Loading...
HomeMy WebLinkAbout38496-Z Town of Southold Annex 12/5/2013 yIfFB3 P.O. Box 1179 46 54375 Main Road Southold, New York 11971 CERTIFICATE OF OCCUPANCY No: 36637 Date: 12/5/2013 THIS CERTIFIES that the building AS BUILT ALTERATION Location of Property: 1775 Pt Pleasant Rd, Mattituck, SCTM 473889 Sec/Block/Lot: 114.-1-6 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this officed dated 11/4/2013 pursuant to which Building Permit No. 38496 dated 11/12/2013 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: "As built" alterations to an existing one family dwelling as applied for The certificate is issued to Erwin, Diane M. (OWNER) of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. PLUMBERS CERTIFICATION DATED t}I rize Signature TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE m SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit 38496 Date: 11/12/2013 Permission is hereby granted to: Erwin, Diane c/o DeCoste 65 E India Row Boston, MA 02110 To: "As built" alterations to an existing single family dwelling as applied for. Additional certifications may be required prior to issuance of a CO. At premises located at: 1775 Pt Pleasant Rd, Mattituck SCTM # 473889 Sec/Block/Lot # 114.-1-6 Pursuant to application dated 11/4/2013 and approved by the Building Inspector. To expire on 5/14/2015. Fees: AS BUILT - SINGLE FAMILY ADDITION/ALTERATION $1,549.60 CO - ADDITION TO DWELLING $50.00 Uotal: $1,599.60 Building - Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings, property lines, streets, and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal (S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead. 5. Commercial building, industrial building, multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings (prior to April 9, 1957) non-conforming uses, or buildings and "pre-existing" land uses: 1. Accurate survey of property showing all property lines, streets, building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied, the Building Inspector shall state the reasons therefor in writing to the applicant. 4z-s C. Fees 1. Certificate 40ccupancy - New dwelling $50.00, Additions to dwelling $50.00, Alterations to dwelling $50.00, Swimming pool $50.00, Accessory building $50.00, Additions to accessory building $50.00, Businesses $50.00. 2. Certificate of Occupancy on Pre-existing Building - $100.00 3. Copy of Certificate of Occupancy - $.25 4. Updated Certificate of Occupancy - $50.00 5. Temporary Certificate of Occupancy - Residential $15.00, Commercial $15.00 Date. 711513 New Construction: Old or Pre-existing Building: (check one) Location of Property: 1775 1~b it-+T PL.jaNtot~ PA m&-ntwCLe- t- 1I I5D House No. Street Hamlet Owner or Owners of Property: Suffolk County Tax Map No 1000, Section Block Lot 15 lie Subdivision Filed Map. Lot: Permit No. Date of Permit. Applicant Health Dept. Approval: Underwriters Approval: Planning Board Approval: Request for: Temporary Certificate Final Certificate: f/ (check one) Fee Submitted: $ Applicant Signature CONSENT TO INSPECTION v I a 0 Q u e OCG e G1e 1,J I "1 the undersigned, do(es) hereby state: Owner(s) Name(s) That the undersigned (is) (are) the owner(s) of the premises in the Town of Southold, located at 19 qS PDl /1T PL8A5A-/-17 Qcxe_pL ~(11q-RC ~,c 1<< ~~gS~ which is shown and designated on the Suffolk County Tax Map as District 1000, Section , Block , Lot (o. That the undersigned (has) (have) filed, or cause to be filed, an application in the Southold Town Building Inspector's Office for the following: J...EsC~LiZ.~ 'PPe2-ci~~ ~i'w~iSkkF~ r,1D ~oeo That the undersigned do(es) hereby give consent to the Building Inspectors of the Town of Southold to enter upon the above described property, including any and all buildings located thereon, to conduct such inspections as they may deem necessary with respect to the aforesaid application, including inspections to determine that said premises comply with all of the laws, ordinances, rules and regulations of the Town of Southold. The undersigned, in consenting to such inspections, do(es) so with the knowledge and understanding that any information obtained in the conduct of such inspections may be used in subsequent prosecutions for violations of the laws, ordinances, rules or regulations of the Town of Southold. Dated: 71)5- 3 ~1 [mot (Y~l~ (XG L Ui L h (Signature) (Print Name) (Signature) (Print Name) Electrical Inspection Certificate Issue Date Electrical Inspection Service, Inc. Application 7/11/2005 375 Dunton Avenue 98292C East Patchogue, New York 11772 (631)286.6642 Issued To: Ms. Diana DeCoste Street: 1775 Point Pleasent Village: Southold Zip: 11952 Town: Southold Section: Block: Lot: Contractor: Shore Power Electric Contracting Lic. # 31697-ME Was examined and found to be in compliance with the National Electrical Code. Commercial i NV Defects Pool Xi list Floor XI Indoor Basement 7 Hot Tub X. Residential . Det. Garage Attic 2nd Floor A I Outdoor Addition i Survey Switches Receptacles Fixtures GFI Heaters A7C Fans 4 4 7 3 Dishwasher Washer/Amps DryerlAmps Oven Range/Amps Microwaves 1/20 2/30 1 40 1/20 Furnace Oll Gas Circulators Smoke Detector Bell Transformer Meter Amps Phase UG/OH Jacuzzi Television CO Detector 1 200 1 x; Bldg. Permit: Other Equipment 1 200amp panel with main breaker Hugo S. S di President Rough Inspection: 0412812005 Inspector: John McMahon III Final Inspection : 07/072005 Inspector: John Mc Mahon III This certificate must not be altered in arty manner. Inspectors may be identified by their credentials. ~j / I ~c9 C /~1 C~t9'> c J gl L AOF SOUTyo* UNfr` F TOWN OF SO ING DEPT. 765-1802 ILD IN ON [ ] FOUNDATION 1ST [ ] ROUG LBG. [ ] FOUNDATION 2ND [ ] I LATION [ ] FRAMING / STRAPPING FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) REMARKS: lti ka V--t- r E-L C E dti e v o L'L r,"e -trv~ f 'ter l 2w e l 1 ~t DATE /)-JC/~/~ INSPECTOR A'j NORTH SHORE ARCHITECTURE & INTERIORS Norman Nemec AIA 41 Onderdonk Ave. Manhasset, N.Y. 11030 (516) 627-5664 (515) 220-2784 (cell) Chief Building Inspector Michael J. Verity Southold Building Department 54375 Main Road Southold, NY 11971 Date: 8-4-13 Re: Building Permit Application to maintain a finished second floor located at 1775 Point Pleasant Road, Mattituck NY 11952 Tax Map 1000-114-01-006 Dear Inspector Verity: This letter shall serve to certify that the enclosed plans and specifications outlining the finished second floor which was finished with gypsum wall board over ten years ago is in conformance with the Building Code in effect at the time. The original house and second floor was constructed to my knowledge over 100 years ago. The second floor has prior certificates of completion for a bedroom and a bathroom. This application is to legalize the rest of the second floor insulated and finished without a Building Permit. All roof and wall framing cavities have been insulated to the full depth of cavity with insulation exceeding R 3.0 / inch. The plans comply with the provisions of the NYSRC Appendix J104 Alteration Level 2 which requires that the Energy Construction Code conformance can be achieved by NYSRC N1101.3.1. N1101.3.1 Exception 3 permits compliance without the requirement of Rescheck Computations provided that all wall and roof framing cavities of an existing structure (built prior to the 2000 Code) are insulated to the full depth of all framing cavities with an insulation such as fiberglass batts having an R Value of 3 or more per inch. This letter shall certify that I inspected the existing finished second floor of the subject structure and it is in conformance with the NYS Uniform Building and Fire Prevention Code. Sincerely, XSZ ER ED A ~0 MAN h,FC'SiTi^ n a ~TF 15987 Norman Nemec AIA °F N yO~` FIELDR~~NMMIPORT DATE COMVMINTS 4-1 FOUNDATION (IST) FOUNDATION (2ND) 04 r, ROUGH FRAMING & PLUMING INSULATION PER N. Y. STATE ENERGY CODE MAL ADDITIONAL COMMNTS qtx) AP 7 ~7 TOWN OF SOUTHOLD _ BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following, before applying? TOWN HALL Board of Health SOUTHOLD, NY 11971 4 sets of Building Plans TEL: (631) 765-1802 Planning Board approval FAX: (631) 765-9502 Survey SoutholdTown.NorthFork.net PERMIT NG. ( L Check Septic Form N.Y.S.D.E.C. Trustees C.O. Application Flood Permit Examined 20~ Single & Separate Storm-Water Assessment Form Contact: Approved 1 ( 20T Mail to: Disapproved a/c Phone: L 3)--V0V Z,5-0'7 Expiration , 20 D~ ng Ins ector _ ~ IPPLICATION FOR B ILDING PERMIT Date 1115~13 20 INSTRUCTIONS to,;n, t,r Q n! ~ r'ini a Thai appheatrarr npletely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans, accurate plot plan to scale. Fee according to schedule, b. Plot plan showing location of lot and of buildings on premises, relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application, the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e. No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 month?; from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim, the Building Inspector may authorize, in writing, the extension of the permit for an addition six months. Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County, New York, and other applicable Laws, Ordinances or Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances, building code, housing code, and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. (Signature of applicant or name, if a corporation) (Mailing address of applicant) State whether applicant is owner, lessee, agent architect, engineer, general contractor, electrician, plumber or builder Name of owner of premises "p~p.._5~ t .5-t~ w•~~ (As on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer (Name and title of corporate officer) Builders License No. Plumbers License No. Electricians License No. Other Trade's License No. 1. Location of land on which proposed work will be done: 1775 TUCL tJ 119~~ House Number Street Hamlet County Tax Map No. 1000 Section y Block l Lot 15- ~/p Subdivision Filed Map N,o,--., Lot 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy b. Intended use and occupancy ?2~t»~ ~Li , ~L-r 3. Nature of work (check which applicable): New Building Addition Alteration Repair Removal Demolition Other Work (Description) 4. Estimated Cost Fee (To be paid on filing this application) 5. If dwelling, number of dwelling units Number of dwelling units on each floor If garage, number of cars 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of existing structures, if any: Front Rear Depth Height Number of Stories Dimensions of same structure with alterations or additions: Front Rear Depth Height Number of Stories 8. Dimensions of entire new construction: Front Rear Height Number of Stories 9. Size of lot: Front Rear Depth 10. Date of Purchase Name of Former Owner 11. Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law, ordinance or regulation? YES NO ? 13. Will lot be re-graded? YES NO t/ Will excess fill be removed from premises? YES NO 14. Names of Owner of premises bjA)zi ' occiprtG Address 1771 Poi I a,} , Phone No.[51b) 578 -2-141o Name of Architect u pp ua~'~, NEM FE C- Address 41 &1IM one No l ~Ib) G 2 7-SLGQ Name of Contractor Address ~ - Ylionnee No. 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO * IF YES, SOUTHOLD TOWN TRUSTEES & D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey, to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. 18. Are there any covenants and restrictions with respect to this property? * YES NO * IF YES, PROVIDE A COPY. STATE OF NEW YORK) SS: COUNTY OF ) being duly sworn, deposes and says that (s)he is the applicant (Name of in ividua s~ ing contract) above named, CONNIE D. BUNCH Notary Public, State of New York (S)Heisthe No.OIBU6185050 (Contractor, Agent, Corporate Officer, etc.) oualiffed in Suffolk County Commission Expires April 14, 2-C) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be performed in the manner set forth in the application filed therewith. Sworn to before me this day of D c4* _ 20a Notary Public Signa re of Applicant QJ i.nr &tPUrc' ~ v' TMB C W:l• ~ ' •JW6 BSW' OUN[ 1911 wn~ ~n [v JS'O~ i~ rr~ ~F•_~ J ~ _ ~ fQINO DOM 4 - J E RESIDENCE y r ~ r ~aw~ 5T0.W ~ 11Y9ER eU NM' ~IfWI JBNEx'x! 541E SIE°5 ~ 1 SfWI g .wo rwaE .s~ ~ xeslocxcE cw,c " 8 P J' qao a " scrs 1 kJ M c bs_ ~ Ah ` I~ 14Vr, ihuxfn_ ^rJx 4~ ~Y° Id EL-fD 8E21 A')3, 4wr, 1' ~i, 14r E3'-f 1. ?591 30-y cTSaool. G„..u- r, 0WR wl, J yw 9px r;l;ur b J- ~~WillplCl'. 1+71957 _ 1'ks' ~ ~5 ~0' tpLI tfl. iln n4 P1F 3».50, `Aa FM/ I2C 31 DATE FILED mAY 1916 a g' ~S SURVEYED: 19 DECEMBER 2001 TNM 1006-Ila_O t-006 sUR.cY or SCALE I'= 40'', h LOTS 15 & 16 y m AREA - 67,870.94 c.F. MAP OF "POINT PLEASANT" L55ERACRES MATTITUCK BAY DEVELOPEMENT SITUATE SURVEYED BY STANLEY J. ISAKSEN, JR. ! X7 01OVx` P.O. BOX 294 MATTITUCK, TOWN OF SOUTHOLD NEW SUFFOLK. NY. 11956 cuDIAN E D 1D. 631- 734 583-`, U OECOSTI SUFFOLK COUNTY, N. Y. FJDElltt 8 FlO NATIONAL iRL INS. CO i9 SURVEYED FOP: DIANE DECOSTE LIG No_D LA JIL RVE Z F~: ~ q NYS Lrc No. 49273 F1~E OCCUPANCY OR Andersen CW13 (5) Andersen CW15 Egress Compliant Andersen CW13 USE IS UNLAWFUL Casement Window U=.31 Casement Windows U =.31 Casement Window U=.31 ELOCTIFrCAL WITHOUT CERTIFICATE Legend INIAPMOT'ON A44ul"m%F OCCUPANCY 26_51„ 2,_76,y .."p i v O O / I ® GO fmoke and CO Alarm 120v hardwired w/ batteries and Interconnected If Roof 9 120 v 20 amp duplex wall outlet cl) g some except w/ GPCI 42" above floor APPROVED AS NOTED O O $ ,77 \ i27y~-6T I O Recessed downlight DATE: /1 1Z 60 B p 90 ~$ygg Mattituck Creek FE44l U9 _ BY. - v \ , - - v Iyp. 44") ED furface mounted clg. light fixture NOTIFY BUILDING \ Typ. 44"x44" OperableJkylight, Lamin Double pdne Glass i% _ - - - - - - _ _ TG 4PM FORTHAT i FOLLOWING INSPECTIONS: f urface mounted wall light fixture I. FOUNDATION - TWO REQUIRED r FOR POURED CONCRETE c_-J/ / t / / A bedroom Wall switch 42" off 3, NSUL TIONRFlMING G PLUMBING 4. FINAL - CONSTRUCTION MUST bd~k Chimney \ HVAG Duct w/ Diffusers M" Aff BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR Gelling/Roof Gelling/Roof Wes, typ. DESIGN OR CONSTRUCTION ERRORS. D endows \ 1 _bedroom / - Db'Wi, eInsul. flYJRG Mln, Room Area =705f (1x10) R504.~ \ Gofcon file 26"Wid \ ex42"High Existing finished 2nd floor heated sufficiently to \ \ Gg Ht T-6" \ maintain 78 degrees fahrenheit COP? PLY V<TrH ALL CODES OF year round at a point 3 ft above floor, NEW YORK ST',' E & TOWN CODES 1 NJ IIA& 1' \ \ \ 2 feet from all walls in all habitable rooms. AS REQUIRED , \ north 1 \ 1 Existing fin Existing finished 2nd floor, w/ 2x8 16" o/ Roo Rafters e r (y~ ~ u dv.ct and full ll del and full depth of framing cavity R-19 FG~Insul.i A \ - J'team Rod. LLW~ LLof r %IVI Ceiling is fi Ceiling is finished with z' painted gyp bd K \ \ 0 PLUMBER CERTIFICATJON . EN I o COERTIFICATEOFOCCUPANCY \ 1 - All exterior All exterior 2x416" Walls have A > SOLDER USED IN WATER 1 been insula --s-Z~- _ _ been insulated w/ R13 FG Insul. SUPPLY SYSTEM CANNOT DH Windows to full dept: to full depth of framing ca~ity EXCEED 2110 OF I% LEAD. \ Dble Pane Insul. Living Room - - - - - - - - - - VAC Room 1st floor Deck below 28" Wide x 42" High Ell A porage -77 7-7 PLUMBING ALL PLUMBING WASTE 1 TESTING BEFORE COVERING 1 / porage \ 1 \ rt rage Room . 111711z ~ batf(aom \ , , - /(~fG on file Existing finished 2nid floor heated sufficiently to 'S'- - - - - _ - \ maintain 78 degrees fahrenheit 1 - / r \ year round at a point 3 ft above floor, Jtorage Room / 2 feet from all walls in all habitable rooms. 1 ~ / - \ N riPa \ 1 D 16R @;7.5" ea \ \ Roof and 9.5" treads Roof / ® \ \ Existing finished 2nd floor, w/ 2x8 16" o/c Roof Rafters rs 1 and full deptb of framing cavity R-19 FG Insul. f Roof CO " \ Ceiling is finished with i' painted gyp bd. DH Windows \ 1 / - - f / Dble Pane It sul. A i / - 28" Wide x 42" High Roof \ 1 / Or17 - \ 1 y f"... Energy Code Conformance: I' Tax Map 1000-114-01-006 a00; s` Total Area of Finished Second Floor Point Pleasant Road (Home Pike- Private) Requiring Legalization = 1,063 SF S~ Existing finished 2nd floor hented sufficiently to July 12th, 2013 Issued for Building Department Approval maintain 78 degrees Fahrenheit Project Scope: Legalize Partial Finished Second Floor year round at a point 3 ft above floor, f ite Plan 1/32" - I-O'I (econd floor Plan 1/4" =1r-0" 2 feet from all walls in all habitable rooms. Original brick Chimney Revised B-3-13 per Bldg Dept Request Natural Light: Floor Area of Finished Room =1,061 SF Required Glazing (8303) 1,061 x.08 = 84.88 SF Existing Original Roofftructure, no structural changes. EflEO DeCoste Residence Glazing Provided = (5) 20 x 60 csmt 14101 + (2) 20x36 csmt jIUsf1 + (4) 44x44 Skylights [53sf] + (1) 28x36 skylight [7sf1 + (4) 28x32 DH windows [49sf1= 160 sf of glazing provided. 1775 Point Pleasant Road Al INVVJ RL Min. Rc Fresh Air Ventilation: Floor Area of Finished Room = 1,061 SF NVp /tY1RCMin. Room Area -70sf(Tx1(Y)R304.2 Required Fresh Air Ventilation Openings (R303) 1,061 x .04 = 42.22 SF AYJI ; Min. G AYJRC Min. Ceiling Height Required R305.1= T-0 {,I - ` Mattituck, AY 11952 s Ventilation Provided = (5) 20 x 60 csmt [20.5sf1 + (2) 20x36 csmt [5sf] + (4) 44x44 Skylights [26.5sf] Actual C.19 My Actual Clg My Provided = U-10 VIV, n " + (1) 28x36 skylight [3.59f] + (4) 28x32 DH windows [24st] = 79 sf of fresh air ventilation provided. ",rF J5987 Tax Map 1000-114-01-006 ap NEW Yo0 These plans comply with the 2010 NYS Energy Conservation Construction Code, Section 101.4.3, Exception 3- All existing roof and wall framing cavities are insulated to the full depth of framing cavity with FG insulation exceeding R 3.0/ inch. 0 Existing Bedroom with prior CofC R-19 M Full Roof Cavity Depth Insu at(on I I~ I I I NORTH SHORE ARCHITECTURE AND INTERIORS R-13 -R-13 FG Full Wall Cavity Depth Insulation 1 econd floor 41 ONDERDOAWAYENUE,MANHASSETNY 11030 516-220-2784 nsa@optonlinexel 307FOURTHSTREET, GREENPORTNY11944 Norman Nemec AM WWW.NSAAI.COM f econd Floor f ection 1/4" V -T