HomeMy WebLinkAbout39491-zTown of Southold P.O. Box 1179 53095 Main Rd Southold, New York 11971 CERTIFICATE OF OCCUPANCY 5/14/2015 No: 37559 Date: 5/14/2015 THIS CERTIFIES that the building DECK Location of Property: SCTM #: 473889 Subdivision: 3360 Minnehaha Blvd, Southold Sec/Block/Lot: 87.-3-66.4 Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 1/8/2015 pursuant to which Building Permit No. 39491 dated 1/15/2015 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: DECK ADDITION TO AN EXISTING ONE FAMILY DWELLING AS PER ZBA DECISION #6804 DATED 11-20-2-2014, AS APPLIED FOR The certificate is issued to McCoyd, Sean & McCoyd, Jennifer of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. PLUMBERS CERTIFICATION DATED X190' rize Signature TOWN OF SOUTHOLD 7py' o BUILDING DEPARTMENT TOWN CLERK'S OFFICE o • SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit #: 39491 Permission is hereby granted to: McCoyd, Sean & McCoyd, Jennifer 65 Kenwood Rd Garden City. NY 11530 Date: 1/15/2015 To: construct a deck addition per ZBA #6804 and Trustees #8059 as applied for At premises located at: 3360 Minnehaha Blvd SCTM # 473889 Sec/Block/Lot # 87.-3-66.4 Pursuant to application dated 1/8/2015 To expire on Fees: 7/16/2016. and approved by the Building Inspector. SINGLE FAMILY DWELLING - ADDITION OR ALTERATION $315.20 CO - ADDITION TO DWELLING $50.00 Flood Permit $100.00 Total: $465.20 Building Inspector Form No. 6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings, property lines, streets, and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage -disposal (S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead. 5. Commercial building, industrial building, multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings (prior to April 9, 1957) non -conforming uses, or buildings and "pre-existing" land uses: 1. Accurate survey of property showing all property lines, streets, building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied, the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy - New dwelling $50.00, Additions to dwelling $50.00, Alterations to dwelling $50.00, Swimming pool $50.00, Accessory building $50.00, Additions to accessory building $50.00, Businesses $50.00. 2. Certificate of Occupancy on Pre-existing Building - $100.00 3. Copy of Certificate of Occupancy - $.25 4. Updated Certificate of Occupancy - $50.00 5. Temporary Certificate of Occupancy - Residential $15.00, Commercial $15.00 /Date. ( '!�;- — I T New Construction: Old or Pre-existing Building: ✓ (check one) Location of Property: 3 3 iep M wra p (Y \16( . !9a-5V`OkA WA t 1 �, 1 House No. Street AA Hamlet Owner or Owners of Property: - Sea-, + ',S -ext,, -'4, Clic pp� Suffolk County Tax Map No 1000, Section Fi Block Lot Co (® Subdivision' r Filed Map. Lot: Permit No. 9 `'( L Date of Permit. Applicant: t%�`{� ` Health Dept. Approval: Underwriters Approval: Planning Board Approval: Request for: Temporary Certificate Final Certificate: (check one) t9'U Fee Submitted: $ Applicant Signature i Of SO(/lyolo r yeou TOWN OF SOUTHOLD-BUILDINGDEPT:: 765-1802 1NSPE-CT1ON [ VrFOUNDATION IST [ ] ROUGH PLUMBING [ ] FOUNDATION 2ND [ ] INSULATION- NSULATIONFRAMING/ FRAMING/STRAPPING [ ] FINAL [ ] FIREPLACE A CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] CAULKING REMARKS: C DATE- � INSPECTOR rjf so roun TOWN OF SOUTHOLD BUILDING" DEPT. 765-1802, ''IN-SPECTION-' .1 FOUNDATION I -ST ROUGH'PLUMBING FOUNDATION 2ND INSU ON-. ]FRAMING/ STRAPPING, NAL FIREPLACE& CHIMNEY ']FIRE SAFETY INSPECTION FIRE RESISTANT CONSTRUCTION FIRE RESISTANT PENETRATION ELECTRICAL (ROUGH) ELECTRICAL (FINAL) CODE VIOLATION CAULKING RIEMARKS! DATE'. Examined 20-r� Approved J 20 1 S Disapproved a/c Expiration _4120 Trustees C.O. Application Flood Permit Single & Separate Storm -Water Assessment Form Contact: �ecz� 1—\GQ'Qyct� n Mail to: �Sy� e ,..�ev� `A Building Inspector APPLICATION FOR BUILDING PERMIT INSTRUCTIONS e, � r� , ,�.ci •_� r iso .� a, IX �I JAN -72015 I BLDG DEPT. TOWN OF SOUTHOLD Date 1 — !E� , 20_/ a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans, accurate plot plan to scale. Fee according to schedule. b. Plot plan showing location of lot and of buildings on premises, relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application, the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e. No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim, the Building Inspector may authorize, in writing, the extension of the permit for an addition six months. Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County, New York, and other applicable Laws, Ordinances or Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances, building code, housing code, and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. (Signature of applicant or name, if a corporation) 65- A . ,wa):Q (2j_ 6..r� qii'l 01( 1(S 3" (Mailing address of applicant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder Name of owner of premises 0—L (A's on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer (Name and title of corporate officer) Builders License No, A]/A- Plumbers License No. PlAr John M. Bredemeyer III. President Michael J. Domino, Vice -President James F. King, Trustee Dave Bergen, Trustee Charles J. Sanders, Trustee December 17, 2014 Southold, NY 11971v BOARD OF TOWN TRUSTEES TOWN OF SOUTHOLD RE: SEAN MCCOYD 3360 MINNEHAHA BOULEVARD, SOUTHOLD SCTM# 87-3-66.4 Dear Mr. McCoyd: Town Hall Annex 54375 Main Road P.O. Box 1179 Southold, New York 11971-0959 Telephone (631) 765-1892 Fax (631) 765-6641 The following. action was taken by the Southold Town Board of Trustees at their Regular Meeting held on Wednesday, December 17,2014: RESOLVED, that the Southold Town Board of Trustees APPROVES the Administrative Amendment to Wetland Permit #8059 to remove existing brick patio and construct a 12'x24' wood deck with stairs; and as depicted on the revised project plan prepared by Sean McCoyd, received on August 18, 2014 and stamped approved on December 17, 2014. Any other activity within 100' of the wetland boundary requires a permit from this office. This is not a determination from any other agency. If have You any questions, please call our office at 631 765-1892. Sincerely, John M. Bredemeyer III President, Board of Trustees JMB:amn John M. Bredemeyer III, President Michael J. Domino, Vice -President .James F. King, Trustee Dave Bergen, Trustee Charles J. Sanders, Trustee # 1114C BOARD OF TOWN TRUSTEES TOWN OF SOUTHOLD Town Hall Annex 54375 Main Road P.O. Box 1179 Southold, New York 11971-0959 CERTIFICATE OF COMPLIANCE Telephone (631) 765-1892 Fax (631) 765-6641 Date: May 12, 2015 THIS CERTIFIES that the elevation of existing single-family dwelling (9.0') and garage (8.0') and the depositing// rg ading of clean fill (115cy.); gutters to leaders to dr wells At 3360 Minnehaha Boulevard, Southold, New York Suffolk County Tax Map # 87-3-66.4 Conforms to the application for a Trustees Permit heretofore filed in this office Dated January 30, 2013 pursuant to which Trustees Wetland Permit #8059 Dated February 20, 2013, was issued and conforms to all of the requirements and conditions of the applicable provisions of law. The project for which this certificate is being issued is for the elevation of existing single-family dwelling(_9.0')and garage (8.0') and the depositing/grading of clean fill (115cy.); gutters to leaders to dawells. The certificate is issued to SEAN R. MCCOYD owner of the aforesaid property. Authorized Signature New York State Department of Environmental Conservation Division of Environmental Permits, Region 1 SUNY @ Stony Brook 50 Circle Road, Stony Brook, NY 11790-3409 Phone: (631) 444-0365 • Fax: (631) 444-0360 Website: www.dec.ny.4ov LETTER OF NO JURISDICTION Sean McCoyd February 20, 2013 65 Kenwood Road Garden City, NY 11530 Re: Application #1-4738-04206/00001 McCoyd Property, 3360 Minnehaha Blvd., Southold SCTM# 1000-87.-3-66.4 Dear Sirs or Madams: Based on the information you submitted the Department of Environmental Conservation has determined that the existing bulkhead is functional, more than 100 feet in length and was constructed before August 20;1977. Therefore, the property landward of the bulkhead is beyond Tidal Wetlands Act (Article 25) jurisdiction and no permit is required for work landward of this structure: Be advised, no construction, sedimentation; or disturbance of any kind may take place*seaward of the tidal wetlands jurisdictional boundary, as indicated above, without a permit. It is your responsibility to ensure that all precautions are taken to prevent any sedimentation or disturbance within Article 25 jurisdiction which may result from your project. Such precautions may include maintaining adequate work area between the jurisdictional boundary and your project (i.e. a 15' wide construction area) or erecting a temporary fence, barrier, or hale bay berm. This letter shall remain valid unless site conditions change. Please. note that this letter does not relieve you of the responsibility of obtaining any necessary permits or approvals from other agencies or local municipalities. Sincerely, Rog Evans Regi nal Permit Administrator cc: 'Suffolk Environmental. Consulting, Inc. BOH -TW File FORM NO. 3 NOTICE OF DISAPPROVAL DATE: May 1, 2013 TO: Suffolk Environmental Consulting for S. McCoyd P O Box 2003 Bridgehampton, NY 11932 Please take notice that your application dated April 23, 2013 For permit for a deck addition to an existing dwelling at Location of property 3360 Minihaha Blvd., Southold, NY County Tax Map No. 1000 - Section 87 _Block 3 Lot 66.4 Is returned herewith and disapproved on the following grounds: The proposed deck addition is not permitted pursuant to Article XXII, Section 280-116B, "All buildings or structures located on lots upon which a bulkhead... exists... shall be set back not less than 75' from the bulkhead." The site plan indicates a setback from the bulkhead of approx. 28.7'. 2 Permit Examiner BOARD MEMBERS Leslie Kanes Weisman, Chairperson Eric Dantes Gerard P. Goehringer George Horning Kenneth Schneider OF SO(/�y® � O COO O '® a@ �counm,� http://southoldtown.northfork.net Southold Town Hall 53095 Main Road • P.O. Box 1179 Southold, NY 11971-0959 Office Location: Town Annex /First Floor, Capital One Bank 54375 Main Road (at Youngs Avenue) Southold, NY 11971 L� ZONING BOARD OF APPEALS i.. NOV 2 5 2014 TOWN OF SOUTHOLD r Tel. (631) 765-1809 • Fax (631) 765-9064 J R� fir. DEPT. Into FINDINGS, DELIBERATIONS AND DETERMINATION MEETING OF NOVEMBER 20, 2014 ZBA FILE # 6804 NAME OF APPLICANT: Sean McCoyd SCTM# 1000-87-3-66.4 PROPERTY LOCATION: 3360 Minnehaha Boulevard (adj. to Corey Creek), Southold, NY SEQRA DETERMINATION: The Zoning Board of Appeals has visited the property under consideration in this application and determines that this review falls under the Type II category of the State's List of Actions, without further steps under SEQRA. SUFFOLK COUNTY ADMINISTRATIVE CODE: This application was referred as required under the Suffolk County Administrative Code Sections A 14-14 to 23, and the Suffolk County Department of Planning issued its reply dated October 30, 2014 stating that this application is considered a matter for local determination as there appears to be no significant county -wide or inter -community impact. LWRP DETERMINATION: This application was referred for review under Chapter 268, Waterfront Consistency Review of the Town of Southold Town Code and the Local Waterfront Revitalization Program (LWRP) Policy Standards. The LWRP Coordinator issued a recommendation dated October 24, 2014. Based upon the information provided on the LWRP Consistency Assessment Form submitted to this department, as well as the records available to us, it is our recommendation that the proposed action is CONSISTENT with LWRP policy standards and therefore is CONSISTENT with the LWRP. PROPERTY FACTS/DESCRIPTION: The parcel is a non -conforming 9,673 square foot water front parcel located in an R-40 zone. The parcel is developed with 1 story frame house and garage. The property has 132.42 feet along Corey Creek. The property then runs 105.37 feet along the East side, 109.75 feet along Minnehaha Blvd. and 89.23 feet along the West side. There is a dock, ramp, and floating dock on Corey Creek. A small section of the front yard is in Flood Zone X. The majority of the property is in Flood Zone AE El. 6. The survey shows that there is a proposed line of hay bales set back 15 feet from the concrete wall. The existing house is set back 35 feet from the concrete wall. All is shown on a survey by John T Metzger L.L.S. dated December 19, 2012 and last updated September 18, 2014. BASIS OF APPLICATION: Request for Variance from Article XXII Section 280-116B and the Building Inspector's September 30, 2014 Notice of Disapproval based on an application for building permit to construct a deck addition to an existing single family dwelling, at; 1) less than the code required bulkhead setback of 75 feet. RELIEF REQUESTED: The applicant requests a variance to construct a raised deck set back 29 feet from the concrete wall, where the code requires a 75 foot bulkhead setback. Page 2 of 3 — November 20, 2014 ZBA#6804 — McCoyd SCTM#1000-87-3-66.4 ADDITIONAL INFORMATION: The applicant submitted (4) letters in support of his application. The applicant also presented four prior Zoning Board of Appeals decisions granting variances for raised decks on Minnehaha Blvd. These decks have similar bulkhead/concrete wall setbacks to the concrete wall setback being requested by the applicant. The variances are ZBA file No.'s 3937; 4973; 5028; and 5065. FINDINGS OF FACT/ REASONS FOR BOARD ACTION: The Zoning Board of Appeals held a public hearing on this application on November 6, 2014 at which time written and oral evidence were presented. Based upon all testimony, documentation, personal inspection of the property and surrounding neighborhood, and other evidence, the Zoning Board finds the following facts to be true and relevant and makes the following findings: 1. Town Law 4267-b(3)(b)(1). Grant of the variance will not produce an undesirable change in the character of the neighborhood or a detriment to nearby properties. The neighborhood consists of modest single-family homes. Rear decks are common in the neighborhood. The deck is in the rear of the house and will not be seen from the street. Existing vegetation will limit the adjoining neighbor's view of the deck. 2. Town Law X267-b(3)(b)(2). The benefit sought by the applicant cannot be achieved by some method, feasible for the applicant to pursue, other than an area variance. The lot size and current configuration of the house is such that any expansion of the house will require a variance. 3. Town Law §267-b(3)(b)(3). The variance granted herein is mathematically substantial, representing 62% relief from the code. However, the existing home is set back 35 feet from the concrete wall. The new raised deck is only six feet closer to the concrete wall than the house already sits. 4. Town ..Law.._267-b(3)(b)(4)_No...evidence has been submitted to suggest that a variance in this residential community will have an adverse impact on the physical or environmental conditions in the neighborhood. The applicant must comply with Chapter 236 of the Town's Storm Water Management Code and all storm water management will be in place during construction and the deck will be open to the sky. 5. Town Law §267-b(3)(b)(5). The difficulty has been self-created. The applicant purchased the parcel after the Zoning Code was in effect and it is presumed that the applicant had actual or constructive knowledge of the limitations on the use of the parcel under the Zoning Code in effect prior to or at the time of purchase. 6. Town Law X267 -b. Grant of the requested relief is the minimum action necessary and adequate to enable the applicant to enjoy the benefit of a raised deck while preserving and protecting the character of the neighborhood and the health, safety and welfare of the community. RESOLUTION OF THE BOARD: In considering all of the above factors and applying the balancing test under New York Town Law 267-B, motion was offered by Member Dantes, seconded by Member Schneider, and duly carried, to GRANT, the variance as applied for, and shown on the Architectural Drawings by Barbara M. Ruggiero, Architect labeled A-01, 02 and dated September 30, 2014 and the site plan by John T. Metzger L.L.S. dated December 19, 2012, last revised September 18, 2014. Subject to the following condition; CONDITION: 1) The deck shall remain open to the sky. That the above conditions be written into the Building Inspector's Certificate of Occupancy, when issued. Page 3 of 3—November 20, 2014 ZBA#6804 — McCoyd SCTM#1000-87-3-66.4 Any deviation from the survey, site plan and/or architectural drawings cited in this decision will result in delays and/or a possible denial by the Building Department of a building permit, and may require a new application and public hearing before the Zoning Board of Appeals. Any deviation from the variance(s) granted herein as shown on the architectural drawings, site plan and/or survey cited above, such as alterations, extensions, or demolitions, are not authorized under this application when involving nonconformities under the zoning code. This action does not authorize or condone any current or future use, setback or other feature of the subject property that may violate the Zoning Code, other than such uses, setbacks and other features as are expressly addressed in this action. The Board reserves the right to substitute a similar design that is de minimis in nature for an alteration that does not increase the degree of nonconformity. Vote of the Board.• Ayes: Members Weisman (Chairperson), Schneider, Horning, Dantes. (Absent was: Member Goehringer) This Resolution was duly adopted (4-0). l Leslie Kanes Weisman, Chairperson Approved for filing/ /—/2014 �:;COtt A. iL1 SSE11 ' ��` '/// �a.`�':, 0 1t. kU)JC1k �\Vai \V\v CW A JL. ALN,& 1 -, r`t �S SUPERVISOR } ��/]CA\1NA\(G IEMIENT SOUTHOLD TOWN HALL- P. O. Box 1179-. 53095 Main Road - SOUTHOLD, NEW YORK 11971 ti 'own of Southold �C,- 'f j, '--.—(-�' �^ ��1.�22i:CC1 CHAPTER 236 r- STORMWATER MANAGEMENT WORK SKEET ( TO BE COMPLETED BY THE APPLICANT) i DOLES THIS IPROJIECr INVOLVE ANY OF T)i-111E FOLLOW,INc: (CHECK ALL THAT APPLE Yes Nq • F1 A. Clearing, grubbing, grading or stripping of land which affects more } than 5,000 square feet of ground surface. D Excavation or filling involving more than 200 cubic yards of material within any parcel or any contiguous area. -_ 1c2:')n2s whichercee l 1� feet vea iciil l'ise to 100 feet of horizontal distance. Q RdD. Site preparation within 100 feet of wetlands, beach, bluff or coastal erosion hazard area. E E. Site preparation within the one -hundred -year floodplain as depicted on FIRM Map of any watercourse. []Q'F. Installation of new or resurfaced impervious surfaces of 1,000 square feet or more, unless prior approval of a Stormwater Management Control Plan was received by the Town and the proposal includes , in-kind replacement of impervious surfaces. If you answered NO to all of the questions above, STOP! Complete the Applicant section below with your Name, Signature, Contact Information, Date & County Tax Map Number! Chapter 236 does not apply to your project. T =�= w If you answered YES to one or more of the above, please submit Two copies of a Stormwater Management Control Plan and a completed Check List Form to the Building Department with your Building Permit Application. APPLICANT: (Property Owner, Design Professional, Agent, Contractor, Other) NAME: Prw) ,lOi(gn���lu�rr%l Contact Informal ion: ,� rky�P'grsr,^vmnlKb Property Address / Location of Construction Work:33 F'ORNI " SN/lCP - TOS MAY 2014 S.C.T.M. 1000 bate: Oun icl q 5ectton Rlock Lot FOR BUILDING DEPARTNIENT USE Reviewed By: — �?��/QCA_ _ Date: Approved for pi rQ=sing Building Permit. Stormwater Management Control Plan Not Required. Stormwater Managenwrit Control Plan is Required. (Forward to Engineering Department for Review.) PLICANT: ryerty Ovmer, Design ProFessiooal, Agent, Contractor. OtAer? n -res SP1z� C�-o �l SME: � S.C.T.M. 1000 � Section Block Lot s ;Q �4 !C� � � ) '-'� ` �1i� CHAPTER 236 Stormwater Alanagement Control Plan CHECK LIST S M C P -Pian Requirements: Provide ONE copy of the Building Permit Application. The applicant must provide a Complete Explanation and/or Reason for not providing all Information that has been Required by the following Checklist! - wggt Tdt�nne Nwotr , Date i / — S / i i 1 A Site Plan drawn to scale Not Less that 69 to the inch MU show all of the following items If You answered No or NA to any Item, Please Provide Justification Here 1l NO NA If you need additional room for explanations, PIease Provide additional Paper, a. Location & Description of Property Boundaries b. Total Site Acreage. c. Existing - Natural & Man Made Features within 500 L.F. of the Site Boundary as required by 9236-1702). f d. Test Hole Data Indicating Soil Characteristics & Depth to Ground Water. e. Limits of Clearing &Area of Proposed Land Disturbance. f. Existing & Proposed Contours of the Site (Minimum 2 Intervals) g. Location of all existing & proposed structures, roads, driveways, sidewalks, drainage improvements & utilities. j `0 h. Spot Grades & Finish Floor Elevations for all existing & proposed structures. 1. Location of proposed Swimming Pool and discharge ring. j. Location of proposed Soil Stockpile Area(s). k. Location of proposed Construction Entrance/Staging Area(s). 1. Location of proposed concrete washout area(s). m. Location of all proposed erosion & sediment control measures. Stormwater Management Control Plan must include Calculations showing that the stormwater Improvements are sized to capture, store, and Infiltrate on-site the run-off from all impervious surfaces generated by a two (7) inch rainfall / storm event. Details & Sectional Drawings for stormwater practices are required for approval Items requiring details shall include but not be limited to: a. Erosion & Sediment Controls. b. Construction Entrance & Site Access. c. Inlet Drainage Structures (e.g. catch basins, trench drains, etc.) d. Leaching Structures (e.g. infiltration basins, swales, etc.) �( il r FOR ENGINEERING DEPARTMENT USE ONLYF� Reviewed & Approved By: Date: 1 Additional Information is Required. I Storrriwater Management Control Plan is Not Complete, ( ———————————————————————- Storm!vater Management Control Plan is Complete. ( SMCP has been approved by the Engineering i)ennrtmPnt RM " SWCP Check List - TOS MAY 2014 APPLICATION PAGE 1 0( 4 — TOWN OF SOUTHOLD FLOODPLAIN DEVELOPMENT PERMIT APPLICATION This form is to be filled out in duplicate. SECTION 1 GENERAL PROVISIONS (APPLICANT to read and S40) 1. No work may start until a permit is issued. 2_ The permit may be revoked if any false statements are made herein_ 3. If revoked, all work must cease until permit is re -issued. 4. Development shall not be used or occupied until a Certificate of Compliance is issued. S. The permit will expire if no work is commenced within six months of issuance. b. Applicant is hereby informed that other permits may be required to fulfill local, state and federal regulatory requirements. 7. Applicant hereby gives consent to the Local Administrator or his/her representative to make reasonable inspections required to verify compliance_ 8. I, THE APPLICANT, CERTIFY THAT ALL STATEMENTS HEREIN AND IN ATTACHMENTS TO _ THIS APPLICATION ARE, TO THE BEST OFMY ONYLEDGE, TRUE AND ACCURATE. (APPLICANT'S Sf(,*ATURE) + � DATE SECTION 2: PROPOSED DALOPMENT (Tb be completed by APPLICAIr'il NAME ADDRESS TELEPHONE CS" t (.) (o(10 91 st APPLICANT BUILDER ENGINEER i PROJECT LO=Ot l: To avoid delay is processing the application. please provide enough information to easily identify the project location. Provide the street address, lot number or legal description (attach) and, outside urban areas, the distance to the nearest intersecting road or well-known landmark- A sketch attached to this application showing the project location would be helpful. c.lba (J i' %, 1,0-- A-0 FDP(93) I)czC4 r oa___C C ..L _LU iL IL4 A-PPLICATION PAGE 2 OF d DESCRIPTION OF WORK (Check all appbcabfc boxes): A. STRUCTURAL DEVELOPMENT ACTIVITY STRUCTURE. TYPE, ❑ New Structure R Residential (1-4 Family) VAddition ❑ Residential (More than 4 Family) ❑ Alteration ❑ Non-residential (FloodprooTtng? ❑ Yes) ❑ Relocation ❑ Combined Use (Residential & Commercial) ❑ Demolition P ❑ Manufactured (Mobile) Home (In Manu - 0 Replacement factured Home Park? ❑ Yes) ESTIMATED COST OF PROJECT S 14S00 - 4zf� B. OTHER DEVELOPMENT ACTIVITIES: ❑ Fill ❑ Mining ❑ Drilling ❑ Grading ❑ Excavation (Except for Structural Development Checked Above) ❑ Watercourse Alteration (Including Dredging and Channel Modifications) O Drainage Improv ments .(induding Culvert Work) ❑ Road, Street or Bridge Construction ❑ Subdivision (New or Expansion) ❑ Individual Water or Sbsr System c ❑ Other (Please Spect7y)' After completing SECTION 2, APPLICANT' should submit form to Local Administrator for review- ECTION 3: DPLAIN DETERMINATION Clo be completed by LOCAI, ADNfINISTRATORI The proposed development is located on FIRM Panel No. Dated The, Proposed Development: O Is N= located in a Special Flood Hazard Area (Notify the applicant that the application review is complete and NO FLOODPLAIN DEVELOPMENT PERMIT IS REQUIRED). 0 Is Iocated in a Spedal Flood Hazard Area. FIRM zone designation is 100 -Year elevation at the site is: Ft. NGVD (MSL) ar fl ❑ Unavailable ❑ The proposed development is located in a floodway. FBFM Panel No. Dated_ ❑ See Section 4 for addition I instructions. SIGNED DATE AYI'1_11...A 1 1VIv u PAGE 3 OF a SECTIO 4 ADDfTi01lAL INFORMATION REQUIRED fTo he comnleted by LOCAL ADMINISTRATORI The applicant must submit the documents checked below before the application can be processed: ❑ A site plan sbowing the location of all c;dsting structures, water bodies, adjacent roads, lot dimensions and proposed development. ❑ Devclopmen( plans, drawn to scale, and specifications, including wbere applicable: details for anchoring structures, proposed elevation of lowest floor (including basement), types of water resistant materials used below the first floor, details of floodproof-ing of utilities located below the first floor and details of enclosures below the fust floor. Also ❑ Subdivision or other development plans .(If the subdivision or other development exceeds 50 lots or 5 ages, whichever is the lesser, the applicant must provide 100 -year flood elevations if they arc not otherwise available). ❑ Plans showing the extent of watercourse relocation and/or landform alterations. ❑ Top of new fill elevation Ft. MGVD (MSL). ❑ Floodproofing protection level (non-residential only) Ft.' MGVD (MSL). For <r_. �. floc, Proofed structures, applicant must attach certification from registered engineer or architect. ❑ Certificatio '7rom a registered engineer that the proposed activity in a regulatory floodway will not result in any increase in the height of the 100 -year flood. A copy of all data and calculations supporting�t is finding must also be submitted_ ❑ Ocher: SECTION 5 PERMIT DETERMINATION (To be completed by WCAL ADMINISTRATORI I have determined that the proposed activity. A. O Is B. ❑ Is not • in conformance with provisions of Local Law # , 19 The permit is issued subject to the conditions attached to and made part of this permit. SIGNED DATE If BOX A is checked, the Local Administrator may issue a Development Permit upon payment of designated fee. If BOX B is checked, the Local Administrator will provide a written summary of deficiencies. Applicant may revise and resubmit an application to the Local Administrator or may request a hearing from the Board of Appeals. TOWN OF SOUTHOLD CERTIFICATE OF COMPLIANCE FOR DEVELOPMENT IN A SPECIAL FLOOD HA -kRD AREA (O" ER MUST RETAIN THIS CERTIFICATE) PREMISES LOCATED AT: PERMIT NO. PERMIT DATE OWNERS NAME AND DRESS: CHECK ONE: _ ❑ BUILDING co� "� -w" O'� STING BUILDING �. 04 m53� ❑ VACANT LAND THE LOCAL ADMINISTRATOR IS TO COMPLETE A. OR B. BELOW: A. COMPLIANCE IS HE, CERTIFIED WITH THE REQUIREMENTS OF LOCAL LAW # , 19 SIGNED: DATED: B. COMPLIANCE IS HEREBY CERTIFIED WITH THE REQUIREMENTS OF LOCAL LAW # , I9_1 AS MODIFIED BY VARIANCE # , DATED SIGNED: DATED: C/C(93) APPEALS: Appealed to Board of Appeals? ❑ Ycs Hearing date: Appeals Board Decision --- Approved? ❑ No ❑ Ycs ❑ No APPLICATION y _ PAGE a Or- a Conditions SECTION 6: AS -BUILT ELEVATIONS (To be submitted by APPLICANT before Certificate of Compliance is issued The following information must be provided for project structures_ This section must be completed by a registered professional engineer or a Licensed land surveyor (or attach a certification to this application). Complete 1 or 2 below. 1. Actual (As -Built) Elevation of the top of the lowest floor, including basement (in Coastal High Hazard Areas, bottom of lowest structural member of the lowest floor, excluding piling and columns) is: Fr. NGVD (MSL). 2. Actual (As -Built) Elevation of floodproofmg protection is FT. NGVD (MSL)" NOTE: Any work performed prior to submittal of the above information is at the risk of the Applicant. SECTION 7 COMPLIANCE ACTION (To be completed by LOCAL ADMINISTRATOR) The LOCAL ADMINISTRATOR will complete this section as applicable based on- inspection of the project to ensure compliance with the community's local law for flood damage prevention. INSPtCTIONS: DATE BY DEFICIENCIES? DYES ONO DATE BY DEFICIENCIES? 0 YES ❑ NO DATE BY DEFICIENCIES? O YES 0 NO SECTION 8 CERTIFICATE OF COMPLIANCEC!o be completed by LOCAL ADMINISTRATOR) . Certificate of Compliance issued: DATE BY: Suffolk Environmental Consulting, Inc. Newman Village, Suite E, 2322 Main Street, P.O. Box 2003, Bridgehampton, New York 11932-2003 (631) 537-5160 Fax: (631) 537-5291 Bruce Anderson, M.S., President Hand Delivered April 22, 2013 Ms. Pat Conklin Southold Town Building Department P.O. Box 1179 Southold, NY 11971 Re: McCoyd Property Situate: 3360 Minihaha Boulevard, Southold, NY SCTM #: 1000 — 87 — 03 — 66.4 Dear Ms. Conklin, This Firm represents Mr. Sean McCoyd, owner of the above referenced property, who is seeking all regulatory approvals to further improve thereon. Unfortunately, the proposed activity is non -conforming with respect to current zoning. Consequently, variance relief will be required, and therefore, a letter of disapproval is requested from your office. Enclosed herewith for your review please find: (1) Town of Southold Building Permit application; (2) Survey of subject property, as prepared by Peconic Surveyors, P.C., last dated April 4, 2013, indicating all existing and proposed structures thereon; and (3) Check in the amount of $ 50.00 to cover the administrative fee concerning this matter. By way of this correspondence, and on behalf of Mr. McCoyd, kindly forward to this office a letter of denial concerning this project. Should you have any questions regarding this matter, please feel free to contact this office at any time. Thank you in advance for your attention and consideration. Sincerely, James F. aird enc. CC: S. McCoyd Town Hall Annex 54375 Main Road P.O. Box 1179 Southold, NY 11971-0959 May 4, 2015 Sean McCoyd 65 Kenwood Rd Garden City NY 11530 BUILDING DEPARTMENT TOWN OF SOUTHOLD Re: 3360 Minnehaha Blvd, Southold TO WHOM IT MAY CONCERN: The Following Items (if Checked) Are Needed To Complete Your Certificate of Occupancy: Application for Certificate of Occupancy. (Enclosed) Electrical Underwriters Certificate. A fee of $50.00. Final Health Department Approval. Plumbers Solder Certificate. (All permits involving plumbing after 4/1/84) Trustees Certificate of Compliance. (Town Trustees # 765-1892) Final Planning Board Approval. (Planning # 765-1938) Final Fire Inspection from Fire Marshall. Final Landmark Preservation approval. Final inspection by Building Dept. Final Storm Water Runoff Approval from Town Engineer BUILDING PERMIT — 39491 — Deck Addition Telephone (631) 765-1802 Fax (631) 765-9502 EXISTING BRICK PATIO 8 RLAR ENTRY STOOP TO BE REMOVED TEST HOLE DATA BY McDONALD GEOSCIENCE 12/6/12 EL 4.6' DARK BROWN LOAM OL ---- 0.5' BROWN SILTY SAND SM ----- 4' BROWN CLAYEY SAND SC EL -0.1' ----- 4.7' WATER WATER IN BROWN CLAYEY SAND SC ----- 7' WATER IN PALE BROWN FINE TO MEDIUM SAND SP 17' N6�23O b N89046'07"E 6.39' TIE 60 -.4 ivgTFR //V, '&O sTRFFT� MF qN ti�cH y�P ELEVATIONS REFERENCED TO N.A.V.D. 4 SURVEY OF PROPERTY A T LA UGHING WATERS TO WN OF SO UTHOLD SUFFO.W COUNTY, N. Y. - 1000-87-03-66.4 SCALE,- ,1'=30' DECEMBER 19, 2012 JAN. 25, 2013 (addiKons) JAN. '29, 2013,fadd flons) FEB. 21, 2013 (addlfions) APRIL 4, 2013. -(PROP. DECK) PROPOSED FILL 115 CU. YDS FILL O PROPOSED CMT01 eFr 1i.O.USE) TO BE ELEVATED - Flx Fir.. el _GARAGE TO BE ELEVATED - FIn. Fir- el.' S' RAIN RUNOFF .CONTAINMENT HOUSE & GARAGE - 1371 sq.1t. , 1371 x I x 0.17 - 233 cult. 233122.3 =10.4 VF PROVIDE 3 DWS - 6'0 x 3.5' DEEP OR EQUAL DWs TO BE CONNECTED BY LEADERS &.GUTTERS I am familiar with the STANDARDS FOR APPROVAL AND CONSTRUCTION OF SUBSURFACE SEWAGE DISPOSAL SYSTEMS FOR SINGLE FAMILY RESIDENCES and will abide by the conditions set forth therein and on the permit to construct. The location of weHs,cesspools & public water shown hereon are from fiefe� ' s and or from data obtained from others. FLOOD ZONE FROM FIRM MAP NUMBER 36103CO166H SEPTEMBER 25, 2000 . ANY ALTERA77ON OR ADDITION TO THIS SURVEY IS A VIOLATION OF SEC77ON 72090F 7HE NEW YORK STATE EDUCATION LAW. EXCEPT AS PER SECTION 7209—SUBDIVISION 2. ALL CERTIFI0A77ONS HEREON ARE VALID FOR THIS MAP AND COPIES THEREOF ONLY IF SAID MAP OR COPIES BEAR 77 -IE IMPRESSED SEAL OF THE SURVEYOR WHOSE SIGNATURE APPEARS HEREON. �t. ME���' 'eg- N. Y S LIC. NO. 49618 ECONIC VEYORS, P.C. 409J (631) 765-5020 FAX (631) 765-1797, LAS P. 0. BOX 909 SOUTH L,6-' MY ER 11971 T 112-305 EXISTING BRICK PATIO & REAR ENTRY STOOP TO BE REMOVED �G �G 9 LOT COVERAGE UPLAND AREA 9673 sq.lt. HOUSE d DECKS - 1756 sq.lt. 1756/9673 18.4 10 TEST HOLE DATA BY McDONALD GEOSCIENCE 12/6/12 EL 4.6' DARK BROWN LOAM OL ----- 0.5' BROWN SILTY SAND SM BROWN CLAYEY SAND SC EL -0.1.' WATER 4.7' WATER IN BROWN CLAYEY SAND SC -- 7' WATER IN PALE BROWN FINE TO MEDIUM SAND SP 17' X61•\23 Opp N89'46'07"E 6.39' TIE FFTJ SURVEY OF- PROPERTY A T LAUGHING WATERS TOWN OF SO UTHOLD SUFF04K COUNTY, N. Y. 1000-87-03-66.4 SCALE: 1'=30' DECEMBER 19, 2012 JAN. 25, 2013 (additions) JAN. 29, 2013 (additions) FEB. 21, 2013 (ad(Olions) APRIL 4, 2013 (PROP. DECK) SEPT. 10, 2013 .(PROPERTY MARKERSJ Bldg Dept copy from ZBA SEPT. 18, 2014 (REVISIONS) Final reviewed documents ZBA Fi # �f` Date: / /a R El (�go� VED OCT 0-.1 2014 PROPOSED FILL BOAR® OF APPEALS 115 CU YDS FILL p. Pwpasm cwrow HOC/FSE' TO BE ELEVATED - Fin. Fir.. e12•. GARAdE TO 13E ELEVATED - Fin. Flr. el. 8` RAIN RUNOFF .CONTAINMENT HOUSE & GARAGE - 1371 sq.ft. 1371 x I x 0.17 = 233 cot. . 233122.3 -10.5 VF -PROVIDE 3 DWS - "6'0 x 3.5' "DEEP OR EQUAL DWs TO BE CONNECTED BY LEADERS & GUTTERS I am familiar with the STANDARDS FOR APPROVAL AND CONSTRUCTION OF SUBSURFACE SEWAGE DISPOSAL SYSTEMS FOR. SINGLE FAMILY RESIDENCES and will abide by the conditions set forth therein and on the permit to construct. wgTFR) The location of wells,( from field observation ELEVATIONS REFERENCED TO N.A.V.D. FLOOD ZONE FROM FIRM MAP NUMBER 36103CO166H SEPTEMBER 25, 2009 ANY AL7FRA77ON OR ADD177ON TO THIS SURVEY IS A V70LA77ON OF SECTION 7209OF TIE NEW YORK STATE EDUCATION LAW. EXCEPT AS PER SEC77iW 7209—SUBDIWSION 2. ALL CER77FICA77ONS HEREON ARE VALID FOR 714/S MAP AND COPIES THEREOF ONLY IF AREA = 11,488 s .ft. to lie lines SAID MAP OR CSP/ES SEAR INE /APPRESSED SEAL OF TNE-SURVEYOR Q WHOSE SIGNATURE APPEARS HEREON. Iter shown hereon. are obtained from .others. I N.YS. LIC. NO, 49618 MORS, P. C. ) FAX (631) 765-1797 P.0. BOX 909 1230 TRA VELER STREET SOUTHOLD.. N. Y. 11971 E I W 6 D cc N RECEIVED ED ---------1 I i N a I I 0 W C I o EXISTING k E SHED I I a: m O E I OCT ®�. 20I`F l I 12" DIAM. CONCRETE °D W- N ' . I I PIER FOOTING O r I®�R® FOOTING 48" � I BELOW GRADE i ®F APPEALS I J-4 6x6 post BOLT 2x8 LEDGER TO EXISTING–[J ----------- L_�__________ BA ce�__{?_PJ 24_OC STAGGERED] �L_____ r= jLINE OF EXTERIOR WALL ABOVE Btdg Dept copyfro----- .�/..�----------- --------------------------- ZBAI 'I viewed documents m # cu Date: f� RAILING- MIN. 3H0' HIGH ABOVE DEW 1" DECKING O 24'-0" LOM .. OU-------------- TREX OR EQUAL Z DECK FOUNDATION PLAN t < r' L------------------ = a Scale 1/4" V-0" _ r--------------- .---------- I GENERAL NOTES: cc M t. _–_ –r LINE OF DECK ABOVE W - ALL CONCRETE SHALL BE 3000 PSI. _________________== t---------------------1 I" SHALL BEAR ON CLEAN, C7 �= t �---- O c+ ALL FOOTINGS cD j UNDISTURBED SOIL, HAVING A MINIMUM BEARING CD j Q GIRDER (3) 2X8'S �\ �� N g j CAPACITY OF 1,500 TSF. I L__ _______ i 0 ____ i�� ___ DROP FRAMED___-- i i-{i� ALL WOOD SHALL BE PRESSURE TREATED ACQOR � 7. cII .. CU CA CD (a 10d Common nails or wooc�scr�ws �t-/ CBA -A GRADE OR CAB -C FOR GRADE CONTACT. cB staggered 16" OCI ALL TECO HANGERS SHALL BE STAINLESS STEEL. M co I W I ALL SIMPSON PRODUCTS SHALL BE A MINIMUM OF ti Z I ZMAX (G135) COATING. — 1 _LIVING FIN. ELE_ VATION 6.6` I W 6 D cc N RECEIVED ED ---------1 I i N a I I 0 W C I o EXISTING k E SHED I I a: m O E I OCT ®�. 20I`F l I 12" DIAM. CONCRETE °D W- N ' . I I PIER FOOTING O r I®�R® FOOTING 48" � I BELOW GRADE i ®F APPEALS I J-4 6x6 post BOLT 2x8 LEDGER TO EXISTING–[J ----------- L_�__________ BA ce�__{?_PJ 24_OC STAGGERED] �L_____ r= jLINE OF EXTERIOR WALL ABOVE Btdg Dept copyfro----- .�/..�----------- --------------------------- ZBAI 'I viewed documents m # cu Date: f� RAILING- MIN. 3H0' HIGH ABOVE DEW LINE OF EXISTING �-A\,$ECjT101N THRU REAR DECK B.O. FOOTING 48" BELOW GRADE >- L)z 0 (0 � J OO W =O U) W W U m Z Q W= 0 Q CO) = W LU W z 0 z 0 O 0 to � c'7 M 1 09.30.2014 1 A-01 1" DECKING TREX OR EQUAL SIMPSON H 2.5a . HURRICANE CLIPS ROOM _LIVING FIN. ELE_ VATION 6.6` DECK ELEVATION _DECK _ _ _ FIN. ELEVATION 6.4' ±2'-3" ABOVE GRADE JOIST 12" O.C. hurricane —� SEE PLAN FOR DIRECTION cli s FASCIA BOARD 2x8 GIRDER TECO JOIST HANGER OR See Plan �— VINYL LATTICE ENCLOSURE EQUAL - SECURE WITHGALV. TO Concrete NAILS Mi 4" ab Gd GRADE 6x6 post secure to pier 2 x 8 LEDGER BOARD BOLTED w/Simpson Strong Tie TO BLDG. post cap CONTINUOUS FLASHING POURED CONCRETE AT PERIMETER PIER FOOTING LINE OF EXISTING �-A\,$ECjT101N THRU REAR DECK B.O. FOOTING 48" BELOW GRADE >- L)z 0 (0 � J OO W =O U) W W U m Z Q W= 0 Q CO) = W LU W z 0 z 0 O 0 to � c'7 M 1 09.30.2014 1 A-01 4.0 CONTOUR APPROXMN AT!` --------------��� oI fV EXISTING SHED EMBEDANCHORSPER MANUFACTURER RECOMMENDATIONS EXISTING FRAMING TO REMAIN DN EX DOOR DECK PLAN Scale 1/4" = V-0" 24'-0" DN I 4R'S @6.45" Max R height: 8.25 j (R311.5.3) CENTER STAIRS ON WINDOW NEW DECK FIN ELEVATION 6.4' 1" thick DECKING MATERIAL TREX OR SIMILAR EXISTING LIVING ROOM F.F. ELEV 6.6' FIN ELEV. 4.25' approximate HANDRAILS SHALL BE IN ACCORDANCE WITH R311.5.6. TO RESIST CORROSION AND DECAY, THIS AREA SHOULD BE CAULKED DECK JOIST )4' DIAMETER APPROVED EXPANSION, EPDXY, OR ADHESIVE ANCHORS WITH WASHERS JOIST HANGER Dc LEDGER BOARD; MUST BE GREATER THAN OR EQUAL TO THE SIZE OF THE JOIST R ECK FOUNDATION WALL DETAIL �, hot to scale GUARD RAILS SHALL BE IN ACCORDANCE WITH R312, MIN V-0" HIGH INTERMEDIATE RAILS SHALL NOT ALLOW PASSAGE OF SPHERE 4" OR MORE IN DIAMETER (R312.2) EX CONCRETE STEPS TO REMAIN - NO CHANGE EX BATH . 1 I EX MASTER BEDROOM ego Bldg Dept copy from ZBA Final reviewed documents ZBA Fil / 1,461 o � . Date: O ch U 'n d �— a' Z QU rn CV O` = Co ar. � C) 5 lCd 2 rn CvaD M c_ Cu Co co ti V z Lu � ID O 2) _ . Lu :D WO Lu J 0 m Z Q Lu = oQ Co Lu W V C:). M M _- 09.30.2014 4 020-Oti.1 Tag spy® A-02 Ir - 24' -0" 8'-0" 8'-0" 8'-0" ------------------------- L ------------------------- ------------------------L------------------------ I I I I -C �r LINE OF DECK ABOVE -------------------- ------------ j Q GIRDER (3) 2X8'S j DROPFRAMED_____ � t} - --------------tom fl -------------r---- - 10d Common nails or woodT0xdws �`.� staggered 16" OC 1 w I I Z I I a I z I? 1 W o I I ---------� I II I I I W N I EXISTING I i F E I I SHED I I o m 0 E I I 12" DIAM. CONCRETE co PIER FOOTING O � m I I I B.O. FOOTING 48" I BELOW GRADE I I 6x6 post BOLT 2X8 LEDGER TO EXISTING I ---------- L— �� L-----------------� 8, (_PJ 24'_OC STAGGERED / L------------------9 ------------- --�� C,i �..� . LIVING ROOM _ FIW. ELEVATION 6.6` _ _DECK FIW. ELEVATION 6.4' LINE OF EXISTING 1" DECKING TREX OR EQUA — SIMPSON H 2.5a HURRICANE CLIPS JOIST 12" O.C. SEE PLAN FOR DIRECTION TECO JOIST HANGER OR EQUAL - SECURE WITH GALV. NAILS 2 x 8 LEDGER BOARD BOLTED TO BLDG. CONTINUOUS FLASHING AT PERIMETER 4" ab Gd RAILING;- MIN. HIGH ABOVE i GIRDER See Plan C9 x w_ -to m 0 N DECK FOUNDATION PLAN Scale 1/4" = V-0" GENERAL NOTES: ALL CONCRETE SHALL BE 3000 PSI. ALL FOOTINGS SHALL BEAR ON CLEAN, UNDISTURBED SOIL, HAVING A MINIMUM BEARING CAPACITY OF 1,500 TSF. ALL WOOD SHALL BE PRESSURE TREATED ACQ OR CBA -A GRADE OR CAB -C FOR GRADE CONTACT. ALL TECO HANGERS SHALL BE STAINLESS STEEL. ALL SIMPSON PRODUCTS SHALL BE A MINIMUM OF ZMAX (G135) COATING. APPROVED AS NOTED DATE- B.P. # I FEE-�, (f ��BY NOTIFY BUILDING DEPARTMENT AT 765-1802 8 AM TO 4 PM FOR THE FOLLOWING INSPECTIONS: 1. FOUNDATION - TWO REQUIRED LINE OF EXTERIOR WALL ABOVE FOR POURED CONCRETE ------------- 2 ROUGH - FRAMING, PLUMBING, ----------- STRAPPING, ELECTRICAL & CAULKING 3. INSULATION 4. FINAL - CONSTRUCTION & ELECTRICAL MUST BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE - REQUIREMENTS OF THE CODES OF NEVA ICU- P N 6� ' YORK STATE. NOT RESPONSIBLE FOR _ DESIGN OR CONSTRUCTION ERRORS. J'Z"E e' � i �:' I L S U u'' e' E-Z'FiRk1 F ICaAT DECK ELEVATION _ T2'-3"ABOVE GRADE FASCIA BOARD 2x8 — VINYL LATTICE ENCLOSURE 6x6 post secure to pier w/Simpson Strong Tie post cap POURED CONCRETE PIER FOOTING ,p ECTION THRU REAR DECK B.O. FOOTING ^ scale 1/2" = 1'-0" 48" BELOW GRADE N. U L i� 0 M LO 19 i U r - C � a� c`v CD r6 U") 2 CD c d Co r` r 0LU Z 0 � J OO W W O . 0 W J C) m m< W = C'^3 Q CO 2 LLILU I.L. Z C3 Z O� O M M 1 09.30.2014 1 A-01 24'-0" U CD Lo --------------------------------r1- FIN ELEV. 4.25'¢ :t::! rn a proximate o cqc HANDRAILS C N0-) SHALL BE IN ACCORDANCE = U co N WITH R311.5.6. 111 4.0 CONTOUR ���� APPROXIMAT� Li i Li 2 C/) DN 4 R'S @ 6.45" GUARD RAILS Co -0 c Max R height: 8.25 SHALL BE IN ACCORDANCE co j2 J ., 11.5.3) WITH R312, MIN 3'-0" HIGH m Co _____________- CENTER �TAIRS INTERMEDIATE RAILS SHALL ON WINDOW NOT ALLOW PASSAGE OF SPHERE 4" OR MORE IN DIAMETER (R312.2) 0 N NEW DECK FIN ELEVATION 6.4' 1" thick DECKING MATERIAL TREX OR SIMILAR U Z EXISTING SHED uj _ C3 0 J EX CONCRETE STEPS TO - NO CHANGE 0 = DN � — 2„ W - O Ex LREM,IN DOOR EXISTING LIVING ROOM EX BATHTER. BEDROOM LJ.I F.F. ELEV 6.6' 0 W J V m Z DECK PLAN o Q Scale 1/4 - 1-0 W W IX Z p Z TO RESIST CORROSION AND DECAY, THIS AREA SHOULD BE CAULKED O _ Co / M EMBED ANCHORS PER Co MANUFACTURER /f RECOMMENDATIONS DECK JOIST z Co {' Y x _ EXISTING FRAMING TO REMAIN }2" DIAMETER APPROVED EXPANSION, EPDXY, OR ADHESIVE ANCHORS WITH WASHERS OL05�� y, < i . mot . � • JOIST HANGER f�:! S i'�� ..' �. 09.30.2014 2x LEDGER BOARD; MUST BE GREATER THAN OR EQUAL TO THE SIZE OF THE JOIST A-02 r'\pECK FOUNDATION WALL DETAIL of to scale