Loading...
HomeMy WebLinkAbout39450-z � s Standby Generator - 8 kW - 10 kW - 14 kW �S�sOr2s Design and specirmtions subject to change wiUrout notice.Dimensions shown are approbmate.Contact your Generac dealer for certified drawings.DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES. 637. 1218 [25.1] [475] O 7315 [28.81 0I Oil L O O 642 76.2 t3.01� 1226 [25.3j PEA GRAVEL MINIMUM [48.3] LEFT SIDE VIEW FRONT VIEW GENE RAC' Generac Power Systems,Inc. •S45 W29290 HWY.59, Waukesha,WI 53189 • generac.com ©2009 Generac Power Systems,Inc.All rights reserved. A8 specifications are subject to change without notice. Bulletin 0181540SBY--A Pdnted in U.S.A.08/27/09 Y 7 FEATURES Standby Generator- 8 kW - 10 kW - 14 kW -Generac(OHVI)Design Maximizes engine"breathing"for increased fuel efficiency. Plateau honed cylinder walls and plasma moly rings help engine run cooler,reducing oil consumption. Because heat is the primary cause of engine wear,the OHVI has a significantly longer fife than competitive engines. -"Spiny-lok"cast iron cylinder walls Rigid construction and added durability provide long engine life. -Electronic ignition/spark advance These features combine to assure smooth,quick starting every time. -Full pressure lubrication system Superior lubrication to all vital bearings means better performance,less maintenance and significantly longer engine life.Now featuring a 2 year/200 hour oil change interval. *Low oil pressure shutdown system Superior shutdown protection prevents catastrophic engine damage due to low oil. -High temperature shutdown Prevents damage due to overheating. -Revolving field Allows for smaller,light weight unit that operates 25%more efficiently than a revolving armature generator. Skewed rotor(8&10 kW) Produces a smooth output waveform for compatibility with electronic equipment. Skewed stator(14 kW) -Displaced phase excitation Maximizes motor starting capability. -Automatic voltage regulation Regulates the output voltage to 2%prevents damaging voltage spikes. -UL 2200 Listed For your safety Sold separately -Manual/Auto/Off switch Selects the operating mode. -Utility voltage sensing Constantly monitors utility voltage,setpoints 65%dropout,75%pick-up,of standard voltage. -Utility interrupt delay Prevents nuisance start-ups of the engine,setpoint approximately 10 seconds. -Engine warm-up Ensures engine is ready to assume the load,setpoint approximately 10 seconds. -Engine cool-down Allows engine to cool prior to shutdown,setpoint approximately i minute. -Seven day exerciser Operates engine to prevent oil seal drying and damage between power outages. -Timed Trickle Battery charger Maintains battery charge level to insure starting. -Main Line Circuit Breaker Protects generator from overload. -Electronic governor(10&14 kW) Maintains constant 60 Hz frequency. -Weather protective enclosure Ensures protection against mother nature.Hinged key locking roof panel for security. Lift-out front for easy access to all routine maintenance items.Electrostatically applied textured epoxy paint for added durability. -Enclosed critical grade muffler Quiet,critical grade muffler is mounted inside the unit to prevent injuries. -Small,compact,attractive Makes for an easy,eye appealing installation. -1'Flexible Fuel Line Connector Easy Installation -Composite Mounting Pad 1 • SPECIFICATIONS GENERAC' Rated Maximum Continuous Power Capacity(LP) 8,000 Watts' 10,000 Watts' 14,000 Watts' Rated Maximum Continuous Power Capacity(NG) 7,000 Watts' 9,000 Watts' 13,000 Watts' Rated Voltage 120/240 1201240 120/240 Rated Maximum Continuous Load Current 240 Volts 33.3 LP/29.2 NO 41.6 LP/37.5 NO 58.3 LP/54.2 NO Total Harmonic Distortion Less than 5% Less than 5% Less than 5% Main Line Circuit Breaker 35 Amp 45 Amp 60 Amp Phase 1 1 1 Number of Rotor Poles 2 2 2 Rated AC Frequency 60Hz 60Hz 60Hz Power Factor 1 1 1 Battery Requirement(not included) Group 26R Group 26R Group 26R 12 Volts and 12 Volts and 12 Volts and 350 Cold-cranking 525 Cold-cranking 525 Cold-cranking Amperes Minimum Amperes Minimum Amperes Minimum Unit Weight 340 Pounds 387 Pounds 439 Pounds Dimensions(L"x W"x H") 48 x 25 x 29 48 x 25 x 29 48 x 25 x 29 Sound output in dB(A)at 23 ft. with generator operating at normal load 62 63 66 Type of Engine GENERAC OHVI GENERAC OHVI V-TWIN GENERAC OHVI V-TWIN Number of Cylinders 1 2 2 Rated Horsepower 14.8 @ 3,600 rpm 18 @ 3,600 rpm 32 @ 3,600 rpm Displacement 410cc 530cc 992cc Cylinder Block Aluminum w/Cast Aluminum w/Cast Aluminum w/Cast Iron Sleeve Iron Sleeve Iron Sleeve Valve Arrangement Overhead Valve Overhead Valve Overhead Valve Ignition System Solid-state w/Magneto Solid-state w/Magneto Solid-state w/Magneto Governor System Mechanical Electronic Electronic Compression Ratio 9.4:1 9.5:1 9.5:1 Starter 12 Vdc 12 Vdc 12 Vdc Oil Capacity Including Filter Approx.1.5 Ots. Approx.1.7 Qts. Approx.1.9 Ots. Operating RPM 3,600 3,600 3,600 Fuel Consumption Natural Gas cu.fL/hr. 1/2 Load 77 102 156 Full Load 139 156 220 Liquid Propane ft3/hr(galRtr) 112 Load 34(0.94) 46(1.25) 58(1.56) Full Load 62(l.68) 70(l.93) 84(2.30) Required fuel pressure to generator fuel inlet at all load ranges-5 to 7 inches of water column for natural gas,10 to 12 inches of water column for LP gas 2-Line Plain Text LCD Display(10&14 kW) Simple user interface for ease of operation Mode Switch -Auto Automatic Start on Utility failure.7 day exerciser .Off Stops unit Power is removed.Control and charger still operate. -Manual/Test(start) Start with starter control,unit stays on.If utility fails,transfer to load takes place. Engine Start Sequence Cyclic cranking:16 sec.on,7 rest(90 sec.maximum duration) Engine Warm-up 10 seconds Engine Cool-Down 1 minute Starter Lock-out Starter cannot re-engage until 5 sec.after engine has stopped. 2.5 Amp Timed Trickle Battery Charger Standard Automatic Voltage Regulator w/Overvoltage Protection Standard Automatic Low Oil Pressure Shutdown Standard Overspeed Shutdown Standard,72Hz High Temperature Shutdown Standard Overcrank Protection Standard Safety Fuse Standard Rating definitions-Standby:Applicable for supplying emergency power for the duration of the utility power outage.No overload capability is available for this rating.(All ratings in accordance with BS5514,IS03046 and DIN6271).'Maximum wattage and current are subject to and limited by such factors as fuel Btu content,ambient temperature,altitude,engine power and condition,etc. Maximum power decreases about 3.5 percent for each 1,000 feet above sea level;and also will decrease about 1 percent for each 12°C(10'F)above 15.5°C(60T). STANDBY GENERATORS Air-Cooled Gas Engine Generator Sets INCLUDES: Continuous Standby Power Rating • True Power® Electrical Technology • Two Line LCD Di ital Controller (10 kW & 14 kV1� • Electronic Governor (10kW & 14kW) • External Main Circuit Breaker i & System Status LED . (10kW & 14kW) • Flexible Fuel Line Connector • Composite Mounting Pad • Natural Gas or LP Gas Operation GENERAC • UL 2200 Listed • = GOOD• '•. C&S HOUSEKEEPING LISTED FEATURES are key components of GENERAC'S success in"IMPROVING POWER BY DESIGN." This state-of-the-art power maximizing regulation system is standard on But it doesn't stop there. Total commitment to component testing, all Generac models. It provides optimized FAST RESPONSE to changing reliability testing,environmental testing,destruction and life testing, load conditions and MAXIMUM MOTOR STARTING CAPABILITY by plus testing to applicable CSA,NEMA,EGSA,and other standards, electronically torque-matching the surge loads to the engine. allows you to choose GENERAC POWER SYSTEMS with the confidence that these systems will provide superior performance. from Generac's dealer network Superior harmonics provides parts and service know-how for the entire unit,from the engine and sine wave form produce less than 50%Total Harmonic Distortion for to the smallest electronic component. utility quality power.This allows confident operation of sensitive electronic equipment and micro-chip based appliances,such as variable speed HVAC. Long life and reliability are synonymous with GENERAC POWER SYSTEMS. One reason for this PROTOTYPE TESTED NEMA MG1-22 EVALUATION confidence is that the GENERAC product line includes its own transfer SYSTEM TORSIONAL TESTED MOTOR STARTING ABILITY systems and controls for total system compatibility. GENERAC ®