HomeMy WebLinkAbout38640-Z Town of Southold Annex 10/30/2014
P.O.Box 1179
' 54375 Main Road
�F Southold,New York 11971
CERTIFICATE OF OCCUPANCY
No: 37243 Date: 10/30/2014
THIS CERTIFIES that the building RESIDENTIAL ALTERATION
Location of Property: 150 Shore Ln,Peconic,
SCTM#: 473889 Sec/Block/Lot: 86.-14.15
Subdivision: Filed Map No. Lot No.
conforms substantially to the Application for Building Permit heretofore filed in this officed dated
1/13/2014 pursuant to which Building Permit No. 38640 dated 1/27/2014
was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for
which this certificate is issued is:
FINISHED BASEMENT WITH A BATHROOM IN A ONE-FAMILY DWELLING AS APPLIED FOR
The certificate is issued to Tanzi,Vito&Tanzi,Lena Trieu
(OWNER)
of the aforesaid building.
SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL
ELECTRICAL CERTIFICATE NO. 38640 09-02-2014
PLUMBERS CERTIFICATION DATED 10-27-2014 J. ee's Plumbing&Heating
A ed ignat re
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
TOWN CLERK'S OFFICE
SOUTHOLD, NY
BUILDING PERMIT
(THIS PERMIT MUST BE KEPT ON THE PREMISES
WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS
UNTIL FULL COMPLETION OF THE WORK AUTHORIZED)
Permit#: 38640 Date: 1/27/2014
Permission is hereby granted to:
Tanzi, Vito &Tanzi, Lena Trieu
70 Washington St
Brooklyn, NY 11201
To: construct alterations to an existing basement as applied for
At premises located at:
150 Shore Ln, Peconic
SCTM # 473889
Sec/Block/Lot# 86.-1-4.15
Pursuant to application dated 1/13/2014 and approved by the Building Inspector.
To expire on 7/29/2015.
Fees:
SINGLE FAMILY DWELLING -ADDITION OR ALTERATION $790.00
CO -ALTERATION TO DWELLING $50.00
Total: $840.00
Building Inspector
}
Form No.6
TOWN OF SOUTHOLD OCT 9 ?(l'4
BUILDING DEPARTMENT
TOWN HALL
765-1802
APPLICATION FOR CERTIFICATE OF OCCUPANCY-__._.
This application must be filled in by typewriter or ink and submitted to the Building Department with the following:
A. For new building or new use:
1. Final survey of property with accurate location of all buildings,property lines,streets,and unusual natural or
topographic features.
2. Final Approval from Health Dept. of water supply and sewerage-disposal (S-9 form).
3. Approval of electrical installation from Board of Fire Underwriters.
4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1%lead.
5. Commercial building, industrial building,multiple residences and similar buildings and installations,a certificate
of Code Compliance from architect or engineer responsible for the building.
6. Submit Planning Board Approval of completed site plan requirements.
B. For existing buildings(prior to April 9, 1957)non-conforming uses,or buildings and"pre-existing"land uses:
1. Accurate survey of property showing all property lines, streets,building and unusual natural or topographic
features.
2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is
denied,the Building Inspector shall state the reasons therefor in writing to the applicant.
C. Fees
I. Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00,Alterations to dwelling$50.00,
Swimming pool$50.00,Accessory building$50.00,Additions to accessory building$50.00,Businesses$50.00.
2. Certificate of Occupancy on Pre-existing Building- $100.00
3. Copy of Certificate of Occupancy-$.25
4. Updated Certificate of Occupancy- $50.00
5. Temporary Certificate of Occupancy-Residential $15.00, Commercial$15.00
Date. to IZI
New Construction: Old or Pre-existing Building: (check one)
Location of Property: (({IIIG�
House No. / Street Hamlet
Owner or Owners of Property: V (-T 9- -tlm %-I
Suffolk County Tax Map No 1000, Section Block Lot % �s
Subdivision Filed Map. Lot:
Permit No. �j���Q Date of Permit. / Z / Applicant: 6C
Health Dept.Approval: Underwriters Approval: yj�S
Planning Board Approval: Z�'
Request for: Temporary Certificate Final Certificate:. (check one)
Fee Submitted: $ '50 / '90L,�
icant ignat e
*pF SOUryolo
Town Hall Annex Telephone(631)765-1802
54375 Main Road C/2Fax(631)765-9502
P.O.Box 1179 roger.riche rt(CD'_town.Southold.nY.us
Southold,NY 11971-0959 CpUNTY,�
BUILDING DEPARTMENT
TOWN OF SOUTHOLD
CERTIFICATE OF ELECTRICIAL COMPLIANCE
SITE LOCATION
Issued To: Tanzi
Address: 150 Shore Ln City: Peconic St: NY Zip: 11958
Building Permit#: 38640 Section: 86 Block: 1 Lot: 4.15
WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE
Contractor: DBA: Glens Electric License No: 4770-me
SITE DETAILS
Office Use Only
Residential X Indoor X Basement X Service Only
Commerical Outdoor 1st Floor Pool
New Renovation 2nd Floor Hot Tub
Addition Survey Attic Garage
INVENTORY
Service 1 ph Heat Duplec Recpt 20 Ceiling Fixtures 1 HID Fixtures
Service 3 ph Hot Water GFCI Recpt 4 Wall Fixtures Smoke Detectors 1
Main Panel A/C Condenser 1 Single Recpt Recessed Fixtures 41 CO Detectors
Sub Panel 60a A/C Blower 1 Range Recpt Fluorescent Fixture Pumps
Transformer Appliances Dryer Recpt Emergency Fixture Time Clocks
Disconnect Switches 14 Twist Lock Exit Fixtures f� TVSS
Other Equipment: 1-combination smoke/co detector, 1-exhaust fan, 4-ARC fault circuit breakers
Notes:
Inspector Signature: Date: Sept 2 2014
81-Cert Electrical Compliance Form.xls
OLf soUr,�o
Town Hall Amex Melephw(63.0.765-1$02
54375 Main Road Pax(631)76!�-9502
P.O.Box 1179
Southold,New York 11971-4959 `"P' •
BUILDI Q DEPARThUM
TOWN OF SOUTHOLD
-
CERTIFICATION-Date: oda
Building Permit No.
Owner. V170 LF�J24 TdJul
(Please print)
Plumber. Z 'S P>G fi b
(Please print)
I certify that the solder used in the water supply system contains less.than 2/10 of 10/6
lead.
ILY -(Plumbefs Sigt>ature)
Sworn to before me-this 1-7.01
day of Dc+vber , 201 -- -
OCT 9
2014.-
Notaryl
Publi� OiTvL.VCounty
i
y
UNDA&SCHOLL
Notary Public.Stria of Newyork
No,30.4868268
t2uali WIn Suffolk County 2C)I
Comnl+ssion 41res May 6,$D-Z.
FSO
�0 Ut
X03► yob
TOWN OF SOUTHOLD BUILDING DEPT.
765-1802
INSPECPON
[ ] FOU ATION 1ST [ ROUGH PLBG.
[ ] UNDATION 2ND [ ] INSULATION
[ FRAMING /STRAPPING [ ] FINAL
[ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION
[ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION
[ ] ELECTRICAL (ROUGH) [ ] ELECT ICAL (FINAL)
REMARKS:
DATE /" INSPECTOR
TOWN OF SOUTNOLD BUILDING DEPT.
765.1802
INSPECTION
[ ] FOUNDATION 1ST [ ] GH PLBG.
[ ] FOUNDATION 2ND INSULATION
[ ] FRAMING/STRAPPING [ ] FINAL
[ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION
[ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION
[ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL)
REMARKS: �tIU�.P.A-
DATE INSPECTOR
i
TOWN OF SOUTHOLD BUILDING DEPT.
765-1802
INSPECTION
[ ] FOUNDATION IST [ ] ROUGH MBING
[ ] FOUNDATION 2ND [ ] I LATION
[ ]
FRAMING /STRAPPING [ FINAL
[ ] FIREPLACE A CHIMNEY [ ] FIRE SAFETY INSPECTION
[ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION
[ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL)
[ ] CODE VIOLATION [ ] CAULKING
REMARKS:
i
DATE INSPECTOR
pF SOpl�o�
` v 'co�
TOWN OF SOUTHOLD BUILDING DEPT.
765-1802
INSPECTION
[ ] FOUNDATION 1 ST [ ] ROUGH PLUMBING
[ ] FOUNDATION 2ND [ ] INSULATION
[ ] FRAMING / STRAPPING [ ] FINAL
[ ] FIREPLACE A CHIMNEY [ ] FIRE SAFETY INSPECTION
FIRE RESISTANTCONSTRUCTION FIRE RESISTANT PENETRATION
[ ] ELECTRICAL (ROUGH) 9"LECTRICAL (FINAL)
[ ] CODE VIOLATION [ ] CAULKING
REMARKS:
DATE l INSPECTOR
FIELDN SPORT DATE COMMMS
FOUNDATION(1ST) .�
Y VJ
FOUNDATION(2ND)
F
CA
ROUGH FR MINQ& H
PLUMBING
p7
INSULATION PER N.Y. _ H
STATE ENERGY CODE
FINAL
ADDITIONAL C6MMENTS ^�`
cc, r
O
m
r--
yV
TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST
BUILDING DEPARTMENT Do you have or need the following,before applying?
TOWN HALL Board of Health
SOUTHOLD,NY 11971 4 sets of Building Plans
TEL: (631) 765-1802 Planning Board approval
FAX: (631) 765-9502 Survey
SoutholdTown.NorthFork.net PERMIT NO. ,3 V&12 Check
Septic Form
N.Y.S.D.E.C.
Trustees
Flood Permit
Examined 20 I Storm-Water Assessment Form
Approved ,20
JAN 13 2414 I UI Mail to: West Creek Builders
L�
Disapproved a/c PO Box 256, New Suffolk, NY 11956
B1_DG. SEPT. Phone:631-334-9205
Expiration 20/ 0',"!11 U0 Attn: Gary Steinfeld
Building Inspector
APPLICATION FOR BUILDING PERMIT
Date January 10 920 14
INSTRUCTIONS
a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4
sets of plans,accurate plot plan to scale.Fee according to schedule.
b.Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or
areas,and waterways.
c.The work covered by this application may not be commenced before issuance of Building Permit.
d.Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit
shall be kept on the premises available for inspection throughout the work.
e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector
issues a Certificate of Occupancy.
f.Every building permit shall expire if the work authorized has not commenced within 12 months after the date of
issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the
property have been enacted in the interim,the Building Inspector may authorize,in writing,the extension of the permit for an
addition six months.Thereafter,a new permit shall be required.
APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the
Building Zone Ordinance of the Town of Southold,Suffolk County,New York,and other applicable Laws,Ordinances or
Regulations,for the construction of buildings,additions,or alterations or for removal or demolition as herein described. The
applicant agrees to comply with all applicable laws,ordinances,building code,housing code,and regulations,and to admit
authorized inspectors on premises and in building for necessary inspections.
West Creek Builders. LLC
(Signature of applicant or name,if a corporation)
PO Box 256, New Suffolk, NY 11956
(Mailing address of applicant)
State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician,plumber or builder
General Contractor
Name of owner of premises Vito & Lena Trieu Tanzi
(As on the tax roll or latest deed)
If applicant is a corporation, signature of duly authorized officer
Gary Steinfeld. Partner
(Name and title of corporate officer)
Builders License No. 41503-H
Plumbers License No.
Electricians License No.
Other Trade's License No.
1. Location of land on which proposed work will be done:
150 Shore Lane, Peconic
House Number Street Hamlet
County Tax Map No. 1000 Section 86 Block 01 Lot 4.15
Subdivision Filed Map No. Lot
2. State existing use and occupancy of premises and intended use and occupancy of proposed construction:
a. Existing use and occupancy Single Family Residence
b. Intended use and occupancy Single Family Residence
3. Nature of work(check which applicable): New Building Addition Alteration X
Repair Removal Demolition Other Work
(Description)
4. Estimated Cost $75,000 Fee
(To be paid on filing this application)
5. If dwelling,number of dwelling units 1 Number of dwelling units on each floor
If garage, number of cars 2 ```
6. If business, commercial or mixed occupancy, specify nature and extent of each type of use.
7. Dimensions of existing structures, if any: Front 70' Rear 70' Depth 60'
Height 24' Number of Stories 2
Dimensions of same structure with alterations or additions: Front 70' Rear 70'
Depth 60' Height 24' Number of Stories 2
8. Dimensions of entire new construction: Front Rear Depth
Height Number of Stories
9. Size of lot: Front 116 Rear 185 Depth -190
10. Date of Purchase 05/11/12 Name of Former Owner Steven & Katherine Tylee
11. Zone or use district in which premises are situated R-40
12. Does proposed construction violate any zoning law, ordinance or regulation?YES NO-X
13. Will lot be re-graded?YES NO X Will excess fill be removed from premises?YES NOS_
Vito & Lena Trieu 150 Shore Lane
14. Names of Owner of premises Tanzi Address Peconic, NY Phone No. 631-236-2322
Name of Architect Address Phone No
Name of Contractor West Creek Builders Address PO Box 256 Phone No. 631-334-9205
New Suffolk, NY 11956
15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO X
* IF YES, SOUTHOLD TOWN TRUSTEES &D.E.C. PERMITS MAY BE REQUIRED.
b. Is this property within 300 feet of a tidal wetland? * YES NO X
* IF YES,D.E.C. PERMITS MAY BE REQUIRED.
16. Provide survey, to scale,with accurate foundation plan and distances to property lines.
17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey.
18. Are there any covenants and restrictions with respect to this property? * YES NO-X
* IF YES, PROVIDE A COPY.
STATE OF NEW YORK)
SS:
COUNTY OF )
Gary Steinfeld being duly sworn,deposes and says that(s)he is the applicant
(Name of individual signing contract)above named,
(S)He is the Contractor
(Contractor,Agent,Corporate Officer,etc.)
of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;
that all statements contained in this application are true to the best of his knowledge and belief;and that the work will be
performed in the manner set forth in the application filed therewith.
Sworn to before me thi
day of 20_±j
tLo_4y Public BONNIEJ.DOROSKI ignature of Applio&t
Notary Public,State Of New York
No. 01D06095328,Suffolk C my
Term Expires July 7,20
FFO( .
SCOTT A. RUSSELLo �Gy� JAMES A. RICHTER, R.A.
SUPERVISOR MICHAEL M. COLLINS, P.E.
N
TOWN HALL - 53095 MAIN ROAD �{ yr /_ TOWN OF SOUTHOLD,NEW YORK 11971
Tel. (631)-765-1560 C'y ' �� ;y Fax. (631)-765-9015
MICHAEL.COLL1NSn.TOWN.SOUTHOLD.NY.US 1 �a�M� r JAMIE.RICHTERkTOWN.SOUTHOLD.NY.US
OFFICE OF THE ENGINEER
TOWN OF SOUTHOLD
STORMWATER MANAGEMENT CONTROL PLAN REVIEW COVER SHEET
(To be completed by the applicant)
TO: Engineering Department PLEASE ATTACH.
FROM: Building Department ``X Copy of the completed Application for
Building Permit
DATE: January 10. 2014
i Stormwater Management Control Plan
APPLICANT: West Creek Builders n/a
C)( Completed Stormwater Management
S.C.T.M#: 1000-86-01-4.15 Control Plan Review Checklist
PROPERTY ADDRESS: 150 Shore Lane, Peconic, NY
BRIEF PROJECT DESCRIPTION:
Interior Basement Remodel with New Basement Entrance
xree a
N
***FORNGI EER/ G ARTMENT USE ONLY ***
Reviewe4?f4 Date: by&
Ap
FlAdditional Information Required:
REVISED 9/17/2013
i
q��pF SO(/T�ol
� o
Town Han Annex J Telephone(631)755-1802
54375 Main Road 66��99 UU22 -
P.O.Box 1179 G Q roger.richertfa Ro`wn sZ7W'01tl ny us
Southold,NY 11971-0959
BUIMING DEPARTMENT
TOWN OF SOUTHOLD
APPLICATION FOR ELECTRICAL INSPECTION
REQUESTED BY: Date: l
Company Name: GL rS
Name: i.
License No.:
Address: !3
Phone No.:
JOBSITE (NFORMATION: (*Indicates required information)
*Name:
*Address:
*Cross Street: - --
*Phone No.: F2 vs_
Permit No.: 3 g 6 Yo
Tax-Map District: 1000 Section: R G. Block: Lot:_,
*BRIEF DESCRIPTION OF WORK(Please Print Clearly) _ . V
(Please Circle All That Apply)
*Is job ready for inspection: YES NO. Rough In Final
*Do-you need a Temp Certificate: YES! NO
Temp Informational a
*Service Size: 1 Phase 3Phase 100 150 200 300 350 400 Other
*New Service: Re-connect Underground Number of Meters Change of Service Overhead
Additional Information: PAYMENT DUE WITH APPLICATION
.82=Request for Inspection Form C
I. .
s
*pF SOUryolo
Town Hall Annex Telephone(631)765-1802
54375 Main Road Fax(631)765-9502
P.O.Box 1179
C/2 •
Southold,NY 11971-0959 'Q
reonTY,�
August 29, 2014
BUILDING DEPARTMENT
TOWN OF SOUTHOLD
West Creek Builders
PO Box 256
New Suffolk, NY 11956
Re: Tanzi, 150 Shore Lane, Peconic
TO WHOM IT MAY CONCERN:
The Following Items(if Checked)Are Needed To Complete Your Certificate of Occupancy:
✓ Application for Certificate of Occupancy. (Enclosed)
Wlctrical Underwriters Certificate.
A fee of$50.00.
` Final Health Department Approval.
✓ Plumbers Solder Certificate. (All permits involving plumbing after 4/1/84)
Trustees Certificate of Compliance. (Town Trustees#765-1892)
Final Planning Board Approval. (Punning#765-1938)
Final Fire Inspection from Fire Marshall.
Final Landmark Preservation approval.
Final inspection by Building Dept.
Final Storm Water Runoff Approval from Town Engineer
BUILDING PERMIT — 38640 — Basement Alterations
•
4 `
PIAT PLAN
LOT 15
M" OF
RICHUOND SHORES AT- PECONIC
fxf tic SM roLm OWDOM 20. IM
�J SITUATED Ar
PECONIC
"IVTOWN OF SOUTHOLD
SUFFOLK COUNTY, NEW YORK
S.C. TAX No. 1000-86-01-4.15
SCALE 1'=40'
J6
r+ y a OECEMOM 21. 1999
AREA = 27,396.03 q. tt.
0.622JPM
Zell
KA'rlM flRa
O. �[AIOCAII I= sir1�MICT C�IMf
.10
ASA-
VIP
40
J680Ph A.
• C�
W IK L� SUMeytw
i MW - QwrrA� i
1 �
PPIP,
62'-10 13/16"
DATE � P L
U.!1BI�'t�!
n �� �� ALL PLU" .;IiV�4Y'r;v;E
2'-915/16" 2'-915/16" ,1�
20'-6 1/2 6-4 27 -0 1/4FES __ d•_....4, .. _. / �— &WATER LINES NEED
NOTIFY DUIiLOr, TESTING BEFORE C0V .;i!I`d,;a
765-1,802 8
FOLLOWING
pc Tl� 1. FOUNDA.T 1';`N -o
FOR POURED
ROUGH-FRAM NG,P[11
STRAPPING, ELECT� IGAW h PLUMBER CER TIFICATf?��;'�
3. INSULATION
FINAL coNsrR!�cT!or,! �:: DL EC: ON LLEA D C.CiVTENT SEFjj-,;�
MUST BE COMPLETE FOR C 0. CERT%i=/GATE OF
ALL CONSTRUCTION SHALL I'�,1FET-1-I"_ OCCUPI,LSC'
SOLDER USED IN
EOU;REMENTS OF THE COLDES OF i W
' ORI<STATE. NOT RESPd�'i�LE FGR SUPPLYSYST'EMCfii',',`, ,)
DESIGN OR CONSTRUCTION ERRORS EXCEED 2110 OF 15/ 1.l �
00 10'-7 7/8"
\
♦T�/�
\1!
W
E.-WEST CREK
Al
'DESIGN BUILD REMODEL
. . . : ..........::.:.:..:
58'-2 5/8"
DESIGN:
T
LO
West Creek Builders, LLC
PO Box 256
EXISTING BASEMENT
1800 so FT _ New Suffolk, NY 11956
BOILER oo _ T 631 .734.8416
C� CD
\
(0 LVL GIRDER&COLUMNS LO
C'7
�_
CD
rT
O
C\I �
ENGINEER:
� T
T
00
HOT WATER co James J. Deerkoski, P.E.
TANK
0 260 Deer Drive
co
ELECTRICAL SERVICE Mattituck, NY 11952
PANEL
CV
\
UP
LVL GIRDER COLUMNS
O O O 01
REVISIONS / ISSUE:
77
777
Permit Set 01 .08.14
Cq
CD
32'-8 1/8"LO iX
til
U-) 1 1,
..: PROJLO
.
T Residence
anzi
'sem Basement Remodel
WATER SERVICE
150 Shore Lane
Peconic, NY 11958
2'-10 7/8"
LEE 20'-6 1/2" 4'-4 5/8" 13'-2 1/4" 13'-6 3/8" 5 'F NEW
P�
. D-- 0,p� DRAWING:
62'-10 13/16
*
Uj EXISTING FLOOR PLAN
Uj
Ul
EXISTING BASEMENT FLOOR PLAN °A�0 4 -2� ��� LEC
_SSI,
SCALE : 1 4" = V-011
PROJECT NORTH �
INTERIOR PERIMETER WALLS: NEW BASEMENT ENTRANCE:
1) 1" RIGID EPS FOAM ADHERED TO EXISTING CONCRETE WALLS 1) 8" THICK POURED CONCRETE FOUNDATION ON 16"X8" CONCRETE
FOOTING.
2) 2X4 FRAMED WALLS AGAINST EPS FOAM
2) 4" CONCRETE LANDING AT TOP AND BOTTOM OF STAIRS
3) R13 BATT INSULATION IN WALL CAVITY
3) 4" DRAIN WITH GRATE TO 24" DRYWELL AT BOTTOM LANDING
4) 1/2" MOISTURE RESISTANT DRYWALL
4) NON-SLIP CONCRETE STAIRS TO GRADE WITH HANDRAIL
5) ALL BOTTOM PLATES TO BE PRESSURE TREATED
5) 36" HIGH GUARD RAIL ON TOP OF CONCRETE WALL
6) RIGID EPS FOAM AT ALL RIM BOARDS NEW BASEMENT
ENTRANCE
16'
FLOORING:
1) 3/4" RIGID EPS FOAM ABOVE EXISTING SLAB. TAPE ALL SEAMS ' — — — — — — — --- — — — —
WINE CELLAR
2) 3/4" T&G PLYWOOD SUBLFLOOR SCREWED TO SLAB — — — — —
1 coo
WEST CREED
3) FINISHED FLOORING REF
9' RAIN
D
-915/16" � UP °
BAR I I DESIGN ( BUILD REMODEL
SINK
•E: F• - 3069 _
V I
iww
I I �
- - -� - - - � DESIGN:
West Creek Builders, LLC
19'-4 11/16" PO Box 256
EGRESS o New Suffolk, NY 11956
WINDOW N VIDEO GAMING ROOM T 631 .734.8416
AND WELL (0 PLAY AREA
N
T'
N
_._.....
T 3�'-8 7/16" ENGINEER.
9969 IN O UND LATE
EXISTING COLUMNS James J. Deerkoski P.E.
1 - WALLS
4 260 Deer Drive
— ,
N — — — — — — — — — — — 13/4'�'
OSOFFITCfl Mattituck, NY 11952
FIRE RATED — — — — — — — — — Ch
DRYWALL
AT SHARED WALLS TV&BUILT-IN
FOR COMPONENTS M
UNFINISHED a\o
MECHANICAL ROOM o\0 ELECTR AL SERVICE
PANEL :. REVISIONS / ISSUE:
151-511—
U'
GRINDER PUMP P EXISTINGCOLUMN MECHANICAL Permit Set 01 .08.14
SUMP SYSTEM FOR — — —
BATH& BAR SINK O
O 24246BO O SOFFIT
- I I
2X6 WALL
- HVAC
L —J 00
8'-4" • -
EXERCISE AREA K '
BATH PROJECT:
2969 23'-2 5/8" Tanzi Residence
o
Basement Remodel
LO
r 150 Shore Lane
LINEN CLOSET M
N x . Peconic, NY 11958
a. :. ACCESS DOOR —
T
TO WATER SERVICE
9'-8 1/4"
0 NEIVDRAWING.
PROPOSED FLOOR PLAN
rn w
PROPOSED BASEMENT FLOOR PLAN �� ,� oA � 7 ���C�C1
PROJECT NORTH SCALE . 1/4 = 1'-011
PLAN CONTENTS:
BASEMENT REMODEL 1,475 SQ.FT.
DESIGN CRITERIA PRESCRIPTIVE AS PER N.Y.S. RESIDENTIAL CONSTRUCTION CODE
AND 1995 SBC HIGH WIND EDITION,WOOD FRAME CONSTRUCTION
MANUAL
FRAMING ELEMENTS AS PER FLOOR PLANS,CROSS SECTIONS AND GENERAL NOTES
DESIGN LOAD CALCULATIONS EXT.BALCONIES 60
(LIVE LOADS PSF) DECKS 40
ATTICS W/O STORAGE 10
ATICS WITH STORAGE 20
ROOF GROUND SNOW LOAD 45 NAILING SCHEDULE
ROOMS OTHER THAN SLEEPING 40
ROOMS SLEEPING 30 TABLE 3.1,INCLUDING 3.3 AND 3.9
STAIRS 40 1995 SBC HIGH WIND ADDITION WOOD FRAME CONSTRUCTION MANUAL
GUARDRAILS ANY DIRECTION 200 JOINT DESCRIPTION NAIL QUANTITY NAIL SPACING NOTES
EXPOSURE CATEGORY ROOF FRAMING
LOAD PATH SEE CONSTRUCTION AND WIND PATH CONNECTION DETAILS AND RAFTER TO TO PLATE 8'WALL:3-8d EACH RAFTER TOE NAIL
ROOF-FOUNDATION' GENERAL NOTES
NAILING SCHEDULE SEE GENERAL NOTES 10' WALL: 4- 8d EACH RAFTER TOE NAIL
CLIMATIC AND GEOGRAPHIC GROUND SNOW LOAD 45 LBS. CEILING JOIST TO TOP PLATE 8'WALL: 3 8d PER JOIST TOE NAIL
CRITERIA WIND SPEED MPH 120 10' WALL:4- Bd PER JOIST TOE NAIL
SEISMIC CATEGORY B
CEILING JOIST TO PARALLEL RAFTER SEE TABLE 3.7 EACH LAP FACE NAIL
WEATHERING SEVERE
FROST LINE DEPTH 3 FT. CEILING JOIST LAPS OVER PARTITION SEE TABLE 3.7 EACH LAP FACE NAIL
TERMITE MODERATE TO HEAVY COLLAR TIE TO RAFTER SEE TABLE 3.4 PER TIE FACE NAIL
DECAY SLIGHT TO MODERATE
BLOCKING TO RAFTER 2-8d EACH END TOE NAIL
WINTER DESIGN TEMP. 11
ICESHIELD UNDERLAYMENT REQUIRED AT ROOF<4:12 RIM BOARD TO RAFTER 2-16d EACH END END NAIL
FLOOD HAZARDS INONE WEST CREED.
WALL FRAMING
TOP PLATE TO TOP PLATE 2-16d PER FOOT FACE NAIL
TOP PLATES ATINERSECTIONS 4-16d JOINTS- EACH SIDE FACE NAIL DESIGN I BUILD I REMODEL
STUD TO STUD 2-16d 24"OC FACE NAIL
HEADER TO HEADER 16d 16"OC ALONG EDGES FACE NAIL
TOP OR BOTTOM PLATE TO STUD 2-16d PER 2X4 STUD END NAIL
3-16d PER 2X6 STUD END NAIL
CONSTRUCTION NOTES: 4-16d PER 2X8 STUD END NAIL
1) The information within this set of construction documents is related to basic design intent BOTTOM PLATE TO FLOOR JOIST, DESIGN
and framing details. They are intended as a construction aid, not a substitute for generally BAN DJOIST,END JOIST,OR BLOCKING 2-16d PER FOOT FACE NAIL
accepted good building practice and compliance with current New York State building West Creek Builders,LLC
codes. The General Contractor is responsible for providing standard construction details FLOOR FRAMING PO Box 256
and procedures to ensure a professionally finished, structurally sound and a weatherproof JOIST TO SILL,TOP PLATE,OR GIRDER 4-8d PER JOIST TOE NAIL
Completed product. BRIDGING TO JOIST 2-8d EACH END TOE NAIL New Suffolk, NY 11956
2) The General Contractor is responsible for ensuring that all work and construction meets BLOCKING TO JOIST 2-8d EACH END TOE NAIL T 631 .734.8416
current federal, state, county and local codes, ordinances and regulations, etc. These BLOCKING TO SILL OR TOP PLATE 3-16d EACH BLOCK TOE NAIL
codes are to be considered as part of the specifications for this building and should be LEDGER STRIP TO BEAM 3-16d EACH JOIST FACE NAIL
JOIST ON LEDGER TO BEAM 3-8d PER JOIST TOE NAIL
adhered t0 even if in variance with the plan. BAND JOIST TO JOIST 3-16d PER JOIST END NAIL
3) Dimensions shall take precedent Over scaled drawings. (DO NOT SCALE DRAWINGS). BAND JOIST TO SILL ORITOP PLATE 2-16d PER FOOT TOE NAIL ENGINEER:
4) The designer has not been engaged for construction supervision and assumes no
responsibility for construction coordinating with these plans, nor responsibility for ROOF SHEATHING James J. Deerkoski, P.E.
construction means, methods, techniques, sequences, or procedures, or for safety STRUCTURAL PANELS 8d 4'PERIMERTER EDGE ZONE-16"OC-6" AT PANEL 260 Deer Drive
precautions and programs in connection with the work. There are no warranties for a EDGESANDAT INTERMEDIATE SUPPORTS IN THE PANEL
specific use expressed Or implied in the use of these plans. 8d INTERIOR ZONE-16"OC-6"AT PANEL EDGES AND 12" Mattituck, NY 11952
J) Refer to the Window and Door schedule for exterior openings. AT INTERMEDEDIATE SUPPORTS IN THE PANEL FIELD
6) The General Contractor is to consult with the Owner for all built-in items such as FOR ROOF SHEATHING WITHIN 4'OF THE PERIMETER OF THE ROOF,INCLUDING 4'ON EACH SIDE OF THE ROOF PEAK,THE
4'PERIMETER EDGE ZONE ATTACHMENT REQUIREMENTS SHALL BE USED.
bookcases, shelving, pantry, closets, trims, etc.
CEILING SHEATHING
GYPSUM WALLBOARD 5d COOLERS 7" EDGE/10" FIELD
ELECTRICAL NOTES: REVISIONS / ISSUE:
1) All electrical work shall be performed by a licensed electrical contractor and fully meet the WALL SHEATHING
requirements of the National Electrical Code, The New York State Building Code, and all STRUCTURAL PANELS 8d WEDGE ZONE- 16"OC-6"AT PANEL EDGES AND 12"AT Permit Set 01 .08.14
INTERMEDEDIATE SUPPORTS IN THE PANEL FIELD
other applicable local codes and ordinances.
gd INTERIOR ZONE- 16"OC-6"AT PANEL EDGES AND 12"
2) All electrical work shall be approved by a qualified Underwriter. AT INTERMEDEDIATE SUPPORTS IN THE PANEL FIELD
3) Install smoke detectors and carbon monoxide detectors throughout as per Construction FIBER BOARD PANELS 7/16" 6d 3"EDGE/6"FIELD
Code, 25/32" 8d 3"EDGE/6" FIELD
GYPSUM WALLBOARD 5d COOLERS 7" EDGE/10" FIELD
HARDBOARD 8d 4'EDGE ZONE-16"OC-6"AT PANEL EDGES AND 12"AT
INTERMEDEDIATE SUPPORTS IN THE PANEL FIELD PROJECT:
HVAC NOTES: 8d INTERIOR ZONE-16"OC-6"AT PANEL EDGES AND 12"
1) Mechanical subcontractor is responsible for adhering to all applicable codes and safety AT INTERMEDEDIATE SUPPORTS IN THE PANEL FIELD Tanzi Residence
requirements.
2) HVAC subcontractor is to fully coordinate all system data and requirements with the FLOOR SHEATHING Basement Remodel
equipment Supplier. STRUCTURAL PANELS 1"OR LESS 8d 6"EDGE/12" FIELD 150 Shore Lane
3) HVAC subcontractor to provide final system layout drawing and submit it to the General NAILING REQUIREMENTS ARE BASED ON WALL SHEATHING NAILED 6 OC AT THE PANEL EDGE. IF WALL SHEATHING IS
Contractor and Owner for final review and approval. NAILED 3"OC AT THE PANEL EDGE TO OBTAIN HIGHER SHEAR CAPACITIES,NAILING REQUIREMENTS FOR STRUCTURAL Peconic, NY 11958
MEMBERS SHALL BE DOUBLED OR ALTERNATE CONNECTORS SUCH AS SHEAR PLATES,SHALL BE USED TO MAINTAIN LOAD
PATH. WHEN WALL SHEATHING IS CONTINUOUS OVER CONNECTED MEMBERS,THE TABULATED NUMBER OF NAILS
SHALL BE PERMITTED TO BE REDUCED TO 1-16d NAIL PER FOOT.
�
()Fw>- DRAWING:
* CONSTRUCTION NOTES
07
A3
Z � ktr
�S qtr.
NYS ENERGY COMPLIANCE
VENT VENT RESicheck Software Version 4.4.4
Compliance Certificate
EXISTING HOUSE MAIN Project Title: Tanzi Residnence - Basement Remodel WEST CREEK
TO SEPTIC SYSTEM
Energy Code: 2010 New York Energy Conservation
Location: Suffolk County, New York
Construction Type: Single Family DESIGN I BUILD I REMODEL
1 1/2 Project Type: Alteration
1 1/2 Conditioned Floor Area: 0 ft2
1 1/2 1 1/2 Heating Degree Days: 5750
BAR SINK Climate Zone: 4
LAV.
W.
C.
LAV.
Permit Date: DESIGN:
—c DRAIN PUMP
Construction Site: Owner/Agent: Designer/Contractor: West Creek Builders, LLC
SHOWER OR BATH 150 Shore Lane
Peconic,NY 11958 PO Box 256
4 GRINDER PUMP SYSTEM
INC L.HIGHLEVELALARM New Suffolk, 11956
Maximum UA: 146 Your UA: 136 T 631 .734.8416
RISER DIAGRAM
N .T.S. Envelope Ass>emblies ENGINEER:
Gross Cavity Cont. Glazing
Assembly Areaor -Value or Door UA
James J. Deerkoski, P.E.
Perimeter U-Pactor
Basement Wall 1:Solid Comcrete or Masonry 1,475 13.0 5.0 68 260 Deer Drive
Wall height:8.0'
Depth below grade:6.0' _ _y. Mattituck, NY 11952
Insulation depth:8.0'
Window 1:Vinyl Frame:Doluble Pane 32 0.300 10
SHGC:0.00
Door 1:Solid 20 0.300 6
PLUMBING NOTES: _
Ceiling 1: Flat Ceiling or Scissor Truss 475 30.0 0.0 52
1) All water supply, drainage and venting to be installed as per N.Y.S. Residential OF NES,
Construction Code. Compliance Statement. The proposed building design described here is consist w� 1 pecifications,and other calculations REVISIONS / ISSUE:
2 If wall studs plates or joists are cut out Burin installation for an plumbing related work submitted with the permit application.The proposed building has., designe o fc�fle 01 nergy Conservation Construction Code
, p j g y p g , requirements in REScheck Version 4.4.4 and to comply with the h anda re ids I' to the c k Inspection Checklist.
provide adequate bracing and plates to protect and secure the structure. Verify with state ���yt�o5u : • .. � � to ' Permit Set 01 .08.14
code and manufacturer's recommendation for maximum hole size and spacing permitted. � s
Name-Title Signatu Dat
,off° 07250)L
�O'ESSloNA
PROJECT:
Tanzi Residence
Basement Remodel
Project Title: Tanzi Residnence-Basement Remodel Report 01/09/14 150 Shore Lane
Data filename: C:\User,,s\West Creek\DocumentslREScheck\TanziResidenceBasement.rck Page 1 of 1 Peconic, NY 11958
E
�EOFNEh, DRAWING:
�
*�QJ Dr )�° CONSTRUCTION NOTES
m _ o: