Loading...
HomeMy WebLinkAbout38609-Z Town of Southold Annex 5/6/2014 P.O.Box 1179 54375 Main Road Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 36893 Date: 5/6/2014 THIS CERTIFIES that the building ADDITION/ALTERATION Location of Property: 195 Deerfoot Path, Cutchogue, SCTM#: 473889 Sec/Block/Lot: 97.-7-22 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this officed dated 12/17/2013 pursuant to which Building Permit No. 38609 dated 1/6/2014 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: ONE STORY ADDITION TO A SINGLE FAMILY RESIDENCE AS APPLIED FOR The certificate is issued to Occhipinti, Stephen&Klein,Anne (OWNER) of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 38609 04-30-2014 PLUMBERS CERTIFICATION DATED o ' i ture TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE SOUTHOLD, NY f BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 38609 Date: 1/6/2014 Permission is hereby granted to: Occhipinti, Stephen & Klein, Anne 267 Ridge Rd Douglaston, NY 11363 To: construct a one story addition as applied for At premises located at: 195 Deerfoot Path, Cutchogue SCTM # 473889 Sec/Block/Lot# 97.-7-22 Pursuant to application dated 12/17/2013 and approved by the Building Inspector. To expire on 7/8/2015. Fees: SINGLE FAMILY DWELLING -ADDITION OR ALTERATION $324.80 CO -ADDITION TO DWELLING $50.00 Total: $374.80 Building Inspector Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: I. Final survey of property with accurate location of all buildings,property lines, streets,and unusual natural or topographic features. 2. Final Approval from Health Dept.of water supply and sewerage-disposal (S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of I%lead. 5. Commercial building, industrial building,multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings(prior to April 9, 1957) non-conforming uses,or buildings and"pre-existing"land uses: 1. Accurate survey of property showing all property lines, streets,building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00,Alterations to dwelling$50.00, Swimming pool $50.00,Accessory building$50.00,Additions to accessory building$50.00, Businesses$50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy -$.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy- Residential $15.00, Commercial $15.00 Date. 12- 14- 201'6 New Construction: V Old or Pre-existing Building: (check one) Location of Property: 10 Derey: eT PAW e inkinqui House No. Street Hamlet Owner or Owners of Property: Pnwtsg itlLl� Suffolk County Tax Map No 1000, Section Block Lot 7-2 Subdivision M;sDSe COv'6 Filed Map. Lot: 44 Permit No. Date of Permit. Applicant: Health Dept. Approval: Underwriters Approval: Planning Board Approval: Request for: Temporary Certificate Final Certificate: (check one) Fee Submitted: $ Applican ture pF SOUlyolo Town Hall Annex Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 1179 roper.riche rt(aD-town.southold.ny.us Southold,NY 11971-0959Ol� �� �DUNT`I,N BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION Issued To: Occhipinti Address: 195 Deerfoot Path City: Cutchogue St: NY Zip: 11935 Building Permit#: 38609 Section: 97 Block: 7 Lot: 22 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: Roslak Electric Inc License No: 3677-me SITE DETAILS Office Use Only Residential X Indoor X Basement Service Only Commerical Outdoor 1st Floor X Pool New Renovation 2nd Floor Hot Tub Addition X Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt 6 Ceiling Fixtures HID Fixtures Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures 8 CO Detectors Sub Panel A/C Blower Range Recpt Fluorescent Fixture Pumps Transformer Appliances Dryer Recpt Emergency Fixture Time Clocks Disconnect Switches 2 Twist Lock Exit Fixtures TVSS Other Equipment: SUN ROOM, 1-paddle fan Notes: Inspector Signature: W/ J2� Date: April 30 2014 81-Cert Electrical Compliance Form.xls € a °. 'r lllD l �o��Of 30(/Ty�6 TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 PE INS TION C [� NDATION 1ST [ ] ROUGH PLBG. [ FOUNDATION 2ND ( ] INSULATION [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) REMARKS: -� DATE INSPECTOR 3 oFl # 9 TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION >1F NDA N 1ST [ ] ROUGH PLBG. ATION 2ND [ ] INSULATION MING/STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) REMARKS: IL r V-�,k s DATE 0 INSPECTOR 2 oOF iWl7Qy_ TOWN OF SOUTNOLD BUILDING DEPT. 765.1802 INSPECTION [ ] FOUNDATION 1ST [�GH PLBG. [ ] FOUNDATION 2ND [ INSULATION [ ] FRAMING/STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) REMARKS: � Y DATE � � INSPECTOR At�l L f4f so co%_ TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION FOUNDATION IST ] ROUGH PLUMBING FOUNDATION 2ND INSULATION FRAMING / STRAPPING FINAL FIREPLACE & CHIMNEY FIRE SAFETY INSPECTION FIRE RESISTANT CONSTRUCTION FIRE RESISTANT PENETRATION ELECTRICAL (ROUGH) Pol ELECTRICAL (FINAL) CODE VIOLATION CAULKING REMARKS: DAT — INSPECTO IS60 TOWN OF SOUTFIOLD BUILDING DEPT. 765.1802 INSPECTION [ ] FOUNDATION i5T [ ] ROU PLUMBING [ ] FOUNDATION 2ND [ ] 1 ULATION [ ] FRAMING/STRAPPING [ FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION C 1 FIRE nESisrart cowsrnucnoN [ ] FIRE rtESis'rAwr venernunoH [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ J CAULKING REMARKS: DATE � � INSPECTOR MIT Mir MAO PLUMING INSMATION PER N.Y. STATE ENERGY CODE ADDITIONAL COMTYMNTS 1 --- ------ -- 1 � � t ` ------ - v I ` TOW.',';OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD, NY 11971 4 sets of Building Plans TEL: (631) 765-1802 Planning Board approval FAX: (631) 765-9502 Survey SoutholdTown.NorthFork.net PERMIT NO. 3 O 7 Check Septic Form N.Y.S.D.E.C. Trustees Flood Permit Examined (o ,20 71 Storm-Water Assessment Form Contact: Approved 116 20 Mail to: Disapproved a/c f)0)& M�6�i4,IhtJ Phone: (o'3( Expiration 7 � 20_/ _ Building Inspector 1 , CATION FOR BUILDING PERMIT LThii'sapplid-!LftYU.�V''C 17 2013 Date 1 - - (a- 201INSTRUCTIONS a y filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans, accurate plot plan to scale. Fee according to schedule. b. Plot plan showing location of lot and of buildings on premises, relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application, the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize, in writing,the extension of the permit for an addition six months. Thereafter,a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York, and other applicable Laws,Ordinances or Regulations, for the construction of buildings,additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances,building code, housing code,and re ulations,and to admit authorized inspectors on premises and in building for necessary inspections. (Signature of app scant or name,if a corporation) Q-0- B--EX &aZ C vjm_uko(. i ye 1-4-k"(Mailing address of applicant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder Name of owner of premises S'V\g nCC,yc .PINT'T' ltNl T V- E tN (As on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer (Name and title`O&Mrpol awofficer), Builders License L y 'p=4 Plumbers License No. Electricians License No. Qz:-5t,k%(-- aot ee c Other Trade's License No. 1. Location of land on which proposed work will be done: 05 S b VMfiSoT P R14 e L JTn M'r'�UU House Number Street Hamlet County Tax Map No. 1000 Section ak ' Lot ZZ Subdivision rl il-d Map No. Lot 1.. 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy !91Kl- r-A-MtW Qt,3Ib61-r'z b. Intended use and occupancy Swya / 3. Nature of work(check which applicable): New Building _Addition ✓ Alteration Repair Removal Demolition Other Work (Description) 4. Estimated Cost 3 5-t.'ODp Fee (To be paid on filing this application) 5. If dwelling, number of dwelling units 3 Number of dwelling units on each floor If garage, number of cars Z. 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of existing structures, if any: Front Rear Depth Height Number of Stories Dimensions of same structure with alterations or additions: Front Rear Depth Height Number of Stories 8. Dimensions of entire new construction: Front Rear Depth Height Number of Stories 9. Size of lot: Front Rear Depth 10. Date of Purchase Name of Former Owner 11. Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law, ordinance or regulation? YES NO t/ 13. Will lot be re-graded? YES NO_/ Will excess fill be removed from premises? YES NO'S 14. Names of Owner of premises o cc tl-he ooh Address \a.!� OeA'I' (fk Phone No. 04 Name of Architect M\4a' OrANp Address Phone No Name of Contractor l DO 1` "k4fN Address P A P—Qya Go?- Phone No. 631 Lt^1.(jp4'u6 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO ✓ * IF YES, SOUTHOLD TOWN TRUSTEES & D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey, to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. 18. Are there any covenants and restrictions with respect to this property? * YES NO * IF YES, PROVIDE A COPY. STATE OF NEW YORK) SS: COUNTY OF SfguU- - D��GIakS 0k�A*AtN being duly sworn, deposes and s s that(s)he is the applicant (Name of individual signing contract)above named, Z'frt Nm* 0 Au�o f (S)He is the C_ (, G (Contractor,Agent,Corporate Officer, etc.) Vol ONf18'a 3wNo of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be performed in the manner set forth in the application filed therewith. Sworn to before me t 's day of 4 20 Notary Public �ry Pte' dj Ng.Y e scant No.ID18MINM 0U&M11n suA*0W* CwrMs�lon E q*n App Scott A. Russell �°SOFFQ '� James A. Richter, R.A. SUPERVISOR Michael M. Collins, P.E. SOUTHOLD TOWN HALL-P.O.Box 1179 SM Main R n 17 Telephone#: (631)-765-1560 ( - 5 MICHAE LCOLLINSOMWN.SOUTHOLD.NY.US � 1AMEM WN.SOUTHOLD.NY. Office of the Engineer DEC 24 Town of Southold BLDG. DEPT. TOWN OF SOUTHOLD STORMWATER MANAGEMENT CONTROL PLAN REVIEW COVER SHEET (TO BE COMPLETED BY THE APPLICANT) TO: ENGINEERING DEPARTMENT PLEASE ATTAal THE FOL101I1W BoaleffS*or 1WRX4TIoN. FROM BUILDING DEPARTMENT ❑ Copy of completed Application for Building Permit DATE: ❑ Stormwater Management Control Plan APPLICANT. 0XV, ❑ Completed Chapter 236 Stormwater S.C.T.M. Review Checidist PROPERTY ADDRESS: BRIEF PROJECT DESCRIPTION i R ENG E I G EPARTMENT USE ONLY''°'* Reviewed By U Date: z 7 l3 I APPro ed: I ❑ Additi Information Required A 1 aufr DATE: CHAPTtR 236 APPLICANT: Storm�water Re iew Checklist s.c.T.r�t.#: _ PHYSICAL ADDRESS: Stormwater Management Contr6I Plan Requirements* Yes No NA If No or NA,Please Provide Additional Information 1. Plan drawn to scale of not less than 60 feet to the inch sh wing: a. location and deseriptton of property.bouadaries b. total site acreage c. existing and natural and mati-made features on and within 500 feet of the site boun as n*uired in 23647 2 . 1/ d. test hole data indicating soil characteristics and the depth to water e, proposed limits of clearing and the total area of propo ed land disturbance £ existing and proposed contouts of the site(minitnuiri 2' interval) g. location of all existing and proposed structures,roads,(driveways, sidewalks drain vements'and utilities h, spot grade and finished floor elevations for existing and proposed structures i. location of the swimming pool discharge ring j. location of proposed soil stockpile area(s) k. location of the proposed ConstWtion entrance/staging areas 1. location of the proposed,concreee washout area f m. location of all proposed erosion and sediment control measures J 2. Plan includes calculations showing that the stormwater improvements are sized to capture,store and infiltrate on-site the runoff from all ✓ impervious surfaces enerated b a two raifanll 3• Detail drawings(ragMiaLfor tan anR provided for: a. erosion and sediment controls ✓ b. construction entrance V c. inlet-structures(e-& catch basins,trench drains,etc.) d. leaching structures(e.g.won basins,swalM etc.) REVISED 7/24/2013 islift ING WARWFNT TOW"OF lj+tyvru4 z Nmw �oa�� e�Q� FAR,�L�,�TF3�CAL �NS��►� a�s��EC►ear: °�'� 3�y/�y ►�ndicates naquined ir AIM: lon) jC"fTE oRWTKM: CI `Nsine: Q GG !w 7-/ •Addmn: Pail •Phr*No.. Z 7 P411114 No.: o Tam Wimp MOW ._... Section: q Block - -,7 Lot: -BMEF DESCRpTfoN OF WORK (131"" P"C.bw*) �. .� Cbvb M TW APPIV) •t„pb as"ftr fit: YES wo F� Yb you now 0 TWW Cadwasw: YES CjDD TN�p MMiorn��on_�M��! '9NVkas slow. 1 PhM 3P1aw 100 150 200 304 300_ 4W der__. 'Iwwv=Swwlc�r:- M r�orM' Uerd grnund NumbwofWkft Oho of 8mv" Owrtwrwc! A�ltlM�orari�ren�dlba�rr �`�'� �.���► �'�-� �� ,, IK L TME INSURANCE YORK �n 0 C) �3' 1419 TO I L 9 - �� rn -24A +� tt , Cl R� i 1 1 lot 3 I S 1004511011 E 102 -9601 S 13009 '40 " E 57.130 1 SITE DATA: DESCRIPTION: SQ.R AREA: LOT COVERAGE: EXCAVATE: fILL: I M U H PROPERTY: 20222.7 SQ.FT. 0.46 ACRES I Design Services ESTIMATED AREA OF 700 SQ.FT. GROUND DISNRBANCE: +/- I Iwww.mchdesianservices.com EXISTING HOUSE: 1170.2 SQ.FT. 5.8% phone: EXISTING PORCH/DECK: 136.0 SQ.R. 0.7% (631) .7% (631)298-2250 O I e-mail: EXISTING GARAGE: 480.0 SQ.FT. 2.4% 1 michael @mchdesignservices.com o I 20.0 PROPOSED ADDITION: 312.0 SQ.FT. 1.5% 54 CU.YD. 42 CU.YD. W \10 I EXISTING o _ I GARAGE N PROPOSED DRYWELLS: 3CU.YD. 1 N.YD. — � I O m TOTAL 2098.2 SQ.1[ 10.4% 57 CU.YD. 44 CU.YD. I O rn 18.01/ I 0 W N SEQUENCE OF PROJECT: o Ln U—i V 1 SITE CLEARING:CLEARANCE OF MINIMUM SITE WORK AS NEEDED.INSTALL BERMS,HAYBALES,SILT FENCING AS REQUIRED.RUNOFF I PROTECTION TO BE MAINTAINED DURING LENGTH OF CONSTRUCTION.EXCAVATION MUST NOT BEGIN UNTIL THE LOCATIONS I �"s z OF UNDERGROUND WIRES,CABLES AND PIPES HAVE BEEN MARKED OR UNTIL VERIFICATION FROM UTILITY COMPANIES THAT THE Q 49.7C 0 UJI AREA IS(LEAR. CLEAR THE SITE AT LEAST 20.25 FEET(If APPLICABLE)FROM THE PROJECT PERIMETER.DO NOT CLEAR OR EXCAVATE 143 LARGE AREAS TO FAR IN ADVANCE OF CONSTRUCTION;DISTURB VEGETATION ONLY AS NEEDED,THEN RESEED OR REPLANT AS SOON AS — — — — — PRACTICAL.LIMIT EQUIPMENT TRAFFIC IN AND OUT OF THE JOB SITE.DO NOT DRIVE OVER UNCLEARED AREAS.PROTECT UNCLEARED AREAS WIN SYSTEM.IF A PEEBMANfNI DRIVE CAN NOT BELINSTALLLLEDI BEFORE CONSTRUCTION BEGINS, 10 PREVENT GRAVEL DRIVEWAY SHOULD BE O INSTALLED WHERE VEHICLES ENTER THE JOB$ITE. _ EXISlTNG N 2 POLLUTION CONTROL CONSTRUCTION DUMPSTER AND PORTAIAV TO BE ON SITE AND MAINTAINED DURING LENGTH Of PRO)ECT. cr\ 1 STY Lf) � 2 STY. FRMD. HSE. ry) 0 04 0 O 3 SOIL CONTROL:EXCAVATED SOIL TO BE RETAINED ON SITE AS INDICATED ON SITE PLAN.RETAIN AS MUCH TOP SOIL AS POSSIBLE TO N N AD D ITT O N CONSTRUCTION DUM PSTE PRESERVE THE ENVIROMENTAL QUALITY OF THE PROJECT SITE.EXCESS FILL TO BE SHIPPED Off SITE.CONTRACTOR AND EXCAVATOR TO REMAIN ON SITE FOR w Q SHALL INSPECT PROPERTY FOR EXISTING UTILITIES B90RE EXCAVATION BEGINS.ANY DIGGING WITHIN 24 INES OF UTILITY MUST BE DONE BY HAND.WHEN THE TOP SOIL IS PRESERVED,TILL THE SOIL FIRST,AND THEN REMOVE TO A SAFE LOCATION WITH A FRONT DURATION OF CONSTRUCTION O Q r A x END LOADER,PROTECT GRASS,(BEES AND OTHER PLANTS WHENEVER POSSIBLE 0 EXCAVATION SHOULD BE AS LEVEL AS POSSIBLE.SET ELEVATION BENCH MARK PRIOR TO EXCAVATION.OVER DIG n FOUNDATION HOLES TO GIVE PLENTY OF ROOM FOR A WELL-DRAINING BACK FILL AND TO PROVIDE ROOM FOR ALL WORK. 16.0' Z Ln �J A).If THE DEPTH Of EXCAVATION IS 6 FEET OR LESS,OVER DIG BY 3.4 FEET. ON B).If THE EXCAVATION U DEEPER THAN 7 FEET,THE SIDES MUST BE SLOPED OUTWARDS AT A 45 DEGREE ANGLE ABOVE 4 FEET OR 0.3 NOTED INSTALL SHORING. 7777777 HILLSIDE EXCAVATION:EXCAVATE THE HILL BACK 10 AN ANGLE OF REPOSE-THE ANGLE AT WHICH THE SLOPE IS STABLE,USSUALLY ( �� ��"' a V z - BACK TO A SLOPE 9 2:1 VERIFY SOIL CONDITIONS). 4.0' EXISTING, A).AN UNSHORED VIRTUE CUT SHOULD NOT EXCEED 5 FEET ON A SLOPED SITE. Q O i � � I �`T E�B.P. #3�Z.-._ . 14.0' PORCH V ! ' ( 4 STORM WATER RUNOFF CONTROL:INSTALL DRYWELLS(AND SEPTIC IF NEEDED)DURING CONSTRUCTION.GUTTERS AND DOWN SPOUTS L! 0' STORM WATER NRYWELL TO BE IAAEDIATLY INSTALLED AT TIME OF COMPLETION OF ROOF.ALL DOWNSPOUTS 10 BE PIPED TO DRYWELLS AT THIS TIME. I I REQ�� ak i rS° PORT-A-LAVE TO REMAIN VE�I�^gym BY _ UNDERGROUND HOOKUPS(ELECTRIC,WATER,GAS,9010 BE INSTALLED. ' '�°°'�` 10°°"'� rori E \ / ON SITE FOR DURATION Tl Y B U I L D I P 1 G D E PA{;1)E i) V I OF CONSTRUCTION 765-1802 8 Al l TO 4 P l 9 For"', T 5 PROJECT COMPLETION:FINAL GRADE 10 CONTROL RUNOFF DIRECTION TO STAY WITHIN SITE.PITCH GRADE ALONG PERIMETER FOLLOWING INS P E C T I O N S (WHERE POSSIBLE)OF LAND DISTURBANCE AWAY fRDM NEIGHBORING PROPERTIES AND ROADWAYS.INSTALL CATCH BASINS WITH 1. FOUNDATION -TWO REQUIRED DRYWLS AS REQUIRED FO CONTROL RUNOFF HAT CANNOT STAY WITHIN DISTURBED AREA. FOR PO U RE D O CONCRE's E O2. ROUGH-FRAMING, PLUMBING, ' ELECTRICAL CAULK!P.I ASPHALT 3 INSULATION O4. FINAL-CONSTRUCTION & ELECTrRICf I q DRIVEWAY MUST BE COMFLETE FOR C O. ALL.�CONSTRUGTfO.N� t idlf-i_W17 THE n� REQOIRE�MENTS OF`T iE "Or"'S CIO ; 1. YORK STATE. NOT RESPCNl`IIB?E FOi? � I . :-D�Bi60Rt6iS'f °TfOiq ERRORS. r' DRAWN BY: MH I RETAIN STORM WATER RUNG 12/15/2013 I PURSUANT TO CHAPTER 236 I OF THE TOWN CODE. SCALE: 1/4" = 1'-0" N 13009 '4011 W 160.000 ��"'j SHEET NO: -�r,5 w Q5 1, SITE PLAN E S� DIT E11) A7f?Dfl _ _ ' d d Q SCALE: 1" - 10'-0' � d ELECTAICAL as.�'"��'s.� �,-�� a ��,-:�<�,t �rz�•1 a;�G,^� k, A M H Design Services – —_ – – — – www.mchdesianservices.com phone: (631)298-2250 e-mail: michael @mchdesignservices.com nil III . . z LLL LFT Ow p A FRONT ELEVATION wow SCALE: 1/4" = V-0" L HAx W Z - ___ - - - _- QU � o Elm a DRAWN BY: MH 12/15/2013 FILI SCALE: 1/4" = V-0" NEW YO SHEET NO: ElDEfR w FOA ° 072b '40FE 10N` O RIGHT ELEVATION SCALE: 1/4" = V-0" M C H Design Services www.mchdesignservices.com phone: FM (631)298-2250 e-mail: michael @mchdesignservices.com z U I 1 11 1 1 1 1 1 -1 L I I I LL.L I H I 1!:� 1 1 .11 .1 1 . 1. 11 11 1 1 1 L� A wow REAR ELEVATION 141 f oil r� SCALE: 1/4" = 1t-011 E-N4 W i t 1 I W z A U 0­4 Ln EXISTING 5/4" DECKING ON 1-NINNIN11 V rl Generated by RESchecik-Web Software O . 2X ACQ SLEEPERS Compliance Ceftiflcate EPDM,FLASHED ON x _ 3/4" EXT.T&G SHTG. RAILING — _ _ — r , ax�� xrx� P o Q U �� ,� I I r � 1� ��,,;�,,�,•o.s.�, � ( �� - � roject ( ( � yr nrn wssm sir�mwc Iq f I r I ` I I 'I ` I 11 I I I ((( Er�u ry ,PS•osa.7 F„agy code: 2910 mew Yolk EneW Conse wation (h I/ I Suffolk County New York O �. :�o=<xxx�=r� ( ! I S I( ( I 1 cor,su.Ke4nType: Sir}gle-famky — - - — — I I ( i I I 1 � � cranraezone: A (5750 HDD) 1-3/4X9-1/2 ML C&12"OC - , PemR oao� PemdtNumher Construction Site: OwnedAgent: DesignedContractor - z. S1 MtPn 195 35 Mr PATH I ,...d..da.o .u.:Yr..w MU.A.:�s eaWNan :arik setits ihar code w«imum UA: Ma . w.iMrrvL.. EXISTING rn I L I I ( � ( ' /( �( 2X4 STUD WALL (I I ( (I ( ( ( Envelope A ssernblies O BARRIER,/2"SHTG DRAWN BY: MH SIDING VAPOR TO MATCH ! i ITI , ,„•„„a„xo� Flo«:+a11-wood iOisvrn,$Over Unooa&spree 216 30.0 o.o o= Wok wood Frame.16in-ox- 414 23-0 CA 8.0112 17 12/15/2013 We.dwr wood Frame.2 Pare wl'Loo-E 200 0.390 50 — ti 2X10 DF#2 FJ @12"OC 1 Ceiing:FlatorSdssorTruss 21G 21A 0A 0.047 10 ® _ _ _ _ _ SCALE: 1/4" = 1'-0" f I I tbw{orirrAx Stoop rent•The buv;aJding design described hem is CWPANtwnt wid.fire built plsm,spe cations,and oth ( crlcdations sulsmitted ssids tl�e permit appli�atian.TFm prapaoed Iws'Idinq Isar be designed is meet the 2010 New York E—g�y . Conswetiors Construction{'.ode requirements in RE5d eck Version 5.5.o ord to comply with the mendeb:wy requiremene I-r:ted in snros ( f I ( the RESrhm*Inspection Ched�st +• •• ( I ( ( \ I l�I I lI ( ►, 0. S" PC WALL - .% DAMPPROOF o SHEET NO: 2" CONC.SLAB I I d: a EXISTING 16°X8° CONC.FTG. 1-]%4xFY]SNbSNMNKI® (Z)#4 REBAR C, DEERf 'Q u+o xurs r ro•nc • O .�. WIND-BORNE DEBRIS PROTECTION FOR WOOD STRUCTURAL PANEL r � AS PER TABLE 1609.1.4,N.Y.S.RES.CODE:ALTERNATIVE FOR OPENING PROTECTION(IF NOT USING IMPACT GLAZING) •. 2 W LIJ WINDBORNE DEBRIS PROTECTION FASTENING SCHEDULE FOR WOOD STRUCTURAL PANELS WOOD STRUCTURAL PANELS WITH A MINIMUM THICKNESS OF 7/16' d, AND MAXIMUM PANEL SPAN OF 8 FEET SHALL BE PERMITTED FOR OPENING PROTECTION IN ONE-AND TWO-STORY BUILDINGS.PANELS SHALL BE PRECUT TO O• Q G� •• ` COVER GLAZED OPENINGS WITH ATTACHMENT HARDWARE PROVIDED.(REFER TO SECTON 1609.1.4,1609.6.5 AND TABLE 1619.1.4 OF N.Y.S.RESIDENTIAL • CROSS SECTION � CONSTRUCTION CODE).THIS IS NOT A SUBSTITUTION FOR DESIGN-PRESSURE.ALL OPENINGS MUST HAVE DESIGN-PRESSURE UPGRADES WHERE APPLICABLE ALL PANELS MUST BE CUT TO SIZE AND READY TO USE ON ANY NEW WINDOWS AND DOORS,SHUTTERS MUST BE MARKED FOR WHAT OPENING IT IS TO COVER. HARDWARE MUST ACCOMPANY SHUTTERS FOR INSTALLATION. Pro0a Tom_ iRepolt date: :WI.SM R�FESS��NP Datafdename- Page'lof 7 SCALE: 1/4" = V-Olt 1\ M C H Design Services www.mchdesia nservices.com phone: (631)298-2250 e-mail: michael @mchdesignservices.com I 1 1 1 1 1 1 1 44 REBAR @ 12"OC &AT FTG. (TYP.) _ _ __ _ w ............d 1=augdataaa�/ant=--------------Q-----� I D o o a p a , 0 1 -------------------------------------------- I 1 I C I I I ` I II U1 I 1 I z I I I I 1 v I a 1 1 I 1 p 1 1 � I I I I P I 1 I z Z I 1 W I 1 0 O W EXISTING N Ln 2X10 DF#2 F @12"OC o� O V ' I Q 1 p I I I Lu N 1 I U x LLJ Z ^ 1 D 1 I 1 I 1 u I I U I I O I � I 1 v I I I U I � I 1 I -------------------------------------------- 1 I I #4 REBAR @ 12"OC -------------------o"Ada4a _wm-------------------- O &AT FTG.(TYP.) w 16'-O" IVA 1).8"'THICK POURED CONCRETE FOUNDATION.VERIFY HEIGHT ABOVE GRADE AND ADJUST AS REQUIRED FOR FINISHED FLOOR TO MATCH EXISTING. EXTERIOR OF FOUNDATIONS TO BE DAMPPROOFED WITH A BITUMINOUS COATING. 2).FOUNDATION TO HAVE 16"X8"CONCRETE (2X4) KEYWAY FOOTING.FOOTINGS TO HAVE 2-#4 CONTINUOUS RE-BAR.ALL FOOTINGS TO REST ON DRAWN BY: MH UNDISTURBED SOIL (MINIMUM 3000#CAPACITY). 1 1 3).FOUNDATION SLAB TO BE 2"THICK. 12/1S/2013 I I ' 4). PROVIDE 2X6 ACQSILL PLATE.SILL PLATE TO BE INSTALLED OVER 1 CLOP-R-TEX TERMITE SHIELD AND SILL GASKET SCALE: 1/4" = V-0" --------------------------- 5).PROVIDE 5/8" DIA ANCHOR BOLTS AT 6'-0"O.C.AND W/I 1'-O"OF CORNERS, INTERSECTIONS AND SPLICED JOINTS.ANCHOR BOLTS ARE TO HAVE A MINIMUM 7" IMBEDMENT INTO THE CONCRETE.EACH ANCHOR BOLTARE TO FOUNDATION PLAN BE ATTACHED TO SILL PLATES WITH 3X3 SQUARE WASHER AND NUT F NEW SHEET N O SCALE: 1/4" = V-0" SPA DEeR'�y°'p'f- 2 ZN�OA 0- 7�� �- A 0 Q3 I M C H Design Services www.mchdesionservices.com phone: (631)298-2250 e-mail: michael @mchdesignservices.com 16'-0" T-10% 81-1%" ' DBL.2k4 POST(TYP.) CW155 CW155 CW155 CW155 CW155 O (2) 2X10 DF#2 HEADER r , zL , W u _ Lr) Ax LL ° N J ~ 0 0 v u, D O P4 to � u O EXISTING 1-3/4X9-1/2 ML @12"OC 00 Q � A V � w w �_ W cn a N LL § O p 0 V N_ � Q X N V N n lug O (2) 2X10 DF#2 HEADER O -- CLOSE OFF CW155 CW155 CW155 CW155 CW155 EX.OPENING DBL.2X4 POST(TYP.) 161-011 1).PLATE HEIGHT AT 9'-0" UNLESS OTHERWISE NOTED. 2).EXTERIOR WALLS TO BE FRAMED WITH 2X4 DF#2 STUDS AT 16"O.C.. DRAWN BY: MH 3).EXTERIOR SHEATHING TO BE 1/2"THICK FIR CDX PLYWOOD. 4).ALL OPENINGS TO HAVE 2 JACK STUDS ON EACH SIDE OF OPENING. 12/15/2013 PLACE WITH PLATES AND BOLTS TO STEEL BEAMS 5).ALL EXTERIOR OPENINGS TO HAVE DESIGN-PRESSURE UPGRADES WHERE APPLICABLE.PROVIDE DEBRI-PROTECTION PANELS WITH FASTENING SCALE: 1/4" = 1'-0" HARDWARE UNLESS OPENINGS HAVE IMPACT GLAZING. 6).ALL MULLS,VERTICAL OR HORIZONTAL,ARE TO BE PROVIDED WITH -- - -- ---- - ------- Z-ZX DF#2 STUD POSTS UNLESS OTHERWISE NOTED. SHEET 7). INSULATE EXTERIOR WALL WITH R13. NO: '` F NEW Y 1ST. FLOOR PLAN 8). INSULATE CEILING WITH R30 INSULATION. �'�P ��• DEfR,f0'p,� 7)r Q O�� 9).ALL WALLS AND CEILINGS TO BE PROVIDED WITH 1/2"SHEET ROCK. r- a SCALE: 1/4" = 1'-0" _... ' W W �Fp 'Lo. 0 �R�FESS1 M C H Design Services www.mchdesignservices.com phone: (631)298-2250 e-mail: michael @mchdesignservices.com Z C) U }�-- z Lu < Way P4w0 _, PROPOSED DECK I� W co pHQ EXISTING N S/4 DECKING OVER ACQ SLEEPERS,PITCHED 1/8":1'-O" U AWAY FROM BLDG,INSTALL SLEEPERS OVER EPDM Ln &3/4"AC EXTERIOR SHEATHING.EPDM TO RUN UP ON SIDE WALLS 24".PROTECT WALL INTERSECTIONS, r , SHARP INTERSECTIONS AND PERIMETERS WITH V LEAD-COATED COPER OVER EPDM. INSTALL AS PER MFGRS.INSTRUCTIONS. PROVIDE 4" PVC DRAINS TO O H CONNECTTO REMOTE DRYWELLS (TYPICAL) o � ______________________________________________: 0 DRAWN BY: MH 12/15/2013 SCALE: 1/4" = V-0" 2ND. FLOOR PLAN SCALE: 1/4" = 11-011 SHEET NO: OF NEW y 1. DEFR� Q asf. _ w 0 ' uj 4 Lu ti � � 0 Z�F'04 0 072P �A� WIND LOAD PATH CONNECTION AND CONSTRUCTION DETAIL DRAWINGS - USE THE FOLLOWING APPROVED USP METAL CONNECTORS FOR PROPER WIND RESISTANT 4 GOOD CONSTRUCTION, FOLLOW MANUFACTURES RECOMMENDED INSTALLATION INSTRUCTIONS TO ACHIEVE MAXIMUM UPLIFT LOAD CAPACITY, M C H KING STUDS \ Design Services RAFTER WALL STUD ENDWALL CRIPPLE STUD BOTTOM PLATE RIDGE LEDGER BATHTUB www.mchdesignservices.com HEADER DOUBLE JOIST phone: SIDEWALL RAFFER (631)298-2250 JACK STUDS e-mail: FLOOR USP NUMBER DESCRIPTION APPLICATION michael @mchdesignservices.com 1ST. ADS5 HOLD DOWN CONNECT TO 1 SIDE OF ALL CORNERS ANCHOR TO FOUNDATION W/ANCHOR BOLTS BATH/SPA TUBS TO HAVE A DOUBLE FLOOR JOISTS UNDER FOR ADDED SUPPORT CONNECT TO 1 SIDE OF ALL CORNERS ON LOCATION USP NUMBER DESCRIPTION APPLICATION LOCATION USP NUMBER DESCRIPTION APPLICATION RAFTER SIZE USP NUMBER DESCRIPTION APPLICATION SUPPORT EACH WALL RUNNING PARALLEL WITH THE FLOOR HOLD DOWN BOTH DOT.PLATE OF 2ND FLOOR AND TOP JOIST DIRECTION WITH(2)JOISTS.UNDER WALL. 2ND. ADS5 ANCHOR PLATES OF 1ST.FLOOR.CONNECT THROUGH ALL OPENINGS LSTA12 1-1/4"x12"20ga.STRAP APPLY TO EACH JACK STUD ROOF LSTAZ4 1-i/4"x24"20ga.STRAP APPLY OVER RIDGE TO EACH RAFTER 2x6 2x8 L526 18ga.SLOPE HANGER APPLY TO EACH RAFTER/LEDGER FOR JOIST NOT DIRECTLY UNDER PARALLEL WALLS,PROVIDE THE FLOORS TO EACH OTHER W/THREADED ROD. ALL OPENINGS R73 OR RT7 TYDOWN ANCHOR APPLY TO EACH CRIPPLE STUD 2X10 LS210 18ga.SLOPE HANGER APPLY TO EACH RAFTER/LEDGER BLOCKING @24"OC WALL STUD THROUGH-ROOF EXHAUST VENTS SELECTED AND LOCATED BY CONTRACTOR METAL STRAP CRICKET AT TOP-SIDE OF VENTILATION CHANNEL RIM BOARD CHIMNEY RAFTER AS REQUIRED SILL PLATE(S) /WALL SHEATHING RAFTERSN7iL�gTION WOOD JOIST BLOCIGNG • ' ' SIDEWALL FLASHING BLD FOUNDATION - 2x4 LEDGER TOP PLATE BLOCKING FINISH WALL AND MOISTURE W $TAPPING TO DE ATTACHED TO WALL STUDS @48"OC BARRIER TO LAP FLASHING ' 2x4 SOFFIT JOIST O AT WALL-MAINTAIN GAP ATTIC SHALL BE PROVIDED WITH A FASCIA r 1 AND ALL WINDOW/DOOR OPENING JACK STUDS MINIMUM NET FREE VENTILATING AREA - - ►V/ BETWEEN WALL FINISH AND FLOOR JOIST DEPTH USP NUMBER DESCRIPTION APPLICATION WALL STUD NOT LESS THAN 1/150 OF THE AREA OF GUTTER WOOD GIRDER ROOFING TO AVOID SOAKING THE SPACE VENTILATED. ALL OPENINGS INSTALL 4'0"O.C. �,'� ONTIN.SCREENED VENT SHALL BE COVERED WITH CORROSION 4"-8" LSTA24 1-1/4"x24"20ga.STRAP AND JACK STUDS , CONTIN.SOFFIT/EXT.PLYWOOD ON ALL OPENINGS PROVIDE HEMMED EDGE AT RESISTANT METAL MESH WITH MESH INSTALL 4'0"O.C. '�' FLASHING TO FORM CHANNEL LOCATION USP NUMBER DESCRIPTION APPLICATION OPENINGS OF 1/4 INCH IN DIMENSION. SOFFITED SAVE 8"-14" LSTA30 1-1/4"x30"18ga.STRAP AND JACK STUDS / ,` �� AND SO AS TO MAINTAIN AIR EEACHRAFTER TO —� ON ALL OPENINGS ' GAP TO PREVENT CAPILLARY 4"-6"RAFTER RT1D 10-3/4"x 18ga.TYDOWN ANCHOR PROVIDE BLOCKING BETWEEN JOISTS THAT ARE SPICED AND `" ACTION ROOF VENTILATION OVER BEARING WALLS AND HEADERS IINSTALL 4'0"O.C. TO 14"-16" LSTA36 1-1/4'x36"18ga.STRAP AND JACK STUDS 8" 12"RAFTER RT20 21-118"x 20ga.TYDOWN ANCHOR TER SOFFITED EAVE DETAIL �..�� (~L•1 ON ALL OPENINGS KEEP ROOFING NAILS OUT OF FLASHING Q ^ 2ND.FLOOR `\ ROOFING LAPS BASE FLASHING 4 INCHES BASE FLASHING WRAPS CORNERS, RAFTER RIDGE CAP OF SAME \/ EXTENDS UNDER SHINGLES AT I MATERIAL AS ROOFING NAILED TO SHEATHING O SIDES 4 INCHES AND LAPS THROUGH VENT SHINGLES AT BASE MIN.4 INCHES WOOD JOIST Q � A WALL d J� �I TOP PLATE GIRDERIHEADER Z In V� SIDE WALL FLASHING WOOD JOIST � (�1 1ST.FLOOR WALL $TAPPING TO BE ATTACHED TO WALL STUDS @48"OC V AND ALL WINDOW/DOOR OPENING JACK STUDS METAL FLASHING AT ALL EAVES,SIDEWALL$, WALL STUD FLOOR]GIST DEPTH USP NUMBER DESCRIPTION APPLICATION AND RAKES-PROVIDE HEMMED EDGES SO RAFTERS INSTALL 4'0"O.C. AS TO FORM DRAINAGE CHANNELS AND H PREVENT CAPILLARY ACTION LOCATION USP NUMBER DESCRIPTION APPLICATION PRE-MANUFACTURED 4"-B" LSTA36 1-1/4"x36"18ga.STRAP AND JACK STUDS KEEP SHEATHING MIN.1-1/2" ALL JOISTS CONNECTED TO A FLUSH HEADER TO BE SUPPORTED WITH ON ALL OPENINGS CONNECT EACH RIDGE VENT FOLDS FROM PEAK TO ALLOW FREE THE PROPER STEEL CONNECTOR. [PLATE R/PLATE RT15 TYDOWN ANCHOR RAFTER TO PLATE OVER RIDGE TO AIR PASSAGE IF ABLE,SET FIR JOISTS APROX.1/2"HIGHER THAN LVL HEADERS INSTALL 4'0"O.C. CONFORM TO SLOPE 8"-16" MSTA48 1-1/4"x48"16ga.STRAP AND JACK STUDS /WALL SPTH4 STUD PLATE ANCHOR CONNECT OVER OF ROOF TO ALLOW FOR SHRINKAGE.&REDUCE BUMP OUTS ON ALL OPENINGS PLATES TO EACH STUD DEL.SILL PLATE SUBFLOOR I O TERMITE SHIELD SILL GASKET I WOOD JOISTS i r 0 NEOPRENE ' CONC.SLAB GASKET ' 2x6/2x8 CONTINUOUS WOOD PLATE TYP.CONC.FOUNDATION C A 6 MIL.POLY Vx '� � i r BOLTED TO STEEL BEAM WITH DAMPPROOF EXTERIOR y GRANULAR FILL r • - ` i I 1/2" DIA. BOLTS*48"o.c. STAG. CIO 6MIL POLY ON EXTERIOR • V i STEEL COLUMN p A > q • q P C e \ ( ROOF JACK STEEL BEAM V CONC.SLAB ' p - • // i u e C 1% I ,A I COMPACT FILL A n� r ROOFING LAPS `. TOP A AND BOTTOM PLATE A e p ^ FLASHING AT , WITH 1/2" x 6" ANCHOR BOLT KEYWAY FOOTING a V �•p CONC.FIG. p ,q Q`p 1 G> USE WITH 3x3 SQUARE WASHERS SIDES AND TOP `� 1/2"GROUT e•e .1 ^ ,G ANCHOR BOLT CONNECTION (USP LBPS58 OR BP583) � ^ - I I I �-- — 3" STEEL COLUMN D � REINFORCING BAR FOUNDATION 5/8"DIA.ANCHOR BOLT DRAIN TILE p ANCHOR BOLT CONNECTION SUPPORTING MAXIMUM SPACING FLASHING LAPS �� � � ( lo KIPS SILL PLATE TO FOUNDATION ROOFING AT BOTTOM CRAWL SPACE OR FOUNDATION STORY 72"OC SILL PLATE TO FOUNDATION TYPICAL BEAM DETAIL TYPICAL CONC.FOUNDATION.APPLY PILASTERS MIN.3"STEEL COLUMN ANCHORED TO 24"x24"Al2"CONC.FTG. CRAWL SPACE OR FOUNDATI N 2 STORIES 36"OC STEEL / BOTTOM BEARING DRAWN BY. M H WHERE NEEDED FOR STRUCTURAL BRACING. WALL BOTTOM PLATE TO FOUNDATION t_2 STORIES 57"OC (SLAB-ON-GRADE) JACKS 4 VENTS DETAIL SUBFLOOR 12/15/2013 CONC.SLAB GARAGE I DOOR FRAME 6X6 10/10 WWM G--JOIST COMPACT FILL i DOOR I USE 2X8 SCALE: 1/4" - 1 -0" I FOR BLOCKOUT STEEL BEAM 4" SLAB I SLOPE P.T.PLATE W/6X6 WMM 4"DRIVEWAY NOTCH JOIST AND ADJUST HEIGHT 5PACE 1/2"AIR < I ° (WITH A NAILING PLATE IF NEEDED) Y , AT END AND e' •" �p • °• ••'• ► TO BE BEAM TO 1/2"OR HIGHE N SHEET NO: ALLOV� GRADE • q -�-st --^ -u-- -� • q •. q .` C e G•Gtp BEAMS F WOOD .e 4 �•e • • (PROVIDE STRAP ING TO EEP JOH ALIT ) p I I p Q 6X6 W.W.M. ,- - -�,- - -' - - ', e =� I o ° NEW 12" R r MIN. e�%p -e °G 'r q Q'p q L\'p q n'r • `„NOTCH BEAM FOR MUDSILL IF REQUIRED--MAXIMUM i p D •>C • e „''e q REINFORCING BAR _ NOTCH EQUALS 1/4 DEPTH OF BEAM a Q•,e•>•�e EE Q .O a REINFORCING BAR a. •' q�), C•°�•e s� DRAIN TILE 1!—n % : SHEET METAL/30#FELT UNDER BEAM AT POINT 12" •- ' OF CONTACT WITH CONCRETE OR CONC.BLOCK r- E - W 3 LAT TYPICAL CONC.MONOLITHIC FOUNDATION.REINFORCE WITH(2)#4 REINFORCING BARS THICKEN SLABS BENEATH BEARING WALLS AND COLUMNS. n a A SHIMS TO LEVEL BEAM fi EAM) z REINFORCE FOOTING WITH(2)#4 REINFORCING BARS. 3"MINIMUM BEARING SURFACE FOR WOOD BEAM GARAGE DOOR BLOCKOUT 2J, 0. 7 Q BEAM POCKET ��j0 2 P� C3 O I GEERAN L NO�' Gam' WIND FRAMING NOTES NAILING SCHEDULE PLAN CONTENTS: 1).RIDGE-TO-RAFTER ASSEMBLY: ROOF FRAMING: OCCUPANCY CLASSIFICATION R3 RESIDENTIAL M 1-1/4"x 20 gauge strap shall be attached to each pair of rafters in accordance to table 3.4. NAIL NAIL RESIDENTIAL DWELLING When a collar tie is used in leu of a ridge strap,the number of 10d common nails required JOINT DESCRIPTION QTY SPACING NOTES BUILDING USE CONSTRUCTION NOTES: in each end of the collar tie need not exceed the tabulated number of 8d nails in the strap. RAFTER TO 8'WALL:3-8d COMMON EACH UILDING HEIGHT 26'-2 1/z" TOE-NAIL FT. CEILING JOIST 8'WALL:3-8d COMMON EACH Design Services TOP PLATE 10'WALL:4-8d COMMON RAFTER TOTAL 1).The information within this set of construction documents is related to basic design 2).RAFTER-TO-WALL ASSEMBLY: SQ. FT, OF CONSTRUCTION 1ST.FLOOR: 1175 SQ.FT.,2ND.FLOOR:943 SQ,COVERED PORCH: 136 SQ.FT.,STOOP: 19.5 SQ.FT. intent and framing details.They are intended as a construction aid,not a substitute Lateral framing and shear wall connections for rafter,ceiling or truss to top plate shall be in TO TOP PLATE 10'WALL:4-8d COMMON JOIST TOE-NAIL for generally accepted good building practice and compliance with current New York accordance to table 3.3.When a rafter or truss do not fall in line with studs below,rafters PRESCRIPTIVE AS PER N.Y.S. RESIDENTIAL CONSTRUCTION CODE AND State building codes.The General Contractor is responsible for providing standard or trusses shall be attached to the wall top plate and the wall top plate shall be attached to CEILING JOIST TO AS PER TABLE 3.7 EACH FACE DESIGN CRITERIA ISS5 SBC HIGH WIND EDITION WOOD FRAME CONSTRUCTION MANUAL construction details and procedures to ensure a professionally finished,structurally the to the wall stud with uplift connections.Roofs overhanging the rake side of the building PARALLEL RAFTER WFCM-SBC LAP NAIL sound and a weatherproof completed product. shall be connected with uplift connections in accordance with table 3.3c. CEILING JOIST LAPS AS PER TABLE 3.7 EACH FACE FRAMING ELEMENTS AS PER FLOOR PLANS CROSS SECTION AND GENERAL NOTES www.mchdesiQnservices.com OVER PARTITION WFCM-SBC LAP NAIL EXT. BALCONIES 60 phone: 2).The General Contractor is responsible for ensuring that all work and construction 3).WALL-TO-WALL ASSEMBLY: COLLAR TIE AS PER TABLE 3.4 EACH FACE DECKS 40 (631)298-2250 meets current federal,state,county and local codes,ordinances and regulations,etc. Wall studs above and studs below a floor level shall be attached with uplift connections in TO RAFTER WFCM-SBC END NAIL ATTICS w/o STORAGE 10 These codes are to be considered as part of the specifications for this building and accordance with table 3.3b.When wall studs above do not fall in line with studs below,the studs shall be attached to a common member in the floor assembly with uplift connectors in BLOCKING EACH TOE ATTICS w/ STORAGE 20 e-mail: should be adhered to even if in variance with the plan. Y P TO RAFTER 2-8d COMMON END NAIL DESIGN LOAD CALCULATIONS michael @mchdesignservices.COm accordance with table 3.3. ROOF (GROUND SNOW LOAD) 45 3).Dimensions shall take precedent over scaled drawings. RIM BOARD EACH END (LIVE LOADS PSF) ROOMS (OTHER THAN SLEEPING) 40 TO RAFTER (DO NOT SCALE DRAWINGS). 4).WALL ASSEMBLY TO FOUNDATION: END NAIL 2-16d COMMON First wall studs shall be connected to the foundation,sill plate,or bottom plate with uplift ROOMS (SLEEPING) 30 4).The designer has not been engaged for construction supervision and assumes no connectors.Steel straps shall have a minimum embedment of 7 inches in concrete WALL FRAMING: STAIRS 40 responsibility for construction coordinating with these plans,nor responsibility for foundation and slab-on-grade,15 inches in masonry block foundations,or lapped under NAIL NAIL construction means,methods,techniques,sequences,or procedures,or for safety the plate and nailed in accordance with table 3.3b.When steel straps are lapped under the JOINT DESCRIPTION QTY. SPACING NOTES GAURDRAILS (ANY DIRECTION) 200 C precautions and programs in connection with the work.There are no warranties for a bottom plate,3 inch square washes shall be used with the anchor bolts.Anchor bolt EXPOSURE CATAGORY specific use expressed or implied in the use of these plans. spacing is to be spaced and sized in accordance to table 3.2a.In addition to spacing, TOP PLATE TO 2-16d COMMON PER FACE NAIL LOAD PATH SEE CONSTRUCTION ANDWIND PATH CONNECTION anchor bolts are to be spaced between 6-12 inches from the end of a sill plate and all TOP PLATE FOOT SEE NOTE:1 corners. TOP PLATES AT JOINTS FACE (ROOF - FOUNDATION) DETAIL PAGE 4 GENERAL NOTE PAGE 5).Refer to the Window and Door schedule for exterior openings. 4-16d COMMON INTERSECTIONS EA. SIDE NAIL NAILING SCHEDULE SEE GENERAL NOTE PAGE 6).The General Contractor is to ensure that masonry or prefabracted fireplaces meets 5).TYPE I EXTERIOR SHEARWALL CONNECTIONS: STUD TO 24" FACE EGRESS SEE FLOOR PLANS AND WINDOW SCHEDULE or exceeds manufacture's specifications and applicable codes. Type I exterior shear walls with a minimum of 7/16 inch wood structural panel on the exterior STUD 2 16d COMMON O.C. NAIL attached with 8d common nails at 6"o.c.at the panel edges and 12"o.c.in the field,and FIRE PROTECTION Syn.- 7).The General Contractor is to consult with the owner for all built-in items 1/2 inch gypsum wallboard on the interior attached with 5d cooler nails at 7"o.c.at panel HEADER TO 16d COMMON 16"O.C. FACE (SMOKE 4 CO2 DETECTORS) SEE FLOOR PLANS such as bookcases,shelving,pantry,closets,trims,etc. edges and 10"o.c.in the field shall be in accordance with the length requirements specified HEADER ALONG EDGES NAIL in table 3.15a-b. TOP OR BOTTOM 2-16d COMMON PER 2x4 STUD END TRUSS DESIGN N/A - STANDARD STICK FRAME CONSTRUCTION 8).Wind load requirements shall be taken into account during construction. PLATE TO STUD 3-16d COMMON PER 2x6 STUD NAIL ENERGY CALCULATIONS RESCHECK 3.6 RELEASE la O 6).TYPE II EXTERIOR SHEARWALL CONNECTIONS: BOTTOM PLATE TO: CLIMATIC & GEOGRAPHIC DESIGN CRITERIA V FOUNDATION NOTES: Type 11 exterior shearwalls shall meet the requirements of table 3.15a-b times the appropriate FLOOR JOIST,BAND JOIST, 2-16d COMMON PER FACE NAIL 1).The General Contractor and Mason to review plans,elevations,details and notes to length adjustment factors in table 3.16. END JOIST OR BLOCKING FOOT SEE NOTE: 1,2 GROUND WIND SEISMIC FROST WINTER ICESHIELD FLOOD determine intended heights of finished floor(s)above typical grade. 7).INTERIOR SHEARWALL CONNECTIONS: FLOOR FRAMING: SNOW SPEED DESIGN WEATHERING LINE TERMITE DECAY DESIGN UNDERLAYMENT HAZARDS Allowable sidewall lengths provided in table 3.14 shall be permitted to be increased when LOAD (MPH) CATEGORY DEPTH TEMP. REQUIRED 2).All footings to rest on undisturbed(Virgin)soil. interior shearwalls are used.Sheathing and connections shall be in accordance with JOINT DESCRIPTION NAIL NAIL NOTES MODERATE SLIGHT TO QTY. SPACING 45 LBS. 120 B SEVERE 3 FT. 11 NONE - 2.4.4.2 and 2.2.4 respectively. TO HEAVY MODERATE !y 3).Provide 1/2"expansion joint material between concrete slabs and abutting JOIST TO: PER TOE rY 9 8.CONNECTIONS AROUND EXTERIOR WALL OPENINGS: 4-8d COMMON FBI concrete or mason walls occurin in exterior or unheated interior areas. ) SILL,TOP PLATE OR GIRDER JOIST NAIL ROOF SHEATHING REQUIREMENTS FOR WIND LOADS: Header and/or girder connections shall be attached with uplift connections in accordance BRIDGING EACH TOE 4).An new concrete walls being attached to existing concrete structure shall 2-8d COMMON NAIL SPACING NAIL SPACING AT INTERMEDIATE Y 9 9 with table 3.5.Window sill plates shall be have steel connectors in accordance with table TO JOIST END NAIL SHEATHING LOCATION NOTES be installed with#4 re-bar,18"Ion at 12"o.c..Use approved epoxy for installation. AT PANEL EDGES SUPPORTS IN THE PANEL FIELD 9 PP P xY 3.5. BLOCKING EACH TOE 5).Unless otherwise noted,all slabs on grade to be 2500 p.s.{..Concrete to be TO JOIST 2-8d COMMON END NAIL 4'PERIMETER EDGE ZONE 8d COMMON @ 6"O.C. 8d COMMON @ 6"O.C. SEE NOTES:1,3 ^ - .CATHEDRAL CEILING ASSEMBLY: BLOCKING TO: EACH TOE °e e poured on 4 inch thick sand or gravel fill with 6x6 wire mesh reinforcing.Interior slabs 9). INTERIOR ZONE 8d COMMON 6"O.C. 8d COMMON 12"O.C. SEE NOTES:1 (BOTH FIELDS) to be minimum 3-1/2 inch thick.All fill to be compacted to 95%relative density with Where a ridge is to be used as a structural beam,the rafters shall either be notched and 3-16d COMMON NOTE:2 FOR PANEL FIELD 6"maximum lifts(layers). anchored on top of the beam or slope connectors shall be attached to each rafter-to-ridge SILL OR TOP PLATE BLOCK NAIL �T� O along the open ceiling part of the building.Connections to the ridge and wall shall be be LEDGER STRIP EACH FACE GABLE ENDWALL RAKE AND RAKE TRUSS 8d COMMON @ 4"O.C. 8d COMMON @ 4"O.C. SEE NOTES:1,3 W 6).Crawl spaces to be provided with a minimum 18"x24"access opening.Install one attached with the above requirements. TO BEAM 3-16d COMMON JOIST NAIL NOTES A W 8x16 cast iron foundation vent for every 150 sq.ft.of area. h�l DECK AND COVERED PORCH NOTES: JOIST ON LEDGER 3-8d COMMON PER TOE ( '� 7).Dampproof exterior of foundation with bituminous coating as per section R406 of TO BEAM JOIST NAIL THESE NOTES ARE ONLY TO BE REFERRED TO IF MENTIONED IN SCHEDULE NOTES ONLY, v N.Y.S.Residential Construction Code.A 6-mil polyethylene film shall be applied over 1).Unless otherwise noted,all framing material to be#1 ACQ pressure treated lumber. BAND JOIST 3-16d COMMON PER END Ln the below grade portion of exterior walls prior to backflling. All fasteners,hangers and anchors to be galvinized or stainless steel. TO JOIST JOIST NAIL 1).For roof sheathing within 4 feet of the perimeter edge of the roof,including 4 feet on each side of the roof peak, UJ Z ON �:) BAND JOIST TO. PER TOE NAIL the 4 foot perimeter edge zone attachments required shall be used. 8).Drainage as per section R405 of N.Y.S.Residential Construction Code. 2).Girders for deck joists to be bolted to each post with washers and nuts. SILL OR TOP PLATE 2-16d COMMON FOOT SEE NOTE:1 �/ l V Girders on concrete piers shall be anchored with proper steel connectors anchored 2).Tabulated 12 inch o.c.nail spacing assumes sheathing attached to rafter/truss framing members with G>0.49. FRAMING NOTES into concrete with a minimum 1/2"dia x 7"long anchor bolt with washers and nuts. ROOF SHEATHING. For framing members with<0.42<G<0.49,the nail spacing shall be reduced to 6 inches o.c. O �� 1).All framing techniques and methods as prescriptive design of 1995 SBC High Wind 3).Posts supporting girders shall be anchored to a 12"x12"x12"thick concrete footing. JOINT DESCRIPTION QTY_ SPACING 3).Tabulated 4 inch o.c.nail spacing assumes sheathing to rafter/truss framing members with G>0.49.For Edition Wood Framing Construction Manual. Use a minimum 1/2"dia x 7"long anchor bolt with washers and nuts.Footings Shall be 3 ft. framing members with 0.42<G<0.49,the nail spacing shall be reduced to 3 inches o.c. below grade.Porches with covered roofs shall have 12"dia.concrete piers for the girders. STRUCTURAL PANEL 8d AS PER TABLE 3.8 WALL SHEATHING REQUIREMENTS FOR WIND LOADS 2).Unless otherwise noted,all framing and structural wood material to be#2+BTR. WFCM-SBC Douglas Fir. 4).Deck joists to have blocking at 8'0 o.c.. CEILING S H EATH I N G: SHEATHING LOCATION NAIL SPACING NAIL SPACING AT INTERMEDIATE O NOTES r ' 3).Floors,walls,ceilings and rafters to be spaced at 16 inches o.c.unless noted 5).A minimum of 10 inch flashing shall be installed between the building and ledger. NAIL NAIL AT PANEL EDGES SUPPORTS IN THE PANEL FIELD otherwise. JOINT DESCRIPTION SEE NOTES:1,3 BOTH FIELDS O Ledger to be fastened to building with 1/2"dia.bolts with washers and nuts QTY. SPACING 4'EDGE ZONE Sd COMMON @ 6"O.C. Sd COMMON @ 12"O.C. ( ) where needed. GYPSUM 7" O.C.EDGE NOTE:2 FOR PANEL FIELD 4).Unless otherwise noted,all bearing wall headers to be(2)2x10#2+BTR.Doug.Fir. 5d COOLERS INTERIOR ZONE 8d COMMON 6"O.C. 8d COMMON 12"O.C. SEE NOTE:3 Bearing all headers to have 2 jack studs and 2 full length studs on each side of all WALLBOARD 10"O.0.FIELD @ @ 9 ( )1 ( ) 9 6).Concrete piers shall be a minimum 6"above grade. openings.LVL headers to have(3)jack studs and(2)full length studs on each side of WALL SHEATHING: NOTES openings.Bearing wall window sills shall also have(2)window sill plates for 2x4 wall 7).All joists to be supported with hangers and anchors.Each Joist shall also be anchored openings between 4'1 and 6'0 and 2x6 wall openings between 5'11 and 8'9.Provide fire to girder(s). JOINT DESCRIPTION NAIL NAIL THESE NOTES ARE ONLY TO BE REFERRED TO IF MENTIONED IN SCHEDULE NOTES ONLY. and blocking where applicable. QTY. SPACING 8).Covered Roofs shall be assembled and anchored the same manner as a typical building. STRUCTURAL 8d COMMON AS PER TABLE 3.9 1).For wall sheathing within 4 feet of the corners,the 4 foot edge zone attachment requirements shall 5).All flush beams/headers to be installed with heavy duty galvinized hangers and PANELS WFCM-SBC be used. anchors where applicable to all connecting joists. PLUMBING NOTES 7/16"OSB 3"O.C.EDGE 6d COMMON 2.Tabulated 12 inch o.c.nails spacing assumes sheathing attached to stud framing members with 6).Double up floor joists under walls that run parallel to the floor joist and under bathtubs. 1).All water supply,drainage and venting to be installed as per N.Y.S.Residential PLYWOOD 6"O.C.FIELD ) P g g g G>0.49.For framing members with 0.42<G<,the nail spacings shall be reduced to 6 inches o.c. Floors to have ceramic the installed shall be verified for proper load capacity unless noted Construction Code. GYPSUM 5d COOLERS 7 O.C.EDGE on plans. WALLBOARD 1 10"O.C.FIELD 3).For exterior panel siding,galvinized box nails shall be permitted to be substituted for common nails. 2).Verify septic system with the Engineer for Suffolk County Health Department approval. FLOOR SHEATHING: NOTE: 7).Provide blocking/bridging in floor joists at 8'0 o.c..Use solid blocking in floor joists under all bearing walls. 3).If wall studs,plates or joists are cut out during installation for any plumbing related work, JOINT DESCRIPTION NAIL NAIL CONTRACTOR TO PROVIDE SOIL TEST TO VERIFY q �q provide adequate bracing and plates to protect and secure the structure.Verify with the QTY. SPACING DRAWN BY: M H 8).Provide insulation baffles at eave vents between rafters.Install draft blocking as state code and manufacture's recommendation for maximum hole size and spacing permitted. STRUCTURAL PANELS Sd COMMON 6"O.C.EDGE EXISTING CONDITIONS, MINIMUM 3000# CAPACITY. needed. 1"OR LESS 12"O.C.FIELD 1 PROVIDE 5/8"TYPE-X SHEETROCK FIRE STOPPING AT 10'0 MAXIMUM DISTANCES FOR NON ACCESSIBLE AREAS. HVAC SYSTEM NOTES )• 9).Unless otherwise noted,all roofs and walls to have a minimum 1/2"thick,4-ply Fir NOTES: 2).USE SIMPSON HANGERS AND ANCHORS WITH Z-MAX TRIPPLE PROTECTIVE COATING FOR CONTACT WITH ACQ. 12/15/2013 CDX exterior sheathing grade plywood.Plywood to cover over plates and headers. 1).Mechanical subcontractor is responsible for adhearing to all applicable codes and safety 3).INSTALL 1 -Co2 DETECTOR IN ADDITION TO SMOKE ALARMS PER FLOOR. requirements. THESE NOTES ARE ONLY TO BE REFERRED TO IF 10).Unless otherwise noted use 3/4"thick T&G PTS Fir or Advantech plywood subfloor MENTIONED IN SCHEDULE NOTES ONLY. Section king shall l FIRE provided to REQUIRED adhered with PL400 adhesive and screwed to floor joists.Finished floor to be installed 2)•HVAC subcontractor is to fully coordinate all system data and requirements with the Fireblocking shall be provided to cut off all concealed draft openings(both vertical and horizontal) SCALE: 1/4rr _ 1r_Orr equipment supplier. and to form an effective fire barrier between stories,and between a top story and the roof space. over subfloor as per manufacture's instructions. 1).Nailing requirements are based on wall sheathing 3).HVAC subcontractor to provide final system layout drawing and submit it to the General nailed 6"on-center at the panel edge.If wall sheathing Fireblocking shall be provided in wood-frame construction in the following locations. 11).All bathroom walls to have 1/2"thick moisture-resistant sheetrock.Garage walls and Contractor and owner for final review and approval. is nailed 3"on-center at the panel edge to obtain higher ceilings and over furnace to have 5/8"thick type-x sheetrock.All other parts of building shear capacities,nailing requirements for structural 1).In concealed spaces of stud walls and partitions,including furred spaces,at the ceiling and floor to have regular 1/2"sheetrock.All walls to be taped and finished. ELECTRICAL NOTES: members shall be doubled,or alternate connectors, levels.Concealed horizontal furred spaces shall also be fireblocked at intervals not exceeding 10 SHEET NO: such as shear plates,shall be used to maintain load path.. feet.Batts or blankets of mineral or glass fiber shall be allowed as freblocking in walls constructed 12).All roof with a pitch less than 4:12 shall be installed with an Ice&Water barrier or 1).All electrical to be installed as per N.Y.S.Residential Construction Code. using parallel rows of studs or staggered studs. approved equal.Flat roofs shall be applied with a Fiberglas base sheet with an EPDM 2).When wall sheathing is continuous over connected Of NEW torch down type material over. 2).All electrical work shall be approved by a qualified Underwriter, members,the tabulated number of nails shall be permitted 2).At all interconnections between concealed vertical and horizontal spaces such as occur at soffits, P� DEE"o Y0. to be reduced tot-16d nail per foot. drop ceilings and cove ceilings. 10D 'hps 13).All sill plates and wood in contact with concrete to be pressure treated.Sill plates to 3).Install Smoke detectors and Carbon Monoxide detectors throughout as per section R317 be installed with a foam sill gasket and cop-r-tex termite shield or approved equal. of N.Y.S.Residential Construction Code. 3).In concealed spaces between stair stringers at the top and bottom of the run. Enclosed spaces * W under stairs shall comply with Section R314.8,N.Y.S.Residential Code. w _2 Q4).At openings around vents,pipes and ducts at ceiling and floor level,to resist the free passage of flame and products of combustion. F� h 5).For the fireblocking of chimneys and fireplaces,refer to Section R1001.16.N.Y.S.Residential Code. AROFESS�