Loading...
HomeMy WebLinkAboutGenerator for Landfill Town Hall, 53095 Main Road -:. P.O. Box 1179 Southold, New York 11971 JUDITH T.TERRY "' d TELEFAX PHONE(765-1823 TOWN CLERK 16)765-1801 REGISTRAR OF VITAL STATISTICS OFFICE OF THE TOWN CLERK TOWN OF SOUTHOLD January 30, 1990 John C. Mihoulides, Vice President Nestor Associates Inc. Atrium Executive Center 80 Orville Drive Bohemia, New York 11716 Dear Mr. Mihoulides: Superintendent of Highways Jacobs has advised me that the Emergency General System for the landfill has been delivered and is acceptable. I am, therefore, returning your $100.00 bid deposit check herewith. Very truly yours, Judith T. Terr Y Southold Town Clerk Enclosure �" n# Town Hall, 53095 Main Road P.O. Box 1179 Southold, New York 11971 JUDITH T.TERRY - x =' FAX(516)765-1823 TOWN CLERK TELEPHONE(516)765-1801 REGISTRAR OF VITAL STATISTICS OFFICE OF THE TOWN CLERK TOWN OF SOUTHOLD November 20, 1989 John C. Mihoulides Vice President Nestor Associates Inc. Atrium Executive Center 80 Orville Drive Bohemia, New York 11716 Dear Mr. Mihoulides: This is to correct my letter of June 12, 1989 to you concerning the Emergency Generator System at the Southold Town Landfill Site. The Southold Town Board, at their regular meeting held on June 6, 1989, accepted your bid in the amount of $12,995.00 for the delivery of the Emergency Generator System, all in accordance with the bid specifications. The word "installation" was used in error. Please contact Superintendent of Highways Jacobs at 765-3140 concerning the delivery date. Very truly yours, Judith T. Terry Southold Town Clerk cc: Supt. of Hwys. Jacobs FAX COVER SHEET TO: John C. Mihoulides, President, Nestor Associates Inc. (Fax #567-0611) FROM: Judith T. Terry, Southold Town Clerk DATE: November 20, 1989 Pages to follow: 1 Additional Comments: IF ALL PACES ARE NOT RECEIVED, PLEASE CALL SOUTHOLD TOWN HALL at (516) 765-1800 •rte,-.,;��, ti Town Hall, 53095 Main Road w�,� `. ► o,�-; P.O. Box 1179 �j Southold, New York 11971 JUDITH T.TERRY ', , `` FAX(516)765-1823 TOWN CLERK TELEPHONE(516)765-1801 REGISTRAR OF VITAL STATISTICS OFFICE OF THE TOWN CLERK TOWN OF SOUTHOLD June 12, 1989 John C. Mihoulides Vice President Nestor Associates Inc. Atrium Executive Center 80 Orville Drive Bohemia, New York 11716 Dear Mr. Mihoulides: The Southold Town Board, at their regular meeting held on June 6, 1989, accepted your bid in the amount of $12, 995-00 for the +wstal+e#far> of an Emergency Generator System at the Southold Town Landfill Site, Cutchogue, all in accordance with the bid specifications. Once the project has been completed your $100.00 bid deposit check will be returned to you. Please contact Superintendent of Highways Raymond L. Jacobs (765- 3140) for further instructions concerning the project.- Very truly yours, Judith T. Terry Southold Town Clerk cc: Supt. of Hwys. Jacobs r1 Town Hall, 53095 Main Road �.„ ► P.O. Box 1179 > n1 `�� Southold, New York 11971 JUDITH T.TERRY FAX(516)765-1823 TOWN CLERK TELEPHONE(516)765-1801 REGISTRAR OF VITAL STATISTICS OFFICE OF THE TOWN CLERK TOWN OF SOUTHOLD June 12, 1989 Frank Scavelli Vice President E General Manager Suffolk Lighting S Electrical Supply, Inc. 550 East Main Street Riverhead, New York 11901 Dear Mr. Scavelli : The Southold Town Board, at their regular meeting held on June 6, 1989, accepted the bid f le Associates, Inc. , in the amount of $12,995.00, for the of an Emergency Generator System at the Southold Town Landfill Site, Cutchogue. Returned herewith is your $100. 00 bid deposit check. Thank you for submitting a bid for this project.- Very truly yours, Judith T. Terry Southold Town Clerk o Town Hall, 53095 Main Road P.O. Box 1179 Southold, New York 11971 JUDITH T.TERRY 1 FAX(516)765-1823 TOWN CLERK TELEPHONE(516)765-1801 REGISTRAR OF VITAL STATISTICS OFFICE OF THE TOWN CLERK TOWN OF SOUTHOLD THIS IS TO CERTIFY THAT THE FOLLOWING RESOLUTION WAS ADOPTED BY THE SOUTHOLD TOWN BOARD AT A REGULAR MEETING HELD ON JUNE 6, 1989: RESOLVED that the Town Board of the Town of Southold hereby accepts the bid of Nestor Associates, Inc. , in the amount of $12,995. 00, for the of an Emergency Generator System at the Southold Town Land- fill Site, Cutchogue; said bid all in accordance with the bid specifications. Judith T. Terry Southold Town Clerk June 9, 1989 ELECTRICAL SUPPLY, WC, 550 EAST MAIN STREET,RIVERHEAD,NEW YORK 11901 PHONE:727-1155•SOUTHAMPTON 283-4800 May 16, 1989 Town of Southold Southold Town Hall Main Street Southold, New York 11971 Attention: Southold Town Clerk Reference: Bid on Emergency Generator Madam/Sir: We bid the following per your specifications, with exception to Section 2, Article 3.7. Please delete the first two sentences as indicated. The Town of Southold will provide necessary equipment to unload generator from delivery truck. Price: F.O.B. Job Site, Southold, N.Y. - $14,919.00 Terms: Less 2%, 10 days - net 15 days. Respectfully submitted, 7FK LIGHTING & ELECTRICAL SUPPLY, INC. 'S Frank Scavelli Vice President & General Manager FS/pl Enclosures Suffolk Lighting...An Illumitiating Experience a LEGAL NOTICE NOTICE TO BIDDERS NOTICE IS HEREBY GIVEN in accordance with the provisions of Section 103 of the General Municipal Law, sealed bids are sought and requested for the purchase of an Emergency Generator System for the Southold Town Landfill. Specifications may be obtained at the Office of the Town Clerk, Town of Southold, Town Hall, Main Road, Southold, New York 11971. The sealed bids, together with a Non-Collusive Certificate and bank draft or certified check in the amount of $100.00 will be received by the Town Clerk of the Town of Southold, at the Southold Town Hall, Main Road, Southold, New York, until 11 :00 A.M. , Thursday, May 25, 1989, at which time they will be opened and read aloud in public. The Town Board of the Town of Southold reserves the right to reject any and all bids and waive any and all informality in any bid should it be deemed in the best interest of the Town of Southold to do so. All bids must be signed and sealed in envelopes plainly marked "Bid on Emergency Generator System", and submitted to the Office of the Town Clerk. The bid price shall not include any tax, federal, state or local., from which the Town of Southold is exempt. DATED : May 5, 1989. JUDITH T. TEIY `n SOUTHOLD TOWN` E�K,U PLEASE PUBLISH ONCE, MAY 11 , 1989, AND FORWARD ONE (1) AFFIDAVIT OF PUBLICATION TO JUDITH T. TERRY, TOWN CLERK, TOWN HALL, MAIN ROAD , SOUTHOLD , NEW YORK 11971. Copies to the following : The Suffolk Times y ' The Long Island Traveler-Watchman , Town Board members e ; Commissioner of Public Works Jacobs Dodge Reports Town Clerk's Bulletin Board r; RECOMMENDED SAMPLE SPECIFICATIONS DYNAMAXX 50 KW DIESEL OR EQUAL SECTION 1 - GENERAL REQUIREMENTS 1.1 GENERAL DESCRIPTION - THIS SPECIFICATION DEFINES THE REQUIRE- MENTS FOR AN EMERGENCY/STAND-BY ELECTRIC POWER SUPPLY SYSTEM (EPSS) TO BE INSTALLED IN THE TOWN OF SOUTHOLD LANDFILL IN ACCORDANCE WITH THE ARCHITECTS PLANS FOR THE STRUCTURE. THE EPSS SHALL CONSIST OF AN ENGINE/GENERATOR SET THAT IS CAPABLE OF MEETING THE ELECTRICAL REQUIREMENTS DEFINED IN SECTION 1.2 FOR THE DURATION OF A FAILURE OF THE NORMAL POWER SUPPLY. THE ENGINE/GENERATOR SET SHALL CONSIST OF A DIESEL CYCLE ENGINE DIRECTLY COUPLED TO A SYNCHRONOUS A.C. GENERATOR WITH A SYSTEM FOR AUTOMATICALLY CONTROLLING THE COMBINATION IN A SAFE AND RELIABLE MANNER. 1.2 ELECTRICAL REQUIREMENTS - THE EPSS SHALL BE CAPABLE OF PRO- VIDING 120/208 VOLTS, 3 PHASE, 4 WIRE, 60 HZ ELECTRICAL POWER. IT SHALL BE CAPABLE OF PROVIDING UP TO 50 KW, 62.5 KVA, 0.8 P.F. FOR THE DURATION OF A TYPICAL POWER FAILURE WHICH EXPER- IENCE INDICATES IS LESS THAN 10 HOURS. 1.3 ENVIRONMENTAL CONDITIONS - THE EMERGENCY POWER SOURCE IS TO BE INSTALLED OUTDOORS WITHIN A WEATHER PROTECTIVE ENCLOSURE WITH LOCKING DOORS TO PROHIBIT UNAUTHORIZED ACCESS. THE AMBIENT OPERATING TEMPERATURE RANGE WILL BE 0 TO 100 DEGREES F. AND THE HUMIDITY RANGE WILL BE 10 TO 100%. THE INTENDED SITE IS LOCATED AT AN ELEVATION OF 62 FEET ABOVE SEA LEVEL. ERS RECOMMENDATIONS AND THE REQUIREMENTS OF NATIONALLY RECOG- NIZED STANDARDS AND LOCAL CODES AS APPLICABLE. SECTION 2 - ENGINE GENERATOR SET 2.1 QUALITY AND EXPERIENCE - THE ENGINE GENERATOR SET SHALL BE OF A STANDARD DESIGN THAT IS BUILT, TESTED, AND SHIPPED BY THE MANUFACTURER OF THE ALTERNATOR, WHO HAS BEEN ENGAGED PRIMARILY IN THE MANUFACTURER OF ENGINE GENERATOR SETS AND ASSOCIATED CONTROLS FOR A MINIMUM OF 10 YEARS TO INSURE PARTS AND SERVICE SUPPORT FROM A COMMON SOURCE. THE MANUFACTURER SHALL SUPPLY PRINTED MATERIALS/BROCHURES DESCRIBING THE SThNDARD CON�IG- URATION BEING OFFERED. THE MANUFACTURER SHALL FURNISH COMPLETE SCHEMATIC AND WIRING DIAGRAMS FOR THE ENGINE/GENERATOR SET INCLUDING INTERCONNECT POINTS FOR THE OTHER COMPONENTS OF THE SYSTEM. THE MANUFACTURER SHALL HAVE PROTOTYPE TESTED THE THE ENGINE GENERATOR SET IN ACCORDANCE WITH ACCEPTED PRACTICES AND THE APPLICAB6 REQUIREMENTS OF RECOGNIZED STANDARDS ORGAN- IZATIONS (NEMA, IEEE. SAE, EGSA, CSA, UL) . ALL EQUIPMENT AND COMPONENTS SUPPLIED SHALL BE NEW AND OF THE LATEST DESIGN AND SHALL BE COVERED BY THE MANUFACTURERS STANDARD COMMERCIAL WARRANTY. 2.2 WARRANTY - THE MANUFACTURER SHALL WARRANT THE ENGINE GENERATOR SET FOR A PERIOD OF ONE YEAR FROM DATE OF COMMENCEMENT OF OPERATION. A COPY OF THE WARRANTY STATING COMPLETE TERMS AND CONDITIONS WILL BE PROVIDED. 2.3 OPERATION AND MAINTENANCE INFORMATION - THE MANUFACTURER WILL,, PROVIDE COMPLETE OPERATION, MAINTENANCE, AND PARTS MANUALS COVERING ALL COMPONENTS OF THE ENGINE GENERATOR SET SYSTEM. SECTION 3 - ENGINE REQUIREMENTS 3.1 THE BASIC ENGINE SHALL BE OF A STANDARD DESIGN AND MANUFACTURE AS DESCRIBED IN SECTION 3.2 ADDITIONALLY, IT WILL BE FITTED WITH A GOVERNOR SYSTEM FOR SPEED REGULATION, A COOLING SYSTEM, AN ELECTRICAL STARTING SYSTEM, AN EXHAUST SYSTEM, A FUEL SUPPLY SYSTEM, AND MISCELLANEOUS ACCESSORIES AS DESCRIBED IN SECTIONS 3.3 THROUGH 3.8. 3.2 THE BASIC ENGINE REQUIREMENTS/SPECIFICATIONS ARE AS FOLLOWS; *GENERAL DESCRIPTION - THE ENGINE SHALL BE A LIQUID-COOLED, 4-CYCLE, DIESEL TYPE, 4 CYLINDER IN-LINE DESIGN, TURBO- CHARGED, WITH DIRECT FUEL INJECTION. -MANUFACTURER/MODEL NO. : CUMMINS 4BT3.9 *BORE/STROKE/DISPLACEMENT: 4.02 IN./4.72 IN./2.39 CU. IN. *BHP/@ 1800 RPM: 82 BHP MIN. *COMPRESSION RATIO: 17.5 to 1 *LUBRICATION SYSTEM DESCRIPTION - ROTARY GEAR DRIVEN POSITIVE DISPLACEMENT PUMP TO PROVIDE FULL PRESSURE LUBRICATION , A FULL FLOW OIL FILTER, AND 11.6 QUART CAPACITY. *FUEL SYSTEM DESCRIPTION - LUCAS CAV FUEL PUMP SYSTEM (MAX. LIFT 5 FT.) AND DIRECT FUEL INJECTION. *AIR INTAKE SYSTEM - DRY ELEMENT TYPE AIR CLEANER. *COOLANT PUMP - CENTRIFUGAL, BELT-DRIVEN. 3.3 GOVERNOR SYSTEM - THE ENGINE SHALL BE FITTED WITH A MECHANICAL DROOP-TYPE GOVERNOR THAT IS CAPABLE MAINTAINING ENGINE SPEED WITHIN THE FOLLOWING SPECIFICATIONS: *STEADY STATE STABILITY: +1-0.5% MAXIMUM N.L. TO F.L. *FREQUENCY REGULATION: 4.0% DROOP F.L. TO N.L. THE GOVERNOR SHALL BE FITTED WITH A MEANS OF MECHANICALLY AD- JUSTING ENGINE SPEED AND AN AUTOMATIC OVERSPEED SHUTDOWN MECHANISM TO PREVENT ENGINE DAMAGE. 3.4 COOLING SYSTEM - THE ENGINE SHALL BE FITTED WITH A UNIT-MOUNTED COOLING SYSTEM CONSISTING OF A THERMOSTATICALLY CONTROLLED RADIATOR AND ENCLOSED PUSHER-TYPE BELT DRIVEN FAN. A THERM- OSTATICALLY CONTROLLED CIRCULATION TYPE ENGINE PREHEATER RATED AT 1000 WATTS/120 V.A.C. WILL BE PROVIDED TO MAINTAIN ENGINE COOLANT TEMPERATURE BETWEEN 100 AND 120 DEGREES F. DURING PERIODS OF NON-OPERATION. 3.5 ENGINE ELECTRICAL START SYSTEM - THE ENGINE SHALL BE FITTED WITH AN ELECTRICAL STARTING SYSTEM CONSISTING OF A BATTERY, AN ALTERNATOR FOR CHARGING THE BATTERY DURING ENGINE OPERATION, AN ELECTRIC STARTER MOTOR, AND AN AUXILIARY BATTERY CHARGER SUPPLIED BY THE NORMAL POWER SOURCE TO CHARGE AND MAINTAIN THE BATTERY WHEN THEOENGINE IS NOT OPERATING. THE SYSTEM AND COMPONENTS SHALL COMPLY WITH THE FOLLOWING SPECIFICATIONS. *GENERAL SYSTEM SPECIFICATION - 12 V.D.C. NEGATIVE GROUND *BATTERY REQUIREMENTS - THE BATTERY SHALL BE LEAD-ACID TYPE OF SUFFICIENT CAPACITY TO PROVIDE 2 COMPLETE ENGINE CRANK PERIODS UNDER THE MOST SEVERE CONDITIONS ANTICIPATED. IT SHALL HAVE A MINIMUM CAPACITY OF 85 AH AND 650 CCA. *ENGINE ALTERNATOR - A 61 AMP BELT-DRIVEN ALTERNATOR WITH AN AUTOMATIC VOLTAGE REGULATOR TO CHARGE AND MAINTAIN THE BATTERY DURING ENGINE OPERATION SHALL BE PROVIDED. *ELECTRIC STARTER - A HEAVY DUTY 12 VOLT STARTER MOTOR ACT- UATED BY A POSITIVE ENGAGEMENT SOLENOID SHALL BE PROVIDED. IT MUST BE CAPABLE OF CRANKING THE ENGINE AT THE RECOMMENDED SPEED FOR A COMPLETE CRANKING CYCLE WITHOUT OVERHEATING UNDER THE MOST SEVERE CONDITIONS ACTICIPATED. *AUXILIARY BATTERY CHARGER - A CONVENTIONAL BATTERY CHARGER SUPPLIED BY THE NORMAL POWER SOURCE SHALL BE PROVIDED. IT SHALL BE CAPABLE OF RECHARGING THE BATTERY FROM A FULLY DISCHARGED STATE WITHIN 36 HOURS WITHOUT DAMAGE. IT SHALL BE CAPABLE OF MAINTAINING THE BATTERY IN A FULL STATE OF CHARGE WITHOUT DAMAGE. IT WILL INCLUDE THE FOLLOWING FEATURES: * REGULATED SEMI-FLOAT TYPE DESIGN * 12 V.D.C./5 AMP RATED OUTPUT * 120 V.A.C./60 HZ RATED INPUT * D.C. FUSE AND A.C. CIRCUIT BREAKER * CHARGE RATE AMMETER * LOW VOLTAGE SHUTDOWN FOR REVERSE POLARITY AND SHORT CIRCUIT PHOTECTION * CRANKING DISCONNECT RELAY 3.6 EXHAUST SYSTEM REQUIREMENTS - A FLEXIBLE STAINLESS STEEL EXHAUST CONNECTOR AT LEAST 18 INCHES IN LENGTH AND A CRIT- ICAL GRADE SILENCER OF PROPER SIZE AND DESIGN SHALL BE PROVIDED TO CONNECT INTO A CONTRACTOR INSTALLED EXHAUST PIPING SYSTEM OF APPROVED DESIGN. 3.7 FUEL SUPPLY SYSTEM - A. FUEL SUPPLY SYSTEM CONSISTING OF A MAIN FUEL STORAGE TANK ADD A DAY TANK SYSTEM. THE MAIN STORAGE TANK SYSTEM, INCLUDING TANK, FITTINGS, PIPING, AND GUAGES WILL BE SUPPLIED AND INSTALLED BY THE BUILDING CONTRACTOR IN ACCORDANCE WITH SPECIFICATIONS THAT COMPLY ` ' WITH NATIONALLY RECOGNIZED STANDARDS AND LOCAL CODES AS APPLICABLE. A 25 GALLON DAY TANK SYSTEM CAPABLE OF SUPPLYING FUEL TO THE ENGINE FOR A MINIMUM OF 6# HOURS OF OPERATION AT FULL RATED LOAD SHALL BE PROVIDED. THE DAY TANK SYSTEM WILL BE INSTALLED IN CLOSE PROXIMITY TO THE ENGINE GENERATOR SET AND SHALL INCLUDE THE FniLOWING FEATURES: *HEAVY GAUGE STEEL TANK WITH EPDXY COATED INSIDE AND RUSTPROOF AND PAINTED OUTSIDE SURFACE TREATMENT. *INPUT/OUTPUT FUEL SUPPLY AND RETURN CONNECTIONS. *TANK VENT AND DRAIN CONNECTIONS. *1/3 HP, 120 V.A.C. , 60 HZ MOTOR AND BRONZE GEAR PUMP WITH ADJUSTABLE FLOAT SWITCH FOR TRANSFER FROM MAIN STORAGE TANK. *CONTROL PANEL WITH FUEL GAUGE, PUMP RUNNING LIGHT, AND PUSH-TO-TEST SWITCH. *INPUT CHECK VALVE AND FUEL FILTER 3.8 ACCESSORIES - REFER TO ACCESSORY/OPTIONAL EQUIPMENT LIST SECTION 4 - GENERATOR SYSTEM 4.1 GENERAL DESCRIPTION - THE GENERATING SYSTEM SHALL CONSIST OF A SYNCHRONOUS, BRUSHLESS A.C. GENERATOR/EXCITER, A VOLTAGE REG- ULATOR, AND A PROTECTIVE HOUSING FOR INTERNAL AND EXTERNAL CONNECTIONS. THE GENERATOR AND ASSOCIATED COMPONENTS SHALL BE IN COMPLIANCE WITH NEMA, IEEE, AND OTHER APPLICABLE STANDARDS FOR THIS TYPE OF EQUIPMENT. 4.2 GENERATOR REQUIREMENTS - THE GENERATOR SHALL BE A BRUSHLESS, BROAD-RANGE RECONNECTABLE (12 LEAD) , 4-POLE (SALIENT TYPE) ROTATING FIELD, 3-PHASE SYNCHRONOUS A.C. GENERATOR. THE STATOR COIL WINDING AXIS SHALL BE SKEWED FOR IMPROVED WAVEFORM, THE ROTATING FIELD SHALL HAVE AMORTISSEUR TYPE WINDING BARS FOR IMPROVED WAVEFORM AND TRANSIENT RESPONSE, REDUCED HEATING WITH SINGLE PHASE OR UNBALANCED 3-PHASE LOADS, AND PARALLELING CAPABILITY. THE GENERATOR SHALL BE DYNAMICALLY BALANCED IN BOTH THE DIRECT AND QUADRATURE AXIS AND SHALL BE CONNECTED AND PERMANENTLY ALIGNED TO THE ENGINE BY A FLEXIBLE DISC-TYPE COUPLING. THE GENERATOR SHALL BE OF A DRIP-PROOF DESIGN WITH AN INTEGRAL DIRECT-DRIVE CENTRIFUGAL COOLING FAN. 4.3 GENERATOR SPECIFICATIONS - THE GENERATOR SHALL MEET OR EXCEED THE FOLLOWING MINIMUM DESIGN AND PERFORMANCE SPECIFICATIONS: "COIL VOLTAGE RANGE - 120 TO 139 VOLTS *RECONNECTION VOLTAGE RANGE - 120 TO 480 VOLTS *INSULATION TYPE/PROCESS - STATOR: VARNISH, DOUBLE DIP AND BAKE. ROTOR: 100% THIXOTROPIC EPDXY, VACUUM IMPREGNATED. *TEMPERATURE RISE - WITHIN CLASS F LIMITS AS DEFINED BY NEMA MG1-22.40 AT RATED LOAD AND POWER FACTOR. *WAVEFORM DEVIATION FACTOR - 5% MAXIMUM (L-L AND I-N/N.L. ) PER NEMA MG1-22.42 *TOTAL HARMONIC DISTORTION - 3.0% MAXIMUM (L-L/F.L. , 0.8 P.F. WYE CONNECTED) *MAXIMUM SINGLE HARMONIC - 2.5% MAXIMUM (L-L/F.L. , 0.8 P.F. , WYE CONNECTED) *TELEPHONE INFLUENCE FACTOR (TIF) - LESS THAN 50 * EFFICIENCY @ FULL LOAD - 89% MINIMUM * VOLTAGE DIP - LESS THAN 35% @ 250% OF RATED KVA 4.4 EXCITER REQUIREMENTS - POWER TO THE ROTATING GENERATOR FIELD WILL BE PROVIDED BY A BRUSHLESS EXCITER ALTERNATOR. THE EX- SITER SHALL CONSIST OF A 16 POLE LUNDELL-TYPE EXCITER FIELD STATOR AND A 3-PHASE EXCITER ROTOR INCORPORATING A FULL WAVE ROTATING RECTIFIER ASSEMBLY WITH A SURGE SUPPRESSOR TO PRO- TECT THE RECTIFIER DIODES. THE EXCITER SYSTEM SHALL BE MOUNTED OUTBOARD I�F THE GENERATOR BEARING/SUPPORF SYSTEM TO PROVIDE DIRECT ACCESS FOR INSPECTION AND SERVICE. 4.5 VOLTAGE REGULATOR REQUIREMENTS - AN AUTOMATIC SOLID STATE (STATIC) VOLTAGE REGULATOR TO MONITOR GENERATOR OUTPUT CONDITIONS AND PROVIDE EXCITATION POWER TO THE EXCITER FIELD AS REQUIRED SHALL BE PROVIDED. THE REGULATOR SHALL INCORPORATE FREQUENCY COMPENSATION (VOLTS/HERTZ) TO IMPROVE MOTOR STARTING CAPABILITY AND PROHIBIT ENGINE STALL UNDER OVERLOAD CONDITIONS. THE VOLTAGE REGULATOR SHALL HAVE A COMMON PROTECTED SENSE AND POWER INPUT FROM THE GENERATOR. THE REGULATOR SHALL INCORPOR- ATE EM1 FILTERING OF THE OUTPUT, OVEREXCITATION PROTECTION, AND A SOLID STATE VOLTAGE BUILD UP CIRCUIT TO ALLOW A RAPID START UP WHILE PROHIBITING EXCESSIVE OVERSHOOT. THE REGULATOR MUST HAVE A QUADRATURE DROOP INPUT TERMINAL CONNECTION TO ALLOW PARALLEL OPERATION IF REQUIRED. THE VOLTAGE REGULATOR SHALL HAVE THE FOLLOWING ADJUSTMENT CAPABILITIES: * INTERNAL VOLTAGE ADJUSTMENT * EXTERNAL VOLTAGE ADJUSTMENT (+1-10%, REMOTE RHEOSTAT) * UNDERSPEED FREQUENCY * RESPONSE STABILITY 4.6 ENGINE/GENERATOR SET PERFORMANCE - THE COMBINATION OF ENGINE/ GENERATOR/VOLTAGE REGULATOR SHALL BE CAPABLE OF CONTROLLING THE GENERATOR OUTPUT WITHIN THE FOLLOWING SPECIFICATIONS: * STEADY-STATE REGULATION - +1-0.5% (N.L. TO F.L.) * TRANSIENT DIP (N.L. TO F.L.) - 13.5% MAX./L.B.O. * TRANSIENT 0/S (F.L. TO N.L.) - 14% MAX./L.B.O. * RECOVERY TO STABLE REGULATION - 0.5 SECONDS MAXIMUM * MOTOR STARTING CAPABILITY - 20 HP, CODE F(116 SKVA, 480 V. , 60 HZ) , 28.0% VOLTAGE DIP 4.7 PROTECTIVE HOUSING REQUIREMENTS - A PROTECTIVE HOUSING FOR THE GENERATOR/EXCITER, VOLTAGE REGULATOR, AND POWER RECONNECTION AND OUTPUT TERMINALS SHALL BE PROVIDED. THE GENERATOR LEADS SHALL BE SECURELY ATTACHED TO.AN INSULATED BOARD AND RECONNEC- TION SHALL BE ACCOMPLISHED BY ATTACHING SOLID COPPER LINK BARS TO THE COIL LEAD ATTACHMENTS ACCORDING TO THE PATTERN SPECIFIED ON THE HOUSING PANEL TO PROVIDE WYE OR DELTA, HIGH OR LOW VOLT- AGE, AND SINGLE OR THREE PHASE CONNECTION. INSULATED STAND-OFFS WILL BE PROVIDED ON AN INSULATED BOARD FOR THE SAFE AND CONVEN- IENT CONNECTION OF THE POWER LEADS AND NEUTRAL TERMINAL. 4.8 ACCESSORIES - A MAINLINE CIRCUIT BREAKER TO PROTECT THE GENERATOR FROM SUSTAINED OVERLOAD CONDITIONS AND/OR LOW POWER FACTOR LOADS WILL BE PROVIDED. A CURRENT BOOST SYSTEM TO SUSTAIN POWER OUTPUT FOR CLEARING PROTECTIVE DEVICES UNDER FAULTED CONDITIONS AND AIDING HEAVY MOTOR LOADS WITH HIGH START UP TORQUE REQUIRE- MENTS WILL BE PROVIDED. SECTION 5 - AUTOMATIC CONTROL SYSTEM 5.1 AUTOMATIC SAFETY SHUTDOWN CONTROL - THE CONTROL SYSTEM SHALL BE ABLE TO TERMINATE OPERATION OF THE ENGINE/GENERATOR SET SHOULD ANY OF THE FOLLOWING UNSAFE OR HAZARDOUS CONDITIONS EXIST: ENGINE OVERSPEED * LOW ENGINE OIL PRESSURE * HIGH ENGINE COOLANT TEMPERATURE * LOW ENGINE COOLANT LEVEL 5.2 MANUAL OPERATIONAL CONTROLS - THE CONTROL CABINET SHALL HAVE THE FOLLOWING OPFWATOR CONTROL COMPONENTS: * MODE OF OPERATION SELECTOR - OFF/MANUAL * GENERATOR OUTPUT VOLTAGE ADJUSTMENT (+1-10%) * EMERGENCY STOP SWITCH - LIGHTED * METER/PANEL LIGHT SWITCH - ON/OFF * MANUALLY SWITCHABLE GENERATOR FIELD CIRCUIT BREAKER * MANUALLY SWITCHABLE CONTROL PANEL CIRCUIT BREAKER * METER/PANEL/ANNUNCIATOR LAMP TEST SWITCH - PUSH TO TEST * BYPASS SWITCH (TO MANUALLY OVERRIDE SHUTDOWNS) - LIGHTED 5.3 INSTRUMENTATION/ANNUNCIATION - THE CONTROL CABINET SHALL INCORPORATE THE FOLLOWING POWER METERING EQUIPMENT, ENGINE GUAGES, AND STATUS ANNUNCIATOR LIGHTS WITH DUAL LAMPS: A. POWER METERING GROUP * A.C. VOLTMETER - DUAL SCALE, 2.0% ACCURACY * A.C. AMMETER - DUAL SCALE, 2.0% ACCURACY * FREQUENCY METER - 45 TO 65 HZ, 0.5% ACCURACY * PHASE SELECTOR SWITCH WITH OFF POSITION * HIGH/LOW METER SCALE INDICATOR LIGHT B. ENGINE GAUGE GROUP * COOLANT TEMPERATURE - DEGREES F AND C * OIL PRESSURE - PSI AND KP/CM2 * D.C. VOLTMETER (ENGINE ELECTRICAL START SYSTEM) * RUNNING TIME METER - 0.1 HOURS • NON-COLLUSIVE BID CERTIFICATE The undersigned bidder certifies that this bid has been arrived at by the bidder independently and has been submitted without collusion with any other vendor of materials, supplies or equipment of the type described in the invitation for bids, and the contents of this bid have not been communicated by the bidder, nor, to its best knowledge and belief, by any of its employees or agents, to any person not an employee or agent of the bidder or its surety on any bond furnished herewith prior to the official opening of the bid. r (Signed) (Corporate Title) (if any) a � Bid on EMERGENCY GENERATOR SYSTEM Nestor Associates, Inc. Atrium Executive Center • 80 Orville Drive • Bohemia, N.Y. 11716 QUOTE NO. 89-1621 MAY 22 , 1989 ATTENTION:JUDITH T. TERRY REFERENCE: EMERGENCY GENERATOR SYSTEM-SOUTHOLD LANDFILL MADAM WE ARE PLEASED TO SUBMIT OUR QUOTATION ON THE ABOVE REFERENCED PROJECT AS FOLLOWS: ONE 55 KW DETROIT DIESEL GENERATING SET, (RADIATOR COOLED) MODEL F04.39303, RATED FOR EMERGENCY POWER AT 55 KW, 208 VOLTS, 3 PHASE 4 WIRE, 60 HERTZ, . 80 POWER FACTOR WITH ACCESSORIES AS HEREIN INDICATED. ( ) FUEL AND LUBRICATING OIL FILTERS ( ) AIR CLEANERS- DRY TYPE ( ) GOVERNOR -WOODWARD ( ) ENGINE JACKET WATER HEATER ( ) CIRCUIT BREAKER ( ) AUTO SHUT DOWN- LOW OIL - ( ) AUTO SHUT DOWN- HI. WATER TEMP. ( ) AUTO SHUT DOWN- ENGINE OVERSPEED ( ) TRICKLE BATTERY CHARGER ( ) BATTERIES (LEAD ACID) ( ) BATTERY RACK AND CABLE ( ) SILENCER (CRITICAL) ( ) FLEX. EXHAUST ( ) FUEL DAY TANK (CAPACITY 25 GALS. ) (FREE STANDING) (HI-LOW LEVEL ALARM) ( ) CONTROL PANEL NEMA 1 (UNIT)MOUNTED ( ) VIBRATION ISOLATORS ( ) SHIPPING (516) 563-1837 • (516) 665-6070 Telex: 697-3500 HPGEXCTR 9 Fax: (516) 267-0611 Nestor Associates, Inc. ( ) FACTORY TESTS(RESISTIVE) ( ) WARRANTY (ONE YEAR) ( ) START UP www.w.ww.wwwwwwwwwwwwEXCEPTIONSwwwwwww.w.ww.w.w.w.ww* FUEL STORAGE TANK TO BE INSTALLED AND PIPED TO GENERATOR DAY TANKS BY OTHERS DAY TANK SPECIFIED WILL NOT CONTAIN SUFFICIENT FUEL TO OPERATE GENERATOR FOR 64 HOURS. +wwwrwwwwwww rwwwwwy w.rwww,r;rwwwwww r,r,rwv.wxy.v.wwww ALL OF THE ABOVE NET--$12, 995. 00 DELIVERY WILL BE MADE BY TRUCK, CURBSIDE. CUSTOMER TO PROVIDE UNLOADING FACILITIES AND LABOR. UNLOADING TIME NOT TO EXCEED TWO (2)HOURS FROM TIME OF ARRIVAL ON JOBSITE TERMS: - TO BE DISCUSSED PRICE IS FIRM FOR 30 DAYS. WE ARE NOT RESPONSIBLE FOR SECURING AND PAYING FEES FOR PERMITS, LICENSES, CERTIFICATES, INSPECTIONS, REGISTRATIONS AND THE LIKE REQUIRED BY ANY GOVERNMENT OR REGULATORY AGENCY AND REQUIRED IN ANY WAY FOR THE INSTALLATION AND OPERATION OF THE ABOVE QUOTED EQUIPMENT DELIVERY: APPROXIMATELY 16 WEEKS AFTER RECEIPT OF APPROVAL TO PROCEED WITH FABRICATION. THANK YOU FOR THE OPPORTUNITY TO SUBMIT OUR QUOTATION. IF YOU HAVE ANY QUESTIONS OR WOULD LIKE ANY FURTHER INFORMATION, PLEASE CONTACT THE UNDERSIGNED. VERY T ULY YOURS arm ��, JOHN C. MI OULIDES VICE PRESIDENT NESTOR ASSOCIATES INC. FAX 516 567-0611 TOWN OF SOUT4CiLT 1 Y • NON-COLLUSIVE BID CERTIFICATE The undersigned bidder certifies that this bid has been arrived at by the bidder independently and has been submitted without collusion with any other- vendor of materials, supplies or equipment of the type rJescribed in the invitation for bids, and the contents of this bid have not been communicated by the bidder, nor, to its best knowledge and belief, by any of its employees or agents, to any person not an employee or agent of the bidder or its surety on any bond furnished herewith prior to the official opening of the bid. S ( igned) orporate Title) Bid on LMERGENCY&GLNERATOR SYSTEM r ,: BIDS - EMERGENCY GENERATOR SYSTEM Bid Opening: 11 :00 A.M. , Thursday, May 25, 1989 1• Suffolk Lighting Supply, Riverhead, N.Y. 2. Mayfair Power Systems Inc. , 9 Niagara Rd,Freeport, NY 11520 Attn: Paul Eberst 3. Heating and Piping, Specialties Corp. , P.O. Box 477, Laurel, NY 11948 4. Nestor Assoc. , 80 Orville Dr., Bohemia, N.Y. 11716 563-1837 FAX 567-0611 Attention : John Mihoulides 5• LEB Electric, Ralph Ave. , Lindenhurst, N.Y. 842-0500 Attn: Vincent Brett LEGAL NOTICE NOTICE TO BIDDERS NOTICE IS HEREBY GIVEN n, accordance with the provisiond of STATE OF NEW YORK) Section 103 of the General Municipal Law, sealed bids are sought and re- )SS: quested for the purchase of an Emer- COUNTY OF SUFFOLK) gency Generator System for the Southold Town Landfill.Specifica- tions may be obtained at the Officemof Ch r i s t i n a C o n t e n t o -the Town Clerk,Town of Southold, of Mattituek, in Town Hall, Main Road, Southold, said County,being duly sworn,says that he/she is Principal New York 11971. The sealed bids,together with a Clerk of THE SUFFOLK TIMES, a Weekly Newspaper, Non-Collusive Certificate and bank published at Mattituek, In the Town of Southold, County of draft or certified check in the amount of$100.00 will be received by the Suffolk and State of New York,and that the Notice of which Town Clerk of the Town of the annexed Is a printed copy,has been regularly published in Southold,at the Southold Town Ball, Main Road, Southold, New York, said Newspaper once each week for 1 weeks until 11:00 A.M.,Thursday,May 35, successively, commencing on the __11 day of 1989, at which time they will be opened and Head aloud in public.The May 19$� Town Board of the Town of Southold reserves the right to reject any and all bids and waive any and all informality .in any bid should it be deemed in the best interest of the Town of Southold ' to do so. All bids must be signed and sealed Principal Clerk in envelopes plainly marked"Bid on Emergency Generator System",and submitted to the Office of the Town Clerk.The bid Price shall not include any tax,federal,state or local,from Sworn to bef rrle this which the Town of Southold is ex- empt. day of 19 MARY K.DEGNAN DATED:May 5,1989. TARP P!,?(iC,State of New York IUDrFH T.TERRY S„folk''our; r ';o.4,349860 SOUTHOLDTOWNCLERK Term Expires l-e ruar 9�� 6290-1TMyll CJ I is COUNTY OF SUFFOLK ss: STATE OF NEW YORK LEGAL NOTICE NOTICE TO BIDDERS NOTICE .IS HEREBY Patricia Wood, being duly sworn, says that she is the GIVEN in accordance with the Editor, of THE LONG ISLAND TRAVELER-WATCHMAN, provisions of Section 103 of the General Municipal Law, sealed a public newspaper printed at Southold, in Suffolk County; bids are sought and requested and that the notice of which the annexed is a printed copy, for the purchase an Emer- gency has been published in said Lon Island Traveler-Watchman Generator System for the p g Southold Town Landfill.Speci- once each week for . . . . . . . . . . . . . . . . . . . . . . . . . . . weeks fications may be obtained at the Office of the Town Clerk,Town of Southold, Town Hall,.Main successively, commencing on the . . . . . . . . . . . . . . . . . . . . . . Road, Southold, New York 11971. da of �` The sealed bids,together with Y 9 a Non-Collusive Certificate and --- bank draft or certified check in -- ; _rte; the amount of$100.00 will be re- " " " " " " ceived by the Town Clerk of the Town of Southold, at the,, Southold Town Hall, Main Road,Southold, New York,un- U til 11:00 A.M., Thursday, May Sworn to before me this . . . . . . . . . . . ��. . . . . . . . day of 25, 1989,at which time they will be opened and read aloud in �- public. The Town Board of the . . . . . . � . . • . . • • • . . . 19 . !7 j Town of Southold reserves the right to reject any and all bids and waive any and all informali- ty in any,bid should it be deem- ed in the best interest of the t town of Southold to do so. " " " " " " " " " ' " " " " ' " " All bids must be signed and Notary Public sealed in envelopes plainly marked "Bid on Emergency ` r� SCHNEIDER : 'v ' Generator System, and submit- ' "', State of New York ted to the Office of the Town r` t'3 f( ; Clerk.The bid price shall not in- clude County any tax, federal, state or local, from which the Town of Southold is exempt. DATED: May 51' 1989 JUDITH T. TERRY SOUTHOLD TOWN CLERK 1X.5/11/89(31) I' II Ij i f STATE OF NEW YORK) SS: COUNTY OF SUFFOLK) JUDITH T. TERRY, Town Clerk of the Town of Southold, New York, being duly sworn, says that on the 5th day of May 1989 she affixed a notice of which the annexed printed notice is 'a true copy, in a proper and substantial manner, in a most public place in the Town of Southold, Suffolk County, New York, to wit: Town Clerk's Bulletin Board, Southold Town Hall, Main Road, Southold, New York 11971. Legal Notice, Notice to Bidders: Emergency Generator System for the Landfill. Bid opening: 11 :00 A.M. , May 25, 1989, Southold Town Hall. Judith T. Terry Southold Town Clerk Sworn to before me this 5th day of May 19 89 14 Notary Publi ELIZABETH ANN NEVILLE Notary Public,State of New York No.52-8125850,Suffolk Coqqty Term Expires October 31, 19 !f • f i l� I LEGAL NOTICE ti NOTICE TO BIDDERS i NOTICE IS HEREBY GIVEN in accordance with the provisions of Section 103 of the General Municipal Law, sealed bids are sought and requested for the purchase of an Emergency Generator System for the Southold Town Landfill, Specifications may be obtained at the Office of the Town Clerk, Town of !� Southold, Town Hall, Main Road, Southold, New York 11971. The sealed bids, together with a Non-Collusive Certificate and bank draft or certified check in the amount of $100.00 will be received by the Town Clerk of the Town of Southold, at the Southold Town Hall, Main Road, I Southold, New York, until 11 :00 A.M. , Thursday, May 25, 1989, at which time they will be opened and read aloud in public. The Town Board of the Town of Southold reserves the right to reject any and all bids and waive any and all informality in any bid should it be deemed in the best interest of the Town of Southold to do so. i, All bids must be signed and sealed in envelopes plainly marked "Bid on Emergency Generator System", and submitted to the Office of the Town Clerk. li The bid price shall not include any tax, federal, state or local., from which I the Town of Southold is exempt. DATED : May 5, 1989. JUDITH T. TERRY ( SOUTHOLD TOWN CLERK I PLEASE PUBLISH ONCE, MAY 11, 1989, AND FORWARD ONE (1) AFFIDAVIT OF PUBLICATION TO JUDITH T. TERRY, TOWN CLERK, TOWN HALL, MAIN ROAD , SOUTHOLD , NEW YORK 11971. Copies to the following : i The Suffolk Times The Long Island Traveler-Watchman Town Board members Commissioner of Public Works Jacobs Dodge Reports Town Clerk's Bulletin Board i f 1 I; i • 0 RECOMMENDED SAMPLE SPECIFICATIONS DYNAMAXX 50 KW DIESEL OR EQUAL SECTION 1 - GENERAL REQUIREMENTS 1.1 GENERAL DESCRIPTION - THIS SPECIFICATION DEFINES THE REQUIRE- MENTS FOR AN EMERGENCY/STAND-BY ELECTRIC POWER SUPPLY SYSTEM (EPSS) TO BE INSTALLED IN THE TOWN OF SOUTHOLD LANDFILL IN ACCORDANCE WITH THE ARCHITECTS PLANS FOR THE STRUCTURE. THE EPSS SHALL CONSIST OF AN ENGINE/GENERATOR SET THAT IS CAPABLE OF MEETING THE ELECTRICAL REQUIREMENTS DEFINED IN SECTION 1.2 FOR THE DURATION OF A FAILURE OF THE NORMAL POWER SUPPLY. THE ENGINE/GENERATOR SET SHALL CONSIST OF A DIESEL CYCLE ENGINE DIRECTLY COUPLED TO A SYNCHRONOUS A.C. GENERATOR WITH A SYSTEM FOR AUTOMATICALLY CONTROLLING THE COMBINATION IN A SAFE AND RELIABLE MANNER. 1.2 ELECTRICAL REQUIREMENTS - THE EPSS SHALL BE CAPABLE OF PRO- VIDING 120/208 VOLTS, 3 PHASE, 4 WIRE, 60 HZ ELECTRICAL POWER. IT SHALL BE CAPABLE OF PROVIDING UP TO 50 KW, 62.5 KVA, 0.8 P.F. FOR THE DURATION OF A TYPICAL POWER FAILURE WHICH EXPER- IENCE INDICATES IS LESS THAN 10 HOURS. 1.3 ENVIRONMENTAL CONDITIONS - THE EMERGENCY POWER SOURCE IS TO BE INSTALLED OUTDOORS WITHIN A WEATHER PROTECTIVE ENCLOSURE WITH LOCKING DOORS TO PROHIBIT UNAUTHORIZED ACCESS. THE AMBIENT OPERATING TEMPERATURE RANGE WILL BE 0 TO 100 DEGREES F. AND THE HUMIDITY RANGE WILL BE 10 TO 100%. THE INTENDED SITE IS LOCATED AT AN ELEVATION OF 62 FEET ABOVE SEA LEVEL. ERS RECOMMENDATIONS AND THE REQUIREMENTS OF NATIONALLY RECOG- NIZED STANDARDS AND LOCAL CODES AS APPLICABLE. SECTION 2 - ENGINE GENERATOR SET 2.1 QUALITY AND EXPERIENCE - THE ENGINE GENERATOR SET SHALL BE OF A STANDARD DESIGN THAT IS BUILT, TESTED, AND SHIPPED BY THE MANUFACTURER OF THE ALTERNATOR, WHO HAS BEEN ENGAGED PRIMARILY IN THE MANUFACTURER OF ENGINE GENERATOR SETS AND ASSOCIATED CONTROLS FOR A MINIMUM OF 10 YEARS TO INSURE PARTS AND SERVICE SUPPORT FROM A COMMON SOURCE. THE MANUFACTURER SHALL SUPPLY PRINTED MATERIALS/BROCHURES DESCRIBING THE STANDARD CONFIG- URATION BEING OFFERED. THE MANUFACTURER SHALL FURNISH COMPLETE SCHEMATIC AND WIRING DIAGRAMS FOR THE ENGINE/GENERATOR SET INCLUDING INTERCONNECT POINTS FOR THE OTHER COMPONENTS OF THE SYSTEM. THE MANUFACTURER SHALL HAVE PROTOTYPE TESTED THE THE ENGINE GENERATOR SET IN ACCORDANCE WITH ACCEPTED PRACTICES AND THE APPLICABLE REQUIREMENTS OF RECOGNIZED STANDARDS ORGAN- IZATIONS (NEMA, IEEE. SAE, EGSA, CSA, UL) . ALL EQUIPMENT AND COMPONENTS SUPPLIED SHALL BE NEW AND OF THE LATEST DESIGN AND SHALL BE COVERED BY THE MANUFACTURERS STANDARD COMMERCIAL WARRANTY. 2.2 WARRANTY - THE MANUFACTURER SHALL WARRANT THE ENGINE GENERATOR SET FOR A PERIOD OF ONE YEAR FROM DATE OF COMMENCEMENT OF OPERATION. A COPY OF THE WARRANTY STATING COMPLETE TERMS AND CONDITIONS WILL BE PROVIDED. 2.3 OPERATION AND MAINTENANCE INFORMATION - THE MANUFACTURER WILL PROVIDE COMPLETE OPERATION, MAINTENANCE, AND PARTS MANUALS COVERING ALL COMPONENTS OF THE ENGINE GENERATOR SET SYSTEM. 0 SECTION 3 - ENGINE REQUIREMENTS 3.1 THE BASIC ENGINE SHALL BE OF A STANDARD DESIGN AND MANUFACTURE AS DESCRIBED IN SECTION 3.2 ADDITIONALLY, IT WILL BE FITTED WITH A GOVERNOR SYSTEM FOR SPEED REGULATION, A COOLING SYSTEM, AN ELECTRICAL STARTING SYSTEM, AN EXHAUST SYSTEM, A FUEL SUPPLY SYSTEM, AND MISCELLANEOUS ACCESSORIES AS DESCRIBED IN SECTIONS 3.3 THROUGH 3.8. 3.2 THE BASIC ENGINE REQUIREMENTS/SPECIFICATIONS ARE AS FOLLOWS; *GENERAL DESCRIPTION - THE ENGINE SHALL BE A LIQUID-COOLED, 4-CYCLE, DIESEL TYPE, 4 CYLINDER IN-LINE DESIGN, TURBO- CHARGED, WITH DIRECT FUEL INJECTION. *MANUFACTURER/MODEL NO. : CUMMINS 4BT3.9 *BORE/STROKE/DISPLACEMENT: 4.02 IN./4.72 IN./2.39 CU. IN. *BHP/@ 1800 RPM: 82 BHP MIN. *COMPRESSION RATIO: 17.5 to 1 *LUBRICATION SYSTEM DESCRIPTION - ROTARY GEAR DRIVEN POSITIVE DISPLACEMENT PUMP TO PROVIDE FULL PRESSURE LUBRICATION , A FULL FLOW OIL FILTER, AND 11.6 QUART CAPACITY. *FUEL SYSTEM DESCRIPTION - LUCAS CAV FUEL PUMP SYSTEM (MAX. LIFT 5 FT.) AND DIRECT FUEL INJECTION. *AIR INTAKE SYSTEM - DRY ELEMENT TYPE AIR CLEANER. *COOLANT PUMP - CENTRIFUGAL, BELT-DRIVEN. 3.3 GOVERNOR SYSTEM - THE ENGINE SHALL BE FITTED WITH A MECHANICAL DROOP-TYPE GOVERNOR THAT IS CAPABLE MAINTAINING ENGINE SPEED WITHIN THE FOLLOWING SPECIFICATIONS: *STEADY STATE STABILITY: +1-0.5% MAXIMUM N.L. TO F.L. *FREQUENCY REGULATION: 4.0% DROOP F.L. TO N.L. THE GOVERNOR SHALL BE FITTED WITH A MEANS OF MECHANICALLY AD- JUSTING ENGINE SPEED AND AN AUTOMATIC OVERSPEED SHUTDOWN MECHANISM TO PREVENT ENGINE DAMAGE. 3.4 COOLING SYSTEM - THE ENGINE SHALL BE FITTED WITH A UNIT-MOUNTED COOLING SYSTEM CONSISTING OF A THERMOSTATICALLY CONTROLLED RADIATOR AND ENCLOSED PUSHER-TYPE BELT DRIVEN FAN. A THERM- OSTATICALLY CONTROLLED CIRCULATION TYPE ENGINE PREHEATER RATED AT 1000 WATTS/120 V.A.C. WILL BE PROVIDED TO MAINTAIN ENGINE COOLANT TEMPERATURE BETWEEN 100 AND 120 DEGREES F. DURING PERIODS OF NON-OPERATION. 3.5 ENGINE ELECTRICAL START SYSTEM - THE ENGINE SHALL BE FITTED WITH AN ELECTRICAL STARTING SYSTEM CONSISTING OF A BATTERY, AN ALTERNATOR FOR CHARGING THE BATTERY DURING ENGINE OPERATION, AN ELECTRIC STARTER MOTOR, AND AN AUXILIARY BATTERY CHARGER SUPPLIED BY THE NORMAL POWER SOURCE TO CHARGE AND MAINTAIN THE BATTERY WHEN THE ENGINE IS NOT OPERATING. THE SYSTEM AND COMPONENTS SHALL COMPLY WITH THE FOLLOWING SPECIFICATIONS. *GENERAL SYSTEM SPECIFICATION - 12 V.D.C. NEGATIVE GROUND *BATTERY REQUIREMENTS - THE BATTERY SHALL BE LEAD-ACID TYPE OF SUFFICIENT CAPACITY TO PROVIDE 2 COMPLETE ENGINE CRANK PERIODS UNDER THE MOST SEVERE CONDITIONS ANTICIPATED. IT SHALL HAVE A MINIMUM CAPACITY OF 85 AH AND 650 CCA. *ENGINE ALTERNATOR - A 61 AMP BELT-DRIVEN ALTERNATOR WITH AN AUTOMATIC VOLTAGE REGULATOR TO CHARGE AND MAINTAIN THE BATTERY DURING ENGINE OPERATION SHALL BE PROVIDED. 0 *ELECTRIC STARTER - A HEAVY DUTY 12 VOLT STARTER MOTOR ACT- UATED BY A POSITIVE ENGAGEMENT SOLENOID SHALL BE PROVIDED. IT MUST BE CAPABLE OF CRANKING THE ENGINE AT THE RECOMMENDED SPEED FOR A COMPLETE CRANKING CYCLE WITHOUT OVERHEATING UNDER THE MOST SEVERE CONDITIONS ACTICIPATED. *AUXILIARY BATTERY CHARGER - A CONVENTIONAL BATTERY CHARGER SUPPLIED BY THE NORMAL POWER SOURCE SHALL BE PROVIDED. IT SHALL BE CAPABLE OF RECHARGING THE BATTERY FROM A FULLY DISCHARGED STATE WITHIN 36 HOURS WITHOUT DAMAGE. IT SHALL BE CAPABLE OF MAINTAINING THE BATTERY IN A FULL STATE OF CHARGE WITHOUT DAMAGE. IT WILL INCLUDE THE FOLLOWING FEATURES: * REGULATED SEMI-FLOAT TYPE DESIGN * 12 V.D.C./5 AMP RATED OUTPUT * 120 V.A.C./60 HZ RATED INPUT * D.C. FUSE AND A.C. CIRCUIT BREAKER * CHARGE RATE AMMETER * LOW VOLTAGE SHUTDOWN FOR REVERSE POLARITY AND SHORT CIRCUIT PHOTECTION * CRANKING DISCONNECT RELAY 3.6 EXHAUST SYSTEM REQUIREMENTS - A FLEXIBLE STAINLESS STEEL EXHAUST CONNECTOR AT LEAST 18 INCHES IN LENGTH AND A CRIT- ICAL GRADE SILENCER OF PROPER SIZE AND DESIGN SHALL BE PROVIDED TO CONNECT INTO A CONTRACTOR INSTALLED EXHAUST PIPING SYSTEM OF APPROVED DESIGN. 3.7 FUEL SUPPLY SYSTEM - A FUEL SUPPLY SYSTEM CONSISTING OF A MAIN FUEL STORAGE TANK AND A DAY TANK SYSTEM. THE MAIN STORAGE TANK SYSTEM, INCLUDING TANK, FITTINGS, PIPING, AND GUAGES WILL BE SUPPLIED AND INSTALLED BY THE BUILDING CONTRACTOR IN ACCORDANCE WITH SPECIFICATIONS THAT COMPLY WITH NATIONALLY RECOGNIZED STANDARDS AND LOCAL CODES AS APPLICABLE. A 25 GALLON DAY TANK SYSTEM CAPABLE OF SUPPLYING FUEL TO THE ENGINE FOR A MINIMUM OF 64 HOURS OF OPERATION AT FULL RATED LOAD SHALL BE PROVIDED. THE DAY TANK SYSTEM WILL BE INSTALLED IN CLOSE PROXIMITY TO THE ENGINE GENERATOR SET AND SHALL INCLUDE THE FOLLOWING FEATURES: *HEAVY GAUGE STEEL TANK WITH EPDXY COATED INSIDE AND RUSTPROOF AND PAINTED OUTSIDE SURFACE TREATMENT. *INPUT/OUTPUT FUEL SUPPLY AND RETURN CONNECTIONS. *TANK VENT AND DRAIN CONNECTIONS. *1/3 HP, 120 V.A.C. , 60 HZ MOTOR AND BRONZE GEAR PUMP WITH ADJUSTABLE FLOAT SWITCH FOR TRANSFER FROM MAIN STORAGE TANK. *CONTROL PANEL WITH FUEL GAUGE, PUMP RUNNING LIGHT, AND PUSH-TO-TEST SWITCH. *INPUT CHECK VALVE AND FUEL FILTER 3.8 ACCESSORIES - REFER TO ACCESSORY/OPTIONAL EQUIPMENT LIST SECTION 4 - GENERATOR SYSTEM 4.1 GENERAL DESCRIPTION - THE GENERATING SYSTEM SHALL CONSIST OF A SYNCHRONOUS, BRUSHLESS A.C. GENERATOR/EXCITER, A VOLTAGE REG- ULATOR, AND A PROTECTIVE HOUSING FOR INTERNAL AND EXTERNAL CONNECTIONS. THE GENERATOR AND ASSOCIATED COMPONENTS SHALL BE IN COMPLIANCE WITH NEMA, IEEE, AND OTHER APPLICABLE STANDARDS FOR THIS TYPE OF EQUIPMENT. 4.2 GENERATOR REQUIREMENTS - THE GENERATOR SHALL BE A BRUSHLESS, BROAD-RANGE RECONNECTABLE (12 LEAD) , 4-POLE (SALIENT TYPE) ROTATING FIELD, 3-PHASE SYNCHRONOUS A.C. GENERATOR. THE STATOR COIL WINDING AXIS SHALL BE SKEWED FOR IMPROVED WAVEFORM, THE ROTATING FIELD SHALL HAVE AMORTISSEUR TYPE WINDING BARS FOR IMPROVED WAVEFORM AND TRANSIENT RESPONSE, REDUCED HEATING WITH SINGLE PHASE OR UNBALANCED 3-PHASE LOADS, AND PARALLELING CAPABILITY. THE GENERATOR SHALL BE DYNAMICALLY BALANCED IN BOTH THE DIRECT AND QUADRATURE AXIS AND SHALL BE CONNECTED AND PERMANENTLY ALIGNED TO THE ENGINE BY A FLEXIBLE DISC-TYPE COUPLING. THE GENERATOR SHALL BE OF A DRIP-PROOF DESIGN WITH AN INTEGRAL DIRECT-DRIVE CENTRIFUGAL COOLING FAN. 4.3 GENERATOR SPECIFICATIONS - THE GENERATOR SHALL MEET OR EXCEED THE FOLLOWING MINIMUM DESIGN AND PERFORMANCE SPECIFICATIONS: *COIL VOLTAGE RANGE - 120 TO 139 VOLTS *RECONNECTION VOLTAGE RANGE - 120 TO 480 VOLTS *INSULATION TYPE/PROCESS - STATOR: VARNISH, DOUBLE DIP AND BAKE. ROTOR: 100% THIXOTROPIC EPDXY, VACUUM IMPREGNATED. *TEMPERATURE RISE - WITHIN CLASS F LIMITS AS DEFINED BY NEMA MG1-22.40 AT RATED LOAD AND POWER FACTOR. *WAVEFORM DEVIATION FACTOR - 5% MAXIMUM (L-L AND I-N/N.L. ) PER NEMA MG1-22.42 *TOTAL HARMONIC DISTORTION - 3.0% MAXIMUM (L-L/F.L. , 0.8 P.F. WYE CONNECTED) *MAXIMUM SINGLE HARMONIC - 2.5% MAXIMUM (L-L/F.L. , 0.8 P.F. , WYE CONNECTED) *TELEPHONE INFLUENCE FACTOR (TIF) - LESS THAN 50 * EFFICIENCY @ FULL LOAD - 89% MINIMUM * VOLTAGE DIP - LESS THAN 35% C 250% OF RATED KVA 4.4 EXCITER REQUIREMENTS - POWER TO THE ROTATING GENERATOR FIELD WILL BE PROVIDED BY A BRUSHLESS EXCITER ALTERNATOR. THE EX- SITER SHALL CONSIST OF A 16 POLE LUNDELL-TYPE EXCITER FIELD STATOR AND A 3-PHASE EXCITER ROTOR INCORPORATING A FULL WAVE ROTATING RECTIFIER ASSEMBLY WITH A SURGE SUPPRESSOR TO PRO- TECT THE RECTIFIER DIODES. THE EXCITER SYSTEM SHALL BE MOUNTED OUTBOARD OF THE GENERATOR BEARING/SUPPORT- SYSTEM TO PROVIDE DIRECT ACCESS FOR INSPECTION AND SERVICE. 4.5 VOLTAGE REGULATOR REQUIREMENTS - AN AUTOMATIC SOLID STATE (STATIC) VOLTAGE REGULATOR TO MONITOR GENERATOR OUTPUT CONDITIONS AND PROVIDE EXCITATION POWER TO THE EXCITER FIELD AS REQUIRED SHALL BE PROVIDED. THE REGULATOR SHALL INCORPORATE FREQUENCY COMPENSATION (VOLTS/HERTZ) TO IMPROVE MOTOR STARTING CAPABILITY AND PROHIBIT ENGINE STALL UNDER OVERLOAD CONDITIONS. THE VOLTAGE REGULATOR SHALL HAVE A COMMON PROTECTED SENSE AND POWER INPUT FROM THE GENERATOR. THE REGULATOR SHALL INCORPOR- ATE EM1 FILTERING OF THE OUTPUT, OVEREXCITATION PROTECTION, AND A SOLID STATE VOLTAGE BUILD UP CIRCUIT TO ALLOW A RAPID START UP WHILE PROHIBITING EXCESSIVE OVERSHOOT. THE REGULATOR MUST HAVE A QUADRATURE DROOP INPUT TERMINAL CONNECTION TO ALLOW PARALLEL OPERATION IF REQUIRED. THE VOLTAGE REGULATOR SHALL HAVE THE FOLLOWING ADJUSTMENT CAPABILITIES: * INTERNAL VOLTAGE ADJUSTMENT * EXTERNAL VOLTAGE ADJUSTMENT (+1-10%, REMOTE RHEOSTAT) * UNDERSPEED FREQUENCY * RESPONSE STABILITY 4.6 ENGINE/GENERATOR SET PERFORMANCE - THE COMBINATION OF ENGINE/ GENERATOR/VOLTAGE REGULATOR SHALL BE CAPABLE OF CONTROLLING THE GENERATOR OUTPUT WITHIN THE FOLLOWING SPECIFICATIONS: * STEADY-STATE REGULATION - +1-0.5% (N.L. TO F.L. ) * TRANSIENT DIP (N.L. TO F.L.) - 13.5% MAX./L.B.O. * TRANSIENT 0/S (F.L. TO N.L.) - 14% MAX./L.B.O. * RECOVERY TO STABLE REGULATION - 0.5 SECONDS MAXIMUM * MOTOR STARTING CAPABILITY - 20 HP, CODE F(116 SKVA, 480 V. , 60 HZ) , 28.0% VOLTAGE DIP 4.7 PROTECTIVE HOUSING REQUIREMENTS - A PROTECTIVE HOUSING FOR THE GENERATOR/EXCITER, VOLTAGE REGULATOR, AND POWER RECONNECTION AND OUTPUT TERMINALS SHALL BE PROVIDED. THE GENERATOR LEADS SHALL BE SECURELY ATTACHED TO AN INSULATED BOARD AND RECONNEC- TION SHALL BE ACCOMPLISHED BY ATTACHING SOLID COPPER LINK BARS TO THE COIL LEAD ATTACHMENTS ACCORDING TO THE PATTERN SPECIFIED ON THE HOUSING PANEL TO PROVIDE WYE OR DELTA, HIGH OR LOW VOLT- AGE, AND SINGLE OR THREE PHASE CONNECTION. INSULATED STAND-OFFS WILL BE PROVIDED ON AN INSULATED BOARD FOR THE SAFE AND CONVEN- IENT CONNECTION OF THE POWER LEADS AND NEUTRAL TERMINAL. 4.8 ACCESSORIES - A MAINLINE CIRCUIT BREAKER TO PROTECT THE GENERATOR FROM SUSTAINED OVERLOAD CONDITIONS AND/OR LOW POWER FACTOR LOADS WILL BE PROVIDED. A CURRENT BOOST SYSTEM TO SUSTAIN POWER OUTPUT FOR CLEARING PROTECTIVE DEVICES UNDER FAULTED CONDITIONS AND AIDING HEAVY MOTOR LOADS WITH HIGH START UP TORQUE REQUIRE- MENTS WILL BE PROVIDED. SECTION 5 - AUTOMATIC CONTROL SYSTEM 5.1 AUTOMATIC SAFETY SHUTDOWN CONTROL - THE CONTROL SYSTEM SHALL BE ABLE TO TERMINATE OPERATION OF THE ENGINE/GENERATOR SET SHOULD ANY OF THE FOLLOWING UNSAFE OR HAZARDOUS CONDITIONS EXIST: * ENGINE OVERSPEED * LOW ENGINE OIL PRESSURE * HIGH ENGINE COOLANT TEMPERATURE * LOW ENGINE COOLANT LEVEL 5.2 MANUAL OPERATIONAL CONTROLS - THE CONTROL CABINET SHALL HAVE THE FOLLOWING OPERATOR CONTROL COMPONENTS: * MODE OF OPERATION SELECTOR - OFF/MANUAL * GENERATOR OUTPUT VOLTAGE ADJUSTMENT (+1-10%) * EMERGENCY STOP SWITCH - LIGHTED * METER/PANEL LIGHT SWITCH - ON/OFF * MANUALLY SWITCHABLE GENERATOR FIELD CIRCUIT BREAKER * MANUALLY SWITCHABLE CONTROL PANEL CIRCUIT BREAKER * METER/PANEL/ANNUNCIATOR LAMP TEST SWITCH - PUSH TO TEST * BYPASS SWITCH (TO MANUALLY OVERRIDE SHUTDOWNS) - LIGHTED 5.3 INSTRUMENTATION/ANNUNCIATION - THE CONTROL CABINET SHALL INCORPORATE THE FOLLOWING POWER METERING EQUIPMENT, ENGINE GUAGES, AND STATUS ANNUNCIATOR LIGHTS WITH DUAL LAMPS: A. POWER METERING GROUP * A.C. VOLTMETER - DUAL SCALE, 2.0% ACCURACY * A.C. AMMETER - DUAL SCALE, 2.0% ACCURACY * FREQUENCY METER - 45 TO 65 HZ, 0.5% ACCURACY * PHASE SELECTOR SWITCH WITH OFF POSITION * HIGH/LOW METER SCALE INDICATOR LIGHT B. ENGINE GAUGE GROUP * COOLANT TEMPERATURE - DEGREES F AND C * OIL PRESSURE - PSI AND KP/CM2 * D.C. VOLTMETER (ENGINE ELECTRICAL START SYSTEM) * RUNNING TIME METER - 0.1 HOURS NON-COLLUSIVE BID CERTIFICATE The undersigned bidder certifies that this bid has been arrived at by the bidder independently and has been submitted without collusion with any other vendor of materials, supplies or equipment of the type described in the invitation for bids, and the contents of this bid have not been communicated by the bidder, nor, to its best knowledge and belief, by any of its employees or agents, to any person not an employee or agent of the bidder or its surety on any bond furnished herewith prior to the official opening of the bid. (Signed) (Corporate Title) (if any) Bid on EMERGENCY GENERATOR SYSTEM LEGAL NOTICE NOTICE TO BIDDERS NOTICE IS HEREBY GIVEN in accordance with the provisions of Section 103 of the General Municipal Law, sealed bids are sought and requested for the purchase of an Emergency Generator System for the Southold Town Landfill. Specifications may be obtained at the Office of the Town Clerk, Town of Southold, Town Hall, Main Road, Southold, New York 11971. The sealed birds, together with a Non-Collusive Certificate and bank draft or certified check in the amount of $100.00 will be received by the Town Clerk of the Town of Southold, at the Southold Town Hall, Main Road, Southold, New York, until 11 :00 A.M. , Thursday, May 25, 1989, at which time they will be opened and read aloud in public. The Town Board of the Town of Southold reserves the right to reject any and all bids and waive any and all informality in any bid should it be deemed in the best interest of the Town of Southold to do so. All bids must be signed and sealed in envelopes plainly marked "Bid on Emergency Generator System", and submitted to the Office of the Town Clerk. The bid price shall not include any tax, federal, state or local., from which the Town of Southold is exempt. DATED : May 5, 1989. JUDITH T. TERRY SOUTHOLD TOWN CLERK PLEASE PUBLISH ONCE, MAY 11, 1989, AND FORWARD ONE (1) AFFIDAVIT' OF PUBLICATION TO JUDITH T. TERRY, TOWN CLERK, TOWN HALL, MAIN ROAD, SOUTHOLD, NEW YORK 11971. Copies to the following : The Suffolk Times -_ The Long Island Traveler-Watchman Town Board members Commissioner of Public Works Jacobs Dodge Reports Town Clerk's Bulletin Board • LEGAL NOTICE NOTICE TO BIDDERS NOTICE IS HEREBY GIVEN in accordance with the provisions of Section 103 of the General Municipal Law, sealed bids are sought and requested for the purchase of an Emergency Generator System for the Southold Town Landfill. Specifications may be obtained at the Office of the Town Clerk, Town of Southold, Town Hall, Main Road, Southold, New York 11971. The sealed bids, together with a Non-Collusive Certificate and bank draft or certified check in the amount of $100.00 will be received by the Town Clerk of the Town of Southold, at the Southold Town Haid, Main Road, Southold, New York, until 11 :00 A.M. , Thursday, May 25, 1989, at which time they will be opened and read aloud in public. The Town Board of the Town of Southold reserves the right to reject any and all bids and waive any and all informality in any bid should it be deemed in the best interest of the Town of Southold to do so. All bids must be signed and sealed in envelopes plainly marked "Bid on Emergency Generator System", and submitted to the Office of the Town Clerk. The bid price shall not include any tax, federal, state or local., from which the Town of Southold is exempt. DATED : May 5, 1989. JUDITH T. TERRY SOUTHOLD TOWN CLERK PLEASE PUBLISH ONCE, MAY 11, 1989, AND FORWARD ONE (1) AFFIDAVIT' OF PUBLICATION TO JUDITH T. TERRY, TOWN CLERK, TOWN HALL, MAIN ROAD , SOUTHOLD , NEW YORK 11971. Copies to the following : The Suffolk Times The Long Island Traveler-Watchman Town Board members Commissioner of Public Works Jacobs Dodge Reports Town Clerk's Bulletin Board • o��FF our�D� o Town Hall, 53095 Main Road �� • �- P.O. Box 1179 Southold, New York 11971 JUDITH T.TERRY 1 FAX(516)765-1823 TOWN CLERK TELEPHONE(516)765-1801 REGISTRAR OF VITAL STATISTICS OFFICE OF THE TOWN CLERK TOWN OF SOUTHOLD THIS IS TO CERTIFY THAT THE FOLLOWING RESOLUTION WAS ADOPTED BY THE SOUTHOLD TOWN BOARD AT A REGULAR MEETING HELD ON DECEMBER 13, 1988: RESOLVED that the Town Board of the Town of Southold hereby authorizes and directs the Town Clerk to advertise for bids for an emergency generator for the Landfill. d ���� dit T. erry Southold Town Cler December 14, 1988