Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
38430-Z
Town of Southold Annex 4/29/2014 P.O.Box 1179 �e 54375 Main Road Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 36879 Date: 4/29/2014 THIS CERTIFIES that the building GENERATOR Location of Property: 795 Oyster Ponds Ln, Orient, SCTM#: 473889 Sec/Block/Lot: 25.-1-2 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this officed dated 10/8/2013 pursuant to which Building Permit No. 38430 dated 10/21/2013 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: ACCESSORY GENERATOR AS APPLIED FOR The certificate is issued to Reeves Jr,Robert&Reeves,Marjorie (OWNER) of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 38430 04-23-2014 PLUMBERS CERTIFICATION DATED Cr Authorized Signature TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE ' SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 38430 Date: 10/21/2013 Permission is hereby granted to: Reeves Jr, Robert & Reeves, Marjorie 795 Oyster Ponds Ln PO BOX 215 Orient, NY 11957 To: install an Accessory Generator as applied for At premises located at: 795 Oyster Ponds Ln, Orient SCTM # 473889 Sec/Block/Lot# 25.-1-2 Pursuant to application dated 10/8/2013 and approved by the Building Inspector. To expire on 4/22/2015. Fees: ACCESSORY $100.00 ELECTRIC $85.00 CO -ACCESSORY BUILDING $50.00 Total: $235.00 Building Inspector form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be.filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings,property lines,streets,and unusual natural or topographic features. 2. Final Approval from Health Dept.of water supply and sewerage-disposal(S-9 form). 3. Approval of'electrical installation from Board of Fire Underwriters. 4. Sworn statement Tom plumber certifying that the solder used in system contains less than 2/10 of 1%lead. 5. Commercial building,industrial building,multiple residences and similar buildings and installations,a certificate of Code Compliance from:architect or engineer responsible for the building. 6. Submit'Planning Board Approval-ofcompleted site plan requirements. 8. For existing buildings(prior to April 9,1957)"non-conforming uses,or buildings and"pre-existing"land uses: 1. Accurate survey of property showing all property lines,streets,building and unusual natural or topographic features. 2. A property completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied,the Building Inspector'shall state the reasons therefor in writing to the applicant. C. Fees I. Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00, Alterations to dwelling$50.00, Swimming pool$50.00,Accessory building$50.00,Additions to accessory building$50.00, Businesses$50.00. 2. Certificate of Occupancy on Pre-existing Building- $106.00 3. Copy of Certificate of Occupancy-$.25 4. Updated Certificate of Occupancy- $50.00 .5. Temporary Certificate of Occupancy-Residential $15.00,Commercial $15.00 Date. New Construction: Old or Pre-existing Building: (check one) Location of Property: House No. Street Hamlet Owner orOwners of Property: Suffolk County Tax Map No 1000,'Section ' '.Block f Lot. `Subdivision :.Filed Map. Lot: ,.. Permit No._ �..�?jQ Date of Permit. Applicant_ 1Qtoe, C.[ecfe-t L Health Dept.Approval: Underwriters Approval: Planning Board-Approval: . Request for: Temporary Cerfificate- Final Certificate: ✓ (check one) Fee Submitted: Applican pF SO!/ryol Town Hall Annex Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 1179 CA roper.riche rt(a-town.southold.ny.us Southold,NY 11971-0959 Cow,� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION Issued To: Robert Reeves Address: 795 Oyster Ponds Ln City: Orient St: NY Zip: 11957 Building Permit* 38430 Section: 25 Block: 1 Lot: 2 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: Glens Electric License No: 4770-me SITE DETAILS Office Use Only Residential X Indoor Basement Service Only Commerical Outdoor X 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures HID Fixtures Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Fluorescent Fixture Pumps Transformer Appliances Dryer Recpt Emergency Fixture Time Clocks Disconnect Switches Twist Lock Exit Fixtures TVSS Other Equipment: 17KW standby generator with 150a transfer switch Notes: Inspector Signature: c-�,C� —. Date: April 23 2014 81-Cert Electrical Compliance Form.xls P'�LD DATY, COMM3q TB FOUNDAVON(IST) FOUNDATION(ZND) 1 ROUGH FP49WQ& PLUMING IMULATION M No Y* STATE ENERGY COB FINAL ADDITIONAL coo MINTS C ,C o • rt U TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following, before applying? TOWN HALL Board of Health SOUTHOLD, NY 11971 4 sets of Building Plans TEL: (631) 765-1802 Planning Board approval FAX: (631) 765-9502 Survey South oldTown.NorthFork.net PERMIT NO. Check Septic Form N.Y.S.D.E.C. Trustees WL__1 C.O.Application \11 Flood Permit Examined o 20 Single& Separate — $ Storm-Water Assessment Form Contact:Approved /a ,20� DG IiFPf- Mail to: Disapproved a/c OF SUH1011) Phone: � �PS� Expiration ir, 20_ � Building Inspector APPLICATION FOR BUILDING PERMIT Date /o �� , 20/3 INSTRUCTIONS a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans, accurate plot plan to scale. Fee according to schedule. b. Plot plan showing location of lot and of buildings on premises, relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application, the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e. No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim, the Building Inspector may authorize, in writing,the extension of the permit for an addition six months. Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York, and other applicable Laws, Ordinances or Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances, building code, housing code, and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. U.PA N G Y ��1 (Signat e f applicant or name, if a corporation) xw . IS UNLAW W - `������ 4 (�- :'�, i' Y F�`, (Mxi ng ad ess o `applican ` . �, TE�� ;/ 3 B.P. #.�sQ State whether applicant is crier' lessee gent, a c itect, engineer, gen��'a7 c r c or, electrici lumber or builder FEE: ---•—BY OTIFY BUILDING DE ART t+ 765-1802 8 A Name of owner of premises ! /_ �OLL OWING INSPECTIONS: IFtED (As on the tax roll or tp D CONCRETE If applicant is a corporation, signature of duly authorized officer 2. ROUGH-FRAMING,PLUMBING,. ©Gt/ft./le;P� STRAPPING, ELECTRICAL&CAULK,N (Name and title of corporate officer) 3. INSULATION Builders License No. 41 FINAL-CONSTRUCTION &ELECTRICAL Plumbers License No. MUST BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE Electricians License No. -/7-;Zp –Orr REQUIREMENTS OF THE CODES OF NEW Other Trade's License No. YORK STATE. NOT RESPONS BLE FOR DESIGN OR CONSTRUCTION ERRORS. 1. Location of land on which proposed work ww 1 e �A����A� © gNS 6-'F House Number treet Hamlet County Tax Map No, 1000 Section Block Lot Subdivision Filed Map No. Lot i 2. State existing use and occupancy of premises and intended use and occupancy ro a. Existing use and occupancy p Y of p posed construction: b. Intended use and occupancy 3. Nature of work (check which applicable): New Building Addition Repair Removal__Demolition Alteration___ Other Work 4. Estimated Cost Fee (Description) ( filing this application) 5. If dwelling, number of dwelling units Number of dwelling units e n each floor If garage, number of cars 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of existing structures, if any: Front Height Rear Depth Number of Stories Dimensions of same structure with alterations or additions: Front Depth Height Rear Number of Stories 8. Dimensions of entire new construction: Front Height Rear Depth Number of Stories 9. Size of lot: Front Rear Depth 10. Date of Purchase Name of Former Owner 11. Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law, ordinance or regulation? YES NO 13. Will lot be re-graded? YES NO Will excess fill be removed from premises? YES NO 14. Names of Owner of premises Name of Architect Address Phone No. Name of Contractor Address Phone No Address Phone No. 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO * IF YES, SOUTHOLD TOWN TRUSTEES & D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey, to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. 18. Are there any covenants and restrictions with respect to this property? * YES NO * IF YES, PROVIDE A COPY. STATE OF NEW YORK) SS: COUNTY OF (Name of individual signing contract)above named,being duly sworn, deposes and says that(s)he is the applicant (S)He is the NotaTY ubl cr S ate of Now York No. 01 SU6185050 (Contractor, Agent, Corporate Officer, etc.) �OlUl commission EApircu r Pc ii 14,'� 7 f of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief, and that the work will be performed in the manner set forth in the application filed therewith. Sworn to before me this day of 20 l ldl�( Notary Public Signat e of App scant C� 1 OF SO�ryDl 16 41 Town Hall Annex Telephone(631)765-1802 ' 54375 Main Road � • O ft g p 5 aP.O.Box 1179 rOQer.rCheOWSOU 0n nV us Southold,NY 11971-0959 BUILDING DEPARTMENT TOWN OF SOUTHOLD APPLICATION FOR ELECTRICAL INSPECTION REQUESTED BY. Date: Company Name: s JCZ s Name: c� License No.: q o Address: o Phone No.: _ 6 JOBSITE INFORMATION: (*Indicates required information) *Name: 12 RdFlt!'i C. IRR *Address: �iLrzj o. S TE)e i� *Cross Street: *Phone No.: Permit No.: _ 4z ci 5 o Tax-Map District: 1000 Section. Z _ Block:_ Lot: Z *BRIEF DESCRIPTION OF WORK(Please Print Clearly) J � �. "=e--%7Z kcal 'A'°0e'eqA (Please Circle All That Apply) *Is job ready for inspection: YES/ Rough In Final *Do-you need a Temp Certificate: YES/ Temp Information.(if needed) *Service Size: 1 Phase 3Phase 100 150 200 300 350 400 Other *New Service: Re-connect Underground Number of Meters Change of Service Overhead Additional Information: PAYMENT DUE WITH APPLICATION 82=RRequest for Inspection Form �' .�`:. _ ,/STb-MM'+n.!.a:�+i4wMs�?+3'#yr"iMUro4'./�b�' _ _.°"v:+41n-'oR"'/^�•'^4i./naa-rrsii+.s - t - M- !� ,x�-' G i 7777 View ON NZ Li IJ Mw IL # u ] W tL f - -�• icy"'�pc,�y- �r. � �; � q� err e°� ` arum •�Y - -�� � x n �H - + It _ r s's- ey is .�.�' y„ '?-:-- i 3 �5r��y.� 2� � .�y ti3r`,� +•`�.i �` -�� *'�3.}. r� "� � ��'�>..�� -:r �+i'„+r �,#� 4,�,-��"•` �:+. $'� � Xis, _ _ s F xx` y � c' p GENERAC' 14/17/20kW GUARDIAN® SERIES Residential Standby Generators Air-Cooled Gas Engine INCLUDES: Standby Power Rating • True Power" Electrical Technology Models 006240-0, 006241-0, 006247-0 (Steel-Bisque) - 14 kW 60Hz • Two Line LCD Multilingual Digital Models 006242-0, 006248-0 (Steel- Bisque) - 7 kW 60H Evolution'" Controller (English/Spanish/ Models 006243-0, 006249-0 (Aluminum-Gray) - 17 kW 60Hz French/Portuguese) Models 006244-0, 006250-0 (Aluminum-Gray) -20 kW 60Hz • Two Transfer Switch Options Available: 100 Amp Pre-Wired Switch or 200 Amp Smart Switch. See Page 4 for Details. • Electronic Governor • External Main Circuit Breaker, System Status & Maintenance Interval LED Indicators • Sound Attenuated Enclosure • Flexible Fuel Line Connector • Composite Mounting Pad • Natural Gas or LP Gas Operation C L O uS LISTED • 5 Year Limited Warranty Note:CUL certification only applies to unbundled units and units packaged with pre-wired switches. • Capability to be installed within 18" of a building* Units packaged with the Smart Switch are UL certified in the USA only. "Only if located away from doors,windows and fresh air intakes,and unless otherwise directed by local codes. FEATURES O INNOVATIVE DESIGN&PROTOTYPE TESTING are key components O SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION. of GENERAC'S success in"IMPROVING POWER BY DESIGN." But it This state-of-the-art power maximizing regulation system is standard on doesn't stop there. Total commitment to component testing,reliability all Generac models. It provides optimized FAST RESPONSE to changing testing,environmental testing,destruction and life testing,plus testing load conditions and MAXIMUM MOTOR STARTING CAPABILITY by to applicable CSA,NEMA,EGSA,and other standards,allows you to electronically torque-matching the surge loads to the engine. Digital choose GENERAC POWER SYSTEMS with the confidence that these voltage regulation at±1%. systems will provide superior performance. o TRUE POWER" ELECTRICAL TECHNOLOGY: Superior harmonics O SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer and sine wave form produce less than 5% Total Harmonic Distortion for network provides parts and service know-how for the entire unit,from the utility quality power. This allows confident operation of sensitive electronic engine to the smallest electronic component. equipment and micro-chip based appliances,such as variable speed HVAC systems. O GENERAC TRANSFER SWITCHES. Long life and reliability are O TEST CRITERIA: synonymous with GENERAC POWER SYSTEMS. One reason for this PROTOTYPE TESTED NEMA MG1-22 EVALUATION confidence is that the GENERAC product line includes its own transfer SYSTEM TORSIONAL TESTED MOTOR STARTING ABILITY systems and controls for total system compatibility. GENERAC® r ' GENERAC® 14/17/20kW features and benefits Engine •Generac(OHVI)design Maximizes engine"breathing"for increased fuel efficiency. Plateau honed cylinder walls and plasma moly rings helps the engine run cooler,reducing oil consumption resulting in longer engine life. •"Spiny-lok"cast iron cylinder walls Rigid construction and added durability provide long engine life. -Electronic ignition/spark advance These features combine to assure smooth,quick starting every time. -Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance,less maintenance and longer engine life. Now featuring up to a 2 year/200 hour oil change interval. •Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil. -High temperature shutdown Prevents damage due to overheating. Generator -Revolving field Allows for a smaller,light weight unit that operates 25%more efficiently than a revolving armature generator. •Skewed stator Produces a smooth output waveform for compatibility with electronic equipment. -Displaced phase excitation Maximizes motor starting capability. -Automatic voltage regulation Regulates the output voltage to±1%prevents damaging voltage spikes. •UL 2200 listed For your safety. Transfer Switch -Fully automatic Transfers your vital electrical loads to the energized source of power. •Pre-wired,color-coded conduits Ensures the easiest,trouble-free installation. (Pre-wired switches only) •DPM Technology Digital Power Management Technology allows for the smart control of two air conditioners without any additional (Smart Switch only) items. -Remote mounting Mounts near your existing distribution panel for simple,low-cost Evolution`" Controls •Auto/Manual/Off illuminated buttons Selects the operating mode and provides easy,at-a-glance status indication in any condition. • Sealed,raised buttons Smooth,weather-resistant user interface for programming and operations. -Utility voltage sensing Constantly monitors utility voltage,setpoints 60%dropout,80%pick-up,of standard voltage. -Generator voltage sensing Constantly monitors generator voltage to ensure the cleanest power delivered to the home. •Utility interrupt delay Prevents nuisance start-ups of the engine,adjustable 2-1500 seconds from the factory default setting of 10 seconds by a qualified dealer. •Engine warm-up Ensures engine is ready to assume the load,setpoint approximately 5 seconds. -Engine cool-down Allows engine to cool prior to shutdown,setpoint approximately 1 minute. -Programmable seven day exerciser Operates engine to prevent oil seal drying and damage between power outages by running the generator for 12 minutes every week. -Smart battery charger Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. -Main line circuit breaker Protects generator from overload. •Electronic governor Maintains constant 60 Hz frequency. Unit -Weather protective enclosure Ensures protection against mother nature and can withstand winds up to 150mph.Hinged key locking roof panel for security. Lift-out front for easy access to all routine maintenance items.Electrostatically applied textured epoxy paint for added durability. -Enclosed critical grade muffler Quiet,critical grade muffler is mounted inside the unit to prevent injuries. -Small,compact,attractive Makes for an easy,eye appealing installation. -SAE Sound attenuated enclosure ensures quiet operation. Installation System •1ft.(305mm)flexible fuel line connector Easy installation. .Composite mounting pad GENERAC' 14/17/20kW specifications Model 006240-0,006241-0, 006242-0,006243-0,006248-0,006249-0 006244-0,006250-0 006247-0,(14 kW) (17 kW) (20kW) Rated Maximum Continuous Power Capacity(LP) 14,000 Watts' 17,000 Watts' 20,000 Watts' Rated Maximum Continuous Power Capacity(NG) 14,000 Watts' 16,000 Watts' 18,000 Watts` Rated Voltage 240 240 240 Rated Maximum Continuous Load Current—240 Volts(LP/NG) 58.3/58.3 70.8/66.6 83.3/75 Total Harmonic Distortion Less than 5% Less than 5% Less than 5% Main Line Circuit Breaker 60 Amp 65 Amp 90 Amp Phase 1 1 1 Number of Rotor Poles 2 2 2 Rated AC Frequency 60Hz 60Hz 60Hz Power Factor 1.0 1.0 1.0 Battery Requirement(not included) Group 26R,12 Volts and 525 CCA Minimum Unit Weight(Pounds/Kilos) 435/197.3 471/213.6(Steel).437/198.2(Aluminum) 451/204.6 Dimensions(L x W x H)in./mm 48 x 25 x 29/1218 x 638 x 732 Sound output in dB(A)at 23 ft.(7m)with generator operating at normal load*' 66 66 66 Sound output in dB(A)at 23 ft.(7m)with generator in Quiet Test"low-speed exercise mode"" NA 60 60 Er Type of Engine GENERAC OHVI V-TWIN GENERAC OHVI V-TWIN GENERAC OHVI V-TWIN Number of Cylinders 2 2 2 Displacement 992cc 992cc 999cc Cylinder Block Aluminum w/Cast Iron Sleeve Valve Arrangement Overhead Valve Overhead Valve Overhead Valve Ignition System Solid-state w/Magneto Solid-state w/Magneto Solid-stale w/Magneto Governor System Electronic Electronic Electronic Compression Ratio 9.5:1 9.5:1 9.5:1 Starter 12 Vdc 12 Vdc 12 Vdc Oil Capacity Including Filter Approx.1.9 Qts./1.8L Approx.1.9 Ots./1.81- Approx.1.9 Qts./1.8L Operating RPM 3,600 3,600 3,600 Fuel Consumption Natural Gas ft'/hr(m'/hr) 112 Load 177(5.01) 193(5.47) 205(5.8) Full Load 279(7.9) 312(8.83) 308(8.72) Liquid Propane t13/hr(gal/hr)[Liters/hr1 112 Load 67.2(1.85)[6.991 72.4(1.99)[7.531 75.6(2.08)[7.871 Full Load 111.6(3.07)[11.611 130(3.57)[13.531 140(3.85)[14.571 Note:Fuel pipe must be sized for full load. Required fuel pressure to generator fuel inlet at all load ranges-3.5-T water column(7-13mm mercury)for natural gas,10-12"water column(19-22mm rne(cury)for LP gas.For Btu content,multiply ft3/hr x 2500(LP)or ft3/hr x 1000(NG).For Megajoule content,multiply m3/hr x 93.15(LP)or m'/hr x 37.26 INS) 2-Line Plain Text Multilingual LCD Display Simple user interface for ease of operation. Mode Buttons: Auto Automatic Start on Utility failure.7 day exerciser. Manual Start with starter control,unit stays on.If utility fails,transfer to load takes place. Off Stops unit.Power is removed.Control and charger still operate. Ready to Run/Maintenance Messages Standard Engine Run Hours Indication Standard Programmable start delay between 2-1500 seconds Standard(programmable by dealer only) Utility Voltage Loss/Return to Utility Adjustable From 140-171V/190-216V Future Set Capable Exerciser/Exercise Set Error Warning Standard Run/Alarm/Maintenance Logs 50 Events Each Engine Start Sequence Cyclic cranking:16 sec.on,7 rest(90 sec.maximum duration). Starter Lock-out Starter cannot re-engage until 5 sec.after engine has stopped. Smart Battery Charger Standard Charger Fault/Missing AC Warning Standard Low Battery/Battery Problem Protection and Battery Condition Indication Standard Automatic Voltage Regulation with Over and Under Voltage Protection Standard Under-Frequency/Overload/Stepper Overcurrent Protection Standard Safety Fused/Fuse Problem Protection Standard Automatic Low Oil Pressure/High Oil Temperature Shutdown Standard Overcrank/Overspeed(@ 72Hz)/RPM Sense Loss Shutdown Standard High Engine Temperature Shutdown Standard Internal FaulUlncorrect Wiring Protection Standard Common External Fault Capability Standard Field Upgradable Firmware Standard `Sound levels are taken from the front of the generator.Sound levels taken from other sides of the generator may be higher depending on installation parameters.Rating definitions-Standby:Applicable for supplying emergency power for the duration of the utility power outage. No overload capability is available for this rating. (All ratings in accordance with BS5514,IS03046 and DIN6271). 'Maximum wattage and current are subject to and limited by such factors as fuel Btu/megajoule content,ambient temperature,altitude,engine power and condition,etc. Maximum power decreases about 3.5 percent for each 1,000 feet(304.8 meters)above sea level;and also will decrease about 1 percent for each 6°C(10°F)above 16"C(60°F). r' GENERAL' 14/17/20kW switch options li Pre-wired Features Model 006240-0(14 kW) 006242-0(17kW) available on 14&17kW models only No.of Poles 2 2 • Electrically operated,mechanically-held contacts for fast,positive Current Rating(Amps) too 100 connections. Voltage Rating(VAC) 250 120/240,10 Utility Voltage Monitor(Fixed)* • Rated for all classes of load,100%equipment rated,both inductive and -Pick-up 60% 60% resistive. -Dropout 60% 60% Return to Utility* approx.15 sec. approx.15 sec. • 2 pole,250 VAC contactors. Exercise weekly for 12 minutes* Standard Standard • 30 millisecond transfer time. UL Listed Standard standard Total of Pre-wired Circuits 14 16 • Dual coil design. No.15A 120V 4 5 No.20A 120V 6 5 • Main contacts are silver plated or silver alloy to resist welding and sticking. No.20A 240V 1 1 • NEMA 1 (indoor rated)enclosure is standard on the pre-wired switch. No.30A 240V - - No.40A 240V 1 1 • Pre-wired 30 foot(9.1 meter)whip to connect to the provided 5 foot pre- No.50A 240V - 1 wired whip and external connection box. Circuit Breaker Protected Available RMS Symmetrical • Pre-wired 2 foot(0.61 meter)whip,color coded to connect into the Fault Current @ 250 Volts 10,000 10,000 existing electrical panel. *Function of Evolution Controller U- Dimensions Mechanical Dlmenslons E Height Width Amps H1 H2 W1 W2 Depth H2 M7 100 23.5 in 26.4 in 8.3 in 12.6 in 6.3 597mm 671.7mm 211mm 320.7mm 159.6mm o Wire Ranges — Amps Conductor Lug Neutral Lug Ground Lug 100 210-#14 2/0-#14 2/0-#14 wr Smart Switch Features Model 006241-0(14kW)/006243-0(17kW)/006244-0(20kW) • Includes Digital Power Management Technology standard(DPM). No.of Poles 2 Current Rating(Amps) 200 • Intelligently manages two air conditioner loads with no additional Voltage Rating(VAC) 120/240,10 hardware. Utility Voltage Monitor(Fixed)* • Up to four more large(120/240VAC)loads can be managed when -Pick-"p 80% used in conjunction with Power Management Modules(PMM**). Dropout B0%Return to Utility* approx.13 sec. • Electrically operated,mechanically-held contacts for fast,clean Exercise weekly for 12 minutes* Standard Connections. UL Listed Standard Enclosure Type NEMA/UL 3R • Rated for all classes of load,100%equipment rated,both inductive Withstand Rating(Amps) 22,000 and resistive. Lug Range 250MCM-#6 • 2 pole,250 VAC contactors. *Function of Evolution Controller • Service equipment rated,dual coil design. • Rated for both aluminum and copper conductors. • NEMA/UL 3R aluminum outdoor enclosure. • Main contacts are silver plated or silver alloy to resist welding and sticking. **Note:PMM starter kit is required prior to using the modules. Dimensions 200 Amps 120/240,to Open Transition Service Rated Height Width Depth H1 H2 W1 W2 Inches 27.24 30.0 11.4 1 13.5 1 7.09 mm 692.0 1 762.4 289,0 1 343.0 1 180.0 DEPM I-yn I GENERAC-:. mom. 14/17/20kW available accessories Model# Product Description 005819-0 26R Wet Cell Battery Every standby generator requires a battery to start the system.Generac offers the recommended 26R wet cell battery for use with all air-cooled standby product. 006212-0 Cold Weather Kit If the temperature regularly falls below 32°F(0°C),install a cold weather kit to maintain optimal battery and oil temperatures. Kit consists of a battery warmer and oil filter heater with built-in thermostats. 005621-0 Auxiliary Transfer Switch Contact The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical load Kit you may not need.Not compatible with 50 amp pre-wired switches. 005839-0-Bisque Fascia Base Wrap Kit* The fascia base wrap snaps together around the bottom of the new air cooled generators.This offers 005666-0-Gray (Standard on 20k" a sleek,contoured appearance as well as offering protection from rodents and insects by covering the lifting holes located in the base. 005703-0-Bisque If the generator enclosure is scratched or damaged,it is important to touch-up the paint to protect from 005704-0-Gray Paint Kit* future corrosion.The paint kit includes the necessary paint to properly maintain or touch-up a generator enclosure. 006484-0-14&17kW Generac's scheduled maintenance kits provide all the hardware necessary to perform complete routine 006485-0-20kW Scheduled Maintenance Kit maintenance on a Generac automatic standby generator. 005928-0 Wireless Remote Completely wireless and battery powered,Generac's wireless remote monitor provides you with instant status information without ever leaving the house.Not compatible with CorePower or EcoGen systems. Remotely control generator functions with the advanced model's LCD display.In addition to remote 005951-0 Advanced Wireless Remote testing of the generator,set the excercise cycle and maintenance interval reminders.Not compatible with CorePower or EcoGen systems. The PMM Starter Kit consists of a 24VAC,field installed transformer that enables the use of the 24VAC 006199-0 PMM Starter Kit Power Management Modules(PMMs)and one PMM.The standard controller(without starter kit)can control two HVAC loads with no additional hardware.Not compatible with pre-wired switches. Power Management Module(50 Power Management Modules are used in conjunction with the Smart Switch to increase its power 006186-0 Amps) management capabilities.It gives the Smart Switch additional power management flexibility not found in any other transfer switch.Not compatible with pre-wired switches.Note:PMM Starter Kit required. Generac's Mobile Link device allows you to check the status of your generator from anywhere that you 006463-0 Mobile Link"Device have access to an Internet connection from a PC or with any smart device.You will even be notified when a change in the generator's status occurs via e-mail or text message. *Note:Bisque kits are used in conjunction with steel enclosures.Gray kits are used in conjunction with aluminum enclosures. dimensions Dimensions shown are approximate. Contact your Generac dealer for certified drawings. DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES. 637.6 mm [25.1 in.] 127. mm [47.9 in.] O 731.9 mm [28.8 in.] GENERAC' -- — 110 — — — O 642 mm ___.._ -- [25.3 in.] - 76.2 mm[3.0 in 1 1226 mm PEA GRAVEL - ------_--_--[48.3 in.]—- MINIMUM LEFT SIDE VIEW FRONT VIEW GENERAC Generac Power Systems,Inc. • S45 W29290 HWY.59, Waukesha,WI 53189 • generac.com &-2013 Generac Power Systems,Inc. All rights reserved. All specifications are subject to change without notice. Bulletin 0197990SBY-F Printed in U.S.A.05/29/13