Loading...
HomeMy WebLinkAbout38643-Z yyFF9I f Town of Southold Annex 4/3/2014 P.O. Box 1179 54375 Main Road 'ffi! Southold, New York 11971 f CERTIFICATE OF OCCUPANCY No: 36844 Date: 4/3/2014 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 8960 Great Peconic Bay Blvd, Laurel, SCTM 473889 Sec/Block/Lot: 126.-5-6 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this officed dated 1/15/2014 pursuant to which Building Permit No. 38643 dated 1/27/2014 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: roof mounted solar panels on an existing one family dwelling as applied for. The certificate is issued to D'addario, James & D'addario, Janet (OWNER) of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 38643 3/20/14 PLUMBERS CERTIFICATION DATED Authorized Signature TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE $9 SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit 38643 Date: 1/27/2014 Permission is hereby granted to: D'addario, James & Daddario, Janet _ 45 Clock Tower Ln Old Westbury, NY 11568 To: Installation of solar panels as applied for. At premises located at: 8960 Great Peconic Bay Blvd, Laurel SCTM # 473889 Sec/Block/Lot # 126.-5-6 Pursuant to application dated 1/15/201 and apn~' ild ing Inspector. To expire on 7129/2015. Fees: ANELS $50.00 CO - ADDITIONS TO ACCESSORY BUILDINGS $50.00 Total: $100.00 Building Inspector Form No. 6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings, property lines, streets, and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal (S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of I% lead. 5. Commercial building, industrial building, multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings (prior to April 9, 1957) non-conforming uses, or buildings and "pre-existing" land uses: 1. Accurate survey of property showing all property lines, streets, building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied, the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy - New dwelling $50.00, Additions to dwelling $50.00, Alterations to dwelling $50.00, Swimming pool $50.00, Accessory building $50.00, Additions to accessory building $50.00, Businesses $50.00. 2. Certificate of Occupancy on Pre-existing Building - $100.00 3. Copy of Certificate of Occupancy - $.25 4. Updated Certificate of Occupancy - $50.00 5. Temporary Certificate of Occupancy - Residential $15.00, Commercial $15.00 Date. 111 311 y New Construction: Old or Pre-existing Building: x (check one) Location of Property: 8960 Great Peconic Bay Blvd Laurel House No. Street Hamlet Owner or Owners of Property: James D'Addario Suffolk County Tax Map No 1000, Section 126 Block 5 Lot 6 Subdivision Filed Map. Lot: Permit No. Date of Permit. Applicant: GreenLo9ic LLC Health Dept. Approval: Underwriters Approval: Planning Board Approval: Request for: Temporary Certificate Final Certificate: x (check one) Fee Submitted: $ 50.00 76knt Signature rjf S 0 Town Hall Annex Telephone (631) 765-1802 54375 Main Road Fax (631) 765-9502 P.O. Box 1179 0~ 45k rog Southold, NY 11971-0959 - e r. riche rt(o)town. so uthold. ny. us Z2 coumN BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION Issued To: D'Adclano Address: 8960 Peconic Bay Blvd City: Laurel St: NY Zip: 11948 Building Permit* 38643 Section: 126 Block: 5 Lot: 6 1 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE lContractor: DBA: Green Logic LLC License No: 43858-me SITE DETAILS Office Use Only Residential Indoor Basement Service Only Commerical Outdoor 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey n Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures HID Fixtures Service 3 ph Hot Water GFCI Recipt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Fluorescent Fixture Pumps Transformer Appliances Dryer Recpt Emergency Fixtures Time Clocks Disconnect Switches Twist Lock Exit Fixtures TVSS Other Equipment: roof mounted PHOTOVOLTAIC SYSTEM to include, 34 Sun Power SPRA20-250 modules, 1 -Sun Power SPR6000 & 1 -Sun Power SPR3000 inverters. (8,50OWatts) Notes: Inspector Signature: Date: March 20 2014 81-Cert Electrical Compliance Form.xis ~f ~O~~,OF SOUry„ TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLEIG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING / STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION ( ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) REMARKS: DATE INSPECTOR r Pacifico Engineering PC Engineering Consulting 700 Lakeland Ave, Suite 2B Ph: 631-988-0000 Bohemia, NY 11716 Fax: 631-382-8236 P www.pacificoengineering.com ~N Gc solar@pacificoengineering.com March 11, 2014 Town of Southold Building Department 54375 Route 25, P.O. Box 1179 Southold, NY 11971 Subject: Solar Energy Installation for James D'Addario Section: 126 8960 Peconic Bay Blvd Block: 5 Laurel, NY 11948 Lot: 6 1 have reviewed the solar energy system installation at the subject address. The units have been installed in accordance with the manufacturer's installation instructions and the approved construction drawing. I have determined that the installation meets the requirements of the 2010 NYS Building Code, and ASCE7-05. To my best belief and knowledge, the work in this document is accurate, conforms with the governing codes applicable at the time of submission, conforms with reasonable standards of practice, with the view to the safeguarding of life, health, property and public welfare. Regards, Ralph Pacifico, PE Professional Engineer r b ZsFO oea~ez ~~e AgOFESS'tO~P Ralph Pacifico, ro essional Engineer NY 066182 / NJ 24GE04744306 FIELD ON REPORT DATE COMMENTS ~~ro a FOUNDATION (1ST) -C a FOUNDATION (ZND) ck,o y Cj ROUGH FRAMING & y PLUMING E r INSULATION PER N. Y. H STATE ENERGY CODE T c • r FINAL AD ITIONAL COMMENTS 31 Fe. do Lj ~tz TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following, before applying? TOWN HALL Board of Health SOUTHOLD, NY 11971 4 sets of Building Plans TEL: (631) 765-1802 Planning Board approval FAX: (631) 765-9502 Prr ffc~~ Survey SoutholdTown.NorthFork.net PERMIT NO.E- Check Septic Form N.Y.S.D.E.C. Trustees Flood Permit Examined 1 7 2011 I r Storm-Water Assessment Form JA N 15 2014 contact: Approved I 1 t / 120 (u Mail to: GreenLogic LLC Disapproved a/c 425 County Road 39A, Southampton, NY 11968 Phone: 631-771-5152 Expiration 7 19 , 20 1 But ding APPLICATION FOR BUILDING PERMIT 3 INSTRUCTIONS Date 20ff- a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans, accurate plot plan to scale. Fee according to schedule. b. Plot plan showing location of lot and of buildings on premises, relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application, the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e. No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim, the Building Inspector may authorize, in writing, the extension of the permit for an addition six months. Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County, New York, and other applicable Laws, Ordinances or Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances, building code, housing code, and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. GreenLogic LLC (Signature of applicant or name, if a corporation) 425 County Road 39A, Southampton, NY 11968 (Mailing address of applicant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder Contractor Name of owner of premises James D'Addario (As on the tax roll or latest deed) If applicant is corporation, signature of duly authorized officer (Name and t e of corporate ) Builders License No. 40227-H Plumbers License No. Electricians License No. 43858-ME Other Trade's License No. 1. Location of land on which proposed work will be done: 8960 Great Peconic Bay Blvd Laurel House Number Street Hamlet County Tax Map No. 1000 Section 126 Block 5 Lot 6 Subdivision ` .Filed.Map No. Lot 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy Single family dwelling b. Intended use and occupancy Single family dwelling 3. Nature of work (check which applicable): New Building Addition Alteration Repair Removal Demolition Other Work Roof mounted solar electric system (Description) 4. Estimated Cost $33,724.00 Fee (To be paid on filing this application) 5. If dwelling, number of dwelling units Number of dwelling units on each floor If garage, number of cars 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of existing structures, if any: Front Rear Depth Height Number of Stories Dimensions of same structure with alterations or additions: Front Rear Depth Height Number of Stories 8. Dimensions of entire new construction: Front Rear Depth Height Number of Stories 9. Size of lot: Front Rear Depth 10. Date of Purchase Name of Former Owner 11. Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law, ordinance or regulation? YES NO X 13. Will lot be re-graded? YES_ NO X Will excess fill be removed from premises? YES_ NO_ 8960 Great Peconic Bay Blvd 14. Names of Owner of premises James D'Addario Address Laurel, NY Phone No. Name of Architect yarifirn FnyinaPrina P C Address700 Lakeland Ave. Bohemia, N1Phone No 631-gRR-nnn0 Name of Contractor GreenLogic LLC Address 42S Cmmty Rnad 351A Phone No. 631-771-5152 Southampton, NY 11968 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO * IF YES, SOUTHOLD TOWN TRUSTEES & D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey, to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. 18. Are there any covenants and restrictions with respect to this property? * YES NO * IF YES, PROVIDE A COPY. STATE OF NEW YORK) SS: COUNTY OF Suffolk ) Nesim Albukrek being duly swom, deposes and says that (s)he is the applicant (Name of individual signing contract) above named, (S)He is the Contractor (Contractor, Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be performed in the manner set forth in the application fil ~0. Hp Swo` m to before me thi o o ex, 2% 90 h~dayof (Q 20~ o oo%ap Y 1 CMMI AVBLIC 0 tAAIA~ Notary Public `oG do Rog Signature of Applicant yry'STATE J ~ 'A-AAA' Scott A. Russell WO James A. Richter, R.A. SUPERVISOR Michael M. Collins, P.E. too SOU11iOID TOWN HAIL- P. 0.13 ~ 1179 ~j $3095 M R"A-SOMMLD. NEW YORK 11 Telephone I: (631) - 765 -1560c 7 MICHARGC0I.U Wr0 M.SOU1730IDNY.US J Office of the Engineer JAN 17 2014 D Town of Southold STORMWATER MANAGEMENT CONTROL PLAN LHET (TO BE COMPLETED BY THE APPLICANT) TO: ENGINEERING DEPARTMENT AMSBATTALA71B ATIAIM LVa&Mls or RW;VIPIHTIAV.• FROM BUILDING DEPARTMENT ? COPY of completed Application for Building Permit DATE: ? Storrnwater Management Control Plan APPLICANT.: GreenLogic LLC ? Completed Chapter 236 Stormwater S.C.T.M. 1000-126-5-6 Review Checldist PROPERTY ADDRES& 8960 Peconic Bay Blvd, Laurel, NY 11948 BRIEF PROJECT DESCRIPTION: Roof mounted solar electric system D~FI 1~(Ct ltd (!t' ~t2 I ]WO FOR EN MG DEPARTMENT USE ONLY RevieweLI Date ~ ` 1 7 -ti i ® . ? Inrormation Required: DATE: CHAPTER 236 APPLIC"T. LLC Storm'water Review Checklist S.C.T.M.#; 1000.126-5 • 1000-126-5-6 6 Stormwater Management Control Plan Requirements' Yes No PHYSICAL ADDRESS: 8960 Peconic Bay Blvd, Laurel, NY NA I • Plan drawn to scale of not leasthan b0 feet to the inch showing: If No or NA, Please Provide Additional Information a. location and d Ofproperty.boundwiss x b. total site acreage c. existing and natural and man-made fanfares on and within 500 feet of the site bout m . bed is 2365.17 2 d. test hole data indicating soil x and the to water e. Proposed limits of clewing end theme total o}od~d disturbance f. existing and proposed coatouis ofthe site x g. location of all existing and (mmnnum 2, interval) x sidewalks pioposad stmctures, utilities roads, driveways, and h. spot IP'ade and finished floor elavations for structures existing end Proposed i, location of the swimming pool discharge ring j. location of Proposed soil stockpile area(sy k, location of the Proposed O2nahuction Mtn n staging areas x x I. location of the Proposed,concrM washout sib m. location of all Proposed erosion and sediment control measures x 2. Plan includes caleulationa showing that the storm water x are sized to capture, store and h4lbute improvements on-site NIIO 'all im ervious surfaces e a two-inch rainfall 3. Detail drawings (pyy x a. erosion and c provided for. sediment comrola b, contraction enUancc x x c. inlet structures (a•& catefi basins dmios, etc.) d. leaching strttotures (e.g. on besh ins, swa(esetc REVISED 7/24/2013 ,~0 6 Town Hall Annex #f +j)!r Telephone (631) 7651804 54375 Main Road (631) 7 5 Mio P.O.Box1179 roger.richert t""tewnIS)E nVus Southold, NY 11971-0959 "~UIII1, BUILDING DEPARTMENT TOWN OF SOUTHOLD APPLICATION FOR ELECTRICAL INSPECTION i REQUESTED BY. Tamara Romero Date: Company Name: creenLogic LLC Name: Robert Skypala License No.: 43858-ME Address: 425 County Road 39A Southampton, NY 11968 Phone NO.:. 631-771-5152 JOBSITE INFORMATION: (*Indicates required information) *Name: James D'Addario *Address: R9Rn Paronir Ray Rlyd a r I NY *Cross Street: Ray Aye *Phone No.: 631-335-R197 . Permit No.: Tax Map District: 1000 Section: 126 Block: 5 Lot: 6 *BRIEF DESCRIPTION OF WORK (Please Print Clearty) Roof mounted solar electric system 34 SunPower SPR-X20-250 modules 8,500 Watts 1 SunPower SPR6000p & 1 SunPower SPR3000p (Please Circle All That Apply) *Is job ready for inspection: YES NO Rough In Final *Do you need a Temp Certificate: _ YES NO Temp Information (if needed) *Service Size: 1 Phase 3Phase 100 150 200 300 350 400 Other *New Service: Re-connect Underground Number of Meters Change of Service Overhead Additional Information: PAYMENT DUE WITH APPLICATION 82-RequestforInspection Form Gt GREENLOGICO ENERGY January 10, 2014 Town of Southold Building Department Town Hall 53095 Route 25 Southold, NY 11971 Dear Building Inspector: Please find attached a building permit application on behalf of James D'Addario who has engaged us to install a roof-mounted solar photovoltaic (PV) electric system at his home at 8960 Great Peconic Bay Blvd, Laurel, NY 11948. In connection with this application, please find attached: • Building Permit application • A Storm Water Assessment Run-off Form • Certificate of Occupancy Application • 2 Surveys of the Premises • 4 Engineer's Reports (2 originals and 2 copies) • 2 One Line Electrical Schematics r)r • 2 Spec. sheets of the solar panels (SunPower SPAQ) • 2 Spec. sheets of the inverter (SunPower SPR6000p & SPR3000p) • 2 Code Compliant Manuals for Racking System • GreenLogic Suffolk County Home Improvement License • GreenLogic Certificate of Liability Insurance • GreenLogic Certificate of Worker's Compensation Insurance Coverage • Installation Manager's Master Electrician's License • Check for $100 ($50 Building Permit/$50 CO) • Application for Electrical Inspection with a check for $100 Please let us know if you need anything else in connection with this application. Yours truly, Tamara Romero Account Manager GreenLogic LLC 631-771-5152 ext. 120 GREEN LOG IC, LLC • www_GreenLogic-coin Tel: 877.771.4330 Fax: 877.771.4320 SOUTHAMPTON ROSLYN HEIGHTS 425 County Rd. 39A 200 S. Service Rd., #108 Southampton, NY 11968 Rosyln Heights, NY 11577 G ~?GREENLOGIC" ENERGY March 27, 2014 F The Town of Southold J,"I Building Department U 2D14 54375 Route 25 P.O. Box 1179 Southold, NY 11971 Re: Building Permit No. 38643 James D'Addario 8960 Peconic Bay Blvd, Laurel, NY To the Building Inspector: Enclosed please find the Engineer's Certification Letter for James D'Addario's solar electric system, which we installed at the above reference address. Please arrange to send him the Certificate of Occupancy and close out the building permit. Please let me know if you have any questions about the installation. Sincerely, Tamara Romero Account Manager GreenLogic LLC 631-771-5152 Ext. 120 GREENLOGIC. LLC • www.GreenLogic.com Tel: 877.771.4330 Fax: 877.771.4320 SOUTHAMPTON ROSLYN HEIGHTS 425 County Rd. 39A 200 S- Service Rd., 4108 Southampton. NY 11968 Rosyln Heights , NY 11577 r 2 PROPOSED NEW SEPTIC SYSTEM 1 - 1000 qaL PRECAST SEPTIC TAW 1 - 101 • S 'DEEP LEACMNG POOL WITH 3' SAND (SN COLLAR 3' ABOVE GROUND WATER h - - @ RR MOWED AhTIC REPSYSTEM LACED IN PLACE C G awl y 'U + 0" 14 II P ! - Z It Y: L `O" u OT • u r SURVEY OF v2 s z LOT 6 ( FLORENCE G. DOWNS) 0~J t _ co MAP OF PROPERTY OF A. L. DOWNS " J' I 3 FILED AU6. 14,NR2* AS'MAPNO. 21 AT LAUREL ~ 14f1EA 20,012 y4ff, to No ikle : . 'M . . TOWN OF SOUTHOLD z SUFFOLK COUNTY, M.Y. `t .1000-424- 05-06 oF~eriy SCALE:1°=40' 6~4te S MET C ;t SENT 29,1986 Bois' Fy Dec. 29, 1993 floundamw * AVA 16,1999 f Tie Dk/arcel CERTWIND Al To: •tq,1i~MU00 _ 7M #E MIIIt70G16if frMTfR, INC. MARYaF/ JA1yt~,Eyy~~,, tOOi ~ CM#C"O 77TLE IiWWRANCE COMPANY e *8 WANT" a 1°" PEMiVS ,&STRACT, INC. N.Y,S LIG NO. 4908 - - Oo\, fL3/) 765 - SOLO FX~83V1 765- /797 - G P~ \ . a am 909 230. TRAVELER STREET At Y. 0971 1 Pacifico Engineering PC _ Engineering Consulting 700 Lakeland Ave, Suite 2B Ph: 631-988-0000 Bohemia, NY 11716 - P Fax: 631-382-8236 .~~a solar@pacificoengineering.com www.pacifccengineering.comP!41 January 7, 2014 Town of Southold , w Building Department VED AS NOTED c 1r t1-~ APR 54375 Route 25, P.O. Box 1179 /y (r3~ Southold, NY 11971 r DATE: 2 B.P. Subject: Solar Energy Installation for FEE James D'Addario Section: ItNT :y s'.-- 8960 Peconic Bay Blvd Block: 57a-, 2 ,ti Laurel, NY 11948 Lot: 8rN COVI'L`( VaI ; H ALL CODES OF NEW YORK STA; ~ L-: & TOWN CODES FGr; rvU AS REQUIRED AN' not InITION OF 2. ROUGH FRAIMiNu & PLUi~1BING 3. INSULATION cnl r rl n m 4. FINAL - CONSTRUCTION MUST -ET THE I have reviewed-tWrobfi ucture at ilia subject address. The structure G9M0p6fl tQCtWWhI all { ht~ OHS. the roof mounted system. The units are to be installed in accordance with the manufacturer's installation instructions. I have determined that the installation will meet the requirements of the 2010 NYS Building Code, and ASCE7-05 when installed in accordance with the manufacturer's instructions. Roof Section A B C Mean roof height 19 ft 13 ft 19 ft Pitch 4114 in/12 7 1/21n/12 51/2 in/12 Roof rafter 2x6 2x6 2x6 Rafter spacing 24 inch on center 24 inch on center 24 inch on center Reflected roof rafter span 7.1 ft 10.4 ft 5.8 ft RETAIN STORM WATER RUNOFF Table R802.5.1(1)allowablemax 10.8 ft 10.8 It 10.8 ft PURSUANT TO CHAPTER 236 The climactic and load information is below: OF THE TOWN CODE. CLIMACTIC AND Wind Live load, GEOGRAPHIC DESIGN Category Snow Load, sec gust, ASCE 7, pullout , to Fastener type CRITERIA Pg mph pat load, to Roof Section A C 20 120 61 1249 (2) #14-13 x4.5" DP1 Concealer Screws B 33 676 (2) #14-13 x4.5" DPI Concealer Screws C 61 639 (2) #14-13 x4.5" OPi Concealer Screws Weight Distribution Q,~{r array dead load 3.5 p load per attachment 440.00 p USE IS UNLAWFUL Ralph Pa PE WITHOUT CERTIFICA Professional l Engineer d' OF OCCUPANCY ph W 066182 E04744306 I ?GREENLOGIC ENERGY GreerlLogto. LLC Approved Jim D'Addarlo 8960 Peconic Bay Bhd Laurel NY, 11948 Surface i1: Total System Size: B.SkW i May Size: 3.5kW 2 stings of 7 and f string of 10 on SPR- 6000p (shared with surface 2) x Azimuth: 204' Pitch: 20* Monitoring Sysb SunPOwer eer 111 Panel/Array 9peN0eatlons: Panel: SunPower 250w Blade Reciting: Uniftac SunFrame Panel: 61.39" X 31.42" Array: 157.1"X 188.67' Surface: 195.5"X 216" \ \ Maglc1i: 62.14' Legend: V \i ® SuMover 250VV Panel - UniRac SunFrame Rail • 18 Eco-Fasten Duickfoot 2x8" True Douglas F6 Rafter 24' D.C. Notes: Number of Roof Layers: 1 Height above Roof Surface: 4" Materials Used: Eco-Fasten, UniRac, Sunpower. Fmnius Added Roof Wad of PV System: 3.5psf__ A En SaaY OP NEWS . Cal ~ w :'i~ ys o ~O aQ81 pq~FESS\~N~~ Drawn By: DRV Drawing # 1 of 11 Date: 1014113 REV: A Drawing Scale: 1/4"= 1.0' CtGREENLOGIC®j ENERGY Greentogk, LLC Approved Jim D'Addario 8960 Peconic Bay Blvd Laurel NY, 11948 \ Surface #1: Total System Size: 8.5kW O May Size: 3.5kW 2 strings of 7 and 1 slrkg of 10 on SPR- 6000p (shared with surface 2) Azimuth: 204° Pilch: 20°` \ Monitoring System: i SunPower ParrWArray SpecBicatlona: - i Panel: Sur Power 250w Black Racking: UniRac SunFrame Panel: 61.39"X 31.42" Array: 157.1"X 188.67" y Surface: 195.5" X 216" Magic 82.14' l.egend• I \ SunPower 250W Panel UNRac SunFrame Rail • 18 Eco-FaMen Ouickfoot f' \ 2x8 True Douglas Far Railer 24" O.C. Notes: j [A ~Vrj Number of Roof Layers:1 Height above Roof Surface: 4" Materials Used: Eco-Fasten, UniRac, Sunpower, Froriua Added Roof bad of PV ~ System: 3.5psf \ EnglneedArchitect Seal: ~pF NEyr y x Z~ .off' O ~ AAA veste'd' Drawn 4 DRV Drawing #20f 1 Dale: 10/0/4/13 REV: A Drawing Scale: 1/4" = 1.0' ~i ?GREENLOGICeI ENERGY GrwswLogl, LLC Appoved Jim D'Addario 8960 Peconic Bay Blvd Laurel NY, 11948 _ Surfsca t1: Total System Size: 8.5kW Ci 0 Array Size: 3.5kW 2 strings of 7 and 1 a" of 10 on SPR- _ 60DDP (shared with surface 2) Pitch: i Pdch: 20° ~ 2 rT\/ Azimuth: Monitoring System: SunPower PanDUArmy Specifications: Panel: SMPOeer 25Uw Blade Racking: Un[Rac SunFrame Panel 61.39' X 31.42" Array: 157X X X 188.67' Surface: 195.5"X216' Magic a: 62.14', Legend:-- ; L - ® SunPower 250W Panel 1 2 - UniRac SunFrame Rai • 18 Ecofasten Oniekfool a 2x8" True Douglas Fir Railer 24" o O.C. Notes: Number of Root Layers: 1 Height above Roof Surface: 4" Materials Used: Eco-Fasten, UniRac, Sunpower, Fronius / Added Roof bad of PV System: 3.5psf EuplnearfArchhacl SW: pp NE6{r 1 ,`P~~N PO9~ rijvey 77 I / FO ~8818'Z ~fi AR~FESs1 Drawn By: DRV Drawing 0 3 of 11 Date: 1014113 REV: A Drawing Style: 1/4"= 1.0' C GREENLOGICa ENERGY GTaanLoylc, LLC Approved Jim D'Addado 8960 Peconic Bay Blvd - Laurel NY, 11948 Surlaca R2: Total Syarem Sim: e5kW _..-l May Size: 3.75kW 1 string of 10 oa SPR6000p(Nramd with surface i ) 1string of 5 m SPR3000p(shared with sudace 3) - . • Azimuth: 204° _ Pitch: 32* Mangodng System: \ SunPower X I PanellArray yitclBcations: Panel: Sunl` w 250w Blade Racking: UniRac SunFrame Panel: 61.39" X 31.42" Array: 220.84" X 188.52" Surface: 261' X 234' I -------J Magic*: PORTSCAPE Legend: 1441 SunPower 250W Panel - - UniRac SunFrame Rail i I • 21 ECO•Fasten Quickfoot 6 9 2x8" True Douglas Fir Rafter 24" O.C. Notes: Number of Roof Layers: 1 \ Height above Roof Surface: 4" i \ Materials Used Eco-Fasten, UniRac. \ i \ Sunpower, PowerOne Added Roof load of PV System: 3.5psf i \ Engln Seal: i OF NE{yY t r n ~~OA o819% 9~FESSION* Drawn BY DRV Drawing i4 of 11 Date: 10/4/13 REV: A Drawing Scale: 1/4"Scale: 1/4" = 1.0' C GREENLOGICe ENERGY GreenLo9k, LLC Approved - I Jim D'Addario 8900 Pec0niC Bay BNd Lawel NY, 11948 . Surface X2: Total System Sae: 9.SkW ray Sae3.75kW Ar 1 sMng of 10 on SPRa000p(shomd wah surface 1 string of 5 on SPR3000p(shared with surface 3) i Azimuth: 204° Pitch: 3Y MoNtpkg System: SunPower Pan WArray9peci0cafcets:_ Panel: SunPower 25Dw Bieck - Racking: UniRac SunFrame Panel: 81.39" X 31.42' Tv / / Array: 220.84" X 188.52' i Surface: 281" X 234' I Magicd: PORTSCAPE Legend: _ _ ~}}J SwlPower 25OW Panel i / - UNRac SunFrame Rail % \ - • 21 Eco-Fasten Quickfoot B 2x8" Tme Douglas Fir Rafter 24" O.C. Notes: Number of Roof Layers: 1 Height above Roof Surface: 4" I Materials Used: Eco-Fasten, UnlRac, Sunpower, PowerOne Added Roof bad of PV System: 3.5psf Engineer/Architect Seal: F NE{yY 1P O BOA 888182 Q~ 9~FESSI Drawn By: DRV_ I Drawing 0 5 of 11 - Date: 1014113 REV: A Drawing Scale: V4" - 1.0' CfGREENLOGICO ENERGY _GrawaLogic, LLC Approved Jim D'Addedo 8960 Peconle Bay Blvd Laurel NY. 11948 Surface _i_2: _ _ _i TOM System Sim: 8.5kW l Array Size: 3.75kW 1 shing of 10 on SPR6000p(shamd with sudam 1) 4 - 1 string on 3000IX with surface Azimuth: 204' Pitch: onitoring System: - - / M , SunPower PamilArray t pacification: I Panel: SunPower 250w Black L' Racking: tlniRac SunFrame 3 4 Y Panel: 61.39'X 31.42' Array: 220,W X 188.52" . / Surface: 261"X 234' r Magic#: PORTSCAPE Legend: SunPo POwer 250W Panel UniRaC SunFrame Rail • 21 Eco-Fasten Ouickfoot 3 B B 2x6' True Douglas Fir Rafter 24' O.C. Notes: \ Number of Roof Layers: 1 Height above Roof Surface: 4" Materials Used: Eco-Fasten. UniRac, Sunpower, PowerOne Added Roof load of PV System: 3.5psf \ __EriginwrlArchiuet Seal: I 73 OF NE6y PAO/F I 'O ,j Is $ Z 2 FO Is 4.~ s O A9~FES Drawn By: DRV ng # 6 of 11 Date: 1014/13 REV: A Drawing Scale: 1/4" =1.0' ~i ?GREENLOGICe1 ENERGY GreenLogrc, LCC Approved Jim D'Addado 8980 Peconic Bay Blvd Laurel NY, 11948 Surface 0: Total System Size: 8.5kW Army Size: 1.25kW 1 string of 5 and 1 string of 5 on SPR- 3000p(shamd with Surface 2) Azirmth: 122° Pilch: 25° Monitadng System: - SwPower PanallArray Specifications: _ Panel: SunPower 250w Black Racking: UniRac SunFrame Panel: 51.39' X 31.42' Array: 184.17'X 98.78' Surface: X 113' Magic a_ 32.1 7" _ Legend: - SunPower Aim-0am _ - UniRac SunFrame Rail • 15 EcoFasten Ouickfoot / 2x8° True Douglas Fir Rater 24' O.C. Notes: Number of Roof Layers: 1 Height above Roof Surface: 4" Materials Used: Eco-Fasten, UniRac, Sunpower, PowerOne Added Roof load of PV System 3.5psf EnglovedArchitecl Seal: of NEy,r y ae. r- w Z ~ ~~FESSI Drawn By: DRV Drawing • 7 of 11 Date: 1,0/ : REV: A DrawinScale: 3f8'.=„ 1.0' _ I C GREENLOGICo ENERGY . GmwLogk, LLC Approved Jkn D'Addario 8960 Peconic Bay Blvd Laurel NY, 11948 Surface 03: Total System Size: 8.5kW Array Sae: 125kW 1 string of 5 and 1 string of 5 on SPR- 3000p(shered with Surface 2) Azimuth: 122° Pitch: 25° 2 ~ Monitoring System: j SunPower ! Pano rrlaUona: Panel: SunPower 2 250w 0w Blakack Racking: UrdRac SwFrame Panel: 61.39' X 31.42' Array: 184.17° X 98.76" / Surface: 255" X 113' Magic 32.17" _Legsnd: E14] SunPOwer 25001Panel Unitac SunFrarne Red • 15 Eco-Fasten Oulckfoot / g 8 2x6" Two Douglas Fir Rafter 24" Y O.C. Notes: Number of Roof Layers: 1 Height above Roof Surface: 4" Materials Used: FCo-Fasten, UNRac, Sunpower, PowerOne Added Roof load of PV System: 3.5psf Englneed Itect Seat OF Ne ,r,P N PA~~ p C i • 2 `~°,o es~s2~ o 9~FfSS10~~P~ _ Drawn By: DRV Drawing • 8 0111 Date: 1014113 REV: A Drawing Scale: 318"= LO' IctGREENLOGIC~ ENERGY GneenLoglc, LLC Approved Jim D'Addario 8960 Peconic Bay Blvd Laurel NY, 11948 Srface 03; Total System Size: 8.5kW - Array Size: 1.25kW 1 string of 5 and 1 String of 5 on SPR- 3000p(shered with Surface 2) Azimuth: 122' Pitch: 25' j Monitoring System: SunPowef ` PanevArray. SpaeMications: - - 5 Panel: SwPower 250w Blade Racking: UniRac SunFrams \ r T Panel: 61.39"X 31.42' Array: 184.17'X 98.76' Surface: 255"X 113' Magic: 32.17' i ...Lagand: 5 Sw ower 250W Panel - UniRac SunFrame Rail • 15 Eco-Fasten Quickfool 2X6' True Douglas Fir Rafter 24' O.C. Notes: 5 Number of Rod Layers: 1 Height above Roof Surface: 4' Materials Used: Ec Fasten. UniRac, Sunpower. PowerOne Added Roof load of PV System: 3.6psf EnglnserfArchitact Seat: OF NE 4Q H PAS 0 l *y ~ ot:~'p 1u Ntnq0 OgB182 -9p-FESStONP~~ Dravmn By: DRV Drawing a 9 of 11... ( Date: 10/4113 REV' A ;Drawing Style: 318' = 1.0' Gi ?GREENLOGICO ENERGY Green Logic, LLC Approved 18" walkway ..rim DAddarlo 8980 Peconc Bay Blvd Laurel NY, 11948 - Toral System Size O.Skyv 2 strings or 7 and 1 sting or 10 on SPR6000p 1 Sting of 5 and 1 string of 5 on SPR-3000p 5 SunPower 250w Panels - - - - - Azimuth: I Pitch: I ~ Monitoring System: D j SunPower PaneYArray Speeifkatiom• i + 18" walkway Panel: SunPower 250w Black i Racking: UniRac SunFrame i Panel: 61.39"x 31.42" I ~ i Legend: SunPower 250W Panel 15 SunPower 250w - UniRac SunFrame Rail ? panels • 64 Eco-Fasten Duck Foot 2x6- True Douglas Fir Rafter 24" 4 O.C. Notes: Number of Roof Layers: 1 Height above Roof Surface: 4" \ Materials Used: Eco-Fasten, UniRac, SunPower, Frenus, PowerOne Added Roof load of PV System: 3.5psf En91n SwL ~~OF NEtyy ~P t~,P~ 09 14 SunPower 250w •y ~L+O panels # W Z~~~a X881 B . - ~2d 2 PowerOne inverters 9~FEss10Np~ adjacent to Main electrical panel. Drawn B-- Drew g01o0f11 Date: 1014113 REV: A Drawing Scale: Y32--- 1.01 _ I CtGREENLOGICO: ENERGY r reenLogic. LLC Approved Jim D'Addario 8980 Peconic Bay Blvd Laurel NY, 11948 Total System Sae: 8.5kW 2 strings of 7 ant! 1 string of 10 on SPRe00op 1 sbing of 5 and 1 strng of 5 on SPR.3000p Azimuth: Pitch: _ Monitoring System:... _i . SunP"er Mateml list 9tY Rail Material list parte9Array SpeeHicatlons: EarFashnQuick Foot Base Pate 54 Panel:SunPower250wBlack Racking: UniRac SunFrame Eca-FastenQuick Foot Aluminum Necks 54 IPanel: 61.39"x31.a2' Eco-FastenQuick FootFlashings 54 g14-130YI)PIConcealeckcew 108 Legend: I~ SunPOwer 250W Para31 Uniltac SunFrame Rail • 54 Eco-Fasten Quick Foot B p 247 True Douglas; Fir Rafter 24' G Q.C. Notes: Number of Roof Layers: 1 Height above Roof Surface: 4" Materials Used: Eco-Faslen, UniRac. Sunpower, Fmnius, PowerOne Added Roof load of PV System: 3.5psf Enga Rest Seal: of: NEW a r ~ y~~0 ~BB1BZ ~?O p9~FESSI • Drawn By: DRV Drawing OF 11 of 11 Date: 1014113 REV' A Drawing Scale: 3/32"= 1. Or