Loading...
HomeMy WebLinkAbout37561-Z yjl Town of Southold Annex 11/26/2013 P.O. Box 1179 54375 Main Road i3 1 ¢ Southold, New York 11971 CERTIFICATE OF OCCUPANCY No: 36621 Date: 11/26/2013 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 1305 Bayview Ave, Mattituck, SCTM 473889 Sec/Block/Lot: 106.-6-20.4 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this officed dated 9/28/2012 pursuant to which Building Permit No. 37561 dated 10/4/2012 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: roof mounted solar panels on an existing one family dwelling as applied for. The certificate is issued to Goehringer, Gerard & Goehringer, Barbara (OWNER) of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 37561 12/4/12 PLUMBERS CERTIFICATION DATED Au thorized Signature TOWN OF SOUTHOLD yQ BUILDING DEPARTMENT TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit 37561 Date: 10/4/2012 Permission is hereby granted to: Goehringer, Gerard & Goehringer, Barbara PO BOX 812 Mattituck, NY 11952 To: construct an electric Solar Panel system to an existing dwelling as applied for At premises located at: 1305 Bayview Ave, Mattituck SCTM # 473889 Sec/Block/Lot # 106.-6-20.4 Pursuant to application dated 9/28/2012 and approved by the Building Inspector. To expire on 4/5/2014. Fees: SINGLE FAMILY DWELLING - ADDITION OR ALTERATION $50.00 CO - ALTERATION TO DWELLING $50.00 Total: $100.00 Building Inspector Form No. 6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new user L Final survey of property with accurate location of all buildings, property lines, streets, and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal (S-9 form). 3. Approval ofelectdcal installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead. 5. Commercial building, industrial building, multiple residences and similar buildings and installations, a certificate of Code Compliance from arebitect or engineer responsible for the building. 6. Submit 'Planning Bbard Approval of completed-site plan requirements. B. For existing buildings '(prior to-April 9, 1957)`non-conforming uses, or buildings and "pre-existing" land uses: 1. Accurate survey of property showing all properly lines, streets, building and unusual natural or topographic features. 2. A property completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied, the Building Inspector' shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy - New dwelling $50.00, Additions to dwelling $50.00, Alterations to dwelling $50.00, Swimming pool $50.00, Accessory building $50.00, Additions to accessory building$50.00,`Businesses $50.00. 2. Certificate of Occupancy on Pre-existing Building - $100.00 3. Copy of Certificate of Occupancy - $.25 4. Updated Certificate of Occupancy - $50.00 .5. Tempordry Certificate of Occupancy - Residential $15.00, Commercial $15.00 Date. 3 New Construction: Old or Pre-existing Building (check one) . Location of Property- HAal~ll ouse No. Street / Hamlet Owner or Owners of Property: I C6, lrs%1~, &Zj ~4 Suffolk County Tax M No 1000,'Section _7/ /J (I ' ':Block ~ Lot - Subdivision :Filed Map. Lot: Permit No. Date of Permit Applicant: Health Dept. Apprdvtil: UnderwritersApproval: Planning Board-Approval: . Request for. Temporary Certtficate Final Certificate: one) Fee Submitted: $ App cant Sig pF SOUTyolo Town Hall Annex Telephone (631) 765-1802 54375 Main Road Fax (631) 765-9502 P.O. Box 1179 a roger. richert(aD_town.southold.ny.us Southold, NY 1 1 971-0959 BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION Issued To: Gerry Goehringer Address: 1305 Bayview Ave City: Mattituck St: NY Zip: 11952 Building Permit* 37561 Section: 106 Block: 6 Lot: 20.4 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: Eastern Energy Systems License No: 47657-me SITE DETAILS Office Use Only Residential X Indoor Basement Service Only Commerical Outdoor 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey X Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures HID Fixtures service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Fluorescent Fixture Pumps Transformer Appliances Dryer Recpt Emergency Fixture Time Clocks Disconnect Switches Twist Lock Exit Fixtures TVSS Other Equipment: PHOTOVOLTAIC SYSTEM, 4900 watts, 20 Conergy 245 watt panels 2-Sunny Boy 2500 inverters Notes: Inspector Signature: Date: Dec 4 2012 81-Cert Electrical Compliance Form.xls Eastern "The Power of IndependenceT""' ENERGY SYSTEMS 7470 Sound Avenue Mattituck, NY 11952 vV^>va "'I 631.779.4004 fax 631.466.5200 10/9/12 COMPLIANCE OF INSTALLATION Project Name: Goehringer Customer Name: Jerry Goehringer Installation Address: 1305 Bayview Avenue, Mattituck, NY 11952 Applicant's License: 47657-ME Systems Info: 4,900 Watt Solar PV System with 20 Conergy 245 Watt Solar Panels and 2 SMA Sunny Boy 250005 Inverters It has been inspected and the electrical and mechanical work and/or equipment described above appear to have been Installed in compliance with state, local and national electric code requirements. Insp ed, y: )Y(7kc ~ ovv`n~~ . Pradeep Mohanraj Engineer SOLAR WIND GEOTHERMAL ENERGY AUDITS DESIGN I ENGINEERING I INTEGRATION I PROJECT MANAGEMENT FIELD NMORT DATE COMMENTS W ro FOUNDATION (1ST) ~ FOUNDATION (2ND) ~ W O R ROUGH FRAMING & y PLUMBING M C INSULATION PER N. Y. STATE ENERGY CODE ' y y C FINAL { ADDITIONAL COMMENTS Q U / G CPS _ o z z ? d TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following, before applying? TOWN HALL Board of Health SOUTHOLD, NY 11971 4 sets of Building Plans_ TEL: (631) 765-1802 Planning Board approval FAX: (631) 765-9502 Survey V Sou tholdTown.NorthFork.net PERMIT NO. 751 Check # Pmoo_ Septic Form N.Y.S.D.E.C. Trustees Flood Permit Examined , 20/2, Storm-Water Assessment Form Contact: ed/1 Approved, 20/ NfaHU: gym'Va. Q(,a115 Disapproved a/c / LQ;lI/ell? Cnff `5T./(,. Phone: 03 -17 Expiration, 20_/,~( Building Inspector APPLICATION FOR BUILDING PERMIT Date 9 20 Jot INSTRUCTIONS a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans, accurate plot plan to scale. Fee according to schedule. b. Plot plan showing location of lot and of buildings on premises, relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application, the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e. No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim, the Building Inspector may authorize, in writing, the extension of the permit for an addition six months. Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County, New York, and other applicable Laws, Ordinances or Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances, building code, housing code, and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. a ea n e7rt'-l (Signature of applicant or mime, me, if a corporation) 7470 ~tVnd Aik-, {t6bxr= N~ 119Sd (Mailing address of applicant) State whether applicant is owner, lessee, agent, architect, enginee C general contractor; lectrician, plumber or builder >4a~+ Name of owner of premises 1~(q (As on the tax roll or latest deed) If appl' n~is oration, signature of duly authorized odic r 17 - .gi~7t S vttc~? nd title of corporate o icer) Buil ers License No. r'IIQQI(~ y~Jg7 Plumbers License No. Electricians License No. 4-7&6-7 09C Other Trade's License No. 9.A 1. Location of land on hich proposed work will be done: 1305 Ngvi'ga) Ave, A)W06L House Number ' Street Hamlet County Tax Map No. 1000 Section ~b~j _ Block Lot LfaS per{ Subdivision Filed Map No. Lot 2. State existing use and occupancy of prerpise ~ nd intended use and occupancy of proposed construction: a. Existing use and occupancy 2 ~jl Pty b. Intended use and occupancy &WenCe ~20)y W J h adlk- A eXIa? N arr(R y 3. Nature of work (check which applicable): New Building Addition Alteration tri Repair Removal Demolition Other Work 4. Estimated Cost I goww Fee (Description) (To be paid on tiling this application) 5. If dwelling, number of dwelling units t Number of dwelling units on each floor If garage, number of cars rA indr 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. O/A 7. Dimensions of existing structures, if any: Front Rear Depth Height Number of Stories Dimensions of same structure with alterations or additions: Front Rear Depth Height Number of Stories 8. Dimensions of entire new construction: Front Rear Depth Height Number of Stories 9. Size of lot: Front Rear Depth 10. Date of Purchase Name of Former Owner 11. Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law, ordinance or regulation? YES NO ? I~/A 13. Will lot be re-graded? YES NO ? Will excess fill be removed from premises? YES NO *Qvt 14. Names of Owner of premises GLfV ( 0O aIOJPFX Address )Z06ha AVe, 11% Phone No. Name of Architect Address Phone No Name of Contractor 64.1 em 6A-dV rJ LLC Address 0 Phone No. W/ 779- 1Uck Ai / i19v~2 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO * IF YES, SOUTHOLD TOWN TRUSTEES & D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO ? * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey, to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. 18. Are there any covenants and restrictions with respect to this property? * YES NO I/ * IF YES, PROVIDE A COPY. STATE OF NEW YORK) SS: COUNTY OF ~t 6 ( ~e M being duly sworn, deposes and says that (s)he is the applicant (Name of individual signing contract) above named, (S)FIe is the nt/ C /l `fi't"'F4 c' t (Contractor, Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be performed in the manner set forth in the application filed therewith. Sworn to before me [ O~ day of~ 20L-:?~ Notary Public BA'. RA B. TANDY Signature of Applicant Notary Public, State Of New York No. 01TA6086001 e Qualified In Suffolk County- Commission Expires 01/13/20 J e7O hO~~ofSWly~ ~ .~~~pp,EY ~lo(OM %a- i Town Hall Annex 4 4 Telephone (631) 7_65-1802 54375 Main Road ~~rr {63l) 7~6~..yy5pp~~ P.O. Boat 1179 NG roper.richert(0Rt01M1.soUttl0%.ny us Southold, NY 11971-0959 "W~ilr BUILDING DEPARTMENT TOWN OF SOUTHOLD APPLICATION FOR ELECTRICAL INSPECTION REQUESTED BY: 66114 (1 6 Date: 9 Company Name: ~h ya g Name: ~k A1cfeui License No.: Address: 1 76 a cK 9 Phone No.: 41 JOBSITE INFORMATION: (*Indicates required information) *Name: ~e~N ~00~ In *Address: lD~ piaylle.,) A7~~ /{>'i/i/~K{~ (195 *Cross Street: *Phone No.: 70~~-a9~ 9i~6 Permit No.: 3 5 ro Tax Map District: 1000 Section: fo(a Block: Lot: a p, *BRIEF DESCRIPTION OF WORK (Please Print Gleamy) ~Ib( PV AT(dV - 6xf Mooofi !3~i5+e (Please Circle All That Apply) *Is job ready for inspection: Y / NO Rough In Final *Do you need a Temp Certificate: ES NO Temp Information (If needed) *Service Size: 1 Phase 3Phase 100 150 200 300 350 400 Other *New Service: Re-connect Underground Number of Meters Change of Service Overhead Additional Information: PAYMENT DUE WITH APPLICATION 112-Request for Inspection Form Of SO~ryOlo Town Hall Annex y yy Telephone (631) 765-1802 54375 Main Road T T Fax (631) 765-9502 P.O. Box 1179 G Q Southold, NY 11971-0959 WWI BUILDING DEPARTMENT TOWN OF SOUTHOLD November 8, 2013 Gerard Goehringer PO Box 812 Mattituck, NY 11952 Re: 1305 Bayview Ave, Mattituck TO WHOM IT MAY CONCERN: The Following Items (if Checked) Are Needed To Complete Your Certificate of Occupancy: "Note/: Letter required from an architect or engineer to certify the fastening of the panels to the roof ? Application for Certificate of Occupancy. (Enclosed) Electrical Underwriters Certificate. (Contact your electrician) A fee of $50.00. Final Health Department Approval. Plumbers Solder Certificate. (All permits involving plumbing after 411/84) Trustees Certificate of Compliance. (Town Trustees # 765-1892) Final Planning Board Approval. (Planning # 765-1938) Final Fire Inspection from Fire Marshall. Final Landmark Preservation approval. Final inspection by Building Dept BUILDING PERMIT: 37561 - Solar Panels i rF(inUciud,~nq OF PROPERTY 5840.0o 5"E N 40.00' ~ E p/o lots #IGI-21) P/O SHORE ,°~GRES o21 , UARY 3, IgI4 FILE No. 41 69 3+1~ i s SITUATE: MATTITUGK J' TOWN: SOUTHOLD 0 I SUFFOLK 'COUNTY, NY Tp, e X07 SURVEYED OG-19-01 ~s~' ° P/O AMENDED II-14-01, LOT I 12-13-01 ° 22 o shed SGT# IOOD-106-6-16.2 P/OO ° v y 4~ CERTIFIED TO: LOT \ i 9 area 21 osve-+ 6ERARD P. 60EHRIN&ER Qrrve.+ay P~k'n I/ / I BARBARA J. 60EHRIN6ER I I S ~ ~ timber uX'b I . A o°\ ~ ~ ~ I P/O N tel. f - Y . qe 4 b P/O LOT L i 19 ~19a.+ RSt O22 T I 2fV~ j o y r"", ti ^q^y Q. i ~N ~ J~~ Wa 4 Z Q ~ ;c o~~ I r i ti \ti L i or O ~00 ' m ( I. riell A~ of LL, ~P A+ L~ _ F U G. ~.p vwcn<.a arc:a~>.amwbe.w. ~ \ 2Q6' 32 p,JEt"E"( * w,:w•. ranw~~a~o..... eoae f~0 3 A W P s A ~P,~ ti +N'~,'..,.~?' ` bw...w w,ww NOTES: Qjq q'6 ~00 LA O wap.y as u~una ¦ MONUMENT AREAS, JOHN C. EHLE S LAND SURVEYOR AREA : 50,1-18 sF OR 1.15 ACRES 6 EAST MAIN STREET N.Y.S. LIC. N0.50202 RIVERHEAD, N.Y. 11901 GRAPHIC, 56ALE 1'. 50' 369-8288 Fax 369-8287 REF.-\\Hp server\d\PR0S\01-274b.pro GENERAL NOTES Roof Section A Subject roof has no more than one layer mean roof height 25 ft Panels mounted flush to roof no higher than 6 inches above surface. pitch 7 in/12 t CONTRACTOR$HAU. CHECK AND VERIFY ALL CONDNIONS AT THE 11. THE OWNER SHALL SELEC r ALL FINISH MATERIALS AND COLORS. roof rafter 2x6 SITE PRIOR TO STARTING TO WORK AND SHALL FAMILIARRE 12.T HESE DRAWINGS AS INSTRUMENTS OF SERVICE ARE AND SHALL HIMSELF WITH THE INTENT OF THESE PLANS AND MAKE WORK REMAIN THE PROPERTY OF THE ENGINEER WHETHER THE PROJECT rafter spacing 16 in OC AGREE WITH SAME. FOR WHICH THEY ARE MADE IS EXECUTED OR NOT. THEY ARE 2. CONTRACTOR OR OWNER SHALL OBTAIN ALLRE-OWREDAPPROVAL$. NOT TO BE USED ON ANY OTHER PROJECTS OR EXTENSIONS TO Reflected roof rafter span 10.4 ft PERMITS. CERTIFICATES OF OCCUPANCY. INSPECTION THIS PROJECT EXCEPT BY AGREEMENT IN WRITING AND WITH Table R802.5.1 (1) max allowable 13.3 ft APPROVALS, ETC.. FOR WORK PERFORMED FROM AGENCIES HAVING APPROPRIATE COMPENSATION TO THE ENGINEER. JURISDICTION THEREOF. IF REOUIREO. 13. CONTJALTORSNALLPROTECT,PATCHANDROARNLEWTWGY AOJACEHTTOH6'M3RK collar tie 2X4 3. ALL WORK SHALL CONFORM TO CONSTRUCTION CODE AND OR)AMAGED AS RESULT OF HIS YARK ALL RULES AND REGULATIONS OF THE RESPONSIBLE JURISTICTION. 1N 7EA6CpITRACTpRSSHALL FRLNDE AI'. EDVPLffNi, TOMS. FEN'..ES.TRAYBPDRTAl1pH5, collar tie spacing 48 in OC 4. ALL METHODCONTRACTTOROR. . TO BE CAREFULLY W=GUVmS.ETC.ASREOUREDFORTHEPMPERE%ECUMMOFiRIiWGPoL SUPERVISED B ByY THE THE CONTRA MID WMNN NNSURNKE LE CONiRAC'C~Y$DABAIiY, tWNIX Wd5 5. THE COURSE CONSTRUCTION A CONDITION EXISTS 15. CONTRACTORTOEFTE^TIF IN WHI C WITH SHAH THAT AS INDICATED ON THESE PLANS, CpWENBAipN, CCJA?LEIEG OPEA/`TgN, LTG J1)E9WNRTNE?I.PPOSES OF TYG PROJECT AM THECONHESHALLSTOP WORK ANDIRNOTIFY EA THE ENGINEER FURA?Ji PROCFCF SANE PRpRTOIXMBIENLINE WITF?nIXtN. CONTINUE N, WITH THHEFAILTO FOLLOW THIS PROCEDURE AND WITH CONSTRUCTOR! RACTOR MERESPO11S13LEFMi LAWTNAM)yiEiYCti NTiM 511E OIIPoNG TNEWORKRK,HE SHALL ASSUME ALL RESPONSIBILITY AND TI T,E CONSiRUCTKXN PHASE m COMPLY KITH THE LAID REGUTATIOHS REDUREABNi$fIFiHE LABILIttiNEREFROM1t COCWATKXNL SAFET'ANDNEMTNAMttA3TRl,LKNL TIK SNAIL NMUiIE B'TARE NOT LPATEOiO: 12 6. ALL STRUCTURAL STEEL SHALL BE A-36 AND SHALL BE PRDADNG Fot N1EMATE AND PROPER SRACNG. SAFETY PAUMSNO SECNE FOOTWGA F,N ALL FABRICATED AND INSTALLED AS PER LATEST A.IS.C. Ta3PRARY SCAFFMDNIG•STAIRS. ETC, AS WELL AS PERWENrCONSTRUCTION. SPECIFICATIONS, 11. FIGURED DIMENSIONS SHALL GOVERN. DO NOT SCALE DRAWINGS. WHERE DMEJSWNSARE -7. ALL DRYWALL SHALL BE U.S.G. NATIONAL GYPSUM CO. S/ S' ESTABLISHED BY E=N/G COFSfTIONS EACH CONTRACTOR SML, EM" EXISTING CONDITIONS \SEE OET_'I THICK UNLESS OTHERWISE NOTED. PRIOR TO ORDFANGLIRtRIAUMOCOMMEBIGWItHWOFIK. V~ e. ALL ELECTRICAL. WORK$RALLBE WELI ITH NEOF PRE IJNDERWRRERS D AND IN 1B.CONTRACTORSHALL000RLIRATEALL PHASES OR WORKWITH THE REOLARED PARTIES. ALL CODES b R REGUEGU E LATIONSONS. . ACCORDANCE WITH NE.C.A WS PHASES OF ADJACENT FACILITIES OPERATIONS SHALL BE MAINTAINED WRING CGiNSTRUCTION. 1 CODES 9. ANY DEVIATION FROM THESE PLANS WITHWTTHE WRITTEN CONTRACTOR SHALL KEEP SITE FREE OF CONSTRUCTION DEBRIS AND KEEP SITE FULLY ACCESSIBLE CONSENT OF THE ENGINEER WILL NEGATE THE ENGINEERS TO THE PUBLK WRING HOURS OF YPERATICN. CERTIFICATION OF THESE PLANS. 19. CONTRACTOR TO REMOVE ALL DEBRIS CREATED BY THIS WORK FROM THE SITE AND DISPOSE OF SEE SET. 1 Roof Cross Section 10. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR CUTTING. IN A LEGAL MANNER ONA WEEKLY BASIS OR SOONER IF CONDITIONS WARRANT. T FIT ING OR PATCHING REQUIRED TO COMPLETE THE WORK OR TO N. AT THE COMPLETION OF WORK, THE Sn E IS TO BE CLEARED OF ALL DEBRIS AM EXCESS MAKE IT'S PARTS FIT TOGETHER PROPERLY. MATeOLS. THE FACUW STO M LE,7 aR00M CLEAN AW WORK IS TO SE COMPLETED TO rJ,T,S THE TOTAL SATISFACTION OF THE D:YNER PRIOR TO RELEASE OF FINAL PAYMENT. APPROVED AS NOTED d.. CONDUIT DAfi@` /0 ! B,plill 37~5~ r FROM ARRAY _ Fio' 13Y tIOTIFy BiNLvl,ds 7E kRTME>JT AT INVERTER INVERTER 7[J5 1202 ANI 4 FM FOR I HE cOLLO,'iNC WOO TKAS 1 FOUNDN ION dG kEQUIRED :i DO FORPOUREL' JNCRETE I,G.;,_ fw.; METER WIRING GUTTER 2. ROUGH - FRAM a,; °LUMBiNG, w DISCONNECT , r STRAPPING ELECTRICAL & CAULKING s SERVICE R AC Ac I oe MUST BE COMOfJTc FOR C 0- ~a cm pALL CONSTRUCTIC". SHALL MEET THE ` ERTFI ,%91REMENTS~FTHECODESOFNEW Y J 11 I~RSTATE. NOT RESPONSIBLE FOR NN TYPICAL RISER DIAGRAM ! f DESIGN OR CONSTRUCTION ERRORS. .x S: 'A IT End Ci@mp i a L-tDD+ i RISER DIAGRAM SHOWN FOR REFERENCE ELECTRICAL INSPECTION REC kqt Revisian5 saGt6i0Uni Rog To my best belief and information the work in this document is accurate, con orms wl I t Redsian 4 .'SWgGwliRaa k governing codes applicable at the time of submission, conforms with reasonable standards Revision a TYPICAL CONNECTION DETAIL 1 ALL ROOF PENETRATIONS ARE TO BE SEALED of practice, with the view to the safeguarding of life, health, property and public welfare, Re„,ion 2 PV PANEL WITH SIKAFLEX OR EQUIVALENT SEALANT Section: 106 and is the responsibility of the licensee. ReviW.1 Block: 6 P.MfAf° P-CIFI O EN INEERIN P as per ASCE7, Method 1: A (fig s-z) 1.35 I (table 6-1) 1 Pnet =A Kzt /Pnet30 (eg6-z) Kt (secs.6.7) 1 Pne130(fig 6-3) -25.9 Lot: 20.4 OF NEw ft- 700 Lakeland Ave, Suite 26, 130Aewiin, NY 11716 CLIMACTIC AND Ground Wind Speed, Live load, Maximim QV 9\A PAC/YO Tel: 631-988-0000 Fax: 631-382-8236 Emait: eLnyineer@ acifieoe"Ineeri ng.com F 7 9 point pullout fastener O GEOGRAPHIC DESIGN Category Snow Load, 3 sec gust, pnet30 per Fastener type O CRITERIA Pg mph ASCE 7, psf load, lb spacing an °"9 2' * berry Goehringer Roof Section A C 20 120 35 377 5/16" dia screw, 3-1/2" length ,48 ~ , /Z w 1305 Dayview Ave, Mattituck, NY 12952 S-001.00 PROPOSED SOLAR ENERGY fNSTALLATION sFp 066192 4ENERAL NOTES, ROOF SECTION, DATA, DETAILS AND SPECS Rai nee, sw.: NYO 443136 09/25/12 AS NOTED 1 of 2 PROPOSED SOLAR INSTALLATION FLUSH MOUNTED i 18" CLEAR PATH i i A A SOLAR SOLAR SOLAR SOLAR SOLAR SOLAR SOLAR SOLAR SOLAR ' CS6P-245 CS6P-245- CS6P 245 CS6P-245 CS6P-245- CS6P-245- CS6P-245 CS6P-245- CS6P-245 j t O 9= !AIM66 to S OLAR OLAR SOLAR SR SOLAR SOLAR - SOLAR SOLAR SOCS6P245 P-245 CS6P-245 CS6P-245 CS6P-245 CS6P-245 C86P-245 CS6P-245 CS6P-245 CS6P-245 CS6P-245 EM -1 r i DISCONNECT LOCATED 40_911 IN FRONT OF HOUSE ;Ole ON EAST SIDE ROOF LAYOUT O ENGINEERING PC OrLzxrn PV Panel ~pF NEW Y 700 Lakeland Ave, Suite 26, Bohemia, NY 11716 A PAC/ RCO,9~ Tel: 631-988-0000 Fax: 631-382-8236 Email: en ineer@ acificoengineering.com QN Canadian Solar CO PANEL: CS6P-245 e c Gerry Goehringer QTY: 20 w 1305 13ayview Ave, Mattituck, NY 11952 LENGTH: 64.5 In m ~a^~/' C? PROPOSED SOLAR ENER4Y INSTALLATION S -002.00 I have reviewed the rootirg structure at the subject address. The structure can support the additional weigh of the roof mounted system. The units are to be installed in accordance with the manufacturers installation WIDTH: 38.7 in `r(o 066162 v GENERAL NOTES, ROOF SECTION, DATA, DETAILS AND SPECS instructions. I have determined that the installation will meet the requirements of the 2010 NYS Building Rai p, o ineer ow: sum Code, and ASCE7-05 when installed in accordance with the manufacturers instructions. WATTS: 4900 NY 0 ,vV 44306 04/25/12 AS NOTED 2 OF 2