Loading...
HomeMy WebLinkAbout38145-Z �. Town of Southold Annex 5/2/2014 P.O.Box 1179 54375 Main Road Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 36889 Date: 5/2/2014 THIS CERTIFIES that the building WIRELESS COMMUNICATION SYSTEMS Location of Property: Oriental Ave, Fishers Island, SCTM#: 473889 Sec/Block/Lot: 9.-7-11.1 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this officed dated 7/1/2013 pursuant to which Building Permit No. 38145 dated 7/1/2013 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: modifications to an existing;wireless telecommunication facility as qpplied for. The certificate is issued to Our Lady of Grace RC Ch (OWNER) of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. PLUMBERS CERTIFICATION DATED A h Sign re TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE V SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 38145 Date: 7/1/2013 Permission is hereby granted to: Our Lady of Grace RC Ch PO BOX 425 Fishers Island, NY 06390 To: construct modifications to an existing wireless telecommunication facilit y per Planning Board as applied for At premises located at: Oriental Ave SCTM # 473889 Sec/Block/Lot# 9.-7-11.1 Pursuant to application dated 7/1/2013 and approved by the Building Inspector. To expire on 12/31/2014. Fees: WIRELESS COMMUNICATIONS -MODIFICATIONS $500.00 CO -COMMERCIAL $50.00 Total: $550.00 t Building Inspector Fern No,b TOWN OF SOUTHOLD BU111 IAlO DkPARTMM TOW BALL' APPUCATION FOR CZRTMCATS OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use; 1. Final sus" e' of property with accurate location of all buildings,Property lines,streets,and unusual natural or topogtupheo Mures.'' 2. Final ppro al from,Health Dept.,of water supply and scxvarage-disposal(8-9 form). 3. Appio of+ octricel installation from Board of Fixe Ondetwriters. 4. Sworn statement from plumber certifying that the solder used in system contains leas titan 2/10 of 1%IN& 5. Commercial building,industrial building,multiple rroidences and similar buildings and installations,a Certificate of Code Compliance:fiom architect or engineer responsible for the building. 6: Submit Planning Board Approval of completed site plan requirements. B. For existing buildings(prior to April 9,1957)'non-conforming uses,or buildings and"prs-esisti eumt uses: 1 Amite survey-of property showing all property lines,streets,building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant.If a Certificate ate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1 Certificate of Occupancy-New dwelling$25.00,Additions to dwelling$25.00,Alterations to dwelling$25.00, Swimming pool$25.00,Accessory building$25.00,Additions to accessory building$25.00,Businesses$50.00. 2 Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate Of Occupancy-$.25" 4 Updated Certificate of Occupancy- $50.00 5, Temporary Certificate of Occupancy-Residential$15.00,Commercial$15.00 Bate. *UpgradelModificatiou to existing public utility wireless telecommunications facility New Construction: X* ` Old or Pre-existing Building: (check one) Location of Property: 9245 Main Road East Marion House No. Street Hamlet Owner or Owners of Property: Bast Marion Fire District Suffolk County Tact Map No 1000,Section 31 Block' 3 Lot 11.31 Subdivision Filed Map. Lot: Permit No. Date of Permit. Applicant: New Cingular Wireless PCS,LLC("AT&T") Health Dept.Approval: Underwriters Approval: Planning Board Approval:- N/A Request for: Temporary Certificate Final Certificate: (check one) Fee Submitted:$ ' 50.00 Ne Wgular Wire CS,L C Bar Applicant Signature Doug Hail,President of Shore 2 Shore Wireless,Inc., Agent for Applicant • r r r r •r: r INSULATION PEk N.Y. STATE MMGY COODE Pill OWN I� ADDMONAL COMNMNTS MIN WIMP-PIN-111 F,NINMA Y O M ` i' TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD,NY 11971 4 sets of Building Plans TEL: (631)765-1802 Planning Board approval FAX: (631)765-9502 Survey SoutholdTown.Norffork.net. PERNIIT NO. Check Septic Form N.Y.S.D.E.C. DFlood Permit Examined Q 2Q Storm-Water Assessment Form R MAY 2 1 2013 ontact: Attorney for Applicant: . Approved 61 , ,20 Mail to: Re,Nielsen,Huber&Coughlin,LLP Disapproved a/c l) BLDG.DEPT. 36 N.New York Ave.,Huntington,NY 11743 — TOWN OF SOUTHOLD Phone: 631425-4100 Expiration ,20� Butldmg Inspector APPLICATION FOR BUILDING PEI RNUT Date ,20 INSTRUCTIONS a.This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans,accurate plot plan to scale.Fee according to schedule. b.Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas,and waterways. c.The work covered by this application may not be commenced before issuance of Building Permit. d.Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant.Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f.Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date.If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize,in writing,the extension of the permit for an addition six months.Thereafter,a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk County,New York,and other applicable Laws,Ordinances or Regulations,for the construction of buildings,additions,or alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code,housing code,and regulations,and to admit authorized inspectors on premises and in building for necessary inspections. New Cingular Wireless PCS,LLC (Signature of applicant or name,if a*cV gV * Limited Liability company 1444 E.Jericho Tpke.,Huntington,NY 11743 (Mailing address of applicant) State whether applicant is owner, lessee, agent,architect,engineer,general contractor, electrician,plumber or builder Applicant is Lessee I r (�- ��e+• - Name of owner of premises OJ f L—k D"� �`(c�C e M pp limited liability.com any (As on the tax roll or latest deed) If applicant is signature of duly authorized officer (Namea i Doug Hall,President of Shore 2 Sbore Wireless,Inc.,Agent for Applicant Builders License No. Plumbers,License No. N/A Electricians License No. Other Trade's License No. 1. Location of land on which proposed work will be done: Our Lady of Grace Church Oriental Avenue Fishers Island House Number Street Hamlet County Tax Map No. 1000 Section 9 Block 7 Lot . Map ` r�� Subdivision , Filed Ma No. ,� ' .. Lot 1 e 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy Religious Use and Public utility wireless telecommunications facility b. Intended use and occupancy Same as existing 3. Nature of work(check which applicable):New Building Addition Alteration Repair Removal Demolition Other Work Lessee/Applicant propose to modify/upgrade its exising public utility wireless telecommunications facility as depicted in the plans submitted herewith. (Description) 4. Estimated Cost o�`J � 9 Fee (To be paid on filing this application) 5. If dwelling,number of dwelling units N/A Number'.o flidgel) ttnits on each floor If garage, number of cars 'Religious Use and Public utility wireless telecommunications 6. If business,commercial or mixed occupancy,specify nature and extent of each type of usefacility 7. Dimensions of existing structures,if any:Front Rear Depth Height Number of Stories Dimensions of same structure with alterations or additions: Front Rear Depth Height Number of Stories *No change S. Dimensions of entire new construction:Front Rear Depth Height Number of Stories 9. Size of lot: Front Rear Depth 10.Date of Purchase Name of Former Owner 11.Zone or use district in which premises are situated R-80 12.Does proposed construction violate any zoning law,ordinance or regulation?YES NO X 13. Will lot be re-graded? YES NO X Will excess fill be removed from premises?YES ' NO .'X 14.Names of Owner.of premises ddress �.srs 2s M•'I Phone No.9\OU- �2 Name of Architecclietwel I Address XAj o k Phone Nos�o-S-11 Address Phone No l I - O� Name of Contractor a� \ axf 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? * S NO *IF YES, SOUTHOLD TOWN TRUSTEES&D.E.C.PERMITS MAYBE REQUIRED. b. Is this property.within 300 feet of a tidal wetland?*YES NO * IF YES,D.E.C.PERMITS MAY BE REQUIRED. 16.Provide survey,to scale,with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below,must provide topographical data on survey. 18.Are there any covenants and restrictions with respect to this property? *YES NO * IF YES,PROVIDE A COPY- STATE OF NEW YORK) SS: COUNTY OF_�G Doug Hall _ being dilly sworn,deposes and says that(s)he is the%RRUMk (Name of individual signing contract)above named, miff M President of Shore 2 Shore Wireless,Inc.,Agent for Applicant-New Cingular Wireless PCS LLC Lessee (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application; that al l statements contained in this application are true to the best of his knowledge and belief;and that the work will be performed in the manner set forth in the application filed therewith. Sworn to befoMtPublic 20 L�! New ar Wireless S,LLC Ne aL 13y: 4 sign a of Applicant Victoria Brennan, Esq Doug Hall President of Shore 2 Shore Wireless Inc.,Agent for Applicant Notary Public,State of New York Print Name/Title above No. 02BR6072822 Qualified in Nassau County Commission expires April 15, 201 r' FOR INTERNAL USE ONLY I` TI SITE PLAN USE DETERI11#NAON initial Determination • Date Sent:=_f. !-1= -�-- project—Name:-0/ project Address: . .- - Zoning District-AL -_._.--- . Suffolk County Tax Map No..1.egg ___-1-__—�- Request: (Note: Copy of Building Permit Application and supporting documentation,a&to proposed use or uses should be submitted.) D �( I initial Determination as to whether use is permitted: P-- S Initial Determination as to whether site plan is required: Planning Board Signature of Building In Planning Department(P.D.) Referral: ? I l P.D. Date Received: S� Date of Comment__ _i — M � ts: - om . .a Signature of planning Dept. Sta viewer Final Det�rrttina on Date: � Decision: MAILING ADDRESS: PLANNING DO ALD BOARD MEMBERS ry0 SouthOold,oNY 171 QF sou Chair OFFICE LOCATION: WILLIAM J.CREMERS Town Hall Annex PIERCE RAFFERTY G 54375 State Route 25 JAMES H.RICH III • �O (cor.Main Rd. &Youngs Ave.) MARTIN H.SIDOR CAUtM,�c� Southold,NY Telephone: 631 765-1938 Fax: 631 765-3136 PLANNING BOARD OFFICE TOWN OF SOUTHOLD MEMORANDUM To: Michael J. Verity, Chief Building Inspector From: Heather M. Lanza,AICP, Planning Director Date: June 27,2013 Re: Planning Department Report AT&T Mobility LTE Modifications and Up-grades SCTM#1000-9-7-11.1 Oriental Avenue and Ettrick Avenue, Fishers Island As an addendum to the attached SPUD,the Planning Department has conducted a review of the proposed LTE modifications pursuant to §280-74 B.(2), and has received a report from our Wireless Technical Consultant, Cityscape, Inc. (see attached report). We have the following recommendations for this application: 1. The proposed LTE modifications and upgrades are in compliance with the General Requirements of§280-70, therefore, we recommend a Building Permit be issued for this application consistent with the project drawings dated April 23, 2013. Thank you for your cooperation. State of New York ° a ® e Telecommunications Site Review Consultants, Inc. Concealed Facility Upgrade 7050 W.Palmetto Park Road#15-652 Boca Raton,Florida 33433 Tel:877-438-2851 Fax:877-220-4593 June 14, 2013 Heather M. Lanza.,AICP Planning Director Town Hall Annex Building 53095 Route 25 JUN 19 2013 Southold,New York 11971 RE: Carrier: AT&T Mobility: NYNYNY0801 SCTM : 1000-9-7-11.1 Address: Oriental Avenue at Ettrick Avenue Dear Ms. Lanza, At your request on behalf of The Town of Southold in New York, CityScape Consultants, in its capacity as telecommunications consultant for the Town, has considered the merits of an application provided by AT&T Mobility ("Applicant") to make antennas and electronic equipment modifications to a facility located inside an existing Church Steeple. The AT&T antennas have a total elevation of thirty-eight(38) feet. The total elevation of the steeple with the top mounted cross is sixty-six feet one inch (66' 1"), see figure 1. AT&T Mobility plans to add new equipment cabinets in the current leased space located in the Church basement, see figure 2. The purpose is for AT&T Mobility to provide new high speed wireless broadband service to complement their existing cell phone service on Fisher Island in the jurisdiction of the Town of Southold. The location is Our Lady of Grace Church and is physically located at Oriental and Ettrick Avenues in the Town of Southold jurisdiction see figure 3. AT&T Mobility is in the process of upgrading their existing services by modifying their antenna and related equipment at all their sites throughout the United States. This application is one of many similar type proposed changes intended to provide new fourth generation (4G) LTE service into the general area. LTE is the Applicant's version of fourth generation technical service. LTE means long term evolution or candidly the service will require an unknown amount of time prior to substantially provide very high speed data transference. The LTE technology is for high speed wireless broadband implementation. The final configuration will consist of three (3) panel type antennas and six (6) new Remote Radio Head (RRH) units, a Raycap DC surge protection system and a microwave dish antenna for backhaul data transfer all located at generally the thirty-five (3 5)foot elevation level see figure 4. The antenna sections,remote radio heads and Raycap equipment vary in elevation to fit within the general area and the difference is not something that would impact the Town's application process. Interconnecting the ground equipment and the related antenna propagation equipment will be a combination of feed lines and fiber optics cable. AT&T Mobility:NYNYNY0228 SCTM: 1000-108-4-11.3 o G Address:415 Elijah Lane Southold,New York Consultants, Inc. June 14,2013 Telecommunications Site Review Page 2 New York Concealed Facility Upgrade In this particular situation the changes being made for AT&T Mobility is within a Church steeple and will not cause an overload concern; although the applicant did submit a structural analysis. Likely because that has been the past practice but in this situation it was not necessary since the equipment is not exposed and does not have a windload impact. The only potential structural consideration would be the deadweight of the changes which is minimal, see figure 5. The Applicant supplied calculations to assure compliance with all FCC standards regarding human exposure to Radio Frequency energy. The Applicant's spectrum will operate in both the 850MHz range and the 1,900MHz range but should not be an interference concern to the Town's public safety communications. The Applicant is required to state they will comply with federal interference rules and the federal rules regarding human exposure to radio frequency energy. That was not initially submitted but when requested was promptly provided, see figure 6. All designs and plans for the proposed new facilities were developed according to accepted practices of RF propagation engineering and the persons completing all work are sufficiently qualified within their disciplines. Therefore CityScape as wireless expert for the Town of Southold recommends this application be approved as submitted and including the supplemental information. Respectfully submitted, R { Richard L. Edwards FCC Licensed PCIA Certified Cityscape Consultants, Inc. i AT&T Mobility : NYNYNY0228 M M SCTM : 1000-108-4-11.3 21-1 i Address.415 Elijah Lane Southold,New York Consultants, Inc. June 14,2013 Telecommunications Site Review Page 3 New York Concealed Facility Upgrade r- INSTALL (1) RAYCAP Dc6 DOME ON PIPE TOP OF CROSS_ (SEE DETAIL i/AO4 * 1102/A06) FOR MOUNTING (SEE DETAIL 1 116/A06) SWAP (t) AT&T ANTENNA FOR NEW QUINTEL AT&T ANTENNA (SECTOR A) INSTALL (2) PROPOSED RRH'S All Antenna (SEE DETAIL 2&3/AO3) MOUNTED ON UNISTRUT MAST (SECTOR B) INSTALL (2) PROPOSED RRH'S MOUNTED (SEE DETAIL 2/AO4) ON UNISTRUT WITH PROPOSED PIPE MAST ss and related (SECTOR A) (SEE DETAIL 1/A04) i SWAP (1} AT&T ANTENNA FOR NEW QUINTEL AT&T ANTENNA (SECTORS B) INSTALL (2) PROPOSED RRH'S MOUNTED--_1 j { (SEE DETAIL 2&3/AO3 do 2/A04) equipment i s ON UNISTRUT WITH PROPOSED PIPE MAST OPENINGS AND CONCEALMENT TO BE (SECTOR C) (SEE DETAIL 2/AO4) REWORKED AS NECESSARY FOR 1 PROPOSED ANTENNAS (ALL SECTORS) SWAP (i) AT&T ANTENNA FOR NEW concealed and � / (SEE QUINTEL ATT AIdt2&Ate Oft3)A (SECTOR C) will not be $TOP OF LTE AT&T ANTENNA visible from 38'-0' t A.G.L. l `'YP. ALL SECTORS' pedestrian view BRAD. CENTER OF LTE AT&T ANTENNA 35'-0' t A.G.L. (TYP. ALL SECTORS) FLOOR OF UPPER STEEPLE 1 30`-1Tt A.G.LA.G.L —� t i 1 1 1 OF LOWER STEEP 1 18—7 t A.G.L 1 PROPOSED POWER AND FIBER — I CABLES ALONG EXISTING ROUTE IN 2I4* INNERDUCT 1 �TQ�QUIP. ROOM CLG� T _ 1'-711 A.G.L EXISTING GRADE 0'-0't -EXISTING AT&T EQUIPMENT ROOM IN BASEMENT T IP. M F.F.E 4 0 4 8 12 Ff Figure 1. Church Steeple Elevation SCT Mobility:N4-11.3 228 SCTM: 1000-108-4-11.3 a O Address:415 Elijah Lane Southold,New York Consultants, Inc. June 14,2013 Telecommunications Site Review Page 4 New York Concealed Facility Upgrade ram' *u Ae Ac is --—y "dale UCW 4 1tw N � CARNET 00STIIAa PJ�f1A W M \ t �� 1El1CQ BOO ti 24V DC \\ F7UNO Ii�H iF BN p11:K PC0 '2�V ' ooc Sr 0 1. ! T R Figure 2. Ground Equipment in Basement AT&T Mobility:NYNYNY0228 n ■ ■■■■■■■■■ SCTM : 1000-108-4-11.3 W G Idik Address:415 Elijah Lane Consultants Inc. Southold,New York June 14,2013 Telecommunications Site Review Page 5 New York Concealed Facility Upgrade DeLorme Street Atlas U SAO 2009 D CeWkAL A I z F5 i j �pYa C+oDStItlW O P WEST 57 JF' llP e e` e� P'iJ' v G �y J .Q , 7(na6 4t'OW O Dc T S 0% in 9�q 2 W �I THE L T EAST END RD 'At R4ap n Data use subject to license. } ft ®DeLorme Del-orme Street Atlas USAO 2009. 0 180 360 540 720 900 www delorme corn MN(14.1°W) Data Zoom 15-0 Figure 3. Site Location AT&T Mobility:NYNYNY0228 SCTM : 1000-108-4-11.3 o G Address:415 Elijah Lane — Southold,New York Consultants, Inc. June 14,2013 Telecommunications Site Review Page 6 New York Concealed Facility Upgrade —LINE OF EXISTING INSTALL (2) PROPOSED RRH'S MOUNTED GABLE jggE BELOW ON UNISTRUT WITH PROPOSED PIPE ,EXISTING LAND LINK PARABOLIC ANTENNA (SECTOR A) (SEE DETAIL 1/AO4) \ / SWAP (1) AT&T ANTENNA FOR NEW QUINTEL AT&T ANTENNA (SECTOR A) � (SEE DETAIL 2&3/AO3) INSTALL (2) PROPOSED RRH'S - MOUNTED ON UNISTRUT WITH \ I INSTALL (1) RAYCAP DC6 DOME ON PIPE PROPOSED PIPE MAST (SECTOR C) \ / II (SEE DETAIL 1/AO4 & 1102/ADS) FOR (SEE DETAIL 2/AD4) \/ II MOUNTING (SEE DETAIL 1116/A06) I I SWAP (1) AT&T ANTENNA FOR NEW /' _ J� \ INSTALL (2) PROPOSED RRH'S MOUNTED QUINTEL AT&T ANTENNA (SECTOR C) — ON UNISTRUT WITH PROPOSED PIPE MAST (SEE DETAIL 2&3/AO3) / \5ECTOR_*T (SECTOR B) (SEE DETAIL 2/AO4) / a�Q SWAP (1) AT&T ANTENNA FOR NEW u N QUINTEL AT&T ANTENNA (SECTOR B) (SEE DETAIL 2&3/AO3) 2' 0 2 4 5 Fr Figure 4. Final Antenna Configuration AT&T Mobility:NYNYNY0228 ■ ■■ ■ SCTM: 1000-108-4-11.3 Address:415 Elijah Lane Consultants, Inc. Southold,New York June 14,2013 Telecommunications Site Review Page 7 New York Concealed Facility Upgrade j. loo Paragm Drive MoMvaie,NJ 07645 Td: (2011571-0650 Fax: (20115710763 May 2,2013 Mr.Joseph Sweet New Cingular wireless PCS,LLC("AT&T~) 340 Mt.Kemble Avenue Morristown,NJ 07960 Subject: Structural Analysis Report AT&T Site 100: NYNYNY0601 AT&T USI DM: 357118 AT&T Site Name: FISHERS ISLAND 5 OVERLAY Oriental Ave and Ettrick Ave„Fishers island,NY 06390 Laititude:N 410 15'38.7(r;Longitude:W 72°00'51.99" Dear Mr.Sweet. Bechtel Associates Professional Corporation Is pleased to submit this"Structural Analysis Report-to determine the structural integrity of the existing antenna support structures at the above mentioned telecommunication facility. The site was visually Inspected during a site visit occurring on December 6,2012. The steeple interior members,the connections of the masts,and the building itself were found to be in good visual condition. Destructive testinglinvestigation methods were not employed during the Inspection. The existing,AT&T equipment is mounted on the inside of the steeple in for all sectors The proposed scope or work consists of swapping(1)antenna in each sector,as well as the addition of(61 remote radio heads added in the steeple. The e,dsting and proposed mounting hardware has been analyzed to handle the existing and proposed loadings. The existing mounts have the structural capacity to support the proposed coofiguration as shown in the constnution drawings, 0000i Bond on our analysis,we ban doter.. that the oidstkV mourns are structurally adequate to proceed with proposed work in accordance with the regtdremerits of the 9uildna Code of the State of New York— 2010 and TIA/EIA-222-F(199`6}, Respectfully submitted by: �s 5O 4r, Z i t Ap _ 4• Richard M.Coad,P.E. 'epaS4 .j a�+F NY license WX5434.1 � dBtdNAV�� Bechtel Associates Professional Corporation Figure 5. Structural Analysis AT&T Mobility:NYNYNY0228 SCTM : 1000-108-4-11.3 Address:415 Elijah Lane Consultants, Inc. Southold,New York June 14,2013 Telecommunications Site Review Page 8 New York Concealed Facility Upgrade aw To Town of SoAmhl fts firbsf Kah"4 n PeolarrwnrkRAN&gnw►.Now Ci, vW W Wm PCS,u c CAT n solis W17/2t113 no PmpoaW to modify Woomwowicokm Y W Ow tacyof Gnroe Chin. Orw W Avow^Fir' War4 W(WW) To Who"t1 May Cohn This OW mw io eaftn ihrt the f"mancim#W wIN to and by Now GinWW WWW" PCS,u.0 CAT&T').(TmwM INS 19M MHz.880,880 MHz,SW-8014 MHz.740-746 MHz, PWOW 189 IM MHz. 824 4M MHz, SW 64" W4Z. 710-716 MHZ) h oornnrdlon WM N0-mi 4ms Mf BOWWinuni Mikim in"WAlk n at 8M*"V*-o4POxW 0-I eidaa &W 0-r modilhod will nol i4a d*rb or dw**b any► amw9wicr cares rdaalsn Mme.o►'" lip, W o radio.bOavi ion D ookft WNih"sysmi a KVW nooapNkrn of simir rgnW4 for nearby 1 ;, 11- in I*owl 00 AT&T's equipment dory 6aurs msowmW irntr hN pious to any of MM psft"mrr*wW soviet AT&T ofW up dllprrM Minh b n anrsdlrlr such radssros. AT&T we oompty 110 al FCSC nilas wlgacong frnanrn WOMw to radio AnagiMni V OWW. AT&T wd own*nrn al FCC nntrs ngm A Isstwnoa b cols ado sw4wn, Tlwn*you. SWO10*1 P"t�M►� P40 Kohimem Prdoolowl RAN E+nghm Figure 6. FCC Compliance Statements RF Exposure Analysis for New Cingular Wireless PCS LLC Antenna Facility Site ID: NYNYNY0801 November 27`h, 2012 Prepared by Bernard Morgan Senior RF Engineers - ----•___,.., Bechtel Communications, Inc. i New Cingular Wireless PCS,LLC Table of Contents 1. INTRODUCTION................................................................................................................................3 2. SITE DATA...........................................................................................................................................3 3. FCC GUIDELINES FOR EVALUATING THE ENVIRONMENTAL EFFECTS OF RF RADIATION.....................................................................4 4. COMPARISON WITH STANDARDS AT 6FT ABOVE GROUND..............................................5 5. CONCLUSION AT 6FT ABOVE GROUND.....................................................................................5 6. FCC LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE PER FREQUENCY...................6 7. EXHIBIT A—INDIVIDUAL SYSTEMS POWER DENSITY BY DISTANCE AT 6FT ABOVE GROUND....................................................................7 8. FOR FURTHER INFORMATION.....................................................................................................9 9. REFERENCES.....................................................................................................................................9 2 I I New Cingular Wireless PCS,LLC 1. Introduction This report constitutes an RF exposure analysis for the New Cingular Wireless PCS LLC("AT&T")antenna facility to be located at Oriental Avenue and Ettrick Avenue, FISHERS ISLAND, NY 06390 This analysis uses site- specific engineering data to determine the predicted levels of radio frequency (RF) electromagnetic energy in the vicinity of the facility and compares those levels with the Maximum Permissible Exposure (MPE) limits established by the Federal Communications Commission. 2. Site Data AT&T Site Name: NYNYNY0801 Number of simultaneously operating channels GSM850:4-4-4 GSM1900:4-4-4 UMTS 1900:2-2-2 UMTS850:2-2-2 LTE700:1-1-1 Type of antenna Ouintel S6658-2 for GSM/UMTS/LTE Power per channel(Watts ERP) GSM850:316 Watts GSM1900:600 Watts UMTS850:316 Watts UMTS1900:600 Watts LTE700:524 Watts Center line of Antenna feet AGL 35'4" Antenna Aperture Length 4'3" 3 I I New Cingular Wireless PCS,LLC RF Exposure Prediction The following equation established by the FCC,in conjunction with the site data,was used to determine the levels of RF electromagnetic energy present in the vicinity of the facility: 0.64*N*EIRP(0) PowerDensity = 7r*R2 (mw/cm2) Eq. 1-Far field Where,N=Number of channels,R=distance in cm from the RC(Radiation Center)of antenna,and EIRP(Q)—The isotropic power expressed in milliwatts in the direction of prediction point. 3. FCC Guidelines for Evaluating the Environmental Effects of RF Radiation In 1985,the FCC established rules to regulate radio frequency(RF)exposure from FCC licensed antenna facilities. In 1996,the FCC updated these rules,which were further amended in August 1997 by a Second Memorandum Opinion and Order. These new rules represent a consensus of the federal agencies responsible for the protection of public health and the environment, including the Environmental Protection Agency (EPA), the Food and Drug Administration (FDA), the National Institute for Occupational Health and Safety (NIOSH), and the Occupational Safety and Health Administration(OSHA). Under the laws that govern the delivery of wireless communications services in the United States,as amended by the Telecommunications Act of 1996, the FCC has exclusive jurisdiction over RF emissions from personal wireless antenna facilities,which include cellular,PCS,messaging and aviation sites.2 Pursuant to its authority under federal law,the FCC has established rules to regulate the safety of emissions from these facilities. I RF exposure is measured and predicted in terms of power density in units of milliwatts(mW),a thousandth of a watt,or microwatts(p W),a millionth of a watt,per square centimeter(cm2). Data comparing predictive analysis with on site measurements has demonstrated that power density can be effectively predicted at given locations in the vicinity of a wireless antenna facility. 2 47 U.S.C.Section 332(c)(7)(Bxiv)states that"[n]o State or local government or instrumentality thereof may regulate the placement,construction,and modification of personal wireless service facilities on the basis of the environmental effects of radio frequency emissions to the extent that such facilities comply with the Commission's regulations concerning such emissions." 4 i New Cingular Wireless PCS,LLC 4. Comparison with Standards at 6ft above ground The maximum cumulative power density at the upgraded facility represents 3.42%of the public/uncontrolled MPE limit.This is at 6 feet above ground and approximately 32 feet from the antenna facility. Urcortrolled MPE Result W ck- 2 .a n C O U C G'S Horizontal Distance From Antenna.ft 5. Conclusion at 6ft above ground This analysis requires a conservative methodology and is based on the simultaneous and continuous operation of all transmitters. In actual operation, many of the transmitters will operate intermittently and therefore the actual levels will be even lower. This analysis shows that the maximum power density in accessible areas at this location is well below the Maximum Permissible Exposure limit established by the FCC. Other operators' antenna locations have been included in the study to give a composite value. 5 New Cingular Wireless PCS,LLC 6. FCC Limits for Maximum Permissible Exposure per Frequency FCC limits for Maximum Permissible Exposure (MPE) Plane-wave Equivalent Power Density 9,000 --- Occupadonal/Contr fled Exposure General Populatlon/Uncontrolled Expose 100 E \ � 10 \ \ laic 4eoaMrkm2 C..Ldw:M awkm2 0.2 - - - - -.i 0.1 0.03 0.3 3 30 300 3,000 30,000 ¢300,000 1.34 1.500 100,,000 Frequency (MHz) 6 New Cingular Wireless PCS,LLC 7. Exhibit A—individual systems power density by distance at 6ft above ground ATAT ON faadar band 4 k 1000 Y � 100 r Y to Z• Fp 1 d q O } 0.01 0.1 1 10 100 7000 10000 Horizontal Distance from Antenna at6 t above raand,It 10000 AUTGOIRCfiaaad .. .� � C f 1000 my Al 10 , 1 " y n 01 r 001 0.1 1 10 100 1000 10000 HarmorxaalDstarl00aaal Aahma at6ftabm ft Tu AT Petted 10000 � a 39 100 a 1c .. d " � 01 4 Yr x� 001 0.1 1 10 loo 1000 10000 Hanw"Name fm AmMmalft&bow pl S4,ft 7 New Cingular Wireless PCS,LLC tA600 y x y : � 3 1060 TM 1 100 1 i Z �• QAt ,,ac ca :ae At 1 i0 100 1600 i0000 Haiam�D tw"famkteea± *5habm FNW,ft AT&T ITEM Md 16000 3K Y '#§' k ��§ v t06D y im r @ 3 a C L Oa t —skids, a� OAt 01 HO D'stmmfsmt said .. 10606 .ft 8 New Cingular Wireless PCS,LLC 8. For Further Information Additional information about the environmental impact of RF energy from personal wireless antenna facilities can be obtained from the Federal Communications Commission: Dr.Robert Cleveland Federal Communications Commission Office of Engineering and Technology Washington,DC 20554 RF Safety Program: 202418-2464 Internet address: rfsafety@fcc.gov RF Safety Web Site: www.fcc.gov/oet/rfsafety 9. References [1] The Communications Act of 1934,as amended by the Telecommunications Act of 1996,47 U.S.C.Section 332(c)(7)(Bxiv). [2] Guidelines for Evaluating the Environmental Effects of Radio frequency Radiation,Notice of Proposed Rulemakine,ET Docket 93-62,8 FCC Rcd 2849(1993). [3] Guidelines for Evaluating the Environmental Effects of Radioftequency Radiation,Revort and Order,ET Docket 93-62,FCC 96-326,adopted August 1, 1996.61 Federal Register 41006(1996). [41 Guidelines for Evaluating the Environmental Effects of Radioftequency Radiation,Second Memorandum OQpinion and Order,ET Docket 93-62,adopted August 25, 1997. [5] Evaluating Compliance with FCC Guidelines for Human Exposure to Radio frequency Electromagnetic Fields,OET Bulletin 65,August, 1997. 9 ti United States Code [� United States Code (3 TITLE 47—TELEGRAPHS.TELEPHONES.AND RADIOTELEGRAPHS CHAPTER 13—PUBLIC SAFETY COMMUNICATIONS AND ELECTROMAGNETIC SPECTRUM AUCTIONS [� SUBCHAPTER IV—SPECTRUM AUCTION AUTHORITY 47 U.S.C. § 1455. Wireless facilities deployment (a) Facility modifications (1) In general — Notwithstanding section 704 of the Telecommunications Act of 1996 (Public Law 104-104) or any other provision of law, a State or local government may not deny, and shall approve, any eligible facilities request for a modification of an existing wireless tower or base station that does not substantially change the physical dimensions of such tower or base station. (2) Eligible facilities request — For purposes of this subsection, the term "eligible facilities request" means any request for modification of an existing wireless tower or base station that involves — (A) collocation of new transmission equipment; (B) removal of transmission equipment; or (C) replacement of transmission equipment. (3) Applicability of environmental laws — Nothing in paragraph (1) shall be construed to relieve the Commission from the requirements of the National Historic Preservation Act 116 U.S.C.470 et seq.] or the National Environmental Policy Act of 1969 [42 U.S.C.4321 et seq.] (b) Federal easements and rights-of-way (1) Grant — If an executive agency, a State, a political subdivision or agency of a State, or a person, firm, or organization applies for the grant of an easement or right-of-way to, in, over, or on a building or other property owned by the Federal Government for the right to install, construct, and maintain wireless service antenna structures and equipment and backhaul transmission equipment, the executive agency having control of the building or other property may grant to the applicant, on behalf of the Federal Government, an easement or right-of-way to perform such installation, construction, and maintenance. (2) Application — The Administrator of General Services shall develop a common form for applications for easements and rights-of- way under paragraph (1) for all executive agencies that shall be used by applicants with respect to the buildings or other property of each such agency. (3) Fee (A) In general — Notwithstanding any other provision of law, the Administrator of General Services shall establish a fee for the grant of an easement or right-of-way pursuant to paragraph (1) that is based on direct cost recovery. (B) Exceptions — The Administrator of General Services may establish exceptions to the fee amount required under subparagraph (A)- (i) in consideration of the public benefit provided by a grant of an easement or right-of-way; and (ii) in the interest of expanding wireless and broadband coverage. (4) Use of fees collected — Any fee amounts collected by an executive agency pursuant to paragraph (3) may be made available, as provided in appropriations Acts, to such agency to cover the costs of granting the f easement or right-of-way. (c) Master contracts for wireless facility sitings (1) In general — Notwithstanding section 704 of the Telecommunications Act of 1996 or any other provision of law, and not later than 60 days after February 22, 2012, the Administrator of General Services shall — (A) develop 1 or more master contracts that shall govern the placement of wireless service antenna structures on buildings and other property owned by the Federal Government; and (B) in developing the master contract or contracts, standardize the treatment of the placement of wireless service antenna structures on building rooftops or facades, the placement of wireless service antenna equipment on rooftops or inside buildings, the technology used in connection with wireless service antenna structures or equipment placed on Federal buildings and other property, and any other key issues the Administrator of General Services considers appropriate. (2) Applicability — The master contract or contracts developed by the Administrator of General Services under paragraph (1) shall apply to all publicly accessible buildings and other property owned by the Federal Government, unless the Administrator of General Services decides that issues with respect to the siting of a wireless service antenna structure on a specific building or other property warrant nonstandard treatment of such building or other property. (3) Application — The Administrator of General Services shall develop a common form or set of forms for wireless service antenna structure siting applications under this subsection for all executive agencies that shall be used by applicants with respect to the buildings and other property of each such agency. (d) Executive agency defined — In this section, the term "executive agency" has the meaning given such term in section 102 of title 40. ( Pub.L. 112-96, title VI, Sec. 6409, Feb. 22, 2012, 126 Stat. 232. ) REFERENCES IN TEXT Section 704 of the Telecommunications Act of 1996, referred to in subsecs. (a) (1) and (c) (1), is section 704 of Pub.L. 104-104, which amended section 332 of this title and enacted a provision set out as a note under section 332 of this title. The National Historic Preservation Act, referred to in subsec. (a) (3), is Pub.L. 89-665, Oct. 15, 1966, 80 Stat. 915, which is classified generally to subchapter II (Sec. 470 et seq.) of chapter lA of Title 16, Conservation. For complete classification of this Act to the Code, see section 470(a) of this title and Tables. The National Environmental Policy Act of 1969, referred to in subsec. (a) (3), is Pub.L. 91-190, Jan. 1, 1970, 83 Stat. 852, which is classified generally to chapter 55 (Sec. 4321 et seq.) of Title 42, The Public Health and Welfare. For complete classification of this Act to the Code, see Short Title note set out under section 4321 of Title 42 and Tables. Copyright®2012 CCH Incorporated or its affiliates TOWN OF SOUTHOLD COUNTY OF SUFFOLK: STATE OF NEW YORK ------I--------------------------------------------------------------------------------X In the Matter of the Application of New Cingular Wireless JPCS,LLC AUTHORIZATION OF OWNER At the premises("Premises") Our Lady of Grace Church Oriental Avenue Fishers Island,New York Section 9,Block 7,Lot 11.1 .-----------------------------------------------_ ----------------------+----------X STATE OF NEW YORK ) ' SS.. COUNTY OF SUFFOLK ) '7e..v..,..... a�_k.._�._._.�.� ►.4,1� being dry(} sworn,deposes and says: of the lt�[I a Ce owner m fee of the premises I am the.... caS-F-0`r....._.._._.. ......_ _ove— .� __ known as District 1000,Section 9,Block 7,Lot 11.1 (the 1'1°onuses"hereafter),and do hereby authorize New Cingular Wireless PCS, LLC ("AT&T" hereafter), and its representatives to bring such applications for municipal approvals as may be necessary for the uh,,r�j(Ie/njociiticati0 n of its public utility wireless telecommunications facility. As such, I will fully cooperate with AT&T and its agents in obtaining any required Approvals. Sworn to before me this day of Ala X ,201; NOTAY PUBLIC NANCY M. POTTER NOTARY PUBLIC W COMMISSION EXPIRES DEC.$1,2015 GCB COTY This to not ao*rout ACC hoses,it is a reoard ofpuUc faMmakloo oon4Eoed in die FCC's liomeing ddslisse on to dots diet this rdasooe copy was gswaOecL to seine when FCC rules require the leamWdoo,posft or display of ao ACC lioean this dawooe may not be used In plea of a<OM*l FCC license. Federal Communications Comm talon 7A E, } L� Wt1°do�g Telecommn�doni B11Pt'ltltl �.: RADIO STATION AUTHORIZATION UC8NSIM: AT&T MOB(EM n LW CAB 1111P lilt Number ATTN:FCC GROUP,- Y WPWU948 AT&T MOBILITY D LLC ,.,f Radio Bervlos 5601 LEGACY DRIVI3,MS;A4, WZ-700 M&Lower Bend(Bloch C, PLANO,TX 75024 D) FCC Raglstradoo Number(FRl)t 0016982133 .' Grant Date BAleatlee Dine <; Xxpkxdao Date PMnt Date 01-24-2003 03-16.3010 06-13-1019 Marian Number '� ` CMe'isd Block Sob-Marian bu%notoor CMA001 ' °C 0 Market Home Now York, W*J/Nassam-euflblk: lot BnBd-oat Date and Bofld-out Dab 3rd Bdld-oat Date 4t4 Build-opt Date 06.13-1019 Watvers/CoodWoas: If the f icilities outhoriaod hemin ale used to provide broadcast operadone,whether exclusively or in combination with other sevioas,the Noon see must seek renewal of the license either wlthbh eight yew nom the commencement of the broadcast service or widdm the term of the license had the broadcast sevioe not beet provided,whichaver period is,barter in length. See 47 CPR g27.13(b). Operation of tho hcilities wthorisaed herein,are subject to the condition do harmful tntefero nce nay not be caused to,but must be accepted Imm UHF TV trenumitters in Canada and Mexico as identified in existing and any future agreements with those countries. Conditions: Purwant to 13090)of the Communications Act of 1934,as amended,47 U.S.C.1309(hj,this license is subject to the following conditions: This license shall not vast in the licensee any right to operate the station nor any right In the use of the frequencies dedgnated in the license beyond the term thereof nor in any other manner than authorized heroin. Neither the license nor the tight granted thereunder shall be sasignW or otherwise transferred in violation of the Communications Act of 1934,as amended. See 47 US.C.1310(d). TMs bonne is subject in terns to the right of use or oontrol conferred by§706 of the Communications Act of 1934,a smended. See 47 U.S.C.4606. Thu licere may not suthodu operation dwoughout the entire geographic area or spectrum identified on the hmdcopy_version. To view the specific geographio was and speetn m authorized by this license,refer to the Spectnwn and Market Ana informaticm under the Market Tab of the license record in the Universal Liceaing System(ULS). To view the lioense rocod,go to the ULS homepage at hViAvimim.fbe.gov/uWinda.htrn?job bmw and select"Uanse Search". Follow the instructions on how to search for license information. FCC 601-MB Page l of 1 April 2009 B11F1IIIIIIII912 COPY We Is not no of oW FCC Remus.It Is a nowd a1fdWe ikon contained in the FCC*Uamda dstabsss on rhea date Ant this rat rsaw copy seas vxwatad.In oases wbws ACC rules ondre aw preddion,posdni or displey of an FM�em%,fhb domoaeat aayr not bs used In plats of an offlslal FCC lictrue. Federal Communications Commission O� lit. Wkdaaa Telco menu deadons Bureau RADIO STATION AUTHORIZATION J.ICHNSEE: AT&T MOBILITY SPECTRUM LLC 4` can 91ga File Number AM.FCC GROUP, " W iU424 AT&T MOBILITY SPISMUM LLC Raft$Wda 3601 LEGACY DRIVE,MS:A-3 W Y-700 M&Lower Band(Blocks A. _ PL ANO,TX 73024 B FCC Reoitradan Natmber t 0014960726 Grant Data Dtito Facpirdlan Dde Print Dale 01-06-2009 03-16 2010 ?`.; 06-13-2019 , Mw*d Number rt '`%Cltseed Black Bub�Market Designator CMAOOI 8 0 Market Nems New Y017t,NY-NJ/Nassau-Sutiblk lit Build-out Dale 2nd Budd-out Date 3rd Build-out Data 4di Build-oat Date 06-13-2013 06-13-2019 Walvers/Condttlonst If the Adlitia audwriaed herein we used to provide broadoad�ons,whether exclusively or in combb"on with other services,the licensee must seek renewal of the Mown either night your horn the a mntetoement of the broadcast service or within rho term of the licaue had the broadaet service not been provided,whichever period is shorter in length See 47 CFR 127.13(b). Candid st Punuunt to 1309(h)of the Communications Act of 1934,v amended,47 U.S.C.4309(h),this Home is subject to the following conditions: This license shall not vat in the licensee any right to operate the station nor any right in the use of the ft"umcia designated in the license beyond the term thereof nor in any other manner then authorized herein. Neither the license nor One right granted dominder shall be assigned or otherwise tranderrod in violation of the Coninwications Act of 1934,as amended. See 47 U.S.C.4 310(d). This Now=to subject in terns to the right of use or control con famed by 1706 of the Communications Act of 1934,d amended. See 47 U.B.C.1606. This license may no authorize operation dirmighout the attire geoV*k are or spectrum identified on the hw*opy version. To view the specific geographic as and spectrum authorized by this license,refer to the Spectrin and Market Ara itifti ntati under the Market Tab of the boom record in the Universal Ucerwing System(ULS). To view the license record,go to the ULS hotaepage at http://wwalow.foo.py/WiAndat.htm?jolrhome and select"License Sa rch". F,ollow the inswatiors an how to search for license information. FCC 603-MB Page 1 of 1 April 2009 UL's Noon-Cdkdu Limm-XNL4310-NSW CRMTAR 11V1 EIM PCOo LLC Pqp 1 o!2 !%6'.Jdom�11 pp41 12:mw 110 OM 11Eoc,L� 1 Emdam b NOJ' Universal Lioenslnp 60tmrr cc P.NM W8>QdOLIWAM s U�Swo l a uLs uou+m Cellular Lloenee - KNKA310 - NEW CINGULAR WIMLIM ®MaP PCB, LLC q of smarm ��'d'°�4a..d�` im°�°" �amoaaGomc ��► Lta�ou This uotruw A..petc�nP o.�Sion w�w10 PAft 00 N CL-wlkdr se ta. AcOo Auth TYa. R oww 1 -Hm WY- Ch omd No* A submork c 0 Phw DAM Ocan! w1orAM a cpl di, 10101/1016 QfhctlMtl 03/14m10 Omalhtlotl rbe Vow bdkbO Deft 03/17/2000 Copbol Poled 1 87 W.p"mMC STRIET•ROOM"PAN N3 Maromom Swft,810 7th Awnw.NOW York,WY ucww FRM (YIIR191lo0) T� LhnlC.d uebglLy Cafcprcnl► uoemom NfJW COWLAR W3NAM PCs,LLC im" 218-7471 =I UN ALY ORMs 10c A-3 F1060229-7297 pLANO TX 75024 sc l@ATT.COM ATTN gcz amp Oondat AT&T MOMM LLC MMwd P QMIn P: -3074 1110 20th sb•e,NW,SUM 1000 httpJ/wirele@Woo. 13092 *274010 ULW LAaea"-a dhdw U=M-XNKA310-NEW aNOULAR WIRMAN PCB,LLC Pop Z o(2 0 w..0 oc 200" e:�wnaeeO•etoom ATT1i�1 P.aopOpl. ownwddp aad Qwlplatttlons TWO pApkAory ate%= Co ninon c*rwtw inhwoormoded YM 'N0't0 WAh Of the quesuam 'Me anowwW OW t0 ach of tln QpWIl001dhD q� �--n-11 Roca RhOw Guider Ula N�Ip �i,Lf�ttttltLx'teQ- '�IIIIfL011WtILfi-l�Oeo11t0a�0p0ott W./OnUIM ��lia�0�OL1911tt4�1�LOrm!- ' About Wdt P�uoM 'J�OIRliB-lill�lomtt Wtas MtnrM *c is I C!!• PCC 1 bOml�1�Y 1 L'08M !!fit i I>�dtpaott Fedad OornnuatatloW Canty W= Mann i-A77•�60-ri01 445 13th BOW 6W TTYt i yi7- 3024 WaOhMl!t o CC 30M ,//wd�detr2.fbor00V ■r'..ai�ay"1309� S/Z7=10 RBPNIVICR COPY This Is not on of&W FCC Hoarse,It Is•- n d af pubtb Indbanstion contained in the PCB's Uosodas dWbMe as On dde taut We at6rame copy was generated.In cases wbe,e PM rules tegtdre the Presentation.path&or diWLy of ea PCC Vasoa%this doauooeot mqr not be used in phee of so otlloid FCC llcease Federal Communications Commission F Wiraten T de=Baratu VA RADIO JITATION AUTHOMUTION LICBNSBI;: NEW CINOULAR W13 ams PCs,LLC Ca118lga Me Number ATTN-.FCC GROUP WPOL311 N13W CINOULAR W1ltBl�S3 PCS,LLC name Barvia 3601 LBOACY DRIVB,M9:A-3 ' j.. CW PLANO,TX 73024 -PCS Broadband BCC 1111"W adoa Number(JPBN): 0003291192 Gram Date 1Llfbotivs Or1te:; B.xplradon Dab Prbnt Date 08-15.2007 03-16.2010 06-271017 Mad*Number ``rCpa ad Hbook Bub-Market Designator BTA321 w�x` r .E 2 molt Name New:dark,NY, let Bultd-cart Date 20d Btdid-oat Dab 3rd BdM-oat Data 4th Build-out Dab 06-27-2002 wabvers/Contudeve: This license is conditioned upon compliance with the providoas of Applicadcps of AT&T Wireless Services,hm.and CbWdu Wireless Capon don For Consent to Troui<er Control of Licenses and Authorizations.Memar*adum Opinion and Order,FCC 04.253(Tel.Oct,26,2004). Commission approval of this application and the Hamm contained dweinn are subject to the conditions set forth in the Memorandum Opinion and Order,adopted an December 29.2006 and released an M"26.2007.and revised In the Order an Reconsideration.adopted and released on Much 26.2007.See AT&T Inc.and BellSouth Cmparation Application fhr 7landhr of Control.WC Docket No.06-74,Memorandum Opinion and Order,PM 06.189(rel.Mar.26,2007),-AT&T Inc.and BellSouth Caparadon.WC Docket No.06.74,Order an Recondder atioa,FCC 07-44(rd.Mar.26,2007). Coaditlonst Punusnt to 1309(h)of the Communications Act of 1934,as smeW4 47 U.S.C.1309(hl this license is subject to dw following oondidans: This bases shall not vest in the licensee any right to operate the station nar amy right.in the use of tho frequencies designated in the Hamm beyond the term thereof nar in any other mennar than authorized herein. Neither do Boers nor the rlgM granted thereutader shall be assigned or odtawin transferred in violation of the Communications Act of 1934,as smaxkd. See 47 U.S.C.13 10(d). This liana Is subject in terms to the right of use or control conhired by¢706 of the Communications Act of 1934,as amended. See 47 U.S.C. This license may not sudxdn operation dzoughout the entire geoyapide arc or spectrum idemdIW at the hataicopy,version. To view the specific pe>WVlda area and spectrum art wdnd by this liceus,refer to the Speabvm and Market Area bdb<nnad Wunder the Market Tab of the license record in the Umiv=W Liaanshtg System(ULS). To view the Neese record,go to the ULS homepage at http://wireless.fcc.gov/Wo/in&x.htm?jab-home and select"License Scmh'. Follow the htetruadau an how to seauh for license information. FCC 601 MB Page 1 of 1 April 2009 BRPZUKCN COPY Thia 1s not sn oQidal FCC Hoene.It b a rsoord of pubUo bs�on contained is*@ FCC*licambg dstsbsse onto dab do ft rAmom COPY was{maQaoed b o m wbare FCC nsla nquim dw prnxftdan,l—+s•or dfgby of sO FCC Hosma,fleas doom Col m y notbe wad in place adan official FCC Ikons. _I. �'A Federal Communications Comn�iesion ' Wireless Teleoommunieadous Bureau ► !" RADIO STATION AUTHORIZATION UCBNSEB: NEWCINOULARWUMJlSSPCS,LLC ATTN:FCC GROUP, r �' V P8� llroe Number NEW CDVOULAR Wlltt3L9 ;PCl�Ixc 8adb 8ervloe 3601 LEGACY DRIVE.MS`'A-3,, ; PIANO,TX 75014 + ' CW-PCS Broadband 1rCC HagMtradon Number $N)s 0003291192 17 Grant Dab >Ei va Dalt .r B:plradon Date Print Dab 07-13-ZOOS OS-Q2.?A1 12-14-2014 Market Number `` ; Ct a ml no* Bob-Marital DsdRoatar MTA001 {°»=�l 15 MarltN'Name �lew York,. let Solid-0nt Dab 2nd Botld-out Dab 3rd,BuW-out Dab 411 Wl"ot Dab 12.14.1999 12.14-2004 Waivers/Cooditions Sp wtr=Leas associated with this license. See Spectnan Leasing Anungment Letter dated 12/07/2004 end Ffle No. 0001737186. Speetsmn Leasing Arrangement associated with file number 0001757186 was extended to 0110512009. See file manber 0001885143. Condttbn: Pursuant to#309(h)of the Cammunicadota Act of 1934,a unwmK 47 U.S.C.1309M this license is subject to the following conditions: This ho nse dull not vat in the licensee,any ri$M to operate the station nor any rigM in the use of the fiequeneies dedgnated in the lieerne beyond the tam dwW nor in any other nunner then authorized herein. Neidar the license nor the right granted thereunder shell be asipW or odwrwise Transferred in violation of the Communications Act of 1934,as amended. Sea 47 U.S.C.1310(d). This license is subject in terms to the right of use or control eonfarred by#706 of the Comwdeations Act of 1934,as amended. See 47 U.S.C.I606. This license may not authorise operation tlmmrghout the shire geowspbic area or spectrum identified on the hsidcopy vetdan. To view the specific geographic am and speolrum authorised by this lacunae,rdbr to the Spectrum and Market Anew lnfbnmda under the Market Tab of the license teoord in the Universal Lianaing System(ULS). To view the license reooed,go to the ULS homepage at httpJ/wirsion.fee.gov/uWindmhtmtob-Mme and select"License Search". Follow the itatrucdons on how to eearcb for license infbm adon. FCC 601-MB Page 1 of 2 April 2009 Weaves Nam; NEW CINGULAR WIRBIMS PCS,LLC Call 818111 WPSIA26 File ltTtrmbert Print Debt Ckmit isdon sp rovel of this.oppliatlaa and the lioeoea ooubbsed lfiotein we&Nam to the oanditibu aet ft&in the Mernorandurrr=bn rind Order,adopted an Dec=iber 29,2006 and ralaaed on Mnreh 26,2oo7,aaad rariasd 111 the Order on ------ daastiarr,adopted and released on March 26.2007.Sea AT&T Ina.end Benflou@r Corporation Appiloadom for Tme w of Coutrol,-WC Docket No.06-74,Me®ara ndi n Ophdon and Omer,PCC 06.189(rel.Mar.26.2007).-AT&T bm.end BellSouth Corporation,WC Docket No.06-74,Order an Raoao&bmdon,FCC 07-44(rd.Mar.26,2007). FCC 60l MB Page 2 of 2 Aprli 2009 R1PRMC2 COPY This knot sn offioW ACC Hamrse.It is s asord of pablio fofbeoa Lion coudosd in the FCCs llosaiag datebsse on the date that tide rdwo:se oopy was generated.h oases whers FCC rules require the presa dedoo,pieties,or display of so FCC Hanes,tads doomunt may act be wed In place of so oflidsl FCC license. , Federal Commanleadons Commbelon NVWns Tdeoommnnfations Bureau ,.4�\ RADIO STATION AUTHORIZATION LICBNSIM: NEWCIN6Ui.ARWMMJlSSPCS,LLC Consign ne Number ATTN:FCC t3Ri0UP °` ` WQ00892 NBW CINQULAR WJ RBLMS PCS,LLC Raft 8erOoa 3601 LSOACY DAIVB,MS:A-3 f '; CW-FM Broadband PLANO,TX 75024 FCC Ragletradan Namber(PAN)` 0003291192 Girant Dote liAbWvt Dale Xxpirsdion Dub Psiat Dab 1121 2006 034."2010 ; ', 12-14.2014 Manua Numbr �Y `� Cbaptrd mock Snb•Marltet Desipabr M1'A00I "A 14 •-r Marltet Name New Yaic 1st Bmiid out Drat 2nd Bnlld-ont Data 34 Build-ont Date 41h Balld-ottt Dab walven/Comdltions: Nth Comdkions: Pum mnt to 8309(h)of tho Communications Act of 1934,a ammuK 47 U.S.C.I309(hl this license is subject to the following conditions: This license shall not vest in the liomteee my right to operate the station nor any right In the tree of the frequencies designated in the license beyond the team thereof nor in any other manner than authorized herein. Neither the lioetse nor the right`ranted d etmm*"I be assigned or otherwise t um%rmd in violation or the Cormnunicatioru Ad of 1934,as amended. See 47 U.S.C.13 10(d). This bastes is subject in toms to the right of use or control can&nW by¢706 of the Conmtnmtications Act of 1934,a amended See 47 U.S.C.1606. This licetae may not authorize operation throughout the andrs gaoF*do arm or spectre ldmtdfled on thihsr&opy.veraicn. To view the elmiflc geogropMa area and simu m sdhoimd by this license,refer to the Spectrum and Mobt Area Inkmatiom under the Market Tab of the license record in the Univecal Licensing System(UI.S). To view the banana record,go to the ULS homgmV at http:/Mrolon.fbc.gov/We&Wu.htm?job-bone and select"License Search". Follow the instructions on how to search for license infbrm don. FCC 601-MB Page l of 1 April 2009 100 Paragon Drive Montvale,NJ 07645 AW Tel: (201)571-0650 Fax: (201)5710763 May 2,2013 Mr.Joseph Sweet New Cingular Wireless PCS, LLC("AT&T") 340 Mt.Kemble Avenue Morristown, NJ 07960 Subject: Structural Analysis Report AT&T Site ID#: NYNYNY0801 AT&T USID#: 35798 AT&T Site Name: FISHERS ISLAND S OVERLAY Oriental Ave and Ettrick Ave., Fishers island, NY 06390 Latitude: N 410 15'38.70"; Longitude:W 720 00'51.99" Dear Mr.Sweet: Bechtel Associates Professional Corporation is pleased to submit this"Structural Analysis Report"to determine the structural integrity of the existing antenna support structures at the above mentioned telecommunication facility. The site was visually inspected during a site visit occurring on December 6,2012. The steeple interior members,the connections of the masts,and the building itself were found to be in good visual condition. Destructive testing/investigation methods were not employed during the inspection. The existing AT&T equipment is mounted on the inside of the steeple in for all sectors. The proposed scope or work consists of swapping(1)antenna in each sector,as well as the addition of(6)remote radio heads added in the steeple. The existing and proposed mounting hardware has been analyzed to handle the existing and proposed loadings. The existing mounts have the structural capacity to support the proposed configuration as shown in the construction drawings. Based on our analysis,we have determined that the existing mounts are structurally adequate to proceed with proposed work in accordance with the requirements of the Building Code of the State of New York— 2010 and TIA/EIA-222-F(1996). Of NE�V �P Pao M 0 Respectfully submitted by: Gj V'r 0 Q w W 2 C? Richard M.Coad, P.E. O 045439•, NY License#045439-1 A;90FESSIONP� Bechtel Associates Professional Corporation Calculation Cover Sheet PROJECT: NEW'CINGULAR JOB NO.: CALC NO.: SHEET: WIRELESS PCS, 25736 25736-415-A3C-EF-00100 1 of 13 LLC AT&T Subject: NYNYNY0801,NY RT(Antennas) Discipline: Civil/Sbvctural CONFIRMED WITH CALCULATION PRELIMINARY PRELIMINARY CONFIRMED SUPERSEDED VOIDED STATUS INFORMATION DESIGNATION ❑ ❑ 0 1 ❑ ❑ NUCLEAR QUALITY SAFETY-RELATED I AUGMENTED QUALITY NONSAFETY-RELATED I NON-NUCLEAR CLASSIFICATION ❑ ❑ ❑ 0 COMPUTER PROGRAM INFORMATION-REFER TO COMPUTER PROGRAM INFORMATION SHEET DESIGN VERIFICATION REPORT SDN FOR REV (SAFETY-RELATED&AUGMENTED QUALITY ONLY); LEAVE BLANK IF DVR IS INCLUDED IN CALCULATION. Note: Use of these calculations by persons without access to pertinent fact=upon which these calculations are based,and without proper regard for`ther purpose,could/sad to erroneous conclusions. Should it become necessary to use these calculations for work in the future,it is recommended that the calculabons be reviewed with suthatzed Bechtel personnel to ensure that Me purposes assumptions,judgments and limitations are thoroughly understood. In addition,these calculations may contain confidential lift motion proprietary to Bechtel Corporation that is not to be used,disclosed,or reproduced in any hr mat by any non-Bechtel party without BechWs prior written permission. Notwithstanding the above,AT&T has the dqN to use the inkmrmabon contained in this document pursuant to the Contract between Bechtel Corporation and AT&T. Structure:PASS Bechtel Associates Professional Corporation 5295 Westview Drive Frederick,MD 21703 002 Revised as noted 44 Att.F,Sht.2 KD AKS 001 Revised as noted 44 Att.F Sht.2 KD AKS 3/22/13 000 issued for use 46 Att.F,Sht.3 KD AKS 3/14/13 REV. REASON FOR TOTAL NO. LAST BY CHECKED APPROVED/ DATE NO. REVISION OF SHEETS SHEET NO. ACCEPTED RECORD OF REVISIONS Bechtel Confidential O Bechtel Associates Professional Corporation 2013.Contains confidential andfor proprietary information to Bechtel and its affiliated companies which Mall not be used, disclosed or reproduced In any format by any non•Bedrtet party without Beehtefs prior written permission.AN rights resenrod. Calculation Sheet New Cingular Wireless PCS,LLC Subject:NYNYNY0801,NY RT(Antennas) Job Number:25736 Project: ("Aject: Date: 4/1/2013 Calc. No.: 25736-415-A3C-EF-00100 Originator: Kaladhar Dheram Checker:Amit Kumar Singh Sheet No.: 2 of 13 Sheet Rev.: 002 Table A: Computing Environment Computer Type X IBM Compatible Desktop PC IBM Compatible Laptop PC Other(specify) Operating System X Windows 7 Windows 7 with VMware(virtual DOS) Windows XP DOS Citrix server Other(specify) Table B: Computational/Analytical Computer Programs List all computational/analytical computer programs used to produce calculation. Note: If the program is not an SCP, then the verification package must be included (or referenced)in calculation, or the results must be verified by alternate means (hand calculation, etc.). Name of Program(s) CSL Program No. Version/Release SCP (Yes/No) STAAD. Pro CE242 20.07.06.35 Yes N/A N/A N/A Bechtel Confidential ©Bechtel Associates Professional Corporation 2013. Contains confidential and/or proprietary information to Bechtel and its affiliated companies which shall not be used, disclosed or reproduced in any format by any non-Bechtel party without Bechtel's prior written permission. All rights reserved. Calculation Sheet Subject:NYNYNY0801, NY RT(Antennas) Job Number:25736 Project: New Cingular Wireless PCS,LLC Date: 4/1/2013 Calc. No.:25736-415-A3C-EF-00100 ("AT&T') Checker:Amit Kumar Singh Sheet No.: 3 of 13 Sheet Rev.: 002 Originator: Kaladhar Dheram Table Q Validation Testing Method Used This table required only for nuclear safety-related or augmented quality calculations Select the validation testing method used. Note: The purpose of validation testing is to ensure the computer program is functioning correctly in the computing environment in which it is installed. The validation test is required if not performed within the preceding 24 hours, OR if the application has been re-loaded OR the configuration of the workstation has been altered OR failed elements replaced. Computer Program satisfactorily completed a front-end validation (built-in self-test). A test problem was run and the results matched known accurate output(previously verified solution or manually calculated results). X Not applicable. Table D: Utility Computer Programs List all utility programs used to produce the calculation. Note: Utility programs are not considered verified software. If utility programs are used to perform any computational/analytical functions, the output must be manually (hand)checked. Word Processing MS Word Version: Other(specify): Version: Spreadsheet I IMS Excel Version: Other(specify): Version: Math Utility I X IMathCAD Version: 15.0 M010 Other(specify): Version: Drawing I Ivisio Version: Other(specify): Version: Miscellaneous Other(specify): Version: Other(specify): Version: Bechtel Confidential ©Bechtel Associates Professional Corporation 2013. Contains confidential and/or proprietary information to Bechtel and its affiliated companies which shall not be used, disclosed or reproduced in any format by any non-Bechtel party without Bechtel's prior written permission. All rights reserved. Calculation Sheet Subject:NYNYNY0801,NY RT(Antennas) Job Number:25736 Project: New Cingular Wireless PCS,LLC Date: 4/1/2013 Calc. No.: 25736-415-A3C-EF-00100 ("AT&T') Checker:Amit Kumar Singh Sheet No.:4 of 13 Sheet Rev.: 002 Originator: Kaladhar Dheram Table E: Computer Program Checklist Note: All items in the checklist should be checked "Yes"or"NA"before using the results. Yes No N/A Checklist Items X Was the computer program authorized for use by the Chief Engineer(either by inclusion in the Discipline Appendix to 3DP-G04G-00036 or by DRN)? Does the computer program version and operating system match that authorized for use by X the Chief Engineer(either as listed in the Discipline Appendix to 3DP-G04G-00036 or approved by DRN)? X For SCPs, was the computer program and documentation obtained by the user from the Computer Services Library (CSL)? For SCPs, did the user review the SCP User Guide/Manual to determine any parameter X limits or usage limitations and to ensure that any software modules/options/features used in the calculation have been validated/verified for use? X If there are project-imposed restrictions on the use of software(e.g., Project Automation Plan, etc.)? If so, is this software acceptable for use? If Safety-Related(SR)/Augmented Quality (AQ)calculation, has the discipline Chief X Engineer authorized the use of the computer program in SR applications (either in the Discipline Appendix to 3DP-G04G-00036 or approved by DRN)? Was the latest version of the program as listed on the Discipline Appendix to 3DP-G04G- X 00036 used (or alternately was approval to use a different version obtained from the Chief Engineer via DRN)? X Were all available Computer Program Error Notices (CPENs)affecting the software reviewed for applicability? X If SCP, is the user individually registered with the CSL as an authorized user of the program? X For non-SCPs, was the verification package included (or referenced)in the calculation, or were the results otherwise verified (manual checking, etc.)? X If utility programs such as Mathcad or Excel were used, were all the results verified by other means (manually checked, etc.)? X JAre the computer program inputs and outputs included in the calculation package? If any"No"boxes were checked, use this space to justify use of the software in this calculation: Bechtel Confidential ©Bechtel Associates Professional Corporation 2013. Contains confidential and/or proprietary information to Bechtel and its affiliated companies which shall not be used, disclosed or reproduced in any format by any non-Bechtel party without Bechtel's prior written permission. All rights reserved. Calculation Sheet Nro ect: New Cin ular Wireless PCS,LLC Subject:NYNYNY0801,NY RT(Antennas) Job Number:25736 1 g Date: 4/1/2013 Calc. No.: 25736-415-A3C-EF-00100 ("AT&T") Checker:Amit Kumar Singh Sheet No.: 5 of 13 Sheet Rev.: 002 Originator: Kaladhar Dheram TABLE OF CONTENTS Section Description Sheet Number 1.0 Purpose 6 2.0 Design Basis 7 3.0 Criteria 7 4.0 Assumptions 7 5.0 References 7 6.0 Calculations 8 7.0 Recommendations 13 8.0 Conclusion 13 Ref. Description Number of Sheets A RFDS Rev.V03, Dated January 31, 2013 7 B Proposed Antenna/ Equipment Data Sheets 5 C Reference Drawings 2 D IPhotos 3 E ISTAAD Output 12 F IReference Sketch 2 Bechtel Confidential ©Bechtel Associates Professional Corporation 2013. Contains confidential and/or proprietary information to Bechtel and its affiliated companies which shall not be used, disclosed or reproduced in any format by any non-Bechtel parry without Bechtel's prior written permission. All rights reserved. Calculation Sheet Nro�ect: New Cingular Wireless PCS,LLC Subject:NYNYNY0801,NY RT(Antennas) Job Number:25736 Date: 4/1/2013 Calc. No.: 25736-415-A3C-EF-00100 ("AT&T") Checker:Amit Kumar Singh Sheet No.: 6 of 13 Sheet Rev.: 002 Originator: Kaladhar Dheram 1.0 Purpose The purpose of this calculation is to verify the structural capability of the existing and proposed antenna mounts at the NYNYNY0801 site located at Oriental Avenue and Ettrick Avenue, Fishers Island, Sufflok County, New York to support the proposed antennas and ancillary equipments as a part of the AT&T LTE Wave 4 scope. Table 1 -Proposed Antennas and Ancillary Equipment Sector E/P/F Qty. Type Make Model �) Location Proposed 1 Antenna Quinte/ QS6658-2 35.0 Pipe mounted inside Steeple Alpha Proposed 1 RRH Alcatel 9442(A WS) 35.0 do Proposed 1 RRH Alcatel 9442(700 MHz) 35.0 do Proposed 1 SumaProt-or Raycap DC6.48-60-18_8F 35.0 do Proposed 1 Antenna Quintet QS6658-2 35.0 Pipe mounted inside Steeple Beta Proposed 1 RRH Alcatel 9442(A WS) 35.0 do Proposed 1 RRH Alcatel 9442(700 MHz) 35.0 do Proposed 1 Antenna Quintet QS6658-2 35.0 Pipe mounted inside Steeple amma Proposed 1 RRH Alcatel 9442(A WS) 35.0 do Proposed 1 RRH Alcatel 9442(700 MHz) 35.0 do Table 1 Notes: 1. Existing equipment not modified as part of the proposed scope of work will not be included in this table. Bechtel Confidential ©Bechtel Associates Professional Corporation 2013. Contains confidential and/or proprietary information to Bechtel and its affiliated companies which shall not be used, disclosed or reproduced in any format by any non-Bechtel party without Bechtel's prior written permission. All rights reserved. Calculation Sheet Subject: NYNYNY0801, NY RT(Antennas) Job Number:25736 rrolect: New Cingular Wireless PCS,LLC Date: 4/1/2013 Calc. No.: 25736-415-A3C-EF-00100 ("AT&T-) Checker:Amit Kumar Singh Sheet No.: 7 of 13 Sheet Rev.: 002 Originator: Kaladhar Dheram 2.0 Design Basis The design wind speed is based on ASCE 7-05. 3.0 Criteria 1. TIA-222-F Standard-Structural Standard forAntenna Supporting Structures and Antennas 2. The Building Code of New York State-2010 Edition 4.0 Assumptions 1. It is assumed that the original design, material production and classification, fabrication and erection of the structure was performed in accordance with accepted industry design standards and methods. 2. It is assumed that the existing structure and its attachments have been properly maintained in accordance with the referenced standards and/or the manufacturer's requirements and are in good condition with no structural defects and with no deterioration to its members. 3. It is assumed that the manufactured structural and nonstructural elements and attachments are load-rated, designed and fabricated in accordance with accepted industry standards for design, materials and workmanship. 4. It is assumed that member or section shapes, sizes, and materials are accurate as provided in the referenced documents. 5. All equipment, antennas, mounts, coax and wave guides are assumed to have been properly installed and supported as per the manufacturers requirements. 6. All welds and connections are assumed to develop at least the member capacity, unless determined otherwise. 7. All prior structural modifications, if any, are assumed to have been properly installed and to be fully effective. 5.0 References 1. The Building Code of New York State-2010 Edition 2. ASCE 7-05 Minimum Design Loads for Buildings and Other Structures. 3. AISC Manual of Steel Construction- 13th Edition. 4. National Design Specification for wood construction-2005 Edition. Bechtel Confidential ©Bechtel Associates Professional Corporation 2013. Contains confidential and/or proprietary information to Bechtel and its affiliated companies which shall not be used, disclosed or reproduced in any format by any non-Bechtel party without Bechtel's prior written permission. All rights reserved. Calculation Sheet rolect: New Cingular Wireless PCS,LLC Subject:NYNYNY0801,NY RT(Antennas) Job Number: 25736 N ("Aject: Date: 4/1/2013 Calc. No.:25736-415-A3C-EF-00100 Checker:Amit Kumar Singh Sheet No.: 8 of 13 Sheet Rev.: 002 Originator: Kaladhar Dheram 6.0 Calculations Table 2-Antennas and Ancillary Equipment Specifications Dimensions(in.) Type Make Model Height Width Depth Weight(lbs) Antenna Quintel QS6658-2 72.5 12.0 9.0 79.0 RRH Alcatel 9442(700 MHz) 21.0 12.2 10.8 51.0 RRH Alcatel 9442 (AWS) 25.0 12.0 9.0 43.0 DC6 Raycap DC6-48-60-18_8F 23.5 9.7 9.7 20.0 Design Antenna Dimensions Height hart:= 72.5in (Table 2) Width want:= 12in (Table 2) Depth dst:= 9in (Table 2) Weight Wart 791bf (Table 2) Design RRH Dimensions Height h,,h:= 25in (Table 2) Width wnh:= 12in (Table 2) Depth dr<h:= 9in (Table 2) Weight WRh:= 511bf (Table 2) DC6 Dimensions Height hdc6:= 23.5in (Table 2) Width W&6:= 9.7in (Table 2) Depth d (Table 2) dc6:° 9.7in Weight Wd,6:= 201bf (Table 2) Bechtel Confidential ©Bechtel Associates Professional Corporation 2013. Contains confidential and/or proprietary information to Bechtel and its affiliated companies which shall not be used, disclosed or reproduced in any format by any non-Bechtel party without Bechtel's prior written permission. All rights reserved. Aw Calculation Sheet Nro ect: New Cin ular Wireless PCS,LLC Subject: NYNYNY0801,NY RT(Antennas) Job Number: 25736 1 g Date: 4/1/2013 Calc. No.:25736-415-A3C-EF-00100 ("AT&T") Checker:Amit Kumar Singh Sheet No.: 9 of 13 Sheet Rev.: 002 Originator: Kaladhar Dheram Pipe dimensions Existing and proposed pipe mounts are assumed to consist of 2" Std steel pipe(ASTM A53 Gr. B, Fy 35ksi)as a conservative assumption. Pipe Diameter dpipe := 2.38in For 2" Std Pipe(Ref. 3, Table 1-14) Pipe Weight Wpipe:= 3.66plf For 2" Std Pipe(Ref. 3, Table 1-14) Total Length of Pipe Lpip to,:= 7.5ft (ReferAttm. C) Total Weight of Pipe Wpipe.tot Wpipe•Lpipe.tot =27.51bf 6.1 Design Loads A)Dead Load Antenna Weight Want=791bf Pipe Weight Wpipe=3.66•plf Proposed RRHs Weight Wnh_t= 2Wrrh+ Wpipe.tot= 129.451bf Weight of Antenna and DC6 Wcombined Want+ Wdc6 + Wpipe.tot= 126.45 Ibf B)Wind Load ,As the antennas are enclosed inside a steeple, it is assumed that the antennas are shielded from wind. Bechtel Confidential ©Bechtel Associates Professional Corporation 2013. Contains confidential and/or proprietary information to Bechtel and its affiliated companies which shall not be used, disclosed or reproduced in any format by any non-Bechtel party without Bechtel's prior written permission. All rights reserved. Calculation Sheet Project: New Cingular Wireless PCS, LLC Subject:NYNYNY0801,NY RT(Antennas) Job Number: 25736 Date: 4/1/2013 Calc. No.: 25736-415-A3C-EF-00100 ("AT&T') Checker:Amit Kumar Singh Sheet No.: 10 of 13 Sheet Rev.: 002 Originator: Kaladhar Dheram Exlsttng Lag Bolts of 3/8"dia(TYP.2) Existing L9"x4"X1/2" Angle Proposed RRH's 1' <---Wooden Strut(4"X2") 7.5' Proposed 2" Dia.STD Steel Pipe 1' U-Bolt(TYP.2) A 307 Gr. Bolt(TYP.2) Figure 1: Sectional View of Proposed Equipment Arrangement 6.2 Analysis Each sector contains (2)pipe mounts. The existing pipe mount accommodates the antenna and DC6. The proposed pipe mount accommodates (2)RRH's.As there is no wind load, dead load is governing. As, the combined weight of RRH's is greater than the sum of weights of antenna and DC6( Wnh_t>WeOmbi„ed), the analysis of proposed pipe mount is done. Check Flexure The antenna pipe is safe as per Staad analysis with maximum interaction ratio of 0.003 for Members 1 and 3 for Load case 3 . Refer to Attachment E for detailed information. Bechtel Confidential ©Bechtel Associates Professional Corporation 2013. Contains confidential and/or proprietary information to Bechtel and its affiliated companies which shall not be used, disclosed or reproduced in any format by any non-Bechtel party without Bechtel's prior written permission. All rights reserved. Calculation Sheet Subject:NYNYNY0801,NY RT(Antennas) Job Number: 25736 Project: New Cingular Wireless PCS,LLC Date: 4/1/2013 Calc. No.: 25736-415-A3C-EF-00100 ("AT&T") Checker:Amit Kumar Singh Sheet No.: 11 of 13 Sheet Rev.: 002 Originator: Kaladhar Dheram Check A nc horages A)Check for U-bolts Support Reactions from Py:= 65.991bf (ReferAttm.E, Sheet#11, LC3 ) Staad for node 1 Assuming 1/2" dia. U-bolt 2 Area of bolt Abott:= 4 2 in) =0.2•in2 Nominal Shear Stress in bolt Fnv:= 48ksi (Ref. 3,Table 7-1) Safety factor for shear SEt := 2 Allowable shear strength of bolt V Fns u 'Abou= a �_ 4.71•ki P t Shear at support (along y-direction) Vy:= Py=65.99lbf Number of U-bolts nbott:= 2 V Shear force in single arm of U-bolt Vacs 4y = 16.51bf < Vall Interaction Ratio, IR r Vact21 =0.0035 less than 1.0, Hence OK Vau Bechtel Confidential ©Bechtel Associates Professional Corporation 2013. Contains confidential and/or proprietary information to Bechtel and its affiliated companies which shall not be used, disclosed or reproduced in any format by any non-Bechtel party without Bechtel's prior written permission. All rights reserved. Calculation Sheet Project: New Cingular Wireless PCS,LLC Subject: NYNYNY0801,NY RT(Antennas) Job Number:25736 ("AT&T') Date: 4/1/2013 Calc. No.:25736-415-A3C-EF-00100 Checker:Amit Kumar Singh Sheet No.: 12 of 13 Sheet Rev.: 002 Originator: Kaladhar Dheram B)Check for lag screws Anchor bolts are connecting the existing angle section (9"X 4"X 1/2")to the wooden stud (Assumed Douglas Fir-Larch of 4"X 2"). Note 1: The existing angle section supports (1)proposed pipe mount ((2)RRH's mounted)and (1)existing pipe mount ((1)DC6 and (1)Proposed Quintel QS6658-2 Antenna mounted). As the pipe mounts are inside a steeple, they are assumed to be shielded from wind. Hence, dead load is governing. As the dead load of the proposed mount is comparable to the dead load of the existing mount (Wrrb t—Wcombi.cd=3 lbf ), it is conservatively considered that the existing angle section supports (2) I proposed pipe mounts. As the staad analysis is performed for single proposed pipe mount, the support reaction is multiplied by a I factor of 2, to account for the presence of(2)pipe mounts. Considering lag bolts of 3/8" dia and the minimum embedment of 3" (Eight times the bolt diameter) Check Lateral Loading (Per Ref. 4, Section 11.3) Assumed Reference Lateral Design Value (For Side member thickness (ts)of 1/4 in and Specific Gravity(G)of 0.50) Lateral Load Parallel to Grain ZII:= 2801bf (Ref. 4, Table 11K) Lateral Load Perpendicular ZL:= 1801bf (Ref. 4, Table 11K) to Grain Load Action Factor CD:= 1.0 (Ref. 4, Table 2.3.2) Wet service factor CM:= 1.0 (Ref. 4, Table 10.3.3) Temperature factor Ct:= 1.0 (Ref. 4, Table 10.3.4) Group Action factor Gross Cross-sectional area of Wooden stud Aswd:= 4in-2in= 8-in 2 (ReferAttm. C) Gross Cross-sectional area of Ae„gle:= 9in•0.5in=4.5•in2 Angle Number of fasteners in a row nrow 1 Bechtel Confdentlal ©Bechtel Associates Professional Corporation 2013. Contains confidential and/or proprietary information to Bechtel and its affiliated companies which shall not be used, disclosed or reproduced in any format by any non-Bechtel party without Bechtel's prior written permission. All rights reserved. Calculation Sheet Project: New Cingular Wireless PCS,LLC Subject:NYNYNY0801,NY RT(Antennas) Job Number: 25736 1 Date: 4/1/2013 Calc. No.: 25736-415-A3C-EF-00100 ("AT&T') Checker:Amit Kumar Singh Sheet No.: 13 of 13 Sheet Rev.: 002 Originator: Kaladhar Dheram Ratio of Gross Cross-sectional Astnd areas of wooden stud and angle ratio:= A = 1.78 angle Hence, Group Action factor Cg:= 0.98 (Ref. 4, Table 10.3.6C) End Grain factor Ceg 1.0 (Ref. 4, Section 11.5.2) As there is no withdrawal (tension)force on the screws, neither is the axis of the screws parallel to wood fibers Geometry factor Co:= 1.0 (Ref. 4, Section 11.5.1) Diaphragm factor Cdi:= 1.0 (Ref. 4, Section 11.5.3) Toe Nail factor Ctn:= 1.0 (Ref. 4, Section 11.5.4) Number of threaded rods er support n 6 =3 (ReferAttm. D) I P PP lag.z= 2 � Nominal Lateral Load Zlag.n:= min(ZII,ZL) = 1801bf Allowable Lateral Load Z'lag Zlag.n'CD•CM•Ct•Cg•CA-Cee Cdi'Ctn (Ref. 4 Table 10.3.1) Z'lag= 176.4 IV 2P Lateral Load on (1)Threaded Rod Rlat:= y =43.991bf ( Refer Note 1 on Page#12 ) nlag.z I Check Lateral Loading Checklag.tat if(Z'lag>Rlat,"OK" ,"NO GOOD") ="OK" Lateral Interaction Ratio 1R1ag lat:= Rlat =0.25 Hence, OK Z lag 7.0 Recommendations Install new pipe mount (2" STD pipe, minimum length 7.5ft)for mounting RRH's.A new angle (L 9"X 4" X 1/2")shall be connected at top and bottom each to the existing angle(L 9" X 4"X 1/2")using 2 nos of A307 1/2" dia bolts. The new pipe mount shall be connected to the new angle using 1 no of A307 1/2" dia U-bolt each at top and bottom. 8.0 Conclusion The proposed, existing mounts and wooden steeple structure are adequate to support the proposed antenna and ancillary equipment configuration as shown in Table 1. Bechtel Confidential ©Bechtel Associates Professional Corporation 2013. Contains confidential and/or proprietary information to Bechtel and Its affiliated companies which shall not be used, disclosed or reproduced in any format by any non-Bechtel party without Bechtel's prior written permission. All rights reserved. Calc. No.: 25736-415-A3C-EF-00100 Attachment A Rev. 002 Sheet 1 of 7 Release Notes USID: 35798 FA Location: 10097475 Site ID:NYNYNY0801(UMTS ID:NYNYU4801 YNYLO4801 Site Name:FISHERS ISLAND Vol 04/05/12 ".•Initial Version LTE RF design.RRHs should be mounted closer to the Equipment.The radio count for GSM is based on the latest BCCH file.Keep the existing azimuths of 70-240-310 since the site is in V02 a church Steeple.NOTE:The existing 4'antenna has been swapped with a 6'antenna.In order to keep the top of the new antenna at the same height of the previous antenna the Rad 10/11/12 Center has been lowered by a foot. Revise the RFDS to propose the RRHs in the space available,closer to the Antennas,as per Engineering.The proposed diplexers and TMA are no longer required.NOTE:Mount the V03 01/31/13 RRHS closer to the antenna. a« a 14 -1 110 Swap the existing Decibel 731 DG65VTAXM antenna with an 8-port Quintel QS6658-2 antenna for GSM/UMTS/LTE700.Install RET cable. Sector Alpha: Use all four(4)7/8"coaxes for GSM/UMTS. NOTE:The RRH should be mounted closer to the antenna for LTE. Swap the existing Decibel 731 DG65VTAXM antenna with an 8-port Quintel QS6658-2 antenna for GSM/UMTS/LTE700.Install RET cable. Sector Beta: Use all four(4)7/8"coaxes for GSM/UMTS. NOTE:The RRH should be mounted closer to the antenna for LTE. Swap the existing Decibel 731 DG65VTAXM antenna with an 8-port Quintel QS6658-2 antenna for GSM/UMTS/LTE700.Install RET cable. Sector Gamma: Use all four(4)7/8"coaxes for GSM/UMTS. NOTE:The RRH should be mounted closer to the antenna for LTE. Sector Delta:.; a Sector Epsilon: Senor Psi: �;:�'�rah .:.��c�.�.F. � r?'n i5 r..�., J�•. �,::�.. � `� -;.�. • 1 1 1 1 1 SSeGO�t�Ri056EIffRAlN6pRWTgN 3_L? ccw.4�iOtAT10NNFORMg1gN K_.et_tu INPORMaTNM 31 •.r,' __f�ii. _��_ 5xa�m ii R839P IFIL INRORNpigN !!..! L RS(Err,IrSt T�f^- T".T- JNEWVPROPOSER RgOq COUNi.4 cucm m;-- mu�— rw roe m .e owa�- rau— tvav[nwxvwwv BMbN<*pWIK@p(';AWEVd�WW1kWONIWtriWI'• F ;�u.. �'.L�i"/.a�'e�''.?C�A`:&,iz'a% %. YYO Y Y x octa rnx.xmrcwmavur wwett— you rax umcui x roE�i—_ mwuu[x wxrnnow 3edA nt3C-�GVRMBI!4�.'104R.'ID3.NMIMtA4.B.1 W iCIR'19d� mr r � rx arr- rx�m.nncwmo.uxrti mm— wuroc s meu— wcv[nwxuncw [u=�1— YY YYYY� ;F �0 4i xWhi/G- '!PROP06FdSFCTUF IeFY,}wppkYA�'9#1�4kWFa a� .:-:, ,,,•.:. ;-. :. ...»,,.a,c.; .. ucx t�. ,:s.am..�-NewRrtososeoaFCrowcaa+ mr-oe.*• ,. .atiz•�•• ,: :. ':,k..iro w,,... •i:: :� ,. ... .. o, ',. :a.mea+ce-�sFSrp.+.cauus,FOFMAiWM•ersa«r milli a:.e.: ..,,. �•i. ,e,: ::. Wniw.t6F•M.qWR+�>dSFOSBetolW7fei:uiLRwtax-ev Calc. No.: 25736-415-A3C-EF-00100 Attachment A Rev. 002 Sheet 5 of 7 LTE R-v1.1on: V03 rrotutad Configmil n-Sector A Date: 113102013 MR9)a'a 1 OI YLSYOBM1MbUMfS ISNIMT81f001LTETGO x x x x x x x x x x x x x x u, 1 �w,wc rnlwn� 1 � 1 1 ' sGt11Re 700 W.1 ' Mel 1 8 -A � S-ebrA I I 1 I 1 � 1 tAMIM s I ......_._t UMTS1a0a Rr UMTSOSO GsM9so ......._._.......... _.....__..._ s 3 i WTSB60 GSM1900 .____ _____ ______ Ra G9Ma50 ' aR raxx AR nrnll � I 1 _____ ------___________________ _________ _____________I 1 1 1 11 1 I 1 1 I 1 II 1 1 1 11 1 1 1 1 11 1 1 1 1900 850 I ' II ' UMTS UP:1`S I 1 1 I 9 of Rad o:2 9 d Radio:1 i Nof WBC1 n :of WBC:0 1 1 1 11 1 I I 11 1 1 1 j 'IDEA MODE B 1 � ii I 1 ' 1 1 GSM19OO GSYSaO I 1 I i II 1 II Cabinet Y 9 UMTS-Sector A B 6 i i Cabinet 31(GSM/900-Salon ABBC) li Cabinets 2(GSMBSO-Sedan AB&C) ' �----------------------------' I II 1 BBu EeER INNA T° Ibladea NVNYNVOBat(UMTS D:NYNVlMa017NYL01901 Calc. No.: 25736-415-A3C-EF-00100 Attachment A Rev. 002 Sheet 6 of 7 LTE R.vblon: V03 Propw.A Cmfig atbn-S.el.r B DM.: 1/31/2013 ANTWM 1 9aMaenro9M1MWOMf9.1MAIT91. TETM x x x x x x x x x x x x x x mt "mwt� t ir�mwa T00 RI.1 1 FUMtE 1 Pl1M 1 s.awre � s.al.r9 � 1 ' 1 � a i UMTSta59 t 1 UMTSIBMIA •, UMT5550 c9nt0$B i i i UM1565e fa'SM1800 _____ _____ ______ _____ RI 1 1 11 1 1 I II I 1 1 1 1 II 1 1 1 II 1 1900 850 1 1 UMTS Uk1l`S ; II #ofWBC.2 i� #.fRB ' #dwec:l #erweC-O c:o 1 1 1 i ii 1 1 I I I I 1 fIBF. i I 1 NODE B II � i n ' 1 1 1 i ' GSM1900 i:::Y30 II 1 1 1 1 i li i i Cabin.t 93(UMTS-Sect A.B B C) i 1 C.W..t 01(GSM1900-Saet—A ft BSC) n Cbl-t02(GSMSSO- e—A,B&C) 1 L____________________________I E"k vm�"-"' IIVt1YNYBBBt(UMTS ID:NYNYU1501yNYL0a501 Ca1c. No.: 25736-415-A3C-EF-00100 Attachment A Rev. 002 Sheet 7 of 7 LTE Revllon- V03 ft•p—d C-ft"th.-3-wir C WARR: 113112013 ANTENNA i X x x x x x x x x x x x x x x x X x x x X x x x X x x x MIRPHI S-It.c �wc un Iw wn—a< uMlseso rgg–.j 4 GBI,tBW .......«._..... Imllseso V GsMlM •– -- ----- ------ R. 1 --------------------- -------------- 1900 850 UMTS U�,JTS •of Radlo:2 0 o Redid:1 &WBCA ii #of WOC:0 1 11 FIBER NODE S I II Cbinst 0 3(UMTS-Sct—A,B&C) Cbi..t 9 1(GSM1900-Sd—AB&C) ii CbWt 0 2(GSNM50-Sd—AB&C) I ----------------------------' ssu Ewe*— Calc. No.: 25736-415-A3C-EF-00100 Attachment B Rev. 002 Sheet 1 of 5 Qu11" 1tei MultiSery Quadband 8 Port Antenna New Dimensions in Wireless 2x700 MHz,2x85 0MHz,2x1900MHz,2x1710/2170MHz The Quintel MultiSery Quadband 8 Port Antenna with patented QTiItTm technology uniquely Quick Facts: delivers four independent services in a single slim-line antenna.This enables existing antenna- Product M QS6658-2 constrained network sites to be upgraded to add new services such as LTE in both 700&AWS Polarisation: xx bands with the replacement of one antenna. Services: 4 Height: 72.5" The Quintel MulitSery Quadband 8 Port Antenna is an ideal solution for independently optimizing Beam width: 65° multiple services when rapidly introducing new services.Technology agnostic,each band provides flexibility for existing and future technologies such as GSM,CDMA,UMTS,LTE and advanced MIMO implementations. The tilt of each band is controlled independently via internal RET actuators compliant to AISG1.1,AISG2.0 and 3GPP protocols. Providing a total of 4 independent tilts 1x(698-787MHz)+1x(824-894MHz)+1x(1850-199OMHz)+1x(1710/1755,2110/2170MHz). Features Operates over the 700,850,1900&AWS bands,all in one antenna. Dual RET inputs configurable for AISG 1.1/2.0 and 3GPP software via upload. Has variable electrical tilt per frequency band. Provides 8 antenna Ports in a slim-line(12"wide)form factor. Enables independent technology performance optimisation per band. Allows a simple antenna swap out and upgrade to high order MIMO. AISG&3GPP compliant internal remote electrical tilt(RET). rO Operating Frequency 698MHz to 787MHz 824MHz to 894MHz Azimuth 3dB beamwidth' 65.50 640 % Elevation beamwidth' 120 10.50 Gain' 13.OdBi 14.OdBi Polarization ±450 ±450 Electrical down-tilt range 20-100 2°-100 Upper sidelobes(Within 200 above mainbeam)' -18dB -18dB Front to Back Ratio(Co Polar within 20°cone) ZtMB a25dB Interband isolation' a25dB Z250 Intra band isolation 2300 a30dB Return loss(VSWR) 14dB(1.5:1) 14dB(1.5:1) Squint' >±3deg >±3deg Tracking' >±3dB >±2dB Cross Pole discrimination(at 00) >15dB >15dB Power handling(per port) 500 watts 500 watts Passive intermodulation 150dBc(2x 43dBm) 15OdBc(2x 43dBm) i Electrical Characteristics 190OMHz AWS Operating Frequency 185OMHz to 1990MHz 1710-1755/2110-217OMHz Azimuth 3dB beamwidth' 560 59-700 Elevation beamwidth' 5.750 6.30 Gain' 16.5dBi 16-16.4dBi Polarization ±450 ±450 Electrical down-tilt range 2°-70 20-70 Upper sidelobes(Within 200 above mainbeam)' -18dB -18dB Front to Back Ratio(Co Polar within 20°cone) 225dB 2:25dB Inter band isolation' Z28dB t28dB Intra band isolation a28dB 228dB Return loss(VSWR) 14dB(1.5:1) 14dB(1.5:1) Power handling(per port) 300 watts 300 wafts Squint' >±3deg >±3deg Tracking' >±3dB >±2dB Cross Pole discrimination(at 0 ) >18dB >14dB Passive intermodulation 150dBc(2x 43dBm) 150dBc(2x 43dBm) 'Typical Performance across frequency and downfilt. Quintel Product Datasheet QS6658-2(Quadband LTE700-AWS 72'65deg)June 2012(Rev 2 5) Calc. No.: 25736-415-A3C-EF-00100 Attachment B Rev. 002 Sheet 2 of 5 Quintel MultiSery Quadband 8 Port Antenna "Iew Dimensions in vVi e'lass 2x700MHZ,2x850MHz,2x1900MHZ,2x1710/2170MHz AISG Standards V1.1,V 2.0 and 3GPP AISG Data rate 9.6 kbs *•m- No of RETs 4 internal y Connector type IEC 60130-9(Ed 3.0) 'r MTBF 36,000 Operational moves FCC Part 15, EN 60950-1 (v2001), S a ce c Type approvals EN61000-4-5(Lightning protection) w Width 12 inches � Depth 9 in V Height 72.5 inches Weightexcl mounting brackets 79lbs(36 kg) y> No.of connectors 8(2 per operating band) Connector type 7/16 DIN female Long neck Max Operational wind speed 150mph(67m/s) Wind load @ Operational wind Frontal 955N(214lbs) Side 587N(132lbs) Operating temperature -40°C to+65°C All specifications are subject to change without notice. Please contact your Quintel representative for complete details About Quintel Quintel is a leading innovator in the design, development, and delivery of network-efficient antenna solutions for wireless operators worldwide. The company's products enable global wireless operators to independently deploy and optimize multiple air interfaces or services on a single standard antenna platform. Quintel is the only antenna maker whose products can increase a wireless network's capacity and provide additional services, without increasing the number or size of antennas. Our core technologies originated in the United Kingdom's Ministry of Defence, and is now deployed throughout the world. Quintel is headquartered in Rochester, New York with engineering and sales offices in Mountain View, California, and Bicester, UK with additional offices throughout North America, Europe and Asia. More information about Quintel is available at www.quintelsolutions.com. Americas EMEA India Regional Office T: +1 (650)353-4240 T: +44(0)1869 362 960 T: +91 22 40907040 F: +1 (650)472-9186 F: +44(0)1869 248 205 F: +91 22 40907070 info @quintelsolutions.com info @quintelsolutions.com info @quintelsolutions.com Technical Support(Americas) Technical Support(EMEA) Technical Support(India) T: +1 (602)692-8600 T: +44(0)1869 362 960 T: +91 (0)22 4090 7040 support@quintelsolutions.com support@quintelsolutions.com support@quintelsolutions.com www.ciuintelsolutions.com AISGYI For general company information, please email: info @qulntelsolutions.com Member THIS DOCUMENT PROVIDES A GENERAL DESCRIPTION OF THE PRODUCT AND SHALL NOT FORM PART OF ANY CONTRACT. ©2012 Quintel Technology Limited.All rights reserved.Quintel and the Quintel logo are registered trademarks Quintel Technology Limited.The AISG logo is a trademark of AISG Limited.All other trademarks are the property of their respective owners. Quintel Product Datasheet QS6658-2(Quadband LTE700-AWS 72'65deg)June 2012(Rev2 5) Calc. No.: 25736-415-A=-EF-00100 Attachment B Rev. 002 Sheet 3 of 5 -I riH c� w SIZE AND WEIGHT TABLE RRH WIDTH DEPTH HEIGHT W/O CABLE WEIGHT MANAGEMENT COVER W/O BRACKET RRH 700 MHz 12.2" 10.8" 21" 51 LBS. 2X40 (80W) RRH AWS 1, 43 LBS. 2X40 (80W) 12 9 25' (W/O SOLAR SHIELD) NOTE: DIMENSIONS INCLUDE MOUNTING BRACKET, SOLAR SHIELD AND CONNECTORS. MINIMUM CLEARANCE TABLE RRH CABINET CLEARANCES COMMENTS INCHES FRONT 36" INSTALLATION ACCESS REAR 2" ZERO REAR CLEARANCE IS ALLOWED USING SUPPLIED MOUNTING BRACKETS RIGHT 4" AIR FLOW LEFT 4" AIR FLOW TOP 12" AIR FLOW BOTTOM 12" CONDUIT ROUTING ALCATEL-LUCENT 9442 REMOTE RADIO HEAD (RRH) DETAIL 1104 NTS — AT&T MOBILITY SCALE.NTS ALCATEL-LUCENT 9442 DETAIL No. REV. .� REMOTE RADIO HEAD (RRH) 1104 0 HOC, NO. 25471-000—A3—EF-00001 Calc. No.: 25736-415-A3C-EF-00100 Attachment B Rev. 002 Sheet 4 of 5 DC6-48-60- 18-8 F N DC Surge Suppression Solution The DC6-48-60-18 is a dual chambered, DC surge suppression system for use in multi-circuit, Distributed Antenna Systems.The system will protect up to 6 Remote Radio Heads from voltage surges and lightning, and connect up to 18 fiber pairs. The system is enclosed in a NEMA 4 rated, waterproof enclosure. FEATURES • Protects up to 6 Remote Radio Heads, each with its own protection circuit. • Flexible design allows for installation at the top of a tower for Remote Radio Head protection. • Includes fiber connections for up to 18 pairs of fiber. • LED indicators on individual circuits provide visual indication of suppressor status. • Form'C'relays allow for remote monitoring of the suppressor status. • Patented Strikesorb technology provides over 60 kA of surge current capacity per circuit. • Strikesorb suppression modules are fully recognized to UL 1449-3rd Edition Safety Standard, meeting all intermediate and high current fault requirements to facilitate use in OEM applications. • Raycap recommends that DC protection system be installed within 2 meters or 6 feet of the radio. • Dome design is lightweight and aerodynamic providing maximum flexibility for installation on top of towers. 1 ft&Tin) s 0 246m 71 123.50) ! r/ spa w� a "'hone 208.777.1166 Toll Free 800.890.2569 Fax 208.777.4466 www.rayr-apsurgeprotection.com Calc. No.: 25736-415-A310-EF-00100 Attachment B Rev. 002 Sheet 5 of 5 DC6-48-60- 18-8 F DC Power Surge Protection Electrical Specifications Model Number DC6-48-60-18-8F y* /y Nominal Discharge Current(1„) 20 kA 8/20 ps Maximum Continuous Operating Voltage(U.) 75 VDC Mechanical Spocifications e. 43� &�: y/�%�/ � 5'` i&S� �,!'f e•�, 3a Jq�^�5"i aM': �� -c` 4 -/ 'S. , x�ll: .../✓F z„d$, �. E t ale.>. ..;4, 9 'f .�?..-,,r Suppression Connection Method Compression lug,#2414 AWG Copper,#2412 Aluminum ANP Environmental Rating IP 68,7m 72hrs 011 ml Storage Temperature -70°C to+80°C i 011, Resistance to Aggressive Materials CEI IEC 61073-2 including acids and bases 1112"1 r Weight 20 Ibs without Mounting Bracket STANDARDS Ctl` Strikesorb modules are compliant to the following Surge Protection Device (SPD) Standards: -ANSI/UL 1449 - 3rd Edition - IEEE C62.41 - NEMA LS-1, IEC 61643-1:2005 2nd Edition:2005 - IEC 61643-12 - EN 61643-11:2002 (including A11:2007) QN17.T.1 6 TOV GS-07F-0435V Ct"ified to Ray�s+l�p t50 90(1112M G02-00-068 REV 050610 Raycap,15?c. 806 W.Clearwater Loop • Post Falls - Idaho - 83854 • USA Pr one 208.777.1166- Till Free 800.890.2569•Fax 208.777.4466•www.raycapsurgeprotection.com Cale. No.: 25736-415-A3C-EF-00100 Attachment C Rev. 002 Sheet 1 of 2 V��J CABLES RDUIED Yp _ _ MO A NEW COQUAL ANTE)"CABLES"MEO UP ON ®NTENNA •A• I"^CCISI D MOLE ® NQOUGN CEUM IN UKW*T TTpoLDgI UMST FL TO EITISTNLG "' EDSTRLO FIRST FLOOR P00E BELOW STORAGE EDSTNLO NIOWLL.M EIWINIG LOLNEAS TO BE ROO /BOOR SroRAf:E W AT&T LOWER STEECKCREIN' NEW MAXAL • ROOM ABOVE s�yuENT AREA ABOVE O SNICIUART ANLENLM CABLES ��- 'RENT MAMA �r _ MG ROUTED UP FROM PANELS.T».of(3). _ LOWER STEEPLE SEE DETAIL x.R15/� 0 BELOW_ TO NEW p/E IOM UNL (.y+__ +_� -�-._EDSTNG EXISTING STATUES, _�_ 70 WI SK MOUNTED E PARABOLIC ANIENW V D M.OF(3) EMNG TOM FACE OF THRIFT WORSHIP UPPCR STEEPLE CONTRACTOR TO RELOCATE EXITING STORE—>> �y LEA_� App Tp ACOOIpLpMIE P097101sIC Red Lines L ExISTNQ AOCESS r ®Ln SECRET t• W NEW PARAeOM ANTENNA WITCH TO STEEPLE / 3 AMIDINAS CONTRACTOR TO PROVIDE CONiNUOS WD. Date:oE-o t-o y ].s ABOVE S•�ej BIMONG KIWEEN FLOOR JOISTS WORN LATCHED N iTne:.[s(N«rCJ�c.•L•.,e..V DASHED LIVE NIRCATES AREA AND SOLD BLOCKING AT BEARING POINTS. SBA Network services �HOOD PAW'ROOF96 MEMBRANE AS RWO O FROM CEERLG ABOVE AN1,01" SIAM FROM�M ( FIMB STAIRS I'RaN BI EVENT ._......... �._ _"_..-.- ....._.... ..._... Qt PLAN ...... GA _ _ c IF r MSBAM PLAN FUIST FLOOR PLAN NEW SECTOR 9, IN IIDRLLS AS REOIMED. </ >.ANTENNA CABLE ROUTING PLANS __._. A �'a ._..... .. /x� ...... ._.. TLRS SHEEP IS 1T•x BT•.REM TO A."CEMT MPLC SCNE. in AMA$M.SECURED tsasEllB ro OEUVEp ANTENNA TIeDLLON LOUVER SRTN LAG BOLTS. 7• 1 ROUGH OPEIlIO JJ 7sAE OF I.OUVQ REPlACO1DR. s {• _ LocUM $71.10 TRIERS Y-7 1/x• 7'-1 /{' - L 1 T. MOM -AmVWLECi' f A NEW INIZED I/x• PNIT091013 ANGLE sEeIREn ro s e'St{}17/x'A710LE WAIN 7/s•aDMeRtats WDO, VLF. NEW LAW LINK GALWAZED =Ml1lIRN M-BOLT,M. PWIP36-W SEE OET.LANFENM% 110011 FIVIAMING NOW M.OF({ Y' LDUMEn FRW COJ16. B I MN HM SON FOR DSISG Weusi KAS01R OF CIMDIT M Y.F. 1F. Alf ANIMS4 WAMPMOO i. a LEW 2- e•O.D. tDIRIETI fArtl.i M. 6�L 33// T,NSZCO STEEL d I7Pf, BEE iDTE M E7], • llsf-0[fill M OOAEE NEW w 101AVE11 PANELS.TIP 1 1 Isnmff MAW zw(3).SEE NOTE 7M5 INTERIM TOE OF 7/Bb COARML MlLEMW ATSW Exam FALRED LI1sSTRlIFµ�ON® O BRAD LOCAROM WNW 9 L FAi EMIOST[�RD _T /. _ .... /1TYP�iaL$�.TIDN 0 LDGIIDN IIEC�NN!PLO m /F�ANTENNA MOUNTING DETAILS WOOD fpAYEAM L i�71IPICAtlLEVaT10N caNRELtTall elsE9NStBLt Felt �°' — �f+�u. A9N L/l�;IR-�v /DT arlaWp PDLI CLAMr. a T7erBSAkNr OMEANELSLwcts. g PARABOUC ANTENNA MOUMING D Cyr ANTE NA NDIRma OVAL. A Ff�j SEE DETAL x THIS WEL 16LA"'° AT&T .Wrr " _— ATILT WIRELESS SERVICES WILLIW 401 AM F.COLLINiAIA pg00/ A .AAr �. A MENTAL RIMY 1 N _ ARCHITECTURAL OCiAIS FISI(RS ISINp,111'11s3T A1iT W � xu{s xot A-3 T t Calc. No.:25736-415-A3C-EF-00100 Attachment C Rev.002 Sheet 2 of 2 GENERAL NOTES g EXISnNa OP S DINT 1. �ri E KMPOSE OF CONSTRUCTION DRAWING. THE FOLLOWING DUINNIONS SMALL € TO REMAIN CONTRACTOR-BECHTEL ¢DIy SLBWNTPACMR-aflE7AL CONTMCIOR(OOIbTRUCTIOx M 6 OEM ORIGINAL-ORn9AL EQUIPMENrt�MNNF�ACTURER AT117 a T+ROPOIED Ors uNr!ra!W t/Y tout E IIOUIm OI BBII FROM ANTE tAS x. STOlt 7o THE SUBMISSION WITH OF IRIS,THE MXrK AND TTRA ONn 9WL ASN MALE CELL WIMI 9EPAM710N iTOY ANENWB) BITE TO MPUMME3 INSH THE N THE CONSTRUCTION AND TO CONFIRM THAT DIS THE DISCREPANCY CAN (SEE DEAAL ta24/ACO FOUND SHAM91ED AS BROUGHT ON THE CNRION C11C TRACTOR. NCI OISpEPINLY T� FOUND SNNL BE 6ROUIWIT 1D THE AllFN110N OF CONTRACTOR. E a. ALL MATERIALS FURNISHED AND MSIAL ED SNAIL BE IN sTRLCT ACCORDANCE WITH NL € APPLICABLE CODES,REGU ATIORL AND ORDINANCES.SUBCONTRACTOR SMALL ISSUE ALL e APPROPRIATE MTIClUi AND COMPLY WITH ALL LAWS,ORDINANCES.RUNES.MOMATIONL AND $, LAA FUL ORDERS OF ANY PUBLIC AUTHORITY REGARDING THE PERFORMANCE OF THE WORN. $ 4. ALL WORK CASED OUT SMALL COMPLY WITH ALL APPLICABLE MUNICIPAL AND UTILITY 2E COMPANY SPECIFICATIONS AND LOCAL MOSDIC11OAL COMER ORDINANCES AND APPUGNIE R REQUUTIONS. €p 5. UNLESS NOTED OTHERWISE THE WARM SMALL INCLUDE FURNISHING MATERVL4,EQUIPMENT. G IPPLRIENIMM=NO LIBOR NECESSARY TO COMPLETE ALL NsrALATKMS AS INDICATED ON THE DRAWINGS. 6. THE sLSCONIRACIOR SMALL INSTAL AU.EQUIPMENT AND MATENALS IN ACCORDANCE WITH S EXISMC CHURCH MANUFACTU EWS RECOMMENDATIONS UNLESS SPEQFlC1LLr STATED OTHERWISE BIAlDN10 7. A THE SPECIFIED EQUIPMENT CANNOT BE INSTALLED AS SHOWN ON THESE DRAWWUS,THE 6 -\ CONTRACTOR SIWL PROPOSE AN ALTERNATIVE MSOIlAl7011 FOR APPItOVIL BY THE EXISTING ATRO EQUIPMENT ROOM IN BASEMENT e. SUBCONTRACTOR CB 911IAS SHOWN N ON ACTUAL POWER.CG UN COHDIND POWER LAN T1 CABLES, GROUNDING CALIFS AS SIIOMI ON THE POWER,GROIRIDHG NO Tf.to PLAN oRA61111G. EXISTING SIEFPIE > 9NNL UIIN2E E)04TM0 TRAYS AND/OR M ADD NEW TRAYS AS ABM ROUT TRO/�9 AP Bpi'CO T WDN THE CONTRACTOR $ Ay 9. THE SUBCONTRACTOR SMALL PROTECT UOSIMRi UPROVU04M MOMENTS,CURBS. B LI LANDSCAPING AND SMUCRRES.ANY DAMAGED PAT SHALL BE REPAIRED AT SUBCONTRACTOR'S EXPENSE TO THE SATISFACTION OF OWNER. HOLE 10. SUBCONTRACTOR SMALL LEANLY AND PROPERLY DISPOSE OF ALL SCRAP MATIRALS SUCH LTE ANTENNA AYSRMNS SHOWN ARE PRELBWARY AS COAXIAL CABLES AND OILER IIE/IS REMOVED FROM THE EXISTING FACT .ANTENNAS 1i AND MAY NOT REFLECT FINAL RF DESIGN.IBM 10SM ST IEMWED SKILL BE RETURNED To THE OWNEAY DESIGNATED LOCATION. S M LATEST OF DATA SHEET FOR FUAL LTE ANTENNA SPET2FIGT101S,ALMUTHIL TLM EM 11, SUSCONIRICTOR MOLL LEAVE PROESES IN CLEAN CONDITION, 1 Flu SCI.E 1/e'-1•-0• 1L ALL CONCRETE REPAIR WORK SMALL BE DONE IN ACCORDANCE WITH MERMAN CONCRETE ANTENNA ORIFNTATION/A2WUMS SMALL BE FIELD VERIFIED. F 9 . u rt INSTITUTE(�)Wt. z.EOUM'MFM/ARENNAS BY OTHERS HOT SHOWN FOR CLAIM `C'/ ROOF PLAIT t ® ta. ANY NEW CONCRETE MEWED FOR THE CONSTRUCTION SMALL HAYS 400D PSI STRENGTH AT 3.AL NEW ANTENNAS!RRWS TO BE PANTED TO MATCH EXISTING ANTENNAS. SGyE 1/B'.1'-0' Ao1 MALT SCAE 1/16'-1•-o' 2e DAYS UNLESS OTHIENIesE SPECIFIED ILL CONCRETING WORK SMALL BE DOE IN ACCORDANCE WITH AO ate CODE REONNEMEKM LINE 8 N CABLE ROOF� 14. AU.STRUCTURAL STEEL WOW SMALL BE DONE IN ACCOIIO,WCE WITH AMC 4PECI1CATKINS. A6 EXISTING LAND LNNK PARABOLIC ANTENNA 15 CONSIRIICIKIN SMALL COMPLY WITH 3PEGFlGTI N 25736-OW-3PS-A00Z-00001, sRAP(1)MC ANIOIA FOR NEW GENERAL CONSTRICTION SERWCES OUMEL AM INT06A(ECRR N 16. STlWNM/CNR SMALL VERIFY ALL OWING DIMENSIONS AND COmoinomS POOR TO (!E OEM•L!a/LOS) COMMENCING ANY WORK.ALL DYE1190113 OF E ISINQ CONSTRICTION SHOWN ON THE ISTALi PROPOSED wan DRAWINGS MAST BE VERFIED.SUBCONTRACTOR SMALL NOTIFY THE CONTRACTOR OF ANY SWAP(1)Vr ANNTEHA FOR NEW II ygR11m�OII w—pcm WITH DISCREPANCIES PRIOR TO(WIDENING LATERAL OR PROCEEDING WITH CONSTRUCTION. (SM DETM ATILT AnFMA(SECTOR C) PIIOPW[D ATE T BST(SLT011 N 17. THE EISINO CELL SIZE M N FULL WMEROAL OPERATMR, ANY CONSTRwnow WON (BEE DETAL 243/AD» II (SEE DEDEL t/AO4> M Q II EXISTING EQUIPMENT MUST E COORDINATED �WNTRAIMOR.ALSO,WORK MAY WORK ON INSTAL(2)PROPOSED RRNS IIOLMm I II �L NppgEN A IT.AN APPROPRIATE MAINTENANCE WINDOW USUALLY N lAR TRARIC PERMS ON UMSTIW/T WITH PIgP09ED PIPE COST ON WITH MAW €. (SECTOR C)(SEE METAL 1/AO4) IL _ JI (SWAP B)(SEE DEAL 1 AIDS) 1K. SINCE THE CELL SIZE MAY IE ACINE.ALL SAFETY PRECAUTIONS MUST BE THEN WHEN WORKING AROUND MOIL LLYES OF EECIPOMAGNEM RAONTI N. EQUIPMENT SHOULD BE OIM4 AT-AINIDIM(lGTOR s) DANCER PERSONAL IF EXPOSURE MONITORS AM REOUNUM WORN TO ALERT OF ANY (SEE DET/L 2!S/ADS) DNIOEROUS EO(POSINE LEVELS. R� (N(aasEETEENlµt)M�LABBB�B))FOR MMQUUNTING FULL SCAE 7/6'-1'-O' UPPER STEEPLE ANTENNA PLAT z g ry¢DEaWL ttts/A0� r 9®IT DETAIL 1 SCARE Oro'-1'-O• 1 SCALE:N.T.S. INNS SCALE 3/te•-r-0' BECHTEL ASSOCIATES SITE NAME FISHERS ISLAND p ®SfAf PROFESSIONAL CORPORATOR ® at&t A MY OF BECHTEL CORPORATION ORIENTAL AVENUE AND EMKK ABAENUE ROOF ANTI PLAN! 5275 IIESTVIEW DIANE 1 lW-�li H..Iwv r s AC FREOERCK,MD 21703-SM USA � NT�M A .'O AWOW w aK .� — r 25736-415 T3-INYNRIVO301-ADM A Calc. No.: 25736-415-A3C-EF-00100 Attachment D Rev. 002 Sheet 1 of 3 f 1. Sector Alpha � r 2. Sector Beta Calc. No.: 25736-415-A3C-EF-00100 Attachment D Rev. 002 Sheet 2 of 3 i 3. Sector Gamma Y q3 � aln 4. Picture showing top connection Cale. No.: 25736-415-A3C-EF-00100 Attachment D Rev. 002 Sheet 3 of 3 �1 r y° G 5. Picture Showing Bottom Connection Calc. No.: 25736-415-A3C-EF-00100 Attachment E Rev. 002 Sheet 1 of 12 Job No Sheet No Rev 1 Software licensed to Bechtel Corporation Part Job Title Ref By Date12-Mar-13 Chd Client File NYNYNY0801.std IDIt8mI 22-Mar-2013 10:39 i I i i i i 3. i i i I i i.oxes I Node Numbers Print Vnre/Dale:22/03/201310:45 STAAD.Pro V8i(SELECTseries 1)20.07.06.35 Print Run 1 of 5 Calc. No.:25736-415-A3C-EF-00100 Attachment E Rev. 002 Sheet 2 of 12 Job No Sheet No Rev 2 Software licensed to Bechtel Corporation Part Job Title Ref By Date12-Mar-13 Chd Client File NYNYNY0801.std Date/Time 22-Mar-2013 10:39 ,y iI I i !, 3 1 i I 2 i i Load d 1 r Beam Numbers Print Time/Date:22/03/2013 10:45 STAAD.Pro V8i(SELECTSeries 1)20.07.06.35 Print Run 2 of 5 Calc. No.:25736-415-A3C-EF-00100 Attachment E Rev. 002 Sheet 3 of 12 Job No Sheet No Rev 3 Software licensed to Bechtel Corporation Part Job Title Ref By DaIe12-Mar-13 Chd Client Pile NYNYNY0801.Std Daterth"a 22-Mar-2013 10:39 i i I 3.3 ft i 2.1 ft i I I 2.1 ft �x Y Ltxac9 1 Dimensions Print Time/Date:22/03/2013 10:45 STAAD.Pro V81(SELECTseries 1)20.07.06.35 Print Run 3 of 5 Calc. No.: 25736-415-A3C-EF-00100 Attachment E Rev. 002 Sheet 4 of 12 t Job No Sheet Na Rev ' 4 Software licensed to Bechtel Corporation Part Job Title Ref By Date12-Mar-13 Chd Client File NYNYNY0801.Std Datemme 22-Mar-2013 10:39 Y Load 1 s`,SELF Y) J� Dead Load Print Time/Dale:22103/2013 10:45 STAAD.Pro V8i(SELECTseries 1)20.07.06.35 Print Run 4 of 5 Calc. No.: 25736-415-A3C-EF-00100 Attachment E Rev. 002 Sheet 5 of 12 Job No Sheet No Rev Soilware licensed to Bechtel Corporation Part Job Title Ref By Date12-Mar-13 Chd Client File NYNYNY0801.std Daternme 22-Mar-2013 10:39 -51.000 lb 51.000 lb Load 2 Live Load Print Time/Date:22/03/2013 10:45 STAAD.Pro V8i(SELECTseries 1)20.07.06.35 Print Run 5 at 5 Calc. No.: 25736-415-A3C-EF-00100 Attachment E Rev. 002 Sheet 6 of 12 Friday, March 22, 2013, 01:51 PM PAGE NO. 1 ++++++++++++++++++++++++++++++++++++++++++++++++++++ + + * STAAD.Pro V8i SELECTseriesl * Version 20.07.06.35 * Proprietary Program of * Bentley Systems, Inc. * Date= MAR 22, 2013 * Time= 12:12:46 + + * USER ID: Bechtel Corporation ++++++++++++++++++++++++++++++++++++++++++++++++++++ 1. STAAD SPACE INPUT FILE: NYNYNY0801.STD 2. START JOB INFORMATION 3. ENGINEER DATE 12-MAR-13 4. END JOB INFORMATION 5. INPUT WIDTH 79 6. UNIT FEET POUND 7. JOINT COORDINATES 8. 1 0 0 0; 2 0 2.1 0; 3 0 5.2 0; 4 0 7.5 0 9. MEMBER INCIDENCES 10. 1 1 2; 2 2 3; 3 3 4 11. DEFINE MATERIAL START 12. ISOTROPIC STEEL 13. E 4.176E+009 14. POISSON 0.3 15. DENSITY 489.024 16. ALPHA 6E-006 17. DAMP 0.03 18. END DEFINE MATERIAL 19. MEMBER PROPERTY AMERICAN 20. 1 TO 3 TABLE ST PIPS20 21. CONSTANTS 22. MATERIAL STEEL ALL 23. SUPPORTS 24. 1 4 FIXED BUT MX MZ 25. LOAD 1 LOADTYPE DEAD TITLE DL 26. SELFWEIGHT Y -1 LIST 1 TO 3 27. LOAD 2 LOADTYPE LIVE REDUCIBLE TITLE LL 28. JOINT LOAD 29. *WEIGHT OF RRH 30. 2 3 FY -51 31. LOAD COMB 3 GENERATED AISC GENERAL 2 32. 1 1.0 2 1.0 33. LOAD COMB 4 GENERATED AISC GENERAL 3 34. 1 1.0 2 0.75 35. PERFORM ANALYSIS PRINT STATICS CHECK C:\Users\krdheram\Desktop\0801\NYNYNY0801.an1 Page I of 8 Calc. No.: 25736-415-A=-EF-00100 Attachment E Rev. 002 Sheet 7 of 12 Friday, March 22, 2013, 01:51 PM STAAD SPACE -- PAGE NO. 2 P R O B L E M S T A T I S T I C S ----------------------------------- NUMBER OF JOINTS/MlXBER+ELEMENTS/SUPPORTS = 4/ 3/ 2 SOLVER USED IS THE OUT-OF-CORE BASIC SOLVER ORIGINAL/FINAL BAND-WIDTH= 1/ 1/ 12 DOF TOTAL PRIMARY LOAD CASES = 2, TOTAL DEGREES OF FREEDOM = 16 SIZE OF STIFFNESS MATRIX = 1 DOUBLE KILO-WORDS REQRD/AVAIL. DISK SPACE = 12.0/ 100550.4 MB C:\Users\krdheram\Desktop\0801\NYNYNY080l.anl Page 2 of 8 Calc. No.: 25736-415-A3C-EF-00100 Attachment E Rev. 002 Sheet 8 of 12 Friday, March 22, 2013, 01:51 PM STAAD SPACE -- PAGE NO. 3 STATIC LOAD/REACTION/EQUILIBRIUM SUMMARY FOR CASE NO. 1 LOADTYPE DEAD TITLE DL CENTER OF FORCE BASED ON Y FORCES ONLY (FEET). (FORCES IN NON-GLOBAL DIRECTIONS WILL INVALIDATE RESULTS) X = 0.000000000E+00 Y = 0.375000009E+01 Z = 0.000000000E+00 ***TOTAL APPLIED LOAD ( POUN FEET ) SUMMARY (LOADING 1 ) SUMMATION FORCE-X = 0.00 SUMMATION FORCE-Y = -27.25 SUMMATION FORCE-Z 0.00 SUMMATION OF MOMENTS AROUND THE ORIGIN- MX= 0.0000000E+00 MY= 0.0000000E+00 MZ= 0.0000000E+00 ***TOTAL REACTION LOAD( POUN FEET ) SUMMARY (LOADING 1 ) SUMMATION FORCE-X = 0.00 SUMMATION FORCE-Y = 27.25 SUMMATION FORCE-Z = 0.00 SUMMATION OF MOMENTS AROUND THE ORIGIN- MX= 0.0000000E+00 MY= 0.0000000E+00 MZ= 0.0000000E+00 MAXIMUM DISPLACEMENTS ( INCH /RADIANS) (LOADING 1) MAXIMUMS AT NODE X = 0.00000E+00 0 Y = -8.40334E-06 3 Z = 0.00000E+00 0 RX= 0.00000E+00 0 RY= 0.00000E+00 0 RZ= 0.00000E+00 0 STATIC LOAD/REACTION/EQUILIBRIUM SUMMARY FOR CASE NO. 2 LOADTYPE LIVE REDUCIBLE TITLE LL CENTER OF FORCE BASED ON Y FORCES ONLY (FEET). (FORCES IN NON-GLOBAL DIRECTIONS WILL INVALIDATE RESULTS) X = 0.000000000E+00 Y = 0.365000020E+01 Z = 0.000000000E+00 C:\Users\krdheram\Desktop\0801\NYNYNY0801.an1 Page 3 of 8 Calc. No.: 25736-415-A3C-EF-00100 Attachment E Rev. 002 Sheet 9 of 12 Friday, March 22, 2013, 01:51 PM STAAD SPACE -- PAGE NO. 4 ***TOTAL APPLIED LOAD ( POUN FEET ) SUMMARY (LOADING 2 ) SUMMATION FORCE-X = 0.00 SUMMATION FORCE-Y = -102.00 SUMMATION FORCE-Z = 0.00 SUMMATION OF MOMENTS AROUND THE ORIGIN- MX= 0.0000000E+00 MY= 0.0000000E+00 MZ= 0.0000000E+00 ***TOTAL REACTION LOAD( POUN FEET ) SUMMARY (LOADING 2 ) SUMMATION FORCE-X = 0.00 SUMMATION FORCE-Y = 102.00 SUMMATION FORCE-Z = 0.00 SUMMATION OF MOMENTS AROUND THE ORIGIN- MX= 0.0000000E+00 MY= 0.0000000E+00 MZ= 0.0000000E+00 MAXIMUM DISPLACEMENTS ( INCH /RADIANS) (LOADING 2) MAXIMUMS AT NODE X = 0.00000E+00 0 Y = -4.41529E-05 3 Z = 0.00000E+00 0 RX= 0.00000E+00 0 RY= 0.00000E+00 0 RZ= 0.00000E+00 0 ************ END OF DATA FROM INTERNAL STORAGE ************ 36. PARAMETER 1 37. CODE AISC 38. CHECK CODE ALL C:\Users\krdheram\Desktop\0801\NYNYNY0801.an1 Page 4 of 8 Calc. No.: 25736-415-A3C-EF-00100 Attachment E Rev. 002 Sheet 10 of 12 Friday, March 22, 2013, 01:51 PM STAAD SPACE -- PAGE NO. 5 STAAD.Pro CODE CHECKING - (AISC 9TH EDITION) ALL UNITS ARE - POUN FEET (UNLESS OTHERWISE NOTED) NMNBER TABLE RESULT/ CRITICAL COND/ RATIO/ LOADING/ FX MY NZ LOCATION 1 ST PIPS20 (AISC SECTIONS) PASS AISC- H1-3 0.003 3 65.99 C 0.00 0.00 0.00 2 ST PIPS20 (AISC SECTIONS) PASS AISC- H1-3 0.000 3 7.36 C 0.00 0.00 0.00 3 ST PIPS20 (AISC SECTIONS) PASS AISC- H2-1 0.003 3 63.27 T 0.00 0.00 2.30 39. PRINT SUPPORT REACTION ALL C:\Users\krdheram\Desktop\0801\NYNYNY0801.an1 Page 5 of 8 Calc. No.: 25736-415-A3C-EF-00100 Attachment E Rev. 002 Sheet 11 of 12 Friday, March 22, 2013, 01:51 PM STAAD SPACE -- PAGE NO. 6 SUPPORT REACTIONS -UNIT POUN FEET STRUCTURE TYPE = SPACE ----------------- JOINT LOAD FORCE-R FORCE-Y FORCE-Z MOM-% MOM-Y MOM Z 1 1 0.00 13.63 0.00 0.00 0.00 0.00 2 0.00 52.36 0.00 0.00 0.00 0.00 3 0.00 65.99 0.00 0.00 0.00 0.00 4 0.00 52.90 0.00 0.00 0.00 0.00 4 1 0.00 13.63 0.00 0.00 0.00 0.00 2 0.00 49.64 0.00 0.00 0.00 0.00 3 0.00 63.27 0.00 0.00 0.00 0.00 4 0.00 50.86 0.00 0.00 0.00 0.00 xxxxxxxxxxxxxx END OF LATEST ANALYSIS RESULT ************** 40. UNIT INCHES KIP 41. PARAMETER 2 42. CODE AISC 43. FYLD 35 ALL 44. FINISH *********** END OF THE STAAD.Pro RUN *********** **** DATE= MAR 22,2013 TIME= 12:12:46 **** C:\Users\krdheram\Desktop\0801\NYNYNY0801.an1 Page 6 of 8 Calc. No.: 25736-415-A3C-EF-00100 Attachment E Rev. 002 Sheet 12 of 12 Friday, March 22, 2013, 01:51 PM STAAD SPACE -- PAGE NO. 7 *.xxxxxxxxxxxxxxxxxxxxxxxxxxx**xxxxxxx***xxxxxxxx***xx*xxx*+ * For questions on STAAD.Pro, please contact * Bentley Systems Offices at the following locations * Telephone Web / Email • USA: +1 (714)974-2500 • UK +44(1454)207-000 • SINGAPORE +65 6225-6158 • EUROPE +31 23 5560560 • INDIA +91(033)4006-2021 • JAPAN +81(03)5952-6500 http://www.ctc-g.co.jp • CHINA +86 10 5929 7000 • THAILAND +66(0)2645-1018/19 partha.p @reisoftwareth.com x * Worldwide http://selectservices.bentley.com/en-US/ xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx:*.*xx**xx*.xxxx*xx*****xxxxx C:\Users\krdheram\Desktop\0801\NYNYNY0801.anl Page 7 of 8 Calc. No.:25736-415-A3C-EF-00100 Attachment F Rev. 002 Sheet 1 of 2 C •8 r c'r r , 4AAA3o4. MOVOSEA A30 f MA 80-T Z.1 ELEV A-T It 20 1 s is QEt1 SE A" -010 S.-Tv STEEL- ME, Calc. No.: 25736-415-A3C-EF-00100 Attachment F Rev. 002 Sheet 2 of 2 I i r f-MSTIM G LA(n BOUTS (-T- •2 Vi lw 1 t /90 S U-BOt-T NYNYNY0801 903006201 Market: New York Cell Site Number: NYNYNY0801 Address: Oriental Avenue, Fishers Island, NY 06390 OPTION AND LEASE AGREEMENT THIS OPTION AND LEASE AGREEMENT construction drawings, provided that the construction ("Agreement"), dated as of the date below, is entered into drawings do not deviate from Exhibit 1, that, in the by Our Lady of Grace Roman Catholic Church, a New opinion of Tenant, are necessary in Tenant's sole discretion York Religious Corporation, having a mailing address of to determine the physical condition of the Property, the P.O. Box 425, Fishers Island, NY 06390 (hereinafter environmental history of the Property, Landlord's title to referred to as "Landlord") and CELLULAR the Property and the feasibility or suitability of the Property TELEPHONE COMPANY, a New York partnership, for Tenant's Permitted Use, all at Tenant's expense. d/b/a AT&T WIRELESS, having a mailing address of IS Tenant will not be liable to Landlord or any third party on East Midland Avenue, Paramus, New Jersey 07652 account of any pre-existing defect or condition on or with (hereinafter referred to as "Tenant"). respect to the Property, whether or not such defect or condition is disclosed by Tenant's inspection. BACKGROUND (c) In consideration of Landlord granting Tenant the Option, Tenant hereby agrees to pay Landlord Landlord owns that certain plot, parcel or tract of land, the sum of One Thousand Dollars ' within together with all rights and privileges arising in thirty (30) days of execution of this Agreement. The connection therewith, located at Oriental Avenue, Fishers Option will be for a term of one (1) year (the " Option Island, in the County of Suffolk, State of New York, as Term"). indicated on the Suffolk County Tax Map #1000-009-07- (d) During the Option Term, Tenant may 11 (collectively "Property"). Tenant desires to have a exercise the Option by notifying Landlord in writing. If non-exclusive use of a portion of the Property in Tenant exercises the Option then Landlord leases the connection with its federally licensed communications Premises to the Tenant subject to the terms and conditions business. Landlord desires to grant to Tenant the right to of this Agreement. If Tenant does not exercise the use a non-exclusive portion of the Property in accordance Option during the Option Term, this Agreement will with this Agreement. terminate and the parties will have no further liability to The parties agree as follows: each other. 1. OPTION TO LEASE. 2. PERMITTED USE. Tenant may use the (a) Landlord hereby grants Tenant an Premises for the transmission and reception of option (the "Option") to lease a portion of the Property communications signals and the installation, maintenance, consisting of (a) a room/cabinet space of approximately operation, repair and replacement of its communication 150 square feet and (b) space in the structure and such fixtures and related equipment, cables, accessories and easements as are necessary for the antennas and initial improvements, which may include a suitable internal installation as described on attached Exhibit 1 support structure, associated antennas and any other items (collectively, "Premises"). necessary to the successful and secure use of the Premises (b) During the Option period and during the (collectively the "Communication Facility); such use term of this Agreement, Tenant and its agents, engineers, includes the right to test, survey and review title on the surveyors and other representatives will have the right to Property. If Tenant needs to construct an internal support enter upon the Property to inspect, examine, conduct soil structure, Tenant shall first obtain Landlord's prior borings, drainage testing, material sampling, and other ' approval. Said approval shall not be unreasonably geological or engineering tests or studies of the Property withheld, conditioned, or delayed. If Exhibit 1 includes (collectively the "Tests"), to apply for and obtain licenses, drawings of the initial installation of the Communication permits, approvals, or other relief required of or deemed Facility, Landlord's execution of this Agreement will necessary or appropriate at Tenant's sole discretion for its signify Landlord's approval of Exhibit 1. Tenant has the non-exclusive use of the Premises and include without right to make Property improvements, alterations or limitation applications for zoning variances, zoning additions ("Tenant Changes") appropriate for Tenant's ordinances, amendments, special use permits, and use, provided Tenant first obtains Landlord's approval. construction permits (collectively referred to as Tenant agrees to comply with all applicable governmental "Governmental Approvals"), and otherwise to do those laws, rules, statutes and regulations, relating to its use of things on or off the Property, as described on the the Communication Facility on the Property. Tenant has rev.9/24/2002 Option Structure !..,case the right to modify, supplement, replace, upgrade, zoning variances, zoning ordinances, amendments, expand the equipment, or relocate the Communication special use permits, and construction permits (collectively Facility within the Premises at any time during the term referred to as "Governmental Approvals"). Landlord of this Agreement. Tenant shall not increase the number authorizes Tenant to prepare, execute and file all required of antennas without Landlord's prior consent. Such applications to obtain Governmental Approvals for consent shall not be unreasonably withheld, conditioned Tenant's Permitted Use under this Agreement and agrees or delayed. to reasonably assist Tenant with such applications. The 3. TERM. (a) The initial lease term will be ten cost of obtaining any governmental approvals shall be at (10) years ("Initial Term"), commencing upon the Tenant's sole cost and expense. Commencement Date, as defined below. The Initial (b) Tenant has the right, at its sole cost and Term will terminate on the last day of the month in which expense, to obtain a title report or commitment for a the tenth annual anniversary of the Commencement Date leasehold title policy from a title insurance company of its occurs. choice and to have the Property surveyed by a surveyor (b) This Agreement will automatically of Tenant's choice. renew for two (2) additional five (5) year Term(s) (each (c) Tenant may also obtain, at Tenant's sole five (5) year term shall be defined as the "Extension cost and expense, soil boring, percolation, engineering Term"), upon the same terms and conditions unless the procedures, environmental investigation or other tests or Tenant notifies the Landlord in writing of Tenant's reports (collectively the "Tests") on, over, and under the intention not to renew this Agreement at least ninety (90) Property, necessary to determine if the Tenant's use of days prior to the expiration of the existing Term. the Premises will be compatible with, Tenant's (c) If Tenant remains in possession of the engineering specifications, system, design, operations or Premises after the termination or expiration of this Governmental Approvals. Agreement then Tenant will be deemed to be occupying the Premises on a month to month basis (the "Holdover 6. TERMINATION. This Agreement may be Term"), subject to the terms and conditions of this terminated, without penalty or further liability, as Agreement. follows: (d) The Initial Term, the Extension Term (a) by either party on thirty (30) days prior and the Holdover Term are collectively referred to as the written notice, if the other party remains in default under Term. ("Term"). Paragraph 14 of this Agreement after the applicable cure periods; 4. RENT. (a) Commencing on the date that (b) by Tenant upon written notice to Tenant commences construction (the "Commencement Landlord, if Tenant is unable to obtain, or maintain, any Date"), Tenant will a the Landlord a monthly rental required approval(s) or the issuance of a license or permit payment of by any agency, board, court or other governmental ("Rent"), at the address set forth above, on or before the authority necessary for the construction or operation of 5' day of each calendar month in advance. Rent will be the Communication Facility as now and hereafter prorated for any partial month, intended by Tenant or if Tenant determines in its sole (b) Beginning with year two of the Initial discretion that the cost of obtaining or retaining the same Term, and each year thereafter, including any Extension is commercially unreasonable; Terms the monthly Rent will increase by (c) by Tenant on sixty (60) days written over the previous year's Rent. notice for any reason, so long as Tenant pays Landlord a (c) Tenant agrees to pay LandIord's termination fee equal to nine (9) months Rent, at the reasonable legal fees for the revie f_ih, A reement current rate; provided , however, that no such termination and in an amount not to exceed fee will be payable on account of a termination of this upon reasonable proof of same. - Agreement by Tenant under any one or more of paragraphs 6(a), 6(b), 7, 17, 18 or 19 of this Agreement. 5. APPROVALS. (a) Landlord agrees that Tenant's ability to use the Premises is contingent upon the 7. INTERFERENCE. (a) Where there are suitability of the Premises for Tenant's Permitted Use and existing radio frequency user(s) on the Landlord's Tenant's ability to obtain all governmental licenses, Property, the Landlord will provide Tenant with a list of permits, approvals or other relief required of or deemed all existing radio frequency user(s) and their frequencies necessary or appropriate by Tenant for its use of the on the Property to allow Tenant to evaluate the potential Premises, including without limitation applications for for interference. Tenant warrants that its use of the 2 rev. 9/24/2002 Option Structure Lease Premises will not interfere with existing radio frequency user(s) on the Property so disclosed by Landlord, as long (b) Landlord agrees to indemnify, defend as the existing radio frequency user(s) operate and and hold Tenant harmless from and against any and all continue to operate within their respective frequencies and injury, loss, damage or liability (or any claims in respect in accordance with all applicable laws and regulations. of the foregoing), costs or expenses (including reasonable (b) Landlord will not grant, after the date attorneys' fees and court costs) arising directly from the of this Agreement, a lease, license or any other right to actions or failure to act of Landlord or its employees or any third party for use of the Property, if such use may in agents, resulting in Landlord's breach of any provision of any way adversely affect or interfere with Tenant's this Agreement, except to the extent attributable to the Communication Facility. Landlord will notify Tenant negligent or intentional act or omission of Tenant, its prior to granting any third party the right to install and employees, agents or independent contractors. operate communications equipment on the Property. (c) Notwithstanding anything to the Nothing contained herein will restrict Tenant nor its contrary herein contained in this Agreement, in no event successors and assigns from installing and modifying its shall the scope of the indemnity provisions set forth in communications equipment. this section 8 to be deemed to be limited to available (c) Landlord will not materially change or insurance proceeds of any policy of insurance required to alter its use, nor will Landlord permit its employees, be maintained pursuant to the terms of this Lease or tenants, licensees, invitees or agents to materially change otherwise. or alter the use of any portion of the Property in any way which interferes with the operations of Tenant or the 9. WARRANTIES. (a) Tenant and Landlord each rights of Tenant under this Agreement. Landlord will acknowledge and represent that it is duly organized, cause such interference to cease within twenty-four (24) validly existing and in good standing and has the right, hours after receipt of notice of interference from Tenant. power and authority to enter into this Agreement and bind In the event any such interference does not cease within itself hereto through the party set forth as signatory for the aforementioned cure period then the parties the party below. acknowledge that Tenant will suffer irreparable injury, (b) Landlord represents and warrants that: and therefore, Tenant will have the right, in addition to (i) Landlord solely owns the Property as a legal lot in fee any other rights that it may have at law or in equity, for simple, or controls the Property by lease or license; (ii) Landlord's breach of this Agreement, to elect to enjoin the Property is not encumbered by any liens, restrictions, such interference or to terminate the Agreement upon mortgages, covenants, conditions, easements, leases, or notice to Landlord. any other agreements of record or not of record, which (d) The installation and maintenance of the would adversely affect Tenant's Permitted Use and Communication Facility will not interfere with the enjoyment of the Premises under this Agreement; (iii) as Landlord's existing emergency equipment or operations long as Tenant is not in default then Landlord grants to within the Property. In the event that Tenant's Tenant sole, actual, quiet and peaceful use, enjoyment installations interfere with the Landlord's equipment or and possession of the Premises; (iv) Landlord's execution operations, Tenant will immediately cease such and performance of this Agreement will not violate any interference, after notice thereof until it is able to resolve Laws, ordinances, covenants or the provisions of any the problem. If the interference cannot be resolved, either mortgage, lease or other agreement binding on the party will be entitled to terminate this Agreement and Landlord; and (v) if the Property is or becomes render it null and void. encumbered by a deed to secure a debt, mortgage or other security interest, Landlord will use best efforts to provide 8. INDEMNIFICATION. (a) Tenant agrees to promptly to Tenant a mutually agreeable Subordination, indemnify, defend and hold Landlord harmless from and Non-Disturbance and Attornment Agreement. against any and all injury, loss, damage or liability (or - (c) Tenant warrants that no part of the Communication any claims in respect of the foregoing), costs or expenses Facility will be visible from the street and that the (including reasonable attorneys' fees and court costs) proposed shutters in the church steeple wild be of the arising directly from the installation, use, maintenance, same appearance and color as the existing shutters. i repair, removal, or restoration of the Communication LL Facility or Tenant's breach of any provision of this 10. ENVIRONMENTAL. (a) Landlord and Agreement, except to the extent attributable to the Tenant agree that each will be responsible for compliance negligent or intentional act or omission of Landlord, its with any and all environmental and industrial hygiene employees, agents or independent contractors. laws, including any regulations, guidelines, standards, or 3 rev.9/24/2002 Option Structure Lease f policies of any governmental authorities regulating or Tenant will be and remain Tenant's personal property imposing standards of liability or standards of conduct and, at Tenant's option, may be removed by Tenant at with regard to any environmental or industrial hygiene any time during the Term. Landlord covenants and condition or matters as may now or at any time hereafter agrees that no part of the Communication Facility be in effect, that are now or were related to that party's constructed, erected or placed on the Premises by Tenant activity conducted in, or on the Property. will become, or be considered as being affixed to or a (b) Landlord and Tenant agree to hold part of, the Property, it being the specific intention of the harmless and indemnify the other from and to assume all Landlord that all improvements of every kind and nature duties, responsibilities, and liabilities at is sole cost and constructed, erected or placed by Tenant on the Premises expense, for all duties, responsibilities and liability (for will be and remain the property of the Tenant and may be payment of penalties, sanctions, forfeitures, losses, costs, removed by Tenant at any time during the Term. Within or damages) and for responding to any action, notice, one hundred twenty (120) days of the termination of this claim, order, summons, citation, directive, litigation, Agreement, Tenant will remove all such improvements. investigation or proceeding which is related to (i) failure Tenant will, to the extent reasonable, restore the Premises to comply with any environmental or industrial hygiene to its condition at the commencement of the Agreement, law, including without limitation any regulations, reasonable wear and tear and loss by casualty or other guidelines, standards or policies of any governmental causes beyond Tenant's control excepted. Tenant will not authorities regulating or imposing standards of liability or be responsible for the replacement of any trees, shrubs or standards of conduct with regard to any environmental or other vegetation nor will Tenant be required to remove industrial hygiene conditions or matters as may now or from the Premises or the Property any underground hereafter be in effect, or (ii) any environmental or utilities. industrial hygiene conditions that arise out of or are in any way related to the condition of the Property or 13. MAINTENANCE/UTILITIES. activities conducted by the party thereon, unless the (a) Tenant will keep and maintain the environmental conditions are caused by the other party. Premises in good condition, reasonable wear and tear and (c) The indemnifications of this Paragraph damage from the elements excepted. Landlord will 10 specifically include reasonable costs, expenses and maintain and repair the Property and access thereto, in fees incurred in connection with any investigation of good and tenantable condition, subject to reasonable wear Property conditions or any clean-up, remediation, and tear and damage from the elements. removal or restoration work required by any (b) Tenant will be solely responsible for governmental authority. The provisions of this Paragraph and promptly pay all utilities charges for electricity, 10 will survive the expiration or termination of this telephone service or any other utility used or consumed Agreement. by Tenant on the Premises. Landlord will fully cooperate with any utility company requesting an easement over, 11. ACCESS. At all times throughout the Term of under and across the Property in order for the utility this Agreement, and at no additional charge to Tenant, company to provide service to the Tenant. In the event Tenant and its employees, agents, and subcontractors, Tenant cannot secure its own metered electrical supply, will have access to the Premises Monday —Friday (8:00 Tenant will have the right, at its own cost and expense, to am- 5:00 pm) for regular maintenance and repairs and submeter from the Landlord. Tenant will pay on a twenty-four (24) hour, seven (7) day a week access for monthly basis the current local utility company rate for emergencies for the installation, maintenance and submetered electric, after the meter is read by the operation of the Communication Facility and any utilities Landlord and billed to Tenant. Landlord will not be serving the Premises and Landlord hereby grants to responsible for interference with, interruption of or Tenant an easement for such access. Upon Tenant's failure, beyond the reasonable control of Landlord, of request, Landlord will execute a separate recordable - such services to be furnished or supplied by Landlord. easement evidencing this right. In the event any public utility is unable to use the access provided to Tenant the 14. DEFAULT AND RIGHT TO CURE. Landlord hereby agrees to grant an additional access (a) The following will be deemed a default by either to Tenant or to the public utility, for the benefit of Tenant and a breach of this Agreement: (i) non-payment Tenant, at no cost to Tenant. of Rent if such Rent remains unpaid for more than twenty (20) days after receipt of written notice from Landlord of 12. REMOVAL/RESTORATION. All portions of such failure to pay; or(ii) Tenant's failure to perform any the Communication Facility brought onto the Property by other term or condition under this Agreement within 4 rev.9/24/2002 Option Structure Lease forty-five (45) days after receipt of written notice from Attn.: Lease Management Department, Re: Cell Site # Landlord specifying the failure. No such failure, L1047/NYNYNY2036; with a copy to AT&T Wireless, however, will be deemed to exist if Tenant has 15 East Midland Avenue, Paramus, New Jersey 07652, commenced to cure such default within such period and Attn.: Legal Department, Re: Cell Site # provided that such efforts are prosecuted to completion LI047/NYNYNY2036; and as to Landlord, PO Box 425, with reasonable diligence. Delay in curing a default will Fishers Island, NY 06390. Either party hereto may be excused if due to causes beyond the reasonable control change the place for the giving of notice to it by thirty of Tenant. If Tenant remains in default beyond any (30)days written notice to the other as provided herein. applicable cure period, Landlord will have the right to exercise any and all rights and remedies available to it 17. SEVERABILITY. If any term or under law and equity, including the right to cure Tenant's condition of this Agreement is found unenforceable, the default and to deduct the costs of cure from any moneys remaining terms and conditions will remain binding upon owed by Landlor to Tenant. the parties as though said unenforceable provision were (b) The following will be deemed a default not contained herein. However, if the invalid, illegal or by Landlord and a breach of this Agreement. Landlord's unenforceable provision materially affects this Agreement failure to perform any term, condition, or breach of any then the Agreement may be terminated by either party on warranty or covenant under this Agreement within forty- ten (10) days prior written notice to the other party five (45) days after receipt of written notice from Tenant hereto. specifying the failure. No such failure, however, will be deemed to exist if Landlord has commenced to cure the 18. CONDEMNATION. In the event Landlord default within such period and provided such efforts are receives notification of any condemnation proceedings prosecuted to completion with reasonable diligence. affecting the Property, Landlord will provide notice of the Delay in curing a default will be excused if due to causes proceeding to Tenant within forty-eight (48) hours. If a beyond the reasonable control of Landlord. If Landlord condemning authority takes all of the Property, or a remains in default beyond any applicable cure period, portion sufficient, in Tenant's sole determination, to Tenant will have the right to exercise any and all rights render the Premises unsuitable for Tenant, this available to it under law and equity, including the right to Agreement will terminate as of the date the title vests in cure Landlord's default and to deduct the costs of cure the condemning authority. The parties will be entitled to from any monies owed to Landlord by Tenant. share in the condemnation proceeds in proportion to the values of their respective interests in the Property, which 15. ASSIGNMENT. Tenant may assign, sell or for Tenant will include, where applicable, the value of its transfer its interest under this Agreement without the Communication Facility, moving expenses, prepaid Rent, prior approval or consent of Landlord, to the Tenant's and business dislocation expenses. Tenant will be entitled principal, affiliates, subsidiaries, subsidiaries of its to reimbursement for any prepaid Rent on a prorata basis. principal, or to an entity which acquires all or substantially all of the Tenant's assets in the market 19. CASUALTY. Landlord will provide notice to defined by the Federal Communications Commission in Tenant of any casualty affecting the Property within which the Property is located by reason of merger, forty-eight (48) hours of the casualty. If any part of the acquisition, or other business reorganization. Upon Communication Facility or Property is damaged by fire notification to Landlord of such assignment, transfer, or or other casualty so as to render the Premises unsuitable, sale, Tenant will be relieved of all future performance, in Tenant's sole determination, then Tenant may liabilities and obligations under this Agreement. 'Tenant terminate this Agreement by providing written notice to will not otherwise assign this Agreement without the Landlord, which termination will be effective as of Landlord's consent. the date of such damage or destruction. Upon such termination, Tenant will be entitled to collect all 16. NOTICES. All notices, requests, demands insurance proceeds payable to Tenant on account thereof and communications hereunder will be given by first class and to be reimbursed for any prepaid Rent on a prorata certified or registered mail, return receipt requested, or basis. by a nationally recognized overnight courier, postage prepaid, to he effective when properly sent and received, 20. WAIVER ­_OF LANDLORD'S LIENS. refused or returned undelivered. Notice will be addressed Landlord hereby waives any and all lien rights it may have, to the parties as follows. As to Tenant, AT&T Wireless, statutory or otherwise, concerning the Communication 279 Prospect Park Drive, Rancho Cordova, CA 95670, Facility or any portion thereof. The Communication 5 rev.9/24/2002 Option Structure Lease Facility shall be deemed personal property for purposes of rightful set-off against the deposit after a default this Agreement, regardless of whether any portion is (including the expiration of applicable grace periods), will deemed real or personal property under applicable law, and be returned to Tenant along with any interest accrued Landlord hereby consents to Tenant's right to remove all or thereon (less one percent(1%)per annum fee to Landlord any portion of the Communication Facility from time to for management of the account). time in Tenant's sole discretion and without Landlord's consent. 23. REMOVAL BOND. Lessee shall post a Removal Bond upon issuanc ermit in the amount of 21. INSURANCE. (a) Tenant will carry during form and the Term, at its own cost and expense, the following content reasonably acceptable to Landlord. insurance: (i) "All Risk" property insurance for its property's replacement cost; (ii) commercial general 24. MISCELLANEOUS. liability insurance with a commercial general liability (a) Amendment/Waiver. This endorsement having a minimum aggregate amount of Agreement cannot be amended, modified or revised coverage of $5,000,000 in combined general and excess unless done in writing and signed by an authorized agent coverage which policies of insurance shall name the of the Landlord and an authorized agent of the Tenant. Landlord and the Diocese of Norwich as additional No provision may be waived except in a writing signed insured's and (iii) Workers' Compensation Insurance as by both parties. required by law. Tenant shall annually provide Landlord (b) Memorandum of Option to Lease/Short Form satisfactory evidence of such coverage to be maintained Lease. Either party will, at any time upon fifteen (15) during the Lease Term and all policies shall be endorsed days prior written notice from the other, execute, so that Landlord shall be given not less than thirty (30) acknowledge and deliver to the other a recordable days advanced notice of cancellation. The failure of Memorandum of Option to Lease, Memorandum of Lease Tenant to maintain such policies of insurance as herein and/or Short Form of Lease. Either party may record required shall be an express default under the terms of such memoranda and/or Short Form of Lease at any time, this Agreement. in its absolute discretion. (c) Bind and Benefit. The (b) In the event Landlord incurs any increase in its terms and conditions contained in this Agreement will run insurance premiums directly attributable to Tenant's use with the Property and bind and inure to the benefit of the and occupancy of the Premises, Tenant will reimburse parties, their respective heirs, executors, administrators, Landlord in full for any such reasonable cost or expense successors and assigns. upon thirty (30) days written notice from Landlord. Bills, (d) Entire Agreement. This invoices, correspondence and notices from Landlord's Agreement and the exhibits attached hereto, all being a insurer will be prima facie evidence of any sums due part hereof, constitute the entire agreement of the parties pursuant to this Paragraph and admissible as evidence of hereto and will supersede all prior offers, negotiations same in any legal proceeding or action. Landlord warrants and agreements. that is has investigated with its insurance company,and has (e) Governing Law. This been advised that Tenant's use of the Premises as presently Agreement will be governed by the laws of the state in contemplated by this Agreement will not cause Landlord which the Premises are located, without regard to any increase in its insurance premiums. If, in the future, conflicts of law. Landlord's insurance company requires premiums which (f) Interpretation. Unless otherwise Tenant deems excessive,Tenant may elect to terminate this specified, the following rules of construction and Agreement immediately. interpretation apply: (i) captions are for convenience and reference only and in no way define or limit the 22. SECURITY DEPOSIT. At the commencement of construction of the terms and conditions hereof; (ii)use of this Agreement, Tenant will deposit with Landlord the the term "including" will be interpreted to mean sum of 40 "including but not limited to"; (iii) whenever a party's VperfMormance as security for the full and faith consent is required under this Agreement, except as of this Agreement by Tenant. Such sum will otherwise stated in the Agreement or as same may be be segregated by Landlord in an interest bearing trust duplicative, such consent will not be unreasonably account identified for this Agreement. Upon expiration or withheld, conditioned or delayed; (iv) exhibits are an termination of the Agreement as provided herein, said integral part of the Agreement and are incorporated by sum, or any balance thereof remaining after Landlord's reference into this Agreement; (v) use of the terms 6 rev.9/24/2002 Option Structure Lease "termination" or "expiration" are interchangeable; and such a statement within such time will be conclusively (vi) reference to a default will take into consideration any relied upon by the requesting party that(i)this Agreement applicable notice, grace and cure periods. is in full force and effect, without modification except as (g) Estoppel. Provided the may be properly represented by the requesting party, (ii) requesting party is not in default, Either party will, at any there are no uncured defaults in either party's time upon fifteen (15) business days prior written notice performance, and(iii) no more than one month's Rent has from the other, execute, acknowledge and deliver to the been paid in advance. other a statement in writing (i) certifying that this (h) No Electronic Signature/No Option. Agreement is unmodified and in full force and effect (or, The submission of this Agreement to any party for if modified, stating the nature of such modification and examination or consideration does not constitute an offer, certifying this Agreement, as so modified, is in full force reservation of or option for the Premises based on the and effect) and the date to which the Rent and other terms set forth herein. This Agreement will become charges are paid in advance, if any, and (ii) effective as an Agreement only upon the handwritten legal acknowledging that there are not, to such party's execution, acknowledgment and delivery hereof by knowledge, any uncured defaults on the part of the other Landlord and Tenant. party hereunder, or specifying such defaults if any are claimed. Any such statement may be conclusively relied upon by any prospective purchaser or encumbrancer of the Premises. The requested party's failure to deliver [SIGNATURES AND ACKNOWLEDGEMENTS ON NEXT PAGE] 7 rev.9/24/2002 Option Structure Lease IN WITNESS WHEREOF, the undersigned has caused this Agreement to be executed and effective as of the date the last party executed this Agreement below. "LANDLORD" Our Lady of Grace Roman Catholic Church, a New York Religious Corporation Jr ??,, Print Name: AN�� � � �1 —� t r Its: AA nN i Date: q �} (� "TENANT" CELLULAR TELEPHONE COMPANY, a New York General partnership,d/b/a/AT&T WIRELESS By: "'A Print N e�� Joseph Sweet Its: System-Development Manager Date: [ACKNOWLEDGEMENTS ON NEXT PAGE] 1170415.2 rev.9/24/2002 Option Structure Lease STATE OF NEW YORK ) )SS.: COUNTY OF ) On the day of ,200 before me,the undersigned,personally appeared j i �AQZ1-Z--T VCberso ally known to me or proved to me on the basis of satisfactory evidence to be the indival whose name is subscribed to the within instrument and a owledged to me that he/she executed the same in his/her capacity,and that by his/her signature on the instrument,the indi 'd}ial,or the persZupehalf of which the individual acted, executed the instrument. / BUO STATE OF NEW YORK STATE OF NEW YORK ) NO. 01HA6067785 )SS.: QUALIFIED IN SUFFOLK COUNTY COUNTY OF ) TERM EXPIRES... / /-7 (� r 1 On the day of_ 200_before me,the undersigned,personally appeared personally known to me or proved to me on the basis of satisfactory evidence to be the individual whose name is subscribed to the within instrument and acknowledged to me that he/she executed the same in his/her capacity,and that by his/her signature on the instrument,the individual,or the person upon behalf of which the individual acted, executed the instrument. Notary Public USE THE FOLLOWING FORM OF NOTARY ACKNOWLEDGMENT IF DOCUMENT EXECUTED IN A STATE OTHER THAN NEW YORK STATE: STATE OF ) )SS.: COUNTY OF ) On the day of in the year 200_,before me,the undersigned, personally appeared ,personally known to me or proved to me on the basis of satisfactory evidence to be the individual whose name is subscribed to the within instrument and acknowledged to me that he/she executed the same in his/her capacity,and that by his/her signature on the instrument,the individual,or the person upon behalf of which the individual acted,executed the instrument,and that such individual made such appearance before the undersigned in the (insert the city and state where acknowledgment taken). Notary Public STATE OF ) )SS_: COUNTY OF ) On the___day of in the year 200_,before me,the undersigned, personally appeared ,personally known to me or proved to me on the basis of satisfactory evidence to be the individual whose name is subscribed to the within instrument and acknowledged to me that he/she executed the same in his/her capacity,and that by his/her signature on the instrument,the individual,or the person upon behalf of which the individual acted,executed the instrument,and that such individual made such appearance before the undersigned in the (insert the city and state where acknowledgment taken). !^ Notary Public rev.9/24/2002 Option Structure Lease EXHIBIT 1 DESCRIPTION OF PREMISES Page of _ to the Agreement dated _ ,200_,by and between Our Lady of Grace Roman Catholic Church, a New York Religious Corporation as Landlord,and CELLULAR TELEPHONE COMPANY,a New York partnership,d/b/a AT&T WIRELESS,as Tenant. The Premises are described and/or depicted as follows: rev.9/30/2002 Option Structure Lease BATH EXISTING TELCO DEMARC 3 3 ROOM LOCATED IN STORAGE ROOM STORAGE W a FOYER J o 4I (—T � a T PROPOSED TELCO ROUTED ALONG BASEMENT CEILING TO EQUIPMENT ROOM U.Id ON. O O Y r p U b O N O O '--THRIFT T STORE�� Of EXISTING ENTRANCE INTO 4 m o BASEMENT U � 3 � I PROPOSED ANTENNA CABLES - ROUTED UP TO ANTENNAS IN t T>I SECOND FLOOR OF STEEPLE E— 06 ABOVE U j I PROPOSED AT&T j E i EQUIPMENT ROOM 10� L I EXISTING ENTRANCE INTO I BASEMENT a ORIENTAL AVENUE BASEMENT PLAN ISSUED FOR LEASE 1 scx 3/32 -1-o NORTH This drawing and the design It covers are the property of BECHTEL. They are merely loaned and on the borrower's express agreement that they w; t1 not be reproduced, coped, loaned, exhibited, or used except in the limited way and private use permuted by any written consent given by the lender to the borroorer S 7 Y N &` W 0 7 4 b PROPOSED SECTOR "B" E— t ANTENNAS MOUNTED BEHIND ° PROPOSED STEALTH LOUVER ° PANELS, TYP. OF ALL SECTORS 4 u V O 38'—E RAD. _ OF ANTENNA Z I EXIS'"ING LOUVERS TO j BE REPLACED WITH STEALTH ` Yo LOUVER PANELS, ?YP. OF (3)-- N�� ! GRADE e PROPOSED AT&T EQUIPMENT ' ROOM LOCATED IN BASEMENT NORTHEAST ELEVATION ISSUED FOR LEASE This drawing and the design it covers ore the property of BECHTEL, They are merety loaned and on the borrower's express agreement that they wilt not be _ reproduced, copied, toaned, exhibited, or ,sed Pxcept '.n the limited way and private use permitted by any written consent given by the lender to thN borrower EXISTING ELECTRICAL . METER MOUNTED TO EXTERIOR BUILDING FACDE Y j PROPOSED SUB-METER PROPOSED 200 AMP 8 -9 t/4 POWER PANEL e g PROPOSED ANTENNA CABLES a ROUTED ALONG INTERIOR EXISTING ELECTRICAL Lu s PANEL AND BACKBOARD £ W FACE OF STEEPLE ABOVE TO PROPOSED ANTENNAS -EXISTING SMOKE DETECTOR al 1 X, - EXISTING DOOR TO BE �� REMOVED AND REPLACED r E WITH PROPOSED 3'-0' a I. PROPOSED GROUND CONDUIT , W FIRE-RATED DOOR, TRENCHED TO EQUIPMENT ? —TYP. OF {2) ROOM FROM PROPOSED �, � PROPOSED 3'-0' EXTERIOR GROUND HALO� -�� N FIRE-RATED DOOR, TYP z - PROPOSED 48"x48" I EXISTING CHURCH ORGAN o of T '� /—PUMP TO BE RELOCATED ELCO BACKBOARD E r- — WITHIN ROOM IF NECESSARY jg4 oZ ' PROPOSED THROUGH WALL I PROPOSED 2 HR. EXHAUST FAN TO REPLACE _-- � � FIRE-RATED WALL, TYP. EXISTING WINDOW 2 J N o NI THRIFT i 3 4� i /—THRIFT o s /V V Ye EXISTING SCREEN DOOR N o0 EXISTING STORM DRAIN TO BE W CLEARED OF DEBRI 0 46 EXISTING STAIRS FROM EXISTING HAND RAILING EXTERIOR GRADE TO �� ? PROPOSED EQUIPMENT, ROOM AT BASEMENT <f< zi S { 7: ENLARGED EQUIPMENT PLAN ISSUED FOR LEASE 1 NORTH This drawing and the design It covers are the property of BECHTEL, They are merety toaned and on the borrower's express agreement that they watt not be reproduced, coped, Waned, exhibited, cr used except n the t n ted way and private use permitted by any written consent given by the tender to the borrow- I I l ' I PROPOSED COAXIAL ANTENNA g CABLES ROUTED FROM BASEMENT EQUIPMENT ROOM BELOW THROUGH g W $ EXISTING FIRST FLOOR STORAGE J CLOSET TO ANTENNAS IN UPPER k STEEPLE ABOVE n � G STORAGE CLOSET ItIA I CONGREGATION EXISTING STATUE � ;� AREA O V O EXISTING BAPTISMAL POOL — �8a= EXISTING ACCESS HATCH - N TO SECOND FLOOR STEEPLE = o ° I ABOVE EXISTING STATUE ` a r.— _ _ EXISTING CONFESSIONAL co BOOTHS }" 'EN U Vl w 46 a PROPOSED ENTRANCE TO PROPOSED AT&T EQUIPMENT a \ 3 ROOM IN BASEMENT BELOW •^ y v t t <= Si FIRST FLOOR STEEPLE PLAN ISSUED FOR LEASE 1 NORTH I This drawing and the design ;t covers are the property of BECHTEL. They are merely loaned and on the borrower's express agreement that they w 11 not be reproduced, Coped, loaned; exh b ted, or used except in the limited way and private use pern;tted by any wr tten consent g-ven by the lender to ice gnrrCWl?r PROPOSED SECTOR LINE OF EXISTING ANTENNA MOUNTED BEHIND a PROPOSED STEALTH OUVER ROOF BELOW PANEL e g U.) a f —+ EXISTING LOUVERS TO BE V W c n ' REPLACED WITH STEALTH —� `'' p LOUVER PANELS, TYP. PROPOSED COAXIAL ANTENNA zo X OF (3) 4 CABLES ROUTED FROM BASEMENT 0 D a c EQUIPMENT ROOM BELOW = EXISTING HORN, 6 . TYP, OF (4) a PROPOSED SECTOR "C" ; ANTENNAS MOUNTED BEHIND EXISTING ACCESS 'HATCH PROPOSED STEALTH LOUVER TO FIRST FLOOR BELOW PANEL I � M 0 0 EXISTING WOOD SUPPORT �gN FRAME SUSPENDED FROM � N� �o�l STRUCTURE ABOVE A W ° W SECTOR "C" 310' EAST OF ,! 3 TRUE NORTH o a Z EXISTING STEEPLE N w LINE OF EXISTING � PROPOSED SECTOR "B" ROOF BELOW ANTENNAS MOUNTED BEHIND m p ��N PROPOSED STEALTH LOUVER w z PANEL bi v o � w v o' _ Ln N ORIENTAL AVENUE I I I ISSUED FOR LEASE SECOND FLOOR STEEPLE PLAN NORTH II 1 I This drawing and the de5lgn .t cever5 ore the property of BECHTEL. They are Merely loaned and on the borrower's express agreement tact they wilt not be reproduced, coped, leaned, exn,b:ted, or used except in the l m;ted way and pr vote use permitted by any written consent given by the tender to the borrcwf,r Sa Jud N.Y.B.T.U.Form 9007 s 10.53.2514—Bargain and Sale Deed.with Covenant gains Grantor'&Aar—ladividual or Corporation �.S.I.R.s.—== :.:._.. «ER4242 PA6119 THIS INDENTURE, made the 27th day of Docewber nineteen hundred and f i ft,-sip: me BETWEEN 'J iA") .' ..rti^" , TrC., a domestic corporati:)n, orpanlzed and nd e xi 1n i uncle canes u virtue of the law;; of tiro State of New York, rs principal offices located at Fishers Islam, Town of ;i:'ZOld, Count7T of Suffolk and State of New vorLc, 5 party of the first part,and 0 !AP" 07 G°,ACE C,-!MC1:, a reil7ious organization, orr,,anized and t lai;in; unaer and b­ virtue of th.e laws ,Y_ the otate of New York, vi ,rt its principal offices located at Fishers Island, Town of S01i:1:01 r, Court,,* of S1zfVolk and Stare of ?,Tew York s.e Se party of the second part, 't WM SSETH,that the party of the first part,in consideration of— — — — — — — — — — — — — ly js - - - - - - TEN A;'JD NTO/luo ($IO.OU)- - - - - - - - - - - - - dollars, f lawful money of the United States, and other good and valuable consideration paid by the party of the second part,does hereby grant and release unto the party of the second part, the heirs or it ' successors and assigns of the party of the second part forever, e !, ALL that certain plot,piece or parcel of land, with the buildings and improvements thereon erected, situate, lying and being tLIkK at Fishers Island, Town of Southold, County of Suffolk, and State of New York, being bounded and described as follows: BE',T1,TLI1G at a stone monument on the easterly line of Oriental Avenue at the dividing line between the herein p conveyed tract and otner land of this Grantee, ss.id monument being 1 976.20 feet North of a point w il.ch is 1534.12 feet West of another monument marking; tip, United States Coast and Geodetic Survey Triangulation i- Station "PROS", and, running thence North 43 decrees 49 minutes 15 seconds East, 4U0.05 feet to a monument on the southwesterly line of a Alpine Avenue; running thence along the southwesterly line of A1pin6 Ave- n1e, North 36 de„Tees Ul minute 00 seconds West, 117.� f; feet to a drill nole in a boulder; running thence South 71 degrees 22 m9.nutes 30 seconds West, 1172.88 feet along the southeasterly l .ne of Alpine Avenue and an extension of this line; r.)nntnr thence South %x. degrees 37 minutes 30 seconds East 25.00 feet; ' j r,1nn'n thence South 56 degrees 53 minutes 00 seconds West, 1;` .29 feet to tfte said easterly line of'Oriental Avenue, runnin,- t1 ende along the easterly -line of Oriental Avenue i South 1L. degrees 11 minutes 10 seconds, `ra'st, 12�>.J.': feet to a monument; ' r,-nvnin- thence, alon^; the easterly line of Oriental Avenue n degrees 56 m-.nutes to sec.-)nds Sp st, 100.3' feet to a monu- me;t; if i USER4242 !PAGE 120 I� II running thence, along the easterly side of Oriental Avenue, South 29 degrees 19 minutes 15 seconds Eabt, 13.54 feet to the point of beginning and containing an area of 1.30 i acre, more or less. The herein conveyed premises a-e sub,jedt to An existing right of way, 10 feet in width, reserved to the Fishers Island Electric Corporation, The Fishers Island Telephone Company and to Fishers Island Farms, Inc., for the purpose of installing, maintaining or servicing electric and telephone utilities, the center line being hounded and described as follows: BE6iffNINh' at a point on the easterly line of Oriental Avenue said point being 1744.13 feet North of a point which is 1556.48 feet West of said "THOS" monument and, running thence gouth U degrees 11 minutes 20 seconds East, �445a1E��. 1e running thence North 50 degrees 02 minutes East, 201.36 feet to g point on the Southwesterly line of Get Avenue, 5.0 feet Northwesterly from a monument. ftfjof. 3 i y I I t,a • r n a 0 1 z� i o� ovit <.a o y of v2-ecc-- cwuitc�-/ � �i i /OO Spa Fi: I olu SL a �4�vE �;pj.f3Zo C' IV s oa C.y sF2 1- —" ,vzozz.s 7/.2 G u .o X29 1 P P4 4 AJ Nl q 0 Z Fog c✓'Es T ZAID ZAAl0 CO., 1A.1 C. Ji/oc�/nvG L�l ao To t3E Co1v6 YE'O To 002 LADY of 6/I,4CE CNU&C14 F/SNE/IS /SLA!/O L/O/ZA2Y -q UOC/AT/OAI �� �i � /�i3NE/ZS ✓S L�sN/J �t/.�/. a � CE/LT/<Y TNAT T�71,j ,�,. �GRt�•.' /�_ 4o FT• CNAN4 cE/!(,/S�G/`fE2 Ptga/ /3 a 2/16c T. h� y< haw. od jC.-o/ 00 l 0 I n ° ti oa a� °53�y 1..?� I I i � .«ah • � o N,q3��,d IV 6A U, 1v 6 A 30 0 4 A ��_ ,��'• L- r'�c�f[r Y /fix � w ti� i C/ ,, /�, ��S B8•, i�2o E « e 'r `s Gv/J3 G-fe x� Q n � Y VN a N /876.7_0 w/534./2, x �+ 0,(/ ! Co _ F/JO.�> (/,f COAST q.v0 GEOOE'TiG `SUQVEY J 2/'C' 7WIA N6 V. 4,rio-V JT.4T/OA/ O �Cic u1o77� Stu, ■ �f WER4242 PA9123 TOGETHER with all right, title and interest, if any,of the party of the first part in and to any streets and hutting the above described premises to the center lines thereof, TOGETHER with the appurtenances and all the estate and rights of the party of the first part in and to �rPnlltfs, TO HAVE AND TO HOLD the premises herein granted unto the party of the second part, the heirs or +' 1,:k><Ors and assigns of the party of the second part forever. J � ' 1; I v t' t � yY .fit t I k, s�y'x 1 Pq, g AND the party of the first part covenants that the party of the first part has not done or suffered anything whereby the said premises have been incumbered in any way whatever,except as aforesaid. A n AND the party of the first part, in compliance with Section 13 of the Lien Law,covenants that the party of 1 the first part will receive the consideration for this conveyance and will hold the right to receive such consid- io' ' oration as a trust fund to be applied first for the purpose of paying the cost of the improvement and will apply the same first to the payment of the cost of the improvement before using any part of the total of the same for any other purpose. 1 The word"party"shall be construed as if it read"parties"whenever the sense of this indenture so requires. IN WITNESS WHEREOF,the party of the first part has drily executed this deed the day and ear first above :..ritten• ffr1,;Q�t4"! rNE5ENl'E OF: WEb T END t�A_ND CUMtANYy 4 V c, `r by. Pros n � � ;,u.. A$n.M ili.mm'.w.•x uwh W.N.,'n"""Y,., COUNTY OF sw STATE OF NEW YORK,COUNTY OF all On the day of 19 before me On the day of 19 before me personally came personally came to me known to be the individual described in and who to me known to be the individual described in and who executed the foregoing instrument, and acknowledged that executed the foregoing instrument, and acknowledged that executed the same. executed the same. I w 5:. STAIR Of NEW YORK,COUNTY OF SUFFOLK ss: STATE OF NEW YORK,COUNTY OF a: day of0embers 1956 , before me On the day of 19 , before me On the 7 personally came A P L. FEI�GUSQ�1 personally came to me known,who, ng y me duly sworn, d depose and the subscribing witness to the foregoing instrument, with say that he resides at No. whom I am personally acquainted, who, being by me duly 417 Park Avenue, New York, N.Y. sworn,did depose and say that he resides at No. that he is the President Of WEST END LAND COMIA��yy INC that he knows ,"t5e'oorpora that described in and which executed the foregoing instrument;that he to be the individual knows the seal of said,corporation; that the seal affixed described in and who executed the foregoing instrument; to said instrument is such corporate seal; that it was so that he, said subscribing witness, was present and saw affixed by order of the board of directors of said corpora- execute the same;and that he,said witness, a . tion, and that he signed h i gtame thereto by like order. at the same time subscribed h name as witness thereto. otary Publiff JAMES H..WyM11S NOTARY PUBLIC,State of New York !r' No. 31-9758500 ih QwIlfied in Ni- York County Gmmlimion Exp—Mot&30, 1958 f„ x V ° w iSC' g ; 3 I•y z S Ef O { U , z O aq 2S `Nl a � z ;A R �' � � o r^] z Tq7 a �j( i "Sol. a E C" i.► U° � 1 It Ir RECORDED Lj oo L; } V JHIv n] N ,Q ac a >e 5 a a RE, NIELSEN, HUBER & COUGHLIN, LLP ATTORNEYS AT LAW 36 NORTH NEW YORK AVENUE HUNTINGTON, NEW YORK 11743 TELEPHONE: (631) 425-4100 FACSIMILE: (631) 425-4104 OF COUNSEL WILLIAM J. NIELSEN May 21,2013 By Hand Mr.Michael Verity Building Department Town of Southold Annex Building 54375 Route 25 Southold,NY 11971 RE: New Cingular Wireless PCS,LLC("AT&T") Proposal to modify existing telecommunications facility at Premises: Our Lady of Grace Church Oriental Avenue, Fishers Island,NY SCTM#: 1000—9—7— 11.1 Dear Mr. Verity: We are the attorneys for AT&T in connection with its proposal to upgrade its existing facility at the subject premises. The modification proposed is part of AT&T's "LTE" (Long Term Evolution) project which will allow AT&T to provide better,faster and more reliable service in the Town. The Middle Class Tax Relief and Job Creation Act of 2012, codified at 47 United States Code §1455 (a copy of which is enclosed) provides that "a State or local government may not deny, and shall approve,any eligible facilities request for a modification of an existing wireless tower or base station that does not substantially change the physical dimensions of such tower or base station." We respectfully submit that this proposal is an "eligible facilities request" pursuant to 47 U.S.C. §1455(a)(2) as it proposes only to replace and collocate certain transmission equipment on the existing tower and modify equipment inside its existing equipment shelter. As such, the proposed modification will not "substantially change the physical dimensions"of the existing tower or base station. Moreover, the Telecommunications Act of 1996, codified at 47 United States Code § 332, as interpreted by the Federal Communications Commission ("FCC") in its Declaratory Ruling 09-99 and Order On Reconsideration 10-144, requires that applications such as AT&T's be processed within 90 days. We enclose the following in support of the proposed eligible facilities request: 1. Town of Southold Building Permit Application form detailing the eligible facilities request; 2. Owner's Authorization Affidavit; 3. Building Permit Application fee: Check of Bechtel Corporation (Check No. 1170) in the amount of$500.00; 4. Two (2) counterparts of RF Exposure Analysis prepared by Bernard Morgan of Bechtel Communications, Inc., and dated November 27, 2012, demonstrating the project's compliance New Cingular Wireless PCS, LLC(AT&T) Proposal to modify existing facility at Our Lady of Grace Church May 21,2013 Page 2 of 2 with the FCC's Maximum Permissible Exposure regulations; 5. Two (2) counterparts of Structural Analysis Report, prepared by Bechtel Associates Professional Corporation,dated May 2,2013, documenting the facility's structural compliance with local, state and federal codes; 6. Copies of AT&T's FCC Licenses; 7. Copy of Deed; 8. Copy of Lease Agreement between Our Lady of Grace Roman Catholic Church and AT&T, then doing business as Cellular Telephone Company,dated October 1, 2002: 9. Application for Certificate of Occupancy; and 10. Bechtel Corporation Check number 1399 in the amount of $50.00, which amount represents the required Certificate of Occupancy fee. 11. Copy of property survey prepared by Barrett Bonacci & Van Weele, PC, dated December 22, 2008; 12. Four (4) sets of Construction Drawings with Site Plans and Elevations, prepared by Bechtel Associates Professional Corporation,revision 0,dated April 23,2013; and 13. Our firm's check number 1541, payable to the Town of Southold, in the sum of $8,500.00, to be held in escrow for the technical consultant review fee. We request that our office be provided with detailed invoices for all expenses billed against this escrow amount. We respectfully request that the instant proposal be processed in accordance with the above and that the appropriate Permit be issued at this time. We respectfully request that our office be contacted when the Permit is ready to be picked up. We can be reached at(631)425-4100. Very truly yours, RE,NIELSEN,HUBER&COUGHLIN,LLP By: hn ou JC:cb Enclosures cc by email w/o encls.: Ms. Heather Lanza,Planning Director . �s5 I V� RE, NIELSEN, HUBER & COUGHLIN, LLP ATTORNEYS AT LAW 36 NORTH NEW YORK AVENUE HUNTINGTON, NEW YORK 11743 TELEPHONE: (631) 425-4100 FACSIMILE: (631) 425-4104 Ez his N July 2, 2013 �,By Hand j i Mr. Michael Verity Building Department Town of Southold Annex Building 54375 Route 25 Southold,NY 11971 RE: New Cingular Wireless PCS, LLC ("AT&T") Building Permit - Proposal to modify existing telecommunications facility at Premises: Our Lady of Grace Church Oriental Avenue, Fishers Island, New York SCTM#: 1000—9—7— 11.1 Dear Mr. Verity: On behalf of AT&T, and pursuant to your office's request, we enclose, herewith, our firm's check number 1582 in the amount of$50.00, which amount represents the required Certificate of Occupancy fee. This check should replace Bechtel Check No. 1399, which was dated May 8, 2012. We ask that said outdated check be returned to our office. We respectfully request that the Building Permit be released to our office at this time. Thanking you for your courtesies, we remain Very truly yours, RE,NIELSEN, HUBER& COUGHLIN, LLP By: c-A Cou JJC:mk Enclosures _N . PROJECT DESCRIPTION 02 o MODIFICATION TO EXISTING TELECOM FACILITY COMPRISING OF EQUIPMENT, ANTENNAS AND ASSOCIATED m = CABLES. o 43 Q at &t PROJECT INFORMATION 3 " v SITE ADDRESS: ORIENTAL AVENUE AND ETTRICK AVENUE o- c FISHERS ISLAND, NY 06390 0 o PROPERTY OWNER: OUR LADY OF GRACE CHURCH 0 o ORIENTAL AVENUE, FISHERS ISLAND M °- NY 06390 NUMBER :U■ c 0 APPLICANT ADDRESS: NEW CINGULAR WIRELESS PCS, LLC ("AT&T") 340 MT. KEMBLE AVENUE NAMEm v m MORRISTOWN, NJ 07960 ■ FISHERS ISLAND a� JURISDICTION: TOWN OF SOUTHOLD PROPERTY TAX ID: SECTION 9, BLOCK 7, LOT 11 .1 VICINITY MAP APPLICABLE BUILDING CODES AND STANDARDS L_ ZONING DISTRICT: R-80 co > LATITUDE: N 41' 15' 38.7" (NAD 83) FROM MORRISTOWN,NJ: N LONGITUDE: W 72' 0' 51 .99" (NAD 83) HEAD NORTH—EAST ON US-202 N/MT KEMBLE AVE TOWARDS ZAMROK WAY, SLIGHT RIGHT ONTO MARKET SUBCONTRACTOR'S WORK SHALL COMPLY WITH ALL APPLICABLE NATIONAL, STATE, AND LOCAL 0 ELEVATION: 75.7'± A.G.L. (NAVD 83) ST, TURN RIGHT ONTO W PARK PL, TAKE THE 1ST LEFT ON TO US-202 N, CONTINUE ONTO MORRIS ST, CODES AS ADOPTED BY THE LOCAL AUTHORITY HAVING JURISDICTION (AHJ) FOR THE LOCATION. v SLIGHT LEFT TO MERGE ONTO 1-287 N TOWARDS 1-80, ENTERING NEW YORK, KEEP RIGHT AT THE FORK, THE EDITION OF THE AHJ ADOPTED CODES AND STANDARDS IN EFFECT ON THE DATE OF o CURRENT USE: TELECOMMUNICATIONS FACILITY FOLLOW SIGNS FOR 1-87 S/1-287/TAPPAN ZEE BR/NEW YORK CITY/NEW YORK THRUWAY AND MERGE CONTRACT AWARD SHALL GOVERN THE DESIGN. o 0 PROPOSED USE. TELECOMMUNICATIONS FACILITY ONTO 1-287 E/1-87 S, CONTINUE TO FOLLOW 1-287 E, PARTIAL TOLL ROAD, TAKE THE EXIT ONTO 1-95 0- 0 N, ENTERING CONNECTICUT, SLIGHT RIGHT TO STAY ON 1-95 N (SIGNS FOR NEW LONDON/PROVIDENCE), RF DATA SHEET TAKE EXIT 83 TOWARDS CT-32 N/NORWICH/DOWNTOWN/NEW LONDON, MERGE ONTO 1-95 FRONTAGE RD, BUILDING CODE: BUILDING CODE OF NEW YORK STATE — 2010 CONTINUE ONTO HUNTINGTON ST, TURN LEFT ONTO GOVERNOR WINTHROP BLVD, TURN LEFT ONTO WATER TAKE THE NEW LONDON — FISHERS ISLAND FERRY TO FISHERS ISLAND DATE ISSUED: 01/31/2013 REVISION: V03 ST, TURN RIGHT ONTO FERRY ST, , ELECTRICAL CODE: NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) 70—NATIONAL ELECTRICAL CODE CL ENTERING NEW YORK, CONTINUE STRAIGHT, TURN LEFT TOWARDS EQUESTRIAN AVE, TURN LEFT ONTO co o EQUESTRIAN AVE, KEEP RIGHT AT THE FORK, TURN RIGHT ONTO ORIENTAL AVE, SLIGHT LEFT ONTO ALPINE (NEC) — 2008 N AVE, SLIGHT RIGHT, DESTINATION WILL BE ON THE RIGHT FIRE/LIFE SAFETY CODE: FIRE CODE OF NEW YORK STATE — 2010 v E u DRAWING INDEX REV LIGHTNING PROTECTION CODE: NFPA 780-2008 LIGHTNING PROTECTION CODE co v SUBCONTRACTOR'S WORK SHALL COMPLY WITH THE LATEST EDITION OF THE FOLLOWING D STANDARDS. NYNYNY0801 -T01 TITLE SHEET o NYNYNY0801 -SP1 SITE PLAN 0 F AMERICAN CONCRETE INSTITUTE (ACI) 318, BUILDING CODE REQUIREMENTS FOR STRUCTURAL NYNYNY0801 -A01 ROOF PLAN, ANTENNA PLAN & GENERAL NOTES 0 q�F CONCRETE. N ° NYNYNY0801 -A02 EQUIPMENT PLAN &. NOTES 0 AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC), MANUAL OF STEEL CONSTRUCTION, . o NYNYNY0801 -A03 BUILDING ELEVATION & DETAILS 0 THIRTEENTH EDITION. U NYNYNY0801 -A04 RRH MOUNTING DETAILS 0 N o • _ ANSI/TIA.=,(IELEC MMUNICATIONS INDUSTRY ASSOCIATION) 222—F (1996), STRUCTURAL STANDARDS -�' NYNYNY0801 -A05 REMOTE RADIO HEAD RRH MOUNTING, LTE 0 FOR STEEL ANT NNA TOWER AND ANTENNA SUPPORTING STRUCTURES. m o CONDUCTOR SIZES & GPS UNIT MOUNTING DETAIILS TIA 607, COMMERCIAL BUILDING GROUNDING AND BONDING REQUIREMENTS FOR 0 .- NYNYNY0801 -A06 DC POWER SURGE PROTECTION 0 SITE TELECOMMUNICATIONS. & DC POWER (OVP) POLE MOUNTING DETAILS Q > INSTITUTE FOR ELECTRICAL AND ELECTRONICS ENGINEERS (IEEE) 81 , GUIDE FOR MEASURING a� NYNYNY0801 -E01 SYSTEM DIAGRAM 0 = Q SYSTEMRESISTIVITY, GROUND IMPEDANCE, AND EARTH SURFACE POTENTIALS OF A GROUND NYNYNY0801 -E02 RRH WIRING DIAGRAM 0 0 0 w 9�,0� IEEE 1100 (1999) RECOMMENDED PRACTICE FOR POWERING AND GROUNDING OF ELECTRONIC NYNYNY0801 -E03 ELECTRICAL, TVSS NOTES, ABBREV. & SYMBOLS 0 0 cy-, tiF EQUIPMENT ip .0' NYNYNY0801 -E04 GROUNDING NOTES & DETAILS 0 ��F IEEE C2, NATIONAL ELECTRIC SAFETY CODE — LATEST VERSION 0 E � o TELCORDIA GR-1275, GENERAL INSTALLATION REQUIREMENTS 4- •� p,�� ANSI T1 .31 1 , FOR TELECOM — DC POWER SYSTEMS — TELECOM, ENVIRONMENTAL PROTECTION a� DOCUMENT REVIEW STATUS FOR ANY CONFLICTS BETWEEN SECTIONS OF LISTED CODES AND STANDARDS REGARDING ° MATERIAL, METHODS OF CONSTRUCTION, OR OTHER REQUIREMENTS, THE MOST RESTRICTIVE c: 0 STATUS NO. REQUI REM ENT`'SHALL GOVERN. WHERE THERE IS CONFLICT BETWEEN A GENERAL REQUIREMENT c 1. ❑ ACCEPTED — WITH MINOR OR NO COMMENTS, CONSTRUCTION MAY PROCEED AND A SPECIFIC REQUIREMENT, THE SPE IFIC REQUIREMENT SHALL GOVERN. 2. F-1 NOT ACCEPTED — PLEASE RESOLVE COMMENTS AND RESUBMIT •o Q . : APPROVED AS NOTED Reviewed by: (ENG'G) Date: 0 k , DATE: — B:P: 8/ > PROJECT CONTACTS -0 E - O R ®BY DETAIL ETA(L 1 00 NOTIFY BUILDING DEPARTMENT AT t RF ENGINEER CONSTRUCTION SA COMPLIANCE FOLLOWING®� S IN E IPM FOR THE _c W NAME COMPANY CONTACT NUMBER SCALE: `N.T.S. T01 E®LL®WIN® ION =TWI®NS 1: FOUNDATION =fiW0 REQUIRED I— cn FOR POURED CONCRETE CONSTRUCTION JAYSON GONZALEZ BECHTEL (201 ) 571 -0705 ° ENGINEER RICHARD COAD BECHTEL (201 ) 571 -0730 STRUCTURAL STATEM EN Nsu�fiI'N � �fi�l����`���� Ny N � 0 3 RF ENGINEER AZAD KARIM BECHTEL (201 ) 571 -0651 MUST BE COMPLETE FOR C:O, ALL CONSTRUCTION SHALL MEET THE EXISTING EQUIPMENT ROOM HAS BEEN EVALUATED FOR THE ADD ITIOREWREMEW OEQ0 RMIOTNAi ND NO o Z MODIFICATIONS TO THE EXISTING BUILDING AND FOUNDATION ARE RE � I�� : NOT RESPONSIBLE FOR 0 �19N CONSTRUCTION 9RR®RS: t- c o 0 'c ELECTRICAL {; ,r�k.QFo Ns- M. L., IN P CTION REQU at8ct Q BECHTEL ASSOCIATES SITE NAME;: FISHERS ISLAND m � CORPORATION �Q~G 09 p M c �, PROFESSIONAL CO SITE NUMBER: NYNYNY0801 at&t 4 TT LE SHEET aD * 9 � CERTIFICATION O� A UNIT OF BECHTEL CORPORATION 0 04/23/13 LTE—ISSUED FOR CONSTRUCTION ANA SB RC �, NAILING & CONNECTIOIvti. i 5275 WESTVIEW DRIVE ORIENTAL AVENUE AND ETTRICK AVENUE — FISHERS ISLAND, NY 06390 N0. DATE (REVISIONS BY CHK PP' s�Op0 4g91 JOB NUM DRAWING NUMBER tREV a o FREDERICK, MD 21703 8386 USA FESS,�N0 scALE: As NOTED DESIGNED BY: MG DRAWN BY: MG 25736-415 T3—NYNYNY0801 —T01 U aQ SIZE ?2 i4 Af ��11 C) N+j " 4-j /�\ o o 3 a �° ' 6=00„ E °� //iv�/ J<v 3� 3 � 17.86p a 125'f CL c o/ 40 (SEE NOTE #2) EXISTING (1 ) STORY -c / 4 ° U o o m NOTE: _ /� ��N 3\ 46 - - ° >> 48 K U °c a� 1 . ELEVATIONS SHOWN HEREIN ARE IN AN ASSUMED DATUM. �// 50 O EXISTING (2) STORY MASONRY o m 2. PROPERTY LINES SHOWN FOR FORMER TAX LOT 16 ARE N O BUILDING (RESIDENCE) BASED UPON TAX MAP, DIMENSIONS ARE THEREFORE ;h ( E) a APPROXIMATE. THE EASTERLY LINE OF FORMER TAX LOT N� 22't 35'-1 "t v 3 16, AS SHOWN WAS HELD PARALLEL WITH THE EASTERLY E i LINE FORMER TAX LOT 11 , AS PER L.8499, P. 467. 0 S� P CO 3. THIS SURVEY WAS PREPARED FOR A SPECIFIC PURPOSE >, 56 v Lo AND IS NOT INTENDED TO BE USED FOR A TRANSFER 04 OF TILE OR ANY OTHER FINANCIAL PURPOSE. 54!37'30" 46 30 f TAX LOT 1000-10-8-11 0' ° 44 \ -0 ° NOTE: 25'0 cV' 50 \� a o INFORMATION SHOWN HEREIN IS BASED UPON A SURVEY TAX LOT 100 -9-7-10 ,to 1 �' -� PREPARED BY: BARRETT, BONACCI & VAN WEELE, P.C. 42 L c CIVIL/ENGINEERS/SURVEYORS/PLANNERS, 175A COMMERCE W I 54 ° ° DRIVE HAUPPAUGE, N.Y. 11788 (631 ) 435-1022 (ON o 40 (CURRENT TAX LOT 52 -6 a DECEMBER 27,2002 PROJECT NO: A021059) AND BECHTE ..� 38 1000-9-7-11 .1 O SITE VISIT 12/06/12 ,� DIRT & EXISTING CHURCH BUILDING co GRAVEL � U 2/ /� � z� PARKING ARE NOTE: (FORMERLY TAX LOT z cn �p FOR KEY PLAN SHOWING ADJOINING LAND USES, ROOF OVER N STRUCTURES, ZONING LANDMARK AND OWNERSHIP ALPINE 1000-9-7-11 ) °H °H H 2.5' D PORC 12.5 WITHIN 300' SEE DETAIL 1 SHEET SP-1 AVENUE 0 195 O .� _ °y N w 46 44 N *�. ~o .c: NOTE: 1 42 \G I °y 8. k' z cn v 36 3.s EXISTING .9. c� w •- LOT COVERAGE = 10% �.°� \° (1 ) STORY * I C/) EXISTING AREA INDICATES EXISTING AT&T o 0 (NO CHANGE) FRAME �� ' �? t I EQUIPMENT ROOM LOCATED IN CHURCH LANDSCAPE COVERAGE = 88% oQ ° t 11.s' BUILDING +I +' v BASEMENT AND STEEPLE CONTAINING +, a (NO CHANGE) 20 40 8'� NOR y (CHURCH) T- ANTENNAS ABOVE W E 34 38 ES 12.0. N 36 o d 3 36 44 24. � v 34 40 46 48.1 45.13 °: u 32 38 48 99't (EAST TAX LOT 1000-10-8-12 .a D X29 ° 4 o I CL° 18 30 c -c _ O 0 v E o �i o •� � �pS 34 (FORMERLY TAX L` 1000_10-8-16) EXISTING CHURCH SIGN o d ° 32 a 'v Q 32 34 c ti " o N 2919'15" °\ I NOTE: TO THE BEST OF OUR 0 13.54' W "' )2g� 30 I KNOWLEDGE, THE PROPOSED (sF� EQUIPMENT MODIFICATIONS BY AT&T ,cn ON aNNOTE WILL HAVE LITTLE IMPACT ON THE aH EXISTING NOISE LEVELS AT THE ~ rn EXISTING FACILITY. c °H \ M 0 04 aN =FULL SCALE 1 "-30'-0" O 3 -w SITE PLAN 1 30 15 0 30 60 FT v o 0 SCALE: 1 "-30'= 1 "-0" SP1 HALF SCALE 1 "=60'-0" o O U •u) U) 6 of Nt at&t z BECHTEL ASSOCIATES � p y , m °� N PROFESSIONAL CORPORATION SITE NAME. FISHERS ISLAND �4� °.��� o 0) 5275 OF BECHTEL CORPORATION SITE NUMBER: NYNYNY0801 * s a SITE PLAN .� A T 3 5275 WESTVIEW DRIVE ORIENTAL AVENUE AND ETTRICK AVENUE 0 04/23/13 LTE—ISSUED FOR CONSTRUCTION ANA SB RC •� FISHERS ISLAND, NY 06390 N0. DATE REVISIONS BY CHK PP' �4`Q q3g-� ��'�_ JOB NUMBER DRAWING NUMBER REV FREDERICK, MD 21703-8386 USA 'DRo Pv�' U'L— SCALE: AS NOTED TESIONED BY. Mc DRAWN BY: Mc FE�S1ON " 25736-415 T3-NYNYNY0801 - SP 1 jo SIZE 22 x 34' ANSI 'b N ------ GENERAL NOTES m o I 1 . FOR THE PURPOSE OF CONSTRUCTION DRAWING, THE FOLLOWING DEFINITIONS SHALL EXISTING GPS UNIT I APPLY: o TO REMAIN CONTRACTOR - BECHTEL 3 ~a SUBCONTRACTOR - GENERAL CONTRACTOR (CONSTRUCTION) � � I OWNER - NEW ORIGINAL GLA WIRELESS LLC ("AT&T") OEM - E Q PMENT MANUFACT URER v ° I PROPOSED GPS UNIT & NEW 1/2- COAX CL o j CABLE ROUTED TO BBU (PROVIDE 10' 2. PRIOR TO THE SUBMISSION OF BIDS, THE BIDDING SUBCONTRACTOR SHALL VISIT THE CELL MINIMUM SEPARATION FROM ANTENNAS) SITE TO FAMILIARIZE WITH THE EXISTING CONDITIONS AND TO CONFIRM THAT THE WORK CAN Q j (SEE DETAIL 1/A05) BE ACCOMPLISHED AS SHOWN ON THE CONSTRUCTION DRAWINGS. ANY DISCREPANCY M I FOUND SHALL BE BROUGHT TO THE ATTENTION OF CONTRACTOR. c cv I 0 3. ALL MATERIALS FURNISHED AND INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS, AND ORDINANCES. SUBCONTRACTOR SHALL ISSUE ALL APPROPRIATE NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS, AND ° m I LAWFUL ORDERS OF ANY PUBLIC AUTHORITY REGARDING THE PERFORMANCE OF THE WORK. ° I o I 4. ALL WORK CARRIED OUT SHALL COMPLY WITH ALL APPLICABLE MUNICIPAL AND UTILITY E COMPANY SPECIFICATIONS AND LOCAL JURISDICTIONAL CODES, ORDINANCES AND APPLICABLE o% _0 I REGULATIONS. v � 5. UNLESS NOTED OTHERWISE, THE WORK SHALL INCLUDE FURNISHING MATERIALS, EQUIPMENT, I APPURTENANCES, AND LABOR NECESSARY TO COMPLETE ALL INSTALLATIONS AS INDICATED ON N .� 04 I UP THE DRAWINGS. -° I v 6. THE SUBCONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH o 0 I MANUFACTURERS RECOMMENDATIONS UNLESS SPECIFICALLY STATED OTHERWISE. L I EXISTING CHURCH ° 0 I BUILDING 7. IF THE SPECIFIED EQUIPMENT CANNOT BE INSTALLED AS SHOWN ON THESE DRAWINGS, THE L I SUBCONTRACTOR SHALL PROPOSE AN ALTERNATIVE INSTALLATION FOR APPROVAL BY THE ° I CONTRACTOR. v, EXISTING AT&T co a EQUIPMENT ROOM I 8. SUBCONTRACTOR SHALL DETERMINE ACTUAL ROUTING OF CONDUIT, POWER AND T1 CABLES, 0 _w IN BASEMENT GROUNDING CABLES AS SHOWN ON THE POWER, GROUNDING AND TELCO PLAN DRAWING. E �`� �'�C SUBCONTRACTOR SHALL UTILIZE EXISTING TRAYS AND/OR SHALL ADD NEW TRAYS AS � EXISTING STEEPLE I ` i� NECESSARY. SUBCONTRACTOR SHALL CONFIRM THE ACTUAL ROUTING WITH THE CONTRACTOR. ° o ABOVE I \` i� ROUTING OF TRENCHING SHALL BE APPROVED BY CONTRACTOR. � •° I i II 9. THE SUBCONTRACTOR SHALL PROTECT EXISTING IMPROVEMENTS, PAVEMENTS, CURBS, LANDSCAPING AND STRUCTURES. ANY DAMAGED PART SHALL BE REPAIRED AT ° .- I �� II J �� SUBCONTRACTOR'S EXPENSE TO THE SATISFACTION OF OWNER. iL__ 0 cu c c NOTE: UP 10. SUBCONTRACTOR SHALL LEGALLY AND PROPERLY DISPOSE OF ALL SCRAP MATERIALS SUCH A LTE ANTENNA AZIMUTHS SHOWN ARE PRELIMINARY AS COAXIAL CABLES AND OTHER ITEMS REMOVED FROM THE EXISTING FACILITY. ANTENNAS 0 REMOVED SHALL BE RETURNED TO THE OWNER'S DESIGNATED LOCATION. AND MAY NOT REFLECT FINAL RF DESIGN. REFER EXISTING STAIR -� TO LATEST RF DATA SHEET FOR FINAL LTE o ANTENNA SPECIFICATIONS, AZIMUTHS, TILTS, ETC. 11 . SUBCONTRACTOR SHALL LEAVE PREMISES IN CLEAN CONDITION. E 1 FULL SCALE 1 /8"=1 '-0" 12. ALL CONCRETE REPAIR WORK SHALL BE DONE IN ACCORDANCE WITH AMERICAN CONCRETE m o NOTES: INSTITUTE (ACI) 301 . o •� 1 . ANTENNA ORIENTATION/AZIMUTHS SHALL BE FIELD VERIFIED. �O3 ROOF PLAN 1 8 o s ,6 FT -4-1 momw 2. EQUIPMENT/ANTENNAS BY OTHERS NOT SHOWN FOR CLARITY. 13. ANY NEW CONCRETE NEEDED FOR THE CONSTRUCTION SHALL HAVE 4000 PSI STRENGTH AT 3. ALL NEW ANTENNAS & RRH S TO BE PAINTED TO MATCH EXISTING ANTENNAS. SCALE: 1 /8"= 1 '-0" A01 HALF SCALE 1 /16"=1 '-0" 28 DAYS UNLESS OTHERWISE SPECIFIED. ALL CONCRETING WORK SHALL BE DONE IN ACCORDANCE WITH ACI 318 CODE REQUIREMENTS. o- LINE OF EXISTING CL INSTALL (2) PROPOSED RRH'S MOUNTED GABLE ROOF BELOW 14. ALL STRUCTURAL STEEL WORK SHALL BE DONE IN ACCORDANCE WITH AISC SPECIFICATIONS. o ON UNISTRUT WITH PROPOSED PIPE MAST,, EXISTING LAND LINK PARABOLIC ANTENNA 15. CONSTRUCTION SHALL COMPLY WITH SPECIFICATION 25736-000-3PS-AOOZ-00001 , (SECTOR A) ,,Q' \ / GENERAL CONSTRUCTION SERVICES. E (SEE DETAIL 1/A04) o� , \ / SWAP (1) AT&T ANTENNA FOR NEW o � 0 16. SUBCONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS AND CONDITIONS PRIOR TO c v — — — / QUINTEL AT&T ANTENNA (SECTOR A) COMMENCING ANY WORK. ALL DIMENSIONS OF EXISTING CONSTRUCTION SHOWN ON THE o t — — / (SEE DETAIL 2&3/AO3) DRAWINGS MUST BE VERIFIED. SUBCONTRACTOR SHALL NOTIFY THE CONTRACTOR OF ANY INSTALL (2) PROPOSED RRH'S DISCREPANCIES PRIOR TO ORDERING MATERIAL OR PROCEEDING WITH CONSTRUCTION. \ I INSTALL (1) RAYCAP DC6 DOME ON PIPE C ° PROPOSEDOPIPENMASTT(SEICTOR C) �� / I I (SEE DETAIL 1/A04 & 1102/AO6) FOR 17 BYESUBCONTRACTOR SHALL NOT DISRUPT COMMERCIAL HE EXISTING ANORMALAOPERATION CONSTRUCTION A Y WORK ON MOUNTING (SEE DETAIL 1116/AO6) � (SEE DETAIL 2/A04) \ / I I EXISTING EQUIPMENT MUST BE COORDINATED WITH CONTRACTOR. ALSO, WORK MAY BE N SCHEDULED FOR AN APPROPRIATE MAINTENANCE WINDOW USUALLY IN LOW TRAFFIC PERIODS AFTER MIDNIGHT. > II / \ II 18. SINCE THE CELL SITE MAY BE ACTIVE, ALL SAFETY PRECAUTIONS MUST BE TAKEN WHEN 0 v SWAP (1 ) AT&T ANTENNA FOR NEW '� _� INSTALL (2) PROPOSED RRH'S MOUNTED WORKING AROUND HIGH LEVELS OF ELECTROMAGNETIC RADIATION. EQUIPMENT SHOULD BE o a� QUINTEL AT&T ANTENNA (SECTOR C} / \ ON UNISTRUT WITH PROPOSED PIPE MAST SHUTDOWN PRIOR TO PERFORMING ANY WORK THAT COULD EXPOSE THE WORKERS TO (SEE DETAIL 2&3/A03) / \ (SECTOR B) (SEE DETAIL 2/AO4) DANGER. PERSONAL RF EXPOSURE MONITORS ARE REQUIRED TO BE WORN TO ALERT OF ANY Imo— SECTOR C / DANGEROUS EXPOSURE LEVELS. 310' / \ ,m \ FULL SCALE 3/8"=1 '-0" 04 -cn C t o o SWAP (1) AT&T ANTENNA FOR NEW 2' 0 2 4 6 Fr DETAIL 100 v o UPPER STEEPLE ANTENNA PLAN 2 v N QUINTEL AT&T ANTENNA (SECTOR B) SCALE: N.T.S. A01 0 SCALE: 3/8" = 1 '-0 A01 (SEE DETAIL 2&3/A03) HALF SCALE 3/16"=1 '-0" L_ ° 0 0 U !V o � at&t BECHTEL ASSOCIATES � p M 0 SITE NAME: m PROFESSIONAL CORPORATION SITE NUMIBER: NYNYNY0801 at&t * 9 ROOF PLAN, ANTENNA PLAN & � RATION LTE-ISSUED FOIR CONSTRUCTION ANA SB RC w o A UNIT OF BECHTEL CORPO 0 04 23/13 w ° ORIENTAL AVENUE AND ETTRICK AVENUE / GENERAL NOTES o, 3 t i 5275 WESTVIEW DRIVE FISHER'S ISLAND, NY 06390 No. DATE REVISIONS BY CHK PP' CFO o 5439 ���� JOB NUMBER DRAWING NUMBER REV a o FREDERICK, MD 21703-8386 USA SCALE: AS NOTED DESIIGNED BY: MG DRAWN BY: MG R0F�S51ON�y 125736-415 T3-NYNYNY0801 - A01 0 0 'L = SIZE 227 54 AHSI ''D U aQ N " s m o EXISTING XFER FEXISTING AC EXISTING AC CONSTRUCTION NOTES SWITCH PANEL PANEL 1 . FIELD VERIFICATION: 0 � SUBCONTRACTOR SHALL FIELD VERIFY SCOPE OF WORK, AT&T ANTENNA PLATFORM 3 LOCATION AND ANTENNAS TO BE REPLACED. v 2. COORDINATION OF WORK: CL c 71 SUBCONTRACTOR SHALL COORDINATE RF WORK AND PROCEDURES WITH CONTRACTOR -�' 0 C. \ / 3. CABLE LADDER RACK: ro ° EXISTING CABLE \/ � SUBCONTRACTOR SHALL FURNISH AND a PORT IN CEILING INSTALL CABLE LADDER RACK, CABLE TRAY, AND / \ CONDUIT AS REQUIRED TO SUPPORT CABLES. oU / \ c _0 �� _ _ �� o1 DETAIL � o m EXISTING DOOR A02 SCALE: N.T.S. � c STRUCTURAL STEEL NOTES 0 -0 ALL 1 AND STEEL WORK SHALL BE PAINTED IN ACCORDANCE WITH THE PROJECT SPECIFICATIONS ACCORDANCE WITH ASTM A36 UNLESS OTHERWISE NOTED. N 1 2. ALL WELDING SHALL BE PERFORMED USING E70XX ELECTRODES AND WELDING CONFORM TO AISC. WHERE FILLET WELD SIZES ARE NOT SHOWN, PROVIDE THE MINIMUM EXISTING SIZE PER TABLE J2.4 IN THE AISC "MANUAL ANUAL OF STEEL CONSTRUCTION". PAINTED C \ LUCENT SURFACES SHALL BE TOUCHED UP. \ CABINET o v EXISTING � 3. BOLTED CONN CL 0 NOKIA ECTIONS SHALL BE ASTM A325 BEARING TYPE E' 24V DC (3/4"0) CONNECTIONS AND SHALL HAVE MINIMUM OF TWO BOLTS UNLESS NOTED C 850 CABINET I o v � � _0 L '— 4. NON—STRUCTURAL CONNECTIONS FOR STEEL GRATING MAY USE 5 8" DIA. A _v / ASTM A 307 U) °- BOLTS UNLESS NOTED OTHERWISE. U ''- C � EXISTING WRITTEN\ 5 INSTALLATION OF CONCRETE EXPANSION/WEDGE ANCHOR, SHALL BE PER MANUFACTURER'S RECOMMENDED PROCEDURE. THE ANCHOR BOLT, DOWEL OR ROD SHALL CONFORM co -a o NOKIA \\ EXISTING TELCO BOARD TO MANUFACTURER'S RECOMMENDATION FOR EMBEDMENT DEPTH OR AS SHOWN ON THE 24V DC EXISTING DRAWINGS. NO REBAR SHALL BE CUT WITHOUT PRIOR CONTRACTOR APPROVAL WHEN \ DRILLING HOLES IN 1900 CABINET RXAIT INSTALL (3) DC CONCRETE. SPECIAL INSPECTIONS, REQUIRED BY GOVERNING SHALL BE PERFORMED IN ORDER TO MAINTAIN MANUFACTURER'S MAXIMUM ALLOWABLE o — RACK CONVERTERS, (1) FIBER LOADS. o MANAGEMENT TRAY, (1) DC SURGE & (1) BBU 6. ALL EXPANSION/WEDGE ANCHORS SHALL BE STAINLESS STEEL OR HOT DIPPED G v ON EXISTING RxAIT RACK THE ANCHOR BOLT GALVANIZED. +, c DOWEL AND ROD SHALL BE STAINLESS ST V WASHERS. EEL WITH STAINLESS STEEL o EXISTING CORDEX 24V 620 DETAIL t v DC POWER PLANT SCALE: N.T.S. U N L m O v- O .c N t v +' .Q v \ 0 0 +- o rn EXISTING EXTERIOR L ACCESS DOOR E � o +' 10'-2" c v, ._ v \ v `~ o o :2 U N\ \\ •� Q \\ 0 N C U j O N\ E � N � N t t I­_ 0) C 0 N N o 0 NOTE: EQUIPMENT ROOM PLAN ULL SCALE 3 )f N � /4 =1 -0 v o PRESENTLY THERE ARE 4 RECTIFIERS, UPON COMPLETION � „ o Z OF LTE UPGRADE, A TOTAL OF 6 RECTIFIERS SHOULD BE SCALE: 3�4"= 1 '-0" �O2 12 0 1 2 3 FT 0 o PRESENT, 2 NEW RECTIFIERS INSTALLED FOR LTE •�' HALF SCALE 3/8".1 '-o" •E -v BECHTEL ASSOCIATES m PROFESSIONAL CORPORATION SITE NAME: FISHERS ISLAND Orr at&t A UNIT OF BECHTEL CORPORATION SITE NUMBER: NYNYNY0801 ,�Q4 co9 0 _ at&t _c C -P - .v' 3 � ' 5275 WESTVIEW DRIVE ORIENTAL AVENUE AND ETTRICK AVENUE '* EQUIPMENT 0- 0 L FREDERICK, MD 21703-8386 USA FISHERS ISLAND, NY 06390 0 04/23/13 LTE-ISSUED FOR CONSTRUCTION ANA SB EC.0 PLAN & NOTES O •c O 439' �' JOB NUMBER U aQ N0. DATE REVISIONS BY CHK `E` AR DRAWING NUMBER REV CALF: AS NOTED DESIGNED BY: MG DRAWN BY: MG °FEsS`oN 25736-415 T3—NYNYNY0801 —A02 0 SIZE 22" x 34" ANSI 'D" V' MECHANICAL DOWN—TILT ASSY. U O O lb � 0 An O ANTENNA INSTALL (1 ) RAYCAP DC6 DOME ON PIPE C MOUNTING HARDWARE TOP OF CROSS (SEE DETAIL 1/A04 & 1102/A06) 0 o (FIT AS REQUIRED) 66.1 ' f A.G.L. FOR MOUNTING (SEE DETAIL 1116/A06) o � Q 0 _,_, SWAP (1) AT&T ANTENNA FOR NEW v QUINTEL AT&T ANTENNA (SECTOR A) INSTALL (2) PROPOSED RRH'S M C- (SEE DETAIL 2&3/AO3) MOUNTED ON UNISTRUT WITH L. 1 0 NEW PANEL PROPOSED PIPE MAST (SECTOR B) 0 a� ANTENNA INSTALL (2) PROPOSED RRH'S MOUNTED (SEE DETAIL 2/AO4) r ON UNISTRUT WITH PROPOSED PIPE MAST o (SECTOR A) (SEE DETAIL 1/A04) SWAP (1 ) AT&T ANTENNA FOR NEW m QUINTEL AT&T ANTENNA (SECTORS B) C ANTENNA MOUNTING PIPE (SEE DETAIL 2&3/AO3 & 2/A04) 3 INSTALL (2) PROPOSED RRH'S MOUNTED E � ON UNISTRUT WITH PROPOSED PIPE MAST L_ (SECTOR C) (SEE DETAIL 2/A04) OPENINGS AND CONCEALMENT TO BE REWORKED AS NECESSARY FOR ° PROPOSED ANTENNAS (ALL SECTORS) 0 Lo C SWAP (1) AT&T ANTENNA FOR NEW i 0 QUINTEL AT&T ANTENNA (SECTOR C) 0 ° (SEE DETAIL 2&3/AO3) v c -° O L JUMPER (S) TO REMOTE RADIO TOP OF LTE AT&T ANTENNA c HEADS (RRHs) 38'-0" f A.G.L. ° (TYP. ALL SECTORS) co u � � I —O a RAD. CENTER OF LTE AT&T ANTENNA L6 K_2_-� 35'-0" f A.G.L. j A NTENNA MOUNTING DETAIL (TYP. ALL SECTORS) v A03 SCALE: N.T.S. r= --------- o � FLOOR �OF UPPER STEEPLE j I • 4'30'-11 f A.G.L. LL ° a 12" 9„ c c I U) 'E I • c I _c 0 O _ 0 jFLOOR OF LOWER STEEPLE i 19,_7"f A.G.L. I I h Will 11 � j m o I o 'c I ° w I _c - I i \ \ I Li Li •a r PROPOSED POWER AND FIBER I FRONT CABLES ALONG EXISTING ROUTE I a IN 2Y2" INNERDUCT I +j io co c s o :p 0 E ° o TO EQUIP. ROOM CLG. v 1 '-7"f A.G.L. v c: ' o EXISTING GRADE tr � u u u mi 0'—O"± A.G.L. C O f o ° EXISTING AT&T EQUIPMENT c I / ROOM IN BASEMENT Q FRONT ELEVATION SIDE VIEW EQUIP. ROOM F.F.E Ji 0 —6'-2"± B.G.L. ° E -0 MECHANICAL CHARACTERISTICS a) ° c WEIGHT: 79lbs (36kg) NOTE: ANTENNA CONFIGURATION WIND LOAD (®150 km/h): (413.4N) AND AZIMUTHS TO BE FIELD VERIFIED. po 'v MAX. WIND SPEED: 150mph (241 .4 km/h) r C FULL SCALE 3/16'9=1 '-0" cn O 3 3 LTE QUINTEL ANTENNA BUILDING ELEVATION 1 4 ° 4 $ 12 FT K" ° z° A03 0 A03 SCALE: N.T.S. SCALE: 3/16"= 1 '-0 HALF SCALE 3/32"=1 '-0" O 0 • o NFL at&t _u o BECHTEL ASSOCIATES SITE NAME: FISHERS ISLAND m � � PROFESSIONAL CORPORATION SITE N U MI BER: NYNYNY0801 ¢ �* '_ � BUILDING ELEVATION & DETAILS a) _ ir _w A UNIT OF BECHTEL CORPORATION 0 04/23/13 LTE ISSUED FOR CONSTRUCTION ANA SB RC w s L i 5275 WESTVIEW DRIVE ORIENTAL AVENUE AND ETTRICK AVENUE tc, zw, v 3 -c FISHERS ISLAND, NY 06390 NO. DATE REVISIONS BY CHK PP' �O �4S439'` �'\ JOB NUMBER DRAWING NUMBER REV CL `o FREDERICK, MD 21703-8386 USA 25736-415 T3-NYNYNY0801 - A03 0 '°RoF SCALE: AS NOTED DESIGNED BY: MG DRAWN BY: MG �$S1°N� o •c — c� a a r A m o A04 o EXISTING L9"x4"x1/2" 3 a (TYP.) , Q PROPOSED 2" DIA STD 11-6" PROPOSED 2" DIA STD 1 —6 — 0 7.5 LONG STEEL PIPE EXISTING L9 x4 x 1/2 7.5 LONG STEEL PIPE MIN.) y 4-1 v (MIN.) (TYP.) (TYP.) MIR.) U O N a c 0 \ O — ud C (D >%_C o m EXISTING STD STEEL EXISTING STD STEEL PIPE PROPOSED 2" DIA STD TYP. PIPE TYP.) (TYP.) 7.5' LONG STEEL PIPE o Q 'vX (TYP.) E ANTENNA CLAMP ANTENNA CLAMP (TYP.) >1 (TYP.) PROPOSED- c: x RRH c c� o PROPOSED QUINTEL PROPOSED „ „ U ANTENNA QUINTEL ANTENNA EXISTING 4x2 :3 _ o WOODEN STUD 0 U 0- 0 0 + o L PROPOSED RRH PROPOSED RRH o O � a _o U 0 � E co EXISTING " � Q � L9 x4 x1 /2 .0 ;y F TYP.) 5" 1 1 /2 o c PROPOSED DC6 c a o (DOME) o o PROPOSED A307 1/2 co -° PROPOSED % DIA BOLT (TYP. 4) 0 RRH N 'o PROPOSED 2" DIA STD CD E y 7.5' LONG STEEL PIPE n o o c �,� y PROPOSED L9"x4"x1/2" „ „ (LLH) (TYP. 2) PROPOSED A307 1/2 DIA PROPOSED L9 x4 x1/2 U—BOLT (TYP. 2) a cn PROPOSED RRH PROPOSED RRH 0 0 a+ ° PROPOSED A307 1/2" ol_ O DIA U—BOLT (TYP. 2) E EXISTING LAG BOLTS c: v /1 B 0 �� OF 318" DIA (TYP.) o z EXISTING L9"x4"x1/2" o -I (TYP. 2) U c ROO F LINE ROOF LINE ROOF LINE v Q \ � = U PROPOSED A307 1/2" z PROPOSED A307 1/2" E -0o DIA U—BOLT (TYP. 2) V DIA U—BOLT (TYP. 2) O v PROPOSED A307 1/2" PROPOSED A307 1/2" -� DIA BOLT (TYP. 4) (TI 4) � DIA BOLT - rn C r � - ELEVATION VIEW ELEVATION VIEW � v co t C ±' � 3 Z RRH & DC6 MOUNTING DETAIL (FOR SECTOR A) RRH MOUNTING DETAIL (FOR SECTOR B&C) 2 SECTION A SECTION e c SCALE: N.T.S. �O4 SCALE: N.T.S. A04 SCALE: N.T.S. A04 SCALE: N.T.S. A04 co � at&t BECHTEL ASSOCIATES ,� of �F . PROFESSIONAL CORPORATION SITE NAME. FISHERS ISLAND ��� 09 , C CD A UNIT OF BECHTEL CORPORATION_w SITE NUMBER: NYNYNY0801 at&t 9 RRH MOUNTING DETAILS rl.t co WESTVIEW DRIVE ORIENTAL AVENUE AND ETTRICK AVENUE 0 04/23/13 LTE-ISSUED FOR CONSTRUCTION ANA SB RIC >.. FREDERICK, MD 21703-8386 USA FISHERS ISLAND, NY 06390 NO. DATE REVISIONS BY CHK PP' op 439 ��'\= JOB NUMBER DRAWING NUMBER REV 1 O ROFES510NP� D *c: scA�E: AS NOTED DESIGNED BY: MG DRAWN BY: MG 25736-415 T3—NYNYNY0801 —A04 0 SIZE 22" r. 34" ANSI 'D' rn t U m � WIDTH 0 C3 Q DC2 RRH C2 GPS ANTENNA DC6—RM Cl FC12 DC2 RRH (PROVIDED BY CONTRACTOR BUILDING OR SHELTER a° °v CANT STRIP &C2 SUB—CONTRAC TOR) TOR )INSTALLED BY D 1 D2 o w BUILDING ROOF OR mU o = FIGURE 1 — TRUNK CABLE TO JUNCTION BOX o — SHELTER ROOF ° r MAXIMUM CABLE LENGTH FOR FIGURE 1 Q a — III � o I v v a III 'I I ' m D 1 LENGTH (FT) 1 1 a TO ANTENNA Cl SIZE C2 SIZE 75 100 125 150 175 200 250 ° ° a a ° ��4 N 7/16"0 HOLE FIBER ALARM (+45 DEGREE) 8AWG 191 166 141 116 91 66 16 d d j j M III— - (2 PLCS) L_ ENTRY CABLE PORT " 8AWG 1OAWG 119 103 88 72 56 41 10 X °3 ° ° a X (0 1/2" COAXIAL CABLE W I I ( 2 ) / / 12AWG 75 65 55 45 36 26 6 7 16 DIN—MALE CONNECTORS _ Ems= v LO O 8AWG = 145 105 65 25 - COAX CABLE 0_ i �- BOLT CPRI-M PRI-S ALM 4-6 / ° N 0 O AISG TX/RX Tx/RX1 ON BOTH ENDS (2 TYP) - ° ° (AS REQUIRED GIGE ALM 1-3 (IF USED 10AWG 10AWG Z 90 65 40 15 — — — BY ANTENNA FOR RET) TO ANTENNA 12AWG 57 41 25 10 — — — MANUFACTURER) o (-45 DEGREE) 8AWG — — — _ _ " -� MOUNT PIPE o TX MON2 0 0 TX MON1 PORT 12AWG 10AWG ° 47 7 — — _ _ _ rl• 1/2" EMBED 2 1/2" 1 3/4 6" & ANGLE CL o GROUND DC ENTRY 12AWG 29 4 — — — — — „ MOUNT PIPE L CABLE C3 MAY BE EITHER 10AWG OR 12AWG. 6 MIN & 1 1/4 0 HOLE o RRH BOTTOM VIEW RRH TOP VIEW LENGTH D3 IS 16 FEET ALL CASES EDGE FRONT ELEVATION L C v v CD RRH SOUTH FACE OF 0 cn C2 SIDE ELEVATION ° CONCRETE C SIZE AND WEIGHT TABLE DC6-RM Cl DOME RRH J \ SHELTER OR BUILDING WALL ° o ° w ° ° HEIGHT W/0 CABLE WEIGHT RRH CID ° RRH WIDTH DEPTH MANAGEMENT COVER W/O BRACKET _ =3 D 1 D2 s RRH 700 MHz 12.2" 10.8" " � 2X40 (80W) 21 51 LBS. FIGURE 2 — TRUNK CABLE TO D (DOME)0 (DOME) o ° � °c 2X40 SOW 12" 9" 25" 43 LBS. Cl DC2 C2 RRH ° 1 1/4.0 HOLE IN MOUNT ,° C ) (W/O SOLAR SHIELD) ANGLE FOR LDF4/FSJ4 c "� COAX CABLE '- �' DC6-RM DC2 RRH SECTION X - X s 0 NOTE: DIMENSIONS INCLUDE MOUNTING BRACKET, SOLAR SHIELD AND CONNECTORS. ° DC2 RRH 0 r o D1 D2 BILL OF MATERIALS a E MINIMUM CLEARANCE TABLE ITEM# DESCRIPTION QUANTITY 00 ° FIGURE 3 — DIRECT CABLE TO DC2 (each) ° •� RRH CABINET CL(INCHES) COMMENTS O.D. x 1 1 1 2"� ,_6" LG. MAXIMUM CABLE LENGTHS FOR FIGURES 2 AND 3 � GALV STEEL PIPE 1 FRONT 36" INSTALLATION ACCESS °- ° ZERO REAR CLEARANCE IS ALLOWED D1/D2 LENGTH (FT) (2� L 3 1/2 X 3 1/2 x 1/4 x 0'-6" LG. 1 0 0 REAR 2" USING GALV STEEL MOUNT ANGLE CL SUPPLIED MOUNTING BRACKETS CABLE 8 AWG 10 AWG 12 AWG HILTI KB TZ 3/8"o W/ 4 1/2" MIN. 2 C Q, RIGHT 4" AIR FLOW Cl 265 165 104 EMB. (GALVANIZED) EXPANSION BOLTS v _T o LEFT 4" AIR FLOW C2 16 16 16 NOTES: c: cn TOP 12" AIR FLOW 1 . LOCATION OF ANTENNA MUST ° HAVE CLEAR VIEW OF SOUTHERN SKY AND CANNOT HAVE ANY ° BOTTOM 12" CONDUIT ROUTING NOTES: BLOCKAGES EXCEEDING 25% OF THE SURFACE AREA OF A HEMISPHERE AROUND THE GPS ANTENNA. v - 1 . CABLES LENGTHS ARE APPLICABLE FOR ALU 70OMHZ & AWS FREQUENCY c o RRH MODELS. 2. ALL GPS ANTENNA LOCATIONS ABLE TO RECEIVE CLEAR SIGNALS FROM A MINIMUM OF FOUR (4) SATELLITES. VERIFY WITH HANDHELD GPS BEFORE FINAL LOCATION OF GPS ANTENNA. 1- ALCATEL—LUCENT 9442 1- 2. NOMINAL SYSTEM VOLTAGE IS -48V DC, SUPPLIED FROM A 48V BATTERY. oa REMOTE RADIO HEAD (RRH) NORMAL OPERATING VOLTAGE IS 52V. E911 — GPS ANTENNA C > 3. CABLE LENGTHS BASED ON ROSENBERGER CABLES. WALL MOUNTING DETAIL FOR NEW BUILD E o o v v L I— v1 C � C N ALCATEL-LUCENT 9442 REMOTE RADIO HEAD (RRH) ril o LTE CONDUCTOR SIZES 408 E911 -GP S ANTENNA MOUNTING DETAIL 1 3 SCALE: N.T.S. A05 SCALE: N.T.S. A05 SCALE: �O5 0 �" N.T.S.S. v Z 0 a . L C 0 0 U •N ° s E � U Z BECHTEL ASSOCIATES SITE NAME: FISHERS ISLAND ,� °� NE� at&t m ° co PROFESSIONAL CORPORATION ,�� � M 0 ° SITE NUMBER: NYNYNY0801 * s ° 'A REMOTE RADIO HEAD (RRH) MOUNTING, LTE ._t L A UNIT OF BECHTEL CORPORATION CONDUCTOR SIZES & GPS UNIT MOUNTING m 3 _ 5275 WESTVIEW DRIVE ORIENTAL AVENUE AND ETTRICK AVENUE 0 04/23/13 LTE-ISSUED FOR CONSTRUCTION ANA SB RC c v) FISHERS ISLAND NY 06390 �' u DETAILS >' OL •L FREDERICK, MD 21703-8386 USA ' NO. DATE REVISIONS BY CHK PP' '4`Q a S�3g-� ,L��'� JOB NUMBER DRAWING NUMBER REV 0 " pR�Fess�oNPy U QQ SCALE: AS NOTED DESIGNED BY: MG DRAWN BY: MG 25736-415 T3—NYNYNY0801 —A05 0 "D SIZE _ x 34' AIJSI 3.50" s —DOME COVER M % SECURING BAND o Al R VALVE Q co v v RAYCAP DC6 CL c OVER VOLTAGE PROTECTOR -All I -- ° WITH DOME COVER s v u a M 1 0 U TOP VIEW 9.25" ° m 9.00" a MIN. 2" TO MAX. 4" ° OVERAVOLTAGE GALVANIZED PIPE o 40-j PROTECTOR T ro DOME COVER DOME SECURING o L BAND N C N IE= 00 CD - - U +' t -° o O U u') o —CLIP FOR ATTACHING DC6 (OVP) TO BASE ° RAYCAP SUPPLIED o ASSEMBLY (TYP) r� POLE MOUNTING BRACKETS o N a DOME COVER o co 0 RAYCAP SUPPLIED SECURING BAND N E SECURING BAND FOR RAYCAP SUPPLIED ° ATTACHING DOME BASE ASSEMBLY o COVER TO DC6 OVER ° -v VOLTAGE PROTECTOR ---- POWER CABLE INGRESS PORTS o c CLIP LUGS FOR ATTACHING 4-j -° DEVICE TO BASE ASSEMBLY FIBER CABLE OVAL CABLE TIE BAR .N ° INGRESS PORTS C; 0 FIBER JUMPER (5) 1 .57"f 12.38" o (NOTE 1) a� a� E 9.56" NOTES: Ill o SIDE VIEW WEIGHT = 32.8lbs (EACH) 1 . RAYCAP VIA AT&T SUPPLIES THE DC6 OVER VOLTAGE PROTECTOR AND PIPE o •� DC6-48-60- 18-81F MOUNTING BRACKETS. SUBCONTRACTOR SHALL SUPPLY THE PIPE. " ° 10.38 (12 PFD) FIBER (6 PR) FIBER a co TRUNK INGRESS TRUNK INGRESS OPTIONAL ONE-HOLE RAYCAP DC6-48-60- 18-8F Q o GASKET FOR 18 PR FIBER CLOSE TRUNK CABLE NOT SHOWN DC POWER OVER VOLTAGE PROTECTOR (OVP) o � PORT FIBER JUMPER (4) o FIBER JUMPER (4) POLE MOUNT BASE ASSEMBLY v •c E s FIBER JUMPER (5) ° FIBER JUMPER (5 o -� v I / ® O O ® FIBER SIDE QUANTITY OF HOLES _c IN GASKET (TYP) ">• o°o / ® oo POWER SIDE oo ® oo POWER SIDE o DC JUMPERS DC JUMPERS DC POWER OVER VOLTAGE PROTECTOR OVP c 0 DC JUMPERS ° DC JUMPERS o 0 CLIP LUGS FOR ° DOME COVER CLIP LUGS FOR ° DOME COVER POLE MOUNT BASE ASSEMBLY rll16 ATTACHING DEVICE SECURING BAND �O6 v �3 ATTACHING DEVICE SECURING BAND TO BASE ASSEMBLY SCALE: N.T.S. a TO BASE ASSEMBLY o (TYP 4) CLOSE ALARM (TYP 4) OPTION DC TRUNK ALARM U > DC TRUNK PORT 0 PORT o (TYP 5) INGRESS PORT INGRESS PORT NOTES: BOTTOM VIEW BOTTOM VIEW ° 1 . REMOVE CABLE SEALING GLAND AND s +' DC6-48-60-0-8F DC6-48-60- 18-8F INSTALL M320 .5 METRIC-TO-1 " NPT ~ RAYCAP DC6-48-6 0- 18-8F AND ADAPTER (COOPER CROUSE-HINES P/N CAP 740 994 OR EQUIVALENT MFR) o RAYCAP DC6-48-60-0-8F WHEN CONNECTING CONDUIT TO OVP. N co 3 DC POWER OVER VOLTAGE PROTECTOR (OVPJ 0 z DC POWER SURGE PROTECTION 102 0 c SCALE: N.T.S. A06 •� oQEw at&t BECHTEL ASSOCIATES SITE NAME: FISHERS ISLAND �Q cow o Ill cn PROFESSIONAL CORPORATION c a) SITE NUMBER: NYNYNY0801 9 Dc POWER SURGE PROTECTION & o a $C C r w DC POWER (OVP) POLE MOUNTING DETAILS O +, A UNIT OF BECHTEL CORPORATION 0 04/23/13 LTE-ISSUED FOR CONSTRUCTION ANA SB R n -t U) ORIENTAL AVENUE AND ETTRICK AVENUE `� o, i 5275 WESTVIEW DRIVE FISHERS ISLAND, NY 06390 NO. DATE REVISIONS BY CHK PP' `'E`Q 439'x' kt'\? JOB NUMBER DRAWING NUMBER REV CLo FREDERICK, MD 21703-8386 USA 25736-415 T3-NYNYNY0801 -A06 0 L SCALE: AS NOTED DESIGNED BY: MG DRAWN BY: MG R�FESS�oNP� U aQ SIZE ??" x 34' A�iSi D„ N " U O 0° NOTES: o 1 . FURNISHED BY ALU/AT&T. 3 a LTE ANTENNA LTE ANTENNA LTE ANTENNA 2. INSTALLED BY ALU OR AS SCOPED BY MARKET. AISG CABLE FOR � WITH RET WITH RET WITH RET 3. FURNISHED BY BECHTEL. v RET CONTROL NOTES: 3, 4 NOTES: 3, 4 NOTES: 3, 4 4. INSTALLED BY BECHTEL. a v NOTES: 3, 4, 24 5. FINAL CONNECTION BY ALU OR AS SCOPED BY MARKET. ° (TYP FOR 3) 6. OPEN END OF CONDUIT TO BE LEFT WEATHERPROOFED UNTIL TERMINATED. s ° 7. ARGUS 053-997-20-0000 DUAL FEED DC-DC CONVERTER WITH 012-526-20-040 2KW MODULES. a) oa 8. PART OF CONVERTER WITH 18 BREAKER POSITIONS. BREAKERS SPECIFIED SEPARATELY. M v COAX JUMPERS 9. BREAKERS TO BE TAGGED AND LOCKED OUT. 10. SIAD IS FURNISHED AND INSTALLED BY OTHERS AND INCLUDES POWER CONNECTIONS AND FIBER TO NOTES: 3, 4, 13 THE NETWORK INTERFACE DEVICE. WHEN IN BECHTEL SCOPE, INSTALL 10 AWG CHASSIS GROUND, 2 COUNT, SINGLE PROVIDE (2) 1 O BREAKERS FROM A 24V DC POWER SOURCE OR (2) 5A BREAKERS FROM A 48V v m MODE FIBER CABLE DC POWER SOURCE AND CONNECT USING MFR POWER CABLE WITH SPECIAL CONNECTOR. v NOTES: 3, 4, 5, 13, 25 1900 OR 1900 OR 1900 OR 11 . DELETED 0 700 RRH 700 RRH 700 RRH 12. LEC TO FURNISH AND INSTALL NETWORK INTERFACE DEVICE. 0 3 (TYP FOR 6) NOTES: AWS RRH MOTES: AWS RRH NOTES: AWS RRH 13. LEAVE COILED AND PROTECTED UNTIL TERMINATED. E 1 , 2, 5 NOTES: 1 , 2, 5 NOTES: 1 , 2, 5 NOTES: 14. SEE DETAIL 1408 FOR FOR DC POWER CABLE SIZES. 0 2/C DC CABLES 1 , 2, 5 1 , 2, 5 1 , 2, 5 15. FIBER AND POWER DISTRIBUTION BOX W/48V DC SURGE SHALL BE RAYCAP MODEL NOTES: 3, 4, 5, 13, 14 v � (TYP FOR 6) 6 AWG DC2-48-60-0-9E. N , 16. DC SURGE SHELF SHALL BE RAYCAP DC6-48-60-RM. SEE DETAIL 1409 FOR INTERNAL WIRING •� 1 " LFMC ��_ �_ �� �_ ' (TYP FOR 6) DIAGRAM. o NOTES: 3. 4, 6, 21 Q - - (NOTE 13) 17. FIBER AND POWER DISTRIBUTION BOX SHALL BE RAYCAP FC-12-PC6-10E. : (TYP FOR 6) 0 Q - 0 Q 0 r& Q - 18. SEE DETAIL 1411 FOR INTERNAL WIRING DIAGRAM. 19. SEE DETAIL 1417 FOR INTERNAL WIRING DIAGRAM. 0 ALARM CABLE 20. SUPPORT FIBER & DC POWER CABLES WITH SNAP-IN HANGERS SPACED NO GREATER THAN 3 FEET ° NOTES: 3 4, 5 APART ON TOWER. SUPPORT FIBER AND DC POWER CABLES INSIDE MONOPOLE WITH CABLE , FIBER & POWER DISTRIBUTION FIBER & POWER DISTRIBUTION FIBER & POWER DISTRIBUTION HOISTING GRIPS AT 250 FT MAXIMUM INTERVALS. DRESS CABLES TO PREVENT CONTACT WITH o (TYP FOR 3) BOX W/48VDC SURGE BOX W/48VDC SURGE BOX W/48VDC SURGE ENTRANCE AND EXIT OPENINGS. -o (RAYCAP DC2-48-60-0-9E) (RAYCAP DC2-48-60-0-9E) (RAYCAP DC2-48-60-0-9E) 21 . CONDUIT TO BE USED ON A TOWER IF THE RRH IS MORE THAN 10' FROM THE DISTRIBUTION UNIT. N a. 2" FLEXIBLE CONDUIT NOTES: 3, 4, 15 & 18 i NOTES: 3, 4, 15 & 18 i NOTES: 3, 4, 15 & 18 6 AWG MAXIMUM CABLE LENGTH IS 16 FEET. 0 _w NOTES: 3, 4 (TYP FOR 3) 22. SINGLE-CONDUCTOR DC POWER CABLES SHALL BE TELCOFLEXO OR KS241947, COPPER, UL LISTED -° (TYP OF 3) RHH NONI-HALOGEN, LOW SMOKE WITH BRAIDED COVER, TYPE TIC (1/0 AND LARGER). UNLESS E - - - OTHERWISE NOTED, STRANDING SHALL BE CLASS B (TYPE III) FOR CABLES SIZES 14, 12 & 10 0 o (2) 2/C DC CABLES m AWG AND CLASS I (TYPE IV) FOR SIZES 8 AWG AND LARGER. CABLES SHALL BE COLOR CODED = v NOTES: 3, 4, 14 RED FOR +24V, BLUE FOR -48V AND GRAY FOR 24V AND 48V RETURN CONDUCTORS. •T (TYP FOR 3) FIBER FIBER MULTI-CONDUCTOR DC POWER CABLES SHALL BE COPPER, CLASS B STRANDING WITH FLAME (2) 2 COUNT, SINGLE RETARDANT PVC JACKET, TYPE TC, UL LISTED FOR 90-C DRY/ 75-C WET INSTALLATION. 0 c:•- MODE FIBER CABLE DISTRIBUTION UNIT 23. GROUNDING WIRES SHALL BE COPPER, THHN/THWN UL LISTED FOR 90'C DRY/75'C WET 0 NOTES: 3, 4 0 AT&T ANTENNA HEIGHT INSTALLATION. MINIMUM SIZE IS 6 AWG UNLESS NOTED OTHERWISE. v (TYP FOR 6) (RAYCAP FC12-PC6-1 OE) 24. RET CONTROL FROM THE RRH IS AN OPTIONAL METHOD OF CONNECTION. REFER TO RF DATA SHEET ' 6 AWG TOWER/ROOFTOP FOR APPLICABILITY. 0 2 1/2- CONDUIT NOTE: 19 ' 25. FIBER OPTIC CABLES SHALL BE INSTALLED IN FLEXIBLE CONDUIT AS SCOPED BY MARKET. (EXCEPT TOWER SITES) 26. MAXIMUM 4/0 AWG CABLE LENGTH FROM 24V DC POWER PLANT TO CONVERTER SHALL NOT EXCEED +' NOTES: 3, 4, 20 - o - - - - - - - - - - - - - - - - - - - - - - - - _- - - - - - - - - - - - - - - - - - - - - 44 FT. _ 12 COUNT, SINGLE MODE FIBER CABLE ALCATEL-LUCENT EQUIPMENT LOCATED 27. SEE DETAIL 1505 FOR GPS ANTENNA AND SURGE SUPPRESSOR COAXIAL CABLE CONNECTION. Ill o 6/C DC CABLES FIBER IN 2" FLEXIBLE CONDUIT/INTERDUCT 9412 CABINET W/2 AT GROUND LEVEL 28• SEE DETAIL 1150C FOR ALARM CABLE REQUIREMENTS. o NOTES: 3, 4, 14 W/ 1 1/2- REDUCER 9926 (BBU) �� (TYP FOR 2) FIBER NOTES: 3,4 , 5, 6 NOTES: 1 , 2, 5 MGMT TRAY FIBER FIBER a � DC SURGE SHELF CL 700 MHz AWS 0 0, NOTES: 3, 4, 16 LTE BBU LTE BBU 6 AWG NOTES: 1 , 2, 5 NOTES: 1 , 2, 5 E - v 4-' 6 AWG 6 AWG o (12) 1/C 12 AWG - - _ NOTES: 3, 4 (2) 1/C 1 AWG - (2) 2AWG GPS ANTENNA & 0 CLASS B IN 1 1/2" SURGE SUPPRESSORS 48V DC BREAKER PANEL LFMC CONDUIT NOTES: 3, 4, 27 � z (1) 100A & NOTES:: 3, 4, 5, 6 (2) 4/0 AWG 2 COUNT, SINGLE MODE FIBER CABLE 0 " 6 15A BREAKERS A M CABLE 2 1/2 IMC/RNC ( ) LAR NOTES: 1 , 2, 5 (TYP FOR 2) C- CONDUIT NOTES: 3, 4, 8, 9 NOTES: 1 , 2, 5 66 BLOCK SIAD 'v Q NOTES 3, 4, 26 NOTE: 10 1 " LFNC CONDUIT � ^ (TYP FOR 2) -- -- --_ ------- NOTES: 3, 4 i (W/ PULL STRING) SYSTEM DIAGRAM, TOWER/ROOFTOP SITE F 0 - --� (ALARM. CABLES I � NOTES. 3, 4, 6 WITH OUTDOOR BASE BAND ON GRADE v 2CON ERTERV MIOTES. 3, 4, 28 I _ AND RRH 'S ON TOWERZROOFTOP BREAKERS OIN W/ 2KW MODULES 24V DC POWER NOTES: 3, 4, 7 - BY OTHERS-/ NETWORK INTERFACE DEVICE DETAIL r140 A Q ,o -0 PLANT (VARIES BY MARKET) 0 0 NOTE: 12 , SCALE: N.T.S. E01 N OUTDOOR CABINET - ' 03 2AWG 6AWG 2AWG o 0 CHASSIS GND - 0 CL O O U •cn cn f NS • ��o p at&t BECHTEL ASSOCIATES SITE NAME: FISHERS ISLAND m N PROFESSIONAL CORPORATION . G o�,o v 0 PROFESS SITE NUMBER: NYNYNY0801 at&t * s * SYSTEM DIAGRAM o aD L. L CORPORATION _ N A UNIT OF BECHTEL ORIENTAL AVENUE AND ETTRICK AVENUE 0 04/23/13 LTE ISSUED FOiR CONSTRUCTION ANA s6 RC o, 3 t 5275 WESTVIEW DRIVE FISHER'S ISLAND, NY 06390 NO. DATE REVISIONS BY CHK PPT 04 39 ��'�= JOB NUMBER DRAWING NUMBER REV AWPI•; cn 700 1900 OR AWS -1 .� SECTOR A SECTOR A _c - 018 (2) 1 AWG 1/C °0 � POWER CABLES 6/C 8 AWG POWER CABLES _ o c ALCATEL-LUCENT r o T 0 o a! o 3 a 9412 CABINET W/2 48V DC + I I 3 o- UJI c 0 uj Ix > 9926 (BBU) INPUT - f ' _J Z U m g Z U m Q ° v L--- c� o w a c� o �- _ _ —_ v NOTE 12 I + I + I + I + I + I + (NOTE 11) (NOTE 11) + - ❑ ❑ + - ❑ o ALARM o 0 0 0 0 o cn cn cn cn cn cn JUNCTION BOX 2/C POWER CABLES eAM 700 00 00 00 3 3 3 3 3 3 (NOTE 14) (6 TYP) (NOTE 6) JACKS ALARM � rl r- P, �` ^ a a a a a a SEE NOTE 13 (TYP) � 0 CABLE as mm 66 aal mm ou ALCATEL-LUCENT + x ,, 9926 (BBU) 48V DC _ vo o m 700MHz INPUT _ m C Ali � ALARM cDC SURGE SHELF RAYCAP DC6-RM (NOTES 2, 8) 6 AWG �� 6 AWG � ° JACKS - ALARM - 0 3 FIBER PORTS GND - + - + - + - + - + - + JUNCTION BOX TO GROUND CABLE TO GROUND E ; 1 2 3 4 5 5 T1 RJ45 WHEN REQUIRED _ --1 0 -0 ❑ ❑ ❑ ❑ ❑ ❑ JACKS SEE 13 (NOTE 9) 1900 OR AWS 700 co , ( (3 TYP) I I ro I I SECTOR B SECTOR B v Lo �- 6 AWG I I ALARM N _ •� eAM 1900 OR AWS JACKS L- - -J TO EQUIP. NC 0 a ° CABINET C o o -00 o ALCATEL-LUCENT GROUND 3 3 m a o 9926 (BBU) 48V DC + BAR A-AWS+ + + Z v m g 0 v m g 1900 OR AWS INPUT _ _ (12) 1/C 12 AWG A-AWS- 0 o li a c� o � a 0 o ALARM 0 POWER CABLES + + + ° JACKS A-700+ p ❑ 7+ - ❑ ❑ FIBER PORTS GND A-700- _ _ a 1 2 3 4 5 6 T1 RJ45 B-AWS+ FIBER & POWER 0 o a a a a a a + + r----� ' ❑ ❑ ❑ ❑ ❑ D JACKS 0 0 0 0 DISTRIBUTION +, B-AWS- ' N r r r — B-700+ + 48V SURGE IT PROTECTION + I I _ E B-700- R�AYCAP DC6 _ � o -48V C-AWS+ (NOTE 7) + e ° -v + 6 AWG �`� 6 AWG SUPPORT � , � 4 1 C 4 0 AWG C-AWS- _ _ - - 4, PO / / C-700+ + + TO GROUND TO GROUND 0 ° STAND POWER CABLES OV C-700- _ El _w ._ zl : K o � 2 AWG - +24V INPUT +24V INPUT 1900 OR AWS ° c 700 — � o TO FEED A FEED B (NOTE 3) 24V TO -48V CONVERTER SECTOR C SECTOR C WITH +, o GROUND (NOTE 3) INTEGRAL -48V BREAKER PANEL v (NOTE 2) 2 AWG o v M c - I FACTORY v TO r- --� � o � w o � E WIRING ALARM ALARM CABLE GROUND I I 3 � � m o TERMINAL 1 TO 66 BLOCK I I o w o w ir OV BLOCK THIS SHEET I 1 o °-,,L° a o LL_ a o •- +GND 0/P (NOTE 4) (NOTE 3) ( ) �� • • - GND I/P ' L- -J + - ❑ ❑ + - ❑ ❑ INSTALL (2) (N) 250A BREAKERS 6 AWG a o 24V 2 AWG �- (NOTE 5) (+} (NOTE 10) - - TO EQUIP. CABINET 6 AWG 0 0, a '�= GND BAR 6 AWG NOTES ° cn 1 . LABEL THE DC POWER CABLES AT BOTH ENDS OF EVERY WIRE AND IN ANY PULL BOX IF USED. LABEL SHALL BE DURABLE, SELF ADHESIVE, TO GROUND TO GROUND WRAPPED LONGITUDINALILY ALONG THE CABLE AND STATE THE SECTOR, FREQUENCY BAND AND POLARITY; I.E. "A-AWS+". 2. INSTALL IN AUXILIARY EQUIPMENT CABINET. ' 3. CABLE TERMINALS FOR +24V INPUT FEED A, FEED B AND REFERENCE GROUND SHALL BE 2-HOLE: 3/8" ON 1" CENTER. " WIRING DIAGRAM , 0 UTD 00 R PART OF DC POWER PLANT 4. INSTALL CABLE TERMINALS FOR FEED A AND FEED B RETURN BACK-TO-BACK ON OPPOSITE SIDES OF PAD USING 1 -HOLE 3/8 TERMINALS. o : _ 5. CABLE TERMINALS FOR CHASSIS GROUND SHALL BE 2-HOLE, 1/4 ON 5/8 CENTER. BASE BAND AND R R H s O N TOWER R 0 0 0 CRGB 6. SEE DETAIL 1408 FOR DC POWER CABLE SIZES AND MAXIMUM LENGTH. DC/DC CONVERTER, DC6 0 Q 7. SEE DETAIL 1410 FOR DC6 INTERNAL WIRING. CABLE GROUND WIRES NOT SHOWN FOR CLARITY. v _ 8. SEE DETAIL 1409 FOR DC6-RM INTERNAL WIRING. ° 9. A JUNCTION BOX IS REQUIRED WHEN FIBER OPTIC CABLES ARE INSTALLED IN CONDUIT AS SCOPED BY MARKET. ° 0 10. CONVERTER REFERENCE GROUND IS NOT REQUIRED WHEN CONVERTER AND 24V DC POWER PLANT ARE ON THE SAME RACK OR ENCLOSURE. E 0 11. THE BARE WIRE OF EACH MULTI-CONDUCTOR CABLE AND DRAIN WIRE WHEN A SHIELDED CABLE IS USED, SHALL BE CONNECTED TO THE +; EQUIPMENT CABINET GROUND BAR. v 12. SEE ALARM BLOCK ASSIGNMENT DETAIL FOR ALARM CABLE CONNECTIONS. 13. WHEN A 1900 RRH IS USED INSTEAD OF AN AWS RRH CABLE LABELS SHOULD REFLECT CORRECT FREQUENCY BAND. 14. PROVIDE A JUNCTION BIOX, AS SCOPED BY MARKET, TO COIL EXCESS DC POWER AND OPTICAL FIBER CABLES. (FIBER CABLES NOT SHOWN rli FOR CLARITY.) v Q ° DETAIL 1 41 0 3 SCALE: N.T.S. E02 v 0 � z 0 CL L J� • Ov: NEw at&t BECHTEL ASSOCIATES ° o O a? RRH WIRING DIAGRAM � SITE NAME: FISHERS ISLAND '� �`' 9 m PROFESSIONAL CORPORATION at&t IoN SITE NUMIBER: NYNYNY0801 * .s o �, A UNIT OF BECHTEL CORPORAT ORIENTAL AVENUE AND ETTRICK AVENUE 0 04/23/13 LTE-ISSUED FOR CONSTRUCTION ANA se RC co L- +' i 5275 WESTVIEW DRIVE N0. DATE REVISIONS BY CHK PP' �'F© 43g-� ? JOB NUMBER DRAWING NUMBER REV FISHERS ISLAND, NY 06390 FREDERICK, MD 21703-8386 USA AROFEsw NPR 25736-415 T3-NYNYNY0801 -E02 0 CL o SCALE: AS NOTED DESIGNED BY: MG DRAWN BY: MG U aQ �,i �izE 22„ 34" Ai�i "�, SYMBOLS ELECTRICAL INSTALLATION NOTES (AS APPLICABLE) S/G SOLID GROUND BUS BAR M ° 1 . WIRING, RACEWAY, AND SUPPORT METHODS AND MATERIALS SHALL COMPLY WITH THE REQUIREMENTS 23. CABINETS, BOXES, AND WIREWAYS SHALL BE LISTED OR LABELED FOR ELECTRICAL USE IN ACCORDANCE OF THE NEC AND TELCORDIA. WITH NEMA, UL, ANSI/IEEE, AND NEC. S/N SOLID NEUTRAL BUS BAR a 2. SUBCONTRACTOR SHALL MODIFY EXISTING CABLE TRAY SYSTEM AS REQUIRED TO SUPPORT RF AND 24. CABINETS, BOXES, AND WIREWAYS TO MATCH THE EXISTING INSTALLATION WHERE POSSIBLE. SUPPLEMENTAL GROUND CONDUCTOR Fm TRANSPORT CABLING TO THE NEW BTS EQUIPMENT. SUBCONTRACTOR SHALL SUBMIT MODIFICATIONS TO CONTRACTOR FOR APPROVAL. 25. WIREWAYS SHALL BE EPDXY-COATED (GRAY) AND INCLUDE A HINGED COVER, DESIGNED TO SWING OPEN o0 2-POLE THERMAL-MAGNETIC o ° DOWNWARD; SHALL BE PANDUIT TYPE E (OR EQUAL); AND RATED NEMA 1 (OR BETTER) INDOORS, OR NEMA ° CIRCUIT BREAKER 3. ALL CIRCUITS SHALL BE SEGREGATED AND MAINTAIN MINIMUM CABLE SEPARATION AS REQUIRED BY _ 0 3R (OR BETTER) OUTDOORS. °' +' THE NEC AND TELCORDIA. SINGLE-POLE THERMAL-MAGNETIC 0 0 26. EQUIPMENT CABINETS, TERMINAL BOXES, JUNCTION BOXES, AND PULL BOXES SHALL BE GALVANIZED OR ° ° CIRCUIT BREAKER °' a- m 4. CABLES SHALL NOT BE ROUTED THROUGH LADDER-STYLE CABLE TRAY RUNGS. EPDXY-COATED SHEET STEEL SHALL MEET OR EXCEED UL 50, AND RATED NEMA 1 (OR BETTER) INDOORS, 0 e CHEMICAL GROUND ROD 0 a� 5. EACH END OF EVERY POWER, GROUNDING, AND T1 CONDUCTOR AND CABLE SHALL BE LABELED WITH COLOR- OR NEMA 3R (OR BETTER) OUTDOORS CODED INSULATION OR ELECTRICAL TAPE (3M BRAND, 1 /2 INCH PLASTIC ELECTRICAL TAPE WITH UV ® GROUND ROD 27. METAL RECEPTACLE, SWITCH, AND DEVICE BOXES SHALL BE GALVANIZED, EPDXY-COATED, OR NON- o m PROTECTION, OR EQUAL). THE IDENTIFICATION METHOD SHALL CONFORM WITH NEC & OSHA, AND MATCH CORRODING; SHALL MEET OR EXCEED UL 514A AND NEMA OS 1 ; AND RATED NEMA 1 (OR BETTER) � DISCONNECT SWITCH >% EXISTING INSTALLATION REQUIREMENTS. INDOORS, OR WEATHER PROTECTED (WP OR BETTER) OUTDOORS. METER O v 3 6. POWER PHASE CONDUCTORS (I.E., HOTS) SHALL BE LABELED WITH COLOR-CODED INSULATION OR 28. NONMETALLIC RECEPTACLE, SWITCH, AND DEVICE BOXES SHALL MEET OR EXCEED NEMA OS 2; AND E 0 ELECTRICAL TAPE (3M BRAND, lh INCH PLASTIC ELECTRICAL TAPE WITH UV PROTECTION, OR EQUAL). PHASE RATED NEMA 1 (OR BETTER) INDOORS, OR WEATHER PROTECTED (WP OR BETTER) OUTDOORS. ° CONDUCTOR COLOR CODES SHALL CONFORM WITH THE NEC & OSHA AND MATCH EXISTING INSTALLATION ■ CADWELD TYPE CONNECTION REQUIREMENTS. 29. THE SUBCONTRACTOR SHALL NOTIFY AND OBTAIN NECESSARY AUTHORIZATION FROM THE CONTRACTOR COMPRESSION TYPE CONNECTION 0 0 BEFORE COMMENCING WORK ON THE AC POWER DISTRIBUTION PANELS. c `V 7. ALL ELECTRICAL COMPONENTS SHALL BE CLEARLY LABELED WITH ENGRAVED LAMACOID PLASTIC LABELS. .1 ALL EQUIPMENT SHALL BE LABELED WITH THEIR VOLTAGE RATING, PHASE CONFIGURATION, WIRE 30. THE SUBCONTRACTOR SHALL PROVIDE NECESSARY TAGGING ON THE BREAKERS, CABLES AND ---- GROUNDING WIRE a� CONFIGURATION, POWER OR AMPACITY RATING, AND BRANCH CIRCUIT ID NUMBERS (I.E., PANELBOARD AND DISTRIBUTION PANELS IN ACCORDANCE WITH THE APPLICABLE CODES AND STANDARDS TO SAFEGUARD .0 o CIRCUIT ID'S). AGAINST LIFE AND PROPERTY. 0 U 0° 8. PANELBOARDS ID NUMBERS AND INTERNAL CIRCUIT BREAKERS (CIRCUIT ID NUMBERS) SHALL BE ABBREVIATIONS CLEARLY LABELED WITH ENGRAVED LAMACOID PLASTIC LABELS. DETAIL AGL ABOVE GRADE LEVEL " c 115 o v -o L 9. ALL TIE WRAPS WHERE PERMITTED SHALL BE CUT FLUSH WITH APPROVED CUTTING TOOL TO REMOVE SHARP �O3 SCALE: N.T.S. AWG AMERICAN WIRE GAUGE o as EDGES. USE LOW PROFILES TIE WRAPS. BCW BARE COPPER WIRE 0 - 10. POWER, CONTROL, AND EQUIPMENT GROUND WIRING IN TUBING OR CONDUIT SHALL K SINGLE CONDUCTOR -° E (12 AWG OR LARGER), 600 V, OIL RESISTANT THHN OR THWN-2, CLASS B STRANDED COPPER CABLE RATED BTS BASE TRANSCEIVER STATION o FOR 90 'C (WET AND DRY) OPERATION; LISTED OR LABELED FOR THE LOCATION AND RACEWAY SYSTEM USED, TRANSIENT VOLTAGE SURGE SUPPRESSION (TVSS) (E) EXISTING co v UNLESS OTHERWISE SPECIFIED. EG EQUIPMENT GROUND -0 = w 11 . SUPPLEMENTAL EQUIPMENT GROUND WIRING LOCATED INDOORS SHALL BE SINGLE CONDUCTOR (6 AWG OR 1 . RF TVSS DEVICES SHALL BE INSTALLED IN ALL NEW ANTENNA & NEW COAXIAL INSTALLATION OR EGR EXTERNAL GROUND RING ° .� LARGER), 600 V, OIL RESISTANT THHN OR THWN-2 GREEN INSULATION, CLASS B STRANDED COPPER CABLE REPLACEMENTS. o RATED FOR 90 'C (WET AND DRY) OPERATION; LISTED OR LABELED FOR THE LOCATION AND RACEWAY SYSTEM EMT ELECTRICAL METALLIC TUBING c USED, UNLESS OTHERWISE SPECIFIED. 2. SEE DETAIL 116 AND 124 FOR ADDITIONAL RF COAXIAL TVSS REQUIREMENTS. GEC GROUNDING ELECTRODE CONNECTION � v C7 12. SUPPLEMENTAL EQUIPMENT GROUND WIRING LOCATED OUTDOORS, OR BELOW GRADE, SHALL BE SINGLE 3. AC TVSS DEVICES FOR AC POWER SHALL BE INSTALLED FOR ALL NEW AC PANEL INSTALLATION OR GEN GENERATOR CONDUCTOR 2 AWG SOLID TINNED COPPER CABLE, UNLESS OTHERWISE SPECIFIED. REPLACEMENTS GRC GALVANIZED RIGID CONDUIT 0 13. POWER WIRING, NOT IN TUBING OR CONDUIT, SHALL BE MULTI-CONDUCTOR, TYPE TC CABLE (12 AWG OR 4. THE AC TVSS SHALL BE COMMON MODE TYPE, MINIMUM RATED 120kA SURGE CURRENT, AND HAVE IGR INTERNAL GROUND RING (HALO) _r a E LARGER), 600 V, OIL RESISTANT THHN OR THWN-2, CLASS B STRANDED COPPER CABLE RATED FOR 90 'C (WET MONITORING LIGHTS WITH FORM C ALARM CONTACTS. THE AC TVSS SHALL BE INNOVATIVE TECHNOLOGIES 0° ° AND DRY) OPERATION; WITH OUTER JACKET; LISTED OR LABELED FOR THE LOCATION USED, UNLESS ZE PTX120 OR OWNER APPROVED EQUAL. THE TVSS SHALL BE CONNECTED TO THE AC SYSTEM THROUGH A IMC INTERMEDIATE METALLIC CONDUIT o OTHERWISE SPECIFIED. CIRCUIT BREAKER IN THE AC PANELBOARD AND SHALL BE MOUNTED INTEGRAL WITH THE PANELBOARD OR _ UTS DIRECTLY ADJACENT. MGB MASTER GROUND BAR v +' 14. ALL POWER AND GROUNDING CONNECTIONS SHALL BE CRIMP STYLE, COMPRESSION WIRE LUGS AND WIREN MIN MINIMUM co BY THOMAS AND BETTS (OR EQUAL). LUGS AND WIRENUTS SHALL BE RATED FOR OPERATION AT NO LESS THAN 5. T1 TVSS DEVICES SHALL BE INSTALLED IN ALL NEW T1 INSTALLATIONS (TYPE AS APPROVED BY AT&T M) CL :3 75-C (90'C IF AVAILABLE). N.T.S. NOT TO SCALE Q o 6. THE SUBCONTRACTOR SHALL INSPECT THE EXISTING TELCO SYSTEM FOR TVSS PRESENCE AND REPORT c 4-0 15. RACEWAY AND CABLE TRAY SHALL BE LISTED OR LABELED FOR ELECTRICAL USE IN ACCORDANCE WITH FINDINGS TO CONTRACTOR. PVC RIGID (SCH.40) POLYVINYL ° �' NEMA, UL, ANSI/IEEE, AND NEC. CHLORIDE CONDUIT 7. SURGE SUPPRESSION AND PROTECTION DEVICES SHALL BE IN ACCORDANCE WITH THE REQUIREMENTS OF THE E 16. NEW RACEWAY OR CABLE TRAY WILL MATCH THE EXISTING INSTALLATION WHERE POSSIBLE. NATIONAL ELECTRICAL CODE (NEC) ARTICLE 250, 280, 285, AND CHAPTER 8, AS APPLICABLE. RBS RADIO BASE STATION o REF REFERENCE 'c: ° 17. ELECTRICAL METALLIC TUBING (EMT) OR RIGID NONMETALLIC CONDUIT (I.E., RIGID PVC SCHEDULE 40, OR - � DETAIL REQ REQUIRED -0 RIGID PVC SCHEDULE 80 FOR LOCATIONS SUBJECT TO PHYSICAL DAMAGE) SHALL BE USED FOR EXPOSED rll 7 � �'` INDOOR LOCATIONS. E03 RF RADIO FREQUENCY SCALE: N.T.S. RGS RIGID GALVANIZED STEEL o 18. ELECTRICAL METALLIC TUBING (EMT), ELECTRICAL NONMETALLIC TUBING (ENT), OR RIGID NONMETALLIC 0 �- CONDUIT (RIGID PVC, SCHEDULE 40) SHALL BE USED FOR CONCEALED INDOOR LOCATIONS. TRANSPORT T1 LINES RWY RACEWAY c0 -d SIAD SMART INTEGRATED ACCESS c Q 19. GALVANIZED STEEL INTERMEDIATE METALLIC CONDUIT (IMC) SHALL BE USED FOR OUTDOOR LOCATIONS 1 . ALL RACEWAY SHALL COMPLY WITH THE REQUIREMENTS OF THE NATIONAL ELECTRICAL CODE (NEC, NFPA DEVICE 0 ABOVE GRADE. o �; 70), CHAPTER 8. > TBD TO BE DETERMINED U 0 2. ALL SPECIFIED MATERIAL FOR EACH LOCATION (E.G., OUTDOORS, INDOORS-OCCUPIED, E -0 20. RIGID NONMETALLIC CONDUIT (I.E., RIGID PVC SCHEDULE 40 OR RIGID PVC SCHEDULE 80) SHALL BE USED 0 0 INDOORS-UNOCCUPIED, PLENUMS, RISER SHAFTS, ETC.) SHALL BE APPROVED, LISTED, OR LABELED AS TBR TO BE RESOLVED UNDERGROUND; DIRECT BURIED, IN AREAS OF OCCASIONAL LIGHT VEHICLE TRAFFIC OR ENCASED IN REINFORCED ,�, .� CONCRETE IN AREAS OF HEAVY VEHICLE TRAFFIC. REQUIRED BY THE NEC. TYP TYPICAL T 3. METALLIC CONDUIT OR TUBING FOR T1 LINES SHALL BE BONDED TO GROUND AT BOTH ENDS. VIF VERIFY IN FIELD 1-- 4. FOR NOKIA GSM BTS CABINET ONLY - THE T1 CABLE SHALL BE IDENTIFIED AT BOTH ENDS WITH A 1.6 21 . LIQUID-TIGHT FLEXIBLE METALLIC CONDUIT (LIQUID-TITE FLEX) SHALL BE USED INDOORS AND OUTDOORS, COMPUTER-PRINTED SELF-LAMINATING POLYESTER WIRE MARKERS (BRADY CORP. OR EQUAL). USE THE N ° WHERE VIBRATION OCCURS OR FLEXIBILITY IS NEEDED. "FROM" LOCATION FOLLOWING TYPICAL ID NAME AT THE NIU AND AT THE NOKIA BTS: cn o 22. CONDUIT AND TUBING FITTINGS SHALL BE THREADED OR COMPRESSION-TYPE AND APPROVED FOR THE 0 3. LOCATION USED. SETSCREW FITTINGS ARE NOT ACCEPTABLE. AT&T UMTS 1 ABBREVIATIONS & SYMBOLS o z LEC CCT# E03 SCALE: N.T.S. 0 0_ 0 0 T . w at&t BECHTEL ASSOCIATES SITE NAME: FISHERS ISLAND �4``G 090 m U) PROFESSIONAL CORPORATION • � � R: NYNYNY0801 +* _ � ELECTRICAL, TVSS NOTES, ABBREV. V SITE NUMBER: a o A UNIT OF BECHTEL CORPORATION SYMBOLS j U ORIENTAL AVENUE AND ETTRICK AVENUE 0 04/23/13 LTE-ISSUED FOR CONSTRUCTION ANA s6 RC & _�; 0, 3 5275 WESTVIEW DRIVE FISHERS ISLAND, NY 06390 No. DATE REVISIONS BY CHK WEI °4s43e�� ��'� JOB NUMBER DRAWING NUMBER EREV L_ m a 0 FREDERICK, MD 21703-8386 USA ARoFoN��SCALE: As NOTED DESIGNIED BY: MG DRAWN BY: MG - 25736-415 T3-NYNYNY0801 - E03 0 '�Q SIZE 22' x 34" ANSI D" _N . GROUNDING NOTES (AS APPLICABLE) 6 AWG STRANDED Cu m 1 . THE SUBCONTRACTOR SHALL REVIEW AND INSPECT THE EXISTING FACILITY GROUNDING SYSTEM AND LIGHTNING NEWTON INSTRUMENT COMPANY, INC. WIRE WITH GREEN, 600V, +, PROTECTION SYSTEM (AS DESIGNED AND INSTALLED) FOR STRICT COMPLIANCE WITH THE NEC (AS ADOPTED BY THWN INSULATION o THE AHJ), THE SITE—SPECIFIC (UL, LPI, OR NFPA) LIGHTING PROTECTION CODE, AND GENERAL COMPLIANCE BUTNER, N.C. OR APPROVED EQUAL (SUNLIGHT RESISTANT) OR BLACK MARKED Q WITH TELCORDIA AND TIA GROUNDING STANDARDS. THE SUBCONTRACTOR SHALL REPORT ANY VIOLATIONS OR NO. REQ. PART NO. DESCRIPTION ADVERSE FINDINGS TO THE CONTRACTOR FOR RESOLUTION. AS REQUIRED BY NEC 0 1 1/4"x4"x30" SOLID GND. BAR GROUND BAR ON 2. ALL GROUND ELECTRODE SYSTEMS (INCLUDING TELECOMMUNICATION, RADIO, LIGHTNING PROTECTION, AND AC 2 2 A-6056 WALL MTG. BRKT. WALL, FLOOR 0 POWER GES'S) SHALL BE BONDED TOGETHER, AT OR BELOW GRADE, BY TWO OR MORE COPPER BONDING 3 2 3061 -4 INSULATORS OR ON ANTENNA v CONDUCTORS IN ACCORDANCE WITH THE NEC. O TOWER m 0 ® 4 3012-1 5/8"-11x1 " H.H.C.S. 1 0 3. THE SUBCONTRACTOR SHALL PERFORM IEEE FALL—OF—POTENTIAL RESISTANCE TO EARTH TESTING (PER IEEE c U 1 100 AND 81 ) FOR NEW GROUND ELECTRODE SYSTEMS. THE SUBCONTRACTOR SHALL FURNISH AND INSTALL 05 4 3015-8 5/8 LOCKWASHER c 6 SUPPLEMENTAL GROUND ELECTRODES AS NEEDED TO ACHIEVE A TEST RESULT OF 5 OHMS OR LESS. TESTS OO OO 00 00 O O O SHALL BE PERFORMED IN ACCORDANCE WITH 24782-000-3PS—EG00-0001 , DESIGN & TESTING OF FACILITY v GROUNDING FOR CELL SITES. DOUBLE CRIMP O O 00 00 OQ 00 00 m CONNECTION 0 a 4. METAL RACEWAY SHALL NOT BE USED AS THE NEC REQUIRED EQUIPMENT GROUND CONDUCTOR. STRANDED v 3 COPPER CONDUCTORS WITH GREEN INSULATION, SIZED IN ACCORDANCE WITH THE NEC, SHALL BE FURNISHED INTERIOR 2 3 E AND INSTALLED WITH THE POWER CIRCUITS TO BTS EQUIPMENT. GROUND RING 0 EXOTHERMIC WELD-/ ANGLE SHOWN TO V) 5. EACH BTS CABINET FRAME SHALL BE DIRECTLY CONNECTED TO THE MASTER GROUND BAR WITH GREEN O 5 4 (WELDING ROHIBITED ILLUSTRATE WELD v Lo INSULATED SUPPLEMENTAL EQUIPMENT GROUND WIRES, 6 AWG STRANDED COPPER OR LARGER FOR INDOOR �� I 0 J AT THE LOWEST N BTS; 2 AWG STRANDED COPPER FOR OUTDOOR BTS. ON ROOFTOPS) ��� POINT ON THE BAR C ° A _° FOR ALL GROUNDING CONNECTIONS BELOW GRADE. P 13" 2 AWG SOLID BARE TINNED a� 6. EXOTHERMIC WELDS SHALL BE USED / 4„ COPPER GROUND CONDUCTOR. /, EXOTHERMIC EXOTHERMIC WELD TO BURIED 0 v 7 . APPROVED ANTIOXIDANT COATINGS (I.E., CONDUCTIVE GEL OR PASTE) SHALL BE USED ON ALL COMPRESSION 13" 1 WELD GROUND RING AND GROUND BAR 0 AND BOLTED GROUND CONNECTIONS. 0 v 8. ICE BRIDGE BONDING CONDUCTORS SHALL BE EXOTHERMICALLY BONDED OR BOLTED WITH STAINLESS STEEL L HARDWARE TO THE BRIDGE AND THE TOWER GROUND BAR. EACH GROUND CONDUCTOR TERMINATING ON ANY GROUND BAR SHALL HAVE INSTALLATION OF GROUND WIRE 0 9. ALUMINUM CONDUCTOR OR COPPER CLAD STEEL CONDUCTOR SHALL NOT BE USED FOR GROUNDING AN IDENTIFICATION TAG ATTACHED AT EACH END THAT WILL IDENTIFY ITS '11 ' 18 TO COAX CABLE GROUND BAR DETAIL 0 U) CONNECTIONS. ORIGIN AND DESTINATION. 0 :a E E04 SCALE: N.T.S. 10. MISCELLANEOUS ELECTRICAL AND NON-ELECTRICAL METAL BOXES, FRAMES AND SUPPORTS SHALL BE BONDED SECTION "P" - SURGE PROTECTORS N 0 TO THE GROUND RING, IN ACCORDANCE WITH THE NEC. =3 -° CABLE ENTRY PORTS (HATCH PLATES) (2 AWG) TO TOWER MOUNTED TO TRANSMIT 11 . METAL CONDUIT AND TRAY SHALL BE GROUNDED AND MADE ELECTRICALLY CONTINUOUS WITH LISTED BONDING GENERATOR FRAMEWORK (IF AVAILABLE) (2 AWG) AMPLIFIER UNITS ANTENNA FITTINGS OR BY BONDING ACROSS THE DISCONTINUITY WITH 6 AWG COPPER WIRE UL APPROVED GROUNDING TELCO GROUND BAR (2 AWG) (TMA) (WHEN •� REQUIRED) AND TYPE CONDUIT CLAMPS. COMMERCIAL POWER COMMON NEUTRAL GROUND BOND (2 AWG)) RECEIVE ANTENNA 0 12. GROUND CONDUCTORS USED IN THE FACILITY GROUND AND LIGHTNING PROTECTION SYSTEMS SHALL NOT BE +24V POWER SUPPLY RETURN BAR (2 AWG) ROUTED THROUGH METALLIC OBJECTS THAT FORM A RING AROUND THE CONDUCTOR, SUCH AS METALLIC -48V POWER SUPPLY RETURN BAR (2 AWG) TX v 0 CONDUITS, METAL SUPPORT CLIPS OR SLEEVES THROUGH WALLS OR FLOORS. WHEN IT IS REQUIRED TO BE RECTIFIER FRAMES. WEATHERPROOFING HOUSED IN CONDUIT TO MEET CODE REQUIREMENTS OR LOCAL CONDITIONS, NON-METALLIC MATERIAL SUCH AS COAX SUPPRESSION / KIT (TYP.) a _0 PVC PLASTIC CONDUIT SHALL BE USED. WHERE USE OF METAL CONDUIT IS UNAVOIDABLE (E.G., NON-METALLIC RX1/RX2 RX1/RX2 v CONDUIT PROHIBITED BY LOCAL CODE) THE GROUND CONDUCTOR SHALL BE BONDED TO EACH END OF THE SECTION "A" - SURGE ABSORBERS E METAL CONDUIT. m 0 INTERIOR GROUND RING (2 AWG) I I x—ANTENINA CABLE ° -� 13. ALL TOWER GROUNDING SYSTEMS SHALL COMPLY WITH THE REQUIREMENTS OF ANSI/TIA 222. FOR TOWERS EXTERNAL EARTH GROUND FIELD (BURIED GROUND RING) (2 AWG) = KIT (TYP.) BEING BUILT TO REV G OF THE STANDARD, THE WIRE SIZE OF THE BURIED GROUND RING AND CONNECTIONS METALLIC COLD WATER PIPE (IF AVAILABLE) (2 AWG) JUMPER CABLES-/ / STANDARD GROUND BETWEEN THE TOWER AND THE BURIED GROUND RING SHALL BE CHANGED FROM 2 AWG TO 2/0 AWG. IN BUILDING STEEL (IF AVAILABLE) (2 AWG) I I I I KIT (TYP.) •�' U) ADDITION, THE MINIMUM LENGTH OF THE GROUND RODS SHALL BE INCREASED FROM 8 FEET TO 10 FEET. CL SECTION "I" - ISOLATED GROUND ZONE (SEE NOTE) o 0 a ALL COMMUNICATIONS EQUIPMENT FRAMES. .0 rn ISOLATED GROUND BAR - IGB (2 AWG) CONNECTOR—/ WEATHERPROOFING o DETAIL NOTES: KIT (TYP.) 4- Cco v _c 1 . EXOTHERMICALLY WELD 2 AWG BARE TINNED SOLID COPPER CONDUCTOR #6 AWG STRANDED Cu .� GROUND BAR. ROUTE CONDUCTOR TO BURIED GROUND RING AND PROVIDE FROM TMA WIRE WITH GREEN, PARALLEL EXOTHERMIC WELD. (WHEN REQUIRED) / 60OV, THWN INSULATION -v o 2. USE PERMANENT MARKER TO DRAW THE LINES BETWEEN EACH (SUNLIGHT RESISTANT) SECTION AND LABEL EACH SECTION ("P", "A", "I") WITH 1 " HIGH LETTERS. /� CIGBE (GROUND BAR), REFER TO DETAIL co a NOTE: 118/E05 TO NEAR/ o SEEONOTET2NNA 1 . DO NOT INSTALL CABLE GROUND 0 KIT AT A BEND AND ALWAYS DIRECT E v GROUND WIRE DOWN TO CIGBE (RGB) REFERENCE GROUND BAR — DETAIL 2. EXISTING CIGBE MAY BE USED IN WI AWG Cu STRANDED WIRE WITH GREEN, cn CONVENIENTLY LOCATED. 600V, THWN INSULATION I- (SUNLIGHT RESISTANT) c BONDED TO STRUCTURE n 1 19 MASTER/EQUIPMENT GROUND BAR DETAIL GROUND BOTTOM CONNECTION OF GROUND BAR. 1 13 DETAIL Eo4 SCALE: N.T.S. ri22 GROUND WIRE TO GROUND BAR 0 z �O4SCALE: N.T.S. E04 SCALE: N.T.S. a 0 0 75 1 co at&t BECHTEL ASSOCIATES SITE NAME: FISHERS ISLAND m a N PROFESSIONAL CORPORATION 4 0 1 ,* s � GROUNDING NOTES & DETAILS I lie c 4) SITE NUMBER. NYNYNY080 at&t o a) A UNIT OF BECHTEL CORPORATION 4 , ORIENTAL AVENUE AND ETTRICK AVENUE 0 04/23/13 LTE-ISSUED FOR CONSTRUCTION ANA s6 RC c� w 5275 WESTVIEW DRIVE �w 3 t FISHERS ISLAND, NY 06390 N0. DATE REVISIONS BY CHK PPSFpA� 5439' �?�' JOB NUMBER DRAWING NUMBER REV FREDERICK, MD 21703-8386 USA a 0 �` °F�ss+°N� 25736-415 T3-NYNYNY0801 -E04 0 SCALE: AS NOTED DESIGNED BY: MG DRAWN BY: MG 0 aQ SIZE 22" x 34 ANSI "C)'!