Loading...
HomeMy WebLinkAbout39154-zTown of Southold Annex P.O. Box 1179 54375 Main Road Southold, New York 11971 CERTIFICATE OF OCCUPANCY No: 37386 Date: THIS CERTIFIES that the building SOLAR PANEL Location of Property: 330 E Legion Ave, Mattituck, 1/16/2015 1/16/2015 SCTM #: 473889 Sec/Block/Lot: 143.4-7 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 8/23/2014 pursuant to which Building Permit No. 39154 dated 9/5/2014 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: ROOF MOUNTED SOLAR PANELS TO AN EXISTING ONE FAMILY DWELLING AS APPLIED FOR The certificate is issued to Morris, Jeryl & Scheidt, Marilyn (OWNER) of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. PLUMBERS CERTIFICATION DATED 39154 10-20-2014 Authorized Signature (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit #: 39154 Date: 9/5/2014 Permission is hereby granted to: Morris, Jeryl & Scheidt, Marilyn 330 E Legion Ave Mattituck, NY 11952 To: construct a roof mounted electric solar panel system as applied for At premises located at: 330 E Legion Ave. Mattituck SCTM # 473889 Sec/Block/Lot # 143.4-7 Pursuant to application dated 8/23/2014 To expire on 3/6/2016. Fees: and approved by the Building Inspector. SOLAR PANELS $50.00 ELECTRIC $100.00 CO - ALTERATION TO DWELLING $50.00 Total: $200.00 Building Inspector TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE SOUTHOLD, NY rtY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit #: 39154 Date: 9/5/2014 Permission is hereby granted to: Morris, Jeryl & Scheidt, Marilyn 330 E Legion Ave Mattituck, NY 11952 To: construct a roof mounted electric solar panel system as applied for At premises located at: 330 E Legion Ave. Mattituck SCTM # 473889 Sec/Block/Lot # 143.4-7 Pursuant to application dated 8/23/2014 To expire on 3/6/2016. Fees: and approved by the Building Inspector. SOLAR PANELS $50.00 ELECTRIC $100.00 CO - ALTERATION TO DWELLING $50.00 Total: $200.00 Building Inspector Town Hall Annex 54375 Main Road P.O. Box 1179 Southold, NY 11971-0959 BUILDING DEPARTMENT TOWN OF SOUTHOLD Telephone (631) 765-1802 Fax (631) 765-9502 roper. riche rt(c-D-town.southold. ny. us CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION Issued To: Marilyn Scheidt Address: 330 E Legion Ave City: Mattituck St: NY Zip: 11952 Building Permit #: 39154 Section: 143 Block: 4 Lot: 7 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: Level Solar License No: 51 I L IDLTAIL5 Office Use Only Residential X Indoor Basement Service Only Commerical Outdoor X 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures HID Fixtures Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Fluorescent Fixture Pumps Transformer Appliances Dryer Recpt Emergency Fixture Time Clocks Disconnect Switches Twist Lock Exit Fixtures �] TVSS Other Equipment: 3.570 KW roof mounted PHOTOVOLTAIC SYSTEM, to include 14-255w panels, 1 -Solar Edge se3800a inverter,A/C and D/C disconnects Notes: Inspector Signature:Date: Oct 20 2014 81 -Cert Electrical Compliance Form.xls Form No. 6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings, property lines, streets, and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage -disposal (S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead. 5. Commercial building, industrial building, multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings (prior to April 9, 1957) non -conforming uses, or buildings and "pre-existing" land uses: 1. Accurate survey of property showing all property lines, streets, building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied, the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy - New dwelling $50.00, Additions to dwelling $50.00, Alterations to dwelling $50.00, Swimming pool $50.00, Accessory building $50.00, Additions to accessory building $50.00, Businesses $50.00. 2. Certificate of Occupancy on Pre-existing Building - $100.00 3. Copy of Certificate of Occupancy - $.25 4. Updated Certificate of Occupancy - $50.00 5. Temporary Certificate of Occupancy - Residential $15.00, Commercial $15.00 Date. 7 - 17 I New Construction: Old or Pre-existing Building: (check one) Location of Property: 3 3O 6,AS-1(_ Lx --6- c omi Awuc it 0160 House No. Street Hamlet Owner or Owners of Property: _ _vod� Suffolk County Tax Map No 1000, Section 1 Block Lot % Subdivision Permit No. Health Dept. Approval: Planning Board Approval: Date of Permit. Request for: Temporary Certificate Fee Submitted: $ Filed Map. Applicant: Underwriters Approval: Lot: Final Certificate: (check one) /1_6 Ap cant" ature UTAH OFFICES Sandy YECTORLayton E n G i n E E R s St. George Project Number: U1521-114-142 December 17, 2014 Level Solar 90 131 Ave. Suite 8 Ronkonkoma, NY 11779 ATTENTION: Eric Negron REFERENCE: Marilyn Scheidt Residence: 330 East Legion Avenue Mattituck, NY 11952 Solar Panel Installation Dear Mr. Negron: Per your request, we have reviewed photographs and a post -installation checklist for the above -referenced site. Based upon our review, it is our conclusion that the installation of solar panels on this existing roof occurred in accordance with the building code and our original requirements as stated in a letter dated July 24, 2014. Rafter size and spacing has been verified to match the original design. Water damage was not encountered during work on and under the existing roof. No pre -installation splits, cuts, breaks, or visible sagging was encountered in the existing roof framing. After installation was complete, it was verified that all roof -penetrating fasteners actually penetrated into the roof framing and did not visibly split the framing members. No existing damage to any existing structure was discovered and no damage was caused to any existing structure during installation, according to the installer. All roof penetrations were sealed and flashed as a means of waterproofing. Our conclusions are based upon our review of the photos and a checklist prepared by the installer. This letter does not waive the installer of any responsibility for improper installation. As stated in a previous letter, our conclusion regarding the adequacy of the existing roof is based on the assumption that all structural roof components and other supporting elements are in good condition and are sized and spaced such that they can resist standard roof loads. We hope this meets your needs. If you have any further questions regarding this matter, please call this office at your convenience. Very truly yours, VECTOR STRUCTURAL ENGINEERING, LLC Roger T. Alworth, P.E. Principal RTA/kbh OF �44� t eo ! 9� � f � A Ob.< 49 • `' �� SSIOW `� 12/17/2014 —1 4 JAN 15 2015 9138 & State Su' e 101 1 Sandy, UT 84070 / T (801) 990-1775 / F (801) 990-1776 / www.vectorse.com o�9 1 ` TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION ] FOUNDATION 1 ST ] FOUNDATION 2ND ] FRAMING/ STRAPPING ] FIREPLACE A CHIMNEY ] FIRE RESISTANT CONSTRUCTION ] ELECTRICAL (ROUGH) ] CODE VIOLATION REMARKS: [ ] ROUGH PLUMBING [ ] INSULATION [ ] FINAL [ ] FIRE SAFETY INSPECTION ( ] FIRE RESISTANT PENETRATION [J ELECTRICAL (FINAL) [ ] CAULKING r,94 cttc, - ol<.,_ C vL 51 �, DATE � � � INSPECTORS' FIELD M3PZCTXON REPORT FOUNDATION (1ST) DATE CONIlVIENTS FOUNDATION (2ND) ROUGH FiTQ & PLUMBING w0 �1 n INSULATION PER N. Y. STATE ENERGY COME Y FINAL ADDZTrONAL`CO NT 7F © - ci . _ m tz b tit t TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL SOUTHOLD, NY 11971 TEL: (631) 765-1802 FAX: (631) 765-9502 SoutholdTown.NorthFork.net Examined S , 20 Approved I 20t�-- Disapproved a/c Expiration , 20�% I AUG 22 2414 4�+ L E1n4D — BUILDING PERMIT APPLICATION CHECKLIST PERMIT NO. Building Inspector Do you have or need the following, before applying? Board of Health 4 sets of Building Plans_ Planning Board approval Survey Check Septic Form N.Y.S.D.E.C. Trustees Flood Permit Storm -Water Assessment Form Contact: Mail to: Phone:,,' CATION FOR BUILDING PERMIT Date Ali q as , 20 INSTRUCTIONS a: -ilius application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans, accurate plot plan to scale. Fee according to schedule. b. Plot plan showing location of lot and of buildings on premises, relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application, the Building Inspector will issue a Building Permit to the applicant. Such a pen -nit shall be kept on the premises available for inspection throughout the work. e. No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim, the Building Inspector may authorize, in writing, the extension of the permit for an addition six months. Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County, New York, and other applicable Laws, Ordinances or Regulations, for the construction of buildings, ad*ions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances, building code, housing code, and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. Ta-r licant o n e, if a corporation) (y /zr' CI l l 1� AVf, r% %, Mailing address of a `li�ant) F , , a , : �t�Pl I�a()L(�(l(y _)�Cl State whether applicant is owner, lessee,,ag6nt, #c`i(tec>jengineer, general contractor, electrician, plumber or builder Name of owner of premises DAT)/S/1 V E?. P. m ._ (As on the tax roll or latest de4E: 3 - BYE �— If applicant is a corporation, signature of duly authorized officer NOTIFY BUILDING DEPARTMENT AT 765-1802 8 AM TO 4 PM FOR THE (Name and title of corporate officer) FOLLOWING INSPECTIONS: 1. FOUNDATION - TWO REQUIRED Builders License No. 15? — FOR POURED CONCRETE Plumbers License No.2. ROUGH - FRAMING, PLUMBING, "' STRAPPING, ELECTRICAL & CAULKING Electricians License No. ��j� A1C~ 3. INSULATION Other Trades License No. 4. FINAL - CONSTRUCTION & ELECTRICAL MUST BE C0'VPLE E FU -1 C.O. 1. Location f land on which proposed work1 be done: ALL CONSTRU ,TI�)^d S'HaLL N EET THE 13:3 O'JIREMEN i S OF THE CODES OF NEN +n, ;-E- c,p��,N121BLE FOR House Number Street Hamlet DESIGN OR CONSTRUCTION ERRORS. County Tax Map No. 1000 Subdivision Section 3 _Block Lot Filed Map No. Lot 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy --J2k5 b. Intended use and occupancy P.Q,3 3. Nature of work (check which applicable): New Building Addition Alteration Repair Removal Demolition Other Work ff[a E 3t)t 6W- 4. Estimated Cost—� s7 Fee (Description) If dwelling, number of dwelling units If garage, number of cars (To be paid on filing this application) Number of dwelling units on each floor 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of existing structures, if any: Front Height Number of Stories Rear Dimensions of same structure with alterations or additions: Front Depth Height Number of Stories Depth Dimensions of entire new construction: Front Rear Depth Height Number of Stories 9. Size of lot: Front Rear 10. Date of Purchase Name of Former Owner 11. Zone or use district in which premises are situated Depth Rear 12. Does proposed construction violate any zoning law, ordinance or regulation? YES NO 13. Will lot be re -graded? YES NO Will excess fill be removed from premises? YES NO 14. Names of Owner of premises njj)e`%&Address_ 3� �. �� aI - Mone No. U31- 29 9-73-8-3Natne of Architect Address Phone No Name of Contractor_ LP,V�.`_SQ� Address `1D 13r IkjcC- �G� phone R�nlCan (Lc�t�(Yy, M\f 0'1'79 15 a. is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO * IF YES, SOUTHOLD TOWN TRUSTEES & D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey, to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. 18. Are there any covenants and restrictions with respect to this property? * YES NO * IF YES, PROVIDE A COPY. STATE OF NEW YORK) SS: COUNTY OF ) JAMIE SCHUSTER NOTARY PUBLIC, STATE OF NEW YORK NO. 01 S0611, 2194 QUALIFIED IN SUFFO�,K COUNTY COMMISSION' EXPIRES JULY 6, 201110 hpp ( being duly sworn, deposes and says that (s)he is the applicant (Name of individual signing contract) above named, (S)He is the (Contractor, Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be performed in the manner set forth in the application filed therewith. Sworn to before me this 2l �dnay off Auq 20 it- _ Notary Pub tc Sig e of Applicant r 'aos��xk Scott A. Russell SUPERVISOR SOUTHOLD TOWN HALL - P. O. Box 1179 tQ 53095 Main Road- SOUTHOLD, NEW YORK 11971 S U O)IKJMMA,T]E)E, MA,NA\(G IE LENT 'own of Southold CHAPTER 236 - STORMWATER MANAGEMENT -'WORK SHEET ( TO BE COMPLETED BY THE APPLICANT) DOES THIS PROJECT IWO= ANY OF '111K (CHECK ALL THAT APPLY) _ A. Clearing, grubbing, grading or -stripping of land which affects more than 5,000 square feet of ground surface. ; B. Excavation or filling involving more than 200 cubic yards -of material within any parcel or any contiguous area. C. Site preparation on slopes which exceed 10 feet vertical rise to ` 1- 10.0 feet of horizontal distance. D. Site preparation within 100 feet of wetlands, beach, bluff or coastal erosion hazard area. E. Site preparation within the one -hundred -year floodplain as depicted on FIRM Map of any watercourse. F. Installation of new -or resurfaced impervious surfaces of 1,000 square feet or more, unless prior approval of a Stormwater Management , Control Plan was received by the Town and the proposal includes in-kind replacement of impervious surfaces. If you answered NO to all of the questions above, STOP'. Complete the Applicant section below with your Name, Signature, Contact Information, Date & County Tax Map Number! Chapter 236 does not apply to your project. If you answered YES to one or more of the above, please submit Two copies of a Stormwater Management Control Plan and a completed Cbeck Dist Form to the Building Department with your Building Permit Application. APPLICANT: (Property Owner, Design Professional, Agent, Contractor, Other) NAME: IG t - Coni3Ct tnforort rrckp4 Mme d Property Address / Location of Construction Work: 330 E. Le for Av;7ve Ma44i-TLk IU 1(gSa FORM - SMCP - TOS MAY 2014 S.C.T.M. 1000 Date District 1q3 q Section Block Lot FOR BUILDING DEPAKT IG)�IT USE OINLY Reviewed By: &)-nw &/� - Date: — — — — — — — —14 Approved for processing Building Permit- — — Stormwater Management Control Plan Not Required. ❑Stormwater Management Control Plan is Required. (Forward to Engineering Department for Review.) Town Hall Annex 54375 Main Road P.O. Box 1179 Southold, NY 11971-0959 Telephone (631) 765-1802 roaer.richertCd ouim lsoW5nv us Wa DING DEPARTNEW TOWN OF SOLrrHOLD APPLICATION FOR ELECTRICAL INSPECTION I�LjcREQUESTED imu Date: _71ROV ense No.: .• r Address: Z"M 11 MA �,'tft"oneNo.: • JOBSITE INFORMATION: (*Indicates required information) *Name: *Address: *Cross Street: *Phone No.: a _ Permit No.: I Tax -Map District: 1000 Section: Block: *BRIEF DESCRIPTION OF WORK (Please Print Clearly) Lot: (Please Circle All That Apply) *Is job ready for inspection: YES / NO. Rough In Final *Do. you need a Temp Certificate: YES / NO Temp Information (If. needed) *Service Size: 1 Phase 3Phase 100 150 200 300 350 400 Other *New Service: Re -connect Underground Number of Meters Change of Service Overhead Additional Information: PAYMENT DUE WITH APPLICATION 82 -Request for Inspection Form TOWN OF SOUTHOLD PkOPERTY RECORD CARD , vt ,� - OWNER STREET VILLAGE DISTRICT -SUi — 7 ( j/ FORMER OWNER N E t ---ACREAGE , 2 _ W TYPE OF BUILDING SEAS. - VL. FARM COMM. I IN I CB. I MISC. LAND IMP. TOTAL DATE REMARKS LOT . � � r r I Est. Mkt. Value //00 00 0 1,3(9 .g... 0 c, ` .� 17 f es'7.4,m 4 ,rfd, e o4y h, r f! Ra y 1, d �- t (lct t�Y' ; j 77- L t r/IfT i 0 30o 3aoc 27o a00 3 b'OC '� tXo 3> " Gt.lt . SAGE�2Q ply Q Acre , { UILDIN C D 40 �I l - L (_ u�T EI�C1 A OVE FRONTAGE ON WATER Value Per Acre Value FRONTAGE ON ROAD '1�#" 3— 1,q W '� Farm BULKHEAD Tillable 1 DOCK Tillable 2 Tillable 3 0 -L 12 — Woodland� ),z(p _2 o YQ e- �d Q • Swampland %� Brushland House Plot Total w -m, -aw -we* Town Hall Annex 54375 Main Road P.O. Box 1179 Southold, NY 11971-0959 October 23, 2014 Level Solar 9013 th Ave, Suite 8 Ronkonkoma NY 11779 BUILDING DEPARTMENT TOWN OF SOUTHOLD Telephone (631) 765-1802 Fax (631) 765-9502 RE: Scheidt, 330 E Legion Ave, Mattituck TO WHOM IT MAY CONCERN: The Following Items (if Checked) Are Needed To Complete Your Certificate of Occupancy. "Note: We need certification from an architect or engineer that the panels were installed on the roof per NYS Building Code Application for Certificate of Occupancy. (Enclosed) Electrical Underwriters Certificate. A fee of $50.00. Final Health Department Approval. Plumbers Solder Certificate. (All permits involving plumbing after 4/1/84) Trustees Certificate of Compliance. (Town Trustees # 765-1892) Final Planning Board Approval. (Planning # 765-1938) Final Fire Inspection from Fire Marshall. Final Landmark Preservation approval. Final inspection by Building Dept. Final Storm Water Runoff Approval from Town Engineer 5q -- 30L -A-2 BUILDING PERMIT — SOLARpermits@levelsolar.com90 13t" Avenue, Unit 8, Ronkonkoma, NY 11779 631-285-2557 January 9, 2015 Town of Southold Building Department ' i JAN 1 5 2015 �I 54375 Route 25 PO Box 1179 Southold, NY 11971 RE: Permit #39154 330 East Legion Ave, Mattituck To whom it may concern: Enclosed please find an Engineers letter to close out the above referenced permit. Please mail a copy of the Certificate of Compliance to our office at 90 13th Avenue, Unit 8 Ronkonkoma, NY 11779 for our records. Please call 631-285-2557 if you have any questions or problems. Thank you, amie Schuster Permitting Specialist Level Solar Town of Southold Construction Permit Customer: Marilyn Scheidt 330 East Legion Avenue Mattituck, NY 11952 (631) 298-7283 Tax ID: Contractor: Level Solar 90 13th Avenue, Ste. 8 Ronkonkoma, NY 11779 631-285-2555 Item # Document 1 Structural Engineer Letter 2 Three Line Electrical Diagram 3 Array Design 4 Mounting Diagram 5 Equipment Data Sheets Town of Southold Building and Solar Permit Application Pack Customer: Marilyn Scheidt 330 East Legion Avenue Mattituck, NY 11952 (631) 298-7283 Tax ID: 1q,�-q -% Contractor: Level Solar 90 13th Avenue, Ste. 8 Ronkonkoma, NY 11779 631-285-2555 Item # Document # Copies 1 Building Permit Application 1 2 Certificate of Occupancy 1 3 1 st Page of Storm Water Application 1 4 Electrical Inspection Form 1 5 Land Survey 1 6 Insurance Pack 1 F�sT 306 x/ S °6 ., 1.2' r V N,' T'lRpe- Y GUARANTEES INDICATED HERE ON SHALL RUN ONLY TO THE PERSON FOR KNOW THE SURVEY IS PREPARED, AND ON HIS BEHALF TO THE T7TL£ COMPANY, COVERNMENTAL AGENCY, LENDING INSTITUTION, IF LISTED HEREON, AND TO THE ASSIGNEES OF THE LENDING INSTITUTION. GUARANTEES ARE NOT TRANSFERABLE TO ADDJ770NAL INSTITUTIONS OR SUBSEQUENT OWNERS. UNAUTHORIZED ALT£RARON OR ADDITION TO THIS SURVEY IS A VIOLATION OF SECTION 7209 OF THE NEW YORK 5TATE EDUCATION LAW. COPIES OF THIS SURVEY MAP NOT BEARING THE LAND SURVEYORS EMBOSSED SEAL SHALL N1Il 9i CONSIDERED TO BE A VALID TRUE C 1P 1 SURVEY OF DESCRIBED PROPERTY SITUATE MATTITUCK, TOWN OF SOUTHOLD SUFFOLK COUNTY, N.Y. 0440 SURVEYED FOR: MARILYN S. SCHEIDT JERYL A. MORRIS I. 10 JONE 2009 LOCATE rv1dCD CONC. FOUNDATION. TM# 1000-143--04--007 GUARANTEED GUARANTEED TO: MARILYN S. SCHEIDT JEERYL A. MORRIS SURVEYED: 27 APRIL 2009 SCALE 1 "= 20' AREA = 7,801 S.F. OR 0.179 ACRES SURVEYED BY STANLEY J. ISAKSEN, JR. P.O. BOX 294 NEW SUF OLK. N.Y. 1 7 956 631 —731-5835 — '... _�--. / �NS L�1 RVE�OR^ NYS L, Nc�. 273 09R1719 I(Z SEP As weeqre3 !f-at:t-e Icersda IV WWI if Jt mak sew 2y 5 STATE OF NEW YORK WORKERS' COMPENSATION BOARD CERTIFICATE OF INSURANCE COVERAGE UNDER THE NYS DISABILITY BENEFITS LAW PART 1. To be corn p aced by Disability Bene is Carrier or Licensed Insurance Agent of that Carrier 1 a. Legal Nance and Address of Insured (Use street address only) lb. Business Telephone Number of Insured LEVEL SOLAR INC (631) 285-2555 527 HUDSON STREET SUITE lc. NYS Unemployment Insm-mce Employer Registration NEW YORK, NY 10014 Number of Insured 1 d. Federal Employer Identification Number of Insured or Social Securitv Number 464-06-0893 2. Name and Address of the Entity Retesting Proof of 3a. Name of Insurance Carrier Coverage (Entity Being Listed as the Certificate Holder) 14EW YORK STATE INSURANCE FUND Town of Southold 54375 Route 25 3b. Policy Number of entity listed in box "la": Southold, NY 11971 DBL 6430 71 - 5 3c. Policy effective period: 12118/2013 to 12/18/2014 4. Po 4 overs: a. ( All of the employer's employees eligible under the New York Disability Benefits Lase b. Only the following class or classes of the employer's employees: Under penalty of perjury; I certify than I aur an authorized representative or licensed agent of the km rangy carrier referenced above and that the named insured has NYS Disability Benefits insurance coverage as described above. Date Signed 04/24/2014 By""""e ' Joseph J. Masi (Sigrettroe of irsuranae v rdeesauthorized repramnatiue of WSUGarsed insura rre FBent of that irisurarne mwrier) Telephone Numb" (866) 697-4332 Title director of Disability Benefits Insurance 04PORTA T- if box '43" is checked, sled dtis foma is aped by the Wsupow carrier`s w 6orixod retuesm ative or NYS Liccussed lusu tUee Agam of dot carrier. Otis cadficee is COMMEM Mail it dbeetly to dee cet"cm boWa. 1P boss `4b" is checked. this terniificc m is NOT COMPLETE W purposet of Sectim 220. Subd. $ of the Dieabdity Basins Law. It mutt be mailad for completion to &c Wotkt& Comped ser im Do" DB Plass Acceptance Uait. 20 Putt Street, Albu►y. New Yo* 12207. PART 2. To be completed by NYS WorkerV Compensation Boa On x *4b" of Part 1 has been ) State Of New York Workers' Compensation Board Aocof&4 to mformtion tnaummed by the NYS Workers` Compensation Board, the above -rimed egtployer has complied with the NYS Disability Seneftts Law with respect to all of biw%er employees_ Date Signed By (Signature of lh'YS Workers' Competwdon Board Employee) Telephone Number Title Please Note: only tnsufance carriers licensed to write NYS disability benefits insurance policies and NYS licensed insurance agents of those insurance carriers are authorized to issue Foran DB -120.1. Insurance brokers are NOT authorized to issue this form. De -120-1 (5-06) Certificate Number 259441 -10 ACORD CERTIFICATE OF LIABILITY INSURANCE DATE (MMIDD/YYYY) 2/28/2014 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the policy(ies) must be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER Diversified Insurance Group 136 E. South Temple Street Suite 2300 Salt Lake City UT 84111 CONTACT MegQuincy Ny AME: PHONE (801) 325-5000FAX N (801)532-2804 ADDRESS:-noorda@divers if iedinsurance. com, INSURERS AFFORDING COVERAGE NAIC q INSURERA.Colony Insurance Company INSURED Level Solar Inc. 527 Hudson Street, Ste 20-170 New York NY 10014 INSURERB:Sentinel Insurance CO 11000 INSURER C: INSURER D: INSURER E: INSURER F: 11n%1=oAr_1Oe CFRTIFIRATF (VI IMRFR•2013 REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR LTRWVD TYPE OF INSURANCE ADDL B POLICY NUMBER MM/DD/YYYY Y EFF MM/DD EXP LIMITS A GENERAL LIABILITY X COMMERCIAL GENERAL LIABILITY CLAIMS -MADE OCCUR Regan Guth/MQ Epx301882 2/4/2013 12/1/2014 EACH OCCURRENCE $ 1,000,000 DAMAGE T5 R PREMISES Ea oc Dnc $ 50,000e) MED EXP (Any one person) $ 5,000 PERSONAL & ADV INJURY $ 1,000,000 GENERAL AGGREGATE $ 2,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: FX -]POLICY r PRO LOC PRODUCTS - COMP/OP AGG $ 2,000,000 $ B AUTOMOBILE LIABILITYCOMBINED X ANY AUTO ALL OWNED SCHEDULED AUTOS AUTOS NON -OWNED HIRED AUTOS AUTOS 4UECAQ7826 1/25/2013 11/25/2014 SINGLE LIMIT Ea accident 11000,000 BODILY INJURY (Per person) $ BODILY INJURY (Per accident) $ PROPERTYDAMAGE $ Peraccident) TERR $ UMBRELLA LIAR EXCESS LIAB HOCCUR CLAIMS -MADE EACH OCCURRENCE $ AGGREGATE $ DED RETENTION $ WORKERS COMPENSATION AND EMPLOYERS' LIABILITY ANY PROPRIETOR/PARTNER/EXECUTIVE Y / N OFFICER/MEMBER EXCLUDED? ❑ (Mandatory In NH) If yes. describe under DESCRIPTION OF OPERATIONS below N I A WC STATU-TS1 OTH- 111 E.L. EACH ACCIDENT $ E.L. DISEASE - EA EMPLOYE $ E.L. DISEASE - POLICY LIMIT $ DESCRIPTION OF OPERATIONS I LOCATIONS I VEHICLES (Attach ACORD 101, Additional Remarks Schedule, if more space is required) CFRTIFICATF HOLDER CANCELLATION ACORD 25 (2010/05) ©1988-2010 ACORD CORPORATION. All rights reserved. INS025 mmnns m Tha Arr1Rr1 name and Inn^ aro ranictcrarl markt ^f arnpi i SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. Town Of Southold 54375 Route 25 AUTHORIZED REPRESENTATIVE Southold, NY 11971 Regan Guth/MQ ACORD 25 (2010/05) ©1988-2010 ACORD CORPORATION. All rights reserved. INS025 mmnns m Tha Arr1Rr1 name and Inn^ aro ranictcrarl markt ^f arnpi i New York State Insurance Fund Workers' Compensation & Disability Benefits Specialists Since 1914 199 CHURCH STREET, NEW YORK, N.Y. 10007-1100 Phone: (212) 587-2149 CERTIFICATE OF WORKERS' COMPENSATION INSURANCE ^ ^ ^ ^ ^ ^ 464060893 LEVEL SOLAR INC (A DE CORP) 527 HUDSON STREET, SUITE 20-170 NEW YORK NY 10014 POLICYHOLDER LEVEL SOLAR INC (A DE CORP) 527 HUDSON STREET, SUITE 20-170 NEW YORK NY 10014 CERTIFICATE HOLDER TOWN OF SOUTHOLD 54375 ROUTE 25 SOUTHOLD NY 11971 POLICY NUMBER CERTIFICATE NUMBER PERIOD COVERED BY THIS CERTIFICATE DATE L 2317 408-9 36454 12/11/2013 TO 12/11/2014 3/14/2014 THIS IS TO CERTIFY THAT THE POLICYHOLDER NAMED ABOVE IS INSURED WITH THE NEW YORK STATE INSURANCE FUND UNDER POLICY NO. 2317 408-9 UNTIL 12/11/2014, COVERING THE ENTIRE OBLIGATION OF THIS POLICYHOLDER FOR WORKERS' COMPENSATION UNDER THE NEW YORK WORKERS' COMPENSATION LAW WITH RESPECT TO ALL OPERATIONS IN THE STATE OF NEW YORK, EXCEPT AS INDICATED BELOW. IF SAID POLICY IS CANCELLED, OR CHANGED PRIOR TO 12/11/2014 IN SUCH MANNER AS TO AFFECT THIS CERTIFICATE, 10 DAYS WRITTEN NOTICE OF SUCH CANCELLATION WILL BE GIVEN TO THE CERTIFICATE HOLDER ABOVE. NOTICE BY REGULAR MAIL SO ADDRESSED SHALL BE SUFFICIENT COMPLIANCE WITH THIS PROVISION. THE NEW YORK STATE INSURANCE FUND DOES NOT ASSUME ANY LIABILITY IN THE EVENT OF FAILURE TO GIVE SUCH NOTICE. THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS NOR INSURANCE COVERAGE UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICY. NEW YORK STATE INSURANCE FUND C� DIRECTOR, INSURANCE FUND UNDERWRITING This certificate can be validated on our web site at https://www.nysif.com/cert/certval.asp or by calling (888) 875-5790 VALIDATION NUMBER: 845119282 U-26.3 HE I Sandy ECTORLayton yr ynGinEERS St. George Project Number: U1521-114-141 July 24, 2014 Level Solar 90 13" Ave. Suite 8 Ronkonkoma, NY 11779 ATTENTION: Eric Negron REFERENCE: Marilyn Scheidt Residence: 330 East Legion Avenue Mattituck, NY 11952 Solar Panel Installation Dear Mr. Negron: Per your request, we have reviewed the attached calculations and photos relating to the installation of solar panels at the above -referenced site. Based upon our review, it is our conclusion that the installation of solar panels on this existing roof per the attached documents and in accordance with Zep Solar's and Level Solar's installation requirements will not adversely affect the structure of this home. We have found the calculations to be in accordance with the 2010 Building Code of New York State and ASCE 7-05. This conclusion is based upon the fact that the additional weight related to the solar panels is less than three pounds per square foot. In the area of the solar panels, other live loads will not be present. Regarding snow loads, it is our conclusion that since the panels are slippery, dark, and located only on the south facing roof elements, effective snow loads will likely be reduced in the areas of the panels. In addition, it is our conclusion that any additional wind or seismic loadings related to the addition of these solar panels is negligible. The solar panels and attachments have been designed to withstand 125 mph design wind speed (3 -second gust). Solar panels will be flush -mounted, parallel to and no more than 6" above the roof surface. Installation of the solar panels must be performed in accordance with Zep Solar's and Level Solar's installation requirements. Particular attention must be paid to the maximum allowable spacing of attachments and the location of solar panels relative to roof edges. The use of span tables provided by Zep Solar is allowed only where the building type, site conditions, and solar panel configuration match the description of the span tables. The installer is responsible to seal around roof penetrations to prevent leaks. All work performed must be in accordance with accepted industry -wide methods and applicable safety standards. Vector Structural Engineering assumes no responsibility for improper installation of the solar panels. Please note that we have reviewed photos taken of the roof framing (attached), but a representative of Vector Structural Engineering has not physically observed the roof framing of this home. Our conclusions are based upon our review of the photos which indicate that all structural roof components and other supporting elements are in good condition and are sized and spaced such that they can resist standard roof loads. Roof framing type, size, and spacing are as indicated in the attached photos and drawings by Level Solar. We hope this meets your needs. If you have any further questions regarding this matter, please call this office at your convenience. Very truly yours, VECTOR STRUCTURAL ENGINEERING, LLC Roger T. Alworth, P.E. Principal Enclosures 0r '46 1 py. T Q— ?� �� 7/24/2014 9138 S. State St., Suite 101 l Sandy; t = '_:- f (8Q1} 990-17751 F (801) 990-1776 / www,vectorse.com Yingli YL255P-29b 255 Watts Voltage at Pmax (STC) = 30.0 Vdc Current at Pmax (STC) = 8.49Adc Open Circuit Voltage = 37.7 Vdc Short Circuit Current= 9.01 Adc SolarEdge Power Optimizer P300 Rated DC Input Power - 300 watts Maximum Input Voltage -48 Vdc MPPT Range - 8 to 48 Vdc Maximum Input Current - 10 Adc Maximum Output Current - 15 Adc String Limitations - 8 to 25 Optimizers, 5250 watts STC per string maximum System Labels To utility Grid DC input Power = 3570 Watts STC Maximum DC Voltage =500 Vdc 120/240 Vac Nominal Operating Voltage = 350 Vdc 6011z (14x255W) Maximum DC Current= 15.0 Adc per string LS L2 N Nominal Operating Current =12.5 Adc Max. , • • • 1 13 1 1 14 r- SolarEdge SE38DOA-US Inverter 97.5% CEC Efficiency @ 240 Vac 3800 Wac continuous Maximum Output Current 16.0 Arms Maximum Input Current 12.5 Adc Ground -fault protection provided per NEC article 690.35 - SolarEdge AC/DC Safety Switch 300 Vac, 32 Amps continuous 600 Vdc, 32 Amps continuous Opens all ungrounded conductors per NEC article 690.35 Optimizer Equipment Grounding Li requirement Is satisfied by the mechanical connection N to the Zap module frame ca L— PV Wire in Free Air or THHN-2 / THWN-2 in conduit Minimum 12 AWG Cu wire each (rated 90 deg C) Positive, Negative Bare Copper EGC or insulated EGC In conduit Keep under 2% voltage drop Revenue Grade Meter Main Breaker 100 Amp typ. AC Load Center Inverter Connected to 1- 2 Pole 20 Amp Circuit Breaker GEC Minimum 12 AWG Cu Wire (rated 75 deg C) L3, L2, and neutral Ground 10 AWG Ground wire Keep under 1.5% voltage drop ROOF OBSTRUCTION (TYPICAL) DRIVEWAY \_-- 3,570 WATT ROOFTOP PV SYSTEM (14 PANELS @ 255 WATTS EACH) SLOPE = 45°, AZIMUTH = 164°, SOLAR ACCESS = 54% INVERTER WITH \ A/C DISCONNECT ELECTRICAL METER \ PV INTERCONNECT 50' OF %" PVC CONDUIT FROM JUNCTION BOX TO INVERTER STRUCTURAL ONLY STRUCTURAL ONLY OF N�t,� t A# ' j 7/24/201 RAKE OF ROOF 3,570 WATT ROOFTOP PV SYSTEM (14 PANELS @ 255 WATTS EACH) SLOPE = 45° 5„ [5„] (RECOMMENDED 3” —�- MINIMUM OFFSET) EAVE OF ROOF 14" [1'-2"] (12Y2' MINIMUM) CLEARANCE FOR COMP MOUNT RAKE OF ROOF L ESTIMATED RAFTER/ TRUSS LOCATION (7" MINIMUM) CLEARANCE FOR COMP MOUNT 222" [18'-6"] Yingli YGE-Z 60 Series 1 Panel 12 Panels 3 Panels 4 Panels 15 Panels 6 Panels Spacing Calculations Interior Edge I Corner L E V E L Build Plan Over 65.00" 130.50" 196.00" 261.50" 327.00" 392.50" Max SPACING 64.0" 48.0" 48.0" Landscape Landscape70872 5 O L A R Up 39.50" 79.00" 118.50" 158.00" 197.50" 237.00" Max CANTILEVER 22.2" 20.3" 20.3" Marilyn Scheidt Over 39.00" 78.50" 118.00" 157.50" 197.00" 236.50" Max SPACING 32.0" 32.0" 32.0' 90 13th Avenue, Suite 8 Ronkonkoma, NY 11779 330 East Legion Avenue g Portrait Up 65.50" 131.00" 196.50" 262.00" 327.50" 393.00" Portrait Max CANTILEVER 15.2" 12.5" 12,5" (631) 285-2555 Mattituck, NY 11952 Rafter/Truss Spacing: 16" on center Clear Access: 18" @ Ridge, 18" path from Eave to Ridge Roof Category: C Zone Boundaries: 36.0" BRN BY Joey Liao 07/21/14 SHEET 1 of 1 REV 01 Customer Information: Customer Number Name Address City, State, Zip Design Information: 236 W 30th Street, Suite 600, New York, NY 10001 844 -GO -LEVEL 70872 Marilyn Scheidt 330 East Legion Avenue Mattituck, NY 11952 Number of Faces Used 1 Exposure Category C Wind Speed 125 mph Ground Snow Load (Pg) 30 psf Importance Factor (1) 1.0 Topographic Factor (Kzt) 1.0 Thermal Factor for Snow Load (Ct) 1.2 Exposure Factor for Snow Load (Ce) 0.9 Effective Wind Area 10 Solar Array Details: Number of Modules Module Type Modules Size Array Size Module Weight Module Area mizer, Mount & Others Details: Optimizer Type Optimizer Weight Roof Type Mount Type Attachment Type Attachment Weight (Leveling Foot and Comp Mount) Interlock Weight 14 Yingli YGE-Z Series - YL255P-29b 255 W 3.570 kW 45.2 lbs 17.6 ft. sq. SolarEdge P300 2.1 lbs Composition Shingle Zep Solar ZS Comp Comp Mount, Type C 1.98 lbs 0.55 lbs SOLAR236 W 30th Street, Suite 600, New York, NY 10001 844 -GO -LEVEL Surface Information: Landscape Face 1 Average Roof Height 20 ft Number of Modules 14 Least Horizontal Dimension 26 ft Number of Optimizers 14 Slope 45 deg Number of Attachments 28 Truss Spacing 16 in Number of Interlocks 11 Edge and Corner Dimension (a) 3.0 ft 0.5 Distributed and Point Load Calculations: (SolarABC's Expedited Permit Process for PV System (EPP)) Face 1 Total System Weight (modules, optimizers, mounting system, etc.) 723.7 lbs Total Array Area 246.2 ft. sq. Distributed Weight 2.94 psf Weight per Attachment Point 25.8 lbs Snow Load Calculation: (ASCE 7-05 Section 7) Landscape Face 1 Interior Edge Corner Unit Flat Roof Snow Load (Pf) 22.7 22.7 22.7 psf Slope Factor (Cs) 0.5 0.5 0.5 48.0 Roof Snow Load (Ps) 10.3 10.3 10.3 psf Wind Pressure Calculations: (ASCE7-05 Section 6.4) 20.3 15.2 12.5 Facet Interior Edge Corner Unit Net Design Wind Pressure uplift (Pnet30_up) -28.1 -32.9 -32.9 psf Net Design Wind Pressure downforce (Pnet30_down) 25.7 25.7 25.7 psf Adjustment Factor for Height and Exposure Category (A) 1.3 1.3 1.3 Net Design Wind Pressure uplift (Wup) -36.2 -42.4 -42.4 psf Net Design Wind Pressure downforce (Wdown) 33.2 33.2 33.2 psf ASD Load Combination: (ASCE7-05 Section 2.4) Face 1 Interior Edge Corner Unit Dead Load (D) 2.1 2.1 2.1 psf Snow Load (S) 5.2 5.2 5.2 psf Load Combination 1= D+0.755+0.75Wdown 30.8 30.8 30.8 psf Load Combination 2 = D+Wdown 35.2 35.2 35.2 psf Load Combination 3 = D+S 7.2 7.2 7.2 psf Uplift Design Load = 0.6D+Wup -35.0 -41.2 -41.2 psf Maximum Absolute Design Load (Pabs) 35.2 41.2 41.2 psf Spacing Calculation: (Zep Solar Product Manual) Orientation: Zone: Max spacing between attachments (in) Max. spacing between attachments considering rafter spacing (in) Max cantilever from attachments to perimeter of PV Array (in) Face 1 Landscape Portrait Interior Edge Corner Interior Edge Corner 66.5 61.0 61.0 45.5 37.5 37.5 64.0 48.0 48.0 32.0 32.0 32.0 22.2 20.3 20.3 15.2 12.5 12.5 Statement of Estimated Cost Marilyn Scheidt No. of Modules Module Power (W; DC) Total Array Size (W; DC) Array Size (kW; DC) Cost / kW; DC Total Array Price; DC 14 255 3,570 3.570 $5,000 $17,850 LEVELING FOOT MOUNTED ON COMP MOUNT TYPE A WATERPROOFING SFAI.ANT AS NEEDEF. COMP MOUNT TYPE A .- - N STAINLESS STEEL 5/16"o x 1" M.B. i WASHER PACKAGFD 1 1 WITH COMP MOLINT _i STAINLESS STEEL LAG SCREW, 5/16"O X 41/2" LEVEEING FOOT ON COMP Mrn IIVT T VrE � CANTILEVER= L=PERMITTED SPACING L 3 OR LESS SEE CODE COMPLIANCE LETTER FOR ALLOWABLE SPACING INTERLOCK PPHOTOVOLTA C MODULE LEVELING FOOT ROOF FRAMING HYBRID INTERLOCK LrnrvlR=I/a �CJ?SlUltdT1AU LESS tulll.l,_k!ll l,jVJtl-L NTATjQN -()1I TL IN ()r .",)()I l(L ZfP IfV1IING FOOT INTERLOCK IIVRRII)INIERIOCK �t [30.7mml 1.21 in [ 81.2mm ] 3.20in -=T 1.26in I Lower balance-of-systam costs with Zap Compatible'" frame. Reduce on -roof labor costs by more than 25%. Leverage the built-in grounding system - if it's mounted, it's grounded. Lower your parts count - aliminate rails, screws, mounting clips, and grounding hardware. Design and permit projects easily with access to layout calculator and stamoed drawings. Lower installation costs with savings across equipment and labor. Minimize roof penetrations while maintaining the system's structural integrity. Invest in an attractive solar array that includes a black frame, low mounting profile, and aesthetic array skirt. Increase energy output with flexible module layouts (portrait or landscape). Trust in the reliability and theft -resistance of the Zap Compatible" system. 'K 34The YGE-Z Series is now available as an Enphase Energized -AC Solution. This solution delivers ootmum ' performarce and ntegratad intelligence. The Enphase X1215 -Z Zep Compatible Uicroinverer is designed ro connect diractiy nto the Z Series module groove, eliminating the need or cools or fasteners - all with one easy step. mreilganr real -rime mon tonng 3t he ;ystem - 3rd nodule 'avei -nnrh U.S. Soccer Pa—)eed by `.'ingli Solar V'! �t Leading limited power warranty- ensures 91.2% of rated power for 10 years, and 30.7% of rated power for 25 years. 10 -year limited product warranty. ' !n :omoliance with our Narr3rry terns and :ordi;ions. UL 170, and L- 1 703. =SEZ. SO X01_2008. SJ 14C01 20C4 3S:)HSA3 BCCI 2CC' SA80CC C I�S) us -V INTH ..,�.'VIL i40D i Lower balance-of-systam costs with Zap Compatible'" frame. Reduce on -roof labor costs by more than 25%. Leverage the built-in grounding system - if it's mounted, it's grounded. Lower your parts count - aliminate rails, screws, mounting clips, and grounding hardware. Design and permit projects easily with access to layout calculator and stamoed drawings. Lower installation costs with savings across equipment and labor. Minimize roof penetrations while maintaining the system's structural integrity. Invest in an attractive solar array that includes a black frame, low mounting profile, and aesthetic array skirt. Increase energy output with flexible module layouts (portrait or landscape). Trust in the reliability and theft -resistance of the Zap Compatible" system. 'K 34The YGE-Z Series is now available as an Enphase Energized -AC Solution. This solution delivers ootmum ' performarce and ntegratad intelligence. The Enphase X1215 -Z Zep Compatible Uicroinverer is designed ro connect diractiy nto the Z Series module groove, eliminating the need or cools or fasteners - all with one easy step. mreilganr real -rime mon tonng 3t he ;ystem - 3rd nodule 'avei -nnrh U.S. Soccer Pa—)eed by `.'ingli Solar V'! �t Leading limited power warranty- ensures 91.2% of rated power for 10 years, and 30.7% of rated power for 25 years. 10 -year limited product warranty. ' !n :omoliance with our Narr3rry terns and :ordi;ions. UL 170, and L- 1 703. =SEZ. SO X01_2008. SJ 14C01 20C4 3S:)HSA3 BCCI 2CC' SA80CC C I�S) us -V INTH ..,�.'VIL i40D Module type J6 */- 2 Temperature coefficient of P.... y 9i/°C YL255P-29b YL250P-29b YL245P-29b YL240P-29b YL235P-29b Power output P„°. W 255 250 245-240 Limiting reverse current 235 Power output tolerances Ap- W 50 psf (2400. a) Max. static load, back (e.g., wind) A/*5 Hailstone impact I m '25 mm) at 51 mph ;_3 reds) Module efficiency rim % 15.6 15.3 15.0 14.7 14.4 Voltage at P.,,.. V_ V 30.6 30.4 30.2 29.5 29.5 Current at Pm.. 1- A 8.32 8.24 8.11 8.14 7.97 Open -circuit voltage V_ V 38.7 38.4 37.8 37.5 37.0 Short-circuit current Ir A 8.38 8.79 8.63 8.65 8.54 _. IOOOW/m+ 25'^_ _ed :emoerature. AMI Sg ;pectrum according :o EN 5004-3 Average -91aove eificuency -educvon of 5.J°5 at 20OW/ma according --o 2N i0904-1 Power output Pte.. W 184.7 a 181.1 177.9 174.3 170.7 . Voltage at P„°° V,mn V 27.9 27.6 27.2 26.6 26.6 Current at P_ L,v,aa A 6.63 6.56 6.S4 6.56 6.42 Open -circuit voltage V: V 35.7 35.4 34.5 34.2 33.3 Short-circuit current I°. A 7.19 7.11 6.99 7.01 6.92 NCCT: open- rt module iperation •empenwm at 3C0W/m� .Radiance. 200; amotent tamow3wre. I m/s mrd ;peed Nominal operat ng cell temperature NOCr 'C J6 */- 2 Temperature coefficient of P.... y 9i/°C -0.45 Temperature coefficient of V: {lv.. 1W'C -0.33 Temperature coefficient of Im a.. lfv'•C 0.06 Temperature coefficient of V-, Bv-.. 'Nw'C -0.45 Max. system voltage _.- - 600Voc - ---- - -- -- --- -- - - - --- Max. series fuse rating --------------- I SA Limiting reverse current ISA Operating temperature range -40 to 194'. (-40 to 90"') Max. static load, front (e.g., snow and wind) 50 psf (2400. a) Max. static load, back (e.g., wind) 50 psf (2400 Pa) Hailstone impact I m '25 mm) at 51 mph ;_3 reds) Front cover (material/type/thickness) Call ;quantity/material/type/dimensions/ area/# of busbars) Encapsulant ;material) Frame (material/color) Junction box (protection degree) Cable (type/length/gauge/outside diameter) Plug connector (manufacturer/type/protection degree) Low -iron glass / tempered : 3.2 mm Glass may have anti -reflective =oating 60 polysilicon / multicrystalline / 156mms156mm/243.3cm2/2or3 Ethylene ,nyl acetate .EVA) Anodized aluminum alloy ' black >IP65 PV Wire '43.31 .n 11100 mm) ' 12 AWG ' 0.244 n ,6.2 mm) Amphenol H4. IP68 Tie ;peclflcat,ons .n th,; datashaet 3n_ not duar3ntaed and are 3ublact a _han9e adhout poor notica This datasheet _omphes Neth =N 30380:2003 requirements Yingli Green Energy Americas, Inc. info®yingliamericas-com Tal: + 1 (333) 636-8320 Dimensions (L/W/H) Weight Number of modules per pallet Number of pallets per 53' container Packaging box dimensions (UW/H) Box weight Units: inch (mm) 64.76 .n 1650 mmf 38.79 .n 79C mm) 1.31 n ;46 mm) 45.2 bs 205 <g) 22 36 67 m' 1700 mm) - 4 n' 1150 mm) / 47.n '1190 mini 1075 ;bs 188 kg) 3.94 (100) i0.47 (12) / / [t;ECTTON C -C I I / a i i 38 ;35) 1.81 '461 Warning- Read the Installation and User Manual m its antirety before handling, installing, and operating Yingli modules. 1 7ur'acners I The only hlyerta;173 specially designed far dislributed DC archhectu,re Superior efficiency (97.5%) Small, lightweight and easy to install on provided bracket J Built-in module -level monitoring A Communication to internet via Ethernet or Wireless .i Outdoor and indoor installation i Integral AC/DC Switch a c�'C'1Ji°CiS arc I'M PrdVTM 4�£ Yt. x3 ny All our inverters are part of SolarEdge's innovative system designed to provide superior performance at a competitive price. The SolarEdge inverter combines a sophisticated, digital control technology and a one stage, ultra -efficient power conversion architecture to achieve superior performance a CJ4141CAIL DATA Rated AC Power Output Max. AC Power Output I AC Output V01tage Min. -Nom -Max AC FreQuenc -Nom.-Max. Max Continuous Output Current 0208V Max. Continuous Output Current 0240V Max. Continuous Output Current 0277V GFD! Utility Monitoring" Islandin; Protection. Cc Recommended Max, DC Power • (STC) Transformer --less, Ungrounded Max. Inom Votra" Max. Input Current Reverse•Polarity Protection Ground -Fault isolation Detection Maximum Inverter Efficiency CEC weighted Efficiency Nttlme Power Consumption >upoorted Communication Inter* Grid Connection Standards Emissions ROHS AC output conduit size / AWG range DC input conduit size / 4 of strings / AWG range - over 97% efficiency and best -in -class reliability. Our fixed - voltage technology ensures the inverter is always working at its optimal input voltage, regardless of the number of modules or environmental conditions. SE3000A-US SE3800A US SE5000A-us SE6000A-US SE7000A-US 3000I 3800 I 5000 I 52000208V 60000240V Thresholds Yes 4750 60000277V 3000 3800 5000 600002 6000®24040V V 325 0 208V / 350 0 240V / 400 0 277V 12.5 16 ,a 60000277V 183 - 208.229 / 211- 240 - 264 183 - 208 22 1/ 211 244264 60okQ Sensitivity 59.3.60 - 60.5 (HI version 57.60 - 60.5) 14.5 1&3 1 24 25 125 16 21 25 3750 97.8 97.5 52000208V 60000240V 70000277V 52000208V 60000240V 70000277V 277.294 25 25 25 �021�?-A/ 3 98.3 98.3 97 0 208V / 97.50 V240V 97 0 208V / 97.50 240V / 97.50 240V / 98 98 0 277V < 2.5 RS4W_ RS232 EMemet, ftee (0Wj0nW UL1741, IEC -62103 (EN50178), IM42109 Utility -interactive, VDE 012611-1, A54777, RD -1663 , OK 5940, FCC part15 class B, IEC61000£-2. IECsinnnaa Icr•c,ni,r. �,, , 3/4' Dimensions (HxwxD) 18 5L 22 21x12.5x7.5/540x315x191 1 Thresholds Yes 4750 8250 7500 .eight Yes Nei ht with AC/DC Switch 500 325 0 208V / 350 0 240V / 400 0 277V 12.5 16 ,a Yes 60okQ Sensitivity 0717 52000208V 60000240V 70000277V 52000208V 60000240V 70000277V 277.294 25 25 25 �021�?-A/ 3 98.3 98.3 97 0 208V / 97.50 V240V 97 0 208V / 97.50 240V / 97.50 240V / 98 98 0 277V < 2.5 RS4W_ RS232 EMemet, ftee (0Wj0nW UL1741, IEC -62103 (EN50178), IM42109 Utility -interactive, VDE 012611-1, A54777, RD -1663 , OK 5940, FCC part15 class B, IEC61000£-2. IECsinnnaa Icr•c,ni,r. �,, , 3/4' Dimensions (HxwxD) 21 x 12.5 x 7 / 21x12.5x7.5/540x315x191 540x315x172 Dimensions with AC/DC Switch (HxWx0) 30.5 x 12.5 x 7 / 30.5x12.5x7.5/ 775x315x191 775x315x172 .eight 44 7 / 20 2 Nei ht with AC/DC Switch 1.2/23.2 51.2/23.2- 3/4" minimum / 246 AWG W W Vac Hz A A A A W Vdc Vdc Adc 3/4" minimum / 1-2 strings / 24.6 AWG I 21x12.5x7.5/540x315x191 in mm 30.5x12.5x7.5/ 775x315x191 in mm 47.7/21.7 Ib kg 54.7 / 24.7 Ib / kg Noise Natural Convection Min. -Max. Operating Temperature Protection Rating Range < 50 dBA g -13 / -25 (CAN version 40 / 40) r- +140 / +60 'F/ 'C Mdter input x aotrerNEMA 3R "stilled: anahie Yeirly AC mrfamanee. 2' The IW -9 Part '"DWSare a,edahb "CAN Nsars "Old for Uro Ontario RT Wd mleroRTi: '® 208/240. min. ope 19 tamp 4F/ -20C. a-E3000AUS. SE3WO"S. SEWW"S• SE6000A.US. SE7000A.US. SE3000A-USSE380OA-USa/i. sEa-oo"USrN. SE6000A-US-Hl. SE7o00A.USNI 2771/. -.- _ng comp _4F/_20C:SESo00AUS0F. SE6000AUS. SE7000AUS. aE5000A-USMI. SE6000M1S.MI. iE7000A•US1I 208/240V, per ng twmatjn( tamp 4 ()C: C: SE3000A-1SCAN. SE3800A,USCAN. SEa000"SCAN. SE6000AUSCAN 277V, min operayn` comp .4pF/dOC: SESOCOAUSCAN. SE6000A-USCAN. SE70MA-US.CAN s USS, �C"M ny ytaay Panca Japan China Aas-,'adja Iamq wnvw.wlar�s.caiw -s-:•ea •er' ,.. . _.___.-s ..._ - -e,E - __ a :;r . -.-- _-, - ..- __.. S ,__.-_.. - - - 17 _ - ... :-'e -- - - -z-s�scerec -w:a^ants o`So'arEage reennao8,es. enc. VI oNer vademaea MRMV�94, Compa#ibie with ZSP Groove framed modules ?i Certified Zep Compatible'"" bracket Attaches to module frame without screws - reduces on -roof labor and mounting costs _1 Power optimizer equipment grounded through the bracket Up to 25% increase in power output I Superior efficiency (99.5%) - peak performance in both mismatch and unshaded conditions I Flexible system design for maximum space utilization Next generation mainterance with module -level monitoring and smart alerts a Unprecedented installer and firefighter safety `► ,^fir �`�,� fig? 7 , HIGHLIGHTS - Ensures equipment grounding - bond connection with Zap CompatibleTM module Eliminates the need to bolt the optimizer to the rail Module -level MPPT- optimizes each module independently Module -level monitoring for automatic module and string level fault detection allowing for easy maintenance TEJO NI CAL, DATA Maximum MPPT Total Maximum String Voltage (Controlled by Inverter) - US and EU 1 -ph Total Maximum String Voltage (Controlled by Invertert- Pi 2ek Unprecedented installer and firefighter safety mode - safe module voltage when inverter is disconnected or off Allows parallel uneven string length and multi -faceted installations Immediate installation feedback for quick commissioning OP250-LV-Z 1 6P300 -MV Z 250 300 55 I 79 5-55 I 5.75 10 10 98.8 5-60 500 950 Minimum Number of Power Optimizers per String (1 or More Modules per power optimizer) 8 (1 -ph system) / 16 (3 -ph system) Maximum Number of Power Optimizers per String (1 or More Modules per power Optimizer) Module power dependent; maximum 25 (1 -ph system) / 50 (3 -ph system) Maximum Power per Strin 5250 (1 ph system) / 11250 (3 ph system) Parallel Strings of Different Lengths or Orientations Yes EMC FCC Part15 Class 8, IEC61000.6.2, IEC61000-6.3 Safety IEC -62103 (class II safety), UL1741 DMaucrlal i UL -94 (5 -VA), UV Resistant Dimensions includ. mounting bracket (W x L x H) Dimensions exclud. mounting bracket (W x L x H) Net Weight (Weight Inductcables) Output Wire type Output Wire Length nput Connector Relative Humidity I t ) Rated STC power of the module. ,Module of u0 to .5% power tolerance allowed. 137x254x58/5.39x10x2.28 137x139x25.5/5.39x5.47x1.0 0.88 (1.18) / 1.94 (2.6) Double insulated PV wire; 6 MM2; MC4 0.95m/3ft MC4 / Tyco / Amphenol -40 - +65 / -40 - +150 IP67 / NEMA 6 0-100 USA t;�vmarry Jtaiy rfIMI D J.alman Chdina dsvawf W I vdc Vdc Adc Adc Vdc Vdc Vdc sVftdr W mm / in mm / in kg / Ib 'C / °F www-saleredlte.com Sala:r'Mj+" 3rcnitects or anergy Z SolarEdge Technologies, Inc. 20042013. All rights reserved. SOLAREDGE. the SolarEcge rogo, ARCHITECTS OF ENERGY and OPTIMIZES 3Y SDIAREDGE are trademarks or registered trademarks onerxs of SolarEdge Tech•Ologles.' A!! ;tre, trade-3•=:;--..:-3� •e - • 3-� irs Z:1-2. 4J1. S,c,ac to :urge nrthout noc.e. Oatasheet. Z3 coma 2.5 Com- _7 3J= With a series of drop-in and quarter turn connections, ZS Comp offers real Labor savings compared to conventional mounting systems. The structural connections of ZS Comp are auto grounding, eliminating the need for separate grounding hardware. And with its hyper -bonded grounding matrix, ZS Comp offers the safest, most reliable way to ground AV arrays. Dramatically reduces Installation time Eliminates mounting rails and clip hardware Eliminates separate grourding hardware Ultra -reliable hyper -bonded grounding matrix Rapid, top-accessibia,precision array leveling Uttra-iow parts count Enhanced aesthetics TUV tested to IEC 61,215 for 540CPa Load conditions Suitable for high wind applications Interlock ZETL listed to UL i 703 as ground bond means Ground _Zep UL and -_-TL listed to UL 467 as grounding and 'bonding cevice interlock, Hybrid'ntarlock and Ground Zep listed to UL 2703 as PV bonding device ZS Comp mounting hardware is designed for use with Zep Compatible' PV modules from leading PV module Manufacturers. Visit zepsotar.com for a current list Of Zep Compatible- PV modules. ZS Am INZs seam - for• C8%^in 15asI;T :a2.9i 'per 5 ZS Span- (3i1-D2ed ZS Tse e- B Wave - ,.®r �ave- o�7M►�� i ?age .of2 Dadashee4: ZS .10MP Interlock i The Interlock provides nor -h -south and east -west structural and ]round bond connections creating a structurally contiguous hyper -bonded array. Interlock UL listed to UL 1703 and ETL listed to UL;703. Leveling Foot i3t.8mm; , r� 13O. 1.2.Sin f 39.Jmm 1.221 10 in --r I I O l57 2mm j t.5r, n (81.2mm, Z 3.ZOin i.... 4.pdin zo The Leveling root provides a means of attachment oetween the ?V array and the mounting surface or flashep attachment aoparatus and 3lt3ws for easy array heignt adjustment ;1.15' throwf. Comp ,Mount Type C I The Comp Mount Type C provides a means of flashed attachment for composition shingle roofs. Ground Zap r_-- The Ground Zep provides a point of connection between the PV array and the equipment grounding conductor. One Ground Zep is required `or every 72 PV modules. A and ETL listed to UL 461. UL listed to UL 2703. Universal Box Bracket The Universal Box Bracket allows rapid attachment of electricat boxes to the module frame. Alrray Skirt The Array skirt facilitates easy root -row, nstallation while providing alean look at the front of the PV array. AC/RSC Cable Clip 0 Crips into Zep Groove for ultra -fast and easy management of PV wiring and micro -inverter cables. Array Skirt Cap Set The Array Skirt Cap Set provides an aesthetic cover for the exposed ara if the Array Skirt. Made of anodized al:minum. each Set,:omas with two Skirt Caps. This tacument JIM hat leaf@ try exprrs manty ny leo iolit Jr 10a0rn aro0i ct ar ier,,ces. !ea %our. L71e /dlydo[Y iS CWtLOea nl me Mile" Induct Marraily'af nmpro0uct. -he end-user ]oumenianmi;mpped min Zep Solar. pmeoctc roninaales me sold specilicaCans "Iffrea to m rhe aroac: varrantr -he mu:tomer-s safely ,esi on5iale far 'rNll'ylnq the iula0lllly al jep�OlaG ]ra0a[Ia for nEn Jse. )oecincananS ire :ualeCI :o :aange aohout natice..apyrlgni D 1010 _91:,ep ;alar. inc J. ?alem :IS91.i.i1 J.i. atenf9.109.049.J.5.1Int Ipatent$pending . taslJoda(eMarcna.;013'S9PM Comp Mount Zep Tool: 4 functions,1 tooC Flat loot: Forinter-module removal. lI:,I teosabi:om`or. nor e miormauan JOau I fur 7roduc,ono :Dmpinv Page 2 of 2