Loading...
HomeMy WebLinkAbout38816-Z FOL Town of Southold Annex 6/5/2014 P.O.Box 1179 + 54375 Main Road 1W Southold, New York 11971 { fit CERTIFICATE OF OCCUPANCY No: 36957 Date: 6/5/2014 THIS CERTIFIES that the building GENERATOR Location of Property: 1205 Route 25, Greenport, SCTM#: 473889 Sec/Block/Lot: 35.-1-25 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this officed dated 4/17/2014 pursuant to which Building Permit No. 38816 dated 4/25/2014 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: ACCESSORY GENERATOR AS APPLIED FOR- COTTAGE#29 The certificate is issued to Peconic Lndng @ Southold (OWNER) of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 38816 06-02-2014 PLUMBERS CERTIFICATION DATED Authorized Signature 10FOl TOWN OF SOUTHOLD Al BUILDING DEPARTMENT ' TOWN CLERK'S OFFICE SOUTHOLD, NY {4 BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 38816 Date: 4/25/2014 Permission is hereby granted to: Peconic Lndng @ Southold 1500 Brecknock Rd Greenport, NY 11944 To: Installation of a generator as applied for- Cottage #29 At premises located at: 1205 Route 25, Greenport SCTM # 473889 Sec/Block/Lot# 35.-1-25 Pursuant to application dated 4/17/2014 and approved by the Building Inspector. To expire on 10/25/2015. Fees: ACCESSORY $100.00 CO -ACCESSORY BUILDING $50.00 Total: $150.00 i' Building Inspector Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings,property lines,streets,and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal (S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of i%lead. 5. Commercial building, industrial building,multiple residences and similar buildings and installations,a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings(prior to April 9, 1957)non-conforming uses,or buildings and"pre-existing" land uses: 1. Accurate survey of property showing all property lines,streets,building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant.If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00,Alterations to dwelling$50.00, Swimming pool$50.00,Accessory building$50.00,Additions to accessory building$50.00,Businesses$50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy-$.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy-Residential $15.00,Commercial$15.00 / Date. 2v v New Construction: Old or Pre-existing Building: (check one) Location of Property: J Z© _ d � Z 1 _ h House No. Street amlet Owner or Owners of Property: � C C C- C� Suffolk County Tax Map No 1000, Section Block Lot Subdivision GQ'( Filed Map. Lot: Permit No. 0 U ISD Date of Permit. Applicant: Health Dept. Approval: Underwriters Approval: Planning Board Approval: / Request for: Temporary Certificate Final Certificate: ✓ (check one) Fee Submitted: $ Applicant Sig ture SOUTyolo Town Hall Annex Telephone(631)765-1802 54375 Main Road C-11Fax(631)765-9502 P.O.Box 1179 G �� roger.riche rt(CD-town.Southold.ny.us Southold,NY 11971-0959 'QlyCOUNT'1,� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION Issued To: Peconic Landing (Marilyn Sahner) Address: 1205 Rt 25 Greenport--(29 Oriole Ln) City: St: Zip: Building Permit#: 38816 Section: 35 Block: 1 Lot: 25 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: Shore Power Electrical License No: 42536-me SITE DETAILS Office Use Only Residential X Indoor Basement Service Only Commerical Outdoor X 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures HID Fixtures Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Fluorescent Fixture Pumps Transformer Appliances Dryer Recpt Emergency Fixtures Time Clocks Disconnect Switches 11 Twist Lock Exit Fixtures TVSS Other Equipment: 14KW standby generator with 200a auto transfer switch Notes: Inspector Signature: Date: June 2 2014 81-Cert Electrical Compliance Form.xls FIELD INSPE • N ORT DATE coma ENTS C19 EOUND,piTION(1ST) � wMwwwwT+wMPwTwwwwwwww�ww�Nww . 45 y FOUNDATION(ZND) Cl LA rA C, ROUGH FACT& T , PLUMBING n INSULATION PER N.Y. y STATE ENERGY CODE . y FINAL ADDITION CONIlVlE cn K TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD,NY 11971 4 sets of Building Plans TEL: (631) 765-1802 Planning Board approval FAX: (631) 765-9502 Survey SoutholdTown.NorthFork.net PERMIT NO. I�� Check Septic Form N.Y.S.D.E.C. Trustees Flood Permit Examined ,20 Storm-Water Assessment Form 21 Contact: Approved ,20 Mail to: Disapproved a/c Phone: Expiration ,20 Bui mg Ins ctor A P£OVI t,,1,3 Na ?EED DATE:.. B.P.+__ ___..APPLICATION FOR BUILDING PERMIT ,,-.—_---.� -- FE / 4Y �. _ Date 3/g� , 20 /L/ NOT rY BUILDNI a (�' ('r�\ 1 RENT ,aT INSTRUCTIONS 76 1c�Q2 $ANI TO 4 RU FOB THE FOL@0A)k000B6KbTdM&ST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets p.f p&n 3�lte pll l l�`. Fee according to schedule. Ft,rPlot gtaf ah(5Q4 Union of lot and of buildings on premises,relationship to adjoining premises or public streets or areas andN r-v*FN,?INU 8, PL.UkIINNG 3. 1196TbA1WW covered by this a lication may not be commenced before issuance of Building Permit. 4 V4NWponC*987 16rfflh �i tion,the Building Inspector will issue a Building Permit to the applicant. Such a permit shall beFkeRt,(9;A*_ Wirfu#' sQAilable for inspection throughout the work. ALLeCIWf� $iCsll�ll9nh`bbc oiliged in whole or in part for any purpose what so ever until the Building Inspector issueKg &gNTqf0ecb0arQ9PESOFNL YOfiI,� l*ilfpj*-WMI"1 INS - �><dBif the work authorized has not commenced within 12 months after the date of r� issuahappotft06'0i CpTdQW v� 5§,months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize, in writing,the extension of the permit for an addition six months. Thereafter,a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York, and other applicable Laws, Ordinances or Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances,building code,housing code,and regulations,and to admit authorized inspectors on premises and in building for necessary inspections. (Signature of applicant or name,if a corporation) (Mailing address of applicant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder C/'u vJ Name of owner of premises (As on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer (Name and title of corporate officer) A,�+� O� occupA Builders License No. 1S UAl `��?� Plumbers License No. yy� v 1 1 Electricians License No. �/ J-36 /4 �' 111 1 `O U1 650- Other Trade's License No. NCj� 1. Location of land on which proposed work will be done: O� 7 or, of c. L� �.eel go �- House Number Street flainlet County Tax Map No. 1000 Section Block Lot Subdivision Ayn,c L—und.i'1Je Filed Map No. Lot 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy b. Intended use and occupancy 3. Nature of work(check which applicable): New Building Addition Alteration Repair Removal Demolition Other Work p (Description) . 4. Estimated Cost 1 �(�U , �� _ Fee c� . (To be paid on filing this application) 5. If dwelling, number of dwelling units Number of dwelling units on each floor If garage, number of cars 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of existing structures, if any: Front Rear Depth_ Height Number of Stories Dimensions of same structure with alterations or additions: Front Rear Depth Height Number of Stories 8. Dimensions of entire new construction: Front Rear Depth Height Number of Stories 9. Size of lot: Front Rear Depth 10. Date of Purchase Name of Former Owner 11. Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law, ordinance or regulation? YES NO 13. Will lot be re-graded? YES NO Will excess fill be removed from premises?YES NO �e 14.Names of Owner of premises Mailyn Address at Oride- L&I Phone No. 6.31 - (-/?7- �y88 Name of Architect Address Phone No Name of Contractor Address Phone No. 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO * IF YES, SOUTHOLD TOWN TRUSTEES & D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey, to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. 18. Are there any covenants and restrictions with respect to this property? * YES NO_� * IF YES, PROVIDE A COPY. STATE OF NEW YORK) SS: COUNTY OF ) c7 being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, CONNIE D. BUNCH Notary Public,State of New York (S)He is the ���j��i�cr C4-- No.01BU6185060 (Contractor,Agent, Corporate Officer,etc.) Ouaffied In Suffolk County Commission Expires April 14,20 of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be performed in the manner set forth in the application filed therewith. Jworn to before me thi day of 1 20 1 Notary Public Signature of plicant r �,\\Of SO(/r Town Hall Annex � Telephone(631)765-1802 � 54375 Main Road e�rr �.gg QQ P.O.Box 1179 c� rogenrichertftUtOVf l SOU[nOl� ny us SouthoK NY 11971-0959 ^Q�� I. BUa DING DEPARTMENT T{)WN flF SOLJTHOLD APPLICATION FOR ELECTRICAL INSPECTION ' REQUESTED BY: Date: 3 Company Name: T i Name: License No.: �01 A- 6 M E --- i' Address: /O = F3 Ya� Sv.i4 a (ems 7 1 y f 3 1_ Phone No.: _ ?3- JOBSITE INF=ORMATION (*Indicates required information) { *Name: *Address: i *Cross Street: *Phone No.: 3 l — 147?— 811-1 YY I Permit No.: j Tax-Map District: 1000 Section: Block: Lot: *BR/IIEFp DESCRIPTION OF ESCRIPTIONOF WORK(P'lea`s/e.Print/(Clearly) r�7� fry. (Please Circle All That Apply) *Is job ready for inspection: YES/ NO. Rough In Final *Do-you need a Temp Certificate: YES/ NO Temp Information(if needed) I *Service Size: 1 Phase 3Phase 100 150 200 300 350 400 Other ( . *New Service: Re-connect Underground Number of Meters Change of Service Overhead Additional Information: PAYMENT DUE WITH APPLICATION � E 824Request for Inspection Form k GENERAC® 14/17/2OkW WARDIAP SER JES Residential Standby Generators Air-Cooled Gas Engine son- INCLUDES: Standby Power Rating • True Power" Electrical Technology Models 006240-0; 006241-0, 006247-0 (Steel - Bisques - 14 kW 60Hz • Two Line LCD Multilingual Digital Models 006242-0, 006248-0 (Steel -Bisque, - 17 kW 60Hz Evolution" Controller (English/Spanish/ Models 006243-0, 006249-0 (Aluminum-Gray) - 17 kW 60Hz Ft'efch/P-drat geese) Models 006244-0, 006250-0 (Aluminum-Gray) -20 kW 60Hz • Two Transfer Switch Options Available: 100 Amp Pre-:Wired Switch or - 200 Amp Smart Switch. See Page 4 for Details. • Electronic-Governor • External Main Circuit Breaker, System Status & Maintenance Interval LED Indicators • Sound Attenuated Enclosure • Flexible Fuel Line Connector • Composite Mounting Pad -------- • Natural Gas or LP Gas Operation C&S LISTED • 5 Year Limited Warranty Note:CUL certification only applies to unbundled units and units packaged with pre-wired switches. • Capability to be installed within 18" of a building* Units packaged with the Smart Swttch:are UL certified.in the USA onry. *Only if located away from doors,windows and fresh air intakes,and unless otherwise directed by local codes. FEATURES O INNOVATIVE DESIGN 8 PROTOTYPE TESTING are key components O SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION. of GENERAC S success in "IMPROVING POWER-BY DESIGN:"-But it This state-of-the-art power maximizing regulation system is standard on doesn't stop there. Total commitment to component testing,reliability all Generac models. It provides optimized FAST RESPONSE to changing testing,environmental testing,destruction and life testing,plus testing load conditions and MAXIMUM MOTOR STARTING CAPABILITY by to applicable CSA,NEMA,EGSA,and other standards,allows you to electronically torque-matching the surge loads to the engine. Digital choose GENERAC POWER SYSTEMS with the confidence that these voltage regulation at±1%. systems will provide superior performance. O TRUE POWER" ELECTRICAL TECHNOLOGY: Superior harmonics O SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer and sine wave form produce less than 5% Total Harmonic Distortion for network provides parts and service know-how for the entire unit,from the utility quality power.This allows confident operation of sensitive electronic engine to the smallest electronic component, equipment and micro-chip based appliances, such as variabie speed HVAC - systems. O GENERAC TRANSFER SWITCHES. Long lite and reliability are O TEST CRITERIA: synonymous with GENERAC POWER SYSTEMS. One reason for this PROTOTYPE TESTED NEMA MG1-22 EVALUATION confidence is that the GENERAC product line includes its own transfer SYSTEM TORSIONAL TESTED MOTOR STARTING ABILITY systems and controls for total system compatibility. GENERAC® GENERAL 14/17/2OkW features and benefits Engine •Generac(OHVI)design Maximizes engine"breathing"for increased fuel efficiency. Plateau honed cylinder walls and plasma moly rings helps the engine run cooler,reducing oil consumption resulting in longer engine life. •"Spiny-lok"East iron pyl.inder walls Rigid construction and added durability provide long engine life: -Electronic ignition/spark advance These features combine to assure smooth,quick starting every time. -Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance,less maintenance and longer engine life. Now featuring,up to a 2 year/200 hour oil change interval. -Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil. -High temperature shutdown Prevents damage due to overheating. Generator •Revolving field Allows for a smaller,light weight unit that operates 25%more efficiently than a revolving armature generator. -Skewedsfafor PPci&dds a sr1rWth oufN waveformfWcompatiNfity with-electidnic equiprriel t: -Displaced phase excitation Maximizes motor starting capability. (Automatic voltage regulation Regulates the output voltage to±1%prevents damaging voltage spikes. -UL 2200 listed For your safety. Transfer Switch -Fully automatic Transfers your vital electrical loads to the energized source of power. -Pre-wired,color-coded conduits Ensures the easiest,trouble-free installation. (Pre-wired switches only) •DPM Technology Digital Power Management Technology allows for the smart control of two air conditioners without any additional (Smart Switch only) items. -Remote mounting Mounts near your existing distributionpanel for simple,low-cost Evolution'" Controls jAuto/MmUal/Off illuminated buttons Selects the operating mode and provides easy,at-a-glance status indication In any condition. •Sealed,raised buttons Smooth,weather-resistant user interface for programming and operations. -Utility voltage sensing Constantly monitors utility voltage,setpoints 60%dropout,80%pick-up,of standard voltage.. -Generator voltagesensing Constantly monitors generator voltage.I&ensure the cleanest:power del ivere6 tothehome, -Utility interrupt delay Prevents nuisance start-ups of the engine,adjustable 2-1500 seconds from the factory default se ting of 10 seconds by a qualified dealer. •Engine warm-up Ensures engine is ready to assume the load,setpoint approximately 5 seconds. -Engine cool-down Allows engine to cool prior to shutdown,setpoint approximately 1 minute. •RrQgra[nrrtableaeven:day.eXer�iser -ORerotes:engjpe to:preyept oil:seal:drying:and_danaage.betweep Rower:ogtages:byrunning the genarat4l for_12 minutes every week •Smart battery charger Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. •Main line circuit breaker Protects generator from overload. -Electronic governor Maintains constant 60 Hz frequency. Unit -Weather protective enclosure Ensures protection against mother nature and can withstand winds up to 150mph.Hinged key locking roof panel •for security. Lift-out front for easy access to all routine maintenance items.Electrostatically applied textured epoxy paint for added durability. •Enclosed critical grade muffler Quiet,critical grade muffler is mounted inside the unit to prevent injuries. •Small,compact,attractive Makes for an easy,eye appealing installation. -•SAE Sound attenuated enclosure ensures quiet operation, Installation System •1ft.(305mm)flexible fuel line connector -Composite mounting pad Easy installation. V E NERAL 14/17/2okW specifications Generator Model 006240-0,006241-0, 006242-0,006243-0,006246-0,006249-0 005244-0,006250-0 00644$0;(t6kiN) (tTkW) (20kW)- Rated Maximum Continuous Power Capacity(NG) 14,000 Watts* 16,000 Watts- 18,000 Watts' Rated Maximum Continuous Load Current—240 Volts(LP/NG) 58.3/58.3 70.8/66.6 83.3175 Main Line Circum Breaker 60 Amp 65 Amp 90 Am Number of Rotor Poles 2 2 2 PilW Factor 1.0 1A 1.0 Unit Weigh(PouridsAGios) 435/197.3471/213.6(Steel);437/198.2(Aluminum) 451/204.6 Sota»tou utf f: A:at•23-fL• ft—'Aft— eratoro eratin at•itontraktafad" 66 66 66- Engine Number of Cylinders 2 2 2 Cylinder Bloek Aluminum wtast-lronSleeve Ignition System Solid-state w/Magneto Solid-state w/Magneto Solid-state w/Magneto Compression Ratio 9.5:1 9.51 9.5:1 Oil Capacity Including Filter Approx.1.9 QtO.81. Approx 1.9 QtO.& Approx.1.9 Mt 1.81. Fuel Consumption Natural Gas W/hr(m3/hr) 1/2 Load 177(5.01) 193(5.47) 205(5.8) Full Load 279-(/.9) 312(8.83) 308(8.72) Liquid Propane tt3/hr(gal/hr)[Liters/hr] 112 Load 67.2(1.85)[6.99] 72.4(1.99)[7.53] 75.6(2.08)[7.87] Full Load 111.6 3.07 11.61 130 3.57 13.53 140 3.85 14.57 Controls Mode Buttons: Auto Automatic Start on UU14 failure.7 day exerciser. Off Stops unit.Plower is removed.'Control and chaW still operate. Engine Run Hours Indication Standard Utility Voltage L oss/Retum to Utility Adjustable from 140-171V/190-216V Run/Alarmftintenance Logs 50 Events Each Starter Lock-out $tarter cannot re-engage un111-5 sec.after engine has stopped: Charger Faull/Missing AC Warning Standard Automatic Voltage Regulation with Over and Under Voltage Protection Standard Safety Fused/Fuse Problem Protection Standard Overcrank/Overspeed(@ 72Hz)/RPM Sense Loss Shutdown Standard Internal F&KAncored Wiring Protection Standard Field Upgradable Firmware Standard "Sound levels are taken from the front of the generator.Sound levels taken from other sides of the generator may be higher depending on installation parameters.Rating definitions-Standby:Applicable for supplying emergency,power for the.duration.of the utility power outage. No overload capability is available.for this.rating. (All.ratings in accordance with BS5514,IS03046 and.DIN6271). 'Maximum wattage and current are subject to and limited by such factors as fuel Btu/megajoule content,ambient temperature,altitude,engine power and condition,etc. Maximum power decreases about 3.5 percent for each 1,000 feet(304.8 meters)above sea level;and also will decrease about 1 percent for each 6'C(10°F)above 16'C(60°F). GENER a cm 14/17/2okW switch options mie Pre-wired Features Model 006240-0(14 kW) 006242-0(17kW) available on 14&17kW models only • Electrically operated,mechanically-held contacts for fast,positive Current&W 100 100 connections. Utility Voltage Monitor FFuuo- • Rated for all classes of load, 100%equipment rated,both inductive and -Pick-up 80% 80% resistive. -Dropout 60% 60% 2 pole;250 VAC contactors. Exercise weekly for 12 minutes" Standard Standard • 30 millisecond transfer time. Total of Pre-wired Circuits 14 16 Dual coil design. No.15A 120V 4 5 No.20A 120V 6 5 • Main contacts are silver plated or silver alloy to resist welding and sticking. No.20A 240V 1 1 • NEMA 1 (indoor rated)enclosure is standard on the pre-wired switch. No.30A 240V - - No.40A 240V 1 1 • Pre-wired 30 foot(9.1 meter)whip to connect to the provided 5 foot pre- No.50A 240V - 1 wired whip and external connection box. r Pre-=wired 2 foot(0-61 meter)whip,,color coded to connect into the existing electrical panel. 'Function of Evolution Controller Dimensions Mechanical Dimensions Height Width Amps H1 H2�WIW�2Depth 100 23.5 in 26.4 in 8.3 in 12.6 in 6.3 Fit H7 597mm 671.7mm 211mm 320.7mm 159.6mm Wire Ranges Ams I Conductor Lu Neutral Lug Ground Lug 100 210-#14 2/0 �,- wz- Smart Switch Features Model 006241-0(14kW)MO6243-0(17kW)/006244-0(200) • Includes Digital Power Management Technology standard(DPM): • Intelligently manages two air conditioner loads with no additional Current Rating(Amps) 200 hardware. Utility Voltage Monitor(Fixed)' • Up to four more large(120/240VAC)loads can be managed when "Pick-up 80% used in conjunction with Power Management Modules(PMM"). -Dropout 60% • Electrically operated,mechanically-held contacts for fast, clean Exercise weekly for 12 minutes* Standard connections. Enclosure Type NEMA/UL 311 • Rated for all classes of load, 100%equipment rated,both inductive and resistive. Wj Range 250MCM-#6 • 2 pole,250 VAC contactors. 'Function of Evolution Controller • Service equipment rated,dual coil design. • Rated for both aluminum and copper conductors. • NEMA/UL 3R aluminum outdoor enclosure. Main contacts are silver plated or silver alloy to resist welding and sticking. `"Note:PMM starter kit is required prior to using the modules. Dimensions 200 Amps 1201240,1e Open Transition Service Rated Height Width Deplf♦ H1 H2 W1 W2 Inches 27.24 30.0 11.4 13.5 1 7.09 mm 692.0 762.4 289.0 343.0 1 180.0 BENE-RACO _ 14/17/2okW available accessories 005819-0 26R Wet Cell Battery Every standby generator requires a battery to start, the system.Generac offers the recommended 26R wet cell battery for use with all air-coded standby pt -oduct ff the temperature regularly falls below 32-F(0-C),inst `all a cold weather kit to maintain tial batter 006212-D Cold Weather Kit � � Y ( ) optimal Y and oil temperatures. Kit consists of a battery warmer, and oil filter heater with buil[-in thermostats. Auxiliary Transfer Switch Contact The auxiliary transfer switch contact kit allows the transfL'r switch to lock out a single large electrical load 00562t=D. Kit you may not need.Not compatible with 50 am switches. Y Y p p pre-wired The fascia base wrap snaps together around the bottom of t,'he new air cooled generators.This offers 005839-0-Bisque Fascia Base Wrap Kit* a sleeki ganteured apigearanee as well as offering protection from rodents and insects b coverin the 005666-0-Gra Y (-Standard on-2 __ — -.._... .. .- -y-- -...9_ - lifting holes located in the base. 005703-0-BisqueIf the generator enclosure is scratched or damaged,it is important to touch-up the paint to protect from 005704-0-Gray Paint Kit* Uwe corrosion.The paint kit includes the necessary paint to pri.ipedy maintain or touch-up a generator enclosure. 006484-0-14 Er 17kW Generac's scheduled maintenance kits provide all the hardware nese.ssary to perform complete refine 006485-0-20kW Scheduled Maintenance Kit maintenance on a Generac automatic standby generator. 005928-0 Wireless Remote Completely wireless and battery powered,Generads wireless remote n tonitor provides you with instant status information without ever leaving the house.Not compatible with C.orePower or EcoGen systems. Remotely control-generator functions with the advanced model's LCD dist)1ay.In addition to remote 005951-0 Advanced Wireless Remote testing of the generator,set the excercise cycle and maintenance interval re minders.Not compatible with CorePower or EcoGen systems. The PMM Starter Kit consists of a 24VAGi fief installed transformer that eneljles tie use of the 24VAG 006199-0 PMM Starter Kit Power Management Modules(PMMs)and one PIvIM.The standard controNer(n vithout starter kit)can control two HVAC loads with no additional hardware.Not compatible with pre-%/!red switches. Power Management Module(50 Power Management Modules are used in conjunction with the Smart Switch to irdcrease its power 006t860. Amps) management.capabriities:ItgivestheSmartSwitch•additional-powermanagememtftbtiftynotfound in. any other transfer switch.Not compatible with pre-wired switches.Note:PMM Stai,ter Kit required. Generac's Mobile Link device allows you to check the status of your generator from anywhere that you 006463-0 t- I Mobile Link."Device have access to an Internet connection from a PG or with any smart device.You wig even be notified when a change in the generator's status occurs via e-mail or text message. *Note:Bisque kits are used in conjunction with steel enclosures.Gray kits are used in conjunction with aluminum enclosures. dimensions mrnm�rrrrrw.rri�rrrr�m.rmrrr�rr.rrr - m Dimensions sho m are aWcDd rate.CotW yorr Generac dealer for certified drawings.DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES. 637.6 nun [25.1 in.] 1218 mm _ [47.9 in.] 731.9 mm -[28.8 in.] L _ 642 mm [25.3 in.] 762 mm[3.0 in.]J 1226 mm PEA GRAVEL [48.3 in.] --- MINIMUM LEFT SIDE VIEW FRONT VIEW GENE RAC® Generac Power Systems,Inc. - S45 VV29290 HWY.59, Waukesha,WI 53189 - generac.com ©2013 Generac PowerSystems,Inc. AN rights reserved. AN specifications are subject to change.Without notice. Bulletin 0197990SBYT-Printed In USA,0529/13 - I Town Hall Annex Telephone(631)765-1802 i> 54375 Main Road N '� ow(63 )76 -995 ro ersichert nohod .nVms R.O.Box 1179 Southold,NY 11971-0959 I' i- BUI DING DEPARTMENT TOWN,OFSOUTHOLD APPLICATION FOR ELECTRICAL INSPECTION REQUESTED BY: Date: - Company Narrle- `JInOr i'OW�/'- e� r� c ( � frrcc r� T..•c i- Name: AJI CJX6 t s License No.:No.: 1101 ,E-3 Address: 10g Fry SU,`kt- Phone No.: 631 - 3 ?S_z Y a,,1- I JOBSITE INFORMATION (*Indicates required information) I *Name: t��`�x�! Nv -*gess: i *Cross Street: -- 1 Phone No.: ( 3 t - 4??- --- Permit No.: i Tax-Map District:: 1000 secti-o.m Block: -Lot: 3 *BRIEF DESCRIPTION OF WORK(Please Print Clearly) / k-07 (Please Circle All That Apply) Is job ready for inspection: YES! NO. Rough In Sinai *Do.you need a Temp Certificate: YES/ NO 7'ernp-Information(If needed)- 'Service Size: 1 Phase 3Phase 100 150 200 300 350 . 400 Other i *New Service: Re-connect Underground Number of Meters Change of Service Overhead Additional Information: PAYMENT DUE WITH APPLICATION I i 82-Request for Inspection Form j