Loading...
HomeMy WebLinkAbout38501-Z Town of Southold Annex 9/16/2014 P.O.Box 1179 54375 Main Road V �W.� Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 37156 Date: 9/16/2014 THIS CERTIFIES that the building ACCESSORY Location of Property: 54800 Route 25, Southold, SCTM#: 473889 Sec/Block/Lot: 64.4-16 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this officed dated 11/4/2013 pursuant to which Building Permit No. 38501 dated 11/12/2013 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: accessory screened gazebo with paddle fan as applied for. (screens are removeable) The certificate is issued to Internodal Inc (OWNER) of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 38501 7/8/2014 PLUMBERS CERTIFICATION DATED 12 9- Y-d ut riz ign ure TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE 'a/�,_•► �, SOUTHOLD, NY c` BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 38501 Date: 11/12/2013 Permission is hereby granted to: Internodal Inc PO BOX 1173 Southold, NY 11971 To: Construction of an accessory building in the required rear yard as applied for. At premises located at: 54800 Route 25, Southold SCTM #473889 Sec/Block/Lot# 64.-1-16 Pursuant to application dated 11/4/2013 and approved by the Building Inspector. To expire on 5/14/2015. Fees: ACCESSORY $206.40 CO -ACCESSORY BUILDING $50.00 Total: $256.40 Building Inspector Form No.6 TOWN OF SOUTHOLD �C' T t{ t�L✓T!�:. N BUILDING DEPARTMENT 9r 7 TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: I. Final survey of property with accurate location of all buildings,property lines,streets,and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal (S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1%lead. 5. Commercial building, industrial building,multiple residences and similar buildings and installations,a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings(prior to April 9, 1957)non-conforming uses,or buildings and"pre-existing" land uses: 1. Accurate survey of property showing all property lines,streets,building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00,Alterations to dwelling$50.00, Swimming pool$50.00,Accessory building$50.00,Additions to accessory building$50.00,Businesses$50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy- $.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy-Residential $15.00, Commercial$15.00 Date. New Construction: Old or Pre-existing Building: (check one) Location of Property: 15 C)(0 ( "SbVj House No. Street Ha let Owner or Owners of Property: i2wecC'C�/L?/�G�,/JJC�1 kPt5 e7— Suffolk County Tax Map No 1000, Section Block Lot Subdivision Filed Map. Lot: Permit No. b �� t Date of Permit. Applicant: Health Dept.Approval: Underwriters Approval: Planning Board Approval: Request for: Temporary Certificate Final Certificate: (check one) Fee Submitted: $ plicant rignature SO(/j�ol 0 Town Hall Annex Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 1179 G Q roper.riche rt(C7town.southoId.ny.us Southold,NY 11971-0959 �f 10 NT`I BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION Issued To: Intemodal Inc Address: 54800 Rt 25 City: Southold St: NY Zip: 11971 Building Permit#: 38501 Section: 64 Block: 1 Lot: 16 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: License No: SITE DETAILS Office Use Only Residential X Indoor Basement Service Only Commerical Outdoor X 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures HID Fixtures Service 3 ph Hot Water GFCI Recpt 4 Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Fluorescent Fixture Pumps Transformer Appliances Dryer Recpt Emergency Fixture Time Clocks Disconnect Switches 1 Twist Lock Exit Fixtures TVSS Other Equipment: GAZEBO-----------1-paddle fan / light Notes: Inspector Signature: Date: July 8 2014 81-Cert Electrical Compliance Form.xls TOWN OF SOUTNOLD BUILDING DEPT. 765.1802 INSPECTION [ FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING/STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) REMARKS: DATE INSPECTOR `�'� o � 6 TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTIO [ ] FOUNDATION 1ST [ ] ROUGH BG. [ ] FOUNDATION 2ND [ ] IN ATION [ ] FRAMING /STRAPPING [ FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ J FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (RO GH) [ ] ELECTRICAL (FINAL) REMARKS: DATE INSPECTOR rsf s 0 TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION I FOUNDATION I ST ROUGH PLUMBING FOUNDATION 2ND INSULATION FRAMING / STRAPPING FINAL FIREPLACE & CHIMNEY FIRE SAFETY INSPECTION FIRE RESISTANT CONSTRWTION FIRE RESISTANT PENETRATION ELECTRICAL (ROUGH) ELECTRICAL (FINAL) CODE VIOLATION CAULKING REMARKS: DATE '7, e,14 INSPECTOR�Z TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTI ] FOUNDATION I ST RO H PLUMBING FOUNDATION 2ND SULATION FRAMING / STRAPPING FINAL FIREPLACE & CHIMNEY FIRE SAFETY INSPECTION FIRE RESISTANT CONSTRUCTION FIRE RESISTANT PENETRATION ELECTRICAL (ROUGH) ELECTRICAL (FINAL) CODE VIOLATION CAULKING REMARKS: DATE ( GINI INSPECTOR • • It r t ROUGH , . . tt PLUMBING t INSUL ATION •D �W2 ADDITIONAL Cr t t: URMIr� I i► a TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD,NY 11971 4 sets of Building Plans TEL: (631)765-1802 Planning Board approval FAX: (631)765-9502 Survey SoutholdTown.NorthFork.net PERMIT NO,--- Check Septic Form N.Y.S.D.E.C. Trustees I Flood Permit Examined l l Z ,20_ Storm-Water Assessment Form Contact: Approved 20J Mail to: Internodal Inc. P O Box 1173,Southold NY 11971 Disapproved a/c Phone: (631)765 0037 Fxpiration ,20 1 E DFRG- , + ' 2013 PLICATION FOR BUILDING PERMIT Date November 1,2013 BLDG.DEPT. INSTRUCTIONS TOWN OF SOUTHOLD a.This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans,accurate plot plan to scale.Fee according to schedule. b.Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas,and waterways. c.The work covered by this application may not be commenced before issuance of Building Permit. d.Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. £Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date.If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize,in writing,the extension of the permit for an addition six months.Thereafter,a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk County,New York,and other applicable Laws,Ordinances or Regulations,for the construction of buildings,additions,or alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code,housing code,and regulations,and to admit authorized inspectors on premises and in building for necessary inspections. Internodal Inc. (Signature of applicant or name,if a corporation) P O Box 1173,Southold NY 11971 (Mailing address of applicant) State whether applicant is owner,lessee,agent,architect,engineer,general contractor,electrician,plumber or builder OWNER Name of owner of premises INTERNODAL INC. (As on the tax roll or latest deed) napjp!5ati:s;a;o� ratio a of duly authorized officer ice President signing for Internodal Inc. (Name and title of corporate officer) Builders License No. Suffolk Licence 6595 Plumbers License No. Electricians License No. Other Trade's License No. 1. Location of land on which proposed work will be done: 54800 Main Road(Route 25) Southold House Number Street Hamlet County Tax Map No. 1000 Section 64 Block 1 Lot 16 Subdivision Filed Map No. Lot 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy HOME b. Intended use and occupancy same PRE-FABRICATED 3. Nature of work(check which applicable): New Building GARDEN HouSEAddition Alteration Repair Removal Demolition Other Work (Description) 4. Estimated Cost $25,000.00 Fee (To be paid on filing this application) 5. If dwelling,number of dwelling units Number of dwelling units on each floor If garage, number of cars 6. If business,commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of existing structures,if any:Front Rear Depth Height Number of Stories Dimensions of same structure with alterations or additions: Front Rear Depth Height Number of Stories rf', $ lig 8. Dimensions of entire new construction:Front 14' Rear 14' Depth 19' Height 13'2"wo cupola/14'w cupola Number of Stories 1 9. Size of lot: Front Rear Depth 10. Date of Purchase Name of Former Owner 11.Zone or use district in which premises are situated MIXED:Hamlet Bus&Res/garden house will be in Hamlet Business zone 12. Does proposed construction violate any zoning law,ordinance or regulation?YES NO XXX already done already done 13.Will lot be re-graded?YES XXX NO Will excess fill be removed from premises?YES XXX NO 14. Names of Owner of premises Internodal Inc. Address P O Box 1173,Southold Phone No. (631)765 0037 Name of Architect Address Phone No Name of Contractor Address Phone No. 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland?*YES NO XXX * IF YES,SOUTHOLD TOWN TRUSTEES&D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? *YES NO XXX * IF YES,D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey,to scale,with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below,must provide topographical data on survey. 18.Are there any covenants and restrictions with respect to this property? *YES NO XXX * IF YES,PROVIDE A COPY. STATE OF NEW YORK) SS: COUNTY OF Suffolk ) JOSEPH STADLER being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, crJNNIB D.BUNCH (S)He is the VICE PRESIDENT(corporate officer) Notary Public,State of New York 1 BU61 85050 (Contractor,Agent,Corporate Officer,etc.) Qualified in Suffolk can comrn?'ssion Expires,April 14,2Mlo of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief;and that the work will be performed in the manner set forth in the application filed therewith. Sworn to before me this 1�--1 dayof KDVety- 20 Z3I Notary Public Signature of Applicant ��� hq, pf SO�jryolo Town Hall Annex Telephone(631)765-1802 '40"0" i s 54375 Main Road P.O.Box 1179 G Q roaer.richertCa own so �oIny us Southold,NX 11971-0959 BUILDING DEPARTMENT TOWN OF SOUTHOLD APPLICATION FOR ELECTRICAL INSPECTION 4. REQUESTED BY: Date: Company Name: /arc Name: d- A AA License No.: s- f . Address: Az s� �1 w Av Phone No.: 7J7� JOBSITE INFORMATION: (*Indicates required information) *Name: N t _rA)C ' '`Address: 9 0 6A o �tity i *Cross Street: *Phone No.: f Permit No.: 8S o 1 Tax-Map District: 1000 Section: Block: Lot: *BRIEF DESCRIPTION OF WORK(Please Print Clearly) �Lim 0 j (Please Circle All That Apply) i *Is job ready for inspection: YES/ NO Rough In Final *Do-you need a Temp Certificate: YES/ NO Temp Information(If needed) *Service Size: 1 Phase 3Phase 100 150 200 300 350 400 Other *New Service: Re-connect Underground Number of Meters Change of Service Overhead Additional Information: PAYMENT DUE WITH APPLICATION I 82=Request for Inspection Form f# 1�MA SHERMAN ENGINEERING&CONSULTING P.C. PO BOX 887 SHELTER ISLAND,IVY 1 1964 C� 5015 COTTON VALLEY CHRISTIANSTED,VI 00820 631.831.3872 ��P\NC & Project Notes: Internodal International Inc.Property,54800 Rt 25 Southold -Proposed Garden House Construction Matthew Sherman, PE of Sherman Engineering & Consulting (SECPC) has reviewed the Garden House plans and specifications provided by Vixen Hill Cedar Products (vixen Hill) on behalf of the property owner in addition to engineering and technical support documents as provided by Vixen Hill. I have reviewed the applicable information and have determined that they comply with minimum applicable requirements as set forth by the Residential and Energy Conservation Construction Code of New York State. A complete submittal of design and permitting information will include: 1. Plans prepared by Vixen Hill dated May 2013 (page 9) and June 2013 as annotated by SECPC. 2. Site specific building design criteria. The review does not include nor does it assume responsibility for the following: 1. Planning and lot placement of building on parcel. 2. Electrical connection to existing electrical systems on site. 3. The addition of mechanical, fuel gas, plumbing and electrical systems. Additions or alterations to any documents bearing the seal of a NYS licensed Professional Engineer are not permitted by NYS Education Law without the approval of the engineer of record. SECPC and its engineer's responsibilities extend no further than the review of an annotation to project documents as described herein. All documents discussed herein must be present and legible to be considered a true and complete set. :VeryglftnUfly s,rin Consulting,P.C. erman,P.E. CIVIL ENGINEERING DESIGN SITE PLANNING PERMITTING INTERNODAL INC. 54800 MAIN ROAD SOUTHOLD NY 11971 r t y 0,6 .✓ Pk s Vo a u g 8� J® , r It 72•3v • C s�50t 1 55' y BUILDING 15 21' <3 C> OUTSIDE DIMENSIONS N 77 37`3Q E. 100.2 ' a� ave C �... ..... _�.4 .. .,... W01F RO Ur L. GAMWN AND -W- AWi. GAAWON ? art► S. mvet3o s W. AW/F WAROW L SWW AIV HEUM U fl-H ALL CODES OF NEW Y0 K S-Tt"% "z_:- & TOWN CODES RETAIN STORM WATER RIJ36FF AS REQUIRED OF PURSUANT 2 OF THE TOWN CODE p Property of:Intemodal International Inc. 54M Route 25 acs am 1173 Buffing Planning tNY8 Residential BLAIding Code Lfflo1) Southold NY 11471 Floor Uve Load(Table R304.4) 40 pst Roof Live Loam(Tatem 8301.5) 16-W Ground Snow Load 45 t NOSED Bask Wlnd speed 12 mph APPROVLD AS WW Exposure Category(8301.21.4) a �b l High Wind(>410 mph)Deso Crfteris AF&PA'01 DATE: I l Z B.P.# �7✓ Seismic Design category B p D 1� ratherirrg SEVERE FEE �6 �� B' : Frost t.�1e Dealt 3 NOTIFY BUILDING 'EPARTM,ENT AT Tem*eMODMEAVY 765-1802 8 AM TO 4 PM FOR THE Dewy SUGHTA"ERATE FOLLOWING INSPECTIONS: W*rter Design Temperature 11°F J 1. FOUNDATION - TWO REQUIRED lee Sheiid Underlayrrwre REQUIRED Flood Hazards IN ACCORD W1 FEMA FOR POURED CONCRETE 2. ROUGH - FRAMING & PLUMBING 3. INSULATION 4. FINAL - CONSTRUCTION MUST 'UPANCY OR BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE JSE IS UNLAWFUL OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR WITHOUT CERTIFICATE y, DESIGN OR CONSTRUCTION ERRORS. OF OCCUPANCY =� t9SHERMAN ENGINEERING&CONSULTING P.C. 144 COMN VALLEY P4 BOX$481 CMUS'nAN ,"OW23 631.831-3672 mattrshermsnw=m Elongated CUPOLA GAZEBO STRUCTURAL SYSTEM solid base } y SERIES GHE,- 14B MODEL u . s (electncalopfierrra)} `� � `� � � (14'x Ig`, DC}UBhE—MER) Lumber Western Red CEDAR#1 (Cabinet) Shingles.Sh�nglesr p §y 9 9 4 A 5X/ 16"long! 1/2" thick or 16 oz. copper s i Removable Screen Inserts (top&bottom) x , Entry Door Lock Set n (Wright brass or dark bronze) , A Screened Trellis Skirt(6"or 12") E C Vt w4 HILL CEDARL)raPRODUCTS 1 I P0.8ox 18F- Elverson, PA 19520 Created by; Andrea Beringer Date:Jun 201:3 Model:G •T -423-2765 I SIZE&DIMENSIONS Kw.Swdon sod $ t ow TOO to- 04 Door t r PON to poftN _T66-7fir v ti� C z a yr .. ��...... �.. pft ' ... pov CUM jj 1. y 3 r me"t" 1 a � f a <. 3 r � tl L,-!J S} ams• '^n''w„„ 4.. F a XEN H LL CEDAR Draining: Z of I PRODUCT P0.8ox 109 - Elverson,,OA IWO Created by; Andrea Beringer Date:Jun 2013 Model: GHE-14B Inner Panel Gap 13/16' WALL PANEL Outer Panet Cap x g ,.; CONSTRUCTION 4 3f4'" 3" T _ �1r+eaded fihrtlUg}1- Od II PLKrED ROTO LOCK CONNECTS WALL PANEL TO POST. 4X4 t 47 I/V There are two(2)wall panels on each elongated side, joined by a MID POST without roto-tacks. r r yin � I A PU BASE Post&Threshold � � Connection b S turall�crea�� ..,.. WALT.PANEL SASE (2)4" Screws Mine II Gaulle Bottom (HOLE ON LEH�anerr i bottomccm of panel) Of Thresh 1d 3/4" t , nM B ` II I3 C NCRET SLA Anus 314"TO HEIGH' or WOOD FLOUR THRESHOLD 58 1C2" VIXEN HILL CE-DAR PROOV TS Drawing: 3 of 10 PO.Sax 38# - Elverson,PA r9520 Created by Andrea Beringer Date.Jun 2013 Model: G E-14 Inner Panel Cap 13/16,: Anel Cap Spacer DOUBLIE DOOR CONSTRUCTION 4 muter Papel Cap 3" Threaded-Through-Rod E , , y Strap Hinges(3/4" offset)and pintels(l 1/4 offset) from wrought steel w/black powder coating (top&bottom length 18" middle length 12") Upper Opening 8Q 1/2" Entrance opening(not incl. threshold) 0» ' 43» H' n Entry Key Loch Set(brass plated) available in dark bronze or bright brass (Z)4"Screws (hole " on left& " on right parcel side) Slide Bolt( solid bright brass)mounted on the inside - IILower on trip&bottom of left door Opening ;W W THRESHOLD e; 23 H MORRIS I Roto-Lock-System g 1/2" Threshold (pockets in past connect 8 I/2" b to roto-lock in wall panel) VIXEN HILL. CEDAR y� ,�+� .: Drawing.4 of 10 ov u�luw .s Elverson,PA F 9S20 Created by, Andrea Beringer f31 ,, ddl: GIBE 14'x 19° 000-423-2766 ,x t Grooved l fight F lure 4 Roof motion (Inax. it Gmoved Upper Fret Riser Groove Roof " Section k, . iapi4 „I III iP. Additional Options: Outlet posts (dual) Fan Control post#fi t 14-2 UF/B with ground Channel Posts (for custom wiring) Bidden Wire through Channeled Post Ele tflc Outlet wfswlitch& receptacle(GM, Note: For concrete slab use conduit Floor Board *zwgh void(see slob Instructions) w/pre-drrilled hale loft ,e i MILL CEDAR DrawlnW.5 of010 PR# CSVCTS x„ Created b Andrea Beringer Date:jun 2013 Madel. Elongated Gardenhouse W-423-2766 UPPER TIED. .-- M"TOP SOFFIT ROOF CONSTRUCTION #to '• X a"SCREWS(4 PER LATH) A,, INN, • 5/4"X 4"ROOF LATH `'N' toil 5S" IN ` • �. 671/2" '`•` THE CUPOLA IS CONNECTED CEDAR SHINGLE ' WITH STAINLE&S STEEL,SCREW OR r6 OZ.COPPER z X 4"ROOF JOIST FROM THE UNDER SIDE OF THE _ ROOF LATH, ELONGATED UPPER ROOF MODUS, `tl 514"X 71r6"STAINLES N IL STEEL STAPLES ! -651/4' `'` `'` rX6"TOIL SOFFIT `e �,; �'•. � 5"SHINGLE - , e REVEAL ' 514X4"FA�L�► BOARI3 1 UPPER FRET (4 X 4!)RISER 67 I/2" 2 X 4"ROOF JOIST 58" SHORT SIDE MR ! ! i { tilittitt 93" LONG SIDE (514 X 5/4")SPINDLE(2 X 311)RAIL (514 X 4°)FRET FRAMIs 5i4X4"FACIA$ RD *10 X 2"SCREWS 093/8"- VIXEN HILL" CEDAR PRODUCTS Drawing: 6 of 10 F0,8ox 389 «Elverson.PA 19320 Created by: Andrea Beringer Date:Jun 2013 Model: GHE-14B 32 ill' 2X6""ISP SOFF T LOWER TIER R CaNSTR CTION i 2X3!CENTER SU PO52 3/4" IN IXb" FACIA BOARD '"•.'^ 72 tt2" 93 314" #I4 X 2"SCREWS (S PER LA'S'H) 2X6"TOP SOFFIT 5/4"X 4""ROOF LATH .- 2 X b" ROO JOIST~ 561" 2x 2 X 6" 2X3 CENTER 52 314" MID JOIST SLIPPY) JOIS° IX6" FACIA BOARD 1333/4 VIXEN HILL CEDAR ODVC'TS Drawing. 7 of 10 0P ,80.x389 - l"nson, PA 19520 Created by: Andrea Beringer Date:Jun 2013 Model: GHE-14B; RC)OF ROOF TO POST ATTACHMENT MORTICE CONNECTION g 6•'E. RCX,)I` LATH 3 X 112"HOLES g v ROOFJOIST APPROX.20"APART FOR 3180 SS RODS IIT HOLE for 1 X 518 HOLE 3 7W x 318"SS ROD 3 LOAD (4 X 4")RISER &8"HOLE for . 5 3/8'x�SS ROC} METAL ANCHOR TAB ALL ROOF SECTIONS ROTC)LOCK ' s ARE SYSTEM PRE-SHINGLED � tbs y �ry ,q LL PANEL 4 X 1/2" HOLES APPROX.20"APART PC}ST FOR 3111"SS RODS 1 X 518"HOLE 40mm ROOFROOF SYSTEMLOAD RIDGED TRIANGULAR MODULES CONNECT TO FORM A � CONIC;ROOF SYSTEM.THE COMPRESSION RING IS INTEGRAL TO`rHE CONIC DESIGN AND ALLOWS,RESULTANT FORCES � 4 X 4'POST TO BE PERPENDICULAR TO GRADE, 95"TOTAL HEIGHT VIXEN HILL CEDAR ft0oucTB Drawn : 8 of 10 PO-Sax 8 . fiversop,PA r P520 Created by: Andrea Beringer Dace: Jun 2013 Model: GHE-14B UNDER-SIDE OF INNER*OUTERUNDER-SIDE OF INNER OUTER SECTION FOR SHORT SIDES SECTION FOR LONG SIDES FLOOR CON'NE(MONS 1/2"DECK EC:K CR �yS THROUGH HOLES BACK SUPPORT 3 Itz"DRCK SCREWS 2X3"Floor JOIST BACK SUPPORTz.V. SEMI JOIST 2X8"F'LOt�R BOARD a 130 114" zXS"FLOOR BOARD ROI"*IT SC3PI'C?R`i' 69" FRONT SUPPORT zX3�CE�•''i ER k SU PORTS BACK StIPPO r FROM'T SUPPORT � r p R � 44 S/S" , v * S 79 1/16" MEN TEA ORTS z L 34 7111v END VIEW OF FLOORANCHORING 44 SV' 6"X 3/80 ROD AND .•—BRASS CAP NUT TOP AND BOTTOM CENTER .< &NCHOR PLATES IIS"STE EL AINCHOR TAB 2X6"FLOOR BOARD 2W FLOOR BOART? jam, xX3"" FLOOR Jcllsrsl f" - 30 THREADER BOLT—. •—_— a.Y3'SEMI JOIST �y3 1113"STESEL ANGLE ANCHOR .-----_zX60FLOOR JOIST' 8 C.EI`vTER PIER mow,. i/a"ANCHOR BOLT : j DIAMETER PIER ' n tA,\ " a " TRELLIS : VIXEN HILL SIL EAR ' Drawing. 9 of 10 PRoc-r P ,ao 3e;- €verse►. A 19:520 �6 A t it a e i ger Date: May 2013 Model: 14'x 19" I SPECIFjCAmNS FOR THE CABINET MODELS (8xix'x x rxxS'AND jc¢xxg') PART I GENERAL I..I SCOPE.Tup.CONTRACTOR SHALL FURNISH AND INSTALL A WOODEN GAZSBO AS SHOWN ON PLANS AND f EREIN SPECIFIER AS$UPPLIED BY VIXEN HILL MFG.Co, INC.,OF ELvERsoN,PA I952o. PART 2 PRODUCT 2.1 WOOD MATERIALS. FOR CABINET GRADE SHALL BE FABRICATED FROM AIR-DRIED,#I OLD GROWTH &ROT RESISTANT WESTERN REIT CEDAR. ALL WOOD SHALL BE GRAIN SELECTED DURING IN-HOUSE MILLING FOR BEST APPLICATION AND SAFE USE. 2.2 ROOFING SYSTEM.SHINGLES SHALL BE OF OR EQUAL TO#1 PBRFEL'TION CLEAR HEART CEDAR AND PER THE FOLLOWING SPECIFICATIONS SX, t6" LONG, IJ2" THICK,TAPERED.ROOF LATH SHALL BE OFI-40 LESS THAN NET FINISHED SIZE IX3"WITH A5 11 sPAGING.ROOF SECTIONS SHALL BE COMPLETELY PRE-ASSEMBLED AND PRE-CUT,AND JOINTS BETWEEN ROOF SECTIONS SHALL BE SELF-SEALING TO PRE LURE CAPPING.CAULK IS RECOMMENDED TO BE USED AT THE itOOF JOIST. 2.3 SURFACE FINISH.ALL WOOD MEMBERS SHALL BE SURFACED FOUR SIDES.SURFACES DISPLAYING PLANER SKIPS OR SAW MARKS AFTER DRESSING SHALL BE LIMITED TO LESS THAN 25% OF SHOWN FACES. HAND CONTACT EDGES MAYBEROUNDED,CHAMFERED,OR EDGE-SHAPER FREE OF SPLINTERS AND SMOOTH TO THE TOUCH. ALL EXPOSED SURFACES SHALL BE PREPARED FOR MAXIMUM ACCEPTANCE OF OIL-WED FINISHES(OPTIONAL WITH ADDITIONAL COST). 24 HARDWARE.ALL ASSEMBLY&ANCHORING HARDWARE SHALL BE PROVIDED? CONCEALED ROTO-LOCI:s ARE BUILT INTO THE WALL PANEL.TIE THRTsADED Roos FOR THE PANEL CAPPING PIECES ARE OF GALVANIZER STEEL WITH STAINLESS STEEL CAP NUTS &WASHERS AND OF A FINISH TYPE TO CONCEAL ALL THREADS.ALL HARDWARE IN GROUND CONTACT SHALL BE OF STAINLESS STEEL FOR CABINET GRADE..NO NAILS SHALL BE REQUIRED OR PROVIDED.THE STRAP HINGES FOR THE DOOR(S)ARE MODE FROM ZINC-PLATED&POWDER-COATED STEEL WITH A FLAT AND SMOOTH FINISH. 2..5 ELECTRICAL.STANDARD FOR CABINET`GRADE,TVIE PRE:WIRED POST PROVIDES I IOV ELECTRICAL SERVICE THROUGH WIRE(14-2 UF/B WITH GRot;Nt?),THE POST HAS AN ELECTRICAL BOX WITH (CFI)RECEPTACLE AND LIGHT SWITCH.THE LIGHT FIXTURE IS SCREWED INSIDE THE CUPOLA FOR UP TO 50ONV STRENGTH. WIRES SHALL BE HIDDEN WITHIN THE COMPONENT PARTS THROUGH GROOVED ROOF SECTION AND CHANNELED POST.ALL ELECTRICAL COMPONENTS SHALL BE UL APPROVED. z.6 CONNECTIONS&ANCHORING.FACTORY MODULE CONSTRUCTION SHALL.INCLUDE POCKET JOINTS AND STAINLESS STEEL THREADED FASTENERS.ON-srrF jN TER- CONNECTION OF MODULES SHALL BE ACHIEVED USING THREADED RODS AND STAINLESS OR BRASS CAP NUTS AND WASHERS.ANCHORING SHALL BE CONCEALED AND APPROPRIATE TO THE SURFACE MOUNTING MATERIAL.ONLY SIMPLE HAND TOOLS SHALL BE REQUIRED FOR ASSEMBLY. Z.7 ENGINEERING. DESIGN OF CONNECTIONS AND MATERIALS USED SHALL BE SUCH AS TO ADHERE TO S'T'RUCTURAL REQUIREMENTS OF MAJOR BUILDING CODES. DRAWINGS AND REPRESENTATIVE ENGINEERING SHALL BE AVAILABLE FROM THE MANUFACTURER FOR THE PURPOSE OF PERMITS OR ARCHITECTURAL REVIEW. PART 3 EXECVTIOty 3.1 PREFABRICATION.ALL COMPONENT PARTS SHALL BE PRE-ASSEMBLED TO THE FULLEST EXTENT POSSIBLE,TO PRECLUDE ANY ON-SITE ARILLINQ.G 1TTING,FILL- ING,NAILING OR SANDING.ALL PREFABRICATION FASTENERS SHALL BE HIDDEN FROM VIEW OR CHANNELED AND STRIPPED WITH MATCHING $ �4 i BLE. 3.2 INSTALLATION. lUE GAzEso KIT SHALL BE SUPPLIED WITH ALL NECESSARY HARDWARE, SHOP DRAWINGS AND CONtPLETE INS' R EFFICIENT oN-sm AsSEmBLY.AVERAGE ASSEMBLY TIME ON A PREPARED FOUNDATION SHALL NOT EXCEED I S MAN-HOURS � � .' xv4 HILA. CEDAR .� PRODUCTS P0.8ox 389 - Elvvrsom PA 19,520 Greater! by: Andrea:Beringer Date:Jure 2013 � F