HomeMy WebLinkAbout35412-ZTown of Southold Annex
P.O. Box 1179
54375 Main Road
Southold, New York 11971
11/19/2012
CERTIFICATE OF OCCUPANCY
No: 36051
Date: 11/19/2012
THIS CERTIFIES that the building
Location of Property:
SCTM #: 473889
Subdivision:
OTHER
OREGON RD CUTCHOGUE,
Sec/Block/Lot: 83.-3-2.2
Filed Map No.
conforms substantially to the Application for Building Permit heretofore
3/24/2010 pursuant to which Building Permit No.
was issued, and conforms to all of the requirements of thc applicable provisions of the law. The occupancy for
which this certificate is issued is:
Lot No.
filed in this officed dated
35412 dated 3/24/2010
agricultural storage building as applied for.
The certificate is issued to
LIEB VINES LLC
(OWNER)
of the aforesaid building.
SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL
ELECTRICAL CERTIFICATE NO.
PLUMBERS CERTIFICATION DATED
FORM NO. 3
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
Town Hall
Southold, N.Y.
BUII/)ING PERMIT
(THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL
COMPLETION OF THE WORK AUTHORIZED)
PERMIT NO. 35412 Z Date MARCH 24, 2010
Permission is hereby granted to:
VINES LLC LIEB
14990 OREGON RO~iD
CUTCHOGUE,NY 11935
for :
CONSTRUCTION OF ~LN AGRICULTURAL STORAGE BUILDING PER PLAIqNING BD.
& LA/qD PRESERVATION AS APPLIED FOR
at premises located at OREGON RD
County Tax Map No. 473889 Section 083 Block
purs~t to application dated M3~RCH 24, 2010
Building Inspector to expire on SEPTEMBER 24,
CUTCHOGUE'
0003 Lot No. 002.002
and approved by the
2011.
Fee $ 150.00
Authorized Signature
ORIGINAL
Rev. 5/8/02
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
TOWN HALL
765-1802
APPLICATION FOR CERTIFICATE OF OCcUPANcy
This application must be f'flled in by typewriter or ink and submitted to the Building Department wi
A. For new building or new use: 1. Final survey 0fproperty with accurate location 0fall balldings~ property lines, streets, and
topographic features.
2. Final Approval from Health Dept. of water supply and sewerage-disposal (S_9 form).
3. Approval of electrical installation from Board 0f Fire Underwriters.
4. Sworn statement from plumber certifying that the solder used in systom contains less than
5. Commercial building, industrial building, multiple resideneas and similar buildings and insl
of Code Compliance from architect or engineer responsible for the building.
6, Submit Planning Board Approval of completed site plan requirements.
B. For existing buildings (prior to April 9, 1957) non-conforming uses, or buildings and "pre-existing" laud uses:
1. Accurate survey of property showing all property lines,'streets, building and unusual naturai or topographic
features'.
2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is
denied, the Building Inspector shall state the reasons therefor in writing to the applicant.
C. Fees
1. Certificate ofOceupancy - New dwelling $50.00, Additions to dwelling $50.00, Alterations to dwelling $50.00,
· Swimmilig poOl $50.00, Accessory building $50.00, Additions to accessory building $50.00 Businesses $50.0~Y.
2. Ce[tifieate of Occupancy on Pre-existing Building - $t00.00
3. Copy of Certificate of Occupancy - $ 25
4. Updated Certificate of Occupancy - $50.00
' 5. Temporary Certificate of Occupancy - Residential $15.00, Commercial $15.00
New Construction: ~ Old or Pre-existing Building:
Location ofProporty:, tq~.~ ~,~ ~
House No. Street
O orOw ofPro .y:
Suffolk County Tax Map No 1000, Section ~'~
Subdivisibn ~
Permit No. ~'~'{ )7_ .Date of Permit.
Health Dept. Approval: /g~4
Planning Board Approval:
Request for: Temporary Certificate
(check one)
Hamlet
]Jif____
uIo t Lot
Filed Map. _ ~ Lot: .----
Underwriters Approval: ~x.l.v/417-,
Final Certificate: J (check one)
(-~/~" A~']ic~lt ~g~ture
June 21, 2011
Mr. Michael Varity
Town of Southold Building Departmem
Southold, NY
Re: Lieb Vines LLC
Agricultural Storage Building
14990 Oregon Rd
Cutchogue, NY
MBI Job #128-0839
Dear Sirs:
I am writing to confirm and advise that the subject job has been completed in substantial
compliance to my drawings dated 12-11-2009, Enclosed is a stamped copy oftbe tress
that was used.
Please be further advised that I have confirmed that the wind bracing, strapping, roof and
wall connectors, and framing were installed per my plans.
Thank you.
Yours truly,
ALLIED DESIGN A&E GROUP, PC
JUL '' 2011
BLDG DEPZ
TOWI~ )F SOUTHOLD
SL 25-2-0
CROWN C,G 0-0-8 #11.25x11.25
,.o,2,
23-3-12
..**_-
Il
2090
~8 RC MN PLATE
23-9-12 47-9-0
24-:]-4
~obbins ~-gi~ering, Inc./Online Plusm
~=k Quan Ty~e Span P1-H1
0224811 z z3Rc 470900 4.042
Left OH Right OH S~g~Drawing J
0 0
:ob PLA TE ~..rk
2090 48 RC MN 0224811
Quan Type Span P1-H1 Left OH Right OH Engineering
I Z3RC 470900 4.042 0 0
Robbins Engineering, Inc./Online Plus~ APPEOX. TRUSS WEIGHT: 561.4 LBS
O -S2 0.57 12762 T 0.53 0.04 Q# ~20 2.5x 5.0 Ctr Cfr 0.60
S2-M 0.57 12766 T 0.53 0.04 H
Online Plue -- Version 20,0,025 M -K 0.47 10703 T 0.44 0.03 P ~20
K -J 0.47 10703 T 0.44 0.03 O# ~20
2090RC,0224~1t J -81 0.57 12766 T 0.53 0.04 S2 ~T8R
CSX -Siem ..... Lumber .... Sl-I 0,57 12761 T 0.53 0.04 M# ~0
TC 0.86 2x10 EP-2401 I -N 0.95 14319 T 0.59 0.36 K# MTSH
BC 0.95 2x 8 8P-2401 N -H 0.93 13742 T 0.57 0.36 J# ~20
WB 0.68 2x 4 SP-#I ............. W~bs ............. 81 MTSH
WG --- 2x 8 SP-#I B -P 0.00 I T I# MN20
Braoe trues as follows: C -O 0.21 1235 C
O.C. From To O -D 0.31 2018 T
TC 2- 0- 0 0- 0- 0 47- 9- 0 D -M 0.68 2260 C
BC 7- 6- 0 0- 0- 0 47- 9- 0 M -E 0.44 2825 T
K -E 0.28 1833 T
Loading Live Dead (psf) E -J 0.44 2825 T
TC 22.0 4.0 J -F 0.68 2260 C
BC 0.0 2.0 F -Z 0.31 2005 T
Total 22.0 6.0 28.0 I -G 0.21 1225 C
SRaoing 108.0" G -N 0.30 720 C
Lu~ber Duration Factor 1.15 N -Q 0.00 4 c
Plate Duration Faotor 1.15
TC Fb=l.00 FC=I.00 Ft=l.00 TL Defl -1.20" in M -L L/468
EC Fbml.00 Fc=l.00 Ft=l.00 LL Defl -0.94" in M -L L/597
Hz Diap LL DL TL
Jt React Uplft Size Req'd J~ H 0.43" 0.12" 0.55"
Lbs Lbs In-ex In-Ex Shear // Grain in A -B 0.67
A 6018 0 5- 8 5- 0
H 6017 0 5- 8 5- 0 Plates for each ply each face.
PLA~ING CONFO~4S TO TPI.
P~PORTS: ICC-ES ER-2929
Membr CSX P Lbs Axl-CSI-Bnd
.......... Top Chords .......... Plate - MN20 20 Ga, Gross Area
A -B 0.78 14752 C 0.29 0.49 Plate - ~18 20 Ga, Gross Area
E -C 0.85 14357 C 0.29 0.56 Plate - M~SH 20 Ga, Gross Area
C -D 0.48 14702 C 0.30 0.18
D -E 0.40 12732 C 0.22 0.18 Jt Type Plt Size X Y JSI
E -F 0.40 12731 C 0.22 0.18 A
P -G 0.48 14691 C 0.30 0.18 E# ~20 2.5x 5.0 Ctr Ctr 0.60
G -Q 0.85 14357 C 0.29 0.56 C# ~20 11.2x11.2-1.0 3.0 0.92
Q -H 0.78 14751 C 0.29 0.49 D~ ~N20 6.2x 8.8-1.0-1.0 0.76
........ Bottom Chords ......... Z# MN18 11.2x15.0 Ctr 0.4 0.83
A -P 0.93 13743 T 0.57 0.36 F# ~A~20 6.2x 8.8 1.0-1.0 0.76
P -O 0.95 14331 T 0.59 0.36 G# ~20 11.2x11.2 1.0 3.0 0.92
N [~q20
5. Ox 6.2 Ctr Ctr 0.50
6.2x 8.9 0.5 0.7 0.87
7.0x16.0 Ctr Ctr 0.96
9.8X 6.8 0,7 0.7 0,97
7.0x16.0 Ctr-0.2 0.80
8.8x 8.8-0.7 0.7 0.97
7.0x16.0 Ctr Ctr 0.96
6.2x 8.8-0.5 0.7 0.87
5. Ox 6.2 Ctr Cfr 0.50
Monitor used
~FgR TO ROBBINS ENG. G~NERA3~
NOT~SAh~0 SY~OLS SHEET FOR
ADDITIONA~ SPECIFICATIONS.
NOTES:
Trusses Manufactured by:
NOTE: USER ~4ODIFIED PLATES
This design may have plates
selected through a plate
monitor.
TOWN OF SOUTHOLD BUILDING DEPT.
765-1802
INSPECTION
[ ]FOUNDATION 1ST
[ ]FOUNDATION 2ND
[ ]FRAMING / STRAPlqNG
[ ] ROUGHinG.
[ ] ~Ji:ATION
I//]~1=1 NAL
[ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION
DATE ~ INSPECTOR
Building Inspector
,PPLICATION FOR BUILDING PERMIT
Date
INSTRUCTIONS
BLDG. DEPT.
a. Thlfl~l$Iitilttil~lllUST be ct npletely filled in by typewriter or in ink and submitted to thc Building Inspector with 4
sets of plans, accurate plot plan to scale. Fee according to schedule.
b. Plol plan showing location oflnt and of buildings on premises, relationship to adjoining premises or public streets or
areas, and waterways.
c. The work covered by this application may not be commenced before issuance of Building Permit.
d. Upon approval of this application, the Building Inspector will issue a Building Permit to the applicant. Such a permit
shall be kept on the premises available Ibr inspection throughout thc work.
e. No building shall be occupied or used in whole or in part for any purpose what so ever until thc Building Inspector
issues a Certificate of Occupancy.
f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of
issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the
property have been enacted in the interim, the Building Inspector may authorize, in writing, the extension of thc permit for an
addition six months. Thereafter, a new permit shall be required.
APPLICATION IS HEREBY MADE to the Building Department tbr the issuance ora Building Permit pursuant to thc
Building Zone Ordinance of the Town of Southold, Suffolk County, New York, and other applicable Laws, Ordinances or
Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The
applicant agrees to comply with all applicable laws, ordinances, building code,. ~ /-.~ -h°using cod~, and regulations, and to admit
authorized inspectors on premises and in building for necessary inspections~
~/' { S~4ff~tl~-e oyapplicant or name, if a c. erporation)
(Mailing addres.q of applicant)
State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder
Name ofownerofpremises [ ,.-T'~_,,,~ ~ ~tt ~.
(As on the tax roll or latest deed)
It' appli~rized officer
Builders Li~enseSo. l~7/~
Plumbers License No.
Electricians License No.
Other Trade's License No. r....
1. Location of land on which oro~s~ work will be done:
House Number Street
County Tax Map No. 1000 Section
Subdivision
(Name)
Hamlet
Block ~
Filed Map No..--
Lot ~
2. State existing use and occupancy of premises and intended use . .
a Ex sting USe and occupancy ~ ~d occupancy of propesed eonsmlet~on.
3. Nature of work (check which applicable): New Building~.~ Addition
Repair .Removal -- _Alteration
t~~r..~ _Demolition _Other Work
4. Estimated Cos Fee (D~-'fiption)
It dwelling, number ofdwellfllg units ~) ..... (To be paid on filing this application)
If garage, number of cars ~ er et dwelling Umts on each floeL
6. If bus/ness, COmmercial or mixed occupancy, specify nature and extent of each type of use.
7. ,D,i~e, nsions ofexi.stipg~tructurcs, if any: Front ~ Rear ~,~- _Depth
height___ ,ft,,j, ~ Number of St6ries ~
Dimensions of s~a[pe structure with alterations or dditions: Front ~- R ar
Depth ~ Hela,t J~ ~°ns: FNumber °t Stories ~l,~
8. ~Di....m..e.n.s,ons oren~ ,new construct on: Front /0 a '
I0 D ' - Depth_~4_ t
11. Zone or use district in which premises are situated ~
12. DTes proposed construction violate any zoning law. ordinan~ or regu ationV YES NO_4~
13 Wtll lot be re graded? YES__ NO. will excess fill be removed from premises?%S NO
14. Names of Owner ofp~a~'nises
Name of Architect ~,/,~-~ t, ,-, Address
15 a. Is this property within 100 feet ora tidal w
* iF YES, SOUTHOLD T WN T~t l ..... etland or a freshwater wetland? *YES
b Isths o rt w' . O ..... o~tz~;&D.E.C. PERMiTSMAyB NO~h~-
· pr po y tthm 300 feet ora tid.l w,~ a9 · . IJ~ REQUIRED~,
16, Provide survey, to scale, with accurate foundation plan and distances to property lines.
17, If elevation at any point on property is at 10 feet or below, must provide topographical data on survey.
STATE. OF NEW YORK)
SS:
(Name of ind__, g du y sworn, deposes and says that (s}h¢ is the applicant
(C°ntra~-~tt, Corporate (~ClCer etc¥-~
of ~aid owner or owners, and is du y authorized Io
thal all statements con aincd in flfi am~lle -' Pcrforrnorhavepeffortrled hesaidwor .
pcrtbnned n {1:~'~. .......... ~ ..r-.-auotl are lrtle to the best of his knowloa~^ ~ ,or,k,a~nd th make and file this application.
/~- ,'~,~ s~t .)rtn tn the application filed therewith. ~ anu ocfle[; arid that the work will be '
Sworn to e th
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
TOWN HALL
SOUTHOLD, NY 11971
TEL: (631) 765-1802
FAX: (631) 765-9502
SoutholdTown.North Fork.net
Examined ,20
Approved
Disapproved a/c
,20
Expiration ,20
PERMIT NO.
BUILDING PERMIT APPLICATION CHECKLIST
Do you have or need the following, before applying'?
Board of Health
4 sets of Building Plans
Plaiming Board approval
Survey
Check
Septic Form
N.Y.S.D.E.C.
Trustees
Flood Permit
Storm-Water Assessment Form
Contact:
Mail to:
Building Inspector
~~¢ Date ~' ~ ~) "- ,20~I
INSTRUCTIONS
~p~ar~s~h~oY~UST be ct mpletely filled in by typewrite,' or in mk and submitted to the Building Inspector with4
set: fplans, . r--- r,aa ,,~ ~a Fee according to schedule.
b. Plot plan showing location of lot and of buildings on premises, relationship to adjoining premises or public streets or
areas, and waterways.
c. The work covered by this application may not be commenced before issuance of Building Permit.
d. Upon approval of this application, the Building Inspector will issue a Building Permit to the applicant. Such a permit
shall be kept on the premises available for inspection throughout the work.
e. No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector
issues a Certificate of Occupancy.
f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of
issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the
property have been enacted in the interim, the Building Inspector may authorize, in writing, the extension of the permit for an
addition six months. Thereafter, a new permit shall be required.
APPLICATION IS HEREBY MADE to the Building Depamnent for the issuance of a Building Permit pursuant to the
Building Zone Ordinance of the Town of Southold, Suffolk County, New York, and other applicable Laws, Ordinances or
Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The
applicant agrees to comply with all applicable laws, ordinances, building code, housing code, aj~t regulations, and to admit
authorized inspectors on premises and in building for necessary inspections. /~~
(Mai'ling a~Idress of applicant)
State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder
Name of owner of premises
(As on the tax roll or latest deed)
If applicant is a corpo~ized officer
f corporate officer)
Builders License No. I :~ :~7~ ~
Plumbers License No. ,
Electricians License No~ ~
Other Trade's License No. ~
1. Location of land on which proposed work will be done:
House Number Street
Hamlet
County Tax Map No. 1000 Section~Block
Subdivision Filed Map No.
Lot ~, '~:? ,-
Lot
State existing use and occupancy of premises and intended use and occupancy of proposed construction:
a. Existing use and occupancy ~.~.~__ ._~-'>'~_,~P~t~,~..-,
b. lntended useandoccupancy ~_4~ ~Y'/t~
Nature
of work (check which applicable): New Building ~x_ Addition
Repair Removal Demolition ~ Other Work
Estimated Cost
Fee
Alteration X
(Description)
(To be paid on filing this application)
If dwelling, number of dwelling units/~umber of dwelling units on each floor -
If garage, number of cars
6. If business, commercial or mixed occupancy, specify nature and extent of each type of use.
7. Dimensions of existi g structures, if any: Front a,~/. ~.) ,. Rear q~ Depth
Height ~-~' Number of Stories 42~
Dimensions of same structure with alterations er additions: Front ~ Rear
Depth /6r'~~ Height Z-~4 Number of Stories 4'~
8. Dimensions of entire new construction: Front ~ _Depth
Height N~
9. Sizeoflot: Front ~ Rear _'~:,g-~ Depth / i["7fi'4/
10. DateofPurchase l' Z4-O0 NmneofFormerOwner ~V,-/~
11. Zone or use district in which premises are situated A ~
12. Does proposed construction violate any zoning law, ordinance or regulation? YES NO ~
13. Will lot be re-graded? YES NO /~ Will excess fill be removed from premises? YES NO_~r
14. Names of Owner of premises /.-~--'~'7 Vf/A-~'~ Address ~,~~D~,.- Phone No.~-~,2~'-~~'~
Name of Architect ~/~t :f~ Address~J..)~ one No 7~-4 -z~>{~O
Name of Contractor t~'l~'"/~/~ ~[~).MD~ Address ~L)~]~ffa~Phone No. ?-._"~"q ' '~2~---~
15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO ~
* IF YES, SOUTHOLD TOWN TRUSTEES & D.E.C. PERMITS MAY ,~REQUIRED.
b. Is this property within 300 feet ora tidal wetland? * YES NO
* IF YES, D.E.C. PERMITS MAY BE REQUIRED.
16. Provide survey, to scale, with accurate foundation plan and distances to property lines.
17. if elevation at any point on property is at 10 feet or below, must provide topographical data on survey.
18. Are there any covenants and restrictions with respect to this property? * YES NO V
· IF YES, PROVIDE A COPY.
STATE OF NEW YORK)
SS:
COUNTY ova'oX--f,
~~ ~ being duly sworn, deposes and says that (s)he is the applicant
(Name of individual signing contract) above named,
(S)He is the
(Contractor, Agent, Corporate Officer, etc.)
of said owner or owners, and is duly authorized to pert'om or have performed the said work and to make and file this application;
that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be
perfrrrmed in the manner set forth in the application filed therewith.
Sworn to before me this~~ ~ t ~/
c~ day of '(h'XO,~-_..~ 20 if
'f~/""',~..~ '(~-~ ~'~'-~ VICKI TOTH
;qo/an, Pubiic State ¢ NewYo~
Notary Public NO, 01~06190696 ~atu~ ~pplicant
~ qualified in Suffolk O0un~ ~
?~ ~" ¢~ ~?~]~m July 28, ~
TOWN OF SOUTHOLD
FORM NO. 3
NOTICE OF DISAPPROVAL
DATE: January 11, 2010
To:
William Kelly for
Lieb Vines LLC
P O Box 1680
Southold, NY 11971
Please take notice that your application dated January 5, 2010
For permit to construct an agricultural storage building at
Location ofpropexty: 13050 Oregon Road, Cutchogue
County Tax Map No. 1000 - Section 83 Block 3 Lot 2.2
Is returned herewith and disapproved on the following grounds:
Pursuant to Article XXIV, Section 280-127, the proposed agricultural storage building requires
Site Plan approval from the Southold Town Planning Board.
[ Authorized Signature
CC: file, Planning Bd.
Note to Applicant: Any change or deviation to the above referenced application, may require
further review by the Southold Town Building Department.
· PLANNING BOARD MEMBERS
MARTIN H. SIDOR
Chair
WILLIAM J. CREMEP~
KENNETH L. EDWARDS
JOSEPH L. TOV~NSEND
DONALD J. WILCENSKI
PLANNING BOARD OFFICE
TOWN OF SOUTHOLD
MAII~NG ADDRESS:
P.O. Box 1179
Southold, NY 11971
O~'FICE LOCATION:
Town Hall Annex
54375 State Route 25
(cor. Main Rd. & Youngs Ave.)
Southold, NY
Telephone: 631 765-1938
Fax: 631 765-3136
March 23, 2010
Mr. William Kelly
P.O. Box 1680
Southold, NY 11971
Re:
Approval: Proposed Site Plan for Agricultural Storage Building/Lieb Vines LLC
Location: 13050 Oregon Road, Cutchogue NY
SCTM#1000- 83-3-2.2 Zoning District: A-C
Dear Mr. Kelly:
The following resolutions were adopted at a meeting of the Southold Town Planning Board on
March 22, 2010:
WHEREAS, this site plan is proposing to construct a 5,040 sq. ft. agricultural storage building
measuring 105' x 48', for storage of farm equipment related to growing grape vines and
harvesting grapes on 13.7 acres with Development Rights sold in the A-C Zoning District. There
is one other existing storage building on site which is 48.3' x 115.2', south of Oregon Road .and
approximately 250' feet east of Cox Lane, and 540 feet southeast of the proposed new building;
and
WHEREAS, the applicant submitted an application for site plan review on February 8, 2010; and
WHEREAS, the Southold Town Planning Board accepted the application for formal review at
their February 16, 2010 Work Session; and
WHEREAS, the Southold Town Planning Board pursuant to State Environmental Quality
Review (SEQR) (6 NYCRR, Part 617.5 (c) (3) has determined that the proposed action is a
Type II Action as it falls within the following description for (6 NYCRR, Part 617.5 (c) (3)
"agricultural farm management practices, including construction...of farm buildings and
structures..." and not subject to review under SEQRA; and
WHEREAS, on February 18, 2010, the Southold Town Architectural Review Committee
reviewed and determined that the proposed agricultural storage building was acceptable; and
WHEREAS, on February 26, 2010, the Planning Board, pursuant to Southold Town Code {}280-
131 C., distributed the application to the required agencies for their comments; and
WHEREAS, on February 26, 2010, the Southold Town Engineer reviewed the above-referenced
application and has determined the project to provide adequate drainage and the proposed
drainage meets the minimum requirements of Chapter 236 for Storm Water Management; and
Lieb Vines, LLC Pa,qe Two
March 23, 2010
WHEREAS, on March 1, 2010, the Town of Southold LWRP Coordinator reviewed the above-
referenced project and has recommended that the proposed project is consistent with Southold
Town LWRP policies; and
WHEREAS, on March 8 2010, the Southold Town Chief Building Inspector reviewed and
certified the proposed site plan as a peh~itted use in the A-ClR-80 Zoning Districts; and
WHEREAS, on March 9, 2010, the Cutchogue Fire Distdct requested that provisions be made
for emergency vehicle access to the proposed bam and requested that the road be able to
support a Class A engine (minimum 70,000 pounds) and determined that water supply in the
area was adequate for the site; and
WHEREAS, on March 18, 2010, the applicant made a note on the site plan map indicating that
an RCA base will be placed upon the farm road that would support a Class A fire engine; and
WHEREAS, the Southold Town Planning Board, pursuant to §280-131 H of the Southold Town
Code, has the discretion to waive the public hearing requirement for those applications involving
uses strictly related to agriculture; and
WHEREAS, the Southold Town Planning Board has found that the public hearing for this
application may be waived for the following reasons: this site is an already active farm
operation, the location and topography of the additions and new building is such that it will
conform with other structures on the property which are already actively being used for
agricultural purposes, the adjacent parcels to the northeast and south are active agricultural
operations and the residential lot immediately adjacent to the proposed agricultural storage
building to the west is a heavily wooded lot and the proposed structure is over 170 feet from the
residential structUre on the adjacent lot; and
WHEREAS, the Southold Town Planning Board, pursuant to §280-133 C of the $outhold Town
Code, has the discretion to waive any or all of the requirements in §280-133 for those
applications involving uses strictly related to agriculture as long as they are not necessary to
further the objectives set forth in Town Code §280-129 to maintain public health, safety, and
welfare; and
WHEREAS, pursuant to Southold Town Code §280-133 C, the Planning Board has found that
requiring the entire set of site plan application requirements for this site is not necessary for the
following reasons: the application is for an agricultural use and part of an active farm operation,
and the parcel is large in size relative to the proposed and ~xisting structures (the structures
cover only 1.89% of the farm area), therefore, the Planning Board will require only the following
site plan application items:
§280-133 A. (1) and (2), B. (1)(a -f), B. 3(a) and B. 4(a) and (i); and
WHEREAS, the Southold Town Planning Board, pursuant to Southold Town Code {}280-131 B
(5), has the discretion to vary or waive the parking requirements for site plan applications where
doing so would not have a detrimental effect on the public health, safety or general welfare, and
will not have the effect of nullifying the intent and provision of the Site Plan Requirements
chapter of the Town Code. The Planning Board has found that this application is eligible for a
waiver of parking requirements because there is no need to provide for parking - the barn is
being used to house only related to growing grape vines and harvesting grapes where space for
the parking of farm vehicles is ample, and there will be no public access to the barn; and
Lieb Vines, LLC Pa,qe Three
March 23, 2010
WHEREAS, all applicable requirements of the Site Plan Regulations Article XXIV, {}280 - Site
Plan Approval of the Town of Southold have been met; be it therefore
RESOLVED, that the Southold Town Planning Board hereby waives the public hearing
requirement, the parking requirements, and site plan application requirements, as noted above;
and be it further
RESOLVED, that the Southold Town Planning Board has determined that this proposed action
is consistent with the policies of the Town of Southold Loca Waterfront Rev ta zation Program;
and be it further
RESOLVED, that the Southold Town Planning Board grants ApProval to the site plan entitled
"Lieb Vines, LLC", prepared by Nathan Taft Corwin, III, Land Surveyor, on October 1, 1999 and
last revised on October 9, 2009 and authorizes the Chairman to endorse the site plan.
Please also note the following requirements in the Southold Town Code relating to site plans:
1) Any outdoor lighting shall be shielded so the light source is not visible from adjacent
properties and roadways. Lighting fixtures shall focus and direct the light in such a
manner as to contain the light and glare within property boundaries.
2) All storm water run-off from grading, driveways and gravel areas must be contained on
site.
3) Approved site plans are valid for three years from the date of approval, within which time
all proposed work must be completed, unless the Planning Board grants an extension.
4) Any changes from the approved site plan shall require Planning Board approval.
5) Prior to the issuance of a Certificate of Occupancy, the Planning Board must inspect the
site to ensure it is in conformity with the approved site plan, and issue a final site
inspection approval letter. Should the site be found not in conformance with the
approved site plan, no Certificate of Occupancy may be issued unless the Planning
' Board approves the changes to the plan.
A copy of the approved site plan is enclosed for your records. One copy will also be sent to the
Building Department and the Town Engineer/Highway Department.
If you have any questions regarding the above, please contact this office.
Very truly yours,
Martin H. Sidor
Chairman
Encl.
CC;
Building Dept. w/map
Town Engineer w/map
PLANNING BOARD MEMBERS
DONALD J. WILCENSKI
Chair
WILLIAM J. CREMERS
KENNETH L. EDWARDS
JAMES H. RICH III
MARTIN H. SIDOR
PLANNING BOARD OFFICE
TOWN OF SOUTHOLD
MAILING ADDRESS:
P.O. Box 1179
Southold, NY 11971
OFFICE LOCATION:
Town Hail Annex
54375 State Route 25
(cor. Main Rd. & Youngs Ave.)
Southold, NY
Telephone: 631 765-1938
Fax: 631 765-3136
November 15, 2012
Mr. Bill Kelly
Morton Buildings, Inc.
22355 Cox Lane, Unit #4
Cutchogue, NY 11935
Re:
Approved Site Plan for Lieb Vines, LLC
Located at 13050 Oregon Road, Cutchogue
SCTM#1000-83-3-2.2 Zoning District: A-C
Dear Mr. Kelly:
The Planning Board, at their November 8, 2012 Work Session, found that the
requirements of the above-referenced site plan have been completed based on the site
inspection made November 5, 2012. The site is now in conformance with the approved
site plan dated October 1, 1999, prepared by Nathan Taft Corwin, III, last revised
October 30, 2009.
This letter does not condone any changes from the approved site plan and approvals
from other agencies; Planning Board approval is required pdor to any significant
changes to the site.
Please, if you have any questions regarding this site plan or its process, do not hesitate
to call this office.
Very truly yours,
Donald J. Wilcenski
Chairman
CC:
Planning Board
Heather Lanza, Planning Director
Michael Verity, Chief Building Inspector
Jamie Richter, Town Engineer
'~ MELISSA A. SPIRO
LAND PRESERVATION COORDINATOR
melissa.spim @ town.southold.ny.us
Telephone (631 ) 765-5711
Facsimile (631) 765-6640
OFFICE LOCATION:
Town Hall Annex
54375 State Route 25
(comer of Main Road & Youngs Avenue)
Southold, New York
MAILING ADDRESS:
P.O. Box 1179
Southold, NY 11971-0959
DEPARTMENT OF LAND PRESERVATION
TOWN OF SOUTHOLD
December 1, 2009
Lieb Vineyards, LLC
Attention: Bill Kelly
P.O. Box 1680
Southold, NY 11971
RE:
SCTM # 1000-83.-3-2,2
LIEB VINEST LLC Property
Request for Land Preservation Committee Review of
proposed agricultural equipment storage building on property on
which Town owns a development rights easement
Dear Mr. Kelly:
The Land Preservation Committee Members, in accordance with Section
70-5 C. (2) [3] of the Town Code, reviewed the request you outlined in an
application dated November 11, 2009, for an agricultural equipment storage
building.
The recorded easement for this property allows land within the easement
to be used for the purpose of agricultural production. Section 70-5-C. (2) [3]
requires that the Committee serve as a review board for the granting of permits
for the' construction, reconstruction and additions of and to structures in or on
agricultural lands in which the development rights have been acquired by the
Town.
The Committee is approving the use you requested, as listed and clarified
below, to be allowed within the development rights easement area. The
Committee's approval does not mean that you can proceed with construction. All
improvements are subject to all applicable Town Code requirements.
1. Construction of a 48'x105' Morton Style building to be located in the
southwesterly corner of the property (30' from westerly property line, or at
the minimum setback required by Code), at a depth of about 800' south
from Oregon Road.
2. Building use is to be for the storage of farm equipment used in the
vineyard such as nets, tractors, mowers, and harvesting equipment.
Please note that the Committee's approval of the uses within the
easement does not mean that such uses will be approved or permitted by other
Town Departments or agencies. The Committee's approval allows you to
proceed with pursuing any applicable approvals that are required by Town Code.
Please feel free to call me if you have any questions regarding the above.
Sincerely,~ ~.
Melissa Spiro
Land Preservation Coordinator
encs: landowner's application & survey showing proposed location
cc: Planning Department w/landowner's application & survey
Building Department w/landowner's application & survey
MELISSA A. SPIRO
LAND PRESERVATION COORDINATOR
melissa.spiro @ town.southold.ny.us
Telephone (631) 765-5711
Facsimile (631) 765-6640
OFFICE LOCATION:
Town Hall Annex
54375 State Route 25
(comer of Main Road & Youngs Avenue)
Southold, New York
MAILING ADDRESS:
P.O. Box 1179
Southold, NY 11971-0959
DEPARTMENT OF LAND PRESERVATION
TOWN OF SOUTHOLD
December 1,2009
Lieb Vineyards, LLC
Attention: Bill Kelly
P.O. Box 1680
Southold, NY 11971
RE:
SCTM # 1000-83.-3-2.2
LIEB VINES, LLC Property
Request for Land Preservation Committee Review of
proposed agricultural equipment storage building on property on
which Town owns a development rights easement
Dear Mr. Kelly:
The Land Preservation Committee Members, in accordance with Section
70-5 C. (2) [3] of the Town Code, reviewed the request you outlined in an
application dated November 11, 2009, for an agricultural equipment storage
building.
The recorded easement for this property allows land within the easement
to be used for the purpose of agricultural production. Section 70-5-C. (2) [3]
requires that the Committee serve as a review board for the granting of permits
for the construction, reconstruction and additions of and to structures in or on
agricultural lands in which the development rights have been acquired by the
Town.
The Committee is approving the use you requested, as listed and clarified
below, to be allowed within the development rights easement area. The
Committee's approval does not mean that you can proceed with construction. All
improvements are subject to all applicable Town Code requirements.
Construction of a 48'x105' Morton Style building to be located in the
southwesterly corner of the property (30' from westerly property line, or at
the minimum setback required by Code), at a depth of about 800' south
from Oregon Road.
2. Building use is to be for the storage of farm equipment used in the
vineyard such as nets, tractors, mowers, and harvesting equipment.
Please note that the Committee's approval of the uses within the
easement does not mean that such uses will be approved or permitted by other
Town Departments or agencies. The Committee's approval allows you to
proceed with pursuing any applicable approvals that are required by Town Code.
Please feel free to call me if you have any questions regarding the above.
Sincerely,~ ~.
Melissa Spiro
Land Preservation Coordinator
encs: landowner's application & survey showing proposed location
cc: Planning Department w/landowner's application & survey
Building Department w/landowner's application & survey
o_ f Southold
Erosion, Sedimentation & Storm-Water Run-off ASSESSMENT FORM
P,R, OPERTY LOCATION: ._~S.C.T.M. #: .~ THE FOLLOWING ACTION8 MAY REQUIRE THE 8UBI~J~GI'''~u OF A
~ ~"'~ ~ ~,/--- .8't~RM-WATER, GRADING, DRAINAGE AND EROSION ~-N-.~.~L pL~.M
Dlsbtct ~ ~ ~ ~G~.~ ,r,ED BY A DESIGN PROFE8810NAL IN THE STATE OF NEW YORK.
Item Number: (NOTE: A Check Mark (~) for each Question is Required for a Complele Application)
Yes No
I Will this Project Retain All Storm-Water Run-Off Generated by a Two (2") Inch Rainfall on Site?
(This item will include all ten-off created by site clearing and/or construction activities as wall as all Site
Improvements and the permanent creation of impervious surfaces.)
2 Does the Site Plan and/or Survey Show NI Proposed Drainage Sfll,'ctures Indicating Size & Location?
This Item shall include all Proposed Grade Changes and Slopes Ccatrctling Surface WatarFIowi
3 Will this Project Require any Land Filling, Grading or Excavation where there is a change IQ the Natural
Existing Grade Involving more than 200 Cubic Ya~s of Matedal within any Parcel?
4 Will this Application Require Land Disturbing Activities Encompassing an Area in Excess of
Five Thousand ($,000) Square Feet of Ground SurPace?
5 Is there a Natural Waler Course Running through the Site?
Is this Project within the Trustees jurisdiction or within One Hundred (100') feet of a Wetland or Beach?
6 Will there be Site preparation on Existing Grade Slopes which Exceed Fifteen (15) feet of Vertical Rise t(
One Hundred (100') of Horizontal Distance?
7 Will Ddvaways, Parking Areas or other Impendous Surfaces be Sloped to Direct Stom~-Water Run-Off
into and/or in the direction of a Town tight-of-way?
8 Will this Project Require the Placement of Material, Removal of Vegetation and/or the ConstmcUon of
any Item Within the Town Right-of-Way or Road Shoulder Area?
(This item will NOT Include the Installation of DHveway Aprons.)
9 Will this Project Require Site Preparation within the One Hundred (100) Year Floodplain of any Watercour
NOTE: If Any Answer to Queetlons One through Nine la Answered with a Check Mark In the Box, a Storm-~, ~r, Grading,
Draina._ge &_.Er_eel__°n._C°._nt._ml._Plan. I_s_.Requl__mdand._Mu._st~be_.SuJ21ffJdJo~R~vl~wJHJrJoJasJaJ~ _ofA._ny_.EullcI ~ P.._e_mfit/
EXEMPTION: ~ Yes
Does this project meet the minimum standards for classification as an Agricultural Prelect?
Note: If You Answered Yes to this Question, a Storm-Water, Grading, Drainage & Erosion Control Plan is NOT Requlredl" ~
STATE OF NEW YORK, N0ta~/Public, State of New York
COUNTY OF ....~.....~...~ ......... SS No. 01BU6~85050
Qualified in Suffo k County
That I, ...~'.S~.A~......~......... ~1 . being duly swom, de'poses and says Commission Expires April 14, 20~i~
rtat he/abe is d]¢ applicant for
(Name of individual signing Document)
.... . ..........................................
m~e md file ~s application; ~at ~1 s~temen~ con~ed in ~h application ~e to ~e ~
&at ~e work mil be peffo~ed in ~e nmner set fo~ in ~e application filed hc~m~. HON~ 'fl 3~OT
Sworn to ~fom me ~is;
...............................................~~daY o~~~ ~ ~ ............ g0.[.~
Nom~ Public: ..~.~.f..2 ............ ~...~.~ .................... . ...............
FORM - 06107
~ o~-~z-z- - ..... OF SOUTHOLD PROPERTY RECORD CARD
· OWNER
~ VL
TOTAL DATE
AGE
T~PE OF I~IILDING ..
· :3 . ti
¢o~. cB. ~c$. ~t. wi~.
P~EMARr, S
NEW
'131lab[e
Woodland
Meab'ow~ond
House Plot
Total
NOR,~. L
Acre
BUILDING COND T ON
BELOW ABOVE
VaJue Per V~lue
/ 1/
FRONTAGE ON ROAD
DEPTH. ·
BULKHEAD
DOCK
· ~ ~ra Quan ~ Span P1-H1 Left OH Right OH ] Single Drawing
2090 48'RC MN PLATE 0224811 1 Z3RC 470900 4.042 0 0
I
2090 ~ PLA TE ..=k Quan T~pe Span Pl-H1 Left OH Right OH Engin£e.ng
48 RC MN 0224811 i z3Rc 470900 4.042 0 0
Robbing Engineering, Inc./0nline Plus~ APPROX.
O -32 0.57 12762 T 0.53 0.04 Q# ~q20 2.5x 5.0 Ctr Ctr 0.60
S2-M 0.57 12766 T 0.53 0.04 H UN18 11.3X12,5 1.00
Online Plus -- Version 20.0.025 M -K 0.47 10703 T 0.44 0.03 H MN18 8.8x16.3 0.94
K -J 0.47 10703 T 0.44 0.03 P l~q20 5.0x 6.2 Ctr Ctr 0.50
2090R~0~4~1t J -S1 0.57 12766 T 0.53 0.04 O#~20 6.2x 8.8 0.5 0.7 0.67
CSI -Size ..... Lumber .... Si-I 0.57 12761 T 0.53 0.04 S2 MTaH 7.0x16.0 Ctr Ctr 0.96
TC 0.85 2x10 SP-2401 I -N 0.95 14319 T 0.59 0.36 M# )~T20 8.8x 8.8 0.7 0.7 0.97
BC 0.95 2x 8 SP-2401 N -E 0.93 13742 T 0.57 0.36 K# MT8H 7.0x16.0 Ctr-0.2 0.80
WB 0.68 2x 4 SP-#i ............. webs ............. J# MN20 8.8x 8.8-0.7 0.7 0.97
WG --- 2x 8 SP-#1 B -P 0.00 I T S1 MTaH 7.0x16.0 Cfr Ctr 0.96
P -C 0.31 731 C I# ~q20 6.2x 8.8-0.5 8.7 0.87
Brace truss as follows: C -O 0.21 1235 C N l~q20 5.0x 6.2 Ctr Ctr 0.50
C.C. From To O -D 0.31 2018 T # = Plate Monitor used
TC 2- 0- 0 0- 0- 0 47- 9- 0 D -M 0.68 2260 C
BC 7- 6- 0 0- 0- 0 47- 9- 0 M -E 0.44 2825 T
Loading Live Dead (psf)
TC 22.0 4.0
BC 0.0 2.0
Total 22.0 6.0 28.0
Spacing 108.0"
~er Duration Factor 1.15
Plate Duration Factor 1.15
TC Fb=l.00 Fc=l.00 Ft=l.00
BC Fb=l.00 FC=i.00 Ft=l.00
K -E 0.28 1833 T
E -J 0.44 2825 T
J -F 0.68 2260 C
F -I 0.31 2005 T
I -G 0.21 1225 C
G -N 0.30 720 C
N -Q 0.00 4 C
TL DeE1 -1.20" in M -L
Hz Disp LL DL
Jt H 0.43" 0.12"
Shear // Grain in A -B
Jt React Uplft Size Req'd
Lbs Lbs In-Sx In-Sx
A 6016 0 5- 8 5- 0
H 6017 0 5- 8 5- 0
Plates for each ply each
PLA~ING CONFOP/~S TO TPI.
BEPORTS: ICC-ES ER-2929
~"~hr CSI P Lbs Axl-CSI-Bnd
P~FER TO ROBINS ENG. GENERAL
NOTES AND S~MBOLS S~ET FOR
ADDITIONAL SPECIFICATIONS.
.......... Top Chords .......... Plate - }~q20 20 Ga, Gross
A -B 0.78 14752 C 0.29 0.49 Plate - MN18 18 Ga, Gross
B -C 0.85 14357 C 0.29 0.56 ~late - MT8R 18 Ga, Gross
C -D 0.48 14702 C 0.30 0.18 Jt Type Plt Size X Y
D -E 0.40 12732 C 0.22 0.18 A ~N18 11.3X12.5
S -F 0.40 12731 C 0.22 0.18 A UN18 8.8x16.3
F -G 0.48 14691 C 0.30 0.18 B# ~20 2.5x 5.0 Cfr Cfr
G -Q 0.85 14357 C 0.29 0.56 C9 ~20 11.2x11.2-1.0 3.0
Q -H 0.78 14751 C 0.29 0.49 D# MN20 6.2x 8.8-1.0-1.0
........ Bottom Chords ......... E# MN18 11.2x15.0 Ctr 0.4
A -P 0.93 13743 T 0.57 0.36 F# MN20 6.2x 8.8 1.0-1.0
P -O 0.95 14331 T 0.59 0.36 G# MN20 11.2x11.2 1.0 3.0
NOTES:
Trusses Manufactured by:
Morton Buildings, Inc.
Analysis Conforms TO:
ANSI/TPI 95 & 02
L/468 Run vertical thru botto~cho~d
L/597 Joint K
TL Tr~ss is designed for no
0.55" ceiling load.
0.67 NOTE: USER MODIFIED PLATES
.oo
.oq
FOR: Lieb Vineyard inc.
Cutchogue, NY 11935
BUILDING USE: machine shed
BUILDING DESCRIPTION:
JOB # 128-0839
WIDTH .....................................
LENGTH ...................................
SIDE OVERHANG WIDTH .........
END OVERHANG WIDTH ..........
GRADE TO HEEL HEIGHT ........
ROOF SLOPE ..........................
BAY SPACING .........................
END BAY SPACING ..................
BUILDING VOLUME ..................
PEAK HEIGHT ..........................
BW := 48.fi
BL:= 75-ft
SOW :-- 1 .fi
EOW := l.fi
HH := 14.It
RS := 4/12
BS := 7.5-fl
EBS := 8-fi
BV = 70296 fl3
PH = 23.5 ~
DESIGN LOADS:
REFERENCED STANDARDS:
WIND SPEED .............................
EXPOSURE CATEGORY .............
ENCLOSURE CLA?,SIi"ICATION...
WIND IMPORTANCE FACTOR .....
V~ := 120 mph
EC := "B"
EnC := "ENCLOSED"
Iw := .77
GROUND SNOW LOAD .............
SNOW EXPOSURE FACTOR ....
SNOW IMPORTANCE FACTOR..
THERMAL FACTOR ..................
ROOF SURFACE .....................
pg := 20.psf
SEF := "P~tRTIALLY"
It := .8
C~ := 1.2
Surface := "SLIPPERY"
SLOPED ROOF SNOW LOAD
Ps := 0.7'Ce'ls'Pg'Ct'Cs
Ps 12.6.psf
MINIMUM ROOF LIVE LOAD
Lr:= 20.psf. Ri.R2
Lr; 16.8.psf
DESIGN LIVE LOAD ................... LL = 16.8'psf
DEAD LOAD ............................... DL := 4.psf
CEILING LOAD ...........................
ASCE 7-05
IBC 2006
NDS 2001
IZ- tl 9
~ge 1of 18
WIND CALCULATION:
W1
EH=I5.5fl,
BW = 48ft [
WIND DESIGN COEFFICIENTS:
WIND DIRECTIONALITY FACTOR .................................................. K,~ := 0.85
3-SECOND GUST SPEED POWER LAW EXPONENT ..................... a 7
NOMINAL HEIGHT OF THE ATMOSPHERIC BOUNDARY LAYER .... zo = 1200 ft
MEAN ROOF HEIGHT ................................................................... H = 19.527.12
HEIGHT ABOVE GROUND LEVEL (ASCE minimum) ....................... z - 3012
VELOCITY PRESSURE EXPOSURE COEFFICIENT ........................ Kz = 0.7
VELOCITY PRESSURE... q := 0.00256'Kz'Kd'V~s2.Iw. PSf q = 16.904.psf
EDGE STRIP WIDTH ....... ESW = 4.812
END ZONE WIDTH .......... EZW = 9.61t
INTERNAL PRESSURE COEFFICIENTS:
GCpi iN = -0.18
GCpi OUT: 0.18
EXTERNAL PRESSURE COEFFICIENTS - CASE A - TRANSVERSE LOADING'
END ZONES INTERIOR ZONES
GCp£A IE -- 0.78 GCpt-^ I = 0.516
GCp£A.2E = -1.07 GCp£A.2 = -0.69
GCp~^ 3E = -0.673 GCp£^ 3 = -0.469
GCpfA 4E = -0.618 GCpfA 4 = -0.415
GCpfA.SE = 0.78 GC-£A 5 = -0.45 }
GCp£A 6E -- -0.618 GCp£A 6 = -0.45
Page 2of38
MWFRS DESIGN PRESSURES - CASE A - TRANSVERSE LOADING:
END ZONES
PAIEI := q'(GCp£A.IE - gCpi IN)
PA2EI : q'(GCp£A 2E GCpi IN)
PA3E I := q'(GCpEA 3E - GCpi IN)
PA4EI:= q'(GCpEA4E- GCpi iN)
PASE. I := q'(GCpfA 5E - GCpilN)
PA6EI: q'(GCp£A 6E GCpi. IN)
PA IE1 - 16.23'psf
PA2EI = -15.044'psf
PA3Et = -8.339'psf
PA4EI = --7.405'psf
PASEI 16.23'psf
PA6EI = 7.405'psf
PA I E2 := q'(GCp£A 1E - GCpi OUT)
PA2E 2 :- q'(GCp£A 2E GCpi OU'I)
PA3E2 :- q'(GCp£A 3E - GCpi. OUI')
PA4E2 := q'(GCpl~^ 4E - GCpiOUT)
PA 5E2 :- q'(GCpfA 5E - GCpi OUr)
PA6E2 := q'(GCp£A6E - GCpiOUT)
INTERIOR ZONES
PA I I := q'(GCpfA I - GCpi IN)
PA21 := q'(GCpfA2 - GrpilN)
PA31 := q'(GCp/~A 3 - GCpi IN)
PA41: q'(GCpfA 4 GCpi IN)
PA 5 I : q'(GCp£A 5 GCpi.lN)
PA61 := q'(GCp£A6 - GCpilN)
PALE2 = 10.145.psf
PA.2E 2 = 21.129. psf
PA3E 2 = -14.424.psf
P^4E2 = --13.491 .psf
PA 5E2 = 10.145 psf
PA6E2 = -13.491.psf
PA I I - 11.772.psf
PA2 I -- -8.62I.psf
PA31 = 4.877.psf
PA 4 ~ = -3.979.psf
PA 5 I = -4.564.psf
PA61 = 4.564. psf
P^.l 2 := q'(GCpl~A.I - GCpi OUT)
PA.2.2 := q'(GCp£A 2 - GCpi OUT)
PA32 :-- q'(GCpfA3 GCpi OUT)
PA42 :: q'(GCp£A 4 - GCpi OUl)
PAS.2 := q'(GCpfA 5 - GCpiOUT)
PA62 :- q'(GCp£A 6 - GCpi OUT)
PA.I.2 = 5.687.psf
PA22 = -14.706.psf
PA32 = --10.962. psf
P^ 42 -- --10.064.psf
P^52 = --10.649.psf
PA 62 = --10.649. psf
z
Page 3of 18
"- "L'TZ: ,~ =
EXTERNAL PRESSURE COEFFICIENTS - COMPONENTS AND CLADDING'
GCpl = -0,9
GCp2 - -1.7
GCp3 = -2.6
GCp4 := -I.1
GCp5 := -1.4
COMPONENTS AND CLADDING DESIGN PRESSURES:
PCCII :- q'(GCpl GCpiIN)
PCC2.1 := q'(GCp2 - GCpi IN)
PCC31: q'(GCp3-GCpilN)
PCC41 := q'(GCp4 - GCpi IN)
PCC5 I := q'(GCp5 GCpi
PCCII =-12'171'psf
PCC2 I -25.693.psf
PCC3.1 = -40.906. psf
PCC41 -15.551.psf
PCC51 = -20.622-psf
PCCI2 := q'(GCpl - GCpi OUT)
PCC22 := q'(GCp2 - GCpi OUT)
PCC32 := q'(GCp3 - GCpiOUT)
PCC42 := q'(GCp4 - GCpi OUT)
PCC52 := q'(GCp5 - GCpi.OUT)
PCC]2 -18.256.psf
Pcc22= 31.779.psf
PCC32 = ~46.992.psf
PCC42 - -21.636.psf
PCC~2 = -26.708.psf
Page 4of 18
MAiN WINDFORCE-RESISTING SYSTEM:
END ZONE HORIZONTAL LOADS
PA Ewall = 23.636.psf
PA groof - 0.psf
INTERIOR ZONE HORIZONTAL LOADS
PA ~all- 15.751.psf
DIAPHRAGM PROPERTIES:
ROOF
Safet~Factor := 2.5 Duration_Factor: 1.33
Roof Material: 0.019 Hi-Rib Steel Ultimate_Shear := 177.plf
(Ultimate She /.Duration
Roof_Allowable Shear := ~ Safety Factor J _Factor
Roof Allowable Shear = 94.164- plf
WALL
Safety_Factor := 2.5 Duration Factor := 1,33
Wall Material: 0.019 Hi-Rib Steel Ultimate_Shear := 177,plf
/Ultimate Shear'~
Wall_Allowable_Shear := I ~ ~ .[.Duration Factor
~ Safety_Factor J -
Wall Allowable_Shear: 94.164.pIf
Page 5of 18
END ZONE LOADING TO ROOF DIAPHRAGM:
cgE~all := ,375.EH-pA.Ewall
'- ~RS E~'V).PAErooI
Eroof '- ~
EL := ¢)E wall + tOE roof
INTERIOR ZONE LOADING TO ROOF DIAPHRAGM:
tOE walI = 137.618.plf
OJE.roof = 0.plf
EL = 137.618.plf
W[.wa!l = 91.71 I'plf
CO ' - 0'plf
Iroot --
IL = 91.711 'plf
14(
EZW
13(
12(
11(
10(
9£
WIND LOADING DIAGRAM
20 40 60
Building Length
3851.7
2393.5
935.3
- 522.8
- 1981'
- 3439.2
SHEAR DIAGRAM
Building Length
SHEAR TO ENDWALL
SHEAR TO END_~3851.681 lbf
~ ~= Page 6otl 8
ROOF:
RW := BW + 2.SOW RW = 50ft
Allowable Diaphragm_Shear_Roof :: Roof Allowable Shear. RW
Allowable_Diaphragm Shear_Roof = 4708.21bf
END WALL #1:
SHEAR TO END 1: 3852.1bf
Available_Siding := 27.fl
Allowable End Wall_l := Available Siding. Wall_Allowable_Shear
Allowable End Wall I= 2542.4.1bf
7/16" OSB Shear wall Allowable_Shear:= 1.4.0.92.200.plf
End_Wall_l_Reinforcing Length :=
(SHEAR_TO END 1-Allowable_End_Wall_l)
Allowable Shear
End Wa _ _Re nforcing Length = 5.083fi
END WALL #2:
SHEAR_TO END 1= 3852.1bf
Available_Siding := 48.ft
Allowable End Wall 2 := Available_Siding. Wall_Allowable_Shear
Allowable End Wall 2: 4519.9.1bf
Page 7of 18
SIDE WALL COLUMN DESIGN CRITERIA - END ZONE:
Column analysis with Roof Diaphragm; therefore, columns are
considered as propped cantilevers,
Check # 1 - 3/4 wind, 3/4 LL, Full DL ~,, base
Axial Reduced Live:= [(0.75.LL)+DL + CL].BS.[~2"
Axial Reduced Live = 3112.5.1bf
Axial Wind Reduced := P^2Ei-.7>BS. + SOW
2
Axial_Wiud Reduced = 2~!55791bf
+ SOW1
\xial_Reduced Live + Axial , , ~.~educed
PN = 996.921 .lbf
w reduced := PAIEI'BS'.75
w reduced: 91.296.plf
Ma := ( w_redu~ed. EH2_
Ma = 2751.176.ftlb I f ff~
Mb := [I3'w reduced. EH-(EH- X)I - w redt~ecb(E.- X)2
118 - J 2 l.S.
C°lumn S~e=;4.;~.2i~: Laminated. C__;t~l.;;'.'in2 Id = 30'55 ~ X = 1.5.ft[
S: 22.69. in3 Ss = 15.12. in3
Fc = 1750.psi Fcs = 1750.psi
Fb - 1900.psi Fbs- 1650.psi
Ft = 900.psi Fi, = 900.psi
At = 24.75.in2 At.s = 16.5.in2
j
INTERACTION_VALUE = 0.526
Check # 2 - 3/4 wind, 3/4 LL, Full DL ~, splice
INTERACTION
VALUE := + --
- As. Flc. i.6
Ss'Fbs-l.6' I- F~E
INTERACTION VALUE = 0.504
Check # 3- Full LL, Full DL
Total ,\xial := (LL+ DL + CL).Bs.(B)V
_!a} Axial = 3900.1bf
INTERACTION_VALUE := (Total_Axial
A¢lc.l.15)
INTERACTION_VALUE = 0.385
+ SOW)
Check # 4 - Full Wind, Full DL (~, base
Axial Deado6 := 0.6.(DL + CL).Bs.(B2W + SOW)
Axial Deado6 = 450.1b
Axial Wind := PA 2E.I .BS.( BW2 + SOW
Axial Wind =-2820.772.1bf
PNt := Axial Deado6 + Axial_Wind
PNt = -2370.772.1b
w:= pA iE i.BS
w- 121.728.plf
Ma = 3668.235.Rib
Mb = -2033.278. ftlb
w.(EH2- X)21
INTERACTION VALUEt := tAcFt'I'6) + L' 3
INTERACTION_VALUEt = 0.705
Check # 5 - Full wind, Full DL ¢~, ,sp ce
1NTERACTION~ALUEts:= At~l.~) L' 'J
INTERACTION'VALUEr s =
0.~
Page ~__f 18
SIDE WALL EMBEDMENT - END ZONE:
Design Criteria: Restrained at ground with Base Anchor Straps in concrete floor
To find required embedment depth, solve simultaneous equations below
Initial try:
d:- 4.fi
hP: M
Given
'~ 4.25.hP
S3 := 1600.psf
B = 0.592fl
S3= 150.2.1.33.d.(~)
/)
:= Find(d,S3)
S~
COLUMN EMBEDMENT DEPTH: d=4.041
S3 = 1612.464.psf Soil Classification #4
BASE ANCHOR STRAP CHECK: ~30°
Horizontal Shear at Grade: 3/16"X3/4"X30" ~'~
SHEAR -- 981.858.1bf H.R. Flat Steep
Allowable Shear resisted by two Base Anchor Straps:
Consider 22,000 psi steel ~ 0' 177" ;s2ffteS"~t;;~le el
Steel Area = 0.105 in2 \X Anchor Nails
Therefore Allowable Shear = 4620 lb ~- 3 Member Column
Allowable Shear resisted by 8 - Stainless Steel Nails:
= 8(216)(1.6) = 2764 lb
Allowable Withdrawal of Strap in Concrete:
: (1.0 in)(0.75 in)(2)(2000 psi): 3000 lb
SIDE WALL FOOTING:
Allowable Soil Bearin~ Pressure:= 2000.psf
Footing_Diameter := 18.in
Footin~ Thickness = 8.in
Footing_Diameter .~
mreaact :=
4
P
Arearcqd.
Allowable_Soil_Bearing Pressure
SIDE WALL FOOTING UPLIFT - INT ZONE:
UPLIFT:=P^2.2'(~-(BW + SOW).BS
UPLIFT = 2757.384.1b
P
= 3.083. ft
: 0.75.ft
~ = 18.inJ~
d = 4.041 fl
Areaact = 1.767fl2
Areareqd = 1.594ft2
d L041 fl.
RI = 9.in
R2: d.tan(.5236) + Ri
R3 := R2 - RI
Soil Volume Above Footinq
V:= 1.~.d.(Ri2+R22+Rt.R2)
3
V - 52.397 ft3
Total Soil Weight
Allowable Soil Weight:= 100.pcf
TSW := V-Allowable_Soil Weight
TSW = 5239.741.1b
Buildinq Dead Load
BDL:= (DL+ CL).BS.I(~)
BDL = 750.1b
Total Weiqht on Footinq
TWF := TSW + BDL
TWF = 5989.741.1b
COLUMN TO FOOTING CONNECTION:
NET_UPLIFT := UPLIFT - (0.6.BDL)
NET UPLIFT = 2307.384.1b
No. of Nails Required to Resist Uplift =
NAILS = 12
+ sow
Page 11of 18
TRUSS TO COLUMN CONNECTION:
ROOF LOAD
Truss is saddled between outside members of column and bearing on center member with
(2) 1/2" Diameter through Machine Bolts and (8) 20d R.S. Nails
Connector_Load = 3114.2.1bf
P:- Total Axial
Center_Memberls "2x6" Areacentermcmbcr = 8.25.sqin
UPL ,'F ,~
Bearing Shcss :=
(P Connector : oad)
Connector_Load = 4332.8.1b
BDL = 750.1b
NETUPLIFT := UPLIFT - 0.6.BDL
NET_UPLIFT 3511.759.1b
Bearing_Stress = 95.248.psi
UPLIFT = 3961.759.1b
Page i2of 18
PURLINS:
Purlin Size - "2 x 4 (No. 2 SPF)"
Fb = 875.psi
S 3.063. in3
I = 5.359. in4
E 1400000-psi
Spacing := 23.in
CreepFactor := 1.5
Roof sheeting load .......
Purlin dead load ..........
SL := 0.9. psf
PL = 1.l.psf
Total .Loadstrcngth := (LL.cos(O) + SL + PL)
Total Loads~ren? -- 17,938.psf
Total Loadslre~ th. Spacing. BS-
Sreq :=
Fb'Cr'Cd'CF
Sreq = 1.671.in3
SIDE WALL NAILERS:
Nailer_Size = "2 x 6 (2100 MSR)"
Fb = 2100.psi
S = 2.063. in3
l= 1.547. in4
E = 1800000.psi
Spacing := 36.in
Total Load := PCC42
Total Load :-21.636.psf
Sreq = 1.417-in3
SP = 7.125
Fb'(;r'Cd' C1 Ctb
Page 13ofA 8_~;
~5-
SEISMIC DESIGN:
Seismic Use Group := "I"
Site_Class := "D"
Spectral response acceleration @ short periods (Ss):
Spectral response acceleration @ 1-second periods (S1):
Site coefficient (fa):
Site coefficient (fv):
S~:qs := Fa'Ss Sills = 0.392
Ss := .245
S1 := .074
Fa = 1.6
Fv 2.4
Stol := F, St Sn., = 0.178
2 S : 0.261
SDS:= (~)' ,-ns SDS
2 S
SD, := ('~)' illl SDi = 0.118
Seismic_Design_Category_Ss = "B"
Seismic Design_Category_SI = "B"
Note: Most severe category governs; therefore
Seismic_Design Category = "B"
DESIGN REQUIREMENTS FOR SEISMIC CATEGORY B
WL := 12-psf
W - 65842.816.1b
Is building light-framed construction three stories or less in height?
Response modification factor (R): R := 7
Occupancy importance factor (IE): lE := 1.0
Building Weight: W = 65842.816.lb
SIMPLIFIED ANALYSIS PROCEDURE (SAP) FOR SEISMIC DESIGN OF BUILDINGS
SAP = "APPLICABLE"
LFC3less .= YES
1.2. SDS
V~ := --.WI = 1941.993.1b
R
HEADER (Section C-S6):
Span := 22.5.fl Left. Span := 0.Pt
Utotal := (13psf + 4psf).BS-( 4;ft
BS := 7.5.ft
+ lt~} = 3187.5.1bf
pli,e := (17psf).BS/'48~
+lft =3187.5.1bf
2
P P P P
R
t BS = 7.5 tt t
Span = 22.5 ft
Header = "5 I/4 x 16 1/2 Glu-lam"
Fb = 2400.psi S = 238.22.in3
Ct= I E = 1800000.psi
Cd = 1.15 I = 1965.3.in4
Sel(Weight = 25.2.plf
Door_Weight: 39-plf
Camber: 0.38.in
Allox~a ~le [',~ ~ l:b. Cr. Cd-S
Allowable_Moment = 54790.6.fi.lbf
Mrnax: 27968.906-~.1bf
mmax
Sreq :: 121.604 in3
C,.Cd-Fb
Page 15of 18
Deflection_LimittotaI := 240
Allowable DeflectiontotaI :=
Span
Deflection_LimittotaI
Allowable DeflectiontotaI = 1.125. in
Deflection Pointlive = 0.629. in Deflection_Pointdcad = 0.in
Deflection Uniform = 0.I 57. in
Total_Deflection := Deflection Pointli~e + Deflection_Pointdead + Deflection_Uniform - Camber
Total Deflection = 0.406.
Deflection ChecktotaI = "~ ]cadet nleets total deflection requiremct~,''
Deflection_Limitlive := 360
Allowable_Dellcctiunli~ c .=
Span
Deflection Limitlive
Allowable Deflectionli~e = 0.75.in
Live Deflection := Deflection_Pointlive
Deflection_Pointliv¢: 0.629.in
Deflection_Checklivc = "Header meets live load deflection requiremets"
JAMB COLUMN CHECK:
Column analysis with Roof Diaphragm; therefore, columns are
considered as propped cantilevers.
Columns in Interior Zone Full Wind, Full Dead, Full Live
R = 7097.25.15
Axial Wind := Uplift. Lineal feetleW(BW2 + SOW)
Axial Wind = 6895.313.1b
PN := R Axial Wind
PN = 201.937.15
w:= Wind. Lineal £eetlea
w = 220,688-p1£
6627.52 I. ftlb
Mb = -3668.93.filb
Column_Size = "3 - 2x8 Laminated Column" Id = 23.17
A = 32.62. in2 At = 32.62. in2 Fb = 1730.psi
S = 39.42. in3 Ss = 26.28. in3 F~ = 825-psi
I-c = 1650.psi Fo,-- 1650-psi ;.~: 32.625.in~
Fb.s = 1500.psi
Ft ~ = 825.psi
'"-ts = 21.75'ind
INTERACTION_VALUE := (- PN )2
INTERACTION_VALUE -- 0.734
PN / 2
INTERACTION_VALUE := (As.~c. 1.6 ~
INTERACTION_VALUE -- 0.703
Page 17of18
LEFT JAMB EMBEDMENT:
Design Criteria: Restrained at ground with Base Anchor Straps in concrete floor
To find required embedment depth, solve simultaneous equations below
Initial try:
d :: 4.fi S;:= 1600. psf
hP:= Ma B =0.711fl
9 4.25.hP
S3.B
S3= 150-2' 1.33'd'(c~)
d) Find(d S3)
S3
COLUMN EMBEDMENT DEPTH: d = 4.631ft
S3 = 1847.589. psf Soil Classification #4
d - 8in = 3.964fl.
Page 18o[18
B~l~DIN~USE~maciime: slied
BUILDING DESCRIPTION:
WIDTH .....................................
LENGTH ...................................
SIDE OVERHANG WIDTH .........
END OVERHANG WIDTH ..........
GRADE TO HEEL HEIGHT ........
ROOF SLOPE ..........................
BAY SPACING .........................
END BAY SPACING ..................
BUILDING VOLUME .................. BV = 984]5
PEAK HEIGHT ..........................
DESIGN LOADS:
WIND SPEED .............................
EXPOSURE CATEGORY .............
ENCLOSURE CLASSIFICATION...
WIND IMPORTANCE FACTOR .....
GROUND SNOW LOAD .............
SNOW EXPOSURE FACTOR ....
SNOW IMPORTANCE FACTOR..
THERMAL FACTOR ..................
ROOF SURFACE .....................
~?.,.-,~20 mph
EC:!-~!"B,
En~ iC ~ENCLOSED,
S~e :~ ~sLIPPERY"
REFERENCED STANDARDS:
SLOPED ROOF SNOW LOAD
Ps := 0.7'Ce'Is'ps'Ct'Cs
Ps = 12.6-psf
MINIMUM ROOF LIVE LOAD
Lr := 20.psf. RI.R2
Lr = 16,8'psf
DESIGN LIVE LOAD ................... LL = 16.8.psf
DEAD LOAD ...............................
aElUNG LOAD ...........................
ASCE 7-05
IBC 2006
NDS 2001
04-, Zo. O
Page. 1of 18
WIND CALCULATION:
W1
EH= 15.5 fi
BW = 48 fi ~
WIND DESIGN COEFFICIENTS: ,.
WIND DIRECTIONALITY FACTOR .................................................. 1~ := 0.85
3-SECOND GUST SPEED POWER LAW EXPONENT ..................... ~ = 7
NOMINAL HEIGHT OF THE ATMOSPHERIC BOUNDARY LAYER .... Zo =
MEAN ROOF HEIGHT ................................................................... H = 19.527.fi
HEIGHT ABOVE GROUND LEVEL (ASCE minimum) ....................... z = 30fi
VELOCITY PRESSURE EXPOSURE COEFFICIENT ........................ r~z = 0.7
VELOCITY PRESSURE... q := 0.00256.Kz. Kd. V3s2.lw-pSf q = 16.904.psf
EDGE STRIP WIDTH ....... ESW = 4.8 fi:
END ZONE WIDTH .......... EZW = 9.6 fi
INTERNAL PRESSURE COEFFICIENTS:
GCpi.lN = -0.18
GCpi. OUT= 0.18
EXTERNAL PRESSURE COEFFICIENTS - CASE A - TRANSVERSE LOADING:
END ZONES
GCpf. A.iE = 0.78
GCpf. A.2E = -1.07
GCpf. A.3E = -0.673
GCp£A,4E = -0.618
GCp£A 5E = 0.78
GCp£A.6E = -0.618
INTERIOR ZONES
GCp£A.1 = 0.516
GCp£^.2 = -0.69
GCp£A.3 = -0.469
GCp£A.4 = -0.4 ! 5
GCpt~A5 = -0.45
GCp£A.6 = -0.45
Page 2of 18
MWFRS DESIGN PRESSURES - CASE A - TRANSVERSE LOADING:
END ZONES
PA.IE.I := q'(GCpt~A. IE - GCpi. IN) PA. IE.1
PA,2E.I := q'(GCpEA.2E - GCpi.iN) PA.2E.I
PA.3E.I TM q'(GCpi2A.3E- GCpi.lN) PA.3E.I
PA.4E.1 := q'(GCp£A.4E- GCpi. IN) PA.4E.I
PA.5E.I := q'(GCp£A.5E - GCpi.IN) PA.5E.1
PA.6E.I := q'(GCp£A.6E - GCpi. IN) PA.6E.I
= 16.23.psf
= -15.044.psf
= -8.339. psf
= -7.405.psf
= 16.23.psf
= -7.405-psf
PA.IE.2 TM q'(GCpfiA.1E -- GCpi. OUT)
PA,2E.2 := q'(GCp£A.2E -- GCpi.OUl)
PA.3E.2 := q'(GCp£A.3E - GCpi.OUT)
PA.4E.2 := q'(GCp£A.4E - GCpi. OUT)
PA.SE.2 := q'(GCp£A.SE - GCpi.OUT)
PA.6E.2 := q'(GCpf. A.6E -- GCpi.O'dT)
INTERIOR ZONES
PAll := q'(GCpf. A.l - GCpi,IN)
PA.2.1 := q'(GCp£A.2 - GCpi.lN)
PA.3.1 := q'(GCpf. A.3 - GCpi.lN)
PA4.1 := q'(GCpf. A.4- GCpi. IN)
PA.5.1 TM q'(GCp£A.5 - GCpi. IN)
PA.6.1 := q'(GCp£A.6 - GCpi. IN)
PA.I E,2 = 10.145.psf
PA.2E.2 = -21.129.psf
PA.3E.2 = --14.424-psf
PA.4E.2 = -13.491 .psf
PA.SE.2 = 10.145.psf
PA.6E.2 = -13.491 .psf
PA.l.l = 11.772.psf
PA.2.1 = -8.621.psf
PA.3. I = -4.877- psf
PA.4,1 = -3.979. psf
PA.5.1 = -4.564-psf
PA.6A = -4.564. psf
PA.I.2 TM q'(GCpf. A.1 - GCpi.olyr)
PA.2.2 := q'(GCpf. A.2 - GCpi.OUT)
P^.3.2 := q'(GCpi~^.3 - GCpi. OUT)
PA.4.2 := q'(GCp£A.4 - GCpi. OUT)
PA.$2 := q'(GCpf. A.5 - GCpi.OUT)
PA.62 := q'(GCp£A6 - GCpi. OUT)
PA.I.2 = 5.687. psf
PA.2.2 = -14.706.psf
PA.3.2 = -- 10.962. psf
PA.4.2 = -- 10.064.psf
PA.5.2 = --10.649.psf
PA6.2 = --10.649.psf
Page 3of18
EXTERNAL PRESSURE COEFFICIENTS - COMPONENTS AND CLADDING:
GCpl = -0.9
GCp2 = -1.7
GCp3 = -2.6
GCp4 := -1.1
GCp5 := -1.4
COMPONENTS AND CLADDING DESIGN PRESSURES:
PCCI.1 := q'(GCpI - GCpi. IN)
PCC2.1 TM q'(GCp2 - GCpi. IN)
PCC3~I := q'(GCp3 - GCpi.IN)
PCC4.I := q'(GCp4 - GCpi. IN)
PCCS.I := q'(acp5 - GCpi. IN)
PCCI.2 := q'(GCpl - GCpi. OUT)
PCC2.2 TM q'(GCp2 - GCpi.OUT)
PCC3.2 := q'(GCp3 - GCpi. OUT)
PCC4.2 := q'(GCp4 - GCpi. OUT)
PCC5.2 := q'(GCp5 - GCpi.OUt)
PCCL! = -12.171.psf
PCC2.1 = -25.693.psf
PCC3.1 = -40.906.psf
PCC4.1 = -15.551.psf
PCC5A = -20.622.psf
Peel.2 = -18.256.psf
PCC2.2 = -31.779.psf
PCC3.2 = -46.992-psf
PCC4.2 = -21.636-psf
PCC5.2 = -26.708.psf
Page 4of18
MAIN WINDFORCE-RESISTING SYSTEM:
END ZONE HORIZONTAL LOADS
PA.Ewall = 23.636-psf
PA.Eroof = O.psf
INTERIOR ZONE HORIZONTAL LOADS
P^.wa~I = 15.751-psf
PA.roof = 0.psf
DIAPHRAGM PROPERTIES:
ROOF
Safety_Factor := 2.5 Duration_Factor := 1.33
ROOf Ma~ri~i! 01019 Hi'Rib Steel Ultimate_Shear ~ ~77~p f,
f Ultimate Shear'~
Roof Allowable Shear := |. ~ -l.Durafion Factor
- - ~, Safety_Factor J -
Roof_Allowable_Shear = 94.164.plf
WALL
Safety_Factor := 2.5 Duration Factor := ].33
Wall Matefial~ 0.019 Hi-Rib steel Ultimate_Shear := 177.plf
/'Ultimate Shear '~
Wall Allowable Shear:= |---------~----.1.Duration Factor
- - ~, Safety_Factor J -
Wall_Allowable_Shear = 94.164.plf
Page 5of 18
END ZONE LOADING TO ROOF DIAPHRAGM:
~OE.wall := .375.EH.PA.Ewall
(RS
EL := ~0E.wall + ~OE,roof
INTERIOR ZONE LOADING TO ROOF DIAPHRAGM:
~l.wall := -375'EH'pA.waiI
RS ' 'P^,roof
t~l.roof := ~'
(OE.wall = 137.618.plf
(~E. roof= 0.plf
EL = 137.618.plf
Wi.wall = 91.71 l-plf
~01,roof = 0.plf
1L = 91.711.plf
140
130
120
110
100
90
5235,4
3225.~
1215.!
- 794.]
- 2804.1
- 4814.!
[Zw
WIND LOADING DIAGRAM
50 100
Building Length
SHEAR DIAGRAM
Building Length
SHEAR TO ENDWALL
SHEAR_TO END 1 = 5235.411 lbf
Page 6of 18
ROOF:
RW := BW + 2-SOW RW = 50ft
Allowable_Diaphragm_Shear_Roof := Roof_Allowable_Shear. RW
Allowable_Diaphragm_Shear_Roof = 4708.2 lbf
Roof_Reinforcing_l := SHEAR_TO_END_I - Allowable_Diaphragm_Shear_Roof
Roof_Reinforcing_l = 527.211 .lbf
Roof_Reinforcing_l
Reinforcing_Length_l :=
EL
Reinforcing_Length_l = 3.831 ff
END WALL #1:
SHEAR TO END 1 = 5235.1bf
Available-Siding ;= 27 fi
Allowable End Wall I := Available_Siding. Wall_Allowable_Shear
Allowable_End_Wall_l = 2542,4.1bf
7/16" OSB Shear wall ~i~wable_Shear := L~i 0!92:300~Pl f
End_Wall_l_Reinf0rcing_Length :=
(SHEAR_TO END_I - Allowable_End_Wall_l)
Allowable Shear
End_Wall_l_Reinforcing_Length = 6.969ft
END WALL #2:
SHEAR TO END I = 5235-1bf
Allowable End Wall 2 := Available_Siding. Wall_Allowable_Shear
Allowable End Wall 2 = 4519.9.1bf
7/16" OSB shear ~all Allowable Shear;:--E4*0~92400~lf
End_Wall_2_Reinforcing_Length := (SHEAR_TO_END_I -Allowable End Wall_2)
Allowable_Shear
End_Wall_2_Reinforcing_Length = 1.852 ft
Page 7of 18
SIDE WALL COLUMN DESIGN CRITERIA - END ZONE:
Column analysis with Roof Diaphragm; therefore, columns are
considered as propped cantilevers.
Check # 1 - 3/4 wind, 3/4 LL. Full DL ~ base
IBW )
Axial Reduced Live := [(0.75.LL) + DL + CL].BS. + SOW
Axial_Reduced_Live = 3112.5.1bf
Axial_Wind_Reduced:= p^.2E.i-.75-Bs./B2W + SOW)
Axial Wind Reduced =-2115.579-1bf
P
PN := Axial_Reduced_Live + Axial Wind Reduced ] .
PNTM 996.921-lbf
w_reduced := PA. lE.I'BS'.75
w_reduced = 91.296-plf
M '- ('w-redu-?d'EH2~
Ma = 2751'176'ffib
II
Mb~TM . M' I
S = 22.69. in3 Ss = 15.12-in3
Fc = 1750.psi Fc.s = 1750-psi
Fb = 1900-psi Fb.s = t650.psi
Ft = 900.psi Ft ~ = 900-psi
At = 24.75'in2 &.s = 16.5'in2
INTERACTION_VALUE = 0.526
Page 8of 18
Check # 2 - 3/4 wind. 3/4 LL. Full DL (~ solice
INTERACTION_VALUE = 0.504
Check # 3 - Full LL, Full DL
Total_Axial = 3900.1bf
~TE~CTION VAL~ := ~Tota~Axial)
- ( A.FIc. I.15)
~c~os_v~ = o.3ss
Check # 4 - Full Wind, Full DL ~ base
...... ~ ..... 'l? ~.1
Axial_Deado.6 = 450-1b
i~:win~:'~ ~^_~.,.Bs. +
Axial Wind = -2820.772.1bf
Pl~t := Axial~Deado.6 + Axial_Wind
PNt = -2370.772.1b
~ At.Ft. 1 6 : S~Fb; l 6
Check ~ 5 - Full wind, Fu~l DL ~ splice
~C~O~V~ s = 0.711
Page 9of18
SIDE WALL EMBEDMENT - END ZONE:
Design Criteria: Restrained at ground with Base Anchor Straps in concrete floor
To find required embedment depth, solve simultaneous equations below
Initial try:
d :~' 2~ii~
hP := Ma
Given
d2 = 4.25-hP
S3.B
S5 !~ 1600.psf
B = 0.592t~
:= Find(d,
S3
COLUMN EMBEDMENT DEPTH: d = 4.041 ft
S3 = 1612.464.psf Soil Classification #4
BASE ANCHOR STRAP CHECK:
Horizontal Shear at Grade:
SHEAR: 981.858-1bf
30o
3/16"X3/4"X30" ~'~
H.R. Flat Steel \
Allowable Shear resisted by two Base Anchor Straps:
Consider 22,000 psi steel
Steel Area = 0.105 in2
Therefore Allowable Shear = 4620 lb
Allowable Shear resisted by 8 - Stainless Steel Nails:
= 8(216)(1.6) = 2764 lb
Allowable Withdrawal of Strap in Concrete:
= (1.0 in)(0.75 in)(2)(2000 psi) = 3000 lb
0.177" x 2.25"
Stainless Steel
Anchor Nails
3 Member Column
Page lOof 18
SIDE WALL FOOTING:
Ali0wah ~ S0il B,'~h~: P~sUre :~ 2000
P := (13psf + DL + CL).BS.~BW + SOW/ = 3187.5.1b
Foot ng~ :~ !~ifi
Footing, Thickness = 8.in
2
Footing_Diameter .~
Areaact .-
4
P
Areareqd := Allowable Soil Bearing_Pressure
SIDE WALL FOOTING UPLIFT - INT ZONE:
UPL1FT :=-PA.2.2-/B2W + SOW).BS
UPLIFT = 2757.384-1b
P
(~ = 18.in~
d = 4.041 ft
AXeaact = 1.767ft2
Area~eqd = 1.594ft2
d = 4.041 ff
Rl = 9.in
R2 := d.tan(.5236) + R1
R3:= R2-R~
Soil Volume Above Footinq
V:= 1.'n.d.(R,2 + R22+ R,-R2)
3
V = 52.397fl3
Total Soil Weiqht
Allowable Soil Weight := 100*pcf
TSW := V.AIlowable Soil Weight
TSW = 5239.741.1b
Buildinq Dead Load
BDL = 750-1b
Total Weioht on Footinq
TWF := TSW + BDL
TWF = 5989.741.1b
COLUMN TO FOOTING CONNECTION:
NET_UPLIFT := UPLIFT - (0.6.BDL)
NET_UPLIFT = 2307.384.Ib
NO ~fN~i~RequiredtoResistUpliff= NAILS= 12
Page 11of18
TRUSS TO COLUMN CONNECTION:
ROOF LOAD
Truss is saddled between outside members of column and bearing on center member with
(2) 1/2" Diameter through Machine Bolts and (8) 20d R.S. Nails
Connector_Load = 3114.2.1bf
P := Total_Axial
Center_Member_Is = "2x6" Areacentermember = 8,25.sqin
Bearing_Stress :=
UPLIFT
(P - Connector_Load)
Areacentermember
Connector_Load = 4332.8.1b
BDL = 750.1b
NET_UPLIFT := UPLIFT - 0.6-BDL
NET_UPLIFT = 3511.759.1b
Bearing_Stress = 95.248:psi e~ x
(.w w)
UPLIFT := PA.2E,2' + SO .BS
2
UPLIFT = 3961.759.1b
Page 12of 18
PURLINS:
Purlin_Size = "2 x 4 (No. 2 SPF)"
Fb = 875.psi
S = 3.063.in3
I = 5.359.in4
E = 1400000.psi
Creep_Factor := 1.5
Roof sheeting load .......
Purlin dead load ..........
SL i= O~'~f
PL = l.l-psf
Total_Loads~n~th := (LL.cos(0) + SL + PL)
Total_Loadstmn~th = 17.938.psf
[.(Total-LoadsueT' Spacing'BS2).]
Fb, Cr. Cd.CF
Sreq = 1.671.in3
SIDE WALL NAILERS:
Nailer_Size = "2 x 6 (2100 MSR)"
Fb = 2100.psi
S = 2.063.in3
1 = 1.547. in4
E = 1800000.psi
Total_Load := Pcc4.2
Total_Load = -21.636.psf
[ (-Total_Loa~.Spacing-B S2
Sreq := Fb. Cr. Cd. CF. Cfu
Sreq = 1.417.in3
SP = 7.1251~
Page 13of 18
SEISMIC DESIGN:
Site2C:l~-~ ?D,
Spectral response acceleration @ short periods (Ss):
Spectral response acceleration @ 1-second periods (Si):
Site coefficient (fa):
Site coefficient (fy):
Sins := Fa'Ss Sins = 0.392
:~ ~074
1.6
2.4
Stol 2= Fv-S1
Seismic_Design_Category_Ss = "B"
Seismic_Design_Category_S~ = "B"
Note: Most severe category governs; therefore
Seismic_Design_Category = "B"
Stol = 0.178
SDS = 0.261
SDi = 0.118
DESIGN REQUIREMENTS FOR SEISMIC CATEGORY B
WL:= 12.psf
W = 83022.04-1b
Is building light-framed construction three stories or less in height?
Response modification factor (R): R :~ ?
Occupancy impedance factor (IE): I£:~1.0
Building Weight: W = 83022.04.1b
SIMPLIFIED ANALYSIS PROCEDURE (SAP) FOR SEISMIC DESIGN OF BUILDINGS
SAP = "APPLICABLE"
:LI~C31eSs :~iI!YEs!~
1.2.SD$
Vl := -W~ = 2711.622-1b
R
1.2. SDS
Vt := .Wt = 1966.485.1b
R
Page 14of 18
HEADER (Section C-S6):
:-- 22.5~fi Left~SPa~ ? 0.ff BS i-~ ~,fl
Pto~ -~ {!3~i~,B$ ~+lnl ~3~1875,!bf
P
R
P P
Span = 22.5 ff
P
Header = "5 1/4 x 16 1/2 Glu-lam"
Fb = 2400.psi S = 238.22-in3
Cr = I E = 1800000-psi
Cd = 1.15 1 = 1965.3.in4
Self_Weight = 25.2.plf
Door.Weight = 39.plf
Camber = 0.38-in
Allowable_Moment := IFb-Cr. Cd.S
Allowable_Moment = 54790.6.ft.lbf
Mrnax = 27968.906.ff.lbf
Mmax
Sreq := -- = 121.604.in3
Cr. Cd. Fb
Page 15of18
De, fl~fi0h Limitt0~l !~240
Allowable_De flectiOntotta :=
Span
Deflection_LimittotaI
Allowable_DeflectiontotaI = 1.125-in
Deflection_Poinhive = 0.629.in Deflection_Pointdeaa = 0.in Deflection_Uniform = 0.157. in
Total_Deflection := Deflection_Pointlive + Deflection_Point,lead + Deflection_Uniform - Camber
Total_Deflection = 0.406-in
Deflection_ChecktotaI = "Header meets total deflection requiremets"
Defi¢~6n-Limituve := 360
Allowable_Deflectionlive .~
Deflection_Limitliv,
Altowable_Deflectionlive = 0.75-in
Live_Deflection := Deflection_Pointlive
Deflection_Pointlive = 0.629-in
Deflection_Checklive = "Header meets live load deflection requiremets"
Page 16of18
JAMB COLUMN CHECK:
Column analysis with Roof Diaphragm; therefore, columns are
considered as propped cantilevers.
Columns in Interior Zone Full Wind, Full Dead, Full Live
R = 7097.25-1b
Axial_Wind:= Upliff. Lineal_feetlel,c(B2TM +SOW)
Axial_Wind = 6895.313.lb
PN := R - Axial_Wind
PN TM 201.937-1b
w := Wind-Lineal_feetleft
w = 220.688-plf
Ma = 6627.521-fflb
Mb = -3668.93-ffib
Column_Size = "3 - 2x8 Laminated Column"
A = 32.62.in2 ,% = 32.62. in2
S = 39.42. in3 Ss = 26.28.in3
Fc = 1650-psi Fcs = 1650.psi
Id = 23.17
Fb = 1730.psi
Ft = 825.psi
At = 32.625.in2
INTERACTION_VALUE :=
Ls'Fb'"6'L'
INTERACTION VALUE:=(.
[xAs. Flc. l.6 )
Fb.s = 1500-psi
Ft, = 825.psi
At.s = 21.75.in2
INTERACTION_VALUE = 0.734
INTERACTION_VALUE = 0.703
Page 17of18
LEFT JAMB EMBEDMENT:
Design Criteria: Restrained at ground with Base Anchor Straps in concrete floor
To find required embedment depth, solve simultaneous equations below
Initial try:
d :=:4.R S3 := 1600.psf
Given
hP:=Ma B=0.711fi
d2 = 4.25.hP
SyB
S3= 150'2'1.33'd'(c-~)
Id)
:= Find(d, S3)
S3
COLUMN EMBEDMENT DEPTH: d = 4.631fl
S3 = 1847.589.psf Soil Classification ~
d - 8in = 3.964 f~
Page18of18
Dc
SURVEY OF PROPERTY
SITUATE
CUTCHOOUE
TOWN OF SOUTHOLD
SUFFOLK COUNTY, NEW YORK
S.C. TAX No. 1000-83-03-9)~J'
SCALE 1"--100' -~ -~'
OCTOBER 1, 1999
NOVEMBER 17, 1999 RECONFIGURED RESERVE PARCEL
OCTOBER 21, 2009 ADDED PROPOSED BUILDING
TOTAL AREA = 594,144 sq. ff.
15,659
NO TE:
THIS PROPERTY IS LOCATED IN
ZONING USE DISTRICT: A-C (AGRICULTURAL CONSERVATION)
CERTIFIED TO.
COMMONWEALTH LAND
LIEB VINES, LLC
LIEB VINEYARDS, LLC
TOWN OF SOUTNOLB
TITLE INSURANCE COMPANY
N,Y S Lic No 50467
Nathan Taft CorwIn III
Land Surveyor
PHONE (651)727-2090 Fox (651)727 1727
rq
SURVEY OF PROPERTY
SITUATE
CUTCHOGUE
IOWN OF SOUIHOLD
SUFFOLK COUNTY, NEW YORK
S.C. TAX No. 1000-8.5-03-02
SCALE 1"--100'
OCTOBER 1, 1999
NOVEMBER 17, 1999 RECONFIGURED RESERVE PARCEL
OCTOBER 21, 2009 ADDED PROPOSED BUILDING
OCTOBER 30, 2009 FINAL SURVEY ON METAL BUILDING
TOTAL AREA 594,144 sq. ff.
1 2.639 c~c.
NOTE'
THIS PROPERTY lB LOCATED IN
ZONING USE DISTRICT: A-C (AGRICULTURAL CONSERVATION)
CERTIFIED TO.
COMMONWEALTH LAND
LIEB VINES, LLC
LIEB VINEYARDS, LLC
TOWN OF SOUTBOLD
TITLE INSURANCE COMPANY
THE EXISTENCE OF RIGHTS OF WAY
AND/OR EASEMENTS OF RECOED, iF
ANY, NOT SHOWN AR[ NOT GUARANTEED,
Nathan Taft Corw,n III
Land Surveyor
PHONE (631)727-2090 Fox (631)727 1727
99-589,
4'
~ 20 / O MIE ACCEPTED, (SEE CONDITIONS ON IIESOLUIION)
NOTE: The approved site development plan shall be v~lid for
a period of fl~r~e (3) years f~om the date of approval as per
code section 100-255.
SURVEY OF PROPERTY
SITUATE
CUTCHOGUE
TOWN OF SOUTHOLD
SUFFOLK COUNTY, NEW YORK
S.C. TAX No. 1000-85-05-02,2
SCALE 1"--100'
OCTOBER 1, 1999
NOVEMBER 17, 1999 RECONFIGURED RESERVE PARCEL
OCTOBER 21, 2009 ADDED PROPOSED BUILDING
OCTOBER 50, 2009 FINAL SURVEY ON METAL BUILDING
TOTAL AREA = 594,144 sq. ff.
13.659 Dc.
NOTE:
THIS PROPERTY IS LOCATED IN
ZONING USE DISTRICT: A-C (AGRICULTURAL CONSERVATION)
CERTIFIED TO.
COMMONWEALTH LAND TITLE
NEB VINES, LLC
LIEB VINEYARDS, LLC
TOWN OF SOUTHOED
INSURANCE COMPANY
TOWN ~THOLD
DATE /_ .
Nathan Taft Corwmn III
Land Surveyor
PHONE (631)727-2090
OFFICES LOCATED AT
Fox (531)727-1727
%
%
7
SURVEY OF PROPERTY
SITUA ~£
CUTCHOGUE
TOWN OF SOUTHOLD
SUFFOLK COUNTY, NEW YORK
S.C. TAX No. 1000-83-03-02.2,
SCALE 1"--100'
OCTOBER 1, 1999
NOVEMBER 17, 1999 RECONFIGURED RESERVE PARCEL
OCTOBER 21, 2009 ADDED PROPOSED BUILDING
OCTOBER 30, 2009 FINAL SURVEY ON METAL BUILDING
TOTAL AREA 594,144 sq. ff.
13,639 ac.
NOTE'
THIS PROPERTY IS LOCATED IN
ZONING USE DISTRICT: A-C (AGRICULTURAL CONSERVATION)
CERTIFIED TO.
COMMONWEALTH LAND
LIEB VINES, LLC
LIEB VINEYARDS, LLC
TOWN OF SOUTHOLB
TITLE INSURANCE COMPANY
BY
STANDARDS FOR TITLE SURVEYS AS ESTABLISHED
NOTE: Tbe approved site devclopm~m pl~ sba~l be 'adid ~'
a period of~ee (3) yc~s ~om ~ ~m of ap~v~ m ~ / ' ToLEN ~INGTHE ASSIGNEESINSTITUTIONQFLISTEDTHE LENDINGHEREON' INsTAND-
CO~e 8~ctioR 100-255. /// TUTION CERTIFICATIONS ARE NOT TRANSFERABLE
No, 50467
Nathan Taft Corw~n III
Land Surveyor
PHONE (631)727-2090 Fax (631)727 1727
OFFICES LOCATED AT MAILING ADDRESS
DESIGN AND EXPLANATORY NOTES
MORTON BUILDINGS GENERAL SPECIFICATIONS
LAMINATED COLUMNS - NO, 1 OR BETFER SOUTHERN YELLOW PINE NAIL LAMINATED 3 MEMBER S4S
COLUMNS USED IN MORTON BUILDINGS ARE PRESSURE TREATED BELOW GRADE TO A RETENTION OF .B
POUNDS PER CUBIC FOOT WITH CHROMATED COPPER ARSENATE TYPE III, OXIDE IN CONFORMANCE
WITH USEPA GUIDELINES AND AWPA STANDARD C28. THE TREATED PORTION OF THE COLUMN
EMBEDDED IN GROUND SHALL BE LAMINATED WITH STAINLESS STEEL NAILS.
FOOTINGS AND ANCHORAGE - COLUMN HOLES ARE DUG A MINIMUM DEPTH OF 4'-8" BELOW GRADE
(SEE PLANS FOR DIAMETER AND DEPTH). COLUMNS WITH GALVANIZED SUPPORT STILTS ARE PLACED IN
THE HOLE. CONCRETE (MINIMUM COMPRESSIVE STRENGTH 2500 PSI) IS POURED IN PLACE TO THE
SPECIFIED THICKNESS (SEE PLANS FOR REQUIRED THICKNESS ABOVE AND BELOW THE COLUMN). THE
COLUMN IS THEN BACKFILLED WITH SOIL AND COMPACTED AT B" INTERVALS OR BACKFILLED WITH
CONCRETE (SEE PLANS).
TREATED LUMBER - PRESSURE PRESERVATIVE TREATED LUMBER OTHER THAN LAMINATED COLUMNS ARE
NO. 1 OR BETTER SOUTHERN YELLOW PINE AND CENTER MATCHED OR NOTCHED AND GROOVED,
PRESSURE TREATED TO A NET RETENTION OF .4 POUNDS PER CUBIC FOOT WiTH A CODE AND INDUSTRY
APPROVED PRESERVATIVE TREATMENT IN ACCORDANCE WITH AWPA USE CATEGORY UC4A.
FRAMING LUMBER - SIDING NAILERS ARE 2x4 S4S OR 2x6 SPF NO, 2 OR BETFER SPACED APPROXIMATELY
36" O.C. WITH ALL JOINTS STAGGERED AT ATTACHMENT TO COLUMNS. ROOF PURLINS ARE 2x4 S4S NO.
2 OR BETTER ON EDGE SPACED APPROXIMATELY 24" O.C. ALL OTHER FRAMING LUMBER IS NO. 2 OR
BETTER.
ROOF TRUSSES - FACTORY ASSEMBLED WITH 18 OR 20 GAUGE GALVANIZED STEEL TRUSS PLATES AS
REQUIRED AND KILN DRIED LUMBER AS SPECIFIED, IN PLANT QUALrTY CONTROL INSPECTION rs
CONDUCTED UNDER THE AUSPICES OF THE TPI INSPECTION BUREAU. TRUSSES ARE DESIGNED IN
ACCORDANCE WITH CURRENT STANDARDS AND SPECIFICATIONS FOR THE STATED LOADING.
SIDINg PANELS (KYNAR 500 / HYLAR 5000) - 0.019" MIN., Gg0 GALVANIZED OR AZSB GALVALUME, WITH
AN ADDITIONAL BAKED-ON KYNAR 500 / HYLAR 5000 FINISH WITH A NOMINAL 1 MIL. PAINT THICKNESS
ON EXTERIOR.
ROOFING PANELS (FLUOROFLEX 2000 *~) - 0.019" MIN. AZ55 GALVALUME WITH AN ADDITIONAL
BAKED-ON THICKNESS POLYURETHANE PRIMER AND KYNAR B00 / HYLAR 5000 TOPCOAT WITH A TOTAL
MINIMUM PAINT THICKNESS OF 2 MILS ON EXTERIOR.
TRIM - DIE-FORMED TRIM OF 0.017" MIN., Gg0 GALVANIZED OR AZ55 GALVALUME STEEL ON GABLES,
RIDGES, CORNERS, BASE WINDOWS, AND DOORS WITH SAME FINISH AS ROOFING OR SIDING PANELS~
GU'FfERS - 5" K-STYLE, .030 HIGH TENSILE ALUMINUM GUTFER, KYNAR 500 / HYLAR 5000 FINISH TO MATCH
TRIM, ON BOTH SIDES OF THE BUILDING.
2x4FK 10/09
SHEET INDEX
SHEET# DESCRIPTION
G1 OF G1 SPECIFICATIONS & SHEET INDEX
S1 OF S11 COLUMN PLAN
S2 OF S 11 TRUSS PLAN, TRUSS DRAWING, & DETAILS
S3 OF S l I ELEVATIONS
S4 OF S 11 SECTIONS & DETAILS
S5 OF S 11 SECTIONS & DETAILS
S6 OF S 11 SECTIONS & DETAILS
S7 OF S I 1 SECTIONS & DETAILS
S8 OF SI 1 SECTIONS & DETAILS
S9 OF S11 DETAILS
Sl0 OF S11 DETAILS
S11 OF Sl 1 FASTENING SCHEDULE
TYPICAL LUMBER SPECIFICATIONS - 2005 NDE
SIZE DESCRIPTION BENDING VALUE Fb
2x4 NO.] &2$PF 1313PSI
2x4 2100f MSR SPF 2100 PSI
2x6 NO. 1 &2SPF 113BPSt
2x6 NO. I SYP 1650 PSi
2xB NO. I SYP 1.500 PSi
2x10 NO. I SYP 1300 PSi
2x12 NO. 1 SYP 1250 PSi
ALL 1950t MSR SYP } 950 PSi
1 1/2"xl 6" LAMINATED VENEER LUMBER 2800 PSI
1.) ALL PLOT PLANS AND RELATED DETAILS SHALL BE PROVIDED BY OWNER UNLESS
INCORPORATED AS PART OF THESE DRAWINGS.
2.)MORTON BUILDINGS GENERAL SPECIFICATIONS APPLY UNLESS INDICATED
DIFFERENTLY ON SPECIFIC JOB DRAWINGS OR SUPPLEMENTAL INFORMATION.
3.) MINIMUM LIVE ROOF LOAD DESIGNS FOR CONSTRUCTION, MAINTENANCE,
REPAIR, AND OTHER TEMPORARY LOADS PER SECTION ]607.11.2
a.) ROOF PURLINS AND OTHER SECONDARY STRUCTURAL MEMBERS: 20 PSF
b.) ROOF TRUSSES, HEADERS, COLUMNS AND OTHER PRIMARY
STRUCTURAL MEMBER = 17 PSF
C.) FOOTINGS = 13 PSF )DESIGNED FOR ROOF SNOW LOAD AND OTHER
NON-TEMPORARY LOADS W/APPROVAL FROM BUILDING OFFICIAL.
4.)NO ONE MAY ALTER ANY ENGINEERING ITEM UNLESS ACTING UNDER THE
DIRECTION OF THE LICENSED ENGINEER .
BUILDING DESIGN CRITERIA
BUILDING CODE 2007 NYBC
USE GROUP U-AGRICULTURAL
CONSTRUCTION TYPE
FLOOR AREA (~' 3600 SQ '~T /
BUILDING CATEGORY I
MINIMUM LIVE ROOF LOAD DESIGN SEE NOTE #3
ROOF SNOW LOAD* 13 PSF
GROUND SNOW LOAD 20 PSF
WIND SPEED (Vss) 1120 MPH
WIND IMPORTANCE FACTOR 0.77
EXPOSURE CATEGORY B
INTERNAL PRESSU RE COEFFICIENT -+0,18
BUILDING DESIGN CONDITION ENCLOSED
PEAK HEIGHT 23.5 FT
BUILDING VOLUME 70296 CU FT
WIND LOAD DESIGN ASCE 7 METHOD 2
ZONE I E 16.23 PSF
0.2 S
ZONE 2E -21.13 PSF ACC
ZONE 3E -14.42 PSF
ZONE 4E -T 3,49 PSF ACC
ZONE 5E 13,35 PSF
MAIN WlNDFORCE RESISTINg SYSTEM SEISA
iALL FORCES ACT NORMAL TO THE SURFACE) ZONE 6E -10.31 PSF BUll[
FOR ZONES SEE MWFRS ON ELEVATIONS PAGE} ZONE 1 11.77 PSF
MAXIMUM VALUE SHOWN} SITE
ZONE 2 -14.71 PSF BASI(
ZONB 3 -10.96 PSF SEIS~,
ZONE 4 -10.06 PSF RESP
ZONE 5 9.80 PSF ANA
ZONE 6 -7.9B PSF SEJS~
ZONE 1 11.49, -18.26 PSF J EELS8
COMPONENT & CLADDING WIND LOADS ZONE 2 11.49, -3} .78 PSF (LON
(ALL FORCES ACT NORMAL TO THE SURFACE) ZONE 3 11,49, -46.99 PSF WIN E
(FOR ZONES SEE ELEVAT!ONS) ZONE 4 ]9.95, -21.64 PSF WINI
ZONE 5 19.95, -26.71 PSF MAX
USL' '
VV!THOUT )i!RTIF tA' '!
OF 0CC,,,,,,
* ROOF SNOW LOAD CALCULATIONS
Ps = 0.7xCexlxPgxCtxCs
Ce = SNOW EXPOSURE FACTOR = 1,0
I = IMPORTANCE FACTOR = 0.8
Pg = GROUND SNOW LOAD = 20 PSF
Ct = THERMAL FACTOR = }.2
CS = ROOF SLOPE FACTOR = 0.94
Ps = 0.7xl.0x0.SxS0x1.2x0.94=12.6PSF
EARTHQUAKE DESIGN DATA TABLE
0.2 SEC SPECTRAL RESPONSE
ACCELERATION (Ss] 0.24g
1.0 SEC SPECTRAL RESPONSE
ACCELERATION (S~) 0.07g
SEISMIC DESIGN CATEGORY
BUILDING CATEGORY (TABLE 1604.5) I
SITE CLASS D
BASIC STRUCTURAL SYSTEM AND B23 LIGHT FRAMED WALLS WITH
SEISMIC-RESISTING SYSTEM SHEAR PANELS
RESPONSE MODIFICATION FACTOR (Ri 7
ANALYSIS PROCEDURE SIMPLIFIED ANALYTICAL PROCEDURE
SEISMIC DESIGN BASE SHEAR (TRANSVERSE) 1950 LBS
SEISMIC DESIGN BASE SHEAR
LONGITUDINAL) 1700 LBS
WIND DESIGN BASE SHEAR (TRANSVERSE) 10270 LBS /, ....
WIND DESIGN BASE SHEAR (LONGITUDINAL) 6100 LBS
MAX. DESIGN ELEVATION 1000 FT
gNDERWRITER OERTIFIGAT
· ....., ,,,
RETAIN STORM WATER RUNOFF
PURSUANT TO CHAPTER 238
ALL CO !?TRUCTiO,, ' ",,ALL
q, UrREL', ' ;? THE
I HEREBY CERTIFY THAT THE STRUCTURAL DESIGN FOR
THIS BUILDING WAS PREPARED BY ME O
DIRECT SUPERVISION AND THAT I AM
LICENSED/REGISTERED PROFESSIOI
MICHAEL L.
DATE:
C
AS,
n
II I
III.T:
DA TE: 12/08/09
DA TE: 12/10/09
REVISED DATE.. --
REVISED DA TE: --
REVISED DATE; ---
REVISED DATE: ....
I SCALE: AS NOTED
SHEE~ NO.
G1o G1
b 7'-4 1/2" 7'-6I' ~ 7'-6" 7'-6" c~ 7'-6" e0 7'-6" 7'-6" ,,o 7'-6" m ,a ~ I I--0'I VENTED SIDEWALL OVERHANGS
1'--0" NON'VENTED ENDWALL OVERHANGS
I I I I I I I
-I- I I r --I ]-- I [ --~ 47'9"
47'-9"
o ¢> o
39'-10 1/2" ~ -- ] ~16"R 16"R) -- 39'-10 1/2"
I~'R~ . 34'-1 1/2"
[
31'-101/2" ' --
15'-10 ~/2" ~ ~ ~ 1 ~"~
I 16"R ) ]~I-7 1/2'J
7~'10 1/2'' -- ~ I~"R
1~"~ ~ 7'-10 1/2"
o,-o,, I
I- - I I- I
I ~S6~ I
~ 9 ~ o ~ o ~ _i
COLUMN PLAN
COLUMN PLAN LEGEND
a - 3-2x6 LAMINATED COLUMN LOCATION
B - 3-2x8 LAMINATED COLUMN LOCATION
· - HEADERED TRUSS LOCATION
[] - 3068PLAIN FLATLEAFFIBERSTEELWALKDOOR(S),OUTSWING,
LEFT HINGE WITH LOCKSET & CLOSER
21 '-0" x i 4'-0" DOUBLE SLIDING TWIN PANEL ALUMASTEEL END DOOR(S)
22'-6" x 14'-0" DOUBLE SLIDING TWIN PANEL ALUMAETEEL SIDE DOOR(S}
81M BASE ANCHORS
(B) 3065 SKYLITE(S) (VERIFY LOCATION)
(1) 3'-6" X 3'-6" CUPOLA WITH "M" 30" WEATHERVANE NON-FUNCTIONAL
SIDE AND END STEEL FASTENED WITH STAINLESS STEEL SCREWS
ROOF STEEL FASTENED WITH ZINC PLATED SCREWS
~ - 7/16"OSBSHEARWALL LOCATION (SEE DETAILS SHEETS10 OFSll)
16"R - 16" DIAMETER FOOTING WITH 8" THICK MINIMUM READY-MIX
CONCRETE BELOW BOTTOM OF LOWER COLUMN WITH ADDITIONAL
READY-MIX TO TOP OF 218M STILT (9"_+). PLACE CONCRETE
BELOW AND ABOVE BOTTOM OF LOWER COLUMN IN ONE OPERATION.
18"R - 18' DIAMETER FOOTING WITH 8" THICK MINIMUM READY-MIX
CONCRETE BELOW BOTTOM OF LOWER COLUMN WITH ADDITIONAL
READY-MIX TO TOP OF 218M STILT {9":[;). PLACE CONCRETE
BELOW AND ABOVE BOTTOM OF LOWER COLUMN iN ONE OPERATION,
30"R- 24" DIAMETER FOOTING WITH 13"THICK MINIMUM READY-MIX
CONCRETE BELOW BOTTOM OF LOWER COLUMN WITH ADDITIONAL
READY-MIX TO TOP OF 230M STILT (9"-+). PLACE CONCRETE
BELOW AND ABOVE BOTTOM OF LOWER COLUMN IN ONE OPERATION.
ROUGH OPENING SCHEDULE
UNIT SYMBOL
FROM LEGEND
[]
WIDTH HEIGHT
38 1/4" 81"
2~ 8*
SCALE: ~ I
41
16'
CUTCH GOUGE, NY
JOB NO.
128-0839
CD
7
U
'DRAWH BY: BISHOP
DA TE.' 12/08/09
CHECKED 81 ~M
DA TE: 12/10/09
REVISED DA TE: .--
REVISED DAIE: ----
REVISED DATE ---
,REVISED DA TE: ....
I?.
SCALE; AS NOTED
o,:S1
TRUSS LOCATION DIMENSIONS
ED ~ '¢ ~ ~ ~ T-6" T-6" 7'-6" ~ T-6" ~a 7'-4 1/2"
I
I~> <~
j............. ¥ ............... ¥ .............. ¥ .......... ~ ~ ~ ~ ~ ~
TRUSS/BRACING PLAN LEGEND
- 48' 2090 R.C. TRUSSES @ 7'-6" O.C.
- 48' END RAFTER ASSEMBLY
- 2x4 TRUSS TIES @ 4'-0" O.C.
- 2x6 DIAGONAL END BRACES @ 8'-0" O.C.
(TO EXTEND TO FIRST TRUSS IN FROM ENDWALL)
TRUSS/BRACING PLAN
SCALE: ~r~ I
TOE NAIL OVERHANG RAFTER
TO OVERHANG NAILER WiTH
(1) 16d R.S. NAIL EACH SIDE
OVERHANG FRAME ~ ?/~ -- 1~ ~ 48' 2x10 (NCkl SYP)
2x6 OVERHANG NAILER ~ END RAFTER A~SEMBLY
3-2x6 CORNER COLUMN
DETAIL A
SCALE: 1 1/2"-- 1'-0"
48'-2x10 (NO.1 SYP) ~
~ NAILS
PER CONNECTION
2x6 END COLUMN EXTENSION OR
UPRIGHT ASSEMBLY NAILED TO END
RAFTER ASSEMBLY AS SHOWN AND TO
EACH INTERSECTING WEB. FASTEN TO
HEADER AND FRAMING MEMBER WITH (2}
16d R.S. NAILS INTO EACH END COLUMN
EXTENSION MEMBER OR UPRIGHT,
DETAIL B
SCALE: 11/2" = 1'-0"
9-3-0
~]/~ CENTER 2X4 SYP WEB
STIFFENER ON TRUSS
WEB & NAIL WiTH 3 1/2"
HDGR.S. GUNOR 16d
R.S. NAILS WITHIN 4" OF
END & 6" O.C.,
STAGGERED
2x4 WEB STIFFENER SECTION A
SCALE: 1 1/2"= I'-0"
STIFFENERS
3.953
TRUSS SPACING T-6" O.C.
LIVE LOAD 17 PSF
DEAD LOAD 4 PSF
CEILING LOAD PSF
TOTAL LOAD 21 PSF
4.042
47- 9- 0
48' R.C. 2090 TRUSS
SCALE: 3/8"=
CUTCHOGUE, NY
n
n
O
7
II I
I
II I
DA TE: 12/08/09
CHECKED BY. RM
DA TE: 12/10/09
~EVISED DARE: __
~EVISED DATE: ....
.REVISED DA TE: ....
SCALE; AS NOTED
SHEET NO,
· [ S2o~S11
4.E' WIDE
[ZONE 2 & 3}
(ZONE 3)
{ZONE 2)
(ZONE 3]
37'-6"
4.8' WIDE
J(ZONE 2 & 3)
4.8' WIDE 4.8' WIDE
IZONEEI EAST ELEVATION ~ZONE3~
4.8' WIDE
(ZONES 2 & 3)
'1
4.8' WrDE
(ZONE 2 & 3]
'i
DESIGN AND EXPLANATORY NOTES
I .)EXTERIOR DOOR AND WINDOW LOCATIONS ARE TAKEN FROM THE EXTERIOR FACE
OF THE NAILERS AND ARE TO THE CENTER OF THE DOOR AND WINDOW UNITS.
VERIFY ALL DOOR, WINDOW, SKYLIGHT AND SIDELIGHT LOCATIONS WITH THE
OWNER.
4.8' WIDE
(ZONES 2 & 3]
TRIM
(ZONE2&3) i 4~~ ~
i"(:!i"?!! :i!i((:~i ':E:" :':":::i'::::'";
· I 3E.4' WIDE (ZONE 4, * I'
IZONE 5) NORTH ELEVATION (ZONEEI
(ZONE 2 & 3)
(ZONE 3)
4E 4 6~6E
Reference
Corner
(ZONE 2} --
(ZONE 3} --
,I I.
t 4,8' WIDE
(ZONE 5}
24'-0"
38.4' WJDE (ZONE 4]
4.8' WIDE
[ZONE 5)
b ~
SOUTH ELEVATION
.~TION AL CUPOLA
4,8' WIDE
(ZONE 2 & 3}
4.8' WIDE 4.8' WIDE ,~ l
(ZONE 5) 26'-3" 45'-3" (ZONE 5] '-6",
~, ~ :
- O
~ 'WEST ELEVATION [o
HI-RIB STEEL SIDING
~NER TRIM
WAINSCOT
;TEEL SIDING
CORNER TRIM
tAINSCOT
CUTCHOGUE, NY
7
~D~AWN 8%' BISHOP
DA TE: 12/08/09
CHECKED DY: RM
DA TE: 12/10/09
~EVISED DALE,' ____
~EVISED DATE: -~-
PEVISED DATE; __
~£VISED D_A..~.~: ----
· SCALE: AS NOTED
SHEET NO.
· · S3o~Sl 1 ·
(~) FLUOROFLEX HI-RIB STEEL
~)~) 2x4 PURLINS @
(NO. 2 SPF)
HEADLOX 0.19'x 6" FLATHEAD LAG SCREW
2x4 BEV. PURLIN
WIRE MESH
2x6 BEV. FASCIA
$" O~G, GUTTERS
T# 144 & 146 FASCIA TRIM
HI-RIB/
2,'(60VERH,
~) (2) 1/2"xB I/2" M. BOLTS &
(B) 20d R.S, NAILS
48' 2090 R.C~ TRUSS
~ KYNAR HI-RIB STEEL
GRADE TO HEEL
( 3 ) ROWS 2x6 NAILERS (2100 MSR SPF) ~
LAMINATED COLUMN
2x2 VERTICAL BLOCKING
AT COLUMN LOCATION
T# 167 TRANSITION TRIM
2x6 NOTCHED NAILER ~]
KYNAR HI-RIB STEEL WAINSCOT
7/16" OSB PROTECTIVE LINER ~
T#167 BASE TRIM
( ] ) ROW 2x8 TREATED SPLASHBOARD
18" LOWEST
MEMBER CUT-OFF
~-~ FINISH GRADE
CONCRETE FLOOR 4'
81M BASE ANCHOR ~)
MINIMUM COMPACTED GRANULAR BASE
18"¢
218M (14 GA.) COLUMN STILT ~)
8" THICK MINIMUM READY-MIX CONCRETE
BELOW BOTTOM OF LOWER COLUMN WITH
ADDITIONAL READY-MIX TO TOP OF 2IBM STILT
PLACE CONCRETE BELOW AND ABOVE BOTTOM OF
LOWER COLUMN IN ONE OPERATION·
SIDEWALL SECTION A
SCALE: 1/2" = 1 '-0"
TRUSS IN COLUMN
SADDLE
LAMINATED COLUMN
STILT ISOMETRIC
DESIGN AND EXPLANATORY NOTES
I .) O THE PRECEDING SYMBOL IDENTIFIES ITEMS THROUGHOUT THE PLANS THAT ARE
NOT PROVIDED BY MORTON BUILDINGS, INC, OR MORTON BUILDINGS'
SUBCONTRACTORS AND ARE THE OWNER'S RESPONSIBILITY.
FOOTINGS ARE DESIGNED FOR A 2000 PSF SOIL BEARING CAPACITY. LOCAL
CONDITIONS MAY REQUIRE MODIFICATIONS.
3.) CONCRETE FLOOR NOTES:
a, 3500 PSI, B 1/2 BAG MIX CONCRETE
b. SLOPE GRADE AWAY FROM BUrLDING @ 1" PER FOOT FOR A MINIMUM
DISTANCE OF 10' PLUS OVERHANG WIDTH
c. A VAPOR RETARDER IS NOT MANDATED PER IBC SECTION 1910 EXCEPTION 3.
UNLESS THE FLOOR WiLL BE COVERED BY MOISTURE SENSITIVE FLOORING
MATERIALS OR IMPERMEABLE FLOOR COATINGS OR WHERE THE FLOOR WILL
BE IN CONTACT WITH ANY MOISTURE SENSITIVE EQUIPMENT OR PRODUCT
d, CONTRACTION JOINTS UNIFORMLY SPACED lB' C.C. OR LESS
EXTERIOR
,, , NAIL KEY
~, 0.148 x4' {20d)NAILS
J 10'131" x 3 1/2" HOT DIPPED GALVANIZED (HDG} RING SHANK NAILS
3-2x6 COLUMN SPLICE FASTENING DETAIL
¢CALE: 1/2"= 1'-0"
COLUMN
1/4"xl 1/4"x14 GA. SUPPORT ANGLE
FASTENED TO COLUMN AT EACH
(CORNER WITH (3] ,J48I'(~ x 2"
~TAINLESS NAILS, (12 TOTAL NAILS
F~ER COLUMN)
;HANNEL WITH 1/4" PLATED
FRIVET TO SUPPORT ANGLE
STILT INSTALLATION
1 . INSTALL PRESSURE TREATED
LOWER COLUMN WITH STILT IN THE
AUGERED HOLE.
9~. POUR 9" MINIMUM THICKNESS OF
READEMIX CONCRETE INTO THE
HOLE AS SPECIFIED.
3k BACKFILL AND COMPACT THE
ANNULAR SPACE AROUND THE
COLUMN TO GRADE WITH SOIL
AUGURED FROM THE SITE.
_m3/16"x3/4"x30" H,R. FLAT STEEL
0.177"x2.25" STAINLESS STEEL
ANCHOR NAILS PER STRAP
· BUILDING COLUMN
81M BASE ANCHOR
FASTENING DETAIL
SCALE: 1 1/2"= 1'-0"
CUTCHOGU~E, NY
7
II I
~"DRAWNB~' BISHOP ·
DATE: 12/08/09
CHECKED B) RM
DATE: 12/10/09
REVISED DATE: ---
REVISED DATE; ---
REVISED DATE' ----
REVISED DA TE; --
SCALE: AS NOTED '~
J
SHEET NO.
S4GE S11
GABLE PURLIN FLASHING
T# 16 GABLE TRIM
2x6 FASCIA
T# 194 TRIM
HI-RIB/SOFFIT CAP TRIM
48'- 2x10 (NO.1 SYP)
END RAFTER ASSEMBLY
KYNAR HI-RIB STEEL
2x6 ADDITIONAL NAILER
GRADE TO HEEL
18" LOWEST
MEMBER CUT-OFF
FINISH GRADE
FLOUROFLEX HI-RIB STEEL
2x4 PURLINS @ 23" D.C. ~]~
(NO. 2 SPF)
--~ 2x4 TRUSS TIE
(14 GA.) COLUMN STILT
'FHrCK MINIMUM READI-MIX CONCRETE
BELOW BOTTOM OF LOWER COLUMN WITH
ADDITIONAL READi-MIX TO TOP OF 218M STILT (9'B:) .
PLACE CONCRETE BELOW AND ABOVE BOTTOM OF
LOWER COLUMN IN ONE OPERATION.
:4) 0,I 35" x 2 1/4" R.W. NAILS OR 16d R.S. NAILS
( 1 ) 20d R.S, NAIL THROUGH STRAP
& INTO BRACE
2' END BRACE STRAP W/PRE-PUNCHED
HOLES (BEND TO FIT) FASTENED W/
(3) 0.140 x 1 1/2" R.S. NAILS
2x6 DIAGONAL BRACING FASTENED
TO COLUMN Wi(4) 16d R.S. NAILS
48' 2090 R.C. TRUSS
60d R.S. NAIL
LOWER TRUSS CHORD
(1) #9x1" TRU-GRIP SCREWS ON PEAK SIDE AND
(2) ON EAVE SIDE IN HOLES SHOWN.
(JOJ~T MUST BE TigHT BEFORE FASTENINg CLIPS)
o. GALVANIZED
PURLIN CONNECTOR
2x4 TRUSS TIE DETAIL
ADDITIONAL 2x6 NAILER
2x4 TRUSS TIE TO ENDWALL DETAIL
n
O
7
~DRAWNBY; ~ISHOP ·
DA TE: 12/08/09
CHECKED B~ RM
DA TE: 12/10/09
REVISED DATE:
REVISED DATE: ....
REVISED DATE: ---
ENDWALL SECTION B
SCALE: 1/2"= 1'-0"
ISCALE; AS NOTED
S5o~ S11
14'-0"
GRADE TO BOITOM
OF TRACK GIRT
DESIGN AND EXPLANATORY NOTES
} DOOR HEIGHT HEELHErOHT JAMB COLUMN CUT OFF HT. lB ABOVE HEEL HEIGHT.
/
CUT COLUMN - - Fi~RAIL SEAM HANGER TO COLUMN
51MTRACK ~TiE]~)Ei 1(~0 ~L~U~R2ANXDBE ~i NAILS I
2×3,,AMS ISE¥OND: /
/4"x16 1/2" GLU-LAM HEADER (2400 Fb) fy: BISHOP
-- 2)(8 GIRT (NO. 1 SYP]
NAIL 2x8 GIRT TO BEAM
WITH 20d GUN NAILS
@ 4" O.C. STAGGERED
DA I'E: 12/08/09
CHECKED BY: RM
DA'~E: 12/]0/09
TRUSS
1/2"xl 2" LAGS
(12) 20d R.S. NAILS
~EVISED DATE:
REVISED DA TJ
HANGER
-- FASTEN 340L TRUSS HANGER TO TRUSS WITH
(1) 1/2"x2 1/2" M. BOLT & (14) T 1/2" R.S. NAILS
(PLACE NAILS IN ALL HOLES PROVIDED).
TRUSS HANGER ISOMETRIC DETAIL
(5 1/4"xl 6 7/2" GLU-LAM HEADER WITH 340L TRUSS HANGER)
2x3 JA
OUTSIDE VIEW
*NOTE: VIEWS ARE SHOWN WITH 1'-0" OVERHANGS
5 1/4" GLU-LAM JAMB DETAILS
I' SCALE: AS NOTED
SHEET NO.
· S6 o,': S1
3-2x8 LAMINATED JAMB
COLUMN WITH LAMINATE (BEYOND)
8-2x8 LAMINATED
COLUMN WITH LAMINATE
VERTICAL "1" RAIL
LATCH HANDLE
47E A/S LATCH STRIKE PLATE
HORIZ(
INTERMEDIATE "1" RAILS
JAMB DETAIL
GRADE
CENTER DOOR GUIDE
148 A/S DOOR GUIDE HAS A BUILT-IN STOP
FOR ALUMASTEEL DOORS SO STUB COLUMN
MUST BE EXACTLY CENTERED IN DOOR OPENING
DOOR GUIDE DETAILS
HORIZO
INTERMEDIATE RAIL
RAIL THICKNESS CHART
STANDARD HEAVY
WEB I FLANGE WEB FLANGE WEB FLANGE WEB FLANGE
,070" ,090" .060" .OBO" .090" .150" ,060" ,130"
DOUBLE TOP "D" RAIL
( 16 GUAGE)
/
HORIZONTAL "1" S.S. RArL /
(0.06" WEB, 0.13" FLANGE)
HORIZONTAL "1"
INTERMEDIATE RAIL
[0.06" WEB, 0.13" FLANGE)
~ VERTrCAL "1" RAILS
(0.09" WEB, 0.15" FLANGE)
18E LATCH ~ROD
VERTICAL "1"
(0.09" WEB, 0.18" FLANGE)
LATCH HANDL
DOU8L
{16 GUAGE)
22'-6" x 14' DOUBLE SLIDING DOOR FRAME
{TWIN PANEL)
VERTICAL "1II RAIL --
1264 8" HOOt(
INSTRUCTIONS
T, SCREW NUT ONTO HOOK.
2. SCREW HOOK INTO LATCH BODY.
TRACK gIRT
O
I
]lSHOP
DA TE: 12/08/09
CHECKED 8 RM
DA TE: 12/10/09
REVISED DATE:
REt/ISED DA
13E LATCH ROD --
LATCH ROD
1265 JAMB LATCH
DETAIL LATCH HANDLE
'Z, - tt .- ocl
I $CAL~AS NOTED
SHEET NO,
7oES1 1
RAIL THICKNESS CHART
STANDARD
HEAVY
J VERTICAL HORIZONTAL
VERTICAL I HORIZONTAL J
FLANGE WEB FLANGE WEB FLANGE
KYNAR HI-RIB STEEL
2x6 UPRIGHT
2xl 0 TRACK GIRT
T#71 TRACK COVER
,51M TRACK
Bx4 TRACK BLOCK
1 1/2'x2" BLOCK &T#74
14'0"
TO GRADE
LATCH
2X3 JAMB (BEYOND; ~,
BOTTOM 2' TREATED)
{B)
W/2X6xT' TREATED
SPLICE STIFFENER (BEYOND)
SLIDING DOOR HEADER SECTION D
SCALE; 1": l'-a"
3-2x6 LAMINATED
JAMB COLUMN (BEYOND)
DOUBLE TOP "D" RAIL
UII (16 GUAGE) '~ IIll
HORIZONTAIL "1" S.S. RAIL
VERTICAL
(0.06" WEB, 0.08" FLANGE) (0.09" WEB, 0.1B" FLANGE)
INTERMIEDIATE RAIL
(0.06" WEB, 0.08" FLANGE)
< TRACI
uJ TO G
LU
LU
VERTICAL "1" RAILS
(0.09" WEB, 0.1B" FLANGE)
13E LATCH ROD x,~ LATCH HANDLE ~
GRADE
~ADE
21' x 14' D1OUBLE SLIDING DOOR FRAME
(TWIN PANEL)
OFFI~CHOGUE, NY
I I I
7
DATE: 12/08/09
CHECKED BY: RM
DATE: 12/10/09
SCALE: AS NOTED
SHEET NO,
S8o~Sl
2x4 PURLINS
4.8' WIDE
(ZONE 2 & 3)
48' WIDE BUILDING PURLIN LAYOUT
SCALE: 1/2"= 1'-0'~'
4.8' WIDE
(ZONE 2 & 3}
2x4 PURLIN
HEADLOK .19"x6.0" FLATHEAD LAG SCREW
(ICC-ES REPORT ESRq 078)
(1) #9x1" TRU-GRIP SCREW ON PEAK SIDE AND ·
(2) #9xT" TRU-GRIP SCREWS ON EAVE SIDE OF
PURLIN IN HOLES SHOWN (JOINT MUST BE TIGHT
BEFORE FASTENING CLIPS
2x4 BUTTED PURLIN DETAIL
(PURLIN CONNECTED WITH
6" HEADLOK FLATHEAD LAG SCREW)
SCALE: 1 1/2"= 1'-0"
4.8' WIDE
(ZONE 2 & 3)
O- INDICATES PURLINS TO BE FASTENED
w/HEADLOK ,19" x 6.0" FLATHEAD LAG
SCREW.
4.8' WIDE
(ZONE 2 & 3)
2x4 PURLINS @
- INDICATES PURLINS TO BE FASTENED
w/HEADLOK .19" x 6.0" FLATHEAD LAG
SCREW, ALL OTHER PURLINS TO BE
FASTENED w/60d R.S. NAIL
48' WiDE BUILDING PURLIN LAYOUT
SCALE: 1/2" = 1'-0"
20 GA. GALVANIZED
PURLIN CONNECTOR
60d R.S. NAIL
(1) #9x1" TRU-GRIP SCREW ON PEAK SIDE AND --
[2) #9xl" TRU-GRIP SCREWS ON EAVE SIDE OF
PURLIN IN HOLES SHOWN (~OINT MUST BE TIGHT
BEFORE FASTENING CLIPS
k. GALVANIZED (~)
PURLIN CONNECTOR
2x4 BUTTED PURLIN DETAIL
(PURLIN CONNECTED WITH 60D R.S. NAIL}
SCALE: 1 1/2"= 1'-0"
IJ~iICA~'128-0839
CUTCHOGUE, N~Y _
II I
II I
7
DRA WN 8~' BISHOP
DATE: 12/08/09
CHECKED BY: RM
DATE,' 12/10/09
~EVISED DATE' ....
REVISED DA T~ ....
· SCALE; AS NOTED
SHEET NO.
· S9oFSll
./
CUPOLA ROOF
CUPOLA SIDE (~
FRAME
BASE FRAME
T#167
B CUPOLA SUPPORT ~
BEVELED BASE BLOCK~
;UPOLA BLOCKS
LAMINATED COLUMN
2x6 NAILERS '
LAMINATED COLUMN
OSB SHEARWALL DETAIL
SCALE: 1/2": lU0''
CUPOLA BASE TRIM --
KYN
2x4 PURLINS LOWER CHORD OF
END RAFTER ASSEMBLY
TOP CHORD OF
END RAFTER ASSEMBLY
i[ POLA 2X6 NAILERS :~:-' ='~ ~) = =m= ~'~ ~I~ ~'J ~'= ~ -:' m 2X6 VERTICAL BLOCKS @
1'-0" - -- COLUMN BETWEEN NAILERS
COIL GUN NAILS SPACED 6" O.C,
EXTRA NAILERS ADDEE
BETWEEN STD. NAILERS
(MAX. SPACE TO B~E 24") OSB NAILED TO INTERMEDIATE
................ SUPPORTS W/1-3/4" RINg SHANK
COIL GUN NAILS SPACED 6" C.C.
PEAK PURLIN ~
TRUSS COLUMN
AMING CLIP
2x4 CUPOLA BLOCKS
39Q FRAMING CLIP~
(IF PROTECTIVE LINER IS iNCLUDED)
2x8 TREATED BASEBOARD
CUPOLA FRAMING DETAILS
SCALE: 1"= 1'-0"
7/1 6" OSB SHEARWALL ELEVATION
SCALE: 1/2"= 1~-0''
28-0839 -1
CUTCHOGUE, NY
mil
mil
7
mil
I
mmm~
mmm
~RA WN BY: SHOP
DATE: 12/08/09
CHECKED BY. RM
DATE: 12/10/09
EVISED DATE' ----
REVISED DATE' - _4
REVISED DATE,'
.Il- o(J
ISCALE: AS NOTED
SHEET NO.
Sl0o#Sl
ROOF STRUCTURE FASTENING SCHEDULE
(]) VENT-A-RIDGE TO BASE TRIM #9 x 1" STAINLESS STEEL RUBBER WASHER PANHEAD INTERNAL DRIVE SCREWS @ 8" o,c,
~) RIDGE BASE TRIM TO 2x4 PURLINS #9 x 2" STAINLESS STEEL RUBBER WASHER PANHEAD INTERNAL DRIVE SCREWS AT EVERY HI-RIB (1 '-0" o.¢,)
(~) HI-RIB STEEL TO 2X4 PURLINS #9 x 2" ZINC PLATED RUBBER WASHER PANHEAD INTERINAL DR~VE SCREWS AT EVERY HI-RIB (1 '-0" o.¢.}
® 2O ga. GALVANIZED PURLIN CONNECTORS #9 x 1" TRU-GRIP SCREWS
(]) 2x4 PURLINS TO TRUSS (INTERIOR ZONES) 0.200" x 6'~ (60d) RING SHANK NAILS IN PRE-DRrLLED HOLE
(~) 2x4 PURLINS TO TRUSS (EXTERIOR ZONES) HEADLOK .19"x6.0" FLATHEAD LAG SCREW IN PRE-DRILLED HOLE
(~ 48'STRAIGHTCHORDTRUSSTOCOLUMN (2) 1/2"x5 1/2"M.BOLTS & (8] 0.177"x4"(20d) RING SHANK NAILS
WALL FRAMING FASTENING SCHEDULE
COLUMN STILT (14 GA.) TO COLUMN (12) 0.148" x 2" (6d) STAINLESS STEEL RING SHANK NAILS
81M BASE ANCHOR TO COLUMN 0.177" x 2-1/2" STAINLESS STEEL NAILS (4) PER ANCHOR
2x8 SPLASHBOARD TO COLUMN (4) 0,177" x 4" (20d) STAINLESS STEEL RING SHANK NAILS @ SPLICE/(6) 0.177" x 4" (20d} RING SHANK NAILS @ STANDARD CONNECTION
2x6 NOTCHED NAILER TO COLUMN (4} 0.148" x 3-1/2" (16d) NAILS @ SPLICE/(3) 0.14B"x 3-11/2" (16d) NAILS @ STANDARD CONNECTION
7/I 6" OSB TO SPLASHBOARD & NOTCHED NAILER 0.099" x 1-1/4" ASBESTOS SIDING NAILS
2x6 NAILER TO COLUMN (4) 0.148" x 3-1/2" (16d) RING SHANK NAILS @ SPLICE/ ('6] 0.148" x 3-1/2" (16d} RING SHANK NAILS @ STANDARD CONNECTION
END RAFTER ASSEMBLY TO 2x6 END COLUMN EXTENSIONS (4) 0.177" x 4" (20d) RING SHANK NAILS
2x4 PURLIN TO END RAFTER ASSEMBLY HEADLOK .I 9"x6.0" FLATHEAD LAG SCREW IN PRE-DRiLLLED HOLE
HI-RIB STEEL TO NAILERS #9 x 2" STAINLESS STEEL RUBBER WASHER PANH~.AD INTERNAL DRIVE SCREWS AT EVERY HI-RIB (1 '-0" o,c.l
SOFFIT TO WALL INSERTED IN PRE-FORMED SLOT IN SOFFIT/HI-RIB CAP
SOFFIT TO FASCIA T-50 MONEL STAPLES (2) PER PIECE
7/16" OSB SHEARWALL
OSB TO PERIMETER BLOCKS/FRAMING 0.113" x1-3/4" RING SHANK COIL NAILS @ 6" o.c.
OSB TO INTERMEDIATE FRAMING 0.113" x1-3/4" RING SHANK COIL NAILS @
BLOCKS TO COLUMNS 0.131" x 3 1/2" HOT DIPPED GALVANIZED IHDG) RrNG SlHANK NAILS @ 3" o.c.
SCREWED ROOF STEEL CUPOLA FASTENING
CUPOLA CAP TO CUPOLA ROOF (4) 1/4" x 1" PLATED MACHINE BOLTS AND LOCK WASHIERS
CUPOLA ROOF TO CUPOLA SIDES PRE-FORMED CRIMPED METAL CONNECTIONS AND (B)I #9 x 1" STAINLESS STEEL RUBBER WASHER PANHEAD INTERNAL DRIVE SCREWS
CUPOLA SIDES TO CUPOLA BASE FRAME #9 x I" STAINLESS STEEL RUBBER WASHER PANHEAD INTJ~RNAL DRIVE SCREWS (4) PER SIDE (I 6} TOTAL
CUPOLA BASE FRAME TO OSB CUPOLA SUPPORT 1-7/8" GUN NAILS @ 6" o.c.
OSB CUPOLA SUPPORT TO TREATED BEVELED BLOCK 0.148" x 3-1/2" (16dj RING SHANK NAILS @ E" o.c.
TREATED BEVELED BLOCK TO 2x4 CUPOLA BLOCKS 1/4" x 4-1J2" LAG SCREW W/ 1/4" FLAT WASHER AT EVERY HI-RIB (1 '-0" o.¢.)
2x4 CUPOLA BLOCKS TO FRAMING CLIPS (2) 0.135" x 1-1/2" RING SHANK NAILS
FRAMING CLIPS TO PURLINS (2) 0.135 x 1-1/2 RING SHANK NAILS IN SlD~ OF PURLINI AND (2) 0.1B5 x1-1/2 RING SHANK NAILS IN TOP OF PURLIN
CUTCHOGUE, NY
n
O
(.D
7
PEVISED L
SCALE: AS NOTED
SHEET NO.
Sllo Sll
MORTON BUILDINGS GENERAL SPECIFICATIONS
LAMINATED COLUMNS - NO. 1 OR BETFER SOUTHERN YELLOW PINE NAIL LAMINATED 3 MEMBER S4S
COLUMNS USED IN MORTON BUILDINGS ARE PRESSURE TREATED BELOW GRADE TO A RETENTION OF .8
POUNDS PER CUBIC FETOT WITH CHROMATED COPPER ARSENATE TYPE IlL OXIDE IN CONFORMANCE
WITH USEPA GUIDELINES AND AWPA STANDARD C2R. THE TREATED PORTION OF THE COLUMN
EMBEDDED IN GROUND SHALL BE LAMINATED WITH STAINLESS STEEL NAILS.
FOOTINGS AND ANCHORAGE - COLUMN HOLES ARE DUG A MINIMUM DEPTH OF 4'-8" BELOW GRADE
(SEE PLANS FOR DIAMETER AND DEPTH). COLUMNS WITH GALVANIZED SUPPORT STILTS ARE PLACED IN
THE HOLE. CONCRETE (MINIMUM COMPRESSIVE STRENGTH 2500 PSI) IS POURED IN PLACE TO THE
SPECIFIED THICKNESS (SEE PLANS FOR REQUIRED THICKNESS ABOVE AND BELOW THE COLUMN). THE
COLUMN IS THEN BACi(FILLED WITH SOIL AND COMPACTED AT R'* INTERVALS OR BACKFILLED WITH
CONCRETE (SEE PLANS).
TREATED LUMBER - PRESSURE PRESERVATIVE TREATED LUMBER OTHER THAN LAMINATED COLUMNS ARE
NO. 1 OR BETTER SOUTHERN YELLOW PINE AND CENTER MATCHED OR NOTCHED AND GROOVED,
PRESSURE TREATED TO A NET RETENTION OF .4 POUNDS PER CUBIC FOOT WITH A CODE AND INDUSTRY
APPROVED PRESERVATIVE TREATMENT IN ACCORDANCE WITH AWPA USE CATEGORY UC4A.
FRAMING LUMBER - SIDING NAILERS ARE 2x4 S4S OR 2x6 SPF NO. 2 OR BETTER SPACED APPROXIMATELY
36" C.C. WITH ALL JOINTS STAGGERED AT ATTACHMENT TO COLUMNS. ROOF PURUNS ARE 2x4 S4S NO.
2 OR BETTER ON EDGE SPACED APPROXIMATELY 24" O.C, ALL OTHER FRAMING LUMBER IS NO. 2 OR
BEFFER.
ROOF TRUSSES - FACTORY ASSEMBLED WITH 18 OR 20 GAUGE GALVANIZED STEEL TRUSS PLATES AS
REQUIRED AND KILN DRIED LUMBER AS SPECIFIED, IN-PLANT QUAUTY CONTROL INSPECTION IS
CONDUCTED UNDER THE AUSPICES OF THE TPI INSPECTION BUREAU, TRUSSES ARE DESIGNED IN
ACCORDANCE WITH ~URRENT STANDARDS AND SPECIFICATIONS FOR THE STATED LOADING.
SIDING PANELS KYNAR 500 / HYLAR 5000) - 0.019" MIN., G90 GALVANIZED OR AZ55 GALVALUME, WITH
AN ADDITIONAL BAKED-ON KYNAR 500 / HYLAR 5000 FINISH WITH A NOMINAL 1 MIL. PAINT THICKNESS
ON EXTERIOR.
ROOFING PANELS (FLUOROFLEX 2000 TM) _ 0.019" MIN. AZ55 GALVALUME WITH AN ADDITIONAL
RAKED-ON THICKNESS POLYURETHANE PRIMER AND KYNAR 500 / HYLAR 5000 TOPCOAT WiTH A TOTAL
MINIMUM PAINT THICKi~ESS OF 2 MILS ON EXTERIOR.
TRIM - DIE-FORMED TRIM OF 0.017" MIN., G90 GALVANIZED OR AZ55 GALVALUME STEEL ON GABLES,
RIDGES, CORNERS, BASE WINDOWS, AND DOORS WITH SAME FINISH AS ROOFING OR SIDING PANELS.
GUTFERS - 5" K-STYLE, .030 HIGH TENSILE ALUMINUM GUTTER, KYNAR 500 / HYLAR 5000 FINISH TO MATCH
TRIM, ON BOTH SIDES GE THE BUILDING.
2x4FK 10/09
SHEET INDEX
SHEET# DESCRIPTION
G1 OF G1 SPECIFICATIONS & SHEET INDEX
S) OFSll COLUMN PLAN
S2 OF S11 TRUSS PLAN, TRUSS DRAWING, & DETAILS
S3 OF S11 ELEVATIONS
S4 OF S 11 SECTIONS & DETAILS
S8 OF S11 SECTIONS & DETAILS
S6 OF S11 SECTIONS & DETAILS
S7 OF Sll SECTIONS & DETAILS
S8 OF S 11 SECTIONS & DETAILS
S9 OF S11 DETAILS
SIOOFS]I DETAILS
SI 1 OF SI 1 FASTENING SCHEDULE
TYPICAL LUMBER SPECIFICATIONS - 2005 NDS
SIZE DESCRIPTION BENDING VALUE Fb
2x4 NO, I &2SPF 1313 PSI
2x4 2100f MSR SPF 2100 PSI
2x6 NO, I &2 SPF 1138 PSI
2x6 NO. I SYP 1650 PSI
2.'48 NO. 1 SYP 1500 PS1
2xl0 NO. 1 SYP 1300 PSI
2x12 NO. I SYP 1250 PSi
ALL 1950f MSR SYP 1950 PSI
1 1/2"xl 6" LAMINATED VENEER LUMBER 2800 PSI
3 1/2"xl 5" GLU-LAM 1650 PSI
5 1/4"x16 1/2" GLU-LAM 2400 PSI
DESIGN AND EXPLANATORY NOTES
1.)ALL PLOT PLANS AND RELATED DETAILS SHALL BE PROVIDED BY OWNER UNLESS
INCORPORATED AS PART OF THESE DRAWINGS.
2.) MORTON BUILDINGS GENERAL SPECIFICATIONS APPLY UNLESS INDICATED
DIFFERENTLY ON SPECIFIC JOB DRAWINGS OR SUPPLEMENTAL INFORMATION.
3.} MINIMUM LIVE ROOF LOAD DESIGNS FOR CONSTRUCTION, MAINTENANCE,
REPAIR, AND OTHER TEMPORARY LOADS PER SECTION 1607.] 1.2
a,) ROOF PURLINS AND OTHER SECONDARY STRUCTURAL MEMBERS = 20 PSF
b,) ROOF TRUSSES, HEADERS, COLUMNS AND OTHER PRIMARY
STRUCTURAL MEMBER = 17 PSF
C.) FOOTINGS = 13 PSF (DESIGNED FOR ROOF SNOW LOAD AND OTHER
NON-TEMPORARY LOADS W/APPROVAL FROM BUILDING OFFICIAL.
4.) NO ONE MAY ALTER ANY ENGINEERING ITEM UNLESS ACTING UNDER THE
DIRECTION OF THE LICENSED ENGINEER .
BUILDING DESIGN CRITERIA
BUILDING CODE 2007 NYBC
USE GROUP U-AGRiCULTURAL
CONSTRUCTrON TYPE VB
FLOOR AREA 5040 SQ FT
MEAN ROOF HEIGHT 19.5 FT
BUILDING CATEGORY I
MINIMUM LIVE ROOF LOAD DESIGN SEE NOTE #3
ROOF SNOW LOAD* 13 PSF
GROUND SNOW LOAD 20 PSF
WIND SPEED (V~s) 120 MPH
WIND IMPORTANCE FACTOR 0.77
EXPOSURE CATEGORY B
INTERNAL PRESSURE COEFFICIENT J:0.18
BUILDING DESIGN CONDITION ENCLOSED
PEAK HEIGHT 23.5 FT
BUILDING VOLUME 98415 CU FT
ASCE 7 METHOD 2 J
LOAD
DESIGN
ZONE I E 16.23 PSF
0.2 S
ZONE 2E -21.13 PSF ACC
ZONE 3E -14.42 PSF
ZONE 4E -13.49 PSF j 1.0 SI
ACC
ZONE 5E 13.35 PSF
MAIN WINDFORCE RESISTING SYSTEM SEIS~
(ALL FORCES ACT NORMALTOTHESURFACE] ZONE 6E -10.31 PSF BULL[
(FOR ZONES SEE MWFRS ON ELEVATIONS PAGE) ZONE 1 1 1.77 PSF
EARTHQUAKE DESIGN DATA TABLE
0.2 SEC SPECTRAL RESPONSE
ACCELERATION (Ss) 0.24g
1.0 SEC SPECTRAL RESPONSE
ACCELERATION (St) 0.07g
SEISMIC DESIGN CATEGORY El
BUILD~NG CATEGORY (TABLE 1604,5)
SITE CLASS D
BASIC STRUCTURAL SYSTEM AND B23 LIGHT FRAMED WALLS WiTH
SEISMIC-RESISTING SYSTEM SHEAR PANELS
RESPONSE MODIFICATION FACTOR (Ri 7
ANALYSIS PROCEDURE SIMPLIFIED ANALYTICAL PROCEDURE
SEISMIC DESIGN BASE SHEAR (TRANSVERSE) 2700 LBS
SEISMrC DESIGN BASE SHEAR
LONGITUDINAL) 2000 LBS
WIND DESIGN BASE SHEAR ITRANSVERSE) 14000 LBS
WIND DESIGN BASE SHEAR (LONGITUDINAL) 6100 LBS
MAX. DESIGN ELEVATION 1000 FT
ROOF SNOW LOAD CALCULATIONS
Ps = 0,7xCexlxPgxCtxCs
Ce = SNOW EXPOSURE FACTOR = 1.0
I = IMPORTANCE FACTOR = 0.8
Pg = GROUND SNOW LOAD = 20 PSF
Ct = THERMAL FACTOR = 1.2
Cs = ROOF SLOPE FACTOR = 0.94
PS = 0.7X1.0X0.Rx20xl.2x0.94=1~.6PSF
I HEREBY CERTIFY THAT THE STRUCTURAL DESIGN FOR
THiS BUILDING WAS PREPARED BY ME OR UNDER MY
DIRECT SUPERVISION AND THAT I AM A DULY
LICENSED/REGISTERED PROFESSIONAL ENC_~L~..
/ , /. ,%..
I
O.Am SUng4 · ¢I
CUTCHOGUE, NY
n
O
III
7
III,-
~DRAWNBY; 31SHOP ·
DA TE: 12/08/09
CHECKED BY: ~M
DATE; 12/10/09
~EVISED DATE' JB 04/20/10
REVISED DAr~. .___
P, EVISED DATE' .---
~PEVISED DATE: ---
·
SCALE:AS NOTED
SHEET NO,
glo Gl
IL0'' NON-VENTED ENDWALL OVERHANGS
47'-9" 47'-9"
COLUMN PLAN
COLUMN PLAN LEGEND
o - 3-2x6 LAMINATED COLUMN LOCATION
~ - 3-2x8 LAMINATED COLUMN LOCATION
· - HEADERED TRUSS LOCATION
[] - 3068 PLAIN FLAT LEAF FIBERSTEEL WALKDOOR(S), OUT SWING,
LEFT HINGE WITH LOCKSET & CLOSER
21'-0" x 14'-0" DOUBLE SLIDING TWIN PANEL ALUMASTEEL END DOOR(S)
22'-6" x 14'-0" DOUBLE SLIDING TWIN PANEL ALUMASTEEL SIDE DOOR
81M BASE ANCHORS
(12) 3065 SKYLITE[S} (VERIFY LOCATION)
(1) 3'-6" X 3'~6" CUPOLA WITH "M" 30" WEATHERVANE NON-FUNCTIONAL
ALL STEEL FASTENED WITH STAINLESS STEEL SCREWS
'~ - (2) 7/16"OSB SHEARWALL LOCATIONS (SEE DETAILS SHEET S10 OF Sl l)
16"R- 16" DIAMETER FOOTING WITH 8" THICK MINIMUM READY-MIX
CONCRETE BELOW BOTTOM OF LOWER COLUMN WITH ADDITIONAL
READY-MIX TO TOP OF 218M STILT (9"-+). PLACE CONCRETE
BELOW AND ABO'VE BOTTOM OF LOWER COLUMN IN ONE OPERATION,
18"R - 18" DIAMETER FOOTING WITH 8" THICK MINIMUM READY-MIX
CONCRETE BELOW BOTTOM OF LOWER COLUMN WITH ADDITIONAL
READY-MIX TO TOP OF 218M STILT (9"-+). PLACE CONCRETE
BELOW AND ABOVE BOTTOM OF LOWER COLUMN IN ONE OPERATION.
30"R- 24" DIAMETER FOOTINg WITH 13"THICK MINIMUM READY-MIX
CONCRETE BELOW BOTTOM OF LOWER COLUMN WiTH ADDITIONAL
READY-MIX TO TOP OF 230M STILT (9"-+). PLACE CONCRETE
BELOW AND ABOVE BOTTOM OF LOWER COLUMN IN ONE OPERATION,
ROUGH OPENING SCHEDULE
UNIT SYMBOL
WIDTH HEIGHT
FROM LEGEND
[] 38 1/4" 81"
SCALE:
16r
CUTCHOGUE, NY
O
7
Jl I :,'
g
~RAWN BY: BISHOP
DA TE: 12/08/09
CHECKED BY. RM
DA TE: 12/10/09
REVISEDDAI'E: JB 04/20/10
REVISED DATE -
REVISED DATE; ....
EV/SED DARE: ....
oz'r, S0. ~,a
SCALE: AS NOTED
SHEET NO.
SloES1
TRUSS LOCATION DIMENSIONS
TRUSS/BRACING PLAN
2x4 BEV. PURLIN
TOE NAIL OVERHANG
RAFTER TO OVERHANG
NAILER WITH (f) 16d R.S.
NAIL EACH SIDE
OVERHANG FRAME
2x6 OVERHANG NAILER
DETAIL A
SCALE: 1 1/2"= IL0''
-- 48'- 2x10 (NO,1 SYP)
END RAFTER ASSEMBLY
(7) 20d R.S. NAILS
~NER COLUMN
TRUSS/BRACING PLAN LEGENID
4~- 48,' 2090 R.C. TRUSSES @ 7'~6" O.C.
2 - 48 END RAFTER ASSEMBLY
- 2x4 TRUSS TIES @ 4'-0" O,C, , ,,
- 2x6 DIAGONAL END BRACES @ 8 -00.C,
(TO EXTEND TO FIRST TRUSS IN FROM ENDWALL)
CENTER 2X4 SYP WEB
STIFFENER ON TRUSS
WEB & NAIL WITH 3 1/2"
HDG R.S. GUN OR 16d
R.S. NAILS WITHIN 4" OF
STAGGERED
2x4 WEB STIFFENER SECTION A
SCALE.: 1 1/2"= 1'-0"
3.953
SCALE: ~ I
DETAIL B
~4-20d R,S. NAILS
PER CONNECTION
~ 2x6 END COLUMN
EXTENSION OR UPRIGHT
ASSEMBLY NAILED TO END
RAFTER ASSEMBLY AS
SHOWN AND TO EACH
INTERSECTING WEB. FASTEN
TO HEADER AND FRAMING
MEMBER WITH (2) 16d R.S.
NAILS iNTO EACH END
COLUMN EXTENSION
MEMBER OR UPRIGHT.
SCALE: I 1/2"= 1L0''
6~ i20d R.S. NAILS
PER CONNECTION
2-2x8 END COLUMN
EXTENSION OR UPRIGHT
ASSEMBLY NAILED TO END
RAFTER ASSEMBLY AS
SHOWN AND TO EACH
INTERSECTING WEB. FASTEN
TO HEADER AND FRAMING
EMBER WITH (2] 16d R.S.
NAILS INTO EACH END
COLUMN EXTENSION
DETAIL C MEMBER OR UPRIGHT,
SCALE: 1 1/2"= 1'-0'~
TRUSS SPACING 7'-6" C.C.
LIVE LOAD 17 PSF
DEAD LOAD 4 PSF
CEILING LOAD PSF
TOTAL LOAD 21 PSF
EB
STIFFENERS
4.042
CUTCHOGUE, NY
II I
7
~DRA WN BY; 51SHOP
DATE: 12/08/09
CHECKED 8~ ~M
DA TE: 12/10/09
REVISED DATE: JB 04/20/10
REVISED DATE: ---
47- 9- 0
48' R.C. 2090 TRUSS
SCALE: 3/8" = 1 '-0"
ISCALE:AS NOTED
SHEET NO.
S2oP S1 1
52'-6"
4,8' WIDE
(ZONE 2 & 3)
DESIGN AND EXPLANATORY
NOTES
1 .} EXTERIOR DOOR AND WINDOW LOCATIONS ARE TAKEN FROM THE
EXTERIOR FACE OF THE NAILERS AND ARE TO THE CENTER OF THE
DOOR AND WINDOW UNITS. VERIFY ALL DOOR, WINDOW,
SKYLIGHT AND SIDELIGHT LOCATIONS WITH THE OWNER.
2.) * - STITCH SCREW ROOF STEEL LAP RIBS 4 L,F. FROM EACH
ENDWALL W/#9x "S.S.I.D. SCREWS W/WASHERS. SEE SHEET S8 OF
511 FOR DETAILS.
~(
.I
4,8' WIDE
(ZONE 5)
4.8' WIDE
J (ZONES 2 & 3}
95.4' WIDE (ZONE 4(
EAST ELEVATION
(ZONE 2 & 3)
4.8' WIDE
(ZONE 5)
12
4.8' WiDE
(ZONES 2 & 3)
(ZONE 2 & 3) I 4~f
4.8'W~DE I ~4.8'W~DE
(ZONE 51 NORTH ELEVATION (ZONESI
4.8' WIDE 4,B' WrDE
SOUTH ELEVATION
FUNCTIONAL CUPOLA
(ZONE 2 & B]
IZONE 2}
4E 4 6~6E
Reference
Corner
(ZONE
4.8' WIDE
(ZONE 2 & 3}
t
4.8' WIDE ~
(ZONE 5) 41 '-3"
95,4' WIDE (ZONE 4)
WEST ELEVATION
dNSCOT
T# 167 BASE TRrM
· GU~FERS
[DING
CORNER TRIM
TRIM
INSCOT
BASE TRIM
CUTCHOGUE, NY .
cfi
n
III
III
I
I I I
DRA WN B Y: BISHOP
DA TE: 12/08/09
CHECKED BY: RM
DATE: 12/10/09
~'EVISED DATE: JB 04/20/10
· SCALE;AS NOTED ~
J
SHEET NO.
S3oE S1 1
~) FLUOROFLEX HI-RIB STEEL
(NO, 2 SPF)
HEADLOK 0,19" x, 6" FLATHEAD LAG SCREW
2x4 BEV. P
FILLER STRIP
B" O.G. GUTEERS
T# 144 & 146 FASCIA TRIM
~ ~ SOPF~T
HI-RIB/SOPFIT CAP
2x6 OVERHANG NAILER
(~) (2) 1/2"x$ 1/2" M. BOLTS &
(8) 20d R.S. NAILS
4B' 2090 R.C. TRUSS
~ KYNAR HI-RIB STEEL
GRADE TO HEEL
'F
18" LOWEST
MEMBER CUT-OFF
FINISH GRADE
( 3 ) ROWS 2x6 NAILERS (2100 MBR SPF) ~
-2x6 LAMINATED COLUMN
CAL BLOCKING
AT COLUMN LOCATION
167 TRANSITION TRIM
NAR HI-RIB STEEL WAINSCOT
'16" OSB PROTECTIVE LINER ~
T# 167 BAS E TRIM
) ROW 2x8 TREATED SFLASHBOARD
5" CONCRETE FLOOR~.
81M BASE ANCHOR
4" MINIMUM COMPACTED GRANULAR BASE
218M (14 GA.) COLUMN STILT (~
8" THICK MINIMUM READY-MIX CONCRBTE
BELOW BO~-OM OF LOWER COLUMN WITH
ADDITIONAL READY-MIX TO TOP OF 21 BM STILT (9"J:).
PLACE CONCRETE BEbOW AND ABOVE BOTFOM OF
LOWER COLUMN IN ONE OPERATION.
SIDEWALL SECTION A
.SCALE: 1/2"= 1'-0"
IN COLUMN
SADDLE
ED COLUMN
STILT ISOMETRIC
DESIGN AND EXPLANATORY NOTES
I ,) ~. THE PRECEDING SYMBOL IDENTIFIES ITEMS THROUGHOUT THE PLANS THAT ARE
NOT PROVIDED BY MORTON BUILDINGS, INC. OR MORTON BUILDINGS'
SUBCONTRACTORS AND ARE THE OWNER'S RESPONSIBILITY.
2,) FOOTINGS ARE DESIGNED FOR A 2000 PSF SOIL BEARING CAPACITY. LOCAL
CONDITIONS MAY REQUIRE MODIFICATIONS.
3.) CONCRETE FLOOR NOTES:
a. 3500 PSI, 5 1/2 BAG MIX CONCRETE
b, SLOPE GRADE AWAY FROM BUILDING @ 1" PER FOOT FOR A MINIMUM
DISTANCE OF 10' PLUS OVERHANG WIDTH
c A VAPOR RETARDER IS NOT MANDATED PER IBC SECTION 1910 EXCEPTION 3.
UNLESS THE FLOOR WILL BE COVERED BY MOISTURE SENSITIVE FLOORING
MATERIALS OR IMPERMEABLE FLOOR COATINGS OR WHERE THE FLOOR WiLL
BE IN CONTACT WITH ANY MOISTURE SENSITIVE EQUIPMENT OR PRODUCT
d. CONTRACTION JOINTS UNIFORMLY SPACED 15' O.C, OR LESS
INTERIOR
EXTERIOR
NAIL KEY
0.148" X 4" (2Od) NAILS
0.131" X 3 1/2" HOT DIPPED GALVANIZED (HDG} RING SHANK NAILS
3-2x6 COLUMN SPLICE FASTENING DETAIL
SCALE: 1/2" = 1'-0"
-2x6 LAMINATED COLUMN
1/4"xl 1/4"xl 4 GA. SUPPORT ANGLE
FASTENED TO COLUMN AT EACH
CORNER WITH (3) .I 48"f~ x 2"
STAINLESS NAILS. (12 TOTAL NAILS
PER COLUMN)
14 GA. CHANNEL WITH 1/4" PLATED
RIVET TO SUPPORT ANGLE
UNDISTURBED SOIL
STILT INSTALLATION
1. INSTALL PRESSURE TREATED
LOWER COLUMN WITH STILT IN THE
AUGERED HOLE,
2. POUR 9" MINIMUM THICKNESS OF
READI-MIX CONCRETE INTO THE
HOLE AS SPECIFIED.
3. BACKFILL AND COMPACTTHE
ANNULAR SPACE AROUND THE
COLUMN TO GRADE WITH SOIL
AUGURED FROM THE SITE.
~~- 3/16"X3/4"x3B" H.R, FLAT STEEL
(4) 0.177"x2.25" STAINLESS STEEL
ANCHOR NAILS PER STRAP
BUILDING COLUMN
81M BASE ANCHOR
FASTENING DETAIL
SCALE: 1 1/2"= 1'-0"
CUTCHOGUE, NY
n ~
CD
III
II I
7
III
~RAWN BY! BISHOP
DA TE: 12/08/09
CHECKED BY: RM
DA TE; 12/10/09
REVISEDDATE; JB 04/20/10
REVISED DATE; ~ -
REVISED DATE: ---
REVISED DATE: ---
ozl-. ¢.o, ~'~
SCALE: AS NOTED
SHEET NO.
S4oFSl
GABLE PURLIN
2x6 FASCIA
FLOUROFLEX HI RIB STEEL
2x4 PURLINS @ 23" O.C. Q
(NO. 2 SPF)
T~ 194 TRIM
HbRIB/SOFFIT CAP TRIM
48'- 2x10 (NO.1 SYP)
END RAFTER ASSEMBLY
KYNAR HI-RIB STEEL
2x6 ADDITIONAL NAILER
2x4 TRUSS TIE
14'-0"
GRADE TO HEEL
18" LOWEST
MEMBER CUT-OFF
FINISH GRADE
18M (14 GA.) COLUMN STILT
MINIMUM READI-MIX CONCRETE
BELOW BOTTOM OF LOWER COLUMN WITH
ADDITIONAL READI-MIX TO TOP OF 218M STILT (9"_+}.
PLACE CONCRETE BELOW AND ABOVE BOTTOM OF
LOWER COLUMN IN ONE OPERATION.
ENDWALL SECTION B
SCALE: 1/2"= 1'-0"
0.135" x 2 1/4" R.W. NAILS OR 16d R.S. NAILS
( 11 20d R,S, NAIL THROUGH STRAP
& INTO BRACE
2' END BRACE STRAP W/PRE-PUNCHED
HOLES (BEND TO FIT) FASTENED W/
(3) 0.140 x 1 1/2" R.S. NAILS
2x6 DIAGONAL BRACING FASTENED
TO COLUMN W/(4) 16d R.S. NAILS
48' 2090 R.C. TRUSS
2x4TRUSS TIE ~
60d R.S. NAIL
LOWER TRUSS CHORD
( I ) #9xl" TRU-GRIP SCREWS ON PEAK SIDE AND ~ ~
(2) ON EAVE SIDE IN HOLES SHOWN.
(JOINT MUST BE TIGHT BEFORE FASTENING CLIPS)
J
20 ga. GALVANIZED
PURLIN CONNECTOR
2x4 TRUSS TIE DETAIL
ADDITIONAL 2x6 NAILER
20d R.S. NAIL THROUGH
STRAP INTO TIE ,
(3) I 1/2" R.S. NAILS THROUGH STRAP 2 LONG ,END. BRACE STRAP
/4 R.W. NAILS
2x4 TRUSS TIE -~' ~
2x4 TRUSS TIE TO ENDWALL DETAIL
28-0839
CUTCHOGUE, NY
n
_n
CD
II I
III
'DRAWNBY: ~ISHOP ·
CHECKED B ~M
DA TE`' 12/10/09
REVISED DAPE: JB 04/20/10
REVISED DAT~' ---
,REVISED DArk' ....
SCALE,. AS NOTED
SHEET NO.
S5o Sl l
12) 60d R.S. NAILS IN OVERHANG RAFTER
2x4 PURLIN CUT TO FIT BETWEEN OVERHANG FRAMES
14'-0"
GRADE TO BOTIOM
OF TRACK GIRT
T,U,'71 TRACK COVER
51M TRACK
3x4 TRACK BLOCK
1 '1/2'~2" BLOCK & T#74
T#23 JAMB TRIM
LATCH HANDLE
48' 2090 R.C. TRUSS
340LTRUSS HANGER WITH 04) 1 1/2" R.S. NAILS
& (1) 1/2"x2 1/2" M. BOLT
5 1/4"xl 6 1/2" GLU-LAM HEADER (2400lb}
2x8 HEADER )NO. 1 SYP)
3 2x8 LAMINATED JAMB COLUMN
BEYOND WITH AN ADDITIONAL 2x8
TREATED LAMINATE FOR HEADER
SUPPORT FROM 1 '-0" BELOW GRADE
TO 15" ABOVE HEEL HEIGHT
2x3 JAMS (BEYOND --
BOTTOM 2' TREATED)
SLIDING DOOR HEADER SECTION C
SCALE: 1' = 1' 0"
WIDTH OF
SEAM PLUS 1/4" FOR TRUSS HANGER
HANGER TO
BEAM WITH [10} 20D R.S. NAILS
(PLACE NAILS IN ALL HOLES PROVIDED).
/4r'Xl 6 1 /2" GLU--LAM HEADER (2400 lb)
2X8 GiRT (NO. 1 SYP)
TRUSS
S HANGER
FASTEN 340L TRUSS HANGER TO TRUSS WITH
(1) 1/2"x2 1/2" M. BOLT & (14} 1 1/2" R S. NAILS
(PLACE NAILS IN ALL HOLES PROVIDED}.
TRUSS HANGER ISOMETRIC DETAIL
(5 1/4"xl 6 1/2" GLU-LAM HEADER WITH 340L TRUSS HANGER)
TOP OF BEAM HANGER
SITS DOWN ON SQUARE
CUT COLUMN
NAIL HANGER TO BEAM
FROM INSIDE WITH (3)
S,S. COLUMN ANCHOR NAILS
3-2x8 LAMINATED COLUMN --
NAIL 2xE GIRT TO BEAM
WITH 20d GUN NAILS
@ 4" O,C. STAGGERED
DESIGN AND EXPLANATORY NOTES
1 .} DOOR HEIGHT -- HEEL H EIGHT. JAMB COLUMN CUT-OFF HT.: 15" ABOVE HEEL HEIGHT.
NAIL BEAM HANGER TO COLUMN
FROM OUTS]DE WITH (3) S.S. COLUMN
ANCHOR NAILS
GLU-LAM BEAM
ADDITIONAL TREATED LAMINATE
INSIDE VIEW
BEAM HANGER
OUTSIDE VIEW
*NOTE: VIEWS ARE SHOWN WITH 1 '-0" OVERHANGS
(12) 20d R.S. NAILS
5 1/4" GLU-LAM JAMB DETAILS
CUTCHOGUE, NY
n
O
O
7
Jll~
g
II I
~DRAWNBY: BISHOP ·
DA TE: 12/0B/09
CHECKED BY. RM
DATE: 12/10/09
REVISED DATE: JB 04/20/10
REVISED DATE' --
REVILED DATE: --
P, EVISED DATE: --
· SCALE;AS NOTED
SHEET NO.
· S6oFS1
3-2x8 LAMINATED JAMB
COLUMN WITH LAMINATE (BEYOND)
3-2x8 LAMINATED
COLUMN WITH LAMINATE
VERTICAL 'I" RAIL
LATCH HANDLE
47E A/S LATCH STRIKE PLATE
HORIZONTAL --
INTERMEDIATE "[" RAILS
JAMB DETAIL
Ill
GRADE
CENTER DOOR GUIDE
148 A/S DOOR GUIDE HAS A BUILT-IN STOP
FOR ALUMASTEEL DOORS SO STUB COLUMN
MUST BE EXACTLY CENTERED IN DOOR OPENING
DOOR GUIDE DETAILS
RAIL THICKNESS CHART
STANDARD -- -- HEAVY
VERTICAL HORIZONTAL VERTICAL HORIZONTAL
WEB FLANGE WEB FLANGE WEB FLANGE WEB FLANGE
,070" ,090" .060 ,080 ,O9O , 50 .080" . 30'
DOUBLE TOP "D" RAIL
(16 GUAGE)
HORIZONTAL 'T' S.S. RAIL
(0.06" WEB, 0.13," FLANGE)
HORIZONTAL 'T' /
INTERMEDIATE RAIL
(0.06" WEB, 0.13" FLANGE)
VERTICAL 'T' RAILS
(0.89" WEB, 0.15" FLANGE)
13E LATCH ROD
CENTER DO~OR GUIDE
STRUT
(0.09" WEB, 0.15" FLANGE}
LATCH
(16 GUAGE)
22'-6" x 14' DOUBLE SLIDING DOOR FRAME
(TWIN PANEL)
1264 8" HOOK
HORIZONTAL "1"
INTERMEDIATE RAIL
INSTRUCTIONS
1,SCREW NUT ONTO HOOK.
2. SCREW HOOK INTO LATCH BODY,
TRACK GIRT
CUTCHOGUE, N~Y _
III
III
7
II I
~DRAWN BY: BISHOP
DA TE: 12/08/09
CHECKED B)C RM
DA TE: 12/10/09
REVISEDDA[E: JB 04/20/10
REVISED DATE: ----
REVISED DATE: ----
REVISEDDArE ....
13E LATCH ROD --
LATCH ROD DETAIL
1265 JAi
LATCH HANDLE
'f
· SCALE: AS NOTED
SHEET NO,
· S7o~S1
'3'd'dflO~9 9NI;~:I:INIgl , ,,I ~.L3:I/IH3;~V N91~:I(:] C]:::II11V
AN
ONI (:]61VAZl NIA
0
za~
~ 0
0
_z
qo
2x4 F
4.8' WIDE
{ZONE 2 & 3}
48' WIDE BUILDING PURLIN LAYOUT
SCALE: 1/2"= 1'-0'
4.8' WIDE
)ZONE 2 & 3)
2X4 PURLIN
HEADLOK .I 9"x6.0" FLATHEAD LAG SCREW
{ICC-ES REPORT ESR 1078)
(1) #9x]"TRU-GRIP SCREW ON PEAK SIDE AND ·
(2) #9Xl" TRU-GRIP SCREWS ON EAVE SIDE OF
PURLIN IN HOLES SHOWN I JOINT MUST BE TIGHT
BEFORE FASTENING CLIPS
2x4 BUTTED PURLIN DETAIL
(PURLIN CONNECTED WITH
6" HEADLOK FLATHEAD LAG SCREW)
SCALE: 1 1/2"= 1'-0"
4.8' WIDE
{ZONE 2 & 3)
- INDICATES PUR,,LINS TO, BE FASTENED
O w/HEADLOK.19 x6.0 FLATHEADLAG
SCREW.
4.8' WIDE
{ZONE 2 & 3)
O- INDICATES PUR,,LINS TO, BE FASTENED
w/HEADLOK .19 X6.0 FLATHEAD LAG
SCREW, ALL OTHER PURLINS TO BE
FASTENED w/60d R,S, NAIL
48' WIDE BUILDING PURLIN LAYOUT
SCALE: 1/2" = 1'-0"
20 GA. GALVANIZED (~)
PURLIN CONNECTOR
60d R.S. NAIL
(1} #9xl '~TRU-GRIP SCREW ON PEAK SIDE AND
(2} #9x1" TRU-GRIP SCREWS ON EAVE SIDE OF
PURLIN IN HOLES SHOWN (JOINT MUST BE TIGHT
BEFORE FASTENING CLIPS
20 GA. GALVANIZED (~)
PURLIN CONNECTOR
2x4 BUTTED PURLIN DETAIL
{PURLIN CONNECTED WITH 60D P.S. NAIL)
SCALE: 1 1/2"= 1'-0"
CUTCHOGUE, NY
n
O
CD
II I
III
7
III
DATE: 12/08/09
CHECKED BY SM
DA TE: 12/10/09
REVISEDDAI'E: JB 04/20/10
REVISED DATE.. .---
,REVISED DATE,' --
04, 2c~, ~
SCALE: AS NOTED ~
J
SHEET NO.
S9o~ S1 1
CUPOLA CAP ~
ROOF
~ CUPOLA SIDE
FRAME
IPOLA SUPPORTO
BASE BLOCK~
)LA BLOCKS
~AMING CLIP~)
CUPOL/
KYNAE
2x4 PURLINS
CENTERLINE OF CUPOLA
FIRST ROW
2x4 PURLINS
PEAK PURLIN
TRUSS
.BLOCKSj
CUPOLA FRAMING DETAILS
SCALE: I" = 1L0"
TOP CHORD OF
END RAFTER ASSEMIBLY
2x6 NAILERS
EXTRA NAILERS AD[DED
BETWEEN STD. NAILIERS ~
(MAX. SPACE TO BF: 24"}
.~(2x6 BLOCK BETWEEN NAILERS
NAILED TO COLUMN W/20d
GUN NAILS. NAILED 4" O,C.
LAMINATED COLUMN
OSB SHEARWALL DETAIL
SCALE' 1/2"= 1'-0"
:HORD OF
END RAFTER ASSEMBLY
COLUMN BETWEEN NAILERS
NAILED W/1-3/4" RING SHANK
COIL GUN NAILS SPACED 4" O.C.
NAILED TO INTERMEDrATE
SUPPORTS W/1-3/4" RING SHANK
COIL OUN NAILS SPACED 6" O.C.
INATED COLUMN
(IF PROTECTIVE LINER IS INCLUDED)
BOARD
7/1 6" OSB SHEARWALL ELEVATION
SCALE: 1/2"= IL0"
CUTCHOOUE, NY
n
7
D~AWN BY: BISHOP
DATE: 12/08/09
CHECKED BY: RM
DATE: 12/10/09
REVISED DATE,' JB 04/20/10
REVISED DATE,. ....
,~ E VISED DATE,. ....
REVISED DATE,' ....
04,9.0, ~
SCALE:AS NOTED
SHEET NO,
S10o~ S1 1
ROOF STRUCTURE FASTENING SCHEDULE
(~) VENT-A-RIDGE TO BASE TRIM #9 x 1" STAINLESS STEEL RUBBER WASHER PANHEAD IN~rERNAL DRIVE SCREWS @ 8" D.c.
~) RIDGE BASE TRIM TO 2x4 PURLINS #9 x 2" STAINLESS STEEL RUBBER WASHER PANHEAD INTERNAL DRIVE SCREWS AT EVERY HI-RIB (1 '-0" D.C.}
(~) HI-RIB STEEL TO 2X4 PURLINS #9 x 2" ZINC PLATED RUBBER WASHER PANHEAD INTER!NAL DRIVE SCREWS AT EVERY HI-RIB (1 '-0" D.C.)
(~t 20 go, GALVANIZED PURLIN CONNECTORS #9 x 1" TRU-GRIP SCREWS
(~) 2x4 PURLINS TO TRUSS {INTERIOR ZONES) 0.200" x 6" (60d) RING SHANK NAILS IN PRE-DRILLED HOLE
(~) 2x4 PURLINS TO TRUSS (EXTERIOR ZONES) I HEADLOK ,19"x6.0" FLATHEAD LAG SCREW IN PRE-DRILLED HOLE
~) 48' STRAIGHT CHORD TRUSS TO COLUMN (2) 1/2"x51/2"M.BOLTS & (8) 0.177" x 4"120d) RING SHANK NAILS
(~) HI-RIB STEEL STITCHING #9 x 1" STAINLESS STEEL RUBBER WASHER PANHEAD INTERNAL DRIVE SCREWS IN LAP RIBS BETWEEN PURLINS
WALL FRAMING FASTENING SCHEDULE
~) COLUMN STILT (14 GA.) TO COLUMN (12) 0.148" x 2" (6d) STAINLESS STEEL RING SHANK NAIL,S
O 81M BASE ANCHOR TO COLUMN 0.177" x 2-1/2" STAINLESS STEEL NAILS (4) PER ANCHORI
~) 2x8 SPLASHBOARD TO COLUMN (4) 0.177" x 4" (20d) STAINLESS STEEL RING SHANK NAILS @ SPLICE/ (6) 0.] 77" x 4" I20d) RING SHANK NAILS @ STANDARD CONNECTION
(~ 2x6 NOTCHED NAILER TO COLUMN (4) 0.148"x 3-1/2" (16d) NAILS @ SPLICE/16) 0.148" x 3-1/2" (16d) NAILS @ STANDARD CONNECTION
~ 7/16" BBB TO SPLASHBOARD & NOTCHED NAILER 0.099" x 1-1/4" ASBESTOS SIDING NAILS
~ 2x6 NAILER TO COLUMN (4) 0.148" x 3 1/2" (16dI RING SHANK NAILS @ SPLICE/(6) 0.148" x 3-1/2" (16dj RING SHANK NArLS @ STANDARD CONNECTION
~ END RAFTER ASSEMBLY TO 2x6 END COLUMN EXTENSIONS (4) 0.177" x 4" (2Od) RING SHANK NAILS
~ 2x4 PURLIN TO END RAFTER ASSEMBLY HEADLOK .19"x6.0" FLATHEAD LAG SCREW IN PRE-DRIL LED HOLE
(~ HI-RIB STEEL TO NAILERS #9x2~~TAiNLESSsTEELRUBBERWASHERP^NHEAD~NTERNALDRivEScREW$ATEvERYH~R~B(1L~''~~¢.~
~]~ SOFFIT TO WALL INSERTED IN PRE-FORMED SLOT IN SOFFIT/HI-RIB CAP
(~ SOFFIT TO FASCIA T-SO MONEL STAPLES (2} PER PIECE
<~ 7/16" BBB SHEARWALL
~} BBB TO PERIMETER BLOCKS/FRAMING 0.113" x1-3/4" RING SHANK COIL NAILS @ 6" B.C.
~) BBB TO INTERMEDIATE FRAMING 0.113" x1-3/4" RING SHANK COIL NAILS @
~ BLOCKS TO COLUMNS 0.131" x 3 1/2" HOT DIPPED GALVANIZED (HDO) RING SHANK NAILS @ 4" a.c.
SCREWED ROOF STEEL CUPOLA FASTENING
CUPOLA CAP TO CUPOLA ROOF (4J 1/4" x I" PLATED MACHINE BOLTS AND LOCK WASH]ERB
CUPOLA ROOF TO CUPOLA SIDES PRE-FORMED CRIMPED METAL CONNECTIONS AND (8)) #9 x 1" STAINLEBS STEEL RUBBER WASHER PANHEAD INTERNAL DRIVE SCREWS
CUPOLA SrDEB TO CUPOLA BASE FRAME #9 x 1 " STAINLESS STEEL RUBBER WASHER PANHEAD INT[ERNAL DRIVE SCREWS (4) PER SIDE (16) TOTAL
CUPOLA BASE FRAME TO BBB CUPOLA SUPPORT 1~7/8'' GUN NAILS @ 6" o.¢.
BBB CUPOLA SUPPORT TO TREATED BEVELED BLOCK 0.148" x 3-1/2" (16dj RING SHANK NArLS @ 8" B.C.
TREATED BEVELED BLOCK TO 2x4 CUPOLA BLOCKS 1/4" x 4-1/2" LAG SCREW W/ 1/4" FLAT WASHER AT EVEfRY HI-RIB (1 '-0" B.C.)
2x4 CUPOLA BLOCKS TO FRAMING CLIPS {2) 0.135" x 1 -I/2" RING SHANK NAILS
FRAMING CLIPS TO PURLINS (2) 0.135"x 1-1/2" RING SHANK NAILS IN SIDE OF PURLIBq AND (2) 0.135"x 1-1/2" RING SHANK NAILS IN TOP OF PURLIN
n
O
III
III
III
I
DP~A WN B Y; BISHOP
DATE: 12/08/09
CHECKED BY: RM
DA TE: 12/10/09
REV/$EDDAI'E; JB 04/20/10
REVISED DATE' ....
E~EV/$ED DATE;
04,.. 20 ,
SCALE:AS NOTED '~
J
SHEET NO,
S1 10;: S1 1