Loading...
HomeMy WebLinkAbout38766-Z Town of Southold Annex 5/9/2014 1,_����' -=i P.O. Box 1179 54375 Main Road +�, j4,1 Southold, New York 11971 CERTIFICATE OF OCCUPANCY No: 36901 Date: 5/8/2014 THIS CERTIFIES that the building ELECTRICAL Location of Property: 10095 Route 25, Mattituck, SCTM#: 473889 Sec/Block/Lot: 142.-1-26 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this officed dated 4/4/2014 pursuant to which Building Permit No. 38766 dated 4/4/2014 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: electric for exit and emergency fixtures and hood system for a restaurant. (CJ's American Grill) The certificate is issued to Mattituck Plaza LLC (OWNER) of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 38766 11, 5/7/14 PLUMBERS CERTIFICATION DATED ORM E 4101 Au ho e. Si_ ature ,iilliflON TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE '$.�,� y i SOUTHOLD, NY 1 ;4` f BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 38766 Date: 4/4/2014 Permission is hereby granted to: Mattituck Plaza LLC PO BOX 77 Mattituck, NY 11952 To: Commercial Electrical At premises located at: 10095 Route 25, Mattituck SCTM # 473889 Sec/Block/Lot# 142.-1-26 Pursuant to application dated 4/4/2014 and approved by the Building Inspector. To expire on 10/4/2015. Fees: ELECTRIC $120.00 Total: $120.00 III Building Inspector ,�,,, ice. le NI%IpF SO(/r�,ol Town Hall Annex ��� : Telephone(631)765-1802 54375 Main Road i lig illi % Fax(631)765-9502 P.O. Box 1179 : v' � i . roger.richert(a�town.southold.ny,us Southold,NY 11971-0959 %�` 4:::1 COUNTY, 8.' BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION Issued To: Mattituck Plaza--CJ,s American Grill Address: 10095 Main Rd--Unit-8 City: Mattituck St: NY Zip: 11952 Building Permit#: 38766 Section: 142 Block: 1 Lot: 26 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: JJW Electric Inc License No: 4664-me SITE DETAILS Office Use Only Residential Indoor X Basement Service Only Commerical X Outdoor 1st Floor X Pool New Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures HID Fixtures Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel NC Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel NC Blower Range Recpt Fluorescent Fixture Pumps Transformer Appliances Dryer Recpt Emergency Fixtures Time Clocks Disconnect Switches Twist Lock Exit Fixtures TVSS Other Equipment: 1-combination exit/emergency fixture, 1-exit fixture, 1-emergency fixture Notes: Inspector Signature: Date: May 7 2014 81-Cert Electrical Compliance Form.xls ,11�,�o��OF o�`` VtcP =tea / �y�DUNT'1,��,•�� TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLUMBING [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING / STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] CAULKING REMARKS: DAT E 0/(47 INSPECTOR Z Town Hall Annex * *; Telephone(631)765-1802 54375 Main Road ` a Q � roaer.richertd n a a nv.us P.O.Box 1179 Southold,NY 11971-0959 `3 AO D ��� . BUILDING DEPARTMENT TOWN OF SOUTHOLD APPLICATION FOR ELECTRICAL INSPECTION REQUESTED BY: Date: 3/30/(." Company Name: 7`'„ 74) EZ /<, • Name: o�.� License No.: 5 G '-f6.6e1 Address: iFePcc 3d , e_cj,�� , 9 3/ • Phone No.: 13-66. JOBSITE INFORMATION: (*Indicates required information) *Name: ( I Its 47,0cric, c6r' 11 tl-C_ *Address: 16O95-- Gin/ TYI a i/1 Poo o Meti-ti lc i1J 1/�c)- *Cross Street: �J *Phone No.: G 5i — 3/ 5 5`3 t Permit No.: 3k7(9e19 Tax•Map District: 1000 Section: jq-.. . Block: I Lot: J.4' *BRIEF DESCRIPTION OF WORK(Please Print Clearly) • s714-1leo 0 L''>4'Z—G/�,�7''' o lye"( N&wk. =.Asr,4ctj /rre,tv ere,. 471. —eit - '• P 17c>/t -� �xj.�f yr s { (Please Circle All That Apply) *Is job ready for inspection: ES/ O Rough In Final *Do you need a Temp Certificate: Y p YE / N Temp information(If needed) l *Service Size: 1 Phase 3Phase 100 150 200 300 350 400 Other *New Service: Re-connect Underground Number of Meters Change of Service Overhead Additional Information: PAYMENT DUE WITH APPLICATION 82-Request for Inspection Form o 1 AES MANUFACTURER: SEAL TIGHTS (TYP.) RANGE GUARD: _RG 1.25 GAL. RG 2.5 GAL. RG 4 GAL. X RG 6 GAL. � — __ 1�_ Piping Material BLACK SCH 40 Max. Rise 12' :" :: 14"x14" DUCT 14"x14" DUCT Supply Pipe Size 3/4" Branch Pipe Size 1/2" DROPS 3/8" Gas Valve Type: MECH Size 2" Manufacturer ASCO ADP ADP 14' HOOD ADP ADP Detector Temperature Rating: 360', 450' & 500' 1 Hood Size: 14' Duct Size: (2) 14"X14" r - - - - - - - L� —ICI- - - - - - - -®- -Ie4� - - -® CONTROL 360' 360' 360' 500' 450' 450' o EQUIPMENT SURFACE NOZZLE HEAD -~ ADP 1 I_ADP J I TYPE QTY. AREA TIP#/QTY' HEIGHTS LOCATIONS J ► N �— — T T T T T DUCT 2 14"X14" ADP 4 0"-6" 0"-6" IN OPENING I I I I PLENUM 1 14 FT. ADP 2 0"-6" FROM END OF PLENUM RC I I I I I I I 6 BURNER RANGE 2 36"x27" R 4 20"-42" CENTER 6.0 ♦ ♦ ♦ ♦ I ♦ ♦ UPRIGHT BROILER 1 32"x20" ADP 1 - TOP 4" OF COMP. t f< GAL. R R R R F F FRYER 2 14"x23.5" F 2 27.5"-45" 45' TO 90' • L ADP 6„ _ . i Lo PULL I MIN. TO EDGE STATION 32"x20" a` ce OF HOOD ON c° — — D X UPRIGHT >- o r o BOTH SIDES 1 Q I 2" GAS 36"x27" 36"x27" BROILER u m m RANGE GUARD - RG 6.0 GALLON - MAX. FLOW POINTS = 18 VALVE 6 BURNER 6 BURNER ;1- , E E2 POINTS USED = 15 RANGE RANGE KS ° M ° L — X x TOTAL PIPE VOLUME NOT TO EXCEED 400 CUBIC INCHES — . 3 3 MAX. PIPE LENGHT 75 FT. ' RG-6.0 GAL. CYLINDER #60-20005-001 LINK HOUSING #804548 DISCHARGE ADPT. KIT #83-844908-000 MANUAL RELEASE #B100030 VENT PLUG #9196984 360' LINK #WK-282664-000 A FIRE EXTINGUISHER SHELF BRACKET #100013 450' LINK #WK-282663-000 WITH A MINIMUM RATING UCH #B120099 500' LINK #WK-282666-000 FRONT VIEW OF CLASS K MUST BE DUAL SPDT #9197228 2" GAS VALVE #B120075 3/8"=I-0" INSTALLED WITHIN THE ADP NOZZLE #87-120011-001 SCALE: VICINITY OF THE F NOZZLE #87-120012-001 COOKING AREA. R NOZZLE #87-120014-001 SCFM STAMP NOTES: Anderson Fire x Fryers to have High Limit Control to shut off fuel at 425'. 9 O'Neil Ave., Bay Shore, N.Y. 11706 x Detectors shall be located over every piece of equipment. x The System installed as per manufacturers specs and the AHJ. Tel: 631-435-1002 x The System has been installed as per UL300. x The following functions to operate upon system discharge: Contact: Patrick Turro * Supply air damper closes * Gas fuel shuts off in kitchen * Exhaust fan remains on * Electric fuel shut off under hood �P,.S E"a'^EyFq'i * All systems to activate simultaneously in same hazard area. :1 wi ' T . PEGASUS ENGINEERING * Fire Alarm sholl activate if one is installed in building. x Manual Pull is located a maximum 20 ft. from hood and 4 ft. 6 Nodworny Lone, Stony Brook, N.Y. 11790-2100 from floor. PLANNING A BETTER WORLD x All fuel sources are GAS unless otherwise noted. • C* 631-751-6600 ___ _- ZSOP"di WWW.PEGASUS.ENG.PRO UNAUTHORIZED ALTERATION OF, OR THE ADDITION SEAL TO PLANS OR DOCUMENTS BEARING THE SEAL JOB SITE: OF A LICENSED PROFESSIONAL ENGINEER IS A VIOLATION OF SECTION 7209, SUBDIVISION 2 OF CJ's American Grill THE HE NEW NEW YORK STATE EDUCATION LAW. - ANY ALTERATION TO THIS DOCUMENT MUST BE DONE BY A PERSON ACTING UNDER THE DIRECT ` i p L 10095 Unit 8, Main Rd., Mattituck, N.Y. 11952 SUPERVISION OF A LICENSED PROFESSIONAL IN ACCORDANCE WITH THE STATE EDUCATION LAW. COPIES OF THIS DOCUMENT NOT MARKED WITH AN ORIGINAL OF THE PROFESSIONAL ENGINEERS DATE: SCALE: DWG BY: DWG N0 INKED OR EMBOSSED SEAL SHALL NOT BE 04/1 7/1 4 AS SHOWN A.X.C. 1 CONSIDERED TO BE VALID TRUE COPIES. - System Design 3-6.1.1.2 Ducts 50 to 100 inches in Perimeter Two ADP nozzles, P/N 87-120011-001, pointing in the same direction are required for protection of ducts with perimeters greater than 50 inches and less than or equal to 100 inches. Ducts can be of unlimited length(refer to Figure 3-30). For other option of ducts up to 75 perimeter inches (See Figure 3-32). Note: All Range Guard systems are listed by UL and ULC for use with the exhaust fan either on or off when the system is discharged. DUCT t==== HOOD X 4/x+/ + +X +/.d +/d MAX.DIAMETER 31.83 In.(809 mm) /<x /x NOZZLES TO BE ALONG ONE 25 in.(635 mm) CENTERLINE AT THE 1/4 POINTS. MAX.SIDE 1 Fp� • NOZZLES TO BE 0-6 In.(0-152 mm) UP FROM ENTRANCE OF VERTICAL DUCT MAX.DIAGONAL 11.78 in.(300 mm) MAX.DIAGONAL TYP.(2)ADP NOZZLES 11.78 in.(300 mm) SQUARE RECTANGULAR ROUND C. r-- ADP NOZZLE 0 to 6 In. rOito 152 mm) DUCT ENTRANCE C OF VERTICAL DUCT 14/1 C I , � OF HORIZONTAL DUCT 2-4 in.(51 mm-102 mm) / ADP NOZZLE � AIM POINT NOZZLE TIP TO DUCT HIP VERTICAUHORIZONTAL DUCT Figure 3-30. Duct Protection Using Two ADP Nozzles, P/N 87-120011-001 April 2009 3-36 P/N 60-9127100-000 System Design 4 ft. NOZZLE (1.2 m) DUCT ,/ 4 ft. DUCT 0,0e :,...... 4 ft. (1.2 m) (1.2 m)"." to ;.*.°' / NOZZLE ®��� 10 ft. k41 (6 20 ft. (3 m) AC ft m) NOZZLE (1.2 m))/ "V" FILTER BANK COVERAGE "V" FILTER BANK COVERAGE 10 ft.(3 m) PLENUM 20 ft.(6 m)PLENUM <>1.evi.2. - NOZZLE 3/4H H f "V" FILTER BANK COVERAGE(END VIEW) `-"" , At, 4 ft. NOZZLE piiii:'2 ni)f w f DUCT � „ �" 4 ft. DUCT -5.--,,p, : (1.2m) / ®�' (12m) Jr �i re)41 ✓ N OZZLE 01 .. 10 ft , `` 77- (3 m) /� . (6 m)ta,�\ 4 ft.`• (1.2 m))". NOZZLE \, SINGLE FILTER BANK COVERAGE N. SINGLE FILTER BANK COVERAGE 10 ft.(3 m) PLENUM 20 ft.(6 m) PLENUM -1+113 Wk- I 3/4 H1. ; T -- ------- / 1 IA- w -*I SINGLE BANK FILTER COVERAGE(END VIEW) Figure 3-28. ADP Protection Nozzle, P/N B120011 Apr-112009 3-34 P/N 60-9127100-000 System Design 3-4.2 18-1/2 in. x 24-1/2 in. Deep Fat Fryer With Drip Board Table 3-3. F Nozzle Coverage Area Items Parameters Maximum Hazard Area 18-1/2 in.x 18 in. (470 mm x 457 mm) Maximum Appliance Area(with drip board) 18-1/2 in.x 24-1/2 in. (470 mm x 622 mm) Nozzle Aim Midpoint of module area per nozzle Nozzle Location(at an angle of 45°or more from the horizontal 27-1/2 in.(699 mm)Min. above each module) 45 in. (1143 mm)Max. Module Area(half of hazard area) 18-1/2 in.x 9 in. (470 mm x 229 mm) AN F NOZZLE MAY BE LOCATED M AN F NOZZLE MAY BE LOCATED In. 45 ANYWHERE WITHIN THE GRID -\ ANYWHERE WITHIN THE GRID (1143 mm) (1143 mm) ' _ MAX. DIAGONAL FROM 45M. I• •,` •�I�•;•►,~ AIM POINT (1143 mm) ' •■• „ ••• �` 45 In. ♦�-��•�,I•.� 50 (1143 mm) MAX. \ivrt\Ivrt/ ■■■ MAX. 27.1/2 In. ♦r'."::i• Pa.;:i'. IMAGINARY LINE (899 mm) DIVIDING MODULES MIN. MIDPOINT OF MODULE AREA FRONT OF 19-1Q In. APPLIANCE (470 mm) MAX. 9In. 1— 9In. (229 mm) (229 mm) -Poi • 2412 In. (622 mm) MAX. SIDE VIEW 2 F NOZZLES ARE REQUIRED FOR THIS APPLIANCE AN F NOZZLE MAY AN F NOZZLE MAY BE LOCATED ANYWHERE i LOCATED ANYWHERE WITHIN THE GRID WITHIN THE GRID VIA P:111P / NOZZLE LOCATION i , �F� 45 OR MORE FROM ♦♦ ♦♦ i i/ `4°j -. HORIZONTAL(TYP) ♦ ♦/ ww ♦ A /�C ♦ i ♦ i w ♦i ♦//As AIM POINT: MIDPOINT OF HAZARD AREA HAZARD AREA DRIP BOARD 16.12 In.(4T0 mm)MAX. 24-112 In.(622 mm)MAX. APPLIANCE AREA SIDE VIEW Figure 3-3. 18-1/2 in.x 24-1/2 in. (470 mm x 622 mm) Deep Fat Fryer P/N 60-9127100-000 3-7 April 2009 System Design 3-4.10 Two Burner Ranges Table 3-14. R Nozzle Coverage Area—Two Burner Range Items Parameters Maximum Hazard Length 28 in.(711 mm) Nozzle Aim Midpoint of hazard area Nozzle Location-Anywhere within the area of a circle 20 in. (508 mm)Min. generated by a 9 in. (229 mm)radius about the midpoint 42 in. (1067 mm)Max. Note:Shape of burner not important. + �18in.(457mm)DIA. # — 42 In.(1067 mm)MAX. (FROM TOP OF RANGE) 1 A A'R'NOZZLE MAY BE ! LOCATED ANYWHERE WITHIN THE SHADED AREA 20 In.(508 mm)MIN. # AIM POINT:MIDPOINT OF (FROM TOP i HAZARD AREA OF RANGE) WSW / 28 in.(711 mm)MAX. Irfr 14 In.(356 mm)MAX.BURNER HAZARD AREA CENTERLINE TO CENTERLINE LENGTH Mgr Figure 3-11. R Nozzle Coverage for a 2-Burner Range April 2009 3-16 P/N 60-9127100-000 System Design 3-4.9 Four Burner Ranges Table 3-13. R Nozzle Coverage Area—Four Burner Range Items Parameters Maximum Hazard Area 28 in.x 28 in. (711 mm x 711 mm) Nozzle Aim Midpoint of Hazard Area Nozzle Location—Anywhere within the area of a circle 20 in. (508 mm)Min. generated by a 9 in.(229 mm)radius about the midpoint 42 in. (1067 mm)Max. Note: Shape of burner not important. 18 in.(457 mm)DIA. 1 _ 42 in.(1067 mm)MAX. ' (FROM TOP OF RANGE) I • I A'R'NOZZLE MAYBE i LOCATED ANYWHERE WITHIN THE SHADED AREA • �+ i 20 In (508 mm)MIN. _ / j... AIM POINT:MIDPOINT OF (FROM TOP OF HAZARD AREA RANGE) • 4011 r �� inow 28 In.(711 mm) 14 In.(356 mm)MAX MAX.HAZARD BURNER CENTERUNE AREA LENGTH i TO CENTERLINE nil. i ii 461.1117 nor i 14 in.(356 mm)MAX. BURNER CENTERLINE TO CENTERLINE /-- 28 In.(711 mm)MAX. -P• HAZARD AREA WIDTH Figure 3-10. R Nozzle Coverage for a 4-Burner Range P/N 60-9127100-000 3-15 April 2009 System Design 3-4.13 Upright Broilers Table 3-19.ADP Nozzle Coverage Area Items Parameters Broiler Compartment With Maximum Internal Horizontal 30-1/4 in.x 34 in. (768 mm x 864 mm) Dimensions Nozzle Aim Through grill toward the center of the grease drain-off opening Nozzle Location Within the top 4 in. (102 mm)of space in the broiler compartment. Commonly mounted near the front opening and directed inside the broiler BROILER _ EXHAUST COMPARTMENT RM I G ; DUCT *VE■ GRILL 4 in. (102 mm) ; > MAX. ;4 1 4 n. 4..._ 34 In.(864 mm) (768 mm)MAX. ' y MAX. GREASE • a �--14GREASE DRAIN PANJ DRAIN-OFF J FRONT J U (BROILER DOOR REMOVED) RIGHT SIDE NOTE: DIMENSIONS SHOWN ARE INSIDE BROILER COMPARTMENT ADP NOZZLES SHOULD BE MOUNTED ON THE PERIMETER OF THE BROILER TOP(SHADED AREA). IT SHOULD BE DIRECTED THROUGH THE GRILL TOWARD THE CENTER OF THE GREASE DRAIN-OFF OPENING. NOZZLE DISCHARGE SHALL NOT BE OBSTRUCTED BY ANY STRUCTURAL PART OF THE BROILER. Figure 3-15. ADP Nozzle Placement for Upright Broilers April 2009 3-20 P/N 60-9127100-000