Loading...
HomeMy WebLinkAbout36831-Z XX u Town of Southold Annex 8/8/2014 P.O. Box 1179 54375 Main Road '✓ W Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 37080 Date: 8/8/2014 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 1110 E Cedar Point Dr, Southold, SCTM#: 473889 Sec/Block/Lot: 90.-2-20 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this officed dated 11/9/2011 pursuant to which Building Permit No. 36831 dated 11/22/2011 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: ROOF MOUNTED SOLAR PANELS TO A SINGLE FAMILY DWELLING AS APPLIED FOR The certificate is issued to Williams P J Rev Liv Trst (OWNER) of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 36831 02-13-2012 PLUMBERS CERTIFICATION DATED Authorized Signature rru TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 36831 Date: 11/22/2011 Permission is hereby granted to: Williams P J Rev Liv Trst 4 Hayes Hill Dr Nortport, NY 11768 To: construct an electric solar panel system to an existing dwelling At premises located at: 1110 E Cedar Point Dr, Southold SCTM # 473889 Sec/Block/Lot#90.-2-20 Pursuant to application dated 11/9/2011 and approved by the Building Inspector. To expire on 5/23/2013. Fees: SINGLE FAMILY DWELLING -ADDITION OR ALTERATION $200.00 CO -ALTERATION TO DWELLING $50.00 Total: $250.00 GtiL Building Inspector Form No.6 TOWN OF SOUTHOLD. BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use:. 1. Final survey of property with accurate-location of all buildings,property lines,streets,and unusual natural or topographic features. 2. Final Approval from Health Dept,of water supply and sewerage-disposal(S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. -Swom statement from plumber certifying that the solder used in system contains less than 2110 of I% lead. 5. Commercial building.industrial building,mtdtiple residences and similar buildings and installations,a certificate of Code Compliance-from architect or engineer responsible for the building. .6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings(prior to April 9, 1957) non-coinforming uses,or buildings and"pre-existing"land uses-- 1. ses:1. Accurate survey of property showing all property lines,streets,building and-unusual natural or topographic features. 2. A properly cpmpleted application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied, the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fces 1. Certif cafe of Occupancy- New dwelling$50.00,Additions to dwelling$50.00,Alterations to dwelling$50.00, Swimming pool$50.00,Accessory building$50.00,Additions to accessory building$50.00, Businesses$50.00: 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of.Occupancy-$25 4. Updated Certificate of Occupancy- $50.00 5_ Temporary Certificate of Occupancy -Residential $1.5.00y Commercial$15.00 Date. New Construction: Old or Pre-existiiig Building:' (check one) Location of Property: ///0 Ce dQ{'r. o1 b y • House No. �7 Street Hamlet Ow /ne'r or Owners of Property: r l(Q rnj . Suffolk County Tax Map No 1000,Section_ D B lock Lot Subdivision Filed Map. Lot: Permit No. Date of Permit. Applicant: Health Dept.Approval: Underwriters Approval: Planning Board Approval: Request for: Temporary Certificate Final Certificate: (check one) Fee Submitted: $ _ F LO Applicant Signature o��OF SO(/ry�l Town Hall Annex Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 1179 G • Q roger.richert(a)-town.southoId.ny.us Southold,NY 11971-0959 COUMY,�c� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION Issued To: JohnWilliams Address: 1110 Cedar Point Dr East City: Southold St: NY Zip: 11971 Building Permit#: 36831 Section: 90 Block: 2 Lot: 20 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: Alternative Energy License No: 47537-me SITE DETAILS Office Use Only Residential X Indoor X Basement Service Only Commerical Outdoor X 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures HID Fixtures Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Fluorescent Fixture Pumps Transformer Appliances Dryer Recpt Emergency Fixture Time Clocks Disconnect Switches F1 Twist Lock Exit Fixtures �] TVSS Other Equipment: photovoltaic system, roof mounted, to include 21 solar panels, 1 PVI 5000 inverter combiner box,ac disconnect Notes: Inspector Signature: Date: Feb 13 2012 81-Cert Electrical Compliance Form.xls Pacifico Engineering PC Engineering Consulting PO Box 1448 Ph: 631-988-0000 Sayville, NY 11782 Fax: 631-382-8236 www.pacificoengineering.com engineer@pacificoengineering.com July 24, 2014 Town of Southold Building Department 54375 Route 25, P.O. Box 1179 Southold, NY 11971 Subject: Solar Energy Installation for John Williams 1110 Cedar Point Dr E Southold, NY 11971 1 have reviewed the solar energy system installation at the subject address. The units have been installed in accordance with the manufacturer's installation instructions and the approved construction drawing. I have determined that the installation meets the requirements of the 2010 NYS Building Code, and ASCE7-05. To my best belief and knowledge, the work in this document is accurate, conforms with the governing codes applicable at the time of submission, conforms with reasonable standards of practice, with the view to the safeguarding of life, health, property and public welfare Regards, Ralph Pacifico, PE Professional Engineer �V: NEIN Y Pnci,��c0.4� o cc W W 2�F�A 0660% P�� Ralph OF SS�OCaI Engineer NY 066182 I NJ 24GE04744306 DATESAM CONIlvNTS. � ►a . FOUNPAtION(1ST).. . A POMOATION(2Nru) C) PLUMING INSULATION Pelt 2R.Y. STATE E1+ (;Y+COBE ti ADDITI0-NAL COIWIlI ENTS .�• C.c� L G � o TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board ofHealth n SOUTHOLD,NY 11971 4 sets of Buil ' Plans TEL:(631)765-1802 Planning Board?p roval FAX:(631)765-9502 22 Survey V www.northfork.net/Southold/ PERMIT NO. J Check Septic Form N.Y.S.D.E.C. Tkr tees Examined � 7/20 1(Approved 20Disapproved a/c ! I}'C>!t"2. D, .� Y('L4 �� — o ;� e: 3 � Expiration 5 3 20 3 ` Buil MOV 0IPTH LD APPLICATION FOR BUILDING PERMIT Date G Y / ,20 INSTRUCTIONS a.This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 3 sets of plans,accurate plot plan to scale.Fee according to schedule. b.Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas,and waterways. c.The work covered by this application may not be commenced before issuance of Building Permit. d.Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant.Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for arty purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f.Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date.If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize,in writing,the extension of the permit for an addition six months.Thereafter,a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk County,New York,and other applicable Laws,Ordinances or Regulations,for the construction of buildings,additions,or alterations or for re-MN or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code,housR code,and regulations,and to admit authorized inspectors on premises and in building for necessary inspections. (Signature of applicant or name,if a corporation) (Mailing address of applicant) State whethelicant is owner,lessee,agent,architect,engineer,general contractor,electrician,plumber or builder Name of owner of premises 7 � (As on the tax roll or latest deed) If appli t is a corporation,signature of ly authprized offiger —Name and title of corporate officer) Builders License No. Plumbers License No. Electricians License No. / Other Trade's License No. 43u F j= f k Z Le, 1. Location of 1 don which,,,,,ppro d work will done: I 1 (D bArt, f'OI ,�y . lhs� (iltiy7p N/ Y. f( �7 H&se Number Street Hamlet County Tax Map No. 1000 Section 90 Block q," Lot 6 Subdivision Filed Map No. Lot (Name) • 2. State existing use and occupancy of premises and i tended use and occupancy of proposed construction: a. Existing use and occupancy �Jf 'S/7&W C� b. Intended use and occupancy 4!Rq Pmt 4zgz Koh -IL to✓ tq 3. Nature of work(check which applicable):New Building Addition Al te Oil Repair Removal Demolition Other Work–f escription) 4. Estimated Cost ° Fee (To be paid on filing this application) 5. If dwelling,number of dwelling units Number of dwelling units on each floor If garage, number of cars 6. If business,commercial or mixed occupancy,specify nature and extent of each type of use. 7. Dimensions o existing strictures,if any:Front 1 r Ij 7� Rear_ � Depth CIL(A'— Height FI Number of Stories Dimensions of sarr)e structure with alterat' sr additions: Front `yL Rear Depth 4d��1i Height g FT Number of Stories 8. Dimensions of entire new construction:Front Rear Depth Height Number of Stories 9. Size of lot:Front L D�s� Rear ff .�� Depth � 10.Date of Purchase Name of Former Owner 11.Zone or use district in which premises are situated 12.Does proposed construction violate any zoning law,ordinance or regulation?YES_NO ty 13.Will lot be re-graded?YES_NO)Will excess fill be removed from premises?YES NO_ ot- P7 14.Names of Owner of m'ses� (� Addres*s4c'– � None No ���� '���Name of Architect C b Addres Phone NoName of Contractor , t AddresPhone No. 3 ( D 15 a.Is this property within 100 feet of tidal etland ora freshwater wetland?*YES NO *IF YES,SOUTHOLD TOWN TRUSTEES&D.E.C.PERMITS MAYBE REQUIRE . Wt­fA-6,0 b.Is this property within 300 feet of a tidal wetland?*YES NO *IF YES,D.E.C.PERMITS MAY BE REQUIRED. 16.Provide survey,to scale,with accurate foundation plan and distances to property lines. 17.If elevation at any point on property is at 10 feet or below,must provide topographical data on survey. STATE OF NEW YORK) SS: COUNTYOF , V I U f n being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)He is the �Z1 1 )'-- (Contractor gent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief;and that the work will be performed in the manner set forth in the application filed therewith. SwoM to before me this `^r� p�� day of ! 20 Notary Publi6 Signature of Applicant SUSAN J.SHAFFER Notary Public,State of New York No.4171162 Qualified in Suffolk County1 Commission Expires April 30,20,1, Jill M.Doherty,President Of SO(/lyO Town Hall Annex Bob Ghosio,Jr.,Vice-President 54375 Main Road P.O.Box 1179 James F.King Southold,New York 11971-0959 Dave Bergen `A John Bredemeyer � Telephone(631)765-1892 Fax(631)765-6641 BOARD OF TOWN TRUSTEES TOWN OF SOUTHOLD Permit No.: 7658A Date of Receipt of Application: September 30,2011 Applicant: John Williams SCTM#: 90-2-20 Project Location: 1110 Cedar Point Drive East,Southold Date of Resolutlon/lssuance: October 19,2011 Date of Expiration: October 19, 2013 Reviewed by: Board of Trustees Project Description: To install roof solar panels onto the existing dwelling. Findings: The project meets all the requirements for issuance of an Administrative Permit set forth in Chapter 275 of the Southold Town Code. The issuance of an Administrative Permit allows for the operations as indicated on the site plan prepared by Pacifica Engineering PC, received on October 5, 2011 and stamped approved on October 19, 2011. Special Conditions: None. Inspections; Final inspection. If the proposed activities do not meet the requirements for issuance of an Administrative Permit set forth in Chapter 275 of the Southold Town Code, a Wetland Permit will be required. This is not a determination from any other agency. M. Doherty, President Board of Trustees JMD:eac James F.King,President &0 so, Town Hall Annex Bob Ghosio,Jr.,Vice-President �� l� 54376 Main Road P.O. Box 1179 Dave Bergen Southold,New York 11971-0959 John Bredemeyer G Q • �O Telephone(631)765-1892 Michael J. Domino O��COU Fax(631)765-6641 BOARD OF TOWN TRUSTEES TOWN OF SOUTHOLD CERTIFICATE OF COMPLIANCE #0790C Date: August 23, 2012 THIS CERTIFIES that the installation of roof solar panels onto the existing dwelling At 1110 Cedar Point Drive East, Southold,New York Suffolk County Tax Map#90-2-20 Conforms to the application for a Trustees Permit heretofore filed in this office Dated Member 30, 2011 pursuant to which Trustees Administrative Permit#7658A Dated October 19, 2011 , and conforms to all of the requirements and conditions of the applicable provisions of law. The project for which this certificate is being issued is for the installation of roof solar panels onto the existing dwelling. The certificate is issued to JOHN WILLIAMS owner of the aforesaid property. AutlArized Signature *pG SOUjyol 0 Town Hall Annex Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 1179 G Q Southold,NY 11971-0959 �O ����4UNTY,� July 10, 2014 BUILDING DEPARTMENT TOWN OF SOUTHOLD Alternative Energy Systems c 'It 865 White Eagle Dr Laurel, NY 11948 " Re: Williams, 1110 Cedar Point Dr East, Southold, NY TO WHOM IT MAY CONCERN: The Following Items(if Checked)Are Needed To Complete Your Certificate of Occupancy: + ciion from an engineer stating the panels were fastened to the roof per 1+iYS Building Code Application for Certificate of Occupancy. (Enclosed) Electrical Underwriters Certificate. A fee of$50.00. Final Health Department Approval. Plumbers Solder Certificate. (All permits involving plumbing after 411/84) Trustees Certificate of Compliance. (Town Trustees#765-1892) Final Planning Board Approval. (Planning#765-1938) Final Fire Inspection from Fire Marshall. Final Landmark Preservation approval. Final inspection by Building Dept. Final Storm Water Runoff Approval from Town Engineer BUILDING PERMIT — 36831 — Solar Panels of so�ryol 0 Town Hall Annex Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 1179 G • Southold,NY 11971-0959 �Q 100UNTY,� July 16, 2014 BUILDING DEPARTMENT TOWN OF SOUTHOLD Williams Family Trust 4 Hayes Hill Dr Northport NY 11768 Re: 1110 Cedar Point Dr East, Southold TO WHOM IT MAY CONCERN: The Following Items(if Checked)Are Needed To Complete Your Certificate of Occupancy: **NOTE: This building permit is still open as we never received the certification from an engineer regarding the panels being installed per NYS Building Code Application for Certificate of Occupancy. (Enclosed) Electrical Underwriters Certificate. A fee of$50.00. Final Health Department Approval. Plumbers Solder Certificate. (Ali permits involving plumbing after 4/1/84) Trustees Certificate of Compliance. (Town Trustees#765-1892) Final Planning Board Approval. (Planning#765-1938) Final Fire Inspection from Fire Marshall. Final Landmark Preservation approval. Final inspection by Building Dept. Final Storm Water Runoff Approval from Town Engineer BUILDING PERMIT — 36831— Solar Panels si► GENERAL NOTES Roof Section A ARMED A6 NOT19 mean roof height 26 it 131 Pilch 4 W12 .=ON1gTCTORLMLLCIEG[MO`/EItFYRL1,EQNpffO1L4ATT E t,.TMEOV.lEM9YYL9ElECTsil.iN3M4MTERW.S.wDCOIOrsY roof rafter 200 DATE- I B.P. a+F mKv+msrAerw;mryaecAwxswai FAABI wevF �T.TMB6E ORAvw1c6 AB er6rauAEryrs o<6Ear,CE ARE AFD BMus wae�rwimne►na..orT,+esB.,ww.wwux.wroc r€r�wiMfrwrenTvaFi�eMc�axrFn,FnTrevao,rFCT raRersPaCing 161nOC '�`•E""TM•'"F- ton-*C.TKI Ane Mace eOft WT.TnBr tae Reflected roof rafter n p x m+mA=raRoaaM,casMALLaeiAnuLREa.+FOAPw,ovas. wiiosBusEoowAMron+BvaaaBcrsa+niasowsio ape 15.4 It PE""6`E""CAtE3OfOG ""_ TM6P ^° -` T� •� �^ Table R802.5.1(1)max allowable 20.6 rt FEE: APPaaa�B.t�c..row woa«PnrcowA4o r+,ou.eEAccz wA�ac AP�oABAa=aAORMBAT,=MTaT,� ,. NOTIFY BUILDING DEPARTMENT AT wwaoer,n,n,EBE=F.s RErw.en. n.cwm,e-caswi�+orta.o,rawo�onu�ra•+e,c.ra«.orrnnrowwove collar tie 2x4 a Au worst sMAu ooMFawmcouraucr,ow coos AMe oR O,wr�KR"d.lr=F"61pi6. <K Enaos or"�ca siw clan w :uxi a aewn uraavw� �cowu r row e x s xAn.wrua+ color W spacng 48 in OC BLPE •rT�=«rt•� �^ °�^^�° • � 7 02 8 AM TO 4 PM FOR THE s.6MT11EcouRse rY oOMSTRUCT1nNA OCrtarrro.Fawn naw,Rrrarotr,Fer.uowwrw.mwurerE.Cax,B,c•oRBLwem.ncreowvs wnra,wnoreEB•miH rw,r,u wrCArSo aM T,resE•,Ar s. co.Fc:RI.COIRFTEDCYiie,[M rrc amow�FU TrsnnFoo<sor TRB PRas=TMn „���rT•.cT=n�,Ar.s<n�,�AK,�,,,�,T,� ��,�ra>,�,�roB.•,,,�B SPECTIOPJ 3rrouLo nE rAnmwuow*no PnocEnne AAp=Or.TM1E xe,asur,A,ia,:raw.�ce�mswtraawanwwssr*va r�.aa c,[awwc EwdY.MB9WAABBUAEAUREBFpgBBrrAq � -YmMnERcwossAMSQRJ95i f �wB.n.i,��F�,. «�,,,�:B,�T,..�,�„�,�.r,�,M�s�..�r•n,�,�i�,o �- 1. FOU N-TWV' REQUIRED 6.ALL9IRIILTWtKS1EElBMKlEA3l,M5lMlI.BE racowwa �raw>EHaasrfasxrc. TvwirsrrosFw�roorau, �2 FABS„>EOAr�..BTA,.���,uTB�T,,s< .�,�.r•n,�,��r�:ur�B�r�r. p � ED CONCRETE Breur,unora rraaa arrr9d�s sw:eorFxx m r�rscwe duwxs.vs�F n�rauasu� i- MCx+iBF�56oi1Fa�wlsLFwiTFr1NAT1=NALOYPBU.COfrA' EVAM&ftByEMWCONDMOWEA COWRAG70RNwLVMFYEXETMC4 VDD \3EE OF—T.2. NV .PLUMBING, Orow'�� !r- 2 RORAPPINR M'LE—ELECTRICAL 8 CAULKING L=oNvAmTrm rmsOPMT 0%E LWORAminTnEREWROP TRX N1 ST COOtBt NEOULATxOr,i. nflTW AOd,CE4T IK11r[$CE OFCOr6BW1LEE DEsm AND dMro mLKLY AGXSS 1 �7 9 ANY OEVNTgk FROM TNEBE PLAM4 NrinOUT Tw=vNeTTEH mkTRACRM SnNIItEB 8RE n43 OF LOMSTRULTgN 0E4tlBNO10£VSIrE FULLY s CCwsenr orTK EMawtR w,u r,EGAiE TrE EIrO•EE119 LO iRE PIHCOURBGK3MSOF OPERAT1rM �`•” 3, INSULATIO CBRTiFICATION aF Tr6SB PLAYS. n cox,Ru:*rn m RrA,F mi nreNsa,FATFp Rr TKs mre moa„F sm AMI oePnsF rx ,O.nE GENERK CONTI+AC,OR SWLLL BE re=swBrse�E wrL currwc. xn,EUV NVBEn aB Av7Egar xa5oB 5ous+rcanprgns traPA,wr SEE DEET- '1 rrtrrxx oR PAmurC atouwcn To cow�Crc n,c woac oRm Want careroRawa�aL Tr[snEaroeE aEARm CFAU OE6R6Ar4)EALE35 4. FINAL-CO y ST RU���1���F� � MNtE ITS PAeiS AT TO(#T,ER Pf.YWEieY- wmws.T'c rALBliy is Tom LIT w4m a&E AND WRBBl mmm mwvmmMPLE. `� N.T.S Tg TOTM SATVACr4k OF T<MNER PR*R TO RaFABE OF FHst PAYYENf MUST BE ALL CO'47RUCTION SHALL MEET H YORK STATE F--PONS" & F FOR DESIGN OR CGS&UCTION ERRORS. ARRAY INVERTER METER OCCUP, 'CY UR ji O SERVICE �-✓ I LAW F L PANEL AC AC DC CERTIFICAT C� IPANCY TYPICAL RISER DI t `` RiCAL INSPED71aN REQUIRED RiSER 0iA4RAM SHOWN FOR REFERENCE 5aratinLnr Rai - ` Al 3olce+,a.,,Rai To my best belief and information the wo*in this document is accurate,confomhs with theMRbl.4govemirp codes applicableat the time of sirbrnission,conforms with replsgm*.standardsTYPICAL CONNECTION DETAIL 1 ALL ROOF PENETRATIONS ARE TO 8E SEALEDPV PANEL WITH SIKAFLEX OR EQUIVALENT SEALANT of practice,with the view to the safeguarding of Slee,heakh,property and pt�l'I� 7rr. "ALVAand is the nsibll' ofthe Scensee. vmn, I as per AS 7_Method 1: A 1.36 1 bie s.t 1 wPACIFIC0 ENGINEER NQ EC Pr.r= a Pnr3o(ea':4 (w 6.5.7) 1 Pna36(r9 6-3) -47.8 t�Orr NLiy y0 PO BOX 1.448,SAYOLLE,NY 11752 CLIMACTIC AND Ground WndSpeed, Livebed, 64uR an gtP P�4e� e:631 010 99-00 Fair.631-382-8236 Enwil: inee iFrt tt ivw ' .Lo GEOGRAPHIC DESIGN Ca6npory Sro Load, 3 sec gust pmt3o per Qe'nt Pu b�bmut Fastener type specino Blew * • '".. CRITERIA Pg mph ASCE 7,pd .&.in n W John W/IffAWls Roof Section A C 20 120 66 720 5/1 dia screw, ngth 48 ' 1110 Cedar Point Dr E,Souti o(d,NY 114171� ^PROPOSED SOLAR ENER4Y INSTALLATION �D1.oO RepR PBdllm,Pr•rsBE16nY S [B,*—vb. 4ENERAL NOTES,ROOF SECTION,DATA,DETAILS AND SPECS NV 0661621 NJ 24GED4744306 O4/Se/u q5 NOTED 1 oft (I�eir `�>i'°i:w Sar e.e `ti ie �.�� �i.e.e ��.eu.• w Ig,l t— Plur:b rq V:,rt to be novEtl to front resp{ I i I i I I I I i I I I I I i i I ROOF LAYOUT "" PV Panel ���NEW y PO Box 1448,SAYVILLE,NY 11782 A ��' PSR Q e:6 31-9 8 8-00010 Fax:631-382-8236 Emdf: ince ifit in" ' .Com Kyocera a JOkn Wiffi4rAS PANEL: KD245 W QTY: 21 a' 1110 Cedar Point Dr E,Soattwid,NY 11471 dR0 1e1 �r0 POSS-002-00 I nave'eviewed me ra"Wwtk e d#m wbod Odd—The Ouch-nn mww the addhonm~4 LENGTH: 65.43 in POSSOLAR EMER4Y INSTALLATION d U.,..f m—d d pW..The u.Vm are Io ba aat kd In..-bots aft the man d clmer'e hnldm- WIDTH: 38.98 In - 4ENERAI.NOTES,ROOF SECTION,DATA,DETAILS AND SPECS k.bwfia I have d.Wn*ed Inst tha inet M-a'i meat d*nequhemente a1 the 2010 NYS Mft Ralph P,A—Preteuimd EnOin eade,sad nseE7-0s vdwn nsta8ed acardwce aNh the marodach8er:In:trucaw:. TT • 5145 NY OW182I w 2�7443W 04/18/11 As NOTED 2 of 2 GOEENEFLAL NOTES Roof section A mean roof height 26 ft pitch 4 in/12 1. CONTRACTOR SHALL CHECK AND VERIFY ALL CONDITIONS AT THE 11.THE OWNER SHALL SELECT ALL FINISH MATERIALS AND COLORS. roof rafter 2x10 SITE PRIOR TO STARTING TO WORK AND SHALL FAMILIARIZE 12.THESE DRAWINGS AS INSTRUMENTS OF SERVICE ARE AND SHALL HIMSELF WITH THE INTENT OF THESE PLANS AND MAKE WORK REMAIN THE PROPERTY OF THE ENGINEER WHETHER THE PROJECT rafter spacing 16 in OC AGREE WITH SAME. FOR WHICH THEY ARE MADE IS EXECUTED OR NOT. THEY ARE Reflected roof rafters an 15.4 ft 2. CONTRACTOR OR OWNER SHALL OBTAIN ALL REQUIRED APPROVALS. NOT TO BE USED ON ANY OTHER PROJECTS OR EXTENSIONS TO P PERMITS,CERTIFICATES OF OCCUPANCY,INSPECTION THIS PROJECT EXCEPT BY AGREEMENT IN WRITING AND WITH Table R802.5.1(1) max allowable 20.6 ft APPROVALS.ETC..FOR WORK PERFORMED FROM AGENCIES HAVING APPROPRIATE COMPENSATION TO THE ENGINEER. JURISDICTION THEREOF,IF REQUIRED. 13.CONTRACTOR SPALL PROTECT,PATCH AND REPAIR ALL EXISTING WORK ADJACENT TO HIS WORK, collar tie 2x4 3. ALL WORK SHALL CONFORM TO CONSTRUCTION CODE AND OR DAMAGED AS RESULT OF HIS WORK. ALL RULES AND REGULATIONS OF THE RESPONSIBLE JURISTICTION. 14.THE SUBCONTRACTORS SHALL PROVIDE ALL EGUIPMENT,TOOLS FENCES.TRANSPORTATIONS, collar tie spacing 48 in OC 4. ALL METHODS OF CONSTRUCTION ARE TO BE CAREFULLY SAFEGUARDS,ETC-AS REOUIIED FOR THE PROPER EXECUTION OF THEIR WORK. �� SUPERVISED BY THE CONTRACTOR. 15.CONTRACTOR TO EFFECT AND MAINTAIN INSURANCE.I.E.CONTRACTOR'S LABILITY,WORKMA14S + t 5. IF Id THE COURSE OF CONSTRUCTION A CONDITION EXISTS LJ a •"`Q I �, - WHICH DISAGREES WITH THAT AS INDICATED ON THESE PLANS. COMPENSATION.COMPLETED OPERATION.ETC.ADEQUATE FOR THE PURPOSES OF THIS PROJECT AND THE CONTRACTOR SWILL STOP WORK AND NOTIFY THE ENGINEER. FURNISH PROOF OF SALE PRIOR TO COMMENCING WITH WORK SHOULD HE FAIL TO FOLLOW THIS PROCEDURE AND CONTINUE 16.EACH SUBCONTRACTOR SHALL BE RESPONSIBLE FOR MAINTANNG SAFETY ON THE JOB SITE DURING WITH THE WORK,HE SHALL ASSUME ALL RESPONSIBILITY ,AND THE CONSTRUCTION PHASE TO COMPLY WITH THE REGULATIONS AND REQUREMENTS OF THE moi- + ` 0. A LA W F L LIABILITY THEREFROM. OCCUPATMAI.SAFETY AND HEALTH ADMINISTRATION.THIS SHALL INCLUDE,BUT ARE NOT LIMIT ED TP. 12 / 6. ALL STRUCTURAL STEEL SHALL BE A-36 AND SHALL BE PROVIDING FOR ADEQUATE AND PROPER SWING,SAFETY RAILINGS AND SECURE FOOTINGS FOR ALL - ' !� .�T C E R T i F 1 G A T FABRICATED AND INSTALLED AS PER LATEST A.I.S.C. TEMPORARY SCAFFOLDING STAIRS E'C AS WELL AS PERMANENT CONSTRUCTION. v SPECIFICATIONS. 17.FIGURED DIMENSIONS SHALL GOVERN.DO NOT SCALE DRAWINGS.WHERE DIMENSIONS ARE --� 7. ALL DRYWALL SHALL BE U.S.G.NATIONAL GYPSUM CO.518' ESTABLISHED BY EXISTING CONDITIONS,EACH CONTRACTOR SHALL VERIFY EXISTING CONDITIONSY— \ AN'/1 THICK UNLESS OTHERWISE NOTED. PRIOR TO ORDERING MATERIALS AND COMMENCING RK GWITHWO . SEE DET. 1 i i...�` i S. ALL ELECTRICAL WORK SHALL BE BOARD OF FIRE UNDERWRITERS 18.CONTRACTOR SHALL COORDINATE ALL PHASES OR WORK WITH THE REQUIRED PARTIES.ALL APPROVED AND A ACCORDANCE WITH N.E.C.b NYS PHASES OF ADJACENT FACILITIES OPERATIONS SHALL BE MAINTAINED DURING CONSTRUCT . 9.ANY DEVIATION FROM THESE PLANS WITHOUT THE WRITTEN / CODES REGULATIONS. CONTRACTOR SHALT.KEEP SITE FIFE OF CONSTRUCTION DEBRIS AND KEEP SITE FULLY ACCESSIBLE CONSENT OF THE ENGINEER WILL NEGATE THE ENGINEER'S TO THE PUBLIC DURING HOURS OF OPERATION.CERTIFICATION OF THESE PLANS. 19.CONTRACTOR TO REMOVE ALL DEBRIS CREATED BY THIS WORK FROM THE SITE AND DISPOSE OF SEE DET. Roof Cross Section 10.THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR CUTTING, IN A LEGAL MANNER OMA WEEKLY BASIS OR SOONER P CONDITIONS WARRANT. FITTING OR PATCHING REQUIRED TO COMPLETE THE WORK OR TO 20,AT THE COMPLETION OF WORK,THE SITE IS TO BE CLEARED OF ALL DEBRIS AND EXCESS MAKE IT'S PARTS FIT TOGETHER PROPERLY. MATERIALS.THE FACILITY IS TO BE LEFT BROOM CLEAN AND WORK IS TO BE COMPLETED TO N.T.S THE TOTAL SATISFACTION OF THE OWNER PRIOR TO RELEASE OF FINAL PAYMENT. PROVED�ASNOTED) C� - —BIB ARRA =$ /' = INVERTER METER +_ "("� Ai✓1 - �f'r iVl�?FOR t LI_[yqi NC I Rte; O7,'(0jh r SERVICE ,;. PANEL C. �-=t�:.► :�r.r= • AC AC DC DC 4 F/R�4 % ? i+ l '11 cg ELLr'2rA M U5'Y BE MicClamp / 6AfS1 N2Ui+51 Mt> THC TYPICAL CAL RISER DIAGRAM RAM ` '` "��` � =--�- - N.T.S. Enc Clomp toot -'.- RISER DIAGRAM SHOWN FOR REFERENCE ELECTRICAL INSPECTION REOUIRED Sol(XMount Rai ,.� Revisions -4�� soiorAAOL,n1 Rai To my best belief and information the work in this document is accurate, conforms with the Revis-4 governing codes applicable at the time of submission,conforms with reasonable standards Revision 3 TYPICAL CONNECTION DETAIL 1 ALL ROOF PENETRATIONS ARE TO BE SEALED of practice, with the view to the safeguarding of life, health, property arid'06bliewelfare, RevWw 2 PV PANEL WITH SIKAFLEX OR EQUIVALENT SEALANT and is the responsibility of the licensee. ReyWon 1 9rzE111 update panel count as per ASCE7, Method 1: (fig 6-2) 1.36 1 (table 65-1) 1 Sam- �= PA 1 t O ENGINEERING P p net =A KZt/p rW30(eq 6-2) Kt(sec 6.5.7) 1 pnet3o(fig 6-3) -47.9 ��. E�,V Y PO Box 1448, SAYVILLE, NY 11782. p.ACIF CLIMACTIC AND Tel: 632-988-0000 Fax: 632-382-8236 Entail: a itneer@ acificoe ilLeeri cowl Ground Wind Speed, Live load, Maximim �� iC pullout point p GEOGRAPHIC DESIGN Category Snow Load, 3 sec gust, pnet30 per pFastener type fastener .01 �Jl.F��' s O , CRITERIA Pg mph ASCE 7,psf bad,Ib spaGnga" ! Cf f� John Williams in LL Roof Section A C 20 120 66 720 5/16"dia screw, 4" length 48 =i z 2220 Cedar Point Dr E, Soutkold, NY 22972 PrjaDrae V& 5 --001.00 !�= PROPOSED SOLAR ENERGY INSTALLATION :.� 0 6 6 4' p� GENERAL NOTES, ROOF SECTION, DATA, DETAILS AND SPECS Ralph Paas gineer u, NY 066182( 04744306 04/18/11 I AS NOTED I. OF 2 10 — 24'- 5" --� r'a N F-M—N rp..N fv—w twosN rye.N r,—w ffi'M Mir *Jr 3P Ir ISA-r M M3 'n ON wo M% M lm3 am an rm3 W35 F" to RN5 at im5 am R5 4M �5 •N r N r •N N r N r w r w M m 3 r®o to IM W35 am I" In � mac 9" a4 I" r4 11w Imo IM am ale I" 1" m5 rm5 am m+a � Irw, m75 rWMIV ry.e,w r .N ry,uNN Mln n rprer'N grrew N C 39Y,B56' I30 n a.H�'.ES�z sm'.mc' D1.R.i5 r7 3.W,c�.r' Kn.6.G' rmir �3 M In 4% 1&1 X90 mE9i I rM I" I" IM t" am am FM we 4M TM ale lmb lm5 rm5 04 lm4 rra15 1C4 Plunbin9 vent to be novel to front roof ROOF LAYOUT "°""k"Se'` PA 1 1 O EN INEE IN P PV Panel F�EW y� PO Box 2448, SAYVILLE, NY 11782 A ��QN PAC/F/CO�� TO: 631-988-0000 Fax: 632-382-8236 Email: a ineer@ acifieoe itteeri .eom Kyocera �� K 1 'r- John Williams PANEL: KD245 LU QTY: 21 - Z 111.0 Cedar Point Dr E, Southold, NY 11972 _002.00 a � LENGTH: 65.43 in `" ? PROPOSED SOLAR ENERGY INSTALLATION I have reviewed the roofing structure at the subject address.The structure can support the additional weight 066 8 �.,g�°a`~ of the roof mounted system.The units are to be installed in accordance with the manufacturers installation WIDTH: 38.98 in '' P GENERAL NOTES, ROOF SECTION, DATA, DETAILS AND SPECS instructions.1 have determined that the installation will meet the requirements of the 2010 NYS Building Ralph 0Paa `P�pf¢sg¢g eer s�rG Code,and ASCE7-05 when installed in accordance with the manufacturers instructions. WATTS: 5145 NY 661821' 44306 04/18/11 AS NOTED 2 of;z HIGH EFFICIENCY MULTICRYSTAL PHOTOVOLTAIC M KYGEERa Ka 200- 60 P Series ' KD230GX-LPB KD235GX-LPB KD240GX-LPB KD245GX-LPB CUTTING EDGE TECHNOLOGY As a pioneer with over 35 years in the solar energy industry,Kyocera demonstrates leadership in the development of solar energy products.Kyocera's Kaizen Philosophy,commitment to continuous improvement,is shown by repeatedly achieving world record cell efficiencies. QUALITY BUILT IN • UV stabilized,aesthetically pleasing black anodized frame • Supported by major mounting structure manufacturers • Easily accessible grounding points on all four corners for fast installation • Proven junction box technology with 12 AWG PV wire to work with transformerless inverters • Quality locking MC4 plug-in connectors to provide safe and quick connections RELIABLE • Proven superior field performance • Tight power tolerance • Only module manufacturer to pass rigorous long-term testing performed by TOV Rheinland WARRANTY QUALIFICATIONS AND CERTIFICATIONS • Kyocera standard 20 year power output � i warranty and 5 year workmanship warranty UL Listing C@US (�,;=''y applies in USA QIGU.E173074 Registered to IS09001-2000 • Extended warranties available per project NEC 2008 Compliant,UL 1703,ISO 9001,and ISO 14001 requirements UL1703 Certified and Registered,UL Fire Safety Class C,CEC,FSEC • Kyocera standard 20 year power output Certified IEC61215 Ed 2 IEC61730 by JET warranty and 2 year workmanship warranty QUALIFIED FOR "BUY AMERICAN" applies outside of USA Manufactured in San Diego, California • Refer to Kyocera warranty policy for details • Available Upon Request • SOLARbyKYOCERA KD 200-60 P Series, ELECTRICAL SPECIFICATIONS MODULE CHARACTERISTICS Dimensions: 65.43in/38.98in/1 Sin length/width/height (1662mm/990mm/46mm) Weight: 46.3lbs(21.Okg) P. 230 235 240 245 W V,. 29.8 29.8 29.8 29.8 V PACKAGING SPECIFICATIONS IM 7.72 7.89 8.06 823 A Modules per pallet 20 V 36.9 36.9 36.9 36-9 V Pallets per 53'container: 36 Pallet box dimensions: 66-54in/39.76in/47.24in tx 8.36 8.55 8.59 8.91 A lengthAm&h/height (1690mm/1010mm/1200mm) P.. +5/-3 +5/-3 +5/-3 +5/-3 % Pallet box weight 1050 lbs(480kg) TN. 45 45 45 45 °C POTTED hJUNCTION Pn- 165 169 172 176 W Box(lrss) 3 � V 26.8 26.8 26.7 26.8 V CABLE LABEL CONNECTOR (-� '-{- 1� 6.18 6.31 6.45 6.58 A g STABILIZER BAR d V. 33.7 33.7 33.7 33.7 V Note cable length changes: (-)37.8in/960mm IX 6.77 6.92 6.95 7.21 A (+)46.9in/1,190mm PTC 208.0 212.6 217.3 219.1 W 3� d STABILIZER BAR P. -0.45 -0.46 -0.46 -0.46 %/'C e V,,,p -0.51 -0.52 -0.52 -0.52 %/°C I� 0.0065 0.0065 0.0064 0.0065 %/°C V. -0.36 -0.36 -0.36 -0.36 %/°C 1. 0.060 0.060 0.060 0.060 %/°C T T'P ting -40 to+90 -40 to+90 -40 to+90 -40 to+90 °C ° 1 LILY I Maf Yr Liam^I Series Fuse Rating15 A Maximum DC System Voltage(UL) 600 V L�L' �io:� Hailstone Impact 1 in(25mm)@ 51 mph(23m/S) Ewnded New of Ora Indio,Hdes Frmn Cnm Seceon q gran -Suhlexl to vfnulator mcasufcnacnt waeea Uwity of�i-3 f,Y:?(:ERA resrrvcs the i jht tc modify thew orf ificatiom without ooti<c. &7- nRurrfc zeadtheiraucior, Legend NEC 2008 COMPLIANT 1.@ US A ® ® vanits en5rtyproUL 1703 LISTEDEhandling,inrialling&opera[ O MOUNTING HOLES DRAINAGE HOLES ±BGROUNDSYMBOL CERTIFIED IEC61215 ED2 IEC61730 BY JET lw9ooi zono ~` ny Iyuc�a Solar rnod.!ies .351n(9mm) .351n(9mm) 081211 OUR VALUED PARTNER KYOCERA Solar, . . • Technical . . . - - UNIRAC" SolarMount Technical Datasheet Pub 110818.1td V1.0 August 2011 SolarMount Module Connection Hardware.................................................................. 1 BottomUp Module Clip.................................................................................................1 MidClamp ....................................................................................................................2 EndClamp....................................................................................................................2 SolarMount Beam Connection Hardware......................................................................3 L-Foot...........................................................................................................................3 SolarMountBeams..........................................................................................................4 SolarMount Module Connection Hardware SolarMount Bottom Up Module Clip Part No. 302000C Washer Bottom Up Clip material:One of the following extruded aluminum Bottom Nut (hidden..sgs alloys: 6005-T5,6105-T5,6061-T6 t up Clip - Ultimate tensile: 38ksi,Yield:35 ksi • Finish: Clear Anodized v Bottom Up Clip weight: —0.031 lbs(14g) "Bolt • Allowable and design loads are valid when components are Beam assembled with SolarMount series beams according to authorized UNIRAC documents • Assemble with one%"-20 ASTM F593 bolt,one%"-20 ASTM F594 �.� serrated flange nut,and one%"flat washer • Use anti-seize and tighten to 10 ft-lbs of torque Resistance factors and safety factors are determined according to t� part 1 section 9 of the 2005 Aluminum Design Manual and third- "' party test results from an IAS accredited laboratory • Module edge must be fully supported by the beam * NOTE ON WASHER: Install washer on bolt head side of assembly. DO NOT install washer under serrated flange nut Applied Load Average Allowable Safety Design Resistance Direction Ultimate Load Factor, Load Factor, + lbs(N) lbs(N) FS lbs(N) 4) Tension,Y+ 1566(6967) 686(3052) 2.28 1038(4615) 0.662 Y , Transverse,X± 1128(5019) 329(1463) 3.43 497(2213) . 0.441 ►X Sliding,Z± 1 66(292) 27(119) 1 2.44 j 41 (181) 1 0.619 Dimensions specified in inches unless noted a SolarMount Mid Clamp Part No.302101 C,302101 D,302103C,302104D, 302105D,302106D \ rra Bolt Mid clamp material: One of the following extruded aluminum Mid la Nu alloys:6005-T5,6105-T5,6061-T6 Clamp Ultimate tensile: 38ksi,Yield:35 ksi 2. Finish:Clear or Dark Anodized • Mid clamp weight: 0.050 lbs(23g) • Allowable and design loads are valid when components are assembled according to authorized UNIRAC documents • Values represent the allowable and design load capacity of a single mid clamp assembly when used with a SolarMount series beam to retain a module in the direction indicated • Assemble mid clamp with one Unirac W-20 T-bolt and one W-20 ASTM F594 serrated flange nut Beam �4 Use anti-seize and tighten to 10 ft-lbs of torque • Resistance factors and safety factors are determined according to part 1 section 9 of the 2005 Aluminum Design Manual and third- party test results from an IAS accredited laboratory Applied Load Average Allowable Safety Design Resistance 00Dtssprirr - Direction Ultimate Load Factor, Load Factor, `=WEEN mo #,.. lbs(N) lbs(N) FS lbs(N) 0 Tension,Y+ 2020(8987) 891 (3963) 2.27 1348(5994) 0.667 Transverse,Z± 520(2313) 229(1017) 2.27 346(1539) . 0.665 Sliding,X± 1 1194(5312) 490(2179) 1 2.44 1 741 (3295) 1 0.620 ►X Dimensions specified in inches unless noted SolarMount End Clamp PartNo.302001 C,302002C,302002D,302003C, 302003D,302004C,302004D,302005C,302005D, 302006C,302006D,302007D,302008C,302008D, 302009C,302009D,302010C,302011 C,302012C 0End clamp material:One of the following extruded aluminum alloys:6005-T5,6105-T5,6061-T6 It 0 Ultimate tensile:38ksi,Yield:35 ksi Finish:Clear or Dark Anodized .. f End clamp weight:varies based on height:-0.058 lbs(26g) .Enid Clamp Allowable and design loads are valid when components are Serratedassembled according to authorized UNIRAC documents Flange Nut Values represent the allowable and design load capacity of a single end clamp assembly when used with a SolarMount series beam to retain a module in the direction indicated • Assemble with one Unirac W-20 T bolt and one W-20 ASTM F594 r serrated flange nut Use anti-seize and tighten to 10 ft-lbs of torque ` 1 Resistance factors and safety factors are determined according to part 1 section 9 of the 2005 Aluminum Design Manual and third- Y party test results from an IAS accredited laboratory ` x Modules must be installed at least 1.5 in from either end of a beam .� Applied Load Average Allowable Safety Design Resistance Direction Ultimate Load Factor, Loads Factor, ` lbs(N) lbs(N) FS lbs(N) 0 JAP:Ei Tension,Y+ 1321 (5876) 529(2352) 2.50 800(3557) 0.605 Transverse,Z± 63(279) 14(61) 4.58 21 (92), 0.330 Sliding,X± 142(630) 52(231) 2.72 79(349) 0.555 Dimensions specified in inches unless noted SOLARMOUNT Technical D. - - U UNIRAC SolarMount Beam Connection Hardware SolarMount L-Foot Part No. 304000C, 304000D • L-Foot material:One of the following extruded aluminum alloys:6005- T5,6105-T5,6061-T6 • Ultimate tensile:38ksi,Yield:35 ksi 0 Finish:Clear or Dark Anodized • L-Foot weight:varies based on height:^0.215 lbs(98g) • Allowable and design loads are valid when components are Bea assembled with SolarMount series beams according to authorized Bolt UNIRAC documents L-Foot For the beam to L-Foot connection: •Assemble with one ASTM F593%7-16 hex head screw and one errated ASTM F594 Wserrated flange nut Flange N •Use anti-seize and tighten to 30 ft4bs of torque • Resistance factors and safety factors are determined according to part 1 section 9 of the 2005 Aluminum Design Manual and third-party test Y results from an IAS accredited laboratory A NOTE: Loads are given for the L-Foot to beam connection only;be X sure to check load limits for standoff,lag screw,or other attachment method Applied Load Average Safety Design Resistance A!40T Direction Ultimate Allowable Load Factor, Load Factor, lbs(N) lbs(N) FS lbs(N) 4) Sliding,Zt 1766(7856) 755(3356) 2.34 1141 (5077) 0.646 Tension,Y+ 1859(8269) 707(3144) 2.63 1069(4755) 0.575 Dimensions specified in inches unless noted I Compression,Y- 3258(14492) 1325(5893) 2.461 20 4(8913)1 0.615 Traverse,Xt 1 486(2162) 213(949)1 2.2$ 323(1436) 0.664 SOLARMOUNT Technical Dat. - - Mae UNIRAC SolarMount Beams Part No. 310132C, 310132C-B, 310168C, 310168C-B,310168D 310208C, 310208C-B, 310240C, 310240C-B, 310240D, 410144M, 410168M, 410204M, 410240M Properties Units SolarMount SolarMount HD Beam Height in 2.5 3.0 Approximate Weight(per linear ft) pif 0.811 1.271 Total Cross Sectional Area in' 0.676 1.059 Section Modulus(X-Axis) in3 0.353 0.898 Section Modulus(Y-Axis) in' 0.113 0.221 Moment of Inertia(X-Axis) in 0.464 1.450 Moment of Inertia(Y-Axis) in" 0.044 0.267 Radius of Gyration (X-Axis) in 0.289 1.170 Radius of Gyration (Y-Axis) in 0.254 0.502 SLOT FOR T-BOLT OR SLOT FOR T-BOLT OR 1.728 4"HEX HEAD SCREW %"HEX HEAD SCREW 2X SLOT FOR SLOT FOR BOTTOM CLIP 2.500 BOTTOM CLIP 3.000 1.316 SLOT FOR 0SLOT .LJ -TI 3/8"HEX BOLT FOR 1.385 HEX BOLT .387 .750 1.207 Y Y 1.875 A l .x ►x SolarMount Beam SolarMount HD Beam Dimensions specified in inches unless noted ® AU RORA aD�rer `�77 -one Photovoltaic Inverter ging the Shape of Power k�grn General Specifications ' Outdoor Models � � PVI-5000-OUTD-US PVI-6000-OUTO-US r E . High-Efficiency, 5kW to 6kW Inverters Installer Friendly Aurora®grid-tie transformerless inverters offer a unique combination of •Reverse-polarity protection minimizes potential damage caused by ultra-high efficiencies, installer-friendly designs, long service life, and miswiring during installation. competitive initial acquisition costs; significantly increasing return on •Front-panel mounted LCD display provides real-time updates for all investment in solar-power installations. critical operating parameters. •RS-485 and USB communications interfaces. Industry-leading Features and Performance •Integrated DC switch available in compliance with NEC Standard, •High efficiencies deliver more energy—up to 97%(96,5 CEC). Article 690"Solar Photovoltaic System"(USA) •Two inputs with independent MPPTs, optimize power from multiple •Anti-islanding protection arrays oriented in different directions. •Compact size and high power density:6000W max of output power in Models AC Power a box just 38 5/8"x 1213/16 x 711/16" PVI-5000-OUTD 5kW Unmatched Applications flexibility 66"6� 6kW •Full-rated power available up to 50°C ambient temperature. •Dual input sections with parallel option,with independent high-speed Aurora Communicator software simplifies monitoring via PC. MPPTs, optimize energy harvesting from multiple arrays oriented in Aurora Easy Control datalogger is available for remote control different directions. via Internet,modem or GSM •Wide MPPT operating range:90 to 58OVDC Field-Proven Reliability •IP65(NEMA 4)rated enclosure withstands the harshest environmental conditions. •Front-mounted heat sink resists contamination,enhancing cooling and increasing reliability and long-term efficiency. •Grid-connected operation according to international standards, UL1741AEEE1547&CSA-C22.2 N.107.1-01 •Ten-year warranty,optionally extendable to fifteen and twenty years. ® AURORA Photovoltaic Inverter WChonging the Shope of Power High Efficiencies Across a Broad 1 ` Range of Operating Conditions 97 PVI-5000 and PVI-6000 inverters provide 208/240/277 9618 Vac selectable outputs,at up to 97%efficiency(CEC 96,5 96.5).The graph to the right demonstrates the high 75% 96,2 efficiencies, across a continuous range of input , voltages and load conditions,for the PVI-6000. 95,9 The graphs below depict the industry-leading 95,8 performance of all models at three discrete 50% 95,3 MPPT voltage reference points, and a continuous 95 range of load conditions. 94,7 IL'$ 30% � {„ N 94,4 94,1 93,8 • 20% 93,5 93,2 92,9 9!, ' 1096 92,6 250 300 345 400 480 DC Voltage(V) 1 ------------------------r---- ----- -------- --- a- , ----- v 85 w 80 "'--250V 75dc 480 Vdc 70 0 01 0,2 0,3 0,4 0,5 0,6 07 0,8 0,9 1 %of Rated Output Power AURORA ao�ver-o�►e `1Chonging the Shope of Power Photovoltaic Inverter INPUT PARAMETERS DC Side Nominal DC Power[kWl 5.15 1 6.18 Total Max.Recommended DC Power k 5.3 6.4 Operatina MPPT Input Voltage Range M 90 to 580 360 nominal Full Power MPPT Range M 140-530 1 170-530 Max.Input Voltage 600 Activation Voltage 200 nominal adjustable within 120-350 No Of Independent MPPT Trackers 2 Max.Input Power Each MPPT NIAA 4 4 No.Of DC Inputs 2 1 each MPP 2 1 each MPPT Max.DC Current Each MPPT A 18 22 short circuit 18 22 short circuit Thermally Protected DC Side Varistor 4 2 for each MPPT DC Switch Integrated Ratin :600Vdc/25A 4(2 POSITIVE,2 NEGATIVE) DC Connections SCREW TERMINAL BLOCK 3 KNOCK-OUTS:Gi&1/2"or G1"(using ring reduction) CONDUCTOR CROSS SECTION:MAX AWG4 OUTPUT PARAMETERS AC Side Nominal AC Power fkWl 5000 6000 Max.AC Power k 5000 6000 AC Grid Connection single phase/split phase Nominal AC Voltage Range M Default:240V split phase Optional:208 or 277 single phase(setting required) Maximum AC Voltage Range M 187.2-224.6;216-259.2.249.3.299.2 Nominal AC Frequency Hz 60 Max.AC Line Current A 241,20-.18 30 short circuit 29;25;21.6 30 short circuit AC Side Varistor 2 Live-Neutral/Live-PE SCREW TERMINAL BLOCK AC Connection 3 KNOCK-OUTS:G1&1/2"or G1"(using ring reduction) CONDUCTOR CROSS SECTION: AWG4/8 Line Power Factor 1 AC Current Distortion(THD) <2%at rated ower with sine wave voltage Max.Efficiency 97% CEC Efficiency 96.5% Feed In Power Threshold DM 20 Ni t Time Consum tion BM <2 Isolation Transformer-less EHYNIONIMENTAL PARAMETERS Cooling Natural cooling Ambient Temp.Range "C -25/+60(output power deratina above 50°C Operating Altitude ft 6.000 Acoustical Noise LdBA <50 @ 1 mt Environmental IP Rating IP65 Relative Humidity 0-100%condensing MECHANICAL Dimensions HxWxD Inches 385 x1213/16"x711/16" Weight M 66 OTHER Di YES AI hanumedc 2 lines RS485(Spring terminal block-Conductor cross section:0,08-1,5mmq/AWG28-16) Communication USB connection(Service) "Aurora Eas -Control"s stem for remote control(Optional) Standards and Codes Aurora inverters comply with standards set for grid-tied operation,safety,and electromagnetic compatibility including:U1.1741/IEEE1547&CSA-022.2 N.107.1-01, VDE0126,CEI 11-20,DK5940,CEI64-8,IEC 61683,IEC 61727,EN50081,EN50082,EN61000,CE certification,EI Real Decreto RD1663/2000 de Espafia. ® AURORA Vcwbyg Photovoltaic Inverter g'the Shope of Power Block Diagram and Operating Configurations IBoor 1 , EMI Lie ti Md GFCI cost r Me Filhrl PLM GFCI pde- �� ' sons Inverter PV Array y ' Voc=600 V max. : 800shr OSP caihd Imniter 0r� -------- Vnom=360 V Microprocessor system controller LCD PE i I Inverter electrical block diagram ( I I ---------------------------------------------------------------- oC switch +PVInpu112 --«-0— � t MPPT 1ZDC/AC , -Pv1npe112 I i AC i +Pvinpur2.t I Output I I =PT PubtPur2.t i t l i PVI-5000-OUTO-S/PVI.6000-OUTC-5 j --------------------------------------------------------------------- I I I � I � I Rev.1.1 Juns.10,2009 .� Power-One Inc. 740 Calle Plano Camarillo,California-93012-8583 aesales-us®power-one.com www. power-one .com SURVEY OF LOT 101 S UBDI VISION MAP OF CEDAR BEACH PARK FILE No. 90 FILED DECEMBER 20. 1927 SITUATED AT BAYVIEW TOWN OF SOUTHOLD SUFFOLK COUNTY, NEW YORK S.C. TAX No. 1000-90-02-20 SCALE 1 !l=20! AUGUST 14, 2007 WAOA D DocK GA AREA = 26,344 sq. ft. (TO TIE LINE) 0.605 ac. /FL1a4TING If OOD DOCK CE 4 4Pnw '• • d �DAR ,a. O 1 �rT T - � d if ;41 -, •.d ASPHALT PAyEAIENT LLL// I V • ca a •. FOUND S 81 E EAS ' Q PIPE 0.6N. °4 . 5 0„ d • . • • �.• f . '• I • �. w I 'f 101 ,60! �P�oL� Q 3 • FOUND o I d • a :y MON. O.SCOENC. • f I d. • 4 I . .. • :. 300.0' CO • ; ' 'A: .. V Q0 f d• • I 44 • .• A 0� 0V .° N b �.• Ie • �- A• a •. / p A. •f .! a 4 A4 f o • ' r •• S 1, I d S w SSD WOOD DECK ' 4 • d . •.. ..a . ' • A. s WOOD DECK WOOD a !a w OIL STEPS • .A••' d FILL • • ..•a 14.6. Wool) DECK :• . a ; 4 UVU cHMNEE KDOD pE K TOTER .: CO 4 d INCE c NC. APRON y W 0.21W. 48.4' :'•:' ;. ":. DDD WALL �, N 8.5' BOE UNDER).. OOD \ UNI 1 & STEPS ase 2 STORY FRAME CHIMNEY �!�O HOUSE dr GARAGE N tE 12NEE ,�"ti c,►, O 18.0' Wz FEIN, E G? 13.8• W WOOD C. DECK CON �i 24.0' TO &S7 PS Y rd ENTRAWCE a 71' r7•�WOOD DECK ii 1Y Ol E: THIS PARCEL ALSO BEING KNOWN AS LOT 10 ON I �° 2 MAP No. 1 OF PART OF PROPERTY OF EDWIN H. BROWN �►�'°e5 0 FILE IN THE OFFICE OF THE CLERK OF SUFFOLK COUNTY ON JANUARY 27, 1926 AS FILE No. 802 I 8 a TOP OF SLOPE 3 w h w wO PIAT. CI I W D.EE SiED Z J MOOD a1LKHEAp k PREPARED IN ACCORDANCE WITH THE MINIMUM WOOD DECK w STANDARDS FOR TITLE SURVEYS AS ESTABLISHED Q BY THE L.I.A.L.S. AND APPROVED AND ADOPTED SANO BCH o FOR SUCH ON. THE NEW YORK STATE LAND TITLE_ ID BU OF til W N AHEAD PF T C rU N 7 u off, (O �t� �� °37! !! A LINE � � , ke A } �A 50 W WATER MARK ALONG AUGUST GH 0 �I � 101.08! H F� O OG c `�'J L1 N.Y.S. Lic. No.°50467 I p j,7lyO� K ^ UNAUTHORIZED ALTERATION ADDITION �� LA TO THIS SURVEY IS A VIOLATION OF Nathan Taft Corwin III 1 1. t L 1 SECTION 72OF THE NEW YORK STATE / EDUCATION LAW. COPIES THIS SURVEY MAP NOT BEARING Land Surveyor THE LANDD AL SURVEYOR'S INKED SEOR EMBOSSED SEAL SHALL NOT BE CONSIDERED TO BE A VALID TRUE COPY. CERTIFICATIONS INDICATED HEREON SHALL RUN ONLY TO THE PERSON FOR WHOM THE SURVEY IS PREPARED, AND ON HIS BEHALF TO THE Title Surveys — Subdivisions — Site Plans — Construction Layout TITLE COMPANY, GOVERNMENTAL AGENCY AND LENDING INSTITUTION LISTED HEREON, AND TO THE ASSIGNEES OF THE LENDING INSTI- PHONE (631)727-2090 Fax (631)727-1727 TUITION. CERTIFICATIONS ARE NOT TRANSFERABLE. OFFICES LOCATED AT MAILING ADDRESS THE EXISTENCE OF RIGHTS OF WAY 322 ROANOKE AVENUE P.O. Box 1931 AND/OR EASEMENTS OF RECORD, IF ANY, NOT SHOWN ARE NOT GUARANTEED. RIVERHEAD, New York 11901 Riverhead, New York 11901-0965