Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
39035-Z
v`f`SU� FF01A'`' Town of Southold Annex 9/16/2014 � ' r P.O.Box 1179 54375 Main Road ' ► iF` Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 37151 Date: 9/16/2014 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 1625 Oaklawn Ave, Southold, SCTM#: 473889 Sec/Block/Lot: 70.-3-6 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this officed dated 7/2/2014 pursuant to which Building Permit No. 39035 dated 7/18/2014 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: ROOF MOUNTED SOLAR PANELS TO A SINGLE FAMILY DWELLING AS APPLIED FOR The certificate is issued to Alvarez,Roque&Alvarez,Cynthia (OWNER) of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 39035 08-04-2014 PLUMBERS CERTIFICATION DATED Authorized Signature TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE '$ SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 39035 Date: 7/18/2014 Permission is hereby granted to: Alvarez, Roque & Alvarez, Cynthia 1625 Oaklawn Ave Southold, NY 11971 To: install a roof mounted electric Solar Panel system as applied for At premises located at: 1625 Oaklawn Ave, Southold SCTM # 473889 Sec/Block/Lot# 70.-3-6 Pursuant to application dated 7/2/2014 and approved by the Building Inspector. To expire on 1/17/2016. Fees: SOLAR PANELS $50.00 CO -ALTERATION TO DWELLING $50.00 ELECTRIC $100.00 Total: $200.00 Building Inspector S Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be.filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings,property lines,streets,and unusual natural or topographic features. 2. Final Approval from Health Dept.of water supply and sewerage-disposal(S-9 form). 3. Approval of'eled-dcal installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the.solder used in system contains less than 2/10 of I%lead. 5. Commercial building,industrial building,multiple residences and similar buildings and installations,a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit'Planning Board Approval-of completed site plan requirements. 8. For existing buildings(priorto April 9,1957)"nen-conforming uses,or buildings and"pre-existing"land uses: 1. Accurate survey of property showing all property lines,streets,building and unusual natural or topographic features. 2. A property completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied,the Building Inspector`shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00,Alterations to dwelling$50.00, Swimming pool$50.00,Accessory building$50.00,Additions to accessory building$50.00, Businesses$50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy-$.25 4. Updated Certificate of Occupancy- $50.00 .5. Temporary Certificate of.Occupancy-Residential$15.00,Commercial $15.00 Date. New Construction: )) Old or Pre-existing Building: (check one) Location of Property• bal.S� �2 1 A. n� ide <�w 1 C)X House No. //�� Street Hamlet Owner or Owners of Property: ,.,, i ,� #qt . Suffolk County Tax Map No I000,'Section ' ' Block Lot Subdivision :.Filed Map. Lot: Permit No. Date of Permit. Applicant: Health Dept.Apprdval: Underwriters Approval: Planning Board-Approval Request for. Temporl�ry Certificate• Final Certificate: (check one) Fee Submitted:$ - pplicant Signature SO!/jyol Town Hall Annex Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 1179 C Q roger.riche rt(aD-town.southoId.ny.us Southold,NY 11971-0959 100UNTY,� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION Issued To: Roque Alvarez Address: 1625 Oaklawn Ave City: Southold St: NY Zip: 11971 Building Permit#: 39035 Section: 70 Block: 3 Lot: 6 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: Solar City License No: 51331-me SITE DETAILS Office Use Only Residential X Indoor X Basement Service Only Commerical Outdoor X 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures HID Fixtures Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Fluorescent Fixture Pumps Transformer Appliances Dryer Recpt Emergency Fixture Time Clocks Disconnect Switches Twist Lock Exit Fixtures TVSS Other Equipment: roof mounted 2.75 KW photovoltaic system to include, 12-Canadian Solar #CS6P-250px panels, 1-Solaredge#SE3000A inverter Notes: Inspector Signature: Date: Aug 4 2014 81-Cert Electrical Compliance Form.xls i pE SOUryo� H r\� TOWN OF SOUTHOLD BUILDING DEPT. v 765-1802 INSPECTION [ ] FOUNDATION IST [ ] ROUGH PLUMBING [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING / STRAPPING [ ] FINAL [ ] FIREPLACE A CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) LECTRICAL (FINAL) [ ] CODE VIOLATION [ ] CAULKING REMARKS: DATE 1 INSPECTOR r. walcity. August 13,2014 Attn: Ray Bremen Long Island RE: Installation Approval Letter Roque Alvarez Residence Project: 1625 Oaklawn Ave, Southold NY 11971 Permit No.39035 Job No.119149 To Whom It May Concern, On the above referenced project, the roof structural framing has been reviewed for additional loading due to the installation of the solar PV addition to the roof.The structural review,including the plans and calculations only apply to the section of roof that is directly supporting the solar PV system and its supporting elements. The capacity of the structural roof framing directly supporting the additional gravity loading due to the solar panel supports and modules had been reviewed and determined to meet or exceed the requirements in accordance with the 2010 Residential code (IRC) of New York State. Plans and calculations were stamped&signed with my professional engineer's seal. The work has been completed in accordance with the manufacturer's specifications and provisions of the approved permits of the applicable code. Should you have any further questions .rements pertaining to this project,please do not hesitate to contact me. -- Of NifM►Y Since ,`p�� N�►. O Hussein A. Kazan,P.E. Project Engineer 3055 Cleamew Way San Mateo.CA 94402 T(650)638-1028 (888)SOL-CITY (650)638.1029 SOLARCITY.COM FIELD INSPE ON REPORT DATE COIVmmS FOUNDATION(IST) • .7r ••7r•Nrr7NN7NN..rrrrrr c FOUNDATION(IND) O rA ROUGH E AM[ING& y PLUMBING Q y INSULATION PER N.Y. STATE ENERGY CODE FINAL , • tiY G o rn 1 . o b BUILDING PERMIT APPLICATION CHECKLIST -1VIENT Do you have or need the following,before applying? Board of Health . iY 11971 4 sets of Building Plans X65-1802 Planning Board approval 1) 765-9502 _ Survey .,oldTown.NorthFork.net PERMIT NO. h3,5 Check Septic Form N.Y.S.D.E.C. Trustees C.O. Application Flood Permit Examined ' ,20 Single& Separate Storm-Water Assessment Form Contact: CcLt Ot7K Approved 1 ,20Mail to: ` ok-gLr Ci f / - ly— Skr�P Disapproved a/c n�] rn Mm- Pa- DV Phone:" PV A-)4— 7--7 Expiration (�,201A AUL -2 2014 Building Inspector si )G. GFPT. APPLICA IT Date SI C( , 20 7 INSTRUCTIONS a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans, accurate plot plan to scale. Fee according to schedule. b. Plot plan showing location of lot and of buildings on premises, relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e. No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize, in writing,the extension of the permit for an addition six months. Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York, and other applicable Laws,Ordinances or Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances, building code, housing code,and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. C:;�Kv MM (Sgnature of applicant or name, if a corporation) m TLr- li 1-Ci v,n per,(,l\!Iailing address o ,pj ligcan State whether applicant is owner, lesse agent; rchitect, engineer, genera contractor, lectrician, plumber or builder 0 /'M-(Y-4e1t7n Name of owner of premises�Q�' Lip AI ua r Z_ (As on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer (Name and title of co orate officer) Builders License No. c�b Plumbers License No. Electricians License No. ,j 3?y —m F Other Trade's License No. 1. Location pfflland on which proposed work will be done: (� tiazz House Number Street <<-1. t!;4Hiaimnle ' its;• ;ti�7;,r.'^!4 County pTax Ma No. 1000 Section Lot 9c, .ra^ ..staiO nolxxrmmo3 kM Subdivision Filed Map No. 2. State existing use and occupancy of premises and intended use and occupancy of proposed constru. a. Existing use and occupancy b. Intended use and occupancy 3. Nature of work (check which applicable): New Building Addition Alteration Repair Removal Demolition Other Work 4= D V\P�-� _ep�a quxi+ (Description) 4. Estimated Cost Fee I a.OU (To be paid on filing this application) 5. If dwelling, number of dwelling units Number of dwelling units on each floor If garage, number of cars 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of existing structures, if any: Front Rear Depth Height Number of Stories.. Dimensions of same structure with alterations or additions: Front Rear Depth Height Number of Stories 8. Dimensions of entire new construction: Front Rear Depth Height Number of Stories 9. Size of lot: Front Rear Depth 10. Date of Purchase Name of Former Owner 11. Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law, ordinance or regulation? YES NO 13. Will lot be re-graded? YES NO Will excess fill be removed from premises? YES NO Sp�\01� �,�Q 14. Names of Owner of premises Address ���.J�f`Q�L1[x W+�COLne No. �1\) Name of Architect '14%v AddressRa;"L':! ay„� �Phone No Name of Contractor So\a r Cris Address 7,rPhone No. 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO * IF YES, SOUTHOLD TOWN TRUSTEES & D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey,to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. 18. Are there any covenants and restrictions with respect to this property? * YES NO * IF YES, PROVIDE A COPY. STATE OF NEW YORK) SS: COUNTY OF ) ocnn being duly sworn, deposes and says that(s)he is the applicant ( ame of individual signing contract)above named, (S)He is the rk44at (�-��� (Contractor, Agent, Corporate Officer, et of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be performed in the manner set forth in the application filed therewith. Sworn to before me this q day of MW �RWTANDREW MORSc•SAM � 1 Notary Public NO InSuttoikCou�2O Signature of Applicant My Commission Espins Oct 2 Julffl n014 11,18,23 AM SolarCity 8312340148 212 Scan A. Russell °s°mir STI.C.".)KN[ ATTER SUP)MV WOR MANAGEMENT satrrxOrnrowN HALL.r.4.Box xa 'own of So Athol d .43493 Main Rand-SOU MOLD,NEIN XORK 11= .C&4Y=236 M STOg��A'.r MANAGFN.[ENT-WORK SMET (TO BE COMPLETSD BY THE APPLICANT) DOES .TM PROD= AWOLVE ,A»Y OF THE F4UDWIEa-� N X tMCALL THAT APPLY) i p R'A. Clearing, grubbing, grading or stripping of land which affects more than 5,000 square feet of ground surface. B. Excavation or filling involving more than 200 cubic yards-of material within any parcel or any contiguous area. C. Site preparation on slopes which exceed 10 feet vertical rise to �. 100 feet of horizontal distance. []( ,D. Site preparation within 100 feet of wetlands, beach, bluff or coastal ! erosion hazard area. ! El CIE. Site preparation within the Ane-hundre&« ear floodplain as depicted on FIRM Map of any watercourse. l F. Installation of new•or resurfaced Impervious surfaces of 1,000 square ' feet or more, unless prior approval of a Stomwater Management i Control flan wigs received by the Town and the proposal includes i, in-kind replacement of impervious Surfaces. •• • .rwl.Iw1\NNYIII\//AAlwl.r. —.HAM/M NyYYYy11.lYN1.1_r.r.l\Y\/.I— _Y r I . Y NI!Y..r• .Y• V 11.1 MI.w • ..l.r. I ...w_.r.nM....�—� � • ���•,.r'��T«_...+w�M\M.. _WI\�—rr—Y.r11/ 1\N... r I. \r.. ..1_YY I ..Y.N.M.u.....W.MMw Ir ya►snowed NO to all of fa quostlw above,SWI t=ploie Me A pplltwit tuxtian below with ytanr Alamo, ,Sipatura,Contaet Ynibrio nate & County Tax Ma Ntratlaoei Chaptor 288 don not!By to Your p ttaL it you ateW01114%T"to one or man of the&W%planes subwK Two aimas of a starimiaar Adamement Castrol Haat and It completed Cho*l int 1►otts to the midjto pe arlmatwlyyt�7ya�{ur E# 1'armtt ott3lwa. ACq, nt�r V+oponr Owner,Deftn PWOO aei,Aswi�t onM ator Otrnr) ; .10 NAME , Srsiwn los _U_ +gIY6 MR BQ) G DEPAli'1MEN' T US C')NL sass Cen�ncl rnrarnp�iw C/� ' Reviewed 0, �7 Y Pr Fi 1... laF9-7 nr�0e n Work [3';7A7ppj oved.. hate_ for Processing 6ulldlitg Permit. LOU 5tormwater Management Control Plan Not Required. .. �_. � .. Storrnwarer Managemcm Control Pian ie Required. © (Forward to Engineering Depprimem for Review.) FORM " SMCP_TOS MAY 2014 11 JI 4 M.1 �o��OF SOUryol Town Hall Annex J O Telephone(631)765-1802 54375 Box Road G ,,aaxx(631)76�. 5Q$ O 179 • g f.fichert TOWr1.SOUIIIOId nV us Southold,NY 11971-0959 BUILDING DEPARTMENT TOWN OF SOUTHOLD APPLICATION FOR ELECTRICAL INSPECTION REQUESTED BY: Date: Company Name: Name: License No.: Address: Phone No.: JOBSITE INFORMATION: (*Indicates required information) *Name: *Address: *Cross Street: *Phone No.: � t _ �a.p Permit No.: 0 Tax-Map District: 1000 . Section: Block:__ Lot: *BRIEF DESCRIPTION OF WORK(Please Print Clearly) vy�o ev_ f I C � ,�: ,�„ Sot�� P.,no I STS_a\�rjap ��F�c �-vs 2,� u �.► �4c-s (Please Circle All That Apply) *Is job ready for inspection: YES/ NO Rough In Fina! `Do-you need a Temp Certificate: @�/ NO Temp Information(If needed) *Service Size: 1 Phase 3Phase 100 150 200 300 350 400 Other New Service: Re-connect Underground Number of Meters Change of Service Overhead Additional Information: PAYMENT DUE WITH APPLICATION 82-Request for Inspection Form G � /'�� TOWN OF SOUTHOLD PROPERTY RECORD CARD Id V1, OWNER STREET VILLAGE DIST.j SUB. LOT de RMER OWNER N E ACR. 7 4�m F �' ✓ - /1/ 5 ... ,,i S W TYPE OF BUILDING r.;� `a�-�-L.,c-g'�->t_t ,� ��f'/Y`/N �+.�^'. L�"'r .,,.,°tv�.;1-�.,,+��,s1 C•�s�t--� : �2 �l "'��11,,v�/ �►�'' RES. SEAS. VL. FARM COMM. CB. MICS. Mkt. Value O t"0(5f t b LAND IMP. TOTAL DATE REMARKS � 2 76 n LN r wBUD 12-111 7---C CPS 1' Cl £C"r-?c' i ; AGE BUILDING CONDITION NEW I NORMAL BELOW ABOVE FARM Acre Value Per Value Acre Tillable I FRONTAGE ON WATER Woodland ; FRONTAGE ON ROAD Meadowland DEPTH L a House Plot BULKHEAD Total ``� "`+ i " "' "" DOCK ■■■■M■■NEW M■■■I■■■■■■■■■ mom ■■■■■■■■■■■■■■■■■■■■■■■■ Foundation _ Both ®Basement Floors09 •. interior Finish • Jul/8/2014 11:18,23 AM SolarCity 8312340148 112 .,,,.So1arCiJL t?2;+Mutnr Parkway,Ste C Maupprsupi�r.WY 11788 t i0l,625.9,400 F 631)3:34.0140 SOLARCITY.COM FAX COMER TO Now Sue DATE 7/8/14 Company Town of Southold TIME 11,30am Fh4-111-NO 631.765-1802 �x ido. 631-765-9502 N0.OF PAGES 2 Iholufto Rover page FROM N.,— Kathleen Caiati REGARDING Compaq SolarCity Inc. Roque Alvarez Phone No. (631)625-9806 1625 Oaklawn Ave Fein No. (631)234-0146 Southold r, > m _ _ . . ... _, ,. .. � ,� ski ��i► µ � x ., irP : 4 , } �n i; 1 1' 1 a .i /J . d i , ,7r a 4 .� _ - 21 a s,D { ,u 1 . •► , r f. a f '® - ` STATE OF NEW YORK WORKERS'COMPENSATION BOARD CERTIFICATE OF NYS WORKERS' COMPENSATION INSURANCE COVERAGE In.Legal Name&Address of Insured(Use street address only) lb.Business Telephone Number of Insured (650)%3-5161 SolarCity Corporation 3055 dearview Way lc.NYS Unemployment Insurance Employer San Mateo,CA 94402 Registration Number of Insured 49-892777 Work Location of Insured(Only required if coverage is specifically limited to certain locations in New York State, i.e., a Wrap-Up Id.Federal Employer Identification Number of Insured Policy) or Social Security Number 02-0781046 2.Name and Address of the Entity Requesting Proof of 3a. Name of Insurance Carrier Coverage(Entity Being Listed as the Certificate Holder) Uberty Insurance Corporation 3b.Policy Number of entity listed in box"la" Town of Southold WA7-66D-066265-023 54375 Route 25 Southold,NY 11971 3c. Policy effective period _9/1/2013 to_9/1/2014 3d. The Proprietor,Partners or Executive Officers are ❑ included. (Only check box if an pamers/ofQeers ineltaded) X all excluded or certain partners/officers excluded. This certifies that the insurance carrier indicated above in box "3" insures the business referenced above in box "1a" for workers' compensation under the New York State Workers'Compensation Law.(To use this form,New York(NY)must be listed ander Item 3A on the INFORMATION PAGE of the workers'compensation insurance policy). The Insurance Carrier or its licensed agent will send this Certificate of Insurance to the entity listed above as the certificate holder in box"2". The Insurance Carrier will also notes the above certificate holder within 10 days IF a policy is canceled due to nonpayment ofpremiums or within 30 days IF there are reasons other than nonpayment of premiums that cancel the policy or eliminate the insured from the coverage indicated on this Certificate. (These notices may be sent by regular mail.) Otherwise,this Certificate is valid for one year alter this form is approved by the insurance carrier or its licensed agent,or until the policy expiration date listed in box 113c",whichever is earlier. Please Note: Upon the cancellation of the workers'compensation policy indicated on this form,if the business continues to be named on a permit,license or contract issued by a certificate holder,the business must provide that certificate holder with a new Certificate of Workers'Compensation Coverage or other authorized proof that the business is complying with the mandatory coverage requirements of the New York State Workers'Compensation Law. Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has the coverage as depicted on this form. Approved by: Theresa Fagan CA License K12887 (Print name of authorized representative or licensed agent of insurance carrier) Approved by: 9/10/2013 (Signature) (Date) Title: Client Service Coordinator Telephone Number of authorized representative or licensed agent of insurance carrier: 213-443-0775 Please Note. Only insurance carriers and their licensed agents are authorized to issue Form C-105.2. Insurance brokers are NOT authorized to issue it. C-105.2(9-07) www.wcb.state.ny.us Workers' Compensation Law Section 57. Restriction on issue of permits and the entering into contracts unless compensation is secured. 1. The head of a state or municipal department,board,commission or office authorized or required by law to issue any permit for or in connection with any work involving the employment of employees in a hazardous employment defined by this chapter,and notwithstanding any general or special statute requiring or authorizing the issue of such permits,shall not issue such permit unless proof duly subscribed by an insurance carrier is produced in a form satisfactory to the chair,that compensation for all employees has been secured as provided by this chapter.Nothing herein,however,shall be construed as creating any liability on the part of such state or municipal department,board, commission or office to pay any compensation to any such employee if so employed. 2. The head of a state or municipal department,board,commission or office authorized or required by law to enter into any contract for or in connection with any work involving the employment of employees in a hazardous employment defined by this chapter,notwithstanding any general or special statute requiring or authorizing any such contract,shall not enter into any such contract unless proof duly subscribed by an insurance carrier is produced in a form satisfactory to the chair,that compensation for all employees has been secured as provided by this chapter. C-105.2(9-07)Reverse ® Dog/09/ 2 ACCOREP 013 CERTIFICATE OF LIABILITY INSURANCE THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(les)must be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder In lieu of such endorsement(s). PRODUCER 0726293 1-415-546-9300 CONTACT NAME: Brendan Quinlan Arthur J. Gallagher & Co. PHONE FAX Insurance Brokers of California, Inc., License #0726293 415-536-4020 AIC No: 1255 Battery Street #450 ADDRESS: brendan quinlan@ajg.com San Francisco, CA 94111 INSURERS AFFORDING COVERAGE NAIC# INSURER A: LIBERTY MOT FIRE INS CO 23035 INSURED INSURER B: LIBERTY INS CORP 42404 SolarCity Corporation INSURER C 3055 Clearview Way INSURER D: San Mateo CA 94402 INSURER E: INSURER F: COVERAGES CERTIFICATE NUMBER: 35643658 REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR ADDL SUBR POLICY EFF POLICY EXP LIMITS LTR TYPE OF INSURANCE INSR Wn POLICY NUMBER DD DD/YYYY A GENERAL LIABILITY TB2661066265053 09/01/1 09/01/14 EACH OCCURRENCE $1,000,000 DAMAGE TO R X COMMERCIAL GENERAL LIABILITY PREMISES EaENTED occurrence $ 100,000 CLAIMS-MADE Fi-I OCCUR MED EXP(Any one person) $ 10,000 X Deductible: $25,000 PERSONAL&ADV INJURY $1,000,000 GENERAL AGGREGATE $2,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: PRODUCTS-COMP/OP AGG $2,000,000 X POLICY PRO LOC $ A AUTOMOBILE LIABILITY A82661066285043 09/01/1309701/14 COMBINED SINGLE LIMIT 1,000,000 Ea accident X ANY AUTO BODILY INJURY(Per person) $ ALL OWNED SCHEDULED BODILY INJURY(Per accident) $ AUTOS AUTOS NON-OWNED PROPERTY DAMAGE $ HIRED AUTOS AUTOS Peraccident) UMBRELLA LIA6 OCCUR EACH OCCURRENCE $ EXCESS LIAR CLAIMS-MADE AGGREGATE $ DED I IR TENTION S $ B WORKERS COMPENSATION WA766DO66265023 (Ded) 09/01/1 09/01/14 X WCSTATU- OrR TH- AND EMPLOYERS'LIABILITY B ANY PROPRIETOR/PARTNER/EXECUTIVE YIN NIA WC7661066265033 (WI Retro) 09/01/1 09/01/14 E.L.EACH ACCIDENT $ 1,000,000 OFFICER/MEMBER EXCLUDED? (Mandatory In NH) E.L.DISEASE-EA EMPLOYE $ 1,00 '000 If es,describe under 1,000,000 DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES(Attach ACORD 101,Additional Remarks Schedule,if more space is required) Proof of Insurance. CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE Town of Southold THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. 54375 Route 25 AUTHORIZED REPRESENTATIVE Southold, NY 11971 USA ©1988-2010 ACORD CORPORATION. All rights reserved. ACORD 25(2010/05) The ACORD name and logo are registered marks of ACORD djsan 35643658 AGENCY CUSTOMER ID: LOC#: ACCO O® ADDITIONAL REMARKS SCHEDULE Page of AGENCY NAMED INSURED Arthur J. Gallagher & Co. Insurance Brokers of California, Inc., License #0726293 SolarCity Corporation POLICY NUMBER 3055 Clearview Olay CARRIER NAIC CODE �EFF�ECIOATE: CA 94402 ADDITIONAL REMARKS THIS ADDITIONAL REMARKS FORM IS A SCHEDULE TO ACORD FORM, FORM NUMBER: FORM TITLE: WC Policy # NA766DO66265023 (Ded) includes Deductible: $150,000. ACORD 101 (2008/01) ©2008 ACORD CORPORATION. All rights reserved. The ACORD name and logo are registered marks of ACORD SUFFOLK CC"jTY DEPT OF LABOR. LICENSNJG b CONSUMER AFFAIRS WASTER ELECTRICIAN JASON KANE This WAWWW..e bearer is duly 50LAR crry ooxr licensed by the County of Suf & 51331-ME 03r 9=13 cr..a�en. � �vowwn lKiy01lZOt$ I SUFFOLK COUNTY DEPT OF LABOR, LICENSING d CONSUMER AFFAIRS HOMEIMPROVEMENT CONTRACTOR LICE wr SHAUN E CHAPMAN This fh8t ihwe rs rwric beer is duly sauna Cm Co pc"Tm liwn W the Cou*of Suffolk 52057-H oe/0tna13 08/01/M15 I Version#34.3 `5olarCit y 3055 Clearview Way,San Mateo, CA 94402 (888)-SOL-CITY (765-2489) 1 www solarcity com �..ibry��brto.cb.ou-sa.c May 13,2014 Hussein Kazan Project/Job# 119149 p>f NEW RE: CERTIFICATION LETTER ��a A. Y0 9P Project: ALVAREZ Residence e 1625 Oaklawn Ave Southold,NY 11971 To Whom It May Concern, A jobsite survey of the existing framing system was performed by a site survey team fro 'DS&Q.-MrkArNQ1;Pwas based on site observations and the design criteria listed below: DATE ' i B.P. # Design Criteria: ' FEE: B e�-L_.. -Applicable Codes= 2010 Residential Code of NY State,ASCE 7-05,and 200!NKMFY BUILDING DEPARTMENT AT -Risk Category=II 765-1802 8 ANI TO 4 PM FOR THE -Wind Speed = 120 mph,Exposure Category C FOLLOWING INSPECTIONS: -Ground Snow Load = 20 psf 1. FOUNDATION -TWO REQUIRED -Dead Load =10 psf(ALL MPS) FOR POURED CONCRETE 2. ROUGH-FRAMING,PLUMBING, STRAPPING, ELECTRICAL&CAULKING 3. INSULATION 4. FINAL-CONSTRUCTION & ELECTRICAL MUST EF'CCMPL E T F ALL CONSTRL'CTiOty SHAP- ^.`_-T THE REQUIREMENT;, OF T"hi C:)D� OF NEUV Note: Per IBC 1613.1; Seismic check is not required because Ss = 0.19994 < 0 ®��Ic� i� li"ig0�@ryL( B < D DESIGN OR CONSTRUCTION ERRORS. On the above referenced project,the structural roof framing has been reviewed for loading from the PV assembly on the roof.The structural review only applies to the section(s)of the roof that directly supports the PV system and its supporting elements.After this review it was determined that the existing structure is adequate to carry the PV system loading. I certify that the structural roof framing and the new attachments that directly support the gravity loading from PV modules have been reviewed and determined to meet or exceed requirements of the 2010 Residential Code of NY State. Please contact me with any questions or concerns regarding this project. Sincerely, Hussein Kazan, P.E. Civil Engineer Main: 888.765.2489,x9016 email: hkazan@solarcity.com 3055 Clearview Way Sats Mateo,CA 94402 T(650)638-1028 (888)SOL-CITY F(650)638-1029 solarcity.com 05.13.2014 SolarCity SleekMountTM PV System Version#34.3 Structural Design Software PROJECT INFORMATION &TABLE OF CONTENTS Project Name:I ALVAREZ Residence AHJ:I Southold Town Job Number:, 119149 Building Code: 2010 Residential Code of NY State Customer Name: ALVAREZ, ROQUE Based On: IRC 2006/ IBC 2006 Address: 1625 Oaklawn Ave ASCE Code: ASCE 7-05 City/State: Southold, NY Risk Category:j II Zip Code' 11971 Upgrades Req'd? No Latitude/ Longitude: 41.058818 -72.428735 Stamp Req'd? Yes SC Office: Long Island PV Designer:' Omer Ayubi Calculations: Grady Kou al EOR: Hussein Kazan P.E. Certification Letter Project Information, Table Of Contents, &Vicinity Map 2 Structure Analysis (Loading Summary and Member Check) 3 Hardware Design (PV System Assembly) 4 Note: Per IBC 1613.1; Seismic check is not required because Ss = 0.19994 < 0.4g and Seismic Design Category(SDC) = B < D 1 2-MILE VICINITY MAP 25 25 A 25 1625 Oaklawn Ave, Southold, NY 11971 Latitude: 41.058818, Longitude: -72.428735, Exposure Category:C CALCULATION OF DESIGN WIND LOADS -ALL MPS Roofing Material Comp Roof PV Systisrrt Type SolarCity SleekMountrm Spanning Vents No Hardware) Mount Type C Roof Slope 210 Rafter Spacing 16"O.C. Framing Type/Direction Y-Y Rafters Wind Design Code ASCE 7-05 Wind DW19n,Method Partially/Fully Enclosed Method Basic Wind Speed V 120120 mph Fig.6-1 Exposure Category - C Section 6.5.6.3 Roof Style Gable/Hip Roof Fig.6-11B/C/D-14A/B Mean Roof,Height h 25 ft Smictloin 6.2 Wind Pressure Exposure KZ 0.95 Table 6-3 Topographic Factor Ka 1.00 Semon 6.5.7, Wind Directionality Factor Kd 0.85 Table 6-4 ImportariM Factor I 1.0 Table 6-1 VelocityPressure qh =0.00256(Kz)(Kzt)(Kd)(V^2)(I) qn 29.6 f Equation 6-15 Ext. Pressure Coefficient U G -0.88 Fig.6-11B/C/D-14A/B Ext. t Down 0.45 Ffg,6-11 . 14 9 Desi n Wind Pressure P P=qh GC Equation 6-22 Wind Pressure U -26.0 psf Wind Pressure Down 13.4 psf ALLOWABLE STANDOFF SPACINGS Max Allowable Standoff Spacing Landscape 64" 39" Max AlloWSWe Cantilever Landscape 24° NA Standoff Confi uration Landscape Staggered Max SWOd f Tributary Area Trio 17 sf PV Assembly Dead Load W-PV 3 psf Net Wind lift at Standoff T-actual 417 lbs Uplift Capacity of Standoff T-allow 500 lbs 83.4% Max Allowable Standoff Spacing Portrait 32" (All Max Allow"Cantilever Portrait 15" NA Standoff Configuration Portrait Staggered Max Standoff Tributary Area Trlb 14 sf PV Assembly Dead Load W-PV 3 psf Net Wind Uplift at Standoff T actual -348 lbs Uplift Capacity of Standoff T-allow 500 lbs St DiNviand/Cavacity DCR 69.6% LOAM ITEMIZATION - ALL MPS a PV Module Weight(psf) 2.5 psf rdwMASAWNYANght 60, PV System Wei ht 3.0 psf 7 Roof Category Description ALL MPS Ding Type Comp Roof (2 Layers) 5.0 psf Re-Roof to 1 Layer of Comp? No Undedaymr nt Roofing Paper 0.5 psf Plywood Sheathing Yes 1.5 psf Board Sheathing None Rafter Size and Spacing 2 x 6 @ 16 in.O.C. 1.7 psf Vaulted Ce in9 No Miscellaneous Miscellaneous Items 1.3 psf Total Roof Dead Load 10 psf ALL MPS 10.0 Roof Live Load Lo 20.0 psf Table 4-1 Member Tributary Area At <200 sf Roof Slope 5/12 Tributary Area Reduction R, 1 Section 4.9 Sloped Roof Reduction Rz 0.95 Section 4.9 1111educedAadf I I-Wed Lr 4= R 4-2 Reduced Roof Lire Load Lr 19 ALL MPS 19.0 Ground Snow Load p9 20.0 psf ASCE Table 7-1 Snow Load Reductions Allowed? Yes Effective Roof Slope 210 Horiz.Dance from Eve to Ridge W 15.7 ft Snow Importance Factor IS 1.0 Table 1.5-2 Partially Exposed Snow Erre Factor Ce Partially Table 7-2 Snow Thermal Factor Ct All structures except as indicated otherwise Table 7-3 1.0 Minimum Flat Roof Snow Load(w/ pf-min 14.0 psf 7.3.4 ti<7.10 Rain-ori-Snow Surcharge) Flat Roof Snow Load pf pf=0.7(Ce)(Ct)(I)pg; pf>_ pf-min Eq: 7.3-1 14.0 psf 70% lot Surface Condition of Surrounding All Other Surfaces Roof fO°f 1.0 Figure 7-2 Design Roof Snow Load Over p.-mar=(q-roof)pr ASCE Eq:7.4-1 .SurroundingRoof p'-"00f 14.0 psf 70% LWd Surface Condition of PV Modules CS_p„ Unobstructed Slippery Surfaces Figure 7-2 Design Snow Load Over PV P� P.P.=(C.'.)Pr ASCE Eq:7.4-1 Modules 14.0 psf 70% COMPANY PROJECT WoodWorkso May 13, 2014 13:09 MP1&2.wwb Design Check Calculation Sheet WoodWorks Sizer 10.1 Loads: Load Type Distribution Pat- Location [ft] Magnitude Unit tern Start End Start End DL Dead Full Area No 10.00 (16.0)* psf SL Snow Full Area Yes 14.00 (16.0) * psf PVDL Dead Full Area No 3.00 (16.0) * psf *Tributary Width (in) Maximum Reactions (lbs), Bearing Capacities (lbs) and Bearing Lengths (in) : 16-02' 0' 1'-5" 14'-9.8" Unfactored- Dead 151 123 Snow 153 125 Factored: Total 304 248 Bearing: F'theta 466 466 Capacity Joist 611 349 Supports 586 586 Anal/Des Joist 0.50 0.71 Support 0.52 0.42 Load comb #2 #4 Length 0.50* 0.50* Min req'd 0.50* 0.50* Cb 1.75 1.00 Cb min 1.75 1.00 Cb support 1.25 1.25 Fcp sup 625 625 *Minimum bearing length setting used: 1/2"for end supports and 1/2"for interior supports MP1&2 Lumber-soft, S-P-F, No.1/No.2, 2x6 0-1/2"x5-1/2") Supports:All-Timber-soft Beam, D.Fir-L No.2 Roof joist spaced at 16.0"c/c; Total length: 16-0.2"; Pitch:4.5/12; Lateral support: top=full, bottom=at supports; Repetitive factor: applied where permitted (refer to online help); ❑ WoodWorks® Sizer SOFTWARE FOR WOOD DESIGN MP182.wwb WoodWorks®Sizer 10.1 Page 2 Analysis vs. Allowable Stress (psi) and Deflection (in) using NDS 2012 : Criterion Analysis Value Design Value Analysis/Design Shear fv = 40 Fv' = 155 fv/Fv' = 0.26 Bending(+) fb = 1301 Fb' = 1504 fb/Fb' = 0.86 Bending(-) fb = 59 Fb' = 886 fb/Fb' = 0.07 Live Defl'n 0.52 = L/328 0.95 = L/180 0.55 Total Defl'n 1 1.03 = L/166 1 1.43 = L/120 0.72 Additional Data: FACTORS: F/E(psi)CD CM Ct CL CF Cfu Cr Cfrt Ci Cn LC# Fv' 135 1.15 1.00 1.00 - - - - 1.00 1.00 1.00 2 Fb'+ 875 1.15 1.00 1.00 1.000 1.300 1.00 1.15 1.00 1.00 - 4 Fb' - 875 1.15 1.00 1.00 0.589 1.300 1.00 1.15 1.00 1.00 - 2 Fcp' 425 - 1.00 1.00 - - - - 1.00 1.00 - - E' 1.4 million 1.00 1.00 - - - - 1.00 1.00 - 4 Emin' 0.51 million 1.00 1.00 - - - - 1.00 1.00 - 4 CRITICAL LOAD COMBINATIONS: Shear : LC #2 = D+S, V = 236, V design = 220 lbs Bending(+) : LC #4 = D+S (pattern: sS) , M = 820 lbs-ft Bending(-) : LC #2 = D+S, M = 37 lbs-ft Deflection: LC #4 = (live) LC #4 = (total) D=dead L=live S=snow W=wind I=impact Lr=roof live Lc=concentrated E=earthquake All LC's are listed in the Analysis output Load Patterns: s=S/2, X=L+S or L+Lr, _=no pattern load in this span Load combinations: ASCE 7-10 / IBC 2012 CALCULATIONS: Deflection: EI = 29e06 lb-in2 "Live" deflection = Deflection from all non-dead loads (live, wind, snow...) Total Deflection = 1.00(Dead Load Deflection) + Live Load Deflection. Bearing: Allowable bearing at an angle F'theta calculated for each support as per NDS 3.10.3 Design Notes: 1. Woodworks analysis and design are in accordance with the ICC International Building Code(IBC 2012),the National Design Specification (NDS 2012), and NDS Design Supplement. 2. Please verify that the default deflection limits are appropriate for your application. 3. Continuous or Cantilevered Beams: NDS Clause 4.2.5.5 requires that normal grading provisions be extended to the middle 2/3 of 2 span beams and to the full length of cantilevers and other spans. 4. Sawn lumber bending members shall be laterally supported according to the provisions of NDS Clause 4.4.1. 5. SLOPED BEAMS: level bearing is required for all sloped beams. 6. The critical deflection value has been determined using maximum back-span deflection. Cantilever deflections do not govern design. ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES A AMPERE 1. WHERE ALL TERMINALS OF THE DISCONNECTING AC ALTERNATING CURRENT MEANS MAY BE ENERGIZED IN THE OPEN POSITION, BLDG BUILDING A SIGN WILL BE PROVIDED WARNING OF THE CONC CONCRETE HAZARDS PER ART. 690.17. DC DIRECT CURRENT 2. EACH UNGROUNDED CONDUCTOR OF THE EGC EQUIPMENT GROUNDING CONDUCTOR MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY (E) EXISTING PHASE AND SYSTEM PER ART. 210.5. EMT ELECTRICAL METALLIC TUBING 3. A NA11ON ALLY—RECOGNIZED TESTING GALV GALVANIZED LABORATORY SHALL LIST ALL EQUIPMENT IN GEC GROUNDING ELECTRODE CONDUCTOR COMPLIANCE WITH ART. 110.3. GND GROUND 4. CIRCUITS OVER 250V TO GROUND SHALL HDG HOT DIPPED GALVANIZED COMPLY WITH ART. 250.97, 250.92(8) I CURRENT 5. DC CONDUCTORS EITHER DO NOT ENTER Imp CURRENT AT MAX POWER BUILDING OR ARE RUN IN METALLIC RACEWAYS OR Isc SHORT CIRCUIT CURRENT ENCLOSURES TO THE FIRST ACCESSIBLE DC kVA KILOVOLT AMPERE DISCONNECTING MEANS PER ART. 690.31(E). kW KILOWATT 6. ALL WIRES SHALL BE PROVIDED WITH STRAIN LBW LOAD BEARING WALL RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY MIN MINIMUM UL LISTING. (N) NEW 7. MODULE FRAMES SHALL BE GROUNDED AT THE NEUT NEUTRAL UL—LISTED LOCATION PROVIDED BY THE NTS NOT TO SCALE MANUFACTURER USING UL LISTED GROUNDING OC ON CENTER HARDWARE. PL PROPERTY LINE 8. MODULE FRAMES, RAIL, AND POSTS SHALL BE POI POINT OF INTERCONNECTION BONDED WITH EQUIPMENT GROUND CONDUCTORS AND PV PHOTOVOLTAIC GROUNDED AT THE MAIN ELECTRIC PANEL. SCH SCHEDULE 9. THE DC GROUNDING ELECTRODE CONDUCTOR SS STAINLESS STEEL SHALL BE SIZED ACCORDING TO ART. 250.166(B) & STC STANDARD TESTING CONDITIONS 690.47. TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT Vmp VOLTAGE AT MAX POWER W c WATT GE AT OPEN CIRCUIT VICINITY MAP INDEX 3R NEMA 3R, RAINTIGHT PV1 COVER SHEET PV2 SITE PLAN PV3 STRUCTURAL VIEWS PV4 UPLIFT CALCULATIONS LICENSE GENERAL NOTES PV5 THREE LINE DIAGRAM Cutsheets Attached 1. THIS SYSTEM IS GRID—INTERTIED VIA A UL—LISTED POWER—CONDITIONING INVERTER. 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. 3. SOLAR MOUNTING FRAMES ARE TO BE GROUNDED. 4. ALL WORK SHALL COMPLY WITH THE 2010 MODULE GROUNDING METHOD: * R.C.N.Y.S. AHJ: Southold Town 5. ALL ELECTRICAL WORK SHALL COMPLY WITH REV BY DATE COMMENTS THE 2008 NATIONAL ELECTRIC CODE. REV NAME DATE COMMENTS UTILITY: Long Island Power Authority (LIPA) 7;+ A CONTAINED L- THE INFORMATION HEREIN [(12) BER: JB-1 19149 0o ALVPREMISE AREZ, ROQUE DES01IP71ON: DM. CONTAINED SHALL NOT EXCEPT USED FOR THE ALVAREZ RESIDENCE Omer Ayubi �«�SolarCity. N BENERTOF ANYONE ALL ITT BE DISCLOSED IN�YM�OOLE ORCINMOUNTING SEEM: 1625 OAKLAWN AVE PART TO OTHERS OUTSIDE THE RECIPIENTS Mount Type C 3 KW PV ARRAY �r ORGANIZATION, EXCEPT IN CONNECTION MATH SOUTHOLD, NY 119713055 aeav�.MmY THE SALE AND USE OF THE RESPECTIVE CANADIAN SOLAR # CS6P-250PX 94402 SOLARCITY EQUIPMENT. MATHOUT THE VATTEN PAGE NAPE SHFET REV DATE Son L•(650)63B-1028 F(650)638-1029 PERMISSION OF SOLARCITY INC. REDGE SE3000A—US—ZB—U 6317658020 COVER SHEET PV 1 5/12/2014 (BBB)-SOL—CITY(765-2489)www. RY.� PITCH: 21 ARRAY PITCH:21 MPI AZIMUTH: 146 ARRAY AZIMUTH: 146 MATERIAL:Comp Shingle STORY: 2 Stories M PITCH: 21 ARRAY PITCH:21 O MP2 AZIMUTH:56 ARRAY AZIMUTH:56 MATERIAL:Comp Shingle STORY: 2 Stories D ;; ; '\ Inv ; ; Hussein Digitally signed by Hussein Kazan B DN:dc=local,dc=SolarCity,ou=SolarCity LaKazan Users,ou=Cranbury,cn=Hussein Kazan, email=hkazan@solarcity.com Date:2014.05.1410:24:49-04'00' MP LEGEND e 409 9a Q (E) UTILITY METER & WARNING LABEL INVERTER W/ INTEGRATED DC DISCO Front Of House lov & WARNING LABELS © DC DISCONNECT & WARNING LABELS NEA EM AC DISCONNECT & WARNING LABELS DC JUNCTION/COMBINER BOX & LABELS D DISTRIBUTION PANEL & LABELS 0 LOAD CENTER & WARNING LABELS �.� O DEDICATED PV SYSTEM METER O STANDOFF LOCATIONS — CONDUIT RUN ON EXTERIOR CONDUIT RUN ON INTERIOR 5+ ` — GATE/FENCE Q HEAT PRODUCING VENTS ARE RED r, � It 'I INTERIOR EQUIPMENT IS DASHED L._�- SITE PLAN Scale: 1/8" = 1' O1' 8' 16' F CONFlDENDIAL— THE INFORMATION HEREIN J08 NUMBER JB-1 19149 00 SolarCit BENEFIT OF SHALL ANYONEOIXCEPT saLARgTY INC., MouNTArc sYsmc ALVAREZ, ROQUE ALVAREZ RESIDENCE Omer Ayubi = NOR SHALL IT S DISCLOSED IN WHOLE OR IN Com Mount T e C 1625 OAKLAWN AVE 3 KW PV ARRAY ill y PART To OTHERS EXCEPT IN THE CONNECTION WT MODULES: SOUTHOLD NY 11971 3055 C��War ORGANIZATION, IXCEPT IN CONNECTION HATH � THE SALE AND USE OF THE RESPECTIVE (12) CANADIAN SOLAR # CS6P-250PX PAM NawE SHEET REV. DATE Son Mateo. %402 soLARaTY EOUIPMENr, IWTHOUr THE wRIT1ENT:(650)638-1026 F.(650)636-1029 PERMISSION OF SOLMCITY INC. "`OLA 6317658020 PV 2 5/12/2014 (666)-sa-cm(765-240)www.wlardty.com SOLAREDGE SE3000A–US–ZB–U SITE PLAN S1 S1 4" 4" '-5 13'-3" '-5 13'-5" (E) LBW (E) LBW B SIDE VIEW OF MP2 NTS A SIDE VIEW OF MP1 NTS MP2 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES MPJ X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES LANDSCAPE 64" 24" STAGGERED LANDSCAPE 64" 24" STAGGERED PORTRAIT 32" 15" PORTRAIT 32" 15" RAFTER: 2x6 @ 16" OC ROOF AZI 56 PITCH 21 ARRAY AZI 56 PITCH 21 STORIES: 2 RAFTER: 2x6 @ 16" OC ROOF AZI 146 PITCH 21 ARRAY AZI 146 PITCH 21 STORIES: 2 i C.].: 2x6 @16" OC Comp Shingle C.J.: 2x6 @16" OC Comp Shingle PV MODULE 5/16" BOLT WITH LOCK INSTALLATION ORDER & FENDER WASHERS LOCATE RAFTER, MARK HOLE ' ZEP LEVELING FOOT6 (1) LOCATION, RILL PILOT O HOLE. ��'�► � A. ZEP ARRAY SKIRT (4) (2) SEAL PILOT HOLE WITH ' ZEP COMP MOUNT C POLYURETHANE SEALANT. •�► ZEP FLASHING C (3) (3) INSERT FLASHING. (E) COMP. SHINGLE (4) PLACE MOUNT. ` (E) ROOF DECKING (2) C(5)1 INSTALL LAG BOLT WITH Q$ '�$► ,� 5/16" DIA LAG BOLT LOWEST MODULE) SUBSEQUENT MODULES SEALING WASHER. WITH SEALING WASHER INSTALL LEVELING FOOT WITH �l77 s (2-1/2" EMBED, MIN) (6) BOLT & WASHERS. (E) RAFTER STANDOFF CONnDENTIAL— THE INFORMATION HEREIN JOB NumBER: JB-1 19149 00 PREMISE ONNER DESCRIPTION. DESK;N: CONTAINED SHALL NOT BE USED FOR THE ALVAREZ, ROQUE ALVAREZ RESIDENCE Omer Ayubi ��irSO�afC�t�/. NOR SHALLITIT"B�EXCEPT I TMOR�N 10A'"� 1625 OAKLAWN AVE 3 KW PV ARRAY Com Mount T e C PART IZ OTHERS OUTSIDE THE RECIPIENT'S Moos: SOUTHOLD NY 11971 3OW q Way ORGANIZATION, EXCEPT IN CONNECTION WITH r THE SALE AND USE OF THE RESPECTIVE (12) CANADIAN SOLAR # CS6P-25OPX PAGE NAS [5i�v— REV oATE San Mateo,CA 94102 SOLARgTY EQUIPMENT, NATHWT THE WRITTEN INVERTER, T.(650)638-1028 F:(850)638-1029 I�MBSSION OF SOLARCITY INC. SOLAREDGE SE3000A-US-ZB-U 6317658020 STRUCTURAL VIEWS 3 5/12/2014 (888}-SOL-CITY(765-2489)www.sIarcRyc UPLIFT CALCULATIONS SEE SEPARATE PACKET FOR STRUCTURAL CALCULATIONS. CONHDENTIAL— THE INFORMATION HEREIN im Numn: JB-1 1914 9 00 PREMSE 099. DEMTION: GN: CONTAINED SHALL NOT BE USED FOR THE ALVAREZ, ROQUE ALVAREZ RESIDENCE Omer Ayubi � rSO�a�C�ty. BENERT OF ANYONE EXCEPT SOLARCITY INC.. MOUNTING SYSTEik . NOR SHALL IT BE OUTSIDE T IN WHOLE OR IN Com Mount T e C 1625 OAKLAWN AVE 3 KW PV ARRAY PART IZ OTHERS OUTSIDE THE RECIPIENT'S MOMIEs: SOUTHOLD NY 11971 �aea*w Way ORGANIZATION, EXCEPT IN CONNECTION WITH � THE SALE AND USE OF THE RESPECTIVE (12) CANADIAN SOLAR # CS6P-250PX SHEET: REV; DATE: Sm Mateo,CA 94402 SMARCITY EQUIPMENT, WITHOUT THE WRITTEN INWRTM PAGE NAME. SHEET- 638-1028 F:(6W)63e-1029 PERMISSION OF SOLARCITY INC. SOLAREDGE SE3000A—US—ZB—U 6317658020 UPLIFT CALCULATIONS PV 4 5/12/2014 (888)-SOL-CITY(765-24N)w.aelecitycom ROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND (N) ,#3 GEC TO (E) GROUND ROD Panel Number. Inv 1: DC Ungrounded INV 1 -(1)SOLAREDGE ## SE3000A-US-ZB-U LABEL: A -(12)CANADIAN SOLAR # CS6P-250PX AT PANEL WITH IRREVERSIBLE CRIMP Meter Number:24655742 Inverter, 3000W, 24OV, 97.57; w/Unifed Disco and ZB, AFCI PV Module; 250V 229.6W PTC, 40mm, Black Frame, MC4, ZEP Enabled Underground Service Entrance INV 2 Voc: 37,2 Vpmax: 30.1 INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER E 200A MAIN SERVICE PANEL E 20OA/2P MAIN CIRCUIT BREAKER Inverter 1 (E) WIRING 20OA/2P 3 SOLAREDGE SE3000A-US-ZB-U (E) LOADS z-71 SolarCity Ll L2 N 2 A 1 2OA/2P ---------- EGG DC+ DC' jA r-------------------------------------- � -- Stris)0f120nMP2.MP DC- DC- IEGC I ————————————--� I I I N I I —__ EGCIGEC — Z T— GEC TO 120/240Y SINGLE PHASE UTILITY sma I I I I EGC ON ROOF TO BE ROUTED WHERE NOT SUBJECT TO PHYSICAL DAMAGE. WHEN ROUTED SUBJECT TO PHYSICAL DAMAGE THE SIZE MUST BE INCREASED TO #6 SOLID BARE COPPER. Voc* = MAX VOC AT MIN TEMP /� y; Ol (I)SQUARE 1)S karD !A QM22��c"PV BACKFEED BREAKER e „ (1)oW SIRNGS.LIN ED�1NC� X DC ZO �2P !"� —(1) nhersalBBox Bracket: (PKG B] REDGE PV (12) PoSOLAwerBox Cp�t3rn0o-ax�3A0f�NMSH4,DC to DC, ZEP 1 AWG f10• THWN-2, elan (I)AWG f1Q. THWN-2.Block voc* =500 VDC Isc =15 ADC �7 (2)AWG/10. PV MIRE.Black voc* =500 VDC Isc =15 ADC O (1)AWG f10. THWN-2, Red OC I)AWG f10, THMN-2,Red Vmp =350 VDC Imp=8.46 ADC O l0"1—(1)AWG/6, Solkl Bare Capper EGC Vmp =350 VDC Imp=8.46 ADC III���(1)AWG 110. THWN-2, White NEUTRAL VmP =240 VAC Imp=12.5 AAC . 1)AWG f10. THMM-2..Green.. EGC. ....-0)Pc*it_Kit;.3/47.OAT. .... .. ... �l . . .. .... ........ .. . ... .. .... . . . . . . . . . . . . .. . . .. .. . . . . . . .. .... .. .. ...... .-_(1)AWG 18,.1FIWN-2,Prean . . 99P/GEC.-(1)Condu(It.Kit:.3/4'EMT...... .. .. CONFIDENTIAL— THE INFORMATION HERONJOB NUMBER JB-1 1914 9 O O PROM owNE� DESaaPTK W Ksm CONTAINED SHALL NOT USED FOR THE ALVAREZ ROQUE ALVAREZ RESIDENCE Omer Ayubi --ir5olarCity. BENEFIT OF ANYONE EXCEPT SOLARCITY INC., YOI111111G SYSIEM; ' �'•� NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 1625 OAKLAWN AVE 3 KW PV ARRAY PART To OUTSIDE THE RECIPIENTS RaMZANON, EXCEPT IN coNNEC71ON IATH MDUIsSOUTHOLD NY 11971 3055 Clearview War THE SALE AND USE OF THE RESPECTIVE (12) CANADIAN SOLAR # CS6P-250PX SHEET: REt DATE San Mateo,CA 9++02 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN IIVEIMR. P NATE T:(650)636-1028 F:(650)636-1029 PMSSION OF SOLARCITY INC' SOLAREDGE SE3000A—US—ZB—U 6317658020 THREE LINE DIAGRAM PV 5 5/12/2014 (666>_SDL-M(765-2+69)wowockrdtya«„ SolarCity SleekMountTM - Comp SolarCity SleekMountTM - Comp The SolarCity SleekMount hardware solution •Utilizes Zap Solar hardware and UL 1703 listed Installation Instructions is optimized to achieve superior strength and Zap CompatibleTM modules aesthetics while minimizing roof disruption and . Drill Pilot Hole of Proper Diameter for labor.The elimination of visible rail ends and •Interlock and grounding devices in system UL listed to UL 2703 Fastener Size Per NDS Section 1.1.3.2 mounting clamps,combined with the addition of array trim and a lower profile all contribute •Interlock and Ground Zap ETL listed to UL 1703 / Seal pilot hole with roofing sealant to a more visually appealing system.SleekMount as"Grounding and Bonding System" • Insert Comp Mount flashing under upper utilizes Zap CompatibleTM modules with •Ground Zap UL and ETL listed to UL 467 as � layer of shingle strengthened frames that attach directly to grounding device Place Comp Mount centered Zap Solar standoffs,effectively eliminating the need for rail and reducing the number of •Painted galvanized waterproof flashing upon flashing standoffs required. In addition, composition Install lag pursuant to NDS Section 11.1.3 •Anodized components for corrosion resistance shingles are not required to be cut for this with sealing washer. system,allowing for minimal roof disturbance. •Applicable for vent spanning functions r� Secure Leveling Foot to the Comp Mount using machine Screw • Place module i Components 5/16"Machine Screw Leveling Foot . Lag Screw Comp Mount . Comp Mount Flashing 0 y s�� �pM►�r ���� ® January r • January 2013 SofarCity. ry 2013 �O �� LISTED ~�>°`Sofa�'ty CS6P-235/240/245/250/255PX rj !� CanadianSolar Electrical Data Black-framed y STC cw-x35P -mp essP-245P cs6f,250a cseP-255P Temperature Characteristics Nominal Maximum Power(Pmax) 235W 240W 245W 25OW 255W Optimum Operating Voltage(Vmp) 29.8V 29.9V 30.OV 30AV 30.2V Pmax -0.43%/'C Optimum Operating Current(Imp) 7.90A 8.03A 8.17A 8.30A 8.43A Temperature Coefficient Voc -0.34%I'C _ _ Open Circuit Voltage(Voc) 36.9V 37.OV 37AV 37.2V 37AV Isc 0.065%PC _ Short CircuitCurrent(Isc) 8.46A 8.59A 8.7M 8.87A 9.00A NormalOperatingCellTemperature 45t2°C • ck-fr• s Module Efficiency 14.61% 14.92% 15.23% 15.54% 15.85% Operating Temperature -40°C-+85°C Performance at Low Irradiance Maximum system voltage 100ov IEC /600V UL Industry leading performance at low irradiation Maximum Series Fuse Rating 15A environment,+95.5%module efficiency from an Application Classification Class A irradiance of 1000w/m'to 200w/m' Power Tolerance 0-+5W (AM 1.5,25 C) Next Generation Solar Module Under Standard Test Conditions(8TC)ofiff"anceof1000W/m',spectrum AM 1.5 and call temperature of 25C NewEdge,the next generation module designed for multiple ftioCT -2 -gyp, 26Engineering Drawings types of mounting systems,offers customers the added Nominal Maximum Power(Pmax) 170W 174W 178W 181W 185W value of minimal system costs,aesthetic seamless Optimum Operating Voltage(Vmp) 27.2V 27.3V 27.4V 27.5V 27.5V appearance,auto groundingand theft resistance. optimum operating current(Imp) 6.27A 6.38A 6.49A 6.60A 6.71A Open Circuit Voltage(Voc) 33.9V 34.OV 34.1V 34.2V 34AV The black-framed CS6P-PX is a robust 60 cell solar module Short Circuit Current(Isc) 6.86A 6.96A 7.08A 7.19A 7.29A incorporating the groundbreaking Zap compatible frame. Under Normal Operating cell Temperature,Iffedlance of SM Wim',spectrum AM 1.5,ambient temperature 20C, The specially designed frame allows for rail-free fast wind speed 1 We I I I lid installation with the industry's most reliable grounding Mechanical Data system.The module uses high efficiency poly-crystalline Cell Type Poly-crystalline 156 x 156mm,2 or 3 Busbara Key Features silicon Cells laminated with a white back sheet and framed Cell Arrangement 60(6 x 10) with black anodized aluminum.The black-framed CS6P-PX Dimensions 1638 x 982 x40mm(64.5 x 38.7 x 1.57in) • Quick and easy to install - dramatically is the perfect choice for customers who are looking for a high Weight 20.5kg(45.2 lbs) reduces installation time quality aesthetic module with lowest system cost. Front cover 3.2mm Tempered glass Frame Material Anodized aluminium alloy • Lower system costs - can cut rooftop .1-Box IP65,3 diodes 42 installation costs in half Best Quality Cable 4mm2(IEC)/12AWG(UL),1000mm • 235 quality control points in module production Connectors MC4 or MC4 Comparable • Aesthetic seamless appearance - low profile • EL screening to eliminate product defects Standard Packaging(Modules per Pallet) 2gpcg with auto leveling and alignment • Current binning to improve system performance Module Pieces per container(40ft.Container) 672pcs(40'HO) • Accredited Salt mist resistant • Built-in hyper-bonded grounding system - if it's I-V Curves(CS6P-255PX) ! mounted,it's grounded Best Warranty Insurance • Theft resistant hardware • 25 years worldwide coverage j • 100%warranty term coverage ` Section A-A • Ultra-low parts count - 3 parts for the mounting • Providing third party bankruptcy rights 35.0 and grounding system • Non-cancellable i -__ • era Immediate coverage j Industry first comprehensive warranty insurance by • 1 AM Best rated leading insurance companies in the • Insured by 3 world top insurance companies world Comprehensive Certificates • Industry leading plus only power tolerance:0-+5W I • IEC 61215,IEC 61730, IEC61701 ED2,UL1703, • Backward compatibility with all standard rooftop and CEC Listed,CE and MCS ground mounting systems • IS09001:2008:Quality Management System ISO/TS16949:2009:The automotive quality Specifications included In this datesheet are subject to change without prior notice. • Backed By Our New 10/25 Linear Power Warranty management system Plus our added 25 year insurance coverage • IS014001:2004:Standards for Environmental About Canadian Solar management system Canadian Solar Inc.is one of the world's largest solar Canadian Solar was founded in Canada in 2001 and was 1 AddedV • QC080000 HSPM:The Certification for companies. As a leading vertically-integrated successfully listed on NASDAQ Exchange (symbol: CSIQ) in Value Fro HazardOUs Substances Re ulations manufacturer of Ingots,wafers,cells,solar modules and November 2006. Canadian Solar has module manufacturing f-% m Warranty g solar systems, Canadian Solar delivers solar power capacity of 2.05GW and cell manufacturing capacity of 1.3GW. • OHSAS 18001:2007 International standards for products of uncompromising quality to worldwide es% occupational health and safety customers. Canadian Solar's world class team of es a to is m ss REACH Compliance professionals works closely with our customers to provide them with solutions for all their solar needs. •10 year product warranty on materials and workmanship •25 year linear power output warranty www.canadiansolar.com EN-Rev 10.17 Copyright 0 2012 Canadian Solar Inc. • solar - • • ! solar=@9SolarEdge Power Optimizer Module Add-On for North America P300 / P350 / P400 SolarEdge Power OptimizerP300 P350 P400 Module Add-On For North America _ _ `for60`°"°" ""72-call '�r'd""°" INPUT _ 1 P300 / P350 / P400 RatedlnputDCPoweri' .... ...... .300 -350 4.. -w-. T T T Absolute Maximum Input Voltage(Voc at lowest temperature) 48 60 80 Vdc .. .. .. .. ... ....I .... ........_ MPPT Operating Range..... ........ 848 8 80 Vdc ISI • Maxim um Short Circuit Current(Isc).-_.- ....... ...� .... .. _. ... .. .... ..... ... 30 Adc Maximum DC Inpu[Current 12 5 Adc Maximum Efficiency 995 __.,, % .......... ..... ........... ........ ....._. ...... ._- _.._ .... Weighted Efficiency 98.8 % ..... ........ ._. .. ...... — ....__ .. .: Overvohage Category ____ ......_..... _ OUTPUT DURING OPERATION(POWER OPTIMRER CONNECTED TO OPERATING INVERTER)— _ --- -- — fi a _„ Maximum Output Current ,,.15, Ad°.... Maximum _ Output Voltage _ _ L– __ __ ____60_Y _– Vdc • OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF(__ -___ _-_ Safety Output Voltage per Power Optimizer----__ �_ 1 Vdc STANDARD COMPLIANCE EMC FCC Part15 Class R,IEC61000-6-2,IEC61000-6-3 ,,,,,,,,,,,,,,,,,,,,,,,,,,,, IEC62109-1(lass 11 safety)UL1741 ..,,,, ROHS _ ---- _________w.___ _____Yes_______ INSTALLATION SPECIFICATIONS ____ _______ _ ------------------------------------ -- – Maximum Allowed System Voltage �- 1000 Vdc ._....._.............................._. ._......................__.... ...........................--_--........ ____ --______.–_–_ ___------ Dimension (W x L x H) 141 x 212 x 40.5/5.55 x 8.34 x159 mm/in Weigh(including cables) 950/2.1 gr/Ib ... ... .. ....... ....... �. .. .._._. ... .. . ....... in Connector MC4/Amphenol/Tyco Output Wire Type/Connector _ ,.,... Double Insulated,Amphenol i Output Wire Leng[h.._..............__..... _....0.95/3;0.,.,, j-.. ..... ....... 12/ 9 m/h ........__....... _..3..__...._.__ j............. Operating Temperature Range ....._......_, -0(1-+85/-40-+185 'C/F,,. Protection RatingIP65/NEMA4 _ ._ ; i r Relidity ......._ ........ ..... .. ........ ......... .... . ...... -. %. a"e.Hum _.... 0 100 b+ s ��� t �'T �. �'�r F �`..,n a mnmarnoa.rau.moe�r uoa�4aww.sx pow.�aem.aw.ea. w - - PV SYSTEM DESIGN USING A SOIAREDGE THREE PHASE THREE PHASE 208V 4MV – -- — ---- EP •� r.,_ ,�"'-' INVERTER _ (V porlFBfOpt�LfliZit10F1 Faa4iS4Y : .. .. 10 i 18 r----- T Minimum String Leng[h(Power Optimizers) 8 .. I 25 25 50 Maximum Power rStrin L _.7.. _. ...... ...... 5250 12750 W •U to 24%more ...... ... ..... _... ...... - P � ertelgy� � ....g. � .. ... ....Yes i aximum tong engt ower p mrzers I SuDerier Y(�• ) Parallel Strings of Different Lengths or Orientations MkWMs all types of module Mismatch losses,from manufxturing tolerance to partial shading _. _......... _...... r rdadble system design for maximum space utilization Fast installation With a single bolt . Next generation maintenance with module4ml monitoring Module-level voltage shutdown for installer and f refghter safety USA - GERMANY - ITALY - FRANCE - JAPAN - CHINA - ISRAEL - AUSTRALIA www.solaredge.us solar " - Single Phase Inverters for North America solar , • or SE3000A-US/SE380OA-US/SE5000A-US/SE6000A-US/ SE760OA-US/SE1000OA-US/SE1140OA-US SE3000A-US I SE330OA-US I SES000A-US I SE6000A-US I SE76WA-US I SE10000A-US I SE11400A-US oUWUT SolarEdge Single Phase Inverters 9980 @ 208V Nominal AC Power Output 3000 3800 5000 6000 7600 11400 VA .......................................... ...... ................. ................ ................ .10000 @240V.................... ........... For North America 5400@2DBv 1.090@2DBV Max.AC Power Output 3300 4150 6000 8350 12000 VA 5450 @240V 10950 @240V ........... AC Output Voltage Min.-Nom.-Max.* SE3000A-US/SE380OA-US/SE5000A-US/SE6000A-US/ 183-208-229 Vac ... ...................................... ................ ............... ................. ................ ................ .................................... ........... AC Output Voltage Min:Nom:Max.' � � � � � � � SE760OA-US/SE1000OA-US/SE1140OA-US 211-240- 264 Vac .......................................... ................ ............... ................. ................ ................ .................................... ........... AC Frequency Min,Nom.:Max.* 59.3-60-60.5(with HI country setting 57:60-60:5) Hz ... ... .. .... . . .... . Max.Continuous Output Current 12.5 16 ..I,.21 @.240V.. _.....25• . . 32 ._42 @.240V,...,.....47.5 A GFDI 1 A Utility Monitoring,Islanding Protection,Country Configurable Yes Thresholds INPUT Recommended Max.DC Power•• 3750 4750 6250 7500 9500 1240014250 W 15TC1......... .................... .... .............. .......... .... ................ .. ............ . Transformer-less,Ungrounded Yes Max.Input Voltage500 Vdc '.. .......................................... .......................................................................................................................... ........... DC Input Voltajge................ 325 @ 208V/350 @ 240V Vdc 15.5 16.5 @ 208V 33..208V 30.5 @ 240V ,. Max.In utCurrent•a• 9.5 13 18 23 34.5 Adc p @.240V .......!: ......... ............................. ........... . ..... ..... ......... ......... ................ ................ .................................... .... ... ` - Max;Input Short Circuit Current...... ................................3Q...........,.........,..... 45 Adc I Reverse-Polarity Protection .....................................Yes......... Grourxl Fault Isolation Detection 600ko Sensitivi ty............... . Maximum Inverter Efficien 97.7 98.2 98.3 98.3 98 98 98 % ..............................�Y.......... ................ CEC Weighted EfficiencyEfficiency97.5 @ 208V 97.5 98 97.5 9797 @ 208V.5 97.5 % 9.. 240V 97.5 @.240V Ni htiimePowerConsumption <2.5 <4 W ADDITIONAL FEATURES Supported Communication Interfaces RS485,85232,Ethernet,ZigBee(optional) .......................................... .......................................................................................................................... ........... Revenue Grade Data,ANSI C12.1 Optional STANDARD COMPLIANCE „ Safe .........................................UL1741,UL36998,.UL3998,CSA22.2 ........... " Grid Connection Standards IEEE1S47 .............. .. ...... .. ...... .......... .. ....... x Emissions FCC part15 class B " INSTALLATION SPECIFICATIONS iIwi ` # i AC output conduit size/AWG ran�e ..................3/4"minimum/24-6 AWG ........,....3/4"minimum/8-3.AWG............. ........... €` z DC input conduit size/If of strings/ 3/4"minimum/1-2 strings/24-6 AWG 3/4"minimum/1-2 strings/14-6 AWG ............................ .... ................ ... ... ............ ...... ... .................... ............. ............... ........... Dimensions with AC/DC Safe 30.5 x 12. x 7 0.5 x 12.5 x 7- in .' C/ Safety 5 / 3 5/ 30.5x12.5x10.5/77Sx315x260 / t witch HxWxD 77 172 77 x mm .. „. ., .5......1........)....................... ..........5 x 315.z............�. .........5..315 x 191........ .. .. ........... ..................... ... ......... .. Weight with AC/DC Safety Switch..... ...........r'.1:2.��3?.......... ......... 547/24.7_ ... .. .. . ............. .. ...88.4/40.1. ................. ... .Ib/.kg... Cooking Natural Convection Fans(user re laceable) Noise....... .............. ......... ... ...................... ..<.25............................. .......................<50............... ....... .dBA .. p ... Min.-Max. per,..o.. ..ting Temperature e.... g �t, -13 to+140/-25 to+60(CAN version""-40 to+60) 'f/'C '@ are It.Of CrYpe:00 W24111.690.1i�flMnplience � � .Ran6e.................................. ............... .. ............... ............................................. ........ ..... ... r Protection Ratin6... ...............................................NEMA 3R . • ........................................................ ........... For other ....... regional settings please contact SolarEdge support. • �Smad,�ht and easy to Inst$ on provided bracket - ••Limited to 125%for Waborrs where the yearly average high temperature is above 77'F/25-C and to 13S%for locations where it is below 77-F/2S'C. Bulk-in For detailed informa"t,refer to htlDjA war&a a• -M odkn.„,.rrer ode edf l monitoring - : A higher cu"m source may be used;the inverter wig limit its input current to the values stated. 'O ••CAN P/Ns are eligible for the Ontario Fn and micmFrr(mkroFrr eat SEIIAOOA-US-CM). Internet connection through Ethernet or Wireless Outdoor and indoor installation Fbted voltage inverter,DC/AC conversion only Pre-assembled AC/DC Safety Switch for faster installation Optional-revenue grade data,ANSI C32.1 stnSPEC • USA-GERMANY-ITALY-FRANCE-JAPAN-CHINA-AUSTRALIA-THE NETHERLANDS-ISRAEL www.solaredge.us