Loading...
HomeMy WebLinkAbout38640-Z Town of Southold Annex 10/30/2014 P.O.Box 1179 ' 54375 Main Road �F Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 37243 Date: 10/30/2014 THIS CERTIFIES that the building RESIDENTIAL ALTERATION Location of Property: 150 Shore Ln,Peconic, SCTM#: 473889 Sec/Block/Lot: 86.-14.15 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this officed dated 1/13/2014 pursuant to which Building Permit No. 38640 dated 1/27/2014 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: FINISHED BASEMENT WITH A BATHROOM IN A ONE-FAMILY DWELLING AS APPLIED FOR The certificate is issued to Tanzi,Vito&Tanzi,Lena Trieu (OWNER) of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 38640 09-02-2014 PLUMBERS CERTIFICATION DATED 10-27-2014 J. ee's Plumbing&Heating A ed ignat re TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 38640 Date: 1/27/2014 Permission is hereby granted to: Tanzi, Vito &Tanzi, Lena Trieu 70 Washington St Brooklyn, NY 11201 To: construct alterations to an existing basement as applied for At premises located at: 150 Shore Ln, Peconic SCTM # 473889 Sec/Block/Lot# 86.-1-4.15 Pursuant to application dated 1/13/2014 and approved by the Building Inspector. To expire on 7/29/2015. Fees: SINGLE FAMILY DWELLING -ADDITION OR ALTERATION $790.00 CO -ALTERATION TO DWELLING $50.00 Total: $840.00 Building Inspector } Form No.6 TOWN OF SOUTHOLD OCT 9 ?(l'4 BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY-__._. This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings,property lines,streets,and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal (S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1%lead. 5. Commercial building, industrial building,multiple residences and similar buildings and installations,a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings(prior to April 9, 1957)non-conforming uses,or buildings and"pre-existing"land uses: 1. Accurate survey of property showing all property lines, streets,building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees I. Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00,Alterations to dwelling$50.00, Swimming pool$50.00,Accessory building$50.00,Additions to accessory building$50.00,Businesses$50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy-$.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy-Residential $15.00, Commercial$15.00 Date. to IZI New Construction: Old or Pre-existing Building: (check one) Location of Property: (({IIIG� House No. / Street Hamlet Owner or Owners of Property: V (-T 9- -tlm %-I Suffolk County Tax Map No 1000, Section Block Lot % �s Subdivision Filed Map. Lot: Permit No. �j���Q Date of Permit. / Z / Applicant: 6C Health Dept.Approval: Underwriters Approval: yj�S Planning Board Approval: Z�' Request for: Temporary Certificate Final Certificate:. (check one) Fee Submitted: $ '50 / '90L,� icant ignat e *pF SOUryolo Town Hall Annex Telephone(631)765-1802 54375 Main Road C/2Fax(631)765-9502 P.O.Box 1179 roger.riche rt(CD'_town.Southold.nY.us Southold,NY 11971-0959 CpUNTY,� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION Issued To: Tanzi Address: 150 Shore Ln City: Peconic St: NY Zip: 11958 Building Permit#: 38640 Section: 86 Block: 1 Lot: 4.15 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: Glens Electric License No: 4770-me SITE DETAILS Office Use Only Residential X Indoor X Basement X Service Only Commerical Outdoor 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt 20 Ceiling Fixtures 1 HID Fixtures Service 3 ph Hot Water GFCI Recpt 4 Wall Fixtures Smoke Detectors 1 Main Panel A/C Condenser 1 Single Recpt Recessed Fixtures 41 CO Detectors Sub Panel 60a A/C Blower 1 Range Recpt Fluorescent Fixture Pumps Transformer Appliances Dryer Recpt Emergency Fixture Time Clocks Disconnect Switches 14 Twist Lock Exit Fixtures f� TVSS Other Equipment: 1-combination smoke/co detector, 1-exhaust fan, 4-ARC fault circuit breakers Notes: Inspector Signature: Date: Sept 2 2014 81-Cert Electrical Compliance Form.xls OLf soUr,�o Town Hall Amex Melephw(63.0.765-1$02 54375 Main Road Pax(631)76!�-9502 P.O.Box 1179 Southold,New York 11971-4959 `"P' • BUILDI Q DEPARThUM TOWN OF SOUTHOLD - CERTIFICATION-Date: oda Building Permit No. Owner. V170 LF�J24 TdJul (Please print) Plumber. Z 'S P>G fi b (Please print) I certify that the solder used in the water supply system contains less.than 2/10 of 10/6 lead. ILY -(Plumbefs Sigt>ature) Sworn to before me-this 1-7.01 day of Dc+vber , 201 -- - OCT 9 2014.- Notaryl Publi� OiTvL.VCounty i y UNDA&SCHOLL Notary Public.Stria of Newyork No,30.4868268 t2uali WIn Suffolk County 2C)I Comnl+ssion 41res May 6,$D-Z. FSO �0 Ut X03► yob TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECPON [ ] FOU ATION 1ST [ ROUGH PLBG. [ ] UNDATION 2ND [ ] INSULATION [ FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECT ICAL (FINAL) REMARKS: DATE /" INSPECTOR TOWN OF SOUTNOLD BUILDING DEPT. 765.1802 INSPECTION [ ] FOUNDATION 1ST [ ] GH PLBG. [ ] FOUNDATION 2ND INSULATION [ ] FRAMING/STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) REMARKS: �tIU�.P.A- DATE INSPECTOR i TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION IST [ ] ROUGH MBING [ ] FOUNDATION 2ND [ ] I LATION [ ] FRAMING /STRAPPING [ FINAL [ ] FIREPLACE A CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] CAULKING REMARKS: i DATE INSPECTOR pF SOpl�o� ` v 'co� TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1 ST [ ] ROUGH PLUMBING [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING / STRAPPING [ ] FINAL [ ] FIREPLACE A CHIMNEY [ ] FIRE SAFETY INSPECTION FIRE RESISTANTCONSTRUCTION FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) 9"LECTRICAL (FINAL) [ ] CODE VIOLATION [ ] CAULKING REMARKS: DATE l INSPECTOR FIELDN SPORT DATE COMMMS FOUNDATION(1ST) .� Y VJ FOUNDATION(2ND) F CA ROUGH FR MINQ& H PLUMBING p7 INSULATION PER N.Y. _ H STATE ENERGY CODE FINAL ADDITIONAL C6MMENTS ^�` cc, r O m r-- yV TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD,NY 11971 4 sets of Building Plans TEL: (631) 765-1802 Planning Board approval FAX: (631) 765-9502 Survey SoutholdTown.NorthFork.net PERMIT NO. ,3 V&12 Check Septic Form N.Y.S.D.E.C. Trustees Flood Permit Examined 20 I Storm-Water Assessment Form Approved ,20 JAN 13 2414 I UI Mail to: West Creek Builders L� Disapproved a/c PO Box 256, New Suffolk, NY 11956 B1_DG. SEPT. Phone:631-334-9205 Expiration 20/ 0',"!11 U0 Attn: Gary Steinfeld Building Inspector APPLICATION FOR BUILDING PERMIT Date January 10 920 14 INSTRUCTIONS a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans,accurate plot plan to scale.Fee according to schedule. b.Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas,and waterways. c.The work covered by this application may not be commenced before issuance of Building Permit. d.Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f.Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize,in writing,the extension of the permit for an addition six months.Thereafter,a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk County,New York,and other applicable Laws,Ordinances or Regulations,for the construction of buildings,additions,or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws,ordinances,building code,housing code,and regulations,and to admit authorized inspectors on premises and in building for necessary inspections. West Creek Builders. LLC (Signature of applicant or name,if a corporation) PO Box 256, New Suffolk, NY 11956 (Mailing address of applicant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician,plumber or builder General Contractor Name of owner of premises Vito & Lena Trieu Tanzi (As on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer Gary Steinfeld. Partner (Name and title of corporate officer) Builders License No. 41503-H Plumbers License No. Electricians License No. Other Trade's License No. 1. Location of land on which proposed work will be done: 150 Shore Lane, Peconic House Number Street Hamlet County Tax Map No. 1000 Section 86 Block 01 Lot 4.15 Subdivision Filed Map No. Lot 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy Single Family Residence b. Intended use and occupancy Single Family Residence 3. Nature of work(check which applicable): New Building Addition Alteration X Repair Removal Demolition Other Work (Description) 4. Estimated Cost $75,000 Fee (To be paid on filing this application) 5. If dwelling,number of dwelling units 1 Number of dwelling units on each floor If garage, number of cars 2 ``` 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of existing structures, if any: Front 70' Rear 70' Depth 60' Height 24' Number of Stories 2 Dimensions of same structure with alterations or additions: Front 70' Rear 70' Depth 60' Height 24' Number of Stories 2 8. Dimensions of entire new construction: Front Rear Depth Height Number of Stories 9. Size of lot: Front 116 Rear 185 Depth -190 10. Date of Purchase 05/11/12 Name of Former Owner Steven & Katherine Tylee 11. Zone or use district in which premises are situated R-40 12. Does proposed construction violate any zoning law, ordinance or regulation?YES NO-X 13. Will lot be re-graded?YES NO X Will excess fill be removed from premises?YES NOS_ Vito & Lena Trieu 150 Shore Lane 14. Names of Owner of premises Tanzi Address Peconic, NY Phone No. 631-236-2322 Name of Architect Address Phone No Name of Contractor West Creek Builders Address PO Box 256 Phone No. 631-334-9205 New Suffolk, NY 11956 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO X * IF YES, SOUTHOLD TOWN TRUSTEES &D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO X * IF YES,D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey, to scale,with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. 18. Are there any covenants and restrictions with respect to this property? * YES NO-X * IF YES, PROVIDE A COPY. STATE OF NEW YORK) SS: COUNTY OF ) Gary Steinfeld being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)He is the Contractor (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief;and that the work will be performed in the manner set forth in the application filed therewith. Sworn to before me thi day of 20_±j tLo_4y Public BONNIEJ.DOROSKI ignature of Applio&t Notary Public,State Of New York No. 01D06095328,Suffolk C my Term Expires July 7,20 FFO( . SCOTT A. RUSSELLo �Gy� JAMES A. RICHTER, R.A. SUPERVISOR MICHAEL M. COLLINS, P.E. N TOWN HALL - 53095 MAIN ROAD �{ yr /_ TOWN OF SOUTHOLD,NEW YORK 11971 Tel. (631)-765-1560 C'y ' �� ;y Fax. (631)-765-9015 MICHAEL.COLL1NSn.TOWN.SOUTHOLD.NY.US 1 �a�M� r JAMIE.RICHTERkTOWN.SOUTHOLD.NY.US OFFICE OF THE ENGINEER TOWN OF SOUTHOLD STORMWATER MANAGEMENT CONTROL PLAN REVIEW COVER SHEET (To be completed by the applicant) TO: Engineering Department PLEASE ATTACH. FROM: Building Department ``X Copy of the completed Application for Building Permit DATE: January 10. 2014 i Stormwater Management Control Plan APPLICANT: West Creek Builders n/a C)( Completed Stormwater Management S.C.T.M#: 1000-86-01-4.15 Control Plan Review Checklist PROPERTY ADDRESS: 150 Shore Lane, Peconic, NY BRIEF PROJECT DESCRIPTION: Interior Basement Remodel with New Basement Entrance xree a N ***FORNGI EER/ G ARTMENT USE ONLY *** Reviewe4?f4 Date: by& Ap FlAdditional Information Required: REVISED 9/17/2013 i q��pF SO(/T�ol � o Town Han Annex J Telephone(631)755-1802 54375 Main Road 66��99 UU22 - P.O.Box 1179 G Q roger.richertfa Ro`wn sZ7W'01tl ny us Southold,NY 11971-0959 BUIMING DEPARTMENT TOWN OF SOUTHOLD APPLICATION FOR ELECTRICAL INSPECTION REQUESTED BY: Date: l Company Name: GL rS Name: i. License No.: Address: !3 Phone No.: JOBSITE (NFORMATION: (*Indicates required information) *Name: *Address: *Cross Street: - -- *Phone No.: F2 vs_ Permit No.: 3 g 6 Yo Tax-Map District: 1000 Section: R G. Block: Lot:_, *BRIEF DESCRIPTION OF WORK(Please Print Clearly) _ . V (Please Circle All That Apply) *Is job ready for inspection: YES NO. Rough In Final *Do-you need a Temp Certificate: YES! NO Temp Informational a *Service Size: 1 Phase 3Phase 100 150 200 300 350 400 Other *New Service: Re-connect Underground Number of Meters Change of Service Overhead Additional Information: PAYMENT DUE WITH APPLICATION .82=Request for Inspection Form C I. . s *pF SOUryolo Town Hall Annex Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 1179 C/2 • Southold,NY 11971-0959 'Q reonTY,� August 29, 2014 BUILDING DEPARTMENT TOWN OF SOUTHOLD West Creek Builders PO Box 256 New Suffolk, NY 11956 Re: Tanzi, 150 Shore Lane, Peconic TO WHOM IT MAY CONCERN: The Following Items(if Checked)Are Needed To Complete Your Certificate of Occupancy: ✓ Application for Certificate of Occupancy. (Enclosed) Wlctrical Underwriters Certificate. A fee of$50.00. ` Final Health Department Approval. ✓ Plumbers Solder Certificate. (All permits involving plumbing after 4/1/84) Trustees Certificate of Compliance. (Town Trustees#765-1892) Final Planning Board Approval. (Punning#765-1938) Final Fire Inspection from Fire Marshall. Final Landmark Preservation approval. Final inspection by Building Dept. Final Storm Water Runoff Approval from Town Engineer BUILDING PERMIT — 38640 — Basement Alterations • 4 ` PIAT PLAN LOT 15 M" OF RICHUOND SHORES AT- PECONIC fxf tic SM roLm OWDOM 20. IM �J SITUATED Ar PECONIC "IVTOWN OF SOUTHOLD SUFFOLK COUNTY, NEW YORK S.C. TAX No. 1000-86-01-4.15 SCALE 1'=40' J6 r+ y a OECEMOM 21. 1999 AREA = 27,396.03 q. tt. 0.622JPM Zell KA'rlM flRa O. �[AIOCAII I= sir1�MICT C�IMf .10 ASA- VIP 40 J680Ph A. • C� W IK L� SUMeytw i MW - QwrrA� i 1 � PPIP, 62'-10 13/16" DATE � P L U.!1BI�'t�! n �� �� ALL PLU" .;IiV�4Y'r;v;E 2'-915/16" 2'-915/16" ,1� 20'-6 1/2 6-4 27 -0 1/4FES __ d•_....4, .. _. / �— &WATER LINES NEED NOTIFY DUIiLOr, TESTING BEFORE C0V .;i!I`d,;a 765-1,802 8 FOLLOWING pc Tl� 1. FOUNDA.T 1';`N -o FOR POURED ROUGH-FRAM NG,P[11 STRAPPING, ELECT� IGAW h PLUMBER CER TIFICATf?��;'� 3. INSULATION FINAL coNsrR!�cT!or,! �:: DL EC: ON LLEA D C.CiVTENT SEFjj-,;� MUST BE COMPLETE FOR C 0. CERT%i=/GATE OF ALL CONSTRUCTION SHALL I'�,1FET-1-I"_ OCCUPI,LSC' SOLDER USED IN EOU;REMENTS OF THE COLDES OF i W ' ORI<STATE. NOT RESPd�'i�LE FGR SUPPLYSYST'EMCfii',',`, ,) DESIGN OR CONSTRUCTION ERRORS EXCEED 2110 OF 15/ 1.l � 00 10'-7 7/8" \ ♦T�/� \1! W E.-WEST CREK Al 'DESIGN BUILD REMODEL . . . : ..........::.:.:..: 58'-2 5/8" DESIGN: T LO West Creek Builders, LLC PO Box 256 EXISTING BASEMENT 1800 so FT _ New Suffolk, NY 11956 BOILER oo _ T 631 .734.8416 C� CD \ (0 LVL GIRDER&COLUMNS LO C'7 �_ CD rT O C\I � ENGINEER: � T T 00 HOT WATER co James J. Deerkoski, P.E. TANK 0 260 Deer Drive co ELECTRICAL SERVICE Mattituck, NY 11952 PANEL CV \ UP LVL GIRDER COLUMNS O O O 01 REVISIONS / ISSUE: 77 777 Permit Set 01 .08.14 Cq CD 32'-8 1/8"LO iX til U-) 1 1, ..: PROJLO . T Residence anzi 'sem Basement Remodel WATER SERVICE 150 Shore Lane Peconic, NY 11958 2'-10 7/8" LEE 20'-6 1/2" 4'-4 5/8" 13'-2 1/4" 13'-6 3/8" 5 'F NEW P� . D-- 0,p� DRAWING: 62'-10 13/16 * Uj EXISTING FLOOR PLAN Uj Ul EXISTING BASEMENT FLOOR PLAN °A�0 4 -2� ��� LEC _SSI, SCALE : 1 4" = V-011 PROJECT NORTH � INTERIOR PERIMETER WALLS: NEW BASEMENT ENTRANCE: 1) 1" RIGID EPS FOAM ADHERED TO EXISTING CONCRETE WALLS 1) 8" THICK POURED CONCRETE FOUNDATION ON 16"X8" CONCRETE FOOTING. 2) 2X4 FRAMED WALLS AGAINST EPS FOAM 2) 4" CONCRETE LANDING AT TOP AND BOTTOM OF STAIRS 3) R13 BATT INSULATION IN WALL CAVITY 3) 4" DRAIN WITH GRATE TO 24" DRYWELL AT BOTTOM LANDING 4) 1/2" MOISTURE RESISTANT DRYWALL 4) NON-SLIP CONCRETE STAIRS TO GRADE WITH HANDRAIL 5) ALL BOTTOM PLATES TO BE PRESSURE TREATED 5) 36" HIGH GUARD RAIL ON TOP OF CONCRETE WALL 6) RIGID EPS FOAM AT ALL RIM BOARDS NEW BASEMENT ENTRANCE 16' FLOORING: 1) 3/4" RIGID EPS FOAM ABOVE EXISTING SLAB. TAPE ALL SEAMS ' — — — — — — — --- — — — — WINE CELLAR 2) 3/4" T&G PLYWOOD SUBLFLOOR SCREWED TO SLAB — — — — — 1 coo WEST CREED 3) FINISHED FLOORING REF 9' RAIN D -915/16" � UP ° BAR I I DESIGN ( BUILD REMODEL SINK •E: F• - 3069 _ V I iww I I � - - -� - - - � DESIGN: West Creek Builders, LLC 19'-4 11/16" PO Box 256 EGRESS o New Suffolk, NY 11956 WINDOW N VIDEO GAMING ROOM T 631 .734.8416 AND WELL (0 PLAY AREA N T' N _._..... T 3�'-8 7/16" ENGINEER. 9969 IN O UND LATE EXISTING COLUMNS James J. Deerkoski P.E. 1 - WALLS 4 260 Deer Drive — , N — — — — — — — — — — — 13/4'�' OSOFFITCfl Mattituck, NY 11952 FIRE RATED — — — — — — — — — Ch DRYWALL AT SHARED WALLS TV&BUILT-IN FOR COMPONENTS M UNFINISHED a\o MECHANICAL ROOM o\0 ELECTR AL SERVICE PANEL :. REVISIONS / ISSUE: 151-511— U' GRINDER PUMP P EXISTINGCOLUMN MECHANICAL Permit Set 01 .08.14 SUMP SYSTEM FOR — — — BATH& BAR SINK O O 24246BO O SOFFIT - I I 2X6 WALL - HVAC L —J 00 8'-4" • - EXERCISE AREA K ' BATH PROJECT: 2969 23'-2 5/8" Tanzi Residence o Basement Remodel LO r 150 Shore Lane LINEN CLOSET M N x . Peconic, NY 11958 a. :. ACCESS DOOR — T TO WATER SERVICE 9'-8 1/4" 0 NEIVDRAWING. PROPOSED FLOOR PLAN rn w PROPOSED BASEMENT FLOOR PLAN �� ,� oA � 7 ���C�C1 PROJECT NORTH SCALE . 1/4 = 1'-011 PLAN CONTENTS: BASEMENT REMODEL 1,475 SQ.FT. DESIGN CRITERIA PRESCRIPTIVE AS PER N.Y.S. RESIDENTIAL CONSTRUCTION CODE AND 1995 SBC HIGH WIND EDITION,WOOD FRAME CONSTRUCTION MANUAL FRAMING ELEMENTS AS PER FLOOR PLANS,CROSS SECTIONS AND GENERAL NOTES DESIGN LOAD CALCULATIONS EXT.BALCONIES 60 (LIVE LOADS PSF) DECKS 40 ATTICS W/O STORAGE 10 ATICS WITH STORAGE 20 ROOF GROUND SNOW LOAD 45 NAILING SCHEDULE ROOMS OTHER THAN SLEEPING 40 ROOMS SLEEPING 30 TABLE 3.1,INCLUDING 3.3 AND 3.9 STAIRS 40 1995 SBC HIGH WIND ADDITION WOOD FRAME CONSTRUCTION MANUAL GUARDRAILS ANY DIRECTION 200 JOINT DESCRIPTION NAIL QUANTITY NAIL SPACING NOTES EXPOSURE CATEGORY ROOF FRAMING LOAD PATH SEE CONSTRUCTION AND WIND PATH CONNECTION DETAILS AND RAFTER TO TO PLATE 8'WALL:3-8d EACH RAFTER TOE NAIL ROOF-FOUNDATION' GENERAL NOTES NAILING SCHEDULE SEE GENERAL NOTES 10' WALL: 4- 8d EACH RAFTER TOE NAIL CLIMATIC AND GEOGRAPHIC GROUND SNOW LOAD 45 LBS. CEILING JOIST TO TOP PLATE 8'WALL: 3 8d PER JOIST TOE NAIL CRITERIA WIND SPEED MPH 120 10' WALL:4- Bd PER JOIST TOE NAIL SEISMIC CATEGORY B CEILING JOIST TO PARALLEL RAFTER SEE TABLE 3.7 EACH LAP FACE NAIL WEATHERING SEVERE FROST LINE DEPTH 3 FT. CEILING JOIST LAPS OVER PARTITION SEE TABLE 3.7 EACH LAP FACE NAIL TERMITE MODERATE TO HEAVY COLLAR TIE TO RAFTER SEE TABLE 3.4 PER TIE FACE NAIL DECAY SLIGHT TO MODERATE BLOCKING TO RAFTER 2-8d EACH END TOE NAIL WINTER DESIGN TEMP. 11 ICESHIELD UNDERLAYMENT REQUIRED AT ROOF<4:12 RIM BOARD TO RAFTER 2-16d EACH END END NAIL FLOOD HAZARDS INONE WEST CREED. WALL FRAMING TOP PLATE TO TOP PLATE 2-16d PER FOOT FACE NAIL TOP PLATES ATINERSECTIONS 4-16d JOINTS- EACH SIDE FACE NAIL DESIGN I BUILD I REMODEL STUD TO STUD 2-16d 24"OC FACE NAIL HEADER TO HEADER 16d 16"OC ALONG EDGES FACE NAIL TOP OR BOTTOM PLATE TO STUD 2-16d PER 2X4 STUD END NAIL 3-16d PER 2X6 STUD END NAIL CONSTRUCTION NOTES: 4-16d PER 2X8 STUD END NAIL 1) The information within this set of construction documents is related to basic design intent BOTTOM PLATE TO FLOOR JOIST, DESIGN and framing details. They are intended as a construction aid, not a substitute for generally BAN DJOIST,END JOIST,OR BLOCKING 2-16d PER FOOT FACE NAIL accepted good building practice and compliance with current New York State building West Creek Builders,LLC codes. The General Contractor is responsible for providing standard construction details FLOOR FRAMING PO Box 256 and procedures to ensure a professionally finished, structurally sound and a weatherproof JOIST TO SILL,TOP PLATE,OR GIRDER 4-8d PER JOIST TOE NAIL Completed product. BRIDGING TO JOIST 2-8d EACH END TOE NAIL New Suffolk, NY 11956 2) The General Contractor is responsible for ensuring that all work and construction meets BLOCKING TO JOIST 2-8d EACH END TOE NAIL T 631 .734.8416 current federal, state, county and local codes, ordinances and regulations, etc. These BLOCKING TO SILL OR TOP PLATE 3-16d EACH BLOCK TOE NAIL codes are to be considered as part of the specifications for this building and should be LEDGER STRIP TO BEAM 3-16d EACH JOIST FACE NAIL JOIST ON LEDGER TO BEAM 3-8d PER JOIST TOE NAIL adhered t0 even if in variance with the plan. BAND JOIST TO JOIST 3-16d PER JOIST END NAIL 3) Dimensions shall take precedent Over scaled drawings. (DO NOT SCALE DRAWINGS). BAND JOIST TO SILL ORITOP PLATE 2-16d PER FOOT TOE NAIL ENGINEER: 4) The designer has not been engaged for construction supervision and assumes no responsibility for construction coordinating with these plans, nor responsibility for ROOF SHEATHING James J. Deerkoski, P.E. construction means, methods, techniques, sequences, or procedures, or for safety STRUCTURAL PANELS 8d 4'PERIMERTER EDGE ZONE-16"OC-6" AT PANEL 260 Deer Drive precautions and programs in connection with the work. There are no warranties for a EDGESANDAT INTERMEDIATE SUPPORTS IN THE PANEL specific use expressed Or implied in the use of these plans. 8d INTERIOR ZONE-16"OC-6"AT PANEL EDGES AND 12" Mattituck, NY 11952 J) Refer to the Window and Door schedule for exterior openings. AT INTERMEDEDIATE SUPPORTS IN THE PANEL FIELD 6) The General Contractor is to consult with the Owner for all built-in items such as FOR ROOF SHEATHING WITHIN 4'OF THE PERIMETER OF THE ROOF,INCLUDING 4'ON EACH SIDE OF THE ROOF PEAK,THE 4'PERIMETER EDGE ZONE ATTACHMENT REQUIREMENTS SHALL BE USED. bookcases, shelving, pantry, closets, trims, etc. CEILING SHEATHING GYPSUM WALLBOARD 5d COOLERS 7" EDGE/10" FIELD ELECTRICAL NOTES: REVISIONS / ISSUE: 1) All electrical work shall be performed by a licensed electrical contractor and fully meet the WALL SHEATHING requirements of the National Electrical Code, The New York State Building Code, and all STRUCTURAL PANELS 8d WEDGE ZONE- 16"OC-6"AT PANEL EDGES AND 12"AT Permit Set 01 .08.14 INTERMEDEDIATE SUPPORTS IN THE PANEL FIELD other applicable local codes and ordinances. gd INTERIOR ZONE- 16"OC-6"AT PANEL EDGES AND 12" 2) All electrical work shall be approved by a qualified Underwriter. AT INTERMEDEDIATE SUPPORTS IN THE PANEL FIELD 3) Install smoke detectors and carbon monoxide detectors throughout as per Construction FIBER BOARD PANELS 7/16" 6d 3"EDGE/6"FIELD Code, 25/32" 8d 3"EDGE/6" FIELD GYPSUM WALLBOARD 5d COOLERS 7" EDGE/10" FIELD HARDBOARD 8d 4'EDGE ZONE-16"OC-6"AT PANEL EDGES AND 12"AT INTERMEDEDIATE SUPPORTS IN THE PANEL FIELD PROJECT: HVAC NOTES: 8d INTERIOR ZONE-16"OC-6"AT PANEL EDGES AND 12" 1) Mechanical subcontractor is responsible for adhering to all applicable codes and safety AT INTERMEDEDIATE SUPPORTS IN THE PANEL FIELD Tanzi Residence requirements. 2) HVAC subcontractor is to fully coordinate all system data and requirements with the FLOOR SHEATHING Basement Remodel equipment Supplier. STRUCTURAL PANELS 1"OR LESS 8d 6"EDGE/12" FIELD 150 Shore Lane 3) HVAC subcontractor to provide final system layout drawing and submit it to the General NAILING REQUIREMENTS ARE BASED ON WALL SHEATHING NAILED 6 OC AT THE PANEL EDGE. IF WALL SHEATHING IS Contractor and Owner for final review and approval. NAILED 3"OC AT THE PANEL EDGE TO OBTAIN HIGHER SHEAR CAPACITIES,NAILING REQUIREMENTS FOR STRUCTURAL Peconic, NY 11958 MEMBERS SHALL BE DOUBLED OR ALTERNATE CONNECTORS SUCH AS SHEAR PLATES,SHALL BE USED TO MAINTAIN LOAD PATH. WHEN WALL SHEATHING IS CONTINUOUS OVER CONNECTED MEMBERS,THE TABULATED NUMBER OF NAILS SHALL BE PERMITTED TO BE REDUCED TO 1-16d NAIL PER FOOT. � ()Fw>- DRAWING: * CONSTRUCTION NOTES 07 A3 Z � ktr �S qtr. NYS ENERGY COMPLIANCE VENT VENT RESicheck Software Version 4.4.4 Compliance Certificate EXISTING HOUSE MAIN Project Title: Tanzi Residnence - Basement Remodel WEST CREEK TO SEPTIC SYSTEM Energy Code: 2010 New York Energy Conservation Location: Suffolk County, New York Construction Type: Single Family DESIGN I BUILD I REMODEL 1 1/2 Project Type: Alteration 1 1/2 Conditioned Floor Area: 0 ft2 1 1/2 1 1/2 Heating Degree Days: 5750 BAR SINK Climate Zone: 4 LAV. W. C. LAV. Permit Date: DESIGN: —c DRAIN PUMP Construction Site: Owner/Agent: Designer/Contractor: West Creek Builders, LLC SHOWER OR BATH 150 Shore Lane Peconic,NY 11958 PO Box 256 4 GRINDER PUMP SYSTEM INC L.HIGHLEVELALARM New Suffolk, 11956 Maximum UA: 146 Your UA: 136 T 631 .734.8416 RISER DIAGRAM N .T.S. Envelope Ass>emblies ENGINEER: Gross Cavity Cont. Glazing Assembly Areaor -Value or Door UA James J. Deerkoski, P.E. Perimeter U-Pactor Basement Wall 1:Solid Comcrete or Masonry 1,475 13.0 5.0 68 260 Deer Drive Wall height:8.0' Depth below grade:6.0' _ _y. Mattituck, NY 11952 Insulation depth:8.0' Window 1:Vinyl Frame:Doluble Pane 32 0.300 10 SHGC:0.00 Door 1:Solid 20 0.300 6 PLUMBING NOTES: _ Ceiling 1: Flat Ceiling or Scissor Truss 475 30.0 0.0 52 1) All water supply, drainage and venting to be installed as per N.Y.S. Residential OF NES, Construction Code. Compliance Statement. The proposed building design described here is consist w� 1 pecifications,and other calculations REVISIONS / ISSUE: 2 If wall studs plates or joists are cut out Burin installation for an plumbing related work submitted with the permit application.The proposed building has., designe o fc�fle 01 nergy Conservation Construction Code , p j g y p g , requirements in REScheck Version 4.4.4 and to comply with the h anda re ids I' to the c k Inspection Checklist. provide adequate bracing and plates to protect and secure the structure. Verify with state ���yt�o5u : • .. � � to ' Permit Set 01 .08.14 code and manufacturer's recommendation for maximum hole size and spacing permitted. � s Name-Title Signatu Dat ,off° 07250)L �O'ESSloNA PROJECT: Tanzi Residence Basement Remodel Project Title: Tanzi Residnence-Basement Remodel Report 01/09/14 150 Shore Lane Data filename: C:\User,,s\West Creek\DocumentslREScheck\TanziResidenceBasement.rck Page 1 of 1 Peconic, NY 11958 E �EOFNEh, DRAWING: � *�QJ Dr )�° CONSTRUCTION NOTES m _ o: A4