSWEET LANE IETER INECT DESIGN & DRAFTING BY: JAMIE MINNICK NABCEP CERTIFIED 0 5111 2-12 9 DATE 11-01-2014 CONTRACTOR SOLAR UNIVERSE 7470 SOUND AVE MATTITUCK, NY 11952 LICENSE # 43889 H PROJECT NAME W Lli W Z M U � a) Z WW �- Fn 0 W Z W � W M UWp IX W m p U O Lr)U SHEET NAME PV LAYOUT SHEET SIZE ANSI -B 11" x 17'. SHEET NUMBER PV -2 CONSTRUCTION SUMMARY - ROOF 1 (46) LG 275 NIC -G3 SOLAR MODULES TOTAL, 12.65 kW DC STC (46) ENPHASE M215 MICRO -INVERTER TOTAL, 12.65 kW AC. J� (86) ATTACHMENT POINTS @ 72" OC MAX. Roof Type = Comp Shingle, Age<5 YRS, # of Layers: 1 Roof Structure = WO Douglas Fir Rafter @ 16" O.C., %2" Plywood Decking Roof/Array #1 - Pitch: 44 - 44 - 21 - 36, Azimuth: 156 / 156 / 156 / 246N�Ey�jt ^ (E) GROUNDIN UTIL MAIN SEI AC SUI S ATTAI RAFTERS @ MAIN HOUSE - A STRING LEGEND STR # = STRING # JB # = JUNCTION BOX # CB # = COMBINER BOX # INV # = INVERTER # 33' 4 p1060935 NI P O-iESS10 zs� GARAGE- B 2 DESIGN & DRAFTING BY: JAMIE MINNICK NABCEP CERTIFIED 051112-129 DATE 11 -01 - CONTRACTOR SOLAR UNIVERSE 7470 SOUND AVE MATTITUCK, NY 11952 LICENSE # 43889 H PROJECT NAME LU Lr) W Z rn Z L!JF- }J 0 WFn Z /y 3LLJ/y/ LLI {.L UWO IX ~ U LU m H O:DiLr)U "It - SHEET NAME ROOF 1 SHEET SIZE ANSI -B 11" x 17" SHEET NUMBER PV -2.1 U H L� O O O O i O Q I D o o p 21 zs� GARAGE- B 2 DESIGN & DRAFTING BY: JAMIE MINNICK NABCEP CERTIFIED 051112-129 DATE 11 -01 - CONTRACTOR SOLAR UNIVERSE 7470 SOUND AVE MATTITUCK, NY 11952 LICENSE # 43889 H PROJECT NAME LU Lr) W Z rn Z L!JF- }J 0 WFn Z /y 3LLJ/y/ LLI {.L UWO IX ~ U LU m H O:DiLr)U "It - SHEET NAME ROOF 1 SHEET SIZE ANSI -B 11" x 17" SHEET NUMBER PV -2.1 LOAD CAL ULATION ModuleWeight 36.96 Lbs # of Modules 46 Total Module Wei ht 1700 Lbs Total Lenoth of Rail 330 Ft Rail Weight per Foot 0.9 Lbs Total Rail Wei ht 296.4 Lbs Wei ht per standoff 2 Lbs Total Standoff W ' ht 172 Lbs Total Array Weight 2168.4 Lbs Point Load 25 Lbs Total Array Area 1 8 30.5 Sq Ft Array Dead Load .6 Lbs/Sa Ft As per ASCE 7 - Method 1:(fig-6-2T------F # to e - 1 11.1 P net =o Kzt 1 Pnet30 eq 6-2 Kzt sec 6.5.7 i net tae - # O1 CLIMACTIC AND Ground Wind Speed Live load, Point Max fastener GEOGRAPHIC DESIGN Category Snow Load 3 sec gust pnet30 per pullout load Fastener Type spacing along CRITERIA W Pg mph ASCE7, psf Ib. rails, in. A # 20 120 # 468 5/16" x 3-1/2" Stainless Steel B # TYP. TYP. # TYP. Lag Bolts W Roof Section # F- 0 Lr)U 72" ,I - GENERAL NOTES 1. CONTRACTOR SHALL CHECK AND VERIFY ALL CONDITIONS AT THE SITE PRIOR TO STARTING TO WORK AND SHALL FAMILIARIZE HIMSELF WITH THE INTENT OF THESE PLANS AND MAKE WORK AGREE THE SAME. 2. CONTRACTOR OR OWNER SHALL OBTAIN ALL REQUIRED APPROVALS, PERMITS, CERTIFICATES OF OCCUPANCY, INSPECTION APPROVALS, ETC., FOR WORK PERFORMED FROM AGENCIES HAVING JURISDICTION THEREOF, IF REQUIRED. 3. ALL WORK SHALL CONFORM TO CONSTRUCTION CODE AND ALL RULES AND REGULATIONS OF THE RESPONSIBLE JURISDICTION. 4. ALL METHODS OF CONSTRUCTION ARE TO BE CAREFULLY SUPERVISED BY THE CONTRACTOR. 5. IF IN THE COURSE OF CONSTRUCTION A CONDITION EXISTS WHICH DISAGREES WITH THAT AS INDICATED ON THESE PLANS, THE CONTRACTOR SHALL STOP WORK AND NOTIFY THE ENGINEER. SHOULD HE FAIL TO FOLLOW THIS PROCEDURE AND CONTINUE WITH THE WORK, HE SHALL ASSUME ALL RESPONSIBILITY AND LIABILITY THEREFROM 6. ALL STRUCTURAL STEEL SHALL BE A-36 AND SHALL BE FABRICATED AND INSTALLED AS PER LATEST A.I.S.0 SPECIFICATIONS. 7. ALL DRYWALL SHALL BE U.S.G. NATIONAL GYPSUM CO. 5/8 " THICK UNLESS OTHERWISE NOTED. 8. ALL ELECTRICAL WORK SHALL BE BOARD OF FIRE UNDERWRITERS APPROVED AND IN ACCORDANCE WITH N.E.C. & NYS CODES & REGULATIONS 9. ANY DEVIATION FROM THESE PLANS WITHOUT THE WRITTEN CONSENT OF THE ENGINEER WILL NEGATE THE ENGINEER'S CERTIFICATION OF THESE PLANS. 10. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR CUTTING, FITTING OR PATCHING REQUIRED TO COMPLETE THE WORK OR TO MAKE ITS PARTS FIT TOGETHER PROPERLY. 11. THE OWNER SHALL SELECT ALL FINISH MATERIALS AND COLORS. 12. THESE DRAWINGS AS INSTRUCMENTS OF SERVICE ARE AND SHALL REMAIN THE PROPERTY OF THE ENGINEER WHETHER THE PROJECT FOR WHICH THEY ARE MADE IS EXECUTED OR NOT. THEY ARE NOT TO BE USED ON ANY OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT EXCEPT BY AGREEMENT IN WRITING AND WITH APPROPRIATE COMPENSATION TO THE ENGINEER. 13. CONTRACTOR SHALL PROTECT, PATCH AND REPAIR ALL EXISTING WORK ADJACENT TO HIS WORK, OR DAMAGED AS RESULT OF HIS WORK. 14. THE SUBCONTRACTORS SHALL PROVIDE ALL EQUIPMENT, TOOLS, FENCES, TRANSPORTATIONS, SAFEGUARDS, ETC., AS REQUIRED FOR THE PROPER EXECUTION OF THEIR WORK. 15. CONTRACTOR TO EFFECT AND MAINTAIN INSURANCE, I.E. CONTRACTOR'S LIABILITY, WORKMAN'S COMPENSATION, COMPLETED OPERATION, ETC. ADEQUATE FOR THE PURPOSES OF THIS PROJECT AND FURNISH PROOF OF SAME PRIOR TO COMMENCING WITH WORK. 16. EACH SUBCONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING SAFETY ON THE JOB SITE DURING THE CONSTRUCTION PHASE TO COMPLY WITH THE REGULATIONS AND REQUIREMENTS OF THE OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION. THIS SHALL INCLUDE, BUT ARE NOT LIMITED TO: PROVIDING FOR ADEQUATE AND PROPER BRACING, SAFETY RAILINGS AND SECURE FOOTINGS FOR ALL TEMPORARY SCAFFOLDING, STAIRS, ETC.. AS WELL AS PERMANENT CONSTRUCTION. 17. FIGURED DIMENSIONS SHALL GOVERN. DO NOT SCALE DRAWINGS, WHERE DIMENSIONS ARE ESTABLISHED BY EXISTING CONDITIONS. EACH CONTRACTOR SHALL VERIFY EXISTING CONDITIONS PRIOR TO ORDERING MATERIALS AND COMMENCING WITH WORK. 18. CONTRACTOR SHALL COORDINATE ALL PHASES OF WORK WITH THE REQUIRED PARTIES. ALL PHASES OF ADJACENT FACILITIES OPERATIONS SHALL BE MAINTAINED DURING CONSTRUCTIONS. CONTRACTOR SHALL KEEP SITE FREE OF CONSTRUCTIONS DEBRIS AND KEEP SITE FULLY ACCESSIBLE TO THE PUBLIC DURING HOURS OF OPERATION. 19. CONTRACTOR TO REMOVE ALL DEBRIS CREATED BY THIS WORK FROM THE SITE AND DISPOSE OF IN A LEGAL MANNER ON A WEEKLY BASIS OR SOONER IF CONDITIONS WARRANT. 20. AT THE COMPLETION OF WORK, THE SITE TO BE CLEARED OF ALL DEBRIS AND EXCESS MATERIALS. THE FACILITY IS TO BE LEFT BROOM CLEAN AND WORK IS TO BE COMPLETED TO THE TOTAL SATISFACTION OF THE OWNER PRIOR TO RELEASE OF FINAL PAYMENT. /rl "]..1n nwr-rrn nlll,n mn /% 1L" —n \- (E) LOAD BEARING WALL \- (E) LBW MODULE MOUNTING SOLAR UNIRAC ALUMINUM PAR ALUMINUM "L" BRACKET COMPOSITION 12i. w I a— 24 in QE0935-� �FESStO10'1 DIST ROOF FRAMING DETAIL 1 SCALE: 1" = 2' STAINLESS STEEL 3/8" BOLT AND NUT ALUMINUM FLASHING _ALUMINUM PV QUICKMOUQT 5/16" x 6" STAINLESS STEEL LAG BOLT WITH 2 1/2" MIN THREAD PENETRATION SEALED WITH GEOCEL 4500 48 in — MOUNTING DETAIL SCALE: 1" = 6" 3i. +1ft 6i. ---► 12 in DESIGN & DRAFTING BY: JAMIE MINNICK NABCEP CERTIFIED 0 5111 2-12 9 REVISIONS DESCRIPTION DATE REV ORIGINAL 11-01-2014 A CONTRACTOR SOLAR UNIVERSE 7470 SOUND AVE MATTITUCK, NY 11952 LICENSE # 43889 H PROJECT NAME W Ln 11.1 Z � U O1 Z �- W W 01— W Z W U) W UWO M~U W m F- 0 Lr)U ,I - SHEET NAME MOUNTING DETAIL & LOAD CALCS SHEET SIZE I SHEET NUMBER PV -4