Loading...
HomeMy WebLinkAbout38636-Z Town of Southold Annex 5/8/2014 P.O.Box 1179 54375 Main Road Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 36903 Date: 5/8/2014 THIS CERTIFIES that the building GENERATOR Location of Property: 115 Chardonnay Dr, Southold, SCTM#: 473889 Sec/Block/Lot: 51.-3-3.5 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this officed dated 12/31/2013 pursuant to which Building Permit No. 38636 dated 1/23/2014 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: ACCESSORY GENERATOR AS APPLIED FOR The certificate is issued to Konstantaras,Katy (OWNER) of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 38636 05-07-2014 PLUMBERS CERTIFICATION DATED Authorized Signature TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE � �' SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 38636 Date: 1/23/2014 Permission is hereby granted to: Konstantaras, Katy 835 Chablis Path Southold, NY 11971 To: install an Accessory Generator as applied for At premises located at: 115 Chardonnay Dr, Southold SCTM #473889 Sec/Block/Lot# 51.-3-3.5 Pursuant to application dated 12/31/2013 and approved by the Building Inspector. To expire on 7/25/2015. Fees: ACCESSORY $100.00 ELECTRIC $85.00 CO -ALTERATION TO DWELLING $50.00 Total: $235.00 Building Inspector Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings,property lines, streets,and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal(S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1%lead. 5. Commercial building,industrial building,multiple residences and similar buildings and installations,a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings(prior to April 9,1957)non-conforming uses,or buildings and"pre-existing"land uses: 1. Accurate survey of property showing all property lines,streets,building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant.If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00,Alterations to dwelling$50.00, Swimming pool$50.00,Accessory building$50.00,Additions to accessory building$50.00,Businesses$50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy-$.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy-Residential$15.00,Commercial$15.00 Date. New Construction: Old or Pre-existing Building: i/ (check one) Location of Property: $vZ,:� C RA61 IS- Ph+1k &-Z46"�Ajj 1 House No. Street Hamlet Owner or Owners of Property: '1 y �ONS�A N`�792FcS Suffolk County Tax Map No 1000, Section Block Lot S-- Subdivision Filed Map. Lot: Permit No. Date of Permit. Applicant: Health Dept.Approval: Underwriters Approval: Planning Board Approval: Request for: Temporary Certificate Final Certificate: (check one) Fee Submitted: $ Applic a pF SO(/l,�ol Town Hall Annex Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 1179 rog er.riche rt(a-town.Southold.ny.us Southold,NY 11971-0959 c4UNT1,� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION Issued To: Katy Konstantaras Address: 115 Chardonnay Dr (835 Chablis Path) City: Southold St: NY Zip: 11971 Building Permit#: 38636 Section: 51 Block: 3 Lot: 3.5 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: Roof Diagnostics License No: 34280-me SITE DETAILS Office Use Only Residential X Indoor X Basement X Service Only Commerical Outdoor X 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures HID Fixtures Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Fluorescent Fixture Pumps Transformer Appliances Dryer Recpt Emergency Fixture Time Clocks Disconnect Switches Twist Lock Exit Fixtures TVSS Other Equipment: installation of 10KW standby generator with 100a transfer switch Notes: Inspector Signature: Date: May 7 2014 81-Cert Electrical Compliance Form.xls Of SObly�� � 'IF C 'b TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ } FOUNDATION 1ST [ } ROUGH PLUMBING [ J FOUNDATION 2ND [ ] INSULATION [ J FRAMING / STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] CAULKING REMARKS: DATE 1 INSPECTOR t FIELD Ilv3PE N 18ORT DATE COMMENTS b FOUNDATION(1ST) V.1 FOUNDATION(ZND) ROUGH FRAMINQ& PLUMBING d S INSULATION PER N.Y. H STATE ENERGY CODE FINAL ADDITIONAL COMMENTS ,460- U �rn TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD,NY 11971 4 sets of Building Plans TEL:(631)765-1802 Planning Board approval FAX:(631)765-9502 3 Survey SoutholdTown.NorthFork.net PERMIT NO. V k R tic Form S.D.E.C. tees 1 d Permit Examined 1- 20 DEC 31 2013 co -Water Assessment Form Approved / L 20 Ma 1 to: Disapproved a/c R',.!)� TO"' U= rOLD Ph e: Expiration ) 20 2� Building Inspector APPLICATION FOR BUILDING PERMIT Date ,20 INSTRUCTIONS a.This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans,accurate plot plan to scale.Fee according to schedule. b.Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas,and waterways. c.The work covered by this application may not be commenced before issuance of Building Permit. d.Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant.Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f.Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date.If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize,in writing,the extension of the permit for an addition six months.Thereafter,a new pemtit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk County,New York,and other applicable Laws,Ordinances or Regulations,for the construction of buildings,additions,or alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code,housing code,and regulations,and to admit authorized inspectors on premises and in building for necessary inspections. (Signature o p t or name,if a corporation) 7,9 &, /,6v2 0/ .-5y Ae&P Offtdai� (Mailing address of applicant) c�iid'thi,�l1�)Sei� NQ-1 L L State whether applicant is owner,lessee;agent,architect,engineer,general contractor,el r CQru$2wr�'rca2 DATE. B.P. # Z Name of owner of premises KP%T O +pt W et R ES FEE: l cq BY (As on the tax roll or latest deldOTIFY BUILDING DEPARTNIE-�J1 If appli�ar�oration,sig0`a of duly authorized officer 765-1802 8 AM TO 4 PM FOR 1 f?, � FOLLOWING INSPECTIONS: ame and fftlWciorporate officer) 1. FOUNDATION TWO REQUIRED Builders License No. FOR POURED CONCRETE Plumbers License No. � gj'yS — M P 2. ROUGH-FRAMING,PLUMBING, Electricians License No.3YL$O _ A./� STRAPPING, ELECTRICAL&CAULKI^,I Other Trade's License No. 3. I� �10 h f-J-4'`'FINAL`IONSTRUCTION &ELECTRICA; 1. Lo tion of land on w 'ch proposed work will be done: 5 MUST BE COMPLETE FOR C.O. ON TION SHALL MEET THE House Number Street Hamlet r I D F N F�`,. \,'-,riK SATE. NOT RESPONSIBLE FOR County Tax Map No. 1000 Se n . Block 3 DES � pjt;;ONSTRUCTION ERRORS - . Subdivision In . > Filed Mai No. Lot 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy r✓//�► b. Intended use and occupan cy 3. Nature of work(check which applicable):New Building Addition Alteration Repair Removal Demolition Other Work��c xQ_ (Description) 4. Estimated Cost IT;Doo Fee (To be paid on filing this application) 5. If dwelling,number of dwelling units Number of dwelling units on each floor If garage, number of cars 2L 6. If business,commercial or mixed occupancy,specify nature and extent of each type of use. 7. Dimensions of existing structures,if any:Front Rear Depth Height Number of Stories Dimensions of same structure with alterations or additions: Front Rear Depth Height Number of Stories 8. Dimensions of entire new construction:Front Rear Depth Height Number of Stories 9. Size of lot:Front Rear Depth 10.Date of Purchase Name of Former Owner 11.Zone or use district in which premises are situated 12.Does proposed construction violate any zoning law,ordinance or regulation?YES_NO 13.Will lot be re-graded?YES_NO ✓Will excess fill be removed from premises?YES_NO✓' 14.Names of Owner of premises If ATY kew5Agi1lfAW&ddress Phone No.201"`1(3- 8$M Name of Architect Address Phone No Name of Contractor-"W tW C--rtoss Address 170 w.lbwt P( Phone No. 431-21 1- '1104 A4em,,ot " 117)Pv 15 a.Is this property within 100 feet of a tidal wetland or a freshwater wetland?*YES NO we- IF YES,SOUTHOLD TOWN TRUSTEES&D.E.C.PERMITS MAY BE REQUIRED. b.Is this property within 300 feet of a tidal wetland?*YES NO *IF YES,D.E.C.PERMITS MAY BE REQUIRED. 16.Provide survey,to scale,with accurate foundation plan and distances to property lines. 17.If elevation at any point on property is at 10 feet or below,must provide topographical data on survey. 18.Are there any covenants and restrictions with respect to this property?*YES NO ✓ *IF YES,PROVIDE A COPY. STATE OF NEW YORK) SS: COUNTY OF ) i being duly swom,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, o N S)He is the Com c 4rc.0_ t s (Contractor,Agent,Corporate Officer,etc.) g�vz° of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application; n that all statements contained in this application are true to the best of his knowledge and belief;and that the work will be F rn au performed in the manner set forth in the application filed therewith. � CD r t y Sworn to before me s ~ W E day of r 20_L-21_ p E Notary Public Signature of A OF vt J�-�A X 1 k4V A, A .o. MM I k 512 • Di IR gig v',A WrIle YK R N R Sao SC.T.M.Na ow w-,.low SECTIL t., BLW-J LUT(3;.d5 F YICANlT DWELL CL r." :- n 3679 ,00 R 00 f.1.172 � 1 a�' �� IL Lp a jw own 1w ( ti 1 v+» ewi ,u-+• ar r' Wi 57 I/.+._�-ad�1 MME UA al•. nN �' R�O 1 `� f1 RttA a. d Amm mu 0 n LOT c L LOT 5 N 11 �� VACANT nix 41A win A 6 1yp sow maw A"olrs r o y1q ms Z >b OPEN SPACE •�.,a g VACANT • •10#I • NOTE:VKDE UMITIES TF1E NAM SUPPLY, 11ELES AM CESSPOOL LOCAX"SMOMN ARE FROM FXLD OMRWft MS AND M DAFA COTAV"FROM OWft AREA: 40AW S.F. OR 0.92 ACRES EYEYAIIDM DARJ,M: aSMIUM ------------- r L.uuTTwtPTtEO ALTERAT/dY Dw ADOIAOM TG ssas SuRLEY rs A VtO:ATlOM OF•sscrlaM�z�D� n+c Hcw rorarc STATE EOUCANON tAw. LxwES aF TNts saalcY LbW NOF LfANM jW LAND Stn WVW5 fM6QSM SEAL SHALL NOT N GOHSOERED TO HE A YAW TRUE COPY. CUARANIEES#JMAIM HEREON SHALL ftW agr M pe pERWN MR WOW IW S Wr 15 FNEPARE4 AND LA!HIS SOMF TO THE ME COWAIM,, COPE M ENrAL AGENCY AND LE>w014 eMSATWTON LISTED MAMQK AAO FO PC ASJKXts3 Or THE W474&SNIUT:OM,WARAMTPES ARE NOT MANSMASLE TMC Qqwm or amonow pow Hamm FROII W P.-,CWRTY LW.5 M THE S`MUCRM0 ARE FIX A SPEOFIC#"JW SE AND USY THEREFORE MY ARE Nor oY1D10ED TO&VAVIKW W ppo MY Lies CM N'am Aw EMMON OF FENX-. AODfXWAL MUMMS M AND OA/ER mFWOY WvM EA5EA4WFS MIDAW MOSUMAM S11 uc'LNE3 AECdIM OR UWGDMW!',T 510.'4::NAAN$ED UNLESS PNTMULY EVIDENT OM FW PRAMSE^S A THE A4E QF SURVEY 1 suRYtr OR LOTS CERTIFIED TO: PETE ofN MAP OFt CHARDOW4AY WOODS AT SOUTHOLD Htut SITUAIM AL• SoUrp.DLD Taw OF:SO(lTkWD ggNNIM M. 111DYCHm I.S. VJFFOLK CMNTY• NEW YORK ` ', (aaa awmaw as a" Dedin Y.O. Du S. )last tusk. Mw York. 11068 �'t28—sw wmx i-40, at�E:GC'r 25. 21x5 raoKt(al)ftd ajw FAX (as)s�-tw f s Models: 14/20RESAL KOHLER.POWER SYSTEMS Must Gas LPG/Natures! Gas a�� was ism CrC)9Otl1 Standard Features 1 C. �iPCJr4f�R"'.04 T �• • DC2 Controller NATIOttAIIY REGISTERED '71 c One digital controller manages both the generator set and Model RXT transfer switch functions Designed for today's most sophisticated electronics. c Electronic speed control responds quickly to varying household demand c Digital voltage regulation protects your sensitive electronics from harmonic distortion and unstable power quality ` c Two-line,backlit LCD display is easy to read,even in direct sunlight or low light • Kohler Command PRO Engine Features c Kohler Command PROV OHV engine with hydraulic valve lifters for reliable performance without routine valve adjustment or lengthy break-in requirements c Powerful, reliable air-cooled performance The Kohler Advantage c Simple field conversion between natural gas and LPG fuels while maintaining emission certification • High Quality Power • Designed for Easy Installation Kohler home generators provide advanced voltage and c polymer base eliminates the need for a concrete frequency regulation along with Ultra-low levels of harmonic distortion for excellent generator pourer quality to mounting pad, reducing installation time and cost protect your valuable electronics. Hinged,locking roof • Extraordinary Reliability c Fuel and electrical connections through the enclosure Kohler is known for extraordinary reliability and wall eliminate the need for stub-ups through the bottom performance and backs that up with an industry-leading c' Load connection terminal block allows easy field wiring 5-year or 2000 hour warranty. c; Designed for outdoor installation only • Powerful Performance + Model RXT Transfer Switch Exclusive PowerBoost"' technology provides excellent c Select 100 amp RXT ATS with load center and NEMA 1 starting power. The Kohler 14 kW generator can easily steel enclosure or 200 amp standard RXT ATS with start and run a 5 ton air conditioner.* NEMA 3R aluminum enclosure • Corrosion-Proof Enclosure c See page 4 for more information The bold new Kohler design is completely corrosion proof, + Certifications even in harsh seaside environments,and is c Meets emission regulations for CA 2011 and later LSI impact-resistant even at-34° C(-30° F). engines(14RESAL only)and U.S.Environmental • Fast Response Protection Agency(EPA)phase 2 small off-road engines Kohler's unique Fast-Response excitation system with both LPG and natural gas delivers excellent voltage response and short-circuit c UL 2200 listed(60 Hz model) capability. c CSA certification available(60 Hz model) • Quiet Operation c Approved for stationary standby applications in locations Kohler home generators provide quiet,neighborhood- served by a reliable utility source friendly performance. c Model 14RESAL is also approved for non-standby (off-grid)applications (18 month or 1000 hour warranty applies for non-standby applications) Generator Ratings Standby Ratings Natural Gas LPG Model Voftage Phase Hz Alternator kw/kVA Amps I(W/kVA Amps 14RESAL 120/240 i_ 60 2175 12/12 50.0 14/14 58.3 20RESAL 1201240 Ml _ _ 60 2177 18/18 75.0 20120 83.3 RAM'N GS•Standby rat'.ngsappi yt oinste."atials served byareiiet:eut-1 ysourre.All single•pheseunitsa,e rated all.0p uxtrtactor.Thestandbyratngisap f:FcabfetovadaVeloads-k^h an average load factor of 805',for the duration of the pc.l.^.r outage.t.o oYedoad eapadlyis sped"ed al this rating.Ratings are in accordonre vMh 4SO-3046/1,BS5514,AS2789,and DIN 6271.GENERAL GUIDELINES FOR DERATING:ALTITUDE:Derain 4".par305m(10001!.)etavahon above 153 m(500 f1.).TEMPERATURE:Derate23.per 5.5'C(10'F)temperature increase above 16'C(80=F) AvaBa4 tyissuliecttoctlwgaw;lhoutnctee Thegenaralar set m:,nutr ct urer reserves the«giii tochaogethede_kgnorspec:!_+ions thoulno!,ce and.yZt wut any oVgationor6�s:y%vhatsoever. Contact your local Kohler Co.generator Cishibutor for ava'ab,,y Chack the apF ance manufacturer's spec!'-:al"+ons for actual pcs ar reciorem?nis. Consu't a Kchla,'Pe;.ar Systems profsssionaf to caIcu,14ts your exact resideM!al pcver slstem requirements. G4-210 (14/20RESAL) 10/12c Alternator Specifications Alternator Specifications Alternator features PovrerBoas Generator Specifications 1-Phase . Compliance with NEMA, IEEE,and ANSI standards for Manufacturer Kohler temperature rise Output reconnectable 120/240 • Self-ventilated and dripproof construction Type 2-Pole,Rotating Field a Vacuum-impregnated windings with fungus-resistant Leads,quantity 4 epoxy varnish for dependability and long life Voltage regulator Digital a Superior voltage waveform and minimum harmonic Insulation: NEMA MG1-1.66 distortion from skewed alternator construction Material Class H a Digital voltage regulator with+1.0%no-load to full load Temperature rise Class H RMS regulation Bearing:quantity,type 1,Sealed Sall • Rotating-field alternator with static exciter for excellent Coupling Direct load response Amortisseur windings Full Voltage regulation,no-load to full-load RkS One-step load acceptance 100%of Rating Peak motor starting WA @ 240 V: 14RESAL 35 20RESAL 40.5 Application Data Engine Engine Electrical Engine Specifications 14RESAL 20RESAL Engine Electrical System 14RESAL 20RESAL Manufacturer Kohler Ignition system Electronic, Engine:model,type CH740 CH1000 Capacitive Discharge 4-Cycle 4-Cycle Starter motor rated voltage (DC) 12 Cylinder arrangement V-2 Battery(purchased separately): Displacement,cm3(cu.in.) 725(44) 999(61) Ground Negative Bore and stroke,ntm(in.) 83 x 67 90 x 78.5 Volts(DC) 12 (3.27 x 2.64) (3.54 x 3.1) Battery quantity 1 Compression ratio 9:1 8.8:1 Recommended cold cranking amps: Main bearings:quantity,type 2,Parent Material (CCA)rating for-18'C(0'F) 500 Rated RPM 3600 Group size 51 Max.engine povrer at rated rpm,kW(HP) LPG,60 Hz 17.6(23.6) 23.0(30.9) Lubrication Natural gas,60 Hz 15.3(20.5) 20.2(27.1) Lubricating System 14RESAL 20RESAL Cylinder head material Aluminum Type Full Pressure Valve material Steel/Steilite- Oil capacity(with filter),L(qt.) 1.9(2.0) 2.8(3.0) Piston type and material Aluminum Alloy Oil filter:quantity,type 1,Cartridge Crankshaft material Heat Treated,Ductile Iron Oil cooler Integral Governor:type Electronic Frequency regulation,no load to full load isochronous Fuel Pipe Size Frequency regulation,steady state m0.5% Minimum Gas Pipe Size Recommendation,in,NPT Air cleaner type Dry 14RESAL 20RESAL Exhaust Natural Natural Pipe Gas LPG Gas LPG Exhaust System 14RESAL 20RESAL Length, 193,000 203,000 281,000 340,000 Exhaust temperature exiting the m(ft.) Btu/1r. Btu/hr Btu/hr. Btu/hr. enclosure at rated kW,dry, °C(°F) 260(500) 8 (25) 3/4 3/4 1 3/4 15 (50) 1 3/4 1 1 30(100) 1 1 1 1/4 1 46(150) 1 1/4 1 1 1/4 1 1/4 61 (200) 1 1/4 1 1 1/4 1 114 G4-210 tral20RESA1-I 10112c Fuel Requirements DC2 Controller Fuel System 14RESAL 20RESAL Fuel types Natural Gas or LPG / Fuel supply inlet 1/2 NPT Fuel supply pressure,kPa(in.H20): xx� Natural gas 1.2-2.7(5-11) Fuel Composition Limits* Nat.Gas LPG av x so FM Methane,%by volume(minimum) 90 min. --• Ethane,%by volume(maximum) 4.0 max. - The DC2 controller provides integrated control for the generator Propane,%by volume 1.0 max. 85 min. set,Kohler Model RXT transfer switch, programmable inter- Propene,%by volume(maximum) 0.1 max. 5.0 max. face module(PIM),and load control module (LCM) C4 and higher,%by volume 0.3 max. 2.5 max. Sulfur,ppm mass(maximum) 25 max. The DC2 controller's 2-line LCD display provides a clear, Lower heating value, easy-to-read display of status messages even in direct sunlight MJ/m3(Btu/ft-3),min. 33 2(890) 84.2(2260) or low light. * Contact your local distributor for suitability and rating derates based D � Controller Features on fuel compositions outside these limits. • OFF,AUTO,RUN,and EXERCISE pushbuttons Operation Requirements 0 LED indicators for OFF,AUTO,RUN,and EXERCISE modes Fuel Consumption Fuel Consumption,m3/hr.(cth) • LCD display: Fuel Type %Load 14RESAL 20RESAL c Two lines x 16 characters per line 100 5.4 (193) 8.0 (281) c Backlit display with adjustable contrast for excellent 75 4.7 (163) 6.9 (243) visibility Natural Gas 50 3.5 (124) 4.6 (161) • Scrolling system status display 25 2.6 (93) 3.6 (127) c Generator set status _Exercise Voltage and frequency_ 1.7 (60) 2.0 (71) c Engine temperature 100 2.3 (81) 3,9 (136) c Oil pressure 75 2.1 (75) 3.1 (109) c Battery voltage LPG 50 1.8 (60) 2.3 (82) c Engine runtime hours 25 1.2 (45) 1.7 (59) c Maintenance reminders Exercise 0.8 (30) 1.0 (35) c OnCueO status (connected/disconnected) Nominal fuel rating: Natural gas: 37 MJ/m3(1000 Btu/ft.3) • Date and time displays LPG: 93 MJ/m3(2500 Btu/113) • Smart engine cooldown senses engine temperature LPG conversion factors: 8.58 ft.3-1 lb. a Digital isochronous governor to maintain steady-state speed 0.535 m3=1 kg at all Toads 36.39 ft. -i gal. * Digital voltage regulation: ±1.0%RMS no-load to full-load * Automatic start with programmed cranking cycle Sound Data * Exercise modes Model 14RESAL sound level is 63 dBA during weekly engine c Unloaded weekly exercise with complete system exercise and 67 dBA during full-speed generator diagnostics diagnostics and normal operation. c Unloaded full-speed exercise c Loaded full-speed exercise (Model RXT ATS required) Model 20RESAL sound level is 64 dBA during weekly engine • Front-access min!USB connector for SiteTech connection exercise and 69 dBA during full-speed generator diagnostics and normal operation. . Front access mini breaker protects the alternator • integral Ethernet connector for KohlerO OnCueo All sound levels are measured at 7 meters with no load. * Built-in 2.5 amp battery charger * Remote two-wire start/stop capability for optional connection of Model RDT or RSB transfer switches * Diagnostic messages c Displays diagnostic messages for the engine,generator set,model RXT transfer switch,and optional programmable interface module(PIM)and load control module(LCM) Over 70 diagnostic messages can be displayed • A laptop computer and Kohlero SiteTech"- software can be used to change system settings or upgrade controller firmware G4.210 (14 120RESAL) 10/12c KOHLER CO.,Kohler,Wisconsin 53044 USA Kohler Power Systems Phone 920-457-4441,Fax 920-459-1646 Asia Pacific Headquarters For the nearest sales and service outlet in the 7 Jurong Pier Road US and Canada,phone 1-800-544-2444 Singapore 619159 KohlerPowercom Phone(65)6264-6422,Fax(65)6264-6455 Standard Generator Set Features Model RXT Transfer Switch • ATS:Model RXT automatic transfer switch • Battery cables ; • Braided stainless steel flexible fuel line ; f ® CARB(14RESAL only)and EPA-certified fuel system ) ® Corrosion-proof polymer sound enclosure a • Critical silencer , • DC2 generator set/ATS controller • Field-connection terminal block • Fuel solenoid valve and secondary regulator • Line circuit breaker: 14RESAL: 70 amps 20RESAL: 100 amps 200 Amp at optional status indicator shown. • Multi-fuel system,LPG/natural gas,field-convertible • Oil drain extension with shutoff valve • UL listed • Premium 5-year limited warranty • 240 VAC/60 Hz • 18-month limited warranty for non-standby(off-grid) • Withstand rating 10,000 amps with specified breakers applications(14RESAL only) • The following transfer switch models are now available with • Rodent-resistant construction the 14RESAL and 20RESAL: • Sound-deadening,flame-retardant foam per UL 94, c 100 amp RXT with load center and NEMA 1 steel class HF-1 enclosure for indoor installation C 200 amp standard RXT with corrosion-resistant NEMA 3R Available Accessories* aluminum enclosure for indoor or Outdoor installation o Designed for use only with Kohler generator sets equipped Communication Accessories with the RDC2 or DC2 controller OnCue 'Generator Management System o See Specification Sheet G11-121 for more information Controller Accessories .-] Programmable Interface Module(PIM) (provides 2 digital inputs and 6 relay outputs) Generator Set Dimensions and Weights Load Control Module (LCM) (provides 4 power relays and 2 HVAC relays) Overall Size,L x W x H: 1216 x 665 x 733 mm (48 x 26.2 x 29 in.) Electrical System Shipping Weight(with RXT ATS): Z] Battery 14RESAL w/i 00 amp RXT ATS 216 kg(476 lb.) 14RESAL tit/200 amp RXT ATS 212 kg(467 lb.) ,] Battery heater 20RESAL tv/100 amp RXT ATS 268 kg(590 lb.) Maintenance 20RESAL w/200 amp RXT ATS 263 kg (580 lb.) Maintenance kit(air and oil filters) ---- - L General maintenance literature kit Overhaul literature kit Production literature kit H Starting Aids I Carburetor heater, 120 VAC(recommended for - - - reliable starting at temperatures below 0°C[32°F]) W regulator heater ad 20RESAL recommended for 1:01P Usnemons are pra.-.ded for reference on:r and should not be used for g!anr+lg Fuel re g pad insta."allon.Contact Vow local Wstributor for more dela'+ed informalion. reliable starting at temperatures below-i8°C[0°F]) DISTRIBUTED BV: l3XT Transfer Switch Accessories Status indicator Miscellaneous Accessories * Accessories are available through Kohler authorized distributors and dealers. 2071.2012 by Kot!sr Co.P!f ri,hts reserved G4-210 (14120RESAL) 10112c KOHLER CO. CONFIDENTIAL INFORMATION 7 L-3 4 -WytK tom[' PRINT,',., ADV-B424 D JUne 06, 20 i2- PRODUCTION RELEASED-UNCONTROLLIED WHEN PRINTED Cl) C0 m (D 7 4 I 3 CD :3 0 Cl) 10 S I RUC TURF C."ID STRUC TURI OCCU,'ItO STRUCTURE 0 ",CE DOOR J, 0:) SET c C CD r 7 KVICE DOOR SET ,.ET SERVIC.g cook AR n I 4 FT. 6.4,I TIED AT EXHAUST M En l'. wAli15 SIDES OISTAN'_ -0 AWN FURNITURr SENSITIVE PLANTS.'E%. ACCWrAKS ya I EXHAUST IS AIMED AWAY Oft VARAL-CL TO S'RL4TtRL C I EXHAUST EIS 1407CMIRC IED AT PLAY ARIAS. PATIOS 01 OTEAAR AS WN'IF PEOPLE CCKRESAT- 3) TW"NEAREST W19W VENT. DOOR 04 'IPIL0 ;VAuCl R-� c" w IN S AT LEAST 5 FEET ra"THE EXIA�Ig, _g?6-TI.E SET. P 0 R F"EFERFAM .E RECOYNEVDED 0 STANCE FROM.A 4) SET MR: a PC OFFSET FROA STRUCTURE S r UC.0 I E S DEP-111011ir ON STATE AND 1) VAIAUST 15 COMPLETELY AIMED AWAY FROM TrE STR9CYUAE. ,OICAL CC , 37. STANDARD 5) WINDOWS &OMS ON ADJACENT�,WLS ARIF C_OS',Q -..a-N-"2zA"`Lk6 ON AM,,at 05 2) EX4'UST 'S,00-DthrC-,CD AT PLAY WAS, PATIOS OR OTHER S-AT OMARY"COMM,"1011 E46 MES F s) rublACC AND OTHER S19110, INTAIISS ARE AT LC,3T 0 FEE? AZ,-13 WHER, P EXHAUST(ID OF SET, PEOPLE C0146"GATE. hr3 GAS TLRB NES. STATES TH,11. DISTANCE SVW D OF AT LEAST 5 rFET 3) ViE 9EA-CST WlhOCW. VENT, DOOR CA S!MILAR FROM A CONSUNOLC MATERIAL. TO'? I) W'EO BARRIER AND 3 INCH TiCx Q:Avf;.4ASr IC,;AYC0 TO FRV01- O+,-N-I,G :S AT�,EA.-r S r;dT FROP TAE EXHAUST CK)OF THC SET INS Ii ALLA IONS MCA!NOR•COMRUST;0LE GRASS& OS FROM GROWHIO TOO C_OSL�O-,!C SET IMYER AI 8E SUR! to LEAVE A M I 4) SET 4AS 7ROPER OFFSET Ff-'.O-.STRUCTURE M'N;Ulg�!S-AVCF OF 3 FEET-0 ENS.,F_= 0) NO PFLAHIS, SHAUSS OR 074EM COWSUIT'QiES t,,OVtD I S) 1,RDOWS&:K)CR$ON ADJACENT WAI.L. ARE CLOSED. PROPER GENCRA�OR COG�llfr, GRAVEL AREA i) SCVS�T vr,PLANTS. PATIO PUP0 T�4RE. ETC. ARE AT !CAST 0 FEET FROM 6) FUPIACE IRO OTHCH S!KILAI 'WAKES ARC AT LEAST 10 rti!T FROM CX NA ST NO Of SET ,X­L-S-, V13 OF SET. 10) REFER TO OWNCRS MANUAL FOR OTME! ;4S'A_LAT!0H COUSTRA NT3. A ',;'Cl BA"'-R AN3 3 MEN GRAVEL W-, ;OCAYED TO 1`8,VCH- ,A GiAiS A W-EDS FROM GROW liG-00,CLOSE TO'If:! SET 4--ft wi. a w W.-un. P ulmtr I 9) NO PLANTS' SHRUDS 00 OTNEII COMQ�j3'70LES A-LOW'D 19 CnA.'.. AR'A ,. _ si SE7,31;TIV6,1LA�11S�,PATIO rugu,-,IRE, ETC ARE AT EAST 8 FEET FROM :0) RE-El TO OW,­M MANUAL OF 074EN INSTALLATION CONST4;A MTN ".At) E, 0, 5- W2W*SA 0) AnV-%6 co B T c 5 4 10 kW Propane generator MUtility Generator feeder-(3)#6 type THHN,+ (1)#8 type THHN equip gnd. Charging circuit-(3)#14 THHN in 1" EMT(or uivalent) 100 amp 10 kw 2 pole 100 amp 16 Circuit ------------ --------- propane ATS Subpanel ATS generator Breaker Existing Main Building distribution Grounding panel Electrode Mazn 2�p` Control circuit, 1812 twisted pair in free air (12)#14 THHN,(8)#12 THHN,(3)#2 THHN,(1)#4 THHN EGC in 1"Metal Flex (or equivalent) Roof Diagnostics Solar&Electric,LLC. Katy Konstantaras Residence One Line Electric Diagram 835 Chablis Path, Southold,NY 11971 Generator Installation lOkW LP Stand-by Generator Phone: 732.974.8874 Date: 12/16/2013 10 kW ProDane aenerator Propane Existing Gas Line into Tank the home or equipment P -----------------------------------------------r (30') - 1"Poly Pipe 1/2" Flexible Gas underground with Pipe trace wire. Generator Gas Shut off Valve Roof Diagnostics Solar&Electric,LLC. Katy Konstantaras Residence Plumbing Riser Diagram 835 Chablis Path, Southold,NY 11971 Generator Installation 1OkW LP Stand-by Generator Phone: 732.974.8874 Date: 12/16/2013