Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
1000-15.-9-8.1
OFFICE LOCATION: Town Hall Annex 54375 State Route 25 (cot. Ma/n Rd. & Youngs Ave.) Southold, NY 11971 MAILING ADDRESS: P.O. Box 1179 Southold, NY 11971 Telephone: 631 765-1938 Fax: 631 765-3136 LOCAL WATERFRONT REVITALIZATION PROGRAM TOWN OF SOUTHOLD MEMORANDUM To: Jim King, President Town of Southold Board of Trustees From: Mark Terry, Principal Planner LWRP Coordinator Date: October 12, 2012 Re: Wetland Permit for NEW CINGULAR WIRELESS PCS, LLC SCTM# 15-9-8.1 R6, Nielsen, Huber & Coughlin, LLP on behalf of NEW CINGULAR WIRELESS PCS, LLC requests a Wetland Permit to erect a 70' stealth monopole, install public utility wireless telecommunications antennas therein, and install related equipment and landscaping on the ground. Located: Orient By The Sea Marina, 40200 Main Road, Orient. SCTM# 15-9-8.1 The proposed action has been reviewed to Chapter 268, Waterfront Consistency Review of the Town of Southold Town Code and the Local Waterfront Revitalization Program (LWRP) Policy Standards. Based upon the information provided on the LWRP Consistency Assessment Form submitted to this department, as well as the records available to me, it is my recommendation that the proposed action is CONSISTENT with the Policy Standards and therefore is CONSISTENT with the LWRP. Pursuant to Chapter 268, the Board of Trustees shall consider this recommendation in preparing its wdtten determination regarding the consistency of the proposed action. Cc: Lori Hulse, Assistant Town Attorney Town of Southold LWRP CONSISTENCY ASSESSMENT FORM A. INSTRUCTIONS All applicants for permits* including Town of Southold agencies, shall complete this CCAF for proposed actions that are subject to the Town of Southold Waterfront Consistency Review Law; This assessment is intended to supplement other information used by a Town of Southold agency in making a determination of consistency. *Except minor exempt actions including Building Permits and other ministerial permits not located within the Coastal Erosion Hazard Area. Before answering the questions in Section C, the preparer of this form should review the exempt minor action list, policies and explanations of each policy contained in the Town of Southold Local Waterfront Revitalization Program. A proposed action will be evaluated as to its significant beneficial and adverse effects upon the coastal area (which includes all of Southold Town). If any question in Section C on this form is answered "yes", then the proposed action may affect the achievement of the LWRP policy standards and conditions contained in the consistency review law. Thus, the action should be analyzed in more detail and, if necessary, modified prior to making a determination that it is consistent to the maximum extent practicable with the LWRP policy standards and conditions. If an action cannot be certified as consistent with the LWRP policy standards and conditions, it shall not be undertaken. A copy of the LWRP is available in the following places: o0~-a~of Southold's website (southoldtown. northfork.net), the Board of Trustee~/Ohli0~ tl~ l~lY~at'maemt, all local libraries and the Town Clerk's office. i, ; SEP 2120 I/ " B. DESCRIPTION OF SITE AND PROPOSED ACTION SCTM# :1.5 - 9 - 8.1 .... The Application has been submitted to (check appropriate response): Town,o.rd [] Pl.n. g,ep,. Category of Town of Southold agency action (check appropriate response): (a) Action undertaken directly by Town agency (e.g. capital construction, planning activity, agency regulation, land mmsaction) (b) Financial assistance (e.g. grant, loan, subsidy) (c) Permit, approval, license, certification: Nature and extent 0f action: Un-manned Public Utility Wireless Communication Services Facility consistin~ of panel antennas mounted within a 70' RF-transparent monopole, elevated equipment platform and trenched conduit. Locationofaction:40200 Main Rd., Orient Point, New York 11957 Site acreage[ 4.55 Present land u~: un-manned public utility wireless communications facility Prosent zoning classification: Marine II (MII) District If an application for the proposed action has been filed with the Town of Southold agency, the following information shall be provided: (a) Name ofapplicant: New Cingular Wireless PCS, LLC ~) Mailingaddross: 1444 E Jericho Tpke. Hu-ntinqton, NY 11743 (c) Telephonenamber:ArcaCode( ) Cingular (516) 567-8478 (d) Application number, if any:. Will the action be directly undertaken, require funding or approval by a state or federal agency? Yes [~ No ~ If yes, which state or federal agency.9. FCC DEVELOPED COAST POLICY Policy 1. Foster a pattern of development in the Town of Southold that enhances community character, preserves open space, makes efficient use of infrastructure, makes beneficial use of a coastal location, and minimizes adverse effects of development. See LWRP Section HI - Policies; Page 2 for evaluation Criteria. [] Yes ~] No [] Not Applicable Refer to attachment Attach additional sheets if necessary Policy 2. Protect and preserve historic and archaeological resources of the Town of Southold. See LWRP Section HI - Policies Pages 3 through 6 for evaluation criteria ~ Yes [] No [] Not Applicable Refer to attachment Attach additional sheets if necessary Policy 3. Enhance visual quality and protect scenic resources throughout the Town of Southold. See LWRP Section IH - Policies Pages 6 through 7 for evaluation criteria ~ Yes [] No [] Not Applicable Attach additional sheets if necessary NATURAL COAST POLICIES Policy 4, Minimize loss of life, structures, and natural resources from flooding and erosion. See LWRP Section IH - Policies Pages 8 through 16 for evaluation criteria ~ Yes [] No [] Not Applicable Refer to attachment Attach additional sheets if necessary Policy 5. Protect and improve water quality and supply in the Town of Southold. See LWRP Section HI - Policies Pages 16 through 21 for evaluation criteria [] Yes ~-~ No [] Not Applicable Attach additional sheets if necessary Policy 6. Protect and restore the quality and function of the Town of Southold ecosystems including Significant Coastal Fish and Wildlife Habitats and wetlands. See LWRP Section HI - Policies; Pages 22 through 32 for evaluation criteria. [] Yes ~-~ No ~-~ Not Applicable Refer to attachments Attach additional sheets if necessary Policy 7. Protect and improve air quality in the Town of Southold. See LWRP Section III - Policies Pages 32 through 34 for evaluation criteria. ~ Yes ~-~ No [] Not Applicable Refer to attachment Attach additional sheets if necessary Policy 8. Minimize environmental degradation in Town of Southold from solid waste and hazardous substances and wastes. See LWRP Section m - Policies; Pages 34 through 38 for eValuation criteria. [] yes [] No [] Not Applicable Refer to attachment PUBLIC COAST POLICIES Policy 9. Provide for public access to, and recreational use of, coastal waters, public lands, and public resources of the Town of Southold. See LWRP Section IH - Policies; Pages 38 through 46 for evaluation criteria. [-~ Yes~ No [] Not Applicable Attach additional sheets if necessary WORKING COAST POLICIES Policy 10. Protect Southold's water-dependent uses and promote siting of new water-dependent uses in suitable locations. See LWRP Section III - Policies; Pages 47 through 56 for evaluation criteria. ~-~ Yes [--] N~t Appii~ Atlach additional sheets if necessary Policy 11. Promote sustainable use of living marine resources in Long Island Sound, the Peconic Estuary and Town waters. See LWRP Section III - Policies; Pages 57 through 62 for evaluation criteria. ~-~ Yes ~-] No ~ Not Applicable Attach additional sheets if necessary Policy 12. Protect agricultural lands in the Town of Southold. See LWRP Section 11I - Policies; Pages 62 through 65 for evaluation criteria. ~] Yes ~ No ~-~ Not Applicable Refer to attachment Attach additional sheets if necessary Policy 13. Promote appropriate use and development of energy and mineral resources. See LWRP Section III - Policies; Pages 65 through 68 for evaluation criteria. [] Yes [~ No ~ Not Applicable Created on 5/25/05 11:20 AM Town of Southold LWRP CONSISTENCY ASSESSMENT FORM DESCRIPTION OF PROPOSED FACILITY: Construct a new 70-foot agl RF-compatible monopole with antennas installed inside within a fenced compound to accommodate equipment for New Cingular Wireless PCS, LLC (William F. Collins, AIA drawings last revised 8/03/12, attached). The proposed public utility wireless communication services facility will be located near the western boundary of the Orient by the Sea restauran~ DEVELOPED COAST POLICY Policy I. Foster a pattern of development in the Town of Southold that enhances community character, preserves open space, makes efficient use of infrastructure, makes beneficial use of a coastal location, and minimizes adverse effects of development. The adverse effects of development are mitigated by siting the proposed telecommunications Facility in the only commercially zoned (M-II) land in this part of Reach 5. The proposed location is adjacent to the Cross Sound Ferry terminal and the Plum Island Animal Disease Center (PIADC) USDA ferry terminal. The existing eight-foot high chain link fencing topped with barbed wire, and the tall lighting stanchions at the PIADC are not positive enhancements to the scenic qualities of the SR 25s byway. The use of a 70' tall RF-compatibie concealment monopole with antennas mounted inside, partially screened by the planting of new juniper trees, and the siting of the Facility within a commercially zoned area, will preserve open space, make efficient use of existing infrastructure and minimize the adverse effects of development. In addition, by siting the proposed un-manned telecommunications Facility is a commercially developed area, the proposed project will not add to the increasing development pressure on the Town's extensive agricultural areas and on the waterfront that threatens the rural character of the community and its natural resources. In addition, verbal discussions with government personnel from the Town of Southold conducted in May 2006, and a review of public hearing transcripts indicate that public opposition to the construction of telecommunication towers is generally limited to residential areas, and not the Mil zone for the proposed Facility. These objections pertain mainly to aesthetics from obstructed views, and perceived declines in property value from the presence of telecommunication towers (Environmental Assessment Report, Orient Point Telecom, Site L1-1059, Block 9, Lot 8, Town of Southold, Suffolk County, NY, prepared by AMEC Earth and Environmental, Inc., on behalf of GeoTrans, Inc, dated June 9, 2006). With regards to community considerations, Based on the above, the proposed undertaking meets the longstanding planning goals of the Town of Southold which are to "reflect the interest in preserving and enhandng the natural and built environment and providing opportun~es for a level of growth and expansion of the economic base that is compatible w~ the existing scale of development, availability of water, existJng sensitive environment of the Town and its historic heritage." Policy 2. Protect and preserve historic and archaeological resources of the Town of Southold. On May 5, 2009, Richard Grubb and Associates, Inc. completed a Section 106 consultation package and submitted a request for comments in which they determined that "No Historic Properties" were identified at the location of the proposed undertaking (then a 100' monopole). SHPO policy states: "If the SHPO does not provide written notice to the Applicant that it agrees or disagrees with the Applicant's determination of no Historic Proper~es affected within 30 days following receipt of a complete Submission Packet, it is deemed that no Historic Properties exist within the APE or the Undertaking will have no effect on Historic Properties. The Se~on 106 process is then complete and the Applicant may proceed with the project, unless further processing for reasons other than Section 106 is required." No 'response from SHPO was received within the following 30-day comment period. As such, concurrence with the project's determination of "No Historic Properties" was assumed. EBI submitted an addendum to the original submittal that reflects the design change to an 80' monopole on August 28, 2009. The original determination of "No Historic Properties" remained the same. In addition, Sara Ayers-Rigsby, MA, RPA, Project Archaeologist with EBI Consulting, reviewed the previous archaeological assessment, new site plans, and NYSHPO correspondence for the proposed telecommunications facility at the above-referenced location. It is the professional opinion of Ms. Ayers-Rigsby that the shift in the tower position to the north and expansion of the equipment compound from the original I I' x 26' (3.6 x 7.9m) lease area to 12'8" x 29' I 0" (3.9 x 9.1 m) does not significantly alter the archaeological findings of Richard Grubb and Associates, Inc., who concluded in April 2006: "The APE-Direct Effects lies in an area of moderate to high potential for prehistoric and Iow potential for historic resources. However, based on the prior ground disturbances caused by extensive grading and infilling related to the construction of the existing marina, parking lot, wooden fence, and the installation of the existing utilities, it is highly unlikely that significant archaeological resources exist in the APE- Direct Effects. AS such, Richard Grubb & Associated recommends no further archaeological survey." The drawings have since been revised again (dated 8-03-12) to shorten the proposed tower height to 70 feet above grade, to move the AT&T equipment pad to the north side of the tower, and to to increase the cabinetry height to 12.5 feet agl. Based on the above, the proposed undertaking will protect and preserve historic and archaeological resources of the Town of Southold. Policy 3. Enhance visual quality and protect scenic resources throughout the Tow~ ot' Southold. See LWRP Section III - Policies Pages 6 through 7 for evaluation criteria Minimize introduction of structural design components (including utility lines, lighting, signage and fencing) which would be discordant with existing natural scenic components and character. The proposed undertaking is located in a commercially-zoned area and only commercially zoned (M-II) land in this part of Reach 5. The proposed location is adjacent to the Cross Sound Ferry terminal and the PIADC USDA fern/ terminal. The existing eight-foot high chain link fencing topped with barbed wire, and the tall lighting stanchions at the PIADC already introduce structures discordant with the neighboring scenic character. In order to mitigate discordant elements introduced by a new telecommunic~ons facility, a 70' tall RF-comp~ble concealment monopole ~ antennas mounted inside is proposed, which will reduce its visual footprint In addition, landscaping, screening and fencing will be designed in accordance with the Town of Southold Wireless Code. B. Restore deteriorated and remove degraded visual components. N/A Screen components of development which detract from visual quality. Landscaping, screening and fencing will be designed in accordance with the Town of Southold Wireless Cods Use appropriate siting, scales, forms, and materials to ensure that structures are compatible with and add interest to existing scenic components. ]'he proposed undertak/ng is located in a commerdally-zoned area and only commerdally zoned (M-II) land in this part of Reach 5. The use of a 70' tall RF-compatible concealment monopole with antennas mounted inside will m~gate issues of scale and form when viewed from neighboring non-commercially-zoned land. Ee Preserve existing vegetation and establish new indigenous vegetation to enhance scenic quality:. I. Preserve existing vegetation which contributes to the scenic quality of the landscape. 2. Allow for selective clearing of vegetation to provide public views without impairing values associated with the affected vegetation. 3. Restore historic or important designed landscapes to preserve intended or designed aesthetic values. 4. Restore or add indigenous vegetative cover that presents a natural appearance. The proposed undertaking will not d/sturb exi~ng vegetation and new vegetation will be planted in accordance with Town of Southold Wireless Code. F. Improve the visual quality associated with hamlet areas. N/A G. Improve the visual quality of historic maritime areas. N/A Protect the visual interest provided by active water-dependent uses. The proposed telecommunications facility in the only commercially zoned (M-II) land in this part of Reach 5. The proposed location is adjacent to the Cross Sound Ferry terminal and the PIADC USDA ferry terminal. Visual interest provided by active water- dependent uses will not be adversely impacted. Anticipate and prevent impairment of dynamic landscape elements that contribute to ephemeral visual qualities. The proposed telecommunications facility in the only commercially zoned (M-II) land in this part of Reach 5. Dynamic landscape elements that contribute to ephemeral visual qualities will not be affected. Protect visual quality associated with public lands, including public transportation routes, public parks and public trust lands and waters. Siting the proposed telecommunications facility in the only commercially zoned (M-II) land in this part of Reach 5, and limiting the height to 70' with antennas placed inside the stealth pole, will mitigate impacts to the visual quality of the area, including Orient Point County Park to the easr~ and Orient Beach State Park to the west. The construction of an 70' stealth pole, while taller than existing structures, will not be incompatible with the adjacent commercial facilities (Cross Sound Ferry terminal and the PIADC USDA ferry terminal). Orient Point State Park is the most intensely used, publicly-owned, scenic resource in Southold Town. Due to its geographic location, this park provides uninterrupted panoramic vistas of the open waters of Gardiners Bay, and with views of Gardiners Island, Shelter Island and Montauk in the distance. The proposed undertaking will not interrupt these vistas. The North Fork Seaview Trail follows SR 25 for its entire length within Reach 5. The easternmost terminus of SR 25 runs alongside the staging area of the ferry dock. Both the Cross Sound Ferry terminal and the PIADC USDA ferry terminal already negatively affect the scenic resources of the State-designated Scenic byway on which they front due to the existence of extensive paving and lack of landscapin~ is the primary cause. The introduction of the proposed stealth monopole at the proposed location is the best option to minimize visual intrusions to the area~ I. Limit water surface coverage or intrusion to the minimum amount necessary. N/A 2. Limit alteration of shoreline elements which contribute to scenic quality. N/A Protect visual quality associated with agricultural land, open space and natural resources. Siting the proposed telecommunications facility in the only commercially zoned (Fl-II) land in this part of Reach 5, and limiting the height to 70' with antennas placed inside the stealth pole, will mitigate impacts to the visual quality of the area. The visual quality of agricultural land, open space and natural resources will be protected. I. Maintain or restore original landforms except where altered landforms provide useful screening or contribute to scenic quality. Existing landforms will not be altered. 2. Group or orient structures during site design to preserve open space and provide visual organization. All supporting structures will be located within a proposed equipment compound screened by new plantings. 3. Avoid structures or activities which introduce visual interruptions to natural landscapes including: a) introduction of intrusive artificial light sources; Intrusive artificial lighting is not proposed. b) fragmentation of and structural intrusion into open space areas; open space areas will not be affected c) changes to the continuity and configuration of natural shorelines and associated vegetation The natural shoreline will not be affected Policy 4. Policy S. Policy 6. Policy 7. Policy 8. Minimize loss of life, structures, and natural resources from flooding and erosion. See LWRP Section III - Policies Pages 8 through 16 for evaluation criteria The Federal Emergency Management Agency (FI:MA) Flood Insurance Rate Map (FIRM) for the site area indicates that the property and the surrounding areas are located within Zone AF~ which is defined as "Special Flood Hazard Areas Inundated by 100-Year Flood", with a base flood elevation of 8'. The proposed equipment platforms will be raised to mitigate negative impacts to the flood storage capacity of the area. Protect and improve water quality and supply in the Town of Southold. N/A Protect and restore the quality and function of t~e Town of Southold ecosystems including Significant Coastal Fish and Wildlife Habitats and wetlands. The proposed undertaking is sited on commercially-developed land and will not impact the quality and function of the Town of Southold ecosystems including Significant Coastal Fish and Wildlife Habitats and wetlands. In a response letter dated November 21, 2005 to GeoTrans, the United States Fish and Wildlife Service reported that except for Occasional transient individuals, no Federally-listed or proposed endangered or threatened species under their jurisdiction are known to exist within the project impact area. In addition, no habitat in the project impact area is currently designated or proposed "critical habitat" in accordance with provisions of the Endangered Species Act (ESA) (87 Stat. 884, as amended; 16 U.S.C. 1531 et seq.). According to the "Guidelines for Consultation with NY Natural Heritage regarding Proposed Collocations of Telecommunication Facilities on Existing Towers and Buildings", issued by the New York State Department of Environmental Conservation (NYSDEC)- Division of Fish, Wildlife & Marine Resources, dated May 2009, for communications facilities projects that involve "New or existing towers, antennae, and associated equipment installed at a location currendy wholly occupied by lawn, pavement and/or gravel," -,.he NYSDEC does not "have any records of rare species or significant natural communities which will be of concern in relation to the proposed projects." Inasmuch as the proposed project is located on land previously disturbed, rare species or significant natural communities will not be affected by development of the proposed undertaking. Protect and improve air quality in the Town of Southold. The proposed undertaking will not generate air pollution. Minimize environmental degradation in Town of Southold from solid waste and hazardous substances and wastes. The proposed undertaking is un-manned and will not generate solid waste and hazardous substances and wastes. Policy 9. Provide for public access to, and recreational use of, coastal waters, public lands, and public resources of the Town of Southold. N/A Policy 10. Protect Southold's water-dependent uses and promote siting of new water- dependent uses in suitable locations. N/A Policy I I. Promote sustainable use of living marine resources in Long Island Sound, the Peconic Estuary and Town waters. Policy 12. Protect agricultural lands in the Town of Southold. The proposed undertaking will be located in a commercially zoned land, thereby protecting agricultural land. Policy 13. Promote appropriate use and development of energy and mineral resources, N/A at&t SITE NUMBER: NYCENY1059 SITE NAME: ORIENT BY THE SEA RESTAURANT DRAWING INDEX T-1 TITLE SHEET A-1 SFFE PLAN A-2 PARTIAL SITE PLAN A-3 EAST ELEVATION ARCHITECTURAL DETAILS AND GENERAL NOTES TELCO, ELECTRIC. GROUNDING PLAN AND DETAILS DIRECTIONS: VICINITY MAP ORIENT BY THE SEA RESTAURANT NYCENY1059 / L1-1059 at&t PROJECT INFORMATION SITE QUALIFICATION PARTICIPANTS SI'I I~ DATA ~1~ .SITE pLAN ORIENT BY THE SEA RESTAURANT NYCENY1059 / Uo1059 NYZ320 t,r ~ at&t~ PARTIAL SITE pLAN ORIENT BY THE SEA RESTAURANT NYCENY10S9 / U-1859 I~ ~t&t I" I ~ ~ST EL~ATION i ORIENT BY THE SEA RESTAURANT NYCENY1059 / U-1059 NYZ320 ~ at&t ~,E~r~ ~!L @ TYPICAL UTILITY TRENCH I ~ ~"ff_~-~-¢"~_ ~P. EL~ATED ICE BRIDGE DETAIL I DETAIL @ UNDERGROUND ~.D,U~.IT STUB-UP CABLE SUPPORT ~,FOR EQUIPMENT CABINETS ~ at&~t ~11~ PURCELL EQUIPMENT CABINET FIBER AND POWER 1~/0 DISTRIBUTION BOX DC2-48-60-O-9E I ~ REMOTE RADIO HEAO (RRH) RACK DETAIL ORIENT BY THE SEA RESTAURANT NYCENY1059 / U-1659 N~7320 at&t ALCATEL-LUCENT 9442 REMOTE RADIO HEAD (RRH) DETAIL <,~PICAL ANTENNA MOUNTING DETAIL NOT USED 100 2.5 TYP. UMTS/LTE ORIENT BY THE SEA RESTAURANT NYCENY10S9 / Ll-1059 NY7320 I ANDREW TOWER MAST AMPUFIER ~ ~..~I:MA) ETD819HS12UB DETAIL E911 / LTE GPS ANTENNA ~APIPE AND L- RRACKET MOUNT at&t 6 )4~B?~T. AIL@ WOVEN WIRE FENCE DETAIL DETAIL @ WOVEN ,~WIR I~E~CE DETAIL DETAIL @ WOVEN WIRE GATE DETAIL ~1/1~, ~L:AN? S~CHEDULE DETAIL .~1 ~_STRUCTURAL FRAMING pLAN ~,~ TYP. HANDRAIL MOUNTING DETAIL m,s m[~ ~s .' x ,r .E~E. ~ PIER D~AIL ORIENT ~ THE S~ RESTAU~NT ~ ~ NYCE~1059 / LI-'059 at&t HANDRAIL ELEVATION ~ EQ?PMENT pLATFORM ELECTRICAL RISER DIAGRAM ~ PA_~EL SCHEDULE ~ ELE~CTRICAL SYMBOLS AND ABBREVATIONS 50~ ...... ~.~i~_66 BLOCK ALARM ASSIGNMENTS (24VDC) ORIENT BY THE SEA RESTAURANT I ~at&~ NYCENY1059 / L1-1059 D~TAIL A TERMINAL I~LOCK WIRING AC SINGLE- LINE DIAGRAM FOR ARGUS TE41 POWER PLANT ~ atilt SYSTEM DIAGRAM, TOWER SITE ORIENT BY THE SEA RESTAURANT H¥CENT1059 / LI-105g N~7320 at&t ( I I I I I I I I I I I I I I I I I I WIRING DIAGRAM, OUTDOOR AT ~¢ ~/~C ~ ~0~ BASE BAND AND RRHs ON GROUND, DC/DC CONVERTER ORIENT BY THE SEA RESTAURANT at& {~..9~?'¥E,T GROU,m,G "' I ORIENT BY THE SEA RESTAURANT NYCEHYIQ59 I U-1059 NY7320 ...... J ;2 AWG SOLO. GROUND RING, 'ryr ~ TYP. GROUNDING SCHEMATIC V //~ GRO~N? ROD TEST WELL ~_'I~_P.~GROUND BAR CONNECTION DETAIL CONDUIT BOND / GROUND BUSHING DETAIL i 1/1/i~>INSTALLATION OF GROUND WIRE TO COAX CAB LE GROUND RAR CONNECTION OF CABLE GROUND KIT TO ANTENNA CABLE ORIENT BY THE SEA RESTAU.ANT ~ at&t NYCENYI059 / ~GB .E~E.E.C~- G.GU.D ~^R DETAIL SITE NAME: ORIENT BY THE SEA RESTAURANT Southhc!~ ~'cwS Bo~r~ of 7r~stee~ DRAWING INDEX R~, DIREOTIONS: PROJECT INFORMATION t-1 TITLE SHEET 9 MID.ND A~ (NO~H-W[~) T~[ ~MP (RIG~) 0~0 SR-17 SCOPEOFWORK: ~ UN~NNED T[LECOMMUNI~qON~ FACI~ INCLUDING A-1 SITE ~N 9 TAKE ~MP (L[~) O~O 1-95 ~PRESS LN [N~ JERS~ TPKE] EL~A~D ~E[L EQUIPME~ P~ORM AND RE~TED ~EN~ A-2 PARTIAL SITE P~N 9 MERGE O~0 1-95 [N~ JE~ TPKE] KEEP ~G~ ONTO 1-295 [CROSS BRONX ~ E~] MOU~D INSIDE N~ RF ~$P~E~ MONOPO~. T~[ ~MP (RIG~ ONTO CROSS IS~ND PKY AT ~ ~0E, KEEP RIG~ O~O ~MP (0.4 MI) A-3 EAST ELEVATION 9 TAKE ~MP (LE~) O~0 I-~95 [LONG IS~ND EX~] AT ~ 7], TURN OFF 0~0 ~P S~EADDRESS: 40200 ~[N RD. (~.k.o.S.R. 25) A-4 ARCHITECTURAL DETAI~ AND GENERAL NOTES 9 KEEP L[~ TO ~AY ON ~MP B~R RIGHT (~T) O~O CR-58 [OLD COU~Y RD] ORIE~ ~1~, N.% 11957 KEEP STRAIGHT 0~0 SR-25 [MAIN RD] TURN ~ (NO~H-W[~ 0~0 L~E LN A-5 ~ABINET DETAILS 9 TURN RIGHT (NO~H-~ST) ONTO CR-~ [MIDD~ RD] TURN L[~ (NORTH) 0~0 CR-~ [~IN RD] PROPE~OWNER: M.O.H. E~RPRISES, INC. A~ ANTENNA MOUNTING DETAILS 9 KEEP ~IGHT 0~0 SR-25 [M~N RD] ARR~E AT ~IN RD. ORIE~ POI~ ~ 11957 A-/ ARCHITECTURAL DETAI~ 9 VICINI~ MAP CONTAC PERSON; BOB ~E (611) ]2~-2~2~ A-8 STRUCTURAL FRAMING P~N, NOTES AND DETAILS 9 E-1 ELECTRIOAL RISER DIAGRAM AND NOTES 9 A~UC~NT: N~ CINGU~ WIRELESS PCS, LLC E-2 ELECTRICAL DETAILS, SYMBOLS AND ABBREVIATIONS 9 P~US. ~ 07652 E-sE'4WIRINGDc/DcSYSTEM DIAGRAM, TOWER SITE WITH OUT.OR BASE BAND RRHs ON GROUNDcoNVERTERDiAGRAM, OUTDOOR BASE BAND RRHs ON GROUND 99 ~ ~'+--~ ---- '~~ JURISDI~.N=EL~ATION: TOWNS'-~ AMSLoF SO'HO' T~I.D. NUMBER: BLK: 9 LOT: 8.1 SEC: 15 E'6 TELCO, ELECTRIC, GROUNDING P~N AND DETAILS 9 ~ ~. ~~ ~ / ~ ~-- ZOmNG D.S~,CT: ZONE: ~RINE -BUI~ING O~IC~LS AND CODE ADMINIST~ON (BO~) -AMERICAN ~DARDS ~SOC~TION (~) ~ RF VI~OR~ BREN~ SHORE 2 SHORE (631) 807-78~6 -BUI~ING CODE OF THE ~ATE OF N~ YORK -UNDERWREE~ ~O~TORiES UL ~ -~TIONAL ELECTRIC CODE (NEC) -NA~O~ ELEC~IC ~UFACTU~ ~SOClATION (NE~) ~ ~ ~ ~ ~ CON S~HED HU~N BEC~EL TE~COMMUNI~TIONS (978) 239-5328 NEW AT&T ELECTRIC CONDUITS TRENCHED EXISTING OVERFHREADM UNDERGROUND FROM NEW AT&T ELECTRICAL UTILI]h' LINES O ME-fER AND DISCONNECT SUPPORT RACK TO NEW UTILI~¢ POLE ELEVATED EQUIPMENT PLATFORM. SEE 1/A-4 FOR TRENCHED UNDERGROUND FROM PROPERTY LINE TYP~ NEW MESA SPAN CABINET AT " so .wE T CORNER oE ~lEw EX ST NO TRANSFORMER, W~DE ~TERN RED CEDARS e P~TFORM, SEE 1/A-2 FOR N~ AT~T 70'-~ HIGH RF ~'/~ ~ ~ ORIENT BY THE S~ RESTAURANT ~ . . A -*,- ......... I~ B B , ........................ ORIENT POINT NY 1 957 SITE DATA --A--A-- ANTENNA CABLE DRAWING DEPICTS THE INSTALLATION OF NEW ANTENNAS, THE CONTRACTOR IS TO REGRADE THE AT&T ANY EXISTING TREES, UNDERLYING VEGETATION, SEE SHEET A-4 FOR ADDITIONAL 1. ALL STORM WATER RUN-OFF GENERATED BY THE PROPOSED CABLING ETC. THAT ARE TO BE MOUNTED WITHIN THE NEW EQUIPMENT COMPOUND AREA FO A LEVEL TRNLERS AND BOATS IN AREA OF NEW CONSTRUCTION DEVELOPMENT SHALL BE CONTAINED WITHIN THE PERIMETER OF THE --T--T-- TELCO CONDUIT RF COMPATIBLE MONOPOLE STRUCTURE. A CONCRETE GRADE OF 8'-0" AMSL PRIOR TO START OF TO BE CLEARED PRIOR TO STARer OF CONSTRUCTION. ~ROPOSED CONSTRUCTION. --E--E-- ELECTRIC CONDUIT FOUNDATION IS TO BE DESIGNED BY A NEW YORK STATE EQUIPMENT PLATFORM CONSTRUCTION. LICENSED PROFESSIONAL ENGINEER. SIGNED AND SEALED 2. THE AREA BELOW THE ELEVATED STEEL EQUIPMENT PLATFORM --TiE--TiE-- TELCO & ELECTRIC CONDUIT DOCUMENTATION FOR THIS WORK SHALL BE FILED BY SHALL BE EXCAVATE~) DOWN TO CLE~N SAND OR WELL-DRAINED 8.6-{- EXISTING AMSL SPOT ELEVATION OTHERS. EXISTING PROPERQY LI~ /~NEW #VERIZON' MESA SPAN CABINET MOUNTED SOIL. THIS AREA SHOULD BE BACKFILLED WITH LOOSE SAND AND ON NEW AT&T ELEVATED GALVANIZED STEEL GRAVEL THAT WILL BE GRADED TO ALLOW ALL STORM WATER EXISTING AMSL SPOT ELEVATIO~3~'P ~7+ PLATFORM BY OTHERS PASSING OVER OR THROUGH THE EQUIPMENT PLATFORM A PLACE TO · 7-- ..... ' ( /'~-~ ~ J[ ~. /~-~./~ ( -,( /'~ ~/sR,-n' ( /-~ NEW AT&T TELCO CONDUIT ROUTED FROM NEW ~ ~-~ ~7 [ J __ [_ ~ ' ~ J 128'~-0" ~ ' ~ ~ _ ~ ~ ~/r~ ~, AND SILT FENCING PURSUANT TO THE MINIMUM REQUIREMENTS OF MESA SPAN CABINET ALONG UNDERSIDE OF NEW /~-'~~, ~~ /~'/~ ) '~ [~,, ~ ,~ /(/ /~. ~ THE NY STATE STORM WATER DESIGN MANUAL. THESE FEATURES AT&T EQUIPMENT PLATFORM TO NEW AT&T '~%V// ~ ~ ~-/~_~: ~'-~'-~ ~'~_V[ / YE~ ~/~ ~HALL REMAIN IN PLACE UNTil THE CONSTRUCTION SEE HAS SEEN HANDRAIL MOUNTED TELCO PANEL SEE 1 AND .-~--..~._~.~ ~~~ .j.~'~ ~-C.~. ~PERMANENT]_Y STABIUZED TO PREVENT EROSION. 3oo/^-w ~u. MU.~ I.~U.~,,ur~ ~ ~~ ~ ~'4~ ALL WORK MUST CONFORM TO FEMA FLOOD ZONE REQUIREMENTS AND UNDERLYING VEGETATION TO BE REMOVED ~ (~ r'~ 2 ~"v~//~'~ /-~('~.0 k I- ~/,~ / ~NEW AT&T TELCO AND ELECTRIC CONDUITS NEW AT&T LTL GPS UN[i' MOUNTED TO~'N'~W~/ ~ ~ ~ ~ '~~ ~ ( ~ ')~ I ~'d ~{ )~ ~ [' ~{ ) ~ ~--~/ ~/)~ DSCONNECT TO NEW AT&T TELCO AND ELECTRE N~.W ~. ~\ ~ ~ ~ / /5 ~ PANELS MOUNTED ON NEW AT&T EQUIPMENT EQUIPMENT PlaTFORM HANDRAIL SEE SOl/A-6 ~ · ~ ~ ~/ ~ PLATFORM. SEE VA-~, ~ AND SBB/A-~ AND FOR MORE INFORMATION H ~\ W~ ~-~ -~ 1/E-1 FOR MORE INFORMATION ~) .~ ,URCE= DAS,N~ STACKED. NEW BSU ~ / ~ ~ -- ---- ....... ii ~ ,= ~~~--NEW ~o sQ. ET. *,&T FENOED L~ AREA TO BE INSTALLED IN NEW PURCELL FLX16WS ~/ ~- ~ ~-~ I ~ CABINET. SEE 1/A-5 FOR MORE INFORMATION~ ~' --...... / x~ ~=~j~T~;~- ~ [ ~ 7+ ~ I' ! I. ALL PROPOSED LANDSCAPING SHALL BE ~'I . i x ( ~ ~i ~LANTED TO PROVIDE CONTIGUOUS SCREENING NEW AT&T TELCO AND POWER PANELS MOUNTED 3 5 ~ ~ ~ )~ ' ~ I - - i ~'~ /' ~ I TO THE NORTH AND WEST OF THE NEW - ~ ~. I .,; ~. LA.DSCAR,.G TO BE XE. ,. GOOW.~LT~ ~. / ~ x L. I 3ONDmON AND SHALL BE REPLACED SHOULD , ~z ~ / ~ll \ ~ / ~ ~ ~ ~ ~ I ,x ~-~~ ~ kNY TREE(S) DIE AT ANY POINT DURING THE ~ /~.~>~ ~., ~_ ~J~ :11 ~ ~ ~ ~ ~ ~ ~ I [ ~-~ '~ .~ ~1' ' DURATION OF THE SITE BEING IN USE. NEW AT&T EMERGENCY GENERATOR RECEPTACLE / '/~0~2'~ ~ .~ MOUNTED TO SIDE Of POWER PANEl SEE 1/E-1 /' q"~u'~\ 'N,' .~~--._ ~1' a' /,.-~' . I I ' I~ I~I I I .... NEW AT&T E UIPMENT CABINETS MOUNTED " FOR MORE INFORMATION ' \ O. I~~ O~ ~ ( ~I Q 0 ~ ~ ~. . NEW ELEVATED GALVANIZED STEEL PLATFORM, ~ I /'.-~-~x ? ~;--NEW ,.-o- H,GH C.AI.L,.K FE.CE WIT.?' : ,~ ~ LOCK. ABLE GATE AND GREEN 'PERMAHEDGE ~ f/~&~ / ~ PR~ACY S~,* OR EQDAL. SEE S,EET A-, FOR / t \/~li~/ / ~~ I I1~11 / ~-~ ~,~ ~' ~~ -~ MORE INFORMATION EKISTIMG CONTOUR ~NE, ~P~ ? 7¢ ~ EGR MORE INFORMATION ~ , ABOVE - '" \ I1' I ~. \ \ > N COMPA~B~ CONC~ENT ~ONOPOLE. ~. (2) / / /~ ~ ~ C~LE ICE BEID~E PO~. SEE 801/A-6 FOE SECURED TO N~ ATST ~TEN~ ~ F~E. SEE a/A-4 FOR MORE INFOR~TION A~N~ PER SE~OE~EE 1/A-3 AND 3/A-6 FOR/ / / ~-~ ~ MORE INFOR~TION SUPPO~ ~CK ~E. SEE 1 ~D 1104/A-5 MORE INFOEmTION~ / / ~ ~/E~ ~ FOR MORE INFORmTION ~ N~ AT~T CO~L A~EN~ CABLES RO~ED .~ .o-~ .,~. ~..~ .~ co. HATI.~F ~o.c~.~/ / ~ TH.o~..~ ~,~ ,c~ ..,~ ~o .~ MONOPOLE (TO BE E~END~LE TO 90-~)~ ~ J / MONOPOLE ~.,~ ~LE ~o..~Tio. BY oTHer. ~ .oTE .o~ / ~L SITE P~N ,F THiS SHE~ IS 11' X lr REaR °' 2. ~ ~ ~ ,~ ......... ~~~~ NORTH A R C H I T E (' T S. L L P NY7320 & ./~ ,~ ~on~ ~" ~* l~ >'~ i ~ PARTIAL SITE P~N i ~ (3) NEW AT&T LTE ANTENNAS AND (6) MHAs MOUNTED WITHIN RF COMPATIBLE · ~, 70'-0":1: AGL ~~ CONCEALMENT MONOPOLE, ~YP. SEE 3, 4 AND 5/A-6 FOR MORE iNFORMATION ~T.O. NEW R.F. COMPATIBLE MONOPOLE -- (EXTENDABLE TO 90'-0") (5) NEW AT&T UblTS ANTENNAS AND (6) MHAs MOUNTED WrTHIN RF COMPATIBLE ~-~ 67'-0'± A~L ~ ~ CONCEALMENT MONOPOLE. 3YP. SEE 3. 4 AND 5/A-6 FOR MORE INFORMATION I / / (TO BE EXTENDABLE TO I ~ ~ / NEW AT&T COAXIAL ANTENNA CABLES ROUTED WITHIN NEW AT&T .~ / / B~ONO. BEE ~A-~ FOR MO.E __~ / / BEYOND. SEE 1121A/A-6 FOR MORE INFORMA~ON ..i: / // .~,A,A-~FORMORE,,FORMAT,ON ., / // / ~C, E.E. BEE .,OB,^-B FOR MORE '"FOR"~-- / // /// / .EWAT&TANTE--CABLEB.PPORF~O..BEE3,A-'FORMORE'"PORMA-- ~T.O. NEW S.RUeS ~ ? / // / / / / / ELEVATED PLATFORM, bP. SEE ~/A-B FOR MORE ~.FORMAT~ON .~,_~± A~L I 2 ~~~ R ~.Ew ~-vAN,ZED ~EL EL~VA=O =IPME., P~TFORM. B~E ,/A-B FOR MO~E ,NFOR.T,O. --A--A-- A~ENNA CABLE ~ .~ ? / / / NO~= m CONDU~ POLE ~35 T~~~66/A-4 FOR MORE ~ ~ ~ ~ ............... )IS TO BE DESIGNED ~ A N~ YORK EAST ELEVATION .~ ~ ~LEc~ CON~.m~ T.~.~.E~ U.~OU.~ ~0..~ ~ .~. AN~ ~ ~ ~= ............ ~ ~C ~0~ ?0. ~ms .o.. .o~. DISCONNECT SUPPO~ ~K TO N~ AT~T ELE~RIC P~EL MOU~D TO N~ EL~ATED~ ~ ,~,, ~m~c~ ~ ~v~'~~D BY O~ERS. ................ ' ...................... 40200 MAIN RD 15 ~ST MID'ND AVENUE ....... ~ ~" ,, ~.o I ~,=,o I . *r~L~.n ~...~· TRENCH FINISH GRADE. MATCH 3. OCCUPANCY IS LIMITED TO PERIODIC MAINTENANCE AND INSPECTION. APPROXIMATELY TWO TIMES PER MONTH. BY ClNGULAR = ' ~ / SLOPE AND THICKNESS TECHNICIANS. OF EXISTING 4. NO NOISE. SMOKE, DUST OR ODOR WILL RESULT FROM THIS PROPOSAL. ~--'~; COMPACTED BACKFILL PER 5. ALL MATERIALS SHALL BE FURNISHED AND WORK SHALL BE PERFORMED IN ACCORDANCE WITH ClNGULAR PROJECT ~~SPECIFICATION EARTHWORK SPECIRCATIONS AND LOCAL CODES. ~--H--i--,i;~-m~ ~-----i;_-_l_l:_~i~ ~ I- UNDISTURBED SOIL 6. SUBCONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL PERMITS AND INSPECTIONS REQUIRED FOR CONSTRUCTION. ~ ~- 7. SUBCONTRACTOR SHALL BE RESPONSIBLE FOR REPAIRING ANY DAMAGE CAUSED BY THE CONSTRUCTION OPERATION. ~/~~:,,~ ..--m ~--~-~-_-_~ ~= ~ ~ WIDE METAL CORE, 8. SUBCONTRACTOR SHALL REMOVE ALL TRASH AND DEBRIS FROM THE SITE ON A DALLY ~lS. ~, m--~=::::-:~UNDERGROUND WARNING RIGID STEEL , RIGID GALV. STEEL B. CO~CTOB SHALL FIELD ~RI~ ALL EXISTING CONBITIONS AND PLAN DIMENSIONS. CONT,CTOR SHALL NDTI,,' THE =,_ :- =--:?--~-->~' CO.DUIT PLUG ~_~ CONDU,T COUPUNG TAPE PRINTED WITH 'CAUTION ENGINEER AND BECHTEL COMMUNICATIONS OF ANY DISCREPANCIES PRIOR TO ORDERING MATERIALS OR PROCEEDING WITH ~, ~,-:._:~--:~~--;~ BUR, ED ®~ UNE~ ~--~ G~ CONSTRUe"ON. ~i ~-~---- ,O.P.OTOG~H AND DOCUMENT E~,S. NG BU,LD,.G OR S~E COND~ONS OB D~.GE WH,CH M,G~ OTHE.W,SE BE CO.STBUED ;q ~ ~ 2x12 CCA.04 TREATED TO HAVE BEEN CAUSED BY WORK UNDER THIS CONTRACT. ~-~]:~- CONTINUOUS PLANKS PAINTED RIGID GALV. \\ Il. THE SUBCONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS ACCORDING TO THE MANUFACTURER'S SPECIFICATIONS ~ ~---T RED; NUMBER OF PLANKS AS STEEL CONDUIT PVC SCHEDULE UNLESS NOTED OTHERWISE OR WHERE LOCAL CODES OR ORDINANCES TAKE PRECEDENCE. ~ I1~__ %'~ ~r ~-_,__ REQD FOR WIDTH OF 40 SIZE AS 12. THE SUBCONTRACTOR SHALL PROTECT EXISTING IMPROVEMENTS, PAVEMENTS. CURBS, LANDSCaPiNG AND STRUCPJRES. ANY RIGID GALV. STEEL SHOWN ON DAMAGED PART SHALL BE REPAIRED AT SUBCONTRACTOR'S EXPENSE TO THE SATISFACTION OF OWNER. ,, ~ ~'---BACKFILL (SAND OR TO PVC ADAPTER LAYOUTS 13. ALL EXISTING ACTIVE SEWER, WATER. GAS, ELECTRIC, AND OTHER UTILITIES WHERE ENCOUNTERED IN THE WORK, SHALL BE ~ I1~ :~ ~- EARTHWORK SPECIFICATION DIRECTED BY ENGINEERS. EXTREME CAUTION SHOULD BE USED BY THE SUBCONTRACTOR WHEN EXCAVATING OR DRILLING SCH. 40 PVC ~ ~' ~ ---~--~ HATrVE SOIL) PER PROTECTED AT ALL T~MES. AND WHERE REQUIRED FOR THE PROPER EXECUTION OF THE WORK, SHALL BE RELOCATED AS TELEPHONE ~-~ SCH. 40 PVC PIERS AROUND OR NEAR UTILITIES. SUBCONTRACTOR SHALL PROVIDE SAFETY TRAINING FOR THE WORKING CREW. THIS WILL CONDUIT (1 / INCLUDE BUT NOT BE LIMITED TO A) FALL PROTECTION B) CONFINED SPACE C) ELECTRICAL SA~'E'FY ACTIVE. CONDUIT /_ POWER CONDUIT EXCAVATION. AS REQUIRED)/6~ ~ 4' MIN TO SECONDARY ELECTRIC 14. ALL EXISTING IHACTNE SEWER, WATER. GAS, ELECTRIC AND OTHER UTI[JTIES. WHICH INTERFERE WITH THE EXECUTION OF THE SIZE PER LOCAL ~ ~ · WORK SHALL BE REMOVED ANDw~oOR CAPPED, PLUGGED OR OTHERWISE DISCONTINUED AT POINTS WHICH WILL NOT iNTERFERE TEL. CO.~ ' 12" MIN TO PRIMARY ELECTRIC WITH THE EXECUTION OF THE RK, AS DIRECTED BY THE RESPONSBLE ENGNEER, AND SUBJECT TO THE APPROVAL OF THE OWNER AND/OR LOCAL UTILITIES. 15.THE AREAS OF THE OWNER'S PROPERLY DISTURBED BY THE WORK AND NOT COVERED BY THE MONOPOLE OR EQUIPMENT SHALL BE GRADED TO A UNIFORM SLOPE AND STABILIZED TO PREVENT EROSION. DETAIL @ UNDERGROUND ~s.suBCo~.~CTOa SHALL MINIMIZE D~STUR~NCE TO EXISTING S~ DUR,,G CONSTRUCTION. EROSION CONTROL MEASURES. ,F REQUIRED DURING CONSTRUCTION, SHALL BE IN CONFORMANCE WITH THE LOCAL GUIDELINES FOR EROSION AND SEDIMENT ~'~DETAIL @ TYPICAL UTILITY TRENCH ~ CONDUIT STUB-UP CONTROL. 17.THE SUBCONTRACTOR SHALL PROVIDE SITE SIGNAGE IN ACCORDANCE WITH AT&T PROJECT TECHNICAL SPECIFICATION FOR SITE SIGHAGE DOCUMENT NO. 24~97-011-O00-3PS-AO02-O0013. //~CUT POST LENGTH TO SUIT BY REMOVING UNCAPPED END NOTES: 1.WHEN USING COMPONENTS AS SHOWN IN STANDARD [PN WB40001 OR WB40002 DETAILS, MAXIMUM ALLOWABLE SPAN BEqWEEN SUPPORTS /~RIP LOOP, OUTUNE OF REAR OF UMTS /'~CONNECTOR PAIR /'-BCCH/OPS UNIT MOUNTED TO // / (SEE TABLE)] ON A CONTINUOUS SINGLE SECTION OF BRIDGE CHANNEL/ TYP. NODE "B" CABINET~ /WEATHERPROOFED ~CABLE SUPPORT RACK _~~,~ WIDE, ,~ LONG ICE SHALL BE B ~ET FOB ,0 FE~ BRIDGE C~"NEL. U~ \U~S/ /~UMPER TERMIHATION AT <' TO SUIT CHANNEL SECTIONS, THE SPUCE SHOULD BE PROVIDED AT ~. m:~ (2)-1/2"~ EBll COAX FROM LAST THE SUPPORT, IF POSSIBLE, OR AT A MAXIMUM OF 2 ]--B r × JUMPERS /SUPPORT TO --'--£PNWB, OS SEETABLE FEETFROMTHESUPPORT. ,,VD sIT,ON'_/NOK'A (2) TRAPEZE KITS ARE INCLUDED 3.WHEN USING COMPONENTS. SUPPORT SHOULD BE IH1l:l~dt/~lldl I~1 ( [ I y / I CABINET LEAVE: ~_~ rl/2" JUMPED ~' '~1 WITH iCE BRIDGE. ORDER BRIDGES, WITH A MAXIMUM CANTILIVER DISTANCE OF 2 WITH -- . ,.c~ BR,DQE CNANNEL SEC~ONS S~L HAVE RAW ~GES S'-~. ~'N~. ~~ ~----~POWER TO DROP -suPRoRT ~ ~ANTENNA CABLES ARRANGEMENT TREATED WITH A MATERIAL TO RESTORE THESE EDGES TO MIN* ' TYP. --- 24VDC 24-#8 ~4 ~ '(~.__ FR/~JaE ~ ~ BY SUB-CONTRACTOR THE OR'G'~ C~NE~ OR EQU~ALENT, F'N'SH. II IIIIIII IIII III II I1 III III Ilil III H -- --- ~r;rn AND =-~',~GND ' ,. ~ ,.,~,,, MANUFAC RER'SAPPROVAL. .} ¢~.~ PART jt Q'P¢. 7.DEVIATIONS FROM ICE BRIDGE FOUNDATIONS REQUIRE ~ , ~T,~NNA ENGINEERING APPROVAL. ~ .TS PART ~,T-CB2SB CABLE SUPPORT ~. ELEVATED ICE BRIDGE DETAIL ~FOR EQUIPMENT CABINETS ~ ~'~ ..........:~h ~ ~.~- . ~- ~ . ORIENT BY THE SEA RESTAURANT at&t .......''~ -- . .~. ~.~~t 0~_¢~.,,4!i~¢ AT&T MOBILITY NYCENY1059 / L1-1059 £ ~'~' ...... ")' ~ -~- ' / "; ^ , c , i T E C T S. L L ~ NY7320 ~C,//~, t~/l~.~.,._ AND ~ENERAL NOTES ..... ...................... ORIENT POINT, N.Y. 1~9~7 PARAMUS. Na 076~2 :, . ~,~97IN¥CE~Y~O~I A-4 PIGTAIL . TO FOR 1 '-§~ EACH DROP · ~ ~'~.~ I, · 6,29" = (263,~1mm) (159.87mm) 10,25' (260.~.Omm) ~ - SIZE AND WEIGHT TABLE · ; .'F ~ ~' ~' ~' HEIGHT W/O CABLE WEIG~ ~U~ ~0~ RIGHT SIDE ~ BOLT HO~ P~N ~P) ~ ~ ~ ~ ~ ~ RRH 700 MHz 12.~ I0.~ 21" 51 LBS. NO~: P~ ~ ~ ~ 2X40 (8OW) A~ACH ~IN~ TO EXI~ ~EEL B~M/G~NG/PURCE~ CABIN~ USING 1/~ D~ BOL~/J-BOL~. NO~: DIMENSIONS INCLUDE MOUSING BRACK~, SO~R SHIELD AND CONNECTORS. WE,~ 5~ ~S ~ ~ ~ ~ MINIMUM CL~NCE TABLE FIBER AND POWER ~o.3~3'(~.*~)(~ ~QUIPMENT CABINET ~ DISTRIBUTION BOX DC2-48-60-O-9E zE.o R~R CL~NCE IS ALLOWED USING ~SCALE= i 1/2.=1, O. R~R 2" SUPPLIED MOUNTING B~CK~ RIg~ 4" AIR FLOW LE~ 4' AIR FLOW TOP 1~ AIR FLOW ~ ~ ..... ALCATEL-LUCENT 9442 ~ ~ , -~. ~ ~OTE RADIO H~D (RRH) DETAIL m ~~ I :~ 0 /~~ 0 DC2-48-60-O-9E. SEE ~ ~ J ~~~ ] NO~ 4 AND DgAIL 1100 THIS ; OJ (l~MIN.x~xl/~) ~0/ N~ AT&T E~ATED EOUIPME~ P~TFORM, RH) REMOTE~,.~ RADIO HEAD (R RACK DETAIL ~ ~'~'~ ~ ~.. ORIENT BY THE S~ RESTAURANT ~ ~J.~ ~ ATkT ~O~ILI~ A R C H I T E C T S, L L P NY7320 RRH CABIN~- CLEARANCES COMMENTS (INCHES) FRONT 56" INSTALLATION ACCESS ZERO REAR CLEARANCE IS ALLOWED USING REAR 2" SUPPLIED MOUNTING BRACKETS RIGHT 4" AIR FLOW LEFT 4' AIR FLOW TOP 12" AIR FLOW BOTTOM 12~ CONDUIT ROUTING 6 5 4 ~ 3 2 ...... c,,o.o,] Sm TYP. VIEW B ANTENNA MOUNTING BRACKETS TO BE PLACED AS VIEW A CAP, BY OTHERS MOUNTING BRACKETS BY OTHERS, TYP. OTHERS [NOTE: L~ FOR ANTENNA INFORMATION SEE DETAI 2 AND 3 THIS SHEET. O.D. MAST MOUNTING BRACKETS BY OTHERS, 3YP. FLANGE BY OTHERS ISOMETRIC DETAIL ~ ANTENNA MOUNTING PLATES SCALE: N.T.S. COAX __ CABLES ~ DETAIL 'B' @ MOUNTING PLATE SCALE; N,T,S. NOMINAL DIA. ON.) lB MAXIMUM WIND LOAD (MPH) 100 MATING FLANGE THICKNESS (IN,) 2.5 AT[ACHMENT BOLT QUANTI~( 6 ATTACHMENT BOLT DiA. (IN.) ATTACHMENT BOLT 7 LENGTH (IN.) NOTE: I 1.POLE WEIGHTS ARE APPROXIMATE AND ONLY INCLUDE THE WEIGHT OF THE STEEL POLE. THEY DO NOT REFLECT THE WEIGHT WITH ANTENNAS AND CABLES. 2.PRIOR TO FABRICATION OF THE MATING FLANGE, VERIFY WITH MANUFACTURERS ITS DIAMETER AND THICKNESS, I~PICAL ANTENNA MOUNTING DETAIL NOT USED UrnS/LTL MANUFACTURER ANDREW MODEL DBXNH-6565A-A2M BAND DUAL FREQUENCIES, MHZ 700MHz to 2100MHz POL DUAL RET INSTALLED L, IN 50.8 +/- W. IN 10.6 +/- D. IN 5.2 +/- WT, LB 34.2 +/- TYP. UMTS/LTE ~ ANTENNA DETAIL SCALEI NOT TO SCALE ii WILLIAM F. COLLINS. A]A A R C H I T E C T S. LLP ORIENT BY THE SEA RESTAURANT NYCENY1059 / L1-1059 NY7320 40200 MAIN RD ORIENT POINT, N.Y. 11957 ANDREW TOWER MAST AMPLIFIER MOuNTL-BRACKETs/4, ToKIT1 1/2" ~ ~GPS ANTENNA GALV. STEEL OR ALUM, INSTALL WEATHER ANTENNA MANUF. CADWELD ON STEEL PIPE, INSTRUCTIONS CLAMP TO ALUM. COAX CABLE ~PE ' P,PE) OR ~ ._ /--(W/N-MALE C-11N (3/4' & 1 CONNECTOR) C-22 (1 1/4' & 1 1/2" "1 COAX CABLE 2 AWG GROUND WIRE LUG ~ TO CRGB 'P' SECTION OR ELEVATION NEAREST 'P' SUPPLEMENTAL GROUND BAR (L-BRACKET MOUNT) INSTALL WEATHER PER ANTENNA MANUF. INSTRUCTIONS PROVIDE APPLICABLE PIPE-TO-PIPE CLAMP ICE BRIDGE POST -- OR SIMILAR POST. :OLLAR (1-5/16" O.D.) X 3'-0" MAX. CALV. STEEL OR ALUM. MOUNTING PIPE CABLE CLAMP (BURNDY ~%'PE C-11N OR EQUIV.) BUSHING (GARVIN P/N GCHKIO0 WITH GROUND LUG REMOVED) -- COAX CABLE (W/N-MALE CONNECTOR) COAX CABLE SUPPORT 2 AWG GROUND WIRE CADWELD TO POST ONLY IF GROUNDED, OR LUG TO CRGB ELEVATION 'P' SECTION OR NEAREST 'P' NOTES: (COLLAR MOUNT) SUPPLEMENTAL GROUND BAR 1. LOCATION OF ANTENNA MUST HAVE CLEAR VIEW OF SOUTHERN SKY AND CANNOT HAVE ANY BLOCKAGES EXCEEDING 25 · OF THE SURFACE AREA OF A HEMISPHERE AROUND THE GPS ANTENNA. 2. ALL GPS ANTENNA LOCATIONS ~IUST BE ABLE TO RECEIVE CLEAR SIGNALS FROM A MINIMUM OF FOUR (4) SATELLffES. VERIFY WITH HANDHELD GPS BEFORE FINAL LOCATION OF GPS ANTENNA. 3. CADWELDING SHALL NOT BE PERFORMED ON ROOFTOPS. 4. LTE-GPS ANTENNA SHALL BE LOCATED 10' FROM ALL ANTENNAS. E911 / LTL GPS ANTENNA ~AP~IPE AND L- BRACKET MOUNT at&t AT&T MOBILITY 15 EAST MIDLAND AVENUE PARAMUS, NJ 07652 3 NOTES: THE TMA CAN BE MOUNTED TO A SUITABLE FLAT SURFACE. 1. THE REAR BRACKETS AND HARDWARE NOT USED. 2. IF PRE-INSTALLED. 3/8-16 UNC x 6 1/4" LG (MB X 160 MM) HEX BOLTS MUST BE REMOVED PRIOR TO 3. ATTACH THE REAR BRACKETS TO THE HEX BOLTS AND INSTALL FEAT WASHER, SPLIT LOCK WASHER, AND THE HEX NUT ON EACH BOLT. TIGHTEN HEX NUTS SECURELY WHILE MAIhrTAJNING ALIGNMENT BET~/EEN TMA BRACKET AND REAR BRACKE%. 4. A1TACH A GROUND CABLE TO THE TMA USING WALL-MOUNTING. UNDO THE ~NO CAP SCREWS TO DETACH THE PRE-INSTALLED HEX BOLT AND WASHERS. THE TMA BRACKET AND RETRACT THE BOLTS. RE-INSTALL ROUTE THE GROUND CABLE TO THE GROUND THE TMA BRACKETS AND TIGHTEN THE CAP SCREWS SECURELY. 3. MOUNT THE TMA TO THE WALL USING FOUR 5/16" OR 8 MM BOLTS (NOT SUPPLIED) THROUGH THE HOLES IN THE TMA BRACKETS, 4. CONNECT RF AND GROUND CABLES, WEATHEESEAL AND SECURE WITH STRAPS AS OUTLINED ABOVE. NOTES: ASSEMBLE THE POLE MOUNTING HARDWARE ON THE TMA AND INSTALL THE DESIRED LOCATION AS SHOWN IN DETAIL ABOVE. 1. INSERT THE 3/8-16 UNC x 7' LG (MB X 180 MM) HEX BOLTS WITH THE WASHERS THROUGH THE HOLES IN THE TMA BRACKETS. BOLTS AND WASHERS MAY BE PRE-INSTALLED ON SOME VERSIONS OF THE ETB SERIES TMA. 2. ORIENT THE TMA IN THE SELECTED LOCATION WITH THE STS POET POINTING DOWN, OR AS REQUIRED. ALIGN THE V-GRIPS OF THE TMA RACKETS WITH THE POLE OR TOWER MEMBER. BAR ON THE TOWER STRUCTURE AND ATTACH SECURELY WITH SUITABLE FASTENER. 5. ROUTE A JUMPER CABLE FROM THE B50 MHz ANTENNA TO THE TMA PORT MARKED 'ANT 850'. ROUTE A SECOND JUMPER CABLE FROM THE 1900 MHz ANTENNA TO THE TMA PORT MARKED "ANT 1900'. ROUTE A THIRD JUMPER CABLE FROM THE TMA PORT MARKED "BTS" TO THE TOWER FEEDER, BE SURE TO PROVIDE ADEQUATE CURVE OR LOOP TO RELIEVE UNDUE SIRAiN ON CONNECTIONS AT EITHER END. 6. TIGHTEN RF CONNECTIONS TO 16 ET-IRS (25Nm) TORQUE. 7. WEATHERSEAL THE CABLE CONNECTIONS PER STANDARD PRACTICES IF REQUIRED BY LOCAL CONDITIONS. PROVIDED MATERIALS IF ANY, CAN BE APPLIED ACCORDING TO THE INSTRUCTIONS ON THE PACKAGE 8. APPLY CABLE TIES OR STRAPS (NOT SUPPUED) TO SECURE THE CABLES TO THE TOWER STRUCTURE. POWERWAVE UMTS TSAW-O7BP111-001 TMA NOTES: 1. UNSCREW THE BAND CLAMPS UNTIL THE END COME LOOSE AND THREAD THE ENDS THROUGH THE SLOTS IN THE MOUNTING BRACKET AS SHOWN, BEING CAREFUL NOT TO SCRATCH THE REAR FACE OF THE TMA. 2. MOUNT THE TMA TO THE MOUNTING PIPE USING THE BAND CLAMPS AND TIGHTEN CLAMPS TO A TORQUE 3. AT[ACH THE JUMPER CABLES TO TMA CONNECTORS Jl(850/900MHz PORT) AND 2 (1800/1900/2100 MHz PORT) AND TORQUE NUTS ON THE DIN CONNECTORS TO 2041b-ln (23N-m). REPEAT WITH FEEDER CABLE CONNECTION TO TMA CONNECTOR J3 (COMMON PORT). 4. GROUND TMA BY AT[ACHING A GROUND STRAP TO THE M8 GROUNDING STUD ON THE SIDE OF THE UNIT. ANDREW GROUNDING KIT, PART NUMBER GND-1M-RT, OR EQUIVALENT, MAY BE USED. APPLY ANTI-CORROSION PASTE TO THE GROUND CONNECTION. 5. WEATHERPROOF THE TMA CONNECTIONS USING ANDREW WEATHERPROOFING KITPART NUMBER 221213 OR EOUNALENT. FOLLOW THE INSTRUCTIONS SUPPLIED WITH THE KIT TO WEATHERPROOF THE CONNECTORS. 6. STACKING UNITS: TO STACK TWO UNITS, REMOVE THE FOUR EXISTING MGx5Omm SOCKET HEAD CAP SCREWS THAT ATTACH THE TMA OF THE MOUNTING BRACKET AND ATTACH TOGETHER USING FOUR MGxlOOmm SOCKET HEAD CAP SCREWS PROVIDED WITHEACH UNIT. MOUNT THE TMA TO THE MOUNTING PIPE USING THE BAND CLAMPS AND TIGHTEN CLAMPS TO A TORQUE OF 901b-in (10.2 N-m). CONTINUE INSTALLATION WITH STEP 3. AT&T MOBILITY ANTENNA MOUNTING DETAILS NYCENY1059 A-6 /~CORNER, GATE. END OR PULL POST ICL~ OPEN,.G /~2 1/~ O.D. POST - /10'-~ O.C. (~ ~ ~YPICAL WOVEN WiRE F~NCING NOTES CORNERTERMINALposTs)AND I ~ TOP NAIL v TOP RAIL 1. INSTALL FENCING PER ASTM F-567, WING GATE PER ASTM F- 900) ~ STRECHER BA~ 2. GATE POST. CORNER. 3ERMINAL OR PULL POST SHALL · ~ GATE LATCH BE 2 7/~'~ SCHEDULE 40 FOR GATE WIDTH Of 4 ~ WITH LOCK FEET PER ASTM-F1083. ~ ~ 3. LINE POST: 2-3/8"e SCHEDULE 40 PIPE PER ~. ~ ~,, ~c 4. GATE FRAME: 1 1/2"e SCHEDULE 40 PIPE PER y9GA. CHAIN LINK L~ . t ASPHALT PAINT. /' .~ - PORTION Of PIPE I · I ~ BE PAINTED WITH ~ 1~ ~ ' [ ELEVATION ~- SECTION 1~ __ CONCRETE SKN.L CUT BACK DETAIL @ WOVEN cUT BACK ~B~A~.IL @ WOVEN WIRE FENCE DETAIL ~WIRE FENCE DETAIL .~'~DETAIL @ WOVEN WIRE GATE DETAIL AROUND TEEN TRUNKS AND TWINE FROM AROUND s'-o' o.c. SEE V^-2 FOR ~ -~ .~ TO PROVIDE CONTIGUOUS SCREENING ~0 ~HE ~o~r~ ~C"EDULE DETA'L ~ ~1~ ............ Ii ~ ~ ~'~~ NYCENY1059 / L1-1059 ~ "~'~ ........ ~.~'~, L~ '~ ^ ~ c H I · ~ ¢ T S LL~ NY7320 ~ ~ ........ ~ ~J '': ~ ARCHITECTURAL D~AILS 'V ........................ OR'ENT POINT. N.Y. 11957 FARAMUS, '" ..... I ..... I ....... ~ 0/.- ~\.~,~-.} .";~/897 I NYCENY10591 A 7 1. ALL STEEL WORK SHALL BE FABRICATED AND ERECTED IN ACCORDANCE WITH CURRENT AISC SPEClFICA'rIONS. ALL STRUCTURAL S3EEL BEAMS CONFORM TO ASTM A-56 UNLESS 01HERWISE NOTED. ALL MATERIALS TO BE HOT DIPPED NEW REMOVABLE GALVANIZED AFTER FABRICATION. BEAMS THAT ARE SHOWN TO BE TOO LONG TO HOT-DiP GALVANIZE MAY BE SPUCED HANDRAIli~/4' ~ ~' 6'-{~ MAX. ~. 1'-~ k DEVELOPING FULL STRENGTH OF MEMBER DESIGNED BY STEEL FABRICATOR. NEW 4"x ~NEW 1 1/~ GALVANIZED 2. ALL WE~,NO S~L BE PEREORMEO US,NG ETOX, ELEC~OOES ~0 WELD,,G S~LL CONEOR, TO A,SC ANO AWS D,.,i K'CK P~'~,~,X~ /STEEL.D~LTO BE , ,,~, STANOARD E~OW s~RRA~o STEEL 2~A-B FOR ~RE 7. SEFO,E P,OCE~,~ W~, F~,~GA~O, ~D E,ECT~O,. T,~ CO~CTO, S~ SUSa~ S,OP ~w~,m TO ~ ~/~' HANDRAIL ELEVATION EQUIPMENT P~TFORM CON'RUED ~ A COMPmE CHECK B~ WILL INDICATE ONLY ~T GENE~ M~OD OF CONDUCTION ~D D~AILING /~ ~ ~EEL GRAT~NC~ ~L WRIED 26'-0 ~/8"W14x22 ~-~--~ ~~~ T TM N~ 4"xl/4'~~~ ~ > ~- , ~ , REPRESE~ N~ AN~LE~~ ~ ; , ~ - W14X22 B~OND, ~P.~~ ~ )) ~ ~VANIZED ~EEL P~ , , , N~ W14x26 m m W14x26 ~ ~ * m m i m P~CES~ C10x15.3 STRINGER WP. ,, 1 2 1/ .~ '-4 3/~ ~ NR E~INED) 1~ ~ ~ ~I, ~ ,~::::~, ()~ ........ ....,, . , ,, l~e POURED CONCEDE ~ ~ WITH (4) 1~ LONG ~4 RE~R ~CH. WELDED 1~ O.C. ' ...... -:::~ ..... ~-- ~BO~oMTO BO~OMoF RE~,OF P~TE.wp.PROVIDEFoR (4)-- ~ HOOK AT~ --~=I~"' J-'~ ---~=[=) .... ' ~ DAYs,PsISONOTUBEcoNCR~EAIR E~NED)PIER'AT (4'028 ~ =~1":~ ~:m':: 'ml~::J-- ~ '"ilmm gAg~~~jrvv''~ ~Vn~l'L ' L ~ ' ~ ~ ~m 4/A-8 FOR MORE INFOR~TION m m , m m mm SEE 5/A-8 FOR MORE mNFOR~TmON , ir ~ ,, , ~ ,,'"' ..... ."" ~ ~ STEEL ACCESS STAI~~ ELEVATION ~ ~[~ 0~' 6'~'~11 AT&T MOBL~ ¢ ~ ORIENT BY THE S~ RESTAURANT ~ ='~= .......... w]~]A~ ~ ce~]~s,~* NYCENY1059 /L1-1059 ~ ~'/~ .......... Illll I 22 x 54 'D' SIZE NOTES: SUBCONTRACTOR SHALL PROVIDE 200AMP, SINGLE PHASE, 120/240 VAC, 60HZ SERVICE FOR AT&cT SITES. SUBCONTRACTOR SHALL COORDINATE WITH UTILrTY COMPANY BEFORE THE START OF CONSTRUCTION. POWER AND TELEPHONE CONDUIT SHALL BE PROVIDED AND INSTALLED PER UTILITY REQUIREMENTS. FOR COMPLETE INTERNAL WIRING AND ARRANGEMENT REFER TO DRAWINGS PROVIDED BY PANEL MANUFACTURER. ALL SERVICE EQUIPMENT AND INSTALLATIONS SHALL COMPLY WI1H THE N.E.C. AND UTILBY COMPANY AND LOCAL CODE REQUIREMENTS. SUBCONTRACTOR SHALL INSTALL SUFFICIENT LENGTHS OF LFMC INCLUDING ALL CONDUIT FITTINGS (NUTS, REDUCING BUSHINGS, ELBOWS, COUPLING, ETC) NECESSARY FOR CONNECTION FROM THE NEMA BOX TO THE IN~RIOR BTS CABINET. SUBCONTRACTOR SHALL PROVIDE ELECTRICAL SERVICE EQUrPMENT WITH FAULT CURRENT RATINGS GREATER THAN THE AVAILABLE FAULT CURRENT FROM THE POWER U~LITY. POWER, CONTROL AND EQUIPMENT GROUND WIRING iN TUBING OR CONDUIT SHALL BE SINGLE CONDUCTOR (~14 AWG AND LARGER), 600V, OIL RESISTANT THHN OR THWN-2, CLASS B STRANDED COPPER CABLE RATED FOB 90'C (WET AND DRY) OPERATION; LISTED OR LABELED FOR THE LOCATION AND RACEWAY SYSTEM USED. CUT, COrL AND TAPE A 5 FOOT PIGTAIL FROM END OF LFMC FOR TERMINATING BY BTS EQUIPMENT MANUFACTURER. _v_ __... oozj LD L TELCO PB,OB TO PROCUB,NG ANO ,NSTA TIO. OE BBC e. CLDBURe AND COMPONE i SUBCONTRACTOR SHALL FUB.,B. AND ,.ST SUBGE PBOTECT,ON B .CEB:_S. BY ; ; NO. 90700 WITH MOUNTING DIN RAIL PART NO. 21607), BOND SURGE PROTECTION DEVICE DIN RAIL TO THE ENCLOSURE WITH i~6 AWG INSULATED WIRE (BEFeRENCE STANDARD DE~NL 1015). BOND ENCLOSURE TO THE SITE GROUND RING OR BAR WITH ~2 AWG COPPER WIRE. SUBCONTRACTOR SHALL PROVIDE 6"x6"x4# (MIN.) NEMA 3R STEEL ENCLOSURE AND MOUNT TO CONDUIT RACK AT REAR OF CABINET. NOTE TO NEW AT&T E~ 24 VDC NOTES: EQUIPMENT CABINETS 1, 24VDC CABINET INSTALLER SHALL MAKE ALL FINAL TERMINATIONS AT 24VDC CABINET. NEW AT&T EXISTING PAD 2. NOKIA INSTALLER SHALL MAKE ALL FINAL TERMINATIONS AT NOKIA BTS CABINET. NOTE DISCONNECT TRANSFORME 4. 24VDC MANUFACTURER SHALL PROVIDE AND INSTALL DC POWER CABLES READY FOR RNAL TERMINATION BY NOKIA. DC DiSTRIBUTION _ CABLES SHALL BE (2)-3/0 AWG FOB EACH STS. NOTE ~! A. ASSOCIATED CIRCUIT BREAKER FOR DC DISTRICUTION CABLES SHALL BE LEFT OPeN AND PROVIDED W/A REMOVABLE LOCKING E6 DEVICE OR TAG SO THAT THE BREAKER CAN NOT BE CLOSED. ii 5. B. DC CABLES SHALL BE RHH/RHW AND CABLE TRAY (CT) RATED. NOTE NOTE I i 6. C. NOKIA INSTALLER TO PROVIDE DC DISTRICUTION CABLES LUGS ON NOKIA END. ii 7. 24VDC INSTALLER SHALL PROVIDE AND INSTALL TELCO CABLE(S) BELDEN PART ~7919A COILED AND READY FOR FINAL TERMINATION · ~ 8. 24VDC MANUFACTURER SHALL PROVIDE AND ~NSTALL CBS DATACOM ALARM CABLE(S) PART ~C03610075 COILED AND READY FOR LNOTE 9. ALL CONDUCTORS SHALL BE DESIGNED AND INSTALLED IN ACCORDANCE W/NEC AND LOCAL CODES. A~ E5 lO~J. CABLE ENDS AT THE NOKIA BTS SHALL BE IDENTIFIED AND TAPED. SUFFICIENT SLACK SHALL BE PROVIDED TO PERMIT NOKLA INSTALLER TO TERMINATE ALE CABLES. N ~ ELECTRICAL SERVICE IS DESIGNED BY OTHERS IFOR NOKIA CABINET CONDUIT AND CABLE FOR CIRCUITS AND RATINGS SEE PANEL ~ C WITH .3-5/0 & 1 ~ 4 CU WITHOUT INVOLVEMENT OF WFC. CONDUIT ROUTING TERMINATION POINTS SEE DETAil 5 SHEET A-4. 1 SHEET E-2 SHALL BE SHOWN ON DRAWINGS. AN ELECTRICAL INSPECTION CERTIFICATE SHALL BE PROVIDED TO AT&T AND WFC AT THE COMPLETION OF THE PROJECT. UNISTRUT PIPE/.GONDUIT P2558-35 (~ ALV¢ El. COORDINATE ALL NEW SERVICE REQUIREMENTS WITH UPA PRIOR TO BEGINNING NEW WORK. (SYPICAL) F LLO MANU E2. ENGAGE THE SERVICES OF AN UNDERGROUND UTILITY LOCATING COMPANY TO LOCATE ALL BOLT TORQUE UNDERGROUND EQUIPMENT IN THE AREA. ES. PROVIDE AND INSTALL NEW 120/240 VOLT 200 AMP SINGLE PHASE MAIN DISCONNECT SWITCH. 3 1/2' O.D. POST ~ UNISTRUT P1001 (GALV) E4. FROV, DE ANB '"STALL NEW 20/24D VOLT B,NGLE 20D AMP METER. ES. PROVIDE AND INSTALL NUMBER 2 COPPER GROUND AND 3/4" X 10' GROUND RODS FOR NEW SE~C[. -L~'~RGB CONDUIT (GALV) (~P) MAXIMUM RESISTANCE TO GROUND SHALL BE 5 OHMS, PROVIDE AND INSTALL ADDITIONAL GROUND RODS NOT LESS THAN 6' APART TO MEET MINIMUM GROUND RESISTANCE AS NECESSARY. ~ ~c ~_ E6. NEW PANEL "A" IN WEATHERPROOF ENCLOSURE MOUNTED TO NEW EQUIPMENT PLATFORM RAILING. ~ E UNISTBUT P1001 (GALV) PANEL HATED AT 200A, 42kaic MAIN BREAKER, ALL COPPER BUS, 50 BOLT ON 22kolc E BREAKERS AND DOOR IN DOOR HINGED CONSTRUCTION. UNISTRUT P1001 (GALV) E7. PROVIDE AND INSTALL SURGE EQUAL TO ARRESTOR SUPPLIED WITH SSC ENCLOSURE, ~ I ~ WITH A 2P-50A BREAKER IN PANEL 'A" WITH 5 ~ 10 CONDUCTORS. ~ FINISHED GRADE ES. PROVIDE AND INSTALL CIRCUIT BREAKERS AND BRANCH CIRCUIT WIRING GFC] CONVENINENCE RECEPTACLES, ~ - 24 VDC CABINET ETC. PER PANEL 'A' SCHEDULE. COORDINATE WITH PROJECT MANAGER AS NECESSARY. Eg. PROVIDE NEW 200A, SINGLE PHASE, S WIRE PIN AND SLEEVE EMERGENCY GENERATOR RECEPTACLE. PART I~ ~ GRINWIRRELAY-RAND RECEPTACLE ~AR2OOSS-RS ~ SAKRETE PIER PIPE CAP (TYP) UNISTRUT PLO01 (GALV) ,~I~Re SCH.40 PIPE (GALV) e RGS CONDUIT (GALV) (1YP) UNISTRUT P1001 (GALV) UNISTRUT P1001 (GALV) - . .[... FINISHED GRADE : lO"e PLAIN CONCRETE OR / ';;ll~, ~KRETE PER / METER AND DISCONNECT A R C H ] T E C T S. LLP NY7320 ORIENT BY THE SEA RESTAURANT _~ -~ .... NYCENY1059 / U-1059 ~ .... 6 5 4 5 2 ' ~ ps:_SIZE` : Boo ' "z; ,oTEs FOR TE20, , US,ON AC DI~IB~O~ P~EL /B ~ ~ ~, BISCONNEO~ WIRE ~22 F~O~ N,O~ (OPEN) ON ~/0 G ~ ~ ~ TO MALE 0.25" QUICK CONNECT (RED WIRE) W R ~ ~ 3 ~ ~ ~RMI~L OF ~5 · CONNE~ LO~ (VA) ORG/W~ ~ ~ ~ 4 ~ ~ FROM TE20B DOOR INTRUSION W~/GR,~= 5 ~~ CABS. USE PRODDED FE~LE 0.25 ~U,OK BEKR BEK, ~ GRN~ ~ ~= 6 =~ CONNECT 0 50 1 (2P) 326 652 326 2 (2P) 50 ARGUS 24VDC ~BIN~ ~1 RECTIFIER ¢2 0 ~ BRN~ ~ ~ 8 ~ ~ I~RUSION ~RM ~LE TO THE N.O. 0 ARGUS 24VDC CABIN~ ~I RECTIFIER ~1 5 526 652 526 4 0 TO X9 ALP~ ~ W~/SLT ~ ~ 9 =~ (OPEN) ~RMINAL OF SW5 0 50 5 (2P) 526 652 526 6 (2P) 50 0 A~RM PO~ ~ SLT/W~ ~ 10 ~~ ~ ' ' 0 ARGUS 24VDC CABIN~ ~1 RE~IFIER ~5 7 326 652 526 8 ARGUS 24VDC CABIN~ ~1 RECTIFIER ~4 0 ~ ~ ~ RED/BLU ~ ~ 11 ~ 0 ARGUS 24VDC CABIN~ ~1 RECTIFIER ¢5 30 9 (2P) 326 652 326 10 (2P) ~ ARGUS 24VDC C~INB ~1 RECTIFIER ~6 0 ~ BLU RED ~ 12 ~ '~ 0 ARGUS 24VDC CABIN~ ~1 RECTIFIER ¢7 30 15 (2P) 526 652 526 14 (2P) 30 ARGUS 24VDC C~IN~ ~1 RECTIFIER ¢8 0 ~ ~~~)(~C ¢1. TE~ ID ~1) 0 15 526 652 326 16 0 0 ARGUS 2~C ~BIN~ ~1 RECTIFIER ~9 30 17 (2P~ 526 652 326 18 (2P) ~ ~GUS 24V~ C~IN~ ~1 RECTIFIER ~10 0 ~ ~~--~)(~C ¢2. TE~ ~ ~2) 0 19 326 652 326 20 0 0 NOKIA H~A 850 27 750 750 326 28 (2P) 50 ~12WS 0 ~ ~~ 20~ = SL~/SLT ~% %~, PANEL SCHEDULE *EWe*. = 5 ?OWER COMP~ENT (~) ExmmN~ m .... I COPPER GROUND ~R 1/4'x4'x2¢, ~ =~ !~ - KWH KILOWA~ HOUR ~ GROUND ROD W~H ACCESS LOW TEMP ~EM h;;;ORG/W~ ~ ~ ~T~~ RED ~ RED MIGB ~R ISO~TED G~UND ~R /NO BLU m ~ ~ ~ RM ~LE ~N.C. I~RUSIOh (N) N~ ~ GROUND WIRING ~E~ ~BIN~ [ · '~ L ~ ~ J ~ ~¢K ~ / F M PCS PERSO~ CO""UNI~ON ~M ~ M~ER ON M~R/BR~KER UN~ BLK CO" FROM TRICAL SYMBOLS AND ABBREVATIONS 66 BLOCK A RM ASSIGNMENTS (24VDC) *'"' ............. .-' ORIENT BY THE S~ RESTAURANT '*' ......... ; '* m. -- ~ ~ ~,f/:~j ~ ~: : ~L~TRICAL DETAILS, SYMBOLS AC DISTRIBL~TION PANEL 240-120V 1 PHASE 200A-BASED ON INTERSECT PANEL WITH STEIKESORB LOAB (VA) BRKR L1 1.2 LCL L1 L2 BRKR SIZE SIZE REV SERVICE DESCRIPTION AMPS BRKR VA VA VA VA VA BRKR AMPS SERVICE DESCRIPTION REV 0 50 1 (2P) 326 652 326 2 (2P) 50 ARGUS 24VDC CABINET ~1 RECTIFIER ~2 0 0 ARGUS 24VDC CABINET ¢41 RECTIFIER ~1 3 326 652 326 4 0 0 $0 5 (2P) 326 652 526 6 (2P) 50 0 0 ARGUS 24VDC CABINET ~1 RECTIFIER ~5 7 526 652 326 8 ARGUS 24VDC CABINET ~1 RECTIFIER 1~4 0 0 ARGUS 24VDC CABINET ~11 RECTIFIER ¢5 30 9 (2P) 326 652 526 10 (2P) 50 ARGUS 24VDC CABINET I¢1 RECTIFIER 1~6 0 0 11 526 652 326 12 0 0 ARGUS 24VDC CABINET I~1 RECTIFIER ¢7 SO 15 (2P1 526 652 526 14 (2P) 50 ARGUS 24VDC CABINET ill RECTIFIER ~8 0 0 15 526 652 526 16 0 0 ARGUS 24-VDC CABINET ~1 RECTIFIER ¢9 SO 17 (2P1 526 652 326 18 (2P) 50 ARGUS 24~VDC CABINET t¢1 RECTIFIER ¢10 0 0 19 526 652 526 20 0 0 ARGUS 24VDC CABINET ~1 RECTIFIER ~11 50 21 (2P1 326 1076 750 22 (2P) 15 0 0 25 526 1076 750 24 NOKIA HETA 1900 0 0 15 25 (2P) 750 750 750 26 (1P) 15 FLX12WS 0 0 NOKIA HETA 850 27 750 750 526 28 (2P) 50 FLX12WS 0 0 15 29 (2P) 720 5600 2880 .50 (1P) 30 ARGUS 24VDC CABINET 0 0 UMTS CABINET HEATER 51 720 720 750 32 (1P) 15 Rx-AIT 0 0 TELCO BOX RECEPTACLE 15 55 (1P) 180 180 54 0 0 UMTS CABINET RECEPTACLE 1~ 55 (1P) 180 180 56 0 0 BATrERY CABINET NO.2 15 57 (1P~ 180 180 58 0 0 59 0 4.0 0 0 41 0 4-2 0 CONDU~T W/16-1/C 8 AWG THHN OR THWN-2 AND 1-1/C 10 AWG THHN OR THWN-2 GREEN INSUL. GND. (FOR RECTIFIER) & 1/C 10 AWG GND. (FOR HV.~/~) ~] & 1/C 12 AWG GND. (FOR GFCl) (NOTES 1 & 2) ~ 5~ ~ ~ UPPER SHE~ ~ ~SEE O~L A ~ ~ ~ LOWER POWER MODULE (SHE~) H~ (5) POS~IONS FOR RECnFIERS. ~z~ ~ ~ 5~ ~ o INSTA~ CONDUIT AND CONNE~ WIRING TO RE~IFIER MODULE GND~ PE ~ ,E ~ OEPLOYEO. DETAIL A TERmiNAL BLOCK ~R~NO AC SINGLE- LINE DIAGRAM m ..... - ............. ................. ~0,00 MAIN RD 15 EAST MIDLAND AVENUE .......................... ORIENT POINT, N.Y, 11957 PARAMUS, NJ 07652 I~}~', I % ('PfP FOR 6) 3. FURNISHED BY BECHTEL COAX TO ANTENNAS J j 4.. INSTALLED BY BECHTEL. (TYP FOR 6) -- --~ 6. OPEN END OF CONDUIT TO BE LEFT WEATHERPROOFED UNTIL TERMINATED. J J J J J J J J I 7. ARGUS 053-997-20-0000 DUAL FEED DC-DC CONVERTER WITH 012-526-20-04'0 2KW MODULES. (lh'P FOR 3) I ~ ~~ ~- ~F THE UNIT OR AS SCOPED BY MARKET. WHEN IN BECHTEL SCOPE, INSTALL 10 AWG CHASSIS GROUND, / ~ ~ PROVIDE (2) IOA BREAKERS FROM A 24V ~ POWER ~URCE OR (2) §A BREAKERS FROM A 4.8V DC NOTES 3. 4 1 ~'~ ~ 11. LEAVE COILED AND PROTECTED UNTIL TERMINATED. ~\\ 1. 2, 5J/ 1, 2. 5 1, 2. 5 1. 2. 5 1, 2, 5 1, 2. 5 16. DC POWER CABLES SHALL BE COPPER. CLASS B STRANDING TfPE RHH/RHW UL MSTED FOR 90'C , ('PCP FOR 6) 19. FIBER AND POWER DISTRIBUTION BOX IS NOT REQUIRED WHEN THE DC CABLE BETWEEN THE OUTDOOR I i i I I ~(NOTE 11) CABINET ~ND RRH ~S LESS THAN SO FEET, NOTES: 3, 4, 6 -- ~ I ~ ~ I ~ 20. GROUNDING CABLES SHALL BE COPPER, THHN/THWN UL USTED FOR 90' DRY/ 75' WET INSTALLATION I I I I UNLESS NOTED OTBE 'SE. NOTES: 3, 4, 21 \ ~ , ~ 25. SEE DETAIL 11500 FOR ALARM CABLE REQUIREMENTS. j_ FOR 3) CwP OF 3) _ __ (2) 2/c DOCAB~S ' - ~ ' ('F-- CPIP FOR 3)~ I 94.12 CABINET 9926 (BBU) GPS ANTENNA & PULL BOX / ~SURGE SUPPRESSORS (2) 2 COUNT, SINGLE (AT DC2 H-FRAME) ~ NOTES. 1 2. 5 NOTES: 3. 4. 5 15' x 6" x6" (MIN.) j (TYP FOR 3) /~ (6) 2 COUNT, SINGLE MODE FIBER CABLE 2 I/2' IMC CONDUIT ) / W/ 1 1/2' REDUCER (NOTE 15) FIBER Wn'H RET WITH RET WITH RET NOTES: 3, 4, 14' _1 ~ LTD BBU LTD BBU ~ ~ ~, MP ~ ~ W NOTES: 1, 2, 5 NOTES: 1, 2, 5 "~ I ~6 AWG (,=) vc ,2 AWG ,,,,,,. ~ (2) 2 AW I A I ( ) / \ NOTES. 3 4. 2 ,m, ~ abm,yeP D~,m 1 1/2' LFMC CONDUIT I ! \ (~P ~OR' 3)' 700 TblA AWS TMA 700 TMA AWS TMA (2) 4/0 ~ (1) IOOA & NOTES: 3, 4, 5, 6 ~ NOTES NOTES ~ NOTES N01~S NOTES 3, 23 (~¢P FOR 2) JUMPER ' · (TYP FO ---- ~ ~--NOTES: 3, 4- ~1' LFNC CONDUIT .......... ----'~ ~ '--..AU_A__R__M C_AB.LE~ I (W/ PULL STRING) TO (2) 250A ~/ ~, ..... -~- ~~ u~ J_4NOTES: 3. 4. 25 I NOTES' 3 4- 6 coNVE R ' _ BYO;.ERS + BREAKERS IN <{'---~-~----- W/ 2KW MODULES OUTDOOR CA~INET SYSTEM DIAGRAM, TOWER SITE ~UTDOOR BASE BAND AND RHHs ON GROUND (2) 1/c ~ AWG~ ~7' POWER CABLES ALCATEL-LUCENT ON~ J ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ -- ~ w~ i L-I+11-1+l~ll-I+ll-I+ ' [~ *w~ ~.ou.~ = POWER ~BL~ ~ ~ J ~ ~ ~ FACTO~ WIRING ov (NO~ 4) ~D 1. ~EL THE DC P~ER ~BLm AT BOm EN~ OF ~ WIRE ~D IN A~ (NOTES WIRING DIAGRAM, OUTDOOR AT 9~C D~/75'C W~ INk--nONS. ~SE BAND AND RRHs ON GROUND, DC/DC CONVERTER ORIENT BY THE S~ RESTAURANT NYCENY'059 / L1-1059 ---GROUND NEW SUPPLEMENTARY ~ GROUNDING NOTFS ROD, TYP GROUND CABLE 2/0 AWG, 1YP 1. THE SUBCONTRACTOR SHALL REVIEW AND INSPECT THE FACILI~ (;ROUNDING SYSTEM AND MGHTNING PROTECTION SYSTEM (A~ DESIGNED AND INSTALLED) FOR STRICT COMPLIANCE WITH THE NEC (ASA~DOPTED BY THE AHJ), F' '-~ .......................................... 7 THE SITE-SPECIFIC (UL, LPI, OR NFPA) LIGHTIN(; PROTECTION CODE, AND ~- SUBCONTRACTOR SHALL REPORT ANY VIOLATIONS OR ADVERSE FINDINGS TO THE :, coNTRACTOR FOR RESOLHT,ON. -- -- 2. LIGHTNING PROTECTION, AND AC POWER GES'S) SHALL BE BONDED TO(;ETHER, ' ~/~b'/~L~ ~//~'~-~'/ ................ ALL GROUND ELECTRODE SYSTEMS INCLUDING TELECOMMUNICATION, RADIO, AT OR BELOW GRADE. BY 1MO OR MORE COPPER BONDING CONDUCTORS IN -- ~ ~ PROTECT THREADED AREA · 3. THE SUBCONTRACTOR SHALL PERFORM IEEE FALL-OF-POTENTIAL RESISTANCE TO FROM DAMAGE DURING I/ - ! , , ,_ _ [i I RTHTE NC 'ER'EEE''OOANDB' FORNEWGROUNDELECTHODE ' L J SYSTEMS. THE UBCONTRACTOR SHALL URNISH AND INSTALL SUPPLEMENTAL ;o AND AFTER INSTALLATION. 4. METAL RACEWAY SHALL NOT BE USED AS THE NEC REQUIRED EQUIPMENT CADWELD GROUND CONDUCTOR. STRANDED COPPER CONDUCTORS WITH GREEN INSULATION. ~ _ _-. .~ I i ~ 5. EXOTHERMIC WELDS SHALE BE USED FOR ALL GROUNDING CONNECTIONS BELOW I i ...... ..~ i i i B. ~PROVED A~O×~DANT COAT,NOS O.E., CONDUCT~E GEL OR P~) SHALL BE . USED ON ALL COMPRESSION AND BOLTED GROUND CONNECTIONS. / 5/8'~ X 10'-0" LONG , SURFACES TOBEOONNE DTOGROUNDOONDUOTORSSHALEBECL NEGTO , 7, A BRIGHT SURFACE AT ALL CONNECTIONS. i 8. EXPOSED GROUNDING CONNECTIONS SHALL BE MADE WITH COMPRESSION : CONNECTORS WHICH ARE THEN BOLTED TO EQUIPMENT USIN(; STAINLESS STEEL HARDWARE. INSTALLATION TORQUE SHALL / ~) 9. ALL CABLE TRAYS SHALL BE BONDED TO THE EXISTING BURIED GROUND ELECTRODE SYSTEM WITH A SINGLE CONDUCTOR ~2 AWG SOLID TINNED · J COPPER WIRE, GROUND CABLE 2/0 AWG // CABINETS, Wp. ~~ ~L~T~ @ GROUND ROD u COAX GROUND COAX GROUND COAX GROUND CAST IRON FLANGE AND GROUNDING NOTES: BAR AT BAR AT BAR AT COVER WITH WORD 'GROUND' HOLE ASSEMBLY CAST INTO COVER, MUST VERIFY THAT THE SYSTEM IS . EFFECTIVELY GROUNDED AND MEETS THE NEC ARTICLE 250 REQUIREMENTS AND ACCEPTABLE TO THE LOCAL INSPECTOR/ GROUND ROD AUTHORI1Y. NEC ARTICLE 250-84 TO EQUIPMENT ~ SPECIFIES GROUNDING RESISTANCE Of 25 TYp'V GROUND RING ~ ~ ~ r -- OHMS OR LESS FOR THE GROUNDING I-~ CABLE TO ROD CAD WELDED ' SYSTEM. THE PROJECT ReQuIReMENT iS TO MONOPOLe ~ ~~l~~~IJ~ FIVE (5) OHMS. ~ NOT~: ' I [ I'; GROUND RING , INSPECTION HAND HOLE MAY ~-." NOTE: ' · t ~ AWG ~-~2/0 BE PRE CAST CONCRETE OR PVC AND SHALL BE A MINIMUM 1.ALL METALLIC OBJECTS LOCATED WITHIN ~ /~ /' r~L---~MASTER OF 12" J BONDED TO THE GROUND RING. OONDUIT FROM SHARP MATERIAL FOR INDIVIDUAL CABLES ~ 2 AWG SOUD TINNED BCW TEST J LOOP CAB-WELDED TO E(;R.~ J '" c.~S. ~ROWDE i~S GROUND AB-WELDED TO E(;R. . CONDUCTORS WITH I~VO-HOLE TOGETHER. NOTE: CLEAN ALL GROUND WIRES (;ND&TELCO ~ L~ ARE ~2 AWG GREEN RING ~/2 AW(; SOLID TINNED -- ALL GROUND WIRES ARE 1~2 UNLESS NOTED I MISC. METAL I ~ ~ ~--NEW Egll ~mmmm m NO~: o' ,' ~* ~'.' ~' ~* ^W(; GREEN ,NSULATED. OTHERW,SE. /f~ I I GPS UN,T ./~ GROUND ROD ,F TH,S SHEET ,S ~' X ~' REEER ~ T,NNED UNLESS NOTED b 9~&~_ J ~T~ TO ABJADENT GRAPHIC SCALE. ~,~=,.-~ OTHERWISE. NEW L~~ L. LSUPPRESSO~jI I '"~v~"/ ~: ~ ,~': ,.-o. TEST WELL GPS UN~ ~ ~S AWG ~ ~ i./,/----(;ROUND ROD COPPER WELD ~ ~ _ 5/8" X 10'-0' LONG GROUNDING PLAN TYP. GROUNDING SCHEMATIC ~ ~'~ .......... ~~,~,,? ..... o....'r.,,'r....,,..s,',,u.,,.'r -'-- .......... t r :~' ::~ -lNG t R TELCO, ELEC. GROUNDING PLAN A R C ~1 I T I" C T $~ L L P NY7320 ~ ~/~.~ ,s~ ,o, r=..st~.~,~ ~" ~' . AND DETAILS ATAT MOBILITY ~ ./1,/~ ............. '~ ~ * 6 5 4 '~ ,~ 2 ~.=s~,[*e°,o=] ~,~ SIZE NEWTON iNSTRUMENT COMPANY, iNC. BUTNER, N.C. NO. REO, PART NO. DESCRIPTION (~ I 1/4"x4-*x3G" SOLID GND. BAR (~ 2 A-605§ WALL MTG. BRAT. (~ 2 3061-4 INSULATORS (~) 4 5012-1 5/E'-11x1" H.H.C,S, (~) 4 3015-8 5/8 LOCK'WASHER ~6 AWG STRANDED Cu ~ EACH GROUND CONDUCTOR TERMINATING ON ANY GROUND BAR SHALL HAVE WIRE WITH GREEN, 600V, ~ NEWTON iNSTRUMENT COMPANY, iNC. AN IDENTIFICATION TAG ATrACHED AT EACH END THAT WILL IDENTIFY ITS LOCKWASHER, ~,~FLAT WASHER, WP. THWN INSULATION BUTNER, N.C. ORIGIN AND DESTINATION. \~ (~) I 1/4"x4-'x30' SOLID GND. BAR CABLE ENTRY POETS (HATCH PLATES) l'~/O HOLE ON WALL, FLOOR COPPER ~ NLrf, WP.~ OR ON ANTENNA ] (~ 2 A-605§ WALL MTG. BRKT. GENERATOR FRAMEWORK (IF AVAILABLE) TERM,NAL @ = 306,-4 ,.SULATORS COMMERC~L POWER CO"MO" NE~-/GROU"D BOND ~ ~ +24V POWER SUPPLY B~URN BAR ~ ~LE~ TO AB~L~E @ © ~,e ~ © Oi co~ SUPPRESSION MINIMUM. NO ~ ~ SECTION "A" -- SURGE ABSORBERS GROUNDING INSULATION ALLOWED ~ ~_~ ~ ~ DOUBLE CRIMP CABLE ~ ' WI.IN THE L~ ,~~AN ~ ~ __ __ __ STRATE CONNECTION INTERIOR GROUND RING (,2) GLE SHOWN TO ILLU WELD GROUND RING METALUC COLD WATER PIPE (IF AVAILABLE) (~2) _TERMINAL,WP. EXOTHERMIC WE AT THE LOWEST POINT ON THE BAR BUILDING STEEL (IF AVAILABLE) (¢2) ELEVATION SECTION (WELDING PROHIBITED ~2 SECTION '(' ISOLATED GROUND ZONE ON ROOFTOPS) COPPER GROUND CONDUCTOR, ALL COMMUNICATIONS EQUIPMENT FRAMES. ~ EXOTHERMIC WELD TO BURIED GROUND ISOLATED GROUND BAR -- IGB RING AND GROUND BAR ~.// ~ p [ 'J..~.~;~..~-4 DETAIL NOTES: NOTES: ~'~~wEXE~HEEXOTHERMIC ~) EXOTHERMICALLY WELD #2 AWG BARE TINNED SOLID COPPER CONDUCTOR TO 1.'DOUBLING UP' OR "STACKING" OF CONNECTION IS NOT PERMITTED. RMIC 2. OXIDE INHIBITING COMPOUND TO BE USED AT ALL LOCATIONS. GROUND BAR, ROU~ CONDUCTOR TO BURIED GROUND RING AND PROVIDE PARALLEL EXOTHERMIC WELD. /'~.. GROUND BAR CONNECTION DETAIL A'~i~ INSTALLATION OF GROUND WlRE TO COAX CABLE GROUND BAR ~ RGB REFERENCE- GROUND BAR DETAIL ® USE PERMANENT MARKER TO DRAW THE LINES BEIWEEN EACH __ SECTION AND LABEL EACH SECTION ("F~. 'A". "¢') WITH 1' HIGH LETTERS. TO TOWER MOUNTED :NNA ~--ONLY FOR 1 TO ANTENNA~ : ~--GROUND BAR (CIGBE) COPPER BONDING CONDUCTOR RECEIVE ANTENNA ~T' ~O-NNECTION ('PfP.) ~~' TOP OF MONOPOLE BX~/RX2~2~ - _ LJ /SBx'/Rx~ ~. ,--W~*TH~RPROO.NG I I' I % %~ i~i /_ ~AND^RD ' BONDING BUSHING ANTENNA CABLE 12" TO 24" ~ ~ / I~1 / K~ APPBOVED EOHAL) ~ ~ ~ ~'% ~ ;~ ; / /--GROUND NIT CONDUIT S,ZE CO,DUCTOR (SEE NOTE 3) I.~fI~1 r_~.-IF NO~) W, RE WITH GREEN. 60 BONDING BUSHING~ k ~ ABLE BAR (~CIGBE) m~m ~ ~%7 TO aTS Bo-rr s scB. ,GAWGSTRANDEOCuW,REWITH i'll 1 CO. CABLE-- ' SEENOTE,. (RGS. 'MC, EMT, FLEX) ~ // #6RAWG STRANDED Cu SOLID TINNED AS COMPLETE UNIT. SUPPLIED OR RECOMMENDED BY CABLE MANUFACTURER.) i ~ GROUND WIRE TO GROUND BAR CONNECTION ~. NUMBER OF GROUND ~'~S ~ V~ OND GROUND US,INO DETA. CO,, C,lO, ......... ~~ ORIENT BY THE SEA RESTAURANT A "'/"~ ........ rP ,~/~.!~ F, ~:, t II NYCENY1059 /L1-1059 A '/"* ........ ~- I~ I~ m ~ ...... ' .......... ................... 40200 MAIN RD 15 EAST MID.ND AVENUE .......... I I ~' %~-- r ~--" I s,~¢ ......................... OR'ENT POINT, N.Y. 11957 PARAMUS. NJ 07652 ...... ........ ...... :%'~'~ ~897 NYCEN 059 E '