HomeMy WebLinkAbout38636-Z Town of Southold Annex 5/8/2014
P.O.Box 1179
54375 Main Road
Southold,New York 11971
CERTIFICATE OF OCCUPANCY
No: 36903 Date: 5/8/2014
THIS CERTIFIES that the building GENERATOR
Location of Property: 115 Chardonnay Dr, Southold,
SCTM#: 473889 Sec/Block/Lot: 51.-3-3.5
Subdivision: Filed Map No. Lot No.
conforms substantially to the Application for Building Permit heretofore filed in this officed dated
12/31/2013 pursuant to which Building Permit No. 38636 dated 1/23/2014
was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for
which this certificate is issued is:
ACCESSORY GENERATOR AS APPLIED FOR
The certificate is issued to Konstantaras,Katy
(OWNER)
of the aforesaid building.
SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL
ELECTRICAL CERTIFICATE NO. 38636 05-07-2014
PLUMBERS CERTIFICATION DATED
Authorized Signature
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
TOWN CLERK'S OFFICE
� �' SOUTHOLD, NY
BUILDING PERMIT
(THIS PERMIT MUST BE KEPT ON THE PREMISES
WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS
UNTIL FULL COMPLETION OF THE WORK AUTHORIZED)
Permit#: 38636 Date: 1/23/2014
Permission is hereby granted to:
Konstantaras, Katy
835 Chablis Path
Southold, NY 11971
To: install an Accessory Generator as applied for
At premises located at:
115 Chardonnay Dr, Southold
SCTM #473889
Sec/Block/Lot# 51.-3-3.5
Pursuant to application dated 12/31/2013 and approved by the Building Inspector.
To expire on 7/25/2015.
Fees:
ACCESSORY $100.00
ELECTRIC $85.00
CO -ALTERATION TO DWELLING $50.00
Total: $235.00
Building Inspector
Form No.6
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
TOWN HALL
765-1802
APPLICATION FOR CERTIFICATE OF OCCUPANCY
This application must be filled in by typewriter or ink and submitted to the Building Department with the following:
A. For new building or new use:
1. Final survey of property with accurate location of all buildings,property lines, streets,and unusual natural or
topographic features.
2. Final Approval from Health Dept. of water supply and sewerage-disposal(S-9 form).
3. Approval of electrical installation from Board of Fire Underwriters.
4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1%lead.
5. Commercial building,industrial building,multiple residences and similar buildings and installations,a certificate
of Code Compliance from architect or engineer responsible for the building.
6. Submit Planning Board Approval of completed site plan requirements.
B. For existing buildings(prior to April 9,1957)non-conforming uses,or buildings and"pre-existing"land uses:
1. Accurate survey of property showing all property lines,streets,building and unusual natural or topographic
features.
2. A properly completed application and consent to inspect signed by the applicant.If a Certificate of Occupancy is
denied,the Building Inspector shall state the reasons therefor in writing to the applicant.
C. Fees
1. Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00,Alterations to dwelling$50.00,
Swimming pool$50.00,Accessory building$50.00,Additions to accessory building$50.00,Businesses$50.00.
2. Certificate of Occupancy on Pre-existing Building- $100.00
3. Copy of Certificate of Occupancy-$.25
4. Updated Certificate of Occupancy- $50.00
5. Temporary Certificate of Occupancy-Residential$15.00,Commercial$15.00
Date.
New Construction: Old or Pre-existing Building: i/ (check one)
Location of Property: $vZ,:� C RA61 IS- Ph+1k &-Z46"�Ajj 1
House No. Street Hamlet
Owner or Owners of Property: '1 y �ONS�A N`�792FcS
Suffolk County Tax Map No 1000, Section Block Lot S--
Subdivision Filed Map. Lot:
Permit No. Date of Permit. Applicant:
Health Dept.Approval: Underwriters Approval:
Planning Board Approval:
Request for: Temporary Certificate Final Certificate: (check one)
Fee Submitted: $
Applic a
pF SO(/l,�ol
Town Hall Annex Telephone(631)765-1802
54375 Main Road Fax(631)765-9502
P.O.Box 1179 rog er.riche rt(a-town.Southold.ny.us
Southold,NY 11971-0959
c4UNT1,�
BUILDING DEPARTMENT
TOWN OF SOUTHOLD
CERTIFICATE OF ELECTRICIAL COMPLIANCE
SITE LOCATION
Issued To: Katy Konstantaras
Address: 115 Chardonnay Dr (835 Chablis Path) City: Southold St: NY Zip: 11971
Building Permit#: 38636 Section: 51 Block: 3 Lot: 3.5
WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE
Contractor: DBA: Roof Diagnostics License No: 34280-me
SITE DETAILS
Office Use Only
Residential X Indoor X Basement X Service Only
Commerical Outdoor X 1st Floor Pool
New Renovation 2nd Floor Hot Tub
Addition Survey Attic Garage
INVENTORY
Service 1 ph Heat Duplec Recpt Ceiling Fixtures HID Fixtures
Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors
Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors
Sub Panel A/C Blower Range Recpt Fluorescent Fixture Pumps
Transformer Appliances Dryer Recpt Emergency Fixture Time Clocks
Disconnect Switches Twist Lock Exit Fixtures TVSS
Other Equipment: installation of 10KW standby generator with 100a transfer switch
Notes:
Inspector Signature: Date: May 7 2014
81-Cert Electrical Compliance Form.xls
Of SObly��
� 'IF
C
'b
TOWN OF SOUTHOLD BUILDING DEPT.
765-1802
INSPECTION
[ } FOUNDATION 1ST [ } ROUGH PLUMBING
[ J FOUNDATION 2ND [ ] INSULATION
[ J FRAMING / STRAPPING [ ] FINAL
[ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION
[ ] FIRE RESISTANT CONSTRUCTION ] FIRE RESISTANT PENETRATION
[ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL)
[ ] CODE VIOLATION [ ] CAULKING
REMARKS:
DATE 1 INSPECTOR t
FIELD Ilv3PE N 18ORT DATE COMMENTS
b
FOUNDATION(1ST) V.1
FOUNDATION(ZND)
ROUGH FRAMINQ&
PLUMBING
d
S
INSULATION PER N.Y.
H
STATE ENERGY CODE
FINAL
ADDITIONAL COMMENTS
,460-
U
�rn
TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST
BUILDING DEPARTMENT Do you have or need the following,before applying?
TOWN HALL Board of Health
SOUTHOLD,NY 11971 4 sets of Building Plans
TEL:(631)765-1802 Planning Board approval
FAX:(631)765-9502 3 Survey
SoutholdTown.NorthFork.net PERMIT NO. V k
R tic Form
S.D.E.C.
tees
1 d Permit
Examined 1- 20 DEC 31 2013 co -Water Assessment Form
Approved / L 20 Ma 1 to:
Disapproved a/c R',.!)�
TO"' U= rOLD Ph e:
Expiration ) 20 2�
Building Inspector
APPLICATION FOR BUILDING PERMIT
Date ,20
INSTRUCTIONS
a.This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4
sets of plans,accurate plot plan to scale.Fee according to schedule.
b.Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or
areas,and waterways.
c.The work covered by this application may not be commenced before issuance of Building Permit.
d.Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant.Such a permit
shall be kept on the premises available for inspection throughout the work.
e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector
issues a Certificate of Occupancy.
f.Every building permit shall expire if the work authorized has not commenced within 12 months after the date of
issuance or has not been completed within 18 months from such date.If no zoning amendments or other regulations affecting the
property have been enacted in the interim,the Building Inspector may authorize,in writing,the extension of the permit for an
addition six months.Thereafter,a new pemtit shall be required.
APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the
Building Zone Ordinance of the Town of Southold,Suffolk County,New York,and other applicable Laws,Ordinances or
Regulations,for the construction of buildings,additions,or alterations or for removal or demolition as herein described.The
applicant agrees to comply with all applicable laws,ordinances,building code,housing code,and regulations,and to admit
authorized inspectors on premises and in building for necessary inspections.
(Signature o p t or name,if a corporation)
7,9 &, /,6v2 0/ .-5y Ae&P Offtdai�
(Mailing address of applicant)
c�iid'thi,�l1�)Sei� NQ-1 L L
State whether applicant is owner,lessee;agent,architect,engineer,general contractor,el r
CQru$2wr�'rca2 DATE. B.P. # Z
Name of owner of premises KP%T O +pt W et R ES FEE: l cq BY
(As on the tax roll or latest deldOTIFY BUILDING DEPARTNIE-�J1
If appli�ar�oration,sig0`a of duly authorized officer 765-1802 8 AM TO 4 PM FOR 1 f?,
� FOLLOWING INSPECTIONS:
ame and fftlWciorporate officer) 1. FOUNDATION TWO REQUIRED
Builders License No. FOR POURED CONCRETE
Plumbers License No. � gj'yS — M P 2. ROUGH-FRAMING,PLUMBING,
Electricians License No.3YL$O _ A./� STRAPPING, ELECTRICAL&CAULKI^,I
Other Trade's License No. 3. I� �10
h f-J-4'`'FINAL`IONSTRUCTION &ELECTRICA;
1. Lo tion of land on w 'ch proposed work will be done: 5 MUST BE COMPLETE FOR C.O.
ON TION SHALL MEET THE
House Number Street Hamlet r I D F N F�`,.
\,'-,riK SATE. NOT RESPONSIBLE FOR
County Tax Map No. 1000 Se n . Block 3 DES � pjt;;ONSTRUCTION ERRORS
- .
Subdivision In .
> Filed Mai No. Lot
2. State existing use and occupancy of premises and intended use and occupancy of proposed construction:
a. Existing use and occupancy r✓//�►
b. Intended use and occupan cy
3. Nature of work(check which applicable):New Building Addition Alteration
Repair Removal Demolition Other Work��c xQ_
(Description)
4. Estimated Cost IT;Doo Fee
(To be paid on filing this application)
5. If dwelling,number of dwelling units Number of dwelling units on each floor
If garage, number of cars 2L
6. If business,commercial or mixed occupancy,specify nature and extent of each type of use.
7. Dimensions of existing structures,if any:Front Rear Depth
Height Number of Stories
Dimensions of same structure with alterations or additions: Front Rear
Depth Height Number of Stories
8. Dimensions of entire new construction:Front Rear Depth
Height Number of Stories
9. Size of lot:Front Rear Depth
10.Date of Purchase Name of Former Owner
11.Zone or use district in which premises are situated
12.Does proposed construction violate any zoning law,ordinance or regulation?YES_NO
13.Will lot be re-graded?YES_NO ✓Will excess fill be removed from premises?YES_NO✓'
14.Names of Owner of premises If ATY kew5Agi1lfAW&ddress Phone No.201"`1(3- 8$M
Name of Architect Address Phone No
Name of Contractor-"W tW C--rtoss Address 170 w.lbwt P( Phone No. 431-21 1- '1104
A4em,,ot " 117)Pv
15 a.Is this property within 100 feet of a tidal wetland or a freshwater wetland?*YES NO we-
IF YES,SOUTHOLD TOWN TRUSTEES&D.E.C.PERMITS MAY BE REQUIRED.
b.Is this property within 300 feet of a tidal wetland?*YES NO
*IF YES,D.E.C.PERMITS MAY BE REQUIRED.
16.Provide survey,to scale,with accurate foundation plan and distances to property lines.
17.If elevation at any point on property is at 10 feet or below,must provide topographical data on survey.
18.Are there any covenants and restrictions with respect to this property?*YES NO ✓
*IF YES,PROVIDE A COPY.
STATE OF NEW YORK)
SS:
COUNTY OF )
i being duly swom,deposes and says that(s)he is the applicant
(Name of individual signing contract)above named,
o
N S)He is the Com c 4rc.0_
t s (Contractor,Agent,Corporate Officer,etc.)
g�vz°
of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;
n that all statements contained in this application are true to the best of his knowledge and belief;and that the work will be
F rn au performed in the manner set forth in the application filed therewith.
� CD r
t y
Sworn to before me s
~ W E day of r 20_L-21_
p E
Notary Public Signature of A
OF
vt
J�-�A X 1 k4V A, A
.o.
MM
I k 512
• Di IR gig v',A WrIle
YK
R
N R
Sao
SC.T.M.Na ow w-,.low SECTIL t., BLW-J LUT(3;.d5
F
YICANlT DWELL
CL r."
:- n 3679
,00 R 00 f.1.172 � 1 a�' �� IL
Lp a jw
own 1w
( ti
1 v+»
ewi ,u-+• ar
r'
Wi 57 I/.+._�-ad�1 MME UA
al•. nN �' R�O 1
`� f1 RttA
a.
d Amm mu 0
n LOT c
L LOT 5 N
11 ��
VACANT
nix 41A
win
A 6 1yp
sow
maw A"olrs r
o y1q
ms Z
>b OPEN SPACE
•�.,a g VACANT
• •10#I • NOTE:VKDE UMITIES
TF1E NAM SUPPLY, 11ELES AM CESSPOOL
LOCAX"SMOMN ARE FROM FXLD OMRWft MS
AND M DAFA COTAV"FROM OWft
AREA: 40AW S.F. OR 0.92 ACRES EYEYAIIDM DARJ,M: aSMIUM -------------
r L.uuTTwtPTtEO ALTERAT/dY Dw ADOIAOM TG ssas SuRLEY rs A VtO:ATlOM OF•sscrlaM�z�D� n+c Hcw rorarc STATE EOUCANON tAw. LxwES aF TNts saalcY
LbW NOF LfANM jW LAND Stn WVW5 fM6QSM SEAL SHALL NOT N GOHSOERED TO HE A YAW TRUE COPY. CUARANIEES#JMAIM HEREON SHALL ftW
agr M pe pERWN MR WOW IW S Wr 15 FNEPARE4 AND LA!HIS SOMF TO THE ME COWAIM,, COPE M ENrAL AGENCY AND LE>w014 eMSATWTON
LISTED MAMQK AAO FO PC ASJKXts3 Or THE W474&SNIUT:OM,WARAMTPES ARE NOT MANSMASLE
TMC Qqwm or amonow pow Hamm FROII W P.-,CWRTY LW.5 M THE S`MUCRM0 ARE FIX A SPEOFIC#"JW SE AND USY THEREFORE MY ARE
Nor oY1D10ED TO&VAVIKW W ppo MY Lies CM N'am Aw EMMON OF FENX-. AODfXWAL MUMMS M AND OA/ER mFWOY WvM EA5EA4WFS
MIDAW MOSUMAM S11 uc'LNE3 AECdIM OR UWGDMW!',T 510.'4::NAAN$ED UNLESS PNTMULY EVIDENT OM FW PRAMSE^S A THE A4E QF SURVEY
1
suRYtr OR LOTS CERTIFIED TO: PETE ofN
MAP OFt CHARDOW4AY WOODS AT SOUTHOLD
Htut
SITUAIM AL• SoUrp.DLD
Taw OF:SO(lTkWD ggNNIM M. 111DYCHm I.S.
VJFFOLK CMNTY• NEW YORK ` ', (aaa awmaw as a" Dedin
Y.O. Du S. )last tusk. Mw York. 11068
�'t28—sw wmx i-40, at�E:GC'r 25. 21x5 raoKt(al)ftd ajw FAX
(as)s�-tw
f
s
Models: 14/20RESAL
KOHLER.POWER SYSTEMS Must Gas
LPG/Natures! Gas
a�� was ism
CrC)9Otl1 Standard Features
1 C.
�iPCJr4f�R"'.04 T �• • DC2 Controller
NATIOttAIIY REGISTERED '71 c One digital controller manages both the generator set
and Model RXT transfer switch functions
Designed for today's most sophisticated electronics.
c Electronic speed control responds quickly to varying
household demand
c Digital voltage regulation protects your sensitive
electronics from harmonic distortion and unstable power
quality
` c Two-line,backlit LCD display is easy to read,even in
direct sunlight or low light
• Kohler Command PRO Engine Features
c Kohler Command PROV OHV engine with hydraulic
valve lifters for reliable performance without routine
valve adjustment or lengthy break-in requirements
c Powerful, reliable air-cooled performance
The Kohler Advantage c Simple field conversion between natural gas and LPG
fuels while maintaining emission certification
• High Quality Power • Designed for Easy Installation
Kohler home generators provide advanced voltage and c polymer base eliminates the need for a concrete
frequency regulation along with Ultra-low levels of
harmonic distortion for excellent generator pourer quality to mounting pad, reducing installation time and cost
protect your valuable electronics. Hinged,locking roof
• Extraordinary Reliability c Fuel and electrical connections through the enclosure
Kohler is known for extraordinary reliability and wall eliminate the need for stub-ups through the bottom
performance and backs that up with an industry-leading c' Load connection terminal block allows easy field wiring
5-year or 2000 hour warranty. c; Designed for outdoor installation only
• Powerful Performance + Model RXT Transfer Switch
Exclusive PowerBoost"' technology provides excellent c Select 100 amp RXT ATS with load center and NEMA 1
starting power. The Kohler 14 kW generator can easily steel enclosure or 200 amp standard RXT ATS with
start and run a 5 ton air conditioner.* NEMA 3R aluminum enclosure
• Corrosion-Proof Enclosure c See page 4 for more information
The bold new Kohler design is completely corrosion proof, + Certifications
even in harsh seaside environments,and is c Meets emission regulations for CA 2011 and later LSI
impact-resistant even at-34° C(-30° F). engines(14RESAL only)and U.S.Environmental
• Fast Response Protection Agency(EPA)phase 2 small off-road engines
Kohler's unique Fast-Response excitation system with both LPG and natural gas
delivers excellent voltage response and short-circuit c UL 2200 listed(60 Hz model)
capability. c CSA certification available(60 Hz model)
• Quiet Operation c Approved for stationary standby applications in locations
Kohler home generators provide quiet,neighborhood- served by a reliable utility source
friendly performance. c Model 14RESAL is also approved for non-standby
(off-grid)applications (18 month or 1000 hour warranty
applies for non-standby applications)
Generator Ratings
Standby Ratings
Natural Gas LPG
Model Voftage Phase Hz Alternator kw/kVA Amps I(W/kVA Amps
14RESAL 120/240 i_ 60 2175 12/12 50.0 14/14 58.3
20RESAL 1201240 Ml _ _ 60 2177 18/18 75.0 20120 83.3
RAM'N GS•Standby rat'.ngsappi yt oinste."atials served byareiiet:eut-1 ysourre.All single•pheseunitsa,e rated all.0p uxtrtactor.Thestandbyratngisap f:FcabfetovadaVeloads-k^h an average
load factor of 805',for the duration of the pc.l.^.r outage.t.o oYedoad eapadlyis sped"ed al this rating.Ratings are in accordonre vMh 4SO-3046/1,BS5514,AS2789,and DIN 6271.GENERAL
GUIDELINES FOR DERATING:ALTITUDE:Derain 4".par305m(10001!.)etavahon above 153 m(500 f1.).TEMPERATURE:Derate23.per 5.5'C(10'F)temperature increase above 16'C(80=F)
AvaBa4 tyissuliecttoctlwgaw;lhoutnctee Thegenaralar set m:,nutr ct urer reserves the«giii tochaogethede_kgnorspec:!_+ions thoulno!,ce and.yZt wut any oVgationor6�s:y%vhatsoever.
Contact your local Kohler Co.generator Cishibutor for ava'ab,,y
Chack the apF ance manufacturer's spec!'-:al"+ons for actual pcs ar reciorem?nis. Consu't a Kchla,'Pe;.ar Systems profsssionaf to caIcu,14ts your exact resideM!al pcver slstem
requirements.
G4-210 (14/20RESAL) 10/12c
Alternator Specifications
Alternator Specifications Alternator features
PovrerBoas Generator
Specifications 1-Phase . Compliance with NEMA, IEEE,and ANSI standards for
Manufacturer Kohler temperature rise
Output reconnectable 120/240 • Self-ventilated and dripproof construction
Type 2-Pole,Rotating Field a Vacuum-impregnated windings with fungus-resistant
Leads,quantity 4 epoxy varnish for dependability and long life
Voltage regulator Digital a Superior voltage waveform and minimum harmonic
Insulation: NEMA MG1-1.66 distortion from skewed alternator construction
Material Class H a Digital voltage regulator with+1.0%no-load to full load
Temperature rise Class H RMS regulation
Bearing:quantity,type 1,Sealed Sall • Rotating-field alternator with static exciter for excellent
Coupling Direct load response
Amortisseur windings Full
Voltage regulation,no-load to full-load
RkS
One-step load acceptance 100%of Rating
Peak motor starting WA @ 240 V:
14RESAL 35
20RESAL 40.5
Application Data
Engine Engine Electrical
Engine Specifications 14RESAL 20RESAL Engine Electrical System 14RESAL 20RESAL
Manufacturer Kohler Ignition system Electronic,
Engine:model,type CH740 CH1000 Capacitive Discharge
4-Cycle 4-Cycle Starter motor rated voltage (DC) 12
Cylinder arrangement V-2 Battery(purchased separately):
Displacement,cm3(cu.in.) 725(44) 999(61) Ground Negative
Bore and stroke,ntm(in.) 83 x 67 90 x 78.5 Volts(DC) 12
(3.27 x 2.64) (3.54 x 3.1) Battery quantity 1
Compression ratio 9:1 8.8:1 Recommended cold cranking amps:
Main bearings:quantity,type 2,Parent Material (CCA)rating for-18'C(0'F) 500
Rated RPM 3600 Group size 51
Max.engine povrer at rated rpm,kW(HP)
LPG,60 Hz 17.6(23.6) 23.0(30.9) Lubrication
Natural gas,60 Hz 15.3(20.5) 20.2(27.1) Lubricating System 14RESAL 20RESAL
Cylinder head material Aluminum Type Full Pressure
Valve material Steel/Steilite- Oil capacity(with filter),L(qt.) 1.9(2.0) 2.8(3.0)
Piston type and material Aluminum Alloy Oil filter:quantity,type 1,Cartridge
Crankshaft material Heat Treated,Ductile Iron Oil cooler Integral
Governor:type Electronic
Frequency regulation,no load to full load isochronous Fuel Pipe Size
Frequency regulation,steady state m0.5% Minimum Gas Pipe Size Recommendation,in,NPT
Air cleaner type Dry 14RESAL 20RESAL
Exhaust Natural Natural
Pipe Gas LPG Gas LPG
Exhaust System 14RESAL 20RESAL Length, 193,000 203,000 281,000 340,000
Exhaust temperature exiting the m(ft.) Btu/1r. Btu/hr Btu/hr. Btu/hr.
enclosure at rated kW,dry, °C(°F) 260(500) 8 (25) 3/4 3/4 1 3/4
15 (50) 1 3/4 1 1
30(100) 1 1 1 1/4 1
46(150) 1 1/4 1 1 1/4 1 1/4
61 (200) 1 1/4 1 1 1/4 1 114
G4-210 tral20RESA1-I 10112c
Fuel Requirements DC2 Controller
Fuel System 14RESAL 20RESAL
Fuel types Natural Gas or LPG /
Fuel supply inlet 1/2 NPT
Fuel supply pressure,kPa(in.H20): xx�
Natural gas 1.2-2.7(5-11)
Fuel Composition Limits* Nat.Gas LPG av x so FM Methane,%by volume(minimum) 90 min. --•
Ethane,%by volume(maximum) 4.0 max. - The DC2 controller provides integrated control for the generator
Propane,%by volume 1.0 max. 85 min. set,Kohler Model RXT transfer switch, programmable inter-
Propene,%by volume(maximum) 0.1 max. 5.0 max. face module(PIM),and load control module (LCM)
C4 and higher,%by volume 0.3 max. 2.5 max.
Sulfur,ppm mass(maximum) 25 max. The DC2 controller's 2-line LCD display provides a clear,
Lower heating value, easy-to-read display of status messages even in direct sunlight
MJ/m3(Btu/ft-3),min. 33 2(890) 84.2(2260) or low light.
* Contact your local distributor for suitability and rating derates based D � Controller Features
on fuel compositions outside these limits.
• OFF,AUTO,RUN,and EXERCISE pushbuttons
Operation Requirements 0 LED indicators for OFF,AUTO,RUN,and EXERCISE modes
Fuel Consumption Fuel Consumption,m3/hr.(cth) • LCD display:
Fuel Type %Load 14RESAL 20RESAL c Two lines x 16 characters per line
100 5.4 (193) 8.0 (281) c Backlit display with adjustable contrast for excellent
75 4.7 (163) 6.9 (243) visibility
Natural Gas 50 3.5 (124) 4.6 (161) • Scrolling system status display
25 2.6 (93) 3.6 (127) c Generator set status
_Exercise Voltage and frequency_ 1.7 (60) 2.0 (71) c Engine temperature
100 2.3 (81) 3,9 (136) c Oil pressure
75 2.1 (75) 3.1 (109) c Battery voltage
LPG 50 1.8 (60) 2.3 (82) c Engine runtime hours
25 1.2 (45) 1.7 (59) c Maintenance reminders
Exercise 0.8 (30) 1.0 (35) c OnCueO status (connected/disconnected)
Nominal fuel rating: Natural gas: 37 MJ/m3(1000 Btu/ft.3) • Date and time displays
LPG: 93 MJ/m3(2500 Btu/113) • Smart engine cooldown senses engine temperature
LPG conversion factors: 8.58 ft.3-1 lb. a Digital isochronous governor to maintain steady-state speed
0.535 m3=1 kg at all Toads
36.39 ft. -i gal.
* Digital voltage regulation: ±1.0%RMS no-load to full-load
* Automatic start with programmed cranking cycle
Sound Data * Exercise modes
Model 14RESAL sound level is 63 dBA during weekly engine c Unloaded weekly exercise with complete system
exercise and 67 dBA during full-speed generator diagnostics diagnostics
and normal operation. c Unloaded full-speed exercise
c Loaded full-speed exercise (Model RXT ATS required)
Model 20RESAL sound level is 64 dBA during weekly engine • Front-access min!USB connector for SiteTech connection
exercise and 69 dBA during full-speed generator diagnostics
and normal operation. . Front access mini breaker protects the alternator
• integral Ethernet connector for KohlerO OnCueo
All sound levels are measured at 7 meters with no load. * Built-in 2.5 amp battery charger
* Remote two-wire start/stop capability for optional connection
of Model RDT or RSB transfer switches
* Diagnostic messages
c Displays diagnostic messages for the engine,generator
set,model RXT transfer switch,and optional
programmable interface module(PIM)and load control
module(LCM)
Over 70 diagnostic messages can be displayed
• A laptop computer and Kohlero SiteTech"- software can be
used to change system settings or upgrade controller
firmware
G4.210 (14 120RESAL) 10/12c
KOHLER CO.,Kohler,Wisconsin 53044 USA Kohler Power Systems
Phone 920-457-4441,Fax 920-459-1646 Asia Pacific Headquarters
For the nearest sales and service outlet in the 7 Jurong Pier Road
US and Canada,phone 1-800-544-2444 Singapore 619159
KohlerPowercom Phone(65)6264-6422,Fax(65)6264-6455
Standard Generator Set Features Model RXT Transfer Switch
• ATS:Model RXT automatic transfer switch
• Battery cables ;
• Braided stainless steel flexible fuel line ; f
® CARB(14RESAL only)and EPA-certified fuel system )
® Corrosion-proof polymer sound enclosure a
• Critical silencer ,
• DC2 generator set/ATS controller
• Field-connection terminal block
• Fuel solenoid valve and secondary regulator
• Line circuit breaker:
14RESAL: 70 amps
20RESAL: 100 amps 200 Amp at optional
status indicator shown.
• Multi-fuel system,LPG/natural gas,field-convertible
• Oil drain extension with shutoff valve • UL listed
• Premium 5-year limited warranty • 240 VAC/60 Hz
• 18-month limited warranty for non-standby(off-grid) • Withstand rating 10,000 amps with specified breakers
applications(14RESAL only) • The following transfer switch models are now available with
• Rodent-resistant construction the 14RESAL and 20RESAL:
• Sound-deadening,flame-retardant foam per UL 94, c 100 amp RXT with load center and NEMA 1 steel
class HF-1 enclosure for indoor installation
C 200 amp standard RXT with corrosion-resistant NEMA 3R
Available Accessories* aluminum enclosure for indoor or Outdoor installation
o Designed for use only with Kohler generator sets equipped
Communication Accessories with the RDC2 or DC2 controller
OnCue 'Generator Management System o See Specification Sheet G11-121 for more information
Controller Accessories
.-] Programmable Interface Module(PIM)
(provides 2 digital inputs and 6 relay outputs) Generator Set Dimensions and Weights
Load Control Module (LCM)
(provides 4 power relays and 2 HVAC relays) Overall Size,L x W x H: 1216 x 665 x 733 mm
(48 x 26.2 x 29 in.)
Electrical System Shipping Weight(with RXT ATS):
Z] Battery 14RESAL w/i 00 amp RXT ATS 216 kg(476 lb.)
14RESAL tit/200 amp RXT ATS 212 kg(467 lb.)
,] Battery heater 20RESAL tv/100 amp RXT ATS 268 kg(590 lb.)
Maintenance 20RESAL w/200 amp RXT ATS 263 kg (580 lb.)
Maintenance kit(air and oil filters) ---- - L
General maintenance literature kit
Overhaul literature kit
Production literature kit H
Starting Aids I
Carburetor heater, 120 VAC(recommended for - - -
reliable starting at temperatures below 0°C[32°F]) W
regulator heater ad 20RESAL recommended for
1:01P Usnemons are pra.-.ded for reference on:r and should not be used for g!anr+lg
Fuel re
g pad insta."allon.Contact Vow local Wstributor for more dela'+ed informalion.
reliable starting at temperatures below-i8°C[0°F])
DISTRIBUTED BV:
l3XT Transfer Switch Accessories
Status indicator
Miscellaneous Accessories
* Accessories are available through Kohler authorized distributors and
dealers.
2071.2012 by Kot!sr Co.P!f ri,hts reserved
G4-210 (14120RESAL) 10112c
KOHLER CO. CONFIDENTIAL INFORMATION
7
L-3
4
-WytK tom['
PRINT,',.,
ADV-B424 D
JUne 06, 20 i2- PRODUCTION RELEASED-UNCONTROLLIED WHEN PRINTED
Cl)
C0
m (D
7
4 I 3
CD
:3
0 Cl) 10 S I RUC TURF C."ID STRUC
TURI
OCCU,'ItO STRUCTURE
0
",CE DOOR
J,
0:)
SET
c C
CD r 7 KVICE DOOR SET
,.ET
SERVIC.g cook
AR n I 4 FT. 6.4,I TIED AT EXHAUST M En
l'.
wAli15 SIDES
OISTAN'_ -0
AWN FURNITURr
SENSITIVE PLANTS.'E%.
ACCWrAKS
ya I EXHAUST IS AIMED AWAY Oft VARAL-CL TO S'RL4TtRL
C
I EXHAUST EIS 1407CMIRC IED AT PLAY ARIAS. PATIOS 01
OTEAAR AS WN'IF PEOPLE CCKRESAT-
3) TW"NEAREST W19W VENT. DOOR 04 'IPIL0 ;VAuCl R-�
c" w IN S AT LEAST 5 FEET ra"THE EXIA�Ig, _g?6-TI.E SET.
P 0 R
F"EFERFAM .E RECOYNEVDED 0 STANCE FROM.A 4) SET MR: a PC OFFSET FROA STRUCTURE
S r UC.0 I E S DEP-111011ir ON STATE AND
1) VAIAUST 15 COMPLETELY AIMED AWAY FROM TrE STR9CYUAE. ,OICAL CC , 37. STANDARD 5) WINDOWS &OMS ON ADJACENT�,WLS ARIF C_OS',Q
-..a-N-"2zA"`Lk6 ON AM,,at 05
2) EX4'UST 'S,00-DthrC-,CD AT PLAY WAS, PATIOS OR OTHER S-AT OMARY"COMM,"1011 E46 MES F s) rublACC AND OTHER S19110, INTAIISS ARE AT LC,3T 0 FEE?
AZ,-13 WHER, P EXHAUST(ID OF SET,
PEOPLE C0146"GATE. hr3 GAS TLRB NES. STATES TH,11.
DISTANCE SVW D OF AT LEAST 5 rFET
3) ViE 9EA-CST WlhOCW. VENT, DOOR CA S!MILAR FROM A CONSUNOLC MATERIAL. TO'? I) W'EO BARRIER AND 3 INCH TiCx Q:Avf;.4ASr IC,;AYC0 TO FRV01-
O+,-N-I,G :S AT�,EA.-r S r;dT FROP TAE EXHAUST CK)OF THC SET INS Ii ALLA IONS MCA!NOR•COMRUST;0LE GRASS& OS FROM GROWHIO TOO C_OSL�O-,!C SET
IMYER AI 8E SUR! to LEAVE A M I
4) SET 4AS 7ROPER OFFSET Ff-'.O-.STRUCTURE M'N;Ulg�!S-AVCF OF 3 FEET-0 ENS.,F_= 0) NO PFLAHIS, SHAUSS OR 074EM COWSUIT'QiES t,,OVtD I
S) 1,RDOWS&:K)CR$ON ADJACENT WAI.L. ARE CLOSED.
PROPER GENCRA�OR COG�llfr, GRAVEL AREA
i) SCVS�T vr,PLANTS. PATIO PUP0 T�4RE. ETC. ARE AT !CAST 0 FEET FROM
6) FUPIACE IRO OTHCH S!KILAI 'WAKES ARC AT LEAST 10 rti!T FROM CX NA ST NO Of SET
,XL-S-, V13 OF SET. 10) REFER TO OWNCRS MANUAL FOR OTME! ;4S'A_LAT!0H COUSTRA NT3.
A ',;'Cl BA"'-R AN3 3 MEN GRAVEL W-, ;OCAYED TO 1`8,VCH- ,A
GiAiS A W-EDS FROM GROW liG-00,CLOSE TO'If:! SET 4--ft wi. a w W.-un. P ulmtr I
9) NO PLANTS' SHRUDS 00 OTNEII COMQ�j3'70LES A-LOW'D 19
CnA.'.. AR'A
,. _
si SE7,31;TIV6,1LA�11S�,PATIO rugu,-,IRE, ETC ARE AT EAST 8 FEET FROM
:0) RE-El TO OW,M MANUAL OF 074EN INSTALLATION CONST4;A MTN
".At) E, 0, 5-
W2W*SA
0) AnV-%6
co B T c 5 4
10 kW Propane generator
MUtility
Generator feeder-(3)#6 type THHN,+
(1)#8 type THHN equip gnd.
Charging circuit-(3)#14 THHN in 1"
EMT(or uivalent)
100 amp 10 kw
2 pole 100 amp 16 Circuit ------------ --------- propane
ATS Subpanel ATS generator
Breaker
Existing
Main
Building distribution
Grounding panel
Electrode Mazn 2�p` Control circuit,
1812 twisted pair
in free air
(12)#14 THHN,(8)#12
THHN,(3)#2 THHN,(1)#4
THHN EGC in 1"Metal Flex
(or equivalent)
Roof Diagnostics Solar&Electric,LLC. Katy Konstantaras Residence
One Line Electric Diagram 835 Chablis Path, Southold,NY 11971
Generator Installation lOkW LP Stand-by Generator
Phone: 732.974.8874 Date: 12/16/2013
10 kW ProDane aenerator
Propane Existing Gas Line into
Tank the home or equipment
P -----------------------------------------------r
(30') - 1"Poly Pipe 1/2" Flexible Gas
underground with Pipe
trace wire.
Generator Gas
Shut off Valve
Roof Diagnostics Solar&Electric,LLC. Katy Konstantaras Residence
Plumbing Riser Diagram 835 Chablis Path, Southold,NY 11971
Generator Installation 1OkW LP Stand-by Generator
Phone: 732.974.8874 Date: 12/16/2013