Loading...
HomeMy WebLinkAbout35054-ZFORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. BUILDING PERMIT COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 31465 Z Date SEPTEMBER 22, 2005 Permission is hereby granted to: JON C & JANIS E KERBS 440 RILEY AVE MATTITUCK,NY 11952 for : CONSTRUCTION OF A NEW SINGLE FAMILY DWELLING WITH COVERED FRONT ENTRY AS APPLIED FOR 'at premises located at 60105 MAIN RD County Tax Map No. 473889 Section 056 Block pursuant to application dated SEPTEMBER 15, 2005 Building Inspector to e~cpire on M3LRCH 22, Fees 91~.80 ~/ SOUTHOLD 0003 Lot No. 011 and approved bythe 2007. Authorized Signature ORIGINAL Rev. 5/8/02 FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 35054 Z Date OCTOBER 7, 2009 Permission is hereby granted to: RC SMITH FAMILY LLC 109 BAY AVE BAYPORT,NY 11705 for : CONSTRUCTION OF A NEW ONE FAMILY DWELLING WITH COVERED FRONT ENTRY AS APPLIED FOR. THIS PERMIT REPLACES BP 33291. at premises located at 60105 County Taxx Map No. 473889 Section 056 pursuant to application dated OCTOBER Building Inspector to expire on APRIL MAIN RD SOUTHOLD Block 0003 L~t No. 011 7, 2009 and approved by the 7, 2011. Fee $ 1,222.04 Authorized Signature ORIGINAL Rev. 5/8/02 FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 33291 Z Date AUGUST 2, 2007 Permission is hereby granted to: JON C & JAIqIS E KERBS 440 RILEY AVE MATTITUCK,NY 11952 for : CONSTRUCTION OF A NEW SINGLE FAMILY DWELLING W/ COVERED FRONT ENTRY AS APPLIED FOR.THIS PERMIT REPLACES BP # 31465 at premises located at 60105 MAIN RD County Tax Map No. 473889 Section 056 pursuant to application dated AUGUST SOUTHOLD Block 0003 Lot No. 011 2, 2007 and approved by the Building Inspector to expire on FEBRUARY 2, 2009. Fee $ 1,222.40 /~o~//~~~ g~ei ORIGINAL Rev. 5/8/02 FIELD INSPECTION REPORT i__ DATE J COMMENTS FOUNDATION (1ST) FOUNDATION (2ND) PLUMBING .... INSULATION PER ~. Y. STATE ENERGY CODE F~ ~DITION~ COMMENTS TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL SOUTHOLD, NY 11971 TEL: (631) 765-1802 FAX: (631) 765-9502 www. northfork.net/Southold/ Examined Approved Disapproved a/c q/2~ 2~, 20 of ,20of PERMIT NO. BUILDiNG PERMIT APPLICATION CHECKLIST Do you have or need the follo, win~,,.-~fore applying? Board of Health ~' 4 sets of Building Plans Planning Boar~.i~proval Survey_ Check Septic Form N.Y.S.D.E.C. Tmstees Contact: ~Z-~ I0~ Mail to: Building Inspector APPLICATION FOR BUILDING PERMIT rote INST.VCTIONS a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans, accurate plot plan to scale. Fee according to schedule. b. Plot plan showing location of lot and of buildings on premises, relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application, the Building Inspector will issue a Building Permit to the applicant. Such a permit shall fie kept on the premises available for inspection throughout the work. e. No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim, the Building Inspector may authorize, in writing, the extension of the permit for an addition six months. Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County, New York, and other applicable Laws, Ordinances or Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances, building code, housing code, and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. (Side"of applicant or na~e, if a ~'~oration) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumbgr or builder Name of owner of premises (As on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer (Name and title of corporate officer) Builders License No. Plumbers License No. Electricians License No. Other Trade's License No. Location of land on which proposed,work will be done: House Number Street Hamlet County Tax Map No. 1000 Section Subdivision (Name) Block '~ Filed Map No. 2. occupancy of proposed construction: State existing use and occupancy of premises and inter~d use and a. Existing use and occupancy "O O.._C~,- ~ b. Intended use and occupancy_ \ ,-~L W~- ~ 3. Nature of work (check which applicable): New Building Repair ~moval. Demolition 4. Estimated Cost 5. If dwelling, number of dwelling units If garage, number of cars Addition Alteration Other Work Fee (Description) (To be paid on filing this application) Number of dwelling units on each floor 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of existing structures, if any: Front tJ"x¢~-""J[~ Rear .Depth Heigh[ Number of Stories DepthDimensions of same structure Height with alterations or additions: Front Number of Stories 8. Dimensions of entire new construction: Front Height 9. Sizeoflot: Front 10. Date of Purchase Dec., 7 11. Zone or use district in which premises are situated Rear .Depth Number of Stories Rear dO .Depth {qq O Name of Former Owner ~L)\ [[(,.,,a 12. Does proposed construction violate any zoning law, ordinance or regulation? YES __ NO 13. Will lot be re-graded? YES NO?<- Will excess fill be removed,fi:om pr~nises? YES NO 14. Names of Owner of premises '--~O~'a"-~5~vl'r'Address kA.,~'~-Jm,-~._ ~HPhone No. (0 Name of Architect Address 'Phone No Name of Contractor Address Phone No. 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES__NO * IF YES, SOUTHOLD TOWN TRUSTEES & D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES__ NO * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey, to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. STATE OF NEW YORK) SS: '~---~)~ ~ ~,-" '~X e t/¥-.--' ~ being duly sworn, deposes and says that (s)he is the applic~t (Nme of individual si~ing ~ntract) a¢ove named, (S)Heisthe &~ ~ ~ (Contractor, Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are tree to the best of his knowledge and belief; and that the work will be performed in the manner set forth in the application filed therewith. 80#~1£ J. DOROSKI Public, Stst~ Of #ew~bdl 01D06095328, $uffolk,¢~ Term~imsJulyT, 20 ¥ ~, TO Ion C. Kerbs 440 Riley Ave. M~a~tuck NY 11952 FORM NO. 3 TOWN OF SOUTHOLD B~ DEPARTMENT -~fOUTHOLD, N.Y. NOTICE OF DISAPPROVAL DATE; March 5. 2001 Please take notice that your applicalion dated Jananrv 2. 2001 For permit for lot creation (with e,~tln~ smicture) Location ofproperty 60105 Main Rd Southold County Tax Map No. 1000 - Section 56 Block3 Lot II SubdiVision Filed Map ~ Lot # Is returned herewith and disapproved on the following grounds proposed set-off not ~rmitted nusuam to Article XV Section 100-151which states; Except as otherwise t~rovided in this chanter, no bnildin~ or premises shall be used or occuviecl and no bnildin ~, 6r structure or part thereof shall be erected or all~'i'ed in a use district unless the same conforms to the D~nsiW and Minim~lm Lot Size Schedules and the Bulk Schedules hereinafter set forth Bulk Saht,~lnle reoulres minimum lot size of 80,000 square feet in the R-80 zone. vrovosed setoff+/- 7500 sq. Not oerm/tted vursuant to Article XXIV Section 100-244B which requires a minimum ride yard setback on lots euntainin~ 7500 10 feet. Setback of existin~ su'ucmres will be +/- 2 feet on east and west;ooundaries. / Authorized~ature G~rard P. Goeb~in~er, Chairman James Din~zio, Ir. Lydia A. Tonora Lora S. Collins George Homing BOARD OF APPEALS TOWN OF SOUTHOLID Sou[hold Town Hall 53095 Main Road P.O. Box 1179 Sou[hold, New York 11971 ZBA Fax (631) 765-9064 Telephone (631) 765-1809 ~ ',,FINDINGS. DELtBERATIONSAND'DEfTERMINA~I'ION MEETING OF APRIL; 19. 2b01 Appl. No. 4926 A & B - ~J~N C. KERBS Locafiohof Propers: 80105 Main Road. Southo!d Parcel 1000-56-3-11 Date of, Pubitc Hearing., Apdl 5, 2001 FINDINGS OF FACT PROPERTY FACTS/DESCRIPTION; Applicant's property is located along the north side of the Ma n Rbad (a/k/a~Stete Route 25) in Southold The lot co~1~ists of 7500 sq ff. with 60 ft. frontage along the Main,Road and a.dapth of 125 feet. The property i~ improved with a one-story trailer and accessory freme, garege as shown on the survey map prepared by Anthony W. Lewandowski. L.S. dated October 2, 2000. BASIS OF APPEAL Building.Inspector's Notice of Disapp~va~ dated March 5, 2001 denying an application dated. January 2, 2001 for a permit for lot creafi~pn with existing structures, under the current regulations, A,..ticle XV, Section 100-151 for the re~son the lot does not meet the size requirement of the current zoning ordinance of 80,000 sq. fi. in the R-80 Zone, and A~cta XX1V, Section 100-244B for the reason the side yard setback of e~itsfing structures are ~ess than ten (10) feet AREA VARIANCE RELIEF REQUESTED: Applicant reques~ts area variances for a lot created in ~1~158, whiCh' sizeis less than 12,500 sq. fi. and,lot width of 11~0 feet, the minimum provided in Bulk SChedule AA for the time period between April 9, 1957 and D~:ember 1,197t~ Also requested are sethack variances fora'dwelling structure (trailer) which doe~ net meet the current code setbacks for a principal dwelling at 10 feet minimum on one side, and Ifor an accessory garage at less than three (3) feet from the property line for propel~ies containing 1/'500 sq. ff. INFORMATION AND EVIDENCE: Tt3e Zonin~l Board held a public hearing on April 5. 2001 on this matter, at which time written and.0ra! ;t~stimony~was presented. Based upon allltasflmony, documentation and other evide~ca, the Board finds the following findings of facts to boi true and relevant: A. The lot and trailer on it have existed since 1958 with ~o apparent harm or detriment to the community. No testimony was presented during the Rublic hearing to suggest that the size of the lot has had an adverse impact on the neighbdrhood or altered the character of the neighborhood during the 44 year~ of its existence. B. The lot was created by deed dated April 23 1958, wr~ich was recorded in the Office of the Suffolk C6~nt~ C ark on April 28, 1958 at L~ar 4453 I~age 73, Page 2- April- 19, 2001' ZBA App!~ No. 4926 - J. Kerbs R~.. 1000-~56-3-11 at South~ld C. Applicant's,. predecessor was issued a valid trailer permit, d~ted September 25, 1958, by th~. T0~I B,~i~, Town of Southold; t~.~naintair~ a ~t~iler on t~e k~t~ iP questiort, ~inc[e§~!r~ely~ unress~ ~ey ~oked'f,o¢ cause~" NO;. evidenc~ was prese~i~, to, Sugg~;t that: the,Tow~ Bbar~. sought'tO, revoke the ~ermit atany time during the 44 .years. D. The, applicOn, wishes tO mprove the. property ai3d has ag,reed to remove the tmilerwith n a reasonable'~fime. REASO,N~S~, FOR BOARD ACTION: On the basis of testimony presented, materials submitted and personatlnSpect~or~ the Board makes the following findings: 1. Grant 'of an area variance will not prods_me an undesirable change in the character of the heighbqd~.~ood or. a de~t~ent tp nearby properties. Use of th~ property as a nonconforming lot with a nonC°r~rming' structure has'~xisted since ~1958 with no detriment to the community Grant of the Vada~q~.wJll pmv de for the el ruination of the nonconforming tm er Wh ch wi pnhance and ' Improve ~e lot, .and therefore be a benernt to the surround ng properties and ne ghborflood. 2. The benefit sought by applicant cannot be achieved t~y some method, feasible for appellant to pursue, other'than area variances because the lot is substandard in size and the setback of the trailer is, pree~tihg; V~th~rt the variance, the trailer would remain on the lot indefinitely until it deterioreted~ and the tot:could not be improved. 3. The requested area vadance is substantial 4. Grarit of the variances will not have an adverse effect or impact on the physical or environmental conditidns in the Oeighborhood or district. No. evidence was presented to suggest that the physical or environm~ntat;conditions in the neighborhood would be adversely impacted. In considering this application, the Board deems this action to be the minimum necessary and adequate to enable applicar)t to enjoy the benefit of a new dwelling, replacing the existing nonconforming trailer; while at the same time preserving and protecting the character of the neighborhood, a~d the health, safety, welfare of the Community. BOARD RESOLUTION: Now, therefore, on motion by Chairman Goehdnger, seconded by Member DiniziO,,,it' was RESOLVED, to APPROVE the application as applied for, SUBJECT TO THE FOLLOWING CONDITIONS: 1. The applicant shall remove, the trailer from the property within three years of the date of this decision; 2. The applicant agrees to maintain the trailer in good condition so that it does not become ZBA Appl. bio. 4926-J. Kerbs Re: '1 ~00-56-~-1t at Southold deteriorated before it is removed, RECEIVED AND F~LED BY TH~ SOUTI'iOLD TO¥~N.C~ DaTE ¢/~/¢' z-Iotm /, :¢ ~ Tow~ Clerk, To~ of ~uth~d Town Hall Annex 54375 Main Road P.O. Box 1179 Southold~ New York 11971-0959 Telephone (631 ) 765-1802 Fax (631 ) 765-9502 BUILDING DEPARTMENT TOWN OF SOUTHOLD /darch 13th, 2009 /kC Smith Family LLC 109 Bay Avenue Bayport, N.g. 11705 /kE: 60105/koute 25 {Construction of New Dwelling) 5CT/d: # 56. -3-11 To ~Vhom it/day Concern: P/ease be advised that your Building Permit # 33291 issued August 2nd, 2007 has expired According to the Code of the Town of 5outho/d, a Certificate of Occupancy must be issued before the use of the structure. To renew your Building Permit, please submit a fee of $1222.~.~,,, ~at that time, = ~ we can schedule an inspection by one of our Building Inspector~ " 's. / ~ ,d J [ ¥I ~ If you have any questions, p/ease ca// us at 76§-1802.^ r~'~t. .z SOUTHOLD TO~N BUILDING OEPT ~ Southold Town Building Department P.O. Box 1179 54375 Main Road Southold, New York 11971 (631) 765-1802 Parcel 1D: 56.-3-11 Permit #: 35054 Permit Date: 10/7/2009 Expiration Date: 4/7/2011 BUILDING PERMIT RENEWAL LETTER Dated: 7/6/2012 Applicant: Location: Work Description: RC SMITH FAMILY LLC 60105 MAIN ROAD SOUTHOLD SINGLE FAMILY DWELLING CONSTRUCTION OF A NEW ONE FAMILY DWELLING WITH COVERED FRONT ENTRY AS APPLIED FOR. THIS PERMIT REPLACES BP 33291. A FEE OF $612.02 IS REQUIRED TO RENEW THIS BUILDING PERMIT. Address: JON C. & JANIS E. KERBS 440 RILEY AVENUE MATTITUCK, NY 11952 The permit listed above has expired. Please contact our office as soon as possible to begin the renewal process. Ali work on the project must stop on the expiration date. No work is permitted or authorized beyond the expiration date. THANK YOU, SOUTHOLD TOWN BUILDING DEPT. N S TEST HOLE DATE: 11/05/02 00' SILTY LOAM (OL) (sw) (sw) NOTE AREA = 7,424- SQ. FT. VERTICAL DA3~JM = N,G,V. DATUM (M.S.L. 1929) J Abandonment of uxisting sanitary system J to be witnessed by % . Yot~g & Young 400 Os~ra~der Avenue, R~verhead, New York 1190! B3~-727-2303 Alde-~ ~'. Young, P.E. & L.S. (190B-1994) Howard ~. Y~g, Land Su~ey~ TK~ C. ~olp~, Profes~o~l Engineer Robert C. T~t, Architect HFAI TH DFPARTMFNT IISF SURVEYOR'S CERTIFICATION · WE HEREBY CERTIFY TO ~ON C. KERB~ & ~ANI~ E. KERBS ~AT ~lS SURLY WAS PREPARED IN ACCORDANCE ~ THE CODE OF PRAC~CE FOR LAND SUR~ AD~D BY ~E NEW YORK STA~ ASSOClA~ON OF PROFESSIONAL LAND SURVEY FOR JON C. KERBS &: JANIS E. KERBS At Southold, Town of Southold Suffolk County, New York County Tax Map 9i,t,i~t 1000 Section 056 BIo~tk 03 Lot 11 BUILDING PERMIT SURVEY J ADDED BUILDING PERMIT DATA MAP PREPARED DEC. 20, 2002 NOV. 12, 2002 JULY 22, 2002 SCALE 1" = 40' JOB NO. 2002-0541 DWG. 2002_0541_bp Permit Number REScheck Compliance Certificate Ch ed By/Oate New York State Energy Conservation Construction Code REScheck So~wa'e Version 3.6 Release 2 Data 81ename: C:\Program Files\CheckLRESchcck\KERBS.rck PROJECT TITLE: PROPOSED HOUSE COUNTY: Su~lk STATE: New York IH)D: 5750 CONSTRUCTION TYPE: Detached 1 or 2 F~nily HEATING TYPE: Non-Electric WINDOW / WALL RATIO: 0.15 DATE: 09/22/05 DATE OF PLANS: 09/2005 PROJECT DESCRIPTION: KERBS RESIDENCE MAIN ROAD SOUTHOLD, NY COMPLIANCE: Passes Maximum UA = 379 Your Home UA = 362 4.5% Better Than Code (UA) Gross Glazing Area or Cavity Cont. or Door P~m~er R-Value R-Vflue U-Factor UA Ceiling 1: Flat Ceiling or Scissor Tress 1108 30.0 0.0 39 Wall 1: Wood Fra'ne, 16" o.c. 1136 13.0 0.0 76 Window 1: Wood Frame:Double Pane with Low-E 133 0.350 47 Window 2: Wood Frame:Double Pane with Low-E 26 0.330 9 Door h Solid 21 0.280 6 Door 2: Solid 14 0.300 4 Door 3: Glass 21 0.320 7 Wall 2: Wood Frmne, 16" o.¢. 1136 13.0 0.0 80 Window 3: Wood Frame:Double Pane with Low-E 156 0.350 55 Window 4: Wood Frame:Double Pane with Low-E 5 0.300 2 Floor 1: All-Wood Joist/Truss:Over Unconditioned Space 1108 30.0 0.0 37 COMPLIANCE STATEMENT: The proposed building represented in this document is consistent with the building plans, sped~cations, and other calculations submitted with this permit application. The proposed systems have been designed to meet the New York State Energy Conservation Construction Code requirements. When a Registered Design Pmi~sional has stamped and signed this page, they are attesting that to the best ofhisfher knowledge, belief and prol~asiooal judgment, such plans or RlOqckeclc Inspection Checklist New York State Energy Conservation Construction Code REScheck Sofware Version 3.6 Release 2 DATE: 09/22/05 PROJECT TITLE: PROPOSED HOUSE Bld~ Dept. Use [ I [ ] [ ] [ ] [ I [ ] [ ] [ ] [ ] [ ] [ I Ceilings: 1. Ceiling 1: Flat Ceiling or Scissor Tress, R-30.0 cavity insulation Comments: Above-Grade Wails: 1. Wall 1: Wood Frame, 16" o.o., R-13.0 cavity insulation Comments: 2. Wall 2: Wood Frame, 16" o.c., R-13.0 cavity insulation Comments: Windows: t. Window 1: Wood Frame:Double Pane with Low-E, U-fictor: 0.350 For windows without labeled U-~hctors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ Comments: ] No Window 2: Wood Frame:Double Pane with Low-E, U-~ctor: 0.330 For windows without labeled U=fictors, describe f~atures: # Panes Frame Type Thermal Break? [ ] Yes [ Comments: ] No Window 3: Wood Frame:Double Pane with Low-E, U-fictor: 0.350 For windows without labeled U-t~'tors, describe l~tures: # Panes Frame Type Thermal Break? [ ] Yes [ Comments: ] No Window 4: Wood Frame:Double Pane with Low-E, U-f~ctor. 0.300 For windows without labeled U-~ctors, describe f~mn'es: # Panes Frame Type Thermal Break? [ ] Yes [ Comments: ] No 1. Door 1: Solid, U-~ctor. 0.280 Comments: 2. Door 2: Solid, U4~ctor. 0.300 Comments: 3. Door 3: Glass, U-~ctor. 0.320 Comments: 1. Floor 1: All-Wood Joist/Truss:Over Unconditioned Space, R-30.0 cavity insulation Comments: b5.00' 25.00' 2 STY. b7,00i _ 18.00'~i ~ 24.4' APPROVED AS NOTEr DATE: ~._~ 8.P.# ~'~ FEE: NOTIFY BUILDING 765-1802 8AM TO 4PM FOLLOWING INSPECTIONS: I. FOUNDATION - ~0 3. INSU~TION 4. FINAL - CONSTRUCTION BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL REQUIREMENTS OF ~E, YORK STATE. NOT DESIGN OCCUPANCY OR USE IS UN~WFUL WITHOUT CERT OF OCCUPANCY LOT A~EA: 3424.~ ~.F. ~ ~E REQUIREMENTS OF THE' ~DES OF NEW YORK STATE. CERTIFICATION OF HOUSE= ~lo~ 5.F, NAILING & CONNECTIONS REQUIRED. DO NOT PROOEED WITH FRAMING UNTIL SURVEY OF FOUNDATION LOCATION HAS BEEN APPROVED. UNDERWRffERS CERTtFICA~ ~EQURED "is) TO ~ ~N 45-10C Or- THE TOWN C~, PLUMBER CERTIFICATION ON LEAD,CONTENT; BEFORE CERTIFICATE OF OCC!J PANC Y SOLDER USED IN WATER SUPPL Y SYSTEM~C./ANNOT ~ EXCEED ~I_~. E~.~,Y~.LEAD. ~TT~ ~1 n~ PLUMBING ~ ~ ~ I L ~[~ ALLPLUMEINGWASTE .... ~ &WATERLINESNEED D~WN: M~ S~L~: 1"= iO'-~ST~O~,~ ~ S-1 REVISIONS: D~W~ ~S C~Y~ ) ~- _~W~ __ _ ~ ,-~ 2ND. ~OOR ~ ~ 0 FRO~T EEV~TIO~ SCAkE: 1/4,"= 1~-0" I , ~ .... -- = ~-- -.... ~~ LE~ ELEVATION '~.~,..~x~ A-1 SCALE: 1/q" = 1'-0'" FLOOR (MIN) 10~ 0" REAR ELEVATION SCALE: 1/4" = 1'-0" RIGHT ELEVATION mm mmmm DRAWN: MH / NS SCALE: 1/4"= l'-O" SHEET NUMBER: SCALE: 1/4" = 1'-0" STEEL COL~JNN W/ 2- ~-~/4X9 1/2 ML 6tROER L ~ -0 I~4-X9~ML GIRDER 7'-9" 2XB L~DGER CONNECTED [ GALV. "BOLTS Wi W~SHERMII 28~7 FOUNDATION PLAN SCALE: 1/4" = 1'-0' 3046 K~TC HEN 0 0 0 0 8'-10 1/2" FO YER 29'-$ 0/2" F.6. COLUMN DINING ROOM LIVING ROOM /°% 4'-7" 6' 3 1/2" 3046 3046 3046 3046 1ST. FLOOR PLAN SCALE: 1/4" = 1'-0' LJJ o ~ SHEET NUMBER: A-4 40~ D" MASTER BEDROOM 24'~B 1/2" W I c i W I C BEDRO~OM No. 2 _% BATH 8' 5 I/2" BEDROOM No. 1 2ND. FLOOR PLAN SCALE: 1/4"= 1'-0' m m m LLI o ~ SHEET NUMBER: A-5 EE - ANDARD . I I II1~11 ~ ~ . ~ ~'~ ~ ~1 CO"NEROF HOUSE BUILDING GU~ER AND DR~ELL DETAILS N.T.S. ~ ~PI~L WINDOW OPENING .... ~EKV~R BAR~ ! L~ ~ PER TABLE ~609.1.~, N.Y,S. RES. CODE: ALTERNATIVE FOR OPENING PROTE~ON (IF NOT USING INPA~ G~ING) COVER G~ED OPENINGS WITH A~ACHME~ HARDWA~ PROVIDED. (R~FER TO SE~ON 1609.1.4, 1609.6.5 AND TAB~ 1609.1.4 OF N.*.S. RESIDE~AL *1 .~ I*" m.= .0, I~ ~-~="1 ALLOWABLE HOLES - TJI Joists JOIST DETAILS ~'*' "'" ~ '~ ~'~ ~,....~ s~n= =n= co~u=~ ~n~s n~owns~ .o~s. s~==s an~ .. ......... ................. ' ............................ This sheet is intended asa supplement to the Trus Joist Frame~s Pocket Guide, which should * refere,nced for additional info~ation. WIND LOAD PATH CONNECTION AND CONSTRUCTION DETAIL DRAWINGS FLOORJOISTDEPTHSPNUMBER DESCRipTION ~PLICATION ROOFINGTOAVOIDSO~ING THESpACEVENTILATEO A~OPENINGS ~P CONC. FOUNDA~ON BUlL POLY /, . [ , , , , · , .~ .... -- ~ . ,, OF CONTACT WJTH CONCRE~ OR CONe. BLOCK [ ~A,N TILE fl2,, ~: "~ SHiMS TO LEVEL BEAM WIND LOAD PATH CONNECTION AND CONSTRUCTION DETAIL DRAWINGS RIDGE-TO-RAFTER CONNECTION RAFTER-TO-LEDGER CONNECTION HEADER-TO-POST/STUD CONNECTION RAFTER WALLSTUD RAFTER HANDRAIL CONNECTION CEILING JOIST TO BLDG. CONNECTION pECK/PORCH LEDGER CONNECTION RAFTER TO pLATE/STUD CONNECTION SPLICED JOISTS OVER HEADER/GIRDER WOOD JOIS~ FLUSH JOISTS WITH HEADER/GIRDER SPLICED JOISTS OVER HEADER/GIRDER RAFTER TO PLATE/STUD CONNECTION POST-TO-GIRDER/HEADER CONNECTION H~LLOW COLUMN~ POST-TO-DECK CONNECTION POST-TO-GIRDER/HEADER CONNECTION HEADER/GIRDER-TO-POST CONNECTION pOST DECKPOST FTG. CONNECTION CLIMATIC & GEOGRAPHIC DESIGN CRITERIA DECK AND COVERED PORCH NOTES: NAILING SCHEDULE ROOF SHEATHING: ROOF FRAMING: WALL FRAMING: NAJL NAIL NOTES DECK FRAMING: NAIL NAIL NOTE8 JOINT DESCRIPTION QTy SPACINE JOIST TO 4 - Bd COMMON PER TOE ~ILL~ TOp pLATE OR GIRDER JOIST NAIL BRIDGING 2~ COMMON EACH TOE REVISIONS: o ,¢, t'~ U~ -~ >- A-10 REVISIONS: REVISIONS: ENEFP. AI_ NOTE5 WiNO FRAMING NOTES ROOF FRAMING:II occuP~.C'r CLAS~IFI¢~,TrO~ ~, ~nnectom Steel s~p. shall have ~ m,nimum embedment of 7 ,nche. I. ~ncmte WALL F~MING: .z,~ procedures. 6).The GenemICon,a~.rlstoensure~a[mason~or,mfabm~ed"mplace"maets 5) ~PEI~ERiORSHEARWALLCONNECTIONS STUDTO ~-*~¢COM~O~ ~' I 8).Wlndloedmqu,remen~shal[betekenlnloac~nt"u"n. consl~"Dn, 6) ~pEgE~ERIORSH~RWALLCONNEC~ONS' BO~OMP~TETO, : "~R ~A'L CLIMATIC & GEOGRAPHIC DESIGN CRITERIA FOUNDATION NOTES: mypegex~l~rshe~allsshallmeet~emqa,rementso[tsble3~Sa.b~m~eappmpdate FLOOR JOIST, BAND JOIST, Z-16dCOMMO~ ~ FOOT S~ENO~'%2 lete~lneintendedheghtso flnishedflaor(s)above~pl~lgmde, 7).INTERIORSH~RWALLCONNECTIONS. FLOOR F~MING: LOAD [MPH) CATEGORY DE~H ~MP. REQUIRED H~D8 Ican~/e~rmesen~wa[Iso~ufingln exterlororanheatedJnt~orareas ~) CONNECT~O.SA.OU.O E~"~O"W~O"~'~""S: S,L~r~O..~*~OR~,~ ROOF SHEATHING REQUIREMENTS FOR WIND LOAF ~). Crawl spa~s to be prided wl~ a mlalmum 18"~4" access opening Ins/ail one sAached with ~e ab~ requlmmen~ TO BEAM JOtSTpER TOENAIL N om E S ~.~.~,.~.~.a~,,o..~t~.,.~.~,.,.~ of.,~. DECK AND COVERED PORCH NOTES: I ~o~s~o.,~o~ ~-,~co~uo~ ~o,s~ FRAMING NOTES ~:...,.~.~.,..m~"a~..r~o.,...ho, bo"~'~""~"""u~' ROOF SHEATHING: ,o,~,.,~.mb~-l~<O,~<~<O-~",~.~""",".'",'h""~"""d"~d~"~"c~"~"" W,CU-S,C WALL SHEATHING REQUIREMENTS FOR WIND LOADS: Do.glee Fir I) De:k ~o~s~ to have ~lo~ng at 8'9 ..c,. CEILING SHEATHING: ~.~THING LOCATION AT .~EL EDGES SUPPORTS IN THE PANEL F,ELO openings L~ headem ~ ha~e (3)jack studs and (2) ~ll length studs on each side of WALL SH EATHIN G: NOTES anchom whet apphcab~e te all connecting ]atsts. PLUMBING NOTES 7/16" OSB 6d COMMON 3" O C, EDGE 2),Tabulatedlgln~homnallspaclngassumesshea~lngaUa~edtostud[ramm~m~mbemwith °n plans 2) Ve~ep~lcsystem wi~ ~e Engineer for S~olkCo""~ Heal~ Depa~ment approval' FLOOR SHEA3HING: NOTE: 7) Provide ~loc~lnG/bddglng in floor ~ol~ at S'0 D.C. Use sol~ blocMng In floar ]ais~ NAIL .~ CONT~CTOR TO PROVIDE SOIL TEST TO VE 8).Providetnsula~onbaffiesaleaveven~eenmffem Ins~lldraEblockin~ as s~tecedeand man~acture'srecommen~atlon form~mumholes~zeands~cingp~rmltl~ STRUCTU~LPANEL~ 8dCOMMON 5"O,C, EOGE EXISTING CONDITIONS. MINIMUM 3000~ CAPACI~. ""'""~ HVAC SYSTEM NOTES ~'o~ss 12"0C FIELD 1)~PR~DE5~8~PE~XSHE~R~CKF~REST~PP~NGAT1~M~M~MD~ST~ESF~RN~NAc~ESS~BLEAREAS O O have regular 112" sheeEock. ~l walls [o be [Bped and finished.ELECTRICAL NOTES: ~.~.~ shall be doubled, or alternate ~nne~er~, lav~le. Concealed N~rl~o~[a] rurr~ ep~ee cheil al,o NAIL NAIL NOTES JOINT DESCRIPTION QTY. SPACING NAIL NAIL NOTES JOINT DESCRIPTION QTY SPACING JOIST TO' 4 - fid COMMON PER TOE SILLr TOP PLATE OR GIRDEF JOIST NAIL BRIDGING 2-8d COMMON EACH TOE TO JOIST END NAIL SLOCNING g - ~d COMMON EACH TOE 70 JOIST END NAIL