Loading...
HomeMy WebLinkAbout37753-ZTown of Southold Annex P.O. Box 1179 54375 Main Road Southold, New York 11971 CERTIFICATE OF OCCUPANCY 5/21/2013 No: 36246 Date: 5/21/2013 THIS CERTIFIES that the building ADDITION/ALTERATION Location of Property: 1200 PRAITY LANE CUTCHOGUE, SCTM #: 473889 Sec/Block/Lot: 109.-5-26 Subdivision: Filed Map No. Lot No. conforms substamially to the Application for Building Permit heretofore filed in this officed dated 3/1/2010 pursuant to which Building Permit No. 37753 dated 1/14/2013 was issued, and conforms to all of thc requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: BATHROOM ADDITION/ALTERATION TO AN EXISTING SINGLE FAMILY HOME AS APPLIED FOR The certificate is issued to EDWARD WANKEL & JUDITH GORDON (OWNER) of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. PLUMBERS CERTIFICATION DATED 37753 05/20/213 A~o~zed Sig/natur~ TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit #: 37753 Permission is hereby granted to: EDWARD WANKEL & JUDITH GORDON P.O. BOX 1275 CUTCHOGUE, NY 11935 Date: 1/14/2013 To: ADDITIONS & ALTERATIONS TO AN EXISTING SINGLE FAMILY DWELLING AS APPLIED FOR.REPLACES EXPIRED BP # 35362 At premises located at: 1200 PRAITY LANE CUTCHOGUE SCTM # 473889 Sec/Block/Lot # 109.-5-26 Pursuant to application dated To expire on 7/15/2014. Fees: 311/2010 and approved by the Building Inspector. PERMIT RENEWAL CO - ADDITION TO DWELLiNG Total: $75.00 $50.00 $125.00 Building Inspector FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 35362 Z Date MARCH 1, 2010 Permission is hereby granted to: EDWARD WANKEL & JUDITH GORDON PO BOX 1275 CUTCHOGUE,NY 11935 for : ADDITIONS & ALTERATIONS TO AN EXISTING SINGLE FAMILY DWELLING AS APPLIED FOR.REPLACES EXPIRED BP # 29435 at premises located at 1200 PP~AITY LA CUTCHOGUE County Tax Map No. 473889 Section 109 Block 0005 Lot No. 026 pursuant to application dated MARCH 1, 2010 and approved by the Building Inspector to expire on SEPTEMBER 1, 2011. Fee $ 150.00 Signature ORIGINAL Rev. 5/8/02 FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. (THIS BUILDING PERMIT PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 29435 Z Date MAY 28, 2003 Permission is hereby granted to: EDWARD E WANKEL PO BOX 1275 CUTCHOGUE,NY 11935 for ADDITIONS AND ALTERATIONS TO AN EXISTING SINGLE FAMILY DWELLING AS APPLIED FOR at premises located at 1200 PRAITY LA County Tax Map No. 473889 Section 109 Block pursuant to application dated MAY 27, 2003 CUTCHOGUE 0005 Lot No. 026 and approved by the Building Inspector to expire on SEPTEMBER 28, Fee $ 2004. Au ~o r~i'~-~d Signature / COPY Rev. 5/8/02 Form No. 6 TOWN OF SOUTHOLD. BUILDING DEPARTMENT TOWN HALL 765-1802 ' APPLICATION FOR CERTIFICATE OF OccUPAaNcY - ~ appli~tion must be filled in by tYPewriter or ink and submitted to the Building Department with the following: A~ For new building or new use: 1. Final surwy of property with accurate location of all buildings, property ltnes, streets, and unusual natura} or topograph/c features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal (S-9 form)2 3. Approval of electrical installation from Board 6fFire Underwriters. ' 4. Sw. om statement from Pt~mber certifying that the solder used in system contains less than 2/10 of 1% lead. 5. Commeroial building, industrial building, mtiltipte re~ideneus and similar buildings and installations, a cx~ifieate of Code ComPliaixee' from architect or engineer respomible for the bnildiag, .6. Submit planning Board Approval of completed site plan requirements. B. For existing buildings (prior toAprilg, 1957) non~conforminguses, or buildlngs and,Pre_existing, ia~duses:. 1. Accurate survey of property showing all property lines, streets, building and unusU~l naturai or topographic features. 2_ A properly c4?mpleted application and con.sent to inspect signed by the applicant. If a Certificate of Occupancy is denied, the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certifica!e of Occupancy - New dwelling $50.00, Additions to dwelling $50.00, Alterations to dwelling $50~00, Swimming pool $50.00, Accessory building $50.00, Additions to accessory building $50.00, Businesses $5000,. 2. Certificate of Occupancy on Pre-existing Building $100.00 3_ Copy of Certificate of Occupancy - $.25 . 4. Updated Certi~cate of Occupancy - $50.00 · 5. Temporary Certificate of Occupancy Residential $15.00, Commercial $15.00 New Construction: Location of Property: House No. Ownir or Owners of Property: Suffolk County T~ Map No 1000 S~tion gu~sibn Old or Pre-existing Building: Date. Street Biock (check one) Lot [tenlth Dept. Approval; ?lam'ting Board Approval: Date of Permit. Filed Map. Apphcantx Underwriters Approval: ?,equest for: Temporary Certificate :ce Sub,re,led: $ ~'C~'0~ Final Certificate: (check one) Town Hall Annex 54375 Main Road P.O. Box 1179 Southold, NY 11971-0959 BUILDING DEPARTMENT TOWN OF SOUTHOLD Telephone (631) 765-1802 Fax (631) 765-9502 ro~qer.richert~,town.southold.ny.us CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION ssued To: Edward Wankel ~,ddress: 1200 Praity Lane City:Cutchogue St: NY Zip: 11935 3uilding Permit #: 37753 Section: 1 09 Bleck: 5 Lot: 26 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE ,3ontractor: as built DBA: License No: SITE DETAILS Office Use Only Residential [~ Indoor ~ Basement ~ Service Only ~ Commedcal Outdoor 1st Flcor Pcol New Renovation 2nd Floo~ Hot Tub Addition Survey Attic Garage INVENTORY Service 3 ph Hat Water GFCI Recpt Main Panel NC Condenser Single Recpt Sub Panel NC Blower Range Recpt Transformer Appliances Dryer Recpt Disconnect Switches Twist Leck Other Equipment: 1-hydromassage tub Notes: Ceiling Fixtures [~ HID Fixtures Wall Fixtures M Smoke Datectors Recessed Fixtures [~ CO Datectors Fluorescent Fixture ~.~ Pumps Emergency Fixtures ~.~ Time Clocks Exit Fixtures ~ TVSS 1-exhaust fan, 1-combination heat lamp / exhaust fan, 1-electric wall heater Inspector Signature: Date: May 20 2013 Electrical Certificate.xls Town Hall Anezx 54375 Main Read P,O. Box 1179 $oudaotd, New York 11971-0959 T( 'Y-'q[ ~'¥OLD Telephone (631 ) '/65-1802 Fax {63 I) 765-0502 Building Permit No. ~o~X'-x~% O',~ne:': ~--_,L - '~..~..c~ _*..z.___ _ (Please print) Plumber: --x~,.--9~, ~ ~ ,~.x,~x...~- cx~- ........ (Please print) cc~,.~ 1~ that the sotder used i::~ !::5 system contains less than 2/10 of 1% day'o~ x-x-x~,.~ , 20 Notaq/Public, ~--~.._&~\X~.. Count>, ALICIA WALKER Notary Public, State of New York No. 01WA6153064 Qualified in Suffo k County Commission Expires Sept. 25, '~,~,, 765-1802 BUILDING DEPT. INSPECTION [~**~ F~JNDATION 1ST [ ] ROUGH PLBG. [ ~]' FOUNDATION 2ND [ ] INSULATION [ ] FRAMING [ ] FINAL [ ] FIREPLACE & CHIMNEY REMAR~ DATE INSPECTOR 765-1~02 BUILDING DEPT. INSPECTION FOUNDATION 1ST [ ] ROUGH PLBG. ] F~NDATION 2ND [ ] INSULATION FRAMING [ ] FINAL []FIREPLACE&CHIMNEY REMARKS: DATE /~/'///~///~ INSPECTOR ~C~~/c~''/ 765.1802 BUILDING DEPT. INSPECTION [ ] FOUNDATION 1ST [/RO/UGH PLBG. [ ] FOUNDATION 2ND [,"~] INSULATION [ ] FRAMING [ ] FINAL [ ] FIREPLACE & CHIMNEY DATE //,,~--/~/~ INSPECTOR~~ TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 I NSPECTIO ! [ ] FOUNDATION 1ST [ ] ROUG~LBG. ] FOUNDATION 2ND [ ATION [ ] FRAMING / STRAPPING [ VI' FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FiRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) DATE INSPECTOR TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION I ST [ ] FOUNDATION 2ND [ ] FRAMING/STRAPPING [ [ ] FIREPLACE & CHIMNEY [ [ ] FIRE RESISTANT CONSTRUCTION [ [ ] ELECTRICAL (ROUGH) [ ] ROUGH PLBG. [ ] INSULATION ] FINAL ] FIRE SAFETY INSPECTION ] FIRE RESISTANT PENETRATION ELECTRICAL (FINAL) REMARKS: DATE INSPECTOR~ TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL SOUTHOLD, NY 11971 TEL: (631) 765-1802 FAX: (631) 765-9502 www. northfork.net/Southold/ BUILD1NG PERMIT APPLICATION CHECKLIST Do you have or need the fol owing, before applying'? Board of Health 3 sets of Building Plans Planning Board approval Survey Check Septic Form ~' N.Y.S.D.E.C. ~- . . ,~ '/~, r-~ Trustees r:xammecl I / ~ ,20 ~ Contact: ~ Approved ~ ~ ,20 ~ Mail to: Disapproved ~ f / ~ ~ ~ 1 - ,- .,._ Date ~ ' ] INSTRUCTIONS ,20~ C> a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 3 sets of plans, accurate plot plan to scale. Fee according to schedule. b. Plot plan showing location of lot and of buildings on premises, relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be cormnenced before issuance of Building Permit. d. Upon approval of this application, the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e. No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 13 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim, the Building Inspector may authorize, in writing, the extension of the permit for an addition six months. Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County, New York, and other applicable Laws, Ordinances or Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances, building code, llaosing code, and regulations, and to admit authorized inspectors on premises and in building for necessary inspecti_ons.// (,Sig~e of applicant or name, if a corporation) (Mailing address of'applicant) ~/ State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder Name of owner of premises ,~'~,~,~ .~. g'~,6~e e~d_ (As on the taSc roll or latest deed) If applicant is a corporation, signature of duly authorized officer (Name and title of corporate officer) Builders License No. Plumbers License No. Electricians License No. Other Trade's License No. 1. Location of land on which proposed work will be done: House Number Street Hamlet County Tax Map No. 1000 Section Subdivision (Name) Block ~-~- Lot '~C_e Filed Map No. Lot 2. State existing use and occupancy of premises and intended use and occupancy of pJoposed construction': a. Existing use and occupancy b. Intended use and occupancy 3. Addition ~ Alteration Other Work Nature of work (check which applicable): New Building Repair Removal Demolition Estimated Cost ~o1~ If dwelling, number of dwelling units If garage, number of cars /4/? Fee (Description)" (To be paid on filing this application) Number of dwelling units on each floor 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of existing structures, if any: Front Height. Number of Stories Rear Depth Dimensions of same structure with alterations or additions: Front Depth Height Number of Stories 8. Dimensions of entire new construction: Front Rear Depth Height Number of Stories 9. Size oflot: Front &7,12 .~4~? ' Rear 10. Date of Purchase ~ ,%6CO Name of Former Owner 11. Zone or use district in which premises are situated Rear Depth 12. Does proposed construction violate any zoning law, ordinance or regulation? YES__ NO ~ 13. Will lot be re-graded? YES__ NO /Will excess fill be removed from premises? YES NO 14. Names of Owner ofpremises~- /~/AkJt¢E/- Address/,,4crD/~;SAt ~ ~w~ Phone No. ~31 '7~ '~1 Name ofArchitect R,t,q~ ~,55Otfi~,~/"F--,5 Address~__O//~/~//:l ~,~ PhoneNo ~3l Ee of Contractor_ Address , .Phone No. his property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO S, SOUTHOLD TOWN TRUSTEES & D.E.C. PERMITS MAY BEJgEQUIR~. b. Is this property within 300 feet of a tidal wetland? * YES NO · IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey, to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. STATE OF NEW YORK) SS: COUNTY OF '~ ,~tl~_) ~-~.oO-,~ ~,~ ~O~V~ [' being duly swom, deposes and says that (s)he is the applicant (Name of individual signing contract) above named, (S)He is the (~ c_,a ,,-,e ~] (Contractor, Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are tree to the best of his knowledge and belief; and that the work will be Swo~, to before Cthis /"~ cf-~,, dap of ~ ~7/NotarY Public ' - / / / / Notary Public, Sta..t~of New York (.~ Qualified in ,~olk County No, 01,~C'472508~_ ,-~ Term Expire{'Ma¥ 310 performed in the manner set forth in the application filed therewith. Signature of Applicant Towa H~ Am~c 543?5 ~ Read l~.O. Bo~ 1179 Southold, NY 11971-09~ BUILDING DEPARTMENT TOWN OF SOUTI:IOLD APPLICATION FOR ELECTRICAL INSPECTION REQUESTED BY: Company Name: Name: License No.: JOB8ITE INFORMATION: (*lnd.i~tes required information) *Name: *Address: *Phone No.: T~-MSP Pist~ct: ~000 ~e~ion: ~ ~ Block: ~ LOf:~ ' *BRIEP DESORIPTION OF WORK (Please P~nt Olea~y) (Please Circle All That Apply) *Is job ready for inspection: *Do.you need a Temp Cerfiticate: Temp Information (If needed) *Sell/ice Size: 1 Phase 3phaSe 100 Service: Re-connect Underground Additienal Information: YES I NO Rough In Final YES / NO 150 200 300 350 .400 Other Number of Meters Change of Service overhead PAYMENT DUE WITH APPLICATION 82~equest fo~ Inspection Form TOWN. OF SOUTHOLD PROPERTY RECORD CARD OWNER ~nFORMER OWNER STREET tN S~, ,/~o VI LLAGE DIST. j SUB. LOT ACR, TYPE OF 8UI~DIN~ W RE,. ?/S LAND /76 ~ ,/':7 oo SEAS. IMP. I 7o o d~ 800 VL. TOTAL FARM DATE /o 500 / '1 ,/,/,;r CO 'M~, CB. MICS. Mkt. Value Tillable FRONTAGE ON WATER Woodland Meodowland FRONTAGE ON ROAD DEPTH House Plot I BULKHEAD Total ..,t/z, v,q:~z, 0 COLOR ~ ,~Z~.'/U~ TRIM ~H i-r~ M. Bldg. (& ~ ~/7 : Extension g, x I & · Extension Extension Porch Porch Breezeway Garage Patio Total :. Foundation Basement , Ext. Walls Fire Place Both Floors ,Interior Finish Heat Rooms 1st Floor Type Roof Recreation Room Rooms 2nd Floor Dormer Driveway Dinette K. FIN. B BUILDING PERMIT EXAMINER CI:[ECK LIST DATE REVIEWED: ~ ~/03 APPLICANT: ~&,.~_x~-d~ ~ k3-~~ DATE SUBMITTED: ~ /~-¢/03 SCTM# DISTRICT: 1,000, SECTION: lOCI , BLOCK: ~ , LOT: oQ~ SUBDIVtSION:"~ BUILDING PERMITS OPEN/EXPIRED: 0 A~o~ BP 5q~c>q -Z / C/0 Z-~., 1NFO k~lb~ / BPc-~O~%oq -Z / C/0 Z-oq. oqzlot, 1NF BP,_.~'7)-~-Z / C/0 Z<~_q (:,gq, 1NFO }~a© /BP -Z/C/0 Z- ,INFO PRE CO: Y OR N BP -Z / C/0 Z- , SINGLE & SEPARATE CERTIFICATION-REQUIRED ~ NOTES: -- PANEL #: _~/--gg.- _ FLOOD ZONE: LOTS 40,000SF -100-24 Lot recognition (CREATED before June 30, 1983), UNDERSIZED l~1,.q.,ra~al~44~:199*?+00:25 Merger (A nonconfom~ing at any t/me ariel 7/1/: REQ. LOT SIZE:~ ACT. LOT S1ZE:~REQ. LOT COV. ~O~_~ACT. LOT COV. REQ. FRONT ,tS-C-') PROP. FRONT~_REQ SIDE--ACT. SIDE ..... & ...... --'~ REQ. REAR_ ~(~ PROP. REAR .-+.'.'.'.'.'.'.'.'.'I~REQ. HEIGHT PROP. HEIGHT PROJECT DESCRIPTION: ~:~ ESTIMATED PROJECT COST ~q,..~l~_ &x~'IZHI'I__.-E'~T/ENGINEER:TtZEti~_~.._. FAST TRACK Mc., WATER FRONT? ~O DESCRIPTION: _ ~.z~__ _, COMPLIANCE: APPROVALS REQUIRED SUFFOLK COUNTY HEALTH_ ~]~.PT: 'rES o~ (BED #): TOWN SEPTIC RECEIPT. Y 0r~__~ NEW YORK STATE DEC: PRE-~ECg/1/% YES of~N_~O SOUTHOLD TOWN TRUSTEES: YES TOWN ZONING BOAIU) APPROVAL: YES TOWN PLAN. BOARD APPROVAL: YES TOWN HISTORICAL PRE (SPLIA): YES or NEW YORK STATE CODE COMPLIANCE (SEE PAGE 2): F.~z~r NO NOTES: DTE: / / PERMIT #: FEE STRUCTURE: FOUNDATION: FIRST FLOOR: SECOND FLOOR: OTHER: TOTAL: SF SF SF SF SF INIT O'?HER TOTAL FEE FEE FEE 1. ( SF)- ( SF X $ $ +$ ~ $ :: $ 2.(__ _ SF)-( q: ,t) SFX$ 3. · St:)- ( 819 Sl: X $ FINAL TOTAl,: $ NEW YORK STATE CODE COMPLIANCE CHECKLIST USE/OCCUPANCY CLASSIFICATION: HEIGHT/FIRE AREA: T'SrpE OF CONSTRUCTION: DESIGN CRITERIA: ENG1NEERE~SCRIP~'I~E ~'~3gA FULL FRAMING DESIGN ELEMENTS: HEADERS ~YN WALL STUDS: ~/N GIRDERS: ~ CEILING JOISTS: ~ FLOOR JOISTS: ~yN ROOF RAFTERS: O/N LUMBER SPECIES AND GRADE'~N DESIGN LOAD CALCULATIONS: ~q v/' SHOULD INCLUDE L~WE, DEAD, SNOW, SEISMIC AND WIND (INCLUDING UPLIFT AND EXPOSURE) WINDOW AND DOOR SCHEDULE: MIS SLE TEST REQUIREMENTS: ~/N EGRESS, LIGHT, VENT: Y/N LOAD PATHS: Y/N ~// ROOF TO FOUNDATION NAILING/CONSTRUCTION SCHEDULE:(~ MEANS OF EGRESS: Y/N ~'/ PLUMBING RISER DIAGRAM~/N LOCATION OF FIRE PROTECTION EQUI?MENT: Y/N TRUSS DESIGN: Y/N CERTIFICATION: Y/N ENERGY CALCS:~/N TOTAL COMPL~ (RETURN TO PAGE ONE Town Hall, 53095 Main Road P.O. Box 1179 Southold, New York 11971-0959 Fax (631) 765-9502 Telephone (631) 765-1802 BUILDING DEPARTMENT TOWN O1' SOUTHOLD May 30th, 2006 Edward E. Wankel P.O. Box 1275 Cutchogue, N.Y. 11935 RE: 1200 Praity Lane SCTM # 109 0005 026 Dear Mr. Wankel, Please be advised that your Building Permit # 29435 issued May 28th, 2003 has expired. According to the Code of the Town of Southold, a Certificate of Occupancy must be issued prior to use of the structure. To renew your Building Permit, please submit a fee of $150.00 at that time we can schedule an inspection by one of our Building Inspector's. If you have any questions, please call us at 631-765-1802. Respectfully, SOUTHOLD TOWN BUILDING DEPT. Town Hall, 53095 Main Road P.O. Box 1179 Southold, New York 1197 -_//~ ~BUI~LL ING DEPARTMENT ,, TOWIq[ OF SOUTHOLD Fax (631 ) 765-9502 Telephone (631 ) 765-1802 March 20th, 2007 Edward E. Wankel P.O. Box 1275 ~./ Cutchogue, N.Y. 11935J/ RE: 1200 Praity La. (alteration/addition) SCTM: 109 5 26 2~v~ NOTICE Dear Mr. Wankel, Please be advised that your Building Permit #29435 issued May 28th, 2003 has expired. According to the Code of the Town of Southold, a Certificate of Occupancy must be issued prior to use of the structure. To renew your Building Permit, please submit a fee of $150.00; at that time we can schedule an inspection by one of our Building Inspector's. If you have any questions, please call us at 631-765-1802. Respectfully, SOUTHOLD TOWN BUILDING DEPT. Town Hall, 53095 Main Road P.O. Box 1179 Southold, New York 11971-0959 Fax (631) 765~9502 Telephone (631) 765-1802 BUILDING DEPARTMENT TOWN OF SOUTI-IOLD February 21st, 2008 FINAL NOTICE Edward E. Wankel /.. ~, P.O. Box 1275 Cutc hogue, N. 15 11935 RE: 1200 Praity Lane. (Alteration/Addition) SCTM: 109.-5-26 Dear Mr. Wankel, Please be advised that your Building Permit # 29435 issued May 28th, 2003 has expired According to the Code of the Town of Southold, a Certificate of Occupancy must be issued prior to use of the structure. To renew your Building Permit, please submit a fee of $150. 00; at that time we can schedule an inspection by one of our Building Inspector's. If you have any questions, please call us at 631-765-1802. Respectfully, SOUTHOLD TOWN BUILDING DEPT Town Hall Annex 54375 Main Road P.O. Box 1179 Southold. New York 11971-0959 Telephone (631 ) 765 1802 Fax (631 ) 765-9502 BUILDING DEPARTMENT TOWN OF SOUTHOLD ~Tanuary 21st, 2009 Edward Wankel ,Tudith Gordon P.O. Box 1275 Cutchogue, N.Y. 1193§ Re: 1200 Pr.airy Lane / yJolatiorl $CTM# 1000-109. -§-26 To Whom This May Concern: Your' BUTLDI'N& PERMIT # 29435 for construction of an ALTERATION/ADDrI-ZON has been referred to me because you hove not responded to requests to obtain your Certificate of Occupancy as required by 5outhold Town code. Pursuant to 144-1§A, of the $outhold Town Code, "No building hereafter erected shall be used or occupied in whole or in part until a certificate of occupancy shall have been issued by the Building Inspector." Therefore, you have ten days from the receipt of this letter to submit a check made out to the Town of 5outhold in the amount of $1§0.00: to renew the building permit, or legal action will be taken against you. Should you have any questions, call the building department between the hours of 8:00 a.m. and 4:00 p.m. Respectfully Yours, Damon Rallis, Zoning Inspector Southold Building Department Southold Town Building Department P.O. Box 1179 Permit #: 35362 54375 Main Road Southold, New York 11971 Permit Date: 3/1/2010 (631) 765-1802 Expiration Date: 9/1/2011 Parcel ID: 109.-5-26 BUILDING PERMIT RENEWAL LETTER Dated: 5/30/2012 Applicant: EDWARD WANKEL & JUDITH GORDON Location: 1200 PRAITY LANE CUTCHOGUE Work Description: ADDITION/ALTERATION ADDITIONS & ALTERATIONS TO AN EXISTING SINGLE FAMILY DWELLING AS APPLIED FOR.REPLACES EXPIRED BP # 29435 A FEE OF $75.00 IS REQUIRED TO RENEW THIS BUILDING PERMIT. Address: EDWARD WANKEL & JUDITH GORDON P.O. BOX 1275 CUTCHOGUE, NY 11935 The permit listed above has expired. Please contact our office as soon as possible to begin the renewal process. Ail work on thc project must stop on the expiration date. No work is permitted or authorized beyond the expiration date. THANK YOU, SOUTHOLD TOWN BUILDING DEPT. · Pflnt your name and address on the reverse so that we can return the card to you. · Attach this card to the back of the mallplece, or on the front If space permits. 1. Article Addressed to: P. //?55- 2. Article Number D, Isdeli~addressdiff~rent fmmltem'l?' I~ y~ If YES, enter delivery address below: [] No 4. Res~lcted Delivery? (Ex/m Fee) I Permit No. G-lO · Sender: Please print your name,~address, and ZIP+4 in this box · TOWN OF $OUTHOLD BUILDING DEPARTMENT P.O, Box 1179 8oulho~ N.Y. 11971 · Complete items 1,2, and 3. Also complete item 4 if Restricted Delivery is desired. · Print your name and address on the reverse so that we can return the card to you. · Attach this card to the back of the mailpiece, or on the front if space permits. 1. Article Addressed to: ~:~ ~ ~ /~ ~,~ ,~. Received by (Pdnted Name) D. Is delivery address different from itern l ? []Yes If YES, enter delivery address below: [] No 3. Service Type [] Certified Maid [] Express Maid [] Registered [] Return Receipt for Merchandise [] Insured Mail [] C.O.D. 4. Restricted Delivery? (Extra Fee) [] Yes 2. Article Number (Transfer from service label) PS Form 3811, February 2004 Domestic Return Receipt 102595-O2-M-1540 o. G-lO · $ondor: Pleaso print your namo, addreas, and ZIP+4 in this box ° TOWN OF $OUTHOLD BUILDING DEPARTMENT P.O, Box 1179 Southok], N.Y. 11971 · Complete items 1~ 2,.and 3. Also complete item 4 if Restricted D~livery ie desired. bo that we can return th~to you. · Attach this card to the I~sl~ ~f the id~l~iece, or on the front if space perrfiit~. (~ ~'~'~L~ / B. R~i~ by (m,t;~W;~) ~. ~, of ~,vor~ D. I~ delivery address different frcrn item 1 ? [] Yes If YES, enter delivery address below: [] NO 3. Service Type r-I Certified Mail [] Express Mall [] Registered [] Return Receipt for Memhandlse [] Insured Mail [] C.O.D. 4. Restricted Deliver? (Extra Fee) [] Yes 2. Article Number PS Fo~ 381 ~ Februa~ 2004 ~mestlc Return Re~ipt lO2~-~1~ I · Sender: Please print your name, address, and ZIP+4 in this box · TOWN OF SOUTHOLD BUILDING DEPARTMENT P.O. Box 1179 Southo/d, N.Y. 11971 Southold Town Building Department P.O. Box 1179 54375 Main Road Southold, New York 11971 (631) 765-1802 Parcel ID: 109.-5-26 Permit #: 35362 Permit Date: 3/1/2010 Expiration Date: 9/1/2011 BUILDING PERMIT RENEWAL LETTER FINAL NOTICE Applicant: Location: Work Description: Dated: 11/16/2012 EDWARD WANKEL & JUDITH 6ORDON 1200 PRAITY LANE CUTCHOGUE ADD ~'TT ON/ AL TERA T'.r. ON ADDITION5 & ALTERATION5 TO AN EXTSTING 5INGLE FAMILY DWELLTNG A5 APPLZED FOR.REPLACE5 EXPIRED BP # 29435 A FEE OF $125.00 15 REQUIRED TO RENEW THIS BUILDIN~ PERMIT. Owner: Address: EDWARD WANKEL & JUDITH GORDON P.O. BOX 1275 CUTCHOGUE, NY H935 The permit listed above has expired. Please contact our office ns soon as possible to begin the renewal process. All work on the project must stop on the expiration date. THANK YOU, $OUTHOLb TOWN BUILbIN~ DEPT. Permit Number REScheck Compliance Certificate New York State Energy Conservation Construction Code REScheckSof~ware Version 3.5 Release lb Data filename: C:~Program Files\Check~REScheck\WANKEL.rck TITLE: WANKEL / GORDON RESIDENCE ADDITION Checked By/Date COUNTY: Suffolk STATE: New York HI)D: 5750 CONSTRUCTION TYPE: Detached 1 or 2 Family HEATING TYPE: Non-Electric DATE: 05/13/03 DATE OF PLANS: 4-29-03 COMPANY iNFORMATION: WARD ASSOCIATES, P.C. COMPLIANCE: Passes Maximum UA = 46 Your Home UA = 44 4.3% Better Than Code (UA) Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA Ceiling 1: Cathedral Ceiling (no attic) 128 30.0 0.0 4 Skylight 1: Wood Frame:Double Pane with Low-E 6 0.240 1 Wail 1: Wood Frame, 16" o.c. 288 19.0 0.0 14 Window 1: Wood Frame:Double Pane with Low-E 20 0.340 7 Window 2: Other 32 0.440 14 Floor 1: Ail-Wood Joist/Truss:Over Unconditioned Space 128 30.0 0.0 4 COMPLIANCE STATEMENT: The proposed building represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed systems have been designed to meet the New York State Energy Conservation Construction Code requirements. When a Registered Design Professional has stamped and signed this page, they are attesting that to the best of his/her knowledge, belief, and professional judgment, such plans or specifications are in ~mpliance wither h _ B uilder/Designer ~'"~ ~ l~t'~tr;/~t-~ ~ REScheck Inspection Checklist New York State Energy Conservation Construction Code REScheckSoftware Version 3.5 Release lb DATE: 05/13/03 TITLE Bldg. Dept. Use [ ] £ ] [ ] [ I [ ] [ ] [ ] [ ] [ ] [ ] [ 1 [ ] 3RDON RESIDENCE ADDITION Ceilings: 1. Ceiling 1: Cathedral Ceiling (no attic), R-30.0 cavity insulation Comments: Above-Grade Walls: t. Wall 1: Wood Frame, 16" o.c., R-19.0 cavity insulation Comments: Windows: 1. Window 1: Wood Frame:Double Fane with Low-E, U-factor: 0.340 For windows without labeled U-factors, describe features: # Panes Frame Type_ Thermal Break? [ ] Yes [ Comments: ] No Window 2: Other, U-factor: 0.440 For windows without labeled U-factors, describe features: # Panes Frame Type Thermal Break? [ Comments: ] Yes [ ] No Skylights: 1. Skylight 1: Wood Frame:Double Pane with Low-E, U-factor: 0.240 For skylights without labeled U-factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ Commants: ] No 1. Floor 1: All-Wood Joist/Tress:Over Unconditioned Space, R-30.0 cavity insulation Comments: Air Leakage: Joints, penetrations, and all other such openings in the building envelope that are suureas of air leakage must be sealed. Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air-fight assembly with a 0.5" clearance from combustible materials. If non4C rated, the fixture must be installed with a 3" clearance from insulation. Vapor Retarder: Required on the warm-in-winter side of all non-vented framed ceilings, walls, and floors. Materials Identification: Materials and equipment must be installed in accordance with the manufa~tureis installation instructions. Materials and equipment must be identified so that compliance can be determined. Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. Insulation R-values and glazing U-factors must be clearly marked on the building plans or specifications. Duct Insulation: Supply ducts in unconditioned attics or outside the building must be insulated to R-8. Return ducts in unconditioned attics or outside the building must be insulated to R-4. Supply ducts in unconditioned spaces must be insulated to R-8. Return ducts in unconditioned spaces (except basements) must be insulated to R-2. Insulation is not required on return duets in basements. Duct Construction: Ail joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives), mastic-plus-embedded-fabric, or tapes. Duct tape is not permitted. Exception: Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa). Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions. Cooling ducts with exterior insulation must be covered with a vapor retarder. Air filters are required in the return air system. The HVAC system must provide a means for balancing air and water systems. Temperature Controls: Each dwelling unit has at lesat one thermostat capable of automatically adjusting the space temperature set point of the largest zone. Electric Systems: Separate electric meters are required for each dwelling unit. Fireplaces: Fireplaces must be installed with tight fitting non-combustible fireplace doors. Fireplaces must be provided with a soume of combustion air, as required by the Fireplace construction provisions of the Building Code of New York State , the Residential Code of New York State or the New York City Building Code, as applicable. Service Water Heating: Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part ora circulating system. Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: All heated swimming pools must have an on/oft'heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: HVAC piping conveying fluids above 105 °F or chilled fluids below 55 OF must be insulated to the levels in Table 2. Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pipe Sizes Heated Water Non-Circulating Runouts Temperature (F) Up to 1" Up to 1.25" 170-180 0.5 1.0 1.5 2.0 140-t60 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Circulating Mains and Runouts 1.5" to 2.0" Over 2" Table 2: Minimum lnsulation Thlckness for HVAC Pipe~ Piping System Tgoes Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 Low Temperature 120-200 0.5 1.0 Steam Condensate (for feed water) Any 1.0 1.0 Cooling Systems Chilled Water, Refrigerant, 40-55 0.5 0.5 and Brine Below 40 1.0 1.0 Fluid Temp. Insulation Thickness in Inches b,y Pipe Sizes Range (F) 2" Runouts I" and Less 1.25" to 2" 2.5" to 4" 1.5 2.0 1.0 1,5 1.5 2.0 0.75 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only) GENERAL CONSTRUCTION 1. GENERAL PROJECT INCLUDES THE CONSTRUCTION OF A NEW RESIDENCE INCLUDING RUT NOT LIMITED TO EXCAVATION, FOUNDATIONS, UTILITIES, FRAMING, iNSULATION, WINDOWS AND DOORS, FINISHES, SIDING, ROOFING, PLUMBING, HVAC AND ELECTRICAL SYSTEMS, LANDSCAPING AND PAVEMENTS. CONTRACTOR SHALL OBTAIN ALL PERMITS, UL CERTIFICATES AND FINAL C,O, 2. CONCRETE - 3500 PSI AT 28 DAYS ASTM 94 READY-MIXED CONCRETE, 3. STEEL BAR REINFORCING - ASTM 615 WELDED WIRE FABRIC - ASTM A-135. 4. STRUCTURAL STEEL - (LINTELS, PLATE, GIRDERS, ETC.) TO BE ASTM A-572 GRADE PRIME PAINTED. 5. VAPOR BARRIER - ASTM E-96 POLYETHYLENE FILM 6 MIL THICK WITH TAFED SEAMS. 6. LUMBER A. DOUGLAS FIR NO. 1 GRADE WiTH BASE Fb = 1000 PSI AND E = 1,700,000, 19% M.C. mox. B. PLYWOOD i/SUBFLOOR - 3/4' TH., C-D INTER,OR APA WITH EXTERIOR GLUE. /PL-PREMIUM GLUE DOWN WITH NAILING) WALL SHEATHING - 5/B" EXTERIOR GRADE APA, FIR PLYWOOD ROOF SHEATHING - 24/0, 3/4" TH., C-D EXTERIOR APA, FIR PLYWOOD. MARBLE & TILE SUBFLOORS - 3/4" TH. C-D EXTERIOR APA, (PL-PREMIUM GLUE DOWN WITH NAILING) WITH UNDERLAYMENT - 1/4" AC PLYWOOD (FIR). C. CONNECTORS - SIMPSON STRONG-TIE OR EQUAL, ALL TO BE GALVANIZED. D.SILLS - SOUTHERN YELLOW PINE #2 OR BETTER, CCA TREATED (.40 PCF) KDAT. E. SOFFITS: 3/8" EXT. GRADE A-C PLYWOOD APA. PRE-STAIN ALL SURFACES WITH SOLID STAIN TO MATCH SIDING. 7. ROOFING - GAF TIMBERLINE ULTRA WITH TIMBERTEX RIDGE MATERIAL, ICE AND WATER-SHIELD AT VALLEYS/EAVES. 8. LEADERS & GUTTERS - 6" COMMERCIAL ALUMINUM GUTTERS AND LEADERS, COLOR SHALL BE AS SELECTED. PROVIDE CONTINUOUS LEAF GUARDS AND ROOF HANGERS AT 30" MAXIMUM. 9. SHEET METAL FLASHINGS & ROOFING - SHALL BE 16 OUNCE COPPER AT ALL ROOF PENETRATIONS AND WALL/ROOF INTERSECTIONS, AND ROOFING. 10. TERMITE SHIELDS - SHALL BE .019" ALUM. WITH SEALANT JOINTS AT LAPS AND BOLT PENETRATIONS. 11, PROVIDE SILL SEALER (POLYETHYLENE) UNDER CCA STILL PLATES, 12. FASCIA & WOOD TRIM - CLEAR CEDAR, 5/4 x 6 FASCIAS, 1 x 3 TRIM, 5/4 x 4 CASING AND OTHER TRIM AS SHOWN. ON THE ELEVATIONS. BACKPRIME AND PRE-STAIN ALL EXTERIOR WOOD. ! 13. S~DING - CLEAR BEVEL CEDAR SIDING - PERFECTIONS. PRE-STAIN WITH SOLID STAIN.(CABOT'S, BENJAMIN MOORE, ,/ OLYMPIC) INSTALL OVER TYVEK HOUSEWRAP WITH TAPED SEAMS. 14. WALL BASE - 1" x 6" HEIGHT CLF~AR CHERRY WITH OGEE TOP EDGE. 15, INSULATION - FIBERGLASS & RIGID INSULATION. BATTS WITH VAPOR BARRIER BY OWENS-CORNING, THICKNESS AS FOLLOWS: A. R-'30C - BETWEEN RAFTERS (VENT SPACE ABOVE) 12" ABOVE ATTIC CEILING (FLAT AREAS) B. R-30" - BETWEEN CRAWL SPACE AND FIRST FLOOR. C. 2" - EXTRUDED POLYSTYRENE RigiD iNSULATION, R-lO MIN. MASTIC APPLICATION. 16, DOORS AND WINDOWS A. INTERIOR DOORS, SOLID WOOD, 4 PANEL DOORS. STAIN/POLYURETHANE FINISH AS SELECTED. B. WINDOWS AND GLASS DOORS - ANDERSEN CO., "STORMWATCH", PERMA-SHIELD HIGH PERFORMANCE, COLOR AS SELECTED. ALL WITH SCREENS TO MATCH. PROVIDE EXTENSION dAMES, MARINE GRADE EGRESS HARDWARE- FINISH AS SELECTED. C.DOOR FRAMES - TO BE MADE UP FROM 5/4" CHERRY WITH INTEGRAL STOP AND BUILT- UP WOOD INTERIOR TRIM 5/4 x4 WITH PROFILED EDGE AS SELECTED. MITER ALL CUTS. 17. CAULKING - LEXCEL EXTERIOR; ACRYLIC LATEX INTERIOR. 18. ADHESIVES - PL PREMIUM AS MANUFACTURED BY CONTECH BRANDS (TO BE USED IN ADHERING PLYWOOD SUBFLOOR TO FLOOR dOISTS). 19. HARDWARE A. LOCKSETS - BALDWIN 5440 LEVER TYPE OR AS SELECTED. FUNCTION TO MATCH SPACE UTILIZATION. FINISH AS SELECTED, B. HINGES - HAGER, STANLEY OR EQUAL - BALL TYPE FINIALS, REMOVABLE PINS. C. MISCELLANEOUS - STANLEY (CAB. PULLS, ETC.). D. STOPS - FLUSH BOLTS, PULLS, BUMPERS - IVES. , 20. GYPSUM BOARD A, INTERIOR WALLS AND CEILINGS, 5/8" THICK, TAPE AND SPACKLE ALL JOINTS. B. BATHROOM WALLS AND CEILINGS, 5/8" THICK WR, TAPE AND SPACKL-. C. WONDERBOARD FOR TUB SURROUNDS AND TILE SHOWERS. 21. MARBLE AND CERAMIC TILE & WALLBASE - AS SELECTED BY OWNER. PROVIDE $4,000 LABOR AND MATERIAL ALLOWANCE, 22. CABINETS & BATHROOM VANITIES - AWl CUSTOM QUALITY WITH MARBLE COUNTER TOPS, UNITS SHALL INCLUDE BATH VANITIES AND BASE CABINETS, JACUZZI TUB SURROUND AND LINEN STORAGE SHELVES. PROVIDE ALLOWANCE AMOUNT OF $2500 FOR MATERIALS, FABRICATION AND INSTALLATION, 24. PAINTING A. EXTERIOR WALLS - WOOD SIDING, SOFFITS, FASCIA AND TRIM - SOLID STAIN, TWO (2) COATS. COLOR AS SELECTED. MATCH EXISTING. B. INTERIOR WALLS - ONE (1) COAT SEALER, TWO (2) COATS FLAT - COLOR AS SELECTED. BATHROOM - SATIN FINISH. BENJAMIN MOORE. C. ALL INTERIOR WOODWORK - ONE (1) COAT SEALER, TWO (2) COATS SATIN FINISH, POLY OR COLOR AS SELECTED. BENJAMIN MOORE. 25. BATHROOM ACCESSORIES (SUPPLIED BY OWNER, INSTALLED BY CONTRACTOR). A. TWO (2) TOWEL BARS B, TOILET PAPER DISPENSER C, ROBE HOOKS - TWO D. SHOWER ENCLOSURE - LUXUS SERIES 30, NEO ANGLE FRAMELESS, TEMPERED GLASS 26. CLEANUP - PROVIDE GENERAL CLEANUP OF PROJECT SITE DURING CONSTRUCTION, AND AT COMPLETION OF PROJECT PROVIDE FINAL "MOVE IN" CLEANING OF WINDOWS, DOORS, FLOORS AND WOODWORK INCLUDING ANY NECESSARY PAINT TOUCHUP. 31. GENERAL NOTES A. ALL WORK TO BE DONE IN ACCORDANCE WITH THE LOCAL BUILDING AND NEW YORK STATE ENERGY CONSERVATION CONSTRUCTION CODE, NEW YORK STATE RESIDENTIAL CODE AND THEiSE OF THE LOCAL GOVERNING AUTHORITIES. B.SOIL BEARING PRESSURE ASSUMED TO BE 2,000 PSF. C.ALL FOOTINGS TO REST ON UNDISTURBED SOIL. D.PROVIDE ALL STEEL LINTELS, BOLTS, PLATES, GIRDERS AND FASTENERS AS REQUIRED, SHOP COAT ALL STEEL, E. STRUCTURAL STEEL SHALL COMPLY TO THE SPECIFiCATiONS FOR DESIGN, FABRICATION AND CONSTRUCTION OF STEEL FOR BUILDING OF THE A.I.S,C, ASTM A-572. F, ALL FRAMING AND CONNECTIONS SHALL BE IN ACCORDANCE WITH TIle LATEST EDITION OF THE NATIONAL DESIGN SPECIFICATIONS FOR STRESS GRADED LUMBER AND ITS FASTENINGS AS PUBLISHED BY THE N.F.P.A. DESIGN BASED ON PRESCRIPTIVE DESIGN FORMAT AS PER THE WOOD FRAME CONSTRUCTION MANUAL-HIGH WIND EDITION. G.DOUBLE JOIST UNDER PARTITIONS WHICH RUN PARALLEL TO FLOOR dOISTS, AND AROUND OPENINGS. H. WOOD SILLS SHALL BE ACQ TREATED, .40 PCF, KDAT 15. PROVI[~E 1/2 INCH DIAMETER ANCHOR BOLTS AT 6'-0" O.C. MAX. PROVIDE 2 BOLTS PER SILL PIECE MINIMUM AND PLACE 1'-0" FROM CORNERS MAX. I. PROVIDE GALVANIZED CONNECTORS OF ALL BUTR STRUCTURAL CONNECTIONS AND TO MAINTAIN A CONTINUOUS LOAD PATH FROM RIDGE TO FOUNDATION.. d. CAULK OR FOAM ALL EXTERIOR WALL PLATE AND SHEATHING OPENINGS, PENETRATIONS OF ELECTRICAL, PLUMBING, AND VENTING. K. PROVIDE ALL TEMPORARY RAILINGS AND SAFETY DEVICES FOR ALL TRADES DURING THE CONSTRUCTION OF THE PROJECT, L. CONTRACTOR TO DO ALL PATCHING NECESSARY TO REPAIR DAMAGE MADE DURING CONSTRUCTION ACTIVITIES. PATCHING TO MATCH AND MEET FLUSH UNLESS NOTED OTHERWISE. M. CONTRACTOR TO FIELD VERIFY ALL CONDITIONS AT THE SITE PRIOR-TO CONSTRUCTION. DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS SUPERSEDE SCALED DIMENSIONS. O. ALL EXTERIOR NAILING SHALL BE STAINLESS STEEL OR HOT-DIPPER GALVANIZED. p. PROVIDE ONE ROW OF 5/4" X ,3" WD. CROSS BRIDGING FOR EACH 8'-0" OF SPAN. Q, PROVIDE ACCESS DOORS IN HOUSE FRAMING TO ACCESS JACUZZI AND MECHANICAL EQUIPMENT. PLUMBING 1. GENERAL - FURNISH ALL LABOR, MATERIALS, EQUIPMENT, PLANS, TOOLS, AND SERVICES NECESSARY AND REQUIRED FOR PROPER AND COMPLETE INSTALLATION OF ALL PLUMBING SYSTEMS AND RELATED WORK TO INCLUDE BUT NOT BE LIMITED TO, WATER SUPPLY AND DISTRIBUTION PIPING, DRAINAGE PIPING, PLUMBING FIXTURES, VALVES, TRAPS, WASTE AND VENT PIPING, INCLUDING ALL THEIR RESPECTIVE CONNECTIONS, DEVICES, APPURTENANCES WITHIN THE ADDITION AREA. PLUMBING FIXTURES TO INCLUDE, BUT NOT BE LIMITED TO: LAVATORIES, JACUZZI TUB, SHOWER, BIDET AND WATER CLOSET. RELOCATE EXTERIOR HOSE BIB AND IRRIGATION SYSTEM PIPING. 2, CODES - ALL WORK SHALL CONFORM TO THE REQUIREMENTS OF THE CODE(S) HAVING JURISDICTION .3. PIPING - COLD/HOT WATER AND PIPING - TYPE L. COPPER TUBING (ANSI H231) WITH SOLDER TYPE FRTINGS AND JOINTS MADE WITH 95/5 SOFT METAL SOLDER. BELOW GROUND PIPING TO BE TYPE K COPPER TUBING, RISERS AND MAINS TO BE 3/4 INCH, ALL BRANCH LINES TO FIKTURES TO BE 1/2 INCH, PROVIDE SHUTOFF AND DRAIN VALVE IN CRAWL SPACE FOR EACH RISER AND PROVIDE VALVE TAG IDENTIFICATION. 4. DRAINAGE PIPING - SANITARY PIPING SHALL BE COPPER OR PVC. PROVIDE CONNECTION TO EXISTING RESIDENCE SANITARY DRAIN SYSTEM, 5. SANITARY VENT PIPING - PVC PIpe AND FITTINGS OR AS REQUIRED BY LOCAL CODE, 6, FLASHING - FLASHING MATERIALS TO BE 16 OZ. COPPER MIN. 7, HOSE BIB - HOSE BIBS TO BE NON-FREEZE TYPE WITH INTERIOR SHUTOFF VALVE. 8. PLUMBING FIXTURES - CONTRACTOR TO PROVIDE ALL ROUGHING, VALVES, FITTINGS, ETC, FOR COMPLETE JOB. (THE OWNER WILL SELECT FIXTURES AND FI~DNGS. ALL RXTURES SHALL BE KOHLER IN COLOR AS SELECTED BY THE OWNER. ALL FITTINGS SHALL BE IN FINISH SELECTED BY OWNER. - WATER CLOSET SHALL BE KOHLER AS SELECTED. - LAVATORIES SHALL BE CAXTON WITH GROHE CLASSIC WITH FINISH FITTINGS AS SELECTED, - WHIRLPOOL BATH SHALL BE KOHLER AS SELECTED. GROHE CLASSIC FITTINGS AS SELECTED. - BIDET SHALL BE KOHLER AS SELECTED WITH OROHE CLASSIO BRASS FITTINGS. - SHOWER FI~FINGS SHALL BE GROHE TWO WALL CUSTOM SHOWER SYSTEM. 9. VALVES - VALVES TO BE BRASS/BRONZE BODY - 125 PSIG. ALL VERTICAL SUPPLY RISERS AND BRANCH LINES SHALL BE PROVIDED WITH DRAIN TEES AND SHUTOFF VALVES IN THE CRAWL SPACE, 10. CLEANOUTS - CLEANOUTS TO BE FULL SIZE OF PIPE WITH THREADED BRASS SCREW PLUGS. 11, PLATES - PLATES FOR FINISHED SPACES TO BE CHROME PLATED SPLIT BRASS. 12. PIPE INSULATION - PIPE INSULATION TO BE CELLULAR FOAM OF THICKNESS REQUIRED BY THE ENERGY CONSERVATION CONSTRUCTION CODE*, P,~OVlDE ON ALL INTERIOR COLD AND HOT WATER AND AIR HANDLER PIPING. 13. HOT WATER STORAGE - 40 GALLON STAINLESS STEEL TANK WITH 2" FOAM INSULATION, CUPRONICKEL HEAT EXCHANGER, THERMOSTATIC ALLY CONTROLLED, SUPER - STOR ~,~ODEL NO,SS-40 AS MANUFACTURED BY HYDRO-THERMAL SYSTEMS, INC. OR APPROVED EQUAL, PROVIDE COMPLETE WITH TEMPERATURE GAUGE AND RELIEF VALVE. 14. CIRCULATORS - CIRCULATOR, ONE FOR THE HEATIN¢ ZONE, ONE FOR THE WATER HEATER, AND ONE FOR RADIANT HEAT ZONE (IF USED) TO BE B & G, SERIES 10, SIZED FOR APPROPRIATE GPM WITH SETTLEABLE FLOW CHECK, PIPE SIZE 1 INCH, SEALS TO BE SUITABLE FOR GLYCOL SOLUTION. CONNECT PIPING TO EXISTING HOT WATER HEATER AND BOILER. 15, WATER SOFTENER - PROVIDE AND INSTALL MERMAID ACID NEUTRALIZER, MODEL NO, AN-'3ORE AND MERMAID WATER SOFTENER, MODEL NO. AST-'3ORE. PROVIDE TWO YEAR PARTS AND LABOR WARRANTY TO OWNER. 16. STEAM SHOWER UNIT - MODEL NO SM-3PB AS MANUFACTURED BY STEAMIST OR EQUAL, LOCATE REMOTE UNIT IN CRAWL SPACE. 17. MANUALS - CONTRACTOR TO PROVIDE ALL PRODUCT LITERATURE, WARRANTIES, AND INSTRUCTION TO OWNER. lB. CLEANUP - CONTRACTOR TO CLEAN UP AND DISPOSE OF DAILY, ALL HIS TRADE RELATED DEBRIS AND WASTE MATERIALS. HVAC 1. GENERAL - FURNISH ALL LABOR, MATERIALS, EQUIPtAENT, PLANS, TOOLS AND SERVICES NECESSARY AND REQUIRED FOR PROPER AND COMPLETE INSTALLATION OF ALL HEATING, VENTILATING, AND AIR CONDITIONING SYSTEM AND RELATED WORK. HVAC SYSTEMS WILL INCLUDE, B~f NOT BE LIMITED TO, AIR HANDLING, VENTING, DUCTWORK, AND ALL SYSTEM RELATED PIPING, VALVING, CONTROLS AND WIRING, ELECTRICAL COORDINATION WITH ELECTRICAL CONTRACTOR FOR LINE VOLTAGE WIRING, AND ALL~qECESSARY DEVICES FOR COMPLETE FULLY OPERATING SYSTEM, 2. CODES - ALL WORK SHALL CONFORM TO THE RE(~UIREMENTS OF THE LOCAL BUILDING CODE(S). 3. HEATING & COOLING SYSTEM - EXTEND EXISTING HVAC ZONE TO NEW ADDITION, WORK SHALL BE COMPLETE WITH DUCTWORK, HEAT EXCHANGER, REGISTERS, GRILLES CONTROLS AND RELATED ACCESSORIES. 4. THERMOSTAT - THERMOSTAT TO BE HEATING/COOLING, DAY/NIGHT SET BACK, DIGITAL, ELECTRONIC TYPE WITH CLOCK. CONTROL WIRING BY HVAC cOr~TRACTOR. 5. DUCT WORK - DUCT WORK TO BE FABRICATED IN ACCORDANCE WiTH SMACNA STANDARDS INCLUDING TRANSITIONS, BENDS, TAKE-OFFS, ETC,, DESIGNED FOR MINIMUM STATIC LOSSES. DUCT MATERIAL TO BE GALVANIZED SHEET METAL OF 26 GAUGE UP TO 24 INCHES WIDE AND 24 GAUGE ABOVE 24 INCHES WIDE. SEAMS AND JOINTS SHALL BE SUCH THAT LEAKAGE IS NOT MORE THAN 3%. DUCTS SHALL HAVE RIGID FIBERGLASS ACOUSTICAL AND THERMAL LINERS, 2 INCH THICK FOR SUPPLY AND 1/2 INCH FOR RETURN. 6. FILTERS - FILTERS SHALL BE SPACE CARD, MODEl. 12200, HIGH EFFICIENCY UNITS. EIGHT INCH DEEP PLEATED UNIT, RATED AT 99% EFFICIENT WITH 6 MICRON SEE PARTICLES. 7. DIFFUSERS - SUPPLY DIFFUSERS TO BE CARNES OR EQUAL. ADJUSTABLE OPPOSED BLADE DAMPERS, WHITE. 8, RETURN GRILLS - HART & COOLEY OR APPROVED EQUAL. WHITE. 9. DUCT WORK - DUCT WORK TO BE INSTALLED TO BE FREE FROM VIBRATION, AND SUPPORTED AT 4 FT, ON CENTER MAX.. DUCT JOINTS SHALL BE PROPERLY SEALED 1 INCH ON EACH SIDE OF JOINT. PROVIDE ISOLATION PADS AND DRIP PANS WITH CONDENSATE PIPING TO EXTERIOR FOR ALL AIR HANDLER UNITS. 10, VOLUME DAMPER - PROVIDE VOLUME DAMPER, OR OTHER APPROVED AIR BALANCING DEVICE, WITH iNDICATING AND LOCKING QUADRANT. PROVIDE AT EACH MAIN DUCI~ AT EACH DUCT TAKE-OFF AND AT EACH NECK TO INDIVIDUAL DIFFUSER OR REGISTER IN SUPPLY, RETURN OR EXHAUST DUCT, 11. ACCESS DOORS - PROVIDE ACCESS DOORS AS REQUIRED FOR COILS, FILTERS, DAMPERS, AND OTHER EQUIPMENT THAT REQUIRE PERIODIC SERVICE. DOORS SHALL BE Or YHE SAME MATERIAL AS THE DUCT WORK AND CONSTRUCTED SO AS TO MINIMIZE LEAKAGE. 12. HEATING & AIR CONDITIONING SYSTEM - HEATING AND AIR CONDITIONING SYSTEM SHALL BE COMPLETE WITH ALL NECESSARY COMPONENTS AND ITEMS NORMALLY S~JPPLIED, SUBSTITUTIONS OF EQUIPMENT SHALL BE APPROVED BY THE ARCHITECT. CONTRACTOR TO PROVIDE ONE YEAR FULL GUARANTEE OF COMPLETE SYSTEM. 13. COMPLETION - AT THE COMPLETION OF THE WORY, ALL EQUIPMENT COMPLETE WITH THEIR FITTINGS SHALL BE PROPERLY CLEANED AND LEFT IN FIRST CLASS WORKING CONDITION. ALL DUCT WORK SHALL BE LEFT CLEAN TO PREVENT SYSTEM DISTRIBUTION OF DUST AND DIRZ SYSTEM SHALL BE LEFT WITH CLEAN FILTERS, 14. MANUALS - CONTRACTOR TO PROVIDE ALL PRODUCT LITERATURE, WARRANTEES, AND INSTRUCTION TO OWNER. 15. CLEANUP - CONTRACTOR TO CLEAN UP AND DISPOSE OF DALLY, ALL HIS TRADE RELATED DEBRIS AND WASTE MATERIALS. WARD ASSOCIATES, P,C, ARCHITECTS, LANDSCAPE ARCHITECTS, ENGINEERS 1500 LAKELAND AVENUE BOHEMIA, N.Y. 11716 (631) 563-4800 fax (631) 563-4800 ELECTRICAL 1. GENERAL - FURNISH ALL LABOR, MATERIALS, EQUIPMENT, PLANS, TOOLS, AND SERVICES NECESSARY AND REQUIRED FOR PROPER AND COMPLETE INSTALLATION OF ALL ELECTRICAL SYSTEMS AND RELATED WORK TO INCLUDE, BUT NOT BE LIMITED TO: INSTALLATIONS OF NEW WIRING, CIRCUITS, LIGHTING, EQUIPMENT CONNECTIONS, DISTRIBUTION AND PROTECTION EQUIPMENT, APPLIANCE CONNECTIONS, AND CONNECTION OF ALL DEVICES WITHIN THE SCOPE OF WORK AS SHOWN ON THE APPLICABLE DRAWINGS AND AS NORMALLY SPECIFIED IN THIS TYPE OF PROJECT. 2. CODES: ALL WORK SHALL CONFORM TO THE REQUIREMENTS OF THE LOCAL BUILDING CODE AND THE NATIONAL ELECTRIC CODE (NEC), LATEST EDITION, '3. CIRCUIT BREAKERS - SINGLE POLE 15 AND 20 AMPERE CIRCUIT BREAKERS SHALL BE UL LISTED AS "SWITCHING BREAKERS" AT 120 V A.C. AND CARRY THE SWD MARKINGS. CIRCUIT BREAKERS SHALL BE UL LISTED. SINGLE POLE BREAKERS WITH HANDLE TIES NOT ACCEPTABLE, 4. CABLE & WIRING A. BRANCH CIRCUITS (INTERIOR) - TYPE NM OR NMC B. SERVICE ENTRANCE (DIRECT BURIAL) - TYPE USE C. FEEDERS - TYPE NNM, NMC, OR SEC D. UNDERGROUND DISTRIBUT;ON (DIRECT BURIAL) - TYPE UF - (NIC) E. CONDUCTORS TO BE COPPER F. INSULATION (600 VOLT) #10 AWG AND SMALLER - THWN/THHN, #B AWG AND LARGER - THN, THWN, XHHW (PVC FOR NM OR UF CABLES). G. NEUTRAL WIRE SHALL HAME A WHITE OUTER COVERING THROUGHOUT SYSTEM. EQUIPMENT GROUND WIRE SHALL HAVE A GREEN OUTER COVERING THROUGHOUT SYSTEM. MARK CABLES OR WIRE WITHOUT COLOR CODED JACKETS WiTH NON-FADiNG COLOR CODED TAPE AT TERMINATIONS AND OTHER ACCESSIBLE LOCATIONS. 5. RACEWAY - RACEWAY TO BE RIGID METAL CONDUIT OR SCHEDULE 40 PVC (WHERE PERMI~FED BY CODE). 6. OUTLET BOXES - OUTLET BOXES IN DRY CONCEALED LOCATIONS FOR WOOD FRAME CONSTRUCTION TO BE PVC WALL BOXES AND NORYL CEILING BOXES. IN EXPOSED LOCATIONS USE 4" SQUARE CAST ALUMINUM BOXES AND FINISHED WEATHERPROOF COVERS. 7. SWITCHES - SWITCHES, PRESSURE-SENSITIVE TYPE, 15 AMP, 120/277 VOLT, BACK AND SIDE WIRED SINGLE POLE, DOUBLE POLE, THREE-WAY AND DIMMER TYPE AS REQUIRED, DECORA TYPE. B. EQU,IPMENT WIRING - PROVIDE AND INSTALL ALL LINE VOLTAGE WIRING FOR EQUIPMENT BY OTHER TRADES. 9. DUPLEX RECEPTACLES - PROVIDE 15 AMP 125 VOLT BACK AND SIDE WIRED DUPLEX RECEPTACLES ON ALL MULTI-RECEPTACLE 15 AND 20 AMPERE CIRCUITS, PROVIDE 200 AMP 125 VOLT BACK AND SIDE WIRED DUPLEX RECEPTACLE ON ALL SINGLE RECEPTACLE 20 AMPERE CIRCUITS. GROUND FAULT CIRCUIT INTERRUPTING - 20 AMP 125 VOLT WITH INDICATOR, REPLACE ALL EXISTING OUTLETS AND PLATES. ALL DECORA TYPE. 10. PLATES - PROVIDE PLATES FOR ALL OUTLET BOXES (RECEPTACLES, SWITCH, TELEPHONE, BLANK OR COMBINATION). SMOOTH PLASTIC UREA (WHITE COLOR) UNLESS INDICATED OTHERWISE. MULTI-GANG SWITCHES, RECEPTACLES, ETC. SHALL BE IN A COMMON, ONE-PIECE PLATE. DECORA TYPE. 11. BATHROOM VENT UNiT - BROAN SENSAIRE MODEL NO. MHS120L, 120 CFM, MOTION AND HUMIDITY SENSING UNIT. PROVIDE COMPLETE WITH LIGHTING, BATTERIES, DUCT KITS AND SOFFIT/WALL VENTS. COLOR TO MATCH ROOFING. 12. LIGHTING FIXTURES - LIGHTINC FIXTURES TO BE HALO (HIGH HATS) OTHER FIXTURES AS SELECTED BY OWNER. PROVIDE ALLOWANCE OF $1000 FOR LIGHTING FIXTURES, ,3. SECURITY, CARBON MONOXIDE & FIRE PROTECTION SYSTEM. A. FIRE AND SMOKE DETECTnRS SHALL BE PROVIDED IN EACH HABITABLE SPACE, DEVICES SHALL BE DIRECT CONNECT WITH LIGHTS AND BATTERY BACK-UP. B. PROVIDE CARBON MONOXIDE DETECTION/ALARM SYSTEM AS PART OF TOTAL SYSTEM. 14. ELECTRICAL EQUIPMENT - ALL NECESSARY WIRING, SWITCHES; MOTORS, AND OTHER ELECTRICAL EQUIPMENT REQUIRED BY OTHER TRADES (WITH SPECIAL EMPHASIS ON THE HEATING-AND ',~lR CONDITIONING SYSTEM) SHALL BE PROVIDED AS NECESSARY FOR A COMPLETE OPERATIONAL SYSTEM. 15. CABLES - COORDINATE TELEPHONE AND CABLE TV JACKS, AND SECURITY CONNECTIONS AND BE SCHEDULED WITH THE OWNER AND THE LOCAL UTILITY COMPANY. AS REQUISITE FOR FINAL ACCEPTANCE AND PAYMENT, DELIVER TO OWNER TWO (2) COPIES OF A CERTIFICATE FROM UL AND LOCAL AUTHORI~'~,' SHOWING ACCEPTABILITY OF WORK DONE UNDER THIS CONTRACT. 16. POWER INTERRUPTIONS - ALL REQUIRED POWER, TELEPHONE, AND CABLE 7V INTERRUPTIONS SHALL OPERATIONAL CHECKS WITH THE RESPECTIVE COMPANIES. 17. MANUALS - CONTRACTOR TO FROVIDE ALL PRODUCT LITERATURE, WARRANTIES, AND INSTRUCTION TO OWNER. 18. CLEANUP - CONTRACTOR TO 'OLEAN UP AND DISPOSE OF DAILY, ALL HIS TRADE RELATED DEBRIS AND, WASTE MATERIALS. · /~,,~ · NOTIFY BUILDII~I AT 765-1802 ~AM TO FOLLOWIN~ I. 3. IN~U~ATI~ EXIST 4, FINAL o USE I WITH ;ERTIFICATE OF ( & WATER LINES COMPLY WITH ALL CODES OF ,CONDITIONS OF ERll CATtON OF o l CON EcTIONS gOODZONEfie ,, ~IPLY WITH CHAPTER 46 T~N CODE. SOLDER USED IN WATER SUPPLY S~TEM CANNOT EXCEED ~IO OF 1% LEAD. scale: 1 ,= 50 DATED 10-24-72. MAiN ROAD U~DF~'~ITE~S CE~TiRCATE R~'. 2 5 ALL CONSTFIUCT]ON eHALL MEET THE REQUIREMEN: ~ CODES OF NEW YORk ~ i.~, ~, EXISTING WALL TO R[EMAIN EXISTING WALL tO I~E R[EMOYED NEW INSULATED WOOD F~ME WALL NEW UNIN~ULATED WOOD FRAME WALL EXISTING DOOR[ NELU DOOR[ I / EXlCT I scale: 1" = 50' N JL 3 NOTE~ VER[IF¥ AND KE. LOCATE OIL FILL AND 'VENT PiPiNG, EXTER[IOR[ HO.~E ~ PJPI~ ~NP ELECTRIC WALL NEATE~ · ~aiN C~L 8PACE. CMU FOUNDATIC~N WALL CORE& 6" x F~UNDATION VENT5 IN GALV, AR[EA WELL5 1 El6j' DIA. ANCHOR[ BOLT5 WITH 5xSx~/l~" pLATE~ AT 4~" O~. HAX. EXIST. CRAWL ~PACE SAWCUT NEII ACCE65 OPENING AT EXISTING C. BLOCK WALl.. pAR[GE JAMB& R[E[NFORCE JO[~T. VAPOR R[ETAf~OER:--~ II'-G" ~. ~6 R[EBAR[5 AT 12" C.C, VER'I' AT NEW / EXIST. WALL INTER[bECTIONE~ TYP, LINE OF I¢" x 20" FOOTING TO ALIGN WITH EXJBTING. A, 1 scale 1/4-"= f -0" ~=XlSt. LIVING ROOM REMOYE WALL AND CLOSET DOOR[ AND FP~ME. ~ 1- EX. CL. EXISTING CEILING PAN TO ~MAIN - P~TECT D~ING CONST~CTIOH, ~ EXIST. GOLF DEN LINEN CLOSET DO0~ F~E, EX. CL. EX. LINE OF EXISTING (2.) 2xl2 FLU6H HEADER[ Af3OVE. 6UPPOI~I' AND CONNECT TO NEW (2.) I 8/4[" x II 'I/6" ML. ¢2~.) GIR[DER[ 5UPpOR[q'ED ON 4x~ POST5 AT EA. END, E×IST. hlSTf~ 15DPJ% EX. CL. R[EMOVE WALL, FLOOR[ AND CEILING GYP. E~fe, D. / FINI6HE6, ELECTR[ICAL 4 PLUMBING FIXTUI~ AND FITTING& (:::AP PLUMBING IN DR[AWL ~PACE. ' TEMPO~R[IL¥ 5UPPOR[T CEILING AND R[OO~= FRAMING, R[J~MOVE EXTERIOR ~L AND ~INDO~ BNIT. CAP HEATING PIPI~ IN C~WL bPACE. INeTALL NE~ HEADE~ALL AND CLOSET DOO~ AND F~ME. 1 A. 1 scale 1/4"=1'-0" I EXI6T. LIVING ROOM CLOSE EXISTING DOOR[ oPENING AND INSTALL NEW 4~" ~IFOLD E×I~TING CEILING FAN TO R[EMAIN - PI~2TECT OUR[lNG i CONSTR[JJCTION. ~._ / E×IST. GOLF DEN CLOOE EXISTING WALL OPENING6 WITH NEW GYP. B~. WALL6. 4'-O" HT. TILE FINISH IN LAV AR[LA, NEW MAPLE FULL ~OOD FASCIA 4 CA~INET~ AND FULL Ex. cl. l~TO ~2V-13, 22" x412b" VENTING bKYLIGHT WITH ALL6EASON-PLU5 LAMINATED,. LOW-E AR[~ON FILLED GLAZING (U=24), R[EMOTE MOTOR OpE~TO~ WITH ~IN PATTER~ GLA56 BLOCK PANEL AT JACUZZI TUB PLA'rFOR~I. 4" 6& POR[CELAIN TILE JACUZZI TUI5 PLA'M=ORM WITH R[~I6ED PANEL F~NT AND 12" HEIGHT TILE WALL 6PLASH ~UR[~OUND$ AT THR[EE 2'-O" X 4'-¢" "DECOfEA" PATTEf~ GLA66 E~LOC~ PANEL& cl. WIDEN DOOR OPENING FOR NEW b PANEL FIR DOOR[ WITH MATCHING CASING AND CHROME HARDWARE. EXIST. MSTi~ E~PPJ"I. CON6TPJJCT NEW LINEN ~HELVE~ AND )0" DP; MARBLE VANITY UNIT WITH PIVOTING 46" MIR[R[OR[5. EXISTING ~IDING INSTALL NEW WONDER[ BOAR[D UNDERLAYMENT. PR[OVIDE WR[ GYP'. I~P,D. AT ~INTEP ~U~ACE& TEM~D ~LA6~ NEC A~LE .~ ~ U~T ~IT~ ~ffE AND CAULK ~EAT, MULTI 6HO~ER ~NIT ~ 6ELECTED O~E~ -- LINE OF VENTED 2 A. 1 scale 1/¢= f -0" seal: WARD ASSOCIATES Landscape Architects, Architects, Engineers 1500 Lakeland Avenue Bohemia, N.Y. 11716 (631) 563-4800 45 West Main Street Uffle Fails, New York 11716 (315) 823-4384 project title: PROPOSED BATHROOM ADDITION for the WANKEL / GORDON RESIDENCE CUTCHOGUE, N,Y drawing title= & drawn by: checked by: date: scale: 4.2¢J.O3 A3 NOTED drawing number: 2~L o /_~ OF STATE LAW PROHIBITS ANY PERSOH FROM ALTERING ret. no.; 2005.08 LF il LINE C~= ~" HIGH ~TEPPED 6HT. MTL. FLASHING. TILE ~Uf~=ACED TUB AND MARBLE LAYATOR¥ AREA~ WITH CHERRY FINISHED II II TILE 000 3/4" DOUBLE MICROLAM RIDGE WITH 8UppORT PO~T~ DOIEN TO LOWER HEADERE,. pROVIDE GALV. JOl~T HAI'k3ER~ ~qD RII::~E ffTP~P5 AT 4 WATER ~NIELD UNDE~LA~ENT. RAFTE~ W/ R-DOC INSULATION. Pf;5~V'IDE HURRICANE TIE5 AT EA. PLATE CONNECTION. TYP. ;EDAR FASCIA - pREFINISHED WITH EDgE AND ALUM, LEADE~ AND ~UTTER TO TIE INT~ PREFINISHED CEDAR BEVEL ~IDING I.[JITH 3 I/2" CEDAR MATCH (2~x& CEA 5ILL pLATE WITH TEf~M. 6HLD, ~ILL ~EALER AND 5/&~ A~. AT 4'-~" O~. ~/ 3x3~/1~" G~. ~A~HE~ ~P. 4" P. GONG. ~LAB OVER MIL VAPOR I~ETAP~ER pOROU~ FILL. CONG. BLOCK` FOUNDATION WALL PAR~E ABOVE G~.ADE. WATEPJ~RO':~: BELO~J GRADE WITH ~ELF -ADHEREiI~k~ t~BBERIZED B[TL~INOU~ MEMBRANE. 5AIIZ:UT NEW 32" WIDE ACER55 OI=~NING INTO NELU CRAUJL 5PACE, LINE OF IO" DP. x 2~" LUIDE P. CONG. ~'~ (3BOO pGI, ) FC~::)TING ~UITH KEYWAT caNT, NOTE, FOR FASTENER SCHEDULE AND UPLIFT CONNEGTrON INFORMATION 5ER DRAWING A-~. scale 1/4"= 1'-0" ~EXI~TING TO BEMAIN OPERABLE ~KYLIGNT IIIITH LAMINATED LO~J-E INSULATED -- ~LA~$. ~EE PLAN FOR SPEC, NEW ARCHITECTU~L AE~PHALT ~,HIN~LE ROOF - 30 YEA~E WARf~'4T¥. MATCH AND ALIGN WITW EX[6TING, NE~ pREFINISHED CEDAR 8,1DING, FABCIA AND TRIM ~ITH DRIP EDUCE TO MATCH AND ALIGN WITH E×II~TING, NE~ PREFINI~HED CEDAR ,51DIN~, FAR, CIA AND TRIM WITH DRIP EDUCE TO MATCH AND ALIGN tUiTH EX[l~Tll~. CONG. BLOCK FOUNDATION WALL. / P,~R~E ABOVE GI~5,DE, WATEPJ=ROOF BI=LOW ~DE ~lTH ~ELP-ADHE~IN~ ~BBE~IZED ~ITUMINOU8 MEMBER. LINE OF IO" DP, x 20II [VIDE P, CONG. (3~OO PSI. ) FOOTING CONT. 111 11 ] V' A ][ (D N scale 1/4,"=1'-0" LINE OF E," HIGH ~TEPPED ~HT. NTh. FLAe"HING. ~ ~ CC)R-A-VENT CONSTRUCT NEW ROOF cRrGKET AND BLEND NEW ADDITION ROOF TO MATCH AND ALIGN [UITH EXISTING. LINE OF IE," WIDE LATEf~ OF ICE 6NIELD EITHER OF NE[U VALLEY TYp, NEW PREFINIGHED CEDAI~ ~IM WITH D~Ip EDgE TO MATCH AND ALIGN ~lTN EXISTINg. NEW GTOR~"1WATGH ~pRIN~LINE AND CAGEMENT UNITE~ WITH 3 I.~" AZEK, CASING. DECOR. A PATTE~ (3LASS BLOCK 51DELIGHT UNIT8 ~fTH 3 I/2" AZEK. CASING. .B, ALUMINUM FOUNDATION VENTS WITH I .~4f'__ -- -- J 5GREEN IN OALV. STEEL A~EA WELL~.-~--__~---~~'~ EL .I CONG. BLOCK. FOUNDATION WALL. PAR~E ABOVE C~-~,DE. WATERPROOF I BELOW ~R,~DE WITH 5ELF-ADHEREING I ~E~IZED ~ITUMINOU~ MEM~NE, I LINE OF IO" DP. x 20" WIDE P. CONG. (3500 PSI. ) FOOTING CONT. A.2 scale 1/4"= 1'-0" LINE OF NEW I~&:h~F CRICKET. BLEND INTO EXIGTIN~ ROOF. PULL ICE ~ WATER ~HIELD UNDEP~.ATI"IENT. EXTEND lB" PAST NEW ARCHITECTUt~,L AOPHALT 5HINt3LE ROOF - 30 YEAR WAPJ~T¥. MATCH AND ALIGN WITH EXI,~TING. caR-A-VENT NEW P~JEFINISHED GEDAf~ 51DING, PASCIA AND TRIM UJITN DRIP EDGE TO MATCH AND ALIGN WITH EXIE~TING. CONG. BLOCK. FOUNDATION WALL, PAR~E ABOVE GRADE. WATERpRoOF BELOW Gf~.ADE [UITH .~ELF-ADHEREII~ ~E~IZED ~ITUMINO~ MEM~NE. LINE OF I~" DP. x 20" WIDE P. CONG. (3EOO P51. ) FOOTING CANT. J A.2 scale 1/4"=1'-0" seal: I WARD ASSOCIATES Landscape Architects, Architects, Engineers 1500 Lakeland Avenue Bohemia, N,Y, 11716 (631) 563-4800 45 West Main Street Uffle Falls, New York 11716 (315) 823-4384 project title: PROPOSED BATHROOM ADDITION for the WANKEL / GORDON RESIDENCE CUTCHOGUE, N,Y, drawing title: & drown by: checked by: dote: scale: 4-2'=J-o~ A~ NOTED drawing number: %0% o, STATE LAW PROHISITS ANY PERSON FRON ALTERING ANYTHING ON THIS DRAWING AND/OR THE ACCOMPANYING SPECIFICATION, UNLESS IT I$ GNDER THE DIRECTION OF A LICENSED PROFESSIONAL, WHERE SUCH ALTERATIONS ARE MADE THE UCENSED PROFESSIONAL MUST SIGN, SEAL~ DATE AND DESCRfBE THE "ULL EXTENT OF THE ALTERATION ON THE :)RAWING AND/OR IN THE SPECIFICATION. ret no,: 2005.08 LF NOTE~ PROVIDE GALVANIZED ~IHP6ON 6TB~NG-TIE L~TA I~ ~TP~P tie AT TTP.(I~6~ TENBION). CONNE~TION NOT fnma. TOP PLA~E LATERAL CC~EETIGN ¢~F. CTIC~NAL VlE~J TOP PLATE LATE~AL QDiCIEGTION END VlL~J GALVANIZED SIMPSON STRONG-TIE H3 HUP-J~IC~IE TIES, IE~ GA. W/(4) ~ AT EACH JOl~T AND (4) ~ AT TOP PLATE. TTPICAL At ~ E~H J~lST / TOP PLATE C~ECTION, (465" UPLI~) NOTE= AT CORNER COLUhlN5 Pf~OVIDE ¢'=ALVANIZED ~Tt~NG TIE ECC~ COLUMN CAP C~ER UNIT~. SILL PLATE LATERAL CONNECTION ~ECTl(SqAL VIED BILL PLATE LATERAL C,~CTICN END vIEttJ NOIE~ FOE FA~IENE~ BlZE8 AND ~J~NTITE$ GALV. 51HPSON STRONG TIE MODEL M~,TA3~, 18, GA. ~TFRAp TIE~ AT I~" O.C. ~ITH (~) ~ FA~TENENE~ INTO ~g~ AND (~) ~ FA~TENE~ INTO ~AND JOISTS. (~e UPLIFT) NOTE: AT CO~E~ GALVANIZED ~T~ TIE ~DSA (~5e UPLIFT) scale 3/4" = 1'-0" UNIT DESCRIPTION ROUGH OPENING SIZE OPG. WIDTH OPG. HEIGHT EGRESS AREA UNIT AREA MANUFACTURER REMARKS CXLUI.b 5INGLE CA'Et'lENT 3'-0 I/2" ~U × E.'-O 3/E~"N. 30 I/~" Db" ~.4 ~. 14.~ ~F. ANPE~EN "BTG~"UNIT,~ J~,~ 5E511 8P~INGLINE ~INDO~ 5'-I I~''ii · x 2I-~ I/4" N. 5.1~ ~F, ANDE~EN "eTO~T~" ~]T, ~ J~, ~ / NOTE: THE PROPOSED BUILDING ADDITION REPRESENTED BY THESE PLANS HAS BEEN~ DESIGNED TO MEET THE NEW YORK STATE ENERGY CONSERVATION CONSTRUCTION CODE REQUIREMENTS VERIFIED BY THE USE Of RESCHECK WiTH THE FOLLOWH4G RESULTS: MAXIMUM UA=48 / PROVIDED UA=45 MAX. CODE GLAZING U=.57 / GLAZING U=.S4 TABLE 502.2.4(4 ) 18 % WINDOW AREA HEATING DEGREE DAYS: 5750 GLAZING U FACTOR: CEILING R-VALUE: CODE: .37 CODE: .38 ACTUAL: .54 ACTUAL: .50 EXTERIOR WALL R-VALUE: FLOOR R-VALUE: CODE: 19 CODE: 19 ACTUAL: 19 ACTUAL: SO SLAB PERIMETER R-VALUE / DEPTH: BASEMENT WALL R-VALUE: CODE: 9. 2~T. CODE: 10 ACTUAL: N/A ACTUAL: N/A CRAWL SPACE WALL R-VALUE: CODE: 19 ACTUAL: N/A GROUND SNOW LOAD: 45 PSt (F$01.2(5)) FLOOR LIVE LOAD: 40 PSF (BEDROOMS, BECKS AND STAIRS) (R301.4) $0 PSF (OTHER THAN SLEEPING) 60 PSF (EXTERIOR BALCONIES) 20 PSF (ATTICS WITH STORAGE) / 10 PSF (ATTICS WITHOUT STORAGE) $0 PSF (OTHER THAN SLEEPING) ROOF LIVE LOAD: 16 PSF MIN. (R$01.5) BASIC WIND SPEED: 120 MPH (F501.2(4)) SEISMIC DESIGN CATEGORY: C ( AS DETERUlNED BY CODE OFFICIAL) (P301.2(2)) WEATHERING PROBABILITY: TERMITE PROBABILITY: DECAY PROBABILITY: WINTER DRY-BULB TEk!P: DECAY PROBABILITY: SEVERE MODERATE TO HEAVY SLIGHT TO MODERATE 11 DEGREES f SLIGHT TO MODERATE (R501.2($)) (R501.2(6)) (RS01.2(7)) (TAB, Nl101.2) (R501.2(7)) CRAWL 5PACE N.T.S. SCHiSD'L FOR S* .UCTLTRAL IVflSlVflt] ,S ' able 3.1) 2" PLA~ GENERAL NOTES I. CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AT THE SITE PRIOR TO COMMENCING CONSTRUCTION. 2. DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS SUPERSEDE SCALED DIMENSIONS. 3. ALL WORK SHALL DONFORM TO THE RESIDENTIAL CODE AND THE ENERGY CONSERVATION CONSTRUCTION CODE OF NEW YORK STATE, THE NATIONAL ELECTRIC CODE AND THOSE OF THE LOCAL JURISTICTION. 4. ALL FOOTINGS SHALL BEAR ON UNDISTURBED SOIL HAVING A REARING CAPAClSY OF AT LEAST 1 TON PER SQUARE FOOT AND SHALL HAVE A MINIMUM COVER OF S FEET BELOW GRADE. 5. STRUCTURAL LUMBER SHALL BE DOUG. FIR ~1, Fb = 1000 psL (baae) E=I,7OO,OOD PSIj NONDEARING LUMBER SHALL BE HEM-FIRi~2 WITH Fb = 850 psi. (base), E = 1,500,000 psi. 6. STRUCTURAL STEEL SHALL BE ASTM A-572, DETAILED, FABRICATED AND ERECTED IN ACCORDANCE WITH THE AISC. 7, ALL HEADERS SHALL BE SUPPORTED ON 4x4 POSTS MIN. UNLESS NOTED OTHERWISE ON THE DRAWINGS. 8. PROVIDE DOUBLE HEADEBS AND TRIMMERS AT ALL FLOOR, STAIR AND ROOF OPENINGS AND UNDER ALL POSTS AND PARTITIONS RUNNING PARALLEL TO SAME. S. ALL HEADERS LESS THAN 5'-0" SPAN SHALL BE (2) 2xlg UNLESS NOTED OTHERWISE. 1D. PROVIDE SOLID OR 5/4" x 5" CROSS BRIDGING AT 5'-0" MAX. 11. PROVIDE OALV. FRAMING CONNECTORS AT ALL BUTT STRUCTURAL CONNECTIONS AND H8 HURRICANE TIES AT TOP PLATE TO ROOF FRAMING CONNECTIONS. 12. PROVIDE HARD WIRED SMOKE DETECTORS AT EACH FLOOR LEVEL AND IN ALL BEDROOMS, AND AS REQUIRED BY CODE AND THE LOCAL AUTHORITIES. PROVIDE A CARBON MONOXIDE DETECTOR AT EACH FLOOR LEVEL. 15. CONTRACTOR SHALL DO ALL PATCHING REQUIRED DUE TO HEW WORK AND / OR REMOVAL OF EXISTING. ALL PATCHING SHALL MEET FLUSH AND MATCH EXISTING CONSTBUCTION UNLESS NOTED OTHERWISE. 14. UNLESS NOTED DTHERWlSE, ALL WINDOW DESIGNATIONS SHOWN ARE THOSE OF THE ANDERSEN CORPORATION. UNitS TO HAVE WIND BORNE DEBRIS RESISTANT GLAZING "STORMWATCH" (MISSLS D-ASTM E 1996)) WITH LOW E COATING, EXTENSION JAMBS~ SCREENS. GRILLES AS SHOWN ON DRAWINGS. 15, CCA OR ACG TRTD. WOOD SILLS SHALL BE (2) 2x6 WITH 1/2" DIA. ANCHOR BOLTS SPACED 4'-0" O.C. MAX. PROVIDE 2 BOLTS WITH 5" SQ. X 3/16" WASHERS P£R SILL SECTION MINIMUM. pLACE BOLTS WITHIN 1'-0" OF ALL CORNERS. INSTALL OVER SILL SEALER AND TERMITE SHIELD (TYPICAL). 16. CONCRETE SHALL HAVE A MINtMUM 28 DAY COMPRESSIVE STRENGTH OF S000 PSI (5500 PSI FOR EXTERIOR EXPOSURES). seal: WARD ASSOCIATES Landscape Architect~, Architects, Engineers 15a0 Lakeland Avenue Bohemia, N,Y, 11716 (681) ~ 45 West Main Street Uffle Falls, New York 11716 (315) 823-4384 project title: PROPOSED BATHROOM EXTENSION for the WANKEL / GORDON RESIDENCE CUTCH~UE, N,Y, drawing title: gC ]I-III]lll>llIILIlig, & drawn by: Ichecked by: LMF J ~ date: I scale: 4-2c3'0'5 IA5 NOTED drc~vlng number: o (~/~) OF STATE LAW PROHIBITS ANY PERSOR FROM ALTERHG ANYTHING ON THIS DRAWING AND/OR THE ACCOMPANYING SPECIFIOATION, UNLESS IT IS UNDER THE DIRECTION OF A LICENSED PROFESSIONAL, WHERE SUCH ALTERATIONS ARE MADE THE MO£NSED PROFESSIONAL MUST SIGN, SEAL, DATE AND DESCRIBE FULL EXTENT OF THE ALTERATION ON DRAWING AND/OR IN THE mf. no.: 2005,15LF