HomeMy WebLinkAbout38643-Z
yyFF9I f Town of Southold Annex 4/3/2014
P.O. Box 1179
54375 Main Road
'ffi! Southold, New York 11971
f
CERTIFICATE OF OCCUPANCY
No: 36844 Date: 4/3/2014
THIS CERTIFIES that the building SOLAR PANEL
Location of Property: 8960 Great Peconic Bay Blvd, Laurel,
SCTM 473889 Sec/Block/Lot: 126.-5-6
Subdivision: Filed Map No. Lot No.
conforms substantially to the Application for Building Permit heretofore filed in this officed dated
1/15/2014 pursuant to which Building Permit No. 38643 dated 1/27/2014
was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for
which this certificate is issued is:
roof mounted solar panels on an existing one family dwelling as applied for.
The certificate is issued to D'addario, James & D'addario, Janet
(OWNER)
of the aforesaid building.
SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL
ELECTRICAL CERTIFICATE NO. 38643 3/20/14
PLUMBERS CERTIFICATION DATED
Authorized Signature
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
TOWN CLERK'S OFFICE
$9 SOUTHOLD, NY
BUILDING PERMIT
(THIS PERMIT MUST BE KEPT ON THE PREMISES
WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS
UNTIL FULL COMPLETION OF THE WORK AUTHORIZED)
Permit 38643 Date: 1/27/2014
Permission is hereby granted to:
D'addario, James & Daddario, Janet _
45 Clock Tower Ln
Old Westbury, NY 11568
To: Installation of solar panels as applied for.
At premises located at:
8960 Great Peconic Bay Blvd, Laurel
SCTM # 473889
Sec/Block/Lot # 126.-5-6
Pursuant to application dated 1/15/201 and apn~'
ild
ing Inspector.
To expire on 7129/2015.
Fees:
ANELS $50.00
CO - ADDITIONS TO ACCESSORY BUILDINGS $50.00
Total: $100.00
Building Inspector
Form No. 6
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
TOWN HALL
765-1802
APPLICATION FOR CERTIFICATE OF OCCUPANCY
This application must be filled in by typewriter or ink and submitted to the Building Department with the following:
A. For new building or new use:
1. Final survey of property with accurate location of all buildings, property lines, streets, and unusual natural or
topographic features.
2. Final Approval from Health Dept. of water supply and sewerage-disposal (S-9 form).
3. Approval of electrical installation from Board of Fire Underwriters.
4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of I% lead.
5. Commercial building, industrial building, multiple residences and similar buildings and installations, a certificate
of Code Compliance from architect or engineer responsible for the building.
6. Submit Planning Board Approval of completed site plan requirements.
B. For existing buildings (prior to April 9, 1957) non-conforming uses, or buildings and "pre-existing" land uses:
1. Accurate survey of property showing all property lines, streets, building and unusual natural or topographic
features.
2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is
denied, the Building Inspector shall state the reasons therefor in writing to the applicant.
C. Fees
1. Certificate of Occupancy - New dwelling $50.00, Additions to dwelling $50.00, Alterations to dwelling $50.00,
Swimming pool $50.00, Accessory building $50.00, Additions to accessory building $50.00, Businesses $50.00.
2. Certificate of Occupancy on Pre-existing Building - $100.00
3. Copy of Certificate of Occupancy - $.25
4. Updated Certificate of Occupancy - $50.00
5. Temporary Certificate of Occupancy - Residential $15.00, Commercial $15.00
Date. 111 311 y
New Construction: Old or Pre-existing Building: x (check one)
Location of Property: 8960 Great Peconic Bay Blvd Laurel
House No. Street Hamlet
Owner or Owners of Property: James D'Addario
Suffolk County Tax Map No 1000, Section 126 Block 5 Lot 6
Subdivision Filed Map. Lot:
Permit No. Date of Permit. Applicant: GreenLo9ic LLC
Health Dept. Approval: Underwriters Approval:
Planning Board Approval:
Request for: Temporary Certificate Final Certificate: x (check one)
Fee Submitted: $ 50.00
76knt Signature
rjf S 0
Town Hall Annex Telephone (631) 765-1802
54375 Main Road Fax (631) 765-9502
P.O. Box 1179 0~
45k rog
Southold, NY 11971-0959 - e r. riche rt(o)town. so uthold. ny. us
Z2
coumN
BUILDING DEPARTMENT
TOWN OF SOUTHOLD
CERTIFICATE OF ELECTRICIAL COMPLIANCE
SITE LOCATION
Issued To: D'Adclano
Address: 8960 Peconic Bay Blvd City: Laurel St: NY Zip: 11948
Building Permit* 38643 Section: 126 Block: 5 Lot: 6
1 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE
lContractor: DBA: Green Logic LLC License No: 43858-me
SITE DETAILS
Office Use Only
Residential Indoor Basement Service Only
Commerical Outdoor 1st Floor Pool
New Renovation 2nd Floor Hot Tub
Addition Survey n Attic Garage
INVENTORY
Service 1 ph Heat Duplec Recpt Ceiling Fixtures HID Fixtures
Service 3 ph Hot Water GFCI Recipt Wall Fixtures Smoke Detectors
Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors
Sub Panel A/C Blower Range Recpt Fluorescent Fixture Pumps
Transformer Appliances Dryer Recpt Emergency Fixtures Time Clocks
Disconnect Switches Twist Lock Exit Fixtures TVSS
Other Equipment: roof mounted PHOTOVOLTAIC SYSTEM to include, 34 Sun Power SPRA20-250
modules, 1 -Sun Power SPR6000 & 1 -Sun Power SPR3000 inverters. (8,50OWatts)
Notes:
Inspector Signature: Date: March 20 2014
81-Cert Electrical Compliance Form.xis
~f ~O~~,OF SOUry„
TOWN OF SOUTHOLD BUILDING DEPT.
765-1802
INSPECTION
[ ] FOUNDATION 1ST [ ] ROUGH PLEIG.
[ ] FOUNDATION 2ND [ ] INSULATION
[ ] FRAMING / STRAPPING [ ] FINAL
[ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION
[ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION
( ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL)
REMARKS:
DATE INSPECTOR r
Pacifico Engineering PC Engineering Consulting
700 Lakeland Ave, Suite 2B Ph: 631-988-0000
Bohemia, NY 11716 Fax: 631-382-8236
P
www.pacificoengineering.com ~N Gc solar@pacificoengineering.com
March 11, 2014
Town of Southold
Building Department
54375 Route 25, P.O. Box 1179
Southold, NY 11971
Subject: Solar Energy Installation for
James D'Addario Section: 126
8960 Peconic Bay Blvd Block: 5
Laurel, NY 11948 Lot: 6
1 have reviewed the solar energy system installation at the subject address. The units have been installed in
accordance with the manufacturer's installation instructions and the approved construction drawing. I have
determined that the installation meets the requirements of the 2010 NYS Building Code, and ASCE7-05.
To my best belief and knowledge, the work in this document is accurate, conforms with the governing codes
applicable at the time of submission, conforms with reasonable standards of practice, with the view to the
safeguarding of life, health, property and public welfare.
Regards,
Ralph Pacifico, PE
Professional Engineer
r
b
ZsFO oea~ez ~~e
AgOFESS'tO~P
Ralph Pacifico, ro essional Engineer
NY 066182 / NJ 24GE04744306
FIELD ON REPORT DATE COMMENTS
~~ro
a
FOUNDATION (1ST)
-C a
FOUNDATION (ZND)
ck,o
y
Cj
ROUGH FRAMING & y
PLUMING
E
r
INSULATION PER N. Y. H
STATE ENERGY CODE
T
c
• r
FINAL
AD ITIONAL COMMENTS
31
Fe. do Lj
~tz
TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST
BUILDING DEPARTMENT Do you have or need the following, before applying?
TOWN HALL Board of Health
SOUTHOLD, NY 11971 4 sets of Building Plans
TEL: (631) 765-1802 Planning Board approval
FAX: (631) 765-9502 Prr ffc~~ Survey
SoutholdTown.NorthFork.net PERMIT NO.E- Check
Septic Form
N.Y.S.D.E.C.
Trustees
Flood Permit
Examined 1 7 2011 I r Storm-Water Assessment Form
JA N 15 2014 contact:
Approved I 1 t / 120 (u Mail to: GreenLogic LLC
Disapproved a/c 425 County Road 39A, Southampton, NY 11968
Phone: 631-771-5152
Expiration 7 19 , 20 1
But ding APPLICATION FOR BUILDING PERMIT
3
INSTRUCTIONS Date 20ff-
a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4
sets of plans, accurate plot plan to scale. Fee according to schedule.
b. Plot plan showing location of lot and of buildings on premises, relationship to adjoining premises or public streets or
areas, and waterways.
c. The work covered by this application may not be commenced before issuance of Building Permit.
d. Upon approval of this application, the Building Inspector will issue a Building Permit to the applicant. Such a permit
shall be kept on the premises available for inspection throughout the work.
e. No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector
issues a Certificate of Occupancy.
f Every building permit shall expire if the work authorized has not commenced within 12 months after the date of
issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the
property have been enacted in the interim, the Building Inspector may authorize, in writing, the extension of the permit for an
addition six months. Thereafter, a new permit shall be required.
APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the
Building Zone Ordinance of the Town of Southold, Suffolk County, New York, and other applicable Laws, Ordinances or
Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The
applicant agrees to comply with all applicable laws, ordinances, building code, housing code, and regulations, and to admit
authorized inspectors on premises and in building for necessary inspections.
GreenLogic LLC
(Signature of applicant or name, if a corporation)
425 County Road 39A, Southampton, NY 11968
(Mailing address of applicant)
State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder
Contractor
Name of owner of premises James D'Addario
(As on the tax roll or latest deed)
If applicant is corporation, signature of duly authorized officer
(Name and t e of corporate )
Builders License No. 40227-H
Plumbers License No.
Electricians License No. 43858-ME
Other Trade's License No.
1. Location of land on which proposed work will be done:
8960 Great Peconic Bay Blvd Laurel
House Number Street Hamlet
County Tax Map No. 1000 Section 126 Block 5 Lot 6
Subdivision ` .Filed.Map No. Lot
2. State existing use and occupancy of premises and intended use and occupancy of proposed construction:
a. Existing use and occupancy Single family dwelling
b. Intended use and occupancy Single family dwelling
3. Nature of work (check which applicable): New Building Addition Alteration
Repair Removal Demolition Other Work Roof mounted solar electric system
(Description)
4. Estimated Cost $33,724.00 Fee
(To be paid on filing this application)
5. If dwelling, number of dwelling units Number of dwelling units on each floor
If garage, number of cars
6. If business, commercial or mixed occupancy, specify nature and extent of each type of use.
7. Dimensions of existing structures, if any: Front Rear Depth
Height Number of Stories
Dimensions of same structure with alterations or additions: Front Rear
Depth Height Number of Stories
8. Dimensions of entire new construction: Front Rear Depth
Height Number of Stories
9. Size of lot: Front Rear Depth
10. Date of Purchase Name of Former Owner
11. Zone or use district in which premises are situated
12. Does proposed construction violate any zoning law, ordinance or regulation? YES NO X
13. Will lot be re-graded? YES_ NO X Will excess fill be removed from premises? YES_ NO_
8960 Great Peconic Bay Blvd
14. Names of Owner of premises James D'Addario Address Laurel, NY Phone No.
Name of Architect yarifirn FnyinaPrina P C Address700 Lakeland Ave. Bohemia, N1Phone No 631-gRR-nnn0
Name of Contractor GreenLogic LLC Address 42S Cmmty Rnad 351A Phone No. 631-771-5152
Southampton, NY 11968
15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO
* IF YES, SOUTHOLD TOWN TRUSTEES & D.E.C. PERMITS MAY BE REQUIRED.
b. Is this property within 300 feet of a tidal wetland? * YES NO
* IF YES, D.E.C. PERMITS MAY BE REQUIRED.
16. Provide survey, to scale, with accurate foundation plan and distances to property lines.
17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey.
18. Are there any covenants and restrictions with respect to this property? * YES NO
* IF YES, PROVIDE A COPY.
STATE OF NEW YORK)
SS:
COUNTY OF Suffolk )
Nesim Albukrek being duly swom, deposes and says that (s)he is the applicant
(Name of individual signing contract) above named,
(S)He is the Contractor
(Contractor, Agent, Corporate Officer, etc.)
of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;
that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be
performed in the manner set forth in the application fil
~0. Hp
Swo` m to before me thi o o ex, 2% 90
h~dayof (Q 20~ o oo%ap Y
1
CMMI AVBLIC 0 tAAIA~
Notary Public `oG do Rog Signature of Applicant
yry'STATE
J ~ 'A-AAA'
Scott A. Russell WO James A. Richter, R.A.
SUPERVISOR Michael M. Collins, P.E. too SOU11iOID TOWN HAIL- P. 0.13 ~ 1179 ~j $3095 M R"A-SOMMLD. NEW YORK 11
Telephone I: (631) - 765 -1560c 7
MICHARGC0I.U Wr0 M.SOU1730IDNY.US J
Office of the Engineer JAN 17 2014 D
Town of Southold
STORMWATER MANAGEMENT CONTROL PLAN LHET
(TO BE COMPLETED BY THE APPLICANT)
TO: ENGINEERING DEPARTMENT AMSBATTALA71B ATIAIM LVa&Mls or RW;VIPIHTIAV.•
FROM BUILDING DEPARTMENT ? COPY of completed Application for
Building Permit
DATE:
? Storrnwater Management Control Plan
APPLICANT.: GreenLogic LLC
? Completed Chapter 236 Stormwater
S.C.T.M. 1000-126-5-6 Review Checldist
PROPERTY ADDRES& 8960 Peconic Bay Blvd, Laurel, NY 11948
BRIEF PROJECT DESCRIPTION: Roof mounted solar electric system
D~FI 1~(Ct ltd (!t' ~t2 I
]WO
FOR EN MG DEPARTMENT USE ONLY
RevieweLI Date ~ ` 1 7 -ti
i
® .
? Inrormation Required:
DATE:
CHAPTER 236 APPLIC"T. LLC
Storm'water Review Checklist S.C.T.M.#; 1000.126-5
• 1000-126-5-6
6
Stormwater Management Control Plan Requirements' Yes No PHYSICAL ADDRESS: 8960 Peconic Bay Blvd, Laurel, NY
NA
I • Plan drawn to scale of not leasthan b0 feet to the inch showing: If No or NA, Please Provide Additional Information
a. location and d Ofproperty.boundwiss x
b. total site acreage
c. existing and natural and man-made fanfares on and within 500 feet
of the site bout m . bed is 2365.17 2
d. test hole data indicating soil x and the
to water e. Proposed limits of clewing end theme total o}od~d
disturbance
f. existing and proposed coatouis ofthe site x
g. location of all existing and (mmnnum 2, interval) x
sidewalks pioposad stmctures, utilities roads, driveways,
and
h. spot IP'ade and finished floor elavations for
structures existing end Proposed
i, location of the swimming pool discharge ring
j. location of Proposed soil stockpile area(sy
k, location of the Proposed O2nahuction Mtn n staging areas x
x
I. location of the Proposed,concrM washout sib
m. location of all Proposed erosion and sediment control measures x
2. Plan includes caleulationa showing that the storm
water x
are sized to capture, store and h4lbute improvements
on-site NIIO 'all
im ervious surfaces e a two-inch rainfall
3. Detail drawings (pyy x
a. erosion and c provided for.
sediment comrola
b, contraction enUancc x
x
c. inlet structures (a•& catefi basins dmios, etc.)
d. leaching strttotures (e.g. on
besh ins, swa(esetc
REVISED 7/24/2013
,~0 6
Town Hall Annex #f +j)!r Telephone (631) 7651804
54375 Main Road (631) 7 5 Mio
P.O.Box1179 roger.richert t""tewnIS)E nVus
Southold, NY 11971-0959
"~UIII1,
BUILDING DEPARTMENT
TOWN OF SOUTHOLD
APPLICATION FOR ELECTRICAL INSPECTION
i
REQUESTED BY. Tamara Romero Date:
Company Name: creenLogic LLC
Name: Robert Skypala
License No.: 43858-ME
Address: 425 County Road 39A Southampton, NY 11968
Phone NO.:. 631-771-5152
JOBSITE INFORMATION: (*Indicates required information)
*Name: James D'Addario
*Address: R9Rn Paronir Ray Rlyd a r I NY
*Cross Street: Ray Aye
*Phone No.: 631-335-R197 .
Permit No.:
Tax Map District: 1000 Section: 126 Block: 5 Lot: 6
*BRIEF DESCRIPTION OF WORK (Please Print Clearty) Roof mounted solar electric system
34 SunPower SPR-X20-250 modules 8,500 Watts
1 SunPower SPR6000p & 1 SunPower SPR3000p
(Please Circle All That Apply)
*Is job ready for inspection: YES NO Rough In Final
*Do you need a Temp Certificate: _ YES NO
Temp Information (if needed)
*Service Size: 1 Phase 3Phase 100 150 200 300 350 400 Other
*New Service: Re-connect Underground Number of Meters Change of Service Overhead
Additional Information: PAYMENT DUE WITH APPLICATION
82-RequestforInspection Form
Gt GREENLOGICO
ENERGY
January 10, 2014
Town of Southold
Building Department
Town Hall
53095 Route 25
Southold, NY 11971
Dear Building Inspector:
Please find attached a building permit application on behalf of James D'Addario who has
engaged us to install a roof-mounted solar photovoltaic (PV) electric system at his home at
8960 Great Peconic Bay Blvd, Laurel, NY 11948.
In connection with this application, please find attached:
• Building Permit application
• A Storm Water Assessment Run-off Form
• Certificate of Occupancy Application
• 2 Surveys of the Premises
• 4 Engineer's Reports (2 originals and 2 copies)
• 2 One Line Electrical Schematics r)r
• 2 Spec. sheets of the solar panels (SunPower SPAQ)
• 2 Spec. sheets of the inverter (SunPower SPR6000p & SPR3000p)
• 2 Code Compliant Manuals for Racking System
• GreenLogic Suffolk County Home Improvement License
• GreenLogic Certificate of Liability Insurance
• GreenLogic Certificate of Worker's Compensation Insurance Coverage
• Installation Manager's Master Electrician's License
• Check for $100 ($50 Building Permit/$50 CO)
• Application for Electrical Inspection with a check for $100
Please let us know if you need anything else in connection with this application.
Yours truly,
Tamara Romero
Account Manager
GreenLogic LLC
631-771-5152 ext. 120
GREEN LOG IC, LLC • www_GreenLogic-coin Tel: 877.771.4330 Fax: 877.771.4320
SOUTHAMPTON ROSLYN HEIGHTS
425 County Rd. 39A 200 S. Service Rd., #108
Southampton, NY 11968 Rosyln Heights, NY 11577
G ~?GREENLOGIC"
ENERGY
March 27, 2014 F
The Town of Southold J,"I
Building Department U 2D14
54375 Route 25
P.O. Box 1179
Southold, NY 11971
Re: Building Permit No. 38643
James D'Addario
8960 Peconic Bay Blvd, Laurel, NY
To the Building Inspector:
Enclosed please find the Engineer's Certification Letter for James D'Addario's solar
electric system, which we installed at the above reference address. Please arrange to
send him the Certificate of Occupancy and close out the building permit. Please let me
know if you have any questions about the installation.
Sincerely,
Tamara Romero
Account Manager
GreenLogic LLC
631-771-5152 Ext. 120
GREENLOGIC. LLC • www.GreenLogic.com Tel: 877.771.4330 Fax: 877.771.4320
SOUTHAMPTON ROSLYN HEIGHTS
425 County Rd. 39A 200 S- Service Rd., 4108
Southampton. NY 11968 Rosyln Heights , NY 11577
r
2 PROPOSED NEW SEPTIC SYSTEM
1 - 1000 qaL PRECAST SEPTIC TAW
1 - 101 • S 'DEEP LEACMNG POOL
WITH 3' SAND (SN COLLAR 3'
ABOVE GROUND WATER
h - - @ RR MOWED AhTIC REPSYSTEM LACED IN PLACE
C G
awl
y 'U + 0" 14
II P ! - Z It
Y:
L `O"
u
OT • u r
SURVEY OF v2 s z
LOT 6
( FLORENCE G. DOWNS) 0~J t
_ co
MAP OF PROPERTY OF A. L. DOWNS " J' I 3
FILED AU6. 14,NR2* AS'MAPNO. 21
AT LAUREL ~ 14f1EA 20,012 y4ff, to No ikle : . 'M . .
TOWN OF SOUTHOLD z
SUFFOLK COUNTY, M.Y. `t
.1000-424- 05-06
oF~eriy SCALE:1°=40'
6~4te S MET C ;t SENT 29,1986
Bois' Fy Dec. 29, 1993 floundamw
* AVA 16,1999 f Tie Dk/arcel CERTWIND Al To:
•tq,1i~MU00 _ 7M #E MIIIt70G16if frMTfR, INC.
MARYaF/
JA1yt~,Eyy~~,, tOOi ~ CM#C"O 77TLE IiWWRANCE COMPANY
e *8 WANT" a
1°" PEMiVS ,&STRACT, INC.
N.Y,S LIG NO. 4908 - - Oo\,
fL3/) 765 - SOLO FX~83V1 765- /797 - G
P~ \
. a am 909
230. TRAVELER STREET
At Y. 0971
1
Pacifico Engineering PC _ Engineering Consulting
700 Lakeland Ave, Suite 2B Ph: 631-988-0000
Bohemia, NY 11716 - P Fax: 631-382-8236
.~~a solar@pacificoengineering.com
www.pacifccengineering.comP!41
January 7, 2014
Town of Southold , w
Building Department VED AS NOTED
c 1r t1-~
APR
54375 Route 25, P.O. Box 1179 /y (r3~
Southold, NY 11971 r DATE: 2 B.P.
Subject: Solar Energy Installation for FEE
James D'Addario Section: ItNT :y s'.--
8960 Peconic Bay Blvd Block: 57a-, 2 ,ti
Laurel, NY 11948 Lot: 8rN
COVI'L`( VaI ; H ALL CODES OF
NEW YORK STA; ~ L-: & TOWN CODES FGr; rvU
AS REQUIRED AN' not InITION OF 2. ROUGH FRAIMiNu & PLUi~1BING
3. INSULATION
cnl r rl n m 4. FINAL - CONSTRUCTION MUST
-ET THE
I have reviewed-tWrobfi ucture at ilia subject address. The structure G9M0p6fl tQCtWWhI all { ht~ OHS.
the roof mounted system. The units are to be installed in accordance with the manufacturer's installation
instructions. I have determined that the installation will meet the requirements of the 2010 NYS Building Code,
and ASCE7-05 when installed in accordance with the manufacturer's instructions.
Roof Section A B C
Mean roof height 19 ft 13 ft 19 ft
Pitch 4114 in/12 7 1/21n/12 51/2 in/12
Roof rafter 2x6 2x6 2x6
Rafter spacing 24 inch on center 24 inch on center 24 inch on center
Reflected roof rafter span 7.1 ft 10.4 ft 5.8 ft RETAIN STORM WATER RUNOFF
Table R802.5.1(1)allowablemax 10.8 ft 10.8 It 10.8 ft PURSUANT TO CHAPTER 236
The climactic and load information is below: OF THE TOWN CODE.
CLIMACTIC AND Wind Live load,
GEOGRAPHIC DESIGN Category Snow Load, sec gust, ASCE 7, pullout , to Fastener type
CRITERIA Pg mph pat load, to
Roof Section A C 20 120 61 1249 (2) #14-13 x4.5" DP1 Concealer
Screws
B 33 676 (2) #14-13 x4.5" DPI Concealer
Screws
C 61 639 (2) #14-13 x4.5" OPi Concealer
Screws
Weight Distribution Q,~{r
array dead load 3.5 p
load per attachment 440.00 p
USE IS UNLAWFUL
Ralph Pa PE WITHOUT CERTIFICA
Professional l Engineer d'
OF OCCUPANCY ph
W 066182 E04744306 I
?GREENLOGIC
ENERGY
GreerlLogto. LLC Approved
Jim D'Addarlo
8960 Peconic Bay Bhd
Laurel NY, 11948
Surface i1:
Total System Size: B.SkW
i May Size: 3.5kW
2 stings of 7 and f string of 10 on SPR-
6000p (shared with surface 2)
x Azimuth: 204'
Pitch: 20*
Monitoring Sysb
SunPOwer eer 111
Panel/Array 9peN0eatlons:
Panel: SunPower 250w Blade
Reciting: Uniftac SunFrame
Panel: 61.39" X 31.42"
Array: 157.1"X 188.67'
Surface: 195.5"X 216"
\ \ Maglc1i: 62.14'
Legend:
V \i ® SuMover 250VV Panel
- UniRac SunFrame Rail
• 18 Eco-Fasten Duickfoot
2x8" True Douglas F6 Rafter 24'
D.C.
Notes:
Number of Roof Layers: 1
Height above Roof Surface: 4"
Materials Used: Eco-Fasten, UniRac,
Sunpower. Fmnius
Added Roof Wad of PV System: 3.5psf__
A En
SaaY
OP NEWS .
Cal
~ w
:'i~ ys o
~O aQ81
pq~FESS\~N~~
Drawn By: DRV Drawing # 1 of 11
Date: 1014113 REV: A
Drawing Scale: 1/4"= 1.0'
CtGREENLOGIC®j
ENERGY
Greentogk, LLC Approved
Jim D'Addario
8960 Peconic Bay Blvd
Laurel NY, 11948
\ Surface #1:
Total System Size: 8.5kW
O May Size: 3.5kW
2 strings of 7 and 1 slrkg of 10 on SPR-
6000p (shared with surface 2)
Azimuth: 204°
Pilch: 20°`
\ Monitoring System:
i SunPower
ParrWArray SpecBicatlona: -
i Panel: Sur Power 250w Black
Racking: UniRac SunFrame
Panel: 61.39"X 31.42"
Array: 157.1"X 188.67"
y Surface: 195.5" X 216"
Magic 82.14'
l.egend• I
\ SunPower 250W Panel
UNRac SunFrame Rail
• 18 Eco-FaMen Ouickfoot
f' \ 2x8 True Douglas Far Railer 24"
O.C.
Notes:
j
[A ~Vrj Number of Roof Layers:1
Height above Roof Surface: 4"
Materials Used: Eco-Fasten, UniRac,
Sunpower, Froriua
Added Roof bad of PV
~ System: 3.5psf
\ EnglneedArchitect Seal:
~pF NEyr y
x
Z~ .off' O ~
AAA veste'd'
Drawn 4 DRV Drawing #20f 1
Dale: 10/0/4/13 REV: A
Drawing Scale: 1/4" = 1.0'
~i ?GREENLOGICeI
ENERGY
GrwswLogl, LLC Appoved
Jim D'Addario
8960 Peconic Bay Blvd
Laurel NY, 11948
_ Surfsca t1:
Total System Size: 8.5kW
Ci 0 Array Size: 3.5kW
2 strings of 7 and 1 a" of 10 on SPR-
_ 60DDP (shared with surface 2)
Pitch:
i Pdch: 20° ~
2 rT\/ Azimuth:
Monitoring System:
SunPower
PanDUArmy Specifications:
Panel: SMPOeer 25Uw Blade
Racking: Un[Rac SunFrame
Panel 61.39' X 31.42"
Array: 157X X X 188.67'
Surface: 195.5"X216'
Magic a: 62.14',
Legend:--
; L
- ® SunPower 250W Panel
1 2 - UniRac SunFrame Rai
• 18 Ecofasten Oniekfool
a 2x8" True Douglas Fir Railer 24"
o O.C.
Notes:
Number of Root Layers: 1
Height above Roof Surface: 4"
Materials Used: Eco-Fasten, UniRac,
Sunpower, Fronius
/ Added Roof bad of PV System: 3.5psf
EuplnearfArchhacl SW:
pp NE6{r
1 ,`P~~N PO9~
rijvey
77
I /
FO ~8818'Z ~fi
AR~FESs1
Drawn By: DRV Drawing 0 3 of 11
Date: 1014113 REV: A
Drawing Style: 1/4"= 1.0'
C GREENLOGICa
ENERGY
GTaanLoylc, LLC Approved
Jim D'Addado
8960 Peconic Bay Blvd -
Laurel NY, 11948
Surlaca R2:
Total Syarem Sim: e5kW _..-l
May Size: 3.75kW
1 string of 10 oa SPR6000p(Nramd with surface
i
)
1string of 5 m SPR3000p(shared with sudace 3)
- . • Azimuth: 204° _
Pitch: 32* Mangodng System:
\ SunPower
X I PanellArray yitclBcations:
Panel: Sunl` w 250w Blade
Racking: UniRac SunFrame
Panel: 61.39" X 31.42"
Array: 220.84" X 188.52"
Surface: 261' X 234'
I
-------J Magic*: PORTSCAPE
Legend:
1441 SunPower 250W Panel -
- UniRac SunFrame Rail
i I • 21 ECO•Fasten Quickfoot
6 9 2x8" True Douglas Fir Rafter 24"
O.C.
Notes:
Number of Roof Layers: 1
\ Height above Roof Surface: 4"
i \ Materials Used Eco-Fasten, UniRac.
\ i \ Sunpower, PowerOne
Added Roof load of PV System: 3.5psf
i \ Engln Seal:
i OF NE{yY
t
r
n
~~OA o819%
9~FESSION*
Drawn BY DRV Drawing i4 of 11
Date: 10/4/13 REV: A
Drawing Scale: 1/4"Scale: 1/4" = 1.0'
C GREENLOGICe
ENERGY
GreenLo9k, LLC Approved -
I Jim D'Addario
8900 Pec0niC Bay BNd
Lawel NY, 11948
.
Surface X2:
Total System Sae: 9.SkW
ray Sae3.75kW
Ar
1 sMng of 10 on SPRa000p(shomd wah surface
1 string of 5 on SPR3000p(shared with surface 3) i
Azimuth: 204°
Pitch: 3Y MoNtpkg System:
SunPower
Pan WArray9peci0cafcets:_
Panel: SunPower 25Dw Bieck -
Racking: UniRac SunFrame
Panel: 81.39" X 31.42'
Tv
/
/ Array: 220.84" X 188.52'
i Surface: 281" X 234'
I Magicd: PORTSCAPE
Legend:
_ _ ~}}J SwlPower 25OW Panel
i / - UNRac SunFrame Rail
% \ - • 21 Eco-Fasten Quickfoot
B 2x8" Tme Douglas Fir Rafter 24"
O.C.
Notes:
Number of Roof Layers: 1
Height above Roof Surface: 4"
I Materials Used: Eco-Fasten, UnlRac,
Sunpower, PowerOne
Added Roof bad of PV System: 3.5psf
Engineer/Architect Seal:
F NE{yY
1P O
BOA 888182 Q~
9~FESSI
Drawn By: DRV_ I Drawing 0 5 of 11 -
Date: 1014113 REV: A
Drawing Scale: V4" - 1.0'
CfGREENLOGICO
ENERGY
_GrawaLogic, LLC Approved
Jim D'Addedo
8960 Peconle Bay Blvd
Laurel NY. 11948
Surface _i_2: _ _ _i
TOM System Sim: 8.5kW l
Array Size: 3.75kW
1 shing of 10 on SPR6000p(shamd with sudam
1)
4 - 1 string on 3000IX with surface Azimuth: 204'
Pitch: onitoring System:
- - /
M
, SunPower
PamilArray t pacification:
I Panel: SunPower 250w Black
L' Racking: tlniRac SunFrame
3 4 Y Panel: 61.39'X 31.42'
Array: 220,W X 188.52"
. / Surface: 261"X 234'
r Magic#: PORTSCAPE
Legend:
SunPo
POwer 250W Panel
UniRaC SunFrame Rail
• 21 Eco-Fasten Ouickfoot
3 B B 2x6' True Douglas Fir Rafter 24'
O.C.
Notes:
\ Number of Roof Layers: 1
Height above Roof Surface: 4"
Materials Used: Eco-Fasten. UniRac,
Sunpower, PowerOne
Added Roof load of PV System: 3.5psf
\ __EriginwrlArchiuet Seal: I
73 OF NE6y
PAO/F
I 'O
,j
Is $
Z 2
FO Is 4.~
s O
A9~FES
Drawn By: DRV ng # 6 of 11
Date: 1014/13 REV: A
Drawing Scale: 1/4" =1.0'
~i ?GREENLOGICe1
ENERGY
GreenLogrc, LCC Approved
Jim D'Addado
8980 Peconic Bay Blvd
Laurel NY, 11948
Surface 0:
Total System Size: 8.5kW
Army Size: 1.25kW
1 string of 5 and 1 string of 5 on SPR-
3000p(shamd with Surface 2)
Azirmth: 122°
Pilch: 25°
Monitadng System:
- SwPower
PanallArray Specifications: _
Panel: SunPower 250w Black
Racking: UniRac SunFrame
Panel: 51.39' X 31.42'
Array: 184.17'X 98.78'
Surface: X 113'
Magic a_ 32.1 7"
_ Legend: -
SunPower Aim-0am _
- UniRac SunFrame Rail
• 15 EcoFasten Ouickfoot
/ 2x8° True Douglas Fir Rater 24'
O.C.
Notes:
Number of Roof Layers: 1
Height above Roof Surface: 4"
Materials Used: Eco-Fasten, UniRac,
Sunpower, PowerOne
Added Roof load of PV System 3.5psf
EnglovedArchitecl Seal:
of NEy,r
y ae.
r-
w
Z ~
~~FESSI
Drawn By: DRV Drawing • 7 of 11
Date: 1,0/ : REV: A
DrawinScale: 3f8'.=„ 1.0' _ I
C GREENLOGICo
ENERGY .
GmwLogk, LLC Approved
Jkn D'Addario
8960 Peconic Bay Blvd
Laurel NY, 11948
Surface 03:
Total System Size: 8.5kW
Array Sae: 125kW
1 string of 5 and 1 string of 5 on SPR-
3000p(shered with Surface 2)
Azimuth: 122°
Pitch: 25°
2
~ Monitoring System:
j SunPower !
Pano
rrlaUona:
Panel: SunPower 2 250w 0w Blakack
Racking: UrdRac SwFrame
Panel: 61.39' X 31.42'
Array: 184.17° X 98.76"
/ Surface: 255" X 113'
Magic 32.17"
_Legsnd:
E14] SunPOwer 25001Panel
Unitac SunFrarne Red
• 15 Eco-Fasten Oulckfoot
/ g 8 2x6" Two Douglas Fir Rafter 24"
Y O.C.
Notes:
Number of Roof Layers: 1
Height above Roof Surface: 4"
Materials Used: FCo-Fasten, UNRac,
Sunpower, PowerOne
Added Roof load of PV System: 3.5psf
Englneed Itect Seat
OF Ne
,r,P N PA~~ p
C
i
• 2
`~°,o es~s2~ o
9~FfSS10~~P~ _
Drawn By: DRV Drawing • 8 0111
Date: 1014113 REV: A
Drawing Scale: 318"= LO'
IctGREENLOGIC~
ENERGY
GneenLoglc, LLC Approved
Jim D'Addario
8960 Peconic Bay Blvd
Laurel NY, 11948
Srface 03;
Total System Size: 8.5kW -
Array Size: 1.25kW
1 string of 5 and 1 String of 5 on SPR-
3000p(shered with Surface 2)
Azimuth: 122'
Pitch: 25'
j Monitoring System:
SunPowef
` PanevArray. SpaeMications: - -
5 Panel: SwPower 250w Blade
Racking: UniRac SunFrams
\ r T Panel: 61.39"X 31.42'
Array: 184.17'X 98.76'
Surface: 255"X 113'
Magic: 32.17' i
...Lagand:
5 Sw ower 250W Panel -
UniRac SunFrame Rail
• 15 Eco-Fasten Quickfool
2X6' True Douglas Fir Rafter 24'
O.C.
Notes:
5 Number of Rod Layers: 1
Height above Roof Surface: 4'
Materials Used: Ec Fasten. UniRac,
Sunpower. PowerOne
Added Roof load of PV System: 3.6psf
EnglnserfArchitact Seat:
OF NE
4Q H PAS 0
l *y ~ ot:~'p
1u
Ntnq0 OgB182
-9p-FESStONP~~
Dravmn By: DRV Drawing a 9 of 11...
( Date: 10/4113 REV' A
;Drawing Style: 318' = 1.0'
Gi ?GREENLOGICO
ENERGY
Green Logic, LLC Approved
18" walkway ..rim DAddarlo
8980 Peconc Bay Blvd
Laurel NY, 11948 -
Toral System Size O.Skyv
2 strings or 7 and 1 sting or 10 on SPR6000p
1 Sting of 5 and 1 string of 5 on SPR-3000p
5 SunPower 250w Panels
- - - - - Azimuth:
I Pitch:
I ~ Monitoring System:
D j SunPower
PaneYArray Speeifkatiom•
i
+ 18" walkway Panel: SunPower 250w Black
i
Racking: UniRac SunFrame
i Panel: 61.39"x 31.42"
I ~
i
Legend:
SunPower 250W Panel
15 SunPower 250w - UniRac SunFrame Rail
? panels • 64 Eco-Fasten Duck Foot
2x6- True Douglas Fir Rafter 24"
4 O.C.
Notes:
Number of Roof Layers: 1
Height above Roof Surface: 4"
\ Materials Used: Eco-Fasten, UniRac,
SunPower, Frenus, PowerOne
Added Roof load of PV System: 3.5psf
En91n SwL
~~OF NEtyy
~P t~,P~ 09
14 SunPower 250w •y ~L+O
panels #
W
Z~~~a X881 B . - ~2d
2 PowerOne inverters 9~FEss10Np~
adjacent to Main
electrical panel. Drawn B-- Drew g01o0f11
Date: 1014113 REV: A
Drawing Scale: Y32--- 1.01
_
I
CtGREENLOGICO:
ENERGY
r reenLogic. LLC Approved
Jim D'Addario
8980 Peconic Bay Blvd
Laurel NY, 11948
Total System Sae: 8.5kW
2 strings of 7 ant! 1 string of 10 on SPRe00op
1 sbing of 5 and 1 strng of 5 on SPR.3000p
Azimuth: Pitch: _
Monitoring System:... _i
. SunP"er
Mateml list 9tY Rail Material list parte9Array SpeeHicatlons:
EarFashnQuick Foot Base Pate 54 Panel:SunPower250wBlack
Racking: UniRac SunFrame
Eca-FastenQuick Foot Aluminum Necks 54 IPanel: 61.39"x31.a2'
Eco-FastenQuick FootFlashings 54
g14-130YI)PIConcealeckcew 108 Legend:
I~ SunPOwer 250W Para31
Uniltac SunFrame Rail
• 54 Eco-Fasten Quick Foot
B p 247 True Douglas; Fir Rafter 24'
G Q.C.
Notes:
Number of Roof Layers: 1
Height above Roof Surface: 4"
Materials Used: Eco-Faslen, UniRac.
Sunpower, Fmnius, PowerOne
Added Roof load of PV System: 3.5psf
Enga Rest Seal:
of: NEW
a
r ~
y~~0 ~BB1BZ ~?O
p9~FESSI
• Drawn By: DRV Drawing OF 11 of 11
Date: 1014113 REV' A
Drawing Scale: 3/32"= 1. Or