Loading...
HomeMy WebLinkAbout38319-Z Town of Southold Annex 8/26/2014 4& P.O. Box 1179 40 : 54375 Main Road 41F Southold, New York 11971 CERTIFICATE OF OCCUPANCY No: 37116 Date: 8/26/2014 THIS CERTIFIES that the building RESIDENTIAL ALTERATION Location of Property: 1580 N Bayview Rd, Southold, SCTM #: 473889 Sec/Block/Lot: 70.-12-34 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this officed dated 11/28/2011 pursuant to which Building Permit No. 38319 dated 9/13/2013 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: EXISTING ATTACHED GARAGE ALTERED TO LIVING SPACE IN AN EXISTING SINGLE FAMILY DWELLING AS APPLIED FOR The certificate is issued to Carbone,Michael&Carbone, Ellen (OWNER) of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 38319 08-21-2014 PLUMBERS CERTIFICATION DATED am_ u oriz -"ced Signature TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE CA • { SOUTHOLD, NY f01 BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit #: 38319 Date: 9/13/2013 Permission is hereby granted to: Carbone, Michael & Carbone, Ellen PO BOX 1164 -- - - Southold, NY 11971 To: CONVERT EXISTING ATTATCHED GARAGE TO DEN AS APPLIED FOR. REPLACES EXPIRED B.P. # 36852 At premises located at: 1580 N Bayview Rd, Southold SCTM # 473889 Sec/Block/Lot# 70.-12-34 Pursuant to application dated 11/28/2011 and approved by the Building Inspector. To expire on 3/13/2015. Fees: ALTERATION OF ACCESSORY BUILDINGS $390.00 Total: $390.00 �l ya• � Building Inspector og�FFoc.rco. TOWN OF SOUTHOLD o BUILDING DEPARTMENT TOWN CLERK'S OFFICE =, • SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit #: 36852 Date: 12/5/2011 Permission is hereby granted to: Carbone, Michael & Carbone, Ellen PO BOX 1164 Southold, NY 11971 To: convert existing attached garage to den as applied for At premises located at: 1580N Bayview Rd, Southold SCTM # 473889 Sec/Block/Lot# 70.-12-34 Pursuant to application dated 11/28/2011 and approved by the Building Inspector. To expire on 6/5/2013. Fees: SINGLE FAMILY DWELLING - ADDITION OR ALTERATION $390.00 CO -ALTERATION TO DWELLING $50.00 Total: $440.00 Building Inspector Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings,property lines,streets,and unusual natural or topographic features. 2. Final Approval from Health Dept.of water supply and sewerage-disposal(S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1%lead. 5. Commercial building,industrial building,multiple residences and similar buildings and installations,a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings(prior to April 9, 1957)non-conforming uses,or buildings and"pre-existing"land uses: 1. Accurate survey of property showing all property lines,streets,building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$25.00,Additions to dwelling$25.00,Alterations to dwelling$25.00, Swimming pool$25.00,Accessory building$25.00,Additions to accessory building$25.00, Businesses$50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy-$.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy-Residential $15.00,Commercial$15.00 Date. �� New Construction: Old or Pre-existing Building: -/ (check one) Location of Property: �� C� lu, 2)P' v 1c_:W EDL , LV ,)�- tv. House No. Street Hamlet Owner or Owners of Property: PLUG �(, �, i✓LL(:ti CP E E-)n, \, E Suffolk County Tax Map No 1000, Section C_j Block C Lot Subdivision Filed Map. Lot: Permit No. Date of Permit. Applicant: Health Dept. Approval: Underwriters Approval: Planning Board Approval: Request for: Temporary Certificate Final Certificate: (check one) Fee Submitted:$ j Applicant ignature Jt� x2 1 �pF SOU)" % Town Hall Annex �, Telephone(631)765-1802 54375 Main Road Fax (631)765-9502 P.O.Box 1 179 G 4 roger.riche rt(D_town.southold.ny.us Southold,NY 11971-0959 Q COUNTY,fkl���}, BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION Issued To: Michael Carbone Address: 1580 N Bayview Rd City: Southold St: NY Zip: 11971 Building Permit#: 38319 Section: 70 Block: 12 Lot: 34 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: Jim Shaw Electric License No: 33381-me SITE DETAILS Office Use Only Residential X Indoor X Basement Service Only Commerical Outdoor X 1st Floor X Pool New Renovation X 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt 11 Ceiling Fixtures 3 HID Fixtures Service 3 ph Hot Water GFCI Recpt 1 Wall Fixtures 1 Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Fluorescent Fixture Pumps Transformer Appliances Dryer Recpt Emergency Fixtures Time Clocks 11 Disconnect Switches 9 Twist Lock rl Exit Fixtures TVSS Other Equipment: convert garage to living space, 1-combination smoke/co detector Notes: Inspector Signature: , � : ; .. Date: Aug 21 2014 81-Cert Electrical Compliance Form.xls pf SOUIyOIo Ooum TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ) FOUNDATION 1ST [ ] ROUGH PLEIG. [ ] F NDATION 2ND [ ] INSULATION [ FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ) ELECTRICAL (ROUGH) [ ) ELECTRICAL (FINAL) REMARKS: ok. DATE 1-X/3LX INSPECTOR SOUlyOlo TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] R UGH PLBG. [ ] FOUNDATION 2ND [ INSULATION [ ] FRAMING / STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ FIRE RESISTANT PENETRATION [ ] ELECTRICAL (RQIUGH) [ ] ELECTRICAL (FINAL) REMARKS: J DATE INSPECTOR pf SOU-749 cou 1 TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PL13G. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING / STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION ] E ECTRICAL (ROUGH) ( ] ELECTRICAL (FINAL) REMARKS: DATE Z z f INSPECTOR ' couo, TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION IST [ ] ROUG PLUMBING [ ] FOUNDATION 2ND [ ] 1 LATION [ ] FRAMING / STRAPPING [ FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] CAULKING REMARKS: a � DATE INSPECTOR �� OF SOUTyolo Ulm,N TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 S INSPECTION [ ] FOUNDATION 1 ST [ ] ROUGH PLUMBING [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING / STRAPPING [ ] FINAL [ ] FIREPLACE A CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) 1'�el ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] CAULKING REMARKS: DATE �'f INSPECTO t��" FIELD IN ON REPORT DATE COMMENTS FOUNDATION(1ST) s � FOUNDATION (2ND) � z ROUGH FRAMING& t� PLUMBING t j y C INSULATION PER N.Y. H STATE ENERGY CODE y .. FINAL ADDITIONAL COMMENTS 41 Goq /Z j rn �" C TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD,NY 11971 4 sets of Building Plans TEL: (631)765-1802 Planning Board approval FAX: (631)765-9502 Suryey SoutholdTown.NorthFork.net PERMIT NO. � Check Septic Form N.Y.S.D.E.C. Trustees Flood Permit Examined 20 Storm-Water Assessment Form �D) L 'b LNOV ntact: Approved � 20� OU Marl to: Disapproved a/c 011K. U 0 o L7Phone: '��+2-4- Expiratiion (� 20 jOLD Building Inspector APPLICATION FOR BUILDING PERMIT Date 20 INSTRUCTIONS a.This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans,accurate plot plan to scale.Fee according to schedule. b.Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas,and waterways. c.The work covered by this application may not be commenced before issuance of Building Permit. d.Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant.Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f.Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date.If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize,in writing,the extension of the permit for an addition six months.Thereafter,a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk County,New York,and other applicable Laws,Ordinances or Regulations,for the construction of buildings,additions,or alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code,housing code,and regulations,and to admit authorized inspectors on premises and in building for necessary inspections. (Signature of applicant or name,if a corporation) (Mailing address of applicant) State whether applicant is owner, lessee,agent,architect,engineer, general contractor, electrician,plumber or builder A0644 t Name of owner of premisesiGEf F� �C LE�C1plU� As on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer (Name and title of corporate officer) Builders License No. Plumbers License No. Electricians License No. Other Trade's License No. 1. Location of land on which proposed work will be done: lD Al I3MSr VIII I -,e®.AD Q�rn"o House Number Street Hamlet County Tax Map No. 1000 Section D Block Lot Subdivision Filed Map No. Lot 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy �ESII1V 77C _ b. Intended use and occupancy / 3. Nature of work(check which applicable):New Building Addition Alteration V/ Repair Removal Demolition Other Work _ (Description) 4. Estimated Cost 000 Fee 440. _ (To be paid on filing this application) 5. If dwelling,number of dwelling units Number of dwelling units on each floor If garage, number of cars 6. If business,commercial or mixed occupancy, specify nature and extent of each type of use. _ 7. Dimensions of existing structures, if any: Front gl, jf Rear 1!5�/. 5( Depth ✓_� _ Height 4-1321 Number of Stories Dimensions of same structure with alterations or additions: Front Rear _ Depth Height Number of Stories 8. Dimensions of entire new construction: Front Rear Depth _ Height Number of Stories 9. Size of lot:Front 120 r Rear / .. � Depth gid( 10. Date of Purchase of Former Owner A4 t3, 1 5l`?K l 11.Zone or use district in which premises are situated 1�2 _ e—'O 12.Does proposed construction violate any zoning law,ordinance or regulation?YES NO V 13. Will lot be re-graded?YES NO /Will excess fill be removed from premises?YES NO__j&A 14.Names of Owner of premises �• �''�dG2 Address R%8 � Phone No. 90.2?3-!� Name of ArchitectAddress PPhone No 4,31 4.7?-d' Name of Contractor Address Phone No. _ 15 a.Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES ✓NO * IF YES, SOUTHOLD TOWN TRUSTEES&D.E.C. PERMITS,MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland?* YES ,,/ NO * IF YES, D.E.C.PERMITS MAY BE REQUIRED. 16. Provide survey,to scale,with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below,must provide topographical data on survey. 18.Are there any covenants and restrictions with respect to this property?* YES NO ✓ * IF YES,PROVIDE A COPY. STATE OF NEW YORK) SS: COUNTY OF hp"el LLZiglt-21ialf being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)He is the A lkC (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief;and that the work will be performed in the manner set forth in the application filed therewith. Sworn to before me this *iwhjr,2�day of A./�2V&U&r 20_&��``Notary Public of Applicant LAUREN is SI'ANDISi l Notary Public,State of New York No.01ST616400a Qualified in Suffolk County Commission F-Vires April 9,2 1 40) Town of Southold Erosion, Sedimentation A Storm-Water Run-off ASSESSMENT FORM PROPERTY LOCATION: S c Tx fitTHE FOLLOWDIS ACTIONS MAY REQUIRE THE SU N OF A �1c7f� STORM-WATE&GRADING,DRAINAGE Atha ER03ION COKMOL PUN CERTIFIED BY A DESIGN PROFESSIONAL RSI THE STATE OF NEw YQItlL SCOPE OF WORK - PROPOSED CONSTRUCTION ITj:M# I WORK ASSESSMENT Yes No a. What N the Total Aree of the Project Parcels? �')�j Inchhde Total Area of all Parcels located willim Y L._ j 41 this Project Retain Al Stam-Water Run-Off ( Me Scope of Work for Proposed Co�struction) Generated by a TWO(2')Inch Rainfall on Site? ZEI(SF.JA—) (ThisItern wit include all run-off created by site b. What is the Total Area of Land Clearing clearing and/or construction activities as wed as all and/or Ground Disturbance for the proposed Jr-'�/_ Ske IntproverrerNs and the permanent creation of ODmStrtJCtiOFn aCtYlty? (SF f Aoea) bripervious surfaces.) PROVIDE BRIEF PROJECT DESCRIPIYON tProa>ha Aa 0aonal Paces a Maadamq 2 Does the Site Plan arhd/or Survey Snow m Proposed Drainage Sbuciures Indicating Size&Location?This Item shad include all Proposed Grade Charges and Slopes Corttrdtrng Surface Water Flow. 3 Does the Site Plan and/or Survey describe the erosion ,/ L lC and sedirient control practices that will be used tom V control site erosion and storwater disch erges. This — a item must be maintained throughout the Entire Construction Period. 4 Will this Project Require any Land FMing,Gradro orear Excavation where there is a Change to the Natural / G� Existing Grade Involving more than 200 Cubic Yards v` of Material within any Parcel? 5 WIN this Application Require Land Disturbing Activities Encompassing an Area in Excess of Five Thousand (5,000 S.F.)Square Feat of Ground Surface? El — 6 Is there a Natural Water Course Running through the / Site? Is this Prof ed within the Trustees Oftlictwn —v General DEC SWPPP ReguMemarb: or within One Hundred(1 MY)feet of a Wetand or Submission of a SWPP is required for at Construction aciivdies inwMV sol Beach? disNubances of one(1)or more acres: k dudbV dlskmbences of less then Dna erre'hat Will there be Site are part of a tenger common plan that wit dt mately disturb one or more anon d land; 7 pBP aration on E'°�Grade Slopes Including Construction ac�vruea Wwdvtng soil�thrbm>�of less than one(1 whish Exceed 100')FReo Hoo tient of DVerticalsrRise to El the DEC has determined that a SPDES permit a required for storm water discharges. One Hundred{100')of Horizorhtal Disfarnce? (SWPPP s Shoff meat the trtnxhnan Regan of the 3PDE3 Ganarer Permit g Will Driveways,Parking Areas or other Impervious for storm water Discharges from ceMStrucaon acWffy-Permit No.GP4)40. t.) Surfaces be Sloped to Direct Stomp-Water Rix►-off 1.The SWPPP shat be prepared prior to the Submittal of the Not.The NOI shall be into and/or in the direction of a Town right-of-wart submitted to the Department prior to the commencement of construbm activity. j.. 2 The SWPPP shat describe the erosion and sediment control practices and where Q Wali this Prujnet Require the Placement of Materiel, required,postconstrumon storm water menegament practices that will be used andror Removal of Vegetation and/or the Construction of an i. Y constructed to reduce the pollutants in storm water discharges and to ascus Item Within the Town Ri ' compliance with the terms arse eonMons of this permit.M adMkw%the SWPPP shall Right-0 Way or Road Shoulder — — i Area?t maam vkw rwT trrara.tlme kmsulwbn of 0rlaewsy Apewa) identify potential sources at pollution which may reasonably be expected to atbri the i gu"of storm water discharges NOTE: of Any Answer to Question one through Nine Is Answered with a check Mark ! 3.AN SWPPP9 that require the post-wnsbuction storm water management practice In a Back and On construction site diarahsap is para sank SAM SR&I Acre it awe. componer t shall be prepared by a quet0ed Design Professional tfoensed in New York a Sbsnmallrater.Cbadioy,Drebaga&Erosion Control Plan is Required by dwTown of that is knovdedgoable in the principles and practices of Storm Water Manage enL Southold and Mex be&dwhkbd fer Review Prior to issuance of Any Be0dla0 Permit. i (NOTE: A Check Wok(J)ardor Amar foreadm Oueeion is Regkdffid for a anpiehe A01 ) i 1 STATE OF NEW YORK, c� COUNTY OF. �k. .............SS That T,. .. k� ..'�lkG4iL.� i 11_............_....being duly sworn,deposes and says that he/she is the applicant for Perrot, I (Name of indtviduaf slg[mhg Docunhekd) And that he/she is the ......��t' �t t: rL...... . (gwriei;Caiivei�oi:Ag—e' Cuejwiateoii6'w**,e**w' ....... Owner and/or representative of the Owner or Owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his knowledge and belief;and that the work will be performed in the manner set forth in the application filed heretri i Sworn to before me this; ? v .................................... dayofl f ......,20..1 Notary Public. .......... ......... ........... .. ...................................................... t (Stgrh-- , ornpvica+) FORM - 06110LAUKLM SIAMISM Notary Public,State of New YOfN No.01ST6164008 Qualified in Suffolk County Commission Expires April 9,20 _ 1 4��pF SO�jyo � 1p Town Hall Annex - -� 54375 Main Road c� �� ��' (61)7¢5g5(} P.O.Box 1179 G Q r0 er Yi Southold,NY 11971-0959 BUILDING DEPARTMENT TOWN OF SOUTHOLD � 1 APPLICATION FOR ELECTRICAL INSPECTION REQUESTED BY: Date: Company Name: Z /C� 3 Name: License No.: 33 3l yra Address: A"I 4W Phone No.: JOBSITE INFORMATION: (*Indicates required information) *Name: , k,� CAA�,J *Address: *Cross Street: � *Phone No.: Permit No.: b�' C' _ Tax-Map District: 1000 Section: Block: Lot: - *BRIEF DESCRIPTION OF WORK(Please Print Clearly) i G,A�/1 Pzt LA f AST v,✓/-v I (Please Circle All That Apply) *Is job ready for inspection: (::YjE )NO LRoughln Final *Do you need a Temp Certificate: YES NO I Temp Information (If needed) `Service Size: 1 Phase 3Phase 100 150 200 300 350 400 Other *New Service: Re-connect Underground Number of Meters Change of Service Overhead ' Additional Information: PAYMENT DUE WITH APPLICATION J i f 82-Request for Inspection Form ti y � o Town Hall Annex Telephone(631)765-1802 54375 Main Road Fax (63 1) 765-9502 P.O. Box 1179 O • O Southold,NY 11971-0959 COU August August 11, 2014 BUILDING DEPARTMENT TOWN OF SOUTHOLD Michael & Ellen Carbone PO Box 1164 Southold NY 11971 Re: 1580 N Bayview Rd, Southold TO WHOM IT MAY CONCERN.- The ONCERN:The Following Items(if Checked) Are Needed To Complete Your Certificate of Occupancy: Application for Certificate of Occupancy. (Enclosed) n lectrical Underwriters Certificate. A fee of$50.00. Final Health Department Approval. Plumbers Solder Certificate. (All permits involving plumbing after 4/1/84) Trustees Certificate of Compliance. (Town Trustees#765-1892) Final Planning Board Approval. (Planning #765-1938) Final Fire Inspection from Fire Marshall. Final Landmark Preservation approval. Final inspection by Building Dept. Final Storm Water Runoff Approval from Town Engineer BUILDING PERMIT — 38319 - Alteration Generated by REScheck-Web Software Compliance Certificate 71 w i I Project Title: THE CARBONE RESIDENCE Energy Code: 2010 New York Energy Conservation Construction Code Location: Suffolk County,New York BLDG DEPT. Construction Type: Single Family TOWN Y) Ti10•.D Building Orientation: Bldg.orientation unspecified Glazing Area Percentage: 12% Heating Degree Days: 5750 Climate Zone: 4 Construction Site: Owner/Agent: Designer/Contractor: 1580 N.BAYVIEW ROAD FRANK UELLENDAHL SOUTHOLD,New York 11971 ARCHITECT ,Compliance: Compliance:3.6%Better Than Code Maximum UA:139 Your UA:134 The%Better or Worse Than Code index reflects how dose to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. AssemblyGross Cavity Cont. Glazing UA or or D•• Perimeter U-Factor Ceiling:Cathedral 704 30.0 0.0 24 Wall:Wood Frame,16in.o.c. 207 13.0 0.0 13 Orientation:Front Window:Wood Frame,2 Pane w/Low-E 17 0.280 5 SHGC:0.00 Orientation:Front Window:Wood Frame,2 Pane w/Low-E 18 0.300 5 SHGC:0.00 Orientation:Front Door:Solid 17 0.260 4 Orientation:Front Wall:Wood Frame, 16in.D.C. 195 17.0 0.0 11 Orientation:Right Side Window:Wood Frame,2 Pane w/Low-E 26 0.380 10 SHGC:0.00 Orientation:Right Side Wall:Wood Frame,16in.D.C. 207 13.0 0.0 14 Orientation:Back Window:Wood Frame,Single Pane 13 0.380 5 SHGC:0.00 Orientation:Back Door:Glass 20 0.310 6 SHGC:0.00 Orientation:Back Wall:Wood Frame,16in.o.c. 195 17.0 0.0 12 Orientation:Left Side Floor:All-Wood Joist/Truss Over Uncond.Space 475 17.0 0.0 25 Compliance Statement: The i�<ii n described here is consistent with the building plans,specifications,and other calculations bmitted with I roposed building has been designed to meet the 2010 New York Energy Conservation Construction a requir f Sit comply with the mandatory requirements listed in the REScheck Inspection Checklist. Project Title:THE CAR Report date: 12/05/11 Data filename: Page 1 of 6 v Generated by REScheck-Web Software Inspection Checklist Ceilings: ❑ Ceiling:Cathedral,R-30.0 cavity insulation Comments: Above-Grade Walls: ❑ Wall:Wood Frame,16in.o.c.,R-13.0 cavity insulation Comments: ❑ Wall:Wood Frame, 16in.o.c.,R-17.0 cavity insulation Comments: ❑ Wall:Wood Frame,16in.o.c.,R-13.0 cavity insulation Comments: ❑ Wall:Wood Frame,16in.o.c.,R-17.0 cavity insulation Comments: Windows: ❑ Window:Wood Frame,2 Pane w/Low-E,U-factor:0.280 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ Window:Wood Frame,2 Pane w/Low-E,U-factor:0.300 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ Window:Wood Frame,2 Pane w/Low-E,U-factor:0.380 For windows without labeled U-factors,describe features: Vanes Frame Type Thermal Break? Yes No Comments: ❑ Window:Wood Frame,Single Pane,U-factor:0.380 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: Doors: ❑ Door:Solid,U-factor:0.260 Comments: This door is exempt from the U-factor requirement. ❑ Door:Glass,U-factor:0.310 Comments: Floors: ❑ Floor:All-Wood Joist/Truss Over Uncond.Space,R-17.0 cavity insulation Comments: Floor insulation is installed in permanent contact with the underside of the subfloor decking. Air Leakage: ❑ Joints(including rim joist junctions),attic access openings,penetrations,and all other such openings in the building envelope that are sources of air leakage are sealed with caulk,gasketed,weatherstripped or otherwise sealed with an air barrier material,suitable film or solid material. Project Title:THE CARBONE RESIDENCE Report date: 12/05/11 Data filename: Page 2 of 5 Air barrier and sealing exists on common walls between dwelling units,on exterior walls behind tubs/showers,and in openings between window/doorjambs and framing. ❑ Recessed lights in the building thermal envelope are 1)type IC rated and ASTM E283 labeled and 2)sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. Access doors separating conditioned from unconditioned space are weather-stripped and insulated(without insulation compression or damage)to at least the level of insulation on the surrounding surfaces.Where loose fill insulation exists,a baffle or retainer is installed to maintain insulation application. Wood-buming fireplaces have gasketed doors and outdoor combustion air. Lj Automatic or gravity dampers are installed on all outdoor air intakes and exhausts. Air Sealing and Insulation: Lj Building envelope air tightness and insulation installation complies by either 1)a post rough-in blower door test result of less than 7 ACH at 50 pascals OR 2)the following items have been satisfied: (a)Air barriers and thermal barrier:Installed on outside of air-permeable insulation and breaks or joints in the air barrier are filled or repaired. (b)Ceiling/attic:Air barrier in any dropped ceiling/soffit is substantially aligned with insulation and any gaps are sealed. (c)Above-grade walls:Insulation is installed in substantial contact and continuous alignment with the building envelope air barrier. (d)Floors:Air barrier is installed at any exposed edge of insulation. (e)Plumbing and wiring:Insulation is placed between outside and pipes.Batt insulation is cut to fit around wiring and plumbing,or sprayed/blown insulation extends behind piping and wiring. (f) Corners,headers,narrow framing cavities,and rim joists are insulated. (9)Shower/tub on exterior wall:Insulation exists between showers/tubs and exterior wall. Sunrooms: Sunrooms that are thermally isolated from the building envelope have a maximum fenestration U-factor of 0.50 and the maximum skylight U-factor of 0.75.New windows and doors separating the sunroom from conditioned space meet the building thermal envelope requirements. Materials Identification and Installation: Materials and equipment are installed in accordance with the manufacturer's installation instructions. Insulation is installed in substantial contact with the surface being insulated and in a manner that achieves the rated R-value. ❑ Materials and equipment are identified so that compliance can be determined. L1 Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment have been provided. L1 Insulation R-values and glazing U-factors are clearly marked on the building plans or specifications. Duct Insulation: Lj Supply ducts in attics are insulated to a minimum of R-8.All other ducts in unconditioned spaces or outside the building envelope are insulated to at least R-6. Duct Construction and Testing: Lj Building framing cavities are not used as supply ducts. Lj All joints and seams of air ducts,air handlers,filter boxes,and building cavities used as return ducts are substantially airtight by means of tapes,mastics,liquid sealants,gasketing or other approved closure systems.Tapes,mastics,and fasteners are rated UL 181A or UL 181 B and are labeled according to the duct construction.Metal duct connections with equipment and/or fittings are mechanically fastened.Crimp joints for round metal ducts have a contact lap of at least 1 1/2 inches and are fastened with a minimum of three equally spaced sheet-metal screws. Exceptions: Joint and seams covered with spray polyurethane foam. Where a partially inaccessible duct connection exists,mechanical fasteners can be equally spaced on the exposed portion of the joint so as to prevent a hinge effect. Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in.w.g.(500 Pa). Duct tightness test has been performed and meets one of the following test criteria: (1)Postconstruction leakage to outdoors test:Less than or equal to 38.0 cfm(8 cfm per 100 ft2 of conditioned floor area). (2)Postconstruction total leakage test(including air handler enclosure):Less than or equal to 57.0 cfm(12 cfm per 100 ft2 of conditioned floor area). (3)Rough-in total leakage test with air handler installed:Less than or equal to 28.5 cfm(6 cfm per 100 ft2 of conditioned floor area). (4)Rough-in total leakage test without air handler installed:Less than or equal to 19.0 cfm(4 cfm per 100 ft2 of conditioned floor area). Temperature Controls: Project Title:THE CARBONE RESIDENCE Report date: 12/05/11 Data filename: Page 3 of 5 Where the primary heating system is a forced air-fumace,at least one programmable thermostat is installed to control the primary heating system and has set-points initialized at 70 degree F for the heating cycle and 78 degree F for the cooling cycle. Lj Heat pumps having supplementary electric-resistance heat have controls that prevent supplemental heat operation when the compressor can meet the heating load. Heating and Cooling Equipment Sizing: Lj Additional requirements for equipment sizing are included by an inspection for compliance with the International Residential Code. F1 For systems serving multiple dwelling units documentation has been submitted demonstrating compliance with 2009 IECC Commercial Building Mechanical and/or Service Water Heating(Sections 503 and 504). Circulating Service Hot Water Systems: ❑ Circulating service hot water pipes are insulated to R-2. ❑ Circulating service hot water systems include an automatic or accessible manual switch to tum off the circulating pump when the system is not in use. Heating and Cooling Piping Insulation: Lj HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F are insulated to R-3. Swimming Pools: Lj Heated swimming pools have an on/off heater switch. Lj Pool heaters operating on natural gas or LPG have an electronic pilot light. Lj Timer switches on pool heaters and pumps are present. Exceptions: Where public health standards require continuous pump operation. Where pumps operate within solar-and/or waste-heat-recovery systems. Heated swimming pools have a cover on or at the water surface.For pools heated over 90 degrees F(32 degrees C)the cover has a minimum insulation value of R-12. Exceptions: Covers are not required when 60%of the heating energy is from site-recovered energy or solar energy source. Lighting Requirements: L] A minimum of 50 percent of the lamps in permanently installed lighting fixtures can be categorized as one of the following: (a)Compact fluorescent (b)T-8 or smaller diameter linear fluorescent (c)40 lumens per watt for lamp wattage—15 (d)50 lumens per watt for lamp wattage>15 and—40 (e)60 lumens per watt for lamp wattage>40 Other Requirements: Snow-and ice-melting systems with energy supplied from the service to a building shall include automatic controls capable of shutting off the system when a)the pavement temperature is above 50 degrees F,b)no precipitation is falling,and c)the outdoor temperature is above 40 degrees F(a manual shutoff control is also permitted to satisfy requirement's'). Certificate: A permanent certificate is provided on or in the electrical distribution panel listing the predominant insulation R-values;window U-factors;type and efficiency of space-conditioning and water heating equipment.The certificate does not cover or obstruct the visibility of the circuit directory label,service disconnect label or other required labels. NOTES TO FIELD:(Building Department Use Only) Project Title:THE CARBONE RESIDENCE Report date: 12/05/11 Data filename: Page 4 of 5 f Project Title:THE CARBONE RESIDENCE Report date: 12/05/11 Data filename: Page 5 of 5 2010 New York Energy Conservation Construction Code Certificatc. Insulation Rating R-Value Ceiling i Roof 30.00 Wail 17.00 Floor!Foundation 17.00 Ductwork(unconditioned spaces): 'Glass;&Door Rating U-Factor SHGC Window 0.38 Door 0.31 NA �Heatlng&Cooling Equipment Efficiency Heating System: Cooling System: Water Heater: Name: Date: Comments: 2—' Generated by REScheck-Web Software Compliance Certificate Project CARBONE RESIDENCE D E C E U E Energy Code: 2010 New York Energy Conservation Location: Suffolk County, New York JAN 13 2014 Construction Type: Single-family Project Type: Alteration Climate Zone: 4 (5750 HDD) BLDG.SOUTH tOhN Of SOIJTHOLD Permit Date: Permit Number: Construction Site: Owner/Agent: Designer/Contractor: (3 AYv ii=�,0 Z'D Compliance: Compliance: 0.0%Better Than Code Maximum UA: 155 Your UA: 155 The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Envelope Assemblies Gross Area Cavity Cont. Glazing Assembly or R-Value R-Value or Door UA Perimeter U-Factor Ceiling: Cathedral 704 22.0 0.0 0.046 31 Skylight: Metal Frame, 2 Pane w/Low-E 28 0.410 11 Wall: Wood Frame, 16in,o.c. 804 15.0 0.0 0.077 53 Window: Wood Frame, 2 Pane w/Low-E 17 0.280 5 Window:Wood Frame, 2 Pane w/Low-E 18 0.300 5 Window: Wood Frame, 2 Pane w/Low-E 26 0.380 10 Window:Wood Frame, Double Pane 13 0.380 5 Door: Solid 17 0.260 4 Door: Glass 20 0.310 6 Floor:All-Wood Joist/Truss Over Uncond.Space 475 17.0 0.0 0.052 25 Compliance Statement: The proposed building design described her i c sistent with the building plans, specifications, and other calculations submitted with the permit application.The proposed buil i g as been designed to meet the 2010 New York Energy Conservation Construction Code requirements in REScheck Version 5 n 't omply with the mandatory requirements listed in the REScheck Inspection Checklist. f K__�Lc [A t-t � Name-Title Slgrta�u Date tp �. H Project Title: CARBONE RESIDENCE Report date: 12/26/13 Data filename: Pagel of 7 REScheck Software Version 5.5.0 Inspection Checklist Energy Code: 2010 New York Energy Conservation Construction Code Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section Plans Verified Field Verified # Pre-Inspection/Plan Review Value Value Complies? Comments/Assumptions & Req.ID 103.2 Construction drawings and ❑Complies [PR1]1 documentation sufficiently ❑Does Not demonstrates energy code compliance for the building ❑Not Observable envelope. ❑Not Applicable 103.2, Construction drawings and ❑Complies 403.7 documentation sufficiently ❑Does Not [PR3]1 demonstrates energy code compliance for lighting and ❑Not Observable mechanical systems.Systems ❑Not Applicable serving multiple dwelling units must demonstrate compliance with the commercial code. 403.6 Heating and cooling equipment is Heating: Heating: ❑Complies [PR2]2 sized per ACCA Manual S based Btu/hr Btu/hr ❑Does Not on loads per ACCA Manual J or Cooling: Cooling: ❑Not Observable other approved methods. Btu/hr Btu/hr ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: CARBONE RESIDENCE Report date: 12/26/13 Data filename: Page 2 of 7 2010 New York Foundation Inspection Complies? Comments/Assumptions Energy 303.2.1 Exposed foundation insulation ❑Complies [FOIJ]2 protection. ❑Does Not ❑Not Observable ❑Not Applicable 403.8 Snow melt controls. ❑Complies [FO12]2 ❑Does Not ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: CARBONE RESIDENCE Report date: 1226/13 Data filename: Page 3 of 7 Section Plans Verified Field Verified # Framing/Rough-In Inspection Value Value Complies? Comments/Assumptions & Req.ID 402.4.4 Fenestration that is not site built ❑Complies [FR20]1 is listed and labeled as meeting ❑Does Not AAMA/WDMA/CSA 101/I.S.2/A440 or has infiltration rates per NFRC [:]Not Observable 400 that do not exceed code ❑Not Applicable limits. 402.4.5 IC-rated recessed lighting fixtures ❑Complies [FR16]2 sealed at housing/interior finish ❑Does Not and labeled to indicate&It;= 2.0 ❑Not Observable cfm leakage at 75 Pa. ❑Not Applicable 403.2.1 Supply ducts in attics are R- R- ❑Complies [FR12]1 insulated to R-8.All other ducts R- R- ❑Does Not in unconditioned spaces or ❑Not Observable outside the building envelope are insulated to R-6. Not applicable if ❑Not Applicable all systems are ductless. 403.2.2 All joints and seams of air ducts, ❑Complies [FR13]1 air handlers,filter boxes,and ❑Does Not building cavities used as return ❑Not Observable ducts are sealed. ❑Not Applicable 403.2.3 Building cavities are not used as ❑Complies [FR15]3 ducts or plenums. ❑Does Not ❑Not Observable ❑Not Applicable 403.3 HVAC piping conveying fluids R- R- ❑Complies [FR17]2 above 105 QF or chilled fluids ❑Does Not below 55 QF are insulated to R-3. ❑Not Observable []Not Applicable 403.4 Circulating service hot water R- R- ❑Complies [FR18]2 pipes are insulated to R-2. ❑Does Not ❑Not Observable ❑Not Applicable 403.5 Automatic or gravity dampers are ❑Complies [FR19]2 installed on all outdoor air ❑Does Not intakes and exhausts. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: CARBONE RESIDENCE Report date: 12/26/13 Data filename: Page 4 of 7 2010 New York Insulation Inspection Complies? Comments/Assumptions Energy 303.1 All installed insulation labeled or ❑Complies [IN13]2 installed R-values provided. ❑Does Not ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: CARBONE RESIDENCE Report date: 12/26/13 Data filename: Page 5 of 7 Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID 402.4.2, Building envelope tightness ACH 50 = ACH 50 = ❑Complies 402.4.2.1 verified by blower door test result ❑Does Not [FI17]1 of&lt;7 ACH at 50 Pa.This requirement may instead be met []Not Observable via visual inspection, in which ❑Not Applicable case verification may need to occur during Insulation Inspection. 402.4.3 Wood-burning fireplaces have ❑Complies [FI8]2 gasketed doors and outdoor ❑Does Not combustion air. ❑Not Observable ❑Not Applicable 403.2.2 Duct tightness via post- cfm cfm ❑Complies [F14]1 construction with maximum ❑Does Not leakage of 8 cfm to outdoors,or 12 cfm across systems. For ❑Not Observable rough-in tests,verification may ❑Not Applicable need to occur during Framing Inspection, with maximum leakage of 6 cfm across systems and 4 cfm without air handler. 403.1.1 Programmable thermostats ❑Complies [FI9]2 installed on forced air furnaces. ❑Does Not ❑Not Observable ❑Not Applicable 403.1.2 Heat pump thermostat installed ❑Complies [FI10]2 on heat pumps. ❑Does Not ❑Not Observable ❑Not Applicable 403.4 Circulating service hot water ❑Complies [FI11]2 systems have automatic or ❑Does Not accessible manual controls. ❑Not Observable ❑Not Applicable 403.9.1 Readily accessible switch on ❑Complies [FI12]3 heaters for swimming pools. ❑Does Not ❑Not Observable ❑Not Applicable 403.9.2 Timer switches on pool heaters ❑Complies [FI19]3 and pumps are present. []Does Not ❑Not Observable ❑Not Applicable 403.9.3 Heated swimming pools have a ❑Complies [F120]3 cover.Covers on pools heated ❑Does Not over 90 4F are insulated to R-12. ❑Not Observable ❑Not Applicable 401.3 Compliance certificate posted. ❑Complies [FI7]2 ❑Does Not ❑Not Observable ❑Not Applicable 303.3 Manufacturer manuals for ❑Complies [FI18]3 mechanical and water heating ❑Does Not equipment have been provided. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: CARBONE RESIDENCE Report date: 12/26/13 Data filename: Page 6 of 7 2010 New York Energy Conservation Construction Code Energy Efficiency Certificate Insulation . Wall 15.00 Floor 17.00 Ceiling / Roof 22.00 Ductwork (unconditioned spaces): Door Rating LI-Factor SHGC Window 0.38 Door 0.31 Skylight 0.41 Cooling Heating System: Cooling System: Water Heater: Name: Date: Comments GENERAL NOTES DESIGN CRITERIA: AREA SUMMARY W GARAGE ZCONVERSION LOT AREA = ca.22,904 = 100.00% AND 1, ALL WORK MATERIAL AND EQUIPMENT SHALL BE IN GROUND SNOW LOAD - 45 PSF. EXIST'G BLDG. COVERAGE = Co. 3,379 SF = 14.75% O PROPOSED ACCORDANCE WITH THE NEW YORK STATE UNIFORM LIVING AREAS AND DECKS - 40 PSF. ADDED BLDG. COVERAGE = ca. 506 SF N m NEW GARAGE BUILDING CODE, AND THE NEW YORK STATE ENERGY TOTAL BLDG. COVERAGE = ca. 3,885 SF = 16.97% J SLEEPING AREA - 30 PSF. WCC CONSERVATION CODE, AND LOCAL AUTHORITIES. WIND SPEED - 120 MPH O MAX. ALLOW. COVERAGE = ca. 4,581 SF = 20.00% I Q 44 2. ALL CONCRETE SHALL BE STONE AGGREGATE WITH A SEISMIC DESIGN CATEGORY - B SOP MINIMUM 28 DAY STRENGTH OF 3000 PSI WEATHERING - SEVERE \Vn PROPOSED 2-CAR GARAGE 3. ALL LUMBER SHALL BE GRA E STAMPED DOUGLAS FIR- FROST LINE DEPTH - 36" P .�N = LARCH STRUCTURAL GRADE 2 OR BETTER. TERMITE - MODERATE TO HEAVY DECAY - SLIGHT ����� EXISTING STRUCTURE/6z9V QCSuc�i w RESIDENCE 4. PROVIDE DOUBLE HEADERS AND TRIMMERS AT ALL ICE SHIELD UNDERLAYMENT REQUIRED - YES /' STAIR AND FLOOR OPENINGS POSTS AND PARALLEL / PARTITIONS, EXCEPT AS NOTEb ON DRAWING. o EXISTING STRUCTURE SOUTHOLD, NY DESIGN IN ACCORDANCE WITH AMERICAN FORESTE:1 5. BRIDGING TO BE PROVIDED FOR ALL JOISTS AND PRODUCTS WOOD FRAME CONSTRUCTION MANUAL FLOOR BEAMS. SPACING NOT TO EXCEED 8.0 FT. FOR 1&2- FAMILY HOUSE - PRESCRIPTIVE DESIGN METHOD 1580 N. BAYVIEW RD9 SURVEY BY PECONIC SURVEYORS, 6. ALL DIMENSIONS AND GRADE CONDITIONS TO BEN P.C. � VERIFIED BY CONTRACTOR S) PRIOR TO START OF / r to DATED: MAY 19 2011 w z SEPTIC SYSTEM ��° CONSTRUCTION AND ORDERNG OF MATERIALS. THIS WINDBORNE / O s°� ARCHITECT FOUNDATION HAS BEEN DESIGNED FOR A SOIL / i• O Z BEARING CAPACITY OF TWO(2) TSF AND GRADES DEBRIS PROTECTION SCHEDULE Q-`� o FRANK UELLENDAHL LESS THAN 5%. CONTRACTOR SHALL VERIFY THAT 1` m 123 CENTRAL AVENUE THESE CONDITIONS ARE MET. ALL FILL BENEATH P.O.BOX 315 PRECUT WOOD STRUCTURAL PANELS WITH A THICKNESS PROPOSED GREENPORT, NY 11944 CONCRETE SLABS TO BE COMPACTED TO 95% GARAGE = TEL: 631-417 8624 RELATIVE DENSITY. OF MIN 7/16 INCH WITH 2-1/2 #6 WD SCREWS, 506 SF 7. ALL HEADERS 6.0 FT IN LENGTH AND OVER TO BE SPACING: 12 INCHES, ARE TO BE PROVIDED TO COVER MAX. 18' HIGH SUPPORTED BY DOUBLE UPRIGHTS, 9.0 FT AND OVER THE GLAZED OPENINGS OF THE PROPOSED GARAGE ADDITION "13' OWNERS BY TRIPLE UPRIGHTS. ALL HEADERS TO BE \ J MINIMUM OF 2-2X8 OR AS SHOWN ON DRAWING. MICHAEL & EARBONE 1580 N. BAYVELLEN LLEN CC ROAD 8. PROVIDE FIRESTOPPING AT ALL LEVEL WINDOW SCHEDULE FXT'G GARAGE �� `'g Cd Cd SOUTHOLD, NY 11971 PENETRATIONS o To BE CONVERTED TO \ 3 TEL: 917-273-6568 ro DEN RESIDENCE x _ 9. PROVIDE FLASHING AT ALL ROOF BREAKS, Z - CHIMNEYS SKYLIGHTS, EXTERIOR DOORS, WINDOWS PROPOSED WINDOWS ARE ANDERSEN PRODUCTS, 400 SERIES `' \ AND DECKS ETC.. WHITE EXTERIOR, INTERIOR: PRE-FINISHED WHITE, NO GRILLES 10. DO NOT SCALE DRAWINGS. GLASS TO BE HIGH PERFORMANCE LOW-E GLASS 11. DESIGN CONSULTANTS OR RECORD ARCHITECT- SCREENS TO BE PROVIDED FOR ALL WINDOWS AND DOORS ENGINEER ARE NOT RESPONSIBLE FOR THE WINDOW HARDWARE: CLASSIC SERIES, FINISH: WHITE FXr'c oEc�� `� - Y k] INSPECTION SUPERVISION OR ADMINISTRATION OF THIS CONSTRUCTION PRbJECT. FEDERAL STATE �� �� nif` AND LOCAL ZONING AND BUILDING CODE CbMPLIANCE N , SHALL BE THE RESPONSIBILITY OF THE Mark Size Description Quantity F -- CONTRACTOR. P Y 12. THIS DRAWING IS AN INSTRUMENT PREPARED TO A TW21042 EXT'G DH STORMWATCH 3T Kir TE5:l �.a -EF ORE ® ^^` FACILITATE CONSTRUCTION AND SHALL NOT BE B 2868 SOLID DOOR TO MUD ROOM 1 A CONSTRUED AS A CONTRACT BETWEEN BUILDER AND C FWH31611AR PATIO DOOR TO DECK 1 how 4 4f! '2r �l� OWNER. D CN15L&R CASEMENT 2 APPROVED AS NOTED 13. THIS STRUCTURE HAS BEEN DESIGNED IN E 11KuMB I1b ff i�1ARfbN 1 F s ACCORDANCE WITH THE NEW YORK STATE ENERGY r �Al� CONTENT BEFORE DATE �- 7• B.P. CONSERVATION CODE : ' 14, ENGINEER TO BE NOTIFIED IN WRITING OF ALL CLQ-77FICATEOF OCCUPANCY FEE: 2k"• BYoti CHANGES PRIOR TO AND DURING CONSTRUCTION, SOI.DEA IN WA =' NOTIFY BUILDING DEPARTMENT AT '�1 N LA 15. ELECTRICAL AND MECHANICAL COMPONENTS TO BE 765-1802 8 AM TO 4 PM FOR THE 48.31 DESIGNED AND SPECIFIED BY OTHERS. SUPPLYSYSTEMCANt. _ FOLLOWNGINSPECTIONS: IT CF"' ?F PROPOSED SITE PLAN EXCEED yt 0 OF 1% L_ 1. FOUNDATION-TWO REQUIRED 16. CONTRACTOR SHALL OBTAIN ALL PERMITS AND FOR POURED CONCRETE SCTM 1000-70-12-34 AND OWNER ,NECECE SSARY TO PROTECT THE ENGINEER ELECTRICAL 2. ROUGH.FRAMING,PLUMBING, �v �� OWN OF SOUTHOLD STRAPPING,ELECTRICAL 8 CAULKING SUFFOLK COUNTY NEW YORK =w DATE: 11/28/2011 au xz a F:y„ .y 3 SCALE: 1/32" = 1'-0" 17. DO NOT BACKFILL AGAINST FOUNDATION WALLS r4SPECTI � 3. INSULATION UNTIL FLOOR SYSTEM INSTALLATION IS COMPLETE. 4. FINAL-CONSTRUCTION 9 EL ECTR!C.AL 3 GARAGE CONVERSION TO RESIDENTIAL SPACE SITE PLAN MUST BE CC',IPLE L R Z DRAWING SCHEDULE 4LLCo"';STRUC 'ON luALI '�, :FT THF �o GENERAL NOTES REQUIREMENTS STATE OF ;� _)ES r .. BUILDING PERMIT APPLICATION z DESIGN CRITERIA 'ORK STATE. NOT RF`�°�ti� - � R 5 DWG. NAME A-1 SITE PLAN - DESIGN CRITERIA GENERAL NOTES JESIGN OR CONSTRUCTION ERRORS A-1 A-2 FLOOR PLAN g A-3 SECTION NOVEMBER 28, 2011 SCALE: 1 " = 30' e DWG. NO A-4 ELEVATIONS W GARAGE Z CONVERSION EXISTING AND DECK O PROPOSED NEW GARAGE U w 0 U I W J UP N RESIDENCE EXISTING DECK & SOUTHOLD, NY UP 1580 N. BAYVIEW RD 6'-8" STORMWATCH EXT'G TW21042 Z z ARCHITECT FRANK UELLENDAHL m 123 CENTRAL AVENUE TCTI L n a P.O.BOX 316 BREAKFAST ^^ � GREENPORT, NY 11944 MECH. R M. TEL: 631-477 8624 NOCK 61 SF o MEX1STING-56­®RqS ASDOWNERS N oMICHAEL & ELLEN CARBONE 1580 N. BAYVIEW ROAD SOUTHOLD, NY 11971 X N 3 TEL: 917-273-6568 - - - - - - - - - - - - - - — w f;- �� (2) 1.75X9.5" LVL COLLAR B M — ,�;�� ` E- 01 - (2) 2X10 HEADER r UP ! DEN r, t HW FLOOR I �* CATHEDRAL CEILING - TO MATCH EXT'G I 1 TILES - RADIANT HEAT r FIREPLACE N 410 SF Z `: r, 4- COATS COATS — — — _ (2) 1.75"X9.5" LVL COLLAR BEAM — 3'-2" 2'-101/2" M - —- - D — — — — — — — — — — — — — — — — REF — — . c 6'-2" X 2'-4" X 1'-4" DEEP -20 4 1/2" CONCRETE FOUNDATION UNDER �Q " FIREPLACE 3 o Z Mf a MUD RM. x� TILES a w o w 65 SF - � s Cn I j Q N JW N oo co Q CUT DOWN FOUNDATION cD cD WALL IN THIS AREA 2X4 STUD Z DATE: 11/28/2011 w SCALE: 1/4" = 1'-0" �z CN 151- AFC25 CN15R 3 Y = LEGEND6'-7 GONG. PAD 4'X2' ,'-8 1/2" 4'_D„ FLOOR PLAN 4„ 6 7 1/2" _ 4 1/2„ 6 0° 4" o z DWG. NAME NEW WALL _ __ _ _ o EXISTING WALL 1 ST FLOOR PLAN ®� DWG. NO A-2 DEMOLITION SCALE: 1/4" = 1'-0" ,EGARAGE Z CONVERSION AND O PROPOSED m NEW GARAGE J � O x I N o z w EXT'G 2X6 R.R. @ 16" O.C. RESIDENCE SOLIDLY FILLED WITH CLOSED CELL w SOUTHOLD, NY INSULATION (ICYNENE) ON BAFFLES (R-38) 1580 N. BAYVIEW RD FOR PROPER VENTING Z ARCHITECT FRANK UELLENDAHL J 123 CENTRAL AVENUE o P.O.BOX 316 GREENPORT, NY 11944 4 -� / TEL: 631-477 8624 f - DECORATIVE RAILING 10 OWNERS 1 (2) 1.75"X9.5" LUL COLLAR BEAM oMICHAEL & ELLEN CARBONE — WRAPPED IN 3/4 FIR 1580 N. W ROAD soTEL: 9LD, N7EXT G 2X4 STUDS 16 O.C. 73'6568 3 SOLIDLY FILLED WITH CLOSED CELL Y - - - INSULATION (ICYNENE) -R-21 EXTEND HIGH CEILING FOR PROPER HEAD ROOM 9" VENTED SOFFIT TO MATCH EXT'G ALL TRIMWORK TO MATCH EXT'G RESIDENCE o r REMOVE EXT'G STAIR DEN 3 EXT'G 2X4 STUDS @ 16" O.C. z 0 SOLIDLY FILLED WITH CLOSED CELL TILES-THIN SET ON 112' CEMENT BACKER 131 INSULATION (ICYNENE) FOR R-21 ON 112" PLYWOOD FOR RADIANT HEAT INS Ali. ON 1/2" PLY SUBFLOOR 1 " THICK R-5 RIGID INSULATION � DATE: 11/28/2011 SCALE: 3/8° = 1'-0" 4" R-20 RIGID INSULATION BETWEEN 2X6 F.J. @ 16 O.C. ON TRT'D SLEEPERS 6'-2" X 2'-4" X 1'-4" DEEP w SECTION N 2"-3" AIR SPACE CONCRETE FOUNDATION UNDER 6 MIL MEMBRANE ON EXT'G CONCRETE SLAB FIREPLACE CROSS SECTION A-A DWG. NAME - - - - — 23>8 _ SCALE: 1/4" = 1'-0° �� DWG. NO A-3 - _ - _ ®a GARAGE i Z CONVERSION AND O PROPOSED m NEW GARAGE J � X W D yZj U _N N RESIDENCE SOUTHOLD, NY 1580 N. BAYVIEW RD ARCHITECT FRANK UELLENDAHL 123 CENTRAL AVENUE o P.O.BOX 316 GREENPORT, NY 11944 ■ � TEL: 631-477 8624 OWNERS MICHAEL k ELLEN CARBONE 1580 N. BAYVIEW ROAD SOUTHOLD, NY 11971 3 TEL: 917-273-6568 Y Z !i 9j4L ` .. BACK ELEVATION SCALE: 3/16" = 1'-0" Jeri? o t:? tC w z o o � m o 0 � N O W ■ ■ O W DATE: 11/28/2011 SCALE: 3/16" = i'-0" 3 o ELEVATIONS Z DWG. NAME Ll - - g o� A-4 ®� DWG. NO FRONT ELEVATION SIDE ELEVATION SCALE: 3/16" = 1'-0" SCALE: 3/16" = 1'-0"